Energy Technology Data Exchange (ETDEWEB)
A performance assessment of the operating Solid Waste Storage Area 6 (SWSA 6) facility for the disposal of low-level radioactive waste at the Oak Ridge National Laboratory has been prepared to provide the technical basis for demonstrating compliance with the performance objectives of DOE Order 5820.2A, Chapter 111.2 An analysis of the uncertainty incorporated into the assessment was performed which addressed the quantitative uncertainty in the data used by the models, the subjective uncertainty associated with the models used for assessing performance of the disposal facility and site, and the uncertainty in the models used for estimating dose and human exposure. The results of the uncertainty analysis were used to interpret results and to formulate conclusions about the ...
1994-12-31
High level waste storage tanks 242-A evaporator S/RID phase II assessment report
Energy Technology Data Exchange (ETDEWEB)
This document, the Standards/Requirements Identification Document (S/RID) Phase 2 Assessment Report for the subject facility, represents the results of a Performance Assessment to determine whether procedures containing S/RID requirements are fully implemented by field personnel in the field. It contains a summary report and three attachments; an assessment schedule, performance objectives, and assessments for selected functional areas.
1996-09-27
Energy Technology Data Exchange (ETDEWEB)
A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.
1981-08-07
Radiological performance assessment for the E-Area Vaults Disposal Facility
Energy Technology Data Exchange (ETDEWEB)
This report is the first revision to ``Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0.
2000-04-11
Assessing predictive skill of models to optimise crop management and design
Environmental Research Database
DescriptionAn ability to foresee impacts on output is invaluable to any industry; good prediction is the basis of good management. Many research models can predict crop performance, but the skill (used here to include accuracy, precision, facility and credibility) of these predictions is rarely assessed, so is not well known. The only research model successfully adopted for practical purposes in the UK is the Broom's Barn Beet Model. Thus we propose here, research to assess and publish the skill of the [continued...
2004-01-30
Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...
1996-01-01
Energy Technology Data Exchange (ETDEWEB)
Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code's ability to represent the main phenomena of experiments in both cases was satisfactory.
1992-04-01
Energy Technology Data Exchange (ETDEWEB)
Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code`s ability to represent the main phenomena of experiments in both cases was satisfactory.
1992-04-01
International Nuclear Information System (INIS)
Natural circulation experiments carried out in the REWET-III facility in 1985 have been used for RELAP5/MOD2 assessment. The REWET-III facility is a scaled-down model of VVER-440 type reactors. The facility consists of a pressure vessel in which the downcomer is simulated with an external pipe assembly, hot and cold legs with loop seals and a horizontal steam generator. The volume scaling factor compared to the reference reactor is 1:2333. The present paper summarizes the experiences gained in the RELAP5/MOD2 calculations of selected REWET-III single- and two-phase natural circulation experiments. The code's ability to represent the main phenomena of experiments in both cases was satisfactory.
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site disposes of low-level radioactive waste within on-site engineered disposal facilities. The Savannah River Site must demonstrate that these disposals meet the requirements of DOE Order 435 . 1 through a process known as performance assessment (PA). The objective of this document is to provide the radionuclide -specific data needed for the PA calculations . This work is part of an on-going program to periodically review and update existing PA work as new data becomes available. Revision of the E -Area Low-Level Waste Facility PA is currently underway. The number of radionuclides selected to undergo detailed analysis in the PA is determined by a screening process. The basis of this process is described. Radionuclide-specific data for half-lives, decay modes, daughters, dose conversion factors and groundwater concentration limits are presented with source references and ...
2007-03-20
This report assesses the water quality related benefits that would be expected if the US Environmental Protection Agency (EPA) adopts the proposed effluent limitations, guidelines and pretreatment standards for the Centralized Waste Treatment (CWT) Industry. EPA estimates that under baseline conditions 205 CWT facilities discharge approximately 5.22 million lbs/year of metal and organic pollutants.
1998-12-01
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
Tiger Team assessment of the Brookhaven National Laboratory
Energy Technology Data Exchange (ETDEWEB)
This report documents the results of the Department of Energy's (DOE's) Tiger Team Assessment conducted at Brookhaven National Laboratory (BNL) in Upton, New York, between March 26 and April 27, 1990. The BNL is a multiprogram laboratory operated by the Associated Universities, Inc., (AUI) for DOE. The purpose of the assessment was to provide the status of environment, safety, and health (ES H) programs at the laboratory. The scope of the assessment included a review of management systems and operating procedures and records; observations of facility operations; and interviews at the facilities. Subteams in four areas performed the review: ES H, Occupational Safety and Health, and Management and Organization. The assessment was comprehensive, covering all areas of ES H activities and waste management operations. Compliance ...
1990-06-01
Assessment of radiological safety of Wolsung site at site boundary considering crack impact
British Library Electronic Table of Contents (United Kingdom)
The number of spent fuel storage facilities in the world continues to increase because of "Wait and See" policies and delay of a permanent disposal plan. The temporary spent fuel storage concept is changing to a pre-disposal storage concept. Strengthened safety concepts are required for expanded spent fuel storage facilities and sites. The Korea Hydro and Nuclear Power Company is planning to construct a reinforced concrete MACSTOR-400 facility at Wolsung. In concrete dry spent fuel storage structures, cracks can occur due to radiant heat and environmental chloride. The likelihood of cracking increases over time. Research on changes in shielding performance from one collinear crack in the surface of a concrete facility has been carried out. However there is no research about public radiolog...
2010-01-01
Performance Assessment of Physical Protection System at Wolsong Nuclear Power Plant using SAVI code
Energy Technology Data Exchange (ETDEWEB)
The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several techniques are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsong NPP using SAVI code. The first is that the SAVI constructs the site-specific Adversary Sequence Diagram (ASD) of the PPS. This ...
2005-07-01
Reference equilibrium core with central flux irradiation facility for Pakistan research reactor-1
International Nuclear Information System (INIS)
In order to assess various core parameters a reference equilibrium core with Low Enriched Uranium (LEU) fuel for Pakistan Research Reactor (PARR-1) was assembled. Due to increased volume of reference core, the average neutron flux reduced as compared to the first higher power operation. To get a higher neutron flux an irradiation facility was created in centre of the reference equilibrium core where the advantage of the neutron flux peaking was taken. Various low power experiments were performed in order to evaluate control rods worth and neutron flux mapping inside the core. The neutron flux inside the central irradiation facility almost doubled. With this arrangement reactor operation time was cut down from 72 hours to 48 hours for the production of the required specific radioactivity. (author)
2008-07-01
Waste sampling and characterization facility (WSCF) maintenance implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP) is written to satisfy the requirements of the US Department of Energy (DOE) Order 4330.4B, Maintenance Management Program that specifies the general policy and objectives for the establishment of the DOE controlled maintenance programs. These programs provide for the management and performance of cost effective maintenance and repair of the DOE property, which includes facilities. This document outlines maintenance activities associated with the facilities operated by Waste Management Hanford, Inc. (WMH). The objective of this MIP is to provide baseline information for the control and execution of WMH Facility Maintenance activities relative to the requirements of Order 4330.4B, assessment of the WMH maintenance programs, and actions necessary to maintain compliance with the Order. Section 2.0 summarizes the history, mission and description ...
1997-08-13
Operational procedures - industry observations and opportunities for improvement
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to relate some of the commonly encountered problems with operational procedures in the nuclear industry and offer practical suggestions for their elimination. The paper is based on recent consultant experience in assisting industry clients with human performance related design and assessment initiatives. Operational procedures are a key part of an integrated system design. Procedures provide the specified instructions for actions people are to undertake in operating a facility to achieve production and safety goals. While organizations continue to make substantial investments in procedure development and maintenance, problems with procedures continue to occur, as evidenced through operating inefficiencies, errors, and events. The paper reviews the role procedures play in facility operations, comments on current development and maintenance practices, discusses the extent of ...
2003-07-01
Photovoltaic industry manufacturing technology. Final report
Energy Technology Data Exchange (ETDEWEB)
This report contains the results of the Photovoltaic (PV) Industry Manufacturing Technology Assessment performed by the Automation and Robotics Research Institute (ARRI) of the University of Texas at Arlington for the National Renewable Energy laboratory. ARRI surveyed eleven companies to determine their state-of-manufacturing in the areas of engineering design, operations management, manufacturing technology, equipment maintenance, quality management, and plant conditions. Interviews with company personnel and plant tours at each of the facilities were conducted and the information compiled. The report is divided into two main segments. The first part of the report presents how the industry as a whole conforms to ``World Class`` manufacturing practices. Conclusions are drawn from the results of a survey as to the areas that the PV industry can improve on to become more competitive in the industry and World Class. Appendix ...
1998-08-01
The Application of Simulation Methods to Intra-Airport ...
... Descriptors : *Terminal flight facilities, *Traffic ... Ground support, Queueing theory, Passengers ... Delay, Assessment, Stochastic processes, Ground ...
1975-09-01
Maintenance Implementation Plan for solid waste
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP) has been developed for. implementation of the US Department of Energy (DOE) Order 4330.4A. Maintenance Implementation Program (DOE 1990) at the Hanford Site Solid Waste complex. It addresses maintenance functions associated with Solid Waste Management, which includes the field operational group and the facilities operational group. An assessment of the existing maintenance programs for Solid Waste was performed, and the results of this assessment were evaluated to determine corrective actions required to bring Solid Waste Maintenance into compliance with the order. The MIP assessment disclosed that most elements defined in the order are currently implemented for Solid Waste. It also identified issues which must be addressed to bring the maintenance function into full compliance with DOE Order 4330.4A. These include documentation of the ...
1992-06-01
RELAP5/MOD3.1 and APROS 3.0 analyses of SBLOCA in scaled VVER-440 geometry
Energy Technology Data Exchange (ETDEWEB)
A cold-leg small-break loss-of-coolant accident (SBLOCA) experiment was performed on the PACTEL facility to study the behavior of natural circulation in a VVER-440 reactor geometry. The facility is a volumetrically scaled (1:305) integral test loop simulating the VVER-440 reactors used in Finland. The test results were used to assess the computer codes RELAP5/MOD3.1 and APROS 3.0 for VVER reactors. The behavior of the horizontal steam generator and the effect of the hot-leg loop seal were of particular interest. The specific parameters to be compared included the primary pressure and the downcomer mass flow rate.
1995-12-31
RELAP5/MOD3.1 and APROS 3.0 analyses of SBLOCA in scaled VVER-440 geometry
International Nuclear Information System (INIS)
A cold-leg small-break loss-of-coolant accident (SBLOCA) experiment was performed on the PACTEL facility to study the behavior of natural circulation in a VVER-440 reactor geometry. The facility is a volumetrically scaled (1:305) integral test loop simulating the VVER-440 reactors used in Finland. The test results were used to assess the computer codes RELAP5/MOD3.1 and APROS 3.0 for VVER reactors. The behavior of the horizontal steam generator and the effect of the hot-leg loop seal were of particular interest. The specific parameters to be compared included the primary pressure and the downcomer mass flow rate.
1995-11-01
Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand ...
2006-07-01
Vulnerability Analysis of Physical Protection System at Wolsung Nuclear Power Plant
International Nuclear Information System (INIS)
The 9/11 event in the U.S.A has increased international terror possibilities against nuclear facilities including nuclear power plants(NPPs). It is necessary to assess the performance of an existing physical protection system(PPS) at nuclear facilities based on such malevolent acts. A PPS is a complex configuration of detection, delay, and response elements. Several methods are available to analyze a PPS and evaluate its effectiveness. Sandia National Laboratory(SNL) in the USA was developed a System Analysis of Vulnerability to Intrusion (SAVI) computer code for this purpose. It is powerful software for evaluating the effectiveness of PPS against outsider threats. This study presents the performance assessment of the PPS at Wolsung NPP using SAVI code. First, the site-specific Adversary Sequence Diagrams(ASDs) of the PPS is constructed. It helps to understand ...
2006-05-25
Fast Flux Test Facility performance monitoring management information, April 1988
Energy Technology Data Exchange (ETDEWEB)
The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators.
1988-05-01
Utilization of low rank coals in liquefaction
Energy Technology Data Exchange (ETDEWEB)
The objective of the current MITRE study is to estimate the cost of the coal derived liquid products that result from processing low rank coals in the Wilsonville and HRI CTSL configurations. The resultant cost of liquids is then compared to liquids produced from bituminous coals. The methodology used to accomplish the above objective was to utilize the MITRE coal liquefaction cost model to assess the overall technical and economic performance of low rank coals in both the Wilsonville and HRI configurations. Actual test data from Wilsonville and HRI was used as the basis for these analyses. This test data is modified to simulate complete resid recycle extinction and to standardize the operating performance of the deashing unit. This corrected yield data is then used in the simulation models to predict the overall performance and economics of a conceptual commercial coal liquefaction ...
1991-01-01
Boil-off experiments with the EIR-NEPTUN Facility: Analysis and code assessment overview report
International Nuclear Information System (INIS)
The NEPTUN data discussed in this report are from core uncovery (boil-off) experiments designed to investigate the mixture level decrease and the heat up of the fuel rod simulators above the mixture level for conditions simulating core boil-off for a nuclear reactor under small break loss-of-coolant accident conditions. The first series of experiments performed in the NEPTUN test facility consisted of ten boil-off (uncovery) and one adiabatic heat-up tests. In these tests three parameters were varied: rod power, system pressure and initial coolant subcooling. The NEPTUN experiments showed that the external surface thermocouples do not cause a significant cooling influence in the rods to which they are attached under boil-off conditions. The reflooding tests performed later on indicated that the external surface thermocouples have some effect during reflooding for NEPTUN electrically heated rod bundle. Peak cladding ...
Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment
Energy Technology Data Exchange (ETDEWEB)
Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance ...
1999-09-09
International Nuclear Information System (INIS)
The paper discusses the safety problems connected with the conversion to dense storage of RBMK-1000 spent fuel in reactor cooling pools and independent storage facilities. Recourse to dense storage has been made for a number of reasons, among which are the absence of spent fuel shipments from the nuclear power plant site, prolongation of storage time and a partial change in storage conditions. Increasing the storage density per unit volume of the storage facility and turning to new technical procedures (as against the basic design) call for further investigation of safety problems. The safety assessment of the dense storage mode includes: (1) Selecting a list of initiating events for design basis and unforeseeable accidents; (2) Assessing dense storage safety under normal as well as design basis accident conditions; (3) Safety analysis and development of measures to compensate for unforeseen accidents. ...
1995-08-01
Space reactor fuel element testing in upgraded TREAT
Energy Technology Data Exchange (ETDEWEB)
The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc., a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR), NERVA-derivative, and other concepts. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. initial results suggest that full-scale PBR, elements could be tested at an average energy deposition of {approximately}60--80 MW-s/L in the current TREAT reactor. If the TREAT reactor was upgraded to include fuel elements with a higher temperature limit, average energy deposition of {approximately}100 MW/L may be achievable.
1993-05-01
Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B
International Nuclear Information System (INIS)
Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of ...
A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit
Energy Technology Data Exchange (ETDEWEB)
In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.
1996-08-01
Performance assessment for the disposal of low-level waste in the 200 east area burial grounds
Energy Technology Data Exchange (ETDEWEB)
A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of ...
1996-08-15
Decommissioning of facility for use of radioisotopes on waste management and disposal facility
Energy Technology Data Exchange (ETDEWEB)
All the tests have been finished up in the Waste Management and Disposal Facility which has been used for the safety tests of solidified radioactive waste on sea dumping disposal. The decommissioning of this facility was performed for use of radioisotopes. This report describes the plan on decommissioning of facility for use of radioisotopes, the contamination checking methods and measurement of radioactivity, the fore case and practice for amount of generated radioactive wastes, the operation procedures for dismantlement, the safety measures, the expenses for decommissioning and so on. (author)
1999-09-01
Energy Technology Data Exchange (ETDEWEB)
Atomic Energy of Canada has recently submitted for regulatory and public review an Environmental Impact Statement (EIS) on a concept for disposal of Canada`s nuclear fuel waste. The EIS is supported by nine primary references that summarize major aspects of the concept, including a postclosure environmental and safety assessment. The scope of the postclosure assessment is largely determined by the requirements of the Atomic Energy Control Board (AECB) of Canada. These requirements include a quantitative estimate of the annual effective dose equivalent to an individual in the most exposed group of people (the critical group) for 10,000 years following closure of the disposal facility, and a radiological risk criterion with an associated dose rate limit of 0.05 mSv/a. Over this long time frame, a quantitative assessment cannot be based on actual observations, and thus we use scientific arguments and ...
1995-12-01
Energy Technology Data Exchange (ETDEWEB)
Low and intermediate waste disposal facilities safety assessment is comprised of several steps from site selection , construction and operation to post-closure performance assessment. This is a multidisciplinary and complex task , and can not be analyzed by one expert only. This high complexity can lead to ambiguity and vagueness in information and consequently in the decision making process. In order to make the decision process clear and objective, there is the need to provide the decision makers with a clear and comprehensive picture of the whole process and, at the same time, simple and easily understandable by the public. This paper suggests the development of an inference system based on fuzzy decision making methodology. Fuzzy logic tools are specially suited to deal with ambiguous data by using language expressions. This process would be capable of integrating knowledge from various fields of ...
2002-07-01
British Library Electronic Table of Contents (United Kingdom)
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
2007-01-01
Fuel management at the Petten high flux reactor
Energy Technology Data Exchange (ETDEWEB)
Several years ago the shipment of spent fuel of the High Flux Reactor (HFR) at Petten has come to a standstill resulting in an ever growing stock of fuel elements that are labelled 'fully burnt up'. Examination of those elements showed that a reasonably number of them have a relatively high {sup 235}U mass left. A reactor physics analysis showed that the use of such elements in the peripheral core zone allows the loading of four instead of five fresh fuel elements in many cycle cores. For the assessment of safety and performance parameters of HFR cores a new calculational tool is being developed. It is based on AEA Technology's Reactor physics code suite Winfrith Improved Multigroup Scheme (WIMS). NRG produced pre- and post-processing facilities to feed input data into WIMS's 2D transport code CACTUS and to extract relevant parameters from the output. The processing ...
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
A numerical model of multiphase air-water flow and contaminant transport in the unsaturated zone is presented. The multiphase flow equations are solved using the two-pressure, mixed form of the equations with a modified Picard linearization of the equations and a finite element spatial approximation. A volatile contaminant is assumed to be transported in either phase, or in both phases simultaneously. The contaminant partitions between phases with an equilibrium distribution given by Henry`s Law or via kinetic mass transfer. The transport equations are solved using a Galerkin finite element method with reduced integration to lump the resultant matrices. The numerical model is applied to published experimental studies to examine the behavior of the air phase and associated contaminant movement under water infiltration. The model is also used to evaluate a hypothetical design for a low-level radioactive waste disposal facility. The model has been developed in both ...
1995-05-01
International Nuclear Information System (INIS)
The High Flux Isotope Reactor (HFIR) located at Oak Ridge National Laboratory is one of the world's most powerful research reactors. In 1996, one year after the demise of the Advanced Neutron Source Project, the U.S. Department of Energy embarked on an aggressive program to upgrade the neutron scattering facilities at the HFIR. These upgrades, which are now in progress, include the installation of larger beam tubes, a high-performance hydrogen cold source, and additional neutron guides and neutron scattering instruments. An extensive analysis effort was performed over the past 4 yr to support the design of the modified beamlines and new user facilities and to assess the impact of the upgrades on the integrity of the existing reactor system. The results of three of these analyses are summarized here. Specifically, results are presented for analyses related to the design of the new ...
2001-06-17
Materials considerations for the National Spallation Neutron Source target
Energy Technology Data Exchange (ETDEWEB)
The National Spallation Neutron Source (NSNS), in which neutrons are generated by bombarding a liquid mercury target with 1 GeV protons, will place extraordinary demands on materials performance. The target structural material will operate in an aggressive environment, subject to intense fluxes of high energy protons, neutrons, and other particles, while exposed to liquid mercury and to water. Components that require special consideration include the Hg liquid target container and protective shroud, beam windows, support structures, moderator containers, and beam tubes. In response to these demands a materials R and D program has been developed for the NSNS that includes: selection of materials; calculations of radiation damage; irradiations, post irradiation testing, and characterization; compatibility testing and characterization; design and implementation of a plan for monitoring of materials performance in service; and materials engineering ...
1997-08-01
FY 1987 current fiscal year work plan
Energy Technology Data Exchange (ETDEWEB)
This Current Year Work Plan presents a detailed description of the activities to be performed by the Joint Integration Office during FY87. It breaks down the activities into two major work areas: Program Management and Program Analysis. Program Management is performed by the JIO by providing technical planning and guidance for the development of advanced TRU waste management capabilities. This includes equipment/facility design, engineering, construction, and operations. These functions are integrated to allow transition from interim storage to final disposition. JIO tasks include program requirements identification, long-range technical planning, budget development, program planning document preparation, task guidance, task monitoring, information gathering and task reporting to DOE, interfacing with other agencies and DOE lead programs, integrating public involvement with program efforts, and preparation of program status ...
1986-12-01
Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for low-level and mixed low-level wastes has been restricted to lined ...
2006-03-30
Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev
International Nuclear Information System (INIS)
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
2003-02-01
Hazardous waste treatment and environmental remediation research
Energy Technology Data Exchange (ETDEWEB)
Los Alamos National Laboratory (LANL) is currently evaluating hazardous waste treatment and environmental remediation technologies in existence and under development to determine applicability to remediation needs of the DOE facilities under the Albuquerque Operations Office and to determine areas of research need. To assist LANL is this effort, Science Applications International Corporation (SAIC) conducted an assessment of technologies and monitoring methods that have been demonstrated or are under development. The focus of this assessment is to: (1) identify existing technologies for hazardous waste treatment and environmental remediation of old waste sites; (2) identify technologies under development and the status of the technology; (3) assess new technologies that need development to provide adequate hazardous waste treatment and remedial action technologies for DOD and DOE sites; and (4) identify ...
1989-09-29
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Georgia Army National Guard (GAARNG) facility near Hinesville, Georgia, known as the National Guard Training Center (NGTC). Preliminary assessments of federal facilities are being conducted to compile the information necessary for completing preremedial activities and to provide a priority basis for completing corrective actions (where necessary) in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining previous site activities, types and quantities of hazardous substances utilized, and potential pathways by which contamination could affect public health and the environment. The scope of this assessment is limited to the facilities ...
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
This Site Maintenance Plan has been developed for Pacific Northwest Laboratory's (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; ...
1992-09-28
Energy Technology Data Exchange (ETDEWEB)
This Site Maintenance Plan has been developed for Pacific Northwest Laboratory`s (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; Maintenance ...
1992-09-28
UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples
Energy Technology Data Exchange (ETDEWEB)
The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve ...
2000-06-12
Sintered Reaction Bonded Silicon Parts by Microwave Nitridation Combined with Gas-Pressure Sintering
Energy Technology Data Exchange (ETDEWEB)
The cooperative project was a joint development program between Ceradyne and Oak Ridge National Laboratory through Lockheed Martin Energy Research (LMER). Cooperative work was of benefit to both parties. ORNL was able to assess the effect of the microwave nitridation process coupled with gas-pressure sintering for fabrication of parts for advanced diesel engines. Ceradyne gained access to gelcasting expertise and microwave facilities and experience for the nitridation of SRBSN materials. The broad objective of the CRADA between Ceradyne and OIWL was to (1) examine the applicability of the gelcasting technology to fabricate parts from SRBSN, and (2) to assess the effect of the microwave nitridation of silicon process coupled with gas-pressure sintering for fabrication of parts for advanced diesel engines. The following conclusions can be made from the work performed under the CRADA: (1) Gelcasting is a ...
1999-01-01
International Nuclear Information System (INIS)
There has been recent interest in the United States concerning the loss of residual heat removal system (RHRS) under reduced coolant inventory conditions for pressurized water reactors. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-III experimental facility at Siemens-KWU to supply applicable data. Recently, an NRC-sponsored effort has been undertaken at the Idaho National Engineering Laboratory to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following the long term loss-of-RHRS during reduced inventory operation. The thermal-hydraulic response of a closed reactor coolant system during such a transient is investigated in this report. Some of the specific processes investigated include: reflux condensation in the steam generators, the corresponding pressure increase in the reactor coolant system, and void fraction distributions ...
1992-04-01
International Nuclear Information System (INIS)
Treatment chemicals are used in all facets of the natural gas industry (NGI) from well development through transmission and storage of natural gas. The multitude of chemicals used, combined with the dozens of chemical manufacturers and/or suppliers has lead to the availability of hundreds of possible chemical products. Because of the widespread use of chemical products and their numerous sources, the NGI needs access to consistent data regarding their effectiveness and potential environmental impacts. The objective of this work was to evaluate the effectiveness and potential environmental impacts of, chemical products used in the NGI. This assessment was initially focused on biocides and corrosion inhibitors and their use in the gas production, storage and transmission facilities, The overall approach was obtain the necessary data on chemical use and effectiveness directly from the oil and gas industry, supplemented with data/information ...
1995-03-27
Energy Technology Data Exchange (ETDEWEB)
As part of the work scope set in the French law on high level long lived waste R&D passed in 1991, CEA is conducting a research program to establish the scientific basis and assess the feasibility of long term storage as an option for the safe management of nuclear waste for periods as long as centuries. This goal is a significant departure from the current industrial practice where storage facilities are usually built to last only a few decades. From a technical viewpoint such an extension in time seems feasible provided care and maintenance is exercised. Considering such long periods of time, the risk for Society of loosing oversight and control of such a facility is real, which triggers the question of whether and how long term storage safety can be actually achieved. Therefore CEA commissioned a study (1) in which MUTADIS Consultants (2) and CEPN (3) were both involved. The case study looks into several past and ...
2003-02-24
Analysis of a Fast Spectrum Irradiation Facility in the High Flux Isotope Reactor
Energy Technology Data Exchange (ETDEWEB)
The Global Nuclear Energy Partnership (GNEP) is proposing to develop a sodium-cooled fast-spectrum reactor (SFR) to transmute and consume actinides from discharged nuclear fuel. To meet performance objectives, new and advanced fuels and targets need to be developed. The fuels to be irradiated include metal and oxide mixed actinides (U-Np-Pu-Am-Cm); for the target concept, Am-Cm has been considered. A significant part of the development process is the irradiation of the fuel and cladding in a prototypic fast reactor environment to determine the performance under irradiation. Analysis results are presented in this paper for a fast-neutron irradiation facility design based on the large fast neutron flux available in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) combined with the use of a strongly-absorbing thermal neutron shield. Several designs were assessed; the preferred ...
2008-09-01
DOE reports on feasibility of generic oil shale test facility
Energy Technology Data Exchange (ETDEWEB)
In order to assess whether an oil shale test facility would be of significant use to private sector oil shale developers, the US DOE has studied the past history of oil shale development and its potential for replacing petroleum supplies. A generic test facility's primary function would be to test concepts of mining, retorting, upgrading, and environmental aspects at the engineering scale. This paper summarizes the US oil shale resources, gives a technology analysis, and discusses the potential for a test facility.
1987-03-01
ESBWR related passive decay heat removal tests in PANDA
International Nuclear Information System (INIS)
A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated and the effect of light ...
1999-04-19
Energy Technology Data Exchange (ETDEWEB)
This document, the Standards/Requirements Identification Document (S/RID) Phase I Assessment Report for the subject facility, represents the results of an Administrative Assessment to determine whether S/RID requirements are fully addressed by existing policies, plans or procedures. It contains; compliance status, remedial actions, and an implementing manuals report linking S/RID elements to requirement source to implementing manual and section.
1996-09-30
Advanced Simulation and Computing FY10-FY11 Implementation Plan Volume 2, Rev. 0.5
Energy Technology Data Exchange (ETDEWEB)
The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the surety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with current and future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering (D&E) programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing Program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile ...
2009-09-08
Advanced Simulation & Computing FY09-FY10 Implementation Plan Volume 2, Rev. 0
Energy Technology Data Exchange (ETDEWEB)
The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the safety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with current and future nonnuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing Program (ASC)1 is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile ...
2008-04-30
Assessment of the PIUS physics and thermal-hydraulic experimental data bases
Energy Technology Data Exchange (ETDEWEB)
The PIUS reactor utilizes simplified, inherent, passive, or other innovative means to accomplish safety functions. Accordingly, the PIUS reactor is subject to the requirements of 10CFR52.47(b)(2)(i)(A). This regulation requires that the applicant adequately demonstrate the performance of each safety feature, interdependent effects among the safety features, and a sufficient data base on the safety features of the design to assess the analytical tools used for safety analysis. Los Alamos has assessed the quality and completeness of the existing and planned data bases used by Asea Brown Boveri to validate its safety analysis codes and other relevant data bases. Only a limited data base of separate effect and integral tests exist at present. This data base is not adequate to fulfill the requirements of 10CFR52.47(b)(2)(i)(A). Asea Brown Boveri has stated that it plans to conduct more separate effect and integral test programs. ...
1993-12-31
UK PubMed Central (United Kingdom)
ObjectiveThis study assessed the relationship between multiple indicators of ‘real-world’ functioning and scores on a brief performance-based measure...Full Text Available
2010-02-01
PRA QUALITY IN REGULATORY DECISIONS
ASME PRA STANDARD FOR PRA. FOR NPP APPLICATION. " Provides a Standard for performing and using a. PRA. Definitions. Risk assessment ...
Psychological Resilience and Neurocognitive Performance in a Traumatized Community Sample
UK PubMed Central (United Kingdom)
BackgroundWhether psychological resilience correlates with neurocognitive performance is largely unknown. Therefore, we assessed association between neurocognitive...Full Text Available
2010-08-01
Maintenance implementation plan for solid waste management
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation Plan (MIP)was developed for implementation of the U.S. Department of Energy (DOE) Order 4330.4A, A Maintenance Implementation Program (DOE 1990) which has been replaced by 4330.4B (DOE 1994) at the Hanford Site SWM complex. It addresses maintenance functions associated with SWM, which includes the field operational group and the facilities operational group. An assessment of the existing maintenance programs for SWM was performed, and the results of this assessment were evaluated to determine corrective actions required to bring Solid Waste Maintenance into compliance with the order. The objective of this MIP is to provide baseline information for the control and execution of SWM Maintenance activities relative to the requirements of Order 4330.4B, Chapter II. (Nuclear Facilities) It also describes actions that are planned to achieve compliance. ...
1996-06-27
Assessment of gas flammability in transuranic waste container
Energy Technology Data Exchange (ETDEWEB)
The Safety Analysis Report for the TRUPACT-II Shipping Package [Transuranic Package Transporter-II (TRUPACT-II) SARP] set limits for gas generation rates, wattage limits, and flammable volatile organic compound (VOC) concentrations in transuranic (TRU) waste containers that would be shipped to the Waste Isolation Pilot Plant (WIPP). Based on existing headspace gas data for drums stored at the Idaho National Engineering Laboratory (INEL) and the Rocky Flats Environmental Technology Site (RFETS), over 30 percent of the contact-handled TRU waste drums contain flammable VOC concentrations greater than the limit. Additional requirements may be imposed for emplacement of waste in the WIPP facility. The conditional no-migration determination (NMD) for the test phase of the facility required that flame tests be performed if significant levels of flammable VOCs were present in TRU waste containers. This paper describes an approach ...
