Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

2

A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit  

Energy Technology Data Exchange (ETDEWEB)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.

1996-08-01

3

Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259  

Energy Technology Data Exchange (ETDEWEB)

The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

1995-05-12

4

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

5

Method of controlling the coolant level in the cooling system of a nuclear power plant  

International Nuclear Information System (INIS)

Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).

6

Parametric study of pipe whip behavior  

International Nuclear Information System (INIS)

A pipe whip test is one of the main subjects of the pipe rupture tests performed in Japan Atomic Energy Research Institute. In 1979, the pipe whip test of 4B, sch-80 pipe will be done under the BWR condition. As the preliminary analysis of this test, the pipe whip analysis of 4B, sch-80 pipe was implemented in order to make clear of the influences of the physical parameters on the pipe whip behavior. The pipe whip analysis was treated as nonlinear dynamic analysis of pipe-restraint system by using the general purpose finite element program ADINA. Overhang length, clearance between pipe and restraint, restraint length and cross section area of restraint were taken as physical parameters. It was clarified through this analysis how restraint displacement, ...

7

Experimental and analytical studies of four-inch pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

In the tests, the effects of the overhang length on the pipe whip behavior of the pipe-restraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe whip analysis is made clear through this analysis.

1984-01-01

8

WATER SUPPLY ANALYSIS  

Energy Technology Data Exchange (ETDEWEB)

This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.

1996-02-06

9

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes alined with cast basalt rings marketed under the name Abresist.

1982-09-01

10

Pipe behaviour in bottom ash slurry systems  

Energy Technology Data Exchange (ETDEWEB)

This study presents the results of an 18-year long investigation of pipe deterioration in cyclone slag slurry transport. The goal was to study pipe behaviour in this extremely abrasive service and select an optimum piping material. Comparisons are given for high quality alloy cast steel pipes and pipes lined with cast basalt rings marketed under the name Abresist. Based on the results, thoughts are offered on the broader meanings of certain findings.

1982-09-01

11

Latest trends in rolling mill facilities toward the 21st century; 21 seiki ni muketa saishin atsuen setsubi no doko  

Energy Technology Data Exchange (ETDEWEB)

Described herein are the latest trends in rolling mill facilities toward the 21st. century and new techniques developed by Hitachi Ltd. These cover hot rolling facilities, such as two-stage twin, high crown control-roll cross mill, roll shaping machine and continuous hot rolling systems; cold rolling facilities, such as pickling line-tandem cold mill and other continuous systems; and fine steel rolling facilities, such as roll mill for very small diameter pipes and others to improve productivity and product quality. The other new techniques include systems to pursue reliability and maintainability, in which electric appliances, instruments and computers are integrated, or equipped with built-in large-capacity inverters and drivers. For hot rolling, the above techniques lead to development of a new ...

1996-06-01

12

Concrete as secondary containment for interior wall embedded waste lines  

International Nuclear Information System (INIS)

Throughout the DOE complex there are numerous facilities that handle hazardous and radioactive waste solutions. Due to the hazardous constituents of the mixed waste, secondary containment of tank systems and their ancillary piping, in accordance with Resource Conservation and Recovery Act, is a concern for such existing facilities. The Idaho Division of Environmental Quality was petitioned in 1990 for an Equivalent Device determination regarding secondary containment of waste lines embedded in interior concrete walls. The petition was granted; however, it expires in 1996. To address the secondary containment issue, additional studies were undertaken. One study verified the hypothesis that an interior wall pipe leak would follow the path of least resistance through the naturally occurring void found below a rigidly supported pipe and pass into an adjacent room ...

1993-08-17

13

Pipe whip experiments involving impacts between pipes  

International Nuclear Information System (INIS)

Dynamic pipe impact tests were performed in order to determine the impact conditions for which a 2 inch Schedule 80 carbon steel target pipe would not be broken if it were impacted during a pipe whip event created by a postulated break of an adjacent larger parallel pipe. Such pipe/pipe impact scenarios are of special interest for the feeder pipes of a CANDU reactor because the large number of closely spaced parallel feeder pipes that carry coolant between large primary system pipes and individual fuel channels in the reactor core makes it impractical to consider providing feeder pipe whip restraints. The testing which was performed involved simulating the behaviour of 3 inch and larger whipping pipes in order to study their impact with 2 inch target ...

14

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the ...

1981-10-01

15

Safety gas management system utilizing telephone cable  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance ...

1988-02-10

16

Safety design guide for pipe rupture protection for CANDU 9  

Energy Technology Data Exchange (ETDEWEB)

This safety design guide for pipe rupture protection identifies high-energy systems in which pipe ruptures must be postulated to occur, as well as systems that must be protected from the dynamic effects of such ruptures. Dynamic effects considered in this SDG consist of pipe whip (including missiles generated by pipe ruptures, if any) and jet impingement, Requirements for protection against the dynamic effects of a postulated pipe rupture and method of protection of essential structures, systems and components are specified for these effects. The change status for the regulatory requirements, code and standards should be traced and this safety design guide shall be updated accordingly. 2 tabs., 5 refs. (Author) .new.

1996-03-01

17

Experimental and analytical studies of four-inch pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper presents experimental and analytical results of pipe whip tests performed under PWR LOCA conditions using a test pipe of 4-inch diameter and U-shaped restraints. In the tests, the effects of the overhang length on the pipe whip behavior of the piperestraints system were studied by measuring the strains and deformations of the test pipe and restraints, and the restraints forces. The equation for predicting the maximum strain at the outer surface of the pipe was derived using a static equilibrium condition. The calculated maximum strains at the outer surface of the pipe agree fairly well with experimental data. The dynamic response analysis of the pipe-restraints system was conducted by the finite element program ADINA. The applicability of the ADINA program to the pipe ...

1984-01-01

18

Dynamic response analysis of pipe-restraints system. Analysis of pipe whip tests performed under PWR-LOCA conditions using 4-inch test pipe  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of the dynamic response analysis of the pipe-restraints system by the general purpose finite element program ADINA. The analysis was carried out for the pipe whip tests performed under the PWR-LOCA conditions using 4-in. test pipe. In the analysis, the test pipe was modeled by an assemblage of the beam elements with the isotropic elastic-plastic material properties and the restraints were represented by the truss elements with the nonlinear elastic material properties including gap effect. The following results are obtained through the analysis. (1) Pipe can be modeled with the beam elements, when the overhang length is short and, therefore, the flattening of a cross-section of pipe is small. (2) The steady state restraint force can be predicted by modeling the restraints with the truss elements.

1983-09-01

19

The construction of earthquake damage estimation system for city gas supply system  

Energy Technology Data Exchange (ETDEWEB)

The regular occurrence of large-scale earthquakes in Japan necessitates the use of earthquake disaster prevention systems that focus on gathering damage information on gas supply facilities immediately after an earthquake strikes and minimizing the damage. This paper discussed the development of an earthquake damage estimation system for city gas pipelines that can show damage information in real-time by using earthquake records obtained from densely deployed earthquake observation networks and the most advanced telecommunication and information technologies. The paper summarized the earthquake damage estimation system (EDES) and Toho Gas disaster prevention measures. Specific topics that were discussed included the Toho Gas supply method; earthquake countermeasures; construction of computer systems; normal and emergency operation of EDES; and verification of functions in actual ...

2010-07-01

21

Reliability analysis of stiff versus flexible piping. Status report  

Energy Technology Data Exchange (ETDEWEB)

Conservative design procedures adopted for nuclear piping systems usually result in stiff piping designs that use excessive support devices such as rigid supports and snubbers. Use of these piping support devices has created safety concerns. This report describes the interim result for a piping research project conducted at Lawrence Livermore National Laboratory (LLNL) for the US Nuclear Regulatory Commission (NRC). The overall objective of this research project is to develop modified design requirements and criteria which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork for this work based on the piping reliability analysis.

1984-04-01

22

A study on the experimental verification for the pipe whip problem in a Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear power plant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip ...

1993-12-15

23

Examination of scaling criteria for nuclear reactor thermal-hydraulic test facilities  

International Nuclear Information System (INIS)

Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland ...

1987-01-01

24

Structural analysis of piping after a large pipe break in a WWER-440 type reactor  

International Nuclear Information System (INIS)

In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe in 1, 2, 3 or 4 directions depending on the geometry of the pipe near the support. Under normal conditions there is a gap of some centimeters between the pipe and a support so that the pipe can be deformed freely under changing loads. In order to analyse the behaviour of the broken piping system with the support structures a computer code called PIPEBREAK has been written. The main ...

1975-09-01

25

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe  

International Nuclear Information System (INIS)

To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).

1994-05-01

26

Federal Facility Agreement plans and schedules for liquid low-level radioactive waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank ...

1992-03-01

27

Nonlinear dynamic analysis of high energy line pipe whip  

International Nuclear Information System (INIS)

To facilitate potential cost savings in pipe whip protection design, TVA conducted a 1'' high pressure line break test to investigate the pipe whip behavior. The test results are available to EPRI as a data base for a generic study on nonlinear dynamic behavior of piping systems and pipe whip phenomena. This paper describes a nonlinear dynamic analysis of the TVA high energy line tests using ABAQUS-EPGEN code. The analysis considers the effects of large deformation and high strain rate on resisting moment and energy absorption capability of the analyzed piping system. The numerical results of impact forces, impact velocities, and reaction forces at pipe supports are compared to the TVA test data. The pipe whip impact time and forces have also been calculated per the current NRC guidelines and ...

28

Experimental and analytical studies of 4-inch pipe whip tests under PWR LOCA conditions  

International Nuclear Information System (INIS)

The purposes of the pipe rupture studies at the Japan Atomic Energy Research Institute are to perform the model tests on the pipe whip of a pipe-restraints system, to get jet impingement force and blowdown thrust force, and to establish the computational method for the analysis of these phenomena. This paper presents the experimental and analytical results of the pipe whip tests carried out under the PWR LOCA conditions using the test pipe of 4-inch diameter and the U-shaped restraints. In the tests, the gap between the test pipe and the restraints was set nearly constant and the overhang length was 250 mm, 400 mm or 650 mm. The dynamic strains and residual deformations of the test pipe and restraints, and the restraint force were measured to clarify the effects of the overhang length on the pipe ...

29

Underground piping handbook  

Energy Technology Data Exchange (ETDEWEB)

This book provides the information required to design and prepare construction drawings, and to install, inspect, test, and commission buried piping. Both pressure and gravity piping are covered, including water, steam, gases, and sewers. Directed primarily toward underground industrial piping systems, this is a succinct, well-organized compilation of practical knowledge. Checklists, examples, tables, charts, nomographs, short cuts, and helpful hints gained through years of experience complete this timely and useful ''how to'' book.

1985-01-01

30

Pipework design and operation  

Energy Technology Data Exchange (ETDEWEB)

This book presents the proceedings of a conference dedicated to the design and operation of pipework in all its aspects, involving both metallic and non-metallic materials. Topics considered include a study of single mitre pipe bends using the finite element method; tests to failure of GRP pipe bends under in-plane flexural loading; finite element stress analysis of an equal diameter branch pipe intersection subjected to internal pressure and in-plane moment loadings; finite element stress analysis of extruded outlet tee junctions; design of pipework on the British PWR; a review of advanced remanent life methods for pipes operating in the creep range; pipe whip analysis and design; damping values for piping systems; pipework snubbers based on electro-rheological fluids; and the seismic design of piping ...

1985-01-01

31

Developing DB system of piping reliability  

Energy Technology Data Exchange (ETDEWEB)

Developing DB system of piping reliability including the population data and service history of damaged piping for pilot power plant. Total weld counts of shop welds, field welds and welds for measuring instruments for 14 systems of Kori unit 3. Total weld counts of shop welds, field welds and welds for measuring instruments for 12 systems of Wolsung unit 2.

2005-03-15

32

Topical Report ''Corrosion Evaluation of LLW2 Skid-B Weld Failure Mechanisms (44139-92)  

Energy Technology Data Exchange (ETDEWEB)

An independent investigation of pipe welding leaks from the Low-Level Waste 2 (LLW2) Skid-B System for the possibilities of improper welding (IW), microbiologically influenced corrosion (MIC), sensitization, chloride pitting corrosion (CPC), and intergranular stress corrosion cracking (IGSCC) was conducted. The results show the prevailing mechanisms that caused the leaks are identified as IW, CPC, and the improper selection of weld filler material for the base metals in an environment of the North Plateau underground water. These is no evidence of MIC, sensitization, or IGSCC. The chloride pitting corrosion mechanism that took place at all the welds are also described. All the pipelines were replaced with polyvinyl chloride (PVC) for cost saving and the LLW2 Skid B System has been successfully operating since 1999. This report summarizes the findings and recommendations associated with preventive measures for future ...

2001-05-31

33

Study on potential threats against the leak tightness of the reactor containments due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems; Utredning angaaende potentiella hot mot inneslutningars taethet paa grund av roerslag fraan taenkta roerbrott i aang- och matarvattenledningar  

Energy Technology Data Exchange (ETDEWEB)

Possible threats against the leak tightness of the reactor containments, due to pipe whips from hypothetical pipe ruptures in the steam- and feedwater systems, have been investigated for Forsmark 3/Oskarshamn 3, Ringhals 1, Oskarshamn 1 and Barsebaeck 2/Oskarshamn 2. Based on available drawings, such as installation drawings and isometric views of pipes, the pipe systems have been put together in new drawings with their bracing supports and containment walls. This inventory shows that pipe whips can occur on a number of places on the containments walls after hypothetical pipe ruptures in the steam- and main feedwater systems. In order to find out whether these pipe whips are real threats against the leak tightness, further analysis needs to be made but are out of the scope of ...

2001-03-01

34

Emergency core cooling device for a reactor  

International Nuclear Information System (INIS)

Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).

1982-01-24

35

Application of probabilistic methods to validate NPP pipewhip impact simulations  

British Library Electronic Table of Contents (United Kingdom)

Piping in nuclear power plants is vital to the proper operation and safety of these facilities. To assure safety in the unlikely event of a pipe break, it is necessary to evaluate the consequences from the resulting whipping pipe on neighboring components and structures. Numerical simulations allow for rapid evaluation of these consequences. Before simulations can be accepted, however, the methodology and computer codes must be validated against experimental results. This paper uses a probabilistic approach to validate pipe whip simulations against limited experimental results. Probabilistic analysis software was developed and coupled to existing deterministic finite element software. An example of a whipping pipe impacting against a reinforced concrete slab was simulated. The described pr...

2006-01-01

36

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina nuclear power plant.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. Therefore, two cases are investigated: GDH impact on an adjacent GDH and its attached piping; and GDH impact on an adjacent reinforced concrete wall. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that ...

2002-02-26

38

WIPS: computer code for whip and impact analysis of piping systems. Summary report  

Energy Technology Data Exchange (ETDEWEB)

WIPS (Whip and Impact of Piping Systems) is a special purpose computer code for the structural analysis of pipe whip dynamic effects following a postulated pipe rupture. WIPS has been developed primarily to provide support for the pipe whip analysis procedures described in Section 3.6.2 of the US Nuclear Regulatory Commission Standard Review Plan. This report summarizes the purpose and scope of the WIPS development effort, identifying those clauses in the Standard Review Plan which refer to pipe whip analysis, and indicating how the WIPS code can be used to provide supporting data. Detailed information on use of the code is contained in accompanying reports which cover: (1) user instructions; (2) theory; (3) programming procedures; and (4) verification examples.

1984-06-01

39

Integrity of feedwater and main steam piping in KWU light water reactor plants  

Energy Technology Data Exchange (ETDEWEB)

New standard catalogs for piping, supports, and valves have been introduced by Kraftwerk Union (KWU) for the first time in its Convoy series of PWR plants. These catalogs, underlying regulatory codes, and newly developed KWU specifications are described. Feedwater and main steam piping systems within the containment, including pipe supports and valves, are used to demonstrate the high quality level of piping technology achieved in the Federal Republic of Germany. Such quality standards ensure the integrity of single components as well as of the entire system, so that, under certain conditions, pipe whip restraints against postulated breaks have become unnecessary. The quality aspects apply basically for both PWR and BWR plants of KWU.

1986-07-01

40

Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro has been assessing and upgrading its facilities and implementing response alternatives to potential damage resulting from a major earthquake. This paper reviews the utility`s seismic evaluation of its overhead transmission system, focusing on the Lower Mainland area where most of the tall critical river-crossing towers are located. The paper gives an overview of the geologic environment of the Lower Mainland and outlines the criteria used for assessing existing structures for their ability to withstand design seismic loads. It then describes the investigation and analysis methods used in the assessment, including geotechnical field tests, ground response analysis, determination of soil liquefaction potential, and dynamic analysis of structures and piles. Options for seismic upgrades are discussed and illustrated by the case of the Pitt River crossing, where tower foundations were reinforced with steel pipe piles.

1995-12-31

41

Pressure surge analyses for conventional and nuclear power plants. Druckstossanalysen fuer konventionelle und nukleare Kraftwerke  

Energy Technology Data Exchange (ETDEWEB)

There is need of pressure surge analyses when valves or pumps are activated or piping systems fail (pipe rupture). Based on actual problems the influences of boundary conditions upon fluid simulation results are discussed. Hints concerning realistic dynamic analyses of piping systems are presented. Some of the simulations results are compared with measurements. (orig.)

1993-09-01

42

Northward Market Extension for Passive Solar Water Heaters by Using Pipe Freeze Protection with Freeze-Tolerant Piping: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in freeze-protection methods that could extend market acceptance for passive solar domestic water heating systems in more northern climates if the U.S.

2006-05-01

43

Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report  

Energy Technology Data Exchange (ETDEWEB)

This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction ...

1984-07-01

44

CFD Analysis of a Dry Storage System for MACSTOR/KN-400  

International Nuclear Information System (INIS)

There are four nuclear power plants in operation at Wolsong and, annually, more than 5,000 assemblies of spent nuclear fuels are released from each plant. Thus the concrete silo type dry storage system was constructed from '90. However, after 2006, another dry storage facility is required to accept the all amount of spent nuclear fuels from the plants. Instead of the concrete silo type, MACSTOR/KN-400 was developed to store the CANDU spent nuclear fuel more densely. In this study, computational fluid dynamics (CFD) analysis of the MACSTOR/KN-400 model was performed to confirm the thermal integrity of the facility, especially for the concrete structure, using the commercial CFD code, FLUENT. The MACSTOR/KN-400 which has Thermal Insulation Panel (TIP) and IAEA Re-verification Pipe (RVP) was modeled and analyzed in the view point of the thermal integrity of the concrete structure.

2007-10-01

45

Coolant rate distribution in horizontal steam generator under natural circulation  

International Nuclear Information System (INIS)

The interrelations between the factors causing the main effects on the primary circuit coolant flow rate distribution in the horizontal steam generator pipes in reactor facilities with the WWER type reactors under the modes with natural circulation are discussed. The criterion showing the presence or absence of coolant circulation reversal in bottom rows of the steam generator pipes is obtained. It is shown that large hydraulic non-uniformity in steam generator pipes operating in parallel under coolant natural circulation leads to decreasing the heat transfer surface efficiency under reactor facility emergency cooling, restricts its servicing capabilities. The circulation reverse in steam generator pipes under coolant natural circulation mode can give unfavourable effect on separate structural elements of the steam generators and as a result it can cause ...

1997-09-01

46

A Scheme of 3-D Breakdown-whip Analysis Methodology for High Energy Piping  

Energy Technology Data Exchange (ETDEWEB)

High energy piping systems are operated with either or both conditions of maximum operating temperature exceeding 200 .deg. F(93.3 .deg. C) or maximum operating pressure exceeding 275 psig(19.3kg/cm{sup 2}) during normal operating conditions in nuclear power plants. A high energy pipe failure is postulated in branches or piping that runs larger than one inch nominal diameter. The resultant consequences of these postulated pipe breaks must be analyzed for the effect on maintenance of plant safe shutdown capability, containment integrity. And the analyzed results must be applied to the system design so that a pipe failure can not damage essential systems to an extent of impairing design function nor affect necessary component operability. The considerable effects of pipe break are as follows; dynamic ...

2007-10-15

47

Applicability of leak-before-break criteria  

Energy Technology Data Exchange (ETDEWEB)

On February 1, 1984, the US Nuclear Regulatory Commission issued Generic Letter 84-04 on the subject of postulated pipe breaks in pressurized water reactor (PWR) primary coolant loops, opening the way for pipe-whip restraint exemptions. The letter substitutes the leak-before-break (LBB) criteria for the double-ended guillotine break regarding PWR primary reactor coolant system (RCS) piping and asymmetric blowdown loads. The LBB criterion refers to the fact that a piping flaw will leak before it breaks. The current requirement to provide pipe-whip restraints is applied within the plant to all high-energy piping with a potential for damaging structures, systems, and components essential to safe reactor shutdown. This includes primary RCS piping 30 in. and larger as well as smaller ...

1986-01-01

48

GDH pipe break transient analysis of the RBMK - 1500.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. The cases of GDH impact on an adjacent GDH and its attached piping are investigated in this paper. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear ...

2002-05-15

49

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective ...

1981-10-01

50

Safety significance of ATR passive safety response attributes  

International Nuclear Information System (INIS)

The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety of the facility. The three passive safety attributes being evaluated in the paper are: 1) In-core and in-vessel natural convection cooling, 2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and 3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond to most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) models ...

1990-03-01

51

Leak-before-break strategy for CANDU primary piping systems  

Energy Technology Data Exchange (ETDEWEB)

Recent advances in elastic-plastic fracture mechanics have made it possible to assess the stability of cracks in ductile piping systems. These technological developments have been used by Ontario Hydro as the nucleus of an approach for demonstrating that CANDU primary heat transport piping systems will not break catastrophically; at worst they would leak at a detectable rate. This leak-before-break approach has been taken on the Darlington nuclear generating station as a design stage alternative to the provision of pipe whip restraints on large diameter, primary heat transport system piping. Positive conclusions reached via this approach are considered sufficient to exclude the requirement to provide protective devices, such as pipe whip restraints. In arriving at the proposed leak-before-break approach a review of ...

1986-01-01

52

Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report  

Energy Technology Data Exchange (ETDEWEB)

Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.

1987-01-01

53

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

54

Approximate method for the determination of the response frequency of pipe whip. [With fluid flowing in the pipe at different velocities  

Energy Technology Data Exchange (ETDEWEB)

An approximate analysis based on the virtual work technique, which was used to determine the effect of fluid velocity on the response frequency of a simply supported pipe, resulted in the following conclusions: (1) the critical fluid velocity at which the system becomes statically unstable is 129.5 ft/s; (2) the natural frequency of the pipe decreases as the fluid velocity increases; (3) higher flow rates increase the dynamic coupling of the system, making it much more susceptible to external excitation; (4) as the critical frequency approaches zero and the fluid velocity approaches the critical value, the amplitude becomes greater (though in an actual pipe, damping effects will limit the amplitude somewhat); and (5) the virtual work technique is a convenient method for approximating solutions to most non-linear vibration problems, giving results that are satisfactory for ...

1980-05-01

55

Oscillating line travel pipe cleaning machine  

Energy Technology Data Exchange (ETDEWEB)

A major problem in the maintenance and rehabilitation of pipelines is the removal of the original coating system, particularly in cases where the coating contains sticky components or adhesives. It has been found that such coatings can be removed by use of a cleaning machine with a plurality of counter-rotating carbide-tipped tools mounted to an oscillating head embracing the pipe, and which is operable at the same time to travel along the length of the pipe. Such a machine can be designed to effect a positive, gentle milling operation on the pipe surface to remove the coating efficiently and at relatively low power consumption. A particular advantage of the pipe cleaning machine of the invention is that its design and manner of operation allows it to be used in the field to clean an uncovered section of pipeline, for example a natural gas pipeline, without the requirement of ...

1992-04-28

56

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

Energy Technology Data Exchange (ETDEWEB)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder ...

2007-07-01

57

CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue  

International Nuclear Information System (INIS)

From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder ...

2007-05-10

58

Assessment of value-impact associated with the elimination of postulated pipe ruptures from the design basis for nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The US Nuclear Regulatory Commission is proposing to amend the regulations that currently require that the design basis for nuclear power plants include the postulation of dynamic effects from loss of coolant accidents up to and including the double-ended rupture of the largest pipe in the reactor coolant system. Proposed modifications would allow analyses to serve as a sufficient basis for excluding dynamic effects, including but not necessarily limited to pipe whip and jet impingement, associated with specific pipe ruptures. Only dynamic effects would be impacted; current design requirements for containment sizing and discharge capacity of emergency core cooling systems would remain unchanged. This report presents a detailed analysis of value-impact associated with the proposed amendment for PWR reactor coolant loop piping and for BWR recirculation loop ...

1985-03-29

59

Application of probabilistic methods to validate NPP pipewhip impact simulations  

Energy Technology Data Exchange (ETDEWEB)

Piping in nuclear power plants is vital to the proper operation and safety of these facilities. To assure safety in the unlikely event of a pipe break, it is necessary to evaluate the consequences from the resulting whipping pipe on neighboring components and structures. Numerical simulations allow for rapid evaluation of these consequences. Before simulations can be accepted, however, the methodology and computer codes must be validated against experimental results. This paper uses a probabilistic approach to validate pipe whip simulations against limited experimental results. Probabilistic analysis software was developed and coupled to existing deterministic finite element software. An example of a whipping pipe impacting against a reinforced concrete slab was simulated. The described probabilistic approach was used to validate the numerical simulations. The ...

