WorldWideScience
1

IEEE [Institute of Electrical and Electronics Engineers] standards and nuclear software quality engineering  

International Nuclear Information System (INIS)

Significant new nuclear-specific software standards have recently been adopted under the sponsorship of the American Nuclear Society and the American Society of Mechanical Engineers. The interest of the US Nuclear Regulatory Commission has also been expressed through their issuance of NUREG/CR-4640. These efforts all indicate a growing awareness of the need for thorough, referenceable expressions of the way to build in and evaluate quality in nuclear software. A broader professional perspective can be seen in the growing number of software engineering standards sponsored by the Institute of Electrical and Electronics Engineers (IEEE) Computer Society. This family of standards represents a systematic effort to capture professional consensus on quality practices throughout the software development life cycle. The only omission-the implementation phase-is treated by accepted American National Standards Institute or de facto standards for ...

1988-06-12

3

Howard Hughes Medical Institute dose assessment survey  

Energy Technology Data Exchange (ETDEWEB)

Biomedical science researchers often express frustration that health physics practices vary widely between individual institutions. A survey examining both internal and external dose assessment practices was devised and mailed to fifty institutions supporting biomedical science research. The results indicate that health physics dose assessment practices and policies are highly variable. Factors which may contribute to the degree of variation are discussed. 2 tabs.

1996-12-01

4

CT-Expo - a novel program for dose evaluation in CT  

International Nuclear Information System (INIS)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey ...

2002-12-01

5

Range and modulation dependencies for proton beam dose per monitor unit calculations  

UK PubMed Central (United Kingdom)

Calculations of dose per monitor unit (D∕MU) are required in addition to measurements to increase patient safety in the clinical practice of proton radiotherapy. As in conventional photon and...Full Text Available

2009-02-01

6

Savannah River Site dose control  

Energy Technology Data Exchange (ETDEWEB)

Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.

1992-01-01

7

Savannah River Site dose control  

Energy Technology Data Exchange (ETDEWEB)

Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.

1992-06-01

8

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

9

Absorbed dose and dose equivalent depth distributions for protons with energies from 2 to 600 MeV  

Energy Technology Data Exchange (ETDEWEB)

Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).

1989-01-01

10

Universal Basic Education in Nigeria: Availability of Schools' Infrastructure for Effective Program Implementation  

Science.gov (United States)

This paper examines the availability and adequacy of schools' infrastructural facilities for implementation of the Universal Basic Education program in Nigeria. Adopting the "ex post facto" design, the researchers used existing school data on physical facilities, including a survey of key stakeholders in the education sector. Data analysed revealed inadequacy of physical facilities for effective implementation of the UBE program. It was accordingly recommended that government at the national, state and local levels show better commitment to the implementation of the Universal Basic Education program. (Contains 3 figures and 4 tables.)

2008-02-01

11

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

12

A marine compartment model for collective dose assessment of liquid radioactive effluents  

International Nuclear Information System (INIS)

A compartment model is described which is currently used by the Ministry of Agriculture, Fisheries and Food to calculate collective radiation exposure due to liquid radioactive wastes discharged to sea from UK nuclear sites. Collective dose is a useful indicator of the radiological impact of a disposal practice and is one of the quantities needed to show compliance with the ICRP system of dose limitation. The model has been used for the purposes of the Sizewell Inquiry to predict the collective radiation exposure from reactor operation at Sizewell and, on the basis of current Sellafield experience, correlations between dose and discharge for disposals of fuel reprocessing wastes. (author).

1982-01-01

13

The development of thyroid dose assessment software for nuclear or radiological emergency  

International Nuclear Information System (INIS)

Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)

2006-12-01

14

Effect of Nordic diets on ECOSYS model predictions of ingestion doses  

British Library Electronic Table of Contents (United Kingdom)

The ECOSYS model is used to estimate ingestion dose in the ARGOS and RODOS decision support systems for nuclear emergency management. It is recommended that nation-specific values for several parameters are used in the model. However, this is generally overlooked when the systems are used in practice. We have estimated first year ingestion doses in two scenarios with wet and dry deposition of 137Cs, using the ECOSYS model. We calculated doses for each country using national dietary data while keeping all other parameters at their default values. These dose calculations were then used to estimate the variation in ingestion doses resulting from the variation in the diets only. The dietary data demonstrated that the average consumption of milk, meat and vegetables varied by a factor of 2-4 am...

2010-01-01

15

Analysis of photon beam exit dose using photon point kernels  

International Nuclear Information System (INIS)

The Monte Carlo method is used to analyse the dose fall-off at the exit surface of a megavoltage photon beam. The convolution/superposition method of dose calculation using Monte-Carlo-generated homogeneous photon kernels is shown to be in error for exit dose calculation. Instead, photon kernels that incorporate modelling of the exit surface were generated, also using Monte Carlo, to analyse the problem, and the calculated dose fall-off using these kernels agrees well with measured data. In addition, the physics underlying the characteristics of the dose fall-off is analysed based on complete Monte Carlo modelling. Practical improvements to the convolution/superposition method are suggested. (Author).

16

Treatment of uteral cancer by the brake irradiation (25 MeV)  

International Nuclear Information System (INIS)

The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.

17

Influence of wood extractives in the polymerization of methyl methacrylate by gamma irradiation  

International Nuclear Information System (INIS)

Those materials that can be extracted from pine or oak by ether, ethanol, methyl methacrylate (MMA), or benzene--alcohol all act as inhibitors in the #gamma# polymerization of MMA--wood composites. It was found that preirradiation of either the wood or of the wood--monomer combination reduces or eliminates the inhibitory effect. The most practical industrial solution to this problem is to increase the dose, thereby achieving high molecular polymer in the composite. However, the presence of a maximum in the molecular weight--dose curves means that each wood--monomer pair may have a different optimum dose.

1975-01-01

18

Clinical application of dosimetry in electron beam therapy  

International Nuclear Information System (INIS)

In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).

19

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the ...

2007-08-01

20

Principles of protection: a formal approach for evaluating dose distributions  

International Nuclear Information System (INIS)

One of the central issues in radiation protection consists in determining what weight should be given to individual doses in relation to collective or aggregated doses. A mathematical framework is introduced in which such assessments can be made precisely in terms of comparisons between alternative distributions of individual doses. In addition to evaluation principles that are well known from radiation protection, a series of principles that are derived from parallel discussions in moral philosophy and welfare economics is investigated. A battery of formal properties is then used to investigate the evaluative principles. The results indicate that one of the new principles, bilinear prioritarianism, may be preferable to current practices, since it satisfies efficiency-related properties better without sacrificing other desirable properties.

2006-03-01

21

CT-Expo - a novel program for dose evaluation in CT; CT-Expo - ein neuartiges Programm zur Dosisevaluierung in der CT  

Energy Technology Data Exchange (ETDEWEB)

CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey ...

2002-12-01

22

Estimations of population doses and risk estimates from occupational exposures in Japan, 1978, 2  

International Nuclear Information System (INIS)

The population doses and risks of stochastic effects from occupational exposures in Japan in 1978 were estimated on the basis of a nation-wide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 82,500 workers other than the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the offitial publication of the Japan Nuclear Safety Commission. The total number of workers except for nuclear power stations was estimated to be about 170,000 persons. Radiation works were subdivided as follows: medical works including dental; nondestructive inspectional; non-atomic energy industrial; research and educational; atomic energy industrial and nuclear power industrial. The annual collective dose equivalents were estimated to be about 6,000 man rem for medical workers, 450 man rem for non-destructive inspectional, ...

1981-01-01

23

Practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

Outage is a specific period of time for radiation protection in a nuclear power plant, in which the radiation risk and collective dose are both at the highest level. In this article, the practice and experience of occupational exposure control in the outages of Daya Bay Nuclear Power Plant are introduced through following aspects: early involvement in outage preparation by radiation protection service, control of source term, radiation protection and safety management in the outage implementation processes, the effectiveness of the plant's safety management network and overall involvement of all staffs of the plant, experience feedback and continuous improvement in radiation protection management, etc

2004-05-01

24

Stereotactic body radiotherapy for unresectable cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To report outcomes of a single institution study of stereotactic body radiotherapy (SBRT) for unresectable cholangiocarcinoma. The dose-volume dependency of the observed gastrointestinal toxicity is explored. Methods and materials: Twenty-seven patients with unresectable cholangiocarcinoma (n = 26 Klatskin tumours and one intrahepatic cholangiocarcinoma (IHCC)) were treated by linac-based SBRT. The dose schedule was 45 Gy in three fractions prescribed to the isocenter. Results: The median progression-free survival and overall survival were 6.7 and 10.6 months, respectively. With a median follow-up of 5.4 years, 6 patients had severe duodenal/pyloric ulceration and 3 patients developed duodenal stenosis. Duodenal radiation exposure was higher in patients developing moderate to high-grade gastrointestinal toxicity with the difference in mean maximum dose to 1 cm"3 of duodenum reaching statistical significance. A ...

2010-01-01

25

Challenges in validating the sterilisation dose for processed human amniotic membranes  

Energy Technology Data Exchange (ETDEWEB)

Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10{sup -1}. This paper describes our experience in using the IAEA ...

2007-11-15

26

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained ...

27

Estimation of dose in irradiated chicken bone by ESR method  

Energy Technology Data Exchange (ETDEWEB)

The author studied the conditions needed to routinely estimate the radiation dose in chicken bone by repeated re-irradiation and measuring ESR signals. Chicken meat containing bone was {gamma}-irradiated at doses of up to 3kGy, accepted as the commercially used dose. The results show that points in sample preparation and ESR measurement are as follows: Both ends of bone are cut off and central part of compact bone is used for experiment. To obtain accurate ESR spectrum, marrow should be scraped out completely. Sample bone fragments of 1-2mm particle size and ca.100mg are recommended to obtain stable and maximum signal. In practice, by re-irradiating up to 5kGy and extrapolating data of the signal intensity to zero using linear regression analysis, radiation dose is estimated. For example, in one experiment, estimated doses of chicken bones initially irradiated ...

1998-03-01

28

Radiological assessment of past, present and potential sources to environmental contamination in the Southern Urals and strategies for remedial measures (SUCON)  

Energy Technology Data Exchange (ETDEWEB)

This report summarises work done on the SUCON Project during 1996-1999 (European Commission Contract No. FI4C-CT95-0001). The project has focused on three major objectives: 1) An assessment of the radiological consequences of the contamination of the South Urals and the Ob river system from the production of plutonium at 'Mayak', 2) The development of models to calculate doses to individuals and populations in the South Urals using environmental data, and 3) The intercomparison, harmonisation and standardisation of techniques used in dose reconstruction and specification of good practice in particular with regard to remedial measures. (au)

2000-12-01

29

Progress and challenges in the discovery of macrofilaricidal drugs  

British Library Electronic Table of Contents (United Kingdom)

Control of human filarial infections currently depends on chemotherapeutic strategies predominantly directed at microfilariae. Doxycycline therapy in an extended daily dose regimen sterilizes and kills adult stages, but the utility of this drug for routine field use remains an issue of concern. No macrofilaricidal drugs with efficacy after one or two doses are available for use, delaying the achievement of the elimination or eradication of onchocerciasis and lymphatic filariasis. Moxidectin, a macrocyclic lactone, is currently in clinical trials for onchocerciasis. A few other drugs that have already been approved for use in veterinary practice or in human medicine for other indications are available for investigation. Early drug discovery pipelines are poorly populated and the process of ...

2011-01-01

30

Exposure estimation of personnel around patients after radionuclide therapy by Monte Carlo method and integration method  

International Nuclear Information System (INIS)

Objective: To estimate exposure dose of personnel around patients by Monte Carlo method and integration method. Methods: Exposures were estimated by a Monte Carlo practical program with Visual Basic 6.0 and integration method using 'pen-and-paper'. Results: Exposures for rectangle and ellipse sources were calculated. The difference between different methods for various sources were 0.88% and 0.61%, respectively. Conclusion: The results estimated by Monte Carlo method are close to those of integration method. It is illustrated that doses of other people estimated by Monte Carlo method are significant

2001-08-01

31

Development and utilization of the nominal standard dose for the tolerance dose to sound tissue with radiation t: m1herapy  

International Nuclear Information System (INIS)

The utilization of the Ellis-formula for the determination of the tolerance of normal connective tissue is described. Beyond this, the formula is adapted to so-called critical organs. The individual suppositions implicated by the Ellis-formula are commented. Because of the verifyable congruency of the Ellis-formula with data obtained in clinical practice also by other authors, this conception is presented for the provisional determination of the limits of tolerance of normal tissue together with a computerized programme elaborated for use in different therapeutic techniques. (orig.).

1976-01-01

32

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper summarize the practice of the standards ...

2009-03-01

33

The importance and unique aspects of radiation protection in medicine  

British Library Electronic Table of Contents (United Kingdom)

Radiation protection in medicine has unique aspects and is an essential element of medical practice. Medical uses of radiation occur throughout the world, from large cities to rural clinics. It has been estimated that the number of medical procedures using radiation grew from about 1.7 billion in 1980 to almost 4 billion in 2007. In spite of these large numbers, there are many parts of the world without adequate equipment, where the ability to perform additional medical procedures would likely result in a net benefit. Medicine accounts for more than 99.9% of the per caput effective dose from man-made sources. The goal in medical exposure is not to give the lowest dose, but to provide the correct dose to enable the practitioner to make the diagnosis or cure a tumour. Too little or too much ...

2010-01-01

34

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

35

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

36

Ionizing radiation effect on sealant properties  

International Nuclear Information System (INIS)

Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.

37

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit  

International Nuclear Information System (INIS)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.)

38

The effect of patient shield position on gonad dose during lumbar spine radiography  

Energy Technology Data Exchange (ETDEWEB)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population ...

2010-05-15

39

The effect of patient shield position on gonad dose during lumbar spine radiography  

International Nuclear Information System (INIS)

Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population ...

2010-05-01

40

Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs  

International Nuclear Information System (INIS)

Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5"0-10"0. But with intensity-modulated arc therapy (IMAT), the variation in shape and dose per degree can be large enough to require a finer angular spacing. With the increase in the number of beams, a deterministic dose calculation method, such as collapsed-cone convolution/superposition, will require proportionally longer computational times, which may not be practical clinically. We propose to use a homegrown Monte Carlo kernel-superposition technique (MCKS) to compute doses for rotational delivery. The IMAT plans were generated with 36 static beams, which were subsequently ...

2008-09-07

41

Preliminary study of the application of natural olivine in Cenozoic dating  

Energy Technology Data Exchange (ETDEWEB)

The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL ...

2006-08-15

42

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...

43

Dose assessment and behavior of tritium in environmental samples around Wolsong nuclear power plant.  

Science.gov (United States)

For the estimation of the dispersion trend of tritium discharged from the Wolsung nuclear power plant, the present level of tritium in environmental samples in the vicinity of the Wolsong site has been studied. On the basis of tritium concentrations in environmental samples, the effective dose due to tritium has been estimated for an individual and population within a 16 km radius from the Wolsong site. The annual effective dose of tritium to an inhabitant around the Wolsong site ranged from 0.15 microSv y-1 to 1.3 microSv y-1. The dose level was negligible and much lower than some applicable standards, i.e. the limit on exposure from nuclear fuel cycle to the general public as recommended by ICRP (1 mSv y-1) or US EPA's limit (0.25 mSv y-1). The collective dose to the total population within a 16 km radius from the site, 1.2 x 10(-2) man.Sv y-1 was much lower than 1 man.Sv y-1, an applicable criterion ...

1999-04-01

44

A heterogeneous dose distribution in simultaneous integrated boost: the role of the clonogenic cell density on the tumor control probability  

Energy Technology Data Exchange (ETDEWEB)

IMRT with inverse planning allows simultaneous integrated boost strategies that exploit the heterogeneous dose distribution within the planning target volumes (PTVs). In this scenario, the location of cold spots within the target becomes a crucial issue and has to be related to the distribution of the clonogenic cell density (CCD). The main aim of this work is to provide the means to calculate the optimal prescription dose in a relative inhomogeneous dose distribution. To achieve this, the prescription dose has to be assigned to obtain the same tumor control probability (TCP) as the ideal homogeneous distribution, taking into account different CCDs in different PTVs (i.e. visible and subclinical regions). An adapted formulation of the linear-quadratic model, within the F-factor formalism, has been derived to preserve a chosen TCP value for the whole target volume. The F-factor has been investigated to ...

2008-10-07

45

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the ...

2007-03-15

46

Dosimetric characteristics of backscattered electrons in lead  

Energy Technology Data Exchange (ETDEWEB)

In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) wasdefined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF with the beam energy incident on the ...

2000-07-01

47

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

Energy Technology Data Exchange (ETDEWEB)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-08-01

48

Report of the IPSM working party on low- and medium-energy x-ray dosimetry  

International Nuclear Information System (INIS)

New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).

1991-01-01

49

Exclusion, exemption and clearance in the mining and minerals industry - A review of the concepts from a South African perspective  

International Nuclear Information System (INIS)

The risks from mining and processing of ores is reviewed on a generic basis with particular reference to some of the confusions which can arise due to lack of consistency or common logic in the use of exclusion, exemption and clearance. The difference in exclusion and exemption are challenged by comparing doses received in high background radiation areas and the doses received from a mining practice. The common principle of risk to the human species is not applied consistently. The differences between IAEA recommendations and local regulatory conditions are compared, and the use of exemption levels as clearance levels is considered. A case study on management of mine tailings is presented with special focus on the use of clearance levels. In all areas of review the interpretation of regulation is subject to confusion resulting from inconsistencies which can distort free market economics. (author).

1997-05-06

50

Enhanced spectral discrimination through the exploitation of interface effects in photon dose data  

International Nuclear Information System (INIS)

The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the ...

2004-02-01

51

Tritium bioassay and dosimetry at a CANDU reactors  

Energy Technology Data Exchange (ETDEWEB)

Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.

1996-07-01

52

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. ...

2010-07-07

53

Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons  

Energy Technology Data Exchange (ETDEWEB)

In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the ...

2007-07-01

54

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: The general population is daily exposed to chronic, low doses of ionizing radiation (IR) from both natural and artificial sources. The biological consequences of acute, high dose IR exposure can be readily determined; however, the nature and significance of low dose, low dose-rate IR effects are still the subject of debate. Confounding the issue, are the phenomena collectively referred to as the Radiation-induced Bystander Effect (RIBE). The RIBE describes a collection of in vitro observations that suggest the presence of a soluble, transmissible factor(s) released from irradiated cells that can induce a biological response in un-irradiated cells. The induction, nature and magnitude of the RIBE varies between cell culture systems, radiation sources and end-points measured. Efforts to confirm the presence of the RIBE in vivo have been confined to in vivo-like culture systems and limited work ...

2006-01-01

55

Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system  

International Nuclear Information System (INIS)

In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear accelerator types. To speed up the calculations, a number of ...

2000-04-01

56

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. Teil 2. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden Definitionen von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2001-07-01

57

Reference values for X-ray diagnostic investigations. Some thoughts on the relation between expenditure and benefit; Referenzwerte fuer roentgendiagnostische Untersuchungen. T. 1. Ueberlegungen zur Verhaeltnismaessigkeit von Nutzen und Aufwand  

Energy Technology Data Exchange (ETDEWEB)

In the first part of this contribution, the definition of reference values is given and the theoretical and practical problems in the application of this concept are discussed. In this connection, the present resources on instrumentation and the technical requirements for dose assessment are described. In the second part, some consequences are taken and proposals for further actions are made. (orig.) [German] Im ersten Teil des Aufsatzes werden die Definition von Referenzwerten in der radiologischen Diagnostik untersucht und die theoretischen und praktischen Probleme der Umsetzung des gesamten Konzepts eroertert. In diesem Zusammenhang werden auch der gegenwaertige Geraetebestand und die technischen Voraussetzungen zur Dosisermittlung beschrieben. Im zweiten Teil werden daraus Schlussfolgerungen gezogen und Vorschlaege zum weiteren Vorgehen gemacht. (orig.)

2000-07-01

58

Nuclear fragmentation of clinical silicon beam  

Energy Technology Data Exchange (ETDEWEB)

Heavy ions used for biomedical studies fragment when they pass through matter. It is known that different fragments cause different types of biological damage. In this paper, results pertaining to differrent kinds of secondary fragments produced by a /sup 28/Si beam at 463 MeV/nucleon in its interaction with nuclear emulsion are presented. It is observed that the production frequencies of secondary fragments are independent of the target. Partial production cross sections and fluences of the secondary fragments are also discussed. The partial production cross sections for different fragments at three lower energy ranges are practically the same within their statistical errors except for the cross section for Li fragments, which is larger by almost a factor of 1.5 at the lowest energy investigated. The dose contributions of the primary Si beam and its components at different points of the Bragg curve are presented for two different energy ...

1985-02-01

59

Case?control study of knee osteoarthritis and lifestyle factors considering their interaction with physical workload  

British Library Electronic Table of Contents (United Kingdom)

Aims The aim of this study is to examine the dose?response relationships between age, ?lifestyle factors?? (body mass index, tobacco smoking, sports), and symptomatic knee osteoarthritis in a population-based case?control study. Additionally, the study aims to investigate the mode of interaction between body mass index (BMI) and physical workload (occupational kneeling/squatting and lifting/carrying of loads) with respect to the risk of symptomatic knee osteoarthritis. Methods In five orthopedic clinics and five practices, 295 male patients aged 25?70 with radiographically confirmed knee osteoarthritis associated with chronic complaints were recruited. The control group comprised 327 male control subjects. In a structured personal interview, body weight at different ages, body height, cumu...