1995-12-01
International Nuclear Information System (INIS)
To be able to carry out review functions regulatory authorities must be able to make critical evaluations of proponent's safety cases. In Sweden the Swedish Radiation Safety Authority aims to have in place its own suite of performance assessment tools. This paper looks at the role and application of a regulator's models to important features of current modelling in a proponent's performance assessment. (authors)
Effectively managing nuclear risk through human performance improvement
International Nuclear Information System (INIS)
Full text: The US commercial nuclear industry has just completed an outstanding decade of plant performance. Safety levels and electric production are at unprecedented high levels and continue to exceed even high industry goals. Nuclear energy continues to keep the highest priority on performance improvement programs and highly trained/qualified people that maintain its record setting safety and reliability of operations. While the industry has maintained a consistently high level of performance, the advent of deregulation and the consolidation of NPP ownership, as well as the current climate of concern about both rising energy costs and availability of power, has raised the standard for nuclear energy's level of competitiveness in today's market place. The resulting challenge is how to more effectively manage risk and improve performance even further in a generally high performing ...
Current status of siting a new near surface repository in Romania
International Nuclear Information System (INIS)
Full text: The site selection process for a near surface repository dedicated for the radioactive waste resulted from the Cernavoda NPP operation and decommissioning started early in 90's. Each site selection stage included the collection of data from specific field and laboratory works as well as the appropriate safety performance evaluation. In order to assess/confirm the performance of the natural barrier of the Saligny site, the radionuclide concentration in the disposal system compartments has been evaluated, as complementary safety indicator of repository. The siting process was made in accordance with national and international regulations and standards and using a conceptual design similar to those used at L'Aube (France), ElCabril (Spain) or Mohovce (Slovak Republic). ANDRAD, the Romanian waste management organization that has continued the siting process in the last three years applied and obtained a partial ...
2009-05-27
Verification of the CFD code FLUENT by post test calculation of ROCOM experiments
International Nuclear Information System (INIS)
Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged ...
2005-10-02
Fast Flux Test Facility Reactor Vessel Removal Study
Energy Technology Data Exchange (ETDEWEB)
This study assesses the feasibility of removing the FFTF reactor vessel from its current location in the reactor cavity inside the Containment vessel to a transporter for relocation to a burial pit in the 200 Area.
2002-10-23
An old tool with potential new uses: return on investment
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to examine potential new uses of return on investment (ROI) in alternative methods for library assessment and valuation. Design/methodology/approach - Uses examples of recent uses of ROI by libraries to identify potential new applications of ROI in library assessment and valuation. Findings - ROI investment has historically been used by libraries for the assessment of past performance of library organizations in a reactive/defensive nature or for assessing the value of customer services. ROI has not been widely used as a proactive assessment tool, to introspectively assess administrative or other internal services, or as an offensive assessment and valuation tool, especially for intangible performance assessment and valuation. ...
2007-01-01
Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant
International Nuclear Information System (INIS)
This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was ...
1987-01-01
Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work ...
1987-09-01
Radionuclide buildup in FFTF [Fast Flux Test Facility] heat transport system cells
International Nuclear Information System (INIS)
The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.
1989-11-26
International Nuclear Information System (INIS)
The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).
1986-01-01
International Nuclear Information System (INIS)
The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).
1986-01-01
Pathway analysis for alternate low-level waste disposal methods
International Nuclear Information System (INIS)
The purpose of this paper is to evaluate a complete set of environmental pathways for disposal options and conditions that the Nuclear Regulatory Commission (NRC) may analyze for a low-level radioactive waste (LLW) license application. The regulations pertaining In the past, shallow-land burial has been used for the disposal of low-level radioactive waste. However, with the advent of the State Compact system of LLW disposal, many alternative technologies may be used. The alternative LLW disposal facilities include below- ground vault, tumulus, above-ground vault, shaft, and mine disposal This paper will form the foundation of an update of the previously developed Sandia National Laboratories (SNL)/NRC LLW performance assessment methodology. Based on the pathway assessment for alternative disposal methods, a determination will be made about whether the current methodology can satisfactorily analyze the ...
1992-03-01
The PANDA facility and first test results
International Nuclear Information System (INIS)
The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport ...
{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins
Energy Technology Data Exchange (ETDEWEB)
Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray ...
1996-08-01
Utility applications program. Annual report for 1981
Energy Technology Data Exchange (ETDEWEB)
The purpose of the Utility Applications Program is to provide information and assistance to interested utilities on central station energy storage systems. Compressed air and underground pumped hydroelectric energy storage are the primary technical focus. Smaller utilities are the primary targets of this program, as they may not have resources to track and utilize new energy conservation developments. The program, initiated during this year-long period, consists of a series of tasks integrating and supporting energy storage implementation. Program management and technical coordination activities monitor the wide range of research ongoing both under government support and in industry and provide a locus for dissemination of results. Recently completed DOE demonstration studies provide the central data base and the DOE CAES and UPH Technology Program activities provide another major resource. In addition a UPH preliminary feasibility study in coorination with Central Vermont Public ...
1982-06-01
The control of radioactive wastes and the quality assurance requirements
International Nuclear Information System (INIS)
For prolonged storage and eventual disposal radioactive wastes will be solidified to reduce the problems which accompany liquid waste whilst solid wastes will be encapsulated in an immobilising matrix. In the solidification and encapsulation process it will be important to produce a material in a form which is chemically stable, mechanically strong and which will not react with or allow free passage of groundwater. To this end a continuous check will be required to ensure that the various wastes are chemically compatible with the solidifying and binding matrices and that the associated processes are performed against a strict Quality Programme. The Quality Programme will be extensive requiring the specification of procedures for assessing the quality and nature of the wastes, the detailed operation of the solidification and/or encapsulation, the overpack requirements for transportation and the routines to be adopted with respect to storage or ...
Energy Technology Data Exchange (ETDEWEB)
Data which have been collected by Los Alamos National Laboratory waste management for the hydrologic characterization of the subsurface at the low level radioactive waste disposal facility, Area G, are reported and discussed briefly. The data includes Unsaturated Flow Apparatus measurements of the unsaturated conductivity in samples from borehole G-5. Analysis compares these values to the predictions from van Genuchten estimates, and the implications for transport and data matching are discussed, especially at the location of the Vapor Phase Notch (VPN). There, evaporation drives a significant vapor flux and the liquid flux cannot be measured accurately by the UFA device. Data also include hydrologic characterization of samples from borehole G-5, Area G surface soils, Los Alamos (Cerros de Rio) basalt, Tsankawi and Cerro-Toledo layers, the Vapor Phase Notch (VPN), and additional new samples from the uppermost tuff layer at Area G. Hydraulic properties from these ...
1998-03-01
Steady-state film-boiling data in rod-bundle geometry and non-equilibrium correlation assessment
Energy Technology Data Exchange (ETDEWEB)
A series of 22 steady-state, rod bundle, dispersed flow film boiling experiments has been performed in the Thermal-Hydraulic Test Facility (THTF), a pressurized-water loop containing 64 full-length electrically heated rods. Test parameters in the upflow experiments cover a wide range of conditions typical of those which might be encountered during a nuclear reactor loss-of-coolant accident. Local equilibrium fluid conditions were calculated using mass and energy conservation considerations. Experimentally determined heat transfer coefficients were compared to several available film boiling heat transfer correlations: Dougall-Rohsenow, Groeneveld 5.7, Groeneveld-Delorme, Chen, Jones-Zuber, and Yoder-Rohsenow. The Groeneveld 5.7 correlation tended to predict the data better than any other correlation tested. The Dougall-Rohsenow correlation tends to overpredict the data while the Yoder-Rohsenow correlation predicted the data better than the other ...
1982-01-01
International Nuclear Information System (INIS)
During the past 2 yr, significant progress has been made in several areas related to the safety and environmental (S and E) aspects of inertial fusion energy (IFE). An updated methodology has been developed, and accident analyses have been performed for two IFE conceptual power plants and a target fabrication facility. Parallel to the consequence analyses of different accident scenarios, ongoing studies of accident initiating events are being used to support safety assessment and create a basic framework of types of events to consider in future risk characterization of new plant designs. Target designers/fabrication specialists have been provided with ranking information related to the S and E characteristics of candidate target materials. We have revisited waste management options for IFE, introducing the concept of clearance versus the traditional shallow land burial. A brief summary of results in each of these activities ...
2003-05-01
Record of principal work activities/deliverables
International Nuclear Information System (INIS)
Over the five year period of performance, thirteen task assignments were issued by the DOE to ARINC Research. During the two year base period seven tasks were assigned. Two task assignments were issued for each of the three consecutive one year option periods. Associated with all task assignments were multiple subtasks, some of which required significant effort. These subtasks are appropriately cited in this report under their respective task assignments as principal work activities or deliverables. The technical and management support provided to the DOE under this contract focused on two general areas: (1) appraisal activities and (2) non-appraisal activities. Support to appraisals included planning, document review, developing lines-of-inquiry, interviewing, data collection, report writing, and follow-up. Such work was executed both on-site at the DOE facility under review and off-site. Non-appraisal support was varied and included such ...
2003-09-07
International Nuclear Information System (INIS)
This paper examines the attractiveness of material mixtures containing special nuclear materials (SNM) associated with reprocessing and the thorium-based LWR fuel cycle. This paper expands upon the results from earlier studies that examined the attractiveness of SNM associated with the reprocessing of spent light water reactor (LWR) fuel by various reprocessing schemes and the recycle of plutonium as a mixed oxide (MOX) fuel in LWR. This study shows that "2"3"3U that is produced in thorium-based fuel cycles is very attractive for weapons use. Consistent with other studies, these results also show that all fuel cycles examined to date need to be rigorously safeguarded and provided moderate to high levels of physical protection. These studies were performed at the request of the United States Department of Energy (DOE), and are based on the calculation of 'attractiveness levels' that has been couched in terms chosen for consistency with those normally used for ...
In field nuclear forensics: An overview of applicable instrumentation
International Nuclear Information System (INIS)
Recent seizures of nuclear materials, and particularly of fissionable nuclear materials, have resulted in an increased awareness of the need for fieldable instrumentation for the detection and characterization of suspect packages and materials. The ability to perform in-field assessments of materials contained in suspect packages is important for several reasons. First, and most importantly, determination of the type and quantity of material provides information critical to personnel safety. The personnel at potential risk may include both the general population in the area of the package and incident response personnel. Additionally, it would be advantageous to gain information that could result in attribution of the suspect package to a particular facility or pathway as soon as possible after interception. Limited access to a suspect package could also require the use of fieldable characterization instrumentation as ...
1997-06-12
GENERAL REQUIREMENTS FOR SIMULATION MODELS IN WASTE MANAGEMENT
Most waste management activities are decided upon and carried out in a public or semi-public arena, typically involving the waste management organization, one or more regulators, and often other stakeholders and members of the public. In these environments, simulation modeling can be a powerful tool in reaching a consensus on the best path forward, but only if the models that are developed are understood and accepted by all of the parties involved. These requirements for understanding and acceptance of the models constrain the appropriate software and model development procedures that are employed. This paper discusses requirements for both simulation software and for the models that are developed using the software. Requirements for the software include transparency, accessibility, flexibility, extensibility, quality assurance, ability to do discrete and/or continuous simulation, and efficiency. Requirements for the models that are developed include traceability, transparency, ...
2003-02-27
ARIES-AT safety design and analysis
Energy Technology Data Exchange (ETDEWEB)
ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather ...
2006-01-15
ARIES-AT safety design and analysis
International Nuclear Information System (INIS)
ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather ...
2006-01-01
International Nuclear Information System (INIS)
There has been recent interest in the United States concerning the loss of residual heat removal system (RHRS) under reduced coolant inventory conditions for pressurized water reactors. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-HI experimental facility at Siemens-KWU to supply applicable data. Recently, an NRC-sponsored effort has been undertaken at the Idaho-National Engineering Laboratory to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following the long term loss-of-RHRS during reduced inventory operation. The thermal-hydraulic response of a closed reactor coolant system during such a transient is investigated in this report. Some of the specific processes investigated include: reflux condensation in the steam generators, the corresponding pressure increase in the reactor coolant system, and void fraction distributions ...
1991-10-28
British Library Electronic Table of Contents (United Kingdom)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exc...
2010-01-01
FY 1986 current fiscal year work plan
Energy Technology Data Exchange (ETDEWEB)
This Current Year Work Plan presents in detail a description of the activities to be performed by the Joint Integration Office/RI during FY86. It breaks down the activities into two major work areas: Program Management and Program Analysis. Program Management is performed by the JIO/RI by providing technical planning and guidance for the development of advanced TRU waste management capabilities. This includes equipment/facility design, engineering, construction, and operations. These functions are integrated to allow transition from interim storage to final disposition. JIO/RI tasks include program requirements identification, long-range technical planning, budget development, program planning document preparation, task guidance development, task monitoring, task progress information gathering and reporting to DOE, interfacing with other agencies and DOE lead programs, integrating public involvement with program efforts, ...
1985-11-01
UK PubMed Central (United Kingdom)
BackgroundPhysical performance measures are widely used to assess physical function, providing information about physiological and biomechanical aspects of motor performance. However...Full Text Available
RCRA Facilities Assessment (RFA)---Oak Ridge National Laboratory
Energy Technology Data Exchange (ETDEWEB)
US Department of Energy (DOE) facilities are required to be in full compliance with all federal and state regulations. In response to this requirement, the Oak Ridge National Laboratory (ORNL) has established a Remedial Action Program (RAP) to provide comprehensive management of areas where past and current research, development, and waste management activities have resulted in residual contamination of facilities or the environment. This report presents the RCRA Facility Assessment (RFA) required to meet the requirements of RCRA Section 3004(u). Included in the RFA are (1) a listing of all sites identified at ORNL that could be considered sources of releases or potential releases; (2) background information on each of these sites, including location, type, size, period of operation, current operational status, and information on observed or potential releases (as required in Section II.A.1 of the RCRA ...
1987-03-01
Energy Technology Data Exchange (ETDEWEB)
The Next Generation Nuclear Plant (NGNP), a demonstration reactor and hydrogen production facility proposed for construction at the INEEL, is expected to be a high-temperature gas-cooled reactor (HTGR). Computer codes used in design and safety analysis for the NGNP must be benchmarked against experimental data. The INEEL and ANL have examined information about several past and present experimental and prototypical facilities based on HTGR concepts to assess the potential of these facilities for use in this benchmarking effort. Both reactors and critical facilities applicable to pebble-bed and prismatic block-type cores have been considered. Four facilities--HTR-PROTEUS, HTR-10, ASTRA, and AVR--appear to have the greatest potential for use in benchmarking codes for pebble-bed reactors. Similarly, for the prismatic block-type reactor design, two experiments have ...
2005-10-25
Energy Technology Data Exchange (ETDEWEB)
This document describes the geology and hydrogeology at the former Advanced Coal Liquefaction Research and Development (ACLR&D) facility in Wilsonville, Alabama. The work was conducted by personnel from the Oak Ridge National Laboratory Grand Junction office (ORNL/GJ) for the U.S. Department of Energy (DOE) Pittsburgh Energy Technology Center (PETC). Characterization information was requested by PETC to provide baseline environmental information for use in evaluating needs and in subsequent decision-making for further actions associated with the closeout of facility operations. The hydrogeologic conceptual model presented in this report provides significant insight regarding the potential for contaminant migration from the ACLR&D facility and may be useful during other characterization work in the region. The ACLR&D facility is no longer operational and has been dismantled. The site was ...
1996-09-01
Hot Cell Facility (HCF) Safety Analysis Report
Energy Technology Data Exchange (ETDEWEB)
This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important safety functions of each SSC are described. Additionally, information which ...
2000-11-01
Energy Technology Data Exchange (ETDEWEB)
Both the KRW fluidized-bed gasifier and the transport gasifier case studies were used for this assessment. The transport technology is a high-velocity circulating fluidized-bed reactor currently under development by The M.W. Kellogg Company. In the earlier assessment, seven design concepts or cases were identified; a process design was developed; major equipment items were identified; estimates of capital cost, operation and maintenance cost, and cost of electricity were developed; reliability was predicted; and development issues were identified for six studies. Three of the most probable cases were further evaluated for a Greenfield assessment in this report to adequately determine all costs independent of facilities at Plant Wansley.
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
Both the KRW fluidized-bed gasifier and the transport gasifier case studies were used for this assessment. The transport technology is a high-velocity circulating fluidized-bed reactor currently under development by The M.W. Kellogg Company. In the earlier assessment, seven design concepts or cases were identified; a process design was developed; major equipment items were identified; estimates of capital cost, operation and maintenance cost, and cost of electricity were developed; reliability was predicted; and development issues were identified for six studies. Three of the most probable cases were further evaluated for a Greenfield assessment in this report to adequately determine all costs independent of facilities at Plant Wansley.
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
The International Atomic Energy Agency (IAEA) started the Coordinated Research Program entitled ```The Safety Assessment of Near-Surface Radioactive Waste Disposal Facilities.`` The program is aimed at improving the confidence in the modeling results for safety assessments of waste disposal facilities. The program has been given the acronym NSARS (Near-Surface Radioactive Waste Disposal Safety Assessment Reliability Study) for ease of reference. The purpose of this report is to present the ORNL modeling results for the first test case (i.e., Test Case 1) of the IAEA NSARS program. Test Case 1 is based on near-surface disposal of radionuclides that are subsequently leached to a saturated-sand aquifer. Exposure to radionuclides results from use of a well screened in the aquifer and from intrusion into the repository. Two repository concepts were defined in Test Case 1: a simple earth ...
1993-07-01
Waste Receiving and Processing Facility Module 2A: Advanced Conceptual Design Report. Volume 1
Energy Technology Data Exchange (ETDEWEB)
This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.
1994-03-01
UK PubMed Central (United Kingdom)
Random amplified polymorphic DNA fingerprinting was performed to assess the genetic diversity among rarely cultivated traditional indica rice (Oryza sativa ...Full Text Available
Assessment of tennis elbow using the Marcy Wedge-Pro.
UK PubMed Central (United Kingdom)
The Marcy Wedge-Pro (MWP), a device used in training by tennis players, was employed in the assessment of tennis elbow. The MWP was used to measure the ability of patients to perform wrist extension...Full Text Available
1993-12-01
Advanced MRI Methods for Assessment of Chronic Liver Disease
UK PubMed Central (United Kingdom)
MRI plays an increasingly important role for assessment of patients with chronic liver disease. MRI has numerous advantages, including lack of ionizing radiation and the possibility of performing...Full Text Available
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these ...
2009-11-01
Long pulse chemical laser. Final technical report
Energy Technology Data Exchange (ETDEWEB)
This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation ...
1989-02-01
Energy Technology Data Exchange (ETDEWEB)
This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, ...
1988-09-01
International Nuclear Information System (INIS)
British Nuclear Fuels plc owns and operates the near-surface Drigg disposal facility for low level radioactive waste. The long-term performance of the site is modelled by a suite of computer codes called MONDRIAN. One of the modules of MONDRIAN deals with the transport of radionuclides through the environment, and this paper reports on the current status of this module (BIOS). We derive the basic set of working equations from first principles and show clearly how the approximate nature of the final equations is arrived at. This is done by an averaging process leading to compartments, in and out of which radionuclides, solids and water can flow. The equations allow radioactive decay chains and an arbitrary number of compartments. There is also the facility to deal with changes in the rate coefficients, thereby simulating different environmental states. It is also possible to include the creation of new compartments arising ...
2002-06-01
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made ...
2007-06-30
ETE-EVAL: a methodology for D and D cost estimation
International Nuclear Information System (INIS)
In compliance with Article 20 of the sustainable radioactive materials and waste management act dated 28 June 2006, the CEA and AREVA are required every three years to revise the cost of decommissioning their facilities and to provide the necessary assets by constituting a dedicated fund. For the 2007 revision the CEA used ETE-EVAL V5. Similarly, AREVA reevaluated the cost of decontaminating and dismantling its facilities at La Hague, as the previous estimate in 2004 did not take into account the complete cleanup of all the structural work. ETE-EVAL V5 is a computer application designed to estimate the cost of decontamination and dismantling of basic nuclear installations (INB). It has been qualified by Bureau Veritas and audited. ETE-EVAL V5 has become the official software for cost assessment of CEA civilian and AREVA decommissioning projects. It has been used by the DPAD (Decontamination and Dismantling Projects ...
Performance assessment overview for subseabed disposal of high level radioactive waste
Energy Technology Data Exchange (ETDEWEB)
The Subseabed Disposal Project (SDP) was part of an international program that investigated the feasibility of high-level radioactive waste disposal in the deep ocean sediments. This report briefly describes the seven-step iterative performance assessment procedures used in this study and presents representative results of the last iteration. The results of the performance are compared to interim standards developed for the SDP, to other conceptual repositories, and to related metrics. The attributes, limitations, uncertainties, and remaining tasks in the SDP feasibility phase are discussed.
1997-06-01
Acceptance test report for the Westinghouse 100 ton hydraulic trailer
Energy Technology Data Exchange (ETDEWEB)
The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.
1995-03-06
A study on the management of spent fuel storage capacity in South Korea
International Nuclear Information System (INIS)
The saturation of South Korea's at-reactor (AR) spent fuel storage pools will create a necessity for additional spent fuel storage capacity. Because the South Korean government has the plan to increase the number of nuclear power plants from 20 units (end of 2005) to 27 units by 2015, the increase of spent nuclear fuel generation will be accelerated. Because there is no clear national plan for spent nuclear fuel storage and disposal, the utility company (Korea Hydraulic Nuclear Power company) is planning to construct a spent fuel storage facility with 11 000 tHM capacity for Pressurised Water Reactor (PWR). This study is intended to predict the maximum allowable periods when the storage facility will be fully occupied with respect to the already fixed re-racking plan of spent fuel storage pools and construction of new nuclear power plants. The result from this study will be used as fundamental data for an efficient management of the spent fuel ...
2006-06-19
Systems analysis of the CANDU 3 Reactor
International Nuclear Information System (INIS)
This report presents the results of a systems failure analysis study of the CANDU 3 reactor design; the study was performed for the US Nuclear Regulatory Commission. As part of the study a review of the CANDU 3 design documentation was performed, a plant assessment methodology was developed, representative plant initiating events were identified for detailed analysis, and a plant assessment was performed. The results of the plant assessment included classification of the CANDU 3 event sequences that were analyzed, determination of CANDU 3 systems that are ''significant to safety,'' and identification of key operator actions for the analyzed events.
Routine environmental audit of the Y-12 Plant, Oak Ridge, Tennessee
Energy Technology Data Exchange (ETDEWEB)
This report documents the results of the routine environmental audit of the Oak Ridge Y-12 Plant (Y-12 Plant), Anderson County, Tennessee. During this audit, the activities conducted by the audit team included reviews of internal documents and reports from previous audits and assessments; interviews with U.S. Department of Energy (DOE), State of Tennessee regulatory, and contractor personnel; and inspections and observations of selected facilities and operations. The onsite portion of the audit was conducted August 22-September 2, 1994, by the DOE Office of Environmental Audit (EH-24), located within the Office of Environment, Safety and Health (EH). DOE 5482.1 B, {open_quotes}Environment, Safety, and Health Appraisal Program,{close_quotes} establishes the mission of EH-24 to provide comprehensive, independent oversight of DOE environmental programs on behalf of the Secretary of Energy. The ultimate goal of EH-24 is enhancement of environmental ...
1994-09-01
Ecological risk assessments for protected migratory birds and marine species at Midway Atoll
Energy Technology Data Exchange (ETDEWEB)
In June 1997, the US Navy plans to close its Naval Air Facility on Sand Island and transfer the atoll to the US Fish and Wildlife Service for use as a National Wildlife Refuge. Midway provides breeding and feeding habitat for migratory seabirds, terrestrial and marine mammals, sea turtles and other reptiles, and a variety of reef fishes and invertebrates. As part of the base closure and transfer process, 36 sites of potential environmental concern were identified on Sand and Eastern islands. These sites include landfills and uncontrolled disposal areas, hazardous materials storage areas, abandoned transformers, sewer outfalls, and other potential hazardous waste sites. Potential contaminants include pesticides, PAHs, PCBs, and heavy metals. A screening ecological risk assessment was performed at each site with a goal of determining whether contaminants could pose any current or future risks to protected migratory bird or ...
1995-12-31
Maintaining Quality Performance in a Rapidly Changing Workplace - NASA
360 degree Surveys. Measuring. Measuring successes successes ... Self- Assessment. Safeguards. Equipment. Reactor. Protection. Systems. Containment ...
International Nuclear Information System (INIS)
... feasibility studies fftf reactor loss of flow reactor control systems reactor core
1985-06-09
Confidence-Based Performance Assessments for the BMDO ...
... Notes Papers from the Proceedings AIAA 2nd Biennial ... Based (GB) Lower Tier Weapon System clearly ... are too short for space-based cueing to be ...
2001-03-27
International Nuclear Information System (INIS)
On March 31, 1995, the US Department of Energy filed a draft application for certification of compliance with the US Environmental Protection Agency (USEPA) to show the Waste Isolation Pilot Plant's compliance with the USEPA's environmental standards, making the application the first of its kind. Demonstration of compliance is by performance assessment. This paper is an early review of the performance assessment in the draft application, by the Environmental Evaluation Group, an oversight group. The performance assessment in the draft application is incomplete. Not all relevant scenarios have been analyzed. The calculation of potential consequences often does not use experimental data but rather estimates by workers developing additional data. The final compliance application, scheduled for October 1996 needs to consider additional scenarios, and be fully based ...
Advisory Committee for GPRA Performance Assessment (AC/GPA) Report FY2003
... impact. The Committee reviewed voluminous materials from NSF?s retrospective and prospective award ...
International Nuclear Information System (INIS)
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be favorably responsive and highly robust to ...
Risk evaluation system for facility safeguards and security planning
International Nuclear Information System (INIS)
The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planning assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily.
1987-07-12
A study on the design method of multi tunnels in geological disposal facility
International Nuclear Information System (INIS)
In the geological disposal facility of the high-level radioactive waste, a group of galleries is designed in parallel at the depth of more than 300 m below surface. This is an unprecedented structure in the field of conventional engineering, and it is necessary to take this characteristic into consideration in the design of the galleries. In the geological disposal facility, as well as ensuring the dynamic stability of the gallery during construction and operational periods, it is necessary to evaluate the EDZ adequately for long-term stability after the closure. In this study, analysis of the 'multi tunnels model' which represents the whole gallery group was performed and the results about the outbreak behavior of EDZ were summarized. (author)
2008-01-01
Design for environment for the National Ignition Facility
Energy Technology Data Exchange (ETDEWEB)
The National Ignition Facility (NIF) will be a U.S. Department of Energy (DOE) national center for inertial confinement fusion (ICF) and other research into the physics of high temperatures and high densities, and a vital element of the DOE`s nuclear weapons Stockpile Stewardship and Management Program. It will be used by scientists from a numerous different institutions and disciplines to support research advancements in national security, energy, basic science, and economic development. Multiple powerful laser beams will `ignite` small fusion targets, helping liberate more energy than is required to initiate the fusion reactions. This paper discusses the Design for Environment process for NIF, some of the subsequent activities resulting from the initial study, and a few of the lessons learned from this process. Subsequent activities include the development of a Pollution Prevention and Waste Minimization Plan (P2/WMin) for the facility, which ...
1998-05-01
Subcriticality calculations for the FFTF reverse approach to critical experiment
The reverse approach to critical (RAC) experiments were performed in the ZPR-IX critical facility at Argonne National Laboratory. One of the major objectives of this project is to determine the adequacy of the low-level flux monitor (LLFM) detectors for initial loading of the Fast Flux Test Facility (FFTF). 5 references. (auth)
1975-01-01
Quality assurance requirements for the design of nuclear fuel reprocessing facilities
International Nuclear Information System (INIS)
Requirements and guidance are provided for a quality assurance program for the design of nuclear fuel reprocessing facilities involving structures, systems and components whose satisfactory performance is required to prevent accidents that could cause undue risk to the health and safety of the public, or to mitigate the consequences of such accidents if they were to occur. The standard is to be used in conjunction with ANSI N46.2.
High temperature materials experience at the Central Receiver Test Facility
During four years of operation at the Central Receiver Test Facility (CRTF) ceramics have performed well in cyclic solar flux densities of less than 30 W/cm/sup 2/. Above 100 W/cm/sup 2/, serious limitations exist. Important application considerations include: the geometry, cyclic and long time exposures, flux density gradients, thermal shock, weathering, and soiling.
1982-01-01
Calculation of neutron source strength in Fast Flux Test Facility fuel as a function of irradiation
Energy Technology Data Exchange (ETDEWEB)
A method of calculating the neutron source strength in irradiated Fast Flux Test Facility (FFTF), fuel has been developed and is presented in this paper. This method has been used to perform calculations in support of the reactivity monitoring of the FFTF reactor by the modified source multiplication method during refueling operations. 31 refs.
1981-08-01
Energy Technology Data Exchange (ETDEWEB)
The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.
1992-01-01
UK PubMed Central (United Kingdom)
Total antioxidant performance (TAP) measures antioxidant capacities in both hydrophilic and lipophilic compartments of serum and interactions known to exist between them. Our objective was to assess...Full Text Available
2009-10-01
Performance assessment for EEG-based neonatal seizure detectors
UK PubMed Central (United Kingdom)
ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available
2011-03-01
Abstracts of recent reports: Maryland power plant research program 1992 through 1997
Energy Technology Data Exchange (ETDEWEB)
The goals of the program include predicting the impact of proposed new generating facilities, evaluating proposed high voltage transmission lines, assessing the impact of existing generating facilities, forecasting future demand for electric power, and investigating numerous information gaps through a long-range research program. The Power Plant Assessment Division (PPAD) is responsible for all PSC licensing support, site specific research, and radiological monitoring. The list of reports summarizes information of over 190 technical publications that represent the Program`s formalized research and monitoring efforts over the last five years. Reports are listed in chronological order by topical heading.
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
The operating histories and performance of a large (180 MWsub(e)) central condensing plant and five small (5 MWsub(e)) wellhead backpressure power plants are presented. The thermodynamic performance of the central plant is compared with an estimated possible performance based upon the work of Michaelides. Both types of plant have been shown to be reliable despite some problems due to the contaminants which are associated with geothermal steam.
1986-01-01
THE EFFECTS OF RESPONSE EFFORT ON SAFE PERFORMANCE BY THERAPISTS AT AN AUTISM TREATMENT FACILITY
UK PubMed Central (United Kingdom)
The effects of response effort on safe behaviors (i.e., glove wearing, hand sanitizing, and electrical outlet replacement) exhibited by therapists at an autism treatment center were examined. Participants...Full Text Available
2010-01-01
Mound Facility explosives incinerator
Energy Technology Data Exchange (ETDEWEB)
The design and performance of small incinerators used at the Mound Laboratory for the disposal of explosives are described. These units, which cost less than $1000 each, are about the size of a 55-gal drum, have water jackets for cooling, and have provided a flexible, efficient, and clean burning explosives disposal unit. (LCL)
1980-01-01
Hazard Evaluation and Technical Assistance Report No. TA 76-100, ASARCO, East Helena, Montana.
A Hazard Evaluation and Technical Assistance investigation was performed by NIOSH on February 1-4, 1977, at ASARCO, East Helena, Montana, a facility engaged in lead smelting. The survey was prompted by a request from the Regional OSHA Director in referenc...
1977-01-01
UK PubMed Central (United Kingdom)
BackgroundChina has had no effective and systematic information system to provide guidance for strengthening PHC (Primary Health Care) or account to citizens on progress. We report...Full Text Available
Subcritical Noise Analysis Measurements with Fresh and Spent Research Reactor Fuels Elements
Energy Technology Data Exchange (ETDEWEB)
The verification of the subcriticality is of utmost importance for the safe transportation and storage of nuclear reactor fuels. Transportation containers and storage facilities are designed such that nuclear fuels remain in a subcritical state. Such designs often involve excess conservatism because of the lack of relevant experimental data to verify the accuracy of Monte Carlo codes used in nuclear criticality safety analyses. A joint experimental research program between Oak Ridge National Laboratory, Westinghouse Safety Management Solutions, Inc., and the University of Missouri was initiated to obtain measured quantities that could be directly related to the subcriticality of simple arrays of Missouri University Research Reactor (MURR) fuel elements. A series of measurement were performed to assess the reactivity of materials such as BORAL, stainless steel, aluminum, and lead that are typically used in the construction ...
