The high-purity-oxygen activated sludge process will be used to expand secondary treatment capacity and improve water quality in Santa Monica Bay. The facility is operated by the city of Los Angeles Department of Public Works` Bureau of Sanitation. The overall Hyperion Full Secondary Project is 30% complete, including a new headworks, a new primary clarifier battery, an electrical switch yard, and additional support facilities. The upgrading of secondary facilities is 50% complete, and construction of the digester facilities, the waste-activated sludge thickening facility, and the second phase of the three-phase modification to existing primary clarifier batteries has just begun. The expansion program will provide a maximum monthly design capacity of 19,723 L/s(450 mgd). Hyperion`s expansion program uses industrial treatment techniques rarely attempted in a municipal ...
This sheet summarizes information on geothermal heat pumps (GHPs), which extracts heat from the ground in the winter and transfers heat to the ground in the summer. More than 200,000 GHPs are operating in US; they can reduce energy consumption and related emissions by 23 to 44% compared to air-source heat pumps. Opportunities for use of GHPs, requirements, and cost are described. Important terms are defined.
The Zaafarana oilfield development, operated by Zaafarana Oil Co. (Zafco) presented a series of unique challenges, including redeployment of an internal-turret mooring system, use of a turret-based electrical-cable jumper system, and permanent use of cable-deployed electric submersible pumps in the gravel-pack well completions. Following a detailed three-dimensional (3D) seismic program, the field was discovered by the first well in December 1990. Four subsequent appraisal wells were drilled. The discovery well and two of the appraisal wells tested oil at rates ranging from 2,000 to 10,100 B/D. Initial development plans called for the use of two conventional platforms with a pipeline to a shore-based treatment and storage terminal. Data acquired from subsequent wells were incorporated into the mapping and reserve estimates resulting in a sharp downgrade of the estimated recoverable reserves. The reduced estimate, combined with a revised pricing ...
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some ...
We have developed a liquid jet injector system that can be used for hydrated sample delivery at X-ray Free Electron Laser (XFEL) sources and 3rd generation synchrotron sources. The injector is based on the Gas Dynamic Virtual Nozzle (GDVN), which generates a liquid jet with diameter ranging from 300 nm to 20 {\\mu}m without the clogging problems associated with conventional Rayleigh jets. An improved nozzle design is presented here. A differential pumping system protects the vacuum chamber and an in-vacuum microscope allows observation of the liquid jet for diagnostics while it is being exposed to the X-ray beam. A fiber optically coupled pump laser illuminating the jet is incorporated for pump-probe experiments. First results with this injector system have been obtained at the LCLS.
Tata Electric Companies (TEC) are engaged in the generation of hydro and thermal energy. TEC, to minimise backing down of its thermal units in off peak hours and also to at least partially meet the growing deficit in the supply during peak hours is moving to install pumped storage plants (PSPs) utilising off-peak surplus energy for pumping the water from lower pond to the upper pond for subsequent utilisation for power generation during peak hours. In view of some of the infra structural facilities such as storage ponds, water conductor system, transmission lines, etc. being already available, at the existing hydro power stations owned by TEC, the pumped storage units are being proposed within the environs of existing hydro stations, i.e. a 150 MW pumped storage unit at Bhira and a 90 MW pumped storage unit at Bhivpuri. The projects are described and cost ...
...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of ยง 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...
This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of research done in the third phase of a research project that investigated components for small heat pump systems that use ammonia as a working fluid. The report includes a summary of the findings of the first two phases of the project and goes on to describe tests done with rotary vane and scroll compressors. The aims of the project are discussed and the work done is listed chronologically. The construction and the components of the test installation are described in detail. Also, the heat pump testing facilities at the University of Applied Science in Rapperswil, Switzerland, are described. The results of the measurements made for various temperature gradients are presented in detail and commented on; also, the various types of compressor tested and other heat pump compressors are compared.
The hydromechanical effect of hydroelectric stations on zooplankton is customarily regarded as a constantly acting and comparatively harmless factor, since its destruction is inevitable when water masses are passed through hydroelectric stations, but its capacity for restoration is high (i.e., destruction of the zooplankton of the forebay is compensated by its production in the after bay). It is not known how correct such an opinion is, or what is the true balance of losses and reproduction of zooplankton in the forebays and after bays of hydroelectric stations. However, hydroelectric plants of a new type, pumped-storage plants, have been constructed in recent years and others are planned for the Dnieper reservoirs. The operational principle and purpose of these plants is that they employ special vertical turbine-electric pumps that pump water at night from the reservoirs into pumped-storage ...
A centrifugal pump was developed for the efficient and reliable transfer of liquid helium in space. The pump can be used to refill cryostats on orbiting satellites which use liquid helium for refrigeration at extremely low temperatures. The pump meets the head and flow requirements of on-orbit helium transfer: a flow rate of 800 L/hr at a head of 128 J/kg. The overall pump efficiency at the design point is 0.45. The design head and flow requirements are met with zero net positive suction head, which is the condition in an orbiting helium supply Dewar. The mass transfer efficiency calculated for a space transfer operation is 0.99. Steel ball bearings are used with gas fiber-reinforced teflon retainers to provide solid lubrication. These bearings have demonstrated the longest life in liquid helium endurance tests under simulated pumping conditions. Technology developed in the project ...
Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)
Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results ...
This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.
This report is the first revision to ``Radiological Performance Assessment for the E-Area Vaults Disposal Facility, Revision 0'', which was issued in April 1994 and received conditional DOE approval in September 1994. The title of this report has been changed to conform to the current name of the facility. The revision incorporates improved groundwater modeling methodology, which includes a large data base of site specific geotechnical data, and special Analyses on disposal of cement-based wasteforms and naval wastes, issued after publication of Revision 0.
Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 communication ports.
1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be simulated. The LOBI test facility is the ...
The key to improving transmission-network security is faster response to contingencies. Now a new breed of pumped-storage plant - designed for ultra-fast response - may soon provide a tool dispatchers can use to improve network security. This type of plant can also substantially increase the effective capacity of existing transmission lines and improve the performance of thermal generating units. The Mt. Hope Waterpower Project, planned for Rockaway Township, NJ, 35 miles west of New York City, lies strategically adjacent to major load centers at the eastern end of the PJM control area and near the interconnection point with the New York Power Pool (NYPP). This location also is in an area deficient in significant generating facilities. Maximum design capacity of the project is 2000 MW, provided by six reversible pump/turbines, each with a nominal 340-MW rating. The upper reservoir, with a surface area of only 60 acres, ...
A model-based technique incorporating neural networks has been developed for process monitoring. The technique is intended for processes where the uncertainty in the reference model is larger than desired but where process measurements providing additional information about the behavior of the system are available. This data is used to reduce the uncertainty of the model. The technique has been implemented in a real-time system for monitoring operational changes of mechanical equipment for use in predictive maintenance applications. Tests on a peristaltic pump were conducted and demonstrate the advantages of the proposed technique.
The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.
The integrity of helium circulation loop flanged joints has been attracting recent attention as a design problem, in the development of high-temperature facilitiesincorporating helium loops (e.g., the VRG-50 pilot nuclear facility). Elevated temperatures and pressures, and the radiation environment, impose additional requirements on sealant materials. This applies first and foremost to rubber seals, which have found widespread favor on account of its excellent elasticity, its ability to spontaneously conform to possible changes in the clearance in the seal assembly, and the low compressive stresses developed in the flange joint assembly.
Improvements in electric submersible pumping systems have resulted in a demonstrated downhole running life of one year for low horsepower units operating in 180 C brine. The implementation of a prototype pressurized lubrication system to prevent brine intrusion and loss of lubricating oil from the motor and protector sections has been successfully tested. Second generation pressurized lubrication systems have been designed and fabricated and will be utilized in downhole production pumping tests during FY84. Pumping system lifetime is currently limited by available power cable designs that are degraded by high-temperature brine. A prototype metal-sheathed power cable has been designed and fabricated and is currently undergoing destructive and nondestructive laboratory testing. This cable design has the potential for eliminating brine intrusion into the power delivery system through the use of a hermatically sealed cable from ...
A discussion covers the LOOP project to construct an offshore pipeline system, which will connect with onshore facilities at Fourchon, La., and two onshore pipelines (26 mi 48 in. Clovelly line and 53 mi 48 in. LOCAP line) connecting Fourchon with the existing Capline system at St. James, La.; the three-phase construction schedule, the first phase due to begin in the third quarter of 1978 with, e.g., onshore pipeline and salt dome storage facility construction which will yield an expected initial throughput of 1.4 million bbl/day; the marine terminal complex, consisting of control and pumping platforms, and three 7000 hp pumps to operate the system at 45,000-100,000 bbl/hr; the offshore lines, including lines between single-point mooring units and the pumping platform, the 21 mi 48 in. pipe to Fourchon, and corrosion protection of lines by an asphalt-sand mixture or a ...
The kWh model finds the kWh outputs of each plant and reservoir capacities of hydro and pumped storage plants and minimizes the sum of fixed charges for constructing the reservoirs and generating facilities, also the fuel costs of thermal and nuclear plants. It is a linear programming problem whose constants are represented by nonlinear functions of kW running capacity of each plant. The optimal pattern of nuclear and thermal units is found by solving the linear programming problem derived for the pumped storage and hydroplants. Excluding the upper bound constraints, the number of constraint equations are few and do not increase with the number of units, although the number of variables increases. The computing time increases only in proportion to the number of groupings of generating units. Sensitivity analysis can be done easily. The detailed operational behavior of each generating unit can be taken into account.
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to ...
The Versatile Toroidal Facility (VTF) is a large laboratory plasma machine of 1 meter major radius used to carry out investigations of ionospheric plasma turbulence. Spectral analysis has been performed on plasmas produced by the electron emitters. Interest has focused on the low frequencies below the lower hybrid resonance where ion acoustic and current-convective modes have been observed. Microwaves injected from a 3,000 watt magnetron produce dramatic changes to the low frequency spectrum. First, the parametric decay instability intensifies the ion acoustic modes in the region of plasma heated by the microwaves. Second, the normally dominant current-convective modes are greatly suppressed in the heated region due to the oscillating electric field of the pump wave. When the authors probe beyond the heated region, these two pump wave effects are no longer observed, presumably because the microwaves are denied access to ...
Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in which the propulsive force was generated by rocket only, the ramjet only and ...
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of ...
Previous laboratory tests of elastomer O-rings in coal liquefaction solvents conducted at L'Garde, Inc., indicated that certain ethylenepropylenediene monomer (EPDM) compounds provided the best performance when a backup ring was used to limit swelling. Before service testing in a pump at the Wilsonville, Alabama, Advanced Coal Liquefaction Research and Development Facility, tests of six selected elastomers in the appropriate Wilsonville-produced solvent were conducted at Oak Ridge National Laboratory (ORNL). The ORNL tests measured the elastomers' changes in cross section, weight, density, and relative flexibility. Although two perfluoroelastomers showed less degradation of most properties during these tests, it was decided to proceed with service testing of two EPDM elastomers because of their much lower cost. 5 refs., 14 figs., 7 tabs.
Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)
A case study of a hypothetical offshore production fixed leg platform facility is presented. The purpose of the case study is to demonstrate the advantages offered by modern, fuel efficient large gas turbines in central power generation service for offshore production. The case study was presented using the Rolls- Royce RB211 large gas turbine with facility production of approximately 240,000 BPD of oil and 540 MMSCFD of associated gas. The gas was subjected to three stages of separation for removal of hydrocarbon liquids and water. The liquids, natural gas, and crude oil were exported from the production platform to an onshore receiving terminal. Gas compression is the service that requires the greatest amount of power for any given production facility. For this case study, gas compression represented approximately 70 per cent of the power load with the remainder represented by the liquid export pumps ...
The TESLA Test Facility (TTF) at DESY is a facility producing sub-picosecond electron pulses for the generation of VUV or soft X-ray radiation in a free electron laser (FEL). The same electron pulses would also allow the direct production of high-power coherent radiation by passing the electron beam through an undulator. Intense, coherent far-infrared (FIR) undulator radiation can be produced from electron bunches at wavelengths longer than or equal to the bunch length. The source described in this paper provides, in the wavelength range 50-300 #mu#m, a train of about 1-10 ps long radiation pulses, with about 1 mJ of optical energy per pulse radiated into the central cone. The average output power can exceed 50 W. In this conceptual design, we intend to use a conventional electromagnetic undulator with a 60 cm period length and a maximum field of 1.5 T. The FIR source will use the spent electron beam coming from the VUV FEL which allows one to ...
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency.The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It beg...
Background vibration in a CANDU plant can be used to determine the dynamic characteristics of major items of equipment, such as calandria, the fuelling machines and the primary heat transport pumps. These dynamic characteristics can then be used to verify the seismic response of the equipment which, at present, is based on theoretical models only. The feasibility and basic theory of this new approach (which uses accelerations measured at several points on a structure and does not require knowledge of the source of excitation) was established in Phase I of the study. This report is based on Phase II in which the methods of analysis developed in Phase I were improved and verified experimentally. A Fast Fourier Transform (FFT) algorithm was incorporated and an interactive curve fitting technique was developed to obtain the dynamic characteristics in the form of natural frequencies, mode shapes and damping ratios. The method is now available for ...
Thirty-nine conference papers review practical and topical aspects of hydroelectric development, from planning and design to construction, operation and refurbishment. More than half of the papers deal with small-scale hydro, reflecting the continuing strong interest in this subject throughout the world. The planning and economic evaluation of large-scale hydro schemes and pumped-storage plants, and environmental aspects of hydroelectric developments are also discussed. A special session has also been included on hydro in Latin America, where some of the world's largest schemes are planned or under construction. The papers reproduced here draw on the expertise of engineers from eighteen countries in North and South America, Europe, Asia, Australasia and Africa. All the papers were selected and indexed separately.
The analysis described demonstrates the use of benefit/cost sensitivity analysis in examining the wide range of potential damages and savings associated with converting oil-fired electric utility boilers to burn coal in Florida. This model, for the first time incorporates, in quantitative terms, environmental economic externalities into a benefit/cost ratio sensitivity analysis framework. Five different dose-response estimates of morbidity and mortality costs, property devaluation, and willing-to-pay estimates are used in combination with four acid rain dose-response models to estimate the net present worth of externality costs. The model estimates the net present worth of benefits by incorporating into a dynamic framework all relevant construction, O + M, and fuel costs of converting an electrical generation facility from using oil to coal. These benefits of fuel savings are then weighted against various combinations of ...
