ObjectiveThe aim of this study was to ascertain whether all cervical cancer patients who received adjuvant concurrent chemoradiation (CCRT) for high risk of treatment failure after...Full Text Available
Synthetic atrial natriuretic peptide (carperitide) and B-type natriuretic peptide (BNP; nesiritide) are used to treat congestive heart failure. However, despite beneficial cardiac unloading properties, reductions in renal perfusion pressures limit their clinical effectiveness. Recently, CD-NP, a chimeric peptide composed of C-type natriuretic peptide (CNP) fused to the C-terminal tail of Dendroaspis natriuretic peptide (DNP), was shown to be more glomerular filtration rate-enhancing than BNP in dogs. However, the molecular basis for the increased responsiveness was not determined. Here, we show that the DNP tail has a striking effect on CNP, converting it from a non-agonist to a partial agonist of natriuretic peptide receptor (NPR)-A while maintaining the ability to activate NPR-B. This effect is specific for human receptors because CD-NP was only a slightly better activator of rat NPR-A due to the promiscuous nature of CNP in this species. ...
Designer natriuretic peptides (NPs) represent an active area of drug development. In canine and human studies, the designer natriuretic peptide CD-NP demonstrated more desirable therapeutic potential than recombinant B-type NP (BNP), which is known as nesiritide and is approved for treatment of acute decompensated heart failure. However, why CD-NP is more effective than BNP is not known. We previously reported that CD-NP is a poorer activator of human guanylyl cyclase-A (GC-A) and a better activator of human guanylyl cyclase-B than BNP. Here, guanylyl cyclase bioassays were used to compare the susceptibility of CD-NP verses ANP, BNP, CNP and DNP to inactivation by human kidney membranes. The half time (t(1/2)) for CD-NP inactivation was increased by factors of 13, 3 and 4 compared to ANP, BNP and CNP, respectively, when measured in the same assay. Surprisingly, DNP failed to undergo complete inactivation and was the most degradation resistant ...
The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal power plant. This Technical Note reports the results of an initial investigation that identifies the cause as having been their thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.
Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.
This review briefly discusses the clinical and basic science rationale for vagus nerve stimulation (VNS) in treatment-resistant depression (TRD). As the number of treatment failures for depression increases, the likelihood of achieving remission during acute treatment decreases, and the risk of relapse increases with the number of treatment failures. Two open trials of adjunctive VNS for TRD showed positive acute results and a growing benefit over time. The results of the acute randomized controlled trial were not significant for the primary outcome (response by HRSD-24), but the secondary measure (IDS-SR-30) was significant for VNS. A 12-month nonrandomized comparative analysis of patients receiving adjunctive VNS with TRD patients receiving treatment as usual showed significant results f...
Statement of problem Porcelain fracture associated with an implant-supported, metal ceramic crown or fixed partial denture occurs at a higher rate than in tooth-supported restorations, according to the literature. Implant-specific and patient-specific causes of ceramic failure have not been fully evaluated. Purpose The purpose of this retrospective study was to evaluate the potential statistical predictors for porcelain fracture of implant-supported, metal ceramic restorations. Material and Methods Over a 6-month period, a consecutive series of patients having previously received implant-supported, metal ceramic fixed restorations were examined during periodic recall appointments. The number of supporting implants, number of dental units, type of restoration, date of prosthesis insertion, ...
1 Measurements of the binding of 12-alpha-[3H]-digoxin to the membranes of intact erythrocytes, erythrocytic 86rubidium uptake and intraerythrocytic sodium concentrations have been made in the red cells...Full Text Available
Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.
The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the tube. This band was up to five times thicker than the oxide elsewhere in the tube. All ...
Patients with end stage renal failure (ESRD) require renal replacement therapy in the form of dialysis or renal transplantation. There is an increasing number of people receiving maintenance dialysis as patients with ESRD are increasing faster than the supply of transplantable organs. The mortality rate on dialysis is 4-6 times that of the general population and is substantially reduced by transplantation. For the past 8 years, dialysis research has focused on improving patient outcomes and quality of life on dialysis. This review examines recent advances in haemodialysis and peritoneal dialysis in a historical context and considers future research possibilities. PMID:19329705
Purpose: To evaluate the outcomes of patients with Ewing's sarcoma family of tumors (ESFT) treated with modern radiotherapy techniques with MRI along with optimal chemotherapy. Methods and Materials: The records of all 60 patients with ESFT who received radiation to the primary site between 1990 and 2004 were reviewed. All patients received chemotherapy, including vincristine, doxorubicin, cyclophosphamide, ifosfamide, and etoposide. Radiation was used as the sole modality for local control in 31 patients and was given either before (n = 3) or after surgical resection (n = 26) in the remainder. All patients had MRI and CT scan-based treatment planning, and 43% received intensity-modulated radiation therapy. Radiation doses ranged from 30 Gy to 60 Gy (median, 51 Gy), and 35% received hyperfractionated radiotherapy. Results: Median age was 16 years (range, 2-40 years). Because of selection bias for ...
Purpose: To evaluate the effect of low-dose radiation therapy and surgery on local control in patients with Ewing's Sarcoma. Materials and Methods: Between 1979 and 1995 24 patients (ages 4-47) with Ewing's sarcoma were treated with combined modality therapy that included multi agent chemotherapy, surgical resection, and radiation therapy. Twelve patients had metastatic disease at the time of presentation (pleura = 3, lung = 5, bone 4). Tumor location was central in 16 and peripheral in 8. Multi agent chemotherapy consisted of vincristine/actinomycin D/cyclophosphamide/doxorubicin in 19. The same agents with the addition of ifosfamide and etoposide were given in 5. The extent of resection was considered to be radical in 14 and of the 16 patients who received preoperative chemotherapy, 5 were found to have a pathologic complete response. All patients with lung metastases at diagnosis received whole-lung irradiation to 1400 cGy in 10 fractions. ...
The feasibility of using desferrioxamine (DF), an iron chelator, as a therapeutic agent against paraquat (PQ/sup + +/) toxicity in male Sprague-Dawley rats was explored, based on the rationale of limiting toxic hydroxyl radical production from hydrogen peroxide by removing redox-active iron. Body weights, mortality, and lung histopathology were followed for periods up to 14 days after intraperitoneal injection of PQ/sup + +/ (20 or 25 mg/kg body weight) with or without concurrent daily subcutaneous injections of DF (300 mg/day). Animals receiving PQ/sup + +/ showed the expected typical patterns of mortality and of lung histopathology, namely: marked edema, subpleural hemorrhage, acute inflammation, perivascular mononuclear cell infiltrates, sloughing of alveolar and bronchiolar lining cells, and diffuse interstitial fibrosis. Desferrioxamine alone was non-toxic. Surprisingly, results when both PQ/sup + +/ and DF were administered indicated a ...
To determine the accuracy of the intra-articular location of hyaluronic acid injection using a blind approach and to establish the usefulness of fluoroscopy-guided intra-articular injection. A fluoroscopy unit was used for 368 intra-articular injections of hyaluronic acid to 93 knees in 65 patients. Initially, blind needle positioning was conducted on the fluoroscopy table. The failure rate of the blind approach among the 368 injections was evaluated, and a relationship between the Kellgren-Lawrence grade (K-L grade) and the incidence of repeated failures using the blind approach was determined for injections to 52 knees in 37 patients who received a complete cycle of injections (five consecutive injections with a one-week interval between injections). Using a blind approach, 298 of 368 trials (81.2%) resulted in a needle tip being placed in an intra-articular location, while 70 of 368 trials resulted in an extra-articular ...
The risk of cyber attacks on process control networks (PCN) is receiving significant attention due to the potentially catastrophic extent to which PCN failures can damage the infrastructures and commodity flows that they support. Risk management addresses the coupled problems of (1) reducing the likelihood that cyber attacks would succeed in disrupting PCN operation and (2) reducing the severity of consequences in the event of PCN failure or manipulation. The Network Security Risk Model (NSRM) developed in this article provides a means of evaluating the efficacy of candidate risk management policies by modeling the baseline risk and assessing expectations of risk after the implementation of candidate measures. Where existing risk models fall short of providing adequate insight into the efficacy of candidate risk management policies due to shortcomings in their structure or formulation, the NSRM provides model structure and ...
Purpose To evaluate disease failure patterns and overall survival (OS) of women with triple-negative (TN) breast cancer who underwent breast-conserving therapy (BCT) and to understand the relationship of TN tumors with other prognostic factors. Patients and Methods The Surveillance, Epidemiology, and End Results (SEER) registry identified 562 women diagnosed and/or treated with unilateral invasive breast cancer during 2003?2004 at three Emory hospitals. After medical record review, 193 eligible women, with all tumor types, received BCT. Primary endpoints (local, regional, and distant recurrences) and secondary endpoint (OS) were evaluated using chi-square tests and Cox proportional hazards models. Results Of the 193 women, 33 (17.1%) had TN tumors and 160 (82.9%) had non-TN tumors. Patient...
Energy consumption is a perennial issue in the design of wireless sensor networks (WSNs) which typically rely on portable sources like batteries for power. Recent advances in ambient energy harvesting technology have made it a potential and promising alternative source of energy for powering WSNs. By using energy harvesters with supercapacitors, WSNs are able to operate perpetually until hardware failure and in places where batteries are hard or impossible to replace. In this paper, we study the performance of different medium access control (MAC) schemes based on CSMA and polling techniques for WSNs which are solely powered by ambient energy harvesting using energy harvesters. We base the study on (i) network throughput (S), which is the rate of sensor data received by the sink, (ii) fair...
Known since ancient times, the phenomenon of allelopathy has recently received greater attention from researchers and farmers worldwide. Crop failures and low yields caused by the reseeding, overseeding, crop rotation and replanting of fruit trees in orchards are believed to be caused by allelopathic activity. Moreover, the expensive and environmentally impacting herbicides for weed control have motivated studies directed at developing cheaper, environmentally-friendly alternatives. Despite the difficulties in separating chemical interference from other mechanisms, more modern approaches have produced consistent and conclusive data on this topic. The release and dynamics of allelochemicals in the soil are discussed herein. Examples of allelopathic crops, the allelochemicals produced and th...
Abstract Aims To determine, in the context of a trial in which counseling did not improve smoking cessation outcomes, whether this was due to a failure of the conceptual theory identifying treatment targets or the action theory specifying interventions. Design Data from a randomized clinical trial of smoking cessation counseling and bupropion SR were submitted to multi level modeling to test whether counseling influenced real time reports of cognitions, emotions and behaviors, and whether these targets predicted abstinence. Setting Center for Tobacco Research and Intervention, Madison, WI. Participants A total of 403 adult, daily smokers without contraindications to bupropion SR use. Participants were assigned randomly to receive individual counseling or no counseling and a 9 week course o...
An observational cohort study was conducted to compare the performance of the RIFLE (risk, injury, failure, loss and end-stage kidney disease), AKIN (acute kidney injury network) and conventional graded criteria to identify acute kidney injury (AKI) following SCT and to predict long-term mortality in 141 myeloablative allogeneic SCT (m-allo), 60 non-myeloablative allogeneic SCT (nm-allo) and 48 autologous SCT (auto) cases. The AKIN criteria had less ability to identify patients as having the lowest category, stage 1 (analogous to RIFLE risk): 33% (37%) in m-allo, 23% (32%) in nm-allo and 8.3% (16.7%) in auto. Cox regression showed that categories higher than the intermediate stage were independent predictors of mortality in all three definitions. The areas under receiver operating characte...
Purpose: The occurrence of extraosseous Ewing's sarcoma (ES) in deep soft tissues has been well described, but cases in which this tumor occurs in a primary cutaneous or subcutaneous site have rarely been reported. The superficial variant may be less aggressive than are the more common bony and deep soft tissue counterparts with an apparently favorable outcome. A retrospective review of patients with cutaneous or subcutaneous ES was conducted to analyze outcome and patterns of failure. Methods and Materials: Between July 1985 and March 1997, 14 patients with cutaneous or subcutaneous ES were treated at St. Jude Children's Research Hospital. The median age at presentation was 16 years (range 7-21 years). Anatomic locations included trunk and pelvis (7), upper or lower extremity (4), and head and neck (3). The median size of the lesion was 3 cm (range, 1-12 cm). Thirteen had definitive surgical resections, and one had biopsy of the mass at the time of referral. They ...
Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to receive SF, whole bone radiation to 39.6 Gy plus a 16.2 Gy boost ...
Background: Determinants of warfarin use and anticoagulation levels in atrial fibrillation (AF) patients have not been clarified thoroughly. Methods and Results: A total of 6,324 patients with non-valvular AF and congestive heart failure, hypertension, age, diabetes, prior stroke (CHADS(2)) score ?1 were used to investigate determinants of warfarin use, and 6,932 patients with AF receiving warfarin were used to investigate determinants of international normalized ratio (INR) of prothrombin time. Target INR levels for non-valvular AF patients were 1.6-2.6 for patients aged ?70 years and 2-3 for patients aged transient ischemic attack (TIA), and had higher CHADS(2) scores than those not receiving warfarin. Determinants of warfarin use were age (?60 years), AF type (persistent and permanent), and comorbidities (congestive heart failure, diabetes mellitus, and prior stroke or TIA). Use of antiplatelet drugs ...
Purpose: Extrahepatic cholangiocarcinoma is a rare malignancy. Despite radical resection, survival remains poor, with high rates of local and distant failure. To clarify the role of radiotherapy with chemotherapy, we performed a retrospective analysis of resected patients who had undergone chemoradiotherapy. Methods and Materials: A total of 45 patients (13 with proximal and 32 with distal disease) underwent resection plus radiotherapy (median dose, 50.4 Gy). All but 1 patient received concurrent fluoropyrimidine-based chemotherapy. The median follow-up was 30 months for all patients and 40 months for survivors. Results: Of the 45 patients, 33 underwent adjuvant radiotherapy, and 12 were treated neoadjuvantly. The 5-year actuarial overall survival, disease-free survival, metastasis-free survival, and locoregional control rates were 33%, 37%, 42%, and 78%, respectively. The median survival was 34 months. No patient died perioperatively. Patient ...
Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event free (EFS) and overall survival rates from multi-disciplinary therapy in Ewing's Sarcoma (ES). Materials and Methods: Between 1983 and 1988, 184 children with ES were enrolled onto POG 8346. 178 (97%) met eligibility criteria; 6 had non-ES pathology. Induction treatment of Cyclophosphamide/Adriamycin (C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy (XRT) and C/A, Dactinomycin and Vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. 40 patients were randomized to receive SF, whole bone XRT to 39.6 Gy plus a 16.2 Gy boost (total 55.8 Gy) or IF to 55.8 Gy while 84 were assigned to IF XRT. Results: Of 179 eligible patients, ...
Purpose : To evaluate whether the early pulmonary irradiation can prevent or decrease the pulmonary damage and contribute to improve ultimate survival in paraquat lung. Materials and Methods : From Jun. 1987 to Aug. 1993, thirty patients with paraquat poisoning were evaluated. Fourteen of these patients were received pulmonary irradiation(RT). All of the patients ere managed with aggressive supportive treatment such as gastric lavage, forced diuresis, antioxidant agents and antifibrosis agents. Ingested amounts of paraquat were estimated into three groups(A: minimal < about 5cc, B: mouthful 5-50 cc, C: Large > 50cc). Pulmonary irradiation was started within 24 hours after admission(from day 1 to day 11 after ingestion of paraquat). Both whole lungs were irradiated with AP/PA parallel opposing fields using C0-60 teletherapy machine. A total of 10Gy(2Gy/fr. X 5 days)was delivered without correction of lung density. Results : In group A, all patients ...
Objective was to present our 8 year experience in the prevention of the obturator nerve reflex during transurethral resection of bladder tumors. This study was performed in Ataturk University Hospital between 1999 and 2007. We retrospectively reviewed the records of 89 patients with inferolateral bladder tumors, who underwent transurethral resection under epidural or general anesthesia and requested obturator nerve reflex inhibition. Epidural anesthesia was administered to 57 patients, while the remaining 32 patients underwent general anesthesia via mask; and succinylcholine was administered prior to resection. Of the 57 patients received epidural anesthesia, 18 were diagnosed as inferolateral bladder tumors during endoscopy and had to undergo general anesthesia. Obturator nerve block was attempted preoperatively in 39 patients. However, a nerve identification failure, hematoma and 4 obturator nerve reflex events, despite the block, were ...
Theoretical and experimental results of investigating a cylindrical heat receiver with secondary reflectors are presented. One important element of solar thermal power plants (STPP) is the heat receiver. Several forms of heat receiver exist; the main form is the heat receiver of cavity form (including cylindrical, rectangular, and cubic heat receivers with a noncircular aperture). The linear dimension of such heat receivers is equal to, or larger than, the theoretical diameter of the concentrator focal spot.
The aim of this study was to evaluate the results of postoperative radiotherapy in a case of perihilar cholagiocarcinoma by analyzing overall survival rate, patterns of failure, prognostic factors for overall survival, and toxicity. Between January 1998 and March 2008, 38 patients with perihilar cholangiocarcinoma underwent a surgical resection and adjuvant radiotherapy. The median patient age was 59 years (range, 28 to 72 years), which included 23 men and 15 women. The extent of surgery was complete resection in 9 patients, microscopically positive margins in 25 patients, and a subtotal resection in 4 patients. The tumor bed and regional lymphatics initially received 45 Gy or 50 Gy, but was subsequently boosted to a total dose of 59.4 Gy or 60 Gy in incompletely resected patients. The median radiotherapy dose was 59.4 Gy. Concurrent chemotherapy was administered in 30 patients. The median follow-up period was 14 months (range, 6 to 45 months). ...
The purpose of this study was to examine the day-to-day reproducibility and single measurement reliability of peak force, time to half peak force and rate of force development indices of knee extension neuromuscular performance in patients with end-stage renal failure. Eleven self-selected patients (6 men, 5 women) receiving maintenance dialysis (dialysis history 67 +/- 42.8 month) completed 3 inter-day assessment sessions. Each comprised a standardized warm-up and 3 intermittent static maximal voluntary actions of the knee extensors of the preferred limb (45 degrees knee flexion angle [0 degrees = full knee extension]) using a specially-constructed dynamometer. Repeated measures ANOVA of coefficient of variation scores revealed significant differences between indices in their reproducibility across day-to-day trials. Post-hoc comparisons of group mean scores suggested that peak force (6.6 +/- 3.0%) offers significantly greater measurement ...
Purpose: The results of therapy in 288 men with pathologic Stage C prostate cancer who underwent radical retropubic prostatectomy (RRP) were analyzed to determine the effects of adjuvant therapy. Methods and Materials: Twenty-seven of the 288 patients received preoperative neoadjuvant hormonal therapy (leuprolide acetate). Postoperatively, 60 patients received adjuvant radiotherapy (RT) to the prostate bed. Follow-up ranged from 3 to 83 months (median = 32 months). Freedom from failure (FFF) was defined as maintaining a serum PSA level of #<=# 0.3 ng/ml. Results: The FFF was 61% at 3 years and 45% at 5 years for the entire group. The FFF following RRP plus RT was 75% at 3 years and 57% at 5 years as compared to 56% at 3 years and 40% at 5 years for RRP without RT (p = 0.049). The FFF following RRP plus neoadjuvant hormonal therapy was 58% at 3 years and 40% at 5 years as compared to 60% at 3 years and 45% at 5 years ...
During the past year, an experiment has been underway to test use of reliable multicast capabilities for transmission of continuous data in the Global Communication Infrastructure. For the experiment a version of the CD-1 protocol was multicast enabled. The experiment has demonstrated the feasibility of transmitting data in a multicast mode over the GCI. In the case of the Comprehensive Nuclear Test-Ban Treaty the sender could be the station and the receivers the International Data Center (IDC) and one or more National Data Centers (NDC). The potential advantages of multicasting include (a) the timely receipt of the data by the IDC and the host NDC and (b) the simultaneous availability of the raw station data at, at least, two locations. The latter, by introducing redundant data paths, decreases the probability of loss of station data due to a potential failure of a single data receiver. This experiment is only one element ...
Data communication in a computer network environment is facing serious security threats from numerous sources such as viruses, worms, Zombies etc. These threats can be broadly characterized as internal or external security threats. Internal threats are mainly attributed to sneaker-nets, utility modems and unauthorized users, which can be minimized by skillful network administration, password management and optimum usage policy definition. The external threats need more serious attention as these attacks are mostly coming from public networks such as Internet. Frequency and complexity of such attacks is much higher as compared to internal attacks. This paper presents a host based network layer screening of external and internal IP packets for logging, analyzing and real-time detection of possible IP spoofing and Denial of Service attacks. This work can also be used in tuning security rules definition for gateway firewalls. Software has been developed which intercepts IP traffic and ...
Objective To determine whether a centralised telephone intervention reduces the incidence of death or admission for worsening heart failure in outpatients with chronic heart failure.Design...Full Text Available
Heart failure affects nearly 6 million Americans, with a half-million new cases emerging each year. Whereas up to 50% of heart failure patients die of arrhythmia, the diverse mechanisms underlying...Full Text Available
Failure of a dam is something we hope never happens. But if a failure occurs, it`s important to study the circumstances in order to expand our knowledge base, and then apply what we learn to other structures.
Heart failure has been singled out as an emerging epidemic, which could be the result of increased incidence and/or increased survival leading to increased prevalence. Knowledge of the responsibility...Full Text Available
BackgroundProvision of consumer information and patient education are considered an essential part of chronic disease management programmes developed for patients with heart failure....Full Text Available
Ultimate compressive strength and failure modes were studied using 24- ... to 81 % of the average ultimate compressive strength (UCS). Figure 1 (a) is the failure ...
Congestive heart failure (CHF) is a leading cause of morbidity and mortality. CHF is marked by atrial and ventricular enlargement and reduced cardiac contractility, as well as an association...Full Text Available
Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available
Apparatus for minimizing thermal loss in a windowless, open cavity solar receiver due to airflow at the receiver aperture includes means for deflecting wind away from the cavity opening such that flow stream reattachment occurs away from the receiver aperture to provide a dead air zone at the cavity opening. This prevents turbulent-mixing airflow exchange between ambient air and heated air within the solar receiver. The wind deflector apparatus includes either a passive annular deflection foil at the receiver aperture, or an active device for producing an outwardly projected air jet at the receiver aperture.
Power system components, especially components failure, can significantly affect the reliability of a power system. Data about failure rate in electrical products were obtained from products life testing and analyzed in order to predict reliability. The distribution curve fitting method was used to estimate failure probability. Ten relays of different life times have been used to illustrate the validity of this analytical technique. 3 refs., 3 tabs.
A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).
This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.