2010-01-01

60

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

Energy Technology Data Exchange (ETDEWEB)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of {approximately}2E13cm{sup {minus}2}. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

1995-12-31

61

Boron enhanced diffusion due to high energy ion-implantation and its suppression by using RTA process  

International Nuclear Information System (INIS)

SIMS measurements revealed that high energy boron-implantation causes transient enhanced diffusion (TED) of a shallow dopant profile due to Si interstitials even for a relatively low dose of #approx#2E13cm"-"2. By systematic analysis, it is found that this anomalous diffusion is most significant in 700--800 C annealing, and it takes place in the initial stage (less than 30 sec for 800 C) of annealing. Moreover, this anomalous diffusion is more considerable than the enhanced diffusion during oxidation (OED) in practical device fabrication processes. It is found that rapid thermal annealing (RTA) at 1,000--1,100 C is effective for suppressing the transient enhanced diffusion and realizing a shallow channel profile for deep sub-micron devices.

62

Technological physics and special materials: wood-plastic composites obtained by radiation polymerization  

International Nuclear Information System (INIS)

General estimates and references are made in connection with the role of technological physics in obtaining materials with specific features. The first part of the paper presents the modification of weak wood essences as well as technological processes at bench-scale and semi industrial scale of wood-plastic composites, under various irradiation conditions. Two technological installations for the fabrication of wood-plastic composites on both scales with technical and practical specifications of their performances are presented. Experimental data for different wood-plastic composite systems using some local wood essences in combination with several polymer and copolymer systems are given. Impregnation and polymerization levels are mentioned for every specific system. The radiation dose rate and integrated dose are given for every experimental polymerization system. The features of the wood-plastic composites are compared ...

1995-12-02

63

Radiotherapy quality insurance by individualized in vivo dosimetry: state of the art; Dosimetrie individuelle in vivo pour le controle de qualite en radiotherapie: etat de l'art  

Energy Technology Data Exchange (ETDEWEB)

The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient tools for these controls. This paper ...

2009-06-15

64

Mining in the Alligator Rivers Region, northern Australia: Assessing potential and actual effects on ecosystem and human health  

International Nuclear Information System (INIS)

This paper presents an overview of issues related to surface water contamination arising from uranium mining activities in the Alligator Rivers Region (ARR) of northern Australia, and a program of research and monitoring that must assess the potential and actual effects on ecosystem and human health. The program of assessing effects on aquatic ecosystems involves a four-tiered approach including the derivation of local water quality guideline trigger values, direct toxicity assessment of mine waters prior to their release, creekside or in situ monitoring for early warning of adverse effects during mine water release, and longer-term monitoring of macroinvertebrate and fish communities. Bioaccumulation in aquatic biota is also assessed, and is an issue of importance not only to ecosystem health, but also to the health of local Aboriginal people. The aquatic animals they consume represent potential sources of radiological dose, and as a result, a major component of ...

2002-12-27

65

Irradiation of food  

International Nuclear Information System (INIS)

Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for ...

66

Development of detection methods for irradiated foods; development of immunological identification of irradiated foods  

Energy Technology Data Exchange (ETDEWEB)

Enzyme-linked Immunosorbent assay systems for the identification of irradiated egg, pork and chicken was developed. Eggs were irradiated in their shells to 0.5{approx}7kGy. Pork was irradiated to 0.5{approx}3kGy and chicken irradiated to 0.5kGy{approx}5kGy. The most sensitive proteins to irradiation were screened by SDS-PAGE and purified. Ovalbumin from egg, salt soluble protein(p) from pork, and salt soluble protein(c) from chicken showed the most sensitivity to irradiation. To investigate for a practical use in identifying of irradiated egg, pork and chicken, competitive ELISA was performed. The binding activity of ovalbumin to anti-ovalbumin IgG was reduced in a dose-dependent manner by irradiating up to 7kGy, and considerably lowered after irradiating at 7kGy. The concentration of 50% inhibition of ovalbumin to IgG was increased to 1.5(0.5kGy){approx}3.7(7kGy) times in an dose-dependent relationship. The binding ...

2002-04-01

67

Disposal of old heads for Daya Bay NPP  

International Nuclear Information System (INIS)

The paper introduces the disposal procedures of the old reactor pressure vessel head. Reactor pressure vessel (RPV) heads were replaced successfully in Daya Bay Nuclear Power Plant. The on-site treatment and disposal of replaced heads was thereafter implemented. This is the first time in China for large size radioactive article disposal. To guarantee the safety of old head treatment, issues of radiation protection have to be taken into account. Dose rate distribution of the old head surface and radioactivity were initially calculated according to the operation history and the neutron flux rate of the reactor. Shielding calculation and package design was thereafter worked out based on the data obtained from the old head, e.g. neutron flux, sorts of nuclides, radioactivity and dose rates. Shielding package was afterwards manufactured in special factories and transported to Daya Bay NPP site by truck and ship. The shielding package was designed ...

68

The preliminary success of ALARA implementation in Daya Bay NPP  

International Nuclear Information System (INIS)

Based on the practical condition of the plant and in reference to advanced management experiences worldwide, Daya Bay Nuclear Power Plant has established its own peculiar management system for radiation protection management and ALARA implementation. The characteristics of the system are: radiation protection training to all workers, active involvement of all managers and staffs, and whole process safety control to maintenance activities. The management philosophy of 'workers are responsible for their own radiation safety' is adopted in the plant. A strict, formalized and systematic whole staff radiation protection training, evaluation, authorization and periodically refreshing mechanism had been established and executed in the plant. In the organizational point of view, the responsibilities of line managers were specified in plant procedures, ALARA coordination organization on plant level and for specific activities were established. Meanwhile, the plant ...

2000-05-01

69

Development of methods of forecasting properties of polymer packaging materials which do not cause any changes in medicinal preparations during sterilization  

International Nuclear Information System (INIS)

The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physico-mechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl acrylate (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5 - 20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the polydispersity of ...

1974-12-09

70

Development of methods for forecasting properties of polymer packaging materials which do not cause any change in medicinal preparation during their sterilization  

International Nuclear Information System (INIS)

The authors present the results of an investigation of the effect of gamma radiation on the properties of low-molecular moulded polymethyl methacrylates (molecular weight distribution, physicomechanical properties, resistance to the effects of aqueous media and physiological solution) in the form of copolymers of methyl methacrylate with methyl (MA) or butyl acrylate (BA) with the brand names Dacryl-4B, Dacryl-2M and Dacryl-4M (4% BA; 2 and 4% MA respectively) having a molecular weight of around 10"5. For comparison, block polymethyl methacrylate with a molecular weight of 3 x 10"6 was used. The results of experiments on the ageing of unirradiated and irradiated specimens in a heated store-room (t = 10 - 20"0C) and at high temperatures (90"0C) are also given. It is shown that irradiation with doses of 2.5-20 Mrad leads to radiolysis of the above copolymers, accompanied by destructive processes. Evidence of this is an increase in the polydispersity of the materials ...

1975-01-01

71

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the gas ...

2006-07-01

72

Use of sting-response techniques for simulate diagnostics in human esophagus; Uso de tecnicas estimulo-respuesta para simular diagnosticos en esofago humano  

Energy Technology Data Exchange (ETDEWEB)

In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of ...

2003-07-01

73

Simulation for position determination of distal and proximal edges for SOBP irradiation in hadron therapy by using the maximum likelihood estimation method  

Energy Technology Data Exchange (ETDEWEB)

In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the ...

2005-12-21

74

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and exposure dose. Also noted ...

1985-01-01

76

Statistical modelling for social researchers principles and practice  

CERN Document Server

Statistical modelling for social researchers

2008-01-01

77

Evaluating Computer Capabilities in a Primary Care Practice-Based Research Network  

UK PubMed Central (United Kingdom)

PURPOSE We wanted to assess computer capabilities in a primary care practice-based research network and to understand how receptive the practices were to new ideas for automation of practice...Full Text Available

2004-09-01

81

Application of dose factors for decay chains  

International Nuclear Information System (INIS)

... dose rates inhalation iodine 134 krypton 88 nuclear decay quality factor

82

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage ...

2002-03-01

83

Rhipicephalus sanguineus: vector of a new spotted fever group rickettsia in the United States.  

Science.gov (United States)

A rickettsia related to but distinct from the spotted fever agent, Rickettsia rickettsii, has been detected in 167 (18.9%) of 884 Rhipicephalus sanguineus taken off dogs in central and northern Mississippi. The organisms could readily be isolated in male meadow voles (Microtus pennsylvanicus), where it produced massive infections in the tissues of tunica vaginalis. It was practically nonpathogenic for male guinea pigs, although inoculation of these animals with infected tunica vaginalis of voles afforded in 30 of 38 instances solid immunity to challenge with virulent R. rickettsii. The Rhipicephalus rickettsia grew well in monolayers of chicken embryo fibroblast, Vero, mouse L, and HeLa cells. Cytopathogenic effects were minimal unless large concentrations of rickettsiae were used as inocula. It also could be established in embryonated hen eggs but only after injection of massive doses of L cell-propagated organisms. Serological tests ...

1975-07-01

84

Remote tool applications at the FFTF [Fast Flux Test Facility] and the FFTF IEM [Interim Examination and Maintenance] Cell  

International Nuclear Information System (INIS)

Many types of maintenance activities are performed on contaminated (radioactive) machines and components at the Fast Flux Test Facility (FFTF). When personnel dose levels are within permissible limits, maintenance is performed in contaminated work areas or in gloveboxes. Otherwise, maintenance is performed in the Interim Examination and Maintenance (IEM) Cell, a hot cell that is used to perform tasks that require remote operation. Maintenance is often a combination of manual and remote operation. One such operation was the cleaning of the closed loop ex-vessel machine (CLEM) core component grapple (CCG). The CLEM is used to transfer core components in and out of the reactor vessel. The CCG had not been operating properly due to buildups of metallic sodium and sodium compounds on the outside surface and internal moving parts. This paper tells how the CCG was disassembled and cleaned. Part of this task was done in a glovebox and part in the IEM Cell. Therefore, ...

1990-11-11

85

Effect of processing on pirimiphos-methyl residues in stored peanuts  

International Nuclear Information System (INIS)

Peanut grains (1500g) were placed in a jute sack which was sprayed with "1"4C- pirimiphos-methyl [0-2-diethylamino-6-methylpyrimidin-4-yl-O, O-dimethylphosphorothiate, "1"4C-labelled in the 2-position of the pyrimidine ring]; total dose 5.55 MBq + 22.5 mg cold insecticide. As in practice, the sack was stored under local conditions for 36 weeks. The grain was crushed, dried at 50 deg. C for 2 hours and soxhlet extracted with chloroform-methanol (1:1). The crude oil was then subjected to sequential processes of alkali treatment, bleaching and deodorization. The initial residue concentration in the crude oil (5.66 ppm) was reduced to 4.50 ppm through alkali treatment and declined further to 3.78 ppm after bleaching. Deodorization removed a substantial amount of "1"4C-residues leaving 1.35 ppm in the refined oil. It may be concluded that simulated commercial processing of crude oil were capable of removing 76% of pirimiphos-methyl and/or products. ...

1995-08-01

86

Development of real time personal neutron dosimeter with two silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)

1997-07-01

87

Development of a process for the disposal of evaporation residues from NPP by precipitation/flocculation and solidification of the precipitation products. Final report  

International Nuclear Information System (INIS)

To reduce the volume of radioactive wastes after evaporation, activity carriers can be separated from the inactive salt load. Boric acid separation from PWR concentrates was considered a preliminary stage for nuclide precipitation. In connection with the precipitation process, the reaction conditions for boric acid separation were determined by bench-scale experiments. After evaluating the known purification processes, crystallization was suggested as a practicable method. After inactive bench-scale experiments, mixed crystal formation with iron hexacyanoferrate for Cs removal was chosen. The disturbing effect of the complexing agents was neutralized by a pre-dose of iron-III-salts. By specifying the precipitation conditions, for Cs-134 an activity separation from 3,0 E + 06 Bg/l to 1,9 E + 02 Bg/l, and for Cs-137 from 5,9 E + 06 Bg/l to 1,2 E + 02 Bg/l was achieved. Accordingly, the decontamination factor for Cs-134 was 16000, and for Cs-137 ...

88

Application and experience of low alloy steel main coolant lines in PWRs  

Energy Technology Data Exchange (ETDEWEB)

The significant technical and industrial aspects which have led to main coolant line (MCL) materials selection are addressed from a long term experience and operational practice point of view. They are based on the Siemens/KWU developed basic material concept for its nuclear power plants. It considers the choice of appropriate materials, the evaluation and qualification of the materials and the materials manufacturer, the use of appropriate semi-finished products, the tailoring of material and semi-finished products to the specific requirements of the various systems, the application of adequate manufacturing processes and the proof of the requirements by specifying proper tests and examinations. The main systems are assigned to safety classes in accordance with their safety relevance. Summarizing the operation time of nuclear power plants with ferritic MCL equipped by Siemens/KWU, more than 200 years of operation experience exist and no upgrading or replacement of ...

1996-08-01

89

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...

90

Oak Ridge Health Studies Phase 1 report, Volume 2: Part A, Dose Reconstruction Feasibility Study. Tasks 1 and 2, A summary of historical activities on the Oak Ridge Reservation with emphasis on information concerning off-site emissions of hazardous materials  

Energy Technology Data Exchange (ETDEWEB)

The Phase I feasibility study has focused on determining the availability of information for estimating exposures of the public to chemicals and radionuclides released as a result of historical operation of the facilities at the Oak Ridge Reservation (ORR). The estimation of such past exposures is frequently called dose reconstruction. The initial project tasks, Tasks 1 and 2 were designed to identify and collect information that documents the history of activities at the ORR that resulted in the release of contamination and to characterize the availability of data that could be used to estimate the magnitude of the contaminant releases or public exposures. A history of operations that are likely to have generated off-site releases has been documented as a result of Task 1 activities. The activities required to perform this task involved the extensive review of historical operation records and interviews with present and past employees as well as other ...

1993-09-01

91

Linking ab initio energetics to experiment: kinetic Monte Carlo simulation of transient enhanced diffusion of B in Si  

Energy Technology Data Exchange (ETDEWEB)

We have developed a kinetic Monte Carlo (kMC) simulator that links atomic migration and binding energies determined primarily from first principles calculations to macroscopic phenomena and laboratory time scales. Input for the kMC simulation is obtained from a combination of ab initio planewave pseudopotential calculations, molecular dynamics simulations, and experimental data. The simulator is validated against an extensive series of experimental studies of the diffusion of B spikes in self-implanted Si. The implant energy, dose, and dose rate, as well as the detailed thermal history of the sample, are included. Good agreement is obtained with the experimental data for temperatures between 750 and 950 C and times from 15 to 255 s. At 1050o C we predict too little diffusion after 105 s compared to experiment: apparently, some mechanism which is not adequately represented by our model becomes important at this temperature. Below 1050o C, the ...

1998-12-16

92

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute toxicity, four-week oral toxicity, rat hepato carcinogenesis and the anti oxidative defense system, were ...

1988-04-18

93

4-week oral toxicity study of a combination of eight chemicals in rats: comparison with the toxicity of the individual compounds.  

Science.gov (United States)

In a 4-wk oral toxicity study, 4-wk-old male and female Wistar rats were exposed to a combination of arbitrarily chosen chemicals comprising sodium metabisulphite, Mirex, Loperamide, metaldehyde, di-n-octyltin dichloride, stannous chloride, lysinoalanine and potassium nitrite. The dose levels used were based on the "no-observed-adverse-effect level" (NOAEL) and the "minimum-observed-adverse-effect level" (MOAEL) of the individual compounds obtained in similar studies with Wistar rats previously performed at TNO-CIVO, and comprised 0 (controls), 1/10 and 1/3 of the NOAEL, the NOAEL and the MOAEL. In comparison with the adverse effects of the individual compounds, both more severe and less severe adverse effects were observed at the MOAEL of the combined compounds, indicating interaction of effects at this exposure level. Slightly decreased haemoglobin content and slightly increased relative kidney weight were the only treatment-related adverse effects seen in the ...

1990-09-01

94

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting; Die Messung des Dosisflaechenproduktes in der diagnostischen Radiologie als Methode zur Ermittlung der Strahlenexposition. (Ergebnisse, Erfahrungen, Verbesserungsvorschlaege und Empfehlungen zum Strahlenschutz). Bericht ueber ein Expertentreffen  

Energy Technology Data Exchange (ETDEWEB)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product ...

1995-12-31

95

Method of describing dose distributions in computer design of teleradiotherapy  

International Nuclear Information System (INIS)

Method for description of X-ray radiation dose distribution based on semiempirical description of dose fields is suggested. At that dose field description parameters can be easily individualized for concrete X-ray device.

96

Determination of Organ Doses During Radiological Examinations and Calculation of Somatically Significant Dose.  

Science.gov (United States)

Examples are used to demonstrate that a shift in the point of emphasis is necessary with regard to radiation hazard in medicinal X-ray diagnosis. The parameters employed in this study to calculate somatic dose (SD) and somatically significant dose (SSD) m...

1980-01-01

97

Counselling in an inner city general practice: analysis of its use and uptake.  

UK PubMed Central (United Kingdom)

BACKGROUND. In recognition of the emotional problems which frequently underlie somatic complaints, practices increasingly offer counselling as part of their services to patients. In an inner city practice,...Full Text Available

1994-04-01

98

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

100

The malignancy significant dose from external beam radiotherapy  

International Nuclear Information System (INIS)

In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.

1987-01-01

101

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

102

Harnessing competence and confidence: Dimensions in education and development for advanced and consultant practice  

Energy Technology Data Exchange (ETDEWEB)

Consultant and advanced practice are relatively new concepts in radiography. There is evidence to show that as the career progression framework is being adopted the numbers of consultant and advanced practitioners in radiography are growing with the latter growing at a faster rate. The article considers the concept of advanced and consultant practice and the education requirements to support development. Preparation for an advanced practice role begins at the practitioner stage. Masters' level programmes are available to support the development of advanced practice. Education needs to be flexible as new advanced practice roles emerge. It is necessary to take practitioners beyond a defined modality to include leadership and people skills. These are essential for those aspiring to become consultants. Consultants require a high level of clinical knowledge for expert ...

2008-12-15

103

Firearm ownership and storage practices in Pennsylvania homes.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To determine the household prevalence of firearms in Pennsylvania, and describe the storage practices for these weapons. DESIGN: A statewide telephone survey of 3,620 Pennsylvania adults...Full Text Available

1996-12-01

104

Development of barcode system for internal dose monitoring  

International Nuclear Information System (INIS)

In Tarapur Atomic Power Station unit-3 and 4, which is 540 MWe pressurized heavy water reactor, tritium is produced in primary heat transport system and moderator system. Tritium is a major contributor to the internal dose. Internal dose contributes about 30% of the collective dose. Internal dose monitoring and its control are important to control the collective dose. Estimation of internal dose is done by analysis of bioassay samples of radiation workers. In a month, about 7000 bioassay samples are analysed for the internal dose assessment during normal operation, and about 12000 during the biennial shut down of the reactor. To enhance the sample preparation and counting performance, minimize the entry errors and reduce the processing time, barcode based label generation system was developed for the internal dose ...

2008-11-19

109

Safe operation of research reactors and critical assemblies code of practice and annexes  

CERN Document Server

Safe operation of research reactors and critical assemblies

1984-01-01

110

Radionuclide X-ray fluorescence analysis. 3: Examples of application in practice  

Science.gov (United States)

Examples are given of the applicability and importance of radionuclide fluorescence analysis as a

1973-01-01

111

Practical application of a simplified vitamin B_1_2 radioassay  

International Nuclear Information System (INIS)

... blood serum patients radioimmunoassay sampling tracer techniques isotope

112

Microsoft Word - Programme_APN_Meeting_2011  

Wastenet

40 Rice cultivation practices in Vietnam

114

Evidential and Practical Certainty  

Science.gov (United States)

... We assume that A is chosen so that the claim in question meets whatever are the conventional requirements for confidence in the context at hand. ...

2011-05-14

115

Dose planning and dose delivery in radiation therapy  

International Nuclear Information System (INIS)

A method has been developed for calibration of CT-numbers to volumetric electron density distributions using tissue substitutes of known elemental composition and experimentally determined electron density. This information have been used in a dose calculation method based on photon and electron interaction processes. The method utilizes a convolution integral between the photon fluence matrix and dose distribution kernels. Inhomogeneous media are accounted for using the theorems of Fano and O'Connor for scaling dose distribution kernels in proportion to electron density. For clinical application of a calculated dose plan, a method for prediction of accelerator output have been developed. The methods gives the number of monitor units that has to be given to obtain a certain absorbed dose to a point inside an irregular, inhomogeneous object. The method for verification of ...

2008-08-01

116

Effective dose equivalent concept in radiopharmaceutical dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

1981-06-01

117

Effective dose equivalent concept in radiopharmaceutical dosimetry  

International Nuclear Information System (INIS)

The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...

118

Absorbed dose and dose reduction in mammography  

International Nuclear Information System (INIS)

First, absorbed dose at entrance surface was measured in routine mammography. Secondly, a possibility of dose reduction after introduction of Fuji computed radiography (FCR) system was examined. In a total of 350 mammographic studies including craniocaudal and medilateral projections, average thickness of compressed breast was less than 4 cm and most frequently recorded absorbed dose was 0.2-0.3 cGy (200-300 mrad). Minimum dose to obtain clinically acceptable mammograms in FCR system was estimated by comparing image quality of routine versus reduced dose studies. It was concluded that absorbed dose could be reduced to 1/4 of routine dose without creating significant drawback in diagnosis. (author).

1986-01-01

119

Radiation epidemiological analysis of late effects of population exposure at northern part of east ural radioactive trace  

Energy Technology Data Exchange (ETDEWEB)

Population residing in the northern part of the Chelyabinsk oblast and the south eastern part of the Sverdlovsk oblast of Russia affected to accidental exposure since 1957. The territory (East Ural Radioactive Trace - EURT) was contaminated after explosion of container with highly radioactive wastes at the Mayak Production Association. Studies of health effects of exposure in the southern, head part of EURT are conducted in the Ural Research and Practical Center of Radiation Medicine (U.R.P.R.M.). In the 1990's U.R.P.C.R.M. formed a cohort of EURT within Chelyabinsk oblast (14,500 cases and 19,400 external controls). The cohort was followed in 1957-1987 and the results of the study are discussed by Crestinina et al. First results of study on exposure late health effects among rural population in the northern part of the EURT are presented in this paper. Firstly, or the period 1958-2000 a statistically significant increase in cancer mortality associated ...