1999-02-01
Application of probabilistic methods to accident analysis at waste management facilities
International Nuclear Information System (INIS)
Probabilistic risk assessment is a technique used to systematically analyze complex technical systems, such as nuclear waste management facilities, in order to identify and measure their public health, environmental, and economic risks. Probabilistic techniques have been utilized at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, to evaluate the probability of a catastrophic waste hoist accident. A probability model was developed to represent the hoisting system, and fault trees were constructed to identify potential sequences of events that could result in a hoist accident. Quantification of the fault trees using statistics compiled by the Mine Safety and Health Administration (MSHA) indicated that the annual probability of a catastrophic hoist accident at WIPP is less than one in 60 million. This result allowed classification of a catastrophic hoist accident as ''not credible'' at WIPP per DOE definition. Potential uses of ...
International Nuclear Information System (INIS)
The Mixed Waste Management Facility, or MWMF, has been proposed as a national testbed facility for the demonstration and evaluation of technologies that are alternatives to incineration for the treatment of mixed low-level waste. The facility design will enable evaluation of technologies at pilot scale, including all aspects of the processes, from receiving and feed preparation to the preparation of final forms for disposal. The MWMF will reduce the risk of deploying such technologies by addressing the following: (1) Engineering development and scale-up. (2) Process integration and activation of the treatment systems. (3) Permitting and stakeholder issues. In light of the severe financial constraints imposed on the DOE and federal programs, DOE/HQ requested a study to assess the cost benefit for the MWMF given other potential alternatives to meet waste treatment needs. The MVVMF Project was asked to ...
2005-10-01
Long-term storage of Greater-Than-Class C Low-Level Waste
Energy Technology Data Exchange (ETDEWEB)
Under Federal law, the Department of Energy (DOE) is responsible for safe disposal of Greater-Than-Class C Low-Level Waste (GTCC LLW) generated by licenses of the Nuclear Regulatory commission (NRC) or Agreement States. Such waste must be disposed of in a facility licensed by the NRC. It is unlikely that licensed disposal of GTCC LLW will be available prior to the year 2010. Pending availability of disposal capacity, DOE is assessing the need for collective, long-term storage of GTCC LLW. Potential risks to public health and safety caused by long-term storage of GTCC LLW at the place of generation will be evaluated to determine if alternative facilities are warranted. If warranted, several options will be investigated to determine the preferred alternative for long-term storage. These options include modification of an existing DOE facility, development of a new DOE facility, or ...
1990-01-01
British Library Electronic Table of Contents (United Kingdom)
A dry interim storage facility has been constructed at the Wolsung power plant in Korea. This dry storage facility has seven separated modules. There are 40 long slender cylinders in one module. In one cylinder, ten baskets where sixty CANDU spent fuel bundles are loaded are stacked and stored. For this dry storage facility, analyses and tests for hypothetical accident conditions that might occur while moving and storing the baskets into a cylinder were performed. In a demonstration test, one of test basket models did not satisfy one of the safety-related requirements. Thus, the revised basket designs were generated using a structural evaluation based on finite element analyses and specimen tests. Among these revised designs, one design was chosen as a final revised basket design. The fina...
2011-01-01
CLOSURE OF THE FAST FLUX TEST FACILITY (FFTF) HISTORY & STATUS & FUTURE PLANS
Energy Technology Data Exchange (ETDEWEB)
In 1993, the US Department of Energy (DOE) decided to shut down the Fast Flux Test Facility (FFTF) due to lack of national missions that justified the annual operating budget of approximately $88M/year. The initial vision was to ''deactive'' the facility to an industrially and radiologically safe condition to allow long-term, minimal surveillance storage until approximately 2045. This approach would minimize near term cash flow and allow the radioactive decay of activated components. The final decontamination and decommissioning (D and D) would then be performed using then-current methodology in a safe and efficient manner. the philosophy has now changed to close coupling the initial deactivation with final D and D. This paper presents the status of the facility and focuses on the future challenge of sodium removal.
2006-02-24
Applications and benefits of the FFTF IEM cell training facility
Energy Technology Data Exchange (ETDEWEB)
The Interim Examination and Maintenance (IEM) Cell is located within the Fast Flux Test Facility (FFTF) Reactor Containment Building. This cell is a complex vertical hot cell whose purpose is to process reactor experiments and to perform maintenance on reactor and refueling components. Because access to this very complex cell is limited, a mock-up called the IEM Training Facility (IEMTF) has been developed. The IEMTF provides the IEM cell with many valuable benefits. Four of these benefits are: (1) development of alternate processing methods; (2) hands-on evaluation of equipment problems; (3) a ready source of verified parts, and (4) training facilities for IEM Cell technicians.
1982-05-01
Corrosion studies at the Wilsonville, Alabama, coal liquefaction facility during 1983
During 1983, Oak Ridge National Laboratory continued a study of materials performance at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility. Materials performance was evaluated by exposure and analysis of corrosion coupons and U-bend specimens, chemical analysis of related process streams, and ultrasonic determination of the thickness of walls of various components. The results of these studies are useful to current plant operators and to designers of future large-scale plants. 18 references, 4 figures, 12 tables.
1984-10-01
International Nuclear Information System (INIS)
National Nuclear Safety Department is authorized by Infra (Iranian Nuclear Regulatory Authority) for issuing rules and regulation and conducting the licensing and supervisory process for nuclear facilities. The main responsibilities of the NNSD are conducted via five main division are, nuclear codes and standards, Nuclear Safety assessment, Authorization, Inspection and Enforcement and Technical Support. In this paper, the functions and responsibilities of TSD in enhancing nuclear safety are described. Examples of main tasks to support the Nuclear Safety assessment division regarding to technical calculations and research of safety issues in licensing documents are provided. (author)
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
As part of the ICAP (International Code Assessment and Applications Program) agreement between ECN (Netherlands Energy Research Foundation) and USNRC, ECN has performed a number of assessment calculations for the thermohydraulic system analysis code RELAP5/MOD2/36.05. This document describes the assessment of this computer program versus a natural circulation experiment as conducted at the Borssele Nuclear Power Plant. The results of this comparison show that the code RELAP5/MOD2 predicts well the natural circulation behaviour of Nuclear Power Plant Borssele.
1993-07-01
Radionuclide release rates from spent fuel for performance assessment modeling
Energy Technology Data Exchange (ETDEWEB)
In a scenario of aqueous transport from a high-level radioactive waste repository, the concentration of radionuclides in water in contact with the waste constitutes the source term for transport models, and as such represents a fundamental component of all performance assessment models. Many laboratory experiments have been done to characterize release rates and understand processes influencing radionuclide release rates from irradiated nuclear fuel. Natural analogues of these waste forms have been studied to obtain information regarding the long-term stability of potential waste forms in complex natural systems. This information from diverse sources must be brought together to develop and defend methods used to define source terms for performance assessment models. In this manuscript examples of measures of radionuclide release rates from spent nuclear fuel or analogues of nuclear fuel are presented. ...
1994-11-01
Benchmarking of refinery emissions performance : Executive summary
International Nuclear Information System (INIS)
This study was undertaken to collect emissions performance data for Canadian and comparable American refineries. The objective was to examine parameters that affect refinery air emissions performance and develop methods or correlations to normalize emissions performance. Another objective was to correlate and compare the performance of Canadian refineries to comparable American refineries. For the purpose of this study, benchmarking involved the determination of levels of emission performance that are being achieved for generic groups of facilities. A total of 20 facilities were included in the benchmarking analysis, and 74 American refinery emission correlations were developed. The recommended benchmarks, and the application of those correlations for comparison between Canadian and American refinery performance, were ...
2003-01-01
Overview of IAEA year 2000 activities in the Department of Safeguards
International Nuclear Information System (INIS)
The IAEA Department of Safeguards established a project in 1996 for the year 2000 (Y2K) conversion activities. This project covered assessment, conversion and testing of the software applications, instrument evaluation software, embedded systems and Personal Computer (PC) hardware attached to various equipment. Significant progress has been made in converting the applications and instruments to be year 2000 compliant. At the same time Member states have made an effort as well in converting the systems used jointly at the facilities
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
The issues of the geothermal resource at Brady's Hot Springs are dealt with: the prospective supply of feedstocks to the ethanol plant, the markets for the spent grain by-products of the plant, the storage, handling and transshipment requirements for the feedstocks and by-products from a rail siding facility at Fernley, the probable market for fuel ethanol in the region, and an assessment of the economic viability of the entire undertaking.
1980-09-01
Environmental Assessment of the Relocation and Construction of a Military Working Dog (MWD) Kennel.
The United States Air Force (USAF) 460th Space Wing (460 SW) proposes to relocate and construct a Military Working Dog (MWD) kennel facility on Buckley Air Force Base (AFB) in response to changing land use surrounding the existing kennel and to accommodat...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
A couple of domestic institutions have been investigating the application of vitrification technology to treat low- and intermediate-level radioactive wastes in Korea. In the case that such investigations prove to be successful, it is expected that commercial vitrification plants will be constructed. The safety insuring on vitrification plants could not be compatible with criterion on radioactive waste management because the facilities are at high temperature and contain a variety of accommodations for the exhaust gases and residual products. Therefore, it is necessary to suggest a new strategy or modifications of criterion of radioactive waste management on considerations related with the vitrification technology. In order to ensure the safety of vitrification plants, a technical guideline or standard for design and operation of vitrification plants must be established too. A study on the safety assessment of vitrification plants in ...
2003-02-25
Should high-level nuclear waste be disposed of at geographically dispersed sites?
Energy Technology Data Exchange (ETDEWEB)
Consideration of the technical feasibility of Yucca Mountain in Nevada as the site for a high-level nuclear waste repository has led to an intense debate regarding the economic, social, and political impacts of the repository. Impediments to the siting process mean that the nuclear waste problem is being resolved by adhering to the status quo, in which nuclear waste is stored at scattered sites near major population centers. To assess the merits of alternative siting strategies--including both the permanent repository and the status quo- we consider the variables that would be included in a model designed to select (1) the optimal number of disposal facilities, (2) the types of facilities (e.g., permanent repository or monitored retrievable facility), and (3) the geographic location of storage sites. The objective function in the model is an all-inclusive measure of social cost. The intent of the ...
1992-07-01
International Nuclear Information System (INIS)
Shut-off rod drive mechanism forms a safety critical system of a nuclear reactor. It is the space constraints for the given reactor layout, which makes design of shut-off rod drive mechanism (SRDM) a custom built design. Design of SRDM adopts fail-safe, replaceability and the simplicity criterion ensuring very high reliability of its operation. Shut-off rod drive mechanism for TAPP-3 and 4 and 'Critical Facility' have been recently designed and developed at Division of Remote Handling and Robotics (DRHR), BARC. These are designed with a number of advanced features and these are significantly different than those used in Dhruva and 220 MWe PHWRs. Design of SRDM is qualified through proto typing and life cycle testing on a full-scale test set-up. This paper gives details of qualification and life cycle test data for prototype SRDM for TAPP-3 and 4 and 'Critical Facility' and reliability assessment. (author)
2005-12-01
This report provides test results on the thermal performance of an Owens-Illinois Sunpak liquid, evacuated tube, solar collector under simulated conditions. The test was conducted using the Marshall Space Flight Center Solar Simulator in accordance with the test requirements specified in ASHRAE 93-77 (Method of Testing to Determine the Thermal Performance of Solar Collectors) and the procedures contained in MTCP-FA-SHAC-400 (Procedure for Operation of the MSFC Solar Simulator Facility). The tests were performed on a module used on the early demonstration projects. A current production module is undergoing tests with results to be in a subsequent report.
1979-10-10
Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils
Energy Technology Data Exchange (ETDEWEB)
BC Hydro has been assessing and upgrading its facilities and implementing response alternatives to potential damage resulting from a major earthquake. This paper reviews the utility`s seismic evaluation of its overhead transmission system, focusing on the Lower Mainland area where most of the tall critical river-crossing towers are located. The paper gives an overview of the geologic environment of the Lower Mainland and outlines the criteria used for assessing existing structures for their ability to withstand design seismic loads. It then describes the investigation and analysis methods used in the assessment, including geotechnical field tests, ground response analysis, determination of soil liquefaction potential, and dynamic analysis of structures and piles. Options for seismic upgrades are discussed and illustrated by the case of the Pitt River crossing, where tower foundations were reinforced ...
1995-12-31
The overarching goals of the 'Kootenai River Floodplain Ecosystem Operational Loss Assessment, Protection, Mitigation and Rehabilitation' Project (BPA Project No.2002-011-00) are to: (1) assess abiotic and biotic factors (i.e., geomorphologic, hydrological, aquatic and riparian/floodplain communities) in determining a definitive composition of ecological integrity, (2) develop strategies to assess and mitigate losses of ecosystem functions, and (3) produce a regional operational loss assessment framework. To produce a scientifically defensible, repeatable, and complete assessment tool, KTOI assembled a team of top scientists in the fields of hydrology, hydraulics, ornithology, entomology, statistics, and river ecology, among other expertise. This advisory team is known as the Research Design and Review Team (RDRT). The RDRT scientists drive the review, selection, ...
2009-02-18
The HIPAA privacy rule (HIPAA) has had both positive and negative effects on the release of patient information by healthcare facilities. Although the intention of HIPAA was to protect patient privacy and to promote security and confidentiality of patient information, it has had unintended consequences for facilities. To identify some of these unintended effects, two expert panels of health information management directors from healthcare facilities participated in the nominal group technique meetings. They identified 70 barriers related to release of patient information associated with the implementation of HIPAA. The perceived biggest barriers were increases in the public's misunderstanding about release of patient information, lack of an umbrella policy or regulation defining infractions and enforcement that allows individual institutions to make their own interpretations, and challenges to health information management ...
2007-03-23
Energy Technology Data Exchange (ETDEWEB)
The Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0804, for the proposed replacement of a deteriorated brine disposal pipeline from the Strategic Petroleum Reserve (SPR) Bryan Mound storage facility in Brazoria County, Texas, into the Gulf of Mexico. In addition, the ocean discharge outfall would be moved shoreward by locating the brine diffuser at the end of the pipeline 3.5 miles offshore at a minimum depth of 30 feet. The action would occur in a floodplain and wetlands; therefore, a floodplain/wetlands assessment has been prepared in conjunction with this EA. Based on the analyses in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969 (42 USC. 4321, et seg.). Therefore, the preparation of an Environmental Impact Statement ...
1993-09-01
Field-effect research at the High Voltage Transmission Research Center
Energy Technology Data Exchange (ETDEWEB)
This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped out strands, are analyzed for the purpose of determining the conditions for occurrence ...
1991-02-01
International Nuclear Information System (INIS)
Based on the occurrence of a number of plant incidents during low power and shutdown operating conditions, the Nuclear Regulatory Commission (NRC) has initiated several programs to better quantify risk during these periods. One specific issue of interest is the loss of residual heat removal (RHR) under reduced coolant inventory conditions. This issue is also of interest in the Federal Republic of Germany and an experiment was performed in the integral PKL-3 experimental facility at Siemens-KWU to supply applicable data. Recently, an effort has been undertaken at the Idaho National Engineering Laboratory (INEL) to identify and analyze the important thermal-hydraulic phenomena in pressurized water reactors following loss of vital AC power and consequent loss of the RHR system during reduced inventory operation. The thermal-hydraulic response of a nuclear steam supply system (NSSS) with a closed reactor coolant system (RCS) to loss of residual ...
1991-10-01
SSHS - Departments - Taught Courses - Undergraduate Prospectus - Loughborough University
... Indoor facilities include a 50 metre swimming pool, various sports halls, a netball and badminton centre, a dance studio, a high performance athletics centre, the ECB National Cricket Academy, and the National Gymnastics Performance and Research Centre, whilst outdoors there are floodlit all-weather areas, a water-based ...
Performance testing of the FMC Fresnel-Belt Concentrating Solar Collector
Energy Technology Data Exchange (ETDEWEB)
The results of tests performed on the FMC Fresnel-Belt Solar Collector at the Midtemperature Solar Systems Test Facility are summarized. Tests were conducted over a temperature range from 100 to 250/sup 0/C. Test objectives are defined, test procedures are described, and test results and conclusions are given.
1980-01-01
Fast reactor fuel pin performance requirements for off-normal events
International Nuclear Information System (INIS)
HEDL is conducting an experimental transient testing program to evaluate the performance of prototypic Fast Flux Test Facility (FFTF) fuel pins up to the cladding integrity limit. The relationship is described of the HEDL/TREAT transient overpower test program to the confirmation of FFTF fuel pin design bases via the FFTF fuel pin design procedure.
Nuclear safety culture star-class assessment system based BP neural network
International Nuclear Information System (INIS)
In order to build the safety culture for nuclear power industry, it is important to evaluate the safety culture scientifically. Considering the traits of safety culture in the nuclear power industry, 24 safety culture assessment indexes are established from 4 aspects such as Safety consciousness, Safety attitude, Safety action and Safety actuality by using the SMART criteria. Safety culture star-class assessment criterion is presented and safety culture star-class assessment system is developed by using Visual Basic 6.0 and BP neural network. The system has a better generalization ability, and it can show exactly which phase the safety culture is in. Experimental results show that safety culture star-class assessment is practical and easy to perform. (authors)
2007-02-01
Methodology for assessing performance of waste management systems
Energy Technology Data Exchange (ETDEWEB)
The purpose of the methodology provided in this report is to select the optimal way to manage particular sets of waste streams from generation to disposal in a safe and cost-effective manner. The methodology described is designed to review the entire waste management system, assess its performance, ensure that the performance objectives are met, compare different LLW management alternatives, and select the optimal alternative. The methodology is based on decision analysis approach, in which costs and risk are considered for various LLW management alternatives, a comparison of costs, risks, and benefits is made, and an optimal system is selected which minimizes costs and risks and maximizes benefits. A ''zoom-lens'' approach is suggested, i.e., one begins by looking at gross features and gradually proceeds to more and more detail. Performance ...
1988-01-01
Waste sampling and characterization facility (WSCF)
Energy Technology Data Exchange (ETDEWEB)
The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain very low concentrations ...
1994-10-01
Energy Technology Data Exchange (ETDEWEB)
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to ...
1990-03-01
International Nuclear Information System (INIS)
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular ...
1988-08-01
A combined cycle engine test facility
Energy Technology Data Exchange (ETDEWEB)
Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in which the propulsive force was generated by rocket only, the ramjet only and ...
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
Green Building Challenge (GBC) was intended to advance the state-of-the-art of building performance assessment, through the development, testing, and discussion of an assessment framework, criteria and tool. The contributions of GBC to building performance assessment are considered through comparing similarities and differences with a selection of available assessment tools. Unlike national or proprietary assessment systems, GBC was not designed for application to specific commercial markets. Instead, it emphasized research and involved researchers and practitioners from many countries. Consequently, GBC has been in a unique position to test and adopt new ideas and implement step changes. GBC's roles over the past five years have been to provide a reference framework, method and tools that can be used to develop new systems or ...
2001-09-01
Energy Technology Data Exchange (ETDEWEB)
Before disposing of transuranic radioactive wastes in the Waste Isolation Pilot Plant (WIPP), the United States Department of Energy (DOE) must evaluate compliance with applicable long-term regulations of the United States Environmental Protection Agency (EPA). Sandia National Laboratories is conducting iterative performance assessments of the WIPP for the DOE to provide interim guidance while preparing for final compliance evaluations. This volume contains an overview of WIPP performance assessment and a preliminary comparison with the long-term requirements of the Environmental Radiation Protection Standards for Management and Disposal of Spent Nuclear Fuel, High-Level and Transuranic Radioactive Wastes (40 CFR 191, Subpart B).
1992-12-01
Energy Technology Data Exchange (ETDEWEB)
A summary of the 1983 Critical Solvent Deashing unit performance at the Wilsonville Advanced Coal Liquefaction R and D Facility is presented. All periods of on feed operation, unscheduled shutdowns, and scheduled shutdowns are accounted for and tabulated. Causes of unscheduled shutdowns are identified and discussed. Details of repeated, major maintenance problems with various pieces of equipment are presented. Where applicable, solutions are discussed. Historical operations and maintenance data are presented and used for comparison purposes in order to better indicate areas of improvement in the unit. 4 references, 7 figures, 3 tables.
1985-03-01
International Nuclear Information System (INIS)
The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.
The ANL X6B beamline at NSLS: A versatile facility
Energy Technology Data Exchange (ETDEWEB)
We have described the x-ray optics and beamline performance of the ANL X6B beam line at the NSLS. Considerable flexibility has been built into the beam line to accommodate a wide range of x-ray diffraction, scattering, and spectroscopy experiments with various requirements. We presented selected examples of experimental results and showed that with the high intensity, high energy resolution, high-q resolution, and energy tunability, the X6B beam line has become a versatile facility.
1994-07-01
Testing of the 1-MWth bench-model cavity-receiver steam generator
A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)
Performance of rubber heat-stable and radiation-stable seals in helium coolant lines
International Nuclear Information System (INIS)
The integrity of helium circulation loop flanged joints has been attracting recent attention as a design problem, in the development of high-temperature facilities incorporating helium loops (e.g., the VRG-50 pilot nuclear facility). Elevated temperatures and pressures, and the radiation environment, impose additional requirements on sealant materials. This applies first and foremost to rubber seals, which have found widespread favor on account of its excellent elasticity, its ability to spontaneously conform to possible changes in the clearance in the seal assembly, and the low compressive stresses developed in the flange joint assembly.
Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF
International Nuclear Information System (INIS)
An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.
2010-01-01
FFTF (Fast Flux Test Facility) Reactor Characterization Program: Absolute Fission-rate Measurements
Energy Technology Data Exchange (ETDEWEB)
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
1981-05-01
FFTF (FAST FLUX TEST FACILITY) REACTOR CHARACTERIZATION PROGRAM ABSOLUTE FISSION RATE MEASUREMENTS
Energy Technology Data Exchange (ETDEWEB)
Absolute fission rate measurements using modified National Bureau of Standards fission chambers were performed in the Fast Flux Test Facility at two core locations for isotopic deposits of {sup 232}Th, {sup 233}U, {sup 235}U, {sup 238}U, {sup 237}Np, {sup 239}Pu, {sup 240}Pu, and {sup 241}Pu. Monitor chamber results at a third location were analyzed to support other experiments involving passive dosimeter fission rate determinations.
1981-05-01
Estimating the tritiated hydrocarbon decontamination factor by heavy methane
International Nuclear Information System (INIS)
As part of the start up of Los Alamos National Laboratory's new tritium-handling facility, the efficiency of a catalytic oxidation tritium decontamination system was investigated using deuterated methane. The tests were performed during the start up of the facility to confirm the operability of the system before introducing tritium and to provide a baseline for comparison. Techniques and instruments normally used for atmospheric tracer experiments using deuterated methane were applied virtually without modification. The sensitivity of this method allowed preliminary checks at the sub-ppm (v/v) level.
Conceptual design of a nuclear reactor facility for medical and biological purposes
Energy Technology Data Exchange (ETDEWEB)
Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented.
1981-09-01
Conceptual design of a nuclear reactor facility for medical and biological purposes
International Nuclear Information System (INIS)
Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented. (author).
Bechtel Hanford Inc. Network Security Plan for the EnvironmentalRestoration Contract
'As part of the Computer Protection Plan, this Network Security Plan identifies the specific security measures used to protect Bechtel Hanford, Inc.'s (BHI's) enterprise network. The network consists of the communication infrastructure and information systems used by BHI to perform work related to the Environmental Restoration Contract (ERC) at the Hanford Site. It provides electronic communication between the ERC-leased facilities in Richland, Washington, and facilities located on the Hanford Site. Network gateways to other site and offsite networks provide electronic communication with the remainder of the Hanford community.'
1999-06-30
Analysis of tritium mission FMEF/FAA fuel handling accidents
Energy Technology Data Exchange (ETDEWEB)
The Fuels Material Examination Facility/Fuel Assembly Area is proposed to be used for fabrication of mixed oxide fuel to support the Fast Flux Test Facility (FFTF) tritium/medical isotope mission. The plutonium isotope mix for the new mission is different than that analyzed in the FMEF safety analysis report. A reanalysis was performed of three representative accidents for the revised plutonium mix to determine the impact on the safety analysis. Current versions computer codes and meterology data files were used for the analysis. The revised accidents were a criticality, an explosion in a glovebox, and a tornado. The analysis concluded that risk guidelines were met with the revised plutonium mix.
1997-11-18
Pacific Northwest Laboratory Maintenance Implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation plan has been developed for Pacific Northwest Laboratory's (PNL) Nuclear Facilities: 306W, 324, 325, 327 and 329NMF. It is based on a graded approach, self-assessment of the existing maintenance program(s) per the requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter II, Change {number sign}3. The results of this assessment were evaluated to determine needed improvements in PNL Craft Services' current maintenance program. The objective of this implementation plan is to provide baseline information for compliance to the DOE 4330.4A, and for needed improvements. The prime consideration in applying a graded approach to the Order has been to maintain safe and reliable operations, environmental compliance, safeguards and security, programmatic mission, facility preservation, and/or other facility-specific ...
1992-06-01
Pacific Northwest Laboratory Maintenance Implementation plan
Energy Technology Data Exchange (ETDEWEB)
This Maintenance Implementation plan has been developed for Pacific Northwest Laboratory`s (PNL) Nuclear Facilities: 306W, 324, 325, 327 and 329NMF. It is based on a graded approach, self-assessment of the existing maintenance program(s) per the requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter II, Change {number_sign}3. The results of this assessment were evaluated to determine needed improvements in PNL Craft Services` current maintenance program. The objective of this implementation plan is to provide baseline information for compliance to the DOE 4330.4A, and for needed improvements. The prime consideration in applying a graded approach to the Order has been to maintain safe and reliable operations, environmental compliance, safeguards and security, programmatic mission, facility preservation, and/or other facility-specific requirements. Using the ...
1992-06-01
Energy Technology Data Exchange (ETDEWEB)
A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)
1980-07-01
The {sup 234}U neutron capture cross section measurement at the n TOF facility
Energy Technology Data Exchange (ETDEWEB)
The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)
2008-07-01
The status of the alpha-project
International Nuclear Information System (INIS)
A review of the ALPHA project is presented, including a summary of progress and current status. The project comprises the experimental and analytical investigation of the long-term decay heat removal phenomena from the containment of the next generation of ''passive'' Advanced Light Water Reactors. The effects of aerosols that may result from hypothetical severe accidents are also considered. The construction of the major ALPHA experimental facilities, PANDA, LINX-2 and AIDA, has been completed. First steady-state tests have been performed on PANDA. The other facilities are now in their commissioning phases. Scaling studies have guided the design of the experimental facilities. Several small-scale experimental and studies have already produced valuable results which can be used to direct the experimental work, as well as the design of the passive ALWRs. (author). 23 refs, 6 figs.
1996-04-01
The PANDA tests for SBWR certification
International Nuclear Information System (INIS)
The ALPHA project is centered around the experimental and analytical investigation of the long-term decay heat removal from the containments of the next generation of open-quotes passiveclose quotes ALWRs. The project includes integral system tests in the large-scale (1:25 in volume) PANDA facility as well as several other series of tests and supporting analytical work. The first series of experiments to be conducted in PANDA have become a required experimental element in the certification process for the General Electric Simplified Boiling Water Reactor (SBWR). The PANDA general experimental philosophy, facility design, scaling, and instrumentation are described. Steady-state PCCS condenser performance tests and extensive facility characterization tests were already conducted. The transient system behavior tests are underway; preliminary results from the first transient test M3 are reviewed.
1996-03-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the status of nuclear safety and radiation protection in the facilities of the AREVA group and gives information on radiation protection in the service operations, as observed through the inspection programs and analyses carried out by the General Inspectorate in 2007. Having been submitted to the group's Supervisory Board, this report is sent to the bodies representing the personnel. Content: 1 - A look back at 2007 by the AREVA General Inspector: Visible progress in 2007, Implementation of the Nuclear Safety Charter, Notable events; 2 - Status of nuclear safety and radiation protection in the nuclear facilities and service operations: Personnel radiation protection, Event tracking, Service operations, Criticality control, Radioactive waste and effluent management; 3 - Performance improvement actions; 4 - Description of the General Inspectorate; 5 - Glossary.
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
This study characterized selected commercial volume reduction technologies as to performance and associated costs. VR facility designs were developed for each of the reference VR technologies. Associated on-site storage requirements and cost were also determined. Eight VR technologies were selected for consideration: improved compactor; high pressure compactor (supercompactor); incinerator; fluid bed dryer and incinerator; evaporator crystallizer; evaporator extruder; mobile incinerator; and mobile thin-film evaporator. A representative facility design was developed for each VR technology and for several combinations of technologies. Thirteen separate cases are noted in the following table when retrofit and new facilities are considered.
1984-11-01
Coal-liquefaction-process research quarterly report, January 1 - March 31, 1982
Objectives of the program are to understand the mechanisms of coal liquefaction, to determine the role of catalysts in the direct conversion of coal to liquids, to determine the mechanism of catalyst deactivation and to explore slurry phase catalyst systems. Specific projects include: short-contact time coal liquefaction, mineral matter effects and catalyst studies. During this period, work was performed on: (1) the stability, at reaction temperature, of a recycle solvent obtained from the Lummus Two Stage Liquefaction facility, (2) reactions of preasphaltenes and asphaltenes prepared under various reaction severities, (3) the evaluation of the catalyst level detector installed at the H-Coal facility, (4) the characterization of oil soluble metal compounds with respect to hydrogenation activity, and (5) characterization, deactivation and regeneration of catalysts obtained from both the H-Coal and Lummus ...
1982-10-01
Validation studies of thermal-hydraulic code for safety analysis of nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The thesis gives an overview of the validation process for thermal-hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. Large part of the work has been performed in cooperation with the CATHARE-team in Grenoble, France. (41 refs., 11 figs., 8 tabs.).
1995-12-31
INTERFACIAL AREA TRANSPORT AND REGIME TRANSITION IN COMBINATORIAL CHANNELS
Energy Technology Data Exchange (ETDEWEB)
. This study investigates the geometric effects of 90-degree vertical elbows and flow configurations in two-phase flow. The study shows that the elbows make a significant effect on the transport characteristics of two-phase flow, which includes the changes in interfacial structures, bubble interaction mechanisms and flow regime transition. The effect of the elbows is characterized for global and local two-phase flow parameters. The global two-phase flow parameters include two-phase pressure, interfacial structures and flow regime transition. In order to characterize the frictional pressure drop and minor loss across the vertical elbows, pressure measurements are obtained across the test section over a wide range of flow conditions in both single-phase and two-phase flow conditions. A two-phase pressure drop correlation analogous to Lockhart-Martinelli correlation is proposed to predict the minor loss across the elbows. A high speed camera is employed to perform ...
2011-01-28
In Home Occupational Performance Evaluation (I-HOPE)
OBJECTIVEThis study describes the development and preliminary psychometric properties of an assessment to quantify the magnitude of an environmental barrier's influence on occupational performance.METHODThe assessment was developed then piloted on a group of 77 older adults before and after an occupational therapy intervention focused on environmental barrier removal. Refinements were made to the assessment before it was evaluated for interrater reliability in a sample of 10 older adults using two raters.RESULTSThe In-Home Occupational Performance Evaluation (I-HOPE) is a performance based measure that evaluates 44 activities in the home. The four subscales of activity participation, client's rating of performance, client's satisfaction with performance, and severity of environmental barriers are sensitive to change in ...