An advanced ceramic dome cavity receiver is discussed which heats pressurized gas to temperatures above 1800/sup 0/F (1000/sup 0/C) for use in solar Brayton power systems of the dispersed receiver/dish or central receiver type. Optical, heat transfer, structural, and ceramic material design aspects of the receiver are reported and the development and experimental demonstration of a high-temperature seal between the pressurized gas and the high-temperature silicon carbide dome material is described.
Extensive investigations and detailed analysis of the failure reason of 9DVN002ZV fan in Daya Bay Nuclear Power Station showed that the fan destroy was caused by the failure of non-drive end bear. The direct cause of this bearing' failure was its improper assembly caused by improper maintenance procedure, and the root cause was too small internal radial clearance after mounting. The factor affecting bearing internal radial clearance, the relationship between clearance and operating life time and fan failure process were discussed. (authors)
The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)
Background and objectives: Patients receiving dialysis have a high burden of cardiovascular disease. Some receive coronary artery revascularization but the optimal method is controversial.Design,...Full Text Available
2 ...Amount received and number years supported Project Duration: 2 years Funding received from APN in Year1: US$...00 Funding received from APN in Year 2: US$40,000.00
A model for energy transport in a solid particle cavity receiver is developed and applied to the design and analysis of a receiver for the Central Receiver Test Facility (CRTF), Albuquerque, New Mexico. The model gives thermal performance results - including particle temperatures, cavity efficiencies, and wall temperatures - which directly affect the economic and technical feasibility of a solid particle receiver. In addition, design criteria relevant to the configuration of a solid particle cavity receiver are developed. Results for CRTF indicate that at design conditions particle temperatures will exceed 1200/sup 0/K with cavity efficiencies on the order of 75%.
The aim of this retrospective study was to determine the safety and efficacy of chemoembolization (TACE) as palliative treatment for patients with unresectable intrahepatic cholangiocarcinoma (CCA) and to compare the results with those in the literature. Fifteen patients with histology-proven CCA (5 men, 10 women) had received palliative treatment with TACE over a 6-year period. The treatment protocol comprised repeated TACE at a minimum of 8-week intervals. TACE was performed with a mixture of 10 ml Lipiodol and 10 mg mitomycin C injected into the tumor-supplying vessels. Follow-up investigations after 8-10 weeks comprised contrast-enhanced multislice spiral CT and laboratory control. Statistical evaluation included survival analysis using the Kaplan-Meier method. During the investigation period 58 TACEs (3.9 #+-# 3.8; 1-15) were performed in 15 patients. Mean tumor size was 10.8 #+-# 4.6 cm (range, 2.0-18.0 cm). Unifocal tumor disease was diagnosed in eight ...
The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after previous PTA. Stent ...
The role of radiation therapy in local tumor control and decreased incidence of pulmonary metastasis is reported in 271 patients who were entered into the Intergroup Ewing's Sarcoma Study with more than one year follow-up and on whom all radiotherapy records were reviewed. The majority of the patients were irradiated to the primary tumor with doses of 4500 to 6500 rad in five to six weeks in combination with systemic administration of three drugs (vincristine, actinomycin-D and cyclophosphamide) or four drugs (vincristine, actinomycin-D, cyclophosphamide and adriamycin). One of the groups of patients was treated with three drugs and bilateral pulmonary irradiation (1500 rad, uncorrected dose, in two weeks). Preliminary analysis shows an overall local primary tumor control of 89%. Patients with lesions in the pelvis had a local failure rate of 17% (9 of 52) and in the humerus 23% (7 of 31). Factors affecting local recurrences are analyzed in detail. Distant ...
This paper is a progress report on the role of radiation therapy (RT) in local tumor control and the decreased incidence of pulmonary metastasis in 251 patients entered in the Intergroup Ewing's Sarcoma Study. All were followed for more that 1 year, and their RT records were reviewed. Doses to the primary tumor in the range of 4,500--6,500 rad were administered over approximately 5 to 6 weeks in combination with 4 drugs, i.e., vincristine (VCR), dactinomycin (DAC), cyclophosphamide (CY), and adriamycin, or only the first 3. One group of patients received the 3 drugs and bilateral pulmonary irradiation (approximately 1,500 rad in 2 wk). Preliminary analysis showed a local primary tumor control of approximately 90%. Patients with lesions in the pelvis and humerus had local failure rates of 13% (7 of 54) and 21.4% (6 of 28), respectively. The treatment groups differed significantly in the incidence of pulmonary metastasis. Patients treated with ...
Gastrointestinal lymphomas are almost exclusively of a non Hodgkin's type. The Western form is characterized by a higher incidence of stomach location (50 %), a MALT type (mucosa associated lymphoid tissue) (40 %), a B-cell type (90 %), and a high grade (55 %). Chronic infection with Helicobacter pylori is an important risk factor. Mediterranean lymphomas form a particular clinical and pathological entity with diffuse involvement of the small bowel and are frequently being associated with a chronic malabsorption disorder. Eradication of Helicobacter pylori in early lymphomas, and the use of tetracyclines in early Mediterranean lymphomas, have been shown to induce durable remissions. For more advanced gastric lymphomas, treatment usually consists of anthracycline-based chemotherapy followed by involved field radiotherapy. Surgery is usually reserved for complications such as perforation or bleeding, or in some selected cases for salvage after failure of non-surgical ...
The HT-28 and 29 irradiation capsules are part of a cooperative agreement between GA and ORNL designed to evaluate irradiation performance of unbonded BISO and TRISO coated ThO_2 fertile fuel particles. The capsules will contain a total of 44 different positions uniformly divided between each capsule. The positions in HT-29 are designated for operation at 900"0C over a fast fluence increment between 5.4 to 10.7 x 10"2"1 n/cm"2 (E > 0.18 MeV)/sub HFIR/. Positions in HT-28 are divided into two sections: 11 positions at 1250"0C to receive a fast fluence exposure between 7.8 and 8.6 x 10"2"1 n/cm"2 (E > 0.18 MeV)/sub HFIR/ and 11 positions at 900"0C designed for a 4.3 to 6.9 x 10"2"1 n/cm"2 (E > 0.18 MeV)/sub HFIR/ fast fluence exposure. Both capsuls are to serve as an evaluation test to characterize the performance of BISO OPyC coatings deposited from mixed-gas (acetylene-propylene). The OPyC variables tested will be density, coating rate, and thickness. A ...
Purpose: To identify results and prognostic factors on long-term survival and local control following treatment of localized Ewing's sarcoma. Patients and Methods: Between 1979 and 2004, a total of 60 children and young adults with Ewing's sarcoma were treated. Patients with distant metastases at presentation (n = 6) and recurrent cases (n = 2) were excluded from this analysis. Patients were exclusively treated within ongoing national and international protocols CESS-81, CESS-86, EICESS-92, EURO-EWING-99. All patients received local irradiation with a total dose of 45-60 Gy; in addition, 41 (79%) of the patients had local surgical procedures, 27 (52%) of them with clear margins. Results: Overall survival rates at 5 and 10 years were 56% and 45%, respectively. Patients #<=# 14 years at diagnosis had overall survival rates of 66% and 61% at 5 and 10 years compared to older patients with corresponding survival rates of 47% and 31%, respectively (p = 0.05). Patients ...
The ability to mechanically reinforce an osteoporotic vertebral body could impede spinal compression fracture and the associated pain and complications. Previous studies have shown that reinforcement of fractured vertebrae with conventional acrylic cement can relieve symptoms and avoid further collapse. In this study, we explored the use of a carbonated apatite cement combined with a minimally invasive injection technique to improve the compressive mechanical properties of cadaveric vertebral bodies. After establishing the biomechanical characteristics of cement formulations intended to have appropriate viscosities, we evaluated the infiltration of the cements into thoracic vertebral bodies using a combined suction-injection technique. The energy-absorption capabilities of the reinforced vertebral bodies were then measured during axial compressive tests and compared with those of nonreinforced vertebrae. The ultimate compressive strength of the cement formulations averaged from 11.6 to ...
A 450 MeV Synchrotron Radiation Source, Indus-1 is being constructed at Centre for Advanced Technology at Indore in central India. This paper narrates our experience in construction and alignment of synchrotron machines which was first of its kind for most of us. Careful design, planning and execution of the work yielded modest results so that alignment accuracies between 0.1 to 0.3 mm could be achieved (in booster synchrotron) and, which have proved to be adequate up till now. The building of the SRS complex was constructed such that machine rings have their foundations isolated from rest of the building. A number of 100 x 150 mm size steel plates were embedded in the concrete of floor and walls to serve as base for reference surveying marks which were established later. The pre-injector and booster ring are enclosed in a radiation shielding zone with separate ventilation system. Dipoles, quadrupoles and a few sextupoles were fiducialised during their field mappings; on a CNC ...
May 16, 1995 ... She received an honorary doctorate of science from Northern Arizona University in 1990. With her husband, she received the Rittenhouse Medal ...
S>Hydrogen-induced delayed failure in an alpha-beta titanium alloy (4Al-- 4Mn) was sensitive to microstructure. A quenched structure was less susceptible to delayed failure than aged or annealed structures. The tendency for delayed failure was magnified in all structures by an increase in hydrogen content or an increase in strength level. Hydrogen-induced delayed failure occurred by a process of crack initiation and controlled crack growth. Delayed failures resulting from creep were also encountered. Plastic strain resulting from creep tended to retard crack initiation. Changes occurring in material under static load prior to formation of cracks were reversible, as long as no appreciable plastic strain occurred, indicating stress-induced diffusion of hydrogen. Hydrogen-induced delayed failure disappeared at both high and low ...
Abstract Background: Premature ovarian failure is diagnosed with a picture of amenorrhea, elevated follicle-stimulating hormone (FSH), and age under 40 years. Twenty percent (20%) of patients with premature ovarian failure have a concomitant autoimmune disease. Cases of premature ovarian failure associated with Sj?gren syndrome have been reported in the literature. Patient and method: We report a case of a 42-year-old white woman with Sj?gren syndrome and premature ovarian failure who underwent a reversal of her premature ovarian failure and restoration of normal menses using an elimination diet protocol. The patient was diagnosed with her rheumatological condition in 2005 and started on disease-modifying antirheumatoid drugs, which were taken intermittently due to a concern over medicatio...
Breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the utility`s breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting a circuit breaker from the failure described above, plus other failures that go unprotected with conventional schemes, this providing total ...
Thermal absorption with its combined thermal and mechanical loads in a solar receiver does depend significantly on the distribution of incident solar radiation. For a cavity receiver with paraboloid collectar a method is derived which enables the calculation of solar radiation distribution on the areas inside the receiver. The theoretical bases are presented first, and a subsequent example shows the influence of the most important geometric parameters on the distribution of solar radiation.
A preliminary study of two different kinds of solar receivers (a rotating cavity receiver and a volumetric receiver) suitable to operate in the 1 kW solar facility at the University of Rome is presented. Possible applications of solar energy in the aluminum extraction from leucite and chemical storage by the CuO/Cu[sub 2]O cycle are presented and discussed. (author).
The development and experimental demonstration of a high-temperature seal for the SHARE ceramic dome cavity receiver is reported. The mechanical contact seal which was tested on one-foot-diameter silicon-carbide ceramic-dome hardware at pressure differentials to four atmospheres and dome temperatures to 2200/sup 0/F (1200/sup 0/C) showed negligible leakage at expected receiver operating conditions. Potential solar receiver applications for the technology are illustrated.
Chronic heart failure (HF) is a cardiovascular disease of cardinal importance because of several factors: a) an increasing occurrence due to the aging of the population, primary and secondary prevention...Full Text Available
We describe a 59-year-old patient who developed acute renal failure because of rhabdomyolysis after extensive red fire ant bites. This case illustrates a serious systemic reaction that may occur from...Full Text Available
Refractory ascites can occur in patients with various conditions. Although several procedures based on the reinfusion of ascitic fluid have been reported after the failure of bed rest, salt and water...Full Text Available
Forty-six patients with end-stage renal failure were subjected to iliac crest biopsy before the initiation of a dialysis programme and regardless of the presence of skeletal symptoms....Full Text Available
BackgroundThe rhizomes of Cynodon dactylon are used for the treatment of heart failure in folk medicine. In the present study, we investigated the effects of hydroalcoholic...Full Text Available
Angiotensin II has adverse actions in heart failure including vasoconstriction, aldosterone secretion, and activation of the sympathetic nervous system. Valsartan, a potent specific angiotensin II type 1 receptor blocker, may produce beneficial effects in heart failure. The purpose of this study was to evaluate the steady-state pharmacokinetics of valsartan 40, 80, and 160 mg each given every 12 h for 7 days in heart failure patients. Eighteen patients with chronic stable heart failure and left ventricular ejection fractions power model, showed that doubling the dose increased the AUC and Cmax 1.8 times. The pharmacokinetics of valsartan are predictable in heart failure patients within the dose range of 40-160 mg BID. Age did not appear to have influenced the valsartan clearance in heart failure patients. The pharmacokinetic values were higher in heart ...
A mechanistic understanding of fracture in human bone is critical to predicting fracture risk associated with age and disease. Despite extensive work, a mechanistic framework for describing how the underlying microstructure affects the failure mode in bone is lacking.
BackgroundAlthough dilated cardiomyopathy (DCM) is a leading cause of heart failure (HF), the mechanism underlying DCM is not well understood. Previously, it has been demonstrated...Full Text Available
Background:The cardiac sodium–calcium exchanger (NCX1) is a key sarcolemmal protein for the maintenance of calcium homeostasis in the heart. Since heart failure...Full Text Available
Premature menopause, ovarian failure younger than 40 years of age, is relatively rare but may preclude childbearing for some women who delay attempts at fertility. We present five kindreds in which...Full Text Available
AimsTo determine the effect of exercise training on clinical events and health-related quality of life (HRQoL) of patients with systolic heart failure.Methods...Full Text Available
There is limited information about the true incidence of acute renal failure (ARF). Most studies could not quantify disease frequency in the general population as they are hospital-based and...Full Text Available
The design of a global steady-state thermal model of a 100kWt molten salt cavity receiver was developed as part of the key project of the Ministry of Science and Technology of People's Republic of China (MOST). In the design process, the following factors were analyzed: receiver area, heat loss (convective, emissive, reflective and conductive), number of tubes in the receiver panel, tube diameter and receiver surface temperature. The model was also used to calculate the receiver performance of the Sandia National Laboratories' molten salt electric experiment (MSEE). In addition, the thermal performance of the designed molten salt cavity receiver is presented for a fixed outlet flow rate and a fixed output temperature.
A thermal analysis of the Omnium-G receiver is presented and the technique is shown to be generally applicable to solar thermal receivers utilizing a directly heated thermal mass. The thermal loss coefficient, including reradiation losses, is calculated and shown to agree quite well with the experimentally measured thermal loss coefficient. The rate of heat transfer to the working fluid is also analyzed and the analysis is used to show that the Omnium-G receiver is well matched to the water/steam working fluid because the steam outlet temperature is almost the same as the receiver temperature. A general procedure for calculating receiver performance is presented. With this procedure, the energy delivery to any working fluid, the delivered temperature of the working fluid, and the pressure drop through the receiver can be determined. An example of the calculation ...
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of ...
The reliability of an electrical power system is influenced by the operation of circuit-breaker (CB). A good indicator of circuit-breaker condition is its switching time. Based on it some of the critical circuit-breaker irregularities can be detected and removed before they develop to a failure. In this paper, the evaluation of time measurements (timings) in case of different failures will be carried out for two circuit-breaker solutions, i.e. with spring and hydraulic drive. Moreover, the relationships between switching time and failure type/location will be derived. Thereby, the influence of failure trend will also be taken into account. (author)
Presented are the results of the investigation of the kinetics and micromechanism of the failure in impact bending of oriented-crystallized specimens having the eutectic composition Ni_3Al-Ni_3Nb and of the bimetal composed of 45 steel + M3 copper. The failure kinetics was studied by high-speed filming, whereas the fractures were studied by electron fractography. The particularities of the failure of the laminar-type composite materials were found. Analyzed was the effect of the kinetic factors and the mechanism of failure upon its energy consumption.
... with the additional US funds supporting Islamic ... the FATA and NWFP, keeping Pakistan's government and ... Without these madrassas, the TTP is left ...
Aluminum electrolytic capacitors, with 1043 failures, are a good example. Also, categorization by size and voltage reveals such frequencies of occurrence as ...
... which extend beyond the upper airway. These include attention deficit hyperactivity disorder, learning disorders, failure to thrive, and enuresis. Tonsillectomies ...
Considerable potential exists for increasing the annual efficiency of line-focus collectors by reducing receiver heat losses. Five alternate receiver designs are compared with a standard design. The comparison is based on annual collector-field efficiency using optimized receiver designs. Of the receivers studied, the all-glass design and the cavity design provide the greatest increases in efficiency. Average fluid temperatures range from 200/sup 0/ to 450/sup 0/C. As a guide for further study, areas of uncertainty and potential problems are identified.
An improved hybrid solar/combustion powered receiver of the type having an insulated housing with a front end and a rear end, a heat exchanger positioned adjacent the rear housing end for extracting heat energy out of the receiver, the insulated housing surrounding the heat exchanger and forming a receiver cavity, the housing also including an aperature having an aperture axis, the aperture located in the front housing end for admitting solar radiation to the cavity to impinge upon the heat exchanger, and a plurality of gas burners to provide combustion gases within the receiver.
Numerical analysis of solar dish modified cavity receiver with Cone, CPC and Trumpet reflectors is presented. Three-dimensional modeling is carried out to estimate the convective and radiative heat loss from the receiver for different angles of inclination and operating temperatures. Incorporating reflectors in the modified cavity receiver for second stage concentration, the natural convection heat losses are reduced by 29.23, 19.81 and 19.16%, respectively. The receiver with the trumpet reflector has shown better performance as compared to other configurations. (orig.)
Stability concerns of the Par Pond Dam, an embankment structure in the Savannah River Site complex, resulted in a comprehensive evaluation of the state of its integrity. Specifically, excessive seepage through the embankment, slope failure due to an earthquake event as well as liquefaction potential of the embankment and the foundation are addressed and the potential of failure is evaluated. Lastly, remedial benefits of the addition of a berm structure are also assessed.
Heart failure goes beyond mechanical dysfunction and involves an interplay of multiple pathophysiologic mechanisms, including inflammation, tissue remodeling, neurohormonal and endocrine signaling, and interactions with the renal and nervous systems. This article highlights some novel biomarkers that may aid in diagnosis, treatment, and prognosis of acute heart failure, specifically focusing on ST2, endoglin, galectin-3, cystatin C, neutrophil gelatinase?associated lipocalin, midregional pro-adrenomedullin, chromogranin A, adiponectin, resistin, and leptin and their emerging clinical roles.
AimsThe prevalence and importance of liver function test (LFT) abnormalities in a large contemporary cohort of heart failure patients have not been systematically evaluated.Full Text Available
A case study is presented about the failure of a stainless steel blade reinforcing band in a steam turbine. The inspection results and analysis of samples of material are discussed. Being pitting corrosion and cracks the main defects found, a study of chemical composition and heat treatment state of the steel is made and findings are related to type of failure. (orig.)
1 The decreased binding of drugs and dyes to plasma proteins from male and female rats with acute renal failure has been investigated using equilibrium dialysis at 37 degrees C. 2 Acute renal failure...Full Text Available
Most of previous study for creep rupture of RPV lower head under severe accident condition, have been focused on global failure of RPV lower head. In contract, the local failure of the RPV nozzle region has not been studied in detail. The existence and features of nozzle failure in LAVA-ICI specimen of KAERI and LHF-4 specimen of Sandia National Lab., are observed. It is confirmed that the nozzle failure of LHF-4 specimen is due to the hoop stress in the RPV. The tensile tests in various temperatures and the creep rupture tests in various temperatures and stresses, are accomplished. The finite element analysis for LAVA-ICI experiment was confirmed, and the stress and deformation analysis results are used in LAVA-ICI experiment. 17 refs., 34 figs., 3 tabs. (Author)
In the field of Living Probabilistic Safety Assessment (LPSA) the reliability data updating is an important factor. In risk analysis equipment failure data is needed to estimate the frequencies of events contributing to risk posed by a facility. Five years data of emergency diesel generator (EDG) of Daya Bay Nuclear Power Plant (NPP) has been studied in this paper. The data updating process has been done by using two methods, i.e., the classical method and Bayesian method. The aim of using these methods is to calculate the operational failure rate (@l) and demand failure probability (p). The results show that the operational failure rate is 1.7E-3 per hour and the demand failure probability is 2.4E-2 demand per day for Daya Bay NPP. By comparing the results obtain from classical and Bayesi...
Else of solar energy as substitute for conventional fuels at a competitive cost requires efficient conversion from solar radiation to usable forms of energy. In solar thermal or thermochemical applications, high efficiency usually re- quires high temperature and high concentration of incoming radiation. The main form of energy loss from high temperature solar central receivers is thermal emission ('re radiation'), at an effective temperature close to the maximum receiver temperature. This loss is reduced if the aperture is divided into segments, most of which are maintained at lower temperatures. A two-stage partitioned receiver demonstrating this concept is under construction at the Weizman Solar Tower. The high-temperature stage is the DIAPR (Directly Irradiated Annular Pressurized Receiver). The low-temperature stage is made of tubular cavity receivers of simpler design. ...
To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression. Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse the mean period of patency, the Kaplan-Meier method was used. Thirty of 31 attempted ...
Purpose: We present an update analysis of the multiinstitutional Ewing's sarcoma study CESS 86. Methods and Materials: From January 1986 through June 1991, 177 patients with localized Ewing's sarcoma of bone, aged 25 years or less, were recruited. Chemotherapy consisted of four 9-week courses of vincristine, actinomycin D, cyclophosphamide, and adriamycin (VACA) in low-risk tumors (extremity tumors =# 100 cm"3). Local therapy was an individual decision in each patient and was either radical surgery (amputation, wide resection) or resection plus postoperative irradiation with 45 Gy or definitive radiotherapy with 60 Gy (45 Gy plus boost). Irradiated patients were randomized concerning the type of fractionation in either conventional fractionation (once daily 1.8-2.0 Gy, break of chemotherapy) or hyperfractionated split-course irradiation simultaneously with the VACA/VAIA chemotherapy (twice daily 1.6 Gy, break of 12 days after 22.4 Gy and 44.8 Gy, total dose and treatment time as for ...
According to the California Earthquake Authority, only about 12% of current California residences are covered by any form of earthquake insurance, down from about 30% in 1996 following the 1994, M6.7 Northridge earthquake. Part of the reason for this decreasing rate of insurance uptake is the high deductible, either 10% or 15% of the value of the structure, and the relatively high cost of the premiums, as much as thousands of dollars per year. The earthquake insurance industry is composed of the CEA, a public-private partnership; modeling companies that produce damage and loss models similar to the FEMA HAZUS model; and financial companies such as the insurance, reinsurance, and investment banking companies in New York, London, the Cayman Islands, Zurich, Dubai, Singapore, and elsewhere. In setting earthquake insurance rates, financial companies rely on models like HAZUS, that calculate on risk and exposure. In California, the process begins with an official earthquake forecast by the ...