2006-07-01

120

Contract pricing of electric and telephone service: Current practice and policy  

Energy Technology Data Exchange (ETDEWEB)

Due mainly to competitive pressures, the practice of offering electric and telephone service under contracts or special tariffs negotiated individually between a utility and its customers has increased in importance in recent years. Moreover, the practice is likely to become still more widespread in the future. This creates questions of public policy that are of interest to regulators and ratepayers alike such as how to supervise the practice, how to encourage utilities to compete while preventing cross-subsidization and anticompetitive behavior, and how the practice will ultimately affect utilities and ratepayers. This report sheds light on the topic by describing approaches that have been taken by the various regulatory commissions and by providing a framework for analyzing such contractors.

1992-04-01

121

Patient doses from medical uses of x-rays  

International Nuclear Information System (INIS)

A survey to determine the annual genetically significant dose and mean bone-marrow dose to the Australian population from radiological procedures has been undertaken. For diagnostic radiology the following were carried out: determination of the frequency of a procedure; measurement of patient doses using TLD and processing of data and calculation of gonadal and bone-marrow doses.

1981-01-01

122

Evaluation of transient dose in conveyor type low dose irradiator  

International Nuclear Information System (INIS)

In conveyor type irradiators, the movement of conveyor and the product boxes is not there until the source is fully in the irradiation position. In case the conveyor system fails the source must automatically be returned to its shielded storage vault. The dose received by the product during the movement of the source from or to the shield becomes significant if the total dose to be received by the product is small. A study has been carried out for evaluating the transient dose received by onions in the POTON irradiator. The results of the study are discussed in this paper. (author)

2003-03-05

123

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

124

X-ray dose enhancement effects  

International Nuclear Information System (INIS)

A brief description of the physical process of dose enhancement effects produced by X-ray radiation on materials is given, with emphasis on the influence on electronic devices. The damages caused by X-ray radiation dose enhancement is more serious than that of #gamma#-ray with higher energy.

125

Stochastic risk estimate for barium radiological examinations in Malaga (Spain)  

International Nuclear Information System (INIS)

The aim of this research work has been the estimation of the stochastic risk for five barium examinations. The sample was the population attending the Radiological Service of the 'Nuestra Senora de la Victoria' University Hospital, who had been treated with some barium examinations, set in five different groups: oesophagus tract, oesophagus-gastric-duodenal tract, intestinal tract, enteroclysis and double enema. To estimate the stochastic risk, it is necessary to know the organ dose. This can be calculated from the dose-area product which allows us to determine the effective dose using software. The dose-area product is the most suitable quantity to measure in these types of examination. We have evaluated the contribution that each procedure provides to the genetically significant dose, somatically significant dose, collective effective ...

2000-01-01

126

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

127

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a ...

2001-04-01

128

Induction of bladder cancer in rats by fractionated intravesicular doses of N-methyl-N-nitrosourea.  

UK PubMed Central (United Kingdom)

Experiments were conducted to determine the dose response of rat bladder urothelium to a range of different single and fractionated intravesicular doses of the carcinogen, N-methyl-N-nitrosourea (MNU)....Full Text Available

1982-03-01

129

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

130

Effects of small doses of ionizing radiation on human health  

Energy Technology Data Exchange (ETDEWEB)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-12-01

131

Effects of small doses of ionizing radiation on human health  

International Nuclear Information System (INIS)

The risks to human health from small doses of ionizing radiation raise questions which remain largely unanswered. This paper begins by explaining the historical background to this subject; it goes on to discuss recent developments and concludes with a personal view of the dose-reponse relationship. (author).

1997-01-01

132

Dose verification of helical tomotherapy intensity modulated radiation therapy planning using 2D-array ion chambers  

UK PubMed Central (United Kingdom)

Purpose:To investigate the clinical usage of dose verification of Helical Tomotherapy plans by using 2D-array ion chambers, and to develop an efficient way to validate the dose delivered...Full Text Available

133

A two-stage sequential linear programming approach to IMRT dose optimization  

UK PubMed Central (United Kingdom)

The conventional IMRT planning process involves two stages in which the first stage consists of fast but approximate idealized pencil beam dose calculations and dose optimization and the second...Full Text Available

2010-02-07

134

Radionuclide contents in food products from domestic and imported sources in Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Samples of some domestic and imported food products of nutritive importance to both the child population and the adult population in Nigeria were collected and analysed in order to determine their radionuclide contents. The samples were collected from open markets in major commercial cities in the country. Gamma-ray spectrometry was employed in the determination of the radionuclide contents in the products. The gamma-ray peaks observed with reliable regularity in all the samples analysed belong to naturally occurring radionuclides, namely {sup 226}Ra, {sup 228}Th and {sup 40}K. The activity concentrations of these radionuclides in both the domestic and imported products were observed to be not significantly different. Essentially radioactive elements such as {sup 137}Cs were not detected in any of the samples. The non-detection of {sup 137}Cs in the imported products may be attributed to the suitably modified agricultural practices and countermeasures being ...

2008-09-01

135

Radionuclide contents in food products from domestic and imported sources in Nigeria  

International Nuclear Information System (INIS)

Samples of some domestic and imported food products of nutritive importance to both the child population and the adult population in Nigeria were collected and analysed in order to determine their radionuclide contents. The samples were collected from open markets in major commercial cities in the country. Gamma-ray spectrometry was employed in the determination of the radionuclide contents in the products. The gamma-ray peaks observed with reliable regularity in all the samples analysed belong to naturally occurring radionuclides, namely "2"2"6Ra, "2"2"8Th and "4"0K. The activity concentrations of these radionuclides in both the domestic and imported products were observed to be not significantly different. Essentially radioactive elements such as "1"3"7Cs were not detected in any of the samples. The non-detection of "1"3"7Cs in the imported products may be attributed to the suitably modified agricultural practices and countermeasures being employed to reduce ...

2008-09-01

136

Protection provided by criminal law against hazards of nuclear energy and the harmful effects of ionizing radiation. Also a survey of the history of definition of offences against the atomic energy law and radiation protection law in the Federal Republic of Germany. Der strafrechtliche Schutz vor den Gefahren der Kernenergie und den schaedlichen Wirkungen ionisierender Strahlen. Zugleich eine Darstellung der historischen Entwicklung der Kernenergie- und Strahlendelikte in der Bundesrepublik Deutschland  

Energy Technology Data Exchange (ETDEWEB)

The subjects, principles and purpose of the atomic energy law and the radiation protection law are set out, and criminal offences under atomic energy law are outlined explaining the legal terminology applied. The peaceful uses of nuclear energy and radioactive materials are briefly discussed, primarily looking at the hazards involved and the protective role of criminal law principles that have been developed in connection with the atomic energy law and its application in practice. The draft version of the 16th criminal law amendment act - Act to combat environmental delinquency - is discussed, which aims at adoption of all criminal offences under atomic energy law by the Criminal Code. The book furthermore presents considerations about basic features of delinquency under atomic energy and radiation protection law, revealing elements and facts of offences defined, and particular problems resulting thereof. The question arises, e.g., whether an incorporation of the ...

1989-01-01

137

Monte Carlo simulation of electron cones used in electron beam therapy  

International Nuclear Information System (INIS)

A Siemens Mevatron KV2 accelerator installed at the Royal Adelaide Hospital employs cylindrical solid-walled electron cones for some electron collimation. The cones being used at present result in treatment fields that do not always conform with the International Electrotechnical Commission (IEC) Standards (particularly at high energies). The aim of this project was to simulate the existing cones using Monte Carlo methods in order to evaluate potential cone modifications required to overcome the field irregularities. Simulations were performed using the EGS4 (Electron Gamma Shower version 4, distribution II) Monte Carlo code installed on a DEC Alpha workstation at the University of South Australia. To rigorously simulate the existing electron cones it was necessary to also simulate various components within the treatment head of the linear accelerator. Results of simulations for existing cones were found to be consistent with experimental data. (obtained from Royal Adelaide Hospital ...

1998-09-01

138

Correlating microstructure and thermal transport of irradiated SiC  

International Nuclear Information System (INIS)

Full text of publication follows: The effect of neutron irradiation on the thermal conductivity of silicon carbide can be dramatic depending on the irradiation temperature and fluence the material is subjected to, and may be a critical factor defining it's use in fusion systems. Historically there have been several papers describing the effect of neutron irradiation on thermal conductivity degradation of SiC, predominately in the low to intermediate temperature ranges. Practically all of this work has been at temperatures lower than the application temperature for SiC being considered by the conceptual fusion reactors. This paper provides new data on the thermal conductivity of high quality CVD silicon carbide irradiated in a range of doses and temperature spanning the proposed fusion reactor temperature range. Specifically, an irradiation was carried out from fractions milli-dpa to approximately 8 dpa in the HFIR with irradiation temperatures ...

2007-12-10

139

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

140

On the Impact of Longitudinal Breathing Motion Randomness for Tomotherapy Delivery  

UK PubMed Central (United Kingdom)

The purpose of this study is to explain the unplanned longitudinal dose modulations that appear in helical tomotherapy (HT) dose distributions in the presence of irregular patient breathing....Full Text Available

2008-09-21

141

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) ...

2003-07-01

142

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

143

Using knowledge brokers to facilitate the uptake of pediatric measurement tools into clinical practice: a before-after intervention study  

UK PubMed Central (United Kingdom)

BackgroundThe use of measurement tools is an essential part of good evidence-based practice; however, physiotherapists (PTs) are not always confident when selecting, administering,...Full Text Available

144

Use of Read codes in diabetes management in a south London primary care group: implications for establishing disease registers  

UK PubMed Central (United Kingdom)

Objective To establish current practice in the use of Read codes for diabetes.Design Cross sectional study.Setting 17 practices in the Battersea...Full Text Available

2003-05-24

145

Substance use and dietary practices among students attending alternative high schools: results from a pilot study  

UK PubMed Central (United Kingdom)

BackgroundSubstance use and poor dietary practices are prevalent among adolescents. The purpose of this study was to examine frequency of substance use and associations between cigarette,...Full Text Available

146

Practice Leaders Programme: Entrusting and Enabling General Practitioners to Lead Change to Improve Patient Experience  

UK PubMed Central (United Kingdom)

This program focused on practice-level service change as a means of improving patient care and developing leadership skills of 19 general practitioners (GPs) and aimed to: promote and support change...Full Text Available

2011-01-01

147

Patient-reported-outcomes in subjects with painful lumbar or cervical radiculopathy treated with pregabalin: evidence from medical practice in primary care settings  

UK PubMed Central (United Kingdom)

The objective of this study was to evaluate the effect of pregabalin in painful cervical or lumbosacral radiculopathy treated in Primary Care settings under routine clinical practice. An observational,...Full Text Available

2010-06-01

148

Patient-Care Practices Associated With an Increased Prevalence Of Hepatitis C Virus Infection among Chronic Hemodialysis Patients  

UK PubMed Central (United Kingdom)

ObjectiveTo identify patient-care practices related to an increased prevalence of hepatitis C virus (HCV) infection among chronic hemodialysis patients.Full Text Available

2011-05-01

149

Malaria knowledge and agricultural practices that promote mosquito breeding in two rural farming communities in Oyo State, Nigeria  

UK PubMed Central (United Kingdom)

BackgroundAgricultural practices such as the use of irrigation during rice cultivation, the use of ponds for fish farming and the storage of water in tanks for livestock provide...Full Text Available

150

Influences on prescribing in non-fundholding general practices.  

UK PubMed Central (United Kingdom)

BACKGROUND: The experience from general practice fundholding suggests that financial incentives may influence prescribing; guidelines and hospital prescribing are two other suggested influences. AIM:...Full Text Available

1996-05-01

151

How can information extraction ease formalizing treatment processes in clinical practice guidelines? A method and its evaluation?  

UK PubMed Central (United Kingdom)

SummaryObjective:Formalizing clinical practice guidelines (CPGs) for a subsequent computer-supported processing is a challenging, but burdensome and...Full Text Available

2007-02-01

152

Determinants of output in group and solo medical practice.  

UK PubMed Central (United Kingdom)

Certain structural and environmental factors other than technical combination of resources and firm size are hypothesized to affect medical practice output. Four groups of variables related to physician...Full Text Available

1976-01-01

153

Data Quality of General Practice Electronic Health Records: The Impact of a Program of Assessments, Feedback, and Training  

UK PubMed Central (United Kingdom)

Objective: The aim of this study was to investigate the impact of a program of repeated assessments, feedback, and training on the quality of coded clinical data in general practice.Design:...Full Text Available

2004-01-01

154

Cultural beliefs that may discourage breastfeeding among Lebanese women: a qualitative analysis  

UK PubMed Central (United Kingdom)

BackgroundAlthough the health benefits of breastfeeding are well established, early introduction of formula remains a common practice. Cultural beliefs and practices can have an...Full Text Available

155

Council tax valuation band of patient residence and clinical contacts in a general practice  

UK PubMed Central (United Kingdom)

BackgroundThere is a dearth of data relating UK general practice workload to personal and social markers of individual patients.AimTo test whether there is a significant association...Full Text Available

2005-01-01

156

Cognitive performance in relapsing remitting multiple sclerosis: A longitudinal study in daily practice using a brief computerized cognitive battery  

UK PubMed Central (United Kingdom)

BackgroundThere is need for a cognitive test battery that can be easily used in clinical practice to detect or monitor cognitive performance in patients with multiple sclerosis (MS)....Full Text Available

157

COST ESTIMATING EQUATIONS FOR BEST MANAGEMENT PRACTICES (BMP)  

Science.gov (United States)

This paper describes the development of an interactive internet-based cost-estimating tool for commonly used urban storm runoff best management practices (BMP), including: retention and detention ponds, grassed swales, and constructed wetlands. The paper presents the cost data, c...

158

An Investigation of Nurses' Knowledge, Attitudes, and Practices Regarding Disinfection Procedures in Italy  

UK PubMed Central (United Kingdom)

BackgroundThis study assessed the level of knowledge, attitudes, and practice regarding disinfection procedures among nurses in Italian hospitals.MethodsA...Full Text Available

159

Access Intervention in an Integrated, Prepaid Group Practice: Effects on Primary Care Physician Productivity  

UK PubMed Central (United Kingdom)

ObjectiveTo estimate the joint effect of a multifaceted access intervention on primary care physician (PCP) productivity in a large, integrated prepaid group practice.Data...Full Text Available

2008-10-01

160

A Wireless Health Outcomes Monitoring System (WHOMS): development and field testing with cancer patients using mobile phones  

UK PubMed Central (United Kingdom)

BackgroundHealth-Related Quality of Life assessment is widely used in clinical research, but rarely in clinical practice. Barriers including practical difficulties administering...Full Text Available

162

National coordination of NPP operation: Belgian case  

International Nuclear Information System (INIS)

Adjusting generation to demand (load following) is compared with practical experience. The importance of pumped storage plants is emphasized.

1986-01-01

163

Joint Sensor: Security Test and Evaluation Embedded in a ...  

Science.gov (United States)

... from theory to practice will be significantly reduced while intrinsically revolutionizing the approach to engineering network security architectures. ...

2010-12-01

165

Hoh_Tribe_Timber, Fish and Wildlife Habitat Program  

Science.gov (United States)

This coverage describes forest practices and habitat conditions in the Hoh Usual and Accustomed Areas....

166

A Comparison of the Technical Communications Practices of ...  

Science.gov (United States)

... Scientists. NASA/DoD Aerospace Knowledge Diffusion Research Project. Descriptive Note : Technical memo. rept. no. 29,. ...

1994-12-01

167

Total dose hardening of SIMOX buried oxides for fully depleted devices in rad-tolerant applications  

International Nuclear Information System (INIS)

A total dose hardening treatment is applied to SIMOX buried oxides. Total ionizing dose radiation testing is performed on fully-depleted transistors fabricated on both hardened and non-hardened substrates. At 200 krads x-ray dose, the front gate shift is reduced from -0.7 to -0.2 V for FETs built on the hardened wafers.

1996-07-15

170

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

171

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

172

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

173

Software means of dose consumption planning  

International Nuclear Information System (INIS)

Russian 2009 p. 118 Ukraine Mazilov, AV Stadnik, IA NSC 'Kharkiv

2009-02-23

175

Infrared stimulated luminescence-decay shape from NaCl as a function of radiation doses  

Energy Technology Data Exchange (ETDEWEB)

Dose-dependent behavior of the infrared stimulated luminescence (IRSL) decay from NaCl has been studied experimentally using only one aliquot irradiated with a range of 2-200 Gy {beta}-radiation doses. It was observed that the maximum IRSL intensity has not changed by an increase in dose though the total intensity increased as expected. Considering the possible implications of our findings for dosimeter, the results were compared with the other studies and discussed.

2007-11-15

177

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

Energy Technology Data Exchange (ETDEWEB)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different.

1980-10-01

178

Estimation of organ dose during radiological and computer tomographic examinations with calculations of the somatically significant doses  

International Nuclear Information System (INIS)

The risks from radiation exposure during radiological diagnosis has usually been estimated in relation to genetic changes. Relevant information has been expressed as the genetically significant dose. In this paper we attempt to produce an analogous measure for evaluating the somatic risk in the form of a somatically significant dose index for radiological and CT examinations. It is shown that, for both types of examination, the two risk factors may be entirely different. (orig.).

1980-01-01

179

Effective dose equivalent in nuclear medicine investigations  

International Nuclear Information System (INIS)

... radiation hazards hazards health hazards MEDICINE. SOMATICALLY

1984-05-07

180

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

Energy Technology Data Exchange (ETDEWEB)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...

1993-05-01

181

Collective effective dose equivalent, population doses and risk estimates from occupational exposures in Japan  

International Nuclear Information System (INIS)

Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. ...

1993-01-01

184

Mammary carcinogenesis in the rat after low-dose irradiation  

International Nuclear Information System (INIS)

Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated ...

1992-07-12

185

Experience in implementing the idea of work management in radiation practices in Daya Bay NPP  

International Nuclear Information System (INIS)

The philosophy of work management in radiation protection puts emphasis on the following up and management of overall process from work selection, planning, preparation, implementation till experience feedback, and overall optimization of production and safety management. This paper reports practices and experiences of Daya Bay nuclear power plant in the implementation of the philosophy during operational radiation protection through the practical examples

2004-05-01

186

Australia 2020 Summit - Government Response - Strengthening communities, supporting families and social inclusion  

Wastenet

Government should model good practice in social inclusion and diversity.Apply a social inclusion test ...Government should model good practice in social inclusion and diversity.Apply a social inclusion test ...Government should model good practice in social inclusion and diversity.Apply a social inclusion test

187

Effect of dose on lead retention and distribution in suckling and adult female mice  

Energy Technology Data Exchange (ETDEWEB)

Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free /sup 203/Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age ...

1980-01-01

188

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

189

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to ...

2005-01-01

190

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the ...

2006-04-01

191

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

192

Radiation 2006. In association with the Polymer Division, Royal Australian Chemical Institute. Incorporating the 21st AINSE Radiation Chemistry Conference and the 18th Radiation Biology Conference, conference handbook  

International Nuclear Information System (INIS)

Full text: An adaptive response is a decreased biological effect induced by a priming radiation dose given prior to a challenge dose. Adaptive responses contradict the linear-nothreshold model of risk estimation. The pKZ1 mouse chromosomal inversion assay is an extremely sensitive assay for studying the mutagenic effect of low dose radiation. A non-linear dose response for chromosomal inversion has been observed in pKZ1 spleen and prostate after a single whole body irradiation with doses between 1?Gy and 10mGy. Doses between 5-10?Gy resulted in an induction in inversions and doses between 1-10mGy resulted in a reduction below endogenous inversion frequency. These results suggest that doses in the 1-10 mGy range cause host responses which overcompensate by not only preventing inversions that would normally occur as a ...

2006-04-01

193

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

194

From Egg to Crystal: A Practical on Purification, Characterization, and Crystallization of Lysozyme for Bachelor Students  

Science.gov (United States)

A practical hands-on course encompassing enzyme purification, biochemical characterization, and crystallization that completed the course work of 350 second-year bachelor students enrolled in molecular biology/biochemistry was given at the Universite Louis Pasteur of Strasbourg (France). The experimental part of the practical dealt entirely with the model protein lysozyme isolated from hen egg-white. It was designed as a research project to give students the possibility to practice biochemical methods such as chromatography, electrophoresis, and spectrophotometry. It also included enzyme activity assay and protein crystal growth that are usually taught in master-level courses. The organization of the practical work and the related experimental procedures are described and discussed.

2007-07-01

195

LLNL Site Specific ASCI Software Quality Engineering Recommended Practices Overview Version 1.0  

Energy Technology Data Exchange (ETDEWEB)

''The LLNL Site-Specific Advanced Simulation and Computing (ASCI) Software Quality Engineering Recommended Practices VI.I'' document describes a set of recommended software quality engineering (SQE) practices for ASCI code projects at Lawrence Livermore National Laboratory (LLNL). In this context, SQE is defined as the process of building quality into software products by applying the appropriate guiding principles and management practices. Continual code improvement and ongoing process improvement are expected benefits. Certain practices are recommended, although projects may select the specific activities they wish to improve, and the appropriate time lines for such actions. Additionally, projects can rely on the guidance of this document when generating ASCI Verification and Validation (VSrV) deliverables. ASCI program managers will gather information about their ...

2002-02-01

196

Promise and Possibility in Special Education Services for Students with Emotional or Behavioral Disorders: Peacock Hill Revisited  

Science.gov (United States)

This article provides an historical look at how programs and practices for students with emotional or behavior disorders (E/BD) have been evaluated since 1964, leading to a codified, although not universally recognized, set of recommendations for evaluating best practices for students with E/BD set out by The Peacock Hill Working Group (1991). The authors contend that, in addition to the programmatic features of best practice, the addition of the quality indicators and standards for research in special education add a critical dimension for examining the quality of the scientific research of identified best practices. Taken together, these set of recommendations and quality indicators represent the state of the art in program evaluation for best practice and programs for students with E/BD. The goal of this article is to outline the current recommendations and apply them to current ...