2008-01-01
The potential for use of waste-to-energy facility ash: Executive summary. Final report
Energy Technology Data Exchange (ETDEWEB)
This executive summary presents an overview of the investigations, findings, conclusions, and recommendations of the Long Island Regional Planning Board (LIRPB) study of the Potential for Beneficial Use of Waste-to-Energy Facility Ash. The full report consists of the following volumes: Executive Summary; Volume 1: Long Island Ash Management Status; Volume 2: Sampling and Testing Procedures; Volume 3: Environmental Properties; Volume 4: Engineering Properties; Volume 5: Environmental Assessment; Volume 6: Engineering and Economic Evaluation; and Volume 7: Legal and Institutional Issues. Volumes one through seven are briefly summarized in this executive summary with the exception of Volume 2 of the report, which serves as the documentation of the sampling conditions and testing methods used in measuring chemical and physical properties of the ash tested. The study investigated the feasibility of the use of incinerator ash as a substitute for ...
1994-05-01
International Nuclear Information System (INIS)
The major degradation mechanisms acting during the aging of selected WWER-440/213 primary circuit facilities were assessed critically. The analysis gave evidence that such mechanisms include radiation and fatigue damage of the reactor pressure vessel (effect of the neutron flow, cyclic fatigue promoted by the corrosive medium, effect of thermal aging), corrosion-mechanical and thermo-mechanical (fatigue) damage of the steam generator (stress corrosion cracking, erosion corrosion, thermal aging, wear), thermal and dynamic aging of the pressurizer, and corrosion-mechanical damage of the primary circuit piping (thermal aging, corrosion). (J.B.). 5 tabs., 1 fig., 62 refs.
Analyses of eigenvalue bias and control rod worths in FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) core loading during its ninth operating cycle was significantly different from that of previous cycles because of the presence of the Core Demonstration Experiment (CDE). The CDE consists of a number of axially blanketed fuel assemblies and internal blankets prototypic of advanced oxide cores in Liquid Metal Reactors (LMR). In preparation for the Cycle 9 reload design effort, a careful assessment of control rod worth and reactivity calculations for Cycles 1 through 8 was made. The goal of this study was to establish calculational biases and reduce uncertainties factored into the reload design calculations. These analyses helped assure that the operational objectives for Cycle 9 were met.
1987-09-13
Analyses of eigenvalue bias and control rod worths in FFTF (Fast Flux Test Facility)
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) core loading during its ninth operating cycle was significantly different from that of previous cycles because of the presence of the Core Demonstration Experiment (CDE). The CDE consists of a number of axially blanketed fuel assemblies and internal blankets prototypic of advanced oxide cores in Liquid Metal Reactors (LMR). In preparation for the Cycle 9 reload design effort, a careful assessment of control rod worth and reactivity calculations for Cycles 1 through 8 was made. The goal of this study was to establish calculational biases and reduce uncertainties factored into the reload design calculations. These analyses helped assure that the operational objectives for Cycle 9 were met.
1987-01-01
Activation analysis of target debris in the national ignition facility
International Nuclear Information System (INIS)
The modeling methods used to compute the neutron-induced activation of target and near-target materials in the NIF facility are presented. A detailed space and energy description of the neutron environment in the different materials is provided. A new capability has been developed to treat in a general way the activation of debris produced in an operational regime of yield and no-yield experiments. First calculations are addressed to analyze the activity of the debris into the target chamber. The contribution of the different components to activity, interior dose rates, and waste disposal rating (WDR) is determined. The importance of the activation coming from primary irradiation in the target, and from secondary irradiation in debris deposited onto the first wall is assessed. Finally, waste hazards of the activated debris when removed out of the chamber and stored are analyzed. (authors)
1999-09-12
Supercomputers for solving PDE problems. Final report, 1 October 1985-31 March 1988
Energy Technology Data Exchange (ETDEWEB)
Researchers investigated several supercomputer architectures in the context of assessing their performance in solving PDE problems. Main results are: assessed various classes of paralled and vector supercomputers and parallel software issues toward solving PDE problems; developed a multipipeline networking technique for compound vector processing; developed an orthogonal multiprocessor for large-grain scientific computations; improved parallel efficiency of a domain decomposition method, the DD algorithm.
1988-11-01
WorId Ocean Circulation Experiment - OceanESIP - NASA
period T. Also shown is the returned chirp from a specular reflector at ...... algorithms is a Brown (1977) model of the return waveform, which assumes a ...... Townsend, W.F., 1980: An initial assessment of the performance achieved by ...
UK PubMed Central (United Kingdom)
The objectives of this research are: (1) to assess selected formulation-relevant physical properties of several commercial Feverfew extracts, including flowability, hygroscopicity, compressibility and...Full Text Available
UNEP will provide in the first CPR quarterly report of 2011 the financial statements for 2010. ...for assessing and rating programme performance UNEP to work with the CPR to identify better ways of streamlining reporting requirements ...in 2011 to achieve the ratios requested by the CPR dependent on receipt of contributions originally planned for the
Marine Ecosystem Analysis for Wolsung Nuclear Power Plant.
Environmental surveys to provide base-line data for assessing the potential impact of the operation of Wolseong NPP on marine ecosystems were performed at 3-month intervals in 1981. Physico-chemical properties of seawater and gross beta activities in seaw...
1982-01-01
Echocardiographic assessment and percutaneous closure of multiple atrial septal defects
UK PubMed Central (United Kingdom)
Atrial septal defect closure is now routinely performed using a percutaneous approach under echocardiographic guidance. Centrally located, secundum defects are ideal for device closure but there is...Full Text Available
Department of Energy low-level waste management strategy
Energy Technology Data Exchange (ETDEWEB)
The DOE strategy recognizes that public perception of low-level waste management practices is not positive. Actions are included that are aimed at opening the system to the public. A better informed public will be able to better assess the performance of the low-level waste management system.
1980-01-01
UK PubMed Central (United Kingdom)
PURPOSE The Wells rule is widely used for clinical assessment of patients with suspected deep vein thrombosis (DVT), especially in the secondary care setting. Recently a new clinical decision...Full Text Available
2011-01-01
UK PubMed Central (United Kingdom)
The attitudes and expectations of producers toward the use of a microcomputer-based herd management information system were assessed. The study was conducted over a two-year period, beginning in January...Full Text Available
1992-02-01
A boosting method for maximizing the partial area under the ROC curve
UK PubMed Central (United Kingdom)
BackgroundThe receiver operating characteristic (ROC) curve is a fundamental tool to assess the discriminant performance for not only a single marker but also a score function combining...Full Text Available
Air conditioner for radioactive material handling facility
Energy Technology Data Exchange (ETDEWEB)
An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly ...
1991-04-26
New aspects for the evaluation of radioactive waste disposal methods
International Nuclear Information System (INIS)
For the performance assessment of radioactive and hazardous waste disposal sites, risk assessments are usually performed for the long term, i.e., over an interval in space and time for which one can predict movement and behavior of toxic agents in the environment. This approach is based on at least three implicit assumptions: One, that the engineering layout will take care of the immediate endangerment of potential receptors; two, that one has carefully evaluated just how far out in space and time the models can be extrapolated, and three, that one can evaluate potential health effects for very low exposures. A few of these aspects will be discussed here in the framework of the scientific method.
1996-08-18
British Library Electronic Table of Contents (United Kingdom)
In this paper, the performance of customer-owned distributed generation (DG) units is quantified from different perspectives through an uncertainty study. A Monte Carlo-based method is applied to assess the stochastic operation of the customer-owned DG units in the power distribution system. Several cases are studied to analyze the impact on system performance of using such generators, with the emphasis on benefits. The results of the studied cases show that proper operation of customer-owned DG units placed close to significant consumption centers offers several benefits which lead to significant energy savings and improvement in the performance indices while maintaining the cost-effectiveness. Furthermore, based on the energy demand, different electricity price scenarios considering a co...
2011-01-01
Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory
Energy Technology Data Exchange (ETDEWEB)
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment ...
1995-05-01
Fabrication of core demonstration experiments for irradiation in the FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
A major new initiative to develop and irradiate a long-lived, mixed-oxide (MOX) fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the U.S. Department of Energy. The purpose of this new fuel system, called the core demonstration experiment (CDE), is to demonstrate the capability of achieving a 3-yr life in a prototypical, heterogeneous reactor environment under prototypical power and temperature conditions. Ten fuel and six blanket CDEs are establishing the performance characteristics of entire fuel assemblies of wire-wrapped, large-diameter, annular-pellet, advanced MOX fuel pins with the tempered martensitic HT-9 alloy cladding and end caps, HT-9 wire wrap, and an HT-9 duct in a heterogeneous array with the blanket assemblies. The CDE performance characteristics are confirming the basis for design, fabrication, and irradiation of the CDE.
1990-06-10
FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation
International Nuclear Information System (INIS)
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
FFTF (Fast Flux Test Facility) reactor shutdown system reliability reevaluation
Energy Technology Data Exchange (ETDEWEB)
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
1986-07-01
CANDU 6 fuel behaviour in power ramp conditions
International Nuclear Information System (INIS)
The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data obtained from the post-irradiation ...
2009-10-12
International Nuclear Information System (INIS)
Many types of maintenance activities are performed on contaminated (radioactive) machines and components at the Fast Flux Test Facility (FFTF). When personnel dose levels are within permissible limits, maintenance is performed in contaminated work areas or in gloveboxes. Otherwise, maintenance is performed in the Interim Examination and Maintenance (IEM) Cell, a hot cell that is used to perform tasks that require remote operation. Maintenance is often a combination of manual and remote operation. One such operation was the cleaning of the closed loop ex-vessel machine (CLEM) core component grapple (CCG). The CLEM is used to transfer core components in and out of the reactor vessel. The CCG had not been operating properly due to buildups of metallic sodium and sodium compounds on the outside surface and internal moving parts. This paper tells how the CCG was disassembled and cleaned. ...
1990-11-11
Upgraded coal interest group. Quarterly report, July 1, 1995--September 30, 1995
Energy Technology Data Exchange (ETDEWEB)
The objectives of the Upgraded Coal Interest Group (UCIG) are as follows: Review and update the status of various coal upgrading technologies and developments and critically assess the results. Perform engineering screening analyses on various coal upgrading approaches. Perform commercialization analyses that will promote the availability and use of upgraded coal products by quantifying the benefits of using them. Identify market opportunities for introduction of upgraded coals. Perform critical analyses on a variety of coals and technologies in areas important to users but not readily available. Perform critical experiments which will show the differences between technologies.
1995-12-31
This environmental assessment quantifies the water quality-related benefits for Transportation Equipment Cleaning (TEC) facilities based on site-specific analyses of current conditions and the conditions that would be achieved by process changes under proposed BAT (Best Available Technology) and PSES (Pretreatment Standards for Existing Sources) controls. The US Environmental Protection Agency (EPA) estimated instream pollutant concentrations for 157 priority and nonconventional pollutants from three subcategories (barge-chemical and petroleum, rail-chemical, and truck-chemical) of direct and indirect discharges using stream dilution modeling. The potential impacts and benefits to aquatic life are projected by comparing the modeled instream pollutant concentrations to published EPA aquatic life criteria guidance or to toxic effect levels.
1998-05-01
Encoal mild coal gasification project: Commercial plant feasibility study
Energy Technology Data Exchange (ETDEWEB)
In order to determine the viability of any Liquids from Coal (LFC) commercial venture, TEK-KOL and its partner, Mitsubishi Heavy Industries (MHI), have put together a technical and economic feasibility study for a commercial-size LFC Plant located at Zeigler Coal Holding Company`s North Rochelle Mine site. This resulting document, the ENCOAL Mild Coal Gasification Plant: Commercial Plant Feasibility Study, includes basic plant design, capital estimates, market assessment for coproducts, operating cost assessments, and overall financial evaluation for a generic Powder River Basin based plant. This document and format closely resembles a typical Phase II study as assembled by the TEK-KOL Partnership to evaluate potential sites for LFC commercial facilities around the world.
1997-07-01
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, measuring and ...
1991-10-01
Assessing the environmental impacts of resource recovery facilities
Energy Technology Data Exchange (ETDEWEB)
Technologies and practices that recover energy and materials from municipal solid waste present a technically and economically viable alternative to sanitary landfills and other solid waste disposal methods. However, community planners considering resource recovery should be aware of the potential environmental impacts of proposed projects. To assess these impacts, a planner should: identify the most significant types of impacts; establish boundaries beyond which impacts are not significant; characterize the environment as it would exist without the proposed project over the project's lifetime; predict the magnitude, and the distribution over time and space, of potential impacts; and relate the magnitude of predicted impacts to a scale of significance that will allow environmental values to be considered in decision-making. 24 references, 1 table.
1980-03-01
Energy Technology Data Exchange (ETDEWEB)
The International Atomic Energy Agency (IAEA) plans to use the Common Criteria, as the tool for developing graded and measurable evaluation criteria for information technology (IT) in safeguards systems in facilities subject to IAEA inspection. In their draft paper [ITSECSES] the IAEA defines a three-tiered Vulnerability Assessment Level (VAL) scheme. Each increased VAL level (1-3) defines additional and more stringent security and security-related requirements for the system developer, the system evaluator (assessor or authenticator), and for the IAEA. When all parties meet all requirements for a particular VAL level, IAEA has a measurable degree of confidence in the secure and proper operation of an IT system.
2001-12-06
International Nuclear Information System (INIS)
Development of the Conawapa-Winnipeg power transmission complex in Manitoba includes five interrelated transmission and conversion facilities. Environmental and socio-economic assessment work done to date on one component of this system (the upgrading of the Southern Receiver System) is described. This system is composed of a network of high voltage transmission lines and station facilities serving power demand in Winnipeg and southern Manitoba. The upgrading involves three main elements: energizing a second 230 kV ac circuit on an existing tower line running from the proposed Riel Station site to the existing St. Vital Station; constructing a new double-circuit 230 kV tower line on the same existing right-of-way between St. Vital and the Riel site area; and installing an additional transformer and other necessary equipment at St. Vital and other stations affected by the upgrade. The environmental impacts of these projects ...
1992-01-01
BWNT assessment of TRAC/PF1-MOD2
International Nuclear Information System (INIS)
The TRAC/PFI-MOD2 Version 5.3 code was assessed against six FLECHT-SEASET forced reflood tests (31504, 31203, 31302, 31701, 34209, and 31922) and two cylindrical core test facility (CCTF) tests [C1-19 and C2-6]. The objective of this study was to evaluate the clad thermal response predictive capabilities of the code with the newly added reflood model under large-break loss-of-coolant accident (LOCA) conditions in a pressurized water reactor (PWR). The TRAC model for the FLECHT-SEASET test facility was developed from a RELAP5 model. The test section was modeled using a vessel component with 23 axial levels, 1 radial ring, and 1 azimuthal cell. Test inlet and exit conditions were modeled using fill and break components, respectively. The measured lower and upper plenum test conditions were input to the model. The electrically heated rod was modeled using a rod component with 22 axial mesh points. The axial boundary of each ...
1993-11-14
FY05-FY06 Advanced Simulation and Computing Implementation Plan, Volume 2
Energy Technology Data Exchange (ETDEWEB)
The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the safety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program will require the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment ...
2004-07-19
Energy Technology Data Exchange (ETDEWEB)
With regard to polybrominated diphenyl ether (PBDE), there is few scientific knowledge on the emission patterns into the environment and exposure pathways to humans, and basic information is insufficient to consider what measures effective are. For the purpose of promoting risk reduction of target substances more effectively and efficiently, it is desirable to comprehend accurately the causal chain from the target substances utilization to the risk intake, and to evaluate the measures covering the whole applications of target substances. As the existing researches on the PBDE emission inventory, there are EU risk assessment report (European Chemical Bureau 2000, 2002, 2003), Danish EPA (1999), Palm et al.(2002) and Alcock et al. (2003). In addition, emissions of DecaBDE are published in TRI (Toxic Release Inventory) of US EPA. However, the primary information of the previous inventories is often the same and estimations based on the measured values are few. In ...
2004-09-15
Waste Handeling Building Conceptual Study
Energy Technology Data Exchange (ETDEWEB)
The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options ...
2000-11-06
Examination of scaling criteria for nuclear reactor thermal-hydraulic test facilities
International Nuclear Information System (INIS)
Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland College Park. The heat loss ...
1987-01-01
Entombment Using Cementitious Materials: Design Considerations and International Experience
Energy Technology Data Exchange (ETDEWEB)
Cementitious materials have physical and chemical properties that are well suited for the requirements of radioactive waste management. Namely, the materials have low permeability and durability that is consistent with the time frame required for short-lived radionuclides to decay. Furthermore, cementitious materials can provide a long-term chemical environment that substantially reduces the mobility of some long-lived radionuclides of concern for decommissioning (e.g., C-14, Ni-63, Ni-59). Because of these properties, cementitious materials are common in low-level radioactive waste disposal facilities throughout the world and are an attractive option for entombment of nuclear facilities. This paper describes design considerations for cementitious barriers in the context of performance over time frames of a few hundreds of years (directed toward short-lived radionuclides) and time frames of thousands of years (directed ...
2002-08-01
Entombment Using Cementitious Materials: Design Considerations and International Experience
Energy Technology Data Exchange (ETDEWEB)
Cementitious materials have physical and chemical properties that are well suited for the requirements of radioactive waste management. Namely, the materials have low permeability and durability that is consistent with the time frame required for short-lived radionuclides to decay. Furthermore, cementitious materials can provide a long-term chemical environment that substantially reduces the mobility of some long-lived radionuclides of concern for decommissioning (e.g., C-14, Ni-63, Ni-59). Because of these properties, cementitious materials are common in low-level radioactive waste disposal facilities throughout the world and are an attractive option for entombment of nuclear facilities. This paper describes design considerations for cementitious barriers in the context of performance over time frames of a few hundreds of years (directed toward short-lived radionuclides) and time frames of thousands of years (directed ...
2002-05-15
Conversion of the Midland nuclear station
Energy Technology Data Exchange (ETDEWEB)
The authors report how the Midland cogeneration venture (MCV) is repowering the incomplete Midland nuclear plant to operate as a gas-fired combined cycle cogeneration facility. They discuss how their company is responsible for performing engineering, procurement, licensing, construction, start-up, training, and operational assistance for this facility. As shown, twelve gas turbine generator sets supply heat to twelve heat recovery steam generators (HRSGs), which are headered together on the steam side to provide energy to either of two existing steam turbine generators. This combination of equipment enables approximately 1,380 MWe of electrical generation capability, while supplying an average steam flow of 629,000 lbs/hr to an adjacent Dow Chemical Company pant. The MCV facility will also provide 60 MW of electric power to Dow. The authors report how the Midland ccogeneration venture (MCV) is ...
1988-01-01
Review on the status of solid radwaste management in Korean NPPs
International Nuclear Information System (INIS)
To minimize the low and intermediate-level solid radwaste volume, the reduction efforts were persisted in Korean NPPs. As a result, annual average waste volumes were reduced to 194 drums per unit at last year. In this paper we confirmed 250 drums/unit-yr, EPRI URD management goal, and management condition for solid radwaste volume. Also, through the sample assessment of specific Korean NPP opened to the public, we could make sure that the prediction of saturation year for interim storage facility is fully suitable.
2003-10-01
Energy Technology Data Exchange (ETDEWEB)
The overall purpose of this research was to evaluate the independent and interactive effects of elevated levels of CO{sub 2} and O{sub 3} on tree leaf litter quality and decomposition. This research was conducted at the Aspen FACE (Free Air CO{sub 2} Enrichment) facility near Rhinelander, Wisconsin. This research comprised one facet of a larger project assessing how CO{sub 2} and O{sub 3} pollutants will alter carbon sequestration and nutrient cycling in north temperate forest ecosystems.
2004-08-03
Energy Technology Data Exchange (ETDEWEB)
A collection of 14 papers from a June 1981 seminar assess the costs of damage caused by water pollution. The seminar focused on the economic rather than the legal standpoint by evaluating the cost of the clean-up operations themselves and other costs, such as direct or indirect economic losses, and converting into money terms the damage to the environment, the loss of recreational facilities, and biomass losses. The papers are grouped into four sections which look at the scale of risk, the clean-up costs for specific oil spills, other costs inflicted on coastal zones, and legal aspects of compensation. Separate abstracts were prepared for each of the 16 papers selected for the Energy Data Base.
1982-01-01
Organization and management activities in the nuclear power industry
International Nuclear Information System (INIS)
The purpose of organization and management development activities in the commercial nuclear power industry is to foster high levels of power plant performance and safety through improved human performance. The NRC has been working to develop assessment tools to assay the effects of organizational factors on plant safety. The utility industry has been working on initiatives targeting individual accountability, the improvement of plant performance and the elimination of the items identified through the NRC assessment process. Organization and management activities do not focus on industry organizational charts, but on the personnel processes and dimensions (factors) that affect safety and economic performance. As individual terms these activities are often combined and referred to as organizational factors. As an area of study, organizational factors has become ...
1994-04-01
The Vortec Cyclone Melting System (CMS) facility; to be located at the U.S. Department of Energy (DOE) Paducah Gaseous Diffusion Plant, is designed to treat soil contaminated with low levels of heavy metals and radioactive elements, as well as organic waste. The primary components of Vortec`s CMS are a counter rotating vortex (CRV) reactor and cyclone melter. In the CMS process, granular glass forming ingredients and other feedstocks are introduced into the CRV reactor where the intense CRV mixing allows the mixture to achieve a stable reaction and rapid heating of the feedstock materials. Organic contaminants in the feedstock are effectively oxidized, and the inert inorganic solids are melted. The University of North Dakota Energy {ampersand} Environmental Research Center (EERC) has been contacted to help in the development of sampling plans and to conduct the sampling at the facility. This document is written in a format that assumes that the ...
1997-12-31
This report presents the results of Run 261 performed at the Advanced Coal Liquefaction R & D Facility in Wilsonville, Alabama. The run started on January 12, 1991 and continued until May 31, 1991, operating in the Close-Coupled Integrated Two-Stage Liquefaction mode processing Illinois No. 6 seam bituminous coal (from Burning star No. 2 mine). In the first part of Run 261, a new bimodal catalyst, EXP-AO-60, was tested for its performance and attrition characteristics in the catalytic/catalytic mode of the CC-ITSL process. The main objective of this part of the run was to obtain good process performance in the low/high temperature mode of operation along with well-defined distillation product end boiling points. In the second part of Run 261, Criterion (Shell) 324 catalyst was tested. The objective of this test was to evaluate the operational stability and catalyst and process ...
1992-09-01
CFCC radiant burner assessment. Final report, April 1, 1992--July 31, 1994
Energy Technology Data Exchange (ETDEWEB)
The objective of this work was to identify methods of improving the performance of gas-fired radiant burners through the use of Continuous Fiber Ceramic Composites (CFCCs). Methods have been identified to improve the price and performance characteristics of the porous surface burner. Results are described.
1994-11-01
Performance of hydrous titanium oxide-supported catalysts in coal-liquids upgrading
Experimental tests were performed in a continuous-flow hydrotreating unit at Pittsburgh Energy Technology Center to evaluate the performance of hydrous titanium-oxide supported (HTO) catalysts as hydrotreating catalysts for use in two-stage coal liquiefaction. Catalysts containing either a combination of CO, Ni, and Mo as the active metal components or Pd as the active metal componet were tested with representative hydrotreater feed stocks from the Wilsonville Advanced Coal Liquefaction Research and Development Facility. Catalyst performance evaluation was based on desulfurization and denitrogenation activity, the conversion of cyclohexane-insolbule material, and hydrogenation activity during 100-hour reactor runs. Results indicated that the HTO catalysts were comparable to a commercial Ni/Mo-alumina supported catalyst in the areas evaluated. 11 refs., 1 fig., 6 tabs.
1988-01-01
Progress at LAMPF. Progress report, January-December 1985
Energy Technology Data Exchange (ETDEWEB)
Research performed at LAMPF during 1985 is reported in the areas of: nuclear and particle physics; atomic and molecular physics; materials science; radiation-effects studies; biomedical research and instrumentation; nuclear chemistry; radioisotope production; and physics theory. Also reported are the status of LAMPF-II, facility development work, and accelerator operations. (LEW)
1986-05-01
Pollution control instrumentation for oil and effluents
Energy Technology Data Exchange (ETDEWEB)
This book provides discusses recent developments in oil pollution control instrumentation. Some of the topics covered are as follows: 1. Technical requirements of the IMCO International Performance and Test Specification A393x concerning oil content meters; and 2. Oil in water detection; and 3. Methods for the disposal of recovered oil and oily sludge; and 4. Oil content monitoring at ballast water treatment facilities and offshore production platforms.
1986-01-01
Leveraging limited research and development (R&D) resources in the public sector
Energy Technology Data Exchange (ETDEWEB)
Mission-directed public-sector research facilities are experiencing increasingly severe budget environments while seeing expanding missions and responsibilities. In an effort to identify research leveraging methodologies an information search was conducted in conjunction with some efforts to find the proper links to systems engineering fundamentals. The result is an initial model for use in a pre-concept/phase-1 engineering design organization, with a goal of improving the organizations performance.
1996-12-01
KEROGEN OIL VALUE ENHANCEMENT RESEARCH
Energy Technology Data Exchange (ETDEWEB)
Task 13 (a) was approved on December 21, 2001. Minimal work was performed for the quarter during the approval process. Laboratory and equipment facilities have been maintained in anticipation of the work to be done. The PI communicated with DOE and Estonia researchers during this period, providing advice and direction for the startup of the Estonia research, and preparing a Draft Teaming Agreement. The PI participated in an industrial liaison meeting with DOE personnel. This meeting is expected to lead to formal cooperation between industry and government.
2002-01-11
Irradiation data for the MFA-1 and MFA-2 tests in the FFTF
Energy Technology Data Exchange (ETDEWEB)
This report provides key information on the irradiation environment of the MONJU fuel tests MFA-1 and MFA-2 in the Fast Flux Test Facility (FFTF). This information includes the fission powers, neutron fluxes, sodium temperatures and sodium flow rates in MFA-I, MFA-2 and adjacent assemblies. It also includes MFA-1 and MFA-2 compositions as a function of exposure. The work was performed at the request of Power Reactor and Nuclear Fuels Corporation (PNC) of Japan.
1997-04-24
Hot Particles Research for Nuclear Power Plant in Wolsung
Energy Technology Data Exchange (ETDEWEB)
The evaluation of the hazard posed to the skin by very small radioactive sources (diameter < 1mm) has become popularly known as the 'hot particle' problem in European and American nuclear reactor facilities. In this study, research to detect hot particle was performed in Wolsung Nuclear power plant (NPP) in Korea.
2007-10-15
Hot Particles Research for Nuclear Power Plant in Wolsung
International Nuclear Information System (INIS)
The evaluation of the hazard posed to the skin by very small radioactive sources (diameter < 1mm) has become popularly known as the 'hot particle' problem in European and American nuclear reactor facilities. In this study, research to detect hot particle was performed in Wolsung Nuclear power plant (NPP) in Korea.
2007-10-01
Energy analysis for Fort McNair, Marshall Hall
Marshall Hall was selected by the US Army Corps of Engineers to participate in the Energy Efficiency Analysis Program. The objective of this program is to assist military installations in identifying energy usage and cost saving projects at their facilities and possibly provide funding for projects. Entech Engineering, Inc. was selected to perform this study.
1995-08-01
Thermal performance and design of a solid particle cavity receiver
Energy Technology Data Exchange (ETDEWEB)
A model for energy transport in a solid particle cavity receiver is developed and applied to the design and analysis of a receiver for the Central Receiver Test Facility (CRTF), Albuquerque, New Mexico. The model gives thermal performance results - including particle temperatures, cavity efficiencies, and wall temperatures - which directly affect the economic and technical feasibility of a solid particle receiver. In addition, design criteria relevant to the configuration of a solid particle cavity receiver are developed. Results for CRTF indicate that at design conditions particle temperatures will exceed 1200/sup 0/K with cavity efficiencies on the order of 75%.
1985-04-01
High power evaluation of X-band high power loads
Several types of X-band high power loads developed for several tens of MW range were designed, fabricated and used for high power tests at X-band facility of KEK. Some of them have been used for many years and few units showed possible deterioration of RF performance. Recently revised-design loads were made by CERN and the high power evaluation was performed at KEK. In this paper, the main requirements are recalled, together with the design features. The high power test results are analysed and presented
2010-01-01
Development of the SRS environmental counting laboratory gamma spectroscopy system
International Nuclear Information System (INIS)
The Savannah River Site (SRS), one of several U.S. Department of Energy (DOE) facilities, produces nuclear materials for national defense and for other government and civilian uses. SRS ceased production of defense materials in 1988, and the site's main activities now involve waste management and environmental restoration. These programs have generated extensive effluent monitoring and environmental surveillance programs for the Environmental Monitoring Section (EMS), which performs #approx#105,000 radiological analyses on 30,000 samples a year. Gamma spectroscopy is performed on an estimated 10,000 samples annually. This report describes a program to develop and improve the EMS system.
1996-06-16
Combustion performance of Coal Valley coal in a pilot-scale utility boiler. Report No. ERL 87-18(CF)
Energy Technology Data Exchange (ETDEWEB)
Combustion performance trials were conducted on a commercial sample of Coal Valley coal from the Coalspur coalfield in the foothills region of Alberta. The project included an analytical investigation of the coal and coal ash properties as well as combustion studies in the CCRL pilot-scale, pulverized coal-fired boiler, under conditions representative of those in large steam boilers. This report gives the objectives of the project, the analyses of the coals, and describes the facilities and operational procedures. An evaluation of the experimental results and the conclusions are presented.
1987-01-01
CLEO: a knowledge-based refueling assistant at FFTF
International Nuclear Information System (INIS)
A computer software system, CLEO, is used to assist in the planning and performance of the reactor refueling operations at the Fast Flux Test Facility (FFTF). It is a recently developed application of artificial intelligence software with both expert systems and automated reasoning aspects. CLEO, an acronym for Cloned LEO, is a logic-based computer program written in Pascal. It imitates the processes that the refueling expert for FFTF performs in organizing the refueling of FFTF. The computer assistant seeks to organize the sequence of core component movements according to the rules and logic used by the expert. In this form, CLEO has aspects that tie it to both the expert systems and automated reasoning areas within the artificial intelligence field.
1985-11-10
University of Central Lancashire - Facilities
...specialised laboratories for pharmaceutics, tissue culture and molecular biology Excellent Laboratory Facilities Tissue Culture Facilities Molecular Biology Laboratory ...
Energy Technology Data Exchange (ETDEWEB)
A Lawrence Livermore National Laboratory (LLNL) Management Pre-Start Review (MPR) Team was formed to independently verify the operational readiness of Building 368 (B368) Biosafety Level III (BSL-3) Facility to conduct research with biological pathogens and toxins including those considered Select Agents. Review objectives and criteria were developed from the DOE/NNSA and LLNL requirements. These were provided in the Implementation Plan for the Biosafety Level III (BSL-3) Facility Management Pre-Start Review (BSL-3 MPR) at Lawrence Livermore National Laboratory that was reviewed and approved by DOE/NNSA-LSO. The formal part of the LLNL MPR for the BSL-3 Facility was begun in August of 2005 but work on the MPR was stopped in October of 2005 due to the need for LLNL to reassess organizational and operational controls and respond to Centers for Disease Control and Prevention inquiries related to a shipping incident involving ...
2006-07-25
Requirements for modeling and simulation of space RSTA assets
The Department of Defense (DoD) has long depended on military support functions enabled by space reconnaissance, surveillance, and target acquisition (RSTA) assets. Future generation satellite capabilities will further push technologies in space - if the right technologies are deployed in the right numbers and with the right payloads. Modeling and simulation play major parts in developing and deploying such assets: 1) system and operational requirements determination, and 2) assessment of military utility of such assets. Each area is critical in a system"s life cycle. Requirements determination cuts across the issues of doctrine, organizations, training, materiel, leader development, personnel, and facilities (DOTMLPF). Military utility assessments are necessary to explore and quantify the military worth/benefit of space RSTA assets to operational commanders. Each of these areas requires relevant modeling/simulation tools ...