Microelectronic failure analysis (FA) has been an integral part of the development of state-of-the-art integrated circuits. FA of MicroElectroMechanical Systems (MEMS) is moving from its infancy stage to assume an important role in the successful design, fabrication, performance and reliability analysis for this new technology. In previous work, the authors focused on the application of several techniques developed for integrated circuit analysis to an earlier version of a surface micromachined microengine fabricated at Sandia. Recently, they have identified important new failure modes in binary counters that incorporate a newer design of the microengine, using a subset of integrated circuit failure analysis techniques including optical microscopy, focused ion beam (FIB) techniques, atomic force microscopy (AFM), and scanning electron microscopy (SEM). The primary failure mode they have identified is ...
Solar cavity receiver plays a dominant role in the light-heat conversion. Its performance can directly affect the efficiency of the whole power generation system. A combined calculation method for evaluating the thermal performance of the solar cavity receiver is raised in this paper. This method couples the Monte-Carlo method, the correlations of the flow boiling heat transfer, and the calculation of air flow field. And this method can ultimately figure out the surface heat flux inside the cavity, the wall temperature of the boiling tubes, and the heat loss of the solar receiver with an iterative solution. With this method, the thermal performance of a solar cavity receiver, a saturated steam receiver, is simulated under different wind environments. The highest wall temperature of the boi...
An energy transfer and conversion model for high-temperature solar cavity receivers has been developed using the transport behaviour of solar radiation as described by the spectral radiative exchange factors. A Monte-Carlo ray-tracing method coupled with optical properties was adopted, to predict radiation characteristics of the solar collector system by calculating radiative exchange factors. A cavity receiver with a plano-convexo quartz window was proposed, based upon the directional characteristics of the focal flux and the redistribution effect of the quartz window. Parametric studies on the windowed receiver provided a more uniform flux distribution, higher efficiency and lower loss than the windowless receivers. The predicted results serve as a design reference for the solar receiver...
The development of central receiver technology for the production of electricity is reasonably well established. One possible direction for future research and development efforts funded by the Department of Energy is high-temperature, high-performance systems. In this paper, the performance of central receiver systems is investigated for a range of heliostat sizes, field configurations, plant sizes, and receiver temperatures. The maximum plant efficiency achievable in a central receiver system that uses simple cavity geometry is shown for a range of receiver temperatures. The impact of changes in heliostat size, field packing density, and canting and focusing strategies on system efficiency are investigated over a range of plant sizes. The results of the study underscore the importance of accommodating high absorber plane fluxes in order to efficiently produce working temperatures ...
The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).
Results from a numerical model of axisymmetric solar cavity receivers are compared with experimental data for tests of a novel test bed receiver in the Saudi National Laboratories solar furnace. The computed energy transfer rates and temperatures are compared with the experimental data for different receiver geometries, aperture sizes, and operating conditions. In general, the agreement between the numerical model and the experimental data is better for the small-to-midsized apertures than for the large apertures. The analysis indicates that for the larger apertures, the convective heat losses are overpredicted. It also suggests that these losses could be better characterized. Sensitivity analyses show that both the total solar energy input rate and the convective heat-loss coefficient significantly affect the receiver thermal performance and that the distribution of the input solar flux significantly ...
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparabl...
This probabilistic analysis of WIPP TRUDOCK crane failure is based on two sources of failure data. The source for operator errors is the report by Swain and Guttman, NUREG/CR-1278-F, August 1983. The source for crane cable hook breaks was initially made by WIPP/WID-96- 2196, Rev. O by using relatively old (1970s) U.S. Navy data (NUREG-0612). However, a helpful analysis by R.K. Deremer of PLG guided the authors to values that were more realistic and more conservative, with the recommendation that the crane cable/hook failure rate should be 2.5 x 10-6 per demand. This value was adopted and used. Based on these choices a mean failure rate of 9.70 x 10-3(1/yr) was calculated. However, a mean rate by itself does not reveal the level of confidence to be associated with this number. Guidance to making confidence calculations came from the report by Swain and Guttman, who stated that ...
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
The United States and Russia have agreed to jointly develop a solar dynamic (SD) system for flight demonstration on the Russian Mir space station starting in late 1997. Two important components of this SD system are the solar concentrator and heat receiver provided by Russia and the US, respectively. This paper describes optical analysis of the concentrator and solar flux predictions on target receiver surfaces. The optical analysis is performed using the code CIRCE2. These analyses account for finite sun size with limb darkening, concentrator surface slope and position errors, concentrator petal thermal deformation, gaps between petals, and the shading effect of the receiver support struts. The receiver spatial flux distributions are then combined with concentrator shadowing predictions. Geometric shadowing patterns are traced from the concentrator to the target receiver surfaces. ...
A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of inclinations (60 {<=} {beta} {<=} 90 ) of the ...
This report is a compilation of worksheets from the waste management units of Savannah River Plant. Information is presented on the following: Solid Waste Management Units having received hazardous waste or hazardous constituents with a known release to the environment; Solid Waste Management Units having received hazardous waste or hazardous constituents with no known release to the environment; Solid Waste Management Units having received no hazardous waste or hazardous constituents; Waste Management Units having received source; and special nuclear, or byproduct material only.
Solar heating of gas turbine plants steps back more and more into the focus of current research. The mainly instationary operation of solar turbine power plants can only be predicted with sufficient accuracy if the transient behaviour of the receiver for the solar radiation is known. Therefore the transient behaviour of cavity receivers of different design is investigated. The mathematical model used for the simulation of the heat transfer and energy storage processes is illustrated. Computed results for receivers with various inner lining are compared and evaluated concerning their use in practice.
Solar heating of gas turbine plants is moving back to the focus of current research. The mainly unsteady operation of solar turbine power plants can only be predicted with sufficient accuracy if the transient behavior of the solar radiation receiver is known. Therefore the transient behavior of cavity receivers of different designs is investigated. The mathematical model used to simulate heat transfer and energy storage is illustrated. Computed results for two receivers with different inner lining are compared and evaluated concerning their use in practice.
... mounted new operations against the TTP stronghold in ... was the fourth tranche of Pakistan's IMF-backed ... and brought the total funds received by ...
... losing unit should document reasons for rehabilitation in a counseling with a view ... of the reprimand and have received at least one OER or NCOER. ...
An electric power generating apparatus is described, including: a solar collector; a primary thermal loop including primary thermal fluid; a cavity receiver to receive reflected solar energy from the solar reflector, convert the solar energy into thermal energy, and transmit the thermal energy to the primary thermal fluid by heating the primary thermal fluid not to exceed a given temperature, the given temperature being substantially equal to 700 F; a Stirling engine receiving the primary thermal fluid heated by the cavity receiver, including means to generate mechanical power and means to generate electrical power from the means to generate mechanical power.
The theory for the general case of solar cells operating inside integrating cavity receivers is established. This is applied to the particular case of different configurations of silicon and GaAs cells. The results of the analysis show that a composite system of silicon and GaAs cells manufactured using relatively simple technology could reach an efficiency of 34%. The optimal configuration is that in which the GaAs cells are placed in the directly illuminated area of the receiver and the silicon cells are placed in the indirectly illuminated area of the receiver. (orig.).
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
The receiver whose convective heat loss test results are presented was designed to absorb 5 MW of solar energy, using a molten salt working fluid. During the tests, this receiver was brought to a temperature of about 343 C by a small group of heliostats. Total receiver heat loss due to emitted radiation, conduction and convection was first determined, and the convection loss was established by calculating the radiation and conduction losses analytically and subtracting their sum from the total. Losses due to convection are found to be 1.43 percent of the total heat input.
The conception of a solar receiver intended to equip a tower power-station has to combine multiple requirements: very highly concentrated solar flux, unsteady in time and space; necessity to obtain a high efficiency; respect of the physical limits of the materials and of the fluid. The description of Themis solar receiver and of its operation is preceded by considerations which have led to the choice of the cavity, of the fluid and of its circulation.
A solar unit is described which contains a cavity radiation receiver, parabolic-cylindrical concentrator, and reflector arranged between the radiation receiver and the concentrator symmetrically in relation to the optical plane of the latter. In order to expand the range of use, it contains a pair of flat mirrors with 2 working surfaces installed at an angle and symmetrically to the optical plane of the parabolic cylindrical concentrator between them and the reflector, while the latter is made in the form of 2 flat mirrors installed at an angle on the cavity radiation receiver.
Two patients receiving maintenance dialysis therapy developed osteonecrosis, the first in the humeral head and the second in the talus. Both patients lacked known risk factors for developing osteonecrosis. A possible pathogenic role of secondary hyperparathyroidism in this disorder is suggested. Rheumatologists evaluating patients receiving maintenance dialysis with rheumatic manifestations should be aware of this potential complication. PMID:2185360
This report uses experimental data to compare the performance of two sodium cooled solar central receivers operated at the International Energy Agency Small Solar Power Systems project near Almeria, Spain. Performance includes point-in-time steady state efficiency, average efficiency, start-up time, and operation time. Point-in-time steady state efficiency calculations were based on the statistical method of least squares using receiver incident and absorbed powers. One receiver, a cavity type, showed a peak steady state receiver efficiency of 87% +- 5% and an average efficiency of about 67%. The other receiver, an external ''billboard'' type, had a peak steady state receiver efficiency of 96% +- 4% and an average efficiency of about 79%. The original design peak steady state efficiency predictions for both ...
The concept of a multi-cavity volumetric solar receiver is very attractive for the profitability of certain of its characteristics such as high efficiency and economy. The absorber is based on a pack of small ceramic cavities which intercept and absorb the inherent high solar flux reflected from an array of mirrors. Atmospheric air acts as a coolant medium when it is drawn through the pack. A model for an overall heat transfer performance of the receiver is given and numerically solved.
In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)
The mainly nonstationary operation of a solar-heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
The mainly instationary operation of a solar heated receiver can be simulated with sufficient accuracy only if data about the dynamic behavior are available. For this reason, the dynamic behavior of a solar cavity receiver with parabolic dish collector is investigated. The development of a mathematical simulation considering heat transfer and storage processes is presented and the procedure for a numerical solution is illustrated. The performance of the calculation method is finally demonstrated by simulating the passage of a cloud.
Polyethylene gas piping is expected to be in service for times on the order of 50 years depending on service conditions. Therefore research research on piping materials and pipes has two principal objectives: (a) developing methods for predicting when a pipe will fail and (b) improving the material for piping. The prediction of long time failure hinges on the development of short time test methods which relate to long time failure. The improvement in the behavior of current materials also hinges on the use of test methods of short duration relative to the anticipated life time of the pipe in service. One of the primary criterion for an acceptable test method is that it produces the same type of failure as is observed after long time failure in service. It has been found that P.E. pipe material fails in a brittle mode after long periods of time. The failure mode is called brittle ...
The TS-1 and TS-2 TREAT transient experiments subjected a low burnup (2 MWd/kg) and a medium burnup (58 MWd/kg), respectively, FFTF irradiated fuel pin to unprotected 5 cents/s overpower transient conditions. The fuel pin failure response was similar in the two tests, which demonstrated a large margin to failure (P/P_0 > 3) and a favorable upper level failure location. Thus, for these transient conditions, burnup effects on transient performance appeared to be minimal in the range tested. Pin disruption in the medium burnup TS-2 test was more severe due to the higher fission gas pressurization, but failure occurred at only a 5% lower power level than for the low burnup TS-1 fuel pin. Both tests exhibited axial extrusion of molten fuel to the region above the fuel column several seconds before pin failure, demonstrating a potentially beneficial inherent safety mechanism to delay ...
Airborne pollutants can cause failures in switching and computing equipment. This paper focuses on a subset of such pollutants - airborne fine particles (<2.5 [mu]m diameter). It begins by examining the extent to which different improvements in heating, ventilating and air conditioning (HVAC) systems reduce indoor concentrations of fine particles. For each modification, the consequent reduction in soiling rate is derived. The concomitant increase in operating costs is also calculated. These costs are then compared with the costs of failures in telephone switching offices, leading to estimates of failure rate reductions that would make improvements cost-effective. Finally, the reduction in failures required to offset the costs of the improvements are compared with documented differences in failure rates between unimproved and improved environments. This study suggests that, in ...
This paper presents a method for the optimal design of high voltage transmission lines taking into consideration shielding and backflashover failure rates. The minimization of suitably defined performance indices, which relate the failures caused by lightning in a transmission line to both line insulation level and tower footing resistance, is aimed. Optimum values for both line insulation level and tower footing resistance are calculated. The method is applied on several operating Hellenic transmission lines of 150 and 400kV, respectively, carefully selected among others, due to their high failure rates during lightning thunderstorms. Special attention has been paid on open loop lines, where a possible failure could bring the system out of service causing significant problems. The obtained design parameters, which reduce the failure rates caused by lightning, are compared with the ...
This study describes the formulations to optimize the time interval of inspections and/or replacements of equipment/parts taking into account the probability density functions (PDF) for failure rates and parameters of failure distribution functions (FDF) and evaluates the optimized results of these time intervals using our formulations by comparing with those using only representative values of failure rates and the parameters of FDF instead of using these PDFs. The PDFs are obtained with Bayesian method and the representative values are obtained with likelihood estimation method. However, any significant difference is not observed between both optimized results within our preliminary calculations. (author)
A wood/polymer composite was produced by impregnating Ramin wood with methyl methacrylate monomer and subsequently polymerizing it by gamma irradiation. To assess the improvement in compression strength of the wood caused by the polymer impregnation, a microbuckling compression failure mechanism was used to model the compression failure of the composite. Such a mechanism was found to predict a linear relationship between the compression strength and the percentage polymer impregnation (by weight). Uniaxial compression test results at 45({plus minus}5)% and 90({plus minus}5)% relative humidity levels, after being statistically analysed, showed that such a linear relationship was valid for up to 100% polymer impregnation. (author).
A wood/polymer composite was produced by impregnating Ramin wood with methyl methacrylate monomer and subsequently polymerizing it by gamma irradiation. To assess the improvement in compression strength of the wood caused by the polymer impregnation, a microbuckling compression failure mechanism was used to model the compression failure of the composite. Such a mechanism was found to predict a linear relationship between the compression strength and the percentage polymer impregnation (by weight). Uniaxial compression test results at 45(#+-#5)% and 90(#+-#5)% relative humidity levels, after being statistically analysed, showed that such a linear relationship was valid for up to 100% polymer impregnation. (author).
Oak Ridge National Laboratory (ORNL) has for over ten years provided materials testing and failure analysis services to various coal conversion and utilization facilities in the United States. ORNL was involved in these types of activities at all four of the major coal liquefaction pilot plants. This paper presents a summary of activities at Wilsonville over the past two and one-half years. Some details of these activities are discussed below. Failure analysis of elastomers, stainless steels, and alloys is discussed. 6 refs., 9 figs., 13 tabs.
The wind industry has experienced premature turbine component failures during the past years. With the increase in turbine size, these failures, especially those found in the major drivetrain components, i.e. main shaft, gearbox, and generator, have become extremely costly. Given that the gearbox is the most costly component in the drivetrain to fix, the National Renewable Energy Laboratory (NREL) initiated the Gearbox Reliability Collaborative (GRC) to determine the causes for premature gearbox failures and subsequently, recommend improvements to gearbox design, manufacture, and operational practices. The GRC has two identical test gearboxes, which are planned for a dynamometer and a field test, respectively.
There has been a steady increase in the number of revision total knee arthroplasties being performed in the United States. Hinge knee prostheses are used predominantly in complex primary or revision arthroplasties, often as salvage procedures. Significant improvement of the articulation between the rotating hinge mechanism and tibial component has decreased the stresses that contributed to earlier failures in previous generation designs. Two cases of fracture of the tibial metal post in the rotating hinge of a revision total knee arthroplasty were evaluated and treated at our institution within a 1-month period. We present our experience with this construct failure and subsequent patient management.
A fuel plate examination was conducted in the hot cell and canal to determine the possible failure modes for three plates leaking fission products. The plates were irradiated in the Extended Life Aluminide Fuel (ELAF) program in support of university research reactor goals to increase the limits presently allowed. The examination indicated pitting corrosion to be the failure mode. Other failure modes such as: (a) nonbonded swelling, (b) excessive fuel swelling, and (c) overheating of the plates were not observed.
of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...
Several randomized studies have been completed in prostate cancer that show a benefit to immediate postoperative treatment in patients undergoing prostatectomy. In one of the studies, there was even...Full Text Available
Mangroves are disappearing rapidly worldwide despite their well documented biodiversity and the ecosystem services they provide. Failure to link ecological processes and their societal benefits has...Full Text Available
The location of defective LMFBR fuel pins by the determination of gas tag isotopic ratios is discussed. The application of this method to the FFTF Reactor briefly described.
The coolant activity analysis to obtain the information about the fuel failure has been studied long before. And several codes have been developed to estimate the number of fuel failures through evaluating volatile and inert fission products release in coolant from the defective fuel. These codes use a fission product diffusion model coupled with a mass balance in the gap and coolant. But each code has a different model to assess fuel failure. In order to develop the model to estimate the number of fuel failures we analysis well-known code's models such as CHIRON, CADE, IODYNE, and CAAP and compare accuracy through Korean PWR activity data
Corrosion failures in circuits of foreign NPPs are considered. According to American statistics there are more corrosion failures in two-circuit NPPs than in NPPs with one circuit. Steam generators mostly suffer from ''corrosion denting''. Lately pitting corrosion becomes a potentially serious problem. Steam generator vertical tubes are mainly subjected to this corrosion type. Attention is drawn to intercrystalline corrosion. The causes of corrosion are described. The problem of optimization of structural materials is discussed to reduce corrosion failures as well as other methods of decreasing corrosion failures. Organization of nondestructive testing, increased requirements to water and steam purity are of great importance.
A general purpose Emergency Generator Set (EGS) is considered for a methodological study and related reliability behavior is analyzed. In particular in a procedure of reliability and availability analysis of a EGS, dependent failure events need a complex mathematical model as state-space model to be a accurately evaluated. Furthermore these dependent failure events are one of the most important reliability characteristic of EGS. This paper suggests a procedure for reliability calculations in presence of dependent failure based on the evaluation of a equivalent failure rate that can be fitted to a network reduction method by simple mathematical calculations. The simplified models analyzed show a good accuracy for a wide range of variation of main reliability characteristics of EGS and utility. The advantages obtained are very useful on reliability evaluation because the possibility of use of network ...
... position must not be penalized in their NCO Evaluation Report (NCOER). ... failure to perform MOS-, SQI-, or ASI-related duties after counseling. ...
The most frequent ultimate cause of death is myocardial arrest. In many cases this is due to myocardial hypoxia, generally arising from failure of the coronary macro- and microcirculation to deliver...Full Text Available
Results are presented from a numerical model of the steady-state energy transfer in molten-salt-in-tube solar cavity receivers that includes convective energy transfer at a local (spatially resolved) level. Molten salt energy absorption and gray radiative transfer between all cavity surfaces are also included. This model is applied to the Molten Salt Subsystem Component Test Experiment (MSS/CTE) cavity receiver. Results for this receiver indicate the global (entire cavity) receiver thermal efficiency is invariant within a few percent to most parameters investigated, although front surface temperatures of the nonabsorbing walls vary considerably, and are particularly sensitive to the type of convective submodel used. Absorption efficiencies indicate the effects of the cavity enclosure environment. For all conditions investigated, tube inner wall temperatures remain under 855 K, ensuring that the salt ...
Properly quantified performance of a solar-thermal cavity receiver must not only account for the energy gains and losses as dictated by the First Law of thermodynamics, but it must also account for the quality of that energy. Energy quality can only be determined from the Second Law. In this paper, an equation developed for the Second-Law efficiency of a cavity receiver is presented as an evolution from the definition of available energy or ''availability'' (occasionally called exergy). The variables required are all either known or readily determined. The importance of considering the Second-Law is emphasized by a comparison of the First- and Second-Law efficiencies around an example of data collected from two receivers that were designed for different purposes, where the attempt was made to demonstrate that a Second-Law approach to quantifying the performance of a solarthermal cavity ...
Cavity solar receivers are generally believed to have higher thermal efficiencies than external receivers due to reduced losses. A simple analytical model was presented by the author which indicated that the ability to heat the air inside the cavity often controls the convective loss from cavity receivers. Thus, if the receiver contains a large amount of inactive hot wall area, it can experience a large convective loss. Excellent experimental data from a variety of cavity configurations and orientations have recently become available. These data provided a means of testing and refining the analytical model. In this manuscript, a brief description of the refined model is presented. Emphasis is placed on using available experimental evidence to substantiate the hypothesized mechanisms and assumptions. Detailed comparisons are given between analytical predictions and experimental results. Excellent ...
The present paper deals with the conversion of solar energy in a gas turbine plant with a parabolic dish collector. Particular consideration is devoted to the thermodynamic and mechanical design and partload behavior of the receiver. The incident sunlight is focussed by the parabolic dish and then beamed into the cavity receiver. Here the working medium of the gas turbine flows through tubes and is heated up to the receiver outlet temperature. The task of the receiver is to transfer the radiated energy as efficiently as possible to the working medium. Furthermore the required heating surface should be small as possible i.e. optimum use must be made of the tube material with respect to its state of stress. It is shown which geometric and thermodynamic plant parameters influence these two design criteria. An optimum receiver design is presented on the basis of the results thus ...
Failure of multiple components due to a common cause represents one of the most important issues in evaluation of system reliability or unavailability. The frequency of such events has relatively low expectancy, when compared to random failures, which affect individual components. However, in many cases the consequence is a direct loss of safety system or mitigative safety function. For this reason, the modeling of a common cause failure (CCF) and its presentation in fault tree structure is of the uttermost importance in probabilistic safety analyses (PSA). Amongst the different techniques available to reduce the impact of common cause failures, the most important operations related technique, is that of staggered testing. In the TAPP 3,4 Level-1 PSA it was found that the contribution of Common Cause Failures to the Core Damage Frequency (CDF) was significant. The Common Cause ...
The purpose of the Microelectronic Evaluation Laboratory at Sandia is to develop a program for evaluating CMOS LSI (complementary metal oxide silicon - large scale integrated) technology devices which are being used for the first time in a weapon system. These evaluations are based on accelerated aging studies and electrical tests to determine the reliability and life of the devices. In accelerated aging, specific, controlled stresses are applied to the device to accelerate time-to-failure. Data are used tin mathematical models to estimate life in acutal use. The stresses used for this technology are temperature and voltage. The devices are stored at temperatures with or without voltage applied (steady-state or cyclical) and periodically tested until at least 50% failures are encountered. Since most current technologies use epoxy-die-attachment, aging temperatures must be under 200/sup 0/C. This delays device failure, and a ...
