WorldWideScience
1

Laparoscopic examination of the reproductive organs in women treated for infertility; Laparoskopowa ocena narzadow plciowych u kobiet leczonych z powodu nieplodnosci  

Energy Technology Data Exchange (ETDEWEB)

The authors discuss 84 cases of laparoscopic examination of women with primary or secondary infertility. The patients qualified for this examination had undergone at least 26 weeks of conventional treatment with no effect. In 7 cases the reproductive organ was found to be in order, with fallopian tubes fully patent. In 43 cases tubar inpatency was found (using hysterosalpingographic examination). The remaining patients suffered from other reproductive organ disorders. Therefore, the laparoscopic examination made detailed recognition of the causes of infertility possible and thus helped to establish the proper treatment. Additionally, in some cases it enabled the immediate removal of the source of infertility. (author)

1993-12-31

2

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

3

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

4

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

5

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

6

Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition  

International Nuclear Information System (INIS)

In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse ...

2008-12-01

7

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

8

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) ...

1996-06-01

9

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) ...

10

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...

2005-05-01

11

A heating tube  

Energy Technology Data Exchange (ETDEWEB)

Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.

1980-09-23

12

On the glueball spectrum in O(a)-improved lattice QCD  

CERN Document Server

We calculate the light `glueball' mass spectrum in N_f=2 lattice QCD using a fermion action that is non--perturbatively O(a) improved. We work at lattice spacings a~0.1 fm and with quark masses that range down to about half the strange quark mass. We find the statistical errors to be moderate and under control on relatively small ensembles. We compare our mass spectrum to that of quenched QCD at the same value of a. Whilst the tensor mass is the same (within errors), the scalar mass is significantly lighter in the dynamical lattice theory, by a factor of ~0.84 +/- 0.03. We discuss what the observed m_q dependence of this suppression tells us about the dynamics of glueballs in QCD. We also calculate the masses of flux tubes that wind around the spatial torus, and extract the string tension from these. As we decrease the ...

2002-01-01

13

Fluidelastic instability of heat exchanger tube bundles; Review and design recommendations  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that fluidelastic instability is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross-flow. Most of the available data on this topic have been reviewed from the perspective of the designer. Uniform definitions of critical flow velocity for instability, damping, natural frequency and hydrodynamic mass were used. Nearly 300 data points were assembled. The authors found that only data from experiments where all tubes are free to vibrate are valid form a design point of view. In liquids, fluid damping is important and should be considered in the formulation of fluidelastic instability. From a practical design point of view, we conclude that fluidelastic instability may be expressed simply in term of dimensionless flow velocity and dimensionless mass-damping. There is no advantage in considering more sophisticated models at this time. ...

1991-05-01

14

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial ...

2004-07-01

15

Effective stress of a 4.2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam ...

1993-05-01

16

Effective stress of a 4. 2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A ...

1993-05-01

17

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-15

18

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

International Nuclear Information System (INIS)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-01

19

Hydrodynamics of swirling flow in a circular tube with sudden increase in cross-section and of the flow through a Borda mouthpiece  

Energy Technology Data Exchange (ETDEWEB)

By applying the mass, momentum, and angular momentum conservation laws and the maximum flow rate principle to swirling, effectively inviscid, incompressible flows in a circular tube with a sudden expansion and the direct-flow and reversed-flow Borda mouthpieces the dependence of the flow rate coefficient and mechanical energy losses on the radius ratio and nondimensional circulation is obtained. Several calculating approaches with potential and helical motion are introduced and investigated. In the case of helical motion, as the swirl decreases the axial core of the flow is found to close with a sudden change of the flow parameters.

1994-11-01

20

Relative performance of supercritical binary geothermal power cycles with in-tube condensors in different orientations  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary power plant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in either the horizontal or inclined orientations. ...

1989-01-01

21

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

22

Prediction of refrigerant void fraction in horizontal tubes using probabilistic flow regime maps  

Energy Technology Data Exchange (ETDEWEB)

A state of the art review of two-phase void fraction models in smooth horizontal tubes is provided and a probabilistic two-phase flow regime map void fraction model is developed for refrigerants under condensation, adiabatic, and evaporation conditions in smooth, horizontal tubes. Time fraction information from a generalized probabilistic two-phase flow map is used to provide a physically based weighting of void fraction models for different flow regimes. The present model and void fraction models in the literature are compared to data from multiple sources including R11, R12, R134a, R22, R410A refrigerants, 4.26-9.58 mm diameter tubes, mass fluxes from 70 to 900 kg/m{sup 2} s, and a full quality range. The present model has a mean absolute deviation of 3.5% when compared to the collected database. (author)

2008-04-15

23

Predicting optimum vortex tube performance using a simplified CFD model  

International Nuclear Information System (INIS)

The Ranque-Hilsch tube is a particular type of vortex tube device. The flow enters the device tangentially near one end and exits from the open ends of the tube. The inlet air is of a uniform temperature throughout while the outputs are of different temperatures. One outlet is hotter and the other is colder than the inlet air. This device has no moving parts and does not require any additional power for its operation other than that supplied to the device to compress the inlet air. It has, however, not been widely used, mainly because of its low efficiency. In this paper, a simplified 2-dimensional computational fluid dynamics model for the flow in the vortex tube is developed using FLUENT. This model makes use of the assumption of axial symmetry throughout the entire flow domain. Compared to a three-dimensional computational solution, the simplified model requires significantly less computational time. ...

2004-05-09

24

A review of heat exchanger tube bundle vibrations in two-phase cross-flow  

International Nuclear Information System (INIS)

Flow-induced vibration is an important concern to the designers of heat exchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heat exchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heat exchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase mixture and involves an important consideration, which is the void ...

2004-05-01

25

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling ...

2005-07-01

26

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided ...

2005-03-17

27

Plasma chemistry in wire chambers  

Energy Technology Data Exchange (ETDEWEB)

The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing ...

1990-05-01

28

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance ...

2002-07-01

29

Modelling of two-phase natural circulation in a WWER-plant: PMK experimental results  

International Nuclear Information System (INIS)

Experiments have been performed with the PMK integral-type facility, a model of WWER-440 type PWRs, to investigate two-phase natural circulation behaviour. The phenomena to be expected in this reactor type are different from those in PWRs with vertical steam generators mainly due to the loop seal in the hot leg and the horizontal layout of the steam generator heat transfer tubes. The experiments showed that the system is repressurized when the water level drops to the hot leg elevation due to the effect of the loop seal. Opening of the loop seal can be smooth, but may lead to oscillations depending on the power and the mass inventory. Natural circulation recovers after the hot leg loop seal is opened, but then decreases with further mass inventory decrease. (orig.).

30

Hydrodynamics induced vibration to trash-racks  

International Nuclear Information System (INIS)

In conventional power plants trash-racks are provided at the intakes to protect the turbines. In pumped storage plants, the draft tube or tailrace must also have trash-racks to protect the units while pumping. Because the loads believed to cause many failures of trash-racks are dynamic in nature, it is important to understand the dynamic characteristics of trash-racks structures in general and a single rack in particular. The classical added-mass solution structure-fluid dynamic interaction is known as an approximate solution procedure. An accurate added-mass approach mixed with implementation in finite element framework is proposed. In this proposal, experimental conclusions, supported by theory, led to presentation of more accurate results in vibration of trash-racks. This numerical solution as a powerful method to solve such a complex problem can be employed to carry out dynamic characteristics of these structures while ...

2002-12-01

31

Neutrino masses in the MSSM  

CERN Document Server

Neutrino masses in the MSSM

2007-01-01

32

The influence of gas on the structure of disk merger remnants  

CERN Document Server

We present a large set of merger simulations of early-type disc galaxies with mass ratios of 1:1 and 3:1 and 10% of the total disc mass in gas. In contrast to the collisionless case equal-mass mergers with gas do not result in very boxy remnants which is caused by the suppression of box orbits and the change of the projected shape of minor-axis tube orbits in the more axisymmetric remnants. The isophotal shape of 3:1 remnants and the global kinematic properties of 1:1 and 3:1 remnants are only weakly affected by the presence of gas. 1:1 remnants are slowly rotating whereas 3:1 remnants are fast rotating and discy. The shape of the stellar LOSVD is strongly influenced by gas. The LOSVDs of collisionless remnants have broad leading wings while their gaseous counterparts show steep leading wings, more consistent with observations of elliptical galaxies. We show that this change is also caused by the ...

2006-01-01

33

Forced and mixed convection heat transfer to supercritical CO{sub 2} vertically flowing in a uniformly-heated circular tube  

Science.gov (United States)

An experiment of heat transfer to CO{sub 2}, which flows upward and downward in a circular tube with an inner diameter of 6.32 mm, was carried out with mass flux of 285-1200 kg/m{sup 2} s and heat flux of 30-170 kW/m{sup 2} at pressures of 7.75 and 8.12 MPa, respectively. The corresponding Reynolds number at the tube test section inlet ranges from 1.8 x 10{sup 4} to 3.8 x 10{sup 5}. The tube inner diameter corresponds to the equivalent hydraulic diameter of the fuel assembly sub-channel, which is being studied at KAERI. Among the tested correlations, the Bishop correlation predicted the experimental data most accurately, but only 66.9% of normal heat transfer data were predicted within {+-}30% error range. The Watts and Chou correlation, which is claimed to be valid for both the normal and deteriorated heat transfer regime, showed unsatisfactory performance. A significant decrease in Nusselt number was ...

2010-11-15

34

Flow patterns and heat transfer coefficients in flow-boiling and convective condensation of R22 inside a micro fin of new design  

International Nuclear Information System (INIS)

Saturated flow boiling and convective condensation experiments for oil-free refrigerant R22 been carried out with a micro fin tube of new design and with a smooth tube. Both tube have the same outer diameter of 9.52 mm and are horizontally operated. Two-phase flow pattern data have been obtained in addition of heat transfer coefficient and pressure drops; more-over, adiabatic tests have been also performed in order for flow pattern map to cover even adiabatic flows. Data are for mass fluxes ranging from about 90 to 400 Kg/s m"2. In boiling tests, the nominal saturation temperature is 5 degree C, with inlet quality varying from 0.2 to 0.6 and the quality change ranging from 0.1 to 0.5. In condensation, results are for saturation temperature equal to 35 degree C, with inlet quality between 0.8 and 0.4, and quality change within 0.6 and 0.2. The comparison shows a large heat transfer augmentation with a ...

1998-01-01

35

Two-stage solar multi-effect humidification dehumidification desalination process plotted from pinch analysis  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a two-stage solar multi-effect humidification dehumidification desalination process plotted from pinch analysis. The sketch of two-stage solar multi-effect humidification dehumidification desalination process is given. The solar vacuated tube collector is employed in the desalination system, multi-effect humidification dehumidification desalination (HDD) process are plotted two different temperature range according to pinch technology. The higher temperature range is from 60 to 80?C, and the lower is from 30 to 60?C. The mass flow rates of dry air in the two stage desalination units are different. The pinch analysis chart is given. According to the pinch chart, the energy recover rate could get higher according to working temperature range. The research proves that the ...

2008-01-01

36

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

37

STATUS OF THE DIELECTRIC WALL ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

2009-04-22

38

Random walk function in the analysis of time-activity curves from dynamic radionuclide studies  

Energy Technology Data Exchange (ETDEWEB)

The random walk function is a mathematical function derived from studies of the mass transport and flow of diffusible materials through tubes. Approximations to the function were first used some time ago in the field of cardiac tracer dilution curves, but in the absence of rapid and reproducible curve fitting the method never became commonplace. The current study uses the latest curve-fitting techniques and shows how the method may be used with precision in the analysis of time-activity curves from dynamic oesophageal and blood flow studies. The physiological basis of the method is given and parameters obtained which relate to both the rate of flow and the local dispersion of the bolus.

1987-04-01

39

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

40

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

41

Tests of Turbulators for Fire-Tube Boilers.  

Science.gov (United States)

... Originator-supplied keywords include: Turbulators, Heat transfer augmentation, Enhancement, Fire tube boilers. (Author). ...

1982-10-01

42

ELECTRON ATTACHMENT OF SEF6  

Science.gov (United States)

... attachment tube which is sketched in Fig. 1. It is mounted inside a cylindrical evacuated tube. A beam of thermal electrons ...

1961-06-20

43

Diaphragm Rupture Effects on an Expanding Flow in a Tube.  

Science.gov (United States)

... The fundamental problem of diaphragm rupture was studied experimentally to determine the effects on an expanding flow in an evacuated tube. ...

1972-08-01

44

Steam generator tube denting-criteria for tube plugging  

International Nuclear Information System (INIS)

When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.

45

State-of-the-art technology for production of seamless tubes in zirconium and titanium alloys  

International Nuclear Information System (INIS)

Zircaloy fabrication plant manufactures all the necessary Zr-2 components like fuel canning tubes, calandria tubes and other rod and sheet products. This plant is having a capacity of producing about 4 lakh nos. of PHWR fuel tubes per annum. These tubes are seamless, thin walled with close dimensional tolerances and stringent mechanical properties. The plant has established all the facilities required to produce these tubes with required quality.

46

Relative correlation of Jet-REMPI monitoring with adsorption tube sampling followed by TDS-CIS-GC/MS  

Energy Technology Data Exchange (ETDEWEB)

During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. However, due to ...

2004-09-15

47

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

Science.gov (United States)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been ...

2002-07-01

48

Horizontal Steam Generator Thermal-Hydraulics at Various Steady-State Power Levels  

International Nuclear Information System (INIS)

Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take ...

2002-04-14

49

Mass transfer model for two-layer TBP oxidation reactions  

Energy Technology Data Exchange (ETDEWEB)

To prove that two-layer, TBP-nitric acid mixtures can be safely stored in the canyon evaporators, it must be demonstrated that a runaway reaction between TBP and nitric acid will not occur. Previous bench-scale experiments showed that, at typical evaporator temperatures, this reaction is endothermic and therefore cannot run away, due to the loss of heat from evaporation of water in the organic layer. However, the reaction would be exothermic and could run away if the small amount of water in the organic layer evaporates before the nitric acid in this layer is consumed by the reaction. Provided that there is enough water in the aqueous layer, this would occur if the organic layer is sufficiently thick so that the rate of loss of water by evaporation exceeds the rate of replenishment due to mixing with the aqueous layer. This report presents measurements of mass transfer rates for the mixing of water and butanol in two-layer, TBP-aqueous mixtures, where the top layer ...

1994-09-28

50

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube ...

1983-04-26

52

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

53

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a cylindrical configuration, and a similar flow ...

1346-01-01

54

A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography  

International Nuclear Information System (INIS)

Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast phantom and ...

1999-11-01

55

The Rab GTPase RabA4d Regulates Pollen Tube Tip Growth in Arabidopsis thaliana[W  

UK PubMed Central (United Kingdom)

During reproduction in flowering plants, pollen grains form a tube that grows in a polarized fashion through the female tissues to eventually fertilize the egg cell. These highly polarized pollen tubes...Full Text Available

2009-02-01

56

The Experimental Determination of the Thermodynamic and Hydrodynamic Mechanism of Augmented Flow Boiling in Tubes.  

Science.gov (United States)

Experimental results are presented for a new and unique heat transfer augmentation technique in tubes. The technique consists of inserting a porous mesh structure into the flow passage of the tube. Due to the increased degree of turbulence, both the singl...

1970-01-01

57

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

58

Secondary side concept to prevent steam generator tube corrosion  

International Nuclear Information System (INIS)

Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.

1989-05-01

59

Large-scale absolute dent evaluation campaign  

International Nuclear Information System (INIS)

Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).

60

Graphitic nano tubes and aligned nano tubes films  

Energy Technology Data Exchange (ETDEWEB)

Carbon nano tubes are easily produced in macroscopic quantities, however their characterisation and possible applications are still rather limited. We have developed a new method to make aligned nano tube films which open new opportunities, not only for basic research but also for eventual applications. With this method the tubes can be aligned either parallel or perpendicular to the surface. We give a short review of the microscopic properties of single tubes and the bulk properties of the aligned films. (author). 24 refs., 6 figs.

1996-03-01

61

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

62

Thoracoscopy in Children: Is a Chest Tube Necessary?  

UK PubMed Central (United Kingdom)

PurposeHistorically, a chest tube or drain has been left following a thoracic operation to allow drainage of air or fluid in the postoperative period. However, in...Full Text Available

2009-04-01

63

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters  

Science.gov (United States)

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters

1987-03-01

64

Development of technology on the material surveillance of CANDU pressure tubes  

International Nuclear Information System (INIS)

Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test ...

1997-05-21

65

Description of the ER-2 Dropwindsonde System The ... - ESPO - NASA  

Science.gov (United States)

2 illustrates the design of the launch tube, the gun barrel design of the multi-tube dispenser and integrated hardware pressure cannister. ...