2010-08-01

197

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 ...

1991-01-01

198

The somatically significant dose, SSD, and analog of the GSD, the genetically significant dose  

International Nuclear Information System (INIS)

The medical applications of radiation comprise three main fields namely: Diagnostic Radiology, Radiotherapy and Nuclear Medicine. With the new weighting factors of ICRP (IC91a) the effective dose due to medical applications can be established. I is common to separate the effective dose into the genetic part and the somatic part, SED. In dealing with gonad doses it is important to account for the age of the person at the time of exposure as this will influence the number of children still to be expected from that person. The resulting dose will then be called the genetically significant dose, GSD. In a similar fashion this age factor will be important in considering the chance of tumor induction. The age of patients differs considerably from the average age of the general population. This age difference has to be accounted for if a comparison is to be made with other sources of ...

1991-11-01

199

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

Energy Technology Data Exchange (ETDEWEB)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...

2003-10-01

200

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

International Nuclear Information System (INIS)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance ...

2003-10-01

201

Medical irradiation and the use of the 'effective dose equivalent' concept  

International Nuclear Information System (INIS)

By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...

1980-03-01

202

Lung dose calculations at kilovoltage x-ray energies using a model-based treatment planning system  

International Nuclear Information System (INIS)

The determination of the dose to organs from diagnostic x rays has become important because of reports of radiation injury to patients from fluoroscopically guided interventional procedures. We have modified a convolution/superposition-based treatment planning system to compute the dose distribution for kilovoltage beams. We computed lung doses using this system and compared them to those calculated using the CDI3 organ dose calculation program. We also computed average lung doses from a simulated radiofrequency ablation procedure and compared our results to published doses for a similar procedure. Doses calculated using this system were an average of 20% lower for AP beams and 7% higher for PA beams than those obtained using CDI3. The ratio of the average dose to the lungs to the skin dose from the ...

2001-02-01

203

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT  

Energy Technology Data Exchange (ETDEWEB)

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle{sup 3}-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf ...

2006-02-07

204

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the ...

205

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

206

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

207

Influence of the X-ray radiation on the lifetime of carriers in the p-n junctions of Si and Ge  

International Nuclear Information System (INIS)

Lifetime of minority charae carriers in the Si and Ge p-n unctions has been measured by pulse method of conductivity modulation of base. Its dependence on the X-ray radiation dose has been investigated. Dependence of current transmission coefficients on the dose has been measured and their sharp decrease at low doses and the following saturation at high doses have been observed. Linear dependence of lifetime on X-ray radiation dose has been obtained. Resulting from the comparison of regularities of the change of lifetime due to current characteristics, it has been shown that X-ray radiation leads to the formation of the surface defects, influencing the change of current characteristics as well as to stationary structural defects, causing the decrease of lifetime of the charge carriers with the increase of X-ray radiation dose.

208

Dose enhancement in bone in electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

1984-05-01

209

Dose enhancement in bone in electron beam therapy  

International Nuclear Information System (INIS)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

210

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let ...

2006-07-01

211

The use of EPID-measured leaf sequence files for IMRT dose reconstruction in adaptive radiation therapy  

UK PubMed Central (United Kingdom)

For intensity modulated radiation treatment (IMRT) dose reconstruction, multileaf collimator (MLC) log files have been shown applicable for deriving delivered fluence maps. However, MLC log files are...Full Text Available

2008-11-01

212

The antihypertensive efficacy and tolerability of a low dose combination of ramipril and felodipine ER in mild to moderate essential hypertension.  

UK PubMed Central (United Kingdom)

1. The antihypertensive efficacy and tolerability of a low dose combination of the angiotensin converting enzyme inhibitor ramipril (2.5 mg) and the extended release formulation of the dihydropyridine...Full Text Available

1993-10-01

213

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator ...

1996-12-01

214

Somatic and genetic effects of small doses of ionizing radiations in man  

International Nuclear Information System (INIS)

Estimations on the somatic and genetic effects of small doses of ionizing radiations in Man have been proposed by the Advisory Committee on the Biological Effects of Ionizing Radiation, set up by the U.S. National Academy of Sciences. They have been published in an important report, issued in 1972, from which we briefly analyze here the Chapter dealing with the somatic effects. Small doses of raditions are expected to promote only carcinogenic effects. After a rapid survey of the human experience on which the estimations are based, as regards the latent period of cancers, the plateau region (period of high risk) and the absolute and relative risk expressed per rem, per 10"6 persons, per year, for leukaemia (having the highest risk) and for the ''other cancers''. These estimations were obtained by linear extrapolation to the 1 rem level from observations made after irradiation at relatively high dose levels and much higher ...

1976-01-01

215

Single-dose pharmacokinetics of ceftriaxone in healthy Chinese adults.  

UK PubMed Central (United Kingdom)

The pharmacokinetics of ceftriaxone were investigated in six healthy mainland Chinese adults (four males and two females). A single 1.0-g dose was administered intravenously or intramuscularly in a...Full Text Available

1985-02-01

216

Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries  

UK PubMed Central (United Kingdom)

Objectives To provide direct estimates of risk of cancer after protracted low doses of ionising radiation and to strengthen the scientific basis of radiation protection standards for environmental,...Full Text Available

2005-07-09

217

Results of single and repeat dose studies of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers  

UK PubMed Central (United Kingdom)

AimsTo assess the tolerability and pharmacokinetic profile of single and repeat doses of the oral matrix metalloproteinase inhibitor marimastat in healthy male volunteers.Full Text Available

1998-01-01

218

Radiation risks for medical applications  

International Nuclear Information System (INIS)

The achievements made in the field of radiation protection over the past 20 years are outlined. Risk analysis as applied to medicine is considered and genetic significant doses, genetic risks, somatic effective doses and somatic risks are discussed. (C.F.).

1980-05-31

219

Pneumocystis carinii pneumonia complicating low dose methotrexate treatment for rheumatoid arthritis.  

UK PubMed Central (United Kingdom)

Low dose methotrexate has been used effectively for various rheumatic and non-rheumatic diseases. Three cases of Pneumocystis carinii pneumonia occurring during treatment of rheumatoid arthritis with...Full Text Available

1991-03-01

220

Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms  

UK PubMed Central (United Kingdom)

BackgroundThe aim of this study was to compare and to validate different dose calculation algorithms for the use in radiation therapy of small lung lesions and to optimize the treatment...Full Text Available

221

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

222

Milk residues and performance of lactating dairy cows administered high doses of monensin  

UK PubMed Central (United Kingdom)

AbstractMilk residues and performance were evaluated in lactating cows that were fed up to 10 times the recommended dose of monensin. Following an acclimatization period of 14 d, during...Full Text Available

2005-07-01

223

Methodology used to compute maximum potential doses from ingestion of edible plants and wildlife found on the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and ...

1990-10-01

224

Method of risk estimates for genetic, leukemogenic and carcinogenic effects from medical and occupational exposures  

International Nuclear Information System (INIS)

For the risk estimate of fatal malignancies, an effective dose was proposed on the basis of the assumption that the risk should be equal whether the whole body irradiated uniformly or whether there is non-uniform irradiation. The effective dose was defined by the product of organ or tissue doses and a weighting factor representing the proportion of risk factor for a fatal malignancy resulting from organ or tissue irradiation to the total malignant factor. The risk of malignancies can be derived by multiplying the malignant significant factor by the product of the risk factor and the effective dose. For the genetic risk, a significant factor was a relative child expectancy and organ or tissue doses were gonad doses. And, for the leukemogenic risk, a significant factor was the leukemia significant factor and organ or tissue dose was mean bone ...

1980-01-01

225

Metabolism of iodomethane in the rat  

UK PubMed Central (United Kingdom)

1. The LD50 of iodomethane orally administered to rats is 76mg./kg. body wt. but repeated daily doses of 30–50mg./kg. body wt. are without effect. 2. Oral doses of iodomethane to...Full Text Available

1966-01-01

226

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient ...

1991-06-01

227

Low-Dose, Off-Label Drotrecogin Alfa (Xigris) In Severe Sepsis  

UK PubMed Central (United Kingdom)

Objective:In this article, we describe a successful low-dose, off-label usage of drotrecogin alfa (Xigris), given at 18 mcg/kg per hour, in a patient with severe sepsis who had an...Full Text Available

2008-08-01

228

Low dose subcutaneous adrenaline to prevent acute adverse reactions to antivenom serum in people bitten by snakes: randomised, placebo controlled trial  

UK PubMed Central (United Kingdom)

ObjectiveTo assess the efficacy and safety of low dose adrenaline injected subcutaneously to prevent acute adverse reactions to polyspecific antivenom serum in patients admitted...Full Text Available

1999-04-17

229

Long-term effects of inhaled uranyl nitrate in rats  

International Nuclear Information System (INIS)

Rats were exposed to aerosols of "2"3"3U and "2"3"2U nitrate in a study of the long-term biological effects. Preliminary radiation dose estimates show lung > skeleton > kidney in each dose group.

1977-05-01

230

Isochron measurements of naturally irradiated K-feldspar grains  

International Nuclear Information System (INIS)

The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated ...

2007-09-01

231

Inhibition of exercise-induced asthma by nifedipine: a dose-response study.  

UK PubMed Central (United Kingdom)

1. The effect of three single doses of nifedipine on exercise-induced asthma has been examined in 11 asthmatic subjects. 2. On four separate days patients undertook 6 min of exercise on a treadmill...Full Text Available

1987-10-01

232

Induction of tumors by screening mammography  

International Nuclear Information System (INIS)

Somatic radiation doses are recognized to be possible factors of carcinogenesis. In correctly performed mammography, however, even as screening test, the radiation dose does not reach such an order of magnitude that the benefit of the procedure as to prevention of breast cancer is called into question.

1983-01-01

233

Fluence-convolution broad-beam (FCBB) dose calculation  

International Nuclear Information System (INIS)

IMRT optimization requires a fast yet relatively accurate algorithm to calculate the iteration dose with small memory demand. In this paper, we present a dose calculation algorithm that approaches these goals. By decomposing the infinitesimal pencil beam (IPB) kernel into the central axis (CAX) component and lateral spread function (LSF) and taking the beam's eye view (BEV), we established a non-voxel and non-beamlet-based dose calculation formula. Both LSF and CAX are determined by a commissioning procedure using the collapsed-cone convolution/superposition (CCCS) method as the standard dose engine. The proposed dose calculation involves a 2D convolution of a fluence map with LSF followed by ray tracing based on the CAX lookup table with radiological distance and divergence correction, resulting in complexity of O(N"3) both spatially and temporally. This simple algorithm is orders ...

2010-12-07

234

Estimation of frequency, population doses and stochastic risks in brachytherapy in Japan, 1983  

International Nuclear Information System (INIS)

Based on the replies to a questionnaire distributed throughout Japan in 1983, genetically significant dose (GSD), per Caput mean bone marrow dose (CMD), leukemogenically significant dose (LSD), malignantly significant dose (MSD), and per Caput effective dose equivalent (EDE) from using small sealed radiation sources for radiotherapy were estimated. Annual frequencies of brachytherapy were estimated to be 2.6 x 10"3 for men and 36.3 x 10"3 for women, with a total of 38.9 x 10"3. The annual frequencies of using afterloading technique were 0.3 x 10"3 for men and 18.8 x 10"3 for women, with a total of 19.1 x 10"3. The annual population doses per person were 7.9 nGy for GSD, 118 #mu#Gy for CMD, 19.3 #mu#Gy for LSD, 172 #mu#Gy for MSD, and 428 #mu#Gy for EDE. The annual collective effective dose equivalent was estimated to be 5.13 x 10"4 man Sv. ...

1988-01-01

235

Epidemiological survey of the effects of low level radiation dose: a comparative assessment  

Energy Technology Data Exchange (ETDEWEB)

This volume presents the collations tables of a six volume comparative epidemiological survey of the effects of low level radiation dose. Data are collated for the effects observed in the following irradiated groups:- Preconception irradiation, intra-uterine irradiation, childhood irradiation, adult irradiation. (UK).

1993-10-01

236

Effective per-capita dose as a yardstick for medical radiation exposure of the population - a supplement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The genetically significant dose (GSD) is an index variable which exclusively allows to describe the genetic risk in the progeny of a population due to the application of ionizing radiation and radioactive substances in one part of this population. It may result in wrong interpretation of population exposure at increasing incidence of examinations in a population involving ionizing radiation and radioactive drugs at simultaneously increasing application of alternative methods in children and adolescents owing to the fact that it indicates a downward trend although somatic exposure of this population has increased. Therefore, it is recommended to state both the GSD and the level of somatic radiation exposure of the population taken from the individual sources for the comparison and assessment of radiation exposure from various sources in future. Although the somatically significant dose constitutes the suitable variable complementary to GSD in ...

1984-06-01

237

ESR dosimetry of irradiated chicken legs and chicken eggs  

Energy Technology Data Exchange (ETDEWEB)

Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new ...

1996-12-31

238

Developing and evaluating stereotactic lung RT trials: what we should know about the influence of inhomogeneity corrections on dose  

UK PubMed Central (United Kingdom)

PurposeTo investigate the influence of inhomogeneity corrections on stereotactic treatment plans for non-small cell lung cancer and determine the dose delivered to the PTV and OARs.Full Text Available

239

Delivered dose of renal replacement therapy and mortality in critically ill patients with acute kidney injury  

UK PubMed Central (United Kingdom)

IntroductionThe optimal dialysis dose for the treatment of acute kidney injury (AKI) is controversial. We sought to evaluate the relationship between renal replacement therapy (RRT)...Full Text Available

2009-01-01

240

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow ...

1980-10-31

241

An analytic representation of the radial distribution of dose from energetic heavy ions in water, Si, LiF, and NaI  

International Nuclear Information System (INIS)

An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.

1989-09-01

242

A technique for the fast calculation of three-dimensional photon dose distributions using the superposition model  

International Nuclear Information System (INIS)

Techniques for reducing computation time in 3D photon dose calculations are addressed with specific emphasis given to the convolution/superposition approach. A single polyenergetic superposition model calculating absorbed dose per incident photon fluence (Gy cm"2) was developed in terms of TERMA and a total energy deposition kernel (a total point spread function). A novel approach was devised for reducing calculation time. The method, named the CF method, was based on the use of a conventional, fast model (here a modified power-law method was used) for the generation of 3D dose distributions on a fine dose matrix. Superposition calculations were carried out on a coarse matrix and calculation speed was increased simply by reducing the number of calculations. A set of correction factors was derived on the coarse grid from the ratio of the dose values from superposition to those from ...

1997-08-01

243

A randomized-controlled trial of low-dose doxycycline for periodontitis in smokers  

UK PubMed Central (United Kingdom)

Background/AimTobacco use reduces the effect of non-surgical periodontal therapy. Host-modulation with low-dose doxycycline (LDD) might favour repair and promote...Full Text Available

2007-04-01

244

The circadian rhythm for the number and sensitivity of radiation-induced apoptosis in the crypts of mouse small intestine  

Energy Technology Data Exchange (ETDEWEB)

Survival curves were constructed from dose-incidence curves for apoptosis in the crypts of mouse small intestine, using the number of apoptotic cells after high doses (N{sub M}) as maximum cell population size. The mean lethal doses (D{sub 0}) for the dose range 0-0.5 Gy were calculated for each time of day. A circadian rhythm in both D{sub 0} and N{sub M} values was detected, indicating that both the number and sensitivity of radiation-induced apoptosis were changing throughout the day. (author).

1990-07-01

245

Study of dose variation in various body parts with respect to chest dose in the working environment  

International Nuclear Information System (INIS)

Mixed Uranium Plutonium Carbide ((U, Pu) C), in the form of pellets encapsulated in stainless steel tubes is the fuel for Fast Breeder Test Reactor (FBTR) at Kalpakkam. For the fabrication of fuel for enlarging the core of this reactor, high burn up plutonium is used. The external exposure in these labs was significantly higher than that with low burn up Pu fuel. Dose evaluation to the organs was carried out using experimental TLDs during various operations of FBTR fuel fabrication to study the dose distribution pattern. (author)

2011-02-22

246

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

247

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

248

Serum Creatine Phosphokinase Activity after Intramuscular ...  

Science.gov (United States)

... Title : Serum Creatine Phosphokinase Activity after Intramuscular Injection: The Effect of Dose, Concentration, and Volume. ...

1974-01-01

249

Retrospective Monte Carlo dose calculations with limited beam weight information  

International Nuclear Information System (INIS)

An important unresolved issue in outcomes analysis for lung complications is the effect of poor or completely lacking heterogeneity corrections in previously archived treatment plans. To estimate this effect, we developed a novel method based on Monte Carlo (MC) dose calculations which can be applied retrospectively to RTOG/AAPM-style archived treatment plans (ATP). We applied this method to 218 archived nonsmall cell lung cancer lung treatment plans that were originally calculated either without heterogeneity corrections or with primitive corrections. To retrospectively specify beam weights and wedges, beams were broken into Monte Carlo-generated beamlets, simulated using the VMC++ code, and mathematical optimization was used to match the archived water-based dose distributions. The derived beam weights (and any wedge effects) were then applied to Monte Carlo beamlets regenerated based on the patient computed tomography densities. Validation ...

2007-01-01

250

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

251

Patient doses in the Netherlands. [X-ray diagnosis and radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

Contributions to the population dose due to medical applications of ionising radiation are presented. It appears that contributions due to radiotherapy and X ray diagnosis are of comparable magnitude. To account for the age dependency of the radiation risks, contributions in terms of somatically significant dose equivalent are calculated as 0.3 mSv per caput per annum for X ray diagnosis and as 0.2 mSv per caput per annum for radiotherapy, the latter referring to only doses to organs outside the target volume. (author).

1991-01-01

252

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

253

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

254

New concepts in risk assessment for patients with radiological treatment  

International Nuclear Information System (INIS)

In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.

1986-01-01

255

Measuring relative probability of Am-242 #beta#-decay  

International Nuclear Information System (INIS)

... americium 241 americium 242 beta decay chain reactions integral doses mass

257

Incorporating an improved dose-calculation algorithm in conformal radiotherapy of lung cancer: re-evaluation of dose in normal lung tissue  

International Nuclear Information System (INIS)

Background and purpose: The low density of lung tissue causes a reduced attenuation of photons and an increased range of secondary electrons, which is inaccurately predicted by the algorithms incorporated in some commonly available treatment planning systems (TPSs). This study evaluates the differences in dose in normal lung tissue computed using a simple and a more correct algorithm. We also studied the consequences of these differences on the dose-effect relations for radiation-induced lung injury. Materials and methods: The treatment plans of 68 lung cancer patients initially produced in a TPS using a calculation model that incorporates the equivalent-pathlength (EPL) inhomogeneity-correction algorithm, were recalculated in a TPS with the convolution-superposition (CS) algorithm. The higher accuracy of the CS algorithm is well-established. Dose distributions in lung were compared using isodoses, ...

2003-10-01

258

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

260

CHAPTER 1 - NASA  

Science.gov (United States)

However, market based pricing doses not apply where the pricing .... the reimbursable work, market based pricing does not apply. 040202. ...

261

Algorithm for assessment of mean annual gonad dose and genetically significant dose from the data of personal dosimetry  

International Nuclear Information System (INIS)

During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).

1985-10-22

263

Practical measurement of diffusion constants in sintered zirconias by using a light-scattering method  

Energy Technology Data Exchange (ETDEWEB)

A practical method to determine the ionic diffusion coefficient and activation energy by using quasielastic light scattering (QELS) is presented. It is shown that a temperature dependence curve of the QELS intensity at a fixed frequency can be well fitted by Jonscher's formula and that the diffusion parameters can be obtained from this curve fitting. This method is successfully applied not only to crystals with high optical quality, as reported earlier, but also to opaque ceramics, which are more important than the crystals from a practical point of view. The composition dependence of the ionic diffusion coefficient is studied in sintered YbSZ to show the usefulness of this method.

1991-03-01

264

Mathematical programming and manufacturing management  

Energy Technology Data Exchange (ETDEWEB)

This talk will present an overview of the use of mathematical programming techniques in manufacturing management practice. The emphasis is on applied contributions in three areas: conceptual and qualitative results, modelling, and algorithms. The discussion will be limited to methods that have found or are likely to find application in practice. Overall the picture is not heartening and many promising directions have not resulted in practical applications. Yet there are several areas where significant opportunities exist, though they seem to be better for heuristics than for highly structured traditional models. Time will be available for discussion of topics that interest the participants.

1994-12-31

265

Mathematical Problem-Solving and Ontology: An Exercise  

British Library Electronic Table of Contents (United Kingdom)

In this paper the reader is asked to engage in some simple problem-solving in classical pure number theory and to then describe, on the basis of a series of questions, what it is like to solve the problems. In the recent philosophy of mind this ?what is it like? question is one way of signaling a turn to phenomenological description. The description of what it is like to solve the problems in this paper, it is argued, leads to several morals about the epistemology and ontology of classical pure mathematical practice. Instead of simply making philosophical judgments about the subject matter in advance, the exercise asks the reader to briefly engage in a mathematical practice and to then reflect on the practice.

2010-01-01

266

Distributed ontology building as practical work  

British Library Electronic Table of Contents (United Kingdom)

Ontologies ? a form of structured and logically related knowledge or classification hierarchy embedded in a computer system ? are regarded by many scientists as having enormous promise for the consistent use and re-use of data. To realise this promise, however, is not straightforward. In this paper, based on ethnographic observation, we argue that the challenges for ontology building are ?social? as much as they are technical. By this we mean the routine work undertaken in the building process and the problems and difficulties entailed can be understood in terms of the practices of knowledge workers and the practical nature of ?sorting things out?. Getting a better sense of how, in practise, this work gets done gives a sense of the main challenges of building successful ontologies and how ...