Only a small number of radiation accidents in the United States have been severe enough to result in multi-organ failure (MOF). Medical details of selected medical misadministration and criticality cases are reviewed, with an emphasis on pathophysiology. The four criticality cases are particularly relevant for analysis of MOF, since medical treatment was supportive and did not appreciably alter the clinical evolution of radiation injury. PMID:15975871
This paper investigates the calculation of availability for parallel transmission lines (two or more) in the same tower or on the same right of way. As in many studies, the development of mathematical models is an important step. The models are justified using historical data and known characteristics of power system elements. A statistical method was used to generalize the failure rate and repair rate from real operating data. Application of the new model (which combines common-mode, simultaneous independent, and dependent outages) is discussed.
This report contains the results of a survey of reactor coolant pump shaft seal reliability. The survey sample is representatively large (approx. = 27% of total US commercial plant population) and includes the three industry seal suppliers (Bingham-Williamette, Byron Jackson, and Westinghouse). Operationally incurred/induced problems and seal redesign parameters are identified. Failure hypotheses in the form of fault trees have been developed to describe the failure mechanisms. Recommendations are made for seal reliability improvement.
The paper presents results of studies on the effect of heat treatment on strength and pattern of 40Kh steel impact failure. Loading levels corresponding to macroscopic spalling microdamage initiation in the material are determined for three initial states. Metallographic study on the spalling failure pattern for 40Kh steel in different initial states and data on microhardness measurement are presented.
Probabilistic assessment methods can be used to identify specific plant vulnerabilities. Application of such methods can also facilitate selection among system design alternatives available for safety enhancements. The quality of assessment results is however strongly dependent on realistic and accurate input data for modelling of system component behaviour and failure modes during conditions to be assessed. Use of conservative input data may not lead to results providing guidance on safety upgrades. Adequate input data for probabilistic assessments seems to be lacking for at least failure modes of some electrical components when exposed to a fire. This report presents an attempt to improve the situation with respect to such input data. In order to take advantage of information in existing documentation of fire incident occurrences some of the lessons learned from the fire at Browns Ferry Nuclear Power Plant on March 22, 1975 are discussed in ...
A historical overview of corrosion problems found in power plant condensers and mitigation procedures is presented. The paper is organized according to alloy type and failure mode. Alloys considered are copper-base alloys, stainless steels and titanium. Failure modes discussed include erosion-corrosion, sulfide attack, environmentally assisted cracking, galvanic corrosion, steam condensate corrosion, pitting corrosion, and dealloying. Mitigation procedures discussed include cathodic protection, ferrous ion injection, as well as tube cleaning and layup practices.
Power devices such as MOSFETSs and IGBTs, include parasitic structures that can give rise to destructive failures such as breakdown and latch-up. To determine a suitable strategy for device radiation hardening, simulation software like MEDICI-2D can be used to model the effects of technological modifications and device parameters that are difficult to measure experimentally. (authors).
On February 9, 1995 ComEd experienced a pipe type cable failure on 138kV line 13717. Line 1737 is a bulk power transmission cable circuit connecting The Fisk and Crawford generating stations located within city limits. The line is approximately 4.5 miles long and was originally installed in 1975. This line is forced cooled, has 2,500 KCMIL copper conductors with 505 mils of paper insulation in an 8 inch pritec coated steel pipe. The splices are constructed with Voltalit castings. The failure occurred approximately 3,500 feet from Crawford Station. It was easy to locate the failure since the cable joint casing was breached resulting in the loss of approximately 2,600--2,700 gallons of dielectric fluid. Upon field examination B Phase was determined to have failed. The failure occurred 12 inches inside the casing in an area where it was impossible to install a long connector or add an additional short ...
Reliability has an impact on wind energy project costs and benefits. Both life test data and field failure data can be used for reliability analysis. In wind energy industry, wind farm operators have greater interest in recording wind turbine operating data. However, field failure data may be tainted or incomplete, and therefore it needs a more general mathematical model and algorithms to solve the model. The aim of this paper is to provide a solution to this problem. A three-parameter Weibull failure rate function is discussed for wind turbines and the parameters are estimated by maximum likelihood and least squares. Two populations of German and Danish wind turbines are analyzed. The traditional Weibull failure rate function is also employed for comparison. Analysis shows that the three-parameter Weibull function can obtain more accuracy on reliability growth of wind turbines. This work will be ...
A 25m wind turbine blade was tested to failure when subjected to a flapwise load. With the test setup, it was possible to test the blade to failure at three diffe-rent locations. The objective of these tests is to learn about how a wind turbine blade fails when exposed to a large flapwise load and how failures propagate. The report shows also results from ultra sonic scan of the surface of the blade and it is seen to be very useful for the detection of defects, especially in the layer between the skin laminate and the load carrying main spar. Acoustic emission was successfully used as sensor for the detection of damages in the blade during the test. The report contains measurements of the total deflection of the blade, the local deflection of the skin and the load carrying main spar and also measurement of strain all as a function of the applied load and up to failure of the blade. The 'post ...
A modified boundary element approach was used to analyze the response of offshore piles subjected to external soil movements. The computer model employed to solve the pile-soil problem was able to model pile head and tip loading, and loading caused by lateral movement of soil. A nonlinear pile-soil interface element with the ability to represent a hardening or softening plastic response prior to reaching an ultimate state was incorporated. With the program, 4 failure modes can be determined: flow of the soil slide past an intact stationary pile; rotation of the pile with the soil at failure along the full pile length; translation of the pile with the sliding soil, resulting in failure of the supporting soil; and the long-pile mode, in which the maximum bending moment in the pile reaches the yield moment of the pile before complete development of the other 3 modes. Theoretical solutions for a realistic hypothetical offshore ...
As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual components. These results will be used to guide the development of ...
A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be ...
The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling devices and buildings. ...
Decreasing the aperture of a solar central receiver operating at high temperatures contributes significantly to the increase of the efficiency of energy absorption. However, decreasing the aperture also decreases the collection efficiency. A simple solution is using a 3D-CPC as secondary element for augmenting the energy collection, while the aperture can remain relatively small. Nevertheless, the receiver aperture as well as the secondary concentrator are usually rather large. For practical considerations an approximate solution may be chosen at times, designing the concentrator by a series of truncated cones. However, in particular cases, the solution of truncated cones remains expensive and unpractical and therefore the authors designed a CPC approximated by a series of trapezoidal planar facets. Under technical restrictions, there is an optimum for choosing the partition of the pure-CPC in truncated pyramids and the paper presents the ...
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)
The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.
Typical receiver processing, targeting always the best achievable bit error rate performance, can result in a waste of resources, especially, when the transmission conditions are such that the best performance is orders of magnitude better than the required. In this work, a processing framework is proposed which allows adjusting the processing requirements to the transmission conditions and the required bit error rate. It applies a-posteriori probability receivers operating over multiple-input multiple-output channels. It is demonstrated that significant complexity savings can be achieved both at the soft, sphere-decoder based detector and the channel decoder with only minor modifications.
Josephson effect heterodyne mixers with external local oscillators are very promising low noise mm-wave receivers for applications such as radio astronomy. Experiments at 36 GHz have shown that both the noise and the conversion efficiency of mixers made using Nb point contacts are in quantitative agreement with values calculated from the resistively shunted junction (RSJ) model. Preliminary measurements at 140 GHz suggest that this agreement extends to higher frequencies. In this paper the theoretical limits to the sensitivity of such receivers are explored as a function of the signal frequency. (Auth.).
Asymmetrical solar concentrators may offer significant advantages over symmetrical ones by the higher yearly average energy input per unit aperture area and the wider range of flexibilities in the design and operation. This paper describes the design, construction and performance evaluation of a non-parabolic asymmetrical solar concentrator with an evacuated receiver. The concentrator has a concentration ratio of 3.25 and a theoretical optical efficiency of 0.67. Collector efficiency test results are presented and compared with another similar concentrator without an evacuated receiver.
In an ideal system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun rays fall on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions are not realizable in practice; in this case, the parabolic dish system is called real system. In this paper a procedure for analysing the flux distribution on the receiver internal surfaces is presented for a cavity receiver with a real parabolic dish collector. First, the theoretical principles are discussed. Then the effect of the inaccuracy in the collector and in the sun tracking on the insolation pattern is described using an example.
Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiences, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.
Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiencies, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.
An analytical model is presented which enables the estimation of convective losses from cavity receivers. Evidence from solar experiments is used to test the hypothesized mechanisms. The analytical results and experimental evidence indicate that the convective loss from cavity receivers is appreciable. The model indicates that the influences of the wind on the convective loss at normal operating conditions are minimal. It also shows that the internal thermal resistance, i.e. the ability to heat the air inside the cavity, are of importance. Buoyancy induced flows are, on the other hand, effective in transferring energy across the aperture. 8 refs.
A simple analytical model has been developed in order to provide a framework for designing experimental programs for convective loss determinations, for analyzing available experimental data from solar receiver test programs, and for estimating the convective loss at a relatively small cost. Analytical results and experimental evidence indicate that the convective loss from cavity receivers is appreciable, while the effects of wind on the convective loss under normal operating conditions are minimal. The proposed analytical model provides a means of determining the relative importance of the internal resistances and predicting the bulk air temperature within the convective zone inside the cavity.
Radioactive waste shipping and receiving facilities presently planned for commercial and defence high level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. ...
Radioactive waste shipping and receiving facilities presently planned for commercial and defense high-level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations, suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner.
Radioactive waste shipping and receiving facilities presently planned for commercial and defense nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. Unacceptable personnel exposure to ionizing radiation is projected to occur if current limits for radiation levels at the cask surface and current handling methods are used. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels, while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. 6 refs., 12 ...
Purpose of reviewOsteonecrosis of the Jaw (ONJ) in an uncommon condition noted to occur in patients with cancer receiving intravenous bisphosphonates. The etiology...Full Text Available
BackgroundProfessionalism is a critical quality for physicians to possess. Physician professionalism has received increased attention in recent years, with many authorities suggesting...Full Text Available
... 4302, and to the Office of Management and Budget, Paper-work ... link coverage areas, so it is possible to receive your own ... mestic Ku-band satellite. ...
Background:Prolonged mechanical ventilation is increasingly common. It is expensive and associated with significant morbidity and mortality. Our objective is to comprehensively characterize...Full Text Available
... Received: February 22, 2010; Accepted: August 17, 2010 Hygrophila polysperma (Roxb.) T. Anderson. (ACANTHACEAE) Berkeley County: central part ... This is the first report for South Carolina. Hygrophila...
A new kind of receiver-reactor for high-temperature solar furnaces is proposed. The main body of the receiver component is an ellipsoid of revolution with specularly reflecting inner walls. The reactor component, a crucible, is placed at one focal point and the aperture at the other. With this arrangement, substantially all of the incident radiation from the concentrator should reach the reactor directly or after one reflection from the cavity walls. An analysis of the radiative exchange among the surfaces is presented. The analysis provides a tool for a parametric study and optimization of the design. It is found that, in contrast to that of conventional well-insulated cavity receivers, its collection efficiency is not very sensitive to the size of its aperture.
A module is described with a receiver having a solar energy acceptance opening and supported by a mounting ring along the optic axis of a parabolic mirror in coaxial alignment for receiving solar energy from the mirror, and a solar flux modulator plate for varying the quantity of solar energy flux received by the acceptance opening of the module. The modulator plate is characterized by an annular, plate-like body, the internal diameter of which is equal to or slightly greater than the diameter of the solar energy acceptance opening of the receiver. Slave cylinders are connected to the modulator plate for supporting the plate for axial displacement along the axis of the mirror thereby shading the opening with respect to solar energy flux reflected from the surface of the mirror to the solar energy acceptance opening.
Abstract While substantial attention has been paid to the issue of sexual dysfunction in men on chronic dialysis, less is known about this problem in women with end-stage renal disease. We sought to assess sexual dysfunction in women on chronic dialysis and determine whether patients discuss this problem with their providers and receive treatment. We prospectively enrolled women receiving chronic hemodialysis or peritoneal dialysis in Pittsburgh, PA. We asked patients to complete the 19-item Female Sexual Function Index (FSFI) to assess sexual function and a 5-item survey that assessed whether patients had discussed sexual dysfunction with their providers and/or received treatment for this problem in the past. We enrolled 66 patients; 59 (89%) on hemodialysis and 7 (11%) on peritoneal dial...
Rationale and ObjectivesSample-size estimation is an important consideration when planning a receiver operating characteristic (ROC) study. The aim of this work was...Full Text Available
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this arrangement, a high ...
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positioned in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts infrared radiation from the front of the absorber. With this arrangement, a high ...
The visual outcome, histopathology, and electrodiagnostic tests of a man with a malignant melanoma of the choroid who received foveal argon laser photocoagulation prior to enucleatiion are described....Full Text Available
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
This invention is an improved solar energy cavity receiver for exposing materials and components to high temperatures. The receiver includes a housing having an internal reflective surface defining a cavity and having an inlet for admitting solar radiation thereto. A photothermal absorber is positiond in the cavity to receive radiation from the inlet. A reflective baffle is positioned between the absorber and the inlet to severely restrict the re-radiation of energy through the inlet. The front surface of the baffle defines a narrow annulus with the internal reflective surface of the housing. The front surface of the baffle is contoured to reflect incoming radiation onto the internal surface of the housing, from which it is reflected through the annulus and onto the front surface of the absorber. The back surface of the baffle intercepts radiation from the front of the absorber. With this arrangement, a high percentage of ...
Our global impact is finally receiving the scientific attention it deserves. The outcome will largely determine the future course of evolution. Human-modified ecosystems are shaped by our activities...Full Text Available
Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating ...
... s guides and "how-to" videos and other materials, and 7. Receive continuing support from GLOBE's ... and educational materials that result from international proposals in its materials and support ...
BackgroundGender is a critically important moderator of psychopathology. However, gender similarities and differences in body dysmorphic disorder (BDD) have received...Full Text Available
An elderly man receiving chlorambucil for chronic lymphatic leukaemia developed focal fits. The onset and frequency were dose related. There was no evidence of metabolic disturbance or of meningeal...Full Text Available
... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...
PurposeTo determine the dosimetric impact of inter-fraction anatomical movements in prostate cancer patients receiving proton therapy.Full Text Available
In 1976 the design and fabrication began of an 1 MWt Bench Model Solar Receiver (BMSR) to demonstrate and further develop the ceramic tube central receiver concept. Although many of the properties of silicon carbide are well documented, this material has never been utilized in an application of this type and size. Further investigation was undertaken to confirm the choice of silicon carbide against available metals and other ceramic materials. The BMSR is configured for testing at the Department of Energy's Central Receiver Test Facility in Albuquerque, New Mexico. Design and fabrication of the BMSR are highlighted in this report. Completion and testing of the BMSR are planned for the next phase of the project.
Phytoremediation, a technology using plants to remediate or stabilize contaminants in soil, groundwater, or sediments, has recently received a great deal of attention from regulators, consultants, responsible parties, and stakeholders. phytoremediation ha...
Abstract This study explored the demographic and diagnostic features of children who were currently receiving antipsychotics compared to children who were receiving other psychotropics in a cohort of children with and without elevated symptoms of mania (ESM). Participants were recruited from 10 child outpatient mental health clinics associated with four universities. Guardians with children between 6?12 years who presented for new clinical evaluations completed the Parent General Behavior Inventory-10 Item Mania Scale (PGBI-10M). All children who scored ?12 on the PGBI-10M and a select demographically matched comparison group of patients who scored ?11 were invited to participate. Children were divided into two groups: those receiving at least one antipsychotic medication and those receivi...
The need to increase efficiency of volumetric receivers for use in solar power plants by reducing reradiation losses and increasing the ``volumetric effect`` has promoted the idea of a receiver with tapered ducts. These seems to be very promising since higher efficiency and considerable saving of material can be achieved, as compared to conventional receivers perforated with ducts of constant cross-section. A finite element program is being developed to calculate stationary heat transfer in the tapered ducts by free and forced convection in the gas flow, conduction in walls and in the gas, and solar and thermal radiation. Gas and wall temperatures are considered to be varying only in the flow direction. In order to perform the highly nonlinear calculations of radiative exchange, the exact knowledge of the view factors is necessary. The aim of the present work is to evaluate analytically the view factors in tapered ducts.
... earns money through receiving protection funds from embattled ... relationship between the TTP and LI ... relevant considering that Pakistan's military is ...
She completed Northern Arizona University's post-baccalaureate program, and received her M.E.d from Arizona State University with a focus in cognitive ...
... mounted new operations against the TTP stronghold in ... was the fourth tranche of Pakistan's IMF-backed ... and brought the total funds received by ...
Research in concentrated thermal solar power plants of all types and, in particular, those based on central receiver, namely solar tower plants, has experienced great impetus in the last decade, reaching full commercial operation with the PS10 plant in Spain. In spite of previous demonstration plants testing different receivers and power cycle layouts, this first commercial power plant adopted a cavity receiver generating saturated steam and therefore penalising cycle efficiency in order to gain plant reliability. According to the experience gained, if a competitive Levelised Cost of Electricity is to be reached, capital and maintenance costs must be reduced and efficiencies must be increased. To achieve these goals, modifying the power cycle is deemed essential, whether using superheated ...
Variations in thermal energy costs of single module solar central receiver systems using one, two, three, and four aperture cavity receivers at a location corresponding to Barstow, California are investigated for nominal power ratings ranging from 100 MWt to 900 MWt. Also considered are the effects on energy costs of changes in plant latitude, and the energy cost impact of the replacement of the single module design with multiple connected modules producing the same thermal power. The results, obtained with the aid of the DELSOL2 computer program, indicate that solar central receiver plant energy costs are insensitive functions of power level, latitude, and configuration. No clear cost of energy advantage between single and multiple modules is seen.
A cone concentrator combined with a solar cavity receiver is presented and its performance compared to a single cavity receiver. For both cases the available heat sink within the receiver is calculated. The cone concentrator suffers from a high amount of rejected rays if the exit aperture is made too small. A larger exit aperture on the other hand increases the thermal losses of the cavity. The optimum cone geometry therefore has to be found taking also into account a model of the cavity. Different operating temperatures and different values of absorption coefficients of the cavity walls are considered. A cone concentrator was built and tested at the solar furnace in Cologne. It transmits 97 percent of the rays entering the entrance aperture, which is in exact agreement with the theoretical predictions. (author)
The study presented in this thesis is a contribution about the analysis of failures modes of electrolytic capacitors and thyristors. The studied components are main elements of the protection system of the superconductive magnets of the LHC. The study of the ageing of the electrolytic capacitors has shown that their reliability is strongly related to their technological characteristic. Evolution of their principal indicator of ageing (ESR) can be modeled according to different laws chosen according to their running mode. It appears that the prediction of failure of these components other than that due to wear can be only statistical taking into account the many causes of failure involving various modes of failure. In order to be able to evaluate influence of the ageing of the electrolytic capacitors on a system, simple models taking into account this parameters as well as the effective temperature of ...
Customer Relationship Management (CRM) systems can help organizations manage customer interactions more effectively. Like many new technologies, CRM has been accompanied by vendor hype and stories of implementation failure. Work on critical success factors (CSFs) should encourage more appropriate implementation practice; however many CSF studies conclude with a list of factors but provide little further guidance. In particular, there is a need for stronger theoretical models of the entire CRM innovation process which can be used by managers to understand better the underlying causes of success and failure. This paper adopts a novel approach to this problem by firstly developing a conceptual model of CRM innovation and then converting this model into a dynamic simulation model. Some early s...
A series of six transient tests was performed on FFTF irradiated fuel pins to demonstrate their transient performance capability. The tests were performed in the TREAT reactor using sodium loops and instrumented test trains. The TEMECH computer code was used to design overpower transients which would simulate FFTF fuel pin thermal conditions during slow and fast unprotected transients. Some tests were run to substantial overpower levels but terminated prior to fuel pin failure, while other tests were intentionally extended to fuel failure to establish failure thresholds and characteristics. Post-test examination data provided significant cladding strain and fuel melting information used for performance code calibration and validation. These data showed that cladding damage caused by fuel melting is related to the steady state condition of the fuel.
The fatigue life variability of the #alpha#+#beta# titanium alloy, Ti-6Al-2Sn-4Zr-6Mo increased with decreasing stress level. The variability in life was found to be due to segregation of lives due to two failure mechanisms. A bimodal cumulative distribution model was shown to accurately describe the combined failure modes. The nominal failure processes for the two regimes were similar, with crack nucleation occurring in equiaxed #alpha#p particles, irrespective of life or stress level. However the variability in life was not controlled by the size of the crack-nucleating #alpha#p, but rather by the ability of the material to distribute deformation and avoid early crack nucleation.
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded that corrosion-induced leaks can be prevented by using anodic protection and baked phenolic coating technologies. 23 refs., 9 ...
Design rules for robustness require insensitivity to local failure and the prevention of progressive collapse. This is often verified by applying the load case ''removal of a limited part of the structure''. This paper will evaluate typical structural systems for large-span timber roof structures against these requirements, comparing the results against typical reasons for damages and failures. Applying the finding that most failures of timber structures are not caused by random occurrences or local defects, but by global (repetitive) defects (e.g. from systematic mistakes), it is shown that the objective of load transfer-often mentioned as preferable-should be critically analysed for such structures. Based on these findings, proposals for structural systems and details towards a robust de...
The aim of the risk assessment consists of a comparative security evaluation for the SNR-300 and the PWR Biblis B. The failure analysis focusses on the reactor core; in addition, possible fission product release from the spent fuel pits is examined. By reliability analyses, the frequency of events leading to incidents is determined together with the probability of core destruction. In the accident analysis, the kind and frequency of failure of the activity barriers, i.e., primary system (reactorvessel) and inner and outer containment are investigated for the various incident sequences. The radionuclide release into the environment is classified into five different release categories. Besides internal failures, external causes (especially earthquakes and plane crashes) are considered under the aspect of their risk contribution. (RF).
This paper presents a probabilistic approach for structural robustness assessment for a timber structure built a few years ago. The robustness analysis is based on a structural reliability based framework for robustness and a simplified mechanical system modelling of a timber truss system. A complex timber structure with a large number of failure modes is modelled with only a few dominant failure modes. First, a component based robustness analysis is performed based on the reliability indices of the remaining elements after the removal of selected critical elements. The robustness is expressed and evaluated by a robustness index. Next, the robustness is assessed using system reliability indices where the probabilistic failure model is modelled by a series system of parallel systems.