2006-02-15

60

LOOP Inc. (Louisiana Offshore Oil Port Inc. ) to start onshore construction this year  

Science.gov (United States)

A discussion covers the LOOP project to construct an offshore pipeline system, which will connect with onshore facilities at Fourchon, La., and two onshore pipelines (26 mi 48 in. Clovelly line and 53 mi 48 in. LOCAP line) connecting Fourchon with the existing Capline system at St. James, La.; the three-phase construction schedule, the first phase due to begin in the third quarter of 1978 with, e.g., onshore pipeline and salt dome storage facility construction which will yield an expected initial throughput of 1.4 million bbl/day; the marine terminal complex, consisting of control and pumping platforms, and three 7000 hp pumps to operate the system at 45,000-100,000 bbl/hr; the offshore lines, including lines between single-point mooring units and the pumping platform, the 21 mi 48 in. pipe to Fourchon, and corrosion protection of lines by an asphalt-sand ...

1978-06-01

61

Effects of postulated event devices on normal operation of piping systems in nuclear power plants. Technical report  

Energy Technology Data Exchange (ETDEWEB)

This report considers the effect of pipe-whip restraints and snubbers on the normal operation of piping systems in nuclear power plants. Also considered are the effect of these postulated event devices on reliability, economics, and the exposure of plant personnel to radiation. Field data were gathered from three nuclear power plants that had applied for Operating Licenses. Criteria, design philosophies, and data were obtained from the respective nuclear steam system suppliers, architects-engineers and utilities.

1981-05-01

62

A.C.R.O. activity report 2001; A.C.R.O. rapport d'activite 2001  

Energy Technology Data Exchange (ETDEWEB)

As regards the environmental protection, the A.C.R.O. maintained in 2001 its programs of surveillance around the main western nuclear installations of France. The radioecological surveillance of the site of Cogema La-Hague for the dismantling of the former pipe of release in sea was one of the key points of this action environmental surveillance. The two accidents of atmospheric release in may and october 2001 at Cogema La Hague have shown the interest of an association as A.C.R.O.. It is thank to the measure, by our laboratory, of repercussions on environment of these incidents that it has been possible to bring to light a dysfunction of the measurement system of the gaseous effluents released by the facility operator. To improve the public information, A.C.R.O. concerns its main efforts on the development of the consumer technical information available on-line via its web site and in its regular publication 'the ...

2001-07-01

63

Development of a combined ultrasonic and eddy current inspection system for examination of the internal surfaces of water-filled austenitic piping  

Energy Technology Data Exchange (ETDEWEB)

After October 1993, Swedish BWR power plant operators will be required to present an inspection concept which will facilitate the nondestructive examination of recirculation system piping. According to the pertinent Swedish codes and standards, such inspections will be required to focus on internal pipe surfaces. Since it is impossible for external inspections to cover all essential areas with the necessary degree of sensitivity (geometry, beam attenuation), Siemens-KWU was commissioned to develop an inspection system which combines ultrasonic search units and eddy current probes to produce the required degree of examination sensitivity. A pipe crawler was developed to transport the inspection unit. This device can be used for the inspection of circumferential and longitudinal pipe welds, nozzle-to-pipe welds and RPV nozzle-to-shell welds. ...

1994-12-31

64

Virtual Stove Pipes - NASA  

Science.gov (United States)

Orchestration Layer. Service Delivery . Datacenter. Infrastructure. Systems call API. E2E automated. Automate service-levels. Analyze & ...

65

Systems analysis programs for hands-on integrated reliability evaluations (SAPHIRE) Version 5.0. Fault tree, event tree, and piping & instrumentation diagram (FEP) editors reference manual: Volume 7  

Energy Technology Data Exchange (ETDEWEB)

The Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) refers to a set of several microcomputer programs that were developed to create and analyze probabilistic risk assessments (PRAs), primarily for nuclear power plants. The Fault Tree, Event Tree, and Piping and Instrumentation Diagram (FEP) editors allow the user to graphically build and edit fault trees, and event trees, and piping and instrumentation diagrams (P and IDs). The software is designed to enable the independent use of the graphical-based editors found in the Integrated Reliability and Risk Assessment System (IRRAS). FEP is comprised of three separate editors (Fault Tree, Event Tree, and Piping and Instrumentation Diagram) and a utility module. This reference manual provides a screen-by-screen guide of the entire FEP System.

1994-07-01

66

Pipe Freeze Prevention for Passive Solar Water Heaters Using a Room-Air Natural Convection Loop: Preprint  

Energy Technology Data Exchange (ETDEWEB)

Conference paper regarding research in the use of freeze prevention for passive solar domestic water heating systems.

2006-05-01

67

Long-term storage of solar heat  

Energy Technology Data Exchange (ETDEWEB)

Stochastic models for the simulation of global radiation are discussed. Thermal transients in the ground are analyzed. The performance of buried-pipe storage and a space heating system with long-term storage is described.

1981-06-01

68

Electrical Transmission Line Diametrical Retention Mechanism  

Science.gov (United States)

The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine ...

2006-01-03

69

FFTF report: FFTF piping installation and welding techniques  

International Nuclear Information System (INIS)

The main sodium piping with a diameter of 16'' or 28 '' is being installed at the FFTF construction site starting in December 1974. The supplier and authority demarcations are: Combustion Engineering supplies the reactor vessel, guard vessel and adjoining pipes and uses the machine welding equipment ''Dimetrics''; for the piping system of the primary and secondary loops the pipes manufactured by Rollmet at HUICO, Pasco, were delivered and prefabricated there, as far as compatible with the installation. ''Astroarc'' welding machines are used by Bechtel for the piping prefabrication in the weld laboratory as well as on site at the construction site. Technical welding problems occurring during the course of the installation at the construction site and several during this time are described. At present 6 weld seams in the reactor and 14 weld seams in the secondary ...

70

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

Stress corrosion cracks have been discovered in Group Distribution Headers (GDH) at the Ignalina and Chernobyl Nuclear Power Plants. This increases the probability that a guillotine pipe break can occur that creates a whipping pipe (GDH) with the potential to damage surrounding structures-i.e. adjacent GDH and its attached piping or adjacent reinforced concrete compartment wall. The GDH is the most important component for reactor safety in case of an accident. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the ECSS into the GDH. Presented in this paper is the transient analysis of a Group Distribution Header following a guillotine break at the blind end of the header. Using a very conservative force loading function, the transient response of a whipping RBMK-1500 GDH along with ...

2007-04-15

71

Participative risk management in the construction of onshore pipelines  

Energy Technology Data Exchange (ETDEWEB)

This paper described a risk control management tool that has been developed by Petrobras Petroleo, the largest Brazilian oil company and one of the world's leading oil companies. The system covers health, safety and environmental (HSE) issues regarding pipeline construction projects. The limitations of traditional safety management systems for coping with the critical problems related to environmental safety issues were discussed. In particular, this paper described how the HSE tool evaluates the risks resulting from the following aspects of onshore pipeline construction and assembly: establishing right-of-way and route locations, transporting pipe, developing the construction site, opening the trench, pipe laying, pipe bending, concrete external coating, welding, external anticorrosive coatings, pipe placement backfilling, hydrostatic testing, ...

2000-07-01

72

Upgrading the ampacity of HPFF pipe-type cable circuits  

Energy Technology Data Exchange (ETDEWEB)

The upgrading of several 69 kV pipe-type cable feeders on the Potomac Electric Power Company (PEPCo) transmission cable system is discussed. The methods used for the ampacity calculation are described. The fluid circulation approach required to meet the feeder emergency load requirements are discussed. For the feeders that were in service for approximately 40 years, a system life evaluation was performed.

1994-12-31

73

New advances in mitigating environmental impact of pipe-type cables  

Energy Technology Data Exchange (ETDEWEB)

Through a comprehensive and aggressive research program Consolidated Edison Company of New York, Inc. (Con Edison) has designed, developed, and installed several new products to address the environmental impact of dielectric fluid from pipe-type cable systems. These include: On Line Leak Detection, Leak Location, Retractable Flow Direction Indicator, Full Stop Joints, and Transition Joints. This paper describes the application of the aforementioned products on the Con Edison underground transmission system.

1999-04-01

74

Analysis of chlorinated polyvinyl chloride pipe burst problems :Vasquez residence system inspection.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the investigation regarding the failure of CPVC piping that was used to connect a solar hot water system to standard plumbing in a home. Details of the failure are described along with numerous pictures and diagrams. A potential failure mechanism is described and recommendations are outlined to prevent such a failure.

2005-10-01

75

Research and development of neutron radiography in IAERU  

Energy Technology Data Exchange (ETDEWEB)

In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the ...

1995-03-01

76

An Experimental Study of Oil / Water Flow in Horizontal Pipes  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this thesis is to study the behaviour of the simultaneous flow of oil and water in horizontal pipes. In this connection, two test facilities are used. Both facilities have horizontal test sections with inner pipe diameters equal to 2 inches. The largest facility, called the model oil facility, has reservoirs of 1 m{sub 3} of each medium enabling flow rates as high as 30 m{sub 3}/h, which corresponds to mixture velocities as high as 3.35 m/s. The flow rates of oil and water can be varied individually producing different flow patterns according to variations in mixture velocity and input water cut. Two main classes of flows are seen, stratified and dispersed. In this facility, the main focus has been on stratified flows. Pressure drops and local phase fractions are measured for a large number of flow conditions. Among the ...

2001-07-01

77

Electron-beam welding of valve bodies; Elektronenstrahlschweissen von Armaturengehaeusen  

Energy Technology Data Exchange (ETDEWEB)

In early March, 2000 a modern electron-beam welding facility for both series and one-off production of valves bodies (500 kg, up to 50 mm wall thickness) was commissioned at Josch Strahlschweisstechnik. Welding is performed under a fine vacuum. This permits not only the welding of components subject to acceptance inspection (HP0 approval), but also of special materials such as titanium, molybdenum, tungsten, Hastelloy and copper, and also their pairings. Products are developed and readied for production using modern 3D CAD software. A modern nine-axis control system makes it possible to produce sockets in pipe-on-pipe joints. (orig.) [German] Anfang Maerz 2000 wurde eine moderne Elektronenstrahlschweissanlage fuer die Herstellung von Armaturengehaeusen in Grossserien oder auch fuer Einzelfertigung (500 kg, bis 50 mm Wanddicke) bei der Josch Strahlschweisstechnik in Betrieb genommen. Die Schweissungen erfolgen im Feinvakuum. ...

2000-03-01

78

Wall thinning trend analyses for secondary side piping of Korean NPPs  

International Nuclear Information System (INIS)

Since the mid-1990s, nuclear power plants in Korea have experienced wall thinning, leaks, and ruptures of secondary side piping caused by flow-accelerated corrosion (FAC). The pipe failures have increased as operating time progresses. In order to prevent the FAC-induced pipe failures and to develop an effective FAC management strategy, KEPRI and KOPEC have conducted a study for developing systematic FAC management technology for secondary side piping of all Korean nuclear power plants. As a part of the study, FAC analyses were performed using the CHECWORKS code. The analysis results were used to select components for inspection and to determine inspection intervals on each nuclear power plant. This paper describes the introduction of the FAC analysis method and the wall thinning trend analysis results by reactor type, system, and water treatment amine. This paper also represents the ...

2003-08-17

79

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves ...

1985-07-03

80

Analysis of postulated FFTF pipe ruptures  

International Nuclear Information System (INIS)

A detailed assessment of the FFTF Primary Heat Transport System (PHTS) piping has led to the conclusion that the integrity of the piping is assured such that there is no realistic potential for a rupture. Nevertheless, consistent with the practice of showing design margins even for hypothetical events, a spectrum of postulated PHTS ruptures has been analyzed. The analyses showed that upstream of the reactor vessel inlet downcomer, rupture areas of any size including a double-ended rupture could be tolerated with no core coolant boiling. At the most limiting location, the reactor inlet nozzle, rupture areas of 75 in."2 and 55 in."2 could be tolerated for three-loop and two-loop operation, respectively. This paper will present the following: (1) the criterion with which consequences of postulated pipe ruptures are compared; (2) the general transient response of the FFTF to postulated ruptures; and (3) the ...

81

Structural analysis and stress evaluation system for steel structures: ADAMS  

Energy Technology Data Exchange (ETDEWEB)

In order to perform the structural analysis and stress evaluation for frame structures in the nuclear power plants, ADAMS (AIJ Design Analysis and Modules System) has been developed by the addition of the following functions to the ICES-STRUDL system. 1. Load combination and stress evaluation on the basis of specifications for designing steel structure (issued by the Architecture Institute of Japan). 2. Combination of load and stress evaluation of piping support on the basis of the regulations of Ministry of International Trade and Industry. 3. Addition of other functions than that described above. ADAMS enables structural analysis and stress evaluation exactly and efficiently not only for a large scale structure such as the pipe whip protection structure installed inside of the primary containment vessel for many loading cases but also for a large number of structures such as ...

1980-11-01

82

Assessment of RELAP5/MOD2 against natural circulation experiments performed with the REWET-III facility  

Energy Technology Data Exchange (ETDEWEB)

Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code's ability to represent the main phenomena of experiments in both cases was satisfactory.

1992-04-01

83

Assessment of RELAP5/MOD2 against natural circulation experiments performed with the REWET-III facility  

Energy Technology Data Exchange (ETDEWEB)

Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code`s ability to represent the main phenomena of experiments in both cases was satisfactory.

1992-04-01

84

Assessment of RELAP5/MOD2 against natural circulation experiments performed with the REWET-III facility  

International Nuclear Information System (INIS)

Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code's ability to represent the main phenomena of experiments in both cases was satisfactory.

1992-01-01

85

Dynamic Rating and Underground Monitoring System (DRUMS)  

Energy Technology Data Exchange (ETDEWEB)

Drums is an acronym for Dynamic Rating and Underground Monitoring System, with specific application to high-pressure pipe-type cable systems which are the predominant means of underground electric power transmission in the United States. The primary objective of this EPRI-sponsored feasibility study was to establish the technical feasibility of seven DRUMS functions and two novel DRUMS communication schemes. The seven DRUMS functions which monitor the system's vital and measurable parameters in real time and perform system diagnostics in the event of component deterioration, malfunction or failure are: Real Time Current Monitoring and Rating; Leak Detection and Location; Fault Location; Pothead Monitoring; Oil Monitoring; Pipe Protection; and Splice Monitoring. The two DRUMS communication schemes are internal to the pipe cable ...

1991-07-01

86

Probabilistic leak before break evaluation of straight pipes of primary heat transport piping of Tarapur-3 and 4 NPP  

International Nuclear Information System (INIS)

Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak ...

2006-11-01

87

Evaluation of improvements in the installation of rural underground transmission lines: Final report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of an investigation into currently used methods for installation of underground high voltage power transmission cable, and offers recommendations for potentially improving these methods. Suggested enhancements cover the emplacement of both high pressure oil filled (HPOPT) pipe type and self contained oil filled (SCOF) cable systems. Cost comparisons of conventionally installed cable systems versus systems using proposed techniques and equipment are developed for a specific site selected for study. The report also documents the test results of laboratory experiments conducted to demonstrate the feasibility of using interference fit pipe couplings in place of welded pipe joints. 10 refs., 31 figs., 15 tabs.

1987-10-01

88

Thailand: utilisation programme set for massive expansion  

Energy Technology Data Exchange (ETDEWEB)

The US$360 million project to increase gas supplies to Eastern and Southern Thailand is discussed, and the use of international competitive bidding to purchase the line pipe and other facilities is reported. The government approved proposal for a gas fired combined-cycle power station and gas separation plant are discussed. (UK).

1991-11-01

89

Resolution of key safety-related issues in FFTF regulatory review  

International Nuclear Information System (INIS)

The FFTF is an ERDA facility which does not require licensing, but a technical review by NRC is required by ERDA policy. Safety issues which were not fully resolved in the course of the review for construction authorization have been the subject of continuing review since mid-1973. These issues included HCDA energetics, design fallback provisions for additional safety margins, piping integrity, and natural circulation core cooling.

90

Analysis of cost-effective pipe insulation requirements  

Energy Technology Data Exchange (ETDEWEB)

The proposed ASHRAE/IES Standard 90.1-1989R contains updated requirements for pipe insulation thicknesses developed on the basis of technical and economic principles. These requirements were determined based on computer simulations of the annual energy loss through the insulation, first cost assumptions for the insulation, and economic assumptions of discount rate and energy escalation rate. In later work, the same tools were used to analyze the sensitivity of the cost-effective insulation level for piping insulation to variations in operating hours, ambient temperature, fluid temperature, and economic assumptions. These analyses were carried out using cost data for pipe insulation averaged across several sources. The results of the sensitivity study showed that system operating hours is a critical parameter in determining the cost-effective pipe insulation thicknesses. Although ...

1997-09-01

91

Inspection pig for gas pipeline  

Energy Technology Data Exchange (ETDEWEB)

The ultrasonic inspection pig system was described as being under development. This system was said to adopt the unique wheel type ultrasonic sensor which does not need couplant. This pig was designed to detect external corrosion in long-distance pipelines without interruption of the gas service. The wall-thickness measurement performance test and the travel performance test of the inspection pig in the test line confirmed that these performances satisfied the development specifications. However, the effect induced by the inner surface properties of the pipe and the influence of the pipe`s performance over long distances and for a long period of time still needed to be verified in an actual gas pipeline, and while the pipeline was actually in service. Improvements to the prototype model of the inspection pig were expected to include combinations of inspection pigs, with increases in battery and memory ...

1992-12-31

92

Laboratory development of +- 600 kVdc pipe type cable systems  

Energy Technology Data Exchange (ETDEWEB)

In 1976, the US Department of Energy and New York State - ERDA granted a contract for the development of a +-600 kV dc underground transmission cable system looking to inevitable future requirements in the US for economic, high-capacity, long-distance underground transmission linking remote generating stations to metropolitan load centers. This project was comprehensive and dealt with three separate system components, i.e., cable, splice, and terminals. In each instance, for each component, development required an intensive R and D effort, focused on the following categories: insulating materials, model testing, design of full-scale prototype, manufacturer of prototype, and laboratory development testing. Insulating papers and oils were selected, and model studies performed, for both self-contained type and pipe type oil-filled cables. However, only the pipe cable design was finally designated for ...

1982-07-01

93

Calculating ac/dc resistance ratios for high-pressure oil-filled cable Designs. Volume 1. Designer's guide. Final report  

Energy Technology Data Exchange (ETDEWEB)

Using electromatic field theory, a new method is developed for calculating alternating current in power cables installed in pipes of carbon steel (magnetic pipes). The technique for evaluating these losses is based on the method of images which replaces complicated distribution of currents in the system with a sequence of thin conductors. The method not only gives a mathematical framework for the solution of alternating current losses, but it also gives the underlying physical picture of effects contributing to these losses. Skin effect, proximity effect and losses due to the pipe are calculated separately. For the first time, the increase of losses in the conductors, when the cables are placed in a magetic pipe, are analyzed mathematically. Good agreement is obtained between the result of calculations and the experimentally determined ac-dc resistance ratios for ...

1985-04-01

94

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

95

Freezing phenomena in ice-water systems  

Energy Technology Data Exchange (ETDEWEB)

The characteristics of solidification and melting are reviewed. The properties of water and ice and the phase diagram of water are discussed with special emphasis on ice density. A concise account of the freezing process and the Stefan problem is presented. To this end, the four stages of freezing are identified, supercooling, nucleation and the formation of dendritic ice, the growth of concentric rings of solid ice at 0{sup o}C and the final cooling of the solid ice are treated in some detail. The subject of bursting of pipes is given particular emphasis. Attention is drawn to a common misconception on pipe bursting and to misleading relationships for the computation of freezing time for ice blockage. Several current applications of melting and freezing systems are outlined. (author)

2002-09-01

96

Application of probabilistic safety assessment models to risk-based inspection of piping  

International Nuclear Information System (INIS)

From the beginning, one of the most useful applications of Probabilistic Safety Assessment (PSA) is its use in evaluating the risk importance of changes to plant design, operations, or other plant conditions. Risk importance measures the impact of a change on the risk. Risk is defined as a combination of the likelihood of failure and consequence of the failure. The consequence can be safety system unavailability, core melt frequency, early release, or various other consequence measures. The goal in this PSA application is to evaluate the risk importance of an ISI process, as applied to plant piping systems. Two approaches can be taken in this evaluation: Current PSA Approach or the Blended Approach. Both are discussed here.

1996-07-21

97

Verification of the CFD code FLUENT by post test calculation of ROCOM experiments  

International Nuclear Information System (INIS)

Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV ...

2005-10-02

98

IMPROVED NATURAL GAS STORAGE WELL REMEDIATION  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report ...

2001-12-01

99

W-12 valve pit decontamination demonstration  

Energy Technology Data Exchange (ETDEWEB)

Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means ...

1995-12-01

102

PowerPoint Presentation  

Wastenet

facilities, building hygienic latrines and introducing regular solid waste collection systems . These methods are constantly being developed and

104

Behaviour of nonlinear supports on a PWR coolant system during a postulated LOCA. Pt. 1; Effect of modelling methods  

Energy Technology Data Exchange (ETDEWEB)

A 4-loop Pressurised Water Reactor (PWR) primary coolant system has been analysed for the postulated Loss of Coolant Accident (LOCA) event in order to derive peak dynamic loads for qualifying the design of equipment supports and pipe whip restraints. Pipe whip restraints as well as pipe and equipment supports are nonlinear by nature because of the presence of gaps and the different directional stiffnesses arising from snubber, steelwork and geometric and material interaction at the concrete to steel embedment. The different structural idealisations for the supports and restraints have an influence on the dynamic response of the structure. In the first of the two part paper a range of idealisation models for the Steam Generator and Reactor Coolant Pump vertical columns ranging from elastic stiffnesses to bilinear stiffnesses with or without preload were examined. Due to both structural and loading ...

1993-07-01

105

Condensation driven water hammer studies for feed water distribution pipe  

International Nuclear Information System (INIS)

Special T-shaped feedwater distribution pipes were installed in steam generators at the Loviisa (Finland) and Rovno (Russia) nuclear power plants. The new shape was tested in an extensive testing programme. Since the tubes frequently suffer from corrosion damage, large-scale water hammer experiments were performed on a model facility in 1996. The main objectives of the water hammer experiments were to find out the prevailing parameters leading to water hammers, as well as the sensitivity of hammering to boundary conditions. A water hammer may occur when the mass flow rate into the steam generator exceeds 6 kg/s and the temperature difference between steam generator and feedwater exceeds 100 degC. Visual experiments and stress analyses of the pipe were also carried out. The weakest part, the T-joint, may hold against such water hammers only for a limited time of the order of few minutes. (M.D.).

1997-05-26

106

Less BOP running with variable bore rams  

Energy Technology Data Exchange (ETDEWEB)

The marine ram-type blowout preventer deployed from an offshore drilling rig has one serious disadvantage, its inaccessibility. A development to promote reliability of the subsea ram-type preventer and reduce the excess running and pulling to charge out rams, is the variable bare ram (VBR). Unlike the standard ram, the VBR has the ability to pack off a range of pipe sizes. Interest in VBR's has been revived and research and development in this equipment goes on at each of three manufacturer's facilities in Houston.

1984-04-01

107

Effect of Cr content, hardness and micro structure on flow-accelerated corrosion in carbon steel pipes. Examination of replaced carbon steel pipes  

International Nuclear Information System (INIS)

68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not correlated with wall ...

2008-10-01

108

Analysis of deteriorating processes in primary circuit facilities and determination of their priorities and relevance to the lifetime of the main primary circuit components  

International Nuclear Information System (INIS)

The major degradation mechanisms acting during the aging of selected WWER-440/213 primary circuit facilities were assessed critically. The analysis gave evidence that such mechanisms include radiation and fatigue damage of the reactor pressure vessel (effect of the neutron flow, cyclic fatigue promoted by the corrosive medium, effect of thermal aging), corrosion-mechanical and thermo-mechanical (fatigue) damage of the steam generator (stress corrosion cracking, erosion corrosion, thermal aging, wear), thermal and dynamic aging of the pressurizer, and corrosion-mechanical damage of the primary circuit piping (thermal aging, corrosion). (J.B.). 5 tabs., 1 fig., 62 refs.

109

Evaluation of structural integrity of crossover leg piping system with dynamic whip restraints  

Energy Technology Data Exchange (ETDEWEB)

Interference between the crossover leg of the Reactor Coolant System(RCS) and the Pipe Whip Restraints(PWR) has brought a degradation issue of the integrity of the Reactor Coolant System in Westinghouse type Nuclear Power Plants(NPPs) of Korea. According to the gap inspection carried out during planned overhaul (year 2000), interference between the crossover leg and the PWR was found in each RCS loop. This plant has had the high vibration problem on the RC pump 'B'. The reason for the high vibration in the RC pump 'B' had been massively surveyed and it was found that the crossover leg of RCS contacted with the PWR in hot condition. Since the contact between the crossover leg and the PWR changes the dynamic characteristics of the piping system for the RCS, this is considered as one reason for the high vibration. And a possibility of overstress on ...

2001-07-01

110

Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices  

British Library Electronic Table of Contents (United Kingdom)

Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...

2012-01-01

111

Solar Cogeneration Facility: Cimarron River Station, Central Telephone and Utilities-Western Power. Executive summary  

Energy Technology Data Exchange (ETDEWEB)

A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.

1981-08-07

112

Free and forced convective cooling of pipe-type electric cables. Volume 2: electrohycrodynamic pumping. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers ...

1981-05-01

113

Free and forced convective cooling of pipe-type electric cables. Volume 1: forced cooling of cables. Final report  

Energy Technology Data Exchange (ETDEWEB)

A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit ...

1981-05-01

114

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

115

Calculating ac/dc resistance ratios for high-pressure oil-filled cable designs. Volume 2. Details of mathematical derivations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional methods for calculating electricity losses in pipe-type cable systems rely heavily on data measured in lower-voltage systems in the 1950s. With the new technique developed in this study, engineers can compute power losses more precisely for cables of various configurations and voltage ratings.

1985-04-01

116

A thermal valve heat flux control device  

International Nuclear Information System (INIS)

In order to evacuate the residual power in a nuclear reactor, a thermal valve system is presented for the modification of the heat exchange conditions at the pool exchanger level, which avoids the use of mechanical valves on the pipes. The system involves a vessel containing the exchanger, with openings at the upper end of the vessel and means for feeding the fluid at the lower end, and means for controlling the opening width.