66

An Optical Fiber Infrasound Sensor  

Science.gov (United States)

... We use a compliant, sealed tube helically wrapped with an optical fiber. ... 2.5 cm diameter compliant, sealed tube 10 m < length < 120 m ...

2000-09-01

67

Materials considerations for the National Spallation Neutron Source target  

Energy Technology Data Exchange (ETDEWEB)

The National Spallation Neutron Source (NSNS), in which neutrons are generated by bombarding a liquid mercury target with 1 GeV protons, will place extraordinary demands on materials performance. The target structural material will operate in an aggressive environment, subject to intense fluxes of high energy protons, neutrons, and other particles, while exposed to liquid mercury and to water. Components that require special consideration include the Hg liquid target container and protective shroud, beam windows, support structures, moderator containers, and beam tubes. In response to these demands a materials R and D program has been developed for the NSNS that includes: selection of materials; calculations of radiation damage; irradiations, post irradiation testing, and characterization; compatibility testing and characterization; design and implementation of a plan for monitoring of materials performance in service; and materials engineering and technical ...

1997-08-01

68

Investigation of Heat Transfer in Supercritical Fluids for Application to the Generation IV  

Energy Technology Data Exchange (ETDEWEB)

Using a facility named SPHINX, which can accommodate a heat transfer test with CO{sub 2} at supercritical pressure, a series of tests was performed. The test geometries include tubes with the inner diameter of 4.4, 6.32 and 9 mm. a concentric annular passages with 8 x 10 mm, and an eccentric annular passages with 9.5 x 12.5 mm. Based on the test results, heat transfer correlations were developed and compared with the existing correlations. The heat transfer deterioration which may occur at certain conditions of heat and mass flux, were carefully studied and the published criteria were reviewed against our test results. Numerical calculation by using commercial CFD code, Fluent, were performed in order to provide the pre-test information for the heat transfer tests. Various turbulence models were evaluated and reliable models were suggested for each case

2007-08-15

69

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m ...

2003-06-01

70

Experiments with the HORUS-II test facility  

Energy Technology Data Exchange (ETDEWEB)

Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as accident simulation tests ...

1997-12-31

71

Condensation driven water hammer studies for feed water distribution pipe  

International Nuclear Information System (INIS)

Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of the order of few minutes. (M.D.).

1997-05-26

72

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. ...

2009-06-17

73

Challenges in fabrication of 180deg magnet chamber  

International Nuclear Information System (INIS)

180 deg magnet chamber is used in Folded Tandem Ion Accelerator for passage and 180 deg bending of ion beam. The chamber is placed between 180 deg terminal magnet (Electro-magnet), which is used for bending, and analysing the beams. Magnet with a particular magnetic field strength bends ions of only specified mass energy product through a precise path. There is also a space limitation in the direction of magnetic field. Both of them require the magnet chamber to be of a close tolerance. Accuracy of center distance between inlet and outlet port of the magnet chamber has to be at par with the concentricity of high energy and low energy beam line. To achieve this we started the fabrication of magnet chamber by following two methods: a) Circular rolling and bending of rectangular tube for 180 deg sector of magnet chamber b) Machining 180 deg sector in two half and welding. By first method we could not achieve the desired result although the method ...

2006-11-01

74

Boiling heat transfer in a small horizontal rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Compact heat exchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heat exchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heat exchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 mm) using refrigerant 12 (R-12). As with the circular tube studies, the flow channel wall was electrically heated providing a constant heat flux. ...

1993-08-01

75

A study of Two-Phase Flow Regime Maps in Vertical and Horizontal Pipes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of flow regime transition regions. Conclusively, the process will be ...

2007-10-15

76

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical model of simultaneous ...

1985-10-01

77

A hydroxide mixture as working fluid for absorption heat pumps  

Energy Technology Data Exchange (ETDEWEB)

Basic experimental investigations were carried out with an aqueous solution of a mixture of KOH and NaOH for use as an absorbent in absorption heat pumps. Due to its thermophysical properties this mixture allows temperature lifts from evaporator to absorber of more than 75 K (135 F) in a single-stage absorption chiller. Thermophysical and hydrodynamical properties of the solution were measured. Vapor-liquid-equilibrium data and specific heat capacities were determined for concentrations ranging from 35% up to 75% and temperatures up to 200 C (392 F). From these data the enthalpy of the solution was calculated. Additionally the crystallization temperatures, the density, and the viscosity of the solution were determined. The experimental equipment is described. The data are presented as polynomials and diagrams including experimental accuracy. An apparatus was constructed to measure heat and mass transfer coefficients of the absorption process with this solution. The ...

1996-11-01

78

A calculation model for thermo-hydraulic analyses of the PGV-1000 steam generator  

International Nuclear Information System (INIS)

A calculation model was developed for the analysis of thermal and hydraulic processes in the PGV-1000 horizontal steam generator. The model makes it possible to examine the hydraulics of the primary medium, i.e., the distribution of flow velocities and mass flows in the exchanger tube system and hydraulic losses of the primary medium in the steam generator during its flow between the two connecting sites to the main circulation pipeline, spatial distribution of heat fluxes between the primary and secondary sides of the steam generator and the total transmitted thermal power, pressure on the secondary side of the generator, natural circulation of the working medium on the secondary side, and the mean circulation number, spatial distribution of the volume fraction of the steam component in the intertubular space, effect of the perforated sheet on the thermo-hydraulic processes in the steam generator, redistribution of the steam component in the ...

1994-01-01

79

Thermal energy storage performance of fatty acids as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

Thermal energy storage performance of fatty acids and a eutectic mixture as phase change materials (PCMs) has been investigated experimentally. The selected PCMs for this study were palmitic acid, myristic acid, stearic acid, and a mixture of stearic and myristic acids in eutectic combination ratio of 65.7 wt% myristic acid and 34.3 wt% stearic acid. The PCMs have a melting temperature range of 50.0{sup o}C to 61.20{sup o}C and a latent heat range of 162.0 J/g to 204.5 J/g. The inlet temperature and the mass flow rate of heat transfer fluid (HTF) were selected as experimental parameters to test the thermal energy storage performance of the PCMs. The transition times, temperature range, propagation of the solid-liquid interface, as well as heat flow rate characteristics of the employed cylindrical tube storage system were studied at varied experimental parameters. The experimental results show that the melting front moves to inward in the radial ...

2006-01-21

80

Study of the effect of noncondensable gas on heat transfer phenomena in horizontal steam generator of pactel facility with CATHARE2 V1.5a  

International Nuclear Information System (INIS)

Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and calculated (CATHARE code version V15a mod 2.1) results of the test NCg-l. It was carried out in natural ...

2001-03-20

81

SGTR Project: Separate Effect Studies for Vertical Steam Generators  

Energy Technology Data Exchange (ETDEWEB)

The SGTR project has been carried out within the fifth EURATOM Framework Programme (Contract No FIKS-CT-1999-0007). Its main objective was to provide an experimental database and to develop and/or verify models to support definition of accident management measures in the hypothetical case of a Steam Generator tube Rupture (SGTR) sequence. The project addressed both vertical and horizontal steam generator designs. This report summarises the main results obtained in the intermediate scale experimentation that addressed Western type steam generators. The specific goal of this test programme was to investigate aerosol retention in the break stage of the secondary side of a water-empty steam generator. The test matrix consisted of 12 tests that explored the influence of variables such as break type and orientation and inlet gas flow rate. This work was performed in the PECA facility of the Laboratory for Analysis of Safety Systems (LASS). Aerosol retention at the break ...

2003-07-01

82

Quantifying the Reactive Uptake of OH by Organic Aerosols in aContinuous Flow Stirred Tank Reactor  

Energy Technology Data Exchange (ETDEWEB)

Here we report a new method for measuring the heterogeneous chemistry of submicron organic aerosol particles using a continuous flow stirred tank reactor. This approach is designed to quantify the real time heterogeneous kinetics, using a relative rate method, under conditions of low oxidant concentration and long reaction times that more closely mimic the real atmosphere. A general analytical expression, which couples the aerosol chemistry with the flow dynamics in the chamber is developed and applied to the heterogeneous oxidation of squalane particles by hydroxyl radicals (OH) in the presence of O2. The particle phase reaction is monitored via photoionization aerosol mass spectrometry and yields a reactive uptake coefficient of 0.51+-0.10, using OH concentrations of 1-7x108 molec cdot cm-3 and reaction times of 1.5+-3 hours. This uptake coefficient is larger than that found for the reaction carried out under high OH concentrations (~;;1x1010 molec cdot cm-3) and ...

2009-03-01

83

Numerical study on the heat transfer to CO_2 flowing upward in a heated vertical tube at supercritical pressure  

International Nuclear Information System (INIS)

Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be obtained with this fluid, and (ii) some existing facilities already used surrogate fluids, which in general have lower critical pressure and ...

2005-10-02

84

Cracking of Alloy 800 tubing in superheated steam in a solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the ...

1985-10-01

85

Wolsung-1 NPP - electrictal systems  

International Nuclear Information System (INIS)

... power reactors pressure tube reactors reactors THERMAL REACTORS.

1980-06-18

88

Experimental investigation for fluid flow and heat transfer in a rotating tube with twisted-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.

1995-04-01

90

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

91

Two-phase flow patterns and frictional pressure gradients in a small, horizontal, rectangular channel  

Energy Technology Data Exchange (ETDEWEB)

Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heat exchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic data, was used to develop a flow pattern man. A comparison of existing flow pattern maps for circular pipes, capillary tubes, ...

1990-05-01

92

Tube bundle for a heat exchanger  

International Nuclear Information System (INIS)

The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.

93

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

94

Control Rod Ejection Accident while Using 6- and 8-Tube IRT-4M Fuel Assemblies in WWR-SM Research Reactor Core  

Energy Technology Data Exchange (ETDEWEB)

The WWR-SM reactor at the Institute of Nuclear Physics of the Academy of Sciences (INP AS) in Uzbekistan was converted to 6-tube IRT-4M LEU (19.7%) fuel in 2009. Presently, INP intends to also use IRT-4M 8-tube FA, and a safety analysis for these 'mixed' (8-tube and 6-tube FA) cores is required by the regulatory authorities. This paper presents results of control rod ejection transient analysis for these mixed cores

2011-07-01

95

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

96

A Bragg curve ionization chamber for acceleration mass spectrometry  

CERN Document Server

A Bragg curve ionization chamber for acceleration mass spectrometry

1985-01-01

97

Simulation of sludge deposit onto a 900 MW steam generator tubesheet with the 3D code GENEPI  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer processes use fluids which are generally not pure and can react with transfer surfaces. These surfaces are subject to deposits which can be sediments harmful to heat transfer and to integrity of materials. For nuclear plant steam generators, sludge build-up accelerates secondary side corrosion by concentrating chemical species. A major safety problem involved with such a corrosion is the growing of circumferential cracks which are very difficult to detect and size with eddy current probes. With a view to understand and control this problem, it is necessary to develop a mathematical model for the prediction of sludge behavior in PWR steam generators. Based on fundamental principles, this work intends to use different models available in literature for the prediction of the phenomenon leading to the accumulation of sludge particles at the bottom (the tubesheet) of a PWR. For that, a three-dimensional simulation of magnetite particulate fouling with the finite elements code ...

1998-07-01

98

Operating experience with Alloy 800 SG tubing in Europe  

Energy Technology Data Exchange (ETDEWEB)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. ...

2007-07-01

99

Operating experience with Alloy 800 SG tubing in Europe  

International Nuclear Information System (INIS)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. These indications ...

2007-08-19

100

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected ...

2000-10-01

101

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

102

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

103

Research on corrosion resistance of steam generator tube  

International Nuclear Information System (INIS)

In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).

104

Preparation of reactor tube by welding a porous membrane with a non-porous ceramic tube  

Energy Technology Data Exchange (ETDEWEB)

In the course of designing a catalytic porous membrane reactor for experimental studies, both inside and outside of the non-reaction zones as well as the two ends of the membrane need to be completely sealed to ensure that there is no flow across the membrane in the non-reaction zone. Experiments show that up to 50% of the total flow across the membrane may be contributed by the axial flow along the wall of the non-reaction zones if only one side of the membrane is sealed. Another problem that cannot be solved by sealing is the capillary flow of the catalyst along the tube wall into the non-reaction zones when the catalyst is doped on the membrane. One of the best ways to avoid this axial flow of catalyst would be to use non-porous tubes in the non-reaction zones and join them with the porous membrane tube. In doing so, the cost of the membrane reactor could be reduced simply because shorter membrane ...

1994-12-31

105

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with ...

2003-05-28

106

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

Energy Technology Data Exchange (ETDEWEB)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-01-01

107

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

International Nuclear Information System (INIS)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-03-09

108

Alloy 800 welding experience at UKAEA Springfields  

International Nuclear Information System (INIS)

Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heat exchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube to ...

109

Low-Cost Hydrogen Distributed Production System Development  

Science.gov (United States)

H{sub 2}Gen, with the support of the Department of Energy, successfully designed, built and field-tested two steam methane reformers with 578 kg/day capacity, which has now become a standard commercial product serving customers in the specialty metals and PV manufacturing businesses. We demonstrated that this reformer/PSA system, when combined with compression, storage and dispensing (CSD) equipment could produce hydrogen that is already cost-competitive with gasoline per mile driven in a conventional (non-hybrid) vehicle. We further showed that mass producing this 578 kg/day system in quantities of just 100 units would reduce hydrogen cost per mile approximately 13% below the cost of untaxed gasoline per mile used in a hybrid electric vehicle. If mass produced in quantities of 500 units, hydrogen cost per mile in a FCEV would be 20% below the cost of untaxed gasoline in an HEV in the 2015-2020 time period using EIA fuel cost projections for ...

2011-03-10

110

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

British Library Electronic Table of Contents (United Kingdom)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-01-01

111

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

Science.gov (United States)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-12-01

112

Terminated Exploding Wire Energy Source.  

Science.gov (United States)

By placing a discharge or 'dump' tube across an exploding bridgewire load, it is possible to by-pass the electrical energy and terminate the explosion of the wire. The dump tube is triggered by a signal derived from the energy removed from the storage cap...

1965-01-01

113

Stability of Plasma Human Immunodeficiency Virus Load in VACUTAINER PPT Plasma Preparation Tubes during Overnight Shipment  

UK PubMed Central (United Kingdom)

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available

2000-01-01

114

Social media - Social media, The University of York  

Wastenet

...A directory of University social media accounts, including Facebook, Twitter and YouTube facebook, twitter, blog Social media - Social media, The ... Key: Facebook, Twitter, YouTube, Blog, LinkedIn, Flickr Missed you out? If you'd like to be included on this ...

115

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

116

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...

1979-01-01

117

Multiple neural tube defects in the same patient with no neurological deficit  

UK PubMed Central (United Kingdom)

Congenital deformities involving the coverings of the nervous system are called neural tube defects (NTDs). NTD can be classified as neurulation defects, which occur by stage 12, and postneurulation...Full Text Available

2010-01-01

118

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

119

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process ...

2010-07-01

120

Lectin Binding of the Major Polar Tube Protein (PTP1) and its Role in Invasion  

Science.gov (United States)

... 2003)050[0600:LBOTMP]2.0.CO;2 Lectin Binding of the Major Polar Tube Protein (PTP1) ... PTP1. We, therefore, undertook a study ...

121

Intergranular attack or corrosion in a once-through model steam generator: Final report  

Energy Technology Data Exchange (ETDEWEB)

Faulting the feedwater for a 19-tube, model steam generator with 10 ppM of caustic once a week produced widespread shallow 25 to 75 micrometers (1 to 3 mils) intergranular attack (IGA) on alloy 600 tubes and an axial tube rupture at the steam-water interface after 4.8 years. An extensive investigation of the IGA damage found little correlation with major test variables beyond the indication that mill-annealed tubing was more susceptible to attack than stress-relieved tubing. The most likely cause of the tube rupture was caustic that concentrated to high levels in a porous scale on the tube at the liquid-vapor interface where there was a high available superheat. Nondestructive examination (NDE) eddy current probes underestimated the depth of IGA and were not sensitive to circumferential cracks less than 152 micrometers (6 mils) deep that ...

1987-07-01

122

Integrity of the tubes used in vertical and horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Statistical data on experience gained from operation of steam generators around the world are presented, problems arising in vertical and horizontal steam generators are described, and the conditions of heattransfer tubes used in them are compared.

2011-01-01

123

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between ...

1976-03-09

124

Enhanced tube inner surface heat transfer device and method  

Science.gov (United States)

An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.