2011-01-01

267

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

268

Population exposure to external natural radiation background in the United States  

Energy Technology Data Exchange (ETDEWEB)

This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.

1981-04-01

269

Population doses from beam-therapy in Japan, 1978, 3  

International Nuclear Information System (INIS)

As a series of estimations of population doses and of risk estimates from medical exposures in Japan, the malignancy significant dose (MSD) and the fatal malignant risk from beam therapy were estimated based on a nationwide survey of radiotherapeutic treatments, using a malignancy significant factor and a weighting factor determined from the data on the cancer mortality among the atomic bomb survivors in Nagasaki. The effective dose was defined as a sum of the product of the weighting factor and the organ or tissue doses with respect to the malignant diseases. The organ or tissue doses were determined with ionization chambers placed at the positions of their center in a MixDp-phantom simulated lung tissues by a block of cork, using a telecobalt unit, a conventional X-ray unit and a medical linear accelerator. The organ or tissue doses were categorized into three ...

1981-01-01

270

Phase I Study of Conformal Radiotherapy and Concurrent Full-Dose Gemcitabine with Erlotinib for Unresected Pancreatic Cancer.  

Science.gov (United States)

PURPOSE: To determine the recommended dose of radiotherapy when combined with full-dose gemcitabine and erlotinib for unresected pancreas cancer. METHODS AND MATERIALS: Patients with unresected pancreatic cancer (Zubrod performance status 0-2) were eligible for the present study. Gemcitabine was given weekly for 7 weeks (1,000 mg/m(2)) with erlotinib daily for 8 weeks (100 mg). A final toxicity assessment was performed in Week 9. Radiotherapy (starting at 30 Gy in 2-Gy fractions, 5 d/wk) was given to the gross tumor plus a 1-cm margin starting with the first dose of gemcitabine. A standard 3 plus 3 dose escalation (an additional 4 Gy within 2 days for each dose level) was used, except for the starting dose level, which was scheduled to contain 6 patients. In general, Grade 3 or greater gastrointestinal toxicity was considered a dose-limiting ...

2011-05-01

271

Optimization of segment weight using simulated dynamics algorithm for beamlet-based IMRT  

International Nuclear Information System (INIS)

With accurate calculation algorithms in inverse planning for beamlet-based intensity modulated radiotherapy (IMRT), it takes time to calculate the dose matrix, which represents the dose distribution of each beamlet element to each voxel for unit fluence. To reduce the calculation time, coarse or approximate algorithms are often a choice, but this results in a final dose distribution that cannot reflect the real value. In addition, it is necessary to test if a coarse algorithm is capable of calculating the dose matrix of beamlets. In this work, simulated dynamics optimization algorithm was applied to optimize the segment weight to minish the dose error from the dose matrix calculation. After calculating the dose matrix by ray-tracing algorithm which takes into account just the primary component of absorbed dose, the ...

2007-08-01

272

Occupational exposure information system in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This paper introduces an occupational exposure information system in detail, which is developed and in operation presently by Daya Bay nuclear power plant. It is presented in the paper that individual dose monitoring items and method, design and classification of database configuration, statistics and analysis of individual dose, and management of staff entering and exiting controlled area. The system is instructive to analysing individual dose and optimizing radiation protection measures. (authors)

2005-07-01

273

Non-linearity of pre-dose response and its effects on TL dating  

Energy Technology Data Exchange (ETDEWEB)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-15

274

Non-linearity of pre-dose response and its effects on TL dating  

International Nuclear Information System (INIS)

Analytical expressions for thermoluminescence (TL) dating based on the modified Zimmerman model were derived. The non-linear behaviour of TL sensitivity is reexamined and is found to be due to electron capturing competitions in both test-dose excitation and the readout stages. A curve fitting method is proposed to determine the paleodose for the additive dose dating method. The multiple activation technique is also investigated, from which the paleodose should be regarded as an upper limit.

2009-03-01

275

Mechanism of radiation induced carcinogenesis: does a threshold exist?  

International Nuclear Information System (INIS)

Epidemiological studies will not solve the shape of the dose effect curve for stochastic effects in the low dose range. Unicellular processes are necessary for the primary processes so that no threshold dose exists. This is evident for somatic and genetic mutations. Not clearly solved is this question for the complex carcinogenesis. These processes develop with manifold interacting molecular and cellular steps. (orig.).

1996-10-23

276

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

277

Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography  

International Nuclear Information System (INIS)

The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.

1999-05-01

278

Development of a site-specific following accident dose assessment system  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project to interface the site-specific real-time radiological dose assessment system FADAS(Following Accident Dose Assessment System) to CARE. In this study, the results of the field tracer experiments conducted on the Younggwang site have been analysed. And the experimental procedure on Ulchin site has been introduced. The environmental characteristics on Ulchin and Wolsung has been investigated.

1997-12-15

279
280

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed ...

2004-12-01

281

27: Development of a convolution/superposition method for photon beams  

International Nuclear Information System (INIS)

The implementation of the convolution/superposition method in real dose planning situations is considered. The modelling of photon spectra, the use of patient and treatment setup information, and the calculation of the photon energy released in a patient are detailed. A comparison is made between the approaches of calculating the relative dose directly and using a factor derived from measurements to correct the calculated relative dose. 13 refs.; 7 figs.

282

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a ...

2004-12-01

283

WINPEPI updated: computer programs for epidemiologists, and their teaching potential  

UK PubMed Central (United Kingdom)

BackgroundThe WINPEPI computer programs for epidemiologists are designed for use in practice and research in the health field and as learning or teaching aids. The programs are free,...Full Text Available

284

Viewing the Constellations with Binoculars  

CERN Document Server

A guide to practical astronomy. It introduces the reader to some basic (and some not-so-basic) astronomical concepts, and discusses the stars and their evolution, the planets, nebulae, and distant galaxies

2010-01-01

285

Training the Force: Developing Financially Fit Service ...  

Science.gov (United States)

... 4. To measure my personal wealth by net worth, not income 5. To engage in sound budget, credit and tax management practices 6. ...

2011-05-13

286

Theoretical and practical considerations on the problem of metal--metal interaction.  

UK PubMed Central (United Kingdom)

The interaction between two metals, which can be either synergistic or antagonistic, implies that the behavior of one is changed by the presence of the other. Possible mechanisms of these interactions,...Full Text Available

1978-08-01

287

The informationist: building evidence for an emerging health profession*  

UK PubMed Central (United Kingdom)

Background:To encourage evidence-based practice, an Annals of Internal Medicine editorial called for a new professional on clinical teams: an informationist trained...Full Text Available

2010-04-01

288

The Changing Face of Urology in 2005  

UK PubMed Central (United Kingdom)

The practice of urology is changing, not only from a medical and technological standpoint, but also from a business standpoint. New and improved computer technology and enhanced databases have allowed...Full Text Available

2004-01-01

289

Terbuthylazine: Reregistration Eligibility Decision (RED)  

Science.gov (United States)

... practically non-toxic to birds. Exposure to birds can occur at ponds, aquaria, and waste water ponds. The typical exposure case ...

1999-03-18

290

Sugarcane Culture and Syrup Production.  

Science.gov (United States)

The publication gives the basic information needed by growers of syrup sugarcane. It includes descriptions of the sugarcane plant characteristics needed in syrup varieties, the best varieties, cultural requirements and practices, and the diseases and inse...

1988-01-01

291

Progress and Compliance in Alcohol Abuse Treatment*  

UK PubMed Central (United Kingdom)

Improving patient compliance with physicians’ treatment or prescription recommendations is an important goal in medical practice. We examine the relationship between treatment progress...Full Text Available

2010-03-01

292

Principles of antibody therapy.  

UK PubMed Central (United Kingdom)

The success of monoclonal antibodies in clinical practice is dependent on good design. Finding a suitable target is the most important part as other properties of the antibody can be altered by genetic...Full Text Available

1992-12-05

293

Plant intelligence  

UK PubMed Central (United Kingdom)

The concept of plant intelligence, as proposed by Anthony Trewavas, has raised considerable discussion. However, plant intelligence remains loosely defined; often it is either perceived as practically...Full Text Available

2009-05-01

294

Physician Coding and Reimbursement  

UK PubMed Central (United Kingdom)

Physician reimbursement and the coding to support it are critically important to the sustained health of any physician's practice. This article reviews the recent history of physician reimbursement...Full Text Available

2007-01-01

295

Open cholecystectomy. A contemporary analysis of 42,474 patients.  

UK PubMed Central (United Kingdom)

OBJECTIVE: This study evaluated, in a large, heterogeneous population, the outcome of open cholecystectomy as it is currently practiced. SUMMARY BACKGROUND AND DATA: Although cholecystectomy has been...Full Text Available

1993-08-01

296

Numerical Weather Prediction and Synoptic Meteorology.  

Science.gov (United States)

The report gives a summary of important developments in numerical weather prediction and discusses their relationship to, and effect on, the practice of synoptic meteorology.

1968-01-01

297

Meteorological effects of environmental controls.  

UK PubMed Central (United Kingdom)

The solution of the continuity equation in practical applications is examined, and the values needed for approximate solutions are indicated. Models are adequate for investigating what could happen,...Full Text Available

1975-04-01

298

Introducing the Systematic Approach to Training (SAT) as the international best practice in NPP personnel training: What is SAT, why it is used and for whom  

International Nuclear Information System (INIS)

Components of systematic approach to training its aims and methodology as well as issues of training organization are discussed.

1994-03-21

299

Hispanic Cultural Influences on Medical Practice  

UK PubMed Central (United Kingdom)

Because the proportion of Hispanic patients is increasing rapidly, most physicians are now coming into daily contact with Hispanics. In addition to obvious difficulty with oral communication, Hispanics...Full Text Available

1983-10-01

300

Experience of isolated sleep paralysis in clinical practice in Nigeria.  

UK PubMed Central (United Kingdom)

The supernatural fears associated with the experience of isolated sleep paralysis in the culture of developing countries is sometimes associated with the evolution of somatic symptoms of psychological...Full Text Available

1992-06-01

301

Distributed Computer Networks in Support of Complex Group Practices  

UK PubMed Central (United Kingdom)

The economics of medical computer networks are presented in context with the patient care and administrative goals of medical networks. Design alternatives and network topologies are discussed with...Full Text Available

1978-11-09

302

Dietary Restriction in Drosophila: Delayed Aging or Experimental Artefact?  

UK PubMed Central (United Kingdom)

Lifespan can be extended by reduction of dietary intake. This practice is referred to as dietary restriction (DR), and extension of lifespan by DR is evolutionarily conserved in taxonomically diverse...Full Text Available

2007-04-01

303

Convergent Flows: Humanities Scholars and Their Interactions with Electronic Texts  

Science.gov (United States)

This article reports research findings related to converging formats, media, practices, and ideas in the process of academics' interaction with electronic texts during a research project. The findings are part of the results of a study that explored interactions of scholars in literary and historical studies with electronic texts as primary materials. Electronic texts were perceived by the study participants as fluid entities because the electronic environment promotes seamless interactions with a variety of media and formats. Working with electronic texts combines some traditional information and research practices into new patterns of information behavior. The practice called "netchaining" combines aspects of networking with information-seeking practices to establish and shape online information chains, which link sources and people. Different forms of exploration of participants' research questions ...

2008-07-01

304

Combined Radiation and Thermal Injury after Nuclear Attack  

Science.gov (United States)

... Except for isolated radiation accidents over the ensuing years, little practical experience has been gained in the treatment of thermal injuries ...

2011-05-13

305

Best Practices: Better Support of Weapon System Program ...  

Science.gov (United States)

... acquisition process has produced weapons that are ... F/A-22 Raptor, Space-Based Infrared System ... occur because DOD's weapon programs do ...

2005-11-01

306

Barriers to Initiating Depression Treatment in Primary Care Practice  

UK PubMed Central (United Kingdom)

OBJECTIVE AND DESIGNThis study used qualitative and quantitative methods to examine the reasons primary care physicians and nurses offered for their inability to initiate guideline-concordant...Full Text Available

2002-02-01

307

BOOKMARKS:  

Wastenet

on practical projects such as woodland management, limestone grassland management, cattle management, conflict management and education. ...Cathy Heaton Telephone 01772 892400 Email cenquiries@uclan.ac.uk www.uclan.ac.uk/schoolbne

308

AN ANNOTATED BIBLIOGRAPHY OF ADULT LITERACY ...  

Science.gov (United States)

... Stone, CR & Grover, CC Practice Readers ... Tolbert, M., Withers, S. & Watkins, HT, Good Workers All State Department of Education, Columbia, South ...

1954-09-30

309

A practical microreactor for electrochemistry in flow  

UK PubMed Central (United Kingdom)

SummaryA microreactor for electrochemical synthesis has been designed and fabricated. It has been shown that different reactions can be carried out successfully using simple protocols.

310

A Novel Tool for the Assessment of Pain: Validation in Low Back Pain  

UK PubMed Central (United Kingdom)

BackgroundAdequate pain assessment is critical for evaluating the efficacy of analgesic treatment in clinical practice and during the development of new therapies. Yet the currently...Full Text Available

2009-04-01

311

 

UK PubMed Central (United Kingdom)

OBJECTIVE: To evaluate the effectiveness of a program to improve hypertension control practices in primary care. DESIGN: Retrospective quasi-experimental study. SETTING: Three hospital-based family...Full Text Available

1994-10-01

312

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels  

International Nuclear Information System (INIS)

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes ...

2005-02-21

313

Worker radiation doses in the United States at the dawn of the atomic era (1940--1960)  

Energy Technology Data Exchange (ETDEWEB)

Radiation doses to workers at the Manhattan Engineer District (MED) and US Atomic Energy Commission (AEC) sites due to external irradiation during 1940--1960 are reviewed. Categorized radiation dose data were available from AEC annual reports for some years. Annual individual radiation dose data for ten MED/AEC sites for all years were available from the US Department of Energy`s (DOE) Comprehensive Epidemiologic Data Resource (CEDR). These data are combined to produce an estimate of external collective dose equivalent to 172,000 person-rems (1720 person-Sv) for 1940--1960. During this period there were 41 overexposures, 19 criticality incidents, and 3 deaths due to acute radiation syndrome among several hundred thousand workers.

1994-06-01

314

The effective per caput dose equivalent as a measure of medical radiation exposure of the population - a complement or an alternative to the genetically significant dose  

International Nuclear Information System (INIS)

The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different ...

1984-01-01

315

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

316

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

317

Optimizing the conditioning regimen for allogeneic stem-cell transplantation in acute myeloid leukemia; dose intensity is still in need  

British Library Electronic Table of Contents (United Kingdom)

Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...

2011-01-01

318

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...

1996-12-31

319

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated ...

1996-11-10

320

On the applicability of the AAPM TG-60/TG-43 dose calculation formalism to intravascular line sources: Proposal for an adapted formalism  

International Nuclear Information System (INIS)

Despite the widely recognized usefulness of the AAPM TG-43 brachytherapy dose calculation formalism, a straightforward application of this approach to describe the dose distribution about intravascular line sources as proposed by TG-60 may be difficult or even impossible, especially when these line sources emit low-energy photons or beta particles. The causes of these limitations are investigated and illustrated by means of some numerical examples. In order to solve the observed limitations an adapted formalism is proposed, intended specifically for the description of the dose rate distribution about line sources but conceptually similar to the TG-43/TG-60 formalism. Several examples are presented to illustrate the usefulness of the proposed line source dose calculation formalism.

2001-04-01

321

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

322

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

323

Determination of radiation exposure and significance of its influential factors for X-rayed children in the GDR  

International Nuclear Information System (INIS)

After having discussed the peculiarities of children in X-ray diagnosis the application of the effective as well as the mean equivalent doses as to the determination of the radiation exposure in children is represented. In using computerized tomograms to determine position and extent of an organ the exposure by repeated X-raying was calculated referring to the entrance dose. Entrance dose measurements for all types of X-ray examination in hospitals and ascertainments of the frequency of radiograms in 20 X-ray departments were used to determine per capita and collective doses, resp., in several age groups. Alltogether, the per capita dose of children in the GDR amounts to 30% of that of adults. Conclusions were drawn as to taking measures to further reduction of radiation exposure: (1) Technical measures, such as positioning of patients, shielding of organs, quality assurance; (2) ...

1988-01-01

324

Comparative dosimetry for screen film systems and intensifier fluorography in urinary incontinence of women  

International Nuclear Information System (INIS)

In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.

1987-01-01

325

Very low-dose hyper-radiosensitivity: impact for radiotherapy of micrometastases; Hyperradiosensibilite aux tres faibles doses: impact en radiotherapie des micrometastases  

Energy Technology Data Exchange (ETDEWEB)

Radio-biologists have pointed out a novel radiobiological phenomenon observed in many tumor and normal cell lines: hyper-radiosensitivity to very low-dose (H.R.S.) followed by induced radioresistance (I.R.R.) after a threshold dose of 0.1-0.3 Gy that depends on the cell line. Radioresistance at high dose (i.e. higher than 0.5 Gy) and metastatic potential of tumor cells are likely major factors of failure in radiotherapy. A careful review of literature suggests that: 1) radiotherapy does not increase the metastatic potential of tumor cells; 2) radioresistance at high dose and metastatic potential are not related. However, inside a given tumor cell line, highly metastatic clones may elicit more cells showing H.R.S; or are more radiosensitive at high dose than poorly metastatic ones. Recent data obtained from molecular techniques (comet and immunofluorescence assays) applied to single ...

2007-09-15

326

Enjebi Island dose assessment  

Energy Technology Data Exchange (ETDEWEB)

We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and /sup 137/Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body ...

1987-07-01

327

Dose proportionality and the effect of food on vildagliptin, a novel dipeptidyl peptidase IV inhibitor, in healthy volunteers.  

Science.gov (United States)

Vildagliptin is a potent and selective dipeptidyl peptidase IV inhibitor in development for the treatment of type 2 diabetes that improves glycemic control by enhancing alpha- and beta-cell responsiveness to glucose. Two open-label, single-dose, randomized, crossover studies in healthy subjects (ages 18-45 years) investigated the dose proportionality of vildagliptin pharmacokinetics (n = 20) and the effect of food (n = 24) on vildagliptin pharmacokinetics. There was a linear relationship (r(2) = 0.999) between vildagliptin doses of 25, 50, 100, and 200 mg and area under the plasma concentration-time curve from time zero to infinity (AUC(0-infinity)) and maximum plasma concentration (C(max)). Dose proportionality was assessed using a statistical power model [X = alpha x (dose)(beta)]. The 90% confidence intervals of the proportionality coefficient, beta, for AUC(0-infinity) ...

2007-07-26

328

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

International Nuclear Information System (INIS)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences ...

2011-01-01

329

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two ...

2008-10-01

330

Estimation of population doses from medical uses of radiopharmaceuticals in Japan, 1977, 2  

International Nuclear Information System (INIS)

Population doses from diagnostic and therapeutic uses of radiopharmaceuticals have been estimated on the basis of a nation wide survey data on the number of investigations and treatments used radiopharmaceuticals in the nuclear medicine and the annual amount of their activities. The gonad and marrow doses were calculated from published biokinetics data from humans, employing the MIRD method. The resultant annual genetically significant dose from diagnostic and therapeutic uses of radiopharmaceuticals was 0.36 and 0.02 mrad (3.6 and 0.2 #mu#Gy) per person, respectively, with a total 0.38 mrad (3.8 #mu#Gy) per person. The annual per Caput mean bone marrow dose was 2.3 mrad (23 #mu#Gy) for diagnosis and 0.2 mrad (2 #mu#Gy), for therapy. The resultant annual leukemia significant dose was 1.8 mrad (18 #mu#Gy) per person for diagnostic uses and 0.2 mrad (2 #mu#Gy) per person for ...

1979-01-01

331

Development of a generic analysis code of dynamic compartment model for evaluation of doses in terrestrial biosphere  

International Nuclear Information System (INIS)

The release rate of a nuclide from a reactor or a radioactive waste disposal plant at the accident is not steady, but varies with time. The various parameters of a nuclide migration into environment vary also day after day, or with the seasons. In such cases, dynamic behavior of the nuclide in the environment must be taken into consideration. It is difficult for a mathematical model to involve all of mechanisms for the nuclide migration. The environment for evaluation of doses are usually divided into some of compartments in which a nuclide concentration is uniform. Time variations of the nuclide concentration in the compartment are described in simultaneous differential equations. The nuclide concentration can be solved as a time function, and the radiation doses, therefore, can be estimated as a time function. Generic analysis code for dynamic compartment model (GACOM) is developed for the nuclide migration and the evaluation of ...

1999-02-01

332

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, ...

1988-10-01

333

Calculating electron dose using a convolution/superposition method. 120  

International Nuclear Information System (INIS)

The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on paths from the interaction site to all the ...

334

AIDE: internal dosimetry software.  

Science.gov (United States)

AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides ...

2008-03-12

335

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

336

Is uniform target dose possible in IMRT plans in the head and neck?  

International Nuclear Information System (INIS)

Purpose: Various published reports involving intensity-modulated radiotherapy (IMRT) plans developed using automated optimization (inverse planning) have demonstrated highly conformal plans. These reported conformal IMRT plans involve significant target dose inhomogeneity, including both overdosage and underdosage within the target volume. In this study, we demonstrate the development of optimized beamlet IMRT plans that satisfy rigorous dose homogeneity requirements for all target volumes (e.g., #+-#5%), while also sparing the parotids and other normal structures. Methods and Materials: The treatment plans of 15 patients with oropharyngeal cancer who were previously treated with forward-planned multisegmental IMRT were planned again using an automated optimization system developed in-house. The optimization system allows for variable sized beamlets computed using a three-dimensional convolution/superposition dose ...

2002-04-01

337

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer ...

338

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means ...