Reference failures, and their increase in affectively negative conditions (known as affective reactivity of speech), are more frequently observed in schizophrenia patients than in normal controls, but no information is available comparing schizophrenia with depression, ie, a mental disorder closely linked to the concept of affective reactivity. To address this gap in the literature, the present study compared 24 schizophrenia inpatients, 21 unipolar depression inpatients and 21 normal controls. Two 10-minute conversational speech samples (1 on negative and 1 on positive memories) were collected from each patient. The transcripts of the audiotaped interviews were analyzed blindly for frequencies of 6 types of referential failures, employing the Communication Disturbances Index, adapted for ...
Premature Failure of a Riata Defibrillator Lead. A 63-year-old woman with a St. Jude Medical Riata 1570 right ventricular lead complained of intermittent hiccups 2 months after implant. Interrogation revealed elevated pacing threshold and diaphragmatic stimulation. Pacing and shock lead impedances remained stable. No inappropriate sensing was noted. Fluoroscopic examination of the lead revealed a thin radio-opaque wire seen between the 2 defibrillator coils away from the main body of the lead. After extraction, a tear in the insulation of the lead was noted allowing the inner wire to protrude. This case illustrates a novel mechanism of insulation failure without inappropriate sensing or impedance change.-(J Cardiovasc Electrophysiol, Vol. 22, pp. 1070-1072, September 2011)
In general, macroscopic material failure is a manifestation of irreversible changes at the microscopic level. Many tissues, which may appear to be macroscopically homogeneous, are, at a fundamental microscopic level, a composite material. For example, cornea is composed of a hyaluronic acid matrix in which layers of collagen fibers are overlaid in a crossing pattern. The points where the collagen fibers intersect are potential nucleation sites for microscopic defects, which under the action of tensile stress, nucleate, grow and coalesce to form macroscopic failure planes, or spall planes. Using a model based on microstructural evolution, this paper examines the failure process during photoablation. Specifically, the paper describes a physically motivated, micromechanical model based on the nucleation and growth of spherical voids. This model is then used to simulate photoablation of cornea. Potential for using this model to ...
Twenty-two out of 31 patients with chronic renal failure and secondary hyperparathyroidism who underwent parathyroidectomy before operation underwent non-invasive image diagnosis of parathyroid glands by computed tomography (CT), scintigraphy with /sup 201/TlCl and /sup 99m/TcO/sup 4 +/, and/or ultrasonography. CT visualized 39 of 45 parathyroid glands (86.7%), weighing more than 500 mg. Scintigraphy with a subtraction method using a computer performed the diagnosis in 19 of 27 glands (70.4%). Ultrasonography detected 21 of 27 glands (77.8%). Image diagnosis was also useful in the postoperative follow-up study. The non-invasive image diagnosis of parathyroid glands in patients with chronic renal failure is thus valuable for 1) definite diagnosis of secondary hyperparathyroidism, 2) localization, and 3) diagnosis for effectiveness of conservative treatment.
An availability assessment of the principal systems of the Heber Geothermal Power Plant has been carried out based on the final issue of the process descriptions, process flow diagrams, and the approved for design P and IDs prepared by Fluor Power Services, Inc. (FPS). The principal systems are those which contribute most to plant unavailability. The plant equivalent availability, considering forced and deferred corrective maintenance outages, was computed using a 91 state Markov model to represent the 29 principal system failure configurations and their significant combinations. The failure configurations and associated failure and repair rates were defined from system/subsystem availability assessments that were conducted using the availability assessments based on the EPRI GO methodology and availability block diagram models. The availability and unavailability ranking of the systems and major equipment is presented.
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
The purpose of this project was to develop improved dynamic failure models for brittle materials (primarily ceramics). The approach to developing these failure models was to establish a database (ACERAM) in which fundamental material properties and processing information could be directly correlated with ballistic performance data. Under this contract, a comprehensive literature search was conducted, many contacts were established in the armor/anti-armor research and development community, and database development was undertaken. A more limited project was also undertaken to assess and compare the effects of material properties and penetration mechanisms on the ballistic performance of depleted uranium and tungsten alloy penetrators.
Analyses were performed of the safety-related performance of the reactor protection system (RPS) at U.S. Westinghouse and General Electric commercial reactors during the period 1984 through 1995. RPS operational data from these reactors were collected from the Nuclear Plant Reliability Data System (NPRDS) and Licensee Event Reports (LER). The common-cause failure (CCF) modeling in the fault trees developed for these studies and the analysis and use of common-cause failure data were sophisticated, state-of-the-art efforts. The overall CCF effort helped to test and expand the limits of the U.S. Nuclear Regulatory Commission's CCF methodology.
BackgroundAlthough self-expandable metal stent (SEMS) insertion is widely used for relief of malignant colorectal obstructions, the immediate technical and clinical failure rates of SEMSs and the associated risk factors remain largely unknown. ObjectiveTo identify rates and factors predictive of technical and clinical failure of SEMSs when their use is attempted for the decompression of malignant colorectal obstruction. DesignRetrospective chart review. SettingA tertiary-care academic medical center in South Korea. PatientsThis study involved a total of 412 patients with malignant colorectal obstruction in whom SEMS insertion was attempted. InterventionPlacement of colonic SEMSs. Main Outcome MeasurementsTechnical success and immediate and long-term clinical success rates. ResultsTechnical...
The interest in efficient solar collector design has stimulated investigation of two-dimensional (trough-like) cavity structures. A novel principle for designing cavity enclosures is described. The present method maintains high transmission albeit at the expense of some concentration in the presence of gaps as large as the radius between reflector and receiver. The new method can be applied to advantage to nonimaging concentrator design as well as to line focus concentrators.
This volume on specifications for the Saguaro Power Plant includes the following: subsystem interface definition document; solar collector subsystem specification; receiver specification; thermal energy storage specification; solar steam generator specification; and master control system specification.
A summary is provided of the first of three years of experimental and theoretical research on free-forced convection flows in cavity-type solar receivers. New experimental and theoretical results are presented and discussed. The implication of these findings, with respect to the future thrust of the research program, is clarified as well as is possible at the present time. Following various related conclusions a summary and tentative schedule of work projected for year two of research are presented.
A numerical calculation procedure applicable to cavity-type receiver configurations and flow conditions was developed. Flow visualization experiments were performed, and experimental measurements of quantities valuable for the development of the numerical calculation procedure were made. The investigation is focussed on a configuration which is strongly two-dimensional in the mean flow structure (but turbulent in a truly three-dimensional sense). (LEW)
During four years of operation at the Central Receiver Test Facility (CRTF) ceramics have performed well in cyclic solar flux densities of less than 30 W/cm/sup 2/. Above 100 W/cm/sup 2/, serious limitations exist. Important application considerations include: the geometry, cyclic and long time exposures, flux density gradients, thermal shock, weathering, and soiling.
An investigation of natural convection losses from cavity-type solar central receivers is described and results are given. The approach followed was that of a fundamental experimental study in a simple cavity subject to well controlled boundary conditions. The Laser Doppler Velocimeter proved to be a useful technique to measure the velocity profiles associated with natural convection. Visualization techniques provided an understanding of the general behavior of the flow, particularly in three dimensional experiments. Experiments on systems of high Rayleigh numbers are described. (LEW)
A coherent lidar system has been constructed for the measurement of alpha particles in a burning plasma. The lidar system consists of a pulsed CO{sub 2} laser transmitter and a heterodyne receiver. The receiver local oscillator is a cw, sequence-band CO{sub 2} laser operating with a 63.23 GHz offset from the transmitter.
BackgroundModern metal-on-metal hip resurfacing implants are being increasingly used for young and active patients, although the long-term outcome and failure mechanisms of these...Full Text Available
Albeit the considerable progress that has been made both in our understanding of the pathophysiology of acute renal failure (ARF) and in its treatment (continuous renal replacement therapies), the morbidity...Full Text Available
HIV-1 nonsubtype B variants account for the majority of HIV infections worldwide. Drug resistance in individuals who have never undergone antiretroviral therapy can lead to early failure and...Full Text Available
In a group of 32 patients with terminal renal failure the initial hypocalcaemia was corrected after two months' adequate maintenance haemodialysis. In seven patients hypercalcaemia occurred with a...Full Text Available
BackgroundIsoproterenol-induced cardiac hypertrophy in mice has been used in a number of studies to model human cardiac disease. In this study, we compared the transcriptional response...Full Text Available
Background and purpose It has been speculated that the prevalence of metal allergy may be higher in patients with implant failure. We compared the prevalence and cause of revisions following...Full Text Available
Aging is a risk factor for heart failure, which is a leading cause of death world-wide. Elderly patients are more likely than young patients to experience a myocardial infarction (MI) and are...Full Text Available
BackgroundThere is a strong inverse relationship between final vessel diameter and subsequent risk of treatment failure after coronary stent deployment. The aim of this study was...Full Text Available
Progress is reported in the following areas: radioactivity control technology, FFTF sodium characterization system, corrosion and process control, and fuel failure monitoring systems for FFTF and CRBRP. (JWR)
BackgroundContrast-induced nephropathy is the leading cause of in-hospital acute renal failure. This side effect of contrast agents leads to increased morbidity, mortality, and health...Full Text Available
Xylem failure via gas embolism (cavitation) induced by water stress was investigated in the palm Rhapis excelsa (Thumb.) Henry. Xylem embolism in excised stems and petioles was detected...Full Text Available
Failures in cortical control of fronto-striatal neural circuits may underpin impulsive and compulsive acts. In this narrative review, we explore these behaviors from the perspective of neural processes...Full Text Available
Acetaminophen (APAP) toxicity is the most common drug-induced cause of acute liver failure in the United States. The only available treatment, N-acetylcysteine (NAC), has a limited...Full Text Available
It is well known that the lightning protection of transmission lines is exclusively relying on their correct initial design. Although detailed engineering studies are usually performed by electric power utilities for the design of new transmission lines, there are reported cases where the design is based simply on tradition or on utilities' standardization policy. In this paper, the lightning protection of high-voltage transmission lines is faced as an optimization problem where optimum design parameters are calculated for the lines, relating their cost with the lightning failures' cost, aiming to reduce or even eliminate lightning failures. The optimization method considers all the available protection means, i.e. ground wires and surge arresters. In order to validate the effectiveness of the proposed method, it is applied on several operating Hellenic transmission lines of 150 kV carefully selected among others due to their ...
In this work, a model for determining the optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 is developed, which is to minimize economic loss caused by inadvertent trip and the system failure. This model uses cost benefit analysis method and the part for optimal inspection period considers the human error. The model is based on three factors as follows: (i) The cumulative failure distribution function of the safety system, (ii) The probability that the safety system does not operate due to failure of the system or human error when the safety system is needed at an emergency condition and (iii) The average probability that the reactor is tripped due to the failure of system components or human error. The model then is applied to evaluate the safety system in Wolsung Nuclear Power Plant Unit 1. The optimal replacement periods which are calculated with ...
The pharmacokinetic parameters of amikacin and ceftazidime were assessed in four patients undergoing hemofiltration for septic shock. The parameters were assessed during hemofiltration and in the interim...Full Text Available
Bone remodeling is necessary to avoid microdamage accumulation, which could lead to whole-bone failure. Previous studies have shown that this bone-repair mechanism is triggered by osteocyte apoptosis....Full Text Available
BackgroundGene expression profiling and the analysis of protein-protein interaction (PPI) networks may support the identification of disease bio-markers and potential drug targets....Full Text Available
Silver-haired bat rabies virus (SHBRV) infection induces a strong virus-specific immune response in the periphery of the host, but death is common due to the failure to open the blood-brain barrier...Full Text Available
Serial studies of iron transport in patients on maintenance dialysis showed normal or raised values in almost all subjects and a transient increase soon after the start of dialysis in three. These...Full Text Available
The presence of DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the...Full Text Available
AIMS:To investigate the effect of carnitine supplementation on alcoholic malnourished rats' hepatic nitrogen content.METHODS:Malnourished rats, on...Full Text Available
ObjectivesThis studys examined the relationship between substance use disorder (SUD) and intimate partner violence screening (IPV) and management practices in the...Full Text Available
In this paper, an investigation was performed on a failure pressure vessel, which was as an anti-freezing heater for General Gas Storage and Distribution (SGZ) system. Evident and serious deformation was observed on the body of the vessel. A metallurgical investigation was conducted to establish the mechanism and cause of deformation of the anti-freezing heater at Daya Bay PWR station in China. The investigation, which was performed on specimens cut from the most serious area deformed of the vessel, included macroscopic examination and microscopy examination. The results of the examinations showed that some lamellar pearlite in the microstructure were already spheroidized. It was confirmed that the vessel was operated at high temperature. Stress analysis for the vessel was conducted. And it was confirmed that, in ideal conditions, the vessel would be deformed at around 420 C. The overall results of the investigation showed that the failure of ...
The probabilistic external events analysis performed for the Savannah River Site K-reactor PRA considered many different events which are generally perceived to be external'' to the reactor and its systems, such as fires, floods, seismic events, and transportation accidents (as well as many others). Events which have been shown to be significant contributors to risk include seismic events, tornados, a crane failure scenario, fires and dam failures. The total contribution to the core melt frequency from external initiators has been found to be 2.2 {times} 10{sup {minus}4} per year, from which seismic events are the major contributor (1.2 {times} 10{sup {minus}4} per year). Fire initiated events contribute 1.4 {times} 10{sup {minus}7} per year, tornados 5.8 {times} 10{sup {minus}7} per year, dam failures 1.5 {times} 10{sup {minus}6} per year and the crane failure scenario less than ...
The nephrotoxicity of cefoxitin was studied in a rat model of impaired renal function. Two levels of renal impairment were produced: "moderate," with blood urea concentrations of 100 to 150 mg/100 ml...Full Text Available
A micro-mechanistic understanding of bone fracture thatencompasses how cracks interact with the underlying microstructure anddefines their local failure mode is lacking, despite extensive research nthe response of bone to a variety of factors like aging, loading, and/ordisease.
Present methods for planning reliability improvement of launch vehicles are reviewed. A theoretical criterion for optimum allocation of resources for reliability improvement exists that requires equal marginal failure reduction for all elements to be impr...
The goal of this study was to evaluate topics used to troubleshoot circuit boards with known or suspected thermally intermittent components. Failure modes for thermally intermittent components are typically mechanical defects, such as cracks in solder paths or joints, or broken b...
Acetaminophen (APAP), a widely used analgesic and antipyretic that is considered to be relatively safe at recommended doses, is the leading cause of drug-induced liver failure in the United States....Full Text Available
The performance of more than 3,000 offshore platforms in the Gulf of Mexico was observed during the passage of Hurricane Andrew in August 1992. This event provided an opportunity to test the procedures used for platform analysis and design. A global bias was inferred for overall platform capacity and loads in the Andrew Joint Industry Project (JIP) Phase 1. It was predicted that the pile foundations of several platforms should have failed, but did not. These results indicated that the biases specific to foundation failure modes may be higher than those of jacket failure modes. The biases in predictions of foundation failure modes were therefore investigated further in this study. The work included capacity analysis and calibration of predictions with the observed behavior for 3 jacket platforms and 3 caissons using Bayesian updating. Bias factors for two foundation failure modes, lateral shear and ...
Research is in progress to obtain a satisfactory creep ductility for alloy 800 when used as heat exchanger material in sodium-cooled fast reactors (LMFBR). The creep test characteristics at present available show that a pronounced tendency to reduced elongation by creep failure may arise after prolonged testing in the 500-700 deg C temperature range. This phenomenon is now agreed to be primarily inherent to the conditions for Ni_3(Ti,Al) precipitation in the material and hence to the Ti and Al concentrations. By structural studies and hardness measurements on material subjected to creep tests and taken from a large number of castings, the relationship was established between the (Ti+Al) content and the structural hardness effect of Ni_3(Ti,Al) at 600 deg C. Below a certain Ti+Al concentration, no precipitation occurs and hence the creep ductility to failure can be improved considerably by limiting the allowed Ti+Al content in the material, ...
Myocarditis, often initiated by viral infection, may progress to autoimmune inflammatory heart disease, dilated cardiomyopathy and heart failure. Although cardiac myosin is a dominant autoantigen...Full Text Available
BackgroundThe elevated serum and peritoneal cytokine concentrations responsible for the systemic response syndrome (SIRS) and multiorgan failure in patients with severe acute pancreatitis...Full Text Available
The measurement of bone loss in patients undergoing maintenance dialysis over a period of two and a half years is reported. The tendency to lose bone is a likely event in renal failure, but depends...Full Text Available
Failure of bone under monotonic and cyclic loading is related to the bone mineral density, the quality of the bone matrix and the evolution of microcracks. The theory of linear elastic fracture...Full Text Available
Background: The causes of elevated B-Type natriuretic peptide (BNP) levels are multifactorial. Renal dysfunction has been shown to affect BNP levels in some studies and...Full Text Available
Evaluating the systolic function of the left ventricle (LV) is important in the hemodynamic management of the critically ill patients with circulatory failure. Echocardiography is considered the standard...Full Text Available
Anxiety may cause adverse outcomes through physiologic pathways in patients with cardiac disease. The purpose of this dissertation was to investigate anxiety and its correlates in persons with acute myocardial infarction (AMI) and heart failure (HF). The ...
The free radical theory of ageing posits that accrual of oxidative damage underlies the increased cellular, tissue and organ dysfunction and failure associated with advanced age. In support of this...Full Text Available
A case of severe intractable angina pectoris with normal angiography is presented. Following video assisted thoracic sympathectomy the patient died of heart failure. Microvascular cardiac amyloidosis...Full Text Available
ObjectiveThe purpose of this study is to identify the factors affecting the failure of trials (<50% pain reduction in pain for trial period) to improve success rate of spinal...Full Text Available
BackgroundMale infertility is a common cause of reproductive failure in humans. In mice, targeted deletions of the genes coding for FKBP6 or FKBP52, members of the FK506 binding...Full Text Available
Due to the recent catastrophic energy system failures in California along with those in the North-Eastern US and Southern Canada, London, and Italy, the time has come to proclaim the failure of deregulation, privatization or liberalization and propose a new energy system. This book shows in the first section, how five precipitating forces led to the deregulation debacle in California: (1) major technological changes and commercialization, (2) regulatory needs mismatched to societal adjustments, (3) inadequate and flawed economic models, (4) lack of vision, goals, and planning leading to energy failures, and (5) failure and lack of economic regional development. The second half of the book, examines how 'civic market', new economic models, and planning for complexity as sustainable economic development transformed in California, the same five forces to create an 'agile energy ...
Congenital diaphragmatic hernia (CDH) is described as (1) failure of diaphragmatic closure at development, (2) presence of herniated abdominal contents into chest and (3) pulmonary hypoplasia. Usually,...Full Text Available
Properly quantified performance of a solar-thermal cavity receiver must not only account for the energy gains and losses as dictated by the First Law of thermodynamics, but it must also account for the quality of that energy. However, energy quality can only be determined from the Second Law. In this paper an equation for the Second-Law efficiency of a cavity receiver is derived from the definition of available energy or availability (occassionally called exergy), which is a thermodynamic property that measures the maximum amount of work obtainable when a system is allowed to come into unrestrained equilibrium with the surrounding environment. The fundamental concepts of the entropy and availability of radiation are explored from which a convenient relationship among the reflected cone half angle, the insolation, and the concentrator geometric characteristics is developed as part of the derivation of the Second-Law efficiency. A comparison is ...
Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, ...
The work reported in this paper addresses the problem of structure-borne sound transmission between vibrating sources and ribbed-plate receiver structures. Vibrating sources, such as pumps, motors, fans, etc., transmit vibro-acoustic power, causing noise complaints by occupants in cars, trains, aircraft, buildings and/or material fatigue and damage. The transmission process is complicated in that sources transmit power through several contacts and by up to six components of excitation at each contact. The structure-borne sound power is a function of source activity, source mobility and receiver mobility, and all three quantities must be known to some degree. For non-homogeneous receiver structures, such as thin-plate cavity constructions or lightweight framed constructions, the sheathing plates are typically fastened to the framing members using bolts, screws or spot-welded joints. Hence the resulting system is a ...
A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal ...
A paraboloidal dish solar thermal power plant produces electrical energy by a two-step conversion process. The collector subsystem is composed of a two-axis tracking paraboloidal concentrator and a cavity receiver. The concentrator focuses intercepted sunlight (direct, normal insolation) into a cavity receiver whose aperture encircles the focal point of the concentrator. At the internal wall of the receiver the electromagnetic radiation is converted to thermal energy. A heat engine/generator assembly, which is mounted directly behind th receiver, then converts the thermal energy captured by the receiver to electricity. Developmental activity has been concentrated on relatively small power modules which employ 11- to 12-m-diam dishes to generate nominal power levels of approximately 20 kW. A comparison of advanced heat engines for use on the dish power module is presented in terms of ...
Based on a detailed analysis of the inter-relationship in the current, voltage, electromagnetic torque and ratio of the difference between the speed of rotor and the speed of rotary magnetic field to the later in the motor, the root cause was point out, which leads to the protection fuses' failure of the motor in the starting stage, which drives the turbine-generator set to rotate at low speed before its startup. Two solutions to avoid the situation are proposed, too. (authors)
High strain fatigue problem in steam turbine. Cyclic stress strain hysteresis loops and stress relaxation behaviour in 16 h dwell period tests. Variation of stress and strain during tests under nominally strain controlled conditions. Definition of test conditions and of criteria for crack initiation and failure. Comparison of reverse bend and push pull failure data. (orig.) 891 RW/orig. 892 RKD.
The TS-1 and TS-2 Transient Reactor Test Facility (TREAT) experiments were conducted on irradiated Fast Flux Test Facility (FFTF) fuel pins to characterize their failure behavior when subjected to hypothetical 5%/s transient overpower conditions. The TS-1 test employed a near-fresh (2 MWd/kg) fuel pin, while the TS-2 test used a medium-burnup (58 MWd/kg) fuel pin. Transient conditions were closely matched between the two experiments to provide a direct comparison of burnup effects on the failure response.
Analytical models for predicting the deformation and failure of composite sandwich panels subjected to blast and projectile impact loading are presented in this paper. The analytical predictions of the transient deformations and damage initiation in the composite sandwich panels were compared with finite element solutions using ABAQUS Explicit. For the blast model, the predicted transient deformation of the sandwich panel was within 7%of FEA results, while the predicted damage initiation using Hashin's composite failure criteria was about 15%higher than FEA results in most cases. For the high velocity impact model, the predicted transient deformations were within 20%of FEA results.
Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).