In many facilities, energy management is simply a matter of managing the energy required for lighting and space conditioning. In many others, however, energy management is much more complex and involves large motors and controls, industrial insulation, complex combustion monitoring, unique steam distribution problems, significant amounts of waste heat, etc. Typical facilities offering large energy management opportunities include industrial facilities, large office and commercial operations, government institutions such as schools, hospitals and prisons. Such facilities generally have specialized industrial, commercial or institutional processes that incorporate many of the concepts covered in other chapters. These processes require thorough analytical evaluations to determine the appropriate energy-saving measures. This chapter provides some examples. In this chapter the authors ...
A performance assessment of the operating Solid Waste Storage Area 6 (SWSA 6) facility for the disposal of low-level radioactive waste at the Oak Ridge National Laboratory has been prepared to provide the technical basis for demonstrating compliance with the performance objectives of DOE Order 5820.2A, Chapter 111.2 An analysis of the uncertainty incorporated into the assessment was performed which addressed the quantitative uncertainty in the data used by the models, the subjective uncertainty associated with the models used for assessing performance of the disposal facility and site, and the uncertainty in the models used for estimating dose and human exposure. The results of the uncertainty analysis were used to interpret results and to formulate conclusions about the performance assessment. This paper discusses the approach taken in analyzing the uncertainty in the performance assessment and the role of uncertainty in ...
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.
A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).
Several research programs have been conducted to evaluate the capability of natural circulation cooling of reactors following a loss of cooling accident. Both experimental and RELAP5 simulation results were obtained for these studies in a facility with vertical heated tube(s) and a unheated bypass channel. The analytical results showed that, under a certain power level, a natural circulation pattern can be developed from both initial upflow and downflow conditions, and maintained for a significant cooling period. This power level, for the discussion of this paper, is defined as the natural circulation cooling (NCC) power limit. Two import factors, namely the pump coastdown rate and the initial flow direction, are examined in this paper. In the benchmark case, as compared to the experimental results, the RELAP5 simulation program accurately predicted the transient phenomena from forced convection through flow reversal, then, into natural ...
The Geothermal Energy Association ({open_quotes}GEA{close_quotes}) will create and manage a Geothermal Heat Pump ({open_quotes}GHP{close_quotes}) Training Center to deliver GHP and HVAC courses throughout California in response to imminent demand driven by national promotion. GEA services include providing management structure, cadre, curricula, promotion and physical equipment. The Center is dedicated to infrastructure strengthening goals of the Geothermal Heat Pump Consortium, Inc. ({open_quotes}GHPC{close_quotes}), the California Energy Commission ({open_quotes}CEC{close_quotes}) and Interagency Geothermal Heat Pump Task Force, and Geothermal Energy Association ({open_quotes}GEA{close_quotes}). Second-half 1996 start-up is co-funded by GHPC, CEC, GEA and three California utilities. Initial support is to five utilities representing 70 percent of California power users. Goals include becoming market driven by year No. 3 ...
This report discusses the safety approach of the Advanced Liquid Metal reactor program, sponsored by the US Department of Energy, which relies upon passive reactor responses to off-normal condition to limit power and temperature excursions to levels that allow safety margins. Gas expansion modules (GEM) have included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Preapplication safety evaluations by the US Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned on, resulting in positive reactivity being ...
The safety approach of the Advanced Liquid Metal Reactor program, sponsored by the U.S. Department of Energy, relies upon passive reactor responses to off-normal conditions to limit power and temperature excursions to levels that allow large safety margins. Gas expansion modules (GEM) have been included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Pre-application safety evaluations by the U.S. Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned on, resulting in positive reactivity being added to ...
A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and ...
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the modified RESF system ...
This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal bridges. The test installation is described ...
This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Georgia Army National Guard (GAARNG) facility near Hinesville, Georgia, known as the National Guard Training Center (NGTC). Preliminary assessments of federal facilities are being conducted to compile the information necessary for completing preremedial activities and to provide a priority basis for completing corrective actions (where necessary) in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining previous site activities, types and quantities of hazardous substances utilized, and potential pathways by which contamination could affect public health and the environment. The scope of this assessment is limited to the facilities and past activities contained within the NGTC. Preliminary ...
... Treatment of electrical systems for pumped storage plants is not covered in the manual, although much of the information is applicable to pumped ...
Two refrains heard in the current retail wheeling debate are that a restructuring of the electric utility industry is inevitable and that its consequences are unpredictable. Notwithstanding the benefits of open competition, there are specific disadvantages of unlimited retail wheeling for some existing independent facilities and especially for hydropower plants. A capital-intensive industry, hydropower is not well-postured to compete effectively in the short-term, against new technologies and fuel sources available in the current marketplace. Hydropower is flat out non-competitive on a price basis with available new capacity. Unless hydro is afforded the same government supports offered to other renewable energy sources, only municipal plants with access to subsidized financing rates and pumped storage plants are going to be built.
A program of tests were conducted in July 1986 at the Fast Flux Test Facility (FFTF) to demonstrate that the reactor could withstand a prototypic loss of flow (LOF) without scram without sustaining fuel damage. The reactor was taken to powers up to 50%, and the main primary coolant pump motors were tripped without scramming the control rods. This paper summarizes the analyses performed to demonstrate the maintenance of redundant protection for all design events as well as potential new events introduced by the test. The analyses focused on the following consequences: (1) unexpected test behavior; (2) transient overpower event during the test; and (3) LOF event during the test.
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
We present preliminary analysis for the feasibility of the attosecond x-ray pulses at a proposed FERMI@ELETTRA free electron laser (FEL) [1]. In part 1 we restrict ourselves to minimal modifications to the proposed FEL and consider a scheme for attosecond x-ray production which can be qualified as a small add-on to a primary facility. We demonstrate that at 5-nm wavelength our scheme is capable for production of pulses with an approximate duration of 100 attoseconds at approximately 2 MW peak power and with an absolute temporal synchronization to a pump laser pulse. In part 2 we propose to use an FEL amplifier seeded by a VUV signal and to follow it by the scheme for attosecond x-ray production described in part 1.
A negative public reaction is expected to oppose plans of the British energy industry to take valuable sites for industrial and commercial projects on the ground that government demand forecasts are too high and that they downplay conservation. The United Kingdom (UK) Department of Energy points out that public inquiry always accompanies energy installations and defends the projections made by producers even though each study emphasizes the demand for its own form of energy. At issue are plans to open 150 opencast coal mines a year to compensate for diminishing oil and gas supplies, onshore drilling by oil and gas exploration teams on nearly 50,000 km/sup 2/, and sites required for onshore pipelines, synthetic natural gas facilities, pumped storage plants, and nuclear power stations and waste management. The sites under discussion raise aesthetic and ecological concerns. (DCK)
Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the cooling water. Since the liquid membrane is formed on the entire surface of the container with no drying of the outer surface, the area of cooling surface of the container can be increased, ...
Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of ...
The invention deals with a pumping plant for oil filled power cables. An air driven piston type pump is used as primary pump. A PLS (Programmable Logic control System) is used to control the oil flow to the cable(s). Improvements of the pump includes means for ensuring that the pump piston is operated also at low pressure and flow, and means for sealing off the piston rod to ensure maximum life of seals, to facilitate detection of possible leakages and to avoid contamination of the cable oil. 3 figs.
This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or ...
This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or ...
We are attempting to characterize and model the micromechanical response of highly-filled polymers. In this class of materials, the continuous plastic binder used to bond the highly-filled material dominates the observed viscoelastic response. As a result, realistic lifetime analysis of these materials will require a thorough understanding of the contribution of the plastic binder. Laboratory applications of these materials include plastic bonded explosives, propellants, a variety of specialized filled organic materials for stockpile systems, and highly filled epoxy dielectric materials for the National Ignition Facility. We have explored numerous techniques to characterize the local microstructure of plastic bonded explosives. However, insufficient funding was obtained to bring these technologies to maturity, nevertheless our present tool set is significantly better than 2 years ago. We have also made some progress in developing an appropriate micromechanical ...
This paper uses multi-pass iteration particle swarm optimization (MIPSO) to solve short term hydroelectric generation scheduling of a power system with wind turbine generators. MIPSO is a new algorithm for solving nonlinear optimal scheduling problems. A new index called iteration best (IB) is incorporated into particle swarm optimization (PSO) to improve solution quality. The concept of multi-pass dynamic programming is applied to modify PSO further and improve computation efficiency. The feasible operational regions of the hydro units and pumped storage plants over the whole scheduling time range must be determined before applying MIPSO to the problem. Wind turbine power generation then shaves the power system load curves. Next, MIPSO calculates hydroelectric generation scheduling. It begins with a coarse time stage and searching space and refines the time interval between two time stages and the search spacing pass by pass (iteration). With ...
The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In addition, there are no pipelines to be ruptured below the upper end of the reactor core with respect to the structure. Accordingly, a great amount of water can be stored in ...
A new energy concept known as centrifugal potential energy was discussed. This new energy concept is capable of increasing the pressure, temperature and enthalpy of a fluid, without having to apply work or heat transfer to the fluid. It occurs through a change in the centrifugal potential energy of the flowing fluid in a rotating frame of reference or a centrifugal force field, where work is performed internally by the centrifugal weight of the fluid. This energy concept has resulted in new energy equations, such as the Rotational Frame Bernoulli's Equation for liquids and the Rotational Frame Steady-Flow Energy Equation for gases. Applications of these equations have been incorporated into the design of centrifugal field pumps and compressors. Rather than compressing a fluid with a physical load transfer, these devices can compress a fluid via the effect of centrifugal force applied to the object. A large amount of energy is therefore ...
Beside sucker-rod-type pumps and submersible centrifugal pumps, excentric screw pumps (so-called progressing cavity pumps) belong to standard conveyors in the production of crude oil. The authors of the contribution under consideration present the further development of excentric screw pumps with respect to the reduction of fluid levels in gas wells. This further development is based on a co-operation between the operator (Rohoel Aufsuchungs AG (Gampern, Austria)), the pump supplier (NETZSCH Oilfield Products GmbH (Selb, Federal Republic of Germany)) and the Institute for Process Technologies and Machinery at the University of Erlangen-Nuernberg (Federal Republic of Germany). The authors report on first attempts with the excentric screw pump at Weizberg (Federal Republic of Germany), material investigations at the University of ...
Due to its important hydroelectric power generation facilities (about 525 plants with a total power of 13,314 MW producing about 35.3 TWh annually) Switzerland plays an important role in the interconnected European power system. Large artificial storage lakes in the Swiss Alps can generate peak power during hours of highest demand: 9700 MW are available from accumulated energy and the total power of pumped-storage facilities amounts to 1700 MW. The latter allow refilling the reservoirs at periods of low power demand and generating power at periods of peak demand. In the case of favorable conditions, the yearly average power production could be increased by 6% and the production during the winter period (October to March) by 20% by the year 2020. However, looking forward to the year 2050, the annual production is expected to decrease by 3% despite a possible extension of hydropower. This decrease is due to the enforcement of ...
A growing number of pumped storage plants installed within the US brings attention to the increasing significance of pumped storage as a source of electrical generation capacity. Because of the special benefits this technology has to offer, hydroelectric pumped storage is an option that many utilities should consider for the supply of new capacity requirements. This article surveys the development and use of pumped storage in the US, and considers the potential for the future development of this technology. Although some of the problems that have occurred on recent projects highlight the role of pumped storage as a technological proving ground, the article puts forth the view that pumped storage is maturing to play a significant role in US electricity supply.
The mixing process of feedwater and reactor water in the downcomer of an internal-pump BWR (Forsmark 1 and 2) has been numerically modelled by means of a CFD-code (FLUENT/UNS). Earlier studies with a very rough model, have shown that a new sparger design is necessary to achieve an effective HWC through improved mixing in the downcomer,. This requires detailed and accurate modelling of the flow, not only for determining the mixing quality but for avoiding negative effects like increased thermal loading of internal parts. Through three 22.5deg models containing a sparger end and half the region between spargers, the principles of a new design have been defined. Their length scales range from 7-14 mm to ca 12 m. Also the steam separator region has been incorporated in the models. A 90deg model shows that they are sufficiently accurate for the actual region. The results cannot be generalised to other regions between spargers due to geometrical ...
Radioactive waste shipping and receiving facilities presently planned for commercial and defence high level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. (author).
Radioactive waste shipping and receiving facilities presently planned for commercial and defense high-level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations, suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner.
Radioactive waste shipping and receiving facilities presently planned for commercial and defense nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. Unacceptable personnel exposure to ionizing radiation is projected to occur if current limits for radiation levels at the cask surface and current handling methods are used. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels, while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and partially automated manner. 6 refs., 12 figs.
Lichens were collected in France in the surroundings of a military nuclear facility in Burgundy, near the la Hague reprocessing plant and in an area away from any direct source of contamination. Organically bound tritium (OBT) has been analysed on 18 samples and radiocarbon on 11. It appeared that on the most contaminated spots, the OBT activity in lichens was higher than the background by a factor of 1000 and was still a factor 10-100 at a distance of 20 km from the source. Radiocarbon from la Hague could be traced by lichens. The slow metabolism of lichens makes them suitable for the follow-up of {sup 3}H and {sup 14}C, which have been incorporated by photosynthesis.
This booklet outlines the position of Manitoba's heat pump market with the objective of promoting the widespread use of geothermal heat pumps in the province. It makes reference to the size of the market, customer satisfaction with heat pumps, and opinion of key players in the industry regarding the heat pump market. The information in this booklet is drawn on market research and lessons learned in Europe and the United States. In October 2001, a group of key stakeholders in Manitoba's heat pump market attended an industry working meeting to address the issues of market barriers, market enablers and market hot buttons. Market barriers include the high cost of geothermal heat pumps, lack of consumer awareness, lack of consistent standards, and public perception that heat pumps are not reliable. Market enablers include the low and stable ...