1994-10-05

117

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

118

Reactor component inventory system at FFTF  

International Nuclear Information System (INIS)

A reliable inventory control system was developed at the Fast Flux Test Facility (FFTF) to keep track of the occupancy of 900 refueling facility locations, to compile historical data on the movement of each reactor assembly, and to simulate assembly moves. The simulate capability is valuable because it allows verification of documents before they are issued for use in the plant, and eliminates the possibility of planning illegal or impossible moves. The system is installed on a UNIVAC 1100 computer and is maintained using a data base management system by Sperry Univac called MAPPER.

1985-09-08

119

Development of electronic imaging system for real time neutron radiography at TRIGA MK-II research reactor of AERE, Savar, Dhaka and utilization for research and industrial applications  

International Nuclear Information System (INIS)

The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)

2008-09-01

120

Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests  

Energy Technology Data Exchange (ETDEWEB)

This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe.

1987-01-01

121

Pipe whip: a summary of the damage observed in BNL pipe-on-pipe impact tests  

International Nuclear Information System (INIS)

This paper describes examples of the damage resulting from the impact of a whipping pipe on a nearby pressurised pipe. The work is a by-product of a study of the motion of a whipping pipe. The tests were conducted with small-diameter pipes mounted in rigid supports and hence the results are not directly applicable to large-scale plant applications where flexible support mountings are employed. The results illustrate the influence of whipping pipe energy, impact position and support type on the damage sustained by the target pipe. (author).

122

Effect of water chemistry improvement on flow accelerated corrosion in light-water nuclear reactor  

International Nuclear Information System (INIS)

Flow Accelerated Corrosion (FAC) of Carbon Steel (CS) piping has been one of main issues in Light-Water Nuclear Reactor (LWRs). Wall thinning of CS piping due to FAC increases potential risk of pipe rupture and cost for inspection and replacement of damaged pipes. In particular, corrosion products generated by FAC of CS piping brought steam generator (SG) tube corrosion and degradation of thermal performance, when it intruded and accumulated in secondary side of PWR. To preserve SG integrity by suppressing the corrosion of CS, High-AVT chemistry (Feedwater pH9.8#+-#0.2) has been adopted to Tsuruga-2 (1160 MWe PWR, commercial operation in 1987) in July 2005 instead of conventional Low-AVT chemistry (Feedwater pH 9.3). By the High-AVT adoption, the accumulation rate of iron in SG was reduced to one-quarter of that under conventional Low-AVT. As a result, a tendency to degradation of ...

2009-10-01

123

Strain Rate Effects in SA-106 Carbon Steel Pipe,  

Science.gov (United States)

... rate on the tensile properties of SA-106 carbon steel pipe, in support of analysis and experimental modeling of postulated pipe whip in nuclear ...

1982-02-01

124

Field validation of cable monitoring and rating system (CMARS) laboratory model. Semi-annual report, 1 May 1979-31 December 1979  

Energy Technology Data Exchange (ETDEWEB)

One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)

1980-01-01

125

Reasons for decision in the matter of TransCanada PipeLines Limited. Motifs de decision (relative a) TransCanada Pipelines Limited; Volume 3. Installations, exportations de gaz et demandes deposees en vertu de l'article 71  

Energy Technology Data Exchange (ETDEWEB)

TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to ...

1991-04-01

126

Reasons for decision in the matter of TransCanada PipeLines Limited  

Energy Technology Data Exchange (ETDEWEB)

TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to ...

1991-04-01

127

Brazilian onshore pipelines rehabilitation program  

Energy Technology Data Exchange (ETDEWEB)

Brazil currently has an oil and transport system with approximately 15,000 km of pipeline. However, energy needs are now increasing due to rapid population growth and expanding industrial activities in the country. This paper provided details of a pipeline rehabilitation program conducted across 424 km of pipeline in northeastern Brazil. The pipeline crossed 32 municipal districts. Over 37 replacements and upgrades were completed as part of the rehabilitation program. Surveys were completed to verify depth of pipeline cover, as well as to examined the condition of the external pipe coating, and the operational status of the cathodic protection (CP) system. Shutdown of the pipeline was completed during a 14 hour period, and included depressurization, cutting work, welding, and repressurization. Services included pigging to evaluate pipe-wall thickness; corrosion section replacement; an investigation of ...

2004-07-01

128

Cold regions hydrology and hydraulics  

Energy Technology Data Exchange (ETDEWEB)

This monograph addresses a narrow aspect of cold regions engineering, namely the effects of cold weather on the traditional civil engineering disciplines of hydrology and hydraulics. Hydrologic and hydraulic considerations in the design, construction, and operation of civil works are very important. Many of the problems encountered in the design and construction of buildings, transportation systems, water supply facilities, waste treatment facilities, and hazardous waste disposal facilities, for example are closely tied to the characteristics of the site hydrology.

1990-01-01

129

Software Configuration Management Plan for the Sodium Removal System  

Energy Technology Data Exchange (ETDEWEB)

This document establishers the Software Configuration Management Plan (SCMP) for the software associated with the control system of the Sodium Removal System (SRS) located in the Interim Examination and Maintenance (IEM Cell) Facility of the FFTF Flux Test.

2000-03-06

130

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

132

Fast Flux Test Facility performance monitoring management information, April 1988  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators.

1988-05-01

133

Los Alamos DP West Plutonium Facility decontamination project  

Energy Technology Data Exchange (ETDEWEB)

The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation.

1982-01-01

134

Detection of concealed mercury with thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

In the United States today, governments at all levels and the citizenry are paying increasing attention to the effects, both real and hypothetical, of industrial activity on the environment. Responsible modem industries, reflecting this heightened public and regulatory awareness, are either substituting benign materials for hazardous ones, or using hazardous materials only under carefully controlled conditions. In addition, present-day environmental consciousness dictates that we deal responsibly with legacy wastes. The decontamination and decommissioning (D&D) of facilities at which mercury was used or processed presents a variety of challenges. Elemental mercury is a liquid at room temperature and readily evaporates in air. In large mercury-laden buildings, droplets may evaporate from one area only to recondense in other cooler areas. The rate of evaporation is a function of humidity and temperature; consequently, different parts of a building may be sources ...

1994-08-18

135

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural ...

136

Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant  

International Nuclear Information System (INIS)

This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major ...

1987-01-01

137

Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major ...

1987-09-01

138

Managing system for mounted parts and spare parts of power source facilities  

Energy Technology Data Exchange (ETDEWEB)

The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted ...

1995-07-01

139

Reliability analysis for stiff versus flexible piping  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. We then investigated a couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design. We concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of ...

1985-11-01

141

PWR primary circuit piping installation of Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear power Plant are briefly described.

142

Overview of reliability test program on primary coolant piping of light water reactors  

Energy Technology Data Exchange (ETDEWEB)

Upon request by the Science and Technology Agency of Japanese Government, the Japan Atomic Energy Research Institute has conducted Piping Reliability Test Program to demonstrate the safety and reliability of light water reactor primary pipings. In this report, the results of the program are summarized. In the test program, pipe fatigue tests, Leak-Before-Break (LBB) verification tests and pipe rupture tests were carried out to examine the integrity of pipings, to verify the LBB concept and to demonstrate the effectiveness of the protective measures against jet impingement and pipe whip under pipe rupture event, respectively. In the pipe fatigue tests, a procedure to predict the fatigue crack growth was developed and the integrity of piping during plant service life was demonstrated. In the LBB ...

1993-10-01

143

AIR BREATHING DEVICE FOR PIPE LINE  

J-STORE (Japan)

Full Text Available

2004-11-29

144

Technical considerations for flexible piping design in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. The current study was conducted to establish the necessary groundwork based on the piping reliability analysis. A confirmatory piping reliability assessment indicated that removing rigid supports and snubbers tends to either improve or affect very little the piping reliability. A couple of changes to be implemented in Regulatory Guide (RG) 1.61 and RG 1.122 aimed at more flexible piping design were investigated. It was concluded that these changes substantially reduce calculated piping responses and allows piping redesigns with significant reduction in number of ...

1985-03-15

145

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

146

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

147

Pumping manual/7th edition  

Energy Technology Data Exchange (ETDEWEB)

This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.

1984-01-01

148

Oil and Natural Gas Technology: Development of Next Generation Multiphase Pipe Flow Prediction Tools. Final Report.  

Science.gov (United States)

The developments of fields in deep waters (5000 ft and more) is a common occurrence. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oil-and water possibly along with sand, hydrates, and wax...

2008-01-01

149

Monitoring drinking water networks by data telemanagement; Telegestion de datos para control de redes de agua potable  

Energy Technology Data Exchange (ETDEWEB)

The WIT telemanagement system simply, reliably and efficient by makes available to us in real time processed, ordered and managed data. Such information has been used to optimise the performance of the drinking water distribution networks on a number of housing estates. This has led to major saving in consumption and on equipment maintenance, thereby improving customer service and obtaining a more rational use of piped water. (Author)

1997-04-01

150

Methods of reducing magnetic field near the transmission lines  

International Nuclear Information System (INIS)

Due to biological effects of magnetic fields of high voltage transmission lines and induced effects on has pipe line, telecommunication system and interference with sensitive electronic equipment, many effort have been done to reduce transmission lines magnetic fields and several ideas have been introduced. In this paper we review three methods: phase split, shielded and compacted line methods. With aid of a developed software programme these methods are then applied to transmission lines and the results are analyzed.

2003-01-01

151

Leak location in fluid filled cables using the PFT method  

Energy Technology Data Exchange (ETDEWEB)

A new method of pinpointing dielectric fluid leaks on pipe-type and self-contained cables using perfluorocarbon tracer (PFT) is presented. The method has successfully been used on the Con Edison transmission system to locate leaks of dielectric fluid on both types of cables. Application of the PFT technique does not require feeder deenergization and provides major advantages over the conventional method of freeze and pressure testing. Description of the method and results of field application are presented in the paper.

1999-01-01

152

Hygiene in air pipes. Tasks and requirements on clean air devices; Hygiene in Luftleitungen. Aufgaben und Anforderungen an RLT-Anlagen  

Energy Technology Data Exchange (ETDEWEB)

Space HVAC systems are to provide hygienical room air. Air change is necessary because of pollutants released from materials or production processes but also because of the presence of humans or animals who consume oxygen. Poor room climate and/or poor air hygiene do not only reduce the felt comfort but may also result in a loss or profitability and higher sickness rates. (orig.)

2006-07-01

153

Development of Next Generation Multiphase Pipe Flow Prediction Tools. Semi-Annual Technical Report. Reporting Period: June 2006 through November 2006.  

Science.gov (United States)

The developments of oil and gas fields in deep waters (5000 ft and more) will become more common in the future. It is inevitable that production systems will operate under multiphase flow conditions (simultaneous flow of gas-oiland water possibly along wi...

2007-01-01

154

Low Frequency Phased Array Techniques for Crack Detection in Cast Austenitic Piping Welds: A Feasibility Study  

Energy Technology Data Exchange (ETDEWEB)

Studies conducted at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington have focused on developing and evaluating the reliability of nondestructive testing (NDT) approaches for coarse-grained stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (NRC) on the utility, effectiveness and limitation of NDT techniques as related to inservice testing of primary system piping components in pressurized water reactors. We examined cast stainless steel pipe specimens containing thermal and mechanical fatigue cracks located close to the weld roots and having inner and outer diameter surface geometrical conditions that simulate several water reactor primary piping configurations. In addition, segments of vintage centrifugally cast piping were examined to characterize the inherent acoustic ...

2007-01-01

155

Potential gas entry into FFTF after a postulated pipe rupture  

International Nuclear Information System (INIS)

... failures fftf reactor heat transfer hydraulics loss of coolant pipes primary coolant

156

Innovative coke oven gas cleaning system for retrofit applications. Quarterly technical progress report No. 4, October 1, 1990 to December 31, 1990  

Energy Technology Data Exchange (ETDEWEB)

Work on this coke oven gas cleaning demonstration project (CCT-II) this quarter has been focused on Phase IIB tasks, and include engineering, procurement, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. Engineering efforts are nearly complete. Remaining to be finalized is an assessment of electrical heat tracing/insulation needs for pipe lines, assessment of fire protection requirements, and instrument modifications. Procurement of all major equipment items is complete, except for possible additions to fire fighting capabilities. Major focus is on expediting pipe and structural steel to the project site. Civil construction is complete except for minor pads and bases as required for pipe supports, etc. Erection of the hydrogen sulfide and ammonia scrubber vessels is complete. Installation of scrubber vessel internals ...

1993-10-22

157

Application of LBB to high energy pipings of PWR in Korea  

Energy Technology Data Exchange (ETDEWEB)

The application of the LBB technology to the newly constructed PWRs has been approved in Korea for several high energy systems that can meet rigorous acceptance criteria. The LBB evaluation had been initiated for Yong-Gwang 3 and 4 units (YGN 3 and 4) which are in service, and subsequently performed for Ul-Chin 3 and 4 units (UCN 3 and 4) which are in construction. The LBB application in Korea is based on the USNRC requirements. The LBB evaluation for YGN 3 and 4 is to eliminate the dynamic effects associated with the postulated DEGB from design basis loads as well as to eliminate pipe whip restraints and jet impingement barriers. There were several issues on the application of LBB to the primary coolant loop and the pressurizer surge line. Of concern were material properties of carbon steel for the primary coolant loop, estimation of crack opening area at the pipe-to-nozzle interface considering the asymmetry, and the ...

1996-12-31

158

Achievement report in fiscal 2000. Model project to reduce electric power consumption at cement burning plant; 2000 nendo seika hokoku. Semento shosei plant denryoku shohi sakugen model jigyo  

Energy Technology Data Exchange (ETDEWEB)

In order to serve for efficient energy utilization and environmental improvement in the Republic of Vietnam, a 'Model project to reduce electric power consumption at cement burning plant' has been implemented. This paper summarizes the achievements. This project is intended to add an advanced, matured and reliable electric power generation facility using cement waste heat to the existing cement plant in Vietnam to produce steam and generate power by utilizing the waste heat generated from the preheating process in the burning plant. The present project has performed the detailed designing on the piping, electric facilities and instrumentation based on the basic agreement on the project. Fabrication of the piping has been executed by the Vietnam side. Valves and electric devices were procured and transported, including those fabricated in the previous fiscal year. Technology guiding ...

2002-03-01

159

Device for the inspection of curved pipes in steam raising units  

Energy Technology Data Exchange (ETDEWEB)

The chain of eddy current probes and a film cassette probe, which responds to radiation from a radio-active source in one of the heat exchanger pipes is examined. The probes are moved by nylon pipes on both ends of the chain through the pipe to be examined. The nylon pipes are bent off load. In this way the probes on the chain will adjust near to the plane of bending of the pipes to be tested.

1980-01-03

160

Sensor test facilities and capabilities at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced ...

1996-12-31

161

Cavitation guide for control valves  

Energy Technology Data Exchange (ETDEWEB)

This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the ...

1993-04-01

162

The PANDA facility and first test results  

International Nuclear Information System (INIS)

The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport ...

163

Risk evaluation system for facility safeguards and security planning  

International Nuclear Information System (INIS)

The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planning assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily.

1987-07-12

164

Low-level and transuranic waste transportation, disposal, and facility decommissioning cost sensitivity analysis  

Energy Technology Data Exchange (ETDEWEB)

The Systems Design Study (SDS) identified technologies available for the remediation of low-level and transuranic waste stored at the Radioactive Waste Management Complex's Subsurface Disposal Area at the Idaho National Engineering Laboratory. The SDS study intentionally omitted the costs of transportation and disposal of the processed waste and the cost of decommissioning the processing facility. This report provides a follow-on analysis of the SDS to explore the basis for life-cycle cost segments of transportation, disposal, and facility decommissioning; to determine the sensitivity of the cost segments; and to quantify the life-cycle costs of the 10 ex situ concepts of the Systems Design Study.

1992-05-01

165

Low-level and transuranic waste transportation, disposal, and facility decommissioning cost sensitivity analysis  

Energy Technology Data Exchange (ETDEWEB)

The Systems Design Study (SDS) identified technologies available for the remediation of low-level and transuranic waste stored at the Radioactive Waste Management Complex`s Subsurface Disposal Area at the Idaho National Engineering Laboratory. The SDS study intentionally omitted the costs of transportation and disposal of the processed waste and the cost of decommissioning the processing facility. This report provides a follow-on analysis of the SDS to explore the basis for life-cycle cost segments of transportation, disposal, and facility decommissioning; to determine the sensitivity of the cost segments; and to quantify the life-cycle costs of the 10 ex situ concepts of the Systems Design Study.

1992-05-01

166

Results of reliability test program on light water reactor piping  

Energy Technology Data Exchange (ETDEWEB)

The Japan Atomic Energy Research Institute has conducted a piping reliability test program to demonstrate the safety and reliability of light water reactor primary piping. In this program, pipe fatigue test, leak-before-break (LBB) verification test and pipe rupture test were carried out to examine the integrity of piping, to verify the LBB and to demonstrate the effectiveness of protective measures against jet impingement and pipe whip loads under a pipe rupture event.In the pipe fatigue test, a procedure to predict the fatigue crack growth was developed, and the integrity of piping during the plant service life was evaluated. In the LBB verification test, the pipe fracture test and the leak rate test were performed to verify the LBB in the primary piping.In ...

1994-12-01

167

Waste monitoring system for effluents  

Energy Technology Data Exchange (ETDEWEB)

The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.

1995-07-01

168

Radionuclide buildup in FFTF [Fast Flux Test Facility] heat transport system cells  

International Nuclear Information System (INIS)

The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.

1989-11-26

169

Decree of the Czechoslovak Atomic Energy Commission No. 436/1990 on quality assurance of selected facilities with respect to nuclear safety of nuclear facilities  

International Nuclear Information System (INIS)

The Decree specifies basic quality assurance requirements applicable to machines, their parts and materials, civil engineering structures, means for automated control of technological processes including hardware and software, and electricity supply systems related to nuclear safety of nuclear facilities, and stipulates binding procedures for the implementation of technical and organizational provisions associated with the quality of selected equipment to ensure nuclear safety of nuclear facilities. Safety classes are defined for selected equipment. Requirements laid on safety assurance documentation are specified, and requirements placed on safety assurance programmes, their preparation, finalization and approval are defined. Quality assurance requirements are also specified with respect to the designing, manufacture, construction, operation, repair, modification and decommissioning of nuclear ...

1995-02-01

170

Reliability analysis of stiff versus flexible piping. Final project report  

Energy Technology Data Exchange (ETDEWEB)

This research project is to develop a technical basis for flexible piping designs which will improve piping reliability and minimize the use of pipe supports, snubbers, and pipe whip restraints. This study indicated that piping design can be made more reliable by some reduction of rigid supports and/or snubbers. This study also confirmed that the malfunction of pipe whip restraints introduced higher thermal stresses and tended to reduce the overall piping reliability. Finally, our results indicated that supports in a flexible piping design may need to be reevaluated and that the elimination of pipe supports which are close to components should be done with care in order to minimize the impact on the component reliability.

1985-05-01

171

Wax and hydrate control with electrical power  

Energy Technology Data Exchange (ETDEWEB)

Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the gas/water phase may freeze ...

1997-08-01

172

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

173

Increasing concentrations of trihalomethanes (THMs) in a drinking water distribution network; Trihalometanos (THMs) en una red de distribucion de agua potable en alta  

Energy Technology Data Exchange (ETDEWEB)

THMs are disinfection by-products (DBPs) generated during water chlorination. Concentration of individual and total THMs, depends on treatment process and THMs precursors level. ATLL water utility has two DWTP (Llobregar and Ter) that produce and supply drinking water to Barcelona and regional area. This work studies the levels of THMs along the ATLL distribution system (450 km). Although, no differences were observed along water pipes system, changes of water resource and mix procedures were related. (Author) 12 refs.

1999-07-01

174

Analysis and evaluation for little branch of Daya Bay Nuclear Power Station based on vibration test result  

International Nuclear Information System (INIS)

During the operation of Daya Bay Nuclear Power Station, some little branches of secondary system were with great vibration and even some of them cracked due to the great vibration that may cause some effect on the safety of the power station. This paper performed analysis and evaluation to the eight systems of Daya Bay Nuclear Power Station based on the vibration test results from the examination of the safety during ten years, and the list of the sensitive piping and suggestion for modification were presented based on the analysis results. (authors)

2007-06-01

175

Ampacity calculations for mixed underground cable systems in the same ductbank  

Energy Technology Data Exchange (ETDEWEB)

The steady state ampacity is calculated for mixed electric power underground cable circuits in a single trench or ductbank. The methodology presented in this paper can be applied to any practical number of balanced, three phase circuits (each in trefoil, pipe or conduit) of different voltage classes, cable sizes, load currents and cable systems to located anywhere within a single trench or ductbank. The different thermal resistivities of the backfill or ductbank and the surrounding soil are taken into consideration. A practical example for 10 circuits in a trench is provided.

1994-12-31

176

ETE-EVAL: a methodology for D and D cost estimation  

International Nuclear Information System (INIS)

In compliance with Article 20 of the sustainable radioactive materials and waste management act dated 28 June 2006, the CEA and AREVA are required every three years to revise the cost of decommissioning their facilities and to provide the necessary assets by constituting a dedicated fund. For the 2007 revision the CEA used ETE-EVAL V5. Similarly, AREVA reevaluated the cost of decontaminating and dismantling its facilities at La Hague, as the previous estimate in 2004 did not take into account the complete cleanup of all the structural work. ETE-EVAL V5 is a computer application designed to estimate the cost of decontamination and dismantling of basic nuclear installations (INB). It has been qualified by Bureau Veritas and audited. ETE-EVAL V5 has become the official software for cost assessment of CEA civilian and AREVA decommissioning projects. It has been used by the DPAD (Decontamination and Dismantling Projects Department) cost assessment ...

177

Structural integrity of whipping pipes following a postulated circumferential break - a contribution to determining strain levels acceptable under faulted conditions  

Energy Technology Data Exchange (ETDEWEB)

It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)

1993-10-01

178

Augmentation of radiative heat transfer in an infinite cylindrical pipe enclosing a participating gas  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a gray gas, the augmentation observed are negligible. For the range of values studied ...

1992-10-01

179

The first PANDA tests  

International Nuclear Information System (INIS)

The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be favorably responsive and ...

180

Problems and solutions of the IFSMTF power and switch system  

Energy Technology Data Exchange (ETDEWEB)

Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.

1985-01-01

181

New neutron simulation capabilities provided by the Sandia Pulse Reactor (SPR-III) and the Upgraded Annular Core Pulse Reactor (ACPR)  

Science.gov (United States)

The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which ...

1978-07-01

182

Piping response testing associated with pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

EPRI has sponsored an experimental program in the pipe whip impact and pipe rupture and depressurization areas. Sixteen pipe whip tests were performed with 3 in Schedule 80 (or 10) carbon steel pipes impacting on rigid target or concrete slab. The major testing parameters include distance, impact location, pipe rupture location, and concrete slab thickness and strength. The piping crushing at impact correlates with impact force and target response behavior. Conservatism was established by comparing measured and calculated impact forces. The pipe rupture and depressurization tests were carried out using 6 in stainless steel and carbon steel pipes under either PWR or BWR fluid conditions. These tests are of axial crack with initial machined-in surface flaw. It was found that pipe rupture would occur ...

1985-11-01

183

Pipe whip studies  

Energy Technology Data Exchange (ETDEWEB)

An experimental and analytical study was performed to improve understanding of the dynamic impact behavior of carbon steel pipes. The test program addressed two types of pipe impact scenarios using both 2- and 4-in. Sch-80 pipes and elbows. Projectile-on-pipe tests simulated the behavior of a stationary target pipe which is impacted at its center by a larger, more rigid whipping pipe. These target pipes, which contained non-flowing water at about 290{degree}C temperature and ca 8.5 megapascals pressure, exhibited a peak deformation of up to 45% reduction in their diameter. For each test condition, the local deformation at the impact zone is a function of the peak impact force and impact velocity. Pipe-on-wall tests simulated the impact of an elbow at the free end of a cantilevered whipping pipe with ...

1984-06-01

184

Determination of critical length for pipe whip design  

Energy Technology Data Exchange (ETDEWEB)

Design of pipe whip restraints requires a knowledge of the maximum allowable unsupported pipe length. This paper presents a numerical method for calculating this critical length of the pipe. Salient features of the method are: (1) as a flow rounds an elbow, it exerts a transverse kick and an axial thrust to the pipe, both the axial thrust and the bending moment are considered; (2) the jet force is applied in an abrupt manner, the dynamic amplification factor (DAF) is determined from the load-deflection (H-{Delta}) curve of the pipe, by taking into consideration large strain, large deformation and the nonlinear stress-strain relationship of the piping material; (3) the ultimate capacity of the pipe under the combined action of an axial force and a bending moment is governed by an interaction formula. The maximum unsupported ...

1995-11-01

185

Maintenance implementation plan for T Plant. Revision 2  

Energy Technology Data Exchange (ETDEWEB)

This document is a Maintenance Implementation Plan (MIP) for the T Plant Facility complex located in the 200 West Area of the Hanford Reservation in Washington state. This plan has been developed to provide a disciplined approach to maintenance functions and to describe how the T Plant facility will implement and comply with the regulations according to US DOE order 4330.4B, entitled Maintenance Management Program, Chapter 2.0 {open_quotes}Nuclear Facilities{close_quotes}. Physical structures, systems, processes, as well as all associated equipment specifically assigned to these groups are included in the MIP.

1995-05-01

186

Facility Safety Plan B360 Complex Biohazardous Operations CMLS-412r0  

Science.gov (United States)

This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.

2007-01-08

187

Users' guide on socket heat fusion joining of polyethylene gas pipes. Volume 1. Topical report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact ...