The nitric acid solution dissolving nuclear fuel material is transferred with the three way valve called VCV (VCV: vide-casse-vide in Fr.) using vacuum in the Tokai Reprocessing Plant. The initial VCV was not reliable because it had broken with in 1 or 2 years. The cause of failure was damage of the plastic diaphragms in the moving parts. Then, the new VCV valve with stainless-steel bellows was developed. There is no failure in moving parts in 20 years, therefore reliability is significantly improved. (author)
A large amount of radioactive waste has been stored safely at the Savannah River and Hanford sites over the past 46 years. The aim of this report is to review the experimental corrosion studies at Savannah River and Hanford with the intention of identifying the types and rates of corrosion encountered and indicate how these data contribute to tank failure predictions. The compositions of the High-Level Wastes, mild steels used in the construction of the waste tanks and degradation-modes particularly stress corrosion cracking and pitting are discussed. Current concerns at the Hanford Site are highlighted.
From the beginning, one of the most useful applications of Probabilistic Safety Assessment (PSA) is its use in evaluating the risk importance of changes to plant design, operations, or other plant conditions. Risk importance measures the impact of a change on the risk. Risk is defined as a combination of the likelihood of failure and consequence of the failure. The consequence can be safety system unavailability, core melt frequency, early release, or various other consequence measures. The goal in this PSA application is to evaluate the risk importance of an ISI process, as applied to plant piping systems. Two approaches can be taken in this evaluation: Current PSA Approach or the Blended Approach. Both are discussed here.
An integrated approach to the modelling of hydrogen assisted failure in 316L steel is presented. The approach includes experimental, fractographic, numerical and theoretical analysis of the phenomenon. The physical adequacy of the mechanical models of hydrogen embrittlement (notch extension model and notch cracking model) is discussed by comparing the virtual damage depth (theoretical) predicted by the models with the embrittled zone (microphysical) measured in the fractographic analysis by scanning electron microscopy. In addition, a numerical modelling of hydrogen diffusion is performed, concluding that bulk diffusion is not important in hydrogen embrittlement of 316L steel, so that hydrogen transport accelerated by the microdamage itself should be taken into account. (orig.)
Often, lifetime data come from experiments where failure times are grouped. The Weibull distribution is a popular distribution for modeling failure times. Maximum likelihood estimation (MLE) has outstanding large sample properties for the Weibull distribution. This article evaluates small sample properties of MLEs for grouped data. We evaluate sample size requirements for MLE asymptotic properties to take effect. We compare type I and type II censoring for pooled experiments and conclude that bias for the shape parameter estimate can be alarmingly high especially for type II censored data. Finally, we investigate the benefits of the pooled analysis.
Elastic and elasto-plastic modelling of indentation in CFRP cross-ply laminates has been performed. Detailed knowledge of the field solutions in the volume below the indentor forms the basis for the reported micromechanical interpretation of the observed damage in test specimens. The analysis shows that matrix cracks originate at sites of maximum tensile stress perpendicular to fibers. The predicted stress fields due to indentation show that stress concentrations occur in the interface between alternating plies. It is found that microcracking in this zone is a precursor to the observed failure. This analysis is supported by in-situ scanning electron microscopy during loading by a cylindrical indentor onto the laminate supported on a rigid substrate. The microscopy reveals microdamage in the region of interfacial tensile stress concentrations. The onset of indentation failure in these layered composites suggests that plastic interleaves would ...
Since the integrity of the containment penetrations was confirmed under accident management (AM) conditions in the former test, failure criteria tests and aerosol trapping tests were carried out using low-voltage modules and flange gaskets of an actual plant under severe accident (SA) conditions, without AM. The safety margin for failure temperature of the penetrations and the credit for fission product (FP) aerosol trapping effect along the leakage paths of the degraded penetrations were evaluated in the present tests. Failure temperature of the penetrations ranged from 270 to 300degC for low-voltage modules and 300 to 350degC for flange gaskets under 0.4 to 1.0 MPa conditions. Pressure dependency on failure temperature was small. This means that the safety margin of failure temperature under AM condition is more than 70degC. By introducing a equivalent leak area for the damaged ...
The absorption of solar heat and the attendant thermal and mechanical loadings on the tubes of cavity receivers depend predominantly on the flux distribution of the incident solar radiation. For an axially symmetric cavity receiver with a parabolic dish collector, it is simple to determine the insolation pattern on the receiver internal surfaces if the system is ideal. In such a system the surface of the dish is perfectly parabolic (no contour flaws are present), and the sun's central ray impinges on the dish surface parallel to the focal axis (no sun tracking flaws are present). These two conditions cannot be achieved in practice, and therefore the feasible parabolic dish system is referred to as a real system although, in actual fact, it is only an approximation to any actual system. The purpose of this paper is to devise calculation principles which permit analysis of a receiver designed for ...
The energy flux distribution at the aperture of cavity receivers is an important parameter that characterizes the performance of point-focusing solar concentrators. Together with simplifying assumptions about cavity absorptance, emittance, and convective losses, good estimates of the dish-receiver collection efficiency as a function of incident flux and effective cavity temperature can be obtained. For detailed design of cavity receivers, however, it is necessary to determine the incident flux distribution on the interior surfaces. This information is needed ultimately to determine the resulting energy fluxes to the working fluid, temperature distributions within the cavity, and receiver performance. Knowing the incident flux distributions provides the designer with insights such as where hot-spots are likely to occur, where heat exchange surfaces are needed, and where more detailed analysis might be ...
Progress in the worldwide capability of predicting the convective energy loss from solar central receivers is reviewed. The significant advances in the past three years have been in experimental areas. Baseline measurements of the convective heat transfer from large high-temperature surfaces, e.g., a flat plate and a cubical cavity, have been completed and empirical correlations have been obtained. Theoretical modeling activities have not kept pace with the experimental advances, however. Currently, the primary theoretical emphasis is the development and testing of turbulence models suitable for buoyant flows. Three major needs have been identified: the measurement of convective energy losses from operating solar central receivers; the continued development of theoretical models in spite of the relatively slow progress to date; and the quantification of the effects of atmospheric turbulence.
Anti-jamming techniques to improve Global Positioning System (GPS) receivers robustness have been mainly developed in military applications. None of civilian techniques can procure sufficient robustness against occasional or intentional jammers for civil GPS or GALILEO navigation receivers. The amplitude domain processing (ADP) filtering is a technique based upon Capon works and Neyman-Pearson theory. Several experiments concerning the ADP filtering have been considered at the 3DETSNAV division of LACIME laboratory at Ecole de technologie superieure (ETS), which have proved that the technique is reliable in order to eradicate powerful interference present in the spread spectrum signal. However, the results show that the ADP filter has a real limitation when submitted to multiple interferen...
Records of 154 patients with Ewing's sarcoma treated at the National Cancer Institute were reviewed to assess the incidence and risk of developing isolated central nervous system (CNS) Ewing's sarcoma. Sixty-two of the 154 patients had received CNS irradiation and intrathecal (i.t.) methotrexate as part of their initial therapy to prevent the occurrence of isolated CNS Ewing's sarcoma. The risk of developing isolate CNS Ewing's sarcoma was greatest within the first two years after diagnosis and was approximately 10%. The overall risk of CNS recurrence in the group of patients receiving DNS treatment was similar to the group receiving no therapy directed to the CNS. The occurrence of isolated CNS involvement was not prevented by the use of CNS irradiation and i.t. methotrexate. Because of a lack of efficacy to the CNS irradiation regimen, current treatment regimens do not include therapy directed to CNS.
Progress made during the first phase effort of the Solar-Thermal Full-System Experiment is summarized. This is one of a number of projects in the Solar-Thermal Subprogram involved with the development of solar central receiver hardware and systems for future use by utilities. The main emphasis is on systems that use Brayton-Cycle (gas turbine) equipment. The project summarized involves the planning and design of a complete Brayton-Cycle solar central receiver experimental system that would include all components of a commercial-size electric utility solar power plant. The objective of the overall project is to demonstrate the technical feasibility of a complete Brayton-Cycle, solar-fossil hybrid central receiver system. Major objectives of the Phase I effort summarized are to plan and design the experiment in detail and to organize a utility Test and Operating Group that would be directly involved in the development and ...
In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation of a loss of the ...
The document represents a specific type of discussion of existing methodologies for the creation and application of probabilistic safety assessment (PSA) in light of the EUR document summarizing requirements placed by Western European NPP operators on the future design of nuclear power plants. A partial goal of this discussion consists in mapping, from the PSA point of view, those selected design, operational and/or safety factors of future NPPs that may be entirely new or, at least, newly addressed. Therefore, the terms of reference for this stage were formulated as follows: Assess current level of knowledge and procedures in the analysis of factors and phenomena with a dominant influence upon operational safety of new generation reactors, especially in the following areas: (1) Phenomenology of failure types and mechanisms and reliability of conventional passive safety system components; (2) Phenomenology of failure types and mechanisms and ...
This paper presents a stochastic model and estimation procedure for analyzing the failure process of a repairable system. We consider repairable systems whose successive interfailure times reveal a significant dependence while showing an insignificant trend. Neither the renewal process nor the non-homogeneous Poisson process are adequate for modeling such failure processes. Especially when the interfailure times show a cyclic pattern, we may consider a switching of the regimes (states) governing the lifetime distribution of the system. We propose a Markov switching model describing the failure process for such a case. The model postulates that a finite number of states governs the distinct lifetime distributions, and the state makes transitions according to a discrete-time Markov chain. Each of the distinct lifetime distributions represents a failure type that may change after successive repairs. Our ...
A public health emergency such as an influenza pandemic will lead to shortages of mechanical ventilators, critical care beds, and other potentially life saving treatments. This will raise difficult...Full Text Available
We investigated high-resolution mental imagery and mental rotation, while the participants received caloric vestibular stimulation. High-resolution visual mental imagery tasks have been shown...Full Text Available
Invasive species are increasingly becoming a policy priority. This has spurred researchers and managers to try to estimate the risk of invasion. Conceptually, invasions are dependent both on the receiving...Full Text Available
The advanced technologies of Ka-Band systems such as high gain spot .... sometimes used based on link requirements for a specific application. .... received at NASA LeRC from a Ku-band satellite and retransmitted to the USAT at Ka-Band. .... and to the Office of Management and Budget, Paperwork Reduction Project ...
BackgroundDespite the grave consequences of sexual violence, and it's persistence both within and outside marriages, this subject has received relatively little attention from researchers,...Full Text Available
Background:Children suffering from beta-thalassemia major require repeated blood transfusions which may be associated with dangers like iron overload and contraction of...Full Text Available
Separate groups of rats received 500 trials of lever-press training under autoshaping (food delivery followed 10-second lever presentations, or occurred immediately following a response); operant conditioning...Full Text Available
A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.
ObjectivesTo investigate the effect of group cognitive behavioural therapy (CBT) for fatigue self-management, compared with groups receiving fatigue information alone, on fatigue...Full Text Available
In the case where sources and receivers are not distributed on a 2-D plane, seismic tomography inversion was studied. In tomography experiments, the existing wells are generally used. In such case, sources and receivers are frequently not distributed on a 2-D plane. The 2.5-D analysis method including 2-D structure and 3-D ray-tracing was thus developed. This method is featured by less memory necessary for ray-tracing calculation, and the same algorithm for velocity determination as 2-D analysis method. In previous methods, since analysis is generally carried out by projecting sources and receivers on a certain assumed 2-D plane, it can derive correct results in the case of constant velocity and straight ray, however, in the other case, it derives incorrect results. Application of 3-D tomography requires a large amount of memory, and falls into poor convergence because of various parameters. The 2.5-D analysis method can ...
In the context of the research project, the physical basis of the direct decoupling of highly concentrated solar radiation in materials without the detour via absorbing heat exchanger walls was examined. Also, the first chemical processes suitable for the effective long-term storage of solar energy were analysed, relevant experiments were carried out and the necessary receiver techniques for high temperature applications were provided. The principle of direct coupling was examined on fluidized beds on the one hand and on cavity receivers, on the other hand. The contribution shows the results achieved in detail. It is recorded that first processes for storing solar energy in chemical reactions were able to be examined. Alkaline earth hydroxides accommodated in ceramic honeycomb structures seem to be possible as stores for medium temperature ranges around 500deg C. Investigations on receiver structure materials are also ...
This report presents results from the soil inorganic analysis of the 44th set of environmental quality assessment samples, of the quality assessment program, that were received on or before June 3, 1996. The samples were analyzed for RCRA metals.
Using plasma glutathione S-transferase measurements hepatocellular integrity was assessed in groups of hyperthyroid and hypothyroid patients before and after treatment. Ten of 14 hyperthyroid patients...Full Text Available
Forty-four patients with histologically proven Hodgkin's disease underwent initial treatment with extended-field radiation therapy. Nineteen of these patients also received combination chemotherapy....Full Text Available
A scientific breakthrough at Queen's University's Sudbury Neutrino Observatory has received major international recognition. The journal Science ranked the discovery that cracked the "neutrino problem" second, in the journal's top 10 scientific achievements of 2002 (1/2 page).
The morphogenesis of pulmonary edema and bronchiolar injury induced by the toxic furan, 4-ipomeanol, was studied by combined light and transmission electron microscopy. Weanling male CD-1 mice received...Full Text Available
A substantial proportion of lymph node-negative patients who receive adjuvant chemotherapy do not derive any benefit from this aggressive and potentially toxic treatment. However, standard histopathological...Full Text Available
A prospective cohort study was undertaken in two commercial California dairies. The treatment group, 246 cows, received three doses of a whole cell bacterin of J5 Escherichia coli (mutant of E. coli...Full Text Available
Natural resources in general and plant materials in particular are receiving more attention due to their safety as pharmaceutical excipients. Present work assessed the potential of a natural polysaccharide,...Full Text Available
A prototype trumpet type nonimaging secondary concentrator was designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW{sub e} dish-Stirling system. A set of operational tests was carried out with a high temperature heat pipe receiver and gas-gap calorimeter. These tests have successfully alleviated any operational concerns about the effectiveness of active water cooling for such devices. The authors obtained over two full days of testing with the cavity receiver operating at its design temperature of 660 C while the trumpet throat temperature remained {approx_equal} or less than 100 C. In addition, these tests have shown that the thermal isolation of the trumpet from the hot receiver is very effective. Highly variable insolation, instabilities in the temperature controller on the calorimeter, and a poor match between the optical quality of the primary and the design of the trumpet have made detailed ...
The Poison Control Centre at Toronto's Hospital for Sick Children received over 25,000 telephone inquiries in 1981. Those at greatest risk of accidental poisoning are children under age five. Education...Full Text Available
BackgroundThe aim of the study was to compare the prevalence and types of HIV-related oral lesions between children and adult Tanzanian patients on HAART with those not on HAART...Full Text Available
With respect to concept of resolution in seismic exploration using the reflection method, detailed considerations were given on processes of forming the resolution as a result of arranging observation points at vibration transmitting and receiving points. In the discussion, numerical experiments were carried out, in which the scattering stacking process is applied in a model having one scatterer existing in homogeneous media. The experiments investigated an imaging formation process of the scatterer when arrangement of the vibration transmitting and receiving points were changed from a coarse condition to a dense condition while the number of transmitting and receiving points is being increased. Resolution is created if waveforms having finite frequencies are used as input, and the imaging is performed by utilizing the limited number of vibration receiving and transmitting points. If the concept of ...
Profile of aid statistics to Pakistan. Shows the amount of aid received, the major donors and the form in which the majority of the aid is given. Especially useful when compared to the aid profile of similar countries. Shows that ODA accounts for about 1.5% of Pakistani GDP and that it is distributed over various sectors.
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judges (AU), the Directors` Decisions (DD), and the Decisions on Petitions for Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission, the Atomic Safety and Licensing Appeal Boards, the Atomic Safety and Licensing Boards, the Administrative Law Judge, the Directors' Decisions, and the Denials of Petitions for Rulemaking.
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), the Directors' Decisions (DD), and the Denials of Petitions for Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission (CLl), the Atomic Safety and Licensing Appeal Boards (ALAB), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judge (ALJ), The Directors' Decisions (DD), and the Denials of Petitions For Rulemaking (DPRM).
This report includes the issuances received during the specified period from the Commission (CLI), the Atomic Safety and Licensing Boards (LBP), the Administrative Law Judges (ALJ), the Directors Decisions (DD), and the Decisions on Petitions for Rulemaking (DPRM).
The 2010 leave year ends with pay period 201101 (ending January 1, 2011). ... The agencies must also ensure that FERS employees receive the appropriate Agency Automatic (1%) ... Voluntary Leave Transfer Program/Advance Sick Leave ...
The Regulatory Agenda is a semiannual compilation of all rules on which the NRC has recently completed action, or has proposed action, or is considering action, and of all petitions for rulemaking that the NRC has received that are pending disposition.
BackgroundSome breast cancer patients receiving anti-angiogenic treatment show increased metastases, possibly as a result of induced hypoxia. The effect of hypoxia on tumor cell...Full Text Available
Many patients who undergo hematopoietic cell transplantation (HCT) present with anemia and have received red blood cell transfusions before HCT. As a result, iron overload is frequent and appears...Full Text Available
Exosomes are small membrane vesicles secreted from various types of cells. Tumor-derived exosomes contain MHC class I molecules and tumor-specific antigens, receiving attention as a potential cancer...Full Text Available
BackgroundLittle is known about the acceptability of internet and telephone treatments, or what factors might influence patient interest in receiving treatments via...Full Text Available
The University of Cincinnati (UC) has been active in the National Library of Medicine's Integrated Advanced Information Management Systems (IAIMS) program since IAIMS' inception in 1984. UC received...Full Text Available
Sensory experience plays a crucial role in regulating neuronal shape and in developing synaptic contacts during brain formation. These features are required for a neuron to receive, integrate, and transmit...Full Text Available
The development of azole resistance in Candida albicans is most problematic in patients with AIDS who receive long courses of drug for therapy or prevention of oral candidiasis. Recently,...Full Text Available
BackgroundThe prevalence of tobacco use among individuals with mental illness remains a serious public health concern. Tobacco control has received little attention in community...Full Text Available
Objectives:Despite its impact on health policy, the relationship between geographical proximity and health care seeking has received scant attention in the medical literature. This...Full Text Available
Purpose:The oral chemotherapy cycle management program (CMP) provides clinical management support to patients receiving certain oral chemotherapies. The CMP includes a dose-monitoring...Full Text Available
Oct 28, 2009 ... Note: FERS employees become eligible for disability retirement after 18 ... Can I use advanced sick leave while I am on the Voluntary Leave ...
Rapid place encoding by hippocampal neurons, as reflected by place-related firing, has been intensely studied, whereas the substrates that translate hippocampal place codes into behavior have received...Full Text Available
AIMS: To examine the frequency of intraocular metastases in patients who had died of cancer, in an eye bank and necropsy population sample. METHODS: The first group included 302 cancer cases received...Full Text Available
Electronic and structural properties of antiphase boundaries in group III-V semiconductor compounds have been receiving increased attention due to the potential to integration of optically-active III-V...Full Text Available
Patients treated with bleomycin are at risk of developing the acute adult respiratory distress syndrome post-operatively. In a prospective study of 12 patients who had received bleomycin preoperatively...Full Text Available
BackgroundAlthough ivermectin is distributed free of charge through the African Programme for Onchocerciasis Control (APOC), not all eligible individuals within communities receive...Full Text Available
Officers receive service-specific education and undergo experiences within their components that provide the expert knowledge that enables them to operate in their respective military departments. Given the Department of Defense (DoD) emphasis on service ...
Feb 28, 2001 ... Dr. Ellen Ochoa was born on May 10, 1958 in Los Angeles, CA, but considers Las Mesa, California to be her hometown. She received her ...
In a cross-over study, participants (n=59) were randomly assigned to receive either 100 kcal packs or standard size packages of snacks for 1-week. After a minimum of a 1-week washout period,...Full Text Available
Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available
Simple correlations and corresponding nomographs are presented, which express the maximum useful heat received from salt-gradient solar ponds throughout the year or during a specified season of the year, and the corresponding optimum depth of the nonconvective zone in terms of the thickness of the upper convective zone and the temperature under which the maximum useful heat is received. The correlations are valid for the Athens (Greece) area or for regions with a similar climate, because solar radiation and ambient temperature values for Athens have been employed, obtained by a statistical process of hourly measurements over a period of about 20 years. For other climates, it is easy to develop similar correlations using the same methodology, Development of the proposed correlations is based on a method, which simulates the transient operation of the salt-gradient pond using finite-differences, and calculates the useful heat ...
As part of its long-term control plan for combined sewer overflow (CSO) abatement, the city of Buffalo, New York, maintained a network of Hydrolab Datasondes (Hydrolab-Hach Company, Loveland, Colorado) to assess receiving water-quality effects by continuously logging dissolved oxygen, pH, temperature, conductivity, and turbidity. Although the effect of individual CSOs could be visualized, turbidity levels entering the Buffalo River from the upper watershed often were greater than from CSO discharges. Turbidity data showed that the Buffalo River was a net-sediment sink. Low dissolved oxygen levels were observed in the summer during dry weather, baseflow, and watershed-wide storms and CSO events. Some CSOs did not produce dissolved oxygen sags in the receiving waters, but others did. This information, together with the sampling done for organic and inorganic contaminants, can aid the decisionmaking process when prioritizing outfalls for abatement ...
Plasma triglyceride turnover was measured during steady-state conditions in 22 postoperative patients. Nine had received nutritional support with an enteral regimen, seven had received an equivalent regimen as continuous parenteral nutrition, and six received the same parenteral regimen as a cyclical infusion. After 5 days of nutritional support, each patient received an intravenous bolus of tritiated glycerol. Plasma radiolabeled triglyceride content was measured during the subsequent 24 hours. The data were analyzed by means of a simple deterministic model of plasma triglyceride kinetics and compared with the results obtained by stochastic analysis. The rates of hepatic triglyceride secretion obtained by deterministic analysis were higher than those obtained by the stochastic approach. However, the mode of delivery of the nutritional regimen did not affect the rate of hepatic triglyceride secretion ...
You receive an annuity if eligible -- requires 18 months service for FERS; and 60 ... You may use up to 104 hours of your accrued sick leave to care for sick family ...