2004-09-01
International Nuclear Information System (INIS)
The objective of this report was to evaluate four possible alternative methods of preparing and packaging spent fuel assemblies for geologic disposal against the Reference Process of unmodified spent fuel. The four alternative processes were: (1) End fitting removal, (2) Fission gas venting and resealing, (3) Fuel bundle disassembly and close packing of fuel pins, and (4) Fuel shearing and immobilization. Systems analysis was used to develop a basis of comparison of the alternatives. Conceptual processes and facility layouts were devised for each of the alternatives, based on technology deemed feasible for the purpose. Assessments were made of 15 principal attributes from the technical, operational, safety/risk, and economic considerations related to each of the alternatives, including both the surface packaging and underground repository operations. Specific attributes of the alternative processes were evaluated by assigning a number for each ...
A framework for assessing relative risks associated with multiple stressors in Port Valdez, Alaska
Energy Technology Data Exchange (ETDEWEB)
The purpose of this assessment is to develop a versatile process that will provide a mechanism for evaluating both present and future risks to this environment. Much of the regulatory and environmental interest in the port has centered around a Ballast Water Treatment facility that treats and discharges up to 30 mgd of oily ballast water brought in by crude oil tankers. However, six point discharges and other potential sources of pollution exist in the area. The authors have delineated eleven subareas in the port in order to identify the potential anthropogenic stressors, as well as the receptors that could be exposed to these stressors. Potential effects were then characterized for each exposure. Each component is ranked and integrated, resulting in a relative risk estimate in each subarea. Both the discernible risks, based on available data, and the data gaps are presented. Uncertainty is expressed as a range of high and low risk associated ...
1995-12-31
Spent Fuel Background Report Volume I
Energy Technology Data Exchange (ETDEWEB)
This report is an overview of current spent nuclear fuel management in the DOE complex. Sources of information include published literature, internal DOE documents, interviews with site personnel, and information provided by individual sites. Much of the specific information on facilities and fuels was provided by the DOE sites in response to the questionnaire for data for spent fuels and facilities data bases. This information is as accurate as is currently available, but is subject to revision pending results of further data calls. Spent fuel is broadly classified into three categories: (a) production fuels, (b) special fuels, and (c) naval fuels. Production fuels, comprising about 80% of the total inventory, are those used at Hanford and Savannah River to produce nuclear materials for defense. Special fuels are those used in a wide variety of research, development, and testing activities. Special fuels include fuel from DOE and commercial ...
1994-03-01
Large sample NAA facility at GRR-1 research reactor: Design and applications
International Nuclear Information System (INIS)
Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of large sample analysis of ...
2003-06-09
Energy Technology Data Exchange (ETDEWEB)
Since enterprises operating offices and facilities at geographically distributed sites have been establishing an intranet for inter-office communication at the management level, the idea of integrating another intranet for multi-site technological facility management comes naturally. The Aachen-based technology enterprise Eurem for this purpose developed a Network and Security concept with solutions that can be customized for linking a variety of computerized control and monitoring systems. The package includes a modular substation named modUS, which is open to the field side as well as to the management side, is capable of efficiently and reliably performing the facility management functions by way of remote controlling via intranets. (orig./CB) [Deutsch] Nachdem in den Unternehmen mit verteilten Liegenschaften die unterschiedlichsten Buerokommunikationssysteme ueber eigene Netzwerke verbunden werden, ...
1999-02-08
This report has been prepared in conjunction with an environmental baseline study for a commercial coal conversion facility being conducted by Ashland Synthetic Fuels, Inc. (ASFI) and Airco Energy Company (AECO). This report represents a cultural resource assessment for the proposed plant site and two potential solid waste disposal areas. This assessment presents data collected by Dames and Moore during a recent archaeological reconnaissance of the unsurveyed southeastern portion of the proposed plant site and two potential solid waste disposal areas. Also, results of two previous surveys on the northern and southwestern portion of the plant site for American Smelting and Refining Company (ASARCO) and Kentucky Utilities are included. The Dames and Moore survey of the southeastern portion of the plant site identified one archaeological site, three standing structures and one historic cemetery. In addition 47 archaeological ...
Role of CT in the assessment of the volume to be irradiated in bone metastases
International Nuclear Information System (INIS)
In the Department of Radiology of Catholic University S. Cuore in Rome, a review was made of 342 CT examinations with a view towards optimizing the therapeutic planning in patients affected by bone metastases. All patients were submitted to radiological positioning and then to CT evaluation in order to assess the volume to be treated. In 224 cases it was not necessary to perform wide CT examination (3-5 standard tomograms being enough, 2 of which at the superior and inferior margins of the planned field). In the second group of 118 patients it was necessary to perform CT (serial axial scans) - increasing by 1-1.5 cm - up to the superior and inferior margins of the lesion. The existence of 2 types of lesions was confirmed: those involving mainly bony structures and those infiltrating the soft tissues. CT evaluation allowed the definition of the target volume to the real extension of the lesion in 14% of the whole of cases, ...
1988-01-01
International Nuclear Information System (INIS)
The Rocky Flats Environmental Technology Site (RFETS) has historically released radionuclide chemicals of potential concern into the surrounding environment. The off-site environment was evaluated for Pu"2"3"9"/"2"4"0 and Am"2"4"1 occurrence. An evaluation of exposure and effects to the aquatic ecology within off-site areas including: Standley Lake, Great Western Reservoir, Mower Reservoir and portions of Big Dry Creek, Walnut Creek, and Woman Creek was performed for the completion of an Ecological Risk Assessment. Collocated sampling activities were performed for surface water, sediment, benthic macroinvertebrates and fish. Results of the analytical data were used to assess ongoing exposure and effects. Data collected to determine effects (chemical content of fish tissue, diversity and density of macroinvertebrate populations) provided some of the necessary information needed to evaluate risk. However, ...
1995-11-05
Development of a probabilistic timing model for the ingestion of tap water.
Energy Technology Data Exchange (ETDEWEB)
A contamination event in a water distribution system can result in adverse health impacts to individuals consuming contaminated water from the system. Assessing impacts to such consumers requires accounting for the timing of exposures of individuals to tap-water contaminants that have time-varying concentrations. Here we present a probabilistic model for the timing of ingestion of tap water that we developed for use in the U.S. Environmental Protection Agency's Threat Ensemble Vulnerability Assessment and Sensor Placement Tool, which is designed to perform consequence assessments for contamination events in water distribution systems. We also present a statistical analysis of the timing of ingestion activity using data collected by the American Time Use Survey. The results of the analysis provide the basis for our model, which accounts for individual variability in ingestion timing and provides ...
2009-01-01
The NIST/NRL free-electron laser facility
International Nuclear Information System (INIS)
A free-electron laser (FEL) user facility is discussed. The FEL, which will be operated as an oscillator, will be driven by the electron beam of the racetrack microtron (RTM) that is nearing completion. Variation of the electron kinetic energy from 17 MeV to 185 MeV will permit the FEL wavelength to be tuned from 200 nm to 10 #mu#m. Performance will be enhanced by the high brightness, low energy spread, and continuous pulse nature of the RTM electron beam. The authors are designing a new injector to increase the peak current of the RTM. A 3.6-m undulator is under construction, and the 9-m optical cavity is under design. The FEL will emit a continuous train of 3-ps pulses at 66 MHz with an average power of 10--200 W, depending on the wavelength, and a peak power of up to several hundred kW. An experimental area is being prepared with up to five stations for research using the FEL beam.
1989-04-24
Stability and disturbance of large dc superconducting magnets
Energy Technology Data Exchange (ETDEWEB)
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.
1981-11-11
Removal of scattered thermal neutrons using antiscatter grid
International Nuclear Information System (INIS)
One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.
2006-12-01
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Reduction of statistic error in Mihalczo subcriticality measurement
Energy Technology Data Exchange (ETDEWEB)
The theoretical formula for the statistical error estimation in Mihalczo method was derived, and the dependence of the error were investigated on the facility to be measured and on the parameter in the data analysis. The formula was derived based on the reactor noise theory and the error theory for the frequency analysis, and found that the error depends on such parameters as the prompt neutron decay constant, detector efficiencies, and the frequency bandwidth. Statistical errors estimated with the formula was compared with experimental values and verified to be reasonable. Through parameter surveys, it is found that there is an optimum combination of the parameters to reduce the magnitude of the errors. In the experiment performed in DCA subcriticality measurement facility, it is estimated experimentally that the measurement requires 20 minutes to obtain the statistic error of 1% for the keff 0.9. According to the error ...
1998-08-01
Radiological operating experience at FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility has been in operation for approximately five years, including about one thousand days of full power operation of the Fast Test Reactor. During that time the collective dose equivalents received by operating personnel have been about two orders of magnitude lower than those typically received at commercial light water reactors. No major contamination problems have been encountered in operating and maintaining the plant, and release of radioactive gas to the environment has been minimal and well below acceptable limits. All shields have performed satisfactorily. Experience to date indicates an apparent radiological superiority of liquid metal reactor systems over current light water plants.
1987-04-22
Neutron-induced fission cross-section of {sup 233}U in the energy range 0.5<E{sub n}< 20 MeV
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
2011-01-15
Energy Technology Data Exchange (ETDEWEB)
The Hazardous Materials Control Module (HMC) is one module of four for the Industrial Health component. The HMC module was designed to inform employees of health and safety hazards in the workplace and to track the movement of hazardous materials through the facility. The module performs these functions by maintaining health and safety data on hazardous materials used in the facility, and by tracking who requests information about any hazardous materials. The HMC module gets its information from two sources. The first one is the Hazardous Materials Information System (HMIS), this is a national system that is used by the Department of Defense. It is loaded on to the system via tapes that contain all safety, health and transportation information about a particular product. The second is Material Safety Data Sheets (MSDS) that are procured by a particular site. This information is manually entered into their own personal ...
1987-01-16
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.
1987-09-13
Fabrication of core demonstration experiments for irradiation in FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
A major initiative to develop and irradiate a long-life, mixed-oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the US Department of Energy. The FFTF, shown in Figures 1 and 2, is a 400 megawatt thermal, fast liquid metal reactor that tests liquid metal, space and fusion fuels and materials. The new fuel system, called the Core Demonstration Experiment (CDE) demonstrates the capability of achieving a three- to four-year life in a prototypic heterogeneous reactor environment under prototypic power and temperature conditions. This fuel system will greatly increase fuel performance and lifetime from the current standard FFTF driver fuel. New design features, fabrication development, CDE assembly fabrication, and irradiation status have been described.
1990-06-10
Mercury flow experiments. 3. Simulation test plan under abnormal condition
Energy Technology Data Exchange (ETDEWEB)
Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, transient behaviors of ...
2002-02-01
International Nuclear Information System (INIS)
The US Department of Energy has provided support to four universities and the Oak Ridge National Laboratory in order to pursue research leading to the development and deployment of an advanced robotic system capable of performing tasks that are hazardous to humans, that generate significant occupational radiation exposure, and/or whose execution times can be reduced if performed by an automated system. The goal is to develop a generation of advanced robotic systems capable of performing surveillance, maintenance, and repair tasks in nuclear facilities and other hazardous environments. This goal will be achieved through a team effort among the Universities of Florida, Michigan, Tennessee, Texas, and the Oak Ridge National Laboratory, and their industrial partners, Combustion Engineering, Martin Marietta Baltimore Aerospace, Odetics, Remotec, and Telerobotics International. Each of the universities and ...
Transient performance of FFTF [Fast Flux Test Facility] reference fuel
International Nuclear Information System (INIS)
Fourteen irradiated Fast Flux Test Facility (FFTF) fuel pins were subjected to representative overpower transients in six flowing sodium loop experiments conducted in the TREAT reactor. The transient tests were extended to substantial overpower levels well beyond protected levels, with some tests intentionally run to failure to identify failure thresholds and characteristics. Test variables included transient ramp rate (5, 50, and 100 cents/s) and burnup (2 to 58 MWd/kg). Performance limits and failure characteristics were identified, and cladding strain and fuel melting data were obtained for development and verification of transient analysis codes. The test results demonstrated that FFTF Reference fuel pins are capable of surviving overpower levels well beyond the FFTF secondary Plant Protection System (PPS) trip limit of 1.25 times normal rated power. Based on analytical evaluations to interpolate and extrapolate test results to the full ...
1986-09-07
Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research
Energy Technology Data Exchange (ETDEWEB)
JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, ...
2001-03-01
Installation of the natural gas network at Paray-Vieille Poste, France
Energy Technology Data Exchange (ETDEWEB)
This paper summarizes the investigation of horizontal direction drilling and the subsequent experimental installation of a natural gas network in a suburb of Paris, France. Three aspects of drilling were studied prior to implementation: (1) reliability of the technique and quality of pipelaying to ensure long-term supply main operation; (2) ability to assess the successfulness of the work by assessing preliminary conditions; and (3) economonic viability. Measurement of tensile stress on polyethylene pipe during pulling and comparative accelerated aging tests on scratched pipe were performed. In the implementation phase, 300 meters of pipe were laid daily, by using three machines simultaneously, at a cost comparable to that of conventional techniques.
1996-08-01
A framework for the establishment of organizational risk indicators
International Nuclear Information System (INIS)
Organizational risk indicators are proposed as a tool for risk control during operation of offshore installations, as a complement to QRA-based indicators. An organizational factor framework is developed based on a review of existing organizational factor frameworks, research on safety performance indicators, and previous work on QRA-based indicators. The results comprise a qualitative organizational model, proposed organizational risk indicators, and a quantification methodology for assessing the impact of the organization on risk. The risk indicators, when validated, will aid in a frequent control of the risk in the periods between the updating of the quantitative risk assessments.
2001-11-01
Energy Technology Data Exchange (ETDEWEB)
Oil and gas resources in the offshore areas of the US constitute a significant portion of US recoverable hydrocarbon resources. The exploration, development and production of these offshore resources in California, however, could have significant air quality implications for coastal air basins. This study was developed to address a problem that frequently arises with offshore air quality assessments. Typically, such assessments are performed for a specific activity scenario (e.g., a Federal OCS Lease Sale involving a projected number of drilling rigs, platforms, pipelines, etc.) and assume a projected (but uncertain) level of recoverable oil and gas resources. This study enables interested parties to estimate air emissions and impacts for a wide range of OCS-related development scenarios. The modular emission calculation procedure and the generic impact assessment provide for maximum flexibility in ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL ...
2010-11-15
International Nuclear Information System (INIS)
This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL ...
2010-11-01
PROBABILISTIC SAFETY ASSESSMENT OF OPERATIONAL ACCIDENTS AT THE WASTE ISOLATION PILOT PLANT
Energy Technology Data Exchange (ETDEWEB)
This report presents a probabilistic safety assessment of radioactive doses as consequences from accident scenarios to complement the deterministic assessment presented in the Waste Isolation Pilot Plant (WIPP) Safety Analysis Report (SAR). The International Council of Radiation Protection (ICRP) recommends both assessments be conducted to ensure that ''an adequate level of safety has been achieved and that no major contributors to risk are overlooked'' (ICRP 1993). To that end, the probabilistic assessment for the WIPP accident scenarios addresses the wide range of assumptions, e.g. the range of values representing the radioactive source of an accident, that could possibly have been overlooked by the SAR. Routine releases of radionuclides from the WIPP repository to the environment during the waste emplacement operations are expected to be essentially zero. In ...
2000-09-01
Workshop on rock mechanics issues in repository design and performance assessment
Energy Technology Data Exchange (ETDEWEB)
The Center for Nuclear Waste Regulatory Analyses organized and hosted a workshop on ``Rock Mechanics Issues in Repository Design and Performance Assessment`` on behalf its sponsor the U.S. Nuclear Regulatory Commission (NRC). This workshop was held on September 19- 20, 1994 at the Holiday Inn Crowne Plaza, Rockville, Maryland. The objectives of the workshop were to stimulate exchange of technical information among parties actively investigating rock mechanics issues relevant to the proposed high-level waste repository at Yucca Mountain and identify/confirm rock mechanics issues important to repository design and performance assessment The workshop contained three technical sessions and two panel discussions. The participants included technical and research staffs representing the NRC and the Department of Energy and their contractors, as well as researchers from the academic, commercial, and ...
1996-04-01
Lightning performance assessment of Hellenic high voltage transmission lines
Energy Technology Data Exchange (ETDEWEB)
A methodology for assessing the lightning performance of Hellenic high voltage transmission lines has been developed. Its main advantage is that the analysed transmission line is divided into regions and the analysis is conducted separately for each one region, taking into account the individual characteristics, which exist in each one of them. The developed approach intends to offer more accuracy in the assessment of lightning performance of Hellenic high voltage transmission lines and of similar lines, where they run at the same time through a plain region, a coastline and/or a mountainous region. The aims of the paper are to describe in detail the proposed methodology and to present results obtained by its application on operating Hellenic transmission lines of 150 and 400 kV. The computed results are compared with the results produced by another software tool published in the technical literature ...
2008-04-15
Energy Technology Data Exchange (ETDEWEB)
Ford, Bacon, Davis Utah Inc. has reevaluated the Spook site in order to revise the December 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings 48 mi northeast of Casper, in Converse County, Wyoming. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 187,000 tons of tailings at the Spook site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.
1981-10-01
Maternal Marital Status and Birth Outcomes: A Systematic Review and Meta-Analyses
British Library Electronic Table of Contents (United Kingdom)
Systematically review risks of an infant being born with low birth weight (LBW), preterm birth (PTB) or small for gestational age (SGA) among married and unmarried women. Medline, Embase, CINAHL, and bibliographies of identified articles were searched for English language studies. Studies reporting birth outcomes of married and unmarried (single and cohabitant) were included. Two reviewers independently collected data and assessed the quality of the studies for biases in sample selection, exposure assessment, confounder, analytical, outcome assessments, and attrition. Meta-analyses were performed using random effect model for both unadjusted and adjusted data and odds ratio (OR), and 95% confidence interval (CI) were calculated. Twenty-one studies of low to moderate risk of bias were inclu...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Fires and explosions have been identified as major potential hazards for Oil and Gas Floating Production Storage Offloading (FPSO) installations and pose risk to personnel, assets, and the environment. Current fire and explosion assessment (FEA) tools require physical effect modeling software and follows standards from API, ISO, and engineering practices. However, the tools are not specific to any particular system such as an FPSO, and do not provide comprehensive guidance for safety engineers to perform FEA. This paper discusses the development of a screening and comparison tool for FEA on FPSOs and the incorporation of an expert system into the tool. The results are computerized using MS Excel/VBA to provide a structured and comprehensive assessment on each equipment and module handling ...
2009-01-01
Engineering assessment of inactive uranium mill tailings, Tuba City site, Tuba City, Arizona
Energy Technology Data Exchange (ETDEWEB)
Ford, Bacon and Davis Utah Inc. has reevaluated the Tuba City site in order to revise the March 1977 engineering assessment of the problems resulting from the existence of radioactive uranium mill tailings at Tuba City, Arizona. This engineering assessment has included the preparation of topographic maps, the performance of core drillings and radiometric measurements sufficient to determine areas and volumes of tailings and radiation exposures of individuals and nearby populations, the investigations of site hydrology and meteorology, and the evaluation and costing of alternative corrective actions. Radon gas released from the 0.8 million tons of tailings at the Tuba City site constitutes the most significant environmental impact, although windblown tailings and external gamma radiation also are factors.
1981-09-01
EMS and process of identification and evaluation of environmental aspects: a proposal methodology
International Nuclear Information System (INIS)
The Environmental Management System (EMS) is an instrument to manage the interaction between the organization and the environment. The scope od EMS is to reduce the environmental impact and to achieve improvements in overall performances. In particular, the focus point of EMS implementation is the method for identifying and assessing significant environmental aspects. The results of the literature and regulation reviews (Perotto 2006) have shown that rigourous repeatable and transparent methodologies do not exist. This paper presents a proposal method for identifying and assessing significant environmental aspects, that has all three of these important characteristics. In particular, the proposal methodology for assessing aspects is based on some criteria that are combined in a specific algorithm. It is important to specify that to make a correct application of the method a preliminary rigorous approach ...
2006-05-01
SP-100 fuel pin performance: Results from irradiation testing
Energy Technology Data Exchange (ETDEWEB)
A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pin are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.
1993-09-01
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE) has been developing a nuclear waste disposal facility, the Waste Isolation Pilot Plant (WIPP), located approximately 42 km east of Carlsbad, New Mexico. The WIPP is designed to demonstrate the safe disposal of transuranic wastes produced by the defense nuclear-weapons program. Pefiormance assessment analyses (U.S. DOE, 1996) indicate that human intrusion by inadvertent and intermittent drilling for resources provide the only credible mechanisms for significant releases of radionuclides horn the disposal system. These releases may occur by five mechanisms: (1) cuttings, (2) cavings, (3) spallings, (4) direct brine releases, and (5) long- term brine releases. The first four mechanisms could result in immediate release of contaminant to the accessible environment. For the last mechanisq migration pathways through the permeable layers of rock above the Salado are important, and major emphasis is placed on the ...
1998-09-01
Development of fission Mo-99 production technology
Energy Technology Data Exchange (ETDEWEB)
This R and D project is planed to supply domestic demands of Mo-99 through fission route, and consequently this project will be expected to rise up utilization of HANARO and KAERI's capability for marketing extension into domestic and oversea radiopharmaceutical market. HEU and LEU target types are decided and designed for fission Mo-99 production in domestic. Experimental study of target fabrication technology was performed and developed processing equipments. And conceptual design of target loading/unloading in/from HANARO device are performed. Tracer test of Mo-99 separation and purification process was performed, test results reach to Mo-99 recovery yield above 80% and decontamination factor above 1600. Combined Mo-99 separation and purification process was decided for hot test scheduled from next year, and performance test was performed. Conceptual design for ...
2001-05-01
Insights from Guideline for Performance of Internal Flooding Probabilistic Risk Assessment (IFPRA)
Energy Technology Data Exchange (ETDEWEB)
An internal flooding (IF) risk assessment refers to the quantitative probabilistic safety assessment (PSA) treatment of flooding as a result of pipe and tank breaks inside the plants, as well as from other recognized flood sources. The industry consensus standard for Internal Events Probabilistic Risk Assessment (ASME-RA-Sb-2005) includes high-level and supporting technical requirements for developing internal flooding probabilistic risk assessment (IFPRA). This industry standard is endorsed in Regulatory Guide 1.200, Revision 1 as an acceptable approach for addressing the risk contribution from IF events for risk informed applications that require U.S. Nuclear Regulatory commission (NRC) approval. In 2006, EPRI published a draft report for IFPRA that addresses the requirements of the ASME PRA consensus standard and have made efforts to refine and update the final EPRI IFPRA guideline. Westinghouse has ...
2009-10-15
The Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama
The investigation of various Two-Stage Liquefaction (TSL) process configurations was conducted at the Wilsonville Advanced Coal Liquefaction R D Facility between July 1982 and September 1986. The facility combines three process units. There are the liquefaction unit, either thermal (TLU) or catalytic, for the dissolution of coal, the Critical Solvent Deashing unit (CSD) for the separation of ash and undissolved coal, and a catalytic hydrogenation unit (HTR) for product upgrading and recycle process solvent replenishment. The various TSL process configurations were created by changing the process sequence of these three units and by recycling hydrotreated solvents between the units. This report presents a description of the TSL configurations investigated and an analysis of the operating and performance data from the period of study. Illinois No. 6 Burning Star Mine coal Wyodak Clovis Point Mine coal were processed. ...
1990-05-01
One-piece removal of JRR-3 reactor block
Energy Technology Data Exchange (ETDEWEB)
JRR-3 is a research reactor of 10 MWt output, which attained the criticality in 1962. All the design, manufacture, installation and others of this reactor were carried out by Japanese technologies, except the fuel and heavy water as the moderator and coolant, therefore it is nicknamed Home-made No.1 Reactor. Recently, due to the change in the state of utilizing research reactors and the rise of quality in the utilization, JRR-3 has become to be unable to meet sufficiently the needs of users. The plan of reconstructing the JRR-3 was considered under such situation, and in order to reuse the reactor building, the reactor proper is removed, and an entirely new, high performance, versatile reactor is to be constructed. In this paper, as to the removal works of the JRR-3 reactor proper, the method of execution, design, the execution of works and so on are outlined. The removal works of the reactor facilities were started in February, 1986. The ...
1987-07-01
New developments in dry spent fuel storage
International Nuclear Information System (INIS)
As shown in various new examples, HABOG facility (Netherlands), CERNAVODA (Candu - Romania), KOZLODUY (WWER - Bulgaria), CHERNOBYL ( RMBK - Ukraine), MAYAK (Spent Fuel from submarine and Icebreakers - Russia), recent studies allow to confirm the flexibility and performances of the CASCAD system proposed by SGN, both in safety and operability, for the dry storage of main kinds of spent fuel. The main features are: A multiple containment barrier system: as required by international regulation, 2 independent barriers are provided (tight canister and storage pit); Passive cooling, while the Fuel Assemblies are stored in an inert atmosphere and under conditions of temperature preventing from degradation of rod cladding; Sub-criticality controlled by adequate arrangements in any conditions; Safe facility meeting ICPR 60 Requirements as well as all applicable regulations (including severe weather conditions and earthquake); Safe ...
2001-06-18
Materials performance at the Wilsonville Coal Liquefaction Facility, 1989--1991
The Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama, is funded by the US Department of Energy (DOE), the Electric Power Research Institute (EPRI), and Amoco Corporation. On behalf of these organizations, Southern Company Services manages and Southern Clean Fuels Division of Southern Electric International operates the Wilsonville facility. Oak Ridge National Laboratory (ORNL) receives funding from DOE to provide materials technical support to the Wilsonville operators. For the period July 1987 through November 1990 the plant was operated with two reactors a thermal reactor and a catalytic reactor in a close-coupled integrated two-stage liquefaction mode. Coal processed was obtained from several seams including Ohio No. 6, Illinois No. 6, and Pittsburgh No. 8, as well as Texas lignite and several subbituminous coals. Corrosion samples which were removed for examination at the end of this period were exposed ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a summer and a winter period following the successful startup and Operational phase of the completed ...
1992-09-21
Innovative coke oven gas cleaning system for retrofit applications
Energy Technology Data Exchange (ETDEWEB)
The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a summer and a winter period following the successful startup and Operational phase of the completed ...
1992-09-21
Experiments with the HORUS-II test facility
Energy Technology Data Exchange (ETDEWEB)
Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as ...
1997-12-31
European facilities for accelerator neutrino physics: perspectives for the decade to come
Very soon a new generation of reactor and accelerator neutrino oscillation experiments - Double Chooz, Daya Bay, Reno and T2K - will seek for oscillation signals generated by the mixing parameter theta_13. The knowledge of this angle is a fundamental milestone to optimize further experiments aimed at detecting CP violation in the neutrino sector. Leptonic CP violation is a key phenomenon that has profound implications in particle physics and cosmology but it is clearly out of reach for the aforementioned experiments. Since late 90's, a world-wide activity is in progress to design facilities that can access CP violation in neutrino oscillation and perform high precision measurements of the lepton counterpart of the Cabibbo-Kobayashi-Maskawa matrix. In this paper the status of these studies will be summarized, focusing on the options that are best suited to exploit existing European facilities (firstly CERN and the INFN Gran ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
In this report, the descriptions of the DIVA test facility and those test matrixes are presented. The test sections simulate the downcomer annulus of DVI system with various scalling methodologies. The UPTF one has 1/7.5 scale and the APR-1400 test sections are reduced in 1/7 scale and 1/5 scale respectively. Also, the instrumentations, measuring methods are described. The major measuring parameters are ECC injection rate, air injection rate, bypass fraction, system pressure and so on. And finally, the operation procedure and experimental steps are introduced. From the DIVA tests, the multi-dimensional behaviors of two-phase flow in the downcomer during the reflood phase can be investigated using a transparent test facility. Also comparing the experimental data which are performed in various scale downcomer, it is expected that some criteria of scalling methodology proper to the DVI system can be derived. 10 refs., 19 ...
2002-03-01
Break Nodalization Influence to IAEA-SPE-4 Test Simulation
International Nuclear Information System (INIS)
A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and ...
1998-06-15
Energy Technology Data Exchange (ETDEWEB)
Previous analyses of binary cycles for conversion of geothermal energy from moderate temperature resources to electrical energy have shown potential gains in net geofluid effectiveness of on the order of 8%, resulting from selection of turbine-expansion processes whose equilibrium states pass through the two-phase region (assuming major condensation does not occur). If condensation occurs, this gain could be reduced or eliminated by the resulting loss in turbine efficiency. Experience with many fluids, however, indicates that vapor supersaturation (or subcooling) permits metastable pure-vapor states to exist at temperatures considerably below the saturation temperature at a given pressure; thus, by better understanding the condensation process, and properly structuring the cycle, substantial performance gains may be achievable. The present study assessed, qualitatively, the probability for attaining this performance gain.
1982-07-01
British Library Electronic Table of Contents (United Kingdom)
Background: Ecchymosis, oedema, haematoma and pain after SMAS-based facelift surgery are all the direct result of the physical trauma of surgery and subsequent inflammatory response. Hilotherapy is a novel form of cryotherapy that purports to minimise these events through single-use face masks circulating cooled, sterile water. This study was performed to assess the validity of Hilotherapy in this population of patients. Methods: Over 14 weeks fifty consecutive patients were randomised to post-operative facial cooling with Hilotherapy or management with standard dressings alone, while fifteen subsequent, consecutive patients were randomised to cooling of one side of the face but not the other. Assessment of ecchymosis, oedema, haematoma and pain was performed independently by clinical staf...
2011-01-01
Improving Dynamic Load and Generator Response PerformanceTools
Energy Technology Data Exchange (ETDEWEB)
This report is a scoping study to examine research opportunities to improve the accuracy of the system dynamic load and generator models, data and performance assessment tools used by CAISO operations engineers and planning engineers, as well as those used by their counterparts at the California utilities, to establish safe operating margins. Model-based simulations are commonly used to assess the impact of credible contingencies in order to determine system operating limits (path ratings, etc.) to ensure compliance with NERC and WECC reliability requirements. Improved models and a better understanding of the impact of uncertainties in these models will increase the reliability of grid operations by allowing operators to more accurately study system voltage problems and the dynamic stability response of the system to disturbances.
2005-11-01
Distinguishing three levels in explicit self-awareness
British Library Electronic Table of Contents (United Kingdom)
This paper focuses on the development of explicit self-awareness in children. Mirror self-recognition has been the most popular paradigm used to assess this ability in children. Nevertheless, according to Rochat (2003), there are, at least, three different levels of explicit self-awareness. We therefore designed three different self-recognition tasks, each corresponding to one of these levels (a mirror self-recognition task, a picture self-recognition task and a masked self-recognition task). We observed a decrease in performance across the three tasks. This supports a developmental scale in self-awareness. Besides, the masked self-recognition performance makes it possible to assess the final and the most sophisticated level of self-awareness, i.e. the external self. To our best knowledge,...
2011-01-01
Phase report 1C, TA-21 operable unit RCRA Facility Investigation, Outfalls Investigation
Energy Technology Data Exchange (ETDEWEB)
This phase report summarizes the results of field investigations conducted in 1992 at Technical Area 21 of Los Alamos National Laboratory, as prescribed by the RCRA Facility Investigation work plan for the Technical Area 21 operable unit (also known as OU 1106). This phase report is the last part of a three-part phase report describing the results of field work conducted in 1992 at this operable unit. Phase Report lA, issued on l4 June l993, summarized site geologic characterization activities. Phase report 1B, issued on 28 January 1994, included an assessment of site-wide surface soil background, airborne emissions deposition, and contamination in the locations of two former air filtration buildings. The investigations assessed in Phase Report 1C include field radiation surveys and surface and near-surface sampling to characterize potential contamination at 25 outfalls and septic systems listed as SWMUs in the RFI work ...