1991-03-01

188

Technical reference on socket heat fusion joining of polyethylene gas pipes. Volume 2. Topical Report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact ...

1991-03-01

189

Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C  

Energy Technology Data Exchange (ETDEWEB)

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these ...

2009-11-01

190

Demonstration of piping integrity with SMA technology  

Energy Technology Data Exchange (ETDEWEB)

The safe function of a new pipe whip restraint device has been demonstrated in a full scale test. The restraint is based on using a shape memory alloy to protect a pipe and its environment in the event of a double-ended-guillotine-break. The evaluation test has been performed at boiling water reactor (BWR) operating pressure and temperature using a pipe representing BWR primary piping. (orig.) 2 refs.

1997-10-01

191

Shutdown Chemistry Process Development for PWR Primary System  

Energy Technology Data Exchange (ETDEWEB)

This study report presents the shutdown chemistry of PWR primary system to reduce and remove the radioactive corrosion products which were deposited on the nuclear fuel rods surface and the outside of core like steam generator channel head, RCS pipings etc. The major research results are the follows ; the deposition radioactive mechanism of corrosion products, the radiochemical composition, the condition of coolant chemistry to promote the dissolution of radioactive cobalt and nickel ferrite, the control method of dissolved hydrogen concentration in the coolant by the mechanical and chemical methods. The another part of study is to investigate the removal characteristics of corrosion product ions and particles by the demineralization system to suggest the method which the system could be operate effectively in shut-down purification period. (author). 19 refs., 25 figs., 48 tabs.

1997-12-31

192

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

193

Southern receiver system: Environmental impact assessment status report: Conawapa to Winnipeg Power Transmission Complex  

Energy Technology Data Exchange (ETDEWEB)

The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.

1992-01-01

194

Information on Hanford site cribs and septic systems  

Energy Technology Data Exchange (ETDEWEB)

This document provides information on septic systems with a design capacity of greater than 14,500 gal/d and cribs submitted as requested by the Washington State Department of Ecology. Data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. Information concerning the deactivation method for a facility is included when such information is available.

1988-05-01

195

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other ...

1990-03-01

196

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried ...

1988-01-01

197

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried ...

1988-08-01

198

Evaluation of heat exchange rate of GHE in geothermal heat pump systems  

Energy Technology Data Exchange (ETDEWEB)

Total thermal resistance of ground heat exchanger (GHE) is comprised of that of the soil and inside the borehole. The thermal resistance of soil can be calculated using the linear source theory and cylindrical source theory, while that inside the borehole is more complicated due to the integrated resistance of fluid convection, and the conduction through pipe and grout. Present study evaluates heat exchange rate per depth of GHE by calculating the total thermal resistance, and compares different methods to analyze their similarities and differences for engineering applications. The effects of seven separate factors, running time, shank spacing, depth of borehole, velocity in the pipe, thermal conductivity of grout, inlet temperature and soil type, on the thermal resistance and heat exchange rate are analyzed. Experimental data from several real geothermal heat pump (GHP) applications in Shanghai are used to validate the present calculations. ...

2009-12-15

199

Self installable: floating production facility requires only light support craft  

Energy Technology Data Exchange (ETDEWEB)

An integrated multiwell floating production, storage, and offloading (FPSO) facility was successfully installed at the Tazerka field offshore Tunisia in 1982. Because there is good reason to believe that the installation techniques developed for the Tazerka FPSO can be applied to even larger systems in deeper waters, this paper presents the design and step-by-step installation procedures developed at Tazerka.

1983-05-01

200

Quality assurance requirements for the design of nuclear fuel reprocessing facilities  

International Nuclear Information System (INIS)

Requirements and guidance are provided for a quality assurance program for the design of nuclear fuel reprocessing facilities involving structures, systems and components whose satisfactory performance is required to prevent accidents that could cause undue risk to the health and safety of the public, or to mitigate the consequences of such accidents if they were to occur. The standard is to be used in conjunction with ANSI N46.2.

201

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

202

Offshore: North Sea facility gets the CETCO solution  

British Library Electronic Table of Contents (United Kingdom)

CETCO Oilfield Services, suppliers of environmental systems, have undertaken a project to treat contaminated water returns on a Floating, Production, Storage and Offloading (FPSO) facility in the North Sea. The solution sees fluids treated during oil well clean-up operations, reducing the potential for overboard oil discharges, and resulting production upsets.

2006-01-01

203

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

204

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

205

Green design focus: Energy efficiency and environmental responsibility  

Energy Technology Data Exchange (ETDEWEB)

This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.

1998-02-01

206

Drilling on the basis of reliable data. Geothermal exploration; Bohren nach verlaesslichen Planungsdaten. Geothermie  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)

2008-01-15

207

B Plant treatment, storage, and disposal (TSD) units inspection plan  

Energy Technology Data Exchange (ETDEWEB)

This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under ...

1996-04-26

208

Modeling of feed water check valves using RELAP5; Modellierung von Speisewasserrueckschlagventilen in RELAP5  

Energy Technology Data Exchange (ETDEWEB)

Westinghouse Electric Germany GmbH has developed fluid dynamic models for medium-actuated armatures using the thermal hydraulic code RELAP5 in order to reach a more realistic description of the armature behavior including fluid-structure interactions in case of transient flow conditions in piping systems. The contribution is concerned with the modeling of damped check valves. The model allows the description of the behavior during opening and closure of a check armature. The calculated results show good agreement with the available measured data.

2009-07-01

209

Focus on O & M  

Energy Technology Data Exchange (ETDEWEB)

A series of short articles discusses: use of a chemically bonded ceramic composite liner, WellerDensit, to protect the steel surface of pulverizer classifier cones; use of a fused cast basalt liners developed by Abresist Corp. in pipes for transporting coal and ash; a survey completed by the National Energy Technology Laboratory to identify causes of outages and other concerns expressed by PC and FBC boiler operators; and Temp-Age, Early Visc-Age and Modern Visc-Age systems for controlling the viscosity of heavy fuel oil to maintain proper combustion. 7 figs.

2004-10-01

210

Axiomatic Design Approach for a Reactor Head Structure Assembly  

Energy Technology Data Exchange (ETDEWEB)

Korea Atomic Energy Research Institute (KAERI) has been developing the integral reactor. The reactor head structure assembly (RHSA) is the structure installed over the reactor cover. Due to the characteristics of an integral reactor, there are many instrument cables and power cables coming out from the reactor cover and main components. The RHSA provides an interface location to connect these cables from Architecture Engineer (AE) and System Designer (SD). It also prevents a pipe whip and it prohibits instruments from becoming missiles. In this research, the axiomatic design approach for the RHSA is performed.

2006-07-01

211

Status of PACTEL facility  

Energy Technology Data Exchange (ETDEWEB)

Since 1976, the Nuclear Engineering Laboratory of the Technical Research Centre of Finland and Lappeenranta University of Technology have cooperated in the field of nuclear reactor thermal-hydraulics. During these years, a series of experimental facilities (REWET-I, -II, -III, VEERA) simulating pressurized water reactors (PWRs) have been built. The newest facility, PACTEL (Parallel Channel Test Loop), is an experimental out-of-pile facility designed to simulate the major components and system behaviour of a commercial PWR during postulated small and medium size break loss-of-coolant accidents (LOCAs), natural circulation and operational transients. A PACTEL natural circulation experiment has been carried out as an OECD/NEA international standard problem ISP 33. (2 refs., 3 figs., 2 tabs.).

1993-12-31

212

Hot Cell Facility (HCF) Safety Analysis Report  

Energy Technology Data Exchange (ETDEWEB)

This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important safety functions of each SSC are described. Additionally, information which ...

2000-11-01

213

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) ...

1990-07-01

214

Performance of Buried Pipe Installations, Summary.  

Science.gov (United States)

The goal of this research project was to determine the eff ects of geometric and mechanical parameters characterizing the soil-structure interaction developed in a buried pipe installation. Parameters such as pipe ring stiff ness, bedding thickness, trenc...

2010-01-01

215

Method of pipe whip and impact analyses  

Energy Technology Data Exchange (ETDEWEB)

We successfully reproduce one of the French pipe whip experiments with the computer code WIPS. The WIPS results are in excellent agreement with the experimental data and the French computer code TEDEL. This justifies the use of its pipe element in conjunction with its U-bar element in a simplified method of impact analyses.

1983-11-21

216

Burner for rotary kiln; Braender til roteroven samt fremgangsmaade til dannelse af en braenderflamme med braenderen  

Energy Technology Data Exchange (ETDEWEB)

Burner for feeding a solid and a liquid or gaseous fuel to a kiln comprises a central supply pipe for liquid or gas surrounded concentrically by a first pipe providing an annular passage through which primary air is supplied. Concentrically surrounding that pipe is a second pipe providing an annular channel for supply of solid fuel in carrier air stream. The outlet end of the first concentric pipe is closed by a plate fixed mounted at the pipe end and providing multiple nozzles having their axes parallel to the burner axis. The surface of the plate facing the burning zone provides a divergence opening for the central pipe while the inner surface is formed with helical teeth. These are engaged by complementary teeth mounted on the end of the central pipe which is rotatable and biased by springs so that the teeth are in ...

1994-10-31

217

Maintenance implementation plan for the B Plant/WESF. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the B Plant/WESF (Waste Encapsulation Storage Facility) complex. The objective of this plan is to provide baseline information for establishing and identifying WHC conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at B Plant/WESF. The B Plant WESF facility complex consists of three main facilities and several support structures located in the 200 East Area of the Hanford site. B Plant is a transition facility that is required to ensure safe storage and management of WESF (operating facility) cesium and strontium capsules. B Plant/WESF also contains substantial radiological inventory from previous campaigns. ...

1996-01-01

218

System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate  

Energy Technology Data Exchange (ETDEWEB)

Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.

1989-08-01

219

Design on SDS2 on-line poison concentration monitoring in CANDU  

Energy Technology Data Exchange (ETDEWEB)

At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).

1996-10-01

220

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be ...

1983-08-26

221

Bioreactors  

Energy Technology Data Exchange (ETDEWEB)

Composting is once again gaining interest among ecological engineers in view of greener industrial and residential activities. Uniform composting is needed to ensure decomposition and to keep the whole system at the same composting stage. A homogeneous temperature must be maintained throughout the media. A bioreactor design consisting of a heater core made of copper tubing was designed and tested. Two four-inch holes were made at the top and bottom of the barrel to allow air to flow through the system and promote aerobic composting. Once composting began and temperature increased, the water began to flow through the copper piping and the core heat was distributed throughout the medium. Three thermocouples were inserted at different heights on a 200 litre plastic barrel fitted with the aforementioned apparatus. Temperature variations were found to be considerably lower when the apparatus was operated with the heat ...

2010-07-01

222

Nonlinear dynamic analysis of high energy line pipe whip  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a nonlinear dynamic analysis of TVA high energy line pipe whip tests using the ABAQUS-EPGEN code. The analysis considers the effects of large deformation and strain rate on resisting moment and energy absorption capability. The numerical results of impact forces, impact velocities, pipe strains, and reaction forces at pipe supports are compared to the TVA test data. The calculated pipe whip impact time and forces are also compared with those predicted using current industry practice. The calculated pipe support reaction forces are found to be in good agreement with the TVA test data except for some peak values at the very beginning of the pipe break. These peaks are believed to be due to stress wave propagation which cannot be addressed by the ABAQUS code. Both elbow crushing and strain rate have been approximately simulated. The effects are ...

1984-02-01

223

Multiple-Purpose Project, Little Blue River Basis East Fork ...  

Science.gov (United States)

... 146 27 1 Aug 83, outlet works excavation. Sewer pipe installation. ... No. 157. Outlet works excavation. Sewer pipe installation. ...

1990-09-01

224

Analytical studies of four-inch pipe whip tests under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

The purpose of pipe rupture studies in JAERI is to perform model tests on pipe whip, restraint behavior, jet impingement and jet thrust force, and to establish a computational method for analyzing these phenomena. This report presents the analytical results of 4-inch pipe whip tests under BWR LOCA conditions. Dynamic response analyses were performed using the general-purpose finite element program ADINA. The test pipe was modelled by straight beam elements and the four restraints were modelled by a single truss element. The analytical results were compared with the experimental results. Impact time and maximum total restraint force showed good agreement with experimental results. On the other hand, pipe strain and pipe deflection could not be predicted so well. The reason for this is that the sliding of the restraint during the pipe whip ...

1985-01-01

225

Waste Handeling Building Conceptual Study  

Energy Technology Data Exchange (ETDEWEB)

The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options ...

2000-11-06

226

Utility of Recycled Bedding for Laboratory Rodents  

UK PubMed Central (United Kingdom)

Animal facilities generate a large amount of used bedding containing excrement as medical waste. We developed a recycling system for used bedding that involves soft hydrothermal processing. In this...Full Text Available

2009-07-01

227

Developing a Performance Measurement Framework and Indicators for Community Health Service Facilities in Urban China  

UK PubMed Central (United Kingdom)

BackgroundChina has had no effective and systematic information system to provide guidance for strengthening PHC (Primary Health Care) or account to citizens on progress. We report...Full Text Available

228

Emergency reactor core cooling device  

International Nuclear Information System (INIS)

The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of ...

1993-03-16

229

Achievement report for fiscal 1998. Research and development of a multi-plant maintenance system (the first year); 1998 nendo seika hokokusho. Odanteki maintenance gijutsu no kenkyu kaihatsu (dai 1 nendo)  

Energy Technology Data Exchange (ETDEWEB)

This research and development is intended to structure a network centering around a center having systematized high-level maintenance technology, by utilizing the technological infrastructure having been built in local areas, together with element technologies possessed by national and private research institutes, universities and colleges. It is also purposed to establish a new industrial system for maintenance to realize high reliability, high operation rate and low cost in plants in certain areas. The present fiscal year had the following achievements: research and development of a maintenance system, a maintenance model, a maintenance vehicle, damage estimating technology for stationary parts such as piping, an anomaly diagnostic system using acoustic emission, an anomaly diagnostic system using wear particles in lubricant, an anti-wear material using surface modification, a ...

1999-03-01

230

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

231

Estimating the tritiated hydrocarbon decontamination factor by heavy methane  

International Nuclear Information System (INIS)

As part of the start up of Los Alamos National Laboratory's new tritium-handling facility, the efficiency of a catalytic oxidation tritium decontamination system was investigated using deuterated methane. The tests were performed during the start up of the facility to confirm the operability of the system before introducing tritium and to provide a baseline for comparison. Techniques and instruments normally used for atmospheric tracer experiments using deuterated methane were applied virtually without modification. The sensitivity of this method allowed preliminary checks at the sub-ppm (v/v) level.

232

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

233

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

234

Acceptance test report for the Westinghouse 100 ton hydraulic trailer  

Energy Technology Data Exchange (ETDEWEB)

The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.

1995-03-06

235

Navy Occupational Health Information Management System (NOHIMS). Hazardous Materials Control Module. Users' manual  

Energy Technology Data Exchange (ETDEWEB)

The Hazardous Materials Control Module (HMC) is one module of four for the Industrial Health component. The HMC module was designed to inform employees of health and safety hazards in the workplace and to track the movement of hazardous materials through the facility. The module performs these functions by maintaining health and safety data on hazardous materials used in the facility, and by tracking who requests information about any hazardous materials. The HMC module gets its information from two sources. The first one is the Hazardous Materials Information System (HMIS), this is a national system that is used by the Department of Defense. It is loaded on to the system via tapes that contain all safety, health and transportation information about a particular product. The second is Material Safety Data Sheets (MSDS) that are procured by a particular site. This information is ...

1987-01-16

236

The PANDA tests for SBWR certification  

International Nuclear Information System (INIS)

The ALPHA project is centered around the experimental and analytical investigation of the long-term decay heat removal from the containments of the next generation of open-quotes passiveclose quotes ALWRs. The project includes integral system tests in the large-scale (1:25 in volume) PANDA facility as well as several other series of tests and supporting analytical work. The first series of experiments to be conducted in PANDA have become a required experimental element in the certification process for the General Electric Simplified Boiling Water Reactor (SBWR). The PANDA general experimental philosophy, facility design, scaling, and instrumentation are described. Steady-state PCCS condenser performance tests and extensive facility characterization tests were already conducted. The transient system behavior tests are underway; preliminary results from the first transient test M3 are ...

1996-03-01

237

Development of in-vessel reflood instrumentation at ORNL  

International Nuclear Information System (INIS)

A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument ...

2004-09-06

238

Application of probabilistic methods to accident analysis at waste management facilities  

International Nuclear Information System (INIS)

Probabilistic risk assessment is a technique used to systematically analyze complex technical systems, such as nuclear waste management facilities, in order to identify and measure their public health, environmental, and economic risks. Probabilistic techniques have been utilized at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, to evaluate the probability of a catastrophic waste hoist accident. A probability model was developed to represent the hoisting system, and fault trees were constructed to identify potential sequences of events that could result in a hoist accident. Quantification of the fault trees using statistics compiled by the Mine Safety and Health Administration (MSHA) indicated that the annual probability of a catastrophic hoist accident at WIPP is less than one in 60 million. This result allowed classification of a catastrophic hoist accident as ''not credible'' at WIPP per DOE ...

239

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the ...

2004-07-01

240

A model for the calculation of vent clearing transients in pressure suppression systems  

International Nuclear Information System (INIS)

For the layout of a pressure suppression system of a light water cooled reactor (boiling water reactor) it is important to know the time dependent behavior of the vent clearing transient after a loss-of-coolant accident for two main reasons: time of the end of the vent clearing transient influences strongly the pressure and temperature maxima in the drywell and wetwell. Time-dependent behavior of the vent clearing transient influences pressure loads in the condensation pool of the wetwell and therefore pressure induced stresses to the structure. The time-dependent behavior of the water masses in the vent pipes and wetwell are described by the basic equations for a nonstationary incompressible friction flow: momentum equation, continuity equation and a correlation for the variation of the state of the gas volume in the wetwell above the water level. After many algebraic operations and integrations along the flow path, a single ordinary nonlinear ...

1975-09-01

241

Finite element analysis of pipe whip restraint behavior under jet thrust forces  

International Nuclear Information System (INIS)

Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to design the pipe whip restraints properly and/or to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various types of finite elements in ANSYS, the general purpose finite element computer grogram, was used to simulate the postulated pipe whips to obtain impact loads and the calculted results were compared with the specific experimental results from the sample pipe whip test for the U-chaped pipe whip restraints. Some calculational models, ...

242

Experimental studies of pipe whip and impact: Final report  

Energy Technology Data Exchange (ETDEWEB)

An experimental and computational study was undertaken to estimate the effects of pipe rupture and induced pipe whip impact on surround structures considered either as rigid or deformative such as concrete slabs. This program included sixteen tests using 3 inch schedule 80 (or 10) pipes made of carbon steel similar to A106 grade B. The study consisted of tests on rigid target and on concrete slab. The investigation of whip phase and impact phase was done separately for each test. For pipe impact on rigid targets, the impact forces are found to be directly related to the crush strength of the pipe and the general pipe deformation following the impact. For pipe impact on concrete slabs, the response of the target to the pipe impact needs to take into account the local effect such as penetration and localized damage on the ...

1987-02-01

243

Natural gas pipeline safety in residential areas served by master meters. a handbook  

Science.gov (United States)

Prepared to make housing project managers, maintenance engineering staff, and designers and architects of HUD - assisted and HUD - insured housing projects and mobile home parks aware of their responsibilities under the Natural Gas Pipeline Safety Act, this handbook provides technical guidance for the reduction of gas leaks and the handling of gas leak incidents in residential areas. The hazards of natural gas, concern over gas safety in residential areas, applicable codes and standards, and sources of information and help are reviewed, along with maintenance and engineering considerations relating to gas pipe failures, the detection of gas leaks, appliance servicing, and pipe installation, repair, and replacement. Housing management considerations are also examined, with attention to recordkeeping and reporting, emergency contingency planning, tenant education, staff qualifications and training, and the development and use of a maintenance and ...

1975-04-01

244

Corrosion failure and its prevention in light water reactor power plants  

Energy Technology Data Exchange (ETDEWEB)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

1988-01-01

245

Corrosion failure and its prevention in light water reactor power plants  

International Nuclear Information System (INIS)

During 17 years since the start of operation of the first commercial LWR in Japan, many LWRs have experienced various corrosion damages, but the causes of them were clarified, and the counter-measures were executed effectively in actual plants, as the results, the cause of corrosion damage decreased remarkably, and now, the high rate of operation has become to be maintained. In this paper, the major cases of corrosion damage experienced in LWRs in Japan and foreign countries, the causes of them and the countermeasures, the problems of hereafter and so on are described. The corrosion damage of metallic materials in the environment of LWRs occurs in the parts in contact with high temperature, high pressure water and steam, such as stainless steel piping in the primary cooling system of BWRs, and nickel alloy heating tubes of steam generators, carbon steel feed water piping and zirconium alloy fuel cladding tubes in PWRs. ...

246

Binary heat pump system. Binary heat pump system  

Energy Technology Data Exchange (ETDEWEB)

This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This system is characterized by the simultaneous operation of cooling and heating, high efficiency, high energy saving, high reliability of ...

1993-11-30

247

Work plan for the Isotopes Facilities Deactivation Project at Oak Ridge National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the Isotopes Facilities Deactivation Project (IFDP) is to place former isotopes production facilities at the Oak Ridge National Laboratory in a safe, stable, and environmentally sound condition; suitable for an extended period of minimum surveillance and maintenance (S&M) and as quickly and economical as possible. Implementation and completion of the deactivation project will further reduce the risks to the environment and to public safety and health. Furthermore, completion of the project will result in significant S&M cost savings in future years. The IFDP work plan defines the project schedule, the cost estimate, and the technical approach for the project. A companion document, the IFDP management plan, has been prepared to document the project objectives, define organizational relationships and responsibilities, and outline the management control systems to be employed in the management of the ...

1995-05-01

248

Development of a survey-design support sytem using soil data base; Doshitsu data base wo mochiita chosa sekkei shien system no kaihatsu ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as power plants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this ...

1994-09-05

249

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main ...

2010-11-15

250

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

International Nuclear Information System (INIS)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main ...

2010-11-01

251

Information technology security at the Advanced Photon Source  

International Nuclear Information System (INIS)

The proliferation of 'botnets,' phishing schemes, denial-of-service attacks, root kits, and other cyber attack schemes designed to capture a system or network creates a climate of concern for system administrators, especially for those managing accelerator and large experimental-physics facilities, as they are very public targets. This paper will describe the steps being taken at the Advanced Photon Source (APS) to protect the infrastructure of the overall network with emphasis on security for the APS control system.

2007-10-15

252

Design and procurement report for the FFTF fuel handling systems bottom-loading transfer cask  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) bottom-loading transfer cask (BLTC) system is designed to provide ex-vessel fuel transfers of irradiated reactor components between the reactor containment building and the LMFBR shipping cask in the reactor service building. This system is being procured from National Lead Industries, Wilmington, Delaware, under management of Aerojet Manufacturing Company.

1975-11-16

253

Influence of performance characteristic of a gaseous fuel supply system on hydrocarbon emissions of a dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

The performance of the gaseous fuel supply and its influence on hydrocarbon (HC) emissions of dual-fuel engines have been investigated. A new design of manifold respirators with mixers is also presented in the paper. The design of the gaseous fuel supply system has a great influence on HC emissions in the dual-fuel engine at light load. The problem of scavenging is discussed and solved by using the manifold respirators in the dual-fuel engine. It performs the function of retarding the gaseous fuel entry timing from the moment of intake valve opening, and its delaying effects have been measured and tested. Experimental results show that the manifold respirator gives the best performance in reducing HC emissions compared with a common pipe mixer and a respirator with bo miser. In addition, the mixing effects are sensitive to the mixer configuration. (Author)

2000-11-01

254

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

255

Full-scale model of cooling and heating system for JT-60 vacuum vessel  

Science.gov (United States)

A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature regulation.

1981-01-01

256

Field results using measurement-while-drilling directional systems in Long Beach, California  

Energy Technology Data Exchange (ETDEWEB)

One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.

1981-01-01

257

Preliminary study of the effect of pumped-storage plant operation on zooplankton  

Energy Technology Data Exchange (ETDEWEB)

The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into pumped-storage facilities at high levels, and then release this water during daytime ...

1980-01-01

258

Determination of parameters of the environment for equipment qualification at the Dukovany NPP. Post-accident parameters on the +14.7 m floor. Operating parameters on the +14.7 m floor and in the hermetic zone. Rev. 4  

International Nuclear Information System (INIS)

A detailed outline of the application of the MELCOR and RELAP5/MOD3.1 codes to the analysis of the thermohydraulic response and determination of other parameters of the medium on the floor is given for several classes of secondary coolant circuit accidents along with the description of the related facilities. An overview is presented of the maximum values and time behavior of the thermohydraulic parameters, pressure, temperature, relative humidity, and water level on the floor. Transverse rupture of the steam generator, main steam header, or main feedwater header piping during normal operation is considered as the initiating event. Pressure is only 10% higher than the atmospheric pressure. Air temperature attains a value as high as 100 degC. Relative humidity is 100%, persisting as long as the steam source is available. The water level is typically about 8 cm and never exceeds 15 cm. (M.D.). 16 tabs., 37 figs., 32 refs.

259

Radiological considerations of the reactor cover gas processing system at the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).

1986-09-24

260

Learning and case-based reasoning for faults diagnosis-aiding in nuclear power plants  

International Nuclear Information System (INIS)

The aim of this thesis is the design of a faults diagnosis-aiding system in a nuclear facility of the Cea. Actually the existing system allows the optimization of the production processes in regular operating conditions. Meanwhile during accidental events, the alarms, managed by threshold, are bringing no relevant information. To increase the reliability and the safety, the human operator needs a faults diagnosis-aiding system. The developed system, SECAPI, combines problem solving techniques and automatic learning techniques, that allow the diagnosis and the the simulation of various faults happening on nuclear facilities. Its reasoning principle uses case-based and rules-based techniques. SECAPI owns a learning module which reads out knowledge connected with faults. It can then simulate various faults, using the inductive logical computing. SECAPI has been ...