My assignment on the SP-100 Vacuum Vessel Vacuum System Team was to perform a transient pump down analysis for the vacuum vessel that will house the SP-100 reactor during testing. Pump down time was calculated for air and helium. For all cases the proposed vacuum system will be able to pump down the vessel within the required time. The use of a larger rotary piston pump (DUO250) improves the pump down time by 35 minutes and therefore should be considered. The 6-inch duct for the roughing line is optimal, however, because all cases are well below the 24 hour time frame, the 4-inch duct is sufficient. The use of the single turbomolecular pump during pump down is sufficient. A pump down with helium in the vessel and a helium inleakage delays the time to achieve the base pressure marginally and is acceptable.
Slurry characteristics have a significant impact on centrifugal pump performance. For instance, as particle size increases or the percent solids concentration increases, pump head and efficiency decrease. Therefore, before a slurry pump is selected, it is important to define the slurry characteristics as accurately as possible. The effect of the slurry characteristics on the head and efficiency of the centrifugal pump will be emphasized (the effect on flowrate is less significant). The effect of slurry characteristics is more predominant in smaller pumps (with smaller diameter impellers) than in larger pumps. The data and relationship between the various slurry parameters have been developed from correlations and nomographs published by pump vendors from their field data and test results. The information helps to avoid specifying an ...
Many types of maintenance activities are performed on contaminated (radioactive) machines and components at the Fast Flux Test Facility (FFTF). When personnel dose levels are within permissible limits, maintenance is performed in contaminated work areas or in gloveboxes. Otherwise, maintenance is performed in the Interim Examination and Maintenance (IEM) Cell, a hot cell that is used to perform tasks that require remote operation. Maintenance is often a combination of manual and remote operation. One such operation was the cleaning of the closed loop ex-vessel machine (CLEM) core component grapple (CCG). The CLEM is used to transfer core components in and out of the reactor vessel. The CCG had not been operating properly due to buildups of metallic sodium and sodium compounds on the outside surface and internal moving parts. This paper tells how the CCG was disassembled and cleaned. Part of this task was done in a glovebox and part in the IEM Cell. Therefore, ...
This paper summarizes the progress to date by CH2M HILL and the UKAEA in development of a parametric modelling capability for estimating the costs of large nuclear decommissioning projects in the United Kingdom (UK) and Europe. The ability to successfully apply parametric cost estimating techniques will be a key factor to commercial success in the UK and European multi-billion dollar waste management, decommissioning and environmental restoration markets. The most useful parametric models will be those that incorporate individual components representing major elements of work: reactor decommissioning, fuel cycle facility decommissioning, waste management facility decommissioning and environmental restoration. Models must be sufficiently robust to estimate indirect costs and overheads, permit pricing analysis and adjustment, and accommodate the intricacies of international monetary exchange, currency fluctuations and ...
This paper summarizes the progress to date by CH2M HILL and the UKAEA in development of a parametric modelling capability for estimating the costs of large nuclear decommissioning projects in the United Kingdom (UK) and Europe. The ability to successfully apply parametric cost estimating techniques will be a key factor to commercial success in the UK and European multi-billion dollar waste management, decommissioning and environmental restoration markets. The most useful parametric models will be those that incorporate individual components representing major elements of work: reactor decommissioning, fuel cycle facility decommissioning, waste management facility decommissioning and environmental restoration. Models must be sufficiently robust to estimate indirect costs and overheads, permit pricing analysis and adjustment, and accommodate the intricacies of international monetary exchange, currency fluctuations and ...
Tanker-based floating production, storage, and offloading (FPSO) systems have been in operation since Aug. 1977, when a single-well FPSO facility was put into production by Shell Espana in the Mediterranean. The overall operational experience with this system at this field is reviewed, with special attention to the wireline workover facilities, which have proved very satisfactory. A subsequent evolutionary step, a FPSO system accommodating multiple wells, necessitated development of a multibore fluid swivel. A design program for this swivel was initiated in 1978; a prototype was built and full-scale testing finalized in 1980. A summary of the test results is presented. Simultaneously with the multibore swivel development, detailed engineering for an eight-well FPSO unit was begun. This system includes gas-lift and water injection capabilities. Provisions for through-flowline (TFL) well workover can be incorporated. The ...
This document defines the quality system requirements for the US Department of Energy, Richland Operations Office (DOE-RL), Environmental Restoration (ER) Project at the Hanford Site. The Environmental Restoration Project Quality System Requirements for the Hanford Site integrates quality assurance requirements from the DOE Orders, the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), the Hanford Facility Resource Conservation and Recovery Act of 1976 (RCRA) Permit, and applicable Federal and Washington State regulations. This document, based on ten criteria, provides user organizations with the flexibility to incorporate only those criteria and paragraphs applicable to their specific scopes of work. The requirements of this document are to be applied based on a graded approach that takes into consideration the risk inherent in, as well as the importance of, specific items, services, and ...
The authors propose an integrated indicator of pump-rod couplings that allows both the couplings and the pump operations to be appraised according to the given formula. (Formula provided). The dynamic relationships of rod operations were determined with nomographs. These relationships involve such factors as: the type and size of the sucker-rod string; the pressure load at the equalizer head and its correlation to threshold pressure at pump discharge; pump diameter; the rod weight and construction; and integral reliability indicators.
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling ...
Limestone slurry needs to move efficiently through a complex process, meaning that selecting the right pumps and valves is critical. The article discusses factors to consider in selecting pumps and values for flue gas desulfurization process in coal-fired power plants. 2 photos.
This paper describes the advent of energy pumped storage plants in France, in connection with nuclear power reactors development and gives detailed specifications of different components (pump turbines, alternators, valves ...). 5 figs., 3 tabs.
In order to reduce the length and to increase the effectiveness of processing, the proposed method for acetic processing of an electric centrifugal well pump calls for covering the pressure line during the curing and periodically starting the pump.
Using the past diffusion trends of four renewable energy technologies for irrigation water pumping in India (SPV pumps, windmill pumps and biogas/producer gas driven dual fuel engine pumps), results of an attempt to project their future dissemination levels, have been presented in this study. The likely contribution of the renewable energy options considered in the study to the projected energy demand for irrigation water pumping in India has been estimated. Estimates of the associated investment requirements taking into account the learning effect have also been presented. (author)
The purpose of the chapter is to explain briefly the various considerations that enter into determining the general layout or arrangement of typical hydroelectric powerplants, pumping plants, and pumped-storage plants. Some of the important factors that affect or determine the location, type, and layout of the plant and the selection of the major items of equipment included in the installation are outlined in this chapter. The first consideration in the design of a powerplant, pumping plant, or pumped-storage plant is that it adequately perform its function and be structurally safe. The structure is also designed to give a pleasing architectural appearance.
The advantages of using heads of around 1000 m in conjunction with underground location of the lower reservoirs for pumped storage plants are described, and the possible layouts, equipment, and construction methods are discussed.
The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)
Simple frameworks have been developed for estimating the utilization potential of: (a) solar photovoltaic (SPV) pumps; (b) windmill pumps; (c) producer gas based dual fuel engine pumps; and (d) biogas based dual fuel engine pumps for irrigation water pumping in India. The approach takes into account factors such as: solar radiation intensity, wind speed, availability of bovine dung and agri-residues, and their alternative uses, ground water requirements for irrigation and its availability, affordability, and propensity of the users to invest in renewable energy devices, etc. SPV pumps are estimated to have the maximum utilization potential in India, followed by windmill pumps. (author)
pumped storage plants; but these must be built as well since there is no correspondence with the pump and turbine operating times governed by normal network ...
A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of the surrounding ...
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 30% of the ...
The US Department of Energy (DOE) is now evaluating its facility requirements in support of its cleanup mission at Hanford. One of the early findings is that the 200-Area steam plants, constructed in 1943, will not meet future space heating and process needs. Because the 200 Area will serve as the primary area for waste treatment and long-term storage, a reliable steam supply is a critical element of Hanford operations. This Analysis and Decision Document (ADD) is a preliminary review of the steam supply options available to the DOE. The ADD contains a comprehensive evaluation of the two major acquisition options: line-term versus privatization. It addresses the life-cycle costs associated with each alternative, as well as factors such as contracting requirements and the impact of market, safety, security, and regulatory issues. Specifically, this ADD documents current and future steam requirements for the 200 Area, describes alternatives available to DOE for ...
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid ...
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The pump continues to operate successfully. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid ...
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This system is characterized by the simultaneous operation of cooling ...
The purpose of the Utility Applications Program is to provide information and assistance to interested utilities on central station energy storage systems. Compressed air and underground pumped hydroelectric energy storage are the primary technical focus. Smaller utilities are the primary targets of this program, as they may not have resources to track and utilize new energy conservation developments. The program, initiated during this year-long period, consists of a series of tasks integrating and supporting energy storage implementation. Program management and technical coordination activities monitor the wide range of research ongoing both under government support and in industry and provide a locus for dissemination of results. Recently completed DOE demonstration studies provide the central data base and the DOE CAES and UPH Technology Program activities provide another major resource. In addition a UPH preliminary feasibility study in coorination with Central ...
The energy recovery scheme at Mucking Marshes landfill site, operated by Cory Environmental Limited, has been in operation since October 1991. Using landfill gas abstracted from the site, a gas turbine generates up to 3.2 MW net electric power for export. Operation and performance of the scheme has been monitored over the period January 1995 to August 1996. Overall performance since the first use of the turbine has also been studied, and has shown reliable and profitable operation. The capital cost of the gas turbine and gas compressor plant was approximately 1.8 million. Actual gas collection wells, pipework, pumping and monitoring facilities, while essential to the scheme, are considered part of the gas control equipment needed for the landfill site. Based on a notional electricity selling price of 4p/kWh, the current annual income from exported power is 550,000. This would be substantially increased by increasing the running time and power ...
An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination factor (DF) will be measured for a ...
The adaption of the Muster-VAwS (model ordinance on the handling of water endangering substances in plants and specialized facilities) in the ordinances of the different German states, means that the legislator has laid down concrete - technical and organizational - requirements concerning the handling of water-endangering substances for all plants. The present example of the systematic stocktaking of all environmentally relevant substances in the context of the operation of the pumped storage plants of Schluchseewerk AG, Freiburg, an the application of the model operating instructions for hydropower plants shall serve to illustrate two important aspects for the implementation of this extensive ordinance. (orig.) [Deutsch] Durch Umsetzung der Muster-VAwS (Muster-Verordnung ueber Anlagen zum Umgang mit wassergefaehrdenden Stoffen und Fachbetriebe) in entsprechende Laenderverordnungen wurden durch den Gesetzgeber konkrete Anforderungen, technisch ...
Among others, one of the main activities in the Nuclear Engineering and Fluid Mechanics Department of the Engineering School in Bilbao, is the study of liquid metals behavior. And for this purpose the CFD code FLUENT is being used. Currently, the code is being applied to the use of Lead-Bismuth eutectic (LBE) as the coolant of an accelerator driven system (ADS) and also as the target for a neutron source. In this paper, ANSALDO's Energy Amplifier Demonstration Facility is simulated, paying attention only on the coolant. As it will be later explained, natural convection is a very important issue, because the philosophy for safety systems in nuclear devices tends to consider passive technologies. The purpose is to avoid electrical machines like pumps, so the core should remain coolable, even if there is a blackout. To get this natural circulation, heat transfer plays a main role, and as turbulence enhances the heat transfer, it is important to ...
Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged by German supervisory authorities with the ...
The seawater in the intake structure flows into the large pump to with draw excess heat from the turbine steam condenser. In the intake structure of a nuclear power plant, undesirable pump operating characteristics such as vortices, impeller damages and non-uniform pump-approach flow around the pump bells take place frequently due to poorly-arranged intake geometry. In this study, physical modeling test was performed to predict the hydraulic phenomenon, and proposed flow control devices.
Due to their good hydraulic characteristic semi-axial pump turbines are used in the medium head range of pumped storage plants. This paper describes model tests performed on a semiaxial pump turbine model and shows the results of these tests. The aim of the model tests was the optimization of the hydraulic water passage, the measurement of the hydraulic characteristics over the whole operating range, the investigation of the cavitation behaviour, the investigation of the hydraulic forces and torques as well as the proof of the values guaranteed to the customer.
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
The theory of reliability is used to develop statistical field data on malfunctions of units of sucker rod well pumps (UShSN). The indices of reliability of the UShSN are applied for establishment of the cause-effect links between the operating factors. Dependences of operating time on the depth of suspension of the pumps, mode of pumping out, degree of flooding of the oil, and twisting of the shafts are established for conditions of specific fields. The obtained relationships can be used in selecting and optimizing the work of the UShSN.
A novel approach to the reliability analysis of a power system with both hydro and pumped storage plants is presented in this paper. The proposed method is based on the concept of peak shaving for the hydro and pumped storage units. Different values of the stored energy of the pumped storage units are employed to demonstrate their effect on the generation reliability of a power system. The proposed scheme has been applied successfully to the reliability analysis of Taiwan power system.
A Lurgi baseline study was requested by the DOE/GRI Operating Committee of the Joint Coal Gasification Program for the purpose of updating the economics of earlier Lurgi coal gasification plant studies for the production of substitute natural gas (SNG) based on commercially advanced technologies. The current study incorporates the recent experience with large size Lurgi plants in an effort to improve capital and operating costs of earlier plant designs. The present coal gasification study is based on a mine mouth plant producing 250 billion Btu (HHV) per day of SNG using the Lurgi dry bottom coal gasification technology. A Western subbituminous coal was designated as the plant food, obtained from the Rosebud seam at Colstrip, Montana. This study presents the detailed description of an integrated facility which utilizes coal, air, and water to produce 250 billion Btu (HHV) per day of SNG. The plant consists of coal handling and preparation, ...
A new double-null, slotted divertor configuration will be installed for the DIII-D Radiative Divertor Program at General Atomics in late 1996. Four cryocondensation pumps, three new and one existing, will be part of this new divertor. The purpose of the pumps is to provide plasma density control and to limit the impurities entering the plasma core by providing pumping at each divertor strike point. The three new pumps are based on the design of the existing pump, installed in 1992 as part of the Advanced Divertor Program. The new pumps require geometry modifications to the original design. Therefore, extensive modal and dynamic analyses were performed to determine the behavior of these pumps and their helium and nitrogen feed lines during disruption events. Thermal and fluid analyses were also performed to characterize the helium two-phase ...
