WorldWideScience
 
 
2

Heat transfer equipment performance diagnosis of auxiliary systems in electric power stations; Diagnostico de comportamiento de equipo de transferencia de calor de sistemas auxiliares de centrales termoelectricas  

Energy Technology Data Exchange (ETDEWEB)

In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de Electricidad has on hand a prompt access to them in ...

1990-12-31

3

Some aspects for structure selection; Algunas consideraciones para seleccionar una estructura  

Energy Technology Data Exchange (ETDEWEB)

This paper shows some considerations about the cost of wood, steel and cement support pillars in rural power distribution systems. The life span, mechanical properties, cost estimation and general durability of each type of pillar was evaluated, aiming a better selection of the desired one. 6 figs., 8 tabs., 4 refs.

1986-12-31

4

Subsidence monitoring in the Cerro Prieto geothermal field, B.C., Mexico; Monitoreo de la subsidencia en el campo geotermico de Cerro Prieto, B.C., Mexico  

Energy Technology Data Exchange (ETDEWEB)

Since 1977, precise leveling surveys have been carried out to determine whether there have been vertical terrain displacements and the subsidence speed rate in the Cerro Prieto Geothermal field area. The elevation contours for each leveling show since 1962 that there was a basin that involves the geothermal field. The differences in the last three levelings show a generalized subsidence between Cerro Prieto (BN 10049) and Imperial faults (BN CD-14). [Spanish] A partir de 1977 se realizan trabajos de nivelacion de precision, con el fin de conocer si existen desplazamientos verticales del terreno y cual es la velocidad de subsidencia que existe en el area del Campo Geotermico de Cerro Prieto. Las configuraciones de cotas para cada uno de los anos nivelados, muestran que desde 1962 existe una cuenca que incluye al campo geotermico; la diferencia de cotas obtenidas en las tres ultimas nivelaciones, indican una subsidencia generalizada entre la Falla Cerro Prieto (BN ...

1999-04-01

5

Fifteen years of seismic monitoring at the Las Tres Virgenes, BCS, geothermal field; Quince anos de monitoreo sismico en el campo geotermico de Las Tres Virgenes, BCS  

Energy Technology Data Exchange (ETDEWEB)

Seismic monitoring at the Las Tres Virgenes, BCS, geothermal field started in 1992 with an analog station of vertical components detecting a large number of earthquakes of varying magnitudes. In February 1993, a seismic network was installed, composed of six digital stations DR-2000-with S-6000 and S-5000 sensors and three registration channels (N-S, E-W and vertical). This was the basis for the development of a program to correct arrival-time data for P and S waves due to instrument drift. From January to April 1994 and May to August 1995, based on the 170 seismic events recorded, a velocity model was proposed. From December 1995 to July 1996, seismic data were processed and interpreted, and zones of occurrence were determined for events according to magnitude and the predominant noise in the field. From September 2003 to December 2004, 10 seismic stations (permanent and temporary) were installed and monitored and it was concluded the most active fault system was El Volcan. From ...

2009-07-15

6

Softwood forest thinning as a biomass source for ethanol production: A feasibility study for California  

Energy Technology Data Exchange (ETDEWEB)

A plan has been put forth to strategically thin northern California forests to reduce fire danger and improve forest health. The resulting biomass residue, instead of being open burned, can be converted into ethanol that can be used as a fuel oxygenate or an octane enhancer. Economic potential for a biomass-to-ethanol facility using this softwood biomass was evaluated for two cases: Stand-alone and co-located. The co-located case refers to a specific site with an existing biomass power facility owned by Wheelabrator Environmental Systems Inc. near Martell, California. A two-stage dilute acid hydrolysis process is used for the production of ethanol from softwoods, and the residual lignin is used to generate steam and electricity. For a plant processing 800 dry tonnes per day of feedstock, the co-located case is an economically attractive concept. Total estimated capital investment is approximately $ 70 million for the co-located case. The resulting internal rate of return is about 24% ...

2000-07-01

7

Conservative treatment of choroidal melanomas using iodine brachytherapy; Tratamento conservador ocular dos melanomas de coroide com braquiterapia utilizando placas de Iodo-125  

Energy Technology Data Exchange (ETDEWEB)

Objective: To retrospectively evaluate the results of conservative therapy using escorpal iodine-125 (model 6711, Amershan) plaque for brachytherapy of choroidal melanoma. Materials And Methods: We evaluated 49 patients with choroidal melanoma treated at 'Hospital do Cancer', Sao Paulo, Brazil, from March 2001 to January 2003. The following clinical parameters were analyzed and correlated with local control and survival rate: gender, age, lesion dimension, treatment duration, as well as doses in apex and base of the tumors. Results: The maximum diameter and height of the base of the tumors treated were 17 mm and 12 mm, respectively. Doses at those points ranged from 213 to 463 Gy (median: 347 Gy) and 51 to 250 Gy (median: 91 Gy), respectively. The actuarial rates of ocular preservation, disease free survival and ocular preservation in 2-years were 96%, 93.5% and 96.3%, respectively. A tumor height < 6 mm was the only predictive factor for local control (p = ...

2004-08-01

8

Importance of the planning activities, cutting, handling and analysis of the nuclei of oil well drilling; Importancia de las actividades de planificacion, corte, manejo y analisis de los nucleos de perforacion de pozos petroleros  

Energy Technology Data Exchange (ETDEWEB)

In the geologic formation where the oil deposits are located, diverse types of rocks perform functions as structural elements, storage containers for hydrocarbon water and calorific energy, as well as impermeable barriers and transport means of the energy and the fluids. Among the most important properties that are used to describe these functions are the porosity, the permeability, the compressibility of the pores volume, the formation resistivity factor, the saturation exponent, the velocity of acoustic waves P and S, the relative permeability, the capillary pressures, the elastic constants and other mechanical properties, the thermal expansion, coefficient, the thermal conductivity, the thermal diffusivity and the specific heat. The execution of an ample variety of activities related to the stages of exploration, location, evaluation and development of the oil deposits, depends strongly on having a good knowledge of the magnitude and the spatial variability of these properties. The ...

2007-07-01

9

New technology for the emulsification of petroleum residuals in water; Nueva tecnologia para la emulsificacion de residuales del petroleo en agua  

Energy Technology Data Exchange (ETDEWEB)

It turns out of interest to Comision Federal de Electricidad and Petroleos Mexicanos to reduce costs of fuel oil, reducing the viscosity of the residues petroleum of high vacuum distillation emulsifying these with water. The parameters that define the characteristics of the emulsions are mainly the relation of their components, viscosity, size and drop distribution and its stability. The experimental work began producing emulsions in form of lots, using samples of approximately 500 milliliters of vacuum residue. In this first stage, at different concentrations, were examined eight different surfactants, as well as combinations among them, also seven different stabilizers were used. With these tests it has been managed to identify the concentrations, as well as the most adequate relations of surfactants and stabilizers for the production of emulsions of vacuum residues in water. The size and drop distribution has been determined by means of an optical LEICA microscope, model DMLS, that ...

2001-07-01