1979-05-15

125

Endoscopic T-tube placement in the management of lye-induced esophageal perforation: Case report of a safe treatment strategy  

UK PubMed Central (United Kingdom)

Esophageal perforation is associated with a significant risk of morbidity and mortality. We report herein a case of lye-induced esophageal perforation managed successfully by employing endoscopic T-tube...Full Text Available

126

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the ...

1995-08-01

127

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...

128

An argument for the conservative management of small traumatic pneumathoraces in populations with high prevalence of HIV and tuberculosis: an evidence-based review of the literature  

UK PubMed Central (United Kingdom)

BackgroundTraumatic pneumothoraces are common. Many are managed with tube thoracostomy. However, there is a high complication rate from chest tube placement, particularly in patients...Full Text Available

129

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

130

Peripherally inserted central catheter  

Science.gov (United States)

You have a peripherally inserted central catheter (PICC). This is a tube that goes into a vein in your arm. It will help carry nutrients ...

131

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

132

Kinetics of salt concentration in heated crevices  

International Nuclear Information System (INIS)

In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.

1985-03-01

133

Is OD peening of Alloy 800 SG tubes desirable?  

Energy Technology Data Exchange (ETDEWEB)

The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.

1992-12-31

134
135

Heat exchanger tube vibration: comparison between operating experiences and vibration analyses  

International Nuclear Information System (INIS)

Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).

1992-12-01

137

Explosive Performance Modification by Cosolidification of ...  

Science.gov (United States)

... A booster pellet, normally Comp B, was placed in the tube and an exploding bridgewire (EBW) detonator in a plastic holder was glued in with a ...

1976-10-01

139

Dictionary of Technical Terms for Aerospace Use - S  

Science.gov (United States)

sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...

140

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

141

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

142

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

143

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

144

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

145

Solar collectors with tubes partially filled with porous substrates  

Energy Technology Data Exchange (ETDEWEB)

In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.

1999-02-01

146

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

147

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

Energy Technology Data Exchange (ETDEWEB)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-07-01

148

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

International Nuclear Information System (INIS)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-10-27

149

Characterization of tube support alloys  

International Nuclear Information System (INIS)

The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.

1985-03-01

150

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

151

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

152

Centering device  

Energy Technology Data Exchange (ETDEWEB)

A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.

1980-03-15

153

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in ...

2001-01-15

157

Study of the action of a phosphonate additive on steel scale deposit and corrosion in the hydrodynamic conditions of a channel flow cell; Etude de l'action d'un additif phosphone sur l'entartrage et sur la corrosion de l'acier dans les conditions hydrodynamiques d'une cellule a canal  

Energy Technology Data Exchange (ETDEWEB)

In cooling systems, an improved control of scale deposit and corrosion processes is a major challenge and an realistic evaluation tool for water treatments is of the utmost economic importance. In this study, a channel flow cell was used to allow in-situ electrochemical measurements in well defined electrolyte tube flowing conditions. An expression of the mass transfer towards the electrode was established where the diffusion-limited current is a function of Re{sup 1/3} in the laminar regime and was verified experimentally using the redox couples Fe[CN]{sub 6}{sup 4-}/ Fe[CN]{sub 6}{sup 3-} and O{sub 2}/OH{sup -}. This hydrodynamically controlled experimental device was developed to investigate scale deposit processes and to evaluate scale inhibitor efficiency using a electrochemical quartz crystal microbalance. Experiments were performed on three different waters, at various flow rates and temperatures. The efficiency of a well known ...

2000-10-17

158

Post-CHF Heat Transfer characteristics in one rod bundle geometry  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m{sup 2}s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in heat exchangers operating ...

2006-07-01

159

Post-CHF Heat Transfer characteristics in one rod bundle geometry  

International Nuclear Information System (INIS)

In the present paper, experimental study of forced convection boiling were performed to investigate the post-CHF characteristics of a vertical annular channel with one heated rod and four spacer grids for new refrigerant R-134a. The experiments were conducted under outlet pressure of 11.6, 13, 16 and 20 bar, mass fluxes of 100-600 kg/m2s, and inlet temperatures of 25-51 .deg. C. The parametric trend of the post-CHF data was well consistent with previous studies. The two phase flow regime in tube flow occurring downstream of the CHF has been called post-CHF, dispersed flow, liquid-deficient flow, mist flow and film boiling. This regime is characterized by a continuous vapor phase with discrete liquid drops and a non-wetted heated surface. This regime has a considerable importance in the areas of light water reactor(LWR) accident analysis and other film boiling applications. The post-CHF region occurs by design in heat exchangers operating in the ...

2006-11-02

160

Boiling heat transfer in compact heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation pressure was nearly constant, averaging 0.82 MPa for most of the ...

1994-12-31

161

Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations  

Energy Technology Data Exchange (ETDEWEB)

The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.

2008-11-12

162

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-15

163

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-01

164

Superphenix 1 steam generator fabrication  

Energy Technology Data Exchange (ETDEWEB)

The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heat exchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for ...

1985-02-01

165

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

166

Investigations on denting phenomenon in monel tubes  

International Nuclear Information System (INIS)

Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 300"0C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author).

1981-05-01

167

Evaluation, testing and database generation of pitting corrosion characteristics of domestic steam generator tubing material  

Energy Technology Data Exchange (ETDEWEB)

Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)

1998-04-01

168

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-07-01

169

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-06-01

170

Top of tubesheet cracking in Bruce A NGS steam generator tubing - recent experience  

Energy Technology Data Exchange (ETDEWEB)

During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary ...

1998-07-01

171

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-07-01

172

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

International Nuclear Information System (INIS)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-10-27

173

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator ...

1996-06-01

174

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. ...

2010-10-01

175

Failure analysis report: Heat exchanger tubes geothermal binary power plant, Magma Electric Company, East Mesa, California  

Energy Technology Data Exchange (ETDEWEB)

Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.

1982-05-01

176

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...

2011-01-15

177

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

Energy Technology Data Exchange (ETDEWEB)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

1987-07-01

178

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

International Nuclear Information System (INIS)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

179

Sustainable water resources management in Pakistan  

International Nuclear Information System (INIS)

Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On the Environmental Front the main problems are water-logging ...

2004-06-07

180

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological ...

181

SOME RECENT DETERMINATIONS OF ATOMIC MASSES IN THE STRONTIUM-ZIRCONIUM REGION  

Science.gov (United States)

A large double-focusing mass spectrometer was used to obtain new values for the masses of Sr/sup 86/, Sr/sup 88/, and Zr/sup 90/. Mass differences calculated from these values are found to be in better agreement with nuclear transmutation information than were previous mass spectroscopically derived values. (auth)

1960-06-01

182

Evolution of the chromospheres and winds of low- and intermediate-mass giant stars  

International Nuclear Information System (INIS)

Results are presented of an empirical analysis of the global thermodynamical requirements of the winds in the outer atmospheres of a representative sample of red giant stars of low- and intermediate-mass range. Results indicate that the mass-loss rates in these stars are not strongly dependent on the actual physical processes driving the winds. It is suggested that nonlinear processes act to regulate wind energy fluxes. Possible mechanisms responsible for the chromospheric heating and the mass loss in the low- and intermediate-mass giant stars are discussed. 151 refs.

183

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical ...

2002-03-01

184

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-11-16

185

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-07-01

186

Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)  

International Nuclear Information System (INIS)

Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds number of 2.9 x 10"3 to ...

1978-01-01

187

NPP steam generator: materials and water-chemical regime  

International Nuclear Information System (INIS)

The main reasons of tube failures in steam generators (SG) are considered. 1.Stress corrosion craining which has 28% of SG (most of them have stainless steel tubes). 2. Corrosion loss of metal, which accounts for 24% of tubes (phosphate corrosion due to addition of PO into water). 3.Denting-peripheral pressing of tubes in the openings of the foundation plates by the corrosive products, which are formed on internal surface of drillings in the foundation plates made of carbon steel. 4.Separation of a plating layer on tube panels. 5.Dratting-corrosion. 6.Metal fatigue. A series of experiments were conducted to study the influence of material selection on tube reliability (stainless steel 304, inconel-600, mone-400, incalloy-800). The problem of increase of SG elements reliability is a complex one and can be solved by direct selection of material, proper control of ...

188

FRAMATOME's continuous efforts to improve steam generator corrosion resistance  

International Nuclear Information System (INIS)

Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam generator models, including a large number ...

189

Experimental verification of the horizontal steam generator boil-off transfer degradation at natural circulation  

Energy Technology Data Exchange (ETDEWEB)

The presentation summarises the highlights of experimental results obtained for VVER type horizontal steam generator heat transfer, primary side flow pattern, and mixing in the hot collector during secondary side boil-off with primary at single-phase natural circulation. The experiments were performed using the PACTEL facility with Large Diameter (LD) steam generator models, with collector instrumentation designed specifically for these tests. The key findings are as follows: (1) the primary to secondary heat transfer degrades as the secondary water inventory is depleted, following closely the wetted tube area; (2) a circulatory flow pattern exists in the tube bundle, resulting in reversed flow (from cold to the hot collector) in the lower part of the tube bundle, and continuous flow through the upper part, including the tubes that have already dried out; and (3) mixing of the hot leg flow entering the ...

1997-12-31

190

Experimental Evaluation of Tude Support Plate Crevice Chemistry  

Energy Technology Data Exchange (ETDEWEB)

A test methodology for measuring temperature, impedance, pH, and electrochemical potential distributions within a sludge-packed tube support plate crevice in a laboratory test is described. The method successfully showed that there were large concentration gradients between the tube and tube support plate sides of the crevice. The testing also showed that strong bases concentrated more effectively than strong acids, and that the crevice pH, when exposed to seawater-based solutions, increased with increasing superheat and decreasing bulk concentration. The large variations in the crevice chemistry observed under heat transfer were eliminated upon shutdown. These new test data suggest that it might be beneficial to evaluate the variation in the extent of stress corrosion cracking with tube support plate elevation found in some steam generators in light of local chemistry changes, as well as the variation ...

2001-05-08

191

Development of a high performance air heater through use of an evacuated tube cover design  

Science.gov (United States)

Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance ...

1980-01-01

192

Constant extension rate (CERT) testing of alloy 690 and 800 nuclear steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT test results (such as maximum stress achieved and crack morphology) are ...

1994-12-31

193

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic ...

2000-03-01

194

Torsion of moderately thick hollow tubes with polygonal shapes  

British Library Electronic Table of Contents (United Kingdom)

A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.

2007-01-01

195

Thermally isolated pipeline  

Energy Technology Data Exchange (ETDEWEB)

The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.

1980-08-28

196

Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion  

International Nuclear Information System (INIS)

Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.

1993-01-01

197

Stress corrosion cracking of Alloy 600 using the constant strain rate test  

International Nuclear Information System (INIS)

Nuclear grade production tubing of Alloy 600 was evaluated for stress corrosion cracking (SCC) susceptibility in high purity water at 365, 345, 325, and 290 C. Reverse tube U-bend specimens provided crack initiation data and constant extension rate tests were employed to determine the crack velocities experienced in th crack propagation stage. Initial results indicate that a linear extrapolation of data received from high temperature tests can be used to predict the service life of steam generator tubing that has been plastically deformed or is continually deforming by ''denting.''.

198

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

199

Heat transfer characteristics of laminar flow in internally finned tubes under various boundary conditions  

Science.gov (United States)

Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.

1994-06-01

200

Feasibility study on scheme of disposing spent guide tubes at Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country

1998-12-01

201

Evaluation of optimum sheath electric field for selective production of metallic carbon nanotubes  

International Nuclear Information System (INIS)

We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.

2006-03-21

202

Design parameters for tube cavity receivers in solar power plants  

Energy Technology Data Exchange (ETDEWEB)

The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.

1981-01-01

203

Application of neutron radiography to visualization of multiphase flows  

Energy Technology Data Exchange (ETDEWEB)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-04-01

204

Application of neutron radiography to visualization of multiphase flows  

International Nuclear Information System (INIS)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-01-01

205

Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts  

Science.gov (United States)

Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.

1986-05-01

206

An investigation of turbulent convection heat transfer performance in spiral spring coil inserted tubes  

International Nuclear Information System (INIS)

This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.

1996-01-01

207

A new procedure for cutting out the broken thermocouple tubes inside the deep holes in the tube plate of moisture re-heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)

2005-09-01

208

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

209

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

210

The interventional treatment for biliary recurrent obstruction after palliative T tube drainage in patients with obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice

2002-10-01

211

Strain Rate Effects on Ultimate Strain of Copper  

Science.gov (United States)

... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...

1979-05-01

212

Steam Generator Group Project: Annual report, 1985  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

1987-04-01

213

Steam Generator Group Project: Annual report, 1985  

International Nuclear Information System (INIS)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

214

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

216

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe ...

1999-07-15

217

Indium(III) Compounds Containing the Neopentyl Substituent ...  

Science.gov (United States)

... learn more about the thermal stability of InNP2 Me, a sample contained in a previously evacuated tube was heated at 100°C for 13 days. Neither ...

1989-02-24

218

History of Bioterrorism: Botulism  

Medline Plus

... Pan Flu Preparedness YouTube is Your Friend Additional Resources ... Response Hurricane Readiness in High-Risk Areas: Survey Results Elements of ...

219

Far-out Pathways to Space: Great Guns? - ISTP  

Science.gov (United States)

The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he ...

220

Far-out Pathways to Space: Great Guns?  

Science.gov (United States)

Turbine Afterword The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he envisioned...

2011-09-03

221

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

222

Development of a FeCoNb Alloy to be used in Eddy Current ...  

Science.gov (United States)

... Accession Number : ADD336001. Title : Development of a FeCoNb Alloy to be used in Eddy Current Probes for Testing Ferromagnetic Tubes,. ...

223

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

224

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

225

Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes  

Science.gov (United States)

... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...

226

Burner systems  

Energy Technology Data Exchange (ETDEWEB)

A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient parameters across the combustion chamber ...

1984-07-10

227

BAM: Staphylococcal Enterotoxins  

Science.gov (United States)

... Dialysis tubing. Cellulose casing of 1-1/8 inches flat width and an average pore diameter of 48 Angstrom units is used (12,000-14,000 mol wt exclusion). ...

228

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

229

Application of Combined Enhanced Techniques for Design of Highly Efficient Air Heat Transfer Surface  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...

2012-01-01

230

A New Tool for Accurately Measuring the Inside Diameter of a ...  

Science.gov (United States)

Page 1. AD-769 272 A NEW TOOL FOR ACCURATELY MEASURING THE INSIDE DIAMETER OF A GUN BARREL, LONG TUBE, OR SIMILAR ...

1973-08-29

231

120-MM Gun Tube Erosion Including Surface Chemistry ...  

Science.gov (United States)

... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...

1997-10-01

232

(12) United States Patent  

Science.gov (United States)

Sep 19, 2005 ... within a sealed tube to control the environment to which a sample mounts are better suited to handling the very small crystal is exposed. ...

233

On the dependence of some helium shell flash characteristics on core mass  

Energy Technology Data Exchange (ETDEWEB)

A theoretical derivation of the intershell mass--core mass relation of Paczynski is attempted. Formulae developed by Sugimoto and Fujimoto are extended to less massive (m/sub c/< or approx. =1) cores.

1980-08-15

234

Stellar evolution. II - The evolution of a 3 sun-mass star from the main sequence through core helium burning.  

Science.gov (United States)

Three Sun-mass star evolution from main sequence to helium exhaustion in core, noting chronology of

1965-01-01

235

Mass public health programmes and the obligations of sponsoring and participating organisations  

UK PubMed Central (United Kingdom)

The obligations of organisations associated with policy formation and implementation of international mass public health programmes are explored. Lines of responsibility are considered to become unclear...Full Text Available

2006-10-01

237

Flavor Mixing, Quark Masses, Neutrino Masses and Neutrino Oscillations  

CERN Document Server

We discuss first the flavor mixing of the quarks, using the texture zero mass matrices. Then we study a similar model for the mass matrices of the leptons. We are able to relate the mass eigenvalues of the charged leptons and of the neutrinos to the mixing angles and can predict the masses of the neutrinos. We find a normal hierarchy - the masses are 0.004 eV, 0.01 eV and 0.05 eV. The atmospheric mixing angle is given by the mass ratios of the charged leptons and the neutrinos. we find about 40 degrees, consistent with the experiments. The mixing element, connecting the first neutrino wit the electron, is predicted to be 0.05. This prediction can soon be checked by the Daya Bay experiment.

2009-01-01

238

Calibrating Cosmological Chronometers: White Dwarf Masses ...  

Science.gov (United States)

... The second scenario is limited by the age of our Galaxy such that the lowest-mass WD that could be formed via single star evolution is ~0.47 M ...

2011-05-14

239

Mass measurements of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc and their impact on the rp-process  

Energy Technology Data Exchange (ETDEWEB)

The masses of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of ...

