A technology for removal of undissolved impurities from a horizontal steam generator using purge water is developed on the basis of a theoretical analysis. A purge with a maximal flow rate is drawn off from the zone with the highest accumulation of sludge in the lower part of the steam generator after the main circulation pump of the corresponding loop is shut off and the temperatures of the heat transfer medium at the inlet and outlet of the steam generator have equilibrated. An improved purge configuration is used for this technology; it employs shutoff and regulator valves, periodic purge lines separated by a cutoff fixture, and a D y 100 drain union as a connector for the periodic purge. Field tests show that the efficiency of this technology for sludge removal by purge water is severa...
Since 1977, precise leveling surveys have been carried out to determine whether there have been vertical terrain displacements and the subsidence speed rate in the Cerro Prieto Geothermal field area. The elevation contours for each leveling show since 1962 that there was a basin that involves the geothermal field. The differences in the last three levelings show a generalized subsidence between Cerro Prieto (BN 10049) and Imperial faults (BN CD-14). [Spanish] A partir de 1977 se realizan trabajos de nivelacion de precision, con el fin de conocer si existen desplazamientos verticales del terreno y cual es la velocidad de subsidencia que existe en el area del Campo Geotermico de Cerro Prieto. Las configuraciones de cotas para cada uno de los anos nivelados, muestran que desde 1962 existe una cuenca que incluye al campo geotermico; la diferencia de cotas obtenidas en las tres ultimas nivelaciones, indican una subsidencia generalizada entre la Falla Cerro Prieto (BN ...
Seismic monitoring at the Las Tres Virgenes, BCS, geothermal field started in 1992 with an analog station of vertical components detecting a large number of earthquakes of varying magnitudes. In February 1993, a seismic network was installed, composed of six digital stations DR-2000-with S-6000 and S-5000 sensors and three registration channels (N-S, E-W and vertical). This was the basis for the development of a program to correct arrival-time data for P and S waves due to instrument drift. From January to April 1994 and May to August 1995, based on the 170 seismic events recorded, a velocity model was proposed. From December 1995 to July 1996, seismic data were processed and interpreted, and zones of occurrence were determined for events according to magnitude and the predominant noise in the field. From September 2003 to December 2004, 10 seismic stations (permanent and temporary) were installed and monitored and it was concluded the most active fault system was El Volcan. From ...
In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de Electricidad has on hand a prompt access to them in ...