1998-01-01

263

Performance of a commercial heat pipe under operational conditions  

Energy Technology Data Exchange (ETDEWEB)

The performance of a commercial heat pipe was investigated both experimentally and theoretically. The effect of the temperature difference, the surface area ratio, and the operational conditions on the performance were studied. The heat flow rate and the vapor temperature were estimated on a ready-made commercial heat pipe. Its performance varied considerably with operational conditions. Theoretical consideration of a mathematical model and several nomographs are also presented. This work is applicable to the design and use of heat pipes in the field.

1983-04-01

265

Experimental studies of 6-inch pipe whip tests under BWR LOCA conditions  

International Nuclear Information System (INIS)

Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The ...

268

Cheng cycle cogeneration system; Cheng cycle system cogeneration setsubi  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the Cheng cycle system featured by variable heating/generation ratio for effective operation of cogeneration systems (CGS). In this system, a superheater and reheating burner are added to an exhaust heat recovery (EHR) boiler for conventional gas turbine CGSs, while additional injection steam piping is attached to a gas turbine. Steam is injected through manifolds mounted on the periphery of a combustion chamber, and hot gas mixture of steam and air in a combustion chamber is expanded in a turbine and converted to motive power. This technology thus can improve efficiency and output power, and can operate variably CGSs corresponding to heating and generation demands. This technology has been promoted by introducing the technology of middle class Cheng cycle CGS with 4MW class gas turbine from IPT Co., U.S.A. The first system of 6400 kW is now under production for ...

1996-03-29

269

The mixed waste management facility: Cost-benefit for the Mixed Waste Management Facility at Lawrence Livermore National Laboratory  

International Nuclear Information System (INIS)

The Mixed Waste Management Facility, or MWMF, has been proposed as a national testbed facility for the demonstration and evaluation of technologies that are alternatives to incineration for the treatment of mixed low-level waste. The facility design will enable evaluation of technologies at pilot scale, including all aspects of the processes, from receiving and feed preparation to the preparation of final forms for disposal. The MWMF will reduce the risk of deploying such technologies by addressing the following: (1) Engineering development and scale-up. (2) Process integration and activation of the treatment systems. (3) Permitting and stakeholder issues. In light of the severe financial constraints imposed on the DOE and federal programs, DOE/HQ requested a study to assess the cost benefit for the MWMF given other potential alternatives to meet waste treatment needs. The MVVMF Project was asked to ...

2005-10-01

270

A combined cycle engine test facility  

Energy Technology Data Exchange (ETDEWEB)

Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in which the propulsive force was generated by rocket only, the ramjet only and ...

1995-09-01

271

Experimental and analytical studies of pipe whip tests under PWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

A series of pipe rupture tests has been performed at JAERI to demonstrate the safety of primary coolant circuits in the event of pipe rupture in nuclear power plants. Pipe whip tests and jet discharge tests have been conducted under BWR and PWR loss-of-coolant accident (LOCA) conditions. The present paper describes the experimental and analytical results of the pipe whip tests performed under PWR LOCA conditions using 4, 6 and 8-inch test pipes. The tests were carried out at an initial pressure and temperature of 15.7 MPa and 325/sup 0/C, respectively. Moreover, a dynamic analysis of pipe whip tests was carried out using the general purpose finite element programm ADINA.

1987-09-01

272

The upgrade of nuclear material accounting system at KAERI  

International Nuclear Information System (INIS)

The agreement between the government of Republic Of Korea (ROK) and the IAEA for the application of safeguards was signed and entered into force in 1975. The Additional Protocol (AP) to the Safeguards Agreement between the ROK and the IAEA was signed in 1999 and entered into force on 19 February 2004. Also, Implementation of Integrated Safeguards (IS) was started on 1 July, 2008 after a draw of the broader conclusion. The IAEA provides 2 hours notification for Random Interim Inspection (RII) under IS. For RII, the facility has to prepare the inspection documents in a short time. Therefore, KAERI (Korea Atomic Energy Research Institute) developed a new computerized nuclear material accounting system named KASIS (KAERI Safeguards Information treatment System) to treat the data by on-line for RII. For the efficient IS implementation, KAERI has a plan to upgrade the system to reflect the accounting ...

2010-10-01

273

Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, ...

2004-06-16

274

Comparative study of computational model for pipe whip analysis  

International Nuclear Information System (INIS)

Many types of pipe whip restraints are installed to protect the structural components from the anticipated pipe whip phenomena of high energy lines in nuclear power plants. It is necessary to investigate these phenomena accurately in order to evaluate the acceptability of the pipe whip restraint design. Various research programs have been conducted in many countries to develop analytical methods and to verify the validity of the methods. In this study, various calculational models in ANSYS code and in ADLPIPE code, the general purpose finite element computer programs, were used to simulate the postulated pipe whips to obtain impact loads and the calculated results were compared with the specific experimental results from the sample pipe whip test for the U-shaped pipe whip restraints. Some calculational models, having the spring element between the ...

1993-08-15

275

On the development of the METAR family of inspection tools  

Energy Technology Data Exchange (ETDEWEB)

Since 1998, Hydro Quebec Research Centre (IREQ), in collaboration with Gentilly-2, has been working on the development of inspection devices for the feeder tubes of CANDU power plants. The first tool to come out of this work was the Metar bracelet, now used throughout the CANDU utilities, consisting of 14 ultrasonic probes held in place in a rigid bracelet to measure the thickness of the pipes and moved around manually along the pipe. Following the success of the Metar, a motorized version, i.e. the Crawler, has been developed to inspect beyond the operator arm's reach to access hard to reach place or further down the pipes in the reactor. This new system has been tested at 3 different stations and will be commercially available soon. Finally, the same technology was used to develop a motorized 2-axis crack detection device to answer new concerns about the feeder. Other configurations, ...

2003-07-01

276

Lauric and palmitic acids eutectic mixture as latent heat storage material for low temperature heating applications  

Energy Technology Data Exchange (ETDEWEB)

Palmitic acid (PA, 59.8 {sup o}C) and lauric acid (LA, 42.6 {sup o}C) are phase change materials (PCM) having quite high melting temperatures which can limit their use in low temperature solar applications such as solar space heating and greenhouse heating. However, their melting temperatures can be tailored to appropriate value by preparing a eutectic mixture of the lauric and the palmitic acids. In the present study, the thermal analysis based on differential scanning calorimetry (DSC) technique shows that the mixture of 69.0 wt% LA and 31 wt% PA forms a eutectic mixture having melting temperature of 35.2 {sup o}C and the latent heat of fusion of 166.3 J g{sup -1}. This study also considers the experimental determination of the thermal characteristics of the eutectic mixture during the heat charging and discharging processes. Radial and axial temperature distribution, heat transfer coefficient between the heat transfer fluid (HTF) pipe and the PCM, heat recovery ...

2005-04-01

277

Dalia integrated production bundle (IPB): an innovative riser solution for deep water fields  

Energy Technology Data Exchange (ETDEWEB)

The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 deg C on arrival at the FPSO, this problem ...

2008-07-01

278

Study of the state of design for pipe whip. Final report. [PWR; BWR  

Energy Technology Data Exchange (ETDEWEB)

Design methods and parameters are described which are addressed when considering consequences of a postulated pipe rupture event in a nuclear plant design. Parameters discussed are break opening time and size, resultant blowdown characteristics of the effluent from the broken pipe, jet reaction and impingement loading, pipe motion, and pipe impact loading on steel and concrete structures. The impact the various parameters have on overall plant designs and conservatisms inherent in each consideration are evaluated in a qualitative nature. Finally, recommendations are provided for each parameter discussed for further evaluation and study.

1980-01-01

279

Research on pipe whip and jet under LOCA conditions, (2)  

International Nuclear Information System (INIS)

The paper describes the experimental and analytical results of the pipe whip tests performed under the PWR LOCA conditions using 4, 6 and 8 inch test pipes. The tests were carried out at an initial pressure and a temperature of 15.7 MPa and 325 "0C. Two different types of tests were performed. One was the cantilever type pipe whip test using the test pipe of 3000 mm in length and U-shaped restraints. The other was the cross-over leg pipe whip test using a 1/6 model of piping in the PWR nuclear power plants. The cantilever type pipe whip tests were performed to investigate the influences of overhang length and pipe diameter on the pipe whip behavior. The movement of the test pipe is limited effectively by the restraints when the overhang length is short. The restraint force ...

280

Heat pipe cooled piston - feasibility study  

Energy Technology Data Exchange (ETDEWEB)

This study assesses the feasibility of the so-called heat pipe technique for cooling the piston of a mediumspeed diesel engine and is part of a research project 'EVE HPD, Extreme Value Engine Tests with High Power Density' carried out by HUT Internal Combustion Engine Laboratory. Diesel engines are being developed to give greater power from a given cylinder swept volume, which means higher temperatures in combustion chamber. The traditional oil cooling cannot be used beyond certain temperature level. Heat pipe technology could provide one solution to the cooling problem. The general properties, principles of operation, and structures of different types of heat pipes are described. Working fluids and container materials of heat pipes are discussed. The operation limitations of heat pipes are studied, especially, the limitations of a reciprocating heat ...

2004-07-01

281

Tools and methods for implementing the control systems on the Mirror Fusion Test Facility  

Energy Technology Data Exchange (ETDEWEB)

Installation of the major hardware subsystems for MFTF is nearing completion. These subsystems include the Fusion Chamber System, the eighty KV Neutral Beam System, the Superconducting Magnet System, and the Personnel Safety System. The Local Controls group has undertaken a uniform aproach to implementing the control systems for all of these hardware subsystems. This approach has two major aspects: (1) to provide a stand-alone computer control system with a remote, portable terminal so that computer control can be provided at the site of the hardware for initial testing, (2) to provide hardware simulators so that the complicated MFTF computer control system can be tested independent of the hardware. The software and hardware tools which were developed to carry out this plan will be described. Our experiences with bringing up subsystems ...

1981-09-29

282

Thermohydraulic study of a MTR fuel element aimed at the construction of an irradiation facility; Estudo termohidraulico de um elemento combustivel tipo MTR visando a construcao de um dispositivo de irradiacao  

Energy Technology Data Exchange (ETDEWEB)

A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)

1980-07-01

283

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

284

Coal-liquefaction-process research quarterly report, January 1 - March 31, 1982  

Science.gov (United States)

Objectives of the program are to understand the mechanisms of coal liquefaction, to determine the role of catalysts in the direct conversion of coal to liquids, to determine the mechanism of catalyst deactivation and to explore slurry phase catalyst systems. Specific projects include: short-contact time coal liquefaction, mineral matter effects and catalyst studies. During this period, work was performed on: (1) the stability, at reaction temperature, of a recycle solvent obtained from the Lummus Two Stage Liquefaction facility, (2) reactions of preasphaltenes and asphaltenes prepared under various reaction severities, (3) the evaluation of the catalyst level detector installed at the H-Coal facility, (4) the characterization of oil soluble metal compounds with respect to hydrogenation activity, and (5) characterization, deactivation and regeneration of catalysts obtained from both the H-Coal and Lummus ...

1982-10-01

285

1 The German National Analysis Facility as a tool for ATLAS analyses  

CERN Document Server

In 2008 the German National Analysis Facility (NAF) at DESY was established. It is attached to and builds on top of DESY Grid infrastructure. The facility is designed to provide the best possible analysis infrastructure for high energy particle physics of the ATLAS, CMS, LHCb and ILC experiments. The Grid and local infrastructure of the NAF is reviewed with a focus on the ATLAS part. Both parts include large scale storage and a batch system. Emphasis is put on ATLAS specific customisation and utilisation of the NAF. This refers not only to the NAF components but also to the di erent components of the ATLAS analysis framework. Experience from operating and supporting ATLAS users on the NAF is presented in this paper. The ATLAS usage of the di erent components are shown including some typical use cases of user analysis. Finally, the question is addressed, if the design of the NAF meets the ATLAS expectations for effcient data ...

2011-01-01

286

DYMAC communications system  

Energy Technology Data Exchange (ETDEWEB)

The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system ...

1980-01-01

287

The Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama  

Energy Technology Data Exchange (ETDEWEB)

This report presents the operating results for Run 255 at the Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. This run operated in the Close Coupled Integrated Two-Stage Liquefaction mode (CC-ITSL) using Martin Lake Texas lignite. The purpose of this run was to demonstrate unit and system operability with Martin Lake lignite. Run 255 began on 20 March 1988 and continued through 9 June 1988. During this period, 204.4 MF tons of Martin Lake Texas lignite were fed in 1865.5 hours of operation. 70 figs., 21 tabs.

1991-05-01

288

Testing of the 1-MWth bench-model cavity-receiver steam generator  

Science.gov (United States)

A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)

289

How Waste Management Can Be Influenced By Transport Packagings  

Science.gov (United States)

With major D&D projects ongoing or being planned, and also with the daily management of radwaste from nuclear facilities, the potential role of transport packagings has often been overlooked: here will one rely essentially on drums, there several local waste processing units are built, elsewhere decommissioned facilities are cut in small bits to fit into small containers by far less efficient. The present paper proposes to illustrate how integrating a transport system from the start may influence operational choices of waste management.

2002-02-28

290

Bechtel Hanford Inc. Network Security Plan for the EnvironmentalRestoration Contract  

Science.gov (United States)

'As part of the Computer Protection Plan, this Network Security Plan identifies the specific security measures used to protect Bechtel Hanford, Inc.'s (BHI's) enterprise network. The network consists of the communication infrastructure and information systems used by BHI to perform work related to the Environmental Restoration Contract (ERC) at the Hanford Site. It provides electronic communication between the ERC-leased facilities in Richland, Washington, and facilities located on the Hanford Site. Network gateways to other site and offsite networks provide electronic communication with the remainder of the Hanford community.'

1999-06-30

291

Reflux boiling heat removal in a scaled TMI-2 system test facility  

International Nuclear Information System (INIS)

An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.

1980-06-01

292

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

293

Odor purification by bio-function; Seibutsu kino niyoru akushujoka  

Energy Technology Data Exchange (ETDEWEB)

Odor purification process using bio-function, which is technologically called bio-deodorizing process, utilizes the function of microorganism to convert mal-odor substances to non-odor substances. It attracts attention because the operation cost of a facility is low due to non-use of chemicals and energy, and because it is environmentally friendly without the possibility of generating secondary pollution. It is being used in deodorizing at sewage treatment facilities, fertilizer plants, coating plants, and foundries in Japan, and is more widely used in Europe. The conventional deodorizing technology in Japan mostly focuses on processes of physical chemistry such as activated carbon treatment, chemical scrubbing, combustion, and masking, but bio-deodorizing process tends to replace the conventional processes. This paper explains (1) relation of mal-odor and microorganism, (2) bio-deodorizing system (solid phase ...

1999-11-30

294

Increased capability of Strassy: the decision making aid for the inspection of nuclear materials; Prolongement des capacites de Strassy: systeme d`aide a la decision pour le controle des matieres nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The paper describes the latest developments in STRASSY (Strategy Assistance System), the strategy assistance system for the inspection of nuclear materials. The user can now select the fuel cycle he wishes to investigate from an initial range of 19 facilities. An inspection interface has been developed to enable the details and dates of inspections to be modified. One of the special features of the application of STRASSY in international safeguards is the taking into account of timeliness of detection; certain aspects of the time manager algorithms are presented and analysed, including the guaranteed existence of a solution. The results of a study of diversion paths in a simplified cycle consisting of our facilities are presented. Finally, the modifications necessary to enable STRASSY to be used for a posterior analysis of inspection results are discussed. (authors). 7 refs., 3 figs.

1994-12-31

295

Five years operating experience at the Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...

1987-04-01

296

Five years operating experience at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...

1987-09-13

297

Fabrication of core demonstration experiments for irradiation in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

A major initiative to develop and irradiate a long-life, mixed-oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the US Department of Energy. The FFTF, shown in Figures 1 and 2, is a 400 megawatt thermal, fast liquid metal reactor that tests liquid metal, space and fusion fuels and materials. The new fuel system, called the Core Demonstration Experiment (CDE) demonstrates the capability of achieving a three- to four-year life in a prototypic heterogeneous reactor environment under prototypic power and temperature conditions. This fuel system will greatly increase fuel performance and lifetime from the current standard FFTF driver fuel. New design features, fabrication development, CDE assembly fabrication, and irradiation status have been described.

1990-06-10

298

FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation  

International Nuclear Information System (INIS)

The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.

299

FFTF (Fast Flux Test Facility) reactor shutdown system reliability reevaluation  

Energy Technology Data Exchange (ETDEWEB)

The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.

1986-07-01

300

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

301

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

302

Nuclear fuel assembly identification using computer vision  

Science.gov (United States)

This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.

1985-11-01

303

Long-term preventive maintenance of instrumentation control equipment for PWR plants  

International Nuclear Information System (INIS)

Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)

2006-02-01

304

Hydraulic braking system for loads subjected to impacts and vibrations  

International Nuclear Information System (INIS)

This invention concerns a hydraulic braking system for loads subjected to impacts and vibrations. These double acting telescopic type hydraulic braking systems possess significant drawbacks linked to possibly important hydraulic leaks due to (a) the use of many dynamic seals in such appliances and (b) the effects of the environment of the system on these seals, particularly when employed in nuclear power stations where the seals reach significant temperatures and are subjected to radiation. Under this invention a remedy is suggested to such drawbacks by integrating means to offset automatically the leaks and the accumulation of hydraulic fluid expansions, as well as facilities to show if such leaks have occurred.

305

Distributed-processing radiation management system for nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)

1999-06-01

306

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

307

The LLNL computer control system  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.

1991-10-03

308

Radisson community heating systems: technical and economic comparison of options. Final report  

Energy Technology Data Exchange (ETDEWEB)

The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.

1981-12-01

309

Overview of IAEA year 2000 activities in the Department of Safeguards  

International Nuclear Information System (INIS)

The IAEA Department of Safeguards established a project in 1996 for the year 2000 (Y2K) conversion activities. This project covered assessment, conversion and testing of the software applications, instrument evaluation software, embedded systems and Personal Computer (PC) hardware attached to various equipment. Significant progress has been made in converting the applications and instruments to be year 2000 compliant. At the same time Member states have made an effort as well in converting the systems used jointly at the facilities

1999-02-01

310

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

311

Corrosion of Cu-W condensates in tap water  

International Nuclear Information System (INIS)

Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.

312

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This ...

2009-07-01

313

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility ...

2009-06-07

314

Long-term storage facility for reactor compartments in Sayda Bay - German support for utilization of nuclear submarines in Russia  

Science.gov (United States)

The German-Russian project that is part of the G8 initiative on Global Partnership Against the Spread of Weapons and Materials of Mass Destruction focuses on the speedy construction of a land-based interim storage facility for nuclear submarine reactor compartments at Sayda Bay near Murmansk. This project includes the required infrastructure facilities for long-term storage of about 150 reactor compartments for a period of about 70 years. The interim storage facility is a precondition for effective activities of decommissioning and dismantlement of almost all nuclear-powered submarines of the Russian Northern Fleet. The project also includes the establishment of a computer-assisted waste monitoring system. In addition, the project involves clearing Sayda Bay of other shipwrecks of the Russian navy. On the German side the project is carried out by the Energiewerke Nord GmbH (EWN) on behalf of the Federal ...

2007-07-01

315

The effects of gaseous environments on the mechanical failure of polyethylene pipe materials. Annual technical report 1 Nov 80-31 Oct 81  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene gas piping is expected to be in service for times on the order of 50 years depending on service conditions. Therefore research research on piping materials and pipes has two principal objectives: (a) developing methods for predicting when a pipe will fail and (b) improving the material for piping. The prediction of long time failure hinges on the development of short time test methods which relate to long time failure. The improvement in the behavior of current materials also hinges on the use of test methods of short duration relative to the anticipated life time of the pipe in service. One of the primary criterion for an acceptable test method is that it produces the same type of failure as is observed after long time failure in service. It has been found that P.E. pipe material fails in a brittle mode after long periods of ...

1981-10-01

316

Pipe-to-pipe impact program  

Energy Technology Data Exchange (ETDEWEB)

The objective of this research was to determine the extent of damage that occurs when two pipes experience an impact event due to one whipping against the other. The research was conducted through experimental and analytical approaches. The former required the development of a specialized impact machine that could accelerate a whipping pipe with sufficient energy to cause failure of a target pipe that was heated and pressurized to Pressurized Water Reactor (PWR) conditions. Damage was measured in terms of crushing, bending, and failure. The results of the tests permitted the correlation between pipes of a certain size and the damage they could cause when impacting with a certain amount of known energy. These results were used to evaluate the pipe whip criteria in the Standard Review Plan 3.6.2-4. It was established that the criteria conditions did not fully represent the results ...

1987-05-01

317

Power Systems Development Facility Gasification Test Campaign TC17  

Energy Technology Data Exchange (ETDEWEB)

In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR (formerly Kellogg Brown & Root) Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results gasification operation with Illinois Basin bituminous coal in PSDF test campaign TC17. The test campaign was completed from October 25, 2004, to November 18, 2004. System startup and initial operation was accomplished with Powder River Basin (PRB) subbituminous coal, ...

2004-11-30

318

Quantitative model of vapor dominated geothermal reservoirs as heat pipes in fractured porous rock  

Science.gov (United States)

We present a numerical model of vapor-dominated reservoirs which is based on the well-known conceptual model of White, Muffler, and Truesdell. Computer simulations show that upon heat recharge at the base, a single phase liquid-dominated geothermal reservoir in fractured rock with low matrix permeability will evolve into a two-phase reservoir with B.P.D. (boiling point-for-depth) pressure and temperature profiles. A rather limited discharge event through cracks in the caprock, involving loss of only a few percent of fluids in place, is sufficient to set the system off to evolve a vapor-dominated state. The attributes of this state are discussed, and some features requiring further clarification are identified. 26 refs., 5 figs.

1985-03-01

319

Interfacial area transport: data and models  

International Nuclear Information System (INIS)

The objective of this research is to replace the current flow regime dependent interfacial area correlations in the thermal-hydraulic system analysis codes with an interfacial area transport equation, which dynamically models two-phase flow regime transitions. The interfacial area transport equation applicable to bubbly flows has been developed based on mechanistic modeling of bubble interaction. Detailed experiments have been performed for bubbly conditions in 2.54, 5.08 and 10.16-cm ID pipes to benchmark the model. This new approach predicts the continuous changes of the interfacial area and will eliminate artificial bifurcations stemming from the use of the static flow regime transition criteria. This paper presents the preliminary results of incorporating the one-group transport equation into the USNRC consolidated code, currently under development. The framework for the two-group transport equation and the necessary constitutive relations ...

2001-05-23

320

Interfacial area transport equation: model development and benchmark experiments  

Energy Technology Data Exchange (ETDEWEB)

The interfacial area transport equation dynamically models two-phase flow regime transitions and predicts continuous changes of the interfacial area concentration along the flow field. It replaces the flow regime-dependent correlations for the interfacial area concentration in thermal-hydraulic system analysis. In the present study, detailed formulation of the interfacial area transport equation is presented along with its evaluation results based on the detailed benchmark experiments. In view of model evaluation, the equation is simplified into one-dimensional steady state one-group interfacial area transport equation. The prediction made by model agrees well with the experimental data obtained in round pipes of various diameters. The framework for the two-group transport equation and the necessary constitutive relations are also presented in view of bubble transport of various sizes and shapes. (author)

2002-07-01

321

Fracture mechanics: proceedings of the 12th national symposium on fracture mechanics  

Energy Technology Data Exchange (ETDEWEB)

The conference proceedings contains 30 papers of which five are abstracted separately. The subjects covered include fatigue crack growth in aircraft materials, fractographic measurements, fatigue cracks in nylon 66 blends, cyclic inelastic deformation aspects, prestressing, tensile cracks in creeping solids, creep-crack-growth in 304 stainless steel, high-temperature fatigue, parallel impact loading, numerical fracture dynamic code, J-resistance curves, specimen geometry effects, reactor piping systems, temperature dependence of fracture toughness, small-scale yielding, compact specimens, power hardening materials, semi-empirical fracture analyses, pipeline girth welds, wrought steels, and A36 bridge steels.

1980-01-01

322

Emergency core cooling system  

International Nuclear Information System (INIS)

Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an electrically actuated valve controlled by a control device. (Furukawa, ...

323

Dismantling by explosives  

Energy Technology Data Exchange (ETDEWEB)

Explosives have rarely been used in decommissioning of nuclear reactors. Nevertheless, controlled blasting can be used advantageously during careful destruction of nuclear power plants for removal of concrete, pipe systems, and other components. Experiments performed within a former nuclear power plant demonstrate the feasibility of this method, employing explosive masses up to 15 kg per blast. The loadings of the components and the total plant structure were measured and compared with code predictions. The experiments show a response of the containment predominantly in frequency ranges above 100 Hz, thus keeping the building and components below German regulation limits for shock excitation. The blast wave pressures are reduced drastically within short distances in the building. Dust and debris can be contained with simple methods such as curtains. Use of this method seems to be applicable to actual dismantling projects.

1989-08-01

324

Development of Seismic Analysis Model and Time History Analysis for KALIMER-600  

Energy Technology Data Exchange (ETDEWEB)

This report describes a simple seismic analysis model of the KALIMER-600 sodium cooled fast reactor and its application to the seismic time history analysis. To develop the simple seismic analysis model, the detailed 3-D finite element analyses for main components, IHTS piping system, and reactor building were carried out to verify the dynamic characteristics of each part of simple seismic analysis models. By using the developed simple model, the seismic time history analyses for both cases of a seismic isolation and non-isolation design of KALIMER-600 were performed. From the comparison of the calculated floor response spectrum, it is verified that the seismically isolated KALIMER-600 reactor building shows a great performance of a seismic isolation and assures a seismic integrity.