1994-02-28
Geothermal heat cycle research: Supercritical cycle with horizontal counterflow condenser
Energy Technology Data Exchange (ETDEWEB)
The Heat Cycle Research Program, which is being conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. To meet this objective, the program has as one of its goals to improve the performance of geothermal binary cycles to levels approaching the practicable thermodynamic maximum. In pursuit of this goal, tests are being conducted at the Heat Cycle Research Facility located at the DOE Geothermal Test Facility, East Mesa, California. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. In addition to the present test program, preparations are being made to investigate the binary cycle ...
1987-01-01
The Los Alamos National Laboratory Environmental Restoration Program
Energy Technology Data Exchange (ETDEWEB)
The LANL Environmental Restoration (ER) Program Office, established in October 1989, is faced with the challenge of assessing and cleaning up nearly 1,8000 potentially hazardous waste sites according to an aggressive corrective action schedule that the Environmental Protection Agency (EPA) mandated on May 23, 1990, in a Resource, Conservation, and Recovery Act (RCRA) Part B Permit. To maximize program efficiency, the ER Program Office will implement a unique management approach designed to maximize the use of laboratory technical expertise. The Installation Work Plan, which provides a blueprint for the program, has been submitted to EPA for review and approval. A work plan for characterization of Technical Area 21, an early plutonium processing facility, is also nearing completion. The feasibility of an expedited cleanup of the Laboratory's worst hazardous waste release has been modelled using a computer code originally developed by ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The criterion the study is based on in evaluating environmental risks is the possibility of harmful changes in air, water and soils rather than the harmful environmental impacts these changes are caused by. The two significant criteria, i.e. the evaluated environmental hazards potentials or 'value parameters', and the evaluated damage-to-the-environment probabilities or 'safety parameters', reveal the respective environmental risks or 'risk factors'. These risk factors are classified by 23 environmental risk parameters for differentiation between low-risk and high-aid for pollution abatement measures provided that one fixes acceptance limits for the environmental parameters. As a rule the environmental risks of technical facilities which handle hazardous materials can be evaluated appropriately and the results can be compared. (orig./HSCH).
1992-02-07
Energy recovery for Kent and Sussex Counties, Delaware: Phase II study report
Energy Technology Data Exchange (ETDEWEB)
The work reported is to evaluate two alternative resource recovery systems which would produce a fuel or an energy product (steam) for sale to an industrial plant. The first alternative is a refuse derived fuel (RDF) production facility which would process waste to produce fuel for sale to the plant. The RDF would be co-fired with coal in new boilers. The second alternative is a mass burn steam generation facility which would produce high pressure superheated steam for sale. The steam would be used by the plant to cogenerate electricity and for the process. Conceptual designs are developed for each alternative to form the basis of estimates of capital and operating costs and potential energy revenues. Operating requirements are developed for both alternatives. An assessment is made of the impact of both alternatives on the environment, and it is concluded that the impact of either alternative will be negligible. Order of ...
1982-12-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this Energy Engineering Analysis (EEA) for LSAAP is threefold: Develop a systematic plan of projects which will result in reducing energy consumption. Consider renewable energy sources with the objective of establishing an orderly procedure for reducing use of non-renewable energy sources. Determine the feasibility of Total Energy (TE), Selective Energy (SE), and Central Heating Plant (CHP) concepts using alternative fuels. In essence, an assessment of the entire energy picture at LSAAP was undertaken. This report is a summary of that effort. LSAAP was originally built during 1941 and 1942 as a shell loading plant for the Army. After World War II, the facility was deactivated until 1951 when it was reactivated as a Government Owned, Contractor Operated (GOCO) facility. Day and Zimmerman was selected as the operator in 1951 and has been the operating contractor ever since. Located just west of Texarkana, ...
1981-12-31
DWPF waste form compliance plan (Draft Revision)
Energy Technology Data Exchange (ETDEWEB)
The Department of Energy currently has over 100 million liters of high-level radioactive waste in storage at the Savannah River Site (SRS). In the late 1970's, the Department of Energy recognized that there were significant safety and cost advantages associated with immobilizing the high-level waste in a stable solid form. Several alternative waste forms were evaluated in terms of product quality and reliability of fabrication. This evaluation led to a decision to build the Defense Waste Processing Facility (DWPF) at SRS to convert the easily dispersed liquid waste to borosilicate glass. In accordance with the NEPA (National Environmental Policy Act) process, an Environmental Impact Statement was prepared for the facility, as well as an Environmental Assessment of the alternative waste forms, and issuance of a Record of Decision (in December, 1982) on the waste form. The Department of Energy, recognizing that ...
1991-01-01
DWPF waste form compliance plan (Draft Revision)
Energy Technology Data Exchange (ETDEWEB)
The Department of Energy currently has over 100 million liters of high-level radioactive waste in storage at the Savannah River Site (SRS). In the late 1970`s, the Department of Energy recognized that there were significant safety and cost advantages associated with immobilizing the high-level waste in a stable solid form. Several alternative waste forms were evaluated in terms of product quality and reliability of fabrication. This evaluation led to a decision to build the Defense Waste Processing Facility (DWPF) at SRS to convert the easily dispersed liquid waste to borosilicate glass. In accordance with the NEPA (National Environmental Policy Act) process, an Environmental Impact Statement was prepared for the facility, as well as an Environmental Assessment of the alternative waste forms, and issuance of a Record of Decision (in December, 1982) on the waste form. The Department of Energy, recognizing that start-up of ...
1991-12-31
Experience in complying with quality assurance requirements for cask lifting devices
International Nuclear Information System (INIS)
The Nuclear Assurance Corporation (NAC) owns and operates four NAC-1 truck casks. These casks are used to ship spent reactor fuel assemblies and radioactive reactor-core components. The casks have been loaded or unloaded at a total of fifteen nuclear facilities in the United States. In addition, NAC has used another large, overweight-truck cask to ship radioactive reactor core components from a reactor to a waste burial site. There are many individual differences in the cask handling facilities at each of the reactor stations, nuclear research facilities and the storage and burial sites serviced. Various types of auxiliary lifting and handling devices for on-site cask operations have been required. The quality assurance requirements for the equipment used in interfacing casks with nuclear power plant facilities have become more stringent. This paper presents details on the type of special equipment ...
Energy Technology Data Exchange (ETDEWEB)
A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA ...
1981-01-01
Effect of gasoline octane quality on vehicle acceleration performance
Energy Technology Data Exchange (ETDEWEB)
A study was conducted under the auspices of the Coordinating Research Council, Inc. (CRC) to assess the potential effects of gasoline octane quality on vehicle acceleration performance. Twelve participating laboratories, representing both the oil and the automotive industries, tested a total of 182 vehicles as part of the 1989 CRC Octane Number Requirement Survey. The vehicles consisted of 78 with electronic knock control systems and 104 without. All testing was performed using the 1989/1990 CRC FBRU fuel series. The results showed that acceleration performance of vehicles with knock sensors was significantly affected by gasoline octane quality. Octane effects on acceleration performance were most pronounced at maximum-throttle (detent) conditions and at octane levels below the vehicles' octane requirements; however, some knock-sensor vehicles did show improved acceleration ...
1991-07-01
Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory
Energy Technology Data Exchange (ETDEWEB)
The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the ...
2008-07-14
Woody biomass availability for bioethanol conversion in Mississippi
British Library Electronic Table of Contents (United Kingdom)
This study evaluated woody biomass from logging residues, small-diameter trees, mill residues, and urban waste as a feedstock for cellulosic ethanol conversion in Mississippi. The focus on Mississippi was to assess in-state regional variations and provide specific information of biomass estimates for those facilities interested in locating in Mississippi. Supply and cost of four woody biomass sources were derived from Forest Inventory Analysis (FIA) information, a recent forest inventory conducted by the Mississippi Institute for Forest Inventory, and primary production costs. According to our analysis, about 4.0 million dry tons of woody biomass are available for production of up to 1.2 billion liters of ethanol each year in Mississippi. The feedstock consists of 69% logging residues, 21%...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Within the framework of efforts to optimize state-of-the-art waste disposal methods, this research project makes a theoretical analysis of the propagation behaviour of pollutants from landfills and waste incineration plants into the immediate vicinity of such plants. In order to judge the propagation of pollutants near the above-mentioned waste disposal facilities, a calculation program was developed within the framework of this research project which permits simulation of the propagation of such emissions in a three-dimensional space by application of an Eulerian grid model. It is capable of realistically representing fluid flow conditions and pollutant concentrations for certain points of times within the complex building patterns of such plants, for randomly chosen atmospheric conditions. (orig.)
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Previous reports have stressed the importance of the nutrient blood supply in rib grafts transferred by microvascular anastomoses. In the present experimental study, we have demonstrated that a rib graft transferred by microvascular anastomoses based on periosteal vessels can survive; vascular clearing studies demonstrated that the vascularity of these grafts extends not only into the cortex but the medulla as well. The relative facility of harvesting these grafts (compared with those based on nutrient vessels) should make them the favored choice. Technetium bone scintigraphy proved accurate in the assessment of both vascular pattern and microanastomotic patency. Tetracycline labeling did not correlate well with the patency of a rib graft's pedicle blood supply.
1984-11-01
Risk analysis in oil spill response planning
Energy Technology Data Exchange (ETDEWEB)
Tiered response is a basic approach to emergency plans, including oil spill response (OSR). This paper delineates a huge set of accidental scenarios within a certain tier of response generated by a computer during risk assessment. Parameters such as the amount of oil spilled, duration of discharge and types of losses should be provided in OSR scenarios. Examples of applications include offshore installations, sub sea or onshore pipelines, and localized onshore facilities. The paper demonstrates how to use risk analysis results for delineating all likely spills into groups that need a specific tier response. The best world practices and Russian regulatory approaches were outlined and compared. Corresponding algorithms were developed and their application in pipelines was presented. The algorithm combines expert's skills and spill trajectory modeling with the net environmental benefit analysis principle into the incident specific ...
2005-07-01
Reliability data update method for emergency diesel generator of Daya Bay Nuclear Power Plant
British Library Electronic Table of Contents (United Kingdom)
In the field of Living Probabilistic Safety Assessment (LPSA) the reliability data updating is an important factor. In risk analysis equipment failure data is needed to estimate the frequencies of events contributing to risk posed by a facility. Five years data of emergency diesel generator (EDG) of Daya Bay Nuclear Power Plant (NPP) has been studied in this paper. The data updating process has been done by using two methods, i.e., the classical method and Bayesian method. The aim of using these methods is to calculate the operational failure rate (@l) and demand failure probability (p). The results show that the operational failure rate is 1.7E-3 per hour and the demand failure probability is 2.4E-2 demand per day for Daya Bay NPP. By comparing the results obtain from classical and Bayesi...
2011-01-01
Pre-test report on international round robin analysis of BARC containment (BARCOM) test model
International Nuclear Information System (INIS)
BARC has organized an international round robin analysis program to carry out the ultimate load capacity assessment of BARC containment (BARCOM) test model. The test model located in BARC facilities Tarapur, is a 1:4 scale representation of 540 MWe pressurized heavy water reactor (PHWR) pre-stressed concrete inner containment structure of Tarapur Atomic Power Station (TAPS) unit 3 and 4. The features of the BARCOM test model and the constitutive data for the pre-test analysis along with the comparison of the results submitted by various participants are described in this pre-test report of the round robin analysis of BARCOM test model
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The application of a method for determining the temperature of an oxygen-replenished air stream heated to 2600 K by a hydrogen burner is reviewed and discussed. The purpose of the measurements is to determine the spatial uniformity of the temperature in the core flow of a ramjet test facility. The technique involves sampling the product gases at the exit of the test section nozzle to infer the makeup of the reactant gases entering the burner. Knowing also the temperature of the inlet gases and assuming the flow is at chemical equilibrium, the adiabatic flame temperature is determined using an industry accepted chemical equilibrium computer code. Local temperature depressions are estimated from heat loss calculations. A description of the method, hardware and procedures is presented, along with local heat loss estimates and uncertainty assessments. The uncertainty of the method is estimated at {+-}31 K, and the spatial uniformity was measured ...
1995-08-01
Improvements in the cost of liquid fuels from direct coal liquefaction
International Nuclear Information System (INIS)
This paper presents an assessment of recent improvements in the technology for direct coal liquefaction on the estimated commercial economics. The basis for the design and cost estimates is a series of studies sponsored by Amoco Corporation and Electric Power Research Institute, which were derived from the highly detailed Breckinridge Project, completed in the early 1980s under DOE sponsorship. The technology, design, and cost estimates reflect the current two-stage liquefaction technology practiced at the Advanced Coal Liquefaction Research facility in Wilsonville, Alabama. Details of the design bases and cost estimates and how they compare with the original Breckinridge study are described. Also examined are effects of feed coal rank, product slate, and the source of hydrogen (natural gas or coal) on the costs. Finally, the ways that projected future improvements in the technology will change the design and lead to lower costs are discussed. ...
Environmental implications of coal gasification/liquefaction technologies in Canada
Energy Technology Data Exchange (ETDEWEB)
This report reviews coal conversion processes which may be introduced in Canada within the next decade if interest in alternate energy technologies continues. A detailed review was conducted on coal liquefaction and gasification projects worldwide including information on individual proprietors, process technologies used, their present status and available environmental data. Further assessment of emissions and wastes emanating from commercial-scale plants was used to determine significant or potentially significant wastestreams connected to the various technologies, particularly wastewater discharges. Emphasis was placed on those technologies that are close to commercialization in Canada, i.e. SASOL II-type liquefaction facility at Hat Creek. Available information on wastewater treatment/reuse is also included in this report.
1983-01-01
Environmental hazards for pipelines in coastal regions/shore approaches
Energy Technology Data Exchange (ETDEWEB)
Often oil/gas and other hydrocarbons discovered and produced offshore are transported to onshore facilities via submarine pipelines. The route of such pipelines traverses through coastal/shore approach regions. For a rational/economic design, safe installation and subsequent operation it is of utmost importance to review, evaluate and finalize various environmental hazard such as winds, waves, currents, seabed topography, seabed and sub-bottom soils, seabed erosion and soil accretion. This paper addresses the above described environmental hazards, their assessment and techniques to prepare design parameters which must be used for stability analysis, installation methods, long term operation and maintenance for the shore approaches. Additionally, various proven pipeline installation and stabilization techniques for the shore approach region are detailed. As case histories, three approaches installed in the Dutch North Sea are described.
1995-12-31
International Nuclear Information System (INIS)
Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)
1998-10-30
Energy Technology Data Exchange (ETDEWEB)
This comprehensive final report for the Swiss Federal Office of Energy (SFOE) examines ways to optimise energy flows in mains networks that include distributed generation facilities. Increasing use of decentralised generation, its effects on the operation of low-voltage mains and the efficient use of the 400 V mains is discussed. The principles of operation and construction of controlled storage installations are discussed and concrete examples of their use in both grid-connected and island operation are quoted. Alternatives to storage are looked at from both the technical and economic points of view. The storage technologies used such as flywheels, supercaps, redox-flow batteries and lead-acid accumulators are briefly assessed and the results of simulations are discussed.
2005-07-01
International Nuclear Information System (INIS)
During the phases of separation, treatment, conditioning and storage of radioactive waste, destructive and nondestructive methods for their characterization are needed. In order to satisfy this necessity, in the frame of the National Program of Research and Development, the 'Laboratory for characterization of spent nuclear fuel and high/medium level radioactive waste- LABORAD' was created. The purpose of the project was to accredit the analysis methods available in the laboratory, and also to develop new methods for the characterization of the radioactive waste. A special attention was paid to the high-level radioactive waste and spent nuclear fuel characterization that require special facilities for handling. These facilities (e.g. hot cells, remote handlers, transport container) are already available in our institute. Experimental results and performances obtained during validation of the methods are presented in this ...
2009-05-27
COVFILS-2: neutron data and covariances for sensitivity and uncertainty analysis
Energy Technology Data Exchange (ETDEWEB)
The author have prepared a new, fusion-oriented library of multigroup neutron cross sections, scattering matrices, and covariances (uncertainties and correlations). The 74-group library, called COVFILS-2, has been used, or will be used, by neutronics groups at Los Alamos National Lab. (LANL) at the University of California at Los Angeles, and at the Swiss Federal Institute for Reactor Research in the sensitivity and uncertainty analysis of fusion-relevant integral experiments such as the Li/sub 2/O experiment performed at the Fast Neutron Source Facility in Japan and the Lithium breeding module experiment planned at the LOTUS facility in Lausanne, Switzerland. Another intended use of this library is in the estimation of the uncertainty in key performance parameters (such as the breeding ratio) of conceptual fusion reactors. The 14 materials included in the first version of COVFILS-2 are hydrogen, /sup ...
1986-01-01
COVFILS-2: neutron data and covariances for sensitivity and uncertainty analysis
International Nuclear Information System (INIS)
The author have prepared a new, fusion-oriented library of multigroup neutron cross sections, scattering matrices, and covariances (uncertainties and correlations). The 74-group library, called COVFILS-2, has been used, or will be used, by neutronics groups at Los Alamos National Lab. (LANL) at the University of California at Los Angeles, and at the Swiss Federal Institute for Reactor Research in the sensitivity and uncertainty analysis of fusion-relevant integral experiments such as the Li_2O experiment performed at the Fast Neutron Source Facility in Japan and the Lithium breeding module experiment planned at the LOTUS facility in Lausanne, Switzerland. Another intended use of this library is in the estimation of the uncertainty in key performance parameters (such as the breeding ratio) of conceptual fusion reactors. The 14 materials included in the first version of COVFILS-2 are hydrogen, "6Li, "7Li, ...
1986-06-15
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of Run 260 performed at the Advanced Coal Liquefaction R&D Facility in Wilsonville. The run was started on July 17, 1990 and continued until November 14, 1990, operating in the Close-Coupled Integrated Two-Stage Liquefaction mode processing Black Thunder mine subbituminous coal (Wyodak-Anderson seam from Wyoming Powder River Basin). Both thermal/catalytic and catalytic/thermal tests were performed to determine the methods for reducing solids buildup in a subbituminous coal operation, and to improve product yields. A new, smaller interstage separator was tested to reduce solids buildup by increasing the slurry space velocity in the separator. In order to obtain improved coal and resid conversions (compared to Run 258) full-volume thermal reactor and 3/4-volume catalytic reactor were used. Shell 324 catalyst, 1/16 in. cylindrical extrudate, at a replacement rate of 3 lb/ton of MF coal was ...
1992-01-01
Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama
Energy Technology Data Exchange (ETDEWEB)
This report presents the results of Run 260 performed at the Advanced Coal Liquefaction R D Facility in Wilsonville. The run was started on July 17, 1990 and continued until November 14, 1990, operating in the Close-Coupled Integrated Two-Stage Liquefaction mode processing Black Thunder mine subbituminous coal (Wyodak-Anderson seam from Wyoming Powder River Basin). Both thermal/catalytic and catalytic/thermal tests were performed to determine the methods for reducing solids buildup in a subbituminous coal operation, and to improve product yields. A new, smaller interstage separator was tested to reduce solids buildup by increasing the slurry space velocity in the separator. In order to obtain improved coal and resid conversions (compared to Run 258) full-volume thermal reactor and 3/4-volume catalytic reactor were used. Shell 324 catalyst, 1/16 in. cylindrical extrudate, at a replacement rate of 3 lb/ton of MF coal was used ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
Some diagnostics at the National Ignition Facility (NIF), including the Gamma Reaction History (GRH) diagnostic, require multiple channels of data to achieve the required dynamic range. These channels need to be stitched together into a single time series, and they may have non-uniform and redundant time samples. We chose to apply the popular cubic smoothing spline technique to our stitching problem because we needed a general non-parametric method. We adapted one of the algorithms in the literature, by Hutchinson and deHoog, to our needs. The modified algorithm and the resulting code perform a cubic smoothing spline fit to multiple data channels with redundant time samples and missing data points. The data channels can have different, time-varying, zero-mean white noise characteristics. The method we employ automatically determines an optimal smoothing level by minimizing the Generalized Cross Validation (GCV) score. In order to automatically ...
2010-12-28
Radiological hazards in uranium mines and a yellow-cake plant in Turkey
Energy Technology Data Exchange (ETDEWEB)
Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.
1984-06-01
Quality Concepts for the Improved Use of Recycled Polymeric Materials: A Review
British Library Electronic Table of Contents (United Kingdom)
Polymeric waste materials should be considered resources for the manufacture of new products through recycling processes, with a similar status to virgin fossil-based plastics and biopolymers from renewable resources. Several efforts can be made to achieve this qualitative quantum leap in plastics recycling, and consequently introduce recycled products, with competitive performance, to the market. Scientific knowledge about the degradation processes during the life cycle and the development of fast and reliable analytical methods for the quality assessment of recycled plastics are fundamental to guarantee their performance in new applications. Different strategies-restabilisation, rebuilding, compatibilisation, and addition of elastomers and fillers-can be used to upgrade the structure and...
2008-01-01
International Nuclear Information System (INIS)
The analysis for priority rankings of the recommendations to reduce the total core damage frequency (CDF) of Wolsong nuclear power plant units 2/3/4 was performed in this paper. In order to derive the recommendations, the sensitivity analysis of CDF on which major contributors effect was performed based on the accident quantification results during Level 1 probabilistic safety assessments (PSA). Priorities were ranked in the way that compares the CDF reduction rate with the efforts required to implement those recommendations using risk matrix.
1998-05-01
Improvement of assessment methodology for fluid flow characteristics of passive flow control device
International Nuclear Information System (INIS)
The objective of this study is to establish evaluation and verification guideline for the APR 1400 and to investigate the thermal-hydraulic characteristics for fluidic device is analyzed using FLUENT. The scope and major results of research are flow characteristics for fluidic device. In this study, three-dimensional numerical model for fluidic device is developed adequately for, and results are compared with experimental data performed by VAPER (VAlve Performance Evaluation test Rig) in KAERI with an aim to verify numerical simulation. In addition, the parametric study has also carried out to investigate the effect of major parameters such as velocity and pressure inside FD chamber.
2002-10-01
Ethnic Diversity and Economic Performance
...Ethnic Diversity and Economic Performance Alberto Alesina & Eliana La Ferrara Alberto Alesina; Eliana La Ferrara This file is part of IDEAS, which ...Publisher info | Download info | Related research | StatisticsAuthor Info Alberto Alesina Eliana La Ferrara Additional information is available for the following registered author(s):...Alberto Alesina Eliana La Ferrara Abstract We survey and assess the literature on the positive and negative effects of ethnic diversity on economic policies ...research Keywords: Other versions of this item: Paper Alberto Alesina & Eliana La Ferrara, 2003. \\
Energy Technology Data Exchange (ETDEWEB)
An overall view of the 1982 plant operating performance is presented. All periods of ON-FEED operation, UNSCHEDULED SHUTDOWNS, and SCHEDULED SHUTDOWNS are accounted for and tabulated. Causes of UNSCHEDULED SHUTDOWNS are identified and discussed. Plant solutions aimed at reducing the effect of similar future shutdowns or preventing recurrence of such shutdowns are explained. Details of repeated, major maintenance problems with various pieces of equipment are presented. Discussion of each problem and solutions found during 1982 are given, where applicable.
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
This study investigates spent fuel cask handling experience at existing nuclear facilities to determine appropriate cask decontamination and maintenance operations at the potential Yucca Mountain repository. These operations are categorized as either routine or nonroutine. Routine cask decontamination and maintenance tasks are performed in the cask preparation area at the repository. Casks are taken offline to a separate cask maintenance area for major nonroutine tasks. The study develops conceptual designs of the cask preparation area and cask maintenance area. The functions, layouts, and major features of these areas are also described.
1992-04-01
International Nuclear Information System (INIS)
Thermal analysis testing revealed slight weight changes, which were a function of gamma irradiation, in a highly reduced Defense Waste Processing Facility (DWPF) simulated waste glass. Transmission electron microscopy (TEM) was performed on this glass to determine if the weight change corresponded to microstructural variations. TEM analyses showed that no microstructural changes were attributable to gamma irradiation. Exposure of the samples to the electron beam in the TEM did cause changes in the glass microstructures in some cases. These changes were likely due to localized heating of the glass due to interactions with the transmitted electrons.
1994-04-25
The use of combustible metals in explosive incendiary devices
Energy Technology Data Exchange (ETDEWEB)
We have investigated tailoring damage effects of explosive devices by addition of unconventional materials, specifically combustible metals. Initial small-scale as well as full-scale testing has been performed. The explosives functioned to disperse and ignite these materials. Incendiary, enhanced-blast, and fragment-damage effect have been identified. These types of effects can be used to extend the damage done to hardened facilities. In other cases it is desirable to disable the target with minimal collateral damage. Use of unconventional materials allows the capability to tailor the damage and effects of explosive devices for these and other applications. Current work includes testing of an incendiary warhead for a penetrator.
1996-08-01
State of Surgery in Tropical Africa: A Review
British Library Electronic Table of Contents (United Kingdom)
This is a review of recently published literature on surgery in tropical Africa. It presents the current state of surgical need and surgical practice on the continent. We discuss the enormous burden of surgical pathology (as far as it is known) and the access to and acceptability of surgery. We also describe the available facilities in terms of equipment and manpower. The study looked at the effects of the human immunodeficiency virus, the role of traditional healers, anesthesia, and the economics of surgery. Medical training and research are discussed, as are medical migration out of Africa and the concept of task shifting, where surgical procedures are performed by others when surgeons are not available. It closes with recommendations for involvement and action in this area of great glob...
2011-01-01
Simultaneous measurement of the neutron capture and fission yields of "2"3"3U
International Nuclear Information System (INIS)
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
2007-04-22
Energy Technology Data Exchange (ETDEWEB)
The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).
1985-02-01
Energy Technology Data Exchange (ETDEWEB)
The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.
1985-02-01
In situ observation of axial irradiation growth in liquid-metal reactor metal fuel
International Nuclear Information System (INIS)
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
1989-11-26
Distributed-processing radiation management system for nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)
1999-06-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
Energy Technology Data Exchange (ETDEWEB)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.
2003-10-01
Safety assessment for clearance of radioactive metal wastes from nuclear facility
International Nuclear Information System (INIS)
Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.
2003-10-01
Research study for extremely unlikely scenario of high level waste disposal: Part 3
Energy Technology Data Exchange (ETDEWEB)
In this research, first, event and process relevant to the key words (or scenario initiator) such as volcanism have been identified and, especially a middle-scale eruption scenario including pyroclastic flows has been analyzed as the catastrophic scenario, which inspires ordinary people to have tremendous concern. Secondly, based upon the characteristic events and processes of each scenario considered in the above and through the research of existing model of such risk, quantitative concept (release amount magnitude, release mode, release form, frequency of release, probability etc.) and impact on repository system, facility and environment have been analyzed, defended and defined. Model which can assess and analyze such impact has been built. Using these models, risks directly or indirectly caused by HLW repository have been calculated. Finally, the process for assessing the consequence of volcanism scenario and its risk ...
1999-02-01
Development of `health and environmental safety assessment network system (HESANS)`
Energy Technology Data Exchange (ETDEWEB)
With the recent advance of the utilization of nuclear energy in a large scale, social interest is being focussed in the potential risk which the nuclear technology will accompany. Especially after the accidents in Chernobyl and other nuclear facilities, serious anxiety to the utilization of nuclear energy is prevailing among the general public. In order to meet the anxiety and distrust of the population in the use of the nuclear power, the health effect or risk which radioactive materials released into the environment will bring about should be comprehensively and properly evaluated, and then should be widely reported to the population. The development of HESANS code system (Health and Environmental Safety Assessment Network System) was planned to set up such a comprehensive computer code that covers a whole pathway of radioactive material from its release to estimates of derived health effects in the population, including the countermeasures ...
1994-03-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
Energy Technology Data Exchange (ETDEWEB)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The ...
2007-07-01
CFD Application to the Regulatory Assessment of FAC-Caused CANDU Feeder Pipe Wall Thinning Issue
International Nuclear Information System (INIS)
From the results of the In-Service Inspection (ISI) measuring the wall thickness of outlet (hot-leg side) feeder pipes performed at two Canadian nuclear power plants, Point Lepreau and Gentilly-2 in 1995 and 1996, respectively, the wall thinning degradation of feeder pipes at the bend part was found to be much more severe than expected. It has been well known that such wall thinning of feeder pipes is caused by the flow accelerated corrosion (FAC) which is one of the mechanical-chemical degradation mechanisms affecting the integrity of piping systems. For the Wolsung unit 1, the wall thickness measurements have been performed during every overhaul period since 1996. The wall thinning rates at the bends of outlet feeder pipes were assessed to exceed the design value. However, for the Wolsung units 2, 3 and 4, the wall thinning rates of all the outlet feeder pipes were assessed not to exceed it. The ...
2007-05-10
Assessment of RELAP5/MOD3/CANDU"+ to Wolsung-1 D_2O leakage event
International Nuclear Information System (INIS)
In order to evaluate the integrated performance of RELAP5/MOD3/CANDU"+ for CANDU operational transient analysis, we assesed the code to the D_2O leakage event occurred at Wolsung-I, 600 MW(e) CANDU reactor, on Oct. 20, '94. D_2O leakage event was initiated by stuck opening of liquid relief valve No.4 in primary coolant pressure and level control system. Assessment calculation was performed for the plant transients up to 1000 seconds after the initiating event. Calculation results are compared with those measured in primary heat transport system, pressure and inventory control system and boiler secondary system. Comparison with the plant trip log shows that the RELAP5/CANDU"+ is able to simulate the plant transients properly, from which we can conclude that the RELAP5/CANDU"+ is validated for application to CANDU operational transient analysis. CANDU specific models used in the assessment are fuel bundle ...
2001-10-01
Predictive Capability Maturity Model for computational modeling and simulation.
The Predictive Capability Maturity Model (PCMM) is a new model that can be used to assess the level of maturity of computational modeling and simulation (M&S) efforts. The development of the model is based on both the authors experience and their analysis of similar investigations in the past. The perspective taken in this report is one of judging the usefulness of a predictive capability that relies on the numerical solution to partial differential equations to better inform and improve decision making. The review of past investigations, such as the Software Engineering Institute's Capability Maturity Model Integration and the National Aeronautics and Space Administration and Department of Defense Technology Readiness Levels, indicates that a more restricted, more interpretable method is needed to assess the maturity of an M&S effort. The PCMM addresses six contributing elements to M&S: (1) representation and geometric ...
2007-10-01
In-vessel coolability and retention of a core melt. Volume 2
Energy Technology Data Exchange (ETDEWEB)
The efficacy of external flooding of a reactor vessel as a severe accident management strategy is assessed for an AP600-like reactor design. The overall approach is based on the Risk Oriented Accident Analysis Methodology (ROAAM), and the assessment includes consideration of bounding scenarios and sensitivity studies, as well as arbitrary parametric evaluations that allow the delineation of the failure boundaries. Quantification of the input parameters is carried out for an AP600-like design, and the results of the assessment demonstrate that lower head failure is physically unreasonable. Use of this conclusion for any specific application is subject to verifying the required reliability of the depressurization and cavity-flooding systems, and to showing the appropriateness (in relation to the database presented here, or by further testing as necessary) of the thermal insulation design and of the external surface properties ...