The influence of the main factors on device efficiency of pulsed liquid jet pump with gas-liquid piston is analysed, the theoretical equation and its time-averaged solution of pulsed liquid jet pump device efficiency are derived. The theoretical and experimental results show that the efficiency of transmission of energy and mass to use pulsed jet is greatly raised, compared with steady jet, in the same device of liquid jet pump. The calculating results of time-averaged efficiency of pulsed liquid jet pump are approximately in agreement with the experimental results in our and foreign countries
The general types of pumped-storage plants and considerations for determining their need, use, and selection are presented. A brief discussion of TVA's experience on two pumped-storage schemes is included. Pumped-storage plants have become an integral part of many hydropower systems. Most of these systems use pumped-storage plants to meet power requirements during the peak load demands. In any application, large or small, the expected load demand and supply source must be identified to select the best scheme required for the particular system.
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
This paper presents a new algorithm for the optimal long-range generation planning for a thermal system with pumped-storage plants. The algorithm is based upon the analytical production costing model developed under the assumption of Gaussian probabilistic distribution of random load fluctuations and plant outages. The optimization problem consists of the master problem to determine the annual investment, and the pumped-storage subproblem to determine the optimal pumped-storage operation. The master problem is formulated as a Hamiltonian minimization problem, and the pumped-storage subproblem is solved using the concept of peak-shaving operation on the original load curve.
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
In the development of a geothermal heat pump a water source heat pump was connected to a 1-1/2'' water line, 2200' long, buried in an endless loop 10' deep. The system is closed, circulating the same water continuously through the heat pump back to the field again. This water line 10' deep is the geothermal heat source. No matter how cold the air temperature gets on a winter day the water temperature to the heat pump will always be above 45/sup 0/F. This system has efficiently heated our house the past year using no supplemental heat.
The paper deals with the exploitation of the pumped storage plants for the control of the Slovak power system. For that purpose current utilization of pumped storage plants currently in operation was analyzed from the point of view of their part in the operation control of the Slovak power system. The aim of this analysis was to exploit knowledge gained so far for the future outlook up to the year 2010, including the evaluation of the need to construct pumped storage plant Ipel with a weekly storage cycle. (author).
The scope and contents investigate and reviewed are as follows : establishment of study plan and references survey, review of related problems and inservice test standards of safety injection pump in use nuclear power plant, review of the study results in laboratory, the theoretical investigation of temperature rise according to mini-flow rate of pump, mini-flow rate working characteristics of high and low pressure injection pumps at nuclear power plants, setup of testing equipment for measuring ampere, discharge pressure and vibration, selection and behaviors analysis of major parameters concerning pump degradation.
...Department of Environmental Control to ASARCO Incorporated. (B) Amended Administrative...Department of Environmental Control to ASARCO Incorporated. (C) Second Amended...Department of Environmental Control to ASARCO Incorporated. (ii) Additional...
This paper reports on the Burning Plasma Experiment (BPX) which when operating at a toroidal field of 8.1 tesla and a plasma current of 10.6 megamps, requires peak power of 1235 megawatts and total pulse energy of over 21 gigajoules. These requirements are twice and over four times the corresponding figures for the Tokamak Fusion Test Reactor (TFTR), respectively. The design of the BPX power system has evolved, along with the tokamak, over a period of several years and has included studies of several alternative approaches. The reapplication of the existing TFTR power and energy facilities has been basic to all approaches. Among the new sources of pulse power and energy that have been considered are: direct utility grid pulsing, new flywheel units, and lead-acid storage batteries. The toroidal field power requirements are the greatest of the BPX subsystems and, fortunately, are sufficiently free of dynamics to allow the consideration of all approaches. Additional ...
The present article describes the features of the fully-fired combined cycles and the outline of the plant. Hitachi has optimized fully-fired combined cycle systems by executing a heat recovery type combined cycle. For the fully-fired combined cycles, it is possible to raise plant efficiency through the selection of adequate gas turbine types and cycles. It is possible to apply existing boiler facilities, fuel combustion systems, and stacks. It is possible to execute civil and architectural works on existing plants in-service as well as modification works during routine inspections. The NOx increment by gas turbine unit installations can be reduced by denitration plant modifications. Examples of the fully-fired combined cycles under planning are also introduced. Furthermore, the relational technique and operational characteristics are mentioned, as for combustion characteristics under low oxygen concentration in the wind box, NOx emissions on combined cycle ...
It is generally recognized that the Remedial Investigation/Feasibility Study (RI/FS) process can be time-consuming and costly. To expedite the process, the Environmental Protection Agency, through the National Contingency Plan and Office of Solid Waste and Emergency Response (OSWER) Directives, has promoted streamlining'' the RI/FS. The concept of streamlining is directly applicable to Resource Conservation and Recovery Act (RCRA) Remedial Facility Investigation/Corrective Measure Study (RFI/CMS) as well. The US Department of Energy's (DOE's) environmental restoration process promises to be lengthy and expensive: therefore, the Office of Environmental Restoration (EM-40) believes that it is to incorporate streamlining into RI/FS and RFI/CMS efforts across the DOE complex. The Office of Program Support (EM-43) has asked Pacific Northwest Laboratory (PNL) to provide presentations and workshops on streamlining ...
Calculations have been made to determine the production of "1"8"8W from "1"8"6W in several US fission reactor systems, e.g., Fast Flux Test Facility (FFTF), the High Flux Isotope Reactor (HFIR), and the Advanced Test Reactor (ATR). Important input to these calculations are the cross-section parameters for "1"8"6W, "1"8"7W, and "1"8"8W. Only two values have been measured for "1"8"7W and none for "1"8"8W. Consequently, results from integral measurements play a crucial role in determining the "1"8"7W and "1"8"8W values. This has been studied for irradiations in the FFTF and the Oregon State Univ. (OSU) research reactor. Short irradiation of enriched "1"8"6W in both the FFTF and the OSU reactors have produced #mu#Ci/g quantities of "1"8"8W/"1"8"8Re. Measurements were made of the "1"8"8W gamma ray emission. These results were incorporated with other available data to provide more accurate "1"8"8W calculations in fission reactor systems.
Synthesis genes encoding the human #alpha#- and #beta#-globin polypeptides have been expressed from a single operon in Escherichia coli. The #alpha#- and #beta#-globin polypeptides associate into soluble tetramers, incorporate heme, and accumulate to >5% of the total cellular protein. Purified recombinant hemoglobin has the correct stoichiometry of #alpha#- and #beta#-globin chains and contains a full complement of heme. Each globin chain also contains an additional methionine as an extension to the amino terminus. The recombinant hemoglobin has a C_4 reversed-phase HPLC profile essentially identical to that of human hemoglobin A_0 and comigrates with hemoglobin A_0 on SDS/PAGE. The visible spectrum and oxygen affinity are similar to that of native human hemoglobin A_0. The authors have also expressed the #alpha#- and #beta#-globin genes separately and found that the expression of the #alpha#-globin gene alone results in a marked decrease in the accumulation of ...
A 200 ft. tall stack, consisting of a concrete chimney with an independent acid proof brick liner built in the 1950`s, serving the Separations facility at the Savannah River Site (SRS), was evaluated for the performance category 3 (PC3) level of Natural Phenomena Hazards (NPH) effects. The inelastic energy absorption capacity of the concrete chimney was considered in the evaluation of the earthquake resistance, in particular, to compute the F{sub {mu}} factor. The calculated value of F{sub {mu}} exceeded 3.0, while the seismic demand for the PC3 level, using an F{sub {mu}} value of 1.5, was found to be less than the capacity of the concrete chimney. The capacity formulation of ACI 307 was modified to incorporate the effect of an after design opening on the tension side. There are considerable uncertainties in determining the earthquake resistance of the independent brick liner. The critical liner section, located at the bottom of the breeching ...
This document defines the quality assurance program requirements for the US Department of Energy, Richland Field Office, Environmental Restoration program at the Hanford Site. This document integrates quality assurance requirements from US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order, and applicable industry standards into a single source document for the development of quality assurance programs applicable to the Environmental Restoration program items and activities. This document has been configured into three parts and fifteen criteria to provide user organizations with a workable document that best facilitates line operations. When developing individual user organization quality assurance programs, the document configuration provides each organization with the Flexibility to incorporate only those parts and criteria that are applicable to their individual scope of work as it is associated with the ...
Burnable poisons are used in nuclear reactors to produce a more level distribution of power in the reactor core and to reduce to necessity for a large control system. An ideal burnable poison would burn at the same rate as the fuel. In this study, separation of neutron-absorbing isotopes was investigated in order to eliminate isotopes that remain as absorbers at the end of fuel life, thus reducing useful fuel life. The isotopes Gd-157, Dy-164, and Er-167 were found to have desirable properties. These isotopes were separated from naturally occurring elements by means of plasma separation to evaluate feasibility and cost. It was found that pure Gd-157 could save approximately $6 million at the end of four years. However, the cost of separation, using the existing facility, made separation cost- ineffective. Using a magnet with three times the field strength is expected to reduce the cost by a factor of ten, making isotopically separated burnable poisons a favorable ...
This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Order 5400.1. This report provides supplemental information to the Hanford Site Environmental Report (PNNL-11795). The Hanford Site Environmental Report provides an update on the environmental status of the Hanford Site. The sitewide annual report summarizes the degree of compliance with applicable environmental regulations and informs the public concerning the impact of Hanford Site operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (FDH), and Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data on air emissions, liquid effluents, and hazardous substances released to the ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
During LOCA(Loss of Coolant Accident), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris could be accumulated and be clogged in the recirculation sump screen. If debris blocked the sump screen, the pressure drop increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR at 1990. Considering the important of safety, US NRC published Regulatory Guide 1.82 Rev.3 incorporating the R and D ...
During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR of USA and Sweden. Considering the important to safety, US NRC ...
As a continuation of its efforts to provide methodologies and tools to Member States to carry out comparative assessment and analyse priority environmental issues related to the development of the electric power sector, the IAEA has completed a new version of the Wien Automatic System Planning (WASP) Package WASP-IV for carrying out power generation expansion planning taking into consideration fuel availability and environmental constraints. This manual constitutes a part of this work and aims to provide users with a guide to use effectively the new version of the model WASP-IV. WASP was originally developed in 1972 by the Tennessee Valley Authority and the Oak Ridge National Laboratory in the USA to meet the IAEA needs to analyse the economic competitiveness of nuclear power in comparison to other generation expansion alternatives for supplying the future electricity requirements of a country or region. Previous versions of the model were used by Member States in many national and ...
A pump down model for a vacuum chamber with a reversibly adsorbed phase is presented. The outgassing equation which predicts the variation of coverage at the wall surface of a vacuum chamber with time is derived. Then the measured and the true outgassing rates are defined. The theoretical measured outgassing rate shows only a very weak dependence for pumping speed. This prediction is opposite to the experimental result that the measured outgassing rate depends significantly on pumping speed. It is discussed that the experimental measured outgassing rate must be described as the product of the effective pumping speed and the measured pressure in the pumped chamber, in which the measured pressure is equivalent to the equilibrium pressure of the wall surface described by the equilibrium adsorption isotherm as a function of the shifted surface coverage {theta}-{delta}{theta} by a small ...
The Electric Power Research Institute has published a report for planners, designers, owners, and operators of hydroelectric pumped-storage plants that records the operation and maintenance knowledge of 35 domestic and foreign pumped-storage projects. The report provides a comprehensive record of practices that have reduced forced outages and shortened scheduled repairs. As time passes and experienced staff retire at pumped-storage plants, many O M lessons are lost. To remedy that situation, EPRI commissioned Morrison-Knudsen Engineers Inc. to prepare a special report. The 348-page publication records the accumulated civil, geotechnical, mechanical, and electrical O M knowledge and experiences of pumped-storage plant staff. It also includes recommendations to planners and designers of future pumped-storage plants and concludes with descriptions of O M experiences reported by plant ...
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and ...
To examine the hormonal regulation of the ATP-dependent Ca{sup 2+} pump in the kidneys, the ATP-dependent Ca{sup 2+} uptake by the basolateral membrane vesicles in the renal cortex was measured using radioactive calcium ({sup 45}Ca{sup 2+}) in rats with vitamin D deficiency or rats undergoing thyroparathyroidectomy. The V{sub max} of the Ca{sup 2+} pump activity was increased not only by administering calcitriol, but also by normalizing the serum calcium level in vitamin D-deficient rats. PTH suppressed the Ca{sup 2+} pump activity in normocalcemic vitamin D-deficient rats. Thyroparathyroidectomy did not affect the Ca{sup 2+} pump activity in the kidneys of normal rats. It was concluded that the ATP-dependent Ca{sup 2+} pump activity was depressed by secondary hyperparathyroidism in vitamin D-deficient rats. (author).
To examine the hormonal regulation of the ATP-dependent Ca"2"+ pump in the kidneys, the ATP-dependent Ca"2"+ uptake by the basolateral membrane vesicles in the renal cortex was measured using radioactive calcium ("4"5Ca"2"+) in rats with vitamin D deficiency or rats undergoing thyroparathyroidectomy. The V_m_a_x of the Ca"2"+ pump activity was increased not only by administering calcitriol, but also by normalizing the serum calcium level in vitamin D-deficient rats. PTH suppressed the Ca"2"+ pump activity in normocalcemic vitamin D-deficient rats. Thyroparathyroidectomy did not affect the Ca"2"+ pump activity in the kidneys of normal rats. It was concluded that the ATP-dependent Ca"2"+ pump activity was depressed by secondary hyperparathyroidism in vitamin D-deficient rats. (author).
This paper develops optimal bidding strategies for a pumped-storage plant in a pool-based electricity market. In the competitive regime, when compared to simple hydroelectric generator, profit of the pumped-storage plant is maximized by operating it as a generator when market clearing price is high and as a pump when the price is low. Based on forecasted hourly market clearing price, a multistage looping algorithm to maximize the profit of a pumped-storage plant is developed, considering both the spinning and non-spinning reserve bids and meeting the technical operating constraints of the plant. The proposed model is adaptive for the nonlinear three-dimensional relationship between the power produced, the energy stored, and the head of the associated reservoir. Different operating cycles for a realistic pumped-storage plant are considered and simulation results are reported and ...