2007-02-15

325

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

326

Averting problems caused by solutions  

International Nuclear Information System (INIS)

A brief overview is given of a report on Emergency Core Cooling Systems (ECCS) Recirculation Reliability Knowledge Base compiled by the International Working Group on ECCS Reliability for the OECD/NEA/CSNI. Four safety issues are identified which arise in the context of loss of coolant accidents (LOCAs) and are connected with materials and/or processes that interfere with the ECCS safety function in ways other than just strainer head loss generation. They are: the generation of missiles during a LOCA from encapsulated insulation materials used to reduce insulation debris production; clogging of BWR pressure suppression containment vent pipes by insulation jackets or metallic insulation foil pieces; strainer or sump debris ingestion and the effects of ingested debris on ECCS equipment and core cooling; miscellaneous items such as material aging and self-cleaning strainer concepts. The emphasis is mainly on BWRs but many of the considerations ...

327

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. ...

1999-07-01

328

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. ...

1999-04-19

329

Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in the Be-coating at the midplane of the outboard first wall is ...

1994-07-01

330

Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants  

International Nuclear Information System (INIS)

This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. The methodology is based on ...

1992-07-01

331

Closure Report for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada  

Energy Technology Data Exchange (ETDEWEB)

This Closure Report (CR) documents closure activities for Corrective Action Unit (CAU) 543, Liquid Disposal Units, according to the Federal Facility Agreement and Consent Order (FFACO, 1996) and the Corrective Action Plan (CAP) for CAU 543 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2007). CAU 543 is located at the Nevada Test Site (NTS), Nevada (Figure 1), and consists of the following seven Corrective Action Sites (CASs): CAS 06-07-01, Decon Pad; CAS 15-01-03, Aboveground Storage Tank; CAS 15-04-01, Septic Tank; CAS 15-05-01, Leachfield; CAS 15-08-01, Liquid Manure Tank; CAS 15-23-01, Underground Radioactive Material Area; CAS 15-23-03, Contaminated Sump, Piping; and CAS 06-07-01 is located at the Decontamination Facility in Area 6, adjacent to Yucca Lake. The remaining CASs are located at the former U.S. Environmental Protection Agency (EPA) Farm in Area 15. The ...

2008-01-01

332

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, ...

2002-02-01

333

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

334

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

1981-08-06

335

Apparatus for total hemispherical emittance measurements of full-scale receiver pipes from 100 to 300 C  

Energy Technology Data Exchange (ETDEWEB)

An apparatus is described for measuring the total hemispherical emittance of pipes of a length suitable for use in a prototype solar collector. The calorimetric method used requires measurements of the temperatures of the surface of the test pipe and of a concentric outer cylinder and measurement of the electrical power used to heat the test pipe. Measurements were made of the total hemispherical emittance of black chrome, nickel, and bare steel pipes as a function of temperature. The emittance of the black chrome surfaces increased significantly from an extrapolated value of about 0.1 at 25 deg C to values on the order of 0.3-0.4 at 300 deg C. The extrapolated values for black chrome agreed with measurements made using other techniques at room temperature. The results for the nickel-plated pipe agreed with total emittance calculated from spectral reflectance data.

1981-01-01

336

A smart location system  

Energy Technology Data Exchange (ETDEWEB)

Details of a novel intelligent pipeline anomaly location system were presented. The system was based on the emission and reception of extra low frequencies(ELF) disposed close to a pipeline that were then logged in the memory of an in-line inspection (ILI) tool to provide a more precise reference than time-based above-ground marker systems for the location of pipeline anomalies. The system consisted of 2 pairs of transmitter (TX) and receiving (RX) circuits working at low and varied frequencies. An additional module was installed in the front section of an ILI tool, which contained a frequency transmitter whose signals are transmitted through cabling to an external transmitter and retransmitted simultaneously to a receiver installed in the rear section of an additional module of the tool in order to guarantee that the signal recorded by the tool corresponded to the smart location ...

2004-07-01

337

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support area are congested. And also, workers involved in inspecting feederpipe support area ...

2000-07-01

338

Theory and evidence of economies of scale in the development of waste management systems  

Energy Technology Data Exchange (ETDEWEB)

Waste is a cost of doing business. This cost can be considered in terms of the potential adverse health and environmental impacts, or the waste management costs associated with avoiding, minimizing, and controlling those impacts. There is an anticipated increase in the cost of waste management as a result of the increasing requirements for regulatory compliance. To meet the total waste management capacity needs of the organization and the compliance requirements, low-level radioactive, hazardous, and mixed waste management will need demonstrated technologies strategically managed as a technology portfolio. The role of the decision maker is to select the optimum mix of technologies and facilities to provide the waste management capacity needed for the next twenty years. The waste management system resulting from this mix includes multiple small-scale fixed facilities, large-scale centralized facilities, ...

1989-01-01

339

Construction of the DIVA(direct vessel injection visualization and analysis test facility) for the LBLOCA of KNGR  

Energy Technology Data Exchange (ETDEWEB)

In this report, the descriptions of the DIVA test facility and those test matrixes are presented. The test sections simulate the downcomer annulus of DVI system with various scalling methodologies. The UPTF one has 1/7.5 scale and the APR-1400 test sections are reduced in 1/7 scale and 1/5 scale respectively. Also, the instrumentations, measuring methods are described. The major measuring parameters are ECC injection rate, air injection rate, bypass fraction, system pressure and so on. And finally, the operation procedure and experimental steps are introduced. From the DIVA tests, the multi-dimensional behaviors of two-phase flow in the downcomer during the reflood phase can be investigated using a transparent test facility. Also comparing the experimental data which are performed in various scale downcomer, it is expected that some criteria of scalling methodology proper to the DVI ...

2002-03-01

340

University of Central Lancashire - Facilities  

Wastenet

...specialised laboratories for pharmaceutics, tissue culture and molecular biology Excellent Laboratory Facilities Tissue Culture Facilities Molecular Biology Laboratory ...

341

Advanced Neutron Source: Plant Design Requirements. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) ...

1990-07-01

342

MTF analysis of the MURR real-time neutron radiography facility  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor ...

1982-04-01

343

Development of the high-tension distribution line design support system; Koatsu gaisen sekkei shien system no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

The 'high-tension distribution line design support system' was developed for the 'work design support system'. This support system is composed of the work outline editor for preparing work details and facility data and the inference engine for preparing practical design plans, and can check system conditions such as voltage drop and deviation from technical standards automatically. The work outline editor takes charge of selection of work items, selective input of system information, and setting of some conditions such as pole position and reserved load onto a system diagram. The inference engine provides the design plan automatically based on the information inputted by the editor. For the design of high-tension distribution line, such various factors as local condition and load sharing of distribution ...

2000-02-10

344

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type ...

1995-07-01

345

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel ...

1346-01-01

346

Overview of Cooling Water System for the KSTAR 1st Plasma Experiment  

International Nuclear Information System (INIS)

The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008

2009-05-01

347

Naval Sea Systems Command occupational safety and health record-keeping system. Hazardous Materials Control Module. Program maintenance manual  

Energy Technology Data Exchange (ETDEWEB)

Since August 1984, the MITRE Corporation has been supporting the Naval Sea Systems Command (NAVSEA) and the Naval Medical Command (NAVMEDCOM) in their joint efforts to enhance the Navy Occupational Health Information Management System (NOHIMS). The goal of the enhancement effort was to create a comprehensive occupational health and safety system for Navy industrial facilities by expanding upon the original NOHIMS functions and adding modules for hazard deficiency abatement, hazardous-material control, injury claims and compensation, and safety and health training. To meet this goal, MITRE developed an enhanced industrial subsystem, referred to as the Occupational Safety and Health Record Keeping System (OSHRKS), using a prototyping approach and a public-domain data base-management software package, the Veterans Administration's (VA's) FileManager (FileMan).

1987-06-01

348

UK Achievements in the application of power fluidic technology for nuclear processing plants  

International Nuclear Information System (INIS)

Power Fluidic systems for the control of liquids and gaseous flows have been adopted for use in radioactive processing plants in the UK. These devices are intrinsically reliable with no mechanical moving parts because they are able to make use of the hydrodynamics of the fluids being controlled. This reliability feature leads to a zero cell maintenance concept and the elimination of mechanical drive/control systems in cell. The first phase of the development work led to their use in the Fast Reactor Reprocessing Plant at Dounreay and the Highly Active Liquor Storage facility at Sellafield. The success of these early developments has led to an extensive development programme for an extended range of applications in the Thermal Oxide Reprocessing Plant and its associated waste treatment facilities at Sellafield. The technology has now been fully demonstrated and adopted for these plants with considerable ...

349

Status of FFTF startup program and future FFTF utilization  

International Nuclear Information System (INIS)

A brief FFTF project description is provided which includes general plant siting information, general layout, plant design parameters, description of principal systems and components, and description of support facilities. The current status of the FFTF project is provided, including status of plant construction, overall status of the plant checkout and test program, status of operating authorization and plant operating procedures and personnel, and status of reactor core components and experiments. Specific information on the acceptance test program and early program results is discussed. The role of FFTF in the future breeder program is described, including its objectives for verification of plant system and components designs and operability and use as an irradiation test facility.

1978-10-25

350

Simulation of the New York Power Pool for dispatcher training  

Science.gov (United States)

This paper describes the simulation of the operating environment of the New York Power Pool (NYPP) within the Dispatcher Training Simulator facility at the New York State Electric and Gas Corporation (NYSEG). The NYSEG control center uses real-time data received from the NYPP control center to control its internal generation. In addition, the NYSEG dispatchers work very closely with the NYPP dispatchers. The exact emulation of the Generation Control functions of the NYPP EMS, and the associated data exchange with the NYSEG ECS, contribute greatly to the high degree of realism achieved in the NYSEG DTS facility. The accuracy of the power system simulation in the DTS has been validated against actual power system disturbances recorded at NYSEG.

1994-11-01

351

Reactor cover gas monitoring at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-megawatt (thermal) sodium-cooled reactor designed for irradiation testing of fuels, materials and components for LMRs. It is operated by the Westinghouse Hanford Company for the US Department of Energy on the government-owned Hanford reservation near Richland, Washington. The first 100-day operating cycle began in April 1982 and the eighth operating cycle was completed in July 1986. Argon is used as the cover gas for all sodium systems at the plant. A program for cover gas monitoring has been in effect since the start of sodium fill in 1978. The argon is supplied to the FFTF by a liquid argon Dewar System and used without further purification.

1986-09-24

352

High-level waste canister storage final design, installation, and testing. Topical report  

Energy Technology Data Exchange (ETDEWEB)

This report is a description of the West Valley Demonstration Project`s radioactive waste storage facility, the Chemical Process Cell (CPC). This facility is currently being used to temporarily store vitrified waste in stainless steel canisters. These canisters are stacked two-high in a seismically designed rack system within the cell. Approximately 300 canisters will be produced during the Project`s vitrification campaign which began in June 1996. Following the completion of waste vitrification and solidification, these canisters will be transferred via rail or truck to a federal repository (when available) for permanent storage. All operations in the CPC are conducted remotely using various handling systems and equipment. Areas adjacent to or surrounding the cell provide capabilities for viewing, ventilation, and equipment/component access.

1998-04-01

353

Fabrication of core demonstration experiments for irradiation in the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

A major new initiative to develop and irradiate a long-lived, mixed-oxide (MOX) fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the U.S. Department of Energy. The purpose of this new fuel system, called the core demonstration experiment (CDE), is to demonstrate the capability of achieving a 3-yr life in a prototypical, heterogeneous reactor environment under prototypical power and temperature conditions. Ten fuel and six blanket CDEs are establishing the performance characteristics of entire fuel assemblies of wire-wrapped, large-diameter, annular-pellet, advanced MOX fuel pins with the tempered martensitic HT-9 alloy cladding and end caps, HT-9 wire wrap, and an HT-9 duct in a heterogeneous array with the blanket assemblies. The CDE performance characteristics are confirming the basis for design, fabrication, and irradiation of the CDE.

1990-06-10

354

Energy management, real estate management, and facility management; Energiemanagement in der Immobilienverwaltung  

Energy Technology Data Exchange (ETDEWEB)

The publication presents an outline of the subject of energy management and attempts to test the hypotheses that targeted knowledge management may result in new developments and potentials, and if these are at all desirable. On this basis, a knowledge management system will be developed that may effectively promote developments and potentials in the field of energy management. The tools and fundamentals of energy management are looked into, and the given situation and desired goals are identified by means of an enquiry. This is a scientific study that aims at providing empirical information on the situation and views on the subject of energy management. The analysis, which is supported by an enquiry sheet, is to provide a basis for testing the assumed hypothesis. Further, the potential acceptance and utilization potential of decisive knowledge management in the facility and real estate management sector are to be tested. The energy knowledge ...

2010-07-01

355

Characterization of Filter Elements for Service in a Coal Gasification Environment  

Energy Technology Data Exchange (ETDEWEB)

The Power Systems Development Facility (PSDF) is a joint Department of Energy/Industry sponsored engineering-scale facility for testing advanced coal-based power generation technologies. High temperature, high pressure gas cleaning is critical to many of these advanced technologies. Barrier filter elements that can operate continuously for nearly 9000 hours are required for a successful gas cleaning system for use in commercial power generation. Since late 1999, the Kellogg Brown & Root Transport reactor at the PSDF has been operated in gasification mode. This paper describes the test results for filter elements operating in the Siemens-Westinghouse particle collection device (PCD) with the Transport reactor in gasification mode. Operating conditions in the PCD have varied during gasification operation as described elsewhere in these proceedings (Martin et al, 2002).

2002-09-19

356

The full scope simulator hardware I/O realization in Daya bay nuclear power station  

International Nuclear Information System (INIS)

The full scope simulator in Daya Bay Nuclear Power Station is imported from THOMSON-CSF company in France. It is a large facility, using digital simulation technology, that simulate the main control room of Daya Bay Nuclear Power Station with the high fidelity. It is used for training operators; system analyzing including operation procedure verification. The input output interface system of the simulator is the bridge of the information exchange between instrumentation and the computer. From the point of view of data transfer, this paper discusses the operation principle of the I/O interface system.

357

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

358

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

359

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

360

CLEO: a knowledge-based refueling assistant at FFTF  

International Nuclear Information System (INIS)

A computer software system, CLEO, is used to assist in the planning and performance of the reactor refueling operations at the Fast Flux Test Facility (FFTF). It is a recently developed application of artificial intelligence software with both expert systems and automated reasoning aspects. CLEO, an acronym for Cloned LEO, is a logic-based computer program written in Pascal. It imitates the processes that the refueling expert for FFTF performs in organizing the refueling of FFTF. The computer assistant seeks to organize the sequence of core component movements according to the rules and logic used by the expert. In this form, CLEO has aspects that tie it to both the expert systems and automated reasoning areas within the artificial intelligence field.

1985-11-10

361

The Biogas/Biofertilizer Business Handbook. Third Edition. Appropriate Technologies for Development. Reprint R-48.  

Science.gov (United States)

This book describes one approach to building and operating biogas systems. The biogas systems include raw material preparation, digesters, separate gas storage tanks, use of the gas to run engines, and the use of the sludge as fertilizer. Chapters included are: (1) "Introduction"; (2) "Biogas Systems are Small Factories"; (3) "The Raw Materials of Biogas Digestion"; (4) "The Daily Operation of a Biogas Factory"; (5) "The Once a Year Cleaning of the Digester"; (6) "Tanks and Pipes: Storing and Moving Biogas"; (7) "The Factory's Products: Biogas"; (8) "The Factory's Products: Biofertilizer"; (9) "The ABCs of Safety"; and (10) "Conclusion: Profiting from an Appropriate Technology." Many diagrams are provided throughout this handbook. New ideas, composting, bioinsecticides, ferrocement, facts and figures, sources and resources, feasibility studies, problem solving, and vocabulary are presented in the ...

1985-07-01

362

PWM applications for the electric railway traction system fed by the AC/DC dual power line  

Energy Technology Data Exchange (ETDEWEB)

The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the auxiliary power supply can be obtained from multiple line converters using diodes. As the result of the ...

1996-01-01

363

Method for controlling a coolant liquid surface of cooling system instruments in an atomic power plant  

International Nuclear Information System (INIS)

Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which is provided with an overflow ...

364

Canadian upstream oil and gas industry fire and explosion incident analysis based on the investigative work of the IRP18 Committee working with the University of Calgary Department of Chemical and Petroleum Engineering. Revision 1  

Energy Technology Data Exchange (ETDEWEB)

This report presented an analysis of incidents gathered by the Canadian upstream oil and gas industry committee in relation to explosive atmospheres in wellbores, vessels, tanks, and piping systems. The aim of the report was to develop industry recommended practices for oil and gas industry fires and explosions. Two accident theory models were used to set out the relationships between hazards, defenses, and losses. Three levels of defenses were identified based on organizational, local workplace, and human factors. An organizational responsibility approach was used to examine the activities of key people with the system. Incidents were analyzed based on an expanded fire triangle used to identify fire and explosion hazards. The study showed that the ignition of hydrocarbons into the air was a factor in nearly 50 per cent of the incidents. A lack of understanding of liquid-hydrocarbon properties was demonstrated in incidents ...

2005-05-15

365

CATHENA simulation of the WOLSUNG D_20 spill incident of 1984 November 25  

International Nuclear Information System (INIS)

The CATHENA (formerly ATHENA) has been used to simulate the thermalhydraulic behaviour of the WOLSUNG-1 CANDU-600 reactor during the D_20 spill incident of 1984 November 25. A 4-inch (nominal) Liquid Relief Valve inadvertently opened in the reactor auxiliary system during normal reactor operation, resulting in a discharge of heavy water from the primary heat transport system. The valve remained open for approximately 29 minutes. CATHENA is an advanced thermalhydraulic computer code for analysis of postulated loss-of-coolant accidents (LOCA) and transient faults in CANDU nuclear reactors. A full two-fluid (six-equation) representation of the two-phase flow is used. Component models are used to represent pumps, valves, critical discharge, etc., which are necessary to describe the behaviour of the CANDU system under upset conditions. Heat transfer between the fluid and piping walls (or fuel) is modelled ...

1986-06-09

366

Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 3. Evaluation of potential for pipe breaks  

Energy Technology Data Exchange (ETDEWEB)

The Executive Director for Operations (EDO) in establishing the Piping Review Committee concurred in its overall scope that included an evaluation of the potential for pipe breaks. The Pipe Break Task Group has responded to this directive. This report summarizes a review of regulatory documents and contains the Task Group's recommendations for application of the leak-before-break (LBB) approach to the NRC licensing process. The LBB approach means the application of fracture mechanics technology to demonstrate that high energy fluid piping is very unlikely to experience double-ended ruptures or their equivalent as longitudinal or diagonal splits. The Task Group's reommendations and discussion are founded on current and ongoing NRC staff actions as presented in Section 3.0 of this report. Additional more detailed comments and discussion are presented in Section 5.0 and in Appendices A ...

1984-11-01

367

Refinement and evaluation of crack-opening-area analyses for circumferential through-wall cracks in pipes  

Energy Technology Data Exchange (ETDEWEB)

Leak-before-break (LBB) analyses for circumferentially cracked pipes are currently being conducted in the nuclear industry to justify elimination of pipe whip restraints and jet impingement shields which are present because of the expected dynamic effects from pipe rupture. The application of the LBB methodology frequently requires calculation of leak rates. These leak rates depend on the crack-opening area of a through-wall crack in the pipe. In addition to LBB analyses, which assume a hypothetical flaw size, there is also interest in the integrity of actual leaking cracks corresponding to current leakage detection requirements in NRC Regulatory Guide 1.45, or for assessing temporary repair of Class 2 and 3 pipes that have leaks as are being evaluated in ASME Section 11. This study was requested by the NRC to review, evaluate, and refine current analytical models for ...

1995-04-01

368

Four-inch pipe whip test under BWR LOCA conditions effect of overhang length  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the test pipe and restraints becomes large with ...

1983-03-01

369

Cracking resistance in steam pipe fittings having various microdamage levels  

Energy Technology Data Exchange (ETDEWEB)

Cracking resistance and metal damage are considered in relation to structural state for steam-pipe fittings during use. An approximate scheme is given for estimating the maximum permissible operating time in the plastic state in relation to the depth of an observed crack-type defect.

1995-05-01

370

Thermal and heat transfer characteristics in a latent heat storage system using lauric acid  

Energy Technology Data Exchange (ETDEWEB)

The thermal and heat transfer characteristics of lauric acid during the melting and solidification processes were determined experimentally in a vertical double pipe energy storage system. In this study, three important subjects were addressed. The first one is temperature distributions and temporal temperature variations in the radial and axial distances in the phase change material (PCM) during phase change processes. The second one is the thermal characteristics of the lauric acid, which include total melting and total solidification times, the nature of heat transfer in melted and solidified PCM and the effect of Reynolds and Stefan numbers as inlet heat transfer fluid (HTF) conditions on the phase transition parameters. The final one is to calculate the heat transfer coefficient and the heat flow rate and also discuss the role of Reynolds and Stefan numbers on the heat transfer parameters. The experimental results proved that the PCM melts ...

2002-12-01

371

Report on commissioned business for fiscal 1997. Development of new power storage system for cells and development of technology for distributed power storage (research for a zinc/air cell system for automobiles); 1997 nendo itaku gyomu hokokusho. Shingata denchi denryoku chozo system kaihatsu bunsangata denryoku chozo gijutsu kaihatsu (denki jidoshayo aen kuki denchi system chosa)  

Energy Technology Data Exchange (ETDEWEB)

Concerning the above, it is discussed whether such a system is feasible in Japan. A zinc/air cell system requires some special plants for zinc regeneration, etc. It is necessary to build a zinc refining plant and to install dozens of electrode replacing facilities in an area dozens of kilometers in diameter with the plant at the center. For such a system to be functional, there have to be several tens of thousands of automobile users in a limited area. In Japan, so large a number will not be found anywhere even if the appeal is directed to those in the postal service and electric utilities. There will be no economic success in Japan, different from in Germany. As for the economic comparison between a zinc/air cell system and natural gas system, the two will be equivalent to each other as far as the use of the quick filling stations for the natural gas ...

1998-03-01

372

Structural integrity evaluation of fuel test loop submerged in water subjected to postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

The structural integrity of the Fuel Test Loop(FTL) in a Korean experimental reactor is evaluated when the FTL, submerged in a water environment, is subjected to a postulated pipe rupture. The analyses are performed under static and dynamic conditions, imposing the thrust force history at each postulated pipe rupture section. Through analysis the following results are found: 1) A double ended guillotine can not be expected based on the toughness of the material, 2) the structural integrity of the chimney surrounding the FTL would not impede the structural integrity by the pipe whip. All analyses are performed by finite element methods.

2000-02-01

373

Fording Coal reduces preparation plant downtime with wear resistant lining  

Energy Technology Data Exchange (ETDEWEB)

Prior to 1986, the abrasive coking coal processed in the coal preparation plant at the Fording River operation at Elkford, British Columbia, was destroying the mild steel straight pipe and elbows at such a rate that they were having to be replaced annually and every 6-8 months respectively. To solve the problem, Fording River began to replace existing pipe and elbows with fused-cast, basalt-lined abrasion-resistant pipe, elbows and fittings manufactured by Abresist Corp. of Urbana, Indiana. The Abresist straight pipe has lasted 7 seven years and the Abresist elbows 5 years and both are still in use. 2 photos.

1994-04-01

374

Failure analysis on a ruptured petrochemical pipe  

Energy Technology Data Exchange (ETDEWEB)

The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

2010-08-15

375
376

BURST STRENGTH AND NON-DESTRUCTIVE EVALUTION OF COMPOSITE PIPES AND PIPE COUPLINGS WITH DEFECTS (TOP 48)  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...

1996-01-31

377

Through Weld Inspection of Wrought Stainless Steel Piping Using Phased Arrays  

Energy Technology Data Exchange (ETDEWEB)

Outline: Discuss far-side weld problem and phased array techniques applied. Describe laboratory work on flawed piping specimens using L- and S-wave arrays and provide synopsis of results. Discuss conclusions ofr capability of phased array as applied to austenitic welds. Research Approach: Evaluate phased arrays on unifornly-welded piping specimens. Apply best methods to non-uniform welds. Correlate acoustic responses as function of weld microstructures.

2004-12-31

378

Study on the evaluation of vibration effect and the development of vibration reduction method for Wolsung unit 1 main steam piping.  

Science.gov (United States)

The main steam piping of nuclear power plant which runs between steam generator and high pressure turbine has been experienced to have a severe effect on the safe operation of the plant due to the vibration induced by the steam flowing inside the piping. ...

1996-01-01

379

Structural integrity evaluation of FTL in-pool piping  

Energy Technology Data Exchange (ETDEWEB)

HANARO fuel test loop will be equipped in HANARO to obtain the development betterment of advanced fuel and materials through the irradiation test. The object of this study is to evaluate the structural integrity of FTL in-pool piping by investigating a dynamic analysis of the loop containing a postulated rupture section. The method to perform the dynamic analysis and structural integrity evaluation caused by the pipe whip in water environment can be a reference for a similar structural integrity evaluation. (author). 7 refs., 39 tabs., 34 figs.

1998-05-01

380

Heat pipes and two-phase loops with capillary pumping; Caloducs et boucles diphasiques a pompage capillaire  

Energy Technology Data Exchange (ETDEWEB)

This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)

1996-12-31

381

Design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1981-01-01

382

American National Standard: design basis for protection of light water nuclear power plants against effects of postulated pipe rupture  

Energy Technology Data Exchange (ETDEWEB)

This standard addresses the design bases for light water reactor, nuclear power plant structures and components essential for the protection of public health and safety from the potential adverse effects of pipe whip, jet impingement, pressurization of compartments outside containment, environmental conditions and flooding associated with a postulated pipe rupture. The design bases for missile protection and the design bases for containment pressurization are not within this standard.