2007-05-01

339

Retrospective individual dosimetry using luminescence and EPR after radiation accidents  

International Nuclear Information System (INIS)

In areas where radiation dose monitoring has not been performed, it is essential to use material available in the environment be able to rapidly assess doses to individuals for immediate emergency medical care or for general estimation of the radiological consequences. It was shown that certain types of telephone cards containing microchips have the potential to be used as individual radiation dosimeters in emergency situations to detect doses over 250 mGy by luminescence measurements. In order to understand the dosimetric properties of chip cards, the components obtained from INFINIEON Company at various stages of production were used for luminescence measurements. It is found that the protecting layer used above the chips so called 'globe top' is the main source of radiation induced signal in chip cards. The globe top produced by INFINIEON at that stage is found to contain SiO2 and Epoxy. In order to improve the ...

340

The Teaching Practices Observation Scale (TPOS): An Observational Taxonomy for Assessing Teacher-Preschooler Interactions during Free Play.  

Science.gov (United States)

This study examined preliminary psychometric properties of the Teaching Practices Observation Scale (TPOS), a newly developed observational taxonomy for assessing teacher behaviors during free play with young children. Behaviors of 42 child caregivers and junior kindergarten teachers were coded using a combination of time-sampling, event-sampling, and behavior ratings. Findings support the validity of observational coding scheme. (Author/KB)

1998-12-01

341

Quality assurance requirements for nuclear power plants in Hungary  

International Nuclear Information System (INIS)

In Hungary, legislation for nuclear power plants was developed at the end of the 1970s, among which is the quality assurance code for nuclear power plants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear power plant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.

342

Practice of radiation source control at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Daya Bay Nuclear Power Station has made a series of tries and efforts on radiation source control and benefited from them since it was put into commercial operation. Some of them were introduced from experience feedbacks of foreign nuclear power industry and others came from our own good practices

2004-05-01

343

Practical design methods for barrier pillars. Information circular/1995  

Energy Technology Data Exchange (ETDEWEB)

Effective barrier pillar design is essential for safe and productive underground coal mining. This U.S. Bureau of Mines report presents an overview of available barrier pillar design methodologies that incorporate sound engineering principles while remaining practical for everyday usage. Nomographs and examples are presented to assist in the determination of proper barrier pillar sizing. Additionally, performance evaluation techniques and criteria are included to assist in determining the effectiveness of selected barrier pillar configurations.

1995-11-01

344

Lessons learned from accidents investigations  

International Nuclear Information System (INIS)

Accidents from three main practices: medical applications, industrial radiography and industrial irradiators are used to illustrate some common causes of accidents and the main lessons to be learned. A brief description of some of these accidents is given. Lessons learned from the described accidents are approached by subjects covering: safety culture, quality assurance, human factors, good engineering practice, defence in depth, security of sources, safety assessment and monitoring and verification compliance. (author)

1997-10-26

345

Incorporating the e-HIM[R] Virtual Lab into the Health Information Administration Professional Practice Experience  

Science.gov (United States)

This article will highlight the experiences of two baccalaureate Health Information Administration (HIA) programs in the adoption of the American Health Information Management Association's (AHIMA) e-HIM Virtual Laboratory (Virtual Lab) into the Professional Practice Experience (PPE). Information is provided describing the implementation of the Virtual Lab, issues that were encountered, and subsequent feedback from students and faculty regarding this new technology.

2010-12-01

346

Environmental Review of Right-of-Way Clearing.  

Energy Technology Data Exchange (ETDEWEB)

This environmental review of right-of-way clearing for transmission projects has been undertaken by the Environmental Analysis Branch for the Division of Land Resources in BPA's Office of Engineering and Construction. It is intended to review the present practices and results of selective clearing, and to make recommendations toward improvements in environmental practices and procedures in mitigation development for impacts associated with right-of-way clearing. 29 figs.

1986-08-01

347

Energy saving technologies for protected horticulture - commercial demonstration and technology transfer  

Environmental Research Database

DescriptionFollowing publication of the Curry report, DEFRA have made a commitment to establish a number of pilot projects supporting a network of demonstration and development farms. These 'farms' are intended to support the process of technology transfer by giving free access to information on the practical application of new, emerging and best practice technologies. Protected Horticulture has been identified as a sub-sector requiring the establishment of one of these projects. One of the major pressures [continued...

2005-01-31

348

Collaborations in Mind, Brain, and Education: An Analysis of Researcher-Practitioner Partnerships in Three Elementary School Intervention Studies  

British Library Electronic Table of Contents (United Kingdom)

A reciprocal relationship informing both research and practice is one of the primary goals in the emerging field of Mind, Brain, and Education (MBE), yet the field has little documentation and analysis of such collaborations. In this article, we present case studies of three research-practice partnerships taking place between scientists and educators. By comparing and contrasting these three partnerships we expect to illuminate common characteristics, challenges, and benefits that come with doing MBE work.

2011-01-01

349

Anodic protection: theory and practice in the prevention of corrosion  

Energy Technology Data Exchange (ETDEWEB)

Theoretical and practical aspects of anodic protection for control of corrosion by a wide range of acidic and alkaline solutions are discussed. Chapters are included concerning strategic importance of metals and alloys in modern industry, applications to industrial equipment, descriptions of equipment used in the technique; design, operation and maintenance; economics, scientific principles, characteristics of potentiostats, laboratory tests and procedures, selected application examples and projected future uses. A section is devoted to electrochemical principles.

1981-01-01

350

Studies on inherited sterility induced in the progeny of gamma irradiated cotton leaf worm, Spodoptera littorals (Boisd.)  

International Nuclear Information System (INIS)

Full - grown pupae of the cotton leaf worm Spodoptera littorals (Boisd.) were gamma - irradiated with low doses of 25,50,75, or 100 Gy for male line and with 50 or 100 Gy for female line . The effects on reproduction, development and sex ratio were the biological aspects studied among P1,F1,F2 and F 3 generations . Also, the effects of dose accumulation applied grown male pupae through two or three filial generations and the retarded influence on their F1,F2,and F 3 progeny were examined. In another trial the histological examinations for ovaries and testes of irradiated parents and for their generation were made . The F1 males were more sterile than irradiated parental males while F1 females were more fertile than their irradiated parental females. Irradiation of P1 males did not clearly affect neither the percentage of mated females nor the average number of spermatophores per mated female among the individuals of P1,F1,F2 and F 3 ...

351

Radioiodine dosimetry and prediction of consequences of thyroid exposure of the Russian population following the Chernobyl accident  

International Nuclear Information System (INIS)

In the early period after the Chernobyl accident, analysis of patterns of "1"3"1I exposure of the human thyroid showed that contaminated milk was the basic source of "1"3"1I intake among the inhabitants of Russia. The equipment and techniques used for measurement of the "1"3"1I content in the thyroids of these individuals are described in this work. A model of the "1"3"1I intake, taking into account protective actions, and a method of thyroid dose calculation are discussed. The mean thyroid dose and frequency distributions of the thyroid doses to inhabitants of towns and villages of the Bryansk, Tula and Orel regions of Russia are presented. The mean dose to the thyroids of children living in the villages was 2 to 5 times higher than the dose to adult thyroids; for children living in the towns, the mean dose was 1.5 to 12 times higher. The mean thyroid mass in ...

352

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 8. Strahlendosen beim thorakoabdominalen babygramm und bei der abdomenaufnahme neugeborener und saeuglinge  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance ...

2010-06-15

353

Radiation exposure of children in pediatric radiology, Pt. 8. Radiation doses during thoracoabdominal babygram and abdominal X-ray examination of the newborn and young infants  

International Nuclear Information System (INIS)

Purpose: Reconstruction of radiation doses for the thoracoabdominal babygram and the abdomen X-ray from radiographic settings and exposure data acquired at Dr. von Hauner's Kinderspital (children's hospital of the University of Munich, DvHK) between 1976 and 2007; comparison of these dose values with values reported in the literature; recommendation of a reference dose value for the thoracoabdominal babygram. Materials and Methods: The data from all X-ray examinations performed since 1976 at DvHK were stored electronically in a database. After 30 years of data collection, the database now includes 305 107 radiological examinations (radiographs and fluoroscopies), especially 1493 thoracoabdominal babygrams and 3632 abdomen X-rays of newborns and young infants. With the computer program PAeDOS, a specific dose reconstruction algorithm was developed. Results: the entrance dose values ...

2010-06-01

354

Influence of dose calculation algorithms on isotoxic dose-escalation of non-small cell lung cancer radiotherapy  

International Nuclear Information System (INIS)

Background and purpose: A series of phase I/II clinical trials are being initiated in several UK centres to explore the use of dose-escalated schedules for the treatment of non-small cell lung cancer (NSCLC). Among them the IDEAL-CRT trial (ISRCTN12155469) will investigate the introduction of individualised 'isotoxic' treatment schedules based on the relative mean lung normalised total dose (rNTDmean), an estimator related to lung toxicity. Since treatment planning will be performed using different treatment planning systems (TPSs), for the quality assurance of the trial we have carried out work to quantify the influence of dose calculation algorithms based on the determination of rNTDmean and on the choice of individualised prescription doses. Material and methods: Twenty-five patient plans with stage I, II and III NSCLC were calculated, with the same prescription dose, using the ...

2010-12-01

355

Effective dose estimation in whole-body multislice CT in paediatric trauma patients  

Energy Technology Data Exchange (ETDEWEB)

The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective ...

2009-03-15

356

Effect of dose on lead retention and distribution in suckling and adult female mice  

International Nuclear Information System (INIS)

Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free "2"0"3Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. ...

357

Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada  

Energy Technology Data Exchange (ETDEWEB)

Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and red marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from ...

1994-06-01

358

Study of dose rates and radionuclides contributing to dose rates in India's 540 MWe pressurised heavy water reactors  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport system, Moderator systems, cover gas system and other ...

2006-11-13

359

Radiation induced micrencephaly in guinea pigs  

International Nuclear Information System (INIS)

A brain weight deficit of about 70 mg was induced at doses of approximately 75-mGy and a deficit of 60 mg was induced at 100 mGy. This confirms the effects projected and observed by Wanner and Edwards. Although the data do not demonstrate a clear dose-response relationship between the 75-mGy and 100-mGy groups, the data are statistically consistent with a dose-response effect because of the overlapping confidence intervals. The lack of a statistically significant observation is most likely related to the small difference in doses and the limited numbers of animals examined. There are several factors that can influence the brain weight of guinea pig pups, such as caging and housing conditions, the sex of the animal, and litter size. These should be taken into account for accurate analysis. Dam weight did not appear to have a significant effect. The confirmation of a micrencephalic effect induced x rays ...

2006-04-20

360

Preparation of polyester/gypsum/composite using gamma radiation, and its radiation stability  

Energy Technology Data Exchange (ETDEWEB)

Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation dose leads ...

2005-06-01

361

Pharmacokinetic and dosimetric characteristics of some thallium isotopes  

International Nuclear Information System (INIS)

Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the dose from lead-201 ...

362

High-dose neutron-irradiation effects in fcc metals at 4.6 K  

International Nuclear Information System (INIS)

The rate of residual-resistivity increase and the isochronal recovery have been studied on the fcc metals Al, Ni, Cu, Pd, Ag, Pt, and Au irradiated at 4.6 K with reactor neutrons to a dose of about 10"1"9 (fast neutrons)/cm"2. The rate of resistivity increase is nonlinear as a function of irradiation-induced resistivity; computer analysis shows that the data are best fitted with an erxpression having up to third-order terms in #DELTA#rho. There are deviations from simple damage-rate theory in all cases, but an anomalous negative deviation from a linear law (convex curvature) is observed in Ni, Pd, Pt (and Fe). This behavior is most probably caused by a decrease of the specific Frenkel-defect resistivity due to defect clustering, an effect which should contribute in all metals after fast-neutron irradiation to high doses. Saturation values of resistivity and defect concentration as well as recombination volumes have veen obtained more accurately ...

1977-12-01

363

Evaluation of the increase of superficial dose due to thermoplastic immobilizing in radiotherapy; Avaliacao dos efeitos de superficializacao de dose por imobilizadores termoplasticos em radioterapia  

Energy Technology Data Exchange (ETDEWEB)

Perforated thermoplastic masks are used to provide patients immobilization. This procedure inserts a material in the path of the radiation beam, that attenuates and modifies the beam fluence and flatness. The present study evaluates the increase in skin dose as a result of using thermoplastic masks. Relative doses were measured on the surface of a solid water phantom, in the presence and absence of masks. These masks were stretched according to deformation patterns observed in clinical routine. The measurements were obtained with a plane-parallel chamber (Markus type 23343) and radiochromic film (EBT Gafchromic) for 6MV X-rays from a linear accelerator, and for a radiation beam from a cobalt therapy unit. The results showed that thermoplastic masks, whose thickness varied between 2 and 3 mm, increased the dose on the surface by a factor of 3. Due to the variations in the skin dose distribution, clinical ...

2010-07-01

364

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we study the effect of the Ge{sup +} preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge{sup +} at 150 keV to doses ranging from 1x10{sup 15} to 8x10{sup 15} ions/cm{sup 2}. Boron was subsequently implanted at 3 keV with a dose of 1x10{sup 14} ions/cm{sup 2}. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show ...

2002-01-01

365

Effect of the Ge preamorphization dose on boron diffusion and defect evolution in silicon  

International Nuclear Information System (INIS)

In this paper, we study the effect of the Ge"+ preamorphization dose on boron diffusion and on the thermal evolution of end of range (EOR) defects during annealing. Amorphizations were carried out by implanting Ge"+ at 150 keV to doses ranging from 1x10"1"5 to 8x10"1"5 ions/cm"2. Boron was subsequently implanted at 3 keV with a dose of 1x10"1"4 ions/cm"2. Rapid thermal annealing (RTA) was performed for various time/temperature combinations in nitrogen ambient. Secondary ion mass spectroscopy (SIMS) and transmission electron microscopy (TEM) were used to study boron diffusion and defect evolution, respectively. We have found that after a given annealing, both the defect size and boron diffusivity are independent on the Ge ion dose. Increasing this dose only results in an increase of the defect density. These results are discussed and definitely show that EOR defects are involved in a ...

2002-01-01

366

Effect of energy and dose on transient-enhanced diffusion and defect microstructure in low energy high dose As{sup +} implanted Si  

Energy Technology Data Exchange (ETDEWEB)

(001) CZ silicon wafers were implanted with arsenic (As{sup +}) at energies of 10--50 keV to doses of 2 {times} 10{sup 14} to 5 {times} 10{sup 15}/cm{sup 2}. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including ...

1997-11-01

367

Effect of energy and dose on transient-enhanced diffusion and defect microstructure in low energy high dose As"+ implanted Si  

International Nuclear Information System (INIS)

(001) CZ silicon wafers were implanted with arsenic (As"+) at energies of 10--50 keV to doses of 2 x 10"1"4 to 5 x 10"1"5/cm"2. All implants were amorphizing in nature. The samples were annealed at 700 C for 16 hrs. The resultant defect microstructures were analyzed by XTEM and PTEM and the As profiles were analyzed by SIMS. The As profiles showed significantly enhanced diffusion in all of the annealed specimens. The diffusion enhancement was both energy and dose dependent. The lowest dose implant/annealed samples did not show As clustering which translated to a lack of defects at the projected range. At higher doses, however, projected range defects were clearly observed, presumably due to interstitials generated during As clustering. The extent of enhancement in diffusion and its relation to the defect microstructure is explained by a combination of factors including surface recombination of point ...

1996-12-02

368

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % ...

2005-11-23

369

Characterization of arsenic dose loss at the Si/SiO{sub 2} interface  

Energy Technology Data Exchange (ETDEWEB)

Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the dose loss is ...

2000-03-01

370

Characterization of arsenic dose loss at the Si/SiO_2 interface  

International Nuclear Information System (INIS)

Careful sample preparation and secondary ion mass spectroscopy have been used to characterize arsenic dose loss to the silicon-oxide interface. Using high resolution x-ray photoelectron spectroscopy for microprofiling, we have directly observed the pileup of arsenic at the silicon dioxide-silicon interface. At least half of the pileup is shown to be on the silicon side of the interface in the first monolayer of silicon. Monolayer chemical oxidation and etching are successfully used to profile this pileup in silicon. This pileup contains most of the arsenic dose loss that occurs during transient enhanced diffusion. This result is crucial to correctly model the dose loss and provides physical justification for using a trap/detrap model at the interface, which is necessary to account for the fact that the arsenic surface concentration remains constant during an anneal and the fact that the dose loss is ...

2000-03-01

371

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT ...

2010-10-01

372

AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source  

International Nuclear Information System (INIS)

We present a development of the use of the AAPM TG-43 dose formalism applied to "1"3"7Cs gynecological implant sources. The geometry factor, radial dose function, and anisotropy function of a "1"3"7Cs source modeled after the Nuclear Associates 67-809 series stainless steel jacketed tube source were derived following the AAPM TG-43 formalism. The dose rate distribution through the center of the source using the AAPM TG-43 dose formalism is calculated and compared with the calculations obtained using the Sievert summation and Monte Carlo simulation. The three methods resulted in an agreement within less than 5%, or an isodose rate line agreement within 2 mm. We demonstrate that the AAPM TG-43 formalism can be applied to "1"3"7Cs linear sources and is capable of serving as a "1"3"7Cs dose calculation algorithm that can be used for treatment planning purpose.

2004-04-01

373

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

374

A comparison study for dose calculation in radiation therapy: pencil beam Kernel based vs. Monte Carlo simulation vs. measurements  

International Nuclear Information System (INIS)

Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. ...

2002-10-20

375

[Single and 4-week oral toxicity studies of prulifloxacin (NM441) in aged dogs].  

Science.gov (United States)

Single-dose and repeated dose toxicity studies of prulifloxacin, a new antibacterial agent, were conducted in aged beagle dogs. I. A single-dose toxicity study Prulifloxacin was administered orally to aged female dogs at a single dose of 2500 and 5000 mg/kg. No death occurred in any group. Vomiting was observed in one of two animals at 2500 mg/kg and in both animals at 5000 mg/kg 3-4 hr after dosing. At 5000 mg/kg, vomiting was observed in both animals after feeding on the day after dosing. One animal also showed soft stool. Thereafter, no abnormalities were observed in any animal. No test article related changes were noted in food consumption, water consumption, body weight or pathological examination in any group. The results show that the lethal dose of prulifloxacin is judged to be greater than 5000 mg/kg in aged female dogs. II. A ...

1996-06-01

376

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

377

The application of Geant4 simulation code for brachytherapy treatment  

CERN Document Server

Brachytherapy is a radiotherapeutic modality that makes use of radionuclides to deliver a high radiation dose to a well-defined volume while sparing surrounding healthy structures. At the National Institute for Cancer Research of Genova a High Dose Rate remote afterloading system provides Ir(192) endocavitary brachytherapy treatments. We studied the possibility to use the Geant4 Monte Carlo simulation toolkit in brachytherapy for calculation of complex physical parameters, not directly available by experiment al measurements, used in treatment planning dose deposition models.

2000-01-01

378

Standard radiation monitoring at Sendai nuclear power station  

International Nuclear Information System (INIS)

Standard radiation monitoring has been conducted at Sendai nuclear power station for the purpose of estimation of 'source activity' during refueling outage and evaluation of countermeasures to reduce dose rate. Selected objects of the monitoring are radiation dose rate at maintenance area, radiation field at each equipment and piping, coolant chemistry and plant operation condition. Monitored data indicates that 'source activity' variation can be estimated to some extent using influential factors, and that evaluation of change of loose crud activity, which is presumed to be represented by the dose rate at letdown heat exchanger, is necessary to further explain change in radiation field at main work area. (author).

379

Radiation induced synthesis of low molecular weight of PTFE and their crosslinking in acetone medium  

International Nuclear Information System (INIS)

Polytetrafluoroethylene was obtained by radiation induced polymerization of tetrafluoroethylene in acetone at 195 K. An average diameter of the products was very small compared with commercial one; it was about 0.3 micro-meters. The yield was reached to 100% with a dose of 4 kGy. The crystallinity of the products is decreasing with increasing dose. The products become amorphous, for higher irradiation doses. It was found that PTFE obtained by irradiation of TFE in acetone at 195 K has branching structure. This was demonstrated by means of "1"9F MAS NMR. (Author)

2007-09-03

380

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

381

Radiation doses from flying through nuclear-debris clouds. Final report, 2-10 January 1985  

Energy Technology Data Exchange (ETDEWEB)

Taboada et al. have recently developed a computer model to predict gamma radiation doses to aircrews flying through nuclear-debris clouds. Although the model has the advantages of taking a large number of parameters into account and using the benchmark DELFIC code to model cloud dynamics, it takes up to 20 min for a single run on a mainframe computer. Results from a number of runs have been generalized into empirical formulae. From these results it is possible to estimate worst case gamma radiation doses for complex scenarios using a hand calculator.

1986-04-01

382

Mutual recombination and clusterization effect of the vacancy and interstitial barriers on radiation hardening materials  

British Library Electronic Table of Contents (United Kingdom)

There is proposed the nonlinear model of dose dependence saturation of the yield strength on the base of the vacancy and interstitial barrier interaction in this work. Processes of mutual recombination of vacancy and interstitial barriers and formation of vacancy and interstitial clusters are taken into consideration. In the framework of the model, the analytical equations corresponding to the evolution of the barrier densities and yield strength are obtained. It is shown that the yield strength of irradiated materials decreases with the increasing intensity of barrier recombination processes, the dependence being nonlinear. Also it is shown that the model is valid both for low doses and large doses on the stage of radiation hardening.

2009-01-01

383

Multicellular level dosimetry and low dose rate effects  

International Nuclear Information System (INIS)

Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.