2010-07-01

240

Mass measurements of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc and their impact on the rp-process  

International Nuclear Information System (INIS)

The masses of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of ...

2010-03-15

241

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the ...

2009-07-01

242

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of ...

2009-03-16

243

Tracheal laceration during intubation of a double-lumen tube and intraoperative fiberoptic bronchoscopic evaluation through an LMA in the lateral position -A case report-  

UK PubMed Central (United Kingdom)

A 76-year-old, 148-cm woman was scheduled for right upper lobectomy. A 32 Fr left-sided double lumen tube was placed using a conventional technique. Despite several attempts under fiberoptic bronchoscope-guidance,...Full Text Available

2011-04-01

244

Thermal/hydraulic tests of tube supports in a multi-tube steam generator model  

International Nuclear Information System (INIS)

Tube supports used in the tube bundles of PWR steam generators have consisted of mechanical devices located at intervals along the tube bundle. The presence of tube supports creates regions of restricted flow with altered flow patterns and increased pressure drop. An additional and very important effect is also the possibility of local complete vaporization or dryout occurring in the tube/support flow passage and crevices. The thermal/hydraulic conditions at which dryout occurs are of particular interest because of the possibility of the deposition of dissolved solids with the occurrence of dryout. As long term build-up of solid deposition could have a deleterious effect, knowledge of the conditions at which dryout occurs would possibly provide a means to avoid this build-up. A test program, sponsored by the Steam Generator Project Office of the Electric Power Research Institute, ...

1985-03-01

245

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

246

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

247

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

248

PWR steam generator chemical cleaning process  

International Nuclear Information System (INIS)

Some of the origins of corrosion encountered in the secondary side of pressurized water reactor steam generators are:-sludge accumulation (a mixture of metal oxides, primarily magnetite and copper) on tube sheet and attack of tube support plates by aggressive impurities leading to denting. Although Electricite de France has not suffered from these problems, it has developed a chemical cleaning process to dissolve corrosion products at both locations. (author).

1986-10-13

249

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

250

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

251

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube ...

2003-12-01

252

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings ...

2003-12-01

253

Esophageal perforation following bite of inner tube of automobile tyre: An unusual cause of barotrauma  

UK PubMed Central (United Kingdom)

An 8-year-old child presented with severe chest pain and respiratory distress after he accidentally bit an automobile tyre tube which burst into his mouth. The chest radiograph revealed left-sided pneumothorax....Full Text Available

2010-01-01

254

Energy conservation via heat transfer enhancement. Quarterly progress report, October 1-December 31, 1979  

Science.gov (United States)

Contacts with researchers, manufacturers, and users of enhanced heat transfer equipment are summarized. The Technical Literature file and the Patent File continue to be updated; the Patent File is the source for a patent technology report now in draft form. Application studies on a rationally-based friction correlation for internally-finned tubes and on the evaluation of candidate tube-side enhancements for OTEC applications are reported. The technology study on enhancement of spray evaporation is also discussed.

1979-01-01

255

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

256

CERAMIC MEMBRANES FOR HYDROGEN PRODUCTION FROM COAL  

Energy Technology Data Exchange (ETDEWEB)

The preparation and performance of membranes for application to hydrogen separation from coal-derived gas is described. The membrane material investigated was dense amorphous silica deposited on a suitable support by chemical vapor deposition (CVD). Two types of support materials were pursued. One type consisted of a two-layer composite, zeolite silicalite/{alpha}-Al{sub 2}O{sub 3}, in the form of tubes approximately 0.7 cm in diameter. The other type was porous glass tubes of diameter below 0.2 cm. The first type of support was prepared starting from {alpha}-Al{sub 2}O{sub 3} tubes of 1{micro}m mean pore diameter and growing by hydrothermal reaction a zeolite silicalite layer inside the pores of the alumina at the OD side. After calcination to remove the organic template used in the hydrothermal reaction, CVD was carried out to deposit the final silica layer. CVD was carried out by alternating exposure of the surface with ...

2004-04-01

257

Bounding ingestion stream-tube determination via a CO tracer  

Energy Technology Data Exchange (ETDEWEB)

A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.

1998-05-01

258

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-07-01

259

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

International Nuclear Information System (INIS)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-10-05

260

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

261

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

262

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET ...

2002-07-01

263

Processing fine-grained and superplastic AZ31 Mg tubes for hydroforming  

Energy Technology Data Exchange (ETDEWEB)

The microstructures and mechanical properties of the AZ31 Mg tubes fabricated by one-pass forward piercing tube extrusion operated at 250-400 C and 10{sup -2}-10{sup 0} s{sup -1} are examined. The grain size is refined from the initial {proportional_to}75 {mu}m grain size down to {proportional_to}1.5 {mu}m. The room temperature tensile elongation along the extrusion direction also increases from {proportional_to}13% for the as-received billet up to 51%. The highest superplastic elongation of 610% was obtained as tensile loaded at 300 C and 2 x 10{sup -4} s{sup -1}, and high strain rate superplasticity of 406% and 502% was achieved at 300 C and 400 C with a high strain rate of 1 x 10{sup -2} s{sup -1}. Preliminary hydroforming or tube bulging at room temperature has demonstrated the feasibility. Hydroforming at elevated temperature of 200 C or above should exhibit much more promising results, utilizing the capability of LTSP ...

2004-07-01

264

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely restricting the growth ...

1988-03-25

265

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of ...

1998-11-15

266

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality ...

1978-01-01

267

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2006-07-01

268

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2005-11-20

269

Determination of water level profile along heat exchange tubes of horizontal steam generator PGV 1000 M  

International Nuclear Information System (INIS)

A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some permissible operating ...

270

Augmentation of heat transfer in a tube with an oscillating thin plate. Shindohen sonyu ni yoru enkannai netsudentatsu sokushin  

Energy Technology Data Exchange (ETDEWEB)

An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained explains that no sufficient turbulence can be obtained when the deflection angle of ...

1991-09-01

271

What masses for Cepheids  

Science.gov (United States)

To understand the evolution of giant stars, it is important to pin down the masses for Cepheids. The 7- to 10-day bump Cepheids imply lower than evolutionary mass (60%). Recent theoretical work, though, indicates that for Cepheids with periods of 15 to 16 days, the best understanding of the light curves results from using evolutionary masses.

273

Transition probability in "1"7"7Ta  

International Nuclear Information System (INIS)

... energy levels intermediate mass nuclei isotopes nuclei odd-even nuclei

275

Mass-energy spectra of fission fragments in the reaction {sup 242m}Am(n{sub th},f)  

Energy Technology Data Exchange (ETDEWEB)

The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.

1994-12-01

276

Life of the stars  

Energy Technology Data Exchange (ETDEWEB)

Stars and star evolution are discussed, including supernovae, nucleosynthesis, and mass-luminosity and Hertzsprung--Russell diagrams./aip/.

1988-09-20

279

Numerical and semi-analytic core mass distributions in supersonic isothermal turbulence  

CERN Document Server

We investigate the influence of the turbulence forcing on the mass distributions of gravitationally unstable cores by postprocessing data from simulations of non-selfgravitating isothermal supersonic turbulence with varying resolution. In one set of simulations solenoidal forcing is applied, while the second set uses purely compressive forcing to excite turbulent motions. From the resulting density field, we compute the mass distribution of gravitationally unstable cores by means of a clump-finding algorithm. Using the time-averaged probability density functions of the mass density, semi-analytic mass distributions are calculated from analytical theories. We apply stability criteria that are based on the Bonnor-Ebert mass resulting from the thermal pressure and from the sum of thermal and turbulent pressure. Although there are uncertainties in the application of the clump-finding ...

2010-01-01

280

Negative effective mass below a cut-off frequency  

CERN Document Server

Acoustic metamaterials with negative effective mass below a cut-off frequency are studied. An equivalent mass-spring structure is firstly proposed for such metamaterials, the effective mass is found to follow the Drude model: being negative below a specific frequency. The peculiar behavior is then verified by transmission experiments operating in the low-frequency regime. Inspired by the mass-spring model, we investigate the two-dimensional elastic waveguide with clamped boundaries and attribute the bandgap occurring below a critical frequency to negative effective mass density. The finding helps us to design a new acoustic Drude metamaterial, which enables shearing and bending deformations, in contrast to the membrane-type ones. Both simulation and experimental results show that the proposed metamaterial exhibits negative effective mass below 1200 Hz, thus ...

2010-01-01

281

Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

1998-05-25

282

Influence of carbon and nitrogen on corrosion resistance of high purity Fe-50mass% Cr alloys  

International Nuclear Information System (INIS)

High purity Fe-50mass%Cr alloys containing (C+N) in the range of 30 to 500 mass ppm were prepared and their corrosion resistance was investigated. Pitting potential in a 3.5mass%NaCl solution at 343K rose with reducing (C+N) content. Alloys containing (C+N) at less than 100 mass ppm did not sustain pitting corrosion. However, alloys containing 500 mass ppm (C+N) corroded severely in 6%FeCl_3+1/20N HCl solutions. Heat treatment at 923K was recognized as influencing corrosion resistance due to precipitation of carbonitrides only in the case of the alloy containing 500 mass ppm (C+N). (orig.).

283

GENERALIZED ATOMIC MASS LAW  

Science.gov (United States)

Least-squares analyses were performed on a set of atomic masses using standard and generalized senaiempirical mass laws. Presumably because of errors in the assured form of the standand mass law, its least-squares coefficients can be determined at best to an accuracy of about 10%, and masses are predicted with an uncertainty of several Mev/c/sup 2/. The standard mass law was generalized by addition of shell effect and deformation terms. While the least-squares fitting of the generalized mass law is better than for the standard mass law, it is still not possible to predict atomic masses to an accuracy better than a few Mev/c/sup 2/. The nuclear deformations and the well depth . of the nuclear interaction obtained from the additional mass-law terms are in reasonable agreement ...

1959-11-15

284

Accurate evolutions of unequal-mass neutron-star binaries: properties of the torus and short GRB engines  

CERN Document Server

We present new results from accurate and fully general-relativistic simulations of the coalescence of unmagnetized binary neutron stars with various mass ratios. The evolution of the stars is followed through the inspiral phase, the merger and prompt collapse to a black hole, up until the appearance of a thick accretion disk, which is studied as it enters and remains in a regime of quasi-steady accretion. Although a simple ideal-fluid equation of state with \\Gamma=2 is used, this work presents a systematic study within a fully general relativistic framework of the properties of the resulting black-hole--torus system produced by the merger of unequal-mass binaries. More specifically, we show that: (1) The mass of the torus increases considerably with the mass asymmetry and equal-mass binaries do not produce significant tori if they have a total baryonic mass ...

2010-01-01

285

Viscoelastic locally resonant double negative metamaterials with controllable effective density and elasticity  

British Library Electronic Table of Contents (United Kingdom)

A metamaterial that is composed of solid viscoelastic elements with controllable properties is proposed in this Letter. This enables an adaptable and general acoustic metamaterial to be practically realised. An array of masses with a single elastic connection to a supporting viscoelastic structure, such as one that is dynamically equivalent to an array of Helmholtz resonators, only provides a system with negative effective mass. A local active control scheme applied to each of these masses can emulate additional elastic connections to the supporting structure. An array of masses with a suitable local control scheme can provide both the negative effective stiffness and mass required for negative refraction. The tuneable feedback control parameters determine the characteristics of the region...

2010-01-01

286

Nucleon and meson effective masses in the relativistic mean-field theory  

Energy Technology Data Exchange (ETDEWEB)

Nucleon and meson effective masses in the nonlinear relativistic mean-field theory introducing a nonlinear {omega}-{rho} and {sigma} coupling motivated by the quark-meson coupling model is explored. It is shown that, in contrast to the usual Walecka model, not only the effective nucleon mass m{sub eff,N} but also the effective {sigma},{rho} meson masses (m{sub eff{sigma}},m{sub eff,{rho}}) and the effective {omega} meson mass m{sub eff,{omega}} are nucleon density dependent. (author)

2001-10-01

287

Nucleon and meson effective masses in the relativistic mean-field theory  

International Nuclear Information System (INIS)

Nucleon and meson effective masses in the nonlinear relativistic mean-field theory introducing a nonlinear #omega#-#rho# and #sigma# coupling motivated by the quark-meson coupling model is explored. It is shown that, in contrast to the usual Walecka model, not only the effective nucleon mass m_e_f_f_,_N but also the effective #sigma#,#rho# meson masses (m_e_f_f_#sigma#,m_e_f_f_,_#rho#) and the effective #omega# meson mass m_e_f_f_,_#omega# are nucleon density dependent. (author)

2001-10-01

288

Mira variables - Pulsation, mass loss and evolution  

International Nuclear Information System (INIS)

Recent developments in the analysis of Mira atmosphere, the determination of the pulsation mode, the problem of mass loss, and the evolution of the Mira variables are covered. Model atmospheres for Mira variables, including the opacities of the molecules expected in very late M-type atmospheres are discussed. The pulsation constant for Omicron Ceti is evaluated using T(eff) = 2900 + or - 200 K, and it is concluded that Miras are fundamental mode pulsators. The importance of molecular opacity to the driving of mass loss is evaluated, and it is pointed out that the radiation pressure on molecules is not a major factor in driving mass loss from Mira. Mass loss is considered as a factor in the calculations of the periods for Mira variables. 30 refs.

1990-05-28

289

Mass of the nucleon in a chiral quark-diquark model  

International Nuclear Information System (INIS)

The mass of the nucleon is studied in a chiral quark-diquark model. Both scalar and axial-vector diquarks are taken into account for the construction of the nucleon state. After the hadronization procedure is used to obtain an effective meson-baryon Lagrangian, the quark-diquark self-energy is calculated to generate the baryon kinetic term as well as determine the mass of the nucleon. It turns out that both the scalar and axial-vector parts of the self-energy are attractive for the mass of the nucleon. We investigate the range of parameters that can reproduce the mass of the nucleon.

2005-09-01

290

Mass distribution of fission products in the 28.5 MeV alpha particle induced fission of "2"3"2Th  

International Nuclear Information System (INIS)

Mass distribution in 28.5 MeV alpha particle induced fission of "2"3"2Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of "2"3"5U. (orig.).

291

Mass distribution of fission products in the 28. 5 MeV alpha particle induced fission of sup 232 Th  

Energy Technology Data Exchange (ETDEWEB)

Mass distribution in 28.5 MeV alpha particle induced fission of {sup 232}Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of {sup 235}U. (orig.).

1989-01-01

292

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

293

A multilayered acoustic hyperlens with acoustic metamaterials  

British Library Electronic Table of Contents (United Kingdom)

The acoustic hyperlens can be realized by an alternating layered structure of water and fluid with negative mass density. Based on this alternating layered principle, we propose that an acoustic metamaterial consisting of three layers in water background can be designed to replace the fluid with negative mass density. The effective mass density and bulk modulus of the system which is composed of acoustic metamaterial and water are functions of the frequency. The effective mass density of such a system is close to the negative mass density of the fluid at a specific frequency; thus an acoustic metamaterial hyperlens can be achieved.

2011-01-01

294

Ultra-high temperature strength properties on Mod.9Cr-1Mo steel  

Energy Technology Data Exchange (ETDEWEB)

A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were ...

2000-03-01

295

The Cause of an Eddy Current Signal Noise from a Steam Generator Tube and its Effect on the Detectability of a Crack  

International Nuclear Information System (INIS)

An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from ...

2008-05-01

296

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl ...

1997-05-27

297

Application of new corrosion-resistance superheater tubings for a 500 C, 100 Kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy plant  

Energy Technology Data Exchange (ETDEWEB)

A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic ...

1999-11-01

298

Analysis of defect detection in steam generator tubes of FBR, under support plates and in the presence of sodium using multi-frequency eddy current algorithms  

International Nuclear Information System (INIS)

In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer steam generator tube ...

2007-04-22

299

A thermal-hydraulic drift-flux based mixture-fluid model for the description of single- and two-phase flow along a general coolant channel  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Different to the very simple class of homogeneous non-equilibrium models (HEM) an one dimensional thermal-hydraulic theoretical drift-flux based and thus non-homogeneous coolant channel model and, as a result, an in itself complete thermal-hydraulic coolant channel module CCM have been established allowing to simulate in a very general way the steady state and transient behaviour of the most important parameters of a single- or two-phase fluid flowing within any type of heated or non-heated coolant channel (with an eventually varying cross flow area). To avoid mathematical discontinuities at the transition from single- to two-phase flow the coolant channel will, in its general form, be split into different regions, i.e. be looked as a basic channel (BC) which can consist of a number of different flow regimes and can, accordingly, be subdivided into a number of sub-channels (SC-s). All of them belong, obviously, to only two types of SC-s, a SC with an ...