1980-12-31

383

New developments in dry spent fuel storage  

International Nuclear Information System (INIS)

As shown in various new examples, HABOG facility (Netherlands), CERNAVODA (Candu - Romania), KOZLODUY (WWER - Bulgaria), CHERNOBYL ( RMBK - Ukraine), MAYAK (Spent Fuel from submarine and Icebreakers - Russia), recent studies allow to confirm the flexibility and performances of the CASCAD system proposed by SGN, both in safety and operability, for the dry storage of main kinds of spent fuel. The main features are: A multiple containment barrier system: as required by international regulation, 2 independent barriers are provided (tight canister and storage pit); Passive cooling, while the Fuel Assemblies are stored in an inert atmosphere and under conditions of temperature preventing from degradation of rod cladding; Sub-criticality controlled by adequate arrangements in any conditions; Safe facility meeting ICPR 60 Requirements as well as all applicable regulations (including severe weather conditions ...

2001-06-18

384

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period January 1, 2005 through March 31, 2005. The following tasks have been completed. First, the renovation of the new Combustion Laboratory is nearly complete, and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building is in the final stages. Second, the fabrication and manufacture of the CFBC Facility is being discussed with a potential contractor. Discussions with potential contactor regarding the availability of materials and current machining capabilities have resulted in the modification of the original designs. The selection of the fabrication contractor for the CFBC Facility is expected during the next quarter. Third, co-firing experiments conducted with coal ...

2005-04-30

385

Break Nodalization Influence to IAEA-SPE-4 Test Simulation  

International Nuclear Information System (INIS)

A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and ...

1998-06-15

386

Tank waste remediation system retrieval and disposal mission key enabling assumptions  

Energy Technology Data Exchange (ETDEWEB)

An overall systems approach has been applied to develop action plans to support the retrieval and immobilization waste disposal mission. The review concluded that the systems and infrastructure required to support the mission are known. Required systems are either in place or plans have been developed to ensure they exist when needed. The review showed that since October 1996 a robust system engineering approach to establishing integrated Technical Baselines, work breakdown structures, tank farm structure and configurations and work scope and costs has been established itself as part of the culture within TWRS. An analysis of the programmatic, management and technical activities necessary to declare readiness to proceed with execution of the mission demonstrates that the system, people and hardware will be on line and ready to support the private contractors. The ...

1998-01-05

387

Design and performance of the solar-powered floor heating system in a green building  

Energy Technology Data Exchange (ETDEWEB)

In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m{sup 2} were installed to provide heating for the covered area of 460 m{sup 2}. The floor heating coil pipes were made of high-quality pure copper with the dimension of {phi} 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the whole heating period, the solar fraction was 56%. According to ...

2009-07-15

388

Large sample NAA facility at GRR-1 research reactor: Design and applications  

International Nuclear Information System (INIS)

Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of ...

2003-06-09

389

Integrative facility management via the intranet requires reliable communication. Network and security solutions for multi-site facility management; Integratives Gebaeudemanagement ueber Intranet erfordert gesicherte Kommunikation. Network und Security Konzept fuer das technische Multi-Site-Facility-Management  

Energy Technology Data Exchange (ETDEWEB)

Since enterprises operating offices and facilities at geographically distributed sites have been establishing an intranet for inter-office communication at the management level, the idea of integrating another intranet for multi-site technological facility management comes naturally. The Aachen-based technology enterprise Eurem for this purpose developed a Network and Security concept with solutions that can be customized for linking a variety of computerized control and monitoring systems. The package includes a modular substation named modUS, which is open to the field side as well as to the management side, is capable of efficiently and reliably performing the facility management functions by way of remote controlling via intranets. (orig./CB) [Deutsch] Nachdem in den Unternehmen mit verteilten Liegenschaften die unterschiedlichsten Buerokommunikationssysteme ueber eigene Netzwerke verbunden werden, ...

1999-02-08

390

Tanker-based production eyed for Gulf of Mexico use  

Energy Technology Data Exchange (ETDEWEB)

The new oil price environment is sending industry engineers back to the drawing board. The search is on for cost effective and perhaps unconventional deepwater production systems. One candidate for Gulf of Mexico deepwater tracts is a tanker-based floating production, storage, and offloading (FPSO) system. Substantial experience with tanker-based FPSO systems has proven them to be cost effective when the field is remote from existing production facilities and pipelines. A tanker-based system offers the unique feature of integrating production, storage, and offloading capabilities into a single unit. Such systems can be installed in 12 to 15 months and can even be leased, significantly improving an operator's cash flow.

1986-05-01

391

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can ...

1976-06-13

392

Decomissioning Strategies for Facilities Using Radioactive Material  

CERN Document Server

Decomissioning Strategies for Facilities Using Radioactive Material

2007-01-01

393

Tap cogen-plant steam for process, NO[sub x] control  

Energy Technology Data Exchange (ETDEWEB)

This article describes the Monsanto's Indian Orchard plant gas-fired, combined-cycle cogeneration facility in Springfield, Massachusetts. The topics of the article include project configuration, the thermodynamic cycle, fuel selection, electrical distribution system, plant control, and air pollution control of NO[sub X], SO[sub 2], CO, particulates, non-methane hydrocarbons, opacity and ammonia.

1993-04-01

394

Performance testing of the FMC Fresnel-Belt Concentrating Solar Collector  

Energy Technology Data Exchange (ETDEWEB)

The results of tests performed on the FMC Fresnel-Belt Solar Collector at the Midtemperature Solar Systems Test Facility are summarized. Tests were conducted over a temperature range from 100 to 250/sup 0/C. Test objectives are defined, test procedures are described, and test results and conclusions are given.

1980-01-01

395

Leveraging limited research and development (R&D) resources in the public sector  

Energy Technology Data Exchange (ETDEWEB)

Mission-directed public-sector research facilities are experiencing increasingly severe budget environments while seeing expanding missions and responsibilities. In an effort to identify research leveraging methodologies an information search was conducted in conjunction with some efforts to find the proper links to systems engineering fundamentals. The result is an initial model for use in a pre-concept/phase-1 engineering design organization, with a goal of improving the organizations performance.

1996-12-01

396

Levels of ICT use in teaching and administration  

DEFF Research Database (Denmark)

The computer facilities and the computer expertise at certain departments at Aalborg University made these departments natural starting points for integration of Information and Communication Technology (ICT) in their activities. This utilization and integration of ICT was not organized from the top or intermediate levels. It developed from the grassroots. Today Aalborg University as a whole can be said to be a truly ICT integrated institution. The quick development is to a high extent due to a structure with a finely distributed system of equipment, know-how and autonomy at all levels

2000-01-01

397

HVDC submarine cables for the Hokkaido Honshu linkage  

Energy Technology Data Exchange (ETDEWEB)

The direct-current submarine cable interconnecting Hokkaido and Honshu (hereafter called HH linkage) is an example of installation of an undersea cable for long-distance power transmission crossing a sea strait. In particular, the feature of this interconnection is that an oil-filled (OF) cable is used for the high-voltage side with crosslinked polyethylene (XPLE) cable adopted for the return to comprise a conductor return system. The details of the facilities, especially the design of the OF submarine cable are described. 3 refs.

1981-04-01

398

Development of a new secondary beam separator and a new gas-jet target at Kyushu University  

International Nuclear Information System (INIS)

In order to facilitate observations of low energy nuclear reactions, a new type recoil mass-separator together with a new gas-jet target system is being developed at the tandem accelerator facility in Kyushu University. The expected mass-resolving power of the separator is 220 for a solid angle of 10 msr and the practical thickness of the gas-jet target will exceed 0.1 atm#centre dot#cm for the light elements of H and He. (author).

1994-06-01

399

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

400

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

401

Annual report 1993-1994  

Energy Technology Data Exchange (ETDEWEB)

The Atlantic Wind Test Site was established in 1980 as a laboratory to facilitate the evaluation and demonstration of wind energy systems and equipment. This annual report describes its organization and management, facilities, major projects, and the outlook for the future. Major projects include wind diesel; AWTS-IREQ collaboration; remote community data acquisition; lagerwey test program; Alaska Energy Authority Project; public education; Atlantic Orient Corporation 15/50 Project; and the soft VAWT project.

1994-12-31

402

Advances in noise analysis for nuclear plant surveillance and diagnostics  

Energy Technology Data Exchange (ETDEWEB)

An automated surveillance and baseline noise signature acquisition system is being demonstrated at Sequoyah-1. A nonperturbing method is also being developed for monitoring the subcritical reactivity during initial core loading in LWRs, in fuel storage and processing facilities, and during postaccident recovery operations such as Three Mile Island-2. (DLC)

1980-01-01

403

A management scheme for reducing pollution at air discharge facility in advance  

Energy Technology Data Exchange (ETDEWEB)

The developed countries are implementing a policy minimizing damage from environmental pollution by reducing discharge in advance as well as the aftermath of a pollutant. The typical example is to use BAT (Best Available Technology). This is to prevent environmental damage by reducing the discharge of pollutants with available technology and to secure environmental margin to enable industrial activities of future generation. Therefore, the feasibility of introducing BAT requirement system was reviewed by considering foreign examples and Korean situation. 38 refs., 8 figs., 69 tabs.

1998-12-01

404

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is ...

2001-07-01

405

Implementation plan for liquid low-level radioactive waste tank systems for fiscal year 1995 at Oak Ridge National Laboratory under the Federal Facility Agreement, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This document is the third annual revision of the plans and schedules for implementing the Federal Facility Agreement (FFA) compliance program, originally submitted in 1992 as ES/ER-17&D1, Federal Facility Agreement Plans and Schedules for Liquid Low-Level Radioactive Waste Tank Systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. This document summarizes the progress that has been made to date in implementing the plans and schedules for meeting the FFA commitments for the Liquid Low-Level Waste (LLLW) System at Oak Ridge National Laboratory (ORNL). Information presented in this document provides a comprehensive summary to facilitate understanding of the FFA compliance program for LLLW tank systems and to present plans and schedules associated with remediation, through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) process, of LLLW ...

1995-06-01

406

Tensile properties and bending formability of drawn magnesium alloy pipes  

Energy Technology Data Exchange (ETDEWEB)

Magnesium alloys are being increasingly utilized in a variety of fields as an alternative material to organic materials and aluminum alloys, owing to excellent properties. Those include low density, and excellent damping properties. When compared to organic materials, furthermore, Mg alloy excels at recyclability, heat radiation, and electromagnetic-shielding. Though most of magnesium alloy products are manufactured through die-casting and thixo-molding at present, the demand for the expanding of magnesium wrought alloy market is increasing. Taking full advantage of a drawing technique and applying it to the conventional extruded pipe, we have developed a new type of magnesium alloy pipe. The strength of the developed pipe is significantly higher than that of the conventional one, either extruded or die-casting. Some of the excellent properties were obtained from fundamental tests performed with the developed ...

2003-07-01

407

High thermal load receiving heat plate  

Energy Technology Data Exchange (ETDEWEB)

The present invention concerns a high thermal load heat receiving plate such as a divertor plate of a thermonuclear device. The high thermal load heat receiving plate of the present invention has a cooling performance capable of suppressing the temperature of an armour tile to less than a threshold value of the material against high thermal loads applied from plasmas. Spiral polygonal pipes are inserted in cooling pipes at a portion receiving high thermal loads in the high temperature load heat receiving plate of the present invention. Both ends of the polygonal pipes are sealed by lids. An area of the flow channel in the cooling pipes is thus reduced. Heat conductivity on the cooling surface of the cooling pipes is increased in the high thermal load heat receiving plate having such a structure. Accordingly, temperature elevation of the armour tile can be suppressed. (I.S.).

1993-09-28

408

Energy absorbers used against impact loading  

International Nuclear Information System (INIS)

In the WWER-440 reactor the primary piping consists of six horizontal loops going radially from the pressure vessel, each loop having a horizontal steam generator. In this reactor type the relatively long primary piping with many curved sections requires special attention in order to successfully eliminate the consequences of the design basis accident. Emergency supports are located in appropriate places to restrict the movements of the pipe. Under normal conditions there is a gap of some centimeters between the pipe and a support so that in the pipe can be deformed freely under changing loads. This paper deals with those energy-absorbing structures used at the Loviisa Nuclear Power Plant for protection against impact loading. Places and circumstances where energy-absorbing structures are employed are specified. Development and design of impact absorber elements are discussed and ...

1975-09-08

409

Blowdown thrust force under pipe rupture accident. Pt. 1. Experimental evaluations of blowdown thrust force and decompression characteristics  

Energy Technology Data Exchange (ETDEWEB)

Blowdown thrust forces and decompression characteristics were evaluated concerning the jet discharge or pipe whip tests with a 4-inch or 6-inch diameter pipe under PWR LOCA or BWR LOCA conditions related to pipe rupture accidents in nuclear power plants. This paper presents experimental evaluations of time-dependent and maximum blowdown thrust forces, and evaluations of decompression characteristics under instantaneous pipe rupture conditions. The following items are discussed: the peak value of the blowdown thrust force, the jet thrust coefficient for the maximum blowdown thrust force, the pressure recovery after break, and the relationship between the pressure undershoot of the sudden decompression and the decompression rate.

1984-06-01

410

A study on the transient analysis of pipe and restraint due to impact loading  

Energy Technology Data Exchange (ETDEWEB)

In this study, experiments were performed for pipe whip phenomena simulation. The analytical method was developed by combining several kinds of elements in ABAQUS computer code, standard version 5.2 . The transient analytical and the experimental results of the pipe whip test using 6 inch diameter pipe and U-shaped restraints are presented. It is shown that the adequate clearance decreases the restraint strains. As the overhang length increased, the maximum strain of restraints decreased. When the impact force increased, the maximum restraint strain increased slightly. The analytical models simulate the experimental impact phenomena very precisely, with slight conservatism. It is verified that the analytical method developed is very suitable to pipe whip phenomena analysis in nuclear power plants. 6 refs., 10 figs., 1 tab.

1995-12-31

411

Use of explosive quick depressurization valves in the SBWR project. Dynamic loads induced by their operation  

International Nuclear Information System (INIS)

In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other important loads that are ...

412

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the ...

2006-03-01

413

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the ...

2006-03-01

414

Laboratory Evaluation of an Electrochemical Noise System for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines  

Energy Technology Data Exchange (ETDEWEB)

Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those found within gas pipelines in equilibrium ...

2003-03-16

415

Application and experience of low alloy steel main coolant lines in PWRs  

Energy Technology Data Exchange (ETDEWEB)

The significant technical and industrial aspects which have led to main coolant line (MCL) materials selection are addressed from a long term experience and operational practice point of view. They are based on the Siemens/KWU developed basic material concept for its nuclear power plants. It considers the choice of appropriate materials, the evaluation and qualification of the materials and the materials manufacturer, the use of appropriate semi-finished products, the tailoring of material and semi-finished products to the specific requirements of the various systems, the application of adequate manufacturing processes and the proof of the requirements by specifying proper tests and examinations. The main systems are assigned to safety classes in accordance with their safety relevance. Summarizing the operation time of nuclear power plants with ferritic MCL equipped by Siemens/KWU, more than 200 years of operation experience exist and no ...

1996-08-01

416

Advanced PWR technology development -Development of advanced PWR system analysis technology-  

Energy Technology Data Exchange (ETDEWEB)

The primary scope of this study is to establish the analysis technology for the advanced reactor designed on the basis of the passive and inherent safety concepts. This study is extended to the application of these technology to the safety analysis of the passive reactor. The study was performed for the small and medium sized reactor and the large sized reactor by focusing on the development of the analysis technology for the passive components. Among the identified concepts the once-through steam generator, the natural circulation of the integral reactor, heat pipe for containment cooling, and hydraulic valve were selected as the high priority items to be developed and the related studies are being performed for these items. For the large sized passive reactor, the study plans to extend the applicability of the best estimate computer code RELAP5/MOD3 which is widely used for the safety analyses of the reactor system. The improvement and ...

1995-07-01

417

Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand the functions of the existing PPS composed ...

2006-07-01

418

Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant  

International Nuclear Information System (INIS)

The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand the functions of the existing PPS composed ...

2006-05-25

419

Using the in-house telephone network for language storage purposes as additional information facility. Nutzung des Werkstelefonnetzes fuer Sprachspeicherdienste als zusaetzliche Informationseinrichtung  

Energy Technology Data Exchange (ETDEWEB)

As a first step an attempt was made to integrate a personnel information facility into a system for optimising materials flow. The two systems developed did not reach a workable stage because the synthetic language would have required an input on the part of the personnel operating the system beyond what could reasonably be expected. The research in the second stage consisted in developing and testing a module with which language storage services could be built up on the basis of digitalised speech and controlled via the in-house telephone network. In language storage services users may feed in data or interrogate. Services of this kind can readily be integrated into available telephone installations working on the pulse selection principle. The low cost of the hardware involved means the system can be built up with modest investment while offering high effectiveness. 6 refs., 2 ...

1990-06-01

420

Performance Assessment of Physical Protection System at Wolsong Nuclear Power Plant using SAVI code  

Energy Technology Data Exchange (ETDEWEB)

The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several techniques are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsong NPP using SAVI code. The first is that the SAVI constructs the site-specific Adversary Sequence Diagram (ASD) of the PPS. This provides a methods of graphically representing ...

2005-07-01

421

NATIONAL HIGH MAGENTIC FIELD LABORATORY FEL INJECTOR DESIGN CONSIDERATION  

Energy Technology Data Exchange (ETDEWEB)

A Numerical study of beam dynamics was performed for two injector systems for the proposed National High Magnetic Field Laboratory at the Florida State University (FSU) Free Electron Laser (FEL) facility. The first considered a system consisting of a thermionic DC gun, two buncher cavities operated at 260 MHz and 1.3 GHz and two TESLA type cavities, and is very similar to the injector of the ELBE Radiation Source. The second system we studied uses a DC photogun (a copy of JLab FEL electron gun), one buncher cavity operated at 1.3 GHz and two TESLA type cavities. The study is based on PARMELA simulations and takes into account operational experience of both the JLab FEL and the Radiation Source ELBE. The simulations predict the second system will have a much smaller longitudinal emittance. For this reason the DC photo gun based injector is preferred for the proposed FSU FEL ...

2007-06-25

422

Industrial HVAC: a survey of design considerations  

Energy Technology Data Exchange (ETDEWEB)

Industrial facilities offer a wide variety of design challenges to engineers, including the mechanical engineers who design the HVAC, the process, exhaust, and other required mechanical systems; the mechanical contractors who install and maintain the systems (and who also may do design work); and the owners` engineers who are responsible for the day-to-day operation of their facilities. Along with the responsibility to see that all systems function as intended is the responsibility to ensure that all worker health concerns are addressed. These include heat stress avoidance and the proper control of harmful substances. The services of industrial hygienists may be required to ensure this. These may be independent consultants or the staff members of mechanical design firms. In addition, it is not unusual for major corporations that own manufacturing plants to have staff industrial ...

1996-11-01

423

Evolutionary developments advancing the floating production, storage, and offloading concept  

Energy Technology Data Exchange (ETDEWEB)

Tanker-based floating production, storage, and offloading (FPSO) systems have been in operation since Aug. 1977, when a single-well FPSO facility was put into production by Shell Espana in the Mediterranean. The overall operational experience with this system at this field is reviewed, with special attention to the wireline workover facilities, which have proved very satisfactory. A subsequent evolutionary step, a FPSO system accommodating multiple wells, necessitated development of a multibore fluid swivel. A design program for this swivel was initiated in 1978; a prototype was built and full-scale testing finalized in 1980. A summary of the test results is presented. Simultaneously with the multibore swivel development, detailed engineering for an eight-well FPSO unit was begun. This system includes gas-lift and water injection capabilities. Provisions for ...

1983-04-01

424

Environmental Restoration Project quality system requirements for the Hanford Site. Revision 3  

International Nuclear Information System (INIS)

This document defines the quality system requirements for the US Department of Energy, Richland Operations Office (DOE-RL), Environmental Restoration (ER) Project at the Hanford Site. The Environmental Restoration Project Quality System Requirements for the Hanford Site integrates quality assurance requirements from the DOE Orders, the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), the Hanford Facility Resource Conservation and Recovery Act of 1976 (RCRA) Permit, and applicable Federal and Washington State regulations. This document, based on ten criteria, provides user organizations with the flexibility to incorporate only those criteria and paragraphs applicable to their specific scopes of work. The requirements of this document are to be applied based on a graded approach that takes into consideration the risk inherent in, as well as the importance of, specific items, ...

425

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This purpose of this report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period April 1, 2005 through June 30, 2005. The following tasks have been completed. First, the new Combustion Laboratory was occupied on June 15, 2005, and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building is in the final painting stage. Second, the fabrication and manufacturing contract for the CFBC Facility was awarded to Sterling Boiler & Mechanical, Inc. of Evansville, Indiana. Sterling is manufacturing the assembly and component parts of the CFBC system. The erection of the CFBC system is expected to start September 1, 2005. Third, mercury emissions from the cofiring of coal and chicken waste was studied experimentally ...

2005-07-30

426

Conawapa to Winnipeg Power Transmission Complex. Southern Receiver System: Environmental impact assessment status report  

International Nuclear Information System (INIS)

Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmission lines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations affected by the upgrade. ...

1992-01-01

427

Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia  

Energy Technology Data Exchange (ETDEWEB)

This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions ...

2005-04-15

428

FFTF fission gas monitor computer system  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or ...

429

VACUJET-process - high pressure water jet technology with broad application potential; VACUJET-Verfahren - Wasserhoechstdrucktechnik mit grossem Einsatzpotential  

Energy Technology Data Exchange (ETDEWEB)

When performing trenchless pipe renovation work - whichever process you use - the success of the job depends on the careful removal of all scale, sediments and rust from the innerwall surfaces. The VACUJET process - in which the pipe is cleaned with water at pressures of up to 2 500 bar using a technique jointly developed by Preussag Rohrsanierung GmbH and Fabex GmbH - meets all requirements. The equipment includes a mobile waste water treatment unit which is small enough to fit on a standard trailer. Despite its compact dimensions this plant is so effective that it can treat all the waste water generated during the high pressure cleaning jobs so that it is suitable for reuse in the cleaning process or for release into the sewerage system. (orig.) [Deutsch] Bei der grabenlosen Rohrsanierung, ganz gleich nach welchem Verfahren saniert wird, ist die sorgfaeltige Entfernung von alten Beschichtungen, Ablagerungen und Rost eine ...

1998-12-31

430

Mitigating aging in CANDU plants  

Energy Technology Data Exchange (ETDEWEB)

Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which would impact negatively ...

1995-07-01

431

Evaluation of cathodic dis-bonding of three types of coatings by DC and AC methods  

Energy Technology Data Exchange (ETDEWEB)

For the protection of buried steel pipeline, it is common practice to coat the pipelines with highly insulating coating and apply a cathodic current to insulate the pipe from the aggressive environment. Cathodic current protects holidays or damaged area of coating which required less current than would be needed for an uncoated pipe, but because of the cathodic reactions evolution will be taken H{sub 2} and OH{sup -} on holidays which exposed metal to the environment place. This effect is to cause loss bond of coating around the holidays called cathodic dis-bonding. In this paper we measured cathodic dis-bonding of three types of coatings at - 1.5 V(Cu/CuSO{sub 4}) according to ASTM G8. We studied on cathodic dis-bonding resistance of petroleum-base, coal tar-base and polyethylene plastic tape coatings. After 30 days immersion in electrolyte it was found that the cathodic disbanding resistance of polyethylene plastic tape coating is lower than ...

2004-07-01

432

Nonlinear dynamic analysis of pipe whip tests. Final report  

Energy Technology Data Exchange (ETDEWEB)

This is a numerical verification of two groups of pipe whip tests sponsored or cosponsored by EPRI. Experimental data of the two pipe whip tests, one by Tennessee Valley Authority (TVA) and by FRAMATOME/CEA, were provided by EPRI. A nonlinear finite element code, ABAQUS-EPGEN, developed under partial sponsorship by EPRI was used for modeling the pipe whip tests. Beam elements together with an equivalent nonlinear spring element or a partial shell mesh were used to model pipes and elbow in the pipe whip tests. Material nonlinearity due to plasticity, strain rate effects, and temperature, as well as geometric nonlinearity due to large rotation and boundary conditions were included in the study. Effects of strain rate and modeling techniques were assessed. Results by current industry approach were also included as a reference solution. This report can be used as a guideline for ...

1986-05-01

433

Waste management systems model for energy systems sites on the Oak Ridge Reservation  

Energy Technology Data Exchange (ETDEWEB)

There is a model on the Oak Ridge Reservation which provides requirements for determining capacities and capabilities related to low-level, hazardous, and mixed wastes. In FY 1987, the model will be sufficiently advanced to provide various waste management scenarios. These scenarios will be compared technically, operationally, and financially by use of waste characterization data and process simulators that are currently under development. The results of the process simulations will be used to help identify waste treatment, storage, and disposal technologies that need to be demonstrated prior to full-scale development for DOE use. The information derived from this effort will be made available to all DOE facilities.

1986-01-01

434

Some implications of cancelled construction plans  

Energy Technology Data Exchange (ETDEWEB)

This article addresses the possibility that electric utilities may not have enough generating capacity to meet the demands on their systems at some future date as a result of a recent spate of plant-construction cancellations, especially of nuclear facilities. It emphasizes that, when that time arrives, utilities will be willing to try every conceivable possibility for preserving the integrity of their systems, and offers differential pricing of electricity as one such possibility. The article also offers a regional analysis of the effect of plant cancellations and of the potential for differential pricing as a preventative of power shortages. 5 tables.