This paper reports on hydroelectric pumped storage which is the only proven and most efficient technology available for energy storage. It is used by utilities to provide peak and intermediate power and to optimize overall system performance. Because of increased environmental and regulatory constraints, few acceptable sites, long schedules, and huge financial commitments, large conventional pumped storage plants, are now virtually impossible to build. As an alternative, small modular pumped storage, with project sizes ranging from 25 MW to 200 MW, was created to overcome the difficulties of conventional projects. The modular approach involves standardizing the elements of a pumped storage plant by utilizing specialized siting techniques and optimizing design, equipment, and construction. Compared with conventional pumped storage, the modular design can reduce cost and expedite ...
The performance of binary geothermal power plants can be improved through the proper choice of a working fluid, and optimization of component designs and operating conditions. This paper reviews the investigations at the Idaho National Engineering Laboratory (INEL) which are examining binary cycle performance improvements: for moderate temperature (350 to 400 F) resources with emphasis on how the improvements may be integrated into design of binary cycles. These investigations are examining performance improvements resulting from the supercritical vaporization of mixed hydrocarbon working fluids and achieving countercurrent integral condensation with these fluids, as well as the modification of the turbine inlet state points to achieve supersaturated turbine vapor expansions. For resources where the brine outlet temperature is restricted, the use of turbine exhaust recuperators is examined. The baseline plant used to determine improvements in plant performance (characterized by the ...
This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation ...
This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the ...
British Nuclear Fuels plc owns and operates the near-surface Drigg disposal facility for low level radioactive waste. The long-term performance of the site is modelled by a suite of computer codes called MONDRIAN. One of the modules of MONDRIAN deals with the transport of radionuclides through the environment, and this paper reports on the current status of this module (BIOS). We derive the basic set of working equations from first principles and show clearly how the approximate nature of the final equations is arrived at. This is done by an averaging process leading to compartments, in and out of which radionuclides, solids and water can flow. The equations allow radioactive decay chains and an arbitrary number of compartments. There is also the facility to deal with changes in the rate coefficients, thereby simulating different environmental states. It is also possible to include the creation of new compartments arising as a consequence of ...
A HydroSele S seal from James Walker has provided more than two years maintenance-free service at the large Entracque pumped-storage hydroelectric scheme in Italy.
The Underground Hydroelectric Pumped Storage (UHPS) Program Plan describes in detail the planned activities and expected accomplishments in the conduct of UHPS technology development and validation envisioned in the 1976 to 1990 time frame. This document describes the program objectives, implementation strategy, and management methodology. The concept of underground hydroelectric pumped storage is fully directed to application in the electric utility industry. This technology involves using electrical energy generated by base-load plants during off-peak load periods to drive a high-head pump/turbine which pumps water from a lower reservoir to a substantially elevated (upper) reservoir corresponding to a head of 1000 m or so. The upper reservoir is at ground level and the lower reservoir is below ground. Then, during peak-load periods, water in the upper reservoir is allowed to flow to the lower ...
The computer program CNHSPM is listed which predicts heat pump seasonal energy consumption (including defrost, cyclic degradation, and supplementary heat) using steady state rating point performance and binned weather data. (LEW)
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also ...
Nuclear power plant has several safety features and each safety feature is based on the operation of pumps and valves. Therefore, it is an essential basis for the safety of nuclear power plant to keep operational readiness of pumps and valves by In-Service Test (IST). According to Ministry of Education, Science and Technology (MEST) Bulletin 2008-14, the safety functioned pumps and valves of all nuclear power plants of Korea Hydro and Nuclear Power Co. Ltd.(KHNP) have been tested to verify their performance of safety function. Each safety grade pump has own design requirement and should be tested to identify whether it could meet the requirement. Design requirements and test references of all safety grade pumps of Wolsung Nuclear Power Plant Unit 2 (Wolsung Unit 2) were examined in this study. And the results of the performance test of the pump were also ...
The article describes control and monitoring concepts in which the delegation of responsibility is becoming more decisive than ever (automation hierarchy), and which are capable of optimized, automatic control of process events in pumped storage plants. 8 refs.
Feb 24, 2000 ... NASA computer experts have been using a supercomputer to improve the NASA/ DeBakey miniature heart assist pump, leading to on-going human ...
Pumped storage plants 20 are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.That is,
Pumped storage plants are a relatively common type.They use a dam to create an upper reservoir ...Some pumped storage plants use the same water turbine and electric generator for both operating periods.
Peptic ulcer bleeding is a common disease and recurrent bleeding is an independent risk factor of mortality. Infusion with proton pump inhibitors (PPIs) prevents recurrent bleeding after successful...Full Text Available
Bolus infusion of insulin along with a meal is a standard procedure with continuous subcutaneous insulin infusion. Modern insulin pumps allow applying this bolus in four different ways: infusion of...Full Text Available
The alternative to the use of deeper wells through temperature amplification of the geothermal resource by electric heat pumps is explored. Systems in Ephrata, Washington and Chamberlain, South Dakota are explored. (MHR)
A method for recycling laser flashlamp radiation in selected wavelength ranges to decrease thermal loading of the solid state laser matrix while substantially maintaining the pumping efficiency of the flashlamp.
Homologous to bacteriorhodopsin and even more to proteorhodopsin, xanthorhodopsin is a light-driven proton pump that, in addition to retinal, contains a noncovalently bound carotenoid with a function...Full Text Available
Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for ...
BACKGROUNDOff-pump coronary artery bypass (OPCAB) surgery is associated with a hypercoagulable state in which the platelet thrombin receptor, protease-activated receptor-1...Full Text Available
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
Due to changed operational conditions and because of the increasing age of several hydro power plant components, there is an increasing risk of damages and the control of degradation mechanisms is of increasing significance. Therefore lifetime considerations for safety relevant components in pumped-storage plants become more and more important. The development of a lifetime management system, in conjunction with monitoring systems and specific surveillance for a group of pumped-storage power plants of different ages and in a wide range of power output is presented. The special focus is on the impact of fatigue strength considerations within this framework. The applied procedure will be described for typical mechanical components in pumped-storage plants exemplarily. (orig.)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
Innovative new ideas for the construction of homes are described. A thermal energy storage system fireplace and a geothermal heat pump for homes are described.
Late 1994, the Geothermal Heat Pump Consortium (GHPC) was launched as a non-profit collaborative effort between the United States Department of Energy, US electric utilities and the GeoExchange (geothermal heat pump) industry to make ''geothermal heat pumps'' a significant component of the HVAC industry and avoid 1.5 million metric tons of carbon equivalent per year. The goal was to create a self-sustainable GeoExchange market. This report offers a summary of some of the lessons learned and an overview of some of the programs major accomplishments.
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is the first accessible text/reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storge plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
All power plant engineers face the problem of peak power demands. Pumped storage plants are used to generate peak load power by pumping up water utilizing off-peak energy of hydrothermal and thermonuclear plants. This is a reference to cover hydroelectric power generation with emphasis on engineering to meet peak power demands by means of pumped storage plants, tidal power plants, and low head power generation. Text covers hydrology, mechanical and electrical equipment, accessories such as penstocks and valves, and civil engineering considerations. Contains descriptions of several existing plants. Includes 200 diagrams and 50 photographs.
A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.
... Propulsive efficiency is equivalent to the product of thrust efficiency and the hull/waterjet interaction efficiency. ... t'waterjet pump Ktorque repeated ...
Steady-state and transient behavior of the longitudinally pumped semiconductor laser is theoretically investigated by using a rate-equation model with distributed gain and photon density. Conditions necessary for bistable operation are derived. Dependencies of such major switching characteristics as turn-on and turn-off powers, delay, and rise times on laser parameters are examined. Influences of spontaneous radiation, impurities, and Auger recombination are studied. The results offer an explanation for the observed nonlinear behavior of face-pumped lasers.
Giving many examples, the contribution shows how pump operators may influence the life, efficiency and overall cost of their pumps. Further, it is shown that both the detection of unfavourable or non-optimal operating conditions and the identification of causes necessitate extensive knowledge and experience. (orig.)
This book includes the latest developments and covers pump performance, selection and operations, materials, seals and packings, effective fluid characteristics, filtration, piping systems, economics, valves, instrumentation, automatic controls, power transmission equipment, pump and pipeline heating, and more. An extensive data section contains formulas, charts, symbols, nomographs, and standard specification documents.
Pumping is one of the means for storing vast quantities of energy. This article analyses its principles and ways of implementation with emphasis on its double aspect, e.g., on the one hand, off-peak power is transferred to the periods of heaviest load and is thus valorized, even when taking into account losses due to poor efficiency of operations in the pumping and turbine modes, and on the other hand, plants have great flexibility in operation, faciliting the permanent fitting of generation to demand.
Experience and technical innovations in power plant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.
A new external-PIXE system utilizing a differential pumping technique, which can completely protect the accelerator and vacuum pumps when the exit foil breaks down, has been developed. Applications to analyses of liquid and heavily-outgassing samples were successfully achieved. Also, experiments for evaluating the efficiency of the system were performed and results will be presented. (author)
The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented
Ground water ranging in temperature from only 38/sup 0/ to 140/sup 0/F can supply a considerable amount of heat energy when couple with a geothermal or ground-water heat pump. The heat pump's method of operation is examined as well as its performance characteristics. (MHR)
The development of a gas-operated diffusion absorption heat pump for the heating of living spaces is described. By various improvement an energy efficiency of the prototypes of 1.5 was achieved. Structural alterations led to a lower overall height and lower production costs. The CFCs used in electric heat pumps were replaced by environmentally neutral ammonia. Compared with conventional gas heating systems, the CO2 output could be reduced by more than 30%. figs., tabs.
A cryocondensation pump was designed for the baffle chamber of General Atomics DIII-D tokamak and will be installed in the fall of 1992. The purpose of the pump is to study plasma density control by pumping the divertor. The pump is toroidally continuous, approximately 10 m long and located in the lower outer corner of the vacuum chamber of the machine. It consists of a 1 m{sup 2} liquid helium-cooled surface surrounded by a liquid nitrogen-cooled shield to limit the heat load on the helium-cooled surface. The liquid nitrogen-cooled surface is surrounded by a radiation/particle shield to prevent energetic particles from impacting and releasing condensed water molecules. A thermal enhancement coating was applied to the nitrogen shell to lower the maximum temperature of the shell. The coating is non-continuous to keep the toroidal electrical resistance high. The whole pump is ...
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.
The world of antibiotic drug discovery and development is driven by the necessity to overcome antibiotic resistance in common Gram-positive and Gram-negative pathogens. However, the lack of Gram-negative activity among both recently approved antibiotics and compounds in the developmental pipeline is a general trend despite the fact that the plethora of covered drug targets are well-conserved across the bacterial kingdom. Such intrinsic resistance in Gram-negative bacteria is largely attributed to the activity of multidrug resistance (MDR) efflux pumps. Moreover, these pumps also play a significant role in acquired clinical resistance. Together, these considerations make efflux pumps attractive targets for inhibition in that the resultant efflux pump inhibitor (EPI)/antibiotic combination d...
An attempt to develop a simple framework for financial evaluation of renewable energy technologies (RETs) such as photovoltaic (PV) pump, windmill pump, biogas and producer gas-driven dual fuel engine pumps for irrigation water pumping has been made. The unit cost of water and unit cost of useful energy delivered by the RETs have been estimated. The monetary benefits that accrued to the end-user have been quantified in terms of the amount of diesel or electricity saved. Financial figures of merit for the investments made in the RETs have been estimated. The effect of fuel price escalation on these measures of financial performance has also been evaluated along with the estimation of the break-even prices of fuels likely to be substituted by RETs. Results of some exemplifying calculations are presented and briefly discussed.
Abstract The purpose of this study was to compare the HL 20 roller pump (Jostra USA, Austin, TX, USA) and Rotaflow centrifugal pump (Jostra USA) on hemodynamic energy production and gaseous microemboli (GME) delivery in a simulated neonatal cardiopulmonary bypass (CPB) circuit under nonpulsatile perfusion. This study employed a simulated model of the pediatric CPB including a Jostra HL 20 heart lung machine (or a Rotaflow centrifugal pump), a Capiox BabyRX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Capiox pediatric arterial filter (Terumo Corporation), and inch tubing. The total volume of the experimental system was 700 mL (500 mL for the circuit and 200 mL for the pseudo neonatal patient). The hematocrit was maintained at 30% using human blood. At the beginning of each trial, a 5 ...
This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.
In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...
The operation of pumped-storage plants (PSP) is based on the daily load variations of power demand. It performs power generation at peak load times during the day, and pumps water up into the reservoir during the off-peak times at night. In the Taipower system in Taiwan, there are two pumped storage plants with ten units. These had a total installed capacity of 2,602 MW or a 12 percent capacity at the end of 1995. The plants were able to reduce system generation costs and improve reliability. A Pumped-Storage Plant Benefit Analysis (PSPBA) program was established using the principle of economic dispatch in 1985. This paper explains the rules of the program, the analysis results of the past 10 years, and a a cost benefit evaluation. It was found that the advantages of PSP are not only in supplying the power for peak load, but also in decreasing the total fuel cost. 5 figs., 4 refs.
Fluidic two diode pumps have been developed for moving highly toxic and for radioactive waste liquors about chemical plant. The pumps have a cylinder into which liquor is initially sucked and then expelled. For situations where no maintenance can be carried out the need has arisen for a fluidic alternator to the solenoid ejector system used on top of the pump cylinder to supply an alternating negative/positive air supply. A fluidic air alternator has been constructed by modifying a small vortex amplifier and inserting an ejector opposite to the throat of the outlet diffuser. The vortex valve ejector is described and performance characteristics are presented. Several developments of the V.V.E. for fluidic pumping and other applications are also reported. (author).