1989-09-21

384

Induction of sterility in adults of Earias vittella Fabricius through late pupal irradiation  

International Nuclear Information System (INIS)

Studies on pupal irradiation of Earias vittella Fabricius, were undertaken to determine the optimum dose for sterile and competitive adults. Late pupae were irradiated with gamma radiation doses ranging from 150 to 300 Gy. Emerging adults were normal and without malformation. When males that emerged from irradiated pupae were crossed with normal female, fecundity as well as longevity was comparable to control, but there was drastic reduction in percent egg hatch in all the treatments. However, when females emerging from irradiated pupae were crossed with normal male, there was reduction in the fecundity as well as fertility and this effect was dose dependent. (author).

385

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

386

Accumulation and distribution of "8"5Kr in rats exposed to "8"5Kr atmospheres  

International Nuclear Information System (INIS)

Retention kinetics and tissue partition coefficients for "8"5Kr were determined in rats exposed to known concentrations of "8"5Kr gas. The tissue partition coefficients were used to calculate the relative tissue radiation dose, assuming exposure conditions equivalent to the maximum permissible concentration in air (MPC)a. The estimated radiation dose was highest in adrenals and body fat, about twice the dose estimated for the next highest tissue, ovaries. Saturation and desaturation curves show that the contents of the large intestines have a prolonged desaturation time compared to other samples analyzed.

1977-05-01

387

A dose computation algorithm used in MLC conformal treatment  

International Nuclear Information System (INIS)

A dose calculation algorithm for MLC based conformal radiotherapy is described in this paper. The algorithm is formulated by the coordinate of MLC leaves. Verification on the algorithm is made by comparing the dose distributions generated by this algorithm with that generated by a Differential Convolution Superposition algorithm for various regular and irregular fields. The results demonstrate that the present algorithm has suitable accuracy and high computational efficiency, thus it could be useful for the treatment planning process in MLC based conformal radiotherapy, where the workload for interactively or automatically designing the shapes of MLC is heavy. (authors)

2007-12-01

388

Collaborative and situated learning on the web ? how can teacher education theoretically and practically respond to changing demands and roles of teachers? : A Research based on case studies of online second language learning in ?communities of practice?  

DEFF Research Database (Denmark)

The background for this paper is a growing interest during the past decade in Denmark in the concepts of ?situated learning?, ?social theory of learning? and ?learning in communities of practice? developed by the American social anthropologist Jean Lave and the Californian Research Scientist Etienne Wenger. The work by Jean Lave from 1988 (Lave, 1988) based on anthropological field studies in Brazil and Liberia as well as later works by Lave & Wenger (Lave and Wenger, 1991; Chaiklin and Lave, 1993; Wenger, 1998; Wenger, McDermott, R. and W. Snyder, 2002) on situated learning and social learning theory have provoked considerable response in anthropological studies, in learning theories as well asin considerations about practical implementation of concepts like ?lifelong learning? in Denmark in recent decades. The European concept of ?lifelong learning? has had a big impact on educational thinking, including teacher education. In addition to ...

2006-01-01

389

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

390

Use of a convolution/superposition-based treatment planning system for dose calculations in the kilovoltage energy range  

International Nuclear Information System (INIS)

A number of procedures in diagnostic radiology and cardiology make use of long exposures to x-rays from fluoroscopy units. Although numerous studies have been performed to measure or calculate skin dose from these procedures, there have only been a handful of studies to determine the dose to the other organs. This thesis was focused on devising a method to calculate the absorbed dose to underlying tissues and organs. The work was performed in several stages. First, a commercial convolution/superposition-based treatment planning system used in radiation oncology was modified and complemented to make it usable with the low energies of x-rays used in diagnostic radiology. This required generation of energy deposition kernels in the kilovoltage energy range. The kernels were generated using the EGS4 Monte Carlo system of codes and added to the treatment planning system. The treatment planning system was then evaluated for its ...

2001-03-01

391

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...

2011-01-01

393

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

395

The cardiomyopathy associated with methylsalicylate  

UK PubMed Central (United Kingdom)

Dogs challenged with toxic doses of methylsalicylate developed acute myocardiopathy. Metabolic manifestations of uncoupling of oxidative phosphorylation by methylsalicylate (MS) were observed. Oxygen...Full Text Available

1975-05-01

396

The Importance of Health Physics and Medical Integration in ...  

Science.gov (United States)

Richard E. Toohey, PhD, CHP. " Dose Coefficients for Intakes of Radionuclides via Contaminated Wounds; Application of the. NCRP Wound Model ...

397

Tertiary-Butanol: A toxicological review  

British Library Electronic Table of Contents (United Kingdom)

Tert-Butanol is an important intermediate in industrial chemical synthesis, particularly of fuel oxygenates. Human exposure to tert-butanol may occur following fuel oxygenate metabolism or biodegradation. It is poorly absorbed through skin, but is rapidly absorbed upon inhalation or ingestion and distributed to tissues throughout the body. Elimination from blood is slower and the half-life increases with dose. It is largely metabolised by oxidation via 2-methyl-1,2-propanediol to 2-hydroxyisobutyrate, the dominant urinary metabolites. Conjugations also occur and acetone may be found in urine at high doses. The single-dose systemic toxicity of tert-butanol is low, but it is irritant to skin and eyes; high oral doses produce ataxia and hypoactivity and repeated exposure can induce dependence...

2010-01-01

398

Study of seasonwise variations in the environmental gamma dose rates in Tarapur emergency planning zone (EPZ)  

International Nuclear Information System (INIS)

During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)

2005-11-23

399

Strategy for population protection at the end of the emergency phase: the C.o.d.i.r.p.a. view; Strategie de protection des populations a l'issue de la phase d'urgence: reflexions du Codirpa  

Energy Technology Data Exchange (ETDEWEB)

In the case of a serious accident and as a precautionary measure, several protection actions can be implemented by the prefect during the emergency phase. In France the levels of intervention are given by a ministerial decree of the 13. october 2003, resuming recommendations of the International Atomic Energy Agency. The selected values are: an efficient dose of 10 mSv for the stake under cover and in the listening: the concerned persons have to put under cover in a building, any openings carefully closed and stay in the listening of the orders of the prefect; an efficient dose of 50 mSv for evacuation; an efficient dose to the thyroid of 100 mSv for the taking of stable iodine tablets. In order to help the authorities to choose between the keeping of populations at their place or immediate evacuation the decision criteria are: if the forecasted efficient dose of the first month is under 1 mSv, the ...

2008-07-15

400

Strategy for population protection at the end of the emergency phase: the C.o.d.i.r.p.a. view  

International Nuclear Information System (INIS)

In the case of a serious accident and as a precautionary measure, several protection actions can be implemented by the prefect during the emergency phase. In France the levels of intervention are given by a ministerial decree of the 13. october 2003, resuming recommendations of the International Atomic Energy Agency. The selected values are: an efficient dose of 10 mSv for the stake under cover and in the listening: the concerned persons have to put under cover in a building, any openings carefully closed and stay in the listening of the orders of the prefect; an efficient dose of 50 mSv for evacuation; an efficient dose to the thyroid of 100 mSv for the taking of stable iodine tablets. In order to help the authorities to choose between the keeping of populations at their place or immediate evacuation the decision criteria are: if the forecasted efficient dose of the first month is under 1 mSv, the ...

2008-07-01

401

Sterilization of male stray dogs with a single intratesticular injection of calcium chloride: a dose-dependent study  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveTo study a method of chemical sterilization and its efficacy in adult male stray dogs.MethodsSterilization was performed 45 days after a single bilateral intratesticular injection of calcium chloride (CaCl2) at the doses of 5, 10, 15 or 20 mg per testis per kg body weight.ResultsHistomorphological measures of testes showed total necrosis of testicular tissue at 45 days after an injection of either 10 or 15 or 20 mg CaCl2 along with fibrosis and hyalinization in seminiferous tubules and interstitial spaces. Infiltration of leucocytes was also observed with the 10- or 15-mg dose. Disintegration of germ cell arrangement in seminiferous tubules and washing out of germ cells from the tubules were noted with the 5-mg dose. Relative organ weight, epididymal sperm count, plasma and intrat...

2007-01-01

402

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is ...

1981-01-01

403

Radiation oxidation of phenol in petrochemical waste water. II  

International Nuclear Information System (INIS)

The rate was studied of radiation destruction of phenol aqueous solutions at a concentration range of 1 to 100 ppm. Irradiated were model solutions containing additions of some organic and inorganic substances typical of the petrochemical industry. In view of the fact that the radiation destruction kinetics is determined by the amount of dissolved oxygen in the sample and by the phenol concentration, relatively low doses were used. Thus, a sufficient amount of oxygen in the sample and therefore the oxidation mechanism of radiolysis were ensured. The dose-response relationships for phenol destruction were studied using doses of 50, 100, 200 and 400 J.kg"-"1; the limit dose was 500 J.kg"-"1. From the results obtained, a kinetic model was constructed of radiation phenol oxidation in aqueous solutions in the presence of various organic and inorganic additions. (B.S.).

1981-01-01

404

Procedure for radiation dose control in irradiated tissues during electron-beam therapy  

International Nuclear Information System (INIS)

The invention refers a procedure of radiation dose control in irradiated tissues during electron-beam therapy. It aims at meeting the planned radiation dose for diseased tissues and taking care of the healthy ones. Therefore, the dose distribution required is determined before irradiation in consideration of such factors as energy-dependence of detector sensitivity, self-absorption within the tissue, and relative biological effectiveness. Furthermore, the expected intensity distribution of secondary quantum radiation excited in the irradiated tissue is calculated. A radiation detector for local resolution is used for registration. During irradiation the calculated intensity distribution is compared with the measured one. The invention is applicable in radiation therapy with monoenergetic electron beams.

1984-11-08

405

Preparation of wood-polymer composites using radiation  

International Nuclear Information System (INIS)

Wood-polymer composites (WPC) have been prepared of pinewood with different monomers using Gamma radiation: acrylamide, butyl acrylate, butyl methacrylate, styrene, acrylonitrile, and polyester. The polymer loading was determined as a function of monomer concentration and absorbed dose. The data show that polymer loading increases by increasing the monomer concentration. In two cases, BMA and polyester, the polymer loading decreases at high concentrations. This can be explained by the increase of the viscosity. Thus the diffusion of the compound into bulk would be slower. The absorbed dose seems to play a positive role in enhancing the polymer loading by increasing the dose. The mechanical properties, tensile and compression strength, have been improved in the most cases for all monomer concentrations or absorbed doses. Using polyester there was no improvement in the mechanical properties, and using ...

1976-11-25

406

Prediction of drug particle size and content uniformity in low-dose solid dosage forms  

British Library Electronic Table of Contents (United Kingdom)

Drug particle size distribution has a profound impact to the content uniformity in low-dose solid drug products. We derived theoretically the skewness of potency distribution as a function of particle size distribution and target dose. It was demonstrated that both skewness and coefficient of variation diverge simultaneously with inverse square root of the target dose. This scaling relation was observed in recent experiment and was verified by Monte Carlo (MC) simulation, which was employed for the first time to solve for the full potency distribution from a random retrieving model. When tested against the criteria from USP uniformity of dosage units, MC simulation showed a striking anisotropic distribution of the data. This suggests a full-scale consideration of the potency distribu...

2010-01-01

407

Photoluminescence Decay of Irradiated Herbs  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt){sup -P}. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)

1999-07-01

408

Photoluminescence Decay of Irradiated Herbs  

International Nuclear Information System (INIS)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt)"-"P. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)

1998-07-05

409

Pharmacological optimization of tissue perfusion  

UK PubMed Central (United Kingdom)

After fluid resuscitation, vasoactive drug treatment represents the major cornerstone for correcting any major impairment of the circulation. However, debate still rages as to the choice of agent, dose,...Full Text Available

2009-07-01

410

Paediatric radiography - the avoidance of late radiation damage to the growing hip  

Energy Technology Data Exchange (ETDEWEB)

Epiphyseal plates of growing bones are sensitive to ionizing radiation and this poses problems for the paediatric radiotherapist. In this case report we describe a child in whom electron beam therapy to the groin delivered only low dose radiation to the proximal hip epiphyses - 130 cGy fractionated over 5 weeks - but who suffered late maldevelopment. We explore the success of various radiotherapy techniques in minimizing the dose to the hip epiphyses in four other children. The appropriate positioning of the limb, the choice of treatment modality and, where possible, individual shielding blocks are considered and their effect on the dose to the hip estimated. Absorbed doses of radiation delivered to the midpoint of the proximal femoral epiphyses have been retrospectively determined. (author).

1993-04-01

411

Optical dating: insufficiently bleached sediments  

International Nuclear Information System (INIS)

Although infrared-stimulated luminescence (IRSL) signals in feldspars can be bleached rapidly by sunlight, there could still be a small amount of IRSL signal remaining in sediment grains if they have experienced only relatively short sunlight exposure before deposition. This remaining signal results in a ''remnant dose'' stored in the grain and is important for young samples but negligible for old samples. Several methods have been introduced to detect insufficient bleaching, and some of them can provide information on the extent of the bleaching. Others can only distinguish between samples bleached for a very long time and for a short time. Empirical methods are introduced to evaluate the possible values of equivalent dose accumulated since the grains were deposited. These methods involve the analysis of the equivalent doses and the natural IRSL signals obtained using single-disc dose determination ...

1993-07-01

412

Optical and Structural Characteristics of Heavily Boron ...  

Science.gov (United States)

... Abstract : Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. ...

1988-05-24

414

Methylisothiazolinone contact allergy and dose-response relationships  

DEFF Research Database (Denmark)

Methylisothiazolinone (MI) used alone is a new preservative causing a high prevalence of contact allergy. The eliciting threshold of MI is unknown. The combination of MI and phenoxyethanol enhances the antimicrobial efficacy of MI.

2011-01-01

415
416

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with inverse attenuation correction, to yield an input fluence map. The ...

2002-08-01

417

High-dose insulin: A consecutive case series in toxin-induced cardiogenic shock  

British Library Electronic Table of Contents (United Kingdom)

Context. Cardiovascular medication overdoses can be difficult to treat. Various treatment modalities are currently recommended. Objective. To describe patient outcomes and adverse events of high-dose insulin therapy in consecutive overdose patients in cardiogenic shock after implementation of a high-dose insulin protocol (1-10 U/kg/h, while avoiding or tapering off vasopressors). Methods. This is an observational consecutive case series of patients identified from a registry. Data were collected by retrospective chart review of patients treated by our toxicology service with this protocol from February 2007 until March 2010. Results. Twelve patients were treated with high-dose insulin. The mean age was 36.5 years (SD 11.7). Seven patients had pre-existing vasopressor therapy, and all were ...

2011-01-01

418

Harmonized Tariff Schedule Codes Flagged with Prior Notice ...  

Science.gov (United States)

... 3004505040***, MEDICAMENTS, DOSED, VITAMINS, MULTIPLE, OTHER COMBINATIONS, FD3***. 3104100000**, CARNALLITE, SYLVITE AND OTHER CRUDE POTASSIUM SALTS, FD3**. ...

419

Focal fits during chlorambucil therapy  

UK PubMed Central (United Kingdom)

An elderly man receiving chlorambucil for chronic lymphatic leukaemia developed focal fits. The onset and frequency were dose related. There was no evidence of metabolic disturbance or of meningeal...Full Text Available

1979-11-01

420

Fluence- and exposure-to-dose conversion for human whole-body gamma irradiation  

International Nuclear Information System (INIS)

... kev range 10-100 kev range 100-1000 man mev range 01-10 personnel

1978-01-01

423

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

424

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

426

Effect of some chemicals on the radiation-induced lipid peroxidation  

International Nuclear Information System (INIS)

The effect of exposure to gamma rays on LPO contents in liver, spleen and kidney of mice and the anti-lipid-peroxidation of preparations of chinonin, tannic acid and squalene were reported. All these preparations were given by intragastric perfusion. For LPO, a modified method of TBA spectrophotometry was used for determination. The results show that LPO contents in tissues increased 72 h after whole-body exposure of mice to gamma rays, that in range of 0-4 Gy, there was a linear relationship between radiation doses and LPO contents, and that all three preparations were effective in reduction of the LPO content in liver, spleen and kidney of mice, with chinonin (at dose of 0.35 mg/mouse#centre dot#day) being more effective than tannic acid (at dose of 15 mg/mouse#centre dot#day) and squalene (at dose of 0.6 mg/mouse#centre dot#day).

427

Effect of gamma radiation on electrical and optical properties of (TeO_2)_0_._9 (In_2O_3)_0_._1 thin films  

International Nuclear Information System (INIS)

We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width ...

2011-02-01

428

EFFECT OF ANATOMIC MOTION ON PROTON THERAPY DOSE DISTRIBUTIONS IN PROSTATE CANCER TREATMENT  

UK PubMed Central (United Kingdom)

PurposeTo determine the dosimetric impact of inter-fraction anatomical movements in prostate cancer patients receiving proton therapy.Full Text Available

2007-02-01

429

Diffusion modeling of ion implanted boron in Si during RTA: Correlation of extended defect formation and annealing with the enhanced diffusion of boron  

International Nuclear Information System (INIS)

Accurate modeling of the enhanced diffusion of boron during rapid thermal annealing has been accomplished by incorporating the effects of extended defect formation and annealing on enhanced diffusion into a multizone, semiempirical model. The multizone model divides the implant profile into three zones defining regions of different defects and diffusion enhancements. The model also contains the initial enhanced diffusion and the transient diffusion effects associated with the dissolution of defect clusters and the annealing of extended defects, respectively. The saturation time for transient-enhanced diffusion contains an exponential function of implant dose in order to model the increase in point defect generated with higher implant dose. As a result, the model accurately simulates the boron diffusion profile over a wide range of implant doses and also shows the immobile boron peak of precipitated dopants produced during ...

431

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

432

Comparing dose calculation algorithms for an orthovoltage beam in a bone phantom  

International Nuclear Information System (INIS)

The aim of this work was to compare dose calculation algorithm results at orthovoltage energies for a phantom composed of a bone slab in water. The calculation methods investigated were: no correction, ETAR, Batho, convolution/superposition and Monte Carlo. All algorithms calculated depth dose curves in a water phantom within 4% of experiment. However in the bone phantom, differences of over 40% between the No Correction / ETAR / Batho / Convolution and Monte Carlo results in the 1 cm thick bone slab were observed. These differences are predominantly because the algorithms do not account for the differing atomic number of the bone compared to water The increased dose to bone and the tissue adjacent to the bone interface should be considered when treating with orthovoltage photons. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

1998-09-01

433

Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases  

International Nuclear Information System (INIS)

The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases originally calculated with pencil beam convolution (PBC) where large density inhomogeneities were present. Three other dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC), and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that, in terms of accuracy, the CCC algorithm performed better overall than AAA compared to VMC++, but AAA ...

2007-07-07

434

Collapsed cone and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical cases  

International Nuclear Information System (INIS)

The purpose of this work was to study and quantify the differences in dose distributions computed with some of the newest dose calculation algorithms available in commercial planning systems. The study was done for clinical cases where large density inhomogeneities were present. Three dose algorithms were used: a pencil beam like algorithm, the anisotropic analytic algorithm (AAA), a convolution superposition algorithm, collapsed cone convolution (CCC) and a Monte Carlo program, voxel Monte Carlo (VMC++). The dose calculation algorithms were compared under static field irradiations at 6 MV and 15 MV using multileaf collimators and hard wedges where necessary. Five clinical cases were studied: three lung and two breast cases. We found that the CCC algorithm performed overall better than AAA compared to VMC++, but AAA remains an attractive option for routine use in the clinic due to its short computation ...

2007-06-01

435

Challenges in conducting clinical trials in children: approaches for improving performance  

British Library Electronic Table of Contents (United Kingdom)

Recent legislative changes in both Europe and the USA have increased the responsibility of drug developers to purposefully study the agents they market in children so that specific dosing recommendations can be made to assist clinicians in their use. Typically, clinicians use empirical- or experiential-based rationales for selecting the dose to use in children, generally in a manner that attempts to achieve the same dose-exposure or pharmacokinetic profile in children as in adults. However, whether this approach achieves the necessary dose exposure or exposure effect needed may not be systematically explored during off-label use. This creates the opportunity for under- or over-exposure in children, particularly in very young children (i.e., less than 2 years old) where a combination of fac...

2009-01-01

436

Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization  

CERN Document Server

Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the ...

2005-01-01

437

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

438

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

439

Alpha-particle dose distribution effects at the cellular level  

International Nuclear Information System (INIS)

Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.

1985-02-01

440

Adducted proteins for identification of endogenous electrophiles.  

UK PubMed Central (United Kingdom)

Chemically reactive compounds in tissues can be monitored through their products of reaction with biomacromolecules. For the purpose of in vivo dose monitoring, hemoglobin (Hb) has been preferred to...Full Text Available

1993-03-01

441

Adaptive Management of Liver Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site....Full Text Available

2010-04-01

442

Absorption of plutonium in the iron-deficient rat  

International Nuclear Information System (INIS)

Iron deficiency did not enhance absorption of plutonium following intragastric gavage of rats. Absorption of plutonium citrate in both control and iron-deficient rats was about 0.03% of the administered dose.

1977-05-01

443

A computer program for rapid calculation of internal committed effective dose through inhalation and ingestion pathways under radiological emergency  

International Nuclear Information System (INIS)

Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)

2008-08-01

445

A Dose- and Time-Controllable Syngeneic Animal Model of Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

IntroductionThe development of novel diagnostic agents for the detection of breast cancer microcalcifications requires a reliable animal model. Based on previous...Full Text Available

2010-07-01

446

Servicing a world elsewhere? Examining everyday work practices in the emerging economic spaces of Malaysia's business process outsourcing industry  

British Library Electronic Table of Contents (United Kingdom)

The paper seeks to illuminate everyday work practices in the economic spaces of Malaysia's business process outsourcing (BPO) industry. It draws upon empirical evidence from call centre staff and promotes analytical sensitivity to the experience of labour and spatiotemporal relations within the offshore back offices of multinational corporations located in Cyberjaya, Malaysia. The analysis provides an empirical snapshot of how IT-facilitated work practices in the global information economy are embedded and socially reproduced in everyday settings. To this end, the paper engages anthropologically with BPO labour, and critiques -globalist- representations of economic and social transformation frequently articulated through an abstract, dehumanized space of networks and flows often seen to wa...