2005-07-01

300

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

301

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. (Author)

1994-10-01

302

Summary of denting mechanism and kinetic studies with seawater  

International Nuclear Information System (INIS)

Studies at Commissariat a l'Energie Atomique (CEA) have been under way for three years in an attempt to find methods for preventing and stopping denting. Tests have been performed in 28 model boilers (Ajax with U tubes and Clarinette with straight tubes). In these boilers, with continous injection and blowdown, and heat flux is about 40 W X cm"-"2 (126900 Btu/ft"2 X h). The kinetics of denting has been studied with different levels of faulting. Some high-temperature electrochemical measurements established the mechanism of denting in the boiler tests. Denting kinetics can be rationalized in terms of three main parameters: faulting level, heat flux, and relative mechanical strength of the tube compared to the support plate.

303

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.

1986-11-17

304

Research of time-domain equivalent circuit method in solving dispersion of coupled-cavity traveling-wave tube  

International Nuclear Information System (INIS)

In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)

2008-09-01

305

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

306

Process for filling tubular plates for lead batteries. Verfahren zum Fuellen von Rohrplatten fuer Bleiakkumulatoren  

Energy Technology Data Exchange (ETDEWEB)

The following method is proposed as a supplement to main patent 2419107, which deals with the filling of tubular plates surrounding the lead cores: the flat materials which are used to produce the jacket tubes are prepared before forming into jacket tubes by a film producing aqueous carboxy-methyl cellulose solution closing the pores. The preparation can be done by coating the flat material with a soluble foil. After pressing the paste in, the tubular plates are dried and after cooling are dipped into sulphuric acid with a specific gravity of 1.24 g/cm/sup 3/. The carboxy-methyl cellulose is dissolved and the permeability of the tube walls for electrolyte is restored after only 15 minutes.

1981-06-19

307

Offshore drilling rig with enclosed work area  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.

1987-12-01

308

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

309

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

310

Mechanical design of a PERMCAT reactor module  

International Nuclear Information System (INIS)

The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.

2007-02-01

311

Life extension of boilers using weld overlay protection  

Energy Technology Data Exchange (ETDEWEB)

The presentation describes the status of modern weld overlay technology for refurbishment, upgrading and life extension of boilers. The approaches to life extension of boilers include field overlay application, shop-fabricated panels for replacement of the worn, corroded waterwall and shop-fabricated overlay tubing for replacement of individual tubes in superheaters, generating banks and other areas. The characteristics of weld overlay products are briefly described. Also discussed are successful applications of various corrosion-resistant overlays for life extension of boiler tubes in waste-to-energy boilers, coal-fired boilers and chemical recovery boilers. Types of corrosion and selection of weld overlay alloys in these systems are also discussed. (orig.) 14 refs.

1998-12-31

312

Improvement of the PGV-1000 steam generator in-vessel components  

International Nuclear Information System (INIS)

Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.

1988-01-01

313

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

314

Heat transfer augmentation in liquid metal reactor steam generators  

International Nuclear Information System (INIS)

The use of heat transfer augmentation devices has been proposed as a means for reducing the cost of steam generators for advanced LMR designs by approximately 25%. Experimental results are presented for two types of enhancers in the form of a twisted-tape and a core-tube insert in the steam tube of a 13.1-m-long, sodium-heated single-tube test section. Test parameters were prototypical of liquid metal reactor (LMR) steam generator design for a once-through high-pressure steam cycle. Heat transfer results are compared with the no-insert case on an overall and local basis. Although both augmentations increased overall performance, the mechanisms were different.

315

Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes  

Energy Technology Data Exchange (ETDEWEB)

RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).

1996-12-31

316

Assessment of degradation processes in corrosion resistant steels in nuclear power engineering  

International Nuclear Information System (INIS)

The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient can be produced at the tube-tube plate joint. (Z.M.). 1 fig., 1 tab., 10 refs.

1987-12-01

317

Masses of Neutron Stars in High-Mass X-ray Binaries with Optical Astrometry  

CERN Document Server

Determining the type of matter that is inside a neutron star (NS) has been a long-standing goal of astrophysics. Despite this, most of the NS equations of state (EOS) that predict maximum masses in the range 1.4-2.8 solar masses are still viable. Most of the precise NS mass measurements that have been made to date show values close to 1.4 solar masses, but a reliable measurement of an over-massive NS would constrain the EOS possibilities. Here, we investigate how optical astrometry at the microarcsecond level can be used to map out the orbits of High-Mass X-ray Binaries (HMXBs), leading to tight constraints on NS masses. While previous studies by Unwin and co-workers and Tomsick and co-workers discuss the fact that the future Space Interferometry Mission should be capable of making such measurements, the current work describes detailed simulations for 6 HMXB ...

2010-01-01

318

Double core evolution. IV - The late stages of evolution of a 2-solar mass red giant with a 1-solar mass companion  

International Nuclear Information System (INIS)

The paper reports on the results of hydrodynamical simulations of the late phase of the common envelope stage of a binary consisting of a 2-solar mass red giant and a 1-solar mass main-sequence companion. The numerical results demonstrate that sufficient energy is released from the orbit to eject the mass within the common envelope without requiring the main-sequence companion to spiral into the white dwarf core of the red giant star. At the end of the simulation the orbital decay time scale increases rapidly to more than 160 yr. The long decay time scale reflects the removal of mass from the common envelope and its subsequent spin-up to near corotation. The ratio of the orbital decay time scale to the mass-loss time scale from the common envelope increases to more than 700, and the mass contained within the common envelope decreases to about 0.01 solar ...

319

Locally resonant acoustic metamaterials with 2D anisotropic effective mass density  

British Library Electronic Table of Contents (United Kingdom)

A two-dimensional (2D) lattice model with anisotropic resonant microstructures is found to provide an anisotropic band gap structure. A 2D continuum with anisotropic effective mass density is introduced to represent this lattice system. Two methods are proposed to derive the equivalent continuum. In the first method, the effective mass density of the equivalent continuum is obtained by matching the dispersion relations for harmonic waves propagating in the principal directions. The second approach employs an approximate estimation of the effective mass density by volume-averaging an effective mass that represents the resonant microstructure. For both equivalent continuum models, the effective mass density is frequency-dependent and may become negative in certain frequency ranges. Subsequen...

2011-01-01

320

Energetics of the fission process  

Energy Technology Data Exchange (ETDEWEB)

The mass asymmetry of fragments from nuclear fission of heavy nuclei is reviewed. While mass asymmetry is a common and well-known phenomenon for low-energy fission of the lighter actinides, more recent experiments have demonstrated that, for the heaviest actinides, the mass distribution switches to a symmetric one. On the other hand, it has been discovered that, though for fissioning nuclei with mass numbers A< or [approx]225 the mass distribution is basically symmetric, an asymmetric component is clearly to be identified for nuclei down to the Pb-region. In the absence of a generally accepted dynamical theory of fission, the above experimental findings are discussed in terms of static energy considerations. Triggered from the outset by the structure of the potential energy surface at the saddlepoint, the energy balance at the scission point between the available energy (Q-value) ...

1994-09-01

321

Energetics of the fission process  

International Nuclear Information System (INIS)

The mass asymmetry of fragments from nuclear fission of heavy nuclei is reviewed. While mass asymmetry is a common and well-known phenomenon for low-energy fission of the lighter actinides, more recent experiments have demonstrated that, for the heaviest actinides, the mass distribution switches to a symmetric one. On the other hand, it has been discovered that, though for fissioning nuclei with mass numbers A< or #approx#225 the mass distribution is basically symmetric, an asymmetric component is clearly to be identified for nuclei down to the Pb-region. In the absence of a generally accepted dynamical theory of fission, the above experimental findings are discussed in terms of static energy considerations. Triggered from the outset by the structure of the potential energy surface at the saddlepoint, the energy balance at the scission point between the available energy (Q-value) ...

322

p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene.  

UK PubMed Central (United Kingdom)

Alkylphenols are widely used as plastic additives and surfactants. We report the identification of an alkylphenol, nonylphenol, as an estrogenic substance released from plastic centrifuge tubes. This...Full Text Available

1991-05-01

323

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

324

The Mechanism and the Magnitude of Flow Boiling Augmentation in Tubes with Discrete Surface Roughness Elements (III).  

Science.gov (United States)

Related to other research on the effectiveness of flow boiling heat transfer augmentation using various types of turbulators this investigation comprises a definitive study of the effect of large discrete roughness elements on heat transfer over the entir...

1972-01-01

325

Study of nuclear materials by neutron scattering.  

Science.gov (United States)

Following studies on fiber and sheet texture of hexagonal crystal system in 1988, work has been extended to tube texture. Using the zircaloy-4 fuel cladding of Wolsung-type reactor as specimen, six pole figures for different crystallographic planes were m...

1990-01-01

326

Staphylococcal Enterotoxin B: Solid-Phase Radioimmunoassay  

UK PubMed Central (United Kingdom)

An immunoassay employing 125I-labeled enterotoxin B and polystyrene tubes coated with specific antibody was used for assaying purified and crude enterotoxin. Antibody was adsorbed to untreated...Full Text Available

1971-11-01

327

Solid-Phase Radioimmunoassay of Total and Influenza-Specific Immunoglobulin G  

UK PubMed Central (United Kingdom)

An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available

1972-02-01

328

Site Error There's a problem with ... - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Bending moments recorded by sensors on the aluminum tube. ... the escape rocket motor, tests also were made with the escape tower and rocket .... Incoming photographic data will be electronically converted and processed ...

329

Problems and prospects of using structural materials for horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Prospects for using new structural materials instead of Grade 08Kh18N10T steel for making heat-transfer tubes for horizontal steam generators with the purpose to increase their service life from 30?40 to 60 or more years are considered.

2011-01-01

330

Novel Technique for Aerodynamic Force Measurement in Shock Tubes.  

Science.gov (United States)

For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...

1989-01-01

331

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

332

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-05-01

333

Minimal distensibility of pulmonary capillaries in avian lungs compared with mammalian lungs  

UK PubMed Central (United Kingdom)

Previous physiological studies suggest that avian pulmonary capillaries behave like almost rigid tubes. We made morphometric measurements to determine the diameter of the capillaries in chicken...Full Text Available

2008-02-01

334

Membrane nanotubes induced by aqueous phase separation and stabilized by spontaneous curvature  

UK PubMed Central (United Kingdom)

Tubular membrane structures are widespread in eukaryotic cells, but the mechanisms underlying their formation and stability are not well understood. Previous work has focused on tube extrusion from...Full Text Available

2011-03-22

335

Magnetic Fields in Massive Stars. II. The Buoyant Rise of Magnetic Flux Tubes Through the Radiative Interior  

CERN Document Server

We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time scale for this ...

2003-01-01

336

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

338

Fluid dynamics analysis of a Ranque-Hilsch vortex tube  

International Nuclear Information System (INIS)

Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy ...

2008-05-01

339

Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies  

UK PubMed Central (United Kingdom)

BackgroundThe diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi). However, a more rapid, simpler,...Full Text Available

340

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the corrosion rate of materials positioned in the ...

1998-07-01

341

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K{sup Iscc}, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most ...

2002-07-01

342

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

International Nuclear Information System (INIS)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K"I"s"c"c, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most corrosive ...

2002-05-05

343

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

344

Does My Child Have ADHD?  

Medline Plus

September 14, 2010 ADHD: Signs, Symptoms, Research NIMH researchers talk about the symptoms of ADHD as well as the latest research. Download this video. Watch on YouTube. Transcript Announcer: ADHD- Attention Deficit Hyperactivity Disorder- is one of the ...

345

Cross flow boiling in tube bundles  

Science.gov (United States)

This report contains two main subjects. One is the newly started investigation of cross flow boiling in tube bundles. The heat transfer information at this condition is of significant importance to horizontal steam generator design. The other one is the continuation of the research on boiling heat transfer in confined spaces. The research on cross flow boiling in tube bundles has been started. The Freon loop has been modified for higher flow and higher two phase quality. The test section design is finished and is under fabrication presently. The new instrumentation system is also established. The test matrix has been planned. The research on boiling in confined spaces proceeds steadily. This problem is of great importance to the boiling induced corrosion in the steam generator crevices between the tube and the support plate. In the report of 1981, detailed results were presented for analysis of single phase flow, two phase ...

1982-10-01

346

Coolant rate distribution in horizontal steam generator under natural circulation  

Energy Technology Data Exchange (ETDEWEB)

In the presentation the major factors determining the conditions of NCC (Natural Coolant Circulation) in the primary circuit and in particular conditions of coolant rate distribution on the horizontal tubes of PGV-1000 in NPP with VVER-1000 under NCC are considered. 5 refs.

1997-12-31

347

Conservative management of post traumatic thoraco diaphragmatico biliary fistula  

UK PubMed Central (United Kingdom)

We report herein a case of thoraco diaphragmatico biliary fistula in a 24-year-old male who was managed conservatively with antibiotics and tube thoracostomy and had complete radiological clearance.

2010-10-01

348

Comparative Inhibitory Effects of Antigen and Antibody in the Staphylococcal Enterotoxin Solid-Phase Radioimmunoassay System  

UK PubMed Central (United Kingdom)

A solid-phase radioimmunoassay employing 125I-labeled enterotoxins and polystyrene tubes coated with specific antibody has been developed for assaying the relative concentrations of antibodies...Full Text Available

1975-06-01

349

Chromium steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to investigation of alternative support designs and materials. In recent designs of steam generators the carbon steel drilled hole tube support plate has been replaced by one of quatrefoil or trefoil shape to minimize the contact area. These plates are now made of more corrosion resistant chromium steel (approx. 12%Cr) to ensure that they are less vulnerable to attack in the event of adverse boiler water chemistry. This study was initiated to examine the corrosion behavior of a range of chromium steels in the acid chloride environments characteristic of tube/support plate crevices under adverse boiler water conditions. Objectives of the study were to: 1) determine the relative susceptibility of candidate tube support plate steels to acid chloride corrosion; 2) investigate the ...

1985-03-01

350

Changing the emphasis at Bruce A  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

1994-01-01

351

Changing the emphasis at Bruce A  

International Nuclear Information System (INIS)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

352

Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue  

Energy Technology Data Exchange (ETDEWEB)

Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of water along the tube ...

2009-10-15

353

Astronaut Jeff Williams Answers Your Questions  

National Aeronautics and Space Administration (NASA)

Expedition 22 Commander Jeff Williams, aboard the International Space Station 220 miles above Earth, responds to questions posted on YouTube concerning the station's orientation, life in space and the recent butterfly experiment.

2010-03-10

354

A post-labeling method for multiplexed and multicolored genotyping analysis of SSR, indel and SNP markers in single tube with bar-coded split tag (BStag)  

UK PubMed Central (United Kingdom)

BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available

355

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

356

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

Energy Technology Data Exchange (ETDEWEB)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described ...

2007-07-01

357

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

International Nuclear Information System (INIS)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described in this ...

2007-08-19

358

Theoretical investigations of strength of a flexible tube made of NiTi; Festigkeitstheoretische Untersuchungen einer flexiblen Huelse aus NiTi  

Energy Technology Data Exchange (ETDEWEB)

A flexible, steerable tube (distal end) of an endoscope for the application in the laparoscopic surgery has been analyzed by means of the finite-element-method (FEM). The unusual mechanical and thermal features of the used shape memory alloy (SMA) of NiTi were taken in account. The analyses showed that the strains remain in the super-elastic region up to the maximum bending of 90 and no plastic deformations occur. The application of the shape optimization (CAO) made possible finding the optimal structure of the distal end and therefore powerful reducing the maximum strains in the critical regions. (orig.)

2000-04-01

359

Tank of sodium cooled fast reactor  

International Nuclear Information System (INIS)

Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).

360

TVA's program to mitigate steam generator denting at Sequoyah and Watts Bar Nuclear Plants  

International Nuclear Information System (INIS)

TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.

1983-09-25

361

Process to eliminate the deposits formed in a steam generator of a pressurized water nuclear reactor  

International Nuclear Information System (INIS)

The present process allows to eliminate the corrosion products formed on the tube plates and in the interstices of plate-tube crosspieces of a PWR steam generator in order to avoid a corrosion phenomenon which may cause denting by presence of oxides. The process consists in applying on these oxides at about 50-100 degrees, an aqueous solution containing 6-8% of gluconic acid, 3-5% of citric acid, about 0.5% of a corrosion inhibitor and ammonia until a pH of 3-9.5 is obtained.

1984-04-05

362

Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope  

Science.gov (United States)

This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.