Nonevaporable getters (NEGs) have been extensively studied in the last several years for their sorption properties toward many gases. In particular, an innovative alloy as a thin film by magnetron sputtering was developed and characterized at the European Organization for Nuclear Research. It is composed of Ti-Zr-V and protected by an overlayer of palladium (Pd), according to a technology for which the authors got the licence. NEG-Pd thin films used in combination with ion getter pumps is a simple, easy way to handle pumping devices for ultrahigh and extremely high vacuum applications. To show how to apply this coating technology to the internal surface of different types of ion pumps, the authors carried out several tests on pumps of various shapes, sizes (in terms of nominal pumping speed), and types (diode, noble diode, and triode). Special care was taken during the thermal cycle ...
Under the new name of ``geothermal heat pump``, ground-source heat pumps are currently high in demand in Northern America. In sectors characterized by heating and cold air demand, their advantages can be exploited to the full. For Germany, the end-use-energy substitution potential of geothermal heat pumps has been estimated at 1310-1470 PJ annually. Whether this potential can actually be exploited depends essentially on the development of energy prices, but also on the resourcefulness of plant and heat pump manufacturers in upgrading and cheapening geothermal heat pumps. (orig./RHM) [Deutsch] Unter der neuen Bezeichnung `Geothermal Heat Pump` erlebt die erdgekoppelte Waermepumpe z.Zt. in Nordamerika einen Verbreitungsschub. In dem durch Heiz- und Kuehlbedarf charakterisierten Umfeld kann sie Ihre Vorteile voll nutzen. Fuer Deutschland kommt eine Schaetzung zu ...
Since chlordecone (Kepone, CD) interferes with cardiac Na{sup +} ion translocases, we have studied CD effects on cardiac SR calcium pump activity. SR was isolated from heart ventricles of male Sprague-Dawley rats. Cardiac SR Ca{sup 2+}-ATPase, {sup 45}Ca-uptake and cAMP as well as calmodulin (CaM) dependent protein phosphorylation were measured. Ca{sup 2+}-ATPase was differentiated into low affinity and high affinity forms by measuring the activity using 50 and 0.7 {mu}M free Ca{sup 2+} respectively. CD in vitro inhibited {sup 45}Ca-uptake by SR in a concentration dependent manner with an IC50 value of 7 {mu}M and SR {sup 45}Ca-uptake was totally inhibited at 20-30 {mu}M CD. In agreement with this, both high affinity and low affinity Ca{sup 2+}-ATPases, which are involved in Ca{sup 2+} transport across membranes, were also inhibited by CD in a concentration dependent manner with IC50 values of 0.7 and 3.2 {mu}M respectively. Both Ca{sup 2+}-ATPase and {sup ...
The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy nuclear facility located along the Savannah River near Aiken, South Carolina. During operations, which started in 1951, hazardous substances (chemicals and radionuclides) were released to the environment. The releases occurred as a result of inadvertent spills and waste disposal in unlined pits and basins which was common practice before environmental regulations existed. The hazardous substances have migrated to the vadose zone and groundwater in many areas of the SRS, resulting in 515 waste units that are required by environmental regulations, to undergo characterization and, if needed, remediation. In the initial years of the SRS environmental cleanup program (early 1990's), the focus was to use common technologies (such as pump and treat, air stripping, excavation and removal) that actively and tangibly removed contamination. Exclusive use of these ...
This report presents the results of work which included extensive modifications to HRI`s existing 3 ton per day Process Development Unit (PDU) and completion of the first PDU run. The 58-day Run 1 demonstrated scale-up of the Catalytic Two-Stage Liquefaction (CTSL Process) on Illinois No. 6 coal to produce distillate liquid products at a rate of up to 5 barrels per to of moisture-ash-free coal. The Kerr McGee Rose-SR unit from Wilsonville was redesigned and installed next to the US Filter installation to allow a comparison of the two solids removal systems. Also included was a new enclosed reactor tower, upgraded computer controls and a data acquisition system, an alternate power supply, a newly refurbished reactor, an in-line hydrotreater, interstage sampling system, coal handling unit, a new ebullating pump, load cells and improved controls and remodeled preheaters. Distillate liquid yields of 5 barrels/ton of moisture ash free coal were achieved. Coal slurry ...
The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost material for power generation using conventional and innovative ...
This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures treating such areas as the thermal interaction between cable pipes as well as the ...
Using nitrogen-13 initial measurements have been made of rumen ammonia-nitrogen pool size and turnover, and rate of incorporation of ammonia into microbial protein. It is also feasible to measure the rate of incorporation of absorbed ammonia into urea and the appearance of label in saliva.
1. β-Hydroxy-β-methyl[3-14C]glutaryl-CoA is efficiently incorporated into rubber on incubation with Hevea brasiliensis latex, and the incorporation is diminished...Full Text Available
Ruthenium-106 administered to newborn rats and swine was incorporated into the epithelium of the lower small intestine and retained there for a few weeks after gavage; the stomach and small bowel of guinea pigs incorporated "1"0"6Ru but did not retain it.
... program incorporates the proven concepts of advanced distributed learning, modeling and simulation, and electronic digital libraries (Figure 1) to ...
... In 1982 an acousto-optic spectrum analyzer incorporated ... the OPTIMP is the optically controlled optical ... switch that changes the intensity reflectance ...
The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection technique proves to be more efficient. The ...
Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar assisted ground-source heat pump (GSHP) unit and the overall system are obtained to be 2.64 and 2.38, ...
One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its ...
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the ...
This paper presents a novel organization of switch capacitor charge pump circuits based on voltage doubler structures. Each voltage doubler takes a DC input and outputs a doubled DC voltage. By cascading voltage doublers the output voltage increases up to 2 times. A two-phase voltage doubler and a multiphase voltage doubler structures are discussed and design considerations are presented. A simulator working in the Q-V realm was used for simplified circuit level simulation. In order to evaluate the power delivered by a charge pump, a resistive load is attached to the output of the charge pump and an equivalent capacitance is evaluated. To avoid the short circuit during switching, a clock pair generator is used to achieve multi-phase non-overlapping clock pairs. This paper also identifies optimum loading conditions for different configurations of the charge pumps. The proposed ...
From 1946 - 1990, i.e. from shortly after the end of World War II and the rise of the cold war until the German reunification, there had been extensive uranium mining both in Saxony and Thuringia, which formed the southern parts of the former German Democratic Republic. Mining activities started in Saxony in the Ore Mountains (German: Erzgebirge). Mining was conducted by a Soviet, since 1954 by a Soviet- German Incorporated Company named Wismut. It is estimated that about 400,000 persons may have worked in this time period with the company, most of them underground or in uranium ore processing facilities. In the early years, exposure to radiation and dust was particularly high for underground workers. After introduction of several ventilation measures and wet drilling from 1955 onwards, the levels of exposures to the various agents steadily decreased. After German reunification, it was decided by the German Federal Ministry for the Environment ...
We analyze new data from Thomas Jefferson National Accelerator Facility (JLab) for inclusive electron scattering on various targets. Computed and measured total inclusive cross sections in the range 0.3 < or approx. x < or approx. 0.95 show reasonable agreement on a logarithmic scale for all targets. However, closer inspection of the quasielastic components reveals serious discrepancies. European Muon Collaboration (EMC) ratios with conceivably smaller systematic errors fare the same. As a consequence, the new data do not enable the extraction of the magnetic form factor G{sub M}{sup n} and the structure function F{sub 2}{sup n} of the neutron, although the application of exactly the same analysis to older data had been successful. We incorporate in the above analysis older CLAS Collaboration data on F{sub 2}{sup 2H}. Removal of some scattered points from those makes it appear possible to obtain the desired neutron information. We compare ...
Since 1945, more than 1.8 x 10"2"1 Bq of artificial radionuclides have been released into the atmosphere. Approximately 2.04 x 10"1"8B, i.e. approx. 0.11%, are the result of accidents at nuclear industrial facilities. This percentage is causing increased interest among researchers. This is due to the fact that in the wake of accidental release radionuclides become distributed unevenly across the Earth's surface, and the associated exposures, fluctuating from background level to several grays, an induce both stochastic and deterministic effects in the irradiated population. A comparative analysis of the medical consequences of the twentieth century's most serious nuclear events, namely the authorized dumping of high level radioactive waste into the river Techa in 1950, the explosion of a storage tank containing long lived radioactive waste in the Southern Urals in 1957, the fire at Sellafield in 1957 and the accident at the Chernobyl nuclear power plant in 1986, has ...
The overarching goals of the 'Kootenai River Floodplain Ecosystem Operational Loss Assessment, Protection, Mitigation and Rehabilitation' Project (BPA Project No.2002-011-00) are to: (1) assess abiotic and biotic factors (i.e., geomorphologic, hydrological, aquatic and riparian/floodplain communities) in determining a definitive composition of ecological integrity, (2) develop strategies to assess and mitigate losses of ecosystem functions, and (3) produce a regional operational loss assessment framework. To produce a scientifically defensible, repeatable, and complete assessment tool, KTOI assembled a team of top scientists in the fields of hydrology, hydraulics, ornithology, entomology, statistics, and river ecology, among other expertise. This advisory team is known as the Research Design and Review Team (RDRT). The RDRT scientists drive the review, selection, and adaptive management of the research designs to evaluate the ecologic functions lost due to the ...
According to ICRP 60 and European-Directive 96/29, Naturally Occurring Radioactive Materials (NORM) and Technical Enriched Naturally Occurring Radioactive Materials (TENORM) have to take the radiation protection of the general population as well as of workers into account. The German radiation protection regulations stress that particularly. In connection with these regulations, various measurement programs have been and still are performed to investigate the relevant exposure paths. One of these programs is the determination of the intake of natural occurring radionuclides of the uranium decay series in individuals of the public, in exposed regions and houses and also at NORM workplaces by excretion analysis. Excretion analysis surveillance is one of the common tools for internal dosimetry. Sources of primordial radionuclides could be the ingestion of foodstuff and water and the incorporation of (mostly airborne) pollution on work places. The main focus in this ...
The Externally-Fired Combined Cycle (EFCC) is an attractive emerging technology for powering high efficiency combined gas and steam turbine cycles with coal or other ash bearing fuels. In the EFCC, the heat input to a gas turbine is supplied indirectly through a ceramic air heater. The air heater, along with an atmospheric coal combustor and ancillary equipment, replaces the conventional gas turbine combustor. A steam generator located downstream from the ceramic air heater and steam turbine cycle, along with an exhaust cleanup system, completes the combined cycle. A key element of the EFCC Development Program, the 25 MMBtu/h heat-input Kennebunk Test Facility (KTF), has recently begun operation. The KTF has been operating with natural gas and will begin operating with coal in early 1995. The US Department of Energy selected an EFCC repowering of the Pennsylvania Electric Company`s Warren Station for funding under the Clean Coal Technology Program Round V. The ...
Sandia is a national security laboratory operated for the U.S. department of Energy by the Sandia Corporation, a Lockheed Martin Company. Sandia designs all non-nuclear components for the nation's nuclear weapons, performs a wide variety of energy research and development projects, and works on assignments that respond to national security threats - both military and economic. They encourage and seek partnerships with appropriate U.S. industry and government groups to collaborate on emerging technologies that support their mission. Today, Sandia has two primary facilities, one in Albuquerque, New Mexico, and one in Livermore, California. They employ about 7,600 people and manage about $1.4 billion of work per year. In 1995, a decision was made to move from their in-house developed systems to commercial software. This decision was driven partly by Y2K compliance issues associated with the existing operating system and support environment. Peoplesoft was ...
Recent research work on adjustable speed pumped storage plants conducted in Japan, the USA and Europe suggests that they have many advantages over fixed-speed plants, and can contribute to power system regulation even in pump mode. This paper describes two types of static frequency converter for such pumped storage plants, especially those with greatly fluctuating heads. The design characteristics and operation of the doubly fed induction machine and the synchronous machine with DC link converter are set out and the devices compared. (UK)
The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.
Pumped storage plants (PSP) enable the storage of energy with rated capacities of order of GW at a single site. Reservoirs allow charging and discharging times of at least hours, sometimes days or even up to several weeks. Short ramp-up times permit the participation in the secondary reserve market as a standing reserve. For bulk energy storage, PSP reach the lowest, specific costs. In the EU27 countries, Norway and Switzerland, a total of 44 GW of pumped storage capacity is installed. The utilisation of PSP strongly correlates with the amount of conventional generation capacity, rather than with topographical options. (orig.)
Originally designed exclusively for peak load covering, pumped storage plants are now faced with new challenges brought about by the deregulation of the electricity market and the substantial growth of wind power capacity. Today's pumped storage plants are started more frequently and often for shorter periods of time. The grid controlling tasks have increased the importance of the role played by this type of power plant and improved sales considerably. But the operational demands have grown substantially as well. This paper discusses the ensuing adaptation of power plant operation as well as options available to power plant operators. (orig.)
The production of polarized negative ion beams by collisional pumping is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.
The production of polarized negative ion beams by ''collisional pumping'' is described. Collisional pumping utilizes repeated charge changing collisions in a thick electron-spin-polarized gas or vapor target to form a polarized fast atom beam. The polarized fast atom beam is then partially converted into a polarized negative ion beam in a vapor target. Analysis is presented for a hydrogen beam passing through either a thick polarized H atom target or a thick polarized alkali target. Large polarizations and large currents may be possible.
The lateral natural frequency and vibration response analyses of the Large Scale Breeder Reactor (LSBR) primary pump were performed as part of the total dynamic analysis effort to obtain the fabrication release. The special features of pump modeling are outlined in this paper. The analysis clearly demonstrates the method of increasing the system natural frequency by reducing the generalized mass without significantly changing the generalized stiffness of the structure. Also, a method of computing the maximum relative and absolute steady state responses and associated phase angles at given locations is provided. This type of information is very helpful in generating response versus frequency and phase angle versus frequency plots.
This report documents results of a preliminary hazard analysis (PHA) covering the existing Crane Chempump and the new salt well pumping design. Three hazardous conditions were identified for the Chempump and ten hazardous conditions were identified for the new salt well pump design. This report also presents the results of the control decision/allocation process. A backflow preventer and associated limiting condition for operation were assigned to one hazardous condition with the new design.
Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past 10 years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data were available mainly from electric utilities on heat pump performance, energy savings, and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market entry, incentive programs, and benefits.