2011-01-01

447

Practices for caring in nursing: Brazilian research groups  

British Library Electronic Table of Contents (United Kingdom)

ERDMANN A.L., DE ANDRADE S.R., FERREIRA DE MELLO A.L., KLOCK P., DO NASCIMENTO K.C., SANTOS KOERICH M. & STEIN BACKES D. (2011) Practices for caring in nursing: Brazilian research groups. International Nursing Review58, 379-385 Background:- The present study considers the production of knowledge and the interactions in the environment of research and their relationships in the system of caring in nursing and health. Aim:- To elaborate a theoretical model of the organization of the practices used for caring, based on the experiences made by the research groups of administration and management in nursing, in Brazil. Methods:- The study is based on grounded theory. Twelve leaders of research groups, working as professors in public universities in the south and the south-east of Brazil, distri...

2011-01-01

448

Multiobjective design of Work-In-Process buffer for scheduling repetitive building projects  

British Library Electronic Table of Contents (United Kingdom)

Variability in production is one of the largest factors that negatively impacts construction project performance. A common construction practice to protect production systems from variability is the use of buffers (Bf). Construction practitioners and researchers have proposed buffering approaches for different production situations, but these approaches have faced practical limitations in their application. A multiobjective analytic model (MAM) is proposed to develop a graphical solution for the design of Work-In-Process (WIP) Bf in order to overcome these practical limitations to Bf application, being demonstrated through the scheduling of repetitive building projects. Multiobjective analytic modeling is based on Simulation?Optimization (SO) modeling and Pareto Fronts concepts. Simulation...

2009-01-01

449

Management of young onset colorectal cancer: divergent practice in the East of England  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aim- According to the revised Bethesda Guidelines, colorectal cancer (CRC) occurring under age 50-years should be screened to exclude Lynch syndrome. However, in current practice in East Anglia, tumour screening is initiated only after genetics referral, reserved for those with a strong pedigree. This study aimed to determine how many patients with young-onset CRC undergo tumour screening in hospitals in East Anglia. Method- A retrospective case notes review over 5-years in four hospitals was undertaken to determine what proportion of those with young-onset CRC underwent referral for tumour screening and to assess local practices in terms of patient counselling and management. Results- One hundred and twenty-two patients were included. There was an average yearly caseload of 6-9 p...

2011-01-01

450

Learning from a mouse - how adoption of Disney methods could assist development of CANDU control centres  

Energy Technology Data Exchange (ETDEWEB)

Many organizations are challenged with the tasks of identifying customer needs and expectations for their products, anticipating future product needs, communicating a future product vision to clients, and designing with today's technology to bring a future vision to successful realization. The design evolution of plant control centres is one aspect of CANDU development that faces such challenges. The Disney Corporation is an example of an organization that has been successful in consistently meeting these challenges for over fifty years; and some of the design practices proven in moviemaking, theme park and resort layout, and vacation experience organization may be helpful and effective when applied in other domains. This paper summarizes the findings from an examination of Disney Corporation design practices, and suggests how some practices could be used to simplify and enhance the design of future CANDU control ...

2005-07-01

451

Influence of gully erosion control on amphibian and reptile communities within riparian zones of channelized streams  

British Library Electronic Table of Contents (United Kingdom)

Riparian zones of streams in northwestern Mississippi have been impacted by agriculture, channelization, channel incision, and gully erosion. Riparian gully formation has resulted in the fragmentation of remnant riparian zones within agricultural watersheds. One widely used conservation practice for controlling gully erosion is the installation of drop pipes. This practice involves placing earthen dams across eroding gullies and embedding a metal standpipe within the dam to convey water from the field to stream level. Installation of this structure halts gully erosion and incidentally replaces eroding gullies with riparian habitats. Previous research evaluating gully erosion control structures have not considered the ecological impacts of these conservation practices on amphibian and repti...

2009-01-01

452

Improving osteoporosis care through multimodal interventions: insights from the University of Alabama at Birmingham Center for Education and Research on Therapeutics  

British Library Electronic Table of Contents (United Kingdom)

Despite the many advances in scientific research over the last several decades, cutting edge technologies and therapeutics often take many years to find their way into widespread use. The dissemination and uptake of best practices into clinical care is sometimes a neglected component of research that is essential to improve the population?s health. Type 2 translational research, sometimes called ?Proof in Practice Research,? seeks to maximize the yield of what has been learned from the bench and from carefully controlled clinical trials and to extend those benefits to a larger population. One aspect of type 2 translational research, sometimes called evidence implementation or implementation science, applies what has been learned about clinical medicine to achieve best practices across prov...

2011-01-01

453

Horticultural and Gathering Practices Complement Each Other: A Case Study in a Rural Population of Northwestern Patagonia  

British Library Electronic Table of Contents (United Kingdom)

We investigated gathering and cultivating practices and how they complement each other in a rural population of Northwestern Patagonia. We analyzed plant diversity, species similarity, biogeographic origin, and plant use by means of semi-structured interviews and field visits. Pichi Leufu inhabitants used 173 species: 138 cultivated plants, mainly for edible purposes, and 45 wild species principally for medicinal use. Most cultivated species were exotic (91.3%), whereas gathered plants were both native and exotic. While locals maintained vegetable gardens, the adoption of greenhouses improved conditions for certain crops. The integration of novel practices with ancestral knowledge suggests resilient processes in this community, probably reflected in the dynamics of current horticultural an...

2011-01-01

454

Energy policies in French municipalities. Examples of best practice  

Energy Technology Data Exchange (ETDEWEB)

The French agency of environment and energy mastery (Ademe) and Deutsche Energie Agentur (DENA) organised in Berlin on November 22 and 23, 2001, the first seminar and forum of ideas and exchanges on the implementation of energy efficiency and renewable energy policies in France and in Germany. On this occasion, Ademe asked Energie-Cites - an association of European cities with a long practical experience in 'good practice' exchanges - to prepare a publication describing the experience of about ten French cities or local energy agencies in energy management issues. The case studies presented in this document concern the following cities: Besancon, Dole, Dunkerque, Lille, Montpellier, and the local energy agencies of Clermont-Ferrand (Aduhme), Grenoble, Montreuil-Vincennes, Mulhouse and Rennes. (J.S.)

2001-11-01

455

DOE explosives safety manual  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) policy requires that all DOE activities be conducted in a manner that protects the safety of the public and provides a safe and healthful workplace for employees. DOE has also prescribed that all personnel be protected in any explosives operation undertaken. The level of safety provided shall be at least equivalent to that of the best industrial practice. The risk of death or serious injury shall be limited to the lowest practicable minimum. DOE and contractors shall continually review their explosives operations with the aim of achieving further refinements and improvements in safety practices and protective features. This manual describes the Department's explosive safety requirements applicable to operations involving the development, testing, handling, and processing of explosives or assemblies containing explosives. It is intended to reflect the state-of-the-art in explosives ...

1991-10-01

456

Beneficial management practices and mitigation of greenhouse gas emissions in the agriculture of the Canadian Prairie: a review  

British Library Electronic Table of Contents (United Kingdom)

Climate change is one of the main global issues of modern time. Ever increasing demand for food/feed and the need for higher environmental standards require shaping of the agricultural activities toward ecological and more sustainable efficient systems. One of the principal ways of attaining higher productivity and environmental standards is identification and adoption of beneficial management practices (BMP) by reviewing the conventional agricultural activities. The BMP are agricultural practices that promote sustainable land stewardship and maintain/increase profitability of farms. The BMP are from both crop and animal production systems and tradeoffs between the two systems could provide several opportunities in reducing, removing and/or avoiding of greenhouse gases (GHG) emissions. Des...

2011-01-01

457

Advancing High-Quality Literacy Research in Juvenile Justice: Methodological and Practical Considerations  

Science.gov (United States)

Special education researchers have made noteworthy progress toward conceptualizing literacy research questions, designing quality studies, and disseminating the results of their research. These advancements have been made through the establishment and refinement of quality research indicators. Unfortunately, this progress has mostly eluded the arena of juvenile justice special education research. The purpose of this article is to review juvenile justice literacy studies and provide juvenile justice personnel and researchers with methodological and practical considerations for improving the quality of juvenile justice literacy research. The focus is on advancing group designs. Practical concerns are based on the first-year experiences of researchers who implemented an Institute of Education Sciences Goal 3 study with the aim of determining the efficacy of literacy instructional programs in a juvenile justice setting.

2010-11-01

458

COMPARISON OF NATURAL BACKGROUND DOSE RATES FOR RESIDENTS OF THE AMARGOSA VALLEY, NV, TO THOSE IN LEADVILLE, CO, AND THE STATES OF COLORADO AND NEVADA  

Energy Technology Data Exchange (ETDEWEB)

In the latter half of 2005, the U.S. Environmental Protection Agency (USEPA) published a Proposed Rule (40 CFR Part 197) for establishing a dose rate standard for limiting radionuclide releases from the proposed Yucca Mountain high-level radioactive waste repository during the time period from 10{sup 4} to 10{sup 6} years after closure. The proposed standard was based on the difference in the estimated total dose rate from natural background in the Amargosa Valley and the ''average annual background radiation'' for the State of Colorado. As defined by the USEPA, ''natural background radiation consists of external exposures from cosmic and terrestrial sources, and internal exposures from indoor exposures to naturally-occurring radon''. On the basis of its assessments, the USEPA estimated that the difference in the dose rate in the two identified areas ...

2006-02-24

459

Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations  

International Nuclear Information System (INIS)

The accuracy of dose computation within the lungs depends strongly on the performance of the calculation algorithm in regions of electronic disequilibrium that arise near tissue inhomogeneities with large density variations. There is a lack of data evaluating the performance of highly developed analytical dose calculation algorithms compared to Monte Carlo computations in a clinical setting. We compared full Monte Carlo calculations (performed by our Monte Carlo dose engine MCDE) with two different commercial convolution/superposition (CS) implementations (Pinnacle-CS and Helax-TMS's collapsed cone model Helax-CC) and one pencil beam algorithm (Helax-TMS's pencil beam model Helax-PB) for 10 intensity modulated radiation therapy (IMRT) lung cancer patients. Treatment plans were created for two photon beam qualities (6 and 18 MV). For each dose calculation algorithm, patient, and beam quality, the ...

2006-09-01

460

planet BAN KI-MOON  

Wastenet

CLIMATE CHANGE Copenhagen: seal the deal ...2 OUR PLANET SEAL THE DEAL UNEP promotes environmentally sound practices globally and in its own activities. ...PaGE 30OUR PLANET SEAL THE DEAL 3

461

What's new in target volume definition for radiologists in ICRU Report 71? How can the ICRU volume definitions be integrated in clinical practice?  

UK PubMed Central (United Kingdom)

AbstractThe optimal definition of the size, shape and location of gross tumour volume is one of the most important steps in the planning of radiation therapy, and necessitates a proper...Full Text Available

462

Variability In Motor Learning: Relocating, Channeling and Reducing Noise  

UK PubMed Central (United Kingdom)

Variability in motor performance decreases with practice but is never entirely eliminated, due in part to inherent motor noise. The present study develops a method that quantifies how performers...Full Text Available

2009-02-01

463

Utilization of a Marketing Strategy at Naval Regional Medical Center Great Lakes, Great Lakes, Illinois.  

Science.gov (United States)

The study examines the question of whether or not civilian marketing practices and principles can be applied in the military care setting. Using the NRMC Great Lakes as a basis, the answer is yes--consumers of military medical care are ready to be the rec...

1983-01-01

464

Using Medicaid claims to construct dental service market areas.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To use Medicaid claims data to construct patient origin-based market areas for dental services and compare constructed market areas with those based on the practice county. DATA SOURCES:...Full Text Available

1999-12-01

465

UTK-EERC ~ Staff - Jack N. Barkenbus  

Wastenet

... Tschantz, Performance Evaluation of Constructed Urban Stormwater Detention Ponds in the Knoxville Area, proceedings and presentation to International Conference on Decision Making in Urban and Civil Engineering, Lyon, France, November 22, 2000. B.A. Tschanz, Current Problems, Practices, and ...

466

Threats and countermeasures for network security  

Science.gov (United States)

In the late 1980's, the traditional threat of anonymous break-ins to networked computers was joined by viruses and worms, multiplicative surrogates that carry out the bidding of their authors. Technologies for authentication and secrecy, supplemented by good management practices, are the principal countermeasures. Four articles on these subjects are presented.

1991-01-01

467

The translation research in a dental setting (TRiaDS) programme protocol  

UK PubMed Central (United Kingdom)

BackgroundIt is well documented that the translation of knowledge into clinical practice is a slow and haphazard process. This is no less true for dental healthcare than other types...Full Text Available

468

The feasibility of using pattern recognition software to measure the influence of computer use on the consultation  

UK PubMed Central (United Kingdom)

BackgroundA key feature of a good general practice consultation is that it is patient-centred. A number of verbal and non-verbal behaviours have been identified as important to establish...Full Text Available

469

Taking social relationships seriously: Lessons learned from the informed consent practices of a vaccine trial on the Kenyan Coast  

UK PubMed Central (United Kingdom)

AbstractIndividual informed consent is a key ethical obligation for clinical studies, but empirical studies show that key requirements are often not met. Common recommendations to strengthen...Full Text Available

2008-09-01

470

Social Work Role in Pain Management with Hospice Caregivers: A National Survey  

UK PubMed Central (United Kingdom)

This article reports on an exploratory study of hospice social workers’ assessment and collaborative practices related to pain management; especially caregiver concerns about patient...Full Text Available

2009-01-01

471

Simulation of propofol anaesthesia for intracranial decompression using brain hypothermia treatment  

UK PubMed Central (United Kingdom)

BackgroundAlthough propofol is commonly used for general anaesthesia of normothermic patients in clinical practice, little information is available in the literature regarding the...Full Text Available

472

Shaping up nucleic acid computation  

UK PubMed Central (United Kingdom)

Summary of recent advances (abstract)Nucleic acid-based nanotechnology has always been perceived as novel, but has begun to move from theoretical demonstrations to practical applications....Full Text Available

2010-08-01

473

Safety culture development at Daya Bay NPP  

International Nuclear Information System (INIS)

From view on Organization Behavior theory, the concept, development and affecting factors of safety culture are introduced. The focuses are on the establishment, development and management practice for safety culture at Daya Bay NPP. A strong safety culture, also demonstrated, has contributed greatly to improving performance at Daya Bay

2001-12-01

474

Prototype Web-based continuing medical education using FlashPix images.  

UK PubMed Central (United Kingdom)

Continuing Medical Education (CME) is a requirement among practicing physicians to promote continuous enhancement of clinical knowledge to reflect new developments in medical care. Previous research...Full Text Available

2000-01-01

475

Practical, Stereoselective Synthesis of Cecropia Juvenile Hormone  

UK PubMed Central (United Kingdom)

The high-yield, stereoselective conversion of geraniol (3,7-dimethyl-trans-2,6-octadien-1-ol) to the insect juvenile hormone, methyl 12,14-dihomojuvenate (methyl cis-10-epoxy-3,11-dimethyl-7-ethyl-trans,...Full Text Available

1971-06-01

477

Practical Applications of the Bioinformatics Toolbox for Narrowing Quantitative Trait Loci  

UK PubMed Central (United Kingdom)

Dissecting the genes involved in complex traits can be confounded by multiple factors, including extensive epistatic interactions among genes, the involvement of epigenetic regulators, and the variable...Full Text Available

2008-12-01

478

Post traumatic stress symptoms and heart rate variability in Bihar flood survivors following yoga: a randomized controlled study  

UK PubMed Central (United Kingdom)

BackgroundAn earlier study showed that a week of yoga practice was useful in stress management after a natural calamity. Due to heavy rain and a rift on the banks of the Kosi river,...Full Text Available

479

Population-based prevention of influenza in Dutch general practice.  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the effectiveness of influenza vaccination in high-risk groups has been proven, vaccine coverage continues to be less than 50% in The Netherlands. To improve vaccination rates,...Full Text Available

1997-06-01

480

Pesticide Use and Self-Reported Symptoms of Acute Pesticide Poisoning among Aquatic Farmers in Phnom Penh, Cambodia  

UK PubMed Central (United Kingdom)

Organophosphates and carbamates (OPs/CMs) are known for their acetylcholinesterase inhibiting character. A cross-sectional study of pesticide handling practices and self-perceived symptoms of acute...Full Text Available

2011-01-01

481

Organizing, Educating, and Advocating for Health and Human Rights in Vieques, Puerto Rico  

UK PubMed Central (United Kingdom)

I briefly review the process of community organization, education, and advocacy activities that ended the harmful military practices in the island-municipality of Vieques, Puerto Rico, while drawing...Full Text Available

2005-01-01

482

Naturally radioactive waste materials. Part 1. Assessment and monitoring of materials and residues  

International Nuclear Information System (INIS)

The amended Radiation Protection Ordinance of 2001 contains regulations on natural radioactive materials, whose recycling or disposal poses practical problems. There is little experience in this field so far.

2003-03-01

483

Middle segment pancreatectomy can be safely incorporated into a pancreatic surgeon's clinical practice1  

UK PubMed Central (United Kingdom)

Middle segment pancreatectomy (MSP) is a new operation where the advantages of parenchymal preservation are counterbalanced by a high postoperative complication rate and unease among surgeons with adopting...Full Text Available

2008-12-01

484

Management of the early and late presentations of rheumatoid arthritis: a survey of Ontario primary care physicians.  

UK PubMed Central (United Kingdom)

OBJECTIVE: To examine primary care physicians' management of rheumatoid arthritis, ascertain the determinants of management and compare management with that recommended by a current practice panel....Full Text Available

1996-09-15

485

Living and Working Around High-Voltage Power Lines.  

Energy Technology Data Exchange (ETDEWEB)

This booklet presents safe practices that you should follow if your activities take you near high-voltage transmission lines. It documents information that has generally been available to the public.

1981-08-01

486

Limited agreement exists between rationale and practice in athletes' supplement use for maintenance of health: a retrospective study  

UK PubMed Central (United Kingdom)

BackgroundThe widespread use of nutritional supplements among athletes is poorly understood. The prevalence of supplement intake and users' knowledge have been researched independently...Full Text Available

487

Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?  

UK PubMed Central (United Kingdom)

BackgroundCavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other...Full Text Available

488

Gratitude and Well Being  

UK PubMed Central (United Kingdom)

The word “gratitude” has a number of different meanings, depending on the context. However, a practical clinical definition is as follows—gratitude is the appreciation...Full Text Available

489

Fostering implementation of health services research findings into practice: a consolidated framework for advancing implementation science  

UK PubMed Central (United Kingdom)

BackgroundMany interventions found to be effective in health services research studies fail to translate into meaningful patient care outcomes across multiple contexts. Health services...Full Text Available

490

Failure of Intimate Partner Violence Screening Among Patients with Substance Use Disorders  

UK PubMed Central (United Kingdom)

ObjectivesThis studys examined the relationship between substance use disorder (SUD) and intimate partner violence screening (IPV) and management practices in the...Full Text Available

2010-08-01

491

Evaluation of broth disk elution methods for susceptibility testing of anaerobic bacteria with the newer beta-lactam antibiotics.  

UK PubMed Central (United Kingdom)

Broth disk elution procedures represent one of the most practical means for clinical laboratories to perform routine antibiotic susceptibility tests on anaerobic bacteria. The accuracy of five disk...Full Text Available

1986-03-01

492

Effects of a community mental health service on the practice and attitudes of general practitioners.  

UK PubMed Central (United Kingdom)

Recent years have seen closer links developing between general practitioners and mental health specialists. A study was undertaken in Manchester to determine the effects of a new community mental health...Full Text Available

1993-12-01

493

Early Post-operative Periprosthetic Femur Fracture in the Presence of a Non-cemented Tapered Wedge Femoral Stem  

UK PubMed Central (United Kingdom)

Non-cemented femoral fixation in hip arthroplasty has become the standard of practice in the USA. However, recent literature has brought attention to an increasing incidence of periprosthetic femur...Full Text Available

2010-09-01

494

Current practices in the spatial analysis of cancer: flies in the ointment  

UK PubMed Central (United Kingdom)

While many lessons have been learned from the spatial analysis of cancer, there are several caveats that apply to many, if not all such analyses. As "flies in the ointment", these can substantially...Full Text Available

495

Comparison of Indoor Mercury Vapor in Common Areas of Residential Buildings with Outdoor Levels in a Community Where Mercury Is Used for Cultural Purposes  

UK PubMed Central (United Kingdom)

Elemental mercury has been imbued with magical properties for millennia, and various cultures use elemental mercury in a variety of superstitious and cultural practices, raising health concerns for...Full Text Available

2006-01-01

496

Cognitive Pretesting and the Developmental Validity of Child Self-Report Instruments: Theory and Applications  

UK PubMed Central (United Kingdom)

ObjectiveIn the context of the importance of valid self-report measures to research and evidence-based practice in social work, an argument-based approach to validity...Full Text Available

2004-05-01

497

Clinical review: Patency of the circuit in continuous renal replacement therapy  

UK PubMed Central (United Kingdom)

Premature circuit clotting is a major problem in daily practice of continuous renal replacement therapy (CRRT), increasing blood loss, workload, and costs. Early clotting is related to bioincompatibility,...Full Text Available

2007-01-01

498

Biotypology, Endocrinology, and Sterilization: The Practice of Eugenics in the Treatment of Argentinian Women during the 1930s  

UK PubMed Central (United Kingdom)

SUMMARYThis article looks at medical approaches to women’s fertility in Argentina in the 1930s and explores the ways in which eugenics encouraged the reproduction of the...Full Text Available

2007-01-01

499

A Disordered Eating Response Team's Effect on Nutrition Practices in College Athletes  

UK PubMed Central (United Kingdom)

The disordered eating response team developed a protocol for assessment and intervention for athletes who are identified as at risk for disordered eating. Team members included the team physician,...Full Text Available

1995-10-01