2008-04-01

363

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

364

Microwave heating type evaporator  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To prevent evaporization stills against corrosion due to radioactive liquid wastes. Constitution: Microwaves are supplied from a microwave generator by way of a wave guide tube and through a microwave permeation window to the inside of an evaporatization still. A matching device is attached to the wave guide tube for transmitting the microwaves in order to match the impedance. When the microwaves are supplied to the inside of the evaporization still, radioactive liquid wastes supplied from a liquid feed port by way of a spray tower to the inside of the evaporization still is heated and evaporated by the induction heating of the microwaves. (Seki, T.).

1987-01-22

365

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

366

Integrity assessment of pressure tubes for Wolsung unit 2  

Energy Technology Data Exchange (ETDEWEB)

To improve operational safety of the fuel channel for Wolsung units the recommended primary heat transport system (PHTS) operating guidelines were developed, which provides a safe operation window in terms of pressure and temperature to maintain fuel channel integrity, which is similar to pressure-temperature curves used for primary pressure boundary integrity in PWRs and deterministic Leak-Before Break (LBB) analyses were conducted using recent understanding of delayed hydride cracking (DHC) mechanism. In addition, a comparative assessment of LBB analysis was made using the procedures of Fitness For Service Guidelines(FFSG) for pressure tubes rev. 0 and rev. 1.

1997-10-01

367

Implementation and management of Daya Bay Nuclear Power Plant in-core flux thimble tube in-service inspection  

International Nuclear Information System (INIS)

This article discusses the Daya Bay nuclear power plant in-core flux thimble tube in-service inspection method and strategy. High light of the multiple frequency eddy current technology adopted including frequency and probe choice, standard design, data acquisition process are involved. The wear defect-growing trends are studied on base of the history data, which contribute to the in-service inspection strategy decision. (authors)

2003-04-08

368

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

369

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

370

Development of ALLOY 800 for PWR/SG tubings resistant to IGSCC and general corrosion  

Energy Technology Data Exchange (ETDEWEB)

Resistance of ALLOY 800 as a PWR/SG tubings to IGC/IGSCC and Ni, Co release into high temperature water was evaluated as compared with ALLOYs 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made. From the results, ALLOY 800 was evaluated to be the most reliable among the high Ni alloys tested. In addition, the alloy would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti and Nb, and the prior oxidation treatments, respectively. (author).

1989-07-01

371

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

372

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

373

Design criterion for tubed solar-heated cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiences, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.

1986-07-01

374

Design criterion for tubed solar-heated cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiencies, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.

1986-01-01

375

Corrosion performance of tube support materials  

International Nuclear Information System (INIS)

The problem of denting in steam generators leads to change in the conception of the tube support plates. A new material is now used for this component, a 13% Cr steel, which composition has been adjusted for weldability and mechanical resistance criteria. The geometry of trefoil support plate (TSP) has also been improved, using a broached TSP (quadrifoiled holes) instead of a drilled TSP. Tests have been performed on 13% Cr and C-steel broached TSP, and drilled TSP, to confirm the better resistance to denting of this new configuration.

1985-03-01

376

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

377

BNES materials conference a status review of alloy 800  

International Nuclear Information System (INIS)

Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).

378

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

379

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

380

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

381

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

382

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between the pressure tube channels is less than 100 mm and pipes in ...

1999-12-01

383

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

Energy Technology Data Exchange (ETDEWEB)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface ...

1996-01-01

384

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

International Nuclear Information System (INIS)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface ...

1992-01-01

385

Studies on the permeation of hydrogen through steam generator tubes at high temperatures using an electrochemical method  

Energy Technology Data Exchange (ETDEWEB)

The permeation of hydrogen through steam generator tubes at high temperatures ({approx} 300 degrees C) has been studied using an electrochemical technique. With this technique, hydrogen is generated on one side of the tube and monitored on the other side. The time for the hydrogen to reach the other side is used to determine the diffusion coefficient of hydrogen in the tube. Boundary conditions at the entry and exit sides have been investigated separately. Preliminary studies were performed on Stainless Steel 316 and Nickel Alloy 800 to better understand the influence of the solution chemistry on the electrochemical evolution of hydrogen. The surface phenomena effect and the trapping effect are discussed to account for differences observed in the permeation response. The hydrogen permeation through oxides at the exit side has been studied. Two nickel alloys (Alloy 800 and Alloy 600), materials widely used for steam ...

1998-07-01

386

Fatigue behavior of Alloy 690 and Alloy 800 SG tubing at temperatures up to 330{sup o}C in very high cycle fatigue regime  

Energy Technology Data Exchange (ETDEWEB)

During the service in nuclear power plants, steam generator (SG) tubing will suffer from a vibration with a frequency from 30-40 Hz. This means that SG tubing will undergo a very high cycle fatigue process during the design life time (25 years=about 3x10{sup 10}cycles). The material degradation and the very high cycle fatigue life of SG tubing materials due to the vibration are therefore of concern. In this investigation, the fatigue properties of Alloy 690 and Alloy 800 SG tubing in the very high cycle fatigue regime (higher than 10{sup 7} cycles) and strain controlled fatigue at temperatures up to 330{sup o}C have been investigated. The fatigue properties of SG tubing of Alloy 690 are comparable to that of wrought material. The strain controlled fatigue properties of Alloy 690 and Alloy 800 are slightly better at 288{sup o}C than at room temperature (RT). At the stress near the ...

2007-07-01

387

Fatigue behavior of Alloy 690 and Alloy 800 SG tubing at temperatures up to 330"oC in very high cycle fatigue regime  

International Nuclear Information System (INIS)

During the service in nuclear power plants, steam generator (SG) tubing will suffer from a vibration with a frequency from 30-40 Hz. This means that SG tubing will undergo a very high cycle fatigue process during the design life time (25 years=about 3x10"1"0cycles). The material degradation and the very high cycle fatigue life of SG tubing materials due to the vibration are therefore of concern. In this investigation, the fatigue properties of Alloy 690 and Alloy 800 SG tubing in the very high cycle fatigue regime (higher than 10"7 cycles) and strain controlled fatigue at temperatures up to 330"oC have been investigated. The fatigue properties of SG tubing of Alloy 690 are comparable to that of wrought material. The strain controlled fatigue properties of Alloy 690 and Alloy 800 are slightly better at 288"oC than at room temperature (RT). At the stress near the fatigue endurance, ...

2007-08-19

388

Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments  

Energy Technology Data Exchange (ETDEWEB)

The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG tubes under conditions simulating those ...

2001-09-01

389

EDF approach on OD corrosion of SG tubes  

Energy Technology Data Exchange (ETDEWEB)

The secondary side corrosion of steam generator tubes is the main degradation of components in operating power plants, strongly impacted by chemistry. This is why EDF has largely studied the chemical parameters in its 56 PWRs which might influence corrosion development. The results of 168 hideout returns of chemical species performed on the French plants allowed to draw conclusions on where chemical species are likely to concentrate in steam generators and on the influence of several contaminants on corrosion processes: sodium, chloride, phosphate, organic compounds, etc... Based on laboratory studies and plants feedback, new chemistry specifications were established and are now applied to EDF units to minimize corrosion and operating costs and to provide a good availability while maintaining an excellent safety. Boric acid is added in the secondary water of the 10 oldest units with Inconel 600 MA tubing, highly sensitive to intergranular ...

1998-12-31

390

Development of a numerical methodology to simulate the roller expansion forming process  

International Nuclear Information System (INIS)

A distinguishing design feature of CANDU nuclear reactors is the use of horizontal fuel channels housed in a horizontal vessel called a calandria, which is made of stainless steel 304L. Each channel consists of a Zr-2.5%Nb alloy pressure tube and an externally concentric Zr-2 calandria tube. The calandria tubes are joined to the end plates (tubesheets) of the calandria vessel by joints formed by roller expansion. The bores in the tubesheets are grooved. Roller expanded joints provide a cost effective means of joining dissimilar materials, require minimal space and no maintenance. The quality of these roller expanded joints is important from a sealing, strength and stress corrosion point of view. The roller expansion process consists of expanding the calandria tubes to deform them plastically against the bores and into the grooves of the tubesheets. Therefore, understanding the effect of the number, ...

2006-04-03

391

Delayed Hydride Cracking Mechanism in Zirconium Alloys and Technical Requirements for In-Service Evaluation of Zr-2.5Nb Tubes with Flaws  

International Nuclear Information System (INIS)

In association with periodic inspection of CANDU nuclear power plant components, Canadian Standards Association issued CSA N285.8 in 2005 as technical requirements for in-service evaluation of zirconium alloy pressure tubes in CANDU reactors. This first version, CSA N285.8 involves procedures for, firstly, the evaluation of pressure tube flaws, secondly, the evaluation of pressure tube to calandria tube contact and, thirdly, the assessment of a reactor core, and material properties and derived quantities. The evaluation of pressure tube flaws includes delayed hydride cracking evaluation the procedures of which are stipulated based on the existing delayed hydride cracking models. For example, the evaluation of flaw-tip hydride precipitation during reactor cooldown involves a procedure to calculate the equilibrium hydrogen equivalent concentration in solution at the flaw tip, Htipas ...

2007-05-10

392

Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests  

Energy Technology Data Exchange (ETDEWEB)

The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, ...

1998-10-01

393

Some properties of low-mass stellar models with chemically inhomogeneous neutral-stability zones  

Energy Technology Data Exchange (ETDEWEB)

Several low-mass models with an inhomogeneous radiative core and a convective envelope are investigated, the entire core or its upper portion being treated as a zone of neutral stability. Mixing by convective overshoot will then give rise to unstable structure.

1983-03-01

394

Scaling of offspring number and mass to plant and animal size: model and meta-analysis  

UK PubMed Central (United Kingdom)

The scaling of reproductive parameters to body size is important for understanding ecological and evolutionary patterns. Here, we derived allometric relationships for the number and mass of seeds, eggs...Full Text Available

2008-04-01

395

Mass spectrometric characterization of high-temperature outgassing of anisotropic pyrolytic boron nitride  

International Nuclear Information System (INIS)

This paper describes a system for fast mass spectrometric characterization of high-temperature outgassing measurements and measuring the total quantity of gas evolved for boron nitride. 2 references, 1 figure, 2 tables.

396

Mass Treatment with Azithromycin for Trachoma Control: Participation Clusters in Households  

UK PubMed Central (United Kingdom)

BackgroundMass treatment to trachoma endemic communities is a critical part of the World Health Organization SAFE strategy. However, non-participation may not be at random, affecting...Full Text Available

397

Mass Balance and Present-day Antarctic Rebound and Gravity Change  

Science.gov (United States)

Mass Balance and Present-day Antarctic Rebound and Gravity Change. Erik R. Ivins , Eric Rignot, Xiaoping Wu, Carol A. Raymond (JPLKaltech, 300-233,4800 Oak ...

398

Mapping neuropeptide expression by mass spectrometry in single dissected identified neurons from the dorsal ganglion of the nematode Ascaris suum  

UK PubMed Central (United Kingdom)

We have developed a method for dissecting single neurons from the nematode Ascaris suum, in order to determine their peptide content by mass spectrometry (MS). In this paper,...Full Text Available

2010-07-21

399

High-precision determination of the light-quark masses from realistic lattice QCD  

CERN Document Server

Three-flavor lattice QCD simulations and two-loop perturbation theory are used to make the most precise determination to date of the strange-, up-, and down-quark masses, $m_s$, $m_u$, and $m_d$, respectively. Perturbative matching is required in order to connect the lattice-regularized bare- quark masses to the masses as defined in the \\msbar scheme, and this is done here for the first time at next-to-next-to leading (or two-loop) order. The bare-quark masses required as input come from simulations by the MILC collaboration of a highly-efficient formalism (using so-called ``staggered'' quarks), with three flavors of light quarks in the Dirac sea; these simulations were previously analyzed in a joint study by the HPQCD and MILC collaborations, using degenerate $u$ and $d$ quarks, with masses as low as $m_s/8$, and two values of the lattice spacing, with chiral ...

2006-01-01

400

Establishment of trophectoderm and inner cell mass lineages in the mouse embryo  

UK PubMed Central (United Kingdom)

The first cell lineage specification in mouse embryo development is the formation of trophectoderm (TE) and inner cell mass (ICM) of the blastocyst. This article is to review and discuss the...Full Text Available

2009-11-01

401

Determination of Salirasib (S-trans, trans-farnesylthiosalicylic acid) in human plasma using liquid chromatography-tandem mass spectrometry  

UK PubMed Central (United Kingdom)

A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available

2008-06-15

402

Design and Construction of a Versatile Dual Volume Heteronuclear Double Resonance Microcoil NMR Probe  

UK PubMed Central (United Kingdom)

Improved NMR detection of mass limited samples can be obtained by taking advantage of the mass sensitivity of microcoil NMR, while throughput issues can be addressed using multiple, parallel...Full Text Available

2009-04-01

403

Dendrochronological Mass Balance Reconstruction, Strathcona Provincial Park, Vancouver Island, British Columbia, Canada  

Science.gov (United States)

... 036[0598:DMBRSP]2.0.CO;2 Dendrochronological Mass Balance Reconstruction, Strathcona Provincial Park, Vancouver Island, British ...

404

DNA sequencing using biotinylated dideoxynucleotides and mass spectrometry  

UK PubMed Central (United Kingdom)

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments...Full Text Available

2001-11-01

405

Controlling Gas-Phase Reactions for Efficient Charge Reduction Electrospray Mass Spectrometry of Intact Proteins  

UK PubMed Central (United Kingdom)

Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger...Full Text Available

2005-11-01

406

Cation Involvement in Telomestatin Binding to G-Quadruplex DNA  

UK PubMed Central (United Kingdom)

The binding mode of telomestatin to G-quadruplex DNA has been investigated using electrospray mass spectrometry, by detecting the intact complexes formed in ammonium acetate. The mass measurements show...Full Text Available

407

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

408

Assessment of 1183 screen-detected, category 3B, circumscribed masses by cytology and core biopsy with long-term follow up data  

UK PubMed Central (United Kingdom)

Discrete masses are commonly detected during mammographic screening and most such lesions are benign. For lesions without pathognomonically benign imaging features that are still regarded likely to...Full Text Available

2008-04-08

409

Applications of BMI or BSI: Differences and Revisions According to Age and Height  

UK PubMed Central (United Kingdom)

Validation of body-mass relationships requires a careful statistical analysis of data of normal weight individuals. BMI (ratio between body mass and square of body height) and BSI values (ratio between...Full Text Available

2010-01-01

410

Analytical validation of accelerator mass spectrometry for pharmaceutical development  

UK PubMed Central (United Kingdom)

The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures....Full Text Available

2010-03-01

411

Accretion disks  

Science.gov (United States)

Derivations are made for the mass and the mass-turnover time scale of an accretion disk as a function of the accretion rate, the observed disk radius, the non-viscous disk radius, and two parameters. These parameters depend on the effectiveness of viscosity and tidal angular momentum loss. Application is made to DQ Herculis.

1983-01-01

412

WWF - Global Warming Capable of Sparking Mass Species Extinctions  

Science.gov (United States)

... of species extinctions in around the world if global warming continues unabated, according to a new study published ... ...

413

Transition probabilities of rotational levels in "1"7"7Ta  

International Nuclear Information System (INIS)

... capture radioisotopes energy levels excited states intermediate mass nuclei

414

The distribution of mass-to-light ratio with radius in M31 and M33  

International Nuclear Information System (INIS)

1974. Netherlands Baldwin, JE Cambridge Univ. (UK). Cavendish Lab. Reidel.;

415

Tests of New Family Gauge Symmetry  

CERN Document Server

We explore the structure of a new family gauge symmetry U(3) and show its experimental signatures to search for. U(3) gauge bosons obviate an unwelcome deviation of the charged lepton mass formula with the running masses from that with the pole masses. The current structure of this model leads to flavor number violations via exchange of extra gauge bosons. We obtain bounds on the masses of the gauge bosons from rare kaon decay searches and muonium-antimuonium oscillation searches. We propose attractive signatures at LHC and lepton colliders and discuss feasibility of their discovery.

2010-01-01

416
418

Single and binary star evolution  

International Nuclear Information System (INIS)

After presenting a general account of the observed global properties of single stars of low, intermediate, and high mass, together with their theoretical Hertzsprung-Russell diagram evolution, attention is given to the observed properties of various evolved close binaries and to an assessment of the value of comparisons between observation and crude theory in characterizing the physics of mass transfer within interacting binary systems. Detailed consideration is then undertaken of such topics as stellar evolution in globular clusters, interior star changes due to nucleosynthesis and mixing, asymptotic giant branch stars of intermediate mass, the response of white dwarfs in binary systems to mass accretion, and scenarios for binary star evolution tending toward close white dwarf pairs.

419

Phantom dark energy with varying-mass dark matter particles: acceleration and cosmic coincidence problem  

CERN Document Server

We investigate several varying-mass dark-matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.