1982-08-19

435

Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A  

Energy Technology Data Exchange (ETDEWEB)

Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

1986-10-01

436

Renewable energy systems for rural areas  

International Nuclear Information System (INIS)

In the rural areas, especially those located far enough from infrastructure facilities (highways and national roads, electricity and gas networks, etc.), energy supply (both quantitatively and qualitatively) is scarcer than in the urban ones. The purpose of this paper is to analyse the use of renewable energy hybrid systems in order to increase the quality and the quantity of energy supplied to the rural settlements. The paper is thus a guide of how to choose the appropriate energy source with higher potential and efficiency, minimal capital and operational costs and better comfort. (authors)

2007-11-22

437

Proceedings of the Areva Technical Days. Session 5  

Energy Technology Data Exchange (ETDEWEB)

This document presents the proceedings of the Areva technical days, presented during the session 5 the 9 and 10 december 2004, at Istanbul. It deals with the operations of the transmission and distribution division. With manufacturing facilities in over 40 countries and a sales network in over 100, Areva offers customers technological solutions for nuclear power generation and electricity transmission and distribution (the Group also provides interconnect systems to the telecommunications, computer and automotive markets). It provides five topics: a general presentation of Areva, the strategic stakes for transmission and distribution by world-zone, economic and strategic stakes of business unit products, business unit systems and business unit automation. (A.L.B.)

2004-07-01

438

Proceedings of national conference on operating experience of nuclear reactors and power plants: book of preprints  

International Nuclear Information System (INIS)

The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)

2006-11-13

439

Operational status of the Brookhaven National Laboratory Accelerator Test Facility  

International Nuclear Information System (INIS)

Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2#pi#/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures.

1990-06-11

440

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).

1985-02-01

441

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.

1985-02-01

442

Integrated planning problem in supply chains with time-varying delivery  

British Library Electronic Table of Contents (United Kingdom)

We consider a serial supply chain consisting of a raw material supplier, a manufacturer, a distribution centre and a retailer in the presence of time-varying delivery between manufacturer facility and the retailer warehouse. Delivery time functions are developed based on practical data analysis and the cost models for both linear and non-linear delivery time functions are derived. Analytic solution for system with linear delivery times is derived and a search algorithm for system with non-linear delivery times is established. Finally, sensitivity analysis is made to help decision makers achieve a lower total cost in practice.

2011-01-01

443

Development of the SRS environmental counting laboratory gamma spectroscopy system  

International Nuclear Information System (INIS)

The Savannah River Site (SRS), one of several U.S. Department of Energy (DOE) facilities, produces nuclear materials for national defense and for other government and civilian uses. SRS ceased production of defense materials in 1988, and the site's main activities now involve waste management and environmental restoration. These programs have generated extensive effluent monitoring and environmental surveillance programs for the Environmental Monitoring Section (EMS), which performs #approx#105,000 radiological analyses on 30,000 samples a year. Gamma spectroscopy is performed on an estimated 10,000 samples annually. This report describes a program to develop and improve the EMS system.

1996-06-16

444

Decommissioning and dismantling. Examination of the radiation hardening of electronic components. Final report  

International Nuclear Information System (INIS)

Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).

445

Stability and disturbance of large dc superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.

1981-11-11

446

Reduction of statistic error in Mihalczo subcriticality measurement  

Energy Technology Data Exchange (ETDEWEB)

The theoretical formula for the statistical error estimation in Mihalczo method was derived, and the dependence of the error were investigated on the facility to be measured and on the parameter in the data analysis. The formula was derived based on the reactor noise theory and the error theory for the frequency analysis, and found that the error depends on such parameters as the prompt neutron decay constant, detector efficiencies, and the frequency bandwidth. Statistical errors estimated with the formula was compared with experimental values and verified to be reasonable. Through parameter surveys, it is found that there is an optimum combination of the parameters to reduce the magnitude of the errors. In the experiment performed in DCA subcriticality measurement facility, it is estimated experimentally that the measurement requires 20 minutes to obtain the statistic error of 1% for the keff 0.9. According to the error theory, this might be ...

1998-08-01

447

Radiological operating experience at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.

1987-04-22

448

Operational procedures - industry observations and opportunities for improvement  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to relate some of the commonly encountered problems with operational procedures in the nuclear industry and offer practical suggestions for their elimination. The paper is based on recent consultant experience in assisting industry clients with human performance related design and assessment initiatives. Operational procedures are a key part of an integrated system design. Procedures provide the specified instructions for actions people are to undertake in operating a facility to achieve production and safety goals. While organizations continue to make substantial investments in procedure development and maintenance, problems with procedures continue to occur, as evidenced through operating inefficiencies, errors, and events. The paper reviews the role procedures play in facility operations, comments on current development and maintenance practices, discusses the extent of human performance ...

2003-07-01

449

Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)

2011-01-15

450

Neutron cross-sections for next generation reactors: New data from n_TOF  

International Nuclear Information System (INIS)

In 2002, an innovative neutron time-of-flight facility started operation at CERN: n_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n_TOF is presented, together with plans for new measurements related to nuclear industry.

2008-06-22

451

Session 1: Geothermal Pumping Systems and Two-Phase Flow Studies  

Energy Technology Data Exchange (ETDEWEB)

Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through ...

1983-12-01

452

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

453

Low power flux logging system for TAPS 3 and 4  

International Nuclear Information System (INIS)

This system provides data logging facility for axial profile and dynamic profile experiments during low power physics experiments. The data from Cobalt Self Powered Neutron Detectors (SPNDs) are logged via hardware consisting of PC plug-in cards and data of vanadium SPNDs are logged from the Flux Mapping System (FMS) network (multicast data). The data along with programmable details of the experiment is transferred to an Access Database. The system provides online displays and extensive reports from the Access Database as per the requirement from Reactor Physicists. This paper briefly describes the evolvement of requirements (from the experience of operation of TAPS 4 to TAPS 3), software architecture and design. (author)

2010-02-01

454

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of ...

455

Electronic imaging system for neutron radiography at a low power research reactor  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-15

456

Electronic imaging system for neutron radiography at a low power research reactor  

International Nuclear Information System (INIS)

This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

2010-08-01

457

Design and installation of a low particulate, ultrahigh vacuum system for a high power free-electron laser  

International Nuclear Information System (INIS)

A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.

1999-03-01

458

Cleaning up DOE`s weapons sites: Issues of organization and management  

Energy Technology Data Exchange (ETDEWEB)

Many Department of Energy facilities across the United States are seriously contaminated with radioactive and other hazardous wastes. Decades of focus on weapons production and inadequate attention to long-term solutions for dealing with those wastes have resulted in tremendous problems. The Department of Energy recognizes the seriousness of those problems and is addressing them. In some cases existing management systems are being used to accomplish the new mission of environmental cleanup, and in other cases new systems have been created to help carry out that mission. Widespread criticism of those efforts to data are evidence that the management systems being used may not be appropriate for the job. In particular, it appears that some management systems aren`t producing desired results because they are not well aligned with the people and tasks for whom they are intended, and ...

1994-04-01

459

A Review of the IAEA Vulnerability Assessment Level Scheme: Applicabiliy to DTRA and DOE Programs in the FSU  

Energy Technology Data Exchange (ETDEWEB)

The International Atomic Energy Agency (IAEA) plans to use the Common Criteria, as the tool for developing graded and measurable evaluation criteria for information technology (IT) in safeguards systems in facilities subject to IAEA inspection. In their draft paper [ITSECSES] the IAEA defines a three-tiered Vulnerability Assessment Level (VAL) scheme. Each increased VAL level (1-3) defines additional and more stringent security and security-related requirements for the system developer, the system evaluator (assessor or authenticator), and for the IAEA. When all parties meet all requirements for a particular VAL level, IAEA has a measurable degree of confidence in the secure and proper operation of an IT system.

2001-12-06

460

Preliminary investigation of /sup 252/Cf-driven neutron noise analysis for subcritical fuel solution systems  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory ...

1981-01-01

461

Pacific Northwest Laboratory FY 1993 Site Maintenance Plan for maintenance of DOE nonnuclear facilities  

Energy Technology Data Exchange (ETDEWEB)

This Site Maintenance Plan has been developed for Pacific Northwest Laboratory's (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; ...

1992-09-28

462

Pacific Northwest Laboratory FY 1993 Site Maintenance Plan for maintenance of DOE nonnuclear facilities  

Energy Technology Data Exchange (ETDEWEB)

This Site Maintenance Plan has been developed for Pacific Northwest Laboratory`s (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; Maintenance ...

1992-09-28

463

Liuhua 11-1 development -- Design and fabrication considerations for the FPSO Nanhai Sheng Li  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development, design, and fabrication of the crude oil process facilities, and the conversion of an existing tanker for use at the Liuhua 11-1 Field. Over a 16-month period spanning 1994 and 1995, Amoco Orient Petroleum Company, and partners, China Offshore Oil Nanhai East Corporation (CONHE), and Kerr-McGee China Petroleum Ltd., converted a crude oil tanker originally built in 1975 to the Nanhai Sheng Li, the floating production, storage and offloading (FPSO) facility for the Liuhua 11-1 Field. The FPSO will process up to 65,000 BOPD produced from 20 subsea wells located 1.7 miles away. In addition to the processing facilities for produced oil and water, the FPSO has a processed crude oil storage capacity of 715,000 bbls. The ship`s propulsion system was removed during the conversion, because the FPSO is permanently moored at site by means of a 10-point, ``soft`` mooring. The ...

1996-12-31

464

The operation status and prospect of radioisotope production facility in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power ...

2008-11-15

465

Use of selective catalytic reduction for control of NO{sub x} emissions from power plants  

Energy Technology Data Exchange (ETDEWEB)

This report describes selective catalytic reduction (SCR) technologies which offer an economical and effective means of reducing nitrogen oxide emissions from electricity generation facilities and reviews the feasibility and cost effectiveness of employing this technology on electricity generating facilities in Ontario. Based on experiences in the United States, in British Columbia, and internationally in Japan and Germany, the indication is that the technology for the installation of SCR systems on new gas-fired combined cycle power plants and existing coal-fired power plants has grown enormously during the past decade, and has been established as the control technology of choice for nitrogen oxide emissions. It is widely acknowledged to reduce power plant nitrogen oxide emissions, and do so at a very reasonable incremental cost. It is estimated that the annualized cost of installing and operating a SCR at a large ...

1999-07-01

466

Summary of the Waste Management Programs at uranium recovery facilities as they relate to the 40 CFR Part 192 standards  

International Nuclear Information System (INIS)

This study evaluates the degree to which surface impoundments at licensed facilities comply with significant changes in NRC requirements initiated by enactment of EPA's final environmental standards for uranium recovery facilities (40 CFR Part 192). Impoundment liner requirements, ground-water protection standards, ground-water monitoring and corrective action programs, and site closure standards are the most significant regulatory modifications. The compliance status of 30 conventional mills and 31 in-situ mines is determined from a review of Nuclear Regulatory Commission and agreement state docket files through November, 1983. Results of this review show that a majority of conventional uranium mill tailings management systems are deficient with respect to liner requirements for new impoundments or proposed expansions to existing impoundments, as well as with respect to some aspects of ground-water monitoring and ...

467

Sampling and Analysis at the Vortec Vitrification Facility in Paducah, Kentucky. Semiannual report, November 1, 1996--March 31, 1997  

Science.gov (United States)

The Vortec Cyclone Melting System (CMS) facility; to be located at the U.S. Department of Energy (DOE) Paducah Gaseous Diffusion Plant, is designed to treat soil contaminated with low levels of heavy metals and radioactive elements, as well as organic waste. The primary components of Vortec`s CMS are a counter rotating vortex (CRV) reactor and cyclone melter. In the CMS process, granular glass forming ingredients and other feedstocks are introduced into the CRV reactor where the intense CRV mixing allows the mixture to achieve a stable reaction and rapid heating of the feedstock materials. Organic contaminants in the feedstock are effectively oxidized, and the inert inorganic solids are melted. The University of North Dakota Energy {ampersand} Environmental Research Center (EERC) has been contacted to help in the development of sampling plans and to conduct the sampling at the facility. This document is written in a format ...

1997-12-31

468

Reliability assessment of shut-off rod drive mechanism for TAPP - 3 and 4 and critical facility through life cycle testing  

International Nuclear Information System (INIS)

Shut-off rod drive mechanism forms a safety critical system of a nuclear reactor. It is the space constraints for the given reactor layout, which makes design of shut-off rod drive mechanism (SRDM) a custom built design. Design of SRDM adopts fail-safe, replaceability and the simplicity criterion ensuring very high reliability of its operation. Shut-off rod drive mechanism for TAPP-3 and 4 and 'Critical Facility' have been recently designed and developed at Division of Remote Handling and Robotics (DRHR), BARC. These are designed with a number of advanced features and these are significantly different than those used in Dhruva and 220 MWe PHWRs. Design of SRDM is qualified through proto typing and life cycle testing on a full-scale test set-up. This paper gives details of qualification and life cycle test data for prototype SRDM for TAPP-3 and 4 and 'Critical Facility' and reliability assessment. (author)

2005-12-01

469

Registration of Hanford Site Class V underground injection wells  

Energy Technology Data Exchange (ETDEWEB)

This document was requested by the Washington State Department of Ecology. Based on the State Underground Injection Control Program, as described in the Washington Administrative Code, French drains and reverse wells are being registered as Class V wells. Information on out-of-service French drains, out-of-service reverse wells, and out-of-service cribs that are deeper than their largest surface dimension is also provided. The data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. The facilities listed in WIDS as inactive have all been listed as ''out-of-service.'' Information concerning the deactivation method for a ...

1988-05-01

470

Plutonium Finishing Plant safety evaluation report  

Energy Technology Data Exchange (ETDEWEB)

The Plutonium Finishing Plant (PFP) previously known as the Plutonium Process and Storage Facility, or Z-Plant, was built and put into operation in 1949. Since 1949 PFP has been used for various processing missions, including plutonium purification, oxide production, metal production, parts fabrication, plutonium recovery, and the recovery of americium (Am-241). The PFP has also been used for receipt and large scale storage of plutonium scrap and product materials. The PFP Final Safety Analysis Report (FSAR) was prepared by WHC to document the hazards associated with the facility, present safety analyses of potential accident scenarios, and demonstrate the adequacy of safety class structures, systems, and components (SSCs) and operational safety requirements (OSRs) necessary to eliminate, control, or mitigate the identified hazards. Documented in this Safety Evaluation Report (SER) is DOE`s independent review and evaluation ...

1995-01-01

471

Innovative coke oven gas cleaning system for retrofit applications. Quarterly environmental monitoring report No. 2, July 1, 1991--September 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a summer and a winter period following the successful startup and Operational phase of the completed ...

1992-09-21

472

Innovative coke oven gas cleaning system for retrofit applications  

Energy Technology Data Exchange (ETDEWEB)

The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a summer and a winter period following the successful startup and Operational phase of the completed ...

1992-09-21

473

Industrial applications of the Jefferson Lab high-power free-electron laser  

International Nuclear Information System (INIS)

In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities ...

1998-09-02

474

FY05-FY06 Advanced Simulation and Computing Implementation Plan, Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the safety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program will require the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment and certification, to ...

2004-07-19

475

Air conditioning system planning for Kanagawa Science Park (KSP) building. Kanagawa Science Park (KSP) no kuki chowa setsubi  

Energy Technology Data Exchange (ETDEWEB)

Urban type R D (research and development) facilities have research institute functions which are not desirable to coexist in a city as compared with suburban R D facilities. Therefore careful consideration must be given to environmental protection. KSP is the first large scale urban type R D facility in Japan. The planning and construction have been made with the theme of realization of flexibility in architecture and mechanical planning as well as realization of environmental integrity. To achieve the target so-called technical slit is built at the center of the building to provide a void space for securing natural ventilation. It is effective for provision of internal mechanical spaces without spoiling urban View air exhaust from laboratories natural ventilation for underground parking lots and decrease of damage by strong wind on the ground level. Standards are established and organization is formed for environmental ...

1991-12-05

476

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in ...

1992-03-01

477

A study on the treatment of radioactive liquid wastes using synthetic by air intake system  

International Nuclear Information System (INIS)

In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate 4.6l/hr.m"2. ...

2003-11-27

478

Treatment for dismantled radioactive solid waste from the TRIGA Mark-2 and 3  

Energy Technology Data Exchange (ETDEWEB)

Radioactive wastes are generally classified into 3 type depending on their physical property: liquid, solid and gaseous type. State-of -the art concerning liquid waste treatment has already been published; KAERI/TR-1315/99. Solid wastes classification package and treatment method will be studied to effectively manage them during the practical decommissioning work. All of the spent fuel produced during the operation of the TRIGA Mark-2 and 3 have been transported to the US last year, 1998, according to the spent fuel management strategy set-up by the US government for the non-proliferation of nuclear energy. Solid wastes are mainly all equipment existing inside of the reactors, activated concrete among the bio-shielded concrete, pipes, pimps, resin filter and it's housings, heat-exchangers, liquid waste storage tanks, to radioactive waste storage treatment facilities and so on. Solid wastes are generally low-level. They are classified ...

1999-06-01

479

Numerical Modeling of Reactive Multiphase Flow for FCC and Hot Gas Desulfurization Circulating Fluidized Beds  

Energy Technology Data Exchange (ETDEWEB)

This work was carried out to understand the behavior of the solid and gas phases in a CFB riser. Only the riser is modeled as a straight pipe. A model with linear algebraic approximation to solids viscosity of the form, {musubs} = 5.34{epsisubs}, ({espisubs} is the solids volume fraction) with an appropriate boundary condition at the wall obtained by approximate momentum balance solution at the wall to acount for the solids recirculation is tested against experimental results. The work done was to predict the flow patterns in the CFB risers from available experimental data, including data from a 7.5-cm-ID CFB riser at the Illinois Institute of Technology and data from a 20.0-cm-ID CFB riser at the Particulate Solid Research, Inc., facility. This research aims at modeling the removal of hydrogen sulfide from hot coal gas using zinc oxide as the sorbent in a circulating fluidized bed and in the process indentifying the parameters that affect the ...

2005-07-01

480

Fiscal 2000 project of inviting proposals for international joint research - invitation for international proposal (Energy conservation No.2). Achievement report on international joint study on popularization promotion of geothermal heat pump-assisted environmentally compatible heating system for Changchun City, China; 2000 nendo kokusai kyodo kenkyu teian kobo jigyo - kokusai teian kobo (Shoe No.2). Chinetsu heat pump ni yoru Chugoku Changchun shi kankyo tekigogata danbo system no fukyu sokushin ni kansuru kokusai kyodo kenkyu seika hokokusho  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term monitoring of the operating conditions, (3) measurement of subterranean heat exchanger thermal conductivity ...

2001-03-01

481

Electric utility engineer`s FGD manual -- Volume 2: Major mechanical equipment; FGD proposal evaluations; Use of FGDPRISM in FGD system modification, proposal, evaluation, and design; FGD system case study. Final report  

Energy Technology Data Exchange (ETDEWEB)

Part 2 of this manual provides the electric utility engineer with detailed technical information on some of the major mechanical equipment used in the FGD system. The objectives of Part 2 are the following: to provide the electric utility engineer with information on equipment that may be unfamiliar to him, including ball mills, vacuum filters, and mist eliminators; and to identify the unique technique considerations imposed by an FGD system on more familiar electric utility equipment such as fans, gas dampers, piping, valves, and pumps. Part 3 provides an overview of the recommended procedures for evaluating proposals received from FGD system vendors. The objectives are to provide procedures for evaluating the technical aspects of proposals, and to provide procedures for determining the total costs of proposals considering both initial capital costs and annual operating and maintenance costs. The ...

1996-03-04

482

Test facilities for hybrid and electric drive trains; Stazione di prova sistemi di trazione ibridi ed elettrici  

Energy Technology Data Exchange (ETDEWEB)

ENEA (Italian National Agency for New Technologies, Energy and the Environment) is conducting a large research and development programme on innovative vehicles with high energy efficiency and low environmental impact. In particular conducts activities on electric and hybrid vehicles. Testing and evaluation activities play a strong role in this programme. A complete characterization chain has been then defined and set up with a network of facilities which covers main testing needs for single components, subsystems and complete vehicles, in simulated and real operating conditions. The test facility which has been realised is able to experiment and fully characterise complete drive-trains (and subsystems) for pure electric and hybrid vehicles. It is composed by a different section for each subsystem: 1) power generation; 2) energy storage and management; 3) driving motors. Each section acts as an experimental island, able to operate alone or ...

1998-12-31

483

US Department of Energy Nuclear Energy University program in robotics for advanced reactors: Program plan, FY 1987-1991  

International Nuclear Information System (INIS)

The US Department of Energy has provided support to four universities and the Oak Ridge National Laboratory in order to pursue research leading to the development and deployment of an advanced robotic system capable of performing tasks that are hazardous to humans, that generate significant occupational radiation exposure, and/or whose execution times can be reduced if performed by an automated system. The goal is to develop a generation of advanced robotic systems capable of performing surveillance, maintenance, and repair tasks in nuclear facilities and other hazardous environments. This goal will be achieved through a team effort among the Universities of Florida, Michigan, Tennessee, Texas, and the Oak Ridge National Laboratory, and their industrial partners, Combustion Engineering, Martin Marietta Baltimore Aerospace, Odetics, Remotec, and Telerobotics International. Each of the universities and ...

484

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter ...

1994-09-01

485

FFTF [Fast Flux Test Facility] Integrated Leak Rate Test Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The multiple computer ...

486

A small size continuous run industrial gamma irradiator  

Energy Technology Data Exchange (ETDEWEB)

A new small size gamma irradiator is being set up at Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Brazil, with a revolutionary design. The developed technology for this facility consists of continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m{sup 2} of floor area, the irradiator design is product overlap sources and the maximum capacity of Cobalt-60 wet sources is 37 PBq (1 MCi). The irradiator is being installed in a Governmental Institution and it will be used as a demonstration facility for manufacturers, who need an economic and logistic in-house irradiation system alternative. Also, it will be useful for supporting the local scientific ...

2004-10-01

487

A PC-based software package for modeling DOE mixed-waste management options  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (DOE) Headquarters and associated contractors have developed an IBM PC-based software package that estimates costs, schedules, and public and occupational health risks for a range of mixed-waste management options. A key application of the software package is the comparison of various waste-treatment options documented in the draft Site Treatment Plans prepared in accordance with the requirements of the Federal Facility Compliance Act of 1992. This automated Systems Analysis Methodology consists of a user interface for configuring complexwide or site-specific waste-management options; calculational algorithms for cost, schedule and risk; and user-selected graphical or tabular output of results. The mixed-waste management activities modeled in the automated Systems Analysis Methodology include waste storage, characterization, handling, transportation, treatment, and disposal. Analyses of ...

1995-02-01

488

Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated ...

2007-08-01

489

Experimental studies of 4-inch pipe whip test under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. The present paper describes the results of the pipe whip tests using test pipes of 4 inch diameter, under the BWR LOCA conditions, which were performed from 1979 to 1981. The tests were carried out at an initial pressure of about 6.8 MPa and an initial temperature of about 285/sup 0/C. The test pipe was 114.3 mm (4 in) in diameter, 8.6 mm in thickness and 4500 mm in length. The four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and frabricated from Type 304 stainless steel. The experimental parameters were the clearance (30, 50 and 100 mm) and the overhang length (250, 400, 550 and 1000 mm). The main purpose of ...

1983-10-01

490

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area either from the CRPC or will get to know the ...

2004-02-01

491

Lead recycling; Namari no recycle  

Energy Technology Data Exchange (ETDEWEB)

In Japan, lead has been widely used for gasoline additives, inorganic chemicals such as pigment, lead pipes/plates, and coating materials of cable. Because of the steady increase in car population and the mounting of environmental concern, lead consumption ratio for lead-acid batteries is tending to increase gradually up to 70% with decreasing the consumption for gasoline additives. This paper describes the recycling of lead-acid batteries in Japan. Since the latter half of FY 1994, the battery manufacturing industry started the new lead recycling system. The recycling ratio of the used lead-acid batteries became 90% in 1996 from 84% in 1994. In near future, it can reach to 95%, the recycling ratio in some European countries. The primary smelting occupies 53%, and the secondary smelting occupies 47%. For the conventional method by secondary smelting makers, reduction smelting and copper removing of lead electrodes are conducted, and lead is ...

1997-12-25

492

Extracting energy from hydraulically-fractured geothermal reservoirs  

Science.gov (United States)

The governing equations for heat and mass transfer were derived for hydraulically fractured geothermal reservoirs. When converted to nondimensional form it was shown that the equations can be considerably simplified. The resulting equations can be strongly influenced by the effects of buoyancy; the magnitude of the effect is measured by the ratio of the Grashof and Reynolds numbers, and the ratio of the actual permeability of the fracture and the square of the fracture gap width. Significant quantities of energy can be extracted from hydraulic fractures--even without thermal stress fracturing. The amount is limited by the size of the fracture and the low thermal conductivity of rock. The viscous pressure drop in open fractures is insignificant, and depending upon losses in piping and surface equipment, the entire system could be ''self-pumped'' due to buoyancy. Thermal contraction of the rock tends to ...

1976-01-01

493

Applications of cathodic protection for the protection of aqueous and soil corrosion of power plant components  

International Nuclear Information System (INIS)

Power plant components exposed to environments such as water and soil are susceptible to severe corrosion. Many times the effect of corrosion in power plant components can be catastrophic. The problem is aggravated for underground pipelines due to additional factors such as large network of pipelines, proximity to earth mat, high voltage transmission lines, corrosive chemicals, inadequate approach etc. Other components such as condenser water boxes, internals of pipelines, clarifier bridge structures, cooling water inlet gates and pipes etc. which are in continuous contact with water, are subjected to severe corrosion. The nature and locations of all such components are at places which are not accessible for routine maintenance and hence they require long term reliable protection against corrosion. Experience has shown that anti-corrosive coatings are inadequate in preventing corrosion and due to their location regular maintenance coatings are also not feasible. ...

1999-11-22

494

An Experimental study on a Method of Computing Minimum flow rate  

International Nuclear Information System (INIS)

Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for the pump manufacturer' proprietary. The objective of this study is to obtain experimental data for ...

2009-10-01