Six children who received craniospinal irradiation for medulloblastoma when they were under 10 years of age developed learning disabilities. Four exhibited associated temporal lobe calcification on...Full Text Available
Carcinoma in situ in the contralateral testis was diagnosed in 27 of 500 patients (5.4%) with unilateral testicular germ cell cancer. Eight of the 27 patients received intensive chemotherapy for spread...Full Text Available
Differential scanning calorimetric (DSC) studies of the glassy states of as-received and hydrated lysozyme, hemoglobin, and myoglobin powders, with water contents of < or = 0.25, < or...Full Text Available
A 74-year-old male patient receiving ventilatory support due to aspiration pneumonia developed bilateral pneumothorax, pneumopericardium, pneumomediastinum, pneumo-retroperitoneum, and subcutaneous...Full Text Available
IntroductionThe goal of this study was to identify serum markers that are modulated by treatment with golimumab with or without methotrexate (MTX) and are associated with clinical...Full Text Available
The increased risk of thrombosis in patients with active cancer has multiple causes. Acute thrombosis of the aorta is an exceedingly rare but potentially devastating complication in patients with cancer...Full Text Available
BackgroundThe receiver operating characteristic (ROC) curve is a fundamental tool to assess the discriminant performance for not only a single marker but also a score function combining...Full Text Available
...position to receive material. (2) Self-loading haulage equipment used as a loading machine. In working places in which self-loading haulage equipment is operated to load material, the areas which...
Purpose: Patients with mycosis fungoides [cutaneous T-cell lymphoma (CTCL)] may benefit from adjuvant therapy after completing total skin electron beam therapy (TSEBT). We report the results for (T1(T2)) CTCL patients treated with adjuvant oral psoralen plus ultraviolet light (PUVA) with respect to overall survival (OS), disease-free survival (DFS), salvage of recurrence, and toxicity. Methods and Materials: Between 1974 and 1993, TSEBT was administered to a total of 213 patients with CTCL. Records were reviewed retrospectively, and a total of 114 patients were identified as having T1 or T2 disease. Radiotherapy was provided via a 6-MeV linac to a total of 36 Gy, 1 Gy/day, 4 days/week, for 9 weeks. Beginning in 1988, patients were offered adjuvant PUVA within 2 months of completing TSEBT. This was started at 0.5-2 J/m"2, 1-2 treatments/week, with a taper over 3-6 months. Therapy then continued once per month. There were 39 T1 and 75 T2 patients. Six T1 (15%) and eight T2 (11%) patients ...
Two avowable quantum communication schemes are proposed. One is an avowable teleportation protocol based on the quantum cryptography. In this protocol one teleports a set of one-particle states based on the availability of an honest arbitrator, the keys and the Einstein-Podolsky-Rosen pairs shared by the communication parties and the arbitrator. The key point is that the fact of the teleportation can neither be disavowed by the sender nor be denied by the receiver. Another is an avowable quantum secure direct communication scheme. A one-way Hash function chosen by the communication parties helps the receiver to validate the truth of the information and to avoid disavowing for the sender.
Two avowable quantum communication schemes are proposed. One is an avowable teleportation protocol based on the quantum cryptography. In this protocol one teleports a set of one-particle states based on the availability of an honest arbitrator, the keys and the Einstein Podolsky Rosen pairs shared by the communication parties and the arbitrator. The key point is that the fact of the teleportation can neither be disavowed by the sender nor be denied by the receiver. Another is an avowable quantum secure direct communication scheme. A one-way Hash function chosen by the communication parties helps the receiver to validate the truth of the information and to avoid disavowing for the sender.
A solar energy receiver is described including a separable endless wall formed of a ceramic material having defined therein a cavity of a substantially cylindrical configuration for entrapping solar flux, and an acceptance aperture adapted to admit to the cavity a concentrated beam of solar energy, said wall being characterized by at least a pair of contiguously related segments separated by lines of cleavage intercepting said aperture, at least one of the segments being supported for pivotal displacement, and a thermal responsive actuator adapted to respond to excessive temperatures within the cavity for initiating pivotal displacement of said one segment, whereby thermal flux is permitted to escape from the cavity.
A simple theory for predicting the convective energy loss from side-facing cavity receivers in windless environments has been developed. The approach used is to determine the velocity distribution of the incoming air in the aperture plane (and thereby the rate of mass entrainment); and then to estimate the bulk temperature of the heated emerging air. The convective loss is then calculated from an energy balance. To illustrate this theory, numerical results applicable to the 2.15 meter cubic cavity being tested in the laboratory are provided.
An electronic computer circuit is described for producing an output voltage proportional to the product or quotient of tbe voltages of a pair of input signals. ln essence, the disclosed invention provides a computer having two channels adapted to receive separate input signals and each having amplifiers with like fixed amplification factors and like negatlve feedback amplifiers. One of the channels receives a constant signal for comparison purposes, whereby a difference signal is produced to control the amplification factors of the variable feedback amplifiers. The output of the other channel is thereby proportional to the product or quotient of input signals depending upon the relation of input to fixed signals in the first mentioned channel.
RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.
Convective losses arising from buoyancy driven flow were calculated for a two-dimensional model simulating a solar cavity receiver. The TEMPEST code, capable of fully three-dimensional coupled thermal-hydraulic transient calculations, was used for the simulation. Predicted velocity and temperature results for a 2.59 m deep by 2.88 m high rectangular cavity with an aperture opening of 1.72 m were used to determine convective losses for prescribed interior wall temperatures and cavity orientation. Velocity vector and temperature isotherm plots were used to analyze flow characteristics.
We propose a simple and accurate method to evaluate the outage probability at the output of arbitrarily fading L-branch diversity combining receiver. The method is based on the saddlepoint approximation, which only requires the knowledge of the moment generating functions of the signal-to-noise ratio at the output of each diversity branch. In addition, we show that the obtained results reduce to closed-form expressions in many particular cases of practical interest. Numerical results illustrate a very high accuracy of the proposed method for practical outage values and for a large mixture of fading and system parameters.
The conceptual design, parametric analysis, cost and performance analysis, and commercial assessment of a 100-MWe line-focus solar central receiver power plant are reported. This volume contains the appendices: (a) methods of determination of molten salt heat-transfer coefficients and tube-wall temperatures, (b) inputs for STEAEC programs, (c) description of system analysis computer program, (d) receiver analysis program, and (e) heliostat production plan and design methodology. (WHK)
Information from the CHIS Board and Personnel Division:A new contract to manage our health insurance has been signed with AUSTRIA and it will come into force on 1 January 2000.The changeover to the new contract will not affect those covered by thescheme since there will be no change in the list of services reimbursed or in the reimbursement procedure.However, you are requested (as far as possible) to submit separate claims fortreatment (not bills) received before 1 January 2000 as opposed to treatment received after 1 January 2000. This will help AUSTRIA with its accounting.
CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral ...
CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is superior to that receiving oral contrast ...
This report is the user's manual of seismic system reliability analysis code SECOM2 (Seismic Core Melt Frequency Evaluation Code Ver.2) developed at the Japan Atomic Energy Research Institute for systems reliability analysis, which is one of the tasks of seismic probabilistic safety assessment (PSA) of nuclear power plants (NPPs). The SECOM2 code has many functions such as: Calculation of component failure probabilities based on the response factor method, Extraction of minimal cut sets (MCSs), Calculation of conditional system failure probabilities for given seismic motion levels at the site of an NPP, Calculation of accident sequence frequencies and the core damage frequency (CDF) with use of the seismic hazard curve, Importance analysis using various indicators, Uncertainty analysis, Calculation of the CDF taking into account the effect of the correlations of responses and capacities of components, and Efficient sensitivity analysis by ...
Fourteen irradiated Fast Flux Test Facility (FFTF) fuel pins were subjected to representative overpower transients in six flowing sodium loop experiments conducted in the TREAT reactor. The transient tests were extended to substantial overpower levels well beyond protected levels, with some tests intentionally run to failure to identify failure thresholds and characteristics. Test variables included transient ramp rate (5, 50, and 100 cents/s) and burnup (2 to 58 MWd/kg). Performance limits and failure characteristics were identified, and cladding strain and fuel melting data were obtained for development and verification of transient analysis codes. The test results demonstrated that FFTF Reference fuel pins are capable of surviving overpower levels well beyond the FFTF secondary Plant Protection System (PPS) trip limit of 1.25 times normal rated power. Based on analytical evaluations to interpolate and extrapolate test ...
The use of deuterium-tritium fuel in the Compact Ignition Tokamak will require applying remote handling technology for ex-vessel maintenance and replacement of machine components. Highly activated and contaminated components of the fusion devices auxiliary systems, such as diagnostics and RF heating, must be replaced using remotely operated maintenance equipment in the test cell. In-vessel remote maintenance included replacement of divertor and first wall hardware, faraday shields, and for an in-vessel inspection system. Provision for remote replacement of a vacuum vessel sector, toroidal field coil or poloidal field ring coil was not included in the project baseline. As a result of recent coil failures experienced at a number of facilities, the CIT project decided to reconsider the question of remote recovery from a coil failure and, in January of 1990, initiated a coil replacement study. This study focused on the technical requirements and ...
On February 20th 1998 Auckland, the biggest city of New Zealand, was nearly paralyzed by an extended power failure. On this day the last of four cables supplying the central business district failed and caused a five weeks lasting blackout. This failure has caused costs of 128.3 Mio NZ Dollar for the affected utility Mercury Energy Ltd. The official ministerial inquiry was published on July 21st 1998 and reproaches the utility in an unusual clear manner. (orig.) [Deutsch] Am 20. Februar 1998 wurde Auckland, die groesste Stadt Neuseelands, von einer folgenschweren Unterbrechung der Stromversorgung nahezu lahmgelegt. An diesem Tag fiel das letzte von vier 110-kV-Kabeln zur Versorgung des Innenstadtbereiches aus und verursachte damit einen 5 Wochen dauernden Stromausfall. Diese Versorgungsunterbrechung hat bisher Kosten in Hoehe von 128,3 Mio NZ Dollar (rd. 115,5 Mio DM) fuer den oertlichen Stromversorger Mercury Energy Limited verursacht. Der am ...
This paper demonstrates that a commercial-scale facility for encapsulating krypton-85 in zeolite-5A or glass at a 2000 MTHM per year nuclear fuel reprocessing plant can be designed to contain fragments and the 340 to 850 kCi krypton-85 inventory from an assumed catastrophic failure of the high pressure vessel. The vessel failure was assumed as a worst case and was not based on a detailed design evaluation or operating experience. The process design is based on existing commercial hot isostatic pressing technology operated at up to 40 times the scale required for krypton encapsulation. From the calculated process gas inventory in the pressure vessel and vessel design, the maximum explosive energy of 8.4 kg TNT and resulting vessel plug and fragment velocities were calculated. The facility Containment Cell housing the high pressure vessel was designed to contain the gases, fragments, and the shock wave energy calculated for a hypothetical vessel ...
The leakage behavior of containments beyond design conditions and knowledge of failure modes is required for evaluation of mitigation strategies for severe accidents, risk studies, emergency preparedness planning, and siting. These studies are directed towards assessing the risk and consequences of severe accidents. An accident sequence analysis conducted on a Boiling Water Reactor (BWR), Mark I (MK I), indicated very high temperatures in the dry-well region, which is the location of the majority of electrical penetration assemblies. Because of the high temperatures, it was postulated in the ORNL study that the sealants would fail and all the electrical penetration assemblies would leak before structural failure would occur. Since other containments had similar electrical penetration assemblies, it was concluded that all containments would experience the same type of failure. The results of this study, however, show that ...
Westinghouse is currently conducting the pre-application licensing of the International Reactor Innovative and Secure (IRIS). One of the key aspects of the IRIS design is its safety-by-designTM philosophy and within this framework the PRA is being used as an integral part of the design process. The most ambitious risk-related goal for IRIS is to reduce the Emergency Planning Zone (EPZ) to within the exclusion area by demonstrating that the off-site doses are consistent with the US Protective Action Guidelines (PAGs) for initiation of emergency response so that the required protective actions would be limited to the exclusion area. As a first step, a model has been developed to provide a first order approximation of the Large Early Release Frequency (LERF) as a surrogate predictor of the off-site doses. A key-aspect of the LERF model development is the characterization of the possible paths of release. Four main categories have been historically pointed out: (1) Core Damage (CD ) ...
The purpose of this work was to investigate the role of chromium on hydrogen embrittlement of Ni-Cr-Fe alloys and thus to develop a better understanding of the low-temperature stress corrosion cracking (SCC) phenomenon. The effect of chromium on hydrogen embrittlement was examined using tensile tests followed by material evaluation via scanning electron microscopy (SEM) and light optical microscopy. Four alloys were prepared with chromium contents ranging from 6 to 35 wt pct. In the uncharged condition, ductility, as measured by the percent elongation or reduction in area, increased as the alloy chromium content increased. Hydrogen appeared to have only minor effects on the mechanical properties of the low-chromium alloys. The addition of hydrogen had a marked effect on the ductility of the higher-chromium alloys. In the 26 pct chromium alloy, the elongation to failure was reduced from 53 to 14 pct, with a change in fracture mode from mixed ductile dimple and ...
There are two kinds of uncertainties in safety assessment of engineering structures. One is of the nature of randomness, and the other fuzziness. Fuzzy uncertainties exist in defining certain structural performances, conditions, parameters, and their interrelationships. The theory of fuzzy sets should be employed to cope with the fuzzy uncertainties. In this paper, a general definition for structural failure considering the fuzzy uncertainties is introduced firstly. Failure of the structure is modelled by a fuzzy event, and described by the membership function. The limit state surface is then replaced by a fuzzy limit state zone, in which every point represents a state belonging to the failure with a certain degree of membership. Then a fuzzy optimization problem for solving the reliability index is formulated. In classical structural reliability theory, the reliability index is defined by the minimum distance from the ...
We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, we describe new, biased voltage contrast imaging techniques and provide examples of ...
The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant ...
The downstream failure of cable during winding, insulating, coil winding, and coil assembly is a significant issue in magnet production. The impact of these failures are costly both financially, and from the time to recover from this downstream failure. The current approach to cabling has been to visually inspect the cable for any gross defects during cabling. To date this has been effective in finding small defects such as crossovers for example, which drastically reduce the mechanical integrity of the strand, and thus the cable itself. But because of the large volume of cable which will be manufactured an automated flaw detection system which can inspect the cable and detect these type of defects will be needed. We have recently done an on-line experiment using an Eddy current system, and specialized Eddy current probes to inspect cable during manufacturing. We will present the results of our inspection demonstrating ...
The Fast Flux Test Facility (FFTF) features a three-loop, sodium-cooled 400 MWt mixed oxide fueled reactor designed for the irradiation testing of fuels and materials for use in liquid metal cooled fast reactors. To establish the ultimate capability of a particular fuel design and thereby generate information that will lead to improvements, many of the fuel irradiations are continued until a loss of cladding integrity (failure) occurs. When the cladding fails, fission gas escapes from the fuel pin and enters the reactor cover gas system. If the cladding failure permits the primary sodium to come in contact with the fuel, recoil fission products can enter the sodium. The presence of recoil fission products in the sodium can be detected by monitoring for the presence of delayed neutrons in the coolant. It is the present philosophy to not operate FFTF when a failure has occurred that permits fission fragments to enter the ...
The Reliability and Availability Data System (RADS) is a database and analysis code, developed by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Nuclear Regulatory Commission (USNRC). The code is designed to estimate industry and plant-specific reliability and availability parameters for selected components in risk-important systems and initiating events for use in risk-informed applications. The RADS tool contains data and information based on actual operating experience from U.S. commercial nuclear power plants. The data contained in RADS is kept up-to-date by loading the most current quarter's Equipment Performance and Information Exchange (EPIX) data and by yearly lods of initiating event data from licensee event reports (LERS). The reliability parameters estimated by RADS are (1) probability of failure on demand, (2) failure rate during operation (used to calculate failure to ...
For a reliable design against fatigue failure of high-temperature components of different types of the heat resistant material Alloy 800, verified parameters of the low-cycle fatigue (LCF) behaviour are required. These parameters were obtained by a scatterband evaluation of the results of low-cycle fatigue tests, using a computerized data bank which includes all available actual data sets. The results of the evaluation are presented as mean fatigue curves with the upper and lower boundary limits of the scatterbands. For the type Alloy 800 in the recrystallization annealed condition, the results cover a temperature range from 20 to 750deg C; for the solution annealed types they cover a temperature range from 20 to 950deg C. Specimens tested in HTR helium at high temperatures had longer lives than specimens tested in air. This effect was represented quantitatively by the ratio of the total strain ranges from tests in HTR helium and air as a function of test ...
One of the main applications of PSA studies is related to identification of the major key issues related to plant safety. In standard PSA one assumes a constant value for component failure rates by considering that the component doesn't experience any degradation that could affect its performance. Used in this manner, standard PSA tools do not adequately address important ageing issues, and this fact could have a significant impact on the conclusions drawn from PSA studies and applications, in conditions of operation of ageing plants. To obtain realistic results, it is necessary to consider in the PSA model the ageing effects, and to do that it is necessary to take into consideration the change in component failure rate as a function of component age. In case of ageing phenomena, this dependence causes the failure rate of a component (or a set of components) to increase in time as the component age increase. The paper ...
Background 2009 pandemic influenza A(H1N1) has led to a global increase in severe respiratory illness. Little is known about kidney outcomes and dialytic requirements in critically ill patients infected with pandemic H1N1. Study Design Prospective observational study. Setting & Participants 50 patients with pandemic H1N1 admitted to any of 7 intensive care units in Manitoba, Canada, were prospectively followed. Outcome & Measurements Outcomes were kidney injury and kidney failure defined using RIFLE (risk, injury, failure, loss, end-stage disease) criteria or need for dialysis therapy. Results The pandemic H1N1 group was composed of 50 critically ill patients with pandemic H1N1 with severe respiratory syndrome (47 confirmed cases, 3 probable). Kidney injury, kidney failure, a...
Some considerations regarding ice load in risk-based dam safety analysis are presented for small concrete dams. The most significant physical mechanisms leading to ice thrust on dams (such as thermal expansion and water level fluctuations) are outlined. Published literature on dam ice loads to examine ice load magnitude-return period relationships, sliding and overstressing failure mechanisms and structural performance criteria to resist ice loads, are also reviewed. Related loading combinations for structural safety evaluations were determined regarding the issue of simultaneity of ice loads with other events such as earthquakes. Parametric analyses were conducted on a small gravity dam section, 3m high, and a taller dam, 17.9 m high, to demonstrate the ultimate ice load carrying capability as a function of dam geometry and shear and tensile strengths of construction joints. Since the failure mechanism of a dam subjected to excessive ice loads ...
The condition of spent nuclear fuel (SNF) in wet storage at ten Soviet-designed research reactors has been assessed in the light of international experience in order to identify any associated safety issues. These reactors use Al-clad UO2-Al or U-Al alloy dispersion fuels of ?20% enrichment that were fabricated in Russia; the reactors have been in operation since 1955-70. Although originally sent for reprocessing, much of the SNF generated over the last 25-30 years has been stored in fuel storage pools (FSPs) of variable water quality. The external condition of wet-stored SNF assemblies from the reactors surveyed varied from significant failure due to galvanic corrosion that was driven by poor water quality, through gradual pitting caused by slightly impure water, to a stable condition of no observable change in the oxidized Al alloy surface of the irradiated fuel. SNF stability in wet storage seems to depend on three factors: Al being the sole metal in the FSP (to ...
Liquid-liquid wetting failure is investigated in a two-dimensional Couette system with two immiscible fluids of arbitrary viscosity. The problem is solved exactly using a sharp interface treatment of hydrodynamics (lubrication theory) as a function of the capillary number, viscous ratio and separation of scale, i.e. slip length versus macroscopic scale of the system. The existence of critical velocities, above which no stationary solutions are found, is analyzed in detail in terms of the relevant parameters of the system. Comparisons with existing analysis for other geometries are also carried out. A numerical method of analysis is also presented, based on diffuse interface models obtained from multiphase extensions of the lattice Boltzmann equation (LBE). Sharp interface and diffuse interface models are quantitatively compared face to face indicating the correct limit of applicability of the diffuse interface models.
Polymer insulating materials used in radioactive environments are subjected to a risk of surface degradation caused by tracking. The tracking behavior becomes more complex with the presence of magnetic field. This paper presents investigation of tracking failure of gamma-ray irradiated polybutylene naphthalate (PBN) and polybutylene terephthalate (PBT) under magnetic field. The samples were irradiated in air up to 100 kGy and then up to 1000 kGy with dose rate of 10 kGy/h by using a 60Co gamma-source. Magnetic field Formula Not Shown with flux density of 250 mT was assembled perpendicularly to electric field Formula Not Shown , which gave rise to relative angle between Formula Not Shown and surface normal vector Formula Not Shown of 0degree, 90degree and 180degree, respectively. The experi...
This paper is concerned with the fracture analysis of thin cylindrical shells subject to secondary bending stresses with some degree of elastic follow-up. A P.Y.F.M. failure assessment route is utilised for an initial investigation. Results are presented graphically and indicate the differences obtained by considering the stresses as primary or secondary in nature. The Jsup(*) contour integral is computed from the results of a non-linear finite element analysis of a thermally loaded cracked cylinder. Comparison is made between Jsup(*) and the P.Y.F.M. failure criteria demonstrating the degree of conservatism in the latter. It is observed that LEFM may be appropriate for moderate load levels but that the elastic follow-up of the structure causes enhancement of Jsup(*) for higher loads, at which stage LEFM becomes non-conservative. (orig.).
A geological and geotechnical framework was provided in order to facilitate understanding of the damage to structures resulting from soil conditions during the earthquake of January 17, 1995 at Hyogo-ken Nanbu (Kobe), Japan. Special attention was paid to the large scale failures of the quay walls in the port of Kobe, resulting from liquefaction. The performance of structures in improved and unimproved ground were compared. It was observed that locations with some previous site improvements through densification behaved satisfactorily, despite unanticipated high levels of ground motion. Soil-structure interaction problems, such as pile foundations, bridge piers, lifelines, and an underground subway station were also described. Reference was made to the significance of these failures for the seismic design in the Fraser Delta in British Columbia in view of the area`s proneness to liquefaction during a major earthquake. 31 refs., 5 tabs., 45 figs.
RIFLE criteria have been used to determine the incidence of acute kidney dysfunction (AKD) after orthotopic liver transplantation (OLT). However, no studies have focused on the incidence of AKD after OLT in patients with normal pre-OLT kidney functions. Using the RIFLE criteria, we determined the incidence and risk factors for AKD after OLT in patients with normal pre-OLT kidney function. We retrospectively analyzed the records of 112 patients who underwent OLT from January 2000 to February 2009 with normal prior kidney function. We investigated three levels of renal dysfunction outlined in the RIFLE criteria: risk (R); injury (I); and failure (F). Preoperative, intraoperative, and postoperative variables were collected. AKD occurred in 64 (57%) OLTs with risk, injury, and failure frequenc...