2009-01-01

420

Nuclear spectroscopy, ch. 8  

International Nuclear Information System (INIS)

Energy level schemes are derived from gamma spectroscopy of several medium-mass deformed nuclei by studying the decay or proton and #alpha# nuclear spectroscopic data. Some new isomeric studies are established among which is the 31 y "1"7"8Hf isomeric state for which Isup(#pi#), K was determined to be 16"+, 16. A four quasi-particle configuration was assigned to this state at 2447.5 +- 2.5 KeV. Atomic masses have been calculated from various measurements and, on the basis of mass formulae extrapolated to neighboring mass regions.

421

Noncircular gas velocities and the radial dependence of mass-to-light ratio in NGC 4594 (the Sombrero Galaxy)  

International Nuclear Information System (INIS)

The mass distribution of the Sombrero Galaxy, NGC 4594, is calculated in order to investigate the suspicion that the rotational velocity of the galactic gas does not measure the circular velocity in the galaxy. It is shown that the H II rotation velocities are much less than circular in the central 35 arcsec of the galaxy, and that the suspicion is correct. Thus, the H II rotation velocities cannot be used to measure the mass distribution. The absorption-line rotation curve is used to derive the mass distribution, and it is found that the M/L ratio is nearly constant. It is concluded that the visible matter is self-gravitating at least in the central 180 arcsec. 44 references.

423

Measuring relative probability of Am-242 #beta#-decay  

International Nuclear Information System (INIS)

... americium 241 americium 242 beta decay chain reactions integral doses mass

424

Measurements and evaluations of nuclear data on actinide isotopes  

International Nuclear Information System (INIS)

The measurements of the nuclear decay of actinide isotopes and the evaluation of the radioactive properties of nuclide with the mass 242 is discussed in this paper.

1979-08-01

425

Mass: Evolving Tool of the US Operational Artist  

Science.gov (United States)

... ire examples of successive operations, as are the breakout operations GOODWOOD and COBRA. Also, for the first time, ...

1993-05-14

426

MINEQL-PC. Chemical Equilibrium Composition of Aqueous Systems  

Energy Technology Data Exchange (ETDEWEB)

MINEQL is a subroutine package to calculate equilibrium composition of an aqueous system, accounting for mass transfer.

1986-11-21

428

Decay of "1"7"7Ta to levels of "1"7"7Hf  

International Nuclear Information System (INIS)

... intermediate mass nuclei isotopes leptonic decay nuclei odd-even nuclei

1973-10-01

429

Collective model for the odd-mass transitional nucleus "1"8"7Ir  

International Nuclear Information System (INIS)

... collective model hamiltonians iridium 187 matrix elements nuclear cores

1976-06-15

430

Chiral and Continuum Extrapolation of Partially-Quenched Hadron Masses  

CERN Document Server

Using the finite-range regularisation (FRR) of chiral effective field theory, the chiral extrapolation formula for the vector meson mass is derived for the case of partially-quenched QCD. We re-analyse the dynamical fermion QCD data for the vector meson mass from the CP-PACS collaboration. A global fit, including finite lattice spacing effects, of all 16 of their ensembles is performed. We study the FRR method together with a naive polynomial approach and find excellent agreement ~1% with the experimental value of M_rho from the former approach. These results are extended to the case of the nucleon mass.

2005-01-01

432

A HREELS Investigation of Ethylene on Pt Model Catalysts  

Science.gov (United States)

... analyzer section for angle resolved measurements, and a thin film evaporator with a quartz crystal microbalance to measure the mass deposition. ...

1990-05-20

433

Quantitative spectroscopy of close binary stars  

CERN Document Server

The method of spectral disentangling has now created the opportunity for studying the chemical composition in previously inaccessible components of binary and multiple stars. This in turn makes it possible to trace their chemical evolution, a vital aspect in understanding the evolution of stellar systems. We review different ways to reconstruct individual spectra from eclipsing and non-eclipsing systems, and then concentrate on some recent applications to detached binaries with high-mass and intermediate-mass stars, and Algol-type mass-transfer systems.

2011-01-01

434

Neutron-proton mass difference in isospin-asymmetric nuclear matter  

Energy Technology Data Exchange (ETDEWEB)

Isospin-breaking effects in the baryonic sector are studied in the framework of a medium-modified Skyrme model. The neutron-proton mass difference in infinite, asymmetric nuclear matter is discussed. In order to describe the influence of the nuclear environment on the skyrmions, we include energy-dependent charged and neutral pion optical potentials in the s- and p-wave channels. The present approach predicts that the neutron-proton mass difference is mainly dictated by its strong part and that it strongly decreases in neutron matter. (orig.)

2007-06-15

435

Isotopic effects on solubility-limited mass transfer  

Energy Technology Data Exchange (ETDEWEB)

In our previous theoretical analyses, solubility-limited mass transfer from waste solids applies if a species is at a constant elemental concentration in liquid at the waste surface. For an element with isotopes that decay appreciably during the time of interest, a solubility boundary condition results in a time-dependent boundary concentration of each isotope. Here we present mass-transfer equations that include the effects of isotopic decay boundary conditions. 9 refs., 1 fig.

1989-06-01

436

Influence of rotation and magnetic field on the minimum mass of a main-sequence star  

Energy Technology Data Exchange (ETDEWEB)

The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.

1980-11-01

437

Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium  

Science.gov (United States)

Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.

1988-02-01

438

Flavor Mixing of Quarks and Neutrinos  

CERN Document Server

The "texture zero mass matrices" for the quarks and leptons describe very well the flavor mixing of the quarks and leptons. We can calculate the angles of the unitarity triangle. We expect the angle alpha of the unitarity triangle to be 90 degrees. The masses of the neutrinos can be calculated - they are very small, the largest neutrino mass is 0.05 eV. We calculated the matrix element of the mixing matrix, relevant for the reactor mixing angle. It can be measured in the near future in the DAYA BAY experiment.

2011-01-01

439

Effluent reduction using pinch technology: Targets for reduction and capital costs for mass exchange networks  

Energy Technology Data Exchange (ETDEWEB)

This paper illustrates how the techniques developed by the authors for capital cost targeting of mass exchange networks can be applied to determination of capital investment targets for reduction in effluent for existing systems involving mass exchange. The results is an impact diagram which shows the relationship between effluent reduction and capital investment, indicating a region of limiting return on investment as well as the maximum possible reduction in effluent. (au)

1999-02-01

440

Heat transfer augmentation of a circular pipe flow using nano-particle layers  

International Nuclear Information System (INIS)

For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In this paper, we adopt nano-particle layer ...

2007-10-05

441

Alloy 800 SG tubing: current status and future challenges  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio ({>=}12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those ...

2007-07-01

442

Alloy 800 SG tubing: current status and future challenges  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio (#>=#12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those that ...

2007-08-19

443

ppbar enhancement in B and J/Psi decay  

CERN Document Server

The near-threshold enhancement in the ppbar invariant mass spectrum from the B^+ -> K^+ ppbar decay reported recently by the BaBar Collaboration is studied within the J\\"ulich NNbar model. We illustrate that the invariant mass dependence of the ppbar spectrum close to the threshold can be reproduced by the final state interactions. This explanation is in line with our previous analysis of the ppbar invariant mass spectrum from the J/Psi -> gamma ppbar decay measured by the BES Collaboration. We also comment on a structure found recently in the pi^+ pi^- eta' mass spectrum of the radiative J/Psi decay by the BES Collaboration. In particular we argue that one should be rather cautions in bringing this structure in connection with the enhancement found in the ppbar invariant mass spectrum or with the existence of NNbar bound states.

2006-01-01

444

The Dissipative Merger Progenitors of Elliptical Galaxies  

CERN Document Server

We address the deviations of the scaling relations of elliptical galaxies from the expectations based on the virial theorem and homology, including the "tilt" of the "fundamental plane" and the steep decline of density with mass. We show that such tilts result from dissipative major mergers once the gas fraction available for dissipation declines with progenitor mass, and derive the scaling properties of the progenitors. We use hydrodynamical simulations to quantify the effects of major mergers with different gas fractions on the structural properties of galaxies. The tilts are driven by the differential shrinkage of the effective stellar radius as a function of dissipation in the merger, while the correlated smaller enhancements in internal velocity and stellar mass keep the slope of the velocity-stellar mass relation near V \\pr M_*^{1/4}. The progenitors match a straightforward model of disc ...

2006-01-01

445

Security features of a nuclear material accounting system  

Energy Technology Data Exchange (ETDEWEB)

The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various transaction activities in the system is controlled through the level of MASS user privilege. Details of MASS user privilege will be discussed.

1988-01-01

446

Search for Z' ---> e+ e- using dielectron mass and angular distribution  

Energy Technology Data Exchange (ETDEWEB)

The authors search Z{prime} bosons in dielectron events produced in p{bar p} collisions at {radical}s = 1.96 TeV, using a 0.45 fb{sup -1} dataset accumulated with the CDF II detector at the Fermilab Tevatron. To identify the Z{prime} {yields} e{sup +}e{sup -} signal, both the dielectron invariant mass distribution and the angular distribution of the electron pair are used. No evidence of a signal is found, and 95% confidence level lower limits are set on the Z{prime} mass for several models. Limits are also placed on the mass and gauge coupling of a generic Z{prime}, as well as on the contact interaction mass scales for different helicity structure scenarios.

2006-02-01

447

Robust curve fitting method for single binding site mass action model of radioimmunoassay  

International Nuclear Information System (INIS)

The difficulty and unstability of the parameter estimation of mass action model for radioimmunoassay are the major obstacles to its application in routine work. A unique robust curve fitting method for the mass action model was introduced. large numbers of simulated data were generated with Monte Carlo method to compare the accuracy and robustness of the robust fitting and the least squre fitting (Marquardt method) of the mass action model. The results demonstrated that the new robusst method significantly increased the accuracy and reliability of data processing with the mass action model. It also markedly reduced the influence of outliers in the fitting of RIA data, and it was always 'convergent'. This robust method could also be applied to other mathematical models which can be transformed into high degree equations and no initial estimates are needed for curve fitting.

448

On the elliptical flow and mass asymmetry of the colliding nuclei  

British Library Electronic Table of Contents (United Kingdom)

A study of elliptical flow is carried out for different mass asymmetries of colliding nuclei using the reactions of Formula Not Shown ( Formula Not Shown ), Formula Not Shown ( Formula Not Shown ) and Formula Not Shown ( Formula Not Shown ). The present reactions are simulated at incident energies between 50 and 250 MeV/nucleon within the framework of isospin-dependent quantum molecular dynamics model. For the present analysis, total mass of colliding pairs is kept fixed and mass asymmetry is varied between 0.3 and 0.7. The elliptical flow shows a transition from in-plane to out-of-plane in the mid rapidity region with incident energy. The transition energy is found to increase with the mass asymmetry for light charged particles. A good agreement is obtained with experimental measurements.

2011-01-01

449

Mass-loss in 2D zero-age main-sequence stellar models  

British Library Electronic Table of Contents (United Kingdom)

Abstract A large number of massive stars are known to rotate rapidly, resulting in a significant distortion and variation in surface temperature from the pole to the equator. Radiatively driven mass-loss is temperature-dependent, so rapid rotation produces a variation in the mass-loss and angular momentum loss rates across the surface of the star, which is expected to affect the evolution of rapidly rotating massive stars. In this work, we use zero-age main-sequence (ZAMS) stellar models to investigate the two-dimensional effects of rotation on stellar mass-loss, using two common prescriptions for radiatively driven mass-loss. The associated loss of angular momentum from these models is also considered. Using 2D stellar models, which give the variation in surface parameters as a function o...

2011-01-01

450

Mass transfer in horizontal flow channels with thermal gradients  

Energy Technology Data Exchange (ETDEWEB)

Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55{sup o}C and for non-isothermal flows with applied temperature differences up to 30{sup o}C. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)

1997-12-15

451

Mass transfer in horizontal flow channels with thermal gradients  

International Nuclear Information System (INIS)

Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55"oC and for non-isothermal flows with applied temperature differences up to 30"oC. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)

1997-12-01

452

Mass density of glassy Pd{sub 80}Si{sub 20}during low temperature light ion irradiation.  

Energy Technology Data Exchange (ETDEWEB)

Changes in mass density of amorphous Pd{sub 80}Si{sub 20} were monitored in situ during irradiation with He{sup 2+} and H{sup +} ions at temperatures below 100 K and during subsequent thermal treatment. The mass density decreased with increasing ion fluence and exponentially approached a saturation value of -1.2%, corresponding to a recombination volume of 190 atomic volumes. The initial swelling rate was 2.3 atomic volumes/displaced atom. The mass density of the irradiated material increased during subsequent thermal treatment, and the irradiation-induced decrease of the mass density recovered completely at room temperature.

2001-10-01

453

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

454

Glueball Mass Spectrum in KK Monopole Background  

CERN Document Server

We consider typeIIA supergravity solution of D2-branes and D3-branes localized within D6-branes in the near-core region of D6-branes. With these solutions we can calculate the spectrum of the glueball mass in QCD3 and QCD4. The equation of motion describing the dilaton has the same eigenvalues and the same glueball masses in QCD3 and QCD4. Glueball mass spectrum is the same in the near core region of D6-branes of their M-theory counterpart is KK monopole. We conclude that the glueball mass spectrum is the same in QCD3 and QCD4 by considering the `near-core' limit of D6-branes of which M-theory counterpart (KK monopole background) becomes an ALE space with an $A_{N-1}$ singularity times 7 dimensional Minkowski space $M^{(6,1)}$.

1999-01-01

455

Evidence for a central dark mass in NGC 4594 (the Sombrero galaxy)  

International Nuclear Information System (INIS)

This paper discusses the results of the absorption-line spectroscopy carried out with the Canada-France-Hawaii Telescope on the prototypical Sa galaxy NGC 4594 (the Sombrero galaxy). Two conclusions were derived concerning this galaxy. First, at the values of r less than 10 arcsec, there is a well-defined nuclear disk of stars which is not obviously connected to the main disk at larger radii. Second, the mass-to-light ratio, M/L(V), of the galaxy rises abruptly at r values less than 1 arcsec to values of M/L(V) greater than 50, which is at least 10 times as large as the mass-to-light ratios at r values above 2 arcsec. This implies the presence of a central dark mass of a magnitude between 10 to the 8.5th and 10 to the 9.5th solar masses. 54 references.

456

Enthalpy and mass flowrate measurements for two-phase geothermal production by Tracer dilution techniques  

Energy Technology Data Exchange (ETDEWEB)

A new technique has been developed for the measurement of steam mass flowrate, water mass flowrate and total enthalpy of two-phase fluids produced from geothermal wells. The method involves precisely metered injection of liquid and vapor phase tracers into the two-phase production pipeline and concurrent sampling of each phase downstream of the injection point. Subsequent chemical analysis of the steam and water samples for tracer content enables the calculation of mass flowrate for each phase given the known mass injection rates of tracer. This technique has now been used extensively at the Coso geothermal project, owned and operated by California Energy Company. Initial validation of the method was performed at the Roosevelt Hot Springs geothermal project on wells producing to individual production separators equipped with orificeplate flowmeters for each phase.

1993-01-28

457

Empirically Consistent Electroweak Radiative Corrections with the Two-Higgs Doublet Model  

CERN Document Server

The electroweak radiative correction, which turned out to be marginal within the standard electroweak model having the minimal Higgs sector in view of the present experimental information, fits well the experiment when the Higgs sector is extended to have two Higgs doublets. We predict the range where the charged and CP odd Higgs boson masses would lie, taking the two CP even neutral Higgs boson masses to be degenerate which makes the analysis in multiparameter space feasible. It is shown that the mass of neutral Higgs doublet boson can arbitrarily be large consistently with the $W$ mass, if the charged Higgs boson is present and it's mass lies in some appropriate ranges.

2008-01-01

458

Dynamics of the globular cluster M2 (NGC 7089)  

International Nuclear Information System (INIS)

We have obtained radial velocities for 69 stars in the globular cluster M2 (NGC 7089). M2's rotation axis is, within sizeable uncertainties, perpendicular to the major axis determined by the flattening. The ratio of rotational to random kinetic energy agrees with that predicted from the ellipticity assuming an oblate figure and an isotropic velocity-dispersion tensor. We have fitted King-Michie models to determine M2's mass, the exponent of an assumed power-law mass function, and the anisotropy radius. The most significant sources of uncertainty in the modeling are the velocity dispersion, the distance, and the mass-luminosity relation for the cluster stars. The models favor mass functions similar to or shallower than the Salpeter initial-mass function and a moderate amount of velocity anisotropy.

459

Are Stars with Planets Polluted?  