Geothermal heat pump systems are a promising new energy technology that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to customers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school, and commercial building applications. Information was developed on the status of electric utility marketing programs, barriers to market penetration, incentive programs, and benefits.
As an application of ART2 neural networks, computer aided monitoring of pump efficiency is successfully examined for an industrial waste-liquid treatment process with measured data of valve openness and liquid flow rates. By running the neural networks in parallel, we confirm that accuracy to detect system changes is good, and the adjustment of classifier parameters is relatively easy. Investigating the resulting classes carefully, frequency of each class is correlated with pump efficiency. The relative amount of variables are also related to the classes. (author)
The use of reversible pump/turbine sets in pumped storage has created a requirement for rapid reversibility. Softstart technology, based on static frequency converters (SFC) has evolved to such an extent that it is now the best choice for serving this purpose, both from a technical and from an economic point of view. The objective of our paper is to give the owners of pumped storage plants and those persons responsible for the selection, the operation or the maintenance of the electrical equipment the necessary insight into the SFC functions, features and all other application related aspects, to facilitate their decision making process. Case studies are included.
The Michigan Electric Coordination Center (MEPCC), operated by Consumers Power and Detroit Edison Companies, has the responsibility for scheduling the Ludington pumped storage plant. Ludington has an extremely large economic effect on the Consumers Power and Detroit Edison Companies' system due to its size (over 1800 MW net demonstrated generating capability). This paper presents a dynamic programming algorithm for scheduling large pumped storage plants and shows how this method can be coordinated with the commitment of the thermal units of the system.
A descriptive model and design procedure for the DC electromagnetic flow coupler is developed based on a quasi-one-dimensional analysis previously developed for the DC electromagnetic pump. It is shown that for a particular flow coupler geometry, the total efficiency and the pressure gradients through the pump and generator depend on two parameters - the Hartmann number and the ratio of the pump flow rate to generator flow rate. Thus, for a fixed Hartmann number the efficiency depends only on the flow ratio. However, for a fixed pressure rise through the pump it is shown that the efficiency depends only on the Hartmann number. Nomographs showing the operating characteristics and critical design points are presented. Example calculations for a full-size unit, suitable for use in a liquid-metal cooled fast breeder reactor, are also discussed using the design nomographs.
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...
Within the cardiac cell, the movements of calcium ions are tightly regulated by a number of regulatory proteins including pumps, and channels. The sarcoplasmic reticulum (SR) is in large part...Full Text Available
This report presents the results of a study on Operation and Maintenance (O M) practices in hydroelectric pumped storage plants. The objective of this project, which was sponsored by EPRI, is to record the practical knowledge on the O M of a number of the domestic and foreign pumped storage plants which has been accumulated by their operating staff. Civil, geotechnical, mechanical and electrical aspects of O M of the thirty-five plants visited are discussed, and some general conclusions, as warranted by the commonality of the problems, are drawn. These conclusions may be useful to the planners and designers of future pumped storage projects. In general, due to their layout, diversity and different modes of operation, the plants have few common problems which, in most cases, are limited to the mechanical and electrical aspects of the plants' operation. The data on plants' specifications, operation and ...
Modern tubular type pumps commonly have lubricated radial bearings which require no compressed water supply and reduce the servicing requirements. Problems that may possibly result from entrained sand in the pumped fluid were solved with the development of ceramic Residur {sup trademark} bearngs in the early eighties. (orig.) [German] In zunehmendem Masse werden Rohrgehaeusepumpen mit foerdermediumgeschmierten Radiallagern ausgestattet, da dies z.B. neben dem Wegfall einer ansonsten notwendigen Druckwasserversorgung auch einen deutlichen reduzierten Wartungsaufwand nach sich zieht. Den Problemen durch eine moegliche Sandbeladung des Foerdermedium wurde bereits durch die Entwicklung der keramischen Residur {sup trademark} -Lager Anfang der 80er Jahre Rechnung getragen. (orig.)
This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee and liability are examined.
Congestive heart failure (CHF) is a leading cause of morbidity and mortality. CHF is marked by atrial and ventricular enlargement and reduced cardiac contractility, as well as an association...Full Text Available
Purpose: To eliminate the water level deviation due to the recycling flowrate, as well as enable a stable control to a reference value even upon changes in the recycling flowrate caused by the variation in the opening degree of a minimum flow valve. Constitution: Reactor recycling system comprises a feedwater pump, a flowrate control valve, a reactor water level detector, and a minimum flow line and a minimum flow valve for preventing the overheating of the feedwater pump at a low flowrate. A flowrate compensator is further disposed, in which a recycling flowrate signal is subtracted from a pump flow rate signal and the result is fedback as a compensated pump flowrate signal. This enables the control system to operate at a rapid response for suppressing the effect of the recycling flowrate as external disturbance, whereby the water level in the reactor can be controlled stably to the reference level and ...
This paper presents a new method of extracting biologic particles from a mixture of particles. The method is based on the pumping effect in a p-shaped ultrasonic actuator, which has a gap between its two vibrating metal plates. An adhesive tape is placed at a proper position in the gap. Due to the pumping effect which is induced by the sound field in the gap, the particles with smaller mass and radius in the mixture can be pumped up to reach the adhesive tape; while the ones with larger mass cannot. Therefore, the particles with smaller mass and radius can be extracted from the mixture. A theoretical model which can well explain the operation principle and experimental phenomena is developed. By the experimental results and the theoretical analyses based on the model, the validity of the m...
Many oil-insulated electric power cables are limited by heat buildup caused in part by the low thermal conductivity of the oil. Circulation of the oil is known to reduce the cable temperature, but can lead to excessive pressure buildup on long cables when using conventional pumping methods. An alternate pumping method using distributed electric fields to avoid this pressure buildup is described. Electrohydrodynamic (EHD) pumping was studied both theoretically and experimentally for possible application in underground cable cooling. Theoretical studies included both analytical and finite-element analysis of the flow patterns driven by travelling electric fields. Experimentally, flow rates in a cable-pipe model were measured under a wide variety of operating conditions. Theory and experiment are in agreement for velocities below 10 cm/s, but higher velocities could not be reached in the experiment, due to increased ...
The effects of orthovanadate on the uptake of sucrose by Ricinus cotyledons and on sucrose-coupled proton influx were measured in order to gain insight into the relationship to the plasma membrane proton pump. Vanadate had no effect on short-term sucrose uptake. In long-term experiments (> 30 min) sucrose uptake was progressively inhibited, but only at high external sucrose concentrations. Vanadate did not affect proton efflux pumping in the absence of sucrose and neither did it change the initial rate of sucrose-coupled proton influx. However, it enhanced the maximal level of sucrose-induced alkalization of the medium at all sucrose concentrations tested. This is interpreted as an inhibiting effect of vanadate on the proton pump that recycles protons during sucrose-proton cotransport. The sensitivity towards vanadate indicates that this proton pump is an ATPase. A second proton-translocating system, ...
Environmental arsenic is a world-wide health issue, making it imperative for us to understand mechanisms of metalloid uptake and detoxification. The predominant intracellular form is the highly mephitic...Full Text Available
An exergoeconomic model of a vertical ground-source heat pump residential heating system presented in this study uses exergy and cost energy mass (EXCEM) methods. The data obtained from a ground-source heat pump (GSHP) residential heating system installed at the Solar Energy Institute, Ege University, Turkey, are utilized for calculations at different reference temperature values in the range 0-25{sup o}C. The performance of the geothermal heat pump residential heating system is evaluated to indicate how exergoeconomic parameter values change with system. We also undertake a parametric study to investigate how varying reference temperatures will affect the exergoeconomic analysis of the GSHP system. A correlation between the ratio of thermodynamic loss rate to capital cost and reference state temperature is developed. (author)
The fundamental differences in the type of products sold in both Japan and the US, and some of the reasons for these differences, are outlined. Japan is the largest single country market for residential heat pumps, while the US represents the largest single country market for residential heating equipment. Quite different types and associated features of heat pumps are demanded in the USA and Japan. The term `convenience features`, used to describe the physical characteristics of the user interface device, is explained, as well as the fundamental reasons leading to the particular styles of product sold in each country: (1) product strategy and sales channels, (2) design of housing, (3) climatic factors, and (4) energy costs and distribution. It is stressed that there is no big cooling load in Japan. It is rather the comfort issue that drives the market for heat pumps
When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, ...
This ISB in conjunction with the new TSRs, will provide the required basis for interim operation or restrictions on interim operations and administrative controls for the Facility until a SAR is prepared in accordance with the new requirements. It is concluded that the risk associated with the current operational mode of the Facility, uranium closure, clean up, and transition activities required for permanent closure, are within Risk Acceptance Guidelines. The Facility is classified as a Moderate Hazard Facility because of the potential for an unmitigated fire associated with the uranium storage buildings.
All the tests have been finished up in the Waste Management and Disposal Facility which has been used for the safety tests of solidified radioactive waste on sea dumping disposal. The decommissioning of this facility was performed for use of radioisotopes. This report describes the plan on decommissioning of facility for use of radioisotopes, the contamination checking methods and measurement of radioactivity, the fore case and practice for amount of generated radioactive wastes, the operation procedures for dismantlement, the safety measures, the expenses for decommissioning and so on. (author)
TRITEX was a pumped loop with Pb-15.8Li, fabricated from steel 1.4922. In contact with the molten eutectic were also molybdenum, vanadium and armco-iron. The loop was originally designed to investigate tritium extraction using solid getter metals. Over the years the goal changed to the study of metals, corrosion products and purification of the eutectic mixture. Therefore many modifications were done. The first part of this report describes TRITEX. All parts were enclosed in thermoboxes for a homogeneous temperature. One test section was in an argon glove box and could be opened during operation. Other special equipment`s were: permeation membranes and liquid-metal-covergas-interfaces to study the transport of H{sub 2}, D{sub 2} and {sup 3}H, different purification devices, a quartz observation window to see the liquid metal surface, 4 different kinds of flow measurements, level indicators, freeze valves. The second part describes loop operation. Between 1989 and ...
{sup 14}C is a is a long-lived beta-emitting nuclide (T{sub 1/2} = 5730 years) produced naturally in the upper atmosphere as a result of reactions between neutrons and stable {sup 14}N({sup 14}N(n,p){sup 14}C). Although in a lesser extent, nuclear power plants produce {sup 14}C as well during their routine operation. Since it is converted in {sup 14}CO{sub 2} and mixed throughout the atmosphere, it is incorporated into plant tissues, via photosynthesis process, and hence in food chain. Because of the biological importance of {sup 14}C and long half-life, it is of interest to quantify the amounts released by nuclear industry. The Brazilian nuclear central named Nuclear Central Admiral Alvaro Alberto (CNAAA) has two nuclear reactors of PWR type in operation, Angra I (657 MWe) and Angra II (1350 MWe), and one under construction, Angra III (1309 MWe PWR). The aim of this study was to determine the strength of the sources and the {sup 14}C content in the environment ...
This article describes acoustic methods used in the in-service inspection of the dams and peripheral concrete structures of the Toktogul, Kurpsai, and Bratsk hydroelectric and pumped storage plants. The tests were conducted to assess the compression strength, elasticity, and tensile strength of the concretes. Comparative evaluations against drill core studies proved the acoustic methods to be sufficiently accurate in predicting aging behavior and loss of mechanical and physical integrity in the concretes.
The brochure reports on the construction and method of operation of heat pumps: - Efficiency and temperature difference - output figure - circuit processes - saving of primary energy - monovalent and bivalent plants - absorber, earth collectors - heat recovery. (HW) [Deutsch] Die Broschuere berichtet ueber den Aufbau und die Wirkungsweise von Waermepumpen: - Wirkungsgrad und Temperaturdifferenz - Leistungszahl - Kreisprozesse - Einsparung von Primaerenergie - monovalente und bivalente Anlagen - Absorber, Erdkollektoren - Waermerueckgewinnung. (HW)
Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98.
The paper sets up a simulation of a geothermal heat pump with a non-azeotropic mixture. The model is modified and verified with experimental data. The results of the simulation show that the systematic model can predict the performance within {+-}12% of the experimental data. As a result, some improvements can be provided on the basis of the simulation platform. (Author)
A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)
Previous models and evaluation techniques based on the Monte Carlo simulation for the reliability assessment of mixed hydrothermal generation systems are extended. Models for reservoirs on multiple rivers and pumped storage plants are developed. Operating and water management policies are extended to include the relative economical effects of operating alternative sources of generation. These effects and the benefits are described and discussed using an extended IEEE reliability test system. (Author).
Pumped storage plants (PSP) supply up to several GW of power and several ten GWh of capacity. Short start-up times and low start-up costs predestine PSP for the control energy market. Grid charges for PSP endanger the further integration of renewable energy and lead to higher electricity supply costs. Therefore, an amendment of legislation is urgently required. Requirements for building large PSP are met at numerous sites in the low mountain ranges of Germany. (orig.)
This paper suggests how nonlinear periodic optimal control of a pumped storage plant can be realized. The control problem consists in maximization of the plant benefits over an operational period. An optimal control law is proposed, yielding a bang-off-bang mode of operation. An algorithm for numerical solution of the problem was developed, and its effectiveness was demonstrated by simulation experiments.
Interchangeable technology from Flexicon Liquid Filling, a business division of Watson-Marlow Pumps Group, has helped family-run diagnostic reagent manufacturer, Hart Biologicals Ltd, to accommodate business growth with the recent upgrade to a tabletop bottle filling and capping machine. A peristaltic dispensing pump is crucial for succes
This report contains the results of a survey of reactor coolant pump shaft seal reliability. The survey sample is representatively large (approx. = 27% of total US commercial plant population) and includes the three industry seal suppliers (Bingham-Williamette, Byron Jackson, and Westinghouse). Operationally incurred/induced problems and seal redesign parameters are identified. Failure hypotheses in the form of fault trees have been developed to describe the failure mechanisms. Recommendations are made for seal reliability improvement.
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
This workshop on heat pipes and two-phase capillary pumping loops was organized by the French society of thermal engineers. The 11 papers presented during this workshop deal with the study of thermal performances of heat pipes and on their applications in power electronics (cooling of components), and their use in satellites, aircrafts and trains. (J.S.)