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
The DOE Working Group for an Assessment of Coal-Gasification Research Needs (COGARN - coal gasification advanced research needs) has reviewed and evaluated US programs dealing with coal gasification for a variety of applications. Cost evaluations and environmental-impact assessments formed important components of the deliberations. We have examined in some depth each of the following technologies: coal gasification for electricity generation in combined-cycle systems, coal gasification for the production of synthetic natural gas, coal gasifiers for direct electricity generation in fuel cells, and coal gasification for the production of synthesis gas as a first step in the manufacture of a wide variety of chemicals and fuels. Both catalytic and non-catalytic conversion processes were considered. In addition, we have constructed an orderly, long-range research agenda on coal science, pyrolysis, and partial combustion in order to support applied ...
1987-06-01
Summary of Omega West Reactor, Level 1, probabilistic risk assessment
International Nuclear Information System (INIS)
This paper reports on a Level 1 PRA performed on the Omega West Reactor at Los Alamos National Laboratory. A Master Logic Diagram was used to identify possible initiating events. A chi-square distribution was used to quantify initiating event frequencies given that no initiating events have occurred in 30 years of OWR operation. The PRA results are presented as both probability density function and cumulative distribution function curves.
1990-10-04
Scintigraphic assessment of pericardio-peritoneal window patency. Relevance to peritoneal dialysis.
To alleviate recurrent pericardial effusion secondary to systemic lupus erythematosus, pericardio-peritoneal window was performed. Subsequently, end stage renal disease developed and the patient required peritoneal dialysis. Patency of the pericardio-peritoneal window was demonstrated by intraperitoneal injection of Tc-99m SC through a Tenckhoff catheter, which prompted special counsel to the patient in order to prevent infectious pericarditis potentially complicating peritoneal dialysis induced-peritonitis. PMID:7554664
1995-07-01
Energy Technology Data Exchange (ETDEWEB)
As part of studies into the siting of a deep repository for nuclear waste, Swedish Nuclear Fuel and Waste Management Company (SKB) has commissioned the Alternative Models Project (AMP). The AMP is a comparison of three alternative modeling approaches for geosphere performance assessment for a single hypothetical site. The hypothetical site, arbitrarily named Aberg is based on parameters from the Aespoe Hard Rock Laboratory in southern Sweden. The Aberg model domain, boundary conditions and canister locations are defined as a common reference case to facilitate comparisons between approaches. This report presents the results of a discrete fracture pathways analysis of the Aberg site, within the context of the SR 97 performance assessment exercise. The Aberg discrete fracture network (DFN) site model is based on consensus Aberg parameters related to the Aespoe HRL site. Discrete fracture pathways are ...
1999-08-01
Mathematical analysis of the length-of-arc assumption
Energy Technology Data Exchange (ETDEWEB)
The observation by Maday in 1974 that the Schmidt-Duffin solution to the optimal fin profile problem was flawed due to neglect of the slant height factor led to a new solution--actually, a demonstration of the ill-posedness of the question--by Snider. The present article proves mathematically that omission of this factor leads inevitably to underestimation of the heat transfer capability of any fin. Additionally, a perturbation scheme for estimating the correction for this effect is derived for configurations with low generalized Biot numbers, and a revised assessment of the performance of the Schmidt fin is presented.
1996-04-01
Energy Technology Data Exchange (ETDEWEB)
The SRI International industrial team completed a subsystem and system parametric analysis, a 100-MW/sub e/ commercial plant conceptual design, a cost and performance analysis, and a commercial assessment. An executive summary is presented in this volume. (WHK)
1980-04-01
UK PubMed Central (United Kingdom)
ObjectiveWe wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional...Full Text Available
2006-01-01
International Nuclear Information System (INIS)
The Fusion Technology task performs analyses and systems studies of conceptual fusion reactors based upon inertial and high-#beta# magnetic confinement schemes. Progress in the areas of theoretical analysis (plasma and neutral-gas blanket models), specific reactor studies (toroidal and linear theta pinches, Z pinches, laser fusion) neutronic and nuclear data assessments, materials (metals and insulators) evaluation, and general engineering design is reported.
1976-12-01
Evaluation of 230 kV HPFF pipe-type cable with wrinkled and creased insulating tapes
Energy Technology Data Exchange (ETDEWEB)
Severe collapse wrinkles and circumferential creases were discovered in the cellulose paper insulating tapes of a newly installed IIPFF pipe-type cable during splicing and terminating. An evaluation program was developed to assess the electrical and mechanical integrity of the cable having wrinkled and creased insulating tapes. The test results indicated that the cable would perform satisfactorily in service.
1995-01-01
EMS and evaluation of environmental aspects: a review
International Nuclear Information System (INIS)
The Environmental Management System (EMS) is an instrument to manage the interaction between the organization and the environment. The scope od EMS is to reduce the environmental impact and to achieve improvements in overall performances. In particular, the focus point of EMS implementation is the method for identifying and assessing significant environmental aspects. This paper presents a review of methods and techniques existing in this area, and the definition of the state of the art. The results of the literature, regulation and case studies reviews have shown that rigorous, repeatable and transparent methodologies do not exist.
2006-04-01
Energy Technology Data Exchange (ETDEWEB)
The {sup 252}Cf-source-driven noise analysis method has been used in measurements for subcritical configurations of fissile systems for a variety of applications. Measurements of 25 fissile systems have been performed with a wide variety of materials and configurations. This method has been applied to measurements for (1) initial fuel loading of reactors, (2) quality assurance of reactor fuel elements, (3) fuel preparation facilities, (4) fuel processing facilities, (5) fuel storage facilities, (6) zero-power testing of reactors, and (7) verification of calculational methods for assemblies with the neutron k < l. These previous measurements, performed with a wide variety of multiplying systems, demonstrated the usefulness of the method. The high sensitivity of noise-measured parameters to small changes in fissile systems has been observed in several measurements. This high ...
1993-10-01
Food and biomass production in small oil expression facilities
Energy Technology Data Exchange (ETDEWEB)
This paper reported on a study in which rapeseeds were separated into high quality seed for food oil and low quality seed for biofuels. A laboratory-scale oilseed screw press was then used to examine the effects of choke opening and seed preheating on the rapeseed pressing performance and the quality of food oil and biofuels oil. Oil recovery and chlorophyll content was found to increase as maximum pressure increased. In terms of pressing performance, the rapeseed heated by microwaves yielded more oil and chlorophyll than without heating. The NEB ratio of microwave heating press with an 8.0 mm choke opening was advantageous. Rapeseed oil extracted from low quality seeds was found to have a high acid value. The quality of oil extracted by oilseed screw press was found to be good and met the requirements of the Codex Alimentarius for edible oils.
2010-07-01
Energy savings opportunity survey. US Army Field Station Kunia, Oahu, Hawaii. Final report
This Energy Savings Opportunity Survey (ESOS) is to identify Energy Conservation Opportunities (ECO`s) which are practical and economical for the reduction of energy consumption in accordance with the Army Facilities Energy Plan. The work to be performed under this project includes: (A) Coordinating with the on-going and proposed related projects. (B) Conducting a limited site survey required to identify applicable ECO`s and obtaining necessary data to evaluate the ECO`s. (C) Evaluating applicable ECO`s to determine their feasibility in accordance with current criteria. (D) Preparing programming and implementation documents for the recommended ECO`s. and (E) Preparing a comprehensive report to present the work performed including energy analysis, the results, and recommendations.
1989-06-01
Core demonstration lead experiments for irradiation in FFTF
International Nuclear Information System (INIS)
A major new initiative to develop and irradiate a long-life mixed oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by the Westinghouse Hanford Company at the Hanford Engineering Development Lab. for the US Dept. of Energy. The purpose of this new fuel system, called the Core Demonstration Experiment (CDE), is to demonstrate the capability of achieving a 3-yr life in a prototypical heterogeneous reactor environment under prototypical power and temperature conditions. Three Core Demonstration Lead Experiments (CDLEs) will establish the performance characteristics of entire fuel assemblies of wire-wrapped, large diameter, advanced oxide fuel pins with HT-9 stainless steel alloy cladding and wire wrap and an HT-9 duct. Their performance characteristics provided the basis for design, fabrication, and irradiation of the CDE.
1987-06-07
An intelligent design methodology for nuclear power systems
Energy Technology Data Exchange (ETDEWEB)
The goal of this investigation is to research possible methodologies into automating the design of, specifically, nuclear power facilities; however, it is relevant to all thermal power systems. The strategy of this research has been to concentrate on individual areas of the thermal design process, investigate procedures performed, develop methodology to emulate that behavior, and prototype it in the form of a computer program. The design process has been generalized as follows: problem definition, design definition, component selection procedure, optimization and engineering analysis, testing and final design with the problem definition defining constraints that will be applied to the selection procedure as well as design definition. The result of this research is a prototype computer program applying an original procedure for the selection of the best set of real components that would be used in constructing a system with desired ...
1989-01-01
LOBI/B-R1M, Loop for Blowdown Investigation, PWR Single-Ended Cold-Leg Break Experiment B EXP.B
International Nuclear Information System (INIS)
1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be simulated. The LOBI test facility is the only high pressure integral test facility ...
Synthesis and electrochemical performance of carbon nanofiber-cobalt oxide composites
Energy Technology Data Exchange (ETDEWEB)
Carbon nanofiber (CNF) supported cobalt oxide composites as high-capacity anode materials were prepared through a facile, effective method for potential use in rechargeable lithium-ion batteries. The effects of the calcining temperature on the crystallinity, grain size, specific surface area of Co{sub 3}O{sub 4} and phase transformation from Co{sub 3}O{sub 4} to CoO were studied in detail. Both the specific surface area and CNF content in CNF-cobalt oxide composites strongly affect the electrochemical performance of these series composites. The CNF-Co{sub 3}O{sub 4} composite with 24.3% CNF pyrolyzed at 500 deg. C in Ar shows an excellent cycling performance, retaining a specific capacity of 881 mAh g{sup -1} beyond 100 cycles. Homogeneous deposition and distribution of nanosized Co{sub 3}O{sub 4} particles on the surface of CNF can stabilize the electronic and ionic conductivity as well as the morphology of Co{sub 3}O{sub ...
2008-10-15
Synthesis and electrochemical performance of carbon nanofiber-cobalt oxide composites
Energy Technology Data Exchange (ETDEWEB)
Carbon nanofiber (CNF) supported cobalt oxide composites as high-capacity anode materials were prepared through a facile, effective method for potential use in rechargeable lithium-ion batteries. The effects of the calcining temperature on the crystallinity, grain size, specific surface area of Co{sub 3}O{sub 4} and phase transformation from Co{sub 3}O{sub 4} to CoO were studied in detail. Both the specific surface area and CNF content in CNF-cobalt oxide composites strongly affect the electrochemical performance of these series composites. The CNF-Co{sub 3}O{sub 4} composite with 24.3% CNF pyrolyzed at 500{sup o}C in Ar shows an excellent cycling performance, retaining a specific capacity of 881 mAh g{sup -1} beyond 100 cycles. Homogeneous deposition and distribution of nanosized Co{sub 3}O{sub 4} particles on the surface of CNF can stabilize the electronic and ionic conductivity as well as the morphology of Co{sub 3}O{sub ...
2008-10-15
Posttest analysis of the FFTF inherent safety tests
Energy Technology Data Exchange (ETDEWEB)
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest ...
1987-01-01
Posttest analysis of the FFTF inherent safety tests
International Nuclear Information System (INIS)
Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest ...
1987-06-07
Reduction in incidence of deep sternal wound infections: Random or real?
British Library Electronic Table of Contents (United Kingdom)
Objective Comorbidities predisposing cardiac surgical patients toward deep sternal wound infection, such as diabetes and obesity, are rising in the United States. Longitudinal analysis of risk factors, morbidity, and mortality was performed to assessed effects of these health trends on deep sternal wound infection rates. Methods In this retrospective analysis of all median sternotomies performed at a single institution from 1991 through 2006, demographic and surgical characteristics were identified from a prospective database. The cohort was separated into periods from 1992 through 2001 and 2002 through 2006 to identify longitudinal trends in risk factors for deep sternal wound infection. Univariate and matched multivariable analyses were performed. Results Overall, study population had in...
2010-01-01
International Nuclear Information System (INIS)
This report is the result of field work performed at the former White Point Nike Missile Site, San Pedro, California. The Hazardous Waste Remedial Actions Program tasked the Oak Ridge National Laboratory Pollutant Assessments Group in Grand Junction, Colo., with this project. The objective was to determine whether or not radioisotopes possibly associated with past Department of Defense (DOD) operations were present and within accepted background levels. The radiation survey was accomplished by performing three independent radiation surveys, both outdoors and indoors, and random soil sampling. Initially, the site was land surveyed to develop a grid block system. A background radiation investigation was performed out in the San Pedro area.
Influence of Pressurisation on SOFC Performance and Durability: ATheoretical Study
British Library Electronic Table of Contents (United Kingdom)
Abstract Hybrid power plants consisting of a solid oxide fuel cell (SOFC) and a gas turbine show high electrical efficiencies, however require pressurisation of the SOFC to several bar. This paper presents a theoretical investigation of the pressure influence on SOFC performance and durability. A two-dimensional elementary kinetic model is used to predict the performance of a single cell in the pressure range of 1-20-bar. The influence of pressure on thermodynamics, reaction kinetics, porous electrode diffusion, channel transport and efficiency is assessed. It was found that polarisation resistance decreases with increasing pressure due to increased diffusion through porous electrodes and a higher electrode surface coverage with reactant species. Furthermore, open-circuit voltage increases...
2011-01-01
Incorporation of organizational failures in PSA
International Nuclear Information System (INIS)
A large portion of the work performed at nuclear power plants follows standardized flow paths. For example, although components on which the maintenance crew works differ from one assignment to the next, all assignments basically follow the same process: requesting, reviewing, planning, scheduling, executing, testing, and documenting the work. In general, the term open-quotes work processclose quotes is used to refer to a standardized sequence of tasks designed within the operational environment of an organization to achieve a specific goal. The predictable nature of work processes suggests that a systematic analysis can be conducted to identify the desirable design of the process and to develop performance measures with respect to the strengths and weaknesses in the process. Furthermore, because of the close relationship of the work process to plant performance and plant safety, it is believed that such an analysis will ...
1993-06-20
British Library Electronic Table of Contents (United Kingdom)
A study was undertaken to assess the effect of different storage temperatures on senescence and postharvest performance of isolated flowers of Ranunculus asiaticus L.. The main aim of the work was to develop a cost-effective storage protocol to reduce the postharvest losses and to bring out the transportation of cut flowers of R. Asiaticus. The flowers were subjected to two different storage treatments, dry storage and wet storage, and their postharvest performance was compared under laboratory conditions. For this purpose, the buds were harvested at 8:00 AM at loose bud stage (Stage II of flower development). The harvested buds were cut to a uniform size of 15 cm and processed for dry or wet storage. For dry storage, the buds were packed after wrapping them in moistened filter papers and ...
2011-01-01
Computed Tomography of the spine in multiple myeloma
International Nuclear Information System (INIS)
Computed Tomography (CT) of the spine was performed on 17 patients with myeloma in order to assess the role of the technique in recognizing and evaluating the extent of the lesions. Myelomatous lesions followed two patterns at CT: first of all, multiple focal lesions, whose density is either solid, liquid, or fatty; second, an extensive pattern involving the spongiosa of the vertebra, including the posterior arch. CT detected more lesions than conventional radiology; furthermore, the extent of the lesions was much better demonstrated by CT. CT should thus be performed: a) in case of pain and/or neurological findings in negative radiological examinations; b) to evaluate the extent of myelomatous lesions (mainly in the spine); c) in solitary myeloma CT may be performed on different bone segments with clinical symptomatology but normal X-ray findings.
1988-01-01
An analytical framework for capacity development in EIA ? The case of Yemen
British Library Electronic Table of Contents (United Kingdom)
Most countries worldwide nowadays apply Environmental Assessment (EA) as an ex ante tool to evaluate environmental impacts of policies, plans, programmes, and projects. However, the application and performance of EA differ significantly. Scientific analysis of how EA performs mainly focuses on two levels: the micro (or project) level and the macro (or system) level. Macro level analysis usually focuses on institutions for EA and the organisation of stakeholder interaction in EA. This article proposes a more comprehensive framework for analysing EA systems that combines other approaches with a capacity approach and an explicit consideration of the context in which EA systems are developed and performed. In order to illustrate the value of our framework, we apply it to the Republic of Yemen,...
2010-01-01
International Nuclear Information System (INIS)
This paper presents a trial of probabilistic simulation for performance assessment of high-level waste (HLW) disposal using the Monte Carlo method. Based on the Reference Case conceptual model in H12, a new integrated simulation system which allowed us to rapidly evaluate the effect of data uncertainty was developed. The doses to hypothetical exposure group were compared with the results of H12 that were performed by using a point-wise approach, in terms of maximum total dose. This study showed that H12 results were consistent with results of probabilistic simulation and also showed that transmissivity had a strong influence for the uncertainty of the system performance in all simulation time. (author)
2000-12-01
International Nuclear Information System (INIS)
The Belgian radioactive waste management agency NIRAS/ONDRAF has undertaken a comparative assessment study on long-term waste management options for the high-level and/or long-lived radioactive waste that should be managed as a result of the use of nuclear energy in Belgium. This study is one of the supportive documents to a Strategic Environmental Assessment (SEA) process initiated end of 2008 and geared towards a decision in principle by the Belgian Government in 2010 on the long-term management of such radioactive waste. NIRAS/ONDRAF, together with Belgian and international research organisations, has developed a reference option for such high-level and long-lived radioactive waste, called Category B and C Waste, consisting of the disposal of such waste in a clay formation [SAFIR-2]. More than 30 years of R and D have been undertaken resulting, among others, in the underground research facility HADES, though the decision ...
2009-06-01
Energy Technology Data Exchange (ETDEWEB)
The proposed action is to recycle slightly activated copper that is currently stored in a warehouse leased by Lawrence Berkeley Laboratory (LBL) to a scrap metal dealer. Subsequent reutilization of the copper would be unrestricted. This document addresses the potential environmental effects of recycling and reutilizing the activated copper. In addition, the potential environmental effects of possible future uses by the dealer are addressed. Direct environmental effects from the proposed action are assessed, such as air emissions from reprocessing the activated copper, as well as indirect beneficial effects, such as averting air emissions that would result from mining and smelting an equivalent quantity of copper ore. Evaluation of the human health impacts of the proposed action focuses on the pertinent issues of radiological doses and protection of workers and the public. Five alternatives to the proposed action are considered, and their associated potential ...
1993-08-02
Energy Technology Data Exchange (ETDEWEB)
Previous analyses of binary cycles for conversion of geothermal energy from moderate temperature resources to electrical energy have shown potential gains in net geofluid effectiveness on the order of 8%, resulting from selection of turbine-expansion processes whose equilibrium states pass through the two-phase region. If condensation occurs, this gain could be reduced or eliminated by the resulting loss in turbine efficiency. Experience with many fluids, however, indicates that vapor supersaturation permits metastable pure-vapor states to exist at temperatures considerably below the saturation temperature at a given pressure; thus, by better understanding the condensation process, and properly structuring the cycle, substantial performance gains may be possible. The purpose of the present study was to assess the probability for attaining this performance gain by estimating the extent of condensation which might be expected ...
1983-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Aims: This study performed a systematic review and meta-analysis on glycemic control and pregnancy outcomes in women with type 1 diabetes mellitus (T1DM) treated with lispro (LP) versus regular insulin (RI) since before pregnancy. Methods: We performed a MEDLINE and EMBASE search. Abstracts (and full articles when appropriate) were reviewed by two independent researchers. Inclusion criteria were patients with T1DM, data on women treated with RI and LP since before pregnancy until delivery in the same article, at least five pregnancies in each group, and information on at least one pregnancy outcome. Quality assessment was performed using the Newcastle?Ottawa Quality Assessment Scale for cohort studies. Results: Outcome data were summarized with Revman version 5.0 (ims.cochrane.org...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The Superfund Amendments and Reauthorization Act of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) requires a Federal Facility Agreement (FFA) for federal facilities placed on the National Priorities List. The Oak Ridge Reservation was placed on that list on December 21, 1989, and the agreement was signed in November 1991 by the Department of Energy Oak Ridge Field Office (DOE-OR), the US Environmental Protection Agency (EPA)-Region IV, and the Tennessee Department of Environment and Conservation (TDEC). The effective date of the FFA was January 1, 1992. Section 9 and Appendix F of the agreement impose design and operating requirements on the Oak Ridge National Laboratory (ORNL) liquid low-level radioactive waste (LLLW) tank systems and identify several plans, schedules, and assessments that must be submitted to EPA/TDEC for review or approval. The initial issue of this document in March ...
1993-06-01
Analysis of enclosed sodium pool fire scenario in sodium fire experimental facility
International Nuclear Information System (INIS)
Liquid sodium is used as coolant in Fast Breeder Reactors (FBR). There is a likelyhood of sodium spillage in ambient air in the Steam Generator Building (SGB) of the FBR plant. Due to high chemical reactivity with oxygen, especially at temperatures greater than 573 K, it catches fire very easily. In order to carryout safety related experimental studies for different modes of sodium fires and to develop suitable mathematical models for the assessment of their consequences, an experimental facility (SFEF, Sodium Fire Experimental Facility) is being setup a IGCAR, Kalpakkam. The SFEF is having a 540 m"3 volume experimental hall. Stainless steel linear will be provided on the inside surfaces of experimental hall walls, ceiling and floor. Analysis has been carried out for enclosed sodium pool fire scenarios in SFEF by using sodium pool fire code SOFIRE II, which estimates the thermal transients like pressure rise, gas ...
2007-04-22
Summary of Information and Resources Related to Energy Use in Healthcare Facilities - Version 1
Energy Technology Data Exchange (ETDEWEB)
This document presents the results of a review of publicly available information on energy use in health care facilities. The information contained in this document and in the sources cited herein provides the background and context for efforts to reduce energy use and costs in health care. Recognizing the breadth and diversity of relevant information, the author acknowledges that the report is likely not comprehensive. It is intended only to present a broad picture of what is currently known about health care energy use. This review was conducted as part of a 'High Performance Health Care Buildings' research study funded by the California Energy Commission. The study was motivated by the recognition that health care facilities collectively account for a substantial fraction of total commercial building energy use, due in large part to the very high energy intensity of hospitals and other inpatient care ...
2009-09-08
D & D screening risk evaluation guidance
Energy Technology Data Exchange (ETDEWEB)
The Screening Risk Evaluation (SRE) guidance document is a set of guidelines provided for the uniform implementation of SREs performed on decontamination and decommissioning (D&D) facilities. Although this method has been developed for D&D facilities, it can be used for transition (EM-60) facilities as well. The SRE guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the current risk to human health and the environment, exterior to the building, from ongoing or probable releases within a one-year time period. The Worker Exposure Index (WEI) calculates the current risk to workers, occupants and visitors inside contaminated D&D ...
1995-09-01
Choice of energy data in environmental assessment of the built environment
Energy Technology Data Exchange (ETDEWEB)
Life cycle oriented methods are increasingly used for environmental assessments (EAs) of the built environment. However, many assumptions are made in such assessments, potentially influencing the results and making the assessment more ambiguous. To increase the reliability of EAs, consequences of the assumptions made have to be better understood. Since energy use in the operation and maintenance phase is an important factor decisive for the overall environmental performance of a building, the purpose of this study is to investigate how the selection of heat and electricity mix affects the assessed environmental performance of buildings. It also aims to suggest how to choose heat and electricity data in EAs of the built environment in general. Applying four different modes of electricity production and two different modes of heat production in a case study of ...
2003-03-01
Indian Academy of Sciences (India)
central server with search facility involving all partner journals ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to evaluate the ability to enhance distribution of eelgrass (Zostera marina) in the Columbia River Estuary to serve as refuge and feeding habitat for juvenile salmon, Dungeness crab, and other fish and wildlife. We strongly suspected that limited eelgrass seed dispersal has resulted in the present distribution of eelgrass meadows, and that there are other suitable places for eelgrass to survive and form functional meadows. Funded as part of the Bonneville Power Administration's call for Innovative Projects, we initiated a multistage study in 2008 that combined modeling, remote sensing, and field experimentation to: (1) Spatially predict habitat quality for eelgrass; (2) Conduct experimental plantings; and (3) Evaluate restoration potential. Baseline in-situ measurements and remote satellite observations were acquired for locations in the Lower Columbia River Estuary (LCRE) to determine ambient habitat conditions. These were used to create a ...
2009-09-08
Transuranic radionuclides dispersed into the environment at accident sites, a bibliography
Energy Technology Data Exchange (ETDEWEB)
The purpose of this project was to compile a bibliography of references containing environmental transuranic radionuclide data. The authors intent was to identify those parameters affecting transuranic radionuclide transport that may be generic and those that may be dependent on chemical form and/or environmental conditions. An understanding of the unique characteristics and similarities between source terms and environmental conditions relative to transuranic radionuclide transport and cycling will provide the ability to assess and predict the long term impact on man and the environment. An additional goal of the literature review, was to extract the ranges of environmental transuranic radionuclide data from the identified references for inclusion in a data base. Related to source term, these ranges of data can be used to calculate the dose to man from the radionuclides, and to perform uncertainty analyses on these dose ...
1994-07-01
Report of the technical committee meeting 1997 annual workshop on ASSET experience and feedback
International Nuclear Information System (INIS)
Papers and presentations were made by all participating countries and provided a wide range of perspectives on the use of the ASSET methodology. Generally, the views expressed were positive, however, there were comments on areas were the service could be improved or enhanced. The workshop was divided into three task groups to analyze the self-assessments conducted at Krsko NPP, Slovenia; Dukovany NPP, Czech Republic; and Balakovo NPP, Russian Federation. In addition, they were asked to comment on the recommendations on the ASSET service made by the Consultants' Meeting of 26-30 August 1996 on ''Performance of the IAEA programme on Operational Safety Services''. A presentation was made by Mr. B. Thomas to remind delegates of the ASSET methodologies, and Mr. V. Sivokon demonstrated the latest developments of computer software available for assisting in the plant Self-Assessment process. Refs, figs, tabs.
1997-06-24
Reliability-based robustness analysis for a Croatian sports hall
British Library Electronic Table of Contents (United Kingdom)
This paper presents a probabilistic approach for structural robustness assessment for a timber structure built a few years ago. The robustness analysis is based on a structural reliability based framework for robustness and a simplified mechanical system modelling of a timber truss system. A complex timber structure with a large number of failure modes is modelled with only a few dominant failure modes. First, a component based robustness analysis is performed based on the reliability indices of the remaining elements after the removal of selected critical elements. The robustness is expressed and evaluated by a robustness index. Next, the robustness is assessed using system reliability indices where the probabilistic failure model is modelled by a series system of parallel systems.
2011-01-01
Regional assessment of ambient volatile organic compounds from biopharmaceutical R&D complex
British Library Electronic Table of Contents (United Kingdom)
Biopharmaceutical R&D complexes are major emission sources of volatile organic compounds (VOCs), which may pose potential health risks for staff on site and residents nearby. In this paper health risk assessments were performed for the VOCs in the ambient air of a typical biopharmaceutical R&D complex in China. Results showed halogenated and alkyl compounds were dominant components among 24 major VOCs from 9 selected sampling sites, inside or around the complex. The principal component analysis (PCA) indicated VOCs were generated predominantly from the biopharmaceutical research activities (factor 1 (F1), 71.6%) and traffic vehicles (factor 2 (F2), 15.4%), which were confirmed by contour maps of five selected VOCs (benzene, toluene, chlorobenzene, methylene chloride and n-hexane) simulated...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Coumarin (1,2-benzopyrone) is occurring in food, and is also used in cosmetics. In order to perform a risk assessment for both oral and dermal exposure, we applied a physiologically based approach to model kinetics in humans by simulating both routes of exposure. The concentration-time profile in liver revealed a higher peak concentration (Cmax-hep) for the oral when compared to the dermal route. The area under the concentration-time curve in the liver (AUChep) was found the same for both routes if the same extent of absorption is assumed. Dose response information from published rat studies were used to identify the metric relevant for liver toxicity. Liver exposure levels resulting from doses and durations as outlined in the studies were simulated in a rat model. We obtained 31 data pair...
2011-01-01
PET and MRI in cardiac imaging: from validation studies to integrated applications
International Nuclear Information System (INIS)
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac ...
2009-03-01
Natural gas vehicles: Technical assessment and overview of world situation
International Nuclear Information System (INIS)
In evaluating commercialization prospects for natural gas fuelled vehicles, this paper compares the performance and emission quality of these innovative vehicles with those using conventional fuels - gasoline and diesel fuels. Assessments are made of the state-of-the-art of current technology relative to fuel storage, air/fuel mixture preparation, in cylinder combustion processes and pollution control. The analysis evidences that while natural gas is an excellent fuel for spark ignition engines, in transport applications its use is hampered by large storage volume requirements and weight. Moreover, the air/fuel mixture preparation, combustion process and exhaust-gas cleaning require a greater research and development effort to make this alternative fuel economically and environmentally competitive with conventional fuels.
1992-11-25
British Library Electronic Table of Contents (United Kingdom)
Background: Measurements from pressure biofeedback units (PBUs) can be used to evaluate the activity of the transversus abdominis (TrA) muscle indirectly. These measurements can classify patients or monitor the progress of treatment programmes for people with low back pain. Objective: To systematically review studies on the measurement properties of PBUs for the assessment of TrA activity. Data sources: Eligible studies were identified through searches of PUBMED, CINAHL and BIREME (1990 to 2009). In addition, hand searches of journals and citation tracking were performed. Study selection: Full-text studies involving any type of clinimetric tests of PBU measurement for the assessment of TrA activity were selected. Data extraction: Two independent reviewers selected the studies, extracted th...
2011-01-01
Life cycle assessment of electric mobility: answers and challenges?Zurich, April 6, 2011
British Library Electronic Table of Contents (United Kingdom)
Introduction Alternative ways and means of transportation are necessary in order to reduce the environmental impacts of mobility. In the recent years, biofuels were first seen as a main option and then LCA showed also possible hazards of this development. Recently, public interest is rapidly shifting towards electromobility. Therefore it is necessary to also gain better knowledge about the environmental impacts of this technology. This includes a modelling of the pathways of the necessary increase in electricity supply and an appropriate modelling of battery manufacture. Summary of data presented At this forum most recent results of life cycle assessment studies of electric car driving compared to driving fossil- and agro-fuelled cars were presented. The environmental performance of indivi...
2011-01-01
Joint shear strength of FRP reinforced concrete beam-column joints
British Library Electronic Table of Contents (United Kingdom)
An assessment of the joint shear strength of exterior concrete beam-column joints reinforced internally with Glass Fibre Reinforced Polymer (GFRP) reinforcements under monotonically increasing load on beams keeping constant load on columns is carried out in this study. Totally eighteen numbers of specimens are cast and tested for different parametric conditions like beam longitudinal reinforcement ratio, concrete strength, column reinforcement ratio, joint aspect ratio and influence of the joint stirrups at the joint. Also finite element analysis is performed to simulate the behaviour of the beam-column joints under various parametric conditions. Based on this study, a modified design equation is proposed for assessing the joint shear strength of the GFRP reinforced beam-column specimens b...
2011-01-01
Insitu Assessment of Contaminant Containment Systems
Environmental Research Database
Objectives(1) Evaluate various insitu techniques for determination of the permeability of slurry walls and investigate the extent of material disturbance and fracturing during drilling and testing.~%~~%~(2) Perform laboratory tests of block samples obtained from the field testing site and compare the results with field measurements.~%~~%~(3) Investigate the mechanisms of drilling using a newly developed instrumented self-boring device and develop a theoretical framework for drilling mechanisms in soils.~% [continued...]DescriptionCement-bentonite and clay liner systems are used as components of containment systems by the environmental industry to control the migration of pollution. In the interest of public safety, following construction, there is a requirement to test these structures in orde to assess if they meet the design critetia. At present this is done only indirectly via laboratory testing on samples ...