CERN Document Server

We compare the metallicities of stars with radial velocity planets to the metallicity of a sample of field dwarfs. We confirm recent work indicating that the stars-with-planet sample as a whole is iron rich. However, the lowest mass stars tend to be iron poor, with several having [Fe/H]0.48) that contributes to but does not explain the mass-metallicity trend in the stars-with-planets sample. We use Monte Carlo models to show that adding an average of 6.5 Earth masses of iron to each star can explain both the mass-metallicity and the age-metallicity relations of the stars-with-planets sample. However, for at least one star, HD 38529, there is good evidence that the bulk metallicity is high. We conclude that the observed metallicities and metallicity trends are the result of the interaction of three effects; accretion of about 6 Earth masses of iron rich material, selection effects, ...

2002-01-01

460

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

Energy Technology Data Exchange (ETDEWEB)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar ...

2006-07-01

461

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

International Nuclear Information System (INIS)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar ...

462

Light meson mass dependence of the positive-parity heavy-strange mesons  

Energy Technology Data Exchange (ETDEWEB)

We calculate the masses of the resonances D{sub s0}{sup *}(2317) and D{sub s1}(2460) as well as their bottom partners as bound states of a kaon and a D{sup (*)} - and B{sup (*)} -meson, respectively, in unitarized chiral perturbation theory at next-to-leading order. After fixing the parameters in the D{sub s0}{sup *}(2317) channel, the calculated mass for the D{sub s1}(2460) is found in excellent agreement with experiment. The masses for the analogous states with a bottom quark are predicted to be M{sub B{sup *}{sub s0}}=(5696{+-}40) MeV and M{sub B{sub s1}}=(5742{+-}40) MeV in reasonable agreement with previous analyses. In particular, we predict M{sub B{sub s1}}-M{sub B{sub s0}}{sup *}=46{+-}1 MeV. We also explore the dependence of the states on the pion and kaon masses. We argue that the kaon mass dependence of a kaonic bound state should be almost linear with slope about unity. ...

2011-02-15

463

3D transient calculations of PGV-1000 based on TRAC  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: During calculations of SAR accidents and transients it is necessary to perform steam generator simulation. Best accuracy is 3D transient calculations presented in report. Main outcomes of work was next: 1. There was shown by analysis the applicability of code TRAC (Los-Alamos laboratory) for thermal - hydraulic calculations of horizontal steam generator PGV-1000M. Special nodalization scheme was developed for it purposes. 2. Validation and selection of thermal-hydraulic correlations for improvement of using the code at calculation PGV-1000M were performed. As result Labuntsov formula is recommended for horizontal SG. 3. Calculations of nominal mode operation of PGV-1000M for cross-verification with code STEG (Electrogorsk Research and Engineering Center EREC) during its verification were performed. Solution by TRAC was obtained for transient problem after stabilization time. 4. Development of dynamic SG model as conjugate problem (thermal hydraulic of ...

2005-07-01

464

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1998-02-01

465

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam-water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two-phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 MW TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1999-11-03

466

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1998-03-16

467

Steam generator access modification and waterlance cleaning for Wolsong and other nuclear plants  

International Nuclear Information System (INIS)

Steam generators for nuclear plants require access to the primary and secondary side for various inspection, cleaning and repair procedures and upon achieving access various inspection and cleaning tasks must be carried out. Steam generators currently at manufacture are therefore provided with; primary side access via the primary manways, steam drum access via the steam drum manway, U-bend region access via the secondary manway and drum-internals access passages, tubesheet secondary side access via tubesheet level inspection ports and tube support plate access via tube support level access ports. Many CANDU steam generators were built with only primary and drum manways and either no tubesheet ports or ports which were located ineffectively. The steam generators at Wolsong 1 were built with secondary side inspection ports that provided only limited access away from the no-tube-lane. In addition they have very difficult ...

2002-05-05

468

Risk assessment of severe accident-induced steam generator tube rupture  

Energy Technology Data Exchange (ETDEWEB)

This report describes the basis, results, and related risk implications of an analysis performed by an ad hoc working group of the U.S. Nuclear Regulatory Commission (NRC) to assess the containment bypass potential attributable to steam generator tube rupture (SGTR) induced by severe accident conditions. The SGTR Severe Accident Working Group, comprised of staff members from the NRC`s Offices of Nuclear Reactor Regulation (NRR) and Nuclear Regulatory Research (RES), undertook the analysis beginning in December 1995 to support a proposed steam generator integrity rule. The work drew upon previous risk and thermal-hydraulic analyses of core damage sequences, with a focus on the Surry plant as a representative example. This analysis yielded new results, however, derived by predicting thermal-hydraulic conditions of selected severe accident scenarios using the SCDAP/RELAP5 computer code, flawed tube failure modeling, and tube ...

1998-03-01

469

Nature Of Tube Degradation In Horizontal Steam Generators  

Energy Technology Data Exchange (ETDEWEB)

Nature of tube degradation was studied in support of horizontal steam generator lifetime calculations. Experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K(ISCC), and the crack growth rate were made to predict evolution of damage in tube walls. Experimental results were compared with in-service inspections experience. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that material of SG (steam generator) tubes ...

2002-07-01

470

Nature Of Tube Degradation In Horizontal Steam Generators  

International Nuclear Information System (INIS)

Nature of tube degradation was studied in support of horizontal steam generator lifetime calculations. Experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K(ISCC), and the crack growth rate were made to predict evolution of damage in tube walls. Experimental results were compared with in-service inspections experience. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that material of SG (steam generator) tubes ...

2002-09-23

471

Extreme embrittlement of austenitic stainless steel irradiated to 75--81 dpa at 335--360 C  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of an experiment conducted in the BN-350 fast reactor in Kazakhstan that involved the irradiation of argon-pressurized thin-walled tubes (0--2000 MPa hoop stress) constructed from Fe-16Cr-15Ni-3Mo-Nb stabilized steel in contact with the sodium coolant, which enters the reactor at {approximately}270 C. Tubes in the annealed condition reached 75 dpa at 335 C, and another set in the 20% cold-worked condition reached 81 dpa at 360 C. Upon disassembly all tubes, except those in the stress-free condition, were found to have failed in an extremely brittle fashion. The stress-free tubes exhibited diameter changes that imply swelling levels ranging from 9 to 16%. It is expected that stress-enhancement of swelling induced even larger swelling levels in the stressed tubes. The embrittlement is explained in terms of the sensitivity of the swelling regime to ...

1998-03-01

472

Experiences in radioactive gaseous effluent management in JAERI  

International Nuclear Information System (INIS)

In the Japan Research Reactor-II (JRR-2), the main source of _4_1Ar generation is the exhaust air from the horizontal experimental holes and the pneumatic tubes. For the horizontal experimental holes, the flow of exhaust air through the holes was decreased by improving the airtightness, and a decay duct of capacity 2.4 m_3 was installed in the middle of the exhaust line. In consequence, the release rate of _4_1Ar was reduced by 6-8%. For the pneumatic tubes, a mechanical shutter was installed in the tube. The shutter stops the exhaust air flow, except when the pneumatic tube is used. Prior to the use, the activated air in the tube is led to a decay tank. As a result, the _4_1Ar release rate was reduced by 10-20%. By the above means, the yearly exposure at the site boundary was reduced to 0.36 mR from 2.6 mR. In Hot Laboratory for metallurgical examination of spent fuel, the exhaust ...

1983-05-01

473

Evaluation of new corrosion resistant superheater tubings in high efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

In order to develop new corrosion resistant superheater tubes capable of functioning efficiency under temperature and pressure conditions of 500 C and 100 ata used in high efficient waste-to-energy (WTE) plants, field corrosion tests were conducted on eight single tube materials and two welded overlay materials at metal temperatures of 450 C and 550 C for 700 and 3,000 hours, respectively, in three typical japanese waste incineration plants. The test results indicate that austenitic alloys containing higher concentrations of [Cr + Ni + Mo] show excellent corrosion resistant properties and new alloys of JHN24 and HR30M have good corrosion resistance. The different corrosion rate found for each of the three plants could be explained by differences in the severity of corrosion factors, such as, gas temperature, concentration of molten salts due to Cl content of deposits, and heavy metal [ZnO + PbO] content etc. It was also confirmed that the ...

1997-08-01

474

Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66{approx}8.91 x 1025 n/m{sup 2}) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4{approx}6 times faster DHC velocity(5.298E-0.8{approx}7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen DHC fracture ...

2003-10-01

475

Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube  

International Nuclear Information System (INIS)

The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66#approx#8.91 x 1025 n/m"2) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4#approx#6 times faster DHC velocity(5.298E-0.8#approx#7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen DHC fracture surface ...

2003-10-01

476

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support area are congested. And also, workers involved in inspecting ...

2000-07-01

477

Comparison of steam-generator liquid holdup and core uncovery in two facilities of differing scale  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on Run SB-CL-05, a test similar to Semiscale Run S-UT-8. The test results show that the core was uncovered briefly during the accident and that the rods overheated at certain core locations. Liquid holdup on the upflow side of the steam-generator tubes was observed. After the loop seal cleared, the core refilled and the rods cooled. These behaviors were similar to those observed in the Semiscale run. The Large-Scale Test Facility (LSTF) Run SB-CL-06 is a counterpart test to Semiscale Run S-LH-01. The comparison of the results of both tests shows similar phenomena. The similarity of phenomena in these two facilities build confidence that these results can be expected to occur in a PWR. Similar holdup has now been observed in the 6 tubes of Semiscale and in the 141 tubes of LSTF. It is now more believable that holdup may occur in a full-scale steam generator with 3000 or more tubes. ...

1987-01-01

478

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results of void fraction in ...

1993-06-01

479

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results of void ...

1994-07-01

480

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results of void fraction in ...

1993-01-01

481

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer  

International Nuclear Information System (INIS)

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the "6"3"-"6"6Fe and "6"4"-"6"7Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for "6"6Fe and "6"7Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of "6"5Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in "6"7Co is confirmed. Relative mass uncertainties as low as 4x10"-"8 are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of "6"4Co, where a 5#sigma# deviation is ...

2010-04-01

482

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to ...

2006-12-21

483

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle is just above the ...

2006-11-13

484

Theoretical simulation of SDS - 2 actuation in 540 MWe PHWR  

International Nuclear Information System (INIS)

The 540 MWe PHWR has two fully independent shutdown systems. The first shutdown system (SDS-1) comprises of 28 spring assisted, vertical gravity drop shut-off rods, each consisting of a cadmium absorber sandwiched between stainless steel tubes. The second shutdown system (SDS-2) constitutes six poison tanks connected to respective zircaloy injection tubes. This system is capable of high speed injection of gadolinium nitrate solution (in D2O) into the moderator through these tubes. Theoretical estimation was carried out at different injection pressures and different concentration of gadolinium nitrate solution to arrive at the limiting value of these parameters from reactivity consideration point of view. The plant measurements of SDS-2 actuations at 60 and 80 Kg/cm2 pressure of helium was used to validate and upgrade the estimation model. The paper gives the details of the validation details of SDS-2 actuation. (author)

2006-11-13

485

Separation of Minor Actinides and Lanthanides with Carbon Nano-materials  

Energy Technology Data Exchange (ETDEWEB)

Recently we have found that carbon nano-materials have ability to recognize softer actinides(III). In this presentation, separation of americium(III) from lanthanides(III) by chromatography with carbon nano-materials, such as carbon nano-tubes and graphite, has been investigated by batch adsorption experiments and chromatography. The separation factor (SF) between americium(III) and lanthanide(III) was about 2 in the range of pH from 1 to 4 by using carbon nano-tube, graphite and activated charcoal. The separation factor depended on the diameter of carbon nano-tubes. Smaller one, 3-20 nm diameter, showed the best selectivity for americium(III), which separation factor was about 2.0, although larger one, 40-70 nm, showed almost no selectivity. The same behavior has been observed by using graphite powder and activated charcoal although acid- or alkali pretreated activated charcoal which generally has acidic functional group ...

2009-06-15

486

Relaxation and corrosion resistance of alloy 800 used for steam generator tubes of ship borne boilers  

Energy Technology Data Exchange (ETDEWEB)

The INCO ``INCOLOY 800`` trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heat exchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by electrochemistry in pressurized hot water. (authors). 4 figs., 5 ...

1994-12-31

487

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the feedback signal and the ...

1993-12-01

488

Modeling of boiling- and tow-phase flow in offset-strip-fin heat-exchanger geometries  

Energy Technology Data Exchange (ETDEWEB)

The two-phase heat-transfer and pressure-drop characteristics of offset-strip-fin heat-exchanger geometries are examined using both experimental and analytical modeling techniques. Newly-obtained boiling-flow heat-transfer data are presented for two large-scale offset fin geometries at low-to-moderate wall-superheat conditions. Data for which nucleate boiling appeared to be completely suppressed were analyzed together with similar results for other offset fin surfaces to study the effects of channel dimensions on the convective evaporation component of the local heat transfer coefficient. Although these data were found to be well correlated in terms of modified forms of the F and Martinelli parameters used in previous studies of round-tube flows, a single F-factor correlation valid for all combinations of fin and channel dimensions did not appear to exist. The two-phase pressure-drop characteristics of offset-fin surfaces were found to be much different than those ...

1988-01-01

489

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous ...

1993-01-01

490

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

International Nuclear Information System (INIS)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-07-06

491

Heat transfer augmentation in a heat exchanger tube using a baffle  

International Nuclear Information System (INIS)

Heat transfer enhancement in a heat exchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat transfer. The results show that the average Nusselt number for the two baffles case ...

2007-04-01

492

Heat transfer augmentation for external ice-on-tube TES systems using porous copper mesh to increase volumetric ice production  

Energy Technology Data Exchange (ETDEWEB)

Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully controlled experiments. This study shows that ice volume increase between 50 and 90% is possible by using HCEDs of the type tested. (author)

2006-09-15

493

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that coiled wire turbulence promoters are more effective at Reynolds ...

1992-12-01

494

Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with regularly spaced helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with full-length helical screw element of different twist ratio, and helical screw inserts with spacer length 100, 200, 300 and 400mm have been studied with uniform heat flux under laminar flow condition. The experimental data obtained are verified with those obtained from plain tube published data. The effect of spacer length on heat transfer augmentation and friction factor, and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The decrease in Nusselt number for the helical twist with spacer length is within 10% for each subsequent 100mm increase in spacer length. The decrease in friction factor is nearly two times lower than the full length helical twist at low Reynolds number, and four times lower than the full length helical twist at high Reynolds number for all twist ratio. The ...

2007-02-15

495

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage ...

2003-01-01

496

Design and strength evaluation of structural joint made by electro-magnetic forming (EMF)  

International Nuclear Information System (INIS)

Recently, weight reduction of vehicles has been of great interest, and consequently, the use of low-density materials in the automotive industry is increasing every year. Materials should not be substituted such a way that material of component parts is simply changed because there is a problem in achieving stiffness and strength. To achieve these requirements, the automobile should be redesigned totally. Aluminum spaceframe is rapidly being adopted as a body structure for accommodating lightness, stiffness and strength requirement. In aluminum spaceframe manufacturing, it is often required to join aluminum tube. But there are few suitable methods for joining aluminum tube, so that much interest has been focused on testing suitable joining methods. Joining by electromagnetic forming(EMF) can be useful method in joining aluminum tube, which offers some advantages compared with the conventional joining method. In this paper, ...

2004-06-10

497

Corrosion resistant coatings for silicon carbide heat exchanger tubes -- Volume 3. Final report  

Energy Technology Data Exchange (ETDEWEB)

The development of a silicon carbide (SiC) heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. This demanding set of technical performance and ...

1996-06-07

498

Analysis of thermal hydraulics and soluble impurity distribution in horizontal steam generator PGV-1000 with STEG code  

International Nuclear Information System (INIS)

The 3D modeling of the thermal hydraulic processes and soluble impurity distribution in the horizontal steam generator PGV-1000 was fulfilled with the thermal hydraulic code STEG. Steady-state operation of horizontal seam generator PGV-1000 was analyzed at nominal power. The modeling of the soluble impurity distribution was fulfilled on the basis of the previous thermal hydraulic modeling results. The processes of the soluble impurity deposition on the steam generator tube bundles and deposits outwash were considered in the mathematical model of the code. The modeling was fulfilled for horizontal steam generators with different peculiarities in construction. Calculation results were compared with experimental results obtained at NPP. The agreement between calculated and experimental results is quite reasonable. Results of modeling are sensible to the peculiarities of the horizontal steam generator construction and consideration of these peculiarities in calculation ...

2003-04-20

499

Air-side performance of a parallel-flow parallel-fin (PF{sup 2}) heat exchanger in sequential frosting  

Energy Technology Data Exchange (ETDEWEB)

The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat exchanger and overall heat transfer coefficient are quantified under frost conditions as functions of the air humidity and air face velocity. The performances of two types ...

2010-09-15