Proper use of quality assurance will provide the basis for an effective management control system for nuclear waste management programs. Control is essential for achieving successful programs free from costly losses and failures and for assuring the public and regulators that the environment and health and safety are being protected. The essence of quality assurance is the conscientious use of planned and systematic actions, based on selecting and applying appropriate requirements from an established quality assurance standard. Developing a quality assurance program consists of using knowledge of the technical and managerial aspects of a project to identify and evaluate risks of loss and failure and then to select appropriate quality assurance requirements that will minimize the risks. Those requirements are integrated into the project planning documents and are carried out as specific actions during the life of the project.
Objectives: Intra-operative cisplatin-based intra-peritoneal chemotherapy (IPC) may alter renal function in patients with advanced ovarian cancer. The aim of this study was to describe postoperative alteration of renal function after cisplatin-based IPC and to identify risk factors for moderate to severe acute renal failure. Study design: This prospective observational study was carried out on 77 consecutive patients who underwent cisplatin-based IPC procedures, with (n=23) or without (n=54) intra-peritoneal epinephrine, for advanced ovarian cancer. Postoperative renal function was assessed using serial serum creatinine measurements and was based on serum creatinine changes from pre-operative values, according to the risk, injury, failure, loss, end-stage kidney disease (RIFLE) classificat...
Abstract Introduction. Spinal cord stimulation (SCS) is an effective procedure for the treatment of neuropathic extremity pain, with success rates approaching 70%. However, mechanical failures, including breakage and migration, can significantly limit the long-term effectiveness of SCS. A systematic analysis of surgical techniques was undertaken by a consensus group, coupled with extensive in vivo and in vitro biomechanical testing of system components. Methods. A computer model based on morphometric data was used to predict movement in a standard SCS system between an anchored lead and pulse generator placed in various locations. These displacements were then used to determine a realistic range of forces exerted on components of the SCS system. Laboratory fixtures were constructed to subj...
This report gives a brief introduction to the project `Probabilistic Design Tool for Wind Turbines` - PRODETO - which was carried out during the years 1996-98 with partial funding from the European Commission under the Non-Nuclear Energy Programme JOULE III. The report gives an overview of the objectives and motivation for the project, and the methodology used. In this context, an example of reliability-based wind turbine design against fatigue failure is outlined with emphasis on the various important steps herein, which include probabilistic load and resistance modelling, calculation of failure probability, and calibration of partial safety factors for use with a deterministic design code format. The results of the project are presented with emphasis on a developed computer program and its capabilities, and the various elements of an executed case study are outlined. A list of project reports concludes the report. (au)
Background: Intestinal failure (IF) is the dependence upon parenteral nutrition to maintain minimal energy requirements for growth and development. It may occur secondary to a loss of bowel length, disorders of motility, or both. Short bowel syndrome (SBS) is a malabsorptive state resulting from surgical resection, congenital defect, or diseases associated with loss of absorptive surface area. A particularly vexing problem is associated with whole bowel and/or segmental intestinal dysmotility. Motility disorders within the context of SBS and IF may relate to rapid intestinal transit secondary to loss of intestinal length, dysmotility associated with loss or poor antegrade peristalsis, or gastroparesis. Therapy may be classified into medical (prokinetic and antidiarrheal agents) and surgica...
The exposure and subsequent undermining of pier/abutment foundations through the scouring action of a flood can result in the structural failure of a bridge. Bridge scour is one of the leading causes of bridge failure. Bridges subject to periods of flood/high flow require monitoring during those times in order to protect the traveling public. In this study, an innovative scour monitoring system using button-like fiber Bragg grating (FBG) sensors was developed and applied successfully in the field during the Aere typhoon period in 2004. The in situ FBG scour monitoring system has been demonstrated to be robust and reliable for real-time scour-depth measurements, and to be valid for indicating depositional depth at the Dadu Bridge. The field results show that this system can function well and survive a typhoon flood.
To predict the fatigue life of fiber reinforced composites, fatigue process of CFRP laminates of [0 /90 ]{sub s} is investigated and the influence of damages occurring at fiber, matrix and fiber/matrix interface on the various critical strengths and the relationship between residual critical strength and failure are discussed. As a result, it was shown that fatigue strength (i.e. fatigue life) consisted of residual critical strength and stresses occurring at each layer (0 and 90 layers) and interlayer. Moreover, the fatigue failure occurred because the residual critical strength of each layer and interlayer decreased with dependence of their microdamage densities, so that the fatigue life can be predicted by evaluating microdamage behavior in fatigue process. (orig.) 14 refs.
A test program was conducted under contract to Sandia National Laboratories to investigate water/steam effects on elevated temperature low cycle fatigue and creep-fatigue of Alloy 800. This report presents interpretation and analysis of the test results. Tubular specimens with water sealed inside were cycled to failure under strain control. Tests were conducted to 616K (650/sup 0/F) and 922K (1200/sup 0/F); some at 922K included tensile or compressive hold periods to simulate creep-fatigue conditions. The tubular specimens showed significantly lower lives than solid bar specimens cycled at equivalent strain ranges. Rough internal surfaces contributed to early crack initiation with these specimens. Inclusion of hold periods caused further large reductions in cycles to failure.
During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.
Diurnal and seasonal thermal constancy, a greatly delayed seasonal temperature maximum, and summer cool and winter warm conditions characterize the stream environment below a deep-release dam in Colorado. Low diversity index and equitability values and changes in macroinvertebrate species composition may result from failure of the temperature regime to provide the thermal stimuli essential for various life-cycle phenomena. It is hypothesized that the following sublethal effects, directly or indirectly resulting from the modified temperature regime, may further alter macroinvertebrate community structure: reduction of niche overlap and a shift toward an equilibrium community as a consequence of reduced environmental fluctuation; more intense competition associated with greater productivity; elimination of major invertebrate predators; and failure of the limited temperature range to provide optimal temperatures for various physiological ...
The first cardiac pacemaker implants occurred in the late 1950s and involved insertion of epicardial or epimyocardial leads and abdominal pulse generators. By the mid 1960s, cardiologists were making attempts to insert transvenous leads into the right ventricle. These early unipolar leads had large, polished, high polarization electrodes, no fixation device, and no lumen in which to place a stylet for lead positioning. The lead implantation procedures were usually long and the irradiation to both patient and operator excessive. Pulse generators were powered by zinc-mercury cells, which were large, unreliable, and prone to sudden output failure. Postoperative complications such as lead dislodgement, exit block, and premature power source failure were very common with most patients requiring...
Microbonding of the CMS Tracker Inner Barrel (TIB) and Tracker Inner Disks (TID) modules was shared among six different Italian Institutes. The organization devised and the infrastructure deployed to handle this task is illustrated. Microbonding specifications and procedures for the different types of TIB and TID modules are given. The tooling specially designed and developed for these types of modules is described. Experience of production is presented. Attained production rates are given. An analysis of the microbonding quality achieved is presented, based on bond strengths measured in sample bond pull tests as well as on rates of bonding failures. Italian Bonding Centers routinely performed well above minimum specifications and a very low global introduced failure rate, at the strip level, of only $\\sim$0.015 \\% is observed.
The author applies the GO methodology to reliability analysis of the offsite power supply system of Daya Bay NPP. The direct quantitative calculation formulas of the stable reliability target of the system with shared signals and the dynamic calculation formulas of the state probability for the unit with two states are derived. The method to solve the fault event sets of the system is also presented and all the fault event sets of the outer power supply system and their failure probability are obtained. The resumption reliability of the offsite power supply system after the stability failure of the power net is also calculated. The result shows that the GO methodology is very simple and useful in the stable and dynamic reliability analysis of the repairable system
The article maps the risk management failures within Anglo Irish Bank, showing that, when banks are systemic in nature, poor internal corporate governance within a Minsky credit cycle can lead to destabilising macroeconomic conditions, which may prolong the effects of a credit-induced downturn. The article highlights a failure of management at Anglo Irish Bank to establish and measure firm-level risks and develop appropriate internal controls to support a culture of prudent credit management. We propose the adoption of a novel supervisory architecture based on the meta-risk regulatory philosophy, which is designed to strengthen risk management practices at banks.
The high temperature abrasive wear resistant of the composites with different Al{sub 2}O{sub 3} volume fractions, particle coating and size were investigated and the failure action of composites under different conditions at high temperature was analyzed. The results showed that the high temperature abrasive wear resistant of composite with Ni coating and wide size and 39% volume fraction of particle is the best among all composites examined. (orig.)
DescriptionThis project investigates in silico the interactive consequences of breeding for parasite resistance and nutritional environment on livestock productivity. The thesis of the work is that conflicting evidence regarding the consequences of breeding for parasite resistance arises from the failure to consider the interactions between host genetics and nutritional environment. Starting with a framework that accounts for the consequences of host nutrition on the development of parasitism, we will (1 [continued...
The hepatic removal of albumin-bound substances from plasma requires that they dissociate from albumin. Using indirect methods, we and others have proposed that dissociation may be catalyzed by interaction...Full Text Available
We reported previously that Fas-induced hepatic failure in normal mice was attenuated or prevented by exogenous transferrin (Tf), particularly apoTf. Here we show in C57BL6J/129 mice with genetic...Full Text Available
The electrogeometric model cannot consider the influence of some parameters on the screening of the wire conductor of the H.V. lines. For analysing the influence of these parameters (the conductor potential, the influence of the distance from phase conductor to earth wire, the influence of the reducing factor of the striking earth distance, the earth slope, etc.), the Monte Carlo method is preferable. The influence of the earth slope on the screening effect of the wire conductor for different conditions is presented in this paper. (author)
Silicones have many desirable properties and as a result are incorporated into a wide range of products. However, they present unique problems that result from their propensity to outgas resulting in residue formation at unexpected places. Hence, the silicone conundrum?when to use these materials and when to beware of potential pitfalls. In this article, an outgassing mechanism unique to ?low outgassing? silicones is discussed. Examples are given where this has led to failures and remediation steps are highlighted.
We report that the fission yeast nucleoporin Nup124p is required for the nuclear import of both, retrotransposon Tf1-Gag as well as the retroviral HIV-1 Vpr. Failure to import Tf1-Gag into the nucleus...Full Text Available
Biomass tensile and shear ultimate failure stresses were measured with the aim of identifying biomass 'weakest mode of failure' or 'natural fracture point' as a basis for future grinder designs. Switchgrass (Panicum virgatum L.) ultimate stresses were determined for Alamo and Kanlow varieties over ranges in maturity and moisture content. Alamo had greater ultimate tensile stress than Kanlow (P=0.0091), with mean values of 97.8 and 89.7MPa, respectively. Alamo had greater ultimate shear stress than Kanlow (P=0.0091), with mean values of 20.5 and 17.9MPa, respectively. Shear was the 'weakest mode of failure'. Grinders that use knives, shear bars, and mechanical pinch points that apply opposed-sliding actions are expected to be more energy efficient. Mean ultimate tensile stress and shear stress were significantly different between switchgrass varieties. A survey of ...
Statistical data on individual types of foreign NPPs including reliability and safety indices are given. It is noted that capacity factors (CF) in 1985 were higher for PWRs. Japan has the highest CF-98.5% in the world. One of main causes of NPP shutdown remains the primary circuit equipment failure in connection with different corrosion types (intercrystalline, pitting, denting-corrosion etc.). Effect of all volatile treatment on enhancement of NPP reliabiity is shown. Technical BWR characteristics are presented.
The nuclear power plants with WWER type reactors are characterized by horizontally situated steam generators (SG). During seismic event the horizontal and vertical ground accelerations induce fluid motion in directions of longitudinal and transversal axis. Resulting dynamic forces act on the SG attachment and could cause the failure of screws. In obvious PSA scenarios, these phenomena are classified as a indirect induced LOCA. In this paper the effects of transversal sloshing of fluid are analyzed.
To make a quantitative comparison of risks between the SNR 300 and a modern PWR (Biblis B), the consequences of an accident or the extent of damage of a release of radionuclides to the environment due to an accident are estimated by computer programs for accident consequence models. The accident analysis includes an analysis of events for Bethe-Tait accidents with failure of the outer containment. The FGSB release rates are compared with those of the Society for Reactor Safety (GRS). (HP).
Giving many examples, the contribution shows how pump operators may influence the life, efficiency and overall cost of their pumps. Further, it is shown that both the detection of unfavourable or non-optimal operating conditions and the identification of causes necessitate extensive knowledge and experience. (orig.)
Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.
This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.
The objective of this work group was to identify obstacles to the development of better risk management practices and performance standards in the pipeline industry. An outline of developments in pipeline risk assesment management was presented, including an update of the Risk Based Design and Assessment annex and other CSA Z662 code developments. It was suggested that progress in risk management require that acceptable levels of risk and reliability need to be defined. Environmental and safety consequence analysis was recommended, as well as failure frequency estimation and assessment of distribution systems. Guidelines for Integrity Management Programs (IMPs) were reviewed. It was noted that CSA Z662 will become mandatory for sour gas in 2005 and may become mandatory for all onshore pipelines in 2007. Operating company procedures in relation to hazards with significant consequences were discussed. It was noted that companies should assess risks associated with ...
This article describes the techniques for monitoring electric power transformers applied by the Light to select and recover critical unities. The plan involved 20 and 40 MV A equipment and, as a reflex of the technique application, presented a substantial failure reduction.
Recent literature indicates that torsion of the left ventricle (LV) is a promising predictor for response to cardiac resynchronisation therapy (CRT). Among patients with severe heart failure, 45 to 75% of patients show rigid body rotation, where the base and apex rotate in the same direction, instead of normal, opposite rotation. The occurrence of this phenomenon seems to be a good indicator for response to CRT. From this review, it can be concluded that LV torsion might be a welcome addition to current selection criteria.
Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues.
A thesis is presented on improving the understanding of the fatigue properties of wood and fatigue failure mechanisms in the design of wind turbine blades. Three main areas were researched: the effect of R ratio on fatigue life, the effect of moisture on fatigue life and the development of cumulative damage laws. Tests were carried out on mainly four-ply laminates. Recommendations to future work are outlined. (U.K.).
Recent scholarship has explored the process by which modern commercial and property law came into being in the non western world, and has emphasized the role played by colonialism and conquest in this process. Using a case study from colonial India, this article suggests that the coding of commercial law was influenced more by commercialization than by the nature of the state, and was an endogenous response to the failure of local custom and common law to secure frictionless trade.
Mutation breeding in one of the cultigens TMV-5 in Sesamum is undertaken with 5 kr, 10 kr, 15 kr, 20 kr, 60 kr and 80 kr, dosages of gamma-rays. 60 kr and 80 kr dosages were found to be lethal from the complete failure of seed germination. The mutagen had a heterotic effect on the different characters and the promising variants obtained in this programme are proposed to be maintained by pureline breeding for their possible release as new varieties. (author).
The polymer industry is a young industry that has undergone tremendous growth and change over the last sixty years. Many important discoveries in polymer science have been accidental. Most of the learning has been by trial and error and most of the understanding is still basically empirical--make a polymer material or compound and then put it to the test to study what it is and how it performs. This article provides an overview of what polymers and polymer compounds are, why they behave as they do, and it discusses several examples of failures of rubber and plastic components.
It is desirable to avoid vibration problems by following appropriate guidelines and specifications at the design stage. Accordingly, design specifications were developed to prevent tube failures due to vibration in nuclear steam generators and liquid heat exchangers. These specifications are outlined in this report. (author). 14 refs., 2 figs.
We report for the first time a case of a 54 years old man with a fatal motorcycle accident due to an external bleeding compression of left internal mammary artery graft to the left anterior descending...Full Text Available
Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such ...
This article examines the impact of mist-eliminator (ME) design and reliability on the performance of flue gas desulfurization (FGD) processes. ME failures are the second most common cause of FGD system outages. ME design also affects the chemistry of the FGD processes. The author considers the ME the linchpin of the whole FGD process system.
The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.
Often measures of protection and restoration of reinforced concrete structures are not taken until damage occurs which affects power plant operation. These failures can be avoided by predictive civil engineering maintenance and repair. The consequent application and implementation of a life-time management system for power plant buildings is being suggested. (orig.)
Besides industrial agglomerations suffering from excessive pollution of water, air, and soil, there are areas in the German Democratic Republic where beautiful scenery at first glance seems to be intact owing to the absence of large industries. That environmental problems exist also in the coastal regions of the German Democratic Republic is shown in this report. Some of the environmental sins mentioned, which are due to human failure, would seem to the editor to be not just GDR specific. (orig.).
The impact of the rewetting process on the performance of waste containers at the Yucca Mountain repository is analyzed. This paper explores the impact of the temperature-humidity relationships on pitting corrosion failure of stainless steel containers for different areal power densities (APDs)in the repository. It compares the likely performance of containers in a repository with a low APD, 55 Kw/acre, and a high APD, 110 kW/acre.
Using the Philips DRM distributed real-time multiprocessing system, designers can implement high-performance computer systems using VME hardware and the C programming language. The system provides a virtual-processing environment in which several 68000 CPUs share the workload. There are no centralized components, and tasks can be assumed by the rest of a system in the event of an individual processor's failure.
This report discusses a representation scheme of device failures anticipated in nuclear power plant, to describe related knowledge in a computer software. Coping ability covering a wide range of physical events is desired in plant operators and maintenance staffs, but it is impractical to give them a set of experience to cover the all possible events in the education/training curriculum. However, in case that their knowledge of plant design and of generally-known physical principles are enforced, their ability of cause identification and of appropriate responding actions against inexperienced events are expected to be enhanced, by combining the basic engineering and physical knowledge. Most of the anomalies anticipated in nuclear power plants are initiated as an incipient failure in some auxiliary equipment initially affecting only within the relative subsystem and hiding from the central control room, and then are propagated to deviate process ...
The 1977 version of the Simpson-Puls-Dutton model appears to be the most amenable with respect to utilizing known or readily estimated quantities. The Pardee-Paton model requires extensive calculations involving estimated quantities. Recent observations by Koike and Suzuki on vanadium support the general assumption that crack growth in hydride forming metals is determined by the rate of hydride formation, and their hydrogen atmosphere-displacive transformation model is of potential interest in explaining hydrogen embrittlement in ferrous alloys as well as hydride formers. The discontinuous nature of cracking due to hydrogen embrittlement appears to depend very strongly on localized stress intensities, thereby pointing to the role of microstructure in influencing crack initiation, fracture mode and crack path. The initiation of hydrogen induced failures over relatively short periods of time can be characterized with fair reliability using measurements of the ...
This paper outlines aspects of the procedures adopted within Nuclear Electric plc for the assessment of Leak before Break arguments and the consequences arising from leakage and/or pipe failure. Only new aspects are considered such as creep, leakage, temperature and over pressure assessments and pipe whip. 7 refs.
The applicability of conventional strength hypotheses in the long-term creep range was examined by means of multiaxial loaded small and large-scale specimens of 1% CrMoNiV-steel at 550deg C. The experimentally determined deformation behaviour in the primary and secondary creep range was simulated by means of a finite element analysis. The creep deformation capacity is influenced by the degree of multiaxiality. The validity of a strength hypothesis depends on the type of load and on deformation resp. failure criteria. (orig.).
The incidence of anogenital malignancies is greatly increased in patients who have received a renal transplant, but this has not been well studied in patients receiving maintenance dialysis. Our aim was to assess the incidence of these malignancies in patients on dialysis and compare these to transplanted patients. The age standardized incidence ratio (SIR) for anogenital malignancies was calculated by comparing the observed number of malignancies to the expected number. The expected number was calculated by multiplying the age specific incidence rates for each malignancy by the person years at risk in 5-year age cohorts. Of 15,820 patients in the Australia and New Zealand data base, 8,215 had received a renal transplant. A total of 39,750 person years at risk were contributed by patients who had received a renal transplant, while 29,276 person years at risk were contributed by dialysis patients who had ...
Background and purpose: A diagnosis of malignancy and its treatment is a very stressful time for patients and their families. This study was conducted to determine the impact of more intensive written information on patients' anxiety levels. The secondary aim was to determine the impact of this information on patients' satisfaction levels. Materials and methods: This prospective randomized trial consisted of patients with a pathological diagnosis of cancer having radical radiotherapy (RT). Patients were randomized to receive the more intensive information (including written information and a telephone call from the research nurse) or not to receive the more intensive information at the time of their initial consultation with the radiation oncologist. Study questionnaires measuring anxiety (STAI form) were completed prior to their first consultation (baseline) at the time of simulation (pre-RT) and at the completion of radiotherapy. A second ...
The interaction between acidic fluoride solution and beta titanium alloy was investigated to explore the changes that occur in beta titanium alloy by fluoride-containing acetic acid solutions. For this, alloy crystal structure, tensile strength, and elements released from the alloy wires were determined using four solutions (0.05%/pH 6, 0.05%/pH 4, 0.2%/pH 6, and 0.2%/pH 4) for 1 or 3 days. The immersed wire did not form any identifiable new crystal structure compared with the as-received wire. The tensile strength of the immersed wires was significantly reduced compared to the as-received wires in the test solutions if the period of immersion increased from as-received to 3 days. The fractured area of the immersed wire was reduced compared to the as-received one. The dimple pattern at the inner part and a cup-cone morphology at the outer part of the fractured wires were similar in both ...
In the report the results of the estimations of radiological risk of various stages of decommissioning of nuclear submarines are presented. At occurrence on nuclear submarine the heavy failure, relating to the class hypotetical volume of acting of radionuclides in atmosphere can reach 1.6E(15) Bq. Results of estimations probable doses on an axis of a trace of a radioactive loop show, that at distribution of radionuclides during atmospheric carry to 'agreed' settlement (500-1000 m) the maximum doses on its territory can make: about 6.0E(-3) Sv (for the whole body); 3.0E(-3) Gy for the leather (basal layer); 6.3E(-2) Gy for the lungs (acute exposure) and up to 1.8 Gy for the thyroid gland. Hypotetical failure for the estimation of the greatest possible radioecological consequences for hydrobiocenosis is considering, connected with single discharge of liquid radioactive waste (LRW) in water area. At navigating failure of the ...
2,3-Dimercaptosuccinic acid (DMSA) is a new orally active heavy metal chelator for the treatment of childhood Pb intoxication on an outpatient basis. The influence of DMSA, as well as other chelating agents, on gastrointestinal 203Pb absorption and whole-body "2"0"3Pb retention was examined. Groups of Sprague-Dawley rats (230-260 g) were gavaged with a solution containing approximately 25 mg/kg Pb [as Pb(NO_3)2] plus 15 microCi "2"0"3Pb. Some groups were then immediately given 0.11 mmol/kg of either DMSA, CaNa2EDTA, D-penicillamine, or BAL by oral gavage, while other groups received the same drugs by ip injection. Control groups received solutions of the drug vehicles po or ip. Whole-body Pb retention and gastrointestinal Pb absorption (whole body retention + urinary Pb excretion) were significantly decreased in rats that received DMSA po. This finding implies that the use of DMSA to treat childhood lead intoxication on an ...