2006-01-30
Human reliability analysis in Wolsung 2/3/4 nuclear power plants probabilistic safety assessment
Energy Technology Data Exchange (ETDEWEB)
The Level 1 probabilistic safety assessment (PSA) for Wolsung(WS) 2/3/4 nuclear power plant (NPPs) in design stage is performed using the methodologies being equivalent to PWR PSA. Accident sequence evaluation program (ASEP) human reliability analysis (HRA) procedure and technique for human error rate prediction (THERR) are used in HRA of WS 2/3/4 NPPs PSA. The= purpose of this paper is to introduce the procedure and methodology of HRA in WS 2/3/4 NPPs PSA. Also, this paper describes the interim results of importance analysis for human actions modeled in WS 2/3/4 PSA and the findings and recommendations of administrative control of secondary control area from the view of human factors. (Author) 10 refs., 2 tabs.
1997-05-01
Human reliability analysis in Wolsong 2/3/4 nuclear power plants probabilistic safety assessment
International Nuclear Information System (INIS)
The Level 1 probabilistic safety assessment (PSA) for Wolsong(WS) 2/3/4 nuclear power plant(NPPs) in design stage is performed using the methodologies being equivalent to PWR PSA. Accident sequence evaluation program (ASEF) human reliability analysis (HRA) procedure and technique for human error rate prediction (THERP) are used in HRA of WS 2/3/4 NPPs PSA. The purpose of this paper is to introduce the procedure and methodology of HRA in WS 2/3/4 NPPs PSA. Also, this paper describes the interim results of importance analysis for human actions modeled in WS 2/3/4 PSA and the findings and recommendations of administrative control of secondary control area from the view of human factors.
1997-05-01
Draft Regulatory Rule-making for On-line Maintenance of Nuclear Power Plants
International Nuclear Information System (INIS)
Internationally, on-line maintenance (OLM) of nuclear power plants under the operation is prevailed to enhance nuclear safety and economics. In recent years, Korea Hydro and Nuclear Power Co. Ltd. (KHNP) is eager to apply OLM. Ministry of Education, Science and Technology (MEST) has established the related technology development program as an item of 'Overall Planning on Nuclear Safety(2010-2014)' through acceptance to the request of KHNP in 2009. OLM is defined as maintenance that is performed with the main generator connected to the grid. In other words, it means a preventive maintenance to be implemented during the allowable outage time (AOT) with ignoring inoperability of safety-related equipment listed in the technical specifications. The Korea Institute of Nuclear Safety (KINS) is developing the assessment technology of safety concerns for OLM under the auspices of MEST. Draft regulatory rule-making for OLM is devised as a part of the ...
2010-10-01
Assessing potential impacts of climatic change on subalpine forests on the eastern Tibetan Plateau
British Library Electronic Table of Contents (United Kingdom)
Forest gap models have been used widely in the study of forest dynamics, including predicting long-term succession patterns and assessing the potential impacts of climate change on forest structure and composition. However, little effort is devoted to predict forest dynamics in the high elevation areas, although they have the sensitive response to global climate change. In the present study, based on a modified height-diameter function, we developed a new version (FAREAST-GFSM) of the forest patch model, FAREAST for simulating the changes of subalpine forests. The observed data from the Gongga Mt. Alpine Station were also used to test model precision. With the improved performance of FAREAST-GFSM, we explored the impact of three warming scenarios on subalpine forest on the eastern Tibetan ...
2011-01-01
A hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating transportation service quality
British Library Electronic Table of Contents (United Kingdom)
Managing service quality is vital to retain customer satisfaction and augment revenues for any business organization. Often it is difficult to assess service quality due to lack of quantifiable measures and limited data. In this paper, we present a hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating service quality of urban transportation systems. The proposed approach consists of three steps. The first step involves development of a SERVQUAL based questionnaire to collect data for measuring transportation service quality. The participants provide linguistic assessments to rate the service quality criteria and the alternatives. In step 2, the linguistic ratings are combined through fuzzy TOPSIS to generate an overall performance score for each alternative. The alternative wit...
2011-01-01
International Nuclear Information System (INIS)
A comparative assessment of five different heat transfer configurations for operation in compact heat exchangers is presented. The configurations under consideration are four standaed heat exchanger surfaces - two plain fin, an offset strip and a louvered fin geometry - and one surface with so called vortex generators for heat transfer augmentation. In the case of the standard surfaces, the basic performance characteristics in the form of heat transfer and friction data versus the Reynolds number have been taken from published experimental results. In the case of the vortex generator surface, the performance characteristics have been derived from a numerical prediction of the flow and temperature field in a closely spaced parallel plate channel with vortex generators in the form of delta wings mounted on the channel walls. In comparison to the plain fin surfaces with a rectangular cross section, the vortex generator surface ...
1993-01-01
Performance characterization of a volumetric breast ultrasound scanner
The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and ...
2007-03-01
International Nuclear Information System (INIS)
Due to current social and economical framework, in last years many nuclear power plant owners started a program for the Long Term Operation (LTO)/PLIM (Plant Life Management) of their older nuclear facilities. PLIM/PLEX has already been implemented in many countries (USA, Russia, etc.). This process has many nuclear safety implications, other than strategic and political ones. The need for tailoring the available safety assessment tools to such applications has become urgent in recent years and triggered many research actions. In particular, a PLIM framework requires both a detailed review of the features of the main safety programs (Maintenance, ISI, Surveillance) and a complete integration of these programs into the general management system of the plant. New external factors, such as: large use of subcontractors, need for efficient management of spare parts, request for heavy plant refurbishment programs demand for updated techniques in the ...
2007-10-15
This report presents the operating results for Run 245 at the Advanced Coal Liquefaction R and D Facility in Wilsonville, Alabama. This run was made in an all-distillate Integrated Two-Stage Liquefaction (ITSL) mode using Illinois 6 coal from the Burning Star mine. The primary run objective was to obtain steady-state ITSL performance by replacing spent HTR reactor catalyst with fresh, sulfided catalyst. Secondary objectives were to maintain an all-distillate (minimum resid production) product slate and to demonstrate the effects of catalyst addition on the net gas production and hydrogen consumption. Run 245 began on 7 November, 1983, and continued through 12 February, 1984. During this period, 179.0 tons of coal was fed in 2045 hours of operation. Eight special product workup material balances were defined, and the results are presented herein. 6 references, 28 figures, 20 tables.
1984-10-01
Verification of maximum impact force for interim storage cask for the Fast Flux Testing Facility
Energy Technology Data Exchange (ETDEWEB)
The objective of this paper is to perform an impact analysis of the Interim Storage Cask (ISC) of the Fast Flux Test Facility (FFTF) for a 4-ft end drop. The ISC is a concrete cask used to store spent nuclear fuels. The analysis is to justify the impact force calculated by General Atomics (General Atomics, 1994) using the ILMOD computer code. ILMOD determines the maximum force developed by the concrete crushing which occurs when the drop energy has been absorbed. The maximum force, multiplied by the dynamic load factor (DLF), was used to determine the maximum g-level on the cask during a 4-ft end drop accident onto the heavily reinforced FFTF Reactor Service Building`s concrete surface. For the analysis, this surface was assumed to be unyielding and the cask absorbed all the drop energy. This conservative assumption simplified the modeling used to qualify the cask`s structural integrity for this accident condition.
1996-06-01
International Nuclear Information System (INIS)
This paper presents actual time/motion data for an oversize truck spent-fuel shipment from its origin, Surry, Virginia to its destination, Idaho National Engineering Laboratory (INEL). These data include the receipt of the empty cask at the reactor, wet-loading the cask, over-the-road or in-transit data, and receipt and dry unloading of the shipping cask at the receiving facility. Occupational doses were recorded at the Surry Power Plant as well as at INEL, and public doses were calculated for the in-transit dose analysis. This shipment was one of a series performed in support of a demonstration and evaluation of dry storage at INEL. The oversized shipment consisted of a TN-8L shipping cask loaded with three 10-yr-old pressurized water reactor assemblies. The total distance traveled was #approx#2800 miles, requiring 62 h including stops. The time required to receive and inspect the empty shipping cask and wet-load and release the shipment at ...
1988-11-04
Status Report of Simulated Space Radiation Environment Facility
Energy Technology Data Exchange (ETDEWEB)
The technology for performance testing and improvement of materials which are durable at space environment is a military related technology and veiled and securely regulated in advanced countries such as US and Russia. This core technology cannot be easily transferred to other country too. Therefore, this technology is the most fundamental and necessary research area for the successful establishment of space environment system. Since the task for evaluating the effects of space materials and components by space radiation plays important role in satellite lifetime extension and running failure percentage decrease, it is necessary to establish simulated space radiation facility and systematic testing procedure. This report has dealt with the status of the technology to enable the simulation of space environment effects, including the effect of space radiation on space materials. This information such as the fundamental knowledge of space ...
2007-11-15
Power Systems Development Facility Gasification Test Campaign TC17
Energy Technology Data Exchange (ETDEWEB)
In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR (formerly Kellogg Brown & Root) Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results gasification operation with Illinois Basin bituminous coal in PSDF test campaign TC17. The test campaign was completed from October 25, 2004, to November 18, 2004. System startup and initial operation was accomplished with Powder River Basin (PRB) subbituminous coal, and then the system was transitioned to Illinois Basin coal operation. The major objective for this test ...
2004-11-30
NATIONAL HIGH MAGENTIC FIELD LABORATORY FEL INJECTOR DESIGN CONSIDERATION
Energy Technology Data Exchange (ETDEWEB)
A Numerical study of beam dynamics was performed for two injector systems for the proposed National High Magnetic Field Laboratory at the Florida State University (FSU) Free Electron Laser (FEL) facility. The first considered a system consisting of a thermionic DC gun, two buncher cavities operated at 260 MHz and 1.3 GHz and two TESLA type cavities, and is very similar to the injector of the ELBE Radiation Source. The second system we studied uses a DC photogun (a copy of JLab FEL electron gun), one buncher cavity operated at 1.3 GHz and two TESLA type cavities. The study is based on PARMELA simulations and takes into account operational experience of both the JLab FEL and the Radiation Source ELBE. The simulations predict the second system will have a much smaller longitudinal emittance. For this reason the DC photo gun based injector is preferred for the proposed FSU FEL facility.
2007-06-25
Measures for reliability improvement of on-site power plant at steel works
Energy Technology Data Exchange (ETDEWEB)
This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in separate sections of the ...
1988-04-15
Energy Technology Data Exchange (ETDEWEB)
Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank systems, this framework requires the specified plans and schedules be submitted to EPA and TDEC for ...
1992-03-01
Fast Flux Test Facility reactor initial criticality predictions and measurements
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) was designed to test fast-reactor fuels and other nonfuel materials. In its 37 reactor cycles of operations, the FFTF reactor has performed very well and successfully completed all the irradiation testings with an operating efficiency factor as high as 98%. Since FFTF is an experimental reactor, its core loading changed from cycle to cycle. Depending on the number of test assemblies in the core and their location, the core loading can change significantly from an essentially homogeneous core loading to a relatively nonhomogeneous or even highly localized heterogeneous loading. Consequently, the core reload design and initial criticality analyses were required for each operating cycle. The zero power initial critical control rod bank height was predicted before each reactor startup. The initial critical prediction depends on the reactivity conditions at the end of the previous cycle, the temperature feedback ...
1992-06-07
FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling operations must be ...
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
Previous laboratory tests of elastomer O-rings in coal liquefaction solvents conducted at L'Garde, Inc., indicated that certain ethylenepropylenediene monomer (EPDM) compounds provided the best performance when a backup ring was used to limit swelling. Before service testing in a pump at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility, tests of six selected elastomers in the appropriate Wilsonville-produced solvent were conducted at Oak Ridge National Laboratory (ORNL). The ORNL tests measured the elastomers' changes in cross section, weight, density, and relative flexibility. Although two perfluoroelastomers showed less degradation of most properties during these tests, it was decided to proceed with service testing of two EPDM elastomers because of their much lower cost. 5 refs., 14 figs., 7 tabs.
1986-08-01
Drop Test of the Candu Spent Fuel Storage Basket in MACSTOR/KN-400
International Nuclear Information System (INIS)
The MACSTOR/KN-400 of Wolsung power plant in Korea is a dry interim storage facilities. There are 400 long slender cylinders in MACSTOR/KN-400. In one cylinder, ten baskets where Candu spent fuels are loaded are stacked and stored. For this MACSTOR/KN-400 facilities, analyses and tests for the hypothetical accident conditions that might happen during moving and storing baskets into a cylinder were performed. The hypothetical accident conditions to be considered are two cases. One is the case of basket dropping onto the bottom plate of a cylinder. The other is the case of basket dropping onto the other basket top plate stored in the cylinder. For the drop analyses, the case of hanging cylinder and the case of cylinder on the unyielding target surface were considered. Based on the dropping analysis, testing condition was determined as the latter case that is for the cylinder on the target surface. In a basket, 60 dummy fuel ...
2009-06-01
Development of real time personal neutron dosimeter with two silicon detectors
Energy Technology Data Exchange (ETDEWEB)
The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)
1997-07-01
Design experience of the JRR-2 BNCT facility in JAERI
Energy Technology Data Exchange (ETDEWEB)
The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the decay of thermal neutron. After the improvements, medical irradiation treatments have ...
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards however provide only conceptual definitions and requirements in the seismic related ...
2005-04-15
CFD Analysis of a Dry Storage System for MACSTOR/KN-400
International Nuclear Information System (INIS)
There are four nuclear power plants in operation at Wolsong and, annually, more than 5,000 assemblies of spent nuclear fuels are released from each plant. Thus the concrete silo type dry storage system was constructed from '90. However, after 2006, another dry storage facility is required to accept the all amount of spent nuclear fuels from the plants. Instead of the concrete silo type, MACSTOR/KN-400 was developed to store the CANDU spent nuclear fuel more densely. In this study, computational fluid dynamics (CFD) analysis of the MACSTOR/KN-400 model was performed to confirm the thermal integrity of the facility, especially for the concrete structure, using the commercial CFD code, FLUENT. The MACSTOR/KN-400 which has Thermal Insulation Panel (TIP) and IAEA Re-verification Pipe (RVP) was modeled and analyzed in the view point of the thermal integrity of the concrete structure.
2007-10-01
Light Infantry Division Assessment
... LIGHT INFANTRY DIVISION ASSESSMENT LOl 0 BY ... TYPE OF REPORT & PERIOD COVERED LIGHT INFANTRY DIVISION ASSESSMENT ...
1990-04-02
Energy Technology Data Exchange (ETDEWEB)
The primary objectives of this study were to test two utility analysis models, the Cascio-Ramos Estimate of Performance in Dollars (CREPID) model and Godkewitsch financial utility analysis model and to determine their appropriateness as tools for evaluating training. This study was conducted in conjunction with Philadelphia Electric Company's Nuclear Training Group. Job performance of nuclear maintenance workers was assessed to document the impact of the training program. Assessment of job performance covered six job performance themes. Additionally, front-line nuclear maintenance supervisors were interviewed to determine their perceptions of the nuclear maintenance training. A comparison of supervisor's perceptions and outcomes of the utility analysis models was made to determine the appropriateness of utility analysis as quantitative tools ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
LEDF(Large Equipment Dismantling Facility) is the solid waste processing technology development facility that carries out high-volume reduction and low dosage processing. The high-volume reduction processing of the high dose {alpha}-waste configured with combustible waste, pvc and rubber, spent ion exchange resin, and noncombustible waste have been planned the incinerating and melting facility using the in-can type high frequency induction heating in LEDF. This test is intended to clarify the design data. It was confirmed that the incinerating and melting performance, molten solid properties and exhaust gas processing performance with pilot testing equipment and bench scale equipment. The result of this test are as follows. 1. Processing speed is 6.7 kg/h for the combustible waste, 13.0 kg/h for the ion exchange resin, and 30.0 kg/h for the noncombustible waste. For above optimum ...
1999-12-01
Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel
Energy Technology Data Exchange (ETDEWEB)
The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy ...
2009-06-15
Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel
International Nuclear Information System (INIS)
The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy ...
2009-06-01
Preliminary assessment of future refining impacts of the Clean Air Act Amendments of 1990
Energy Technology Data Exchange (ETDEWEB)
A preliminary assessment of the future refining impacts of the Clean Air Act Amendments of 1990 has been performed with the Navy Mobility Fuels Forecasting Systems. The assessment suggests that gasoline reformulation costs in domestic coastal and near-coastal refining regions in the year 2000 could be 3.5 to 5.6 cents per gallon (in terms of 1989 currency). For heating value equivalent to one gallon of conventional gasoline, the regional total added costs (including reformulation costs) for reformulated gasoline could be 5.9 to 8.0 cents. In blending reformulated gasolines, the reduction of butane for lower Reid vapor pressure and the reduction of reformate for lower aromatics are generally compensated by increased percentages of alkylate and/or straight run naphthas. Relatively larger refinery process capacity additions are required for butane isomerization, alkylation, aromatics recovery, and distillate hydrotreating. 21 ...
1991-09-01
Energy Technology Data Exchange (ETDEWEB)
The contamination of environmental materials (soil and dust) by heavy elements is of concern in assessing environmental pollution. Characterization of samples is performed in order to provide information that can be used to assess the potential hazard of the material, to assess remediation strategies, and to determine the source of the heavy element-bearing material. Microbeam analysis using a scanning electron microscope (SEM) or electron microprobe on polished particle mounts allows the size, internal morphology and chemical composition to be determined on a particle-by-particle basis. Computer controlled SEM allows all factors except internal structure to be acquired in an automated fashion. The authors present examples of two studies using microbeam techniques. In the first example, they illustrate how cadmium associated with sphalerite in soils can be quantified at levels down to a few parts per ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Attention deficit hyperactivity disorder (ADHD) is known as a psychiatric disorder in childhood associated with dopamine dysregulation. We investigated dopamine transporter (DAT) density in children with ADHD in the present study using {sup 123}I-IPT SPECT and postulated that an alteration in DAT density in the basal ganglia (BG) is responsible for dopaminergic dysfunction in children with ADHD. 9 durg-naive children with ADHD and 6 normal children were included in the study. We performed brain SPECT 2 hours after administration of {sup 123}I-IPT and made both quantitative and qualitative analyses for assessment of specific/nonspecific DAT binding ratio in the BG. We investigated the correlation between the severity scores of ADHD symptoms in children with ADHD assessed with ADHD rating scale and specific/nonspecific DAT binding ratio in the BG. Drug-naive children with ADHD showed a significantly incresed ...
2002-07-01
The effects of surface damage on RF cavity operation
Energy Technology Data Exchange (ETDEWEB)
We describe a model of damage in rf cavities and show how this damage can limit cavity operation. We first present a review of mechanisms that may or may not affect the ultimate fields that can be obtained in rf cavities, assuming that mechanical stress explains the triggers of rf breakdown events. We present a method of quantifying the surface damage caused by breakdown events in terms of the spectrum of field enhancement factors, Beta, for asperities on the surface. We then model an equilibrium that can develop between damage and conditioning effects, and show how this equilibrium can determine cavity performance and show experimental evidence for this mechanism. We define three functions that quantify damage, and explain how the parameters that determine this performance can be factored out and measured. We then show how this model can quantitatively explain the dependence of cavity performance on material, frequency, ...
2006-04-14
Energy Technology Data Exchange (ETDEWEB)
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the interferometric microscope. ...
2005-07-12
Energy Technology Data Exchange (ETDEWEB)
The consistency of different instruments and methods for measuring two-dimensional (2D) power spectral density (PSD) distributions are investigated. The instruments are an interferometric microscope, an atomic force microscope (AFM) and the X-ray Reflectivity and Scattering experimental facility, all available at Lawrence Berkeley National Laboratory. The measurements were performed with a gold-coated mirror with a highly polished stainless steel substrate. It was shown that these three techniques provide essentially consistent results. For the stainless steel mirror, an envelope over all measured PSD distributions can be described with an inverse power-law PSD function. It is also shown that the measurements can be corrected for the specific spatial frequency dependent systematic errors of the instruments. The AFM and the X-ray scattering measurements were used to determine the modulation transfer function of the interferometric microscope. ...
2005-04-17
Safety performance indicators. Topical issues paper no. 5
International Nuclear Information System (INIS)
Since its creation the nuclear industry has been struggling with the question of how safe is safe enough. Safety is a common goal to all involved in the design, operation and regulation of a nuclear installation. As a concept safety is not easy to define. However, there is a general understanding of what attributes a nuclear power plant should have in order to operate safely. The challenge lies in measuring the attributes. The new competitive open electricity market, in many countries throughout the world, is increasing the economic pressure on operators to lower operating costs without jeopardizing safety. Challenges are occurring at a rate that is unprecedented in the nuclear industry: competitiveness; downsizing; ageing; policy changes; reorganization; restructuring; mergers; globalization; and takeovers demand increasing attention to the management of safety. There are various means to measure safety performance, some of which are more qualitative in nature and ...
2001-09-03
Pipeline risk assessment and risk management
Energy Technology Data Exchange (ETDEWEB)
The objective of this work group was to identify obstacles to the development of better risk management practices and performance standards in the pipeline industry. An outline of developments in pipeline risk assesment management was presented, including an update of the Risk Based Design and Assessment annex and other CSA Z662 code developments. It was suggested that progress in risk management require that acceptable levels of risk and reliability need to be defined. Environmental and safety consequence analysis was recommended, as well as failure frequency estimation and assessment of distribution systems. Guidelines for Integrity Management Programs (IMPs) were reviewed. It was noted that CSA Z662 will become mandatory for sour gas in 2005 and may become mandatory for all onshore pipelines in 2007. Operating company procedures in relation to hazards with significant consequences were discussed. It was noted that ...
2005-07-01
Vascular plants of the Hanford Site
Energy Technology Data Exchange (ETDEWEB)
An updated listing of the vascular plants of the Hanford Site is provided, along with discussions of how humans may interact with local plants and have influenced the regional flora. Based on examinations of herbarium collections at the Westinghouse Hanford Company, Pacific Northwest Laboratory, Washington State University, and Brigham Young University, 590 vascular plant species have been identified on or near the Hanford Site. This is more than twice the number of species on previously published lists of Hanford Site vascular plants. A review of the plant species that are currently listed as endangered, threatened, sensitive, or otherwise of concern to the Washington State Natural Heritage Program and the Federal Fish and Wildlife Service is included. Color photographs of selected species are included to aid identification. Lists are provided of the Hanford Site plant species that could be used as food and medicinal sources and of those introduced to the region through human ...
1992-07-01
The dependence of radiation hardening and embrittlement on irradiation temperature
International Nuclear Information System (INIS)
Assessments of the hardening and embrittlement of pressure vessel steels and welds as a function of neutron dose use trend curves derived from surveillance programs and accelerated irradiation data. A temperature dependent factor is incorporated for assessing vessel locations operating at different temperatures. As hardening and embrittlement arise from the sum of matrix damage and copper impurity precipitation, the influence of irradiation temperature on each process needs to be established. For irradiations performed below #approx# 300 C recent data shows that the dose-dependent growth of copper precipitates ceases at a mean diameter of about 2 nm that also corresponds to peak hardening and embrittlement by copper. For doses beyond this peak copper dose the property-dependence on irradiation temperature can be identified with that of matrix damage alone. An analysis of several experiments on plate steels, ...
1994-06-20
Quantitative assessment of bone scintigraphy in the hip joint disease
International Nuclear Information System (INIS)
Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be ...
Energy Technology Data Exchange (ETDEWEB)
Waste form dissolution studies and preliminary performance analyses were carried out to contribute a part of the data needed for the selection of a waste form for the disposal of Savannah River Plant defense waste in a deep geologic repository. The first portion of this work provides descriptions of the chemical interactions between the waste form and the geologic environment. We reviewed critically the dissolution/leaching data for borosilicate glass and SYNROC. Both chemical kinetic and thermodynamic models were developed to describe the dissolution process of these candidate waste forms so as to establish a fundamental basis for interpretation of experimental data and to provide directions for future experiments. The complementary second portion of this work is an assessment of the impacts of alternate waste forms upon the consequences of disposal in various proposed geological media. Employing systems analysis methodology, we began to ...
1981-07-01
International Nuclear Information System (INIS)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is: (1) conduct HELP model variations in weather data, profile characteristics, and hydraulic conductivities for major rock units; (2) compare and contrast the results of simulations; (3) obtain an estimation of leakage through the landfill from the surface to the aquifer; and (4) evaluate contaminant transport to the aquifer utilizing leakage estimation. The conclusions of this paper are: (1) the HELP model is useful to assess landfill design alternatives or the performance of a pre-existing landfill; (2) model results using site-specific data incorporated into the Weather Generator (Trail 4), varied significantly from generalized runs (Trials 1-3), consequently, models that lack site-specific data should be used cautiously; and (3) data from this study suggest that there will not be significant downward percolation of leachate from the surface of the landfill cap to the aquifer-leachate transport rates have been ...
2002-01-01
Geometry optimization of Fresnel-collectors with economic assessment
Energy Technology Data Exchange (ETDEWEB)
The Fresnel solar collector is a promising concept to reduce the electricity cost price in solar thermal power plants. The optical performance of a Fresnel collector depends on material properties, on its geometric layout and on the level of optical accuracy that can be obtained. A variety of geometric parameters, e.g. the height of the absorber, the number, size and distance of primary mirrors in.uence the shading and blocking of rays and the amount of rays missing the absorber. To evaluate the in.uence of the parameter variation regarding the electricity cost price and to yield an optimization, the optical performance is assessed with an annual simulation based on hourly weather-data. To permit a consideration of changes in collector cost according to different geometric layouts, cost factors where allocated to geometric parameters. The paper presents the method and the simulation results of the optimization under ...
2004-07-01
Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review
Energy Technology Data Exchange (ETDEWEB)
The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling devices and buildings. The studies related ...
2010-08-15
British Library Electronic Table of Contents (United Kingdom)
Summary Background Systematic screening for liver fibrosis in heavy-drinking patients is a challenge. Aims To assess Fibroscan for non-invasive diagnosis of asymptomatic liver fibrosis in alcohol abuse patients, to determine diagnostic liver stiffness cut-off values and to compare performance of Fibroscan with seven non-invasive laboratory tests. Methods One hundred and three alcoholic patients were studied. Liver fibrosis was staged by METAVIR system. Fibroscan, Fibrotest, Fibrometer, Hepascore, APRI, PGA, PGAA and hyaluronic acid tests were performed. Liver stiffness cut-offs were determined using receiver-operating characteristic (ROC) curves. Results Liver stiffness was correlated with fibrosis (r = 0.72, P < 0.014), with median at 5.7, 6.3, 8.4, 15 and 47.3 kPa for F0 (n = 8), F1 (n =...
2008-01-01
Ageing assessments with application of PSA Models
International Nuclear Information System (INIS)
One of the main applications of PSA studies is related to identification of the major key issues related to plant safety. In standard PSA one assumes a constant value for component failure rates by considering that the component doesn't experience any degradation that could affect its performance. Used in this manner, standard PSA tools do not adequately address important ageing issues, and this fact could have a significant impact on the conclusions drawn from PSA studies and applications, in conditions of operation of ageing plants. To obtain realistic results, it is necessary to consider in the PSA model the ageing effects, and to do that it is necessary to take into consideration the change in component failure rate as a function of component age. In case of ageing phenomena, this dependence causes the failure rate of a component (or a set of components) to increase in time as the component age increase. The paper presents the benefits of ...
2009-10-12
Energy Technology Data Exchange (ETDEWEB)
The Subcommittee for Surveillance of Nuclear Medicine Practice has implemented a survey for actual nuclear medicine practice in Japan every 5 years. This article reports on the third survey implemented during a one-month period in June 1992. Questionnaires were sent to all 1256 facilities employing radiopharmaceuticals in routine practice, and 1162 (92.5%) answered. In vivo nuclear medicine examinations per day were performed in 6600 cases. SPECT accounted for 19.4%, as compared with 7.1% in the 1987 survey. According to organs, the frequency of examination for the cerebrospinal region was 3.2 and 2.2 times higher than that in the 1982 and 1987 surveys, respectively, whereas for the thyroid gland it was 0.6-fold and 0.7-fold that of these surveys. The proportion of bone scintigraphy was the highest (24.5%), followed by tumor scintigraphy (14.1%) and myocardial scintigraphy (11.9%). The frequency of myocardial and cerebral blood flow ...
1993-09-01
Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test
Energy Technology Data Exchange (ETDEWEB)
The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring ...
1999-03-01
International Nuclear Information System (INIS)
Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be obtained with this fluid, and (ii) some existing facilities already used surrogate fluids, which in general have lower critical ...
2005-10-02
Energy Technology Data Exchange (ETDEWEB)
Volume VII of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the tritium transport model documentation. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
Volume VI of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the groundwater flow model data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
1996-11-01
Energy Technology Data Exchange (ETDEWEB)
Volume IV of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the hydrologic parameter data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
Volume II of the documentation for the Phase I Data Analysis Task performed in support of the current Regional Flow Model, Transport Model, and Risk Assessment for the Nevada Test Site Underground Test Area Subproject contains the potentiometric data. Because of the size and complexity of the model area, a considerable quantity of data was collected and analyzed in support of the modeling efforts. The data analysis task was consequently broken into eight subtasks, and descriptions of each subtask's activities are contained in one of the eight volumes that comprise the Phase I Data Analysis Documentation.
1996-12-01
Predicting the efficiency of activated charcoal for filtering radon
Energy Technology Data Exchange (ETDEWEB)
In order to accurately assess the effectiveness of activated charcoal for the removal of radon from flowing air, a literature survey was performed to identify the models and relevant data that were available. It was found that by modifying the mathematical model of equilibrium stage theory used by Strong and Levins, the output rate of an activated charcoal filter exposed to a step function input in the radon rate at time zero with a given carrier gas flow velocity could be predicted. This paper outlines the modifications made to Strong and Levins's model and presents predictions for the filter output from the modified model.
1993-01-01
Health effects[1997 Scientific Report of the Belgian Nuclear Research Centre
Energy Technology Data Exchange (ETDEWEB)
The objectives of the research in the field of epidemiology , performed at the Belgian Nuclear Research Centre SCK-CEN are (1) to study cancer mortality and morbidity in nuclear workers in Belgium; (2) to document the feasibility of retrospective cohort studies in Belgium; (3) to participate in the IARC study. For radiobiology, the main objectives are: (1) to elucidate the mechanisms of the effects of ionizing radiation on the mammalian embryo during the early phase of its development, (2) to assess the genetic risks of maternal exposure to ionizing radiation, (3) to elucidate the mechanisms by which damage to the brain and mental retardation are caused in man after prenatal irradiation. The main achievements in these domains for 1997 are presented.
1998-07-01
Full-length fuel rod behavior under severe accident conditions
Energy Technology Data Exchange (ETDEWEB)
This document presents an assessment of the severe accident phenomena observed from four Full-Length High-Temperature (FLHT) tests that were performed by the Pacific Northwest Laboratory (PNL) in the National Research Universal (NRU) reactor at Chalk River, Ontario, Canada. These tests were conducted for the US Nuclear Regulatory Commission (NRC) as part of the Severe Accident Research Program. The objectives of the test were to simulate conditions and provide information on the behavior of full-length fuel rods during hypothetical, small-break, loss-of-coolant severe accidents, in commercial light water reactors.
1992-12-01
A New Fuzzy MCDM Framework to Evaluate E-Government Security Strategy
Ensuring security of e-government applications and infrastructures is crucial to maintain trust among stakeholders to store, process and exchange information over the e-government systems. Due to dynamic and continuous threats on e-government information security, policy makers need to perform evaluation on existing information security strategy as to deliver trusted e-government services. This paper presents an information security evaluation framework based on new fuzzy multi criteria decision making (MCDM) to help policy makers conduct comprehensive assessment of e-government security strategy.
2010-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.