The paper describes a way to control methane that is almost self-sufficient. The Methane Buster extracts methane from longwall mines. The machinery can run virtually unattended and is fuelled by a small proportion of the methane that it extracts. The most popular model is the size of a car and weighs 3000 lbs. With pump inlet sizes varying from 6 to 24 ins. The pumps can handle up to 30,000 CFM. 3 photos.
Within the Westeuropean network of the electric current supply a continuing compensation is necessary with respect to the permanent alterations of capacity and frequency. Pumped-storage plants are of considerable significance to meet these requests. The Schluchseewerk AG, Freiburg/Breisgau, has among others five pumped-storage plants in the southern part of the Black Forest. The conception and the operation of them are described. (orig.).
The Sacramento Municipal Utility District is developing a number of demonstration projects using geothermal heat pumps. This paper discusses some of the barriers and issues that have emerged over the past two years. The most important barriers are: regulatory impediments; high first cost; and a lack of local design and installation infrastructure.
Under coaxial flash lamp pumping the laser efficiency of coumarin-4 in slightly basic ethyl alcohol solution as an active medium has reached a value of 0.14%. That is three times higher than that in the basic aqueous solution. Its tunable wavelength range of laser output has extended from 440 to 510 nm with the maximum at 460 nm.
A description is given of an automatic liquid nitrogen pumping system. Pamping of liquid nitrogen iato cooling traps up to a predetermined level is achieved by an automatically controlled compressed air system. An impontant feature of the equipment is the ability to switch automatically from an empty liquid nitrogen reservoir to a full one. This allows for a much more flexible operation than in conventional systems where the reservoir has to be replaced manually when empty. (auth)
A description of LOOP covers the single point mooring (SPM) system; the offshore pipelines connecting each SPM to the pumping platform; the offshore platform complex, a pumping platform and a control platform; the onshore pipelines; and the Clovelly Dome storage terminal.
The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space heating/cooling systems ...
The trade-off which must be established between the various functions of pumped-storage plants is examined. A compromise between supply security and economic planning can be found only by coordinated planning of pumped-storage units and thermal generation plants. A model used by Electricite de France (EDF) to ensure optimized daily planning of thermal and pumped-storage units is described. The model, called the DEMETER model, ensures the optimization of the daily planning of thermal and pumped-storage plants. The model iterates between two levels: coordination where the prices of the generated energy and the operating reserve are determined to adjust generation to load and keep a sufficient reserve; and decomposition where the schedule of each unit is optimized on the basis of the above prices and taking into account local constraints such as unavailability, and minimum shut down time. The role of EDF ...
The large number of forms and types of pump equipment in common use have different purposes and varying application requirements. This text has been prepared to bring together necessary information for those who are required to select and apply pumps in systems for all kinds of fluids and purposes. It is not a design manual. It limits the discussion of design to those factors which are necessary for an understanding of pump operation. The book contains not only descriptive information of many types of designs, but also the effect of design variation on use, economy, and reliability. Systems, an integral part of application, are discussed, so that the user of such equipment may properly select and install machines to reliably and economically satisfy his requirements. Reading of appropriate sections of the text will indicate possible problems to be avoided, and economics to be gained. The engineering design of ...
The effects of the contrast of the pump field interference pattern, that is, the effectiveness of the dynamic amplitude-phase grid, and various optical arrangements on the lasing efficiency and tuning range of a dynamic distributed-feedback dye laser are investigated. It is shown that the proper choice of prism apex angle, prism material and dye solvent in a laser in the range 400-1000 microns pumped by two beams of different intensity directed through the congruent sides of an isosceles prism in contact with the active medium solution on its third side can lead to optical losses of less than 2% from the boundaries of the prism. Measurements of polymethine dye laser efficiency and tuning range as a function of the relative intensity of the two ruby-laser pump beams reveals that as the contrast of the pump beam interference pattern decreases, the tuning range remains practically constant and the ...
Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available
The discussion of energy usage falls naturally into three parts. The first is a review of what the problem is, the second is a description of steps that can be taken to conserve energy at existing facilities, and the third is a review of the implications of energy consumption on future facilities.
In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.
This issue is the collection of the papers on progress of researches by common utilization of JAERI nuclear facilities. The 43 of the papers are indexed individually. (J.P.N.)
This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.
The United States Department of Energy (U.S. DOE) has recently implemented a series of strategic initiatives to address long-term radiological surveillance needs at former U.S. nuclear test sites in the Marshall Islands. The plan is to engage local atoll communities in developing shared responsibilities for implementing radiation protection monitoring programs for resettled and resettling populations in the northern Marshall Islands. Using the pooled resources of the U.S. DOE and local atoll governments, individual radiological surveillance programs have been developed in whole body counting and plutonium urinalysis in order to accurately assess radiation doses resulting from the ingestion and uptake of fallout radionuclides contained in locally grown foods. Permanent whole body counting facilities have been established at three separate locations in the Marshall Islands including Rongelap Atoll (Figure 1). These facilities are operated and ...
The Office of Environmental Management's (EM) Roadmap, U.S. Department of Energy--Office of Environmental Management Engineering & Technology Roadmap (Roadmap), defines the Department's intent to reduce the technical risk and uncertainty in its cleanup programs. The unique nature of many of the remaining facilities will require a strong and responsive engineering and technology program to improve worker and public safety, and reduce costs and environmental impacts while completing the cleanup program. The technical risks and uncertainties associated with cleanup program were identified through: (1) project risk assessments, (2) programmatic external technical reviews and technology readiness assessments, and (3) direct site input. In order to address these needs, the technical risks and uncertainties were compiled and divided into the program areas of: Waste Processing, Groundwater and Soil Remediation, and Deactivation and Decommissioning ...
Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the irradiated sample is ...
The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not ...
Four low activation alloy classes, two austenitic and two ferritic, have been incorporated into the MOTA-1B experiment in the FFTF reactor to provide an early assessment of the suitability of such alloys for reactor service.
It is an object of the present invention to provide an improved installation having a pressurized fluid circuit incorporating fluidic brakes for restricting fluid flow through a breach of the installation. (author).
As medical schools incorporate medical informatics into their curriculum the problems of implementation arise. Because there are no standards regarding a medical informatics curriculum, medical schools...Full Text Available
ObjectiveTo describe the development and assessment of monographs as an assignment to incorporate evidence-based medicine (EBM) and pharmacoeconomic principles into a third-year...Full Text Available
At a military base in the Southeastern US, an energy services company (ESCO) has proposed to retrofit more than 1,000 family residences with geothermal heat pumps as part of an energy savings performance contract (ESPC). Each residence is to have one heat pump with its own ground heat exchanger consisting of two or more vertical bores. A design firm hired by the ESCO sized the heat pumps to meet peak cooling loads, and sized the borefields to limit the maximum entering water temperature (EWT) to the heat pumps to 95 F (35 C). Because there is some disagreement in the geothermal heat pump industry over the peak temperature to be used for design (some designers and design manuals recommend temperatures as low as 85 F[29 C], while equipment manufacturers and others specify temperatures of 100 F[38 C] or higher) the authors were requested to examine the designs in detail to determine ...
The intensity of erbium up-conversion luminescence could be limited by a saturation effect due to increased pump power. We studied the luminescence saturation of the 550 nm emission on erbium-doped, SiO_2-TiO_2 sol-gel powders under pulsed excitation at 979 and 1532 nm. From the latter, the up-converted luminescence intensity decreased with increasing excitation power, whereas no saturation was observed at 979 nm excitation. We proposed that the saturation effect is determined by the pump power, the erbium content and the lifetime of the corresponding first excited states at different pumping schemes.
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
A brief description is given of the physico-chemical parameters characterized a hot water geothermal reservoir and of its exploitation by means of single or coupled (doublet) wells. The technical aspects of geothermal heat to the users is then discussed, beginning with corrosion of materials caused by seven main agents: oxygen, hydrogen sulphide, carbon dioxide, ammonia, hydrogen, sulphates and chlorides. A brief mention is made of scaling due to calcium carbonate, silica and calcium sulphates. The basic components of a geothermal plant for non-electric uses are then discussed: production pumps, surface pipelines, heat exchangers, heat pumps and reinjection pumps. The advantages and disadvantages of the different equipment and materials used in the geothermal sector are also presented. A list is also given of the criteria used in the energy and economic balance of a geothermal operation. (author). 24 refs, 13 figs, 2 tabs.
We study spontaneously generated entanglement (SGE) between two identical multilevel atoms in free space via vacuum-induced radiative coupling. We show that the SGE in two-atom systems may initially increase with time but eventually vanishes in the time scale determined by the excited state lifetime and radiative coupling strength between the two atoms. We demonstrate that a steady-state SGE can be established by incoherently pumping the excited states of the two-atom system. We have shown that an appropriate rate of incoherent pump can help producing optimal SGE. The multilevel systems offer us more chanel to establish entanglement. The system under consideration could be realized in a tight trap or atoms/ions doped in a solid substrate.
Currently the construction of small-scale hydroelectric and pumped storage plants is booming in the USA. The technology is attractive because of its relatively cheap construction methods and operation. Electric utilities are seeing it as a viable source of peaking power and a means of system regulation. Two schemes are described. One is a high-head/small flow river project designed to generate 3.5 MW and is about to come on line having overcome tight environmental and commercial constraints. The second is a pumped-storage project using two man-made reservoirs with an average elevation difference of 1280 ft. It is deemed to be of minimum environmental impact construction and good physical characteristics. Completion is hoped for by 1995 and the plant will deliver 1000 MW. (UK)
Repetitively Q-switched operation of an end-pumped Nd:YAG laser over the range of 200 Hz to 3 kHz using an intracavity chopper is demonstrated. Performance is shown to be comparable to that achieved with an acousto-optic Q switch under similar conditions. The advantages and limitations of the mechanical Q switch are described. Parametric variations of output coupling and pump power lead to an extended empirical description of repetitively Q-switched laser operation. The insertion loss as a function of aperture-edge penetration into the resonator is reported, and a definition of the mechanical Q-switch opening time is provided. Q-switched pulsewidths as short as 35 ns were obtained for the Nd:YAG laser, with a peak power-enhancement factor in excess of 300. PMID:20862099
Purpose: To stably control the reactor water level so as not to cause excess water feeding in a BWR type reactor. Constitution: A flow control valve is disposed to the exit of a feedwater pump for a nuclear reactor and the valve is controlled by a flow regulator to maintain the water level constant in the reactor. A signal from a water level controller is inputted to the flow regulator to thereby control the flow rate control valve. In this case, the flow regulator remains in a saturated state just after the starting of the feedwater pump, in which the pump flowrate is at 100% to result in an excess water feeding condition. In view of the above, a feedback circuit is provided to the flow regulator so that the saturated state is eliminated and the water feeding can be controlled directly from the water level controller. (Kamimura, M.).
During a regular inspection of the Boiler Auxiliaries at one of the Dutch Electricity Production Companies serious cracks were found in the cover and casings of the feed water circulation pumps in two units after 108.000 and 122.000 hours of boiler operation. Kema Laboratories carried out Failure analyses on boat samples at the cracked areas. Corrosion fatigue cracking was found on the inner side of the GS-24CrNiMo325 casing. Shop Weld repairs were carried out using a newly developed mechanized Plasma Welding Technique. The repaired feed water circulation pumps showed no problems alter several years of operation. The costs of repair were substantially lower than the costs of replacement. (orig.) 3 refs.
The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.
The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)
The low-power operation of a semiconductor buried-heterostructure Raman laser is reported. We are developing these devices for very wide-band optical communication in the terahertz frequency region. It has a structure with a GaP active layer and Al{sub {ital x}}Ga{sub 1{minus}{ital x}}P cladding layers, which are grown by the temperature-difference method under controlled vapor pressure. By making the stripe width 30--40 {mu}m, we have obtained a threshold pump power of 500 mW. A low-threshold semiconductor Raman laser can be pumped by semiconductor injection lasers. We have measured the optical loss of the waveguide and detected the contribution from scattering and leakage at heterointerfaces.
The objective of this study is to establish a construction plan for vibration analysis system of HANARO's rotating machinery. To achieve this purpose, as a first step, the references related to the vibration analysis system for the rotating machinery were investigated. In addition, to verify the possibility of condition monitoring of the pumps, vibration signals obtained from the vibration monitoring system were analyzed. The results show that using the accelerometers mounted on the bearing locations of the pumps can monitor the current status of the pump such as unbalance, misalignment, and bearing condition. Based on the results of this study, the construction plans for the vibration analysis system of HANARO have been established. The hardware of the vibration analysis system will be installed by the end of this year. It is expected that the developed vibration analysis system can be utilized for the realization ...
Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed
In this paper the possibility of using the test facility PACTEL concerning the investigations of thermal hydraulic special features of the primary coolant circuit acting under natural circulation is under consideration. It is suggested to study a stratification phenomenon of a coolant in upper plenum of a reactor and also a horizontal steam generator (HSG) hot collector temperature regime. For such investigations the facility must be modified. It is shown that this work is not large and expensive, as the facility is a lightly suitable unit for different researches. (orig.)
In this paper the possibility of using the test facility PACTEL concerning the investigations of thermal hydraulic special features of the primary coolant circuit acting under natural circulation is under consideration. It is suggested to study a stratification phenomenon of a coolant in upper plenum of a reactor and also a horizontal steam generator (HSG) hot collector temperature regime. For such investigations the facility must be modified. It is shown that this work is not large and expensive, as the facility is a lightly suitable unit for different researches. (orig.)
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
This ISB, in conjunction with the IOSR, provides the required basis for interim operation or restrictions on interim operations and administrative controls for the facility until a SAR is prepared in accordance with the new requirements or the facility is shut down. It is concluded that the risks associated with tha current and anticipated mode of the facility, uranium disposition, clean up, and transition activities required for permanent closure, are within risk guidelines.
... harassment, incidental to construction and operation of an offshore liquefied natural gas (LNG) facility. Under the Marine Mammal Protection ... ...
Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation, including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently, nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/ contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. In this paper, the context of amended Atomic Energy laws were reviewed to confirm quality assurance measures and identify additional QA activities, if ...
Contrary to the electronic excitation induced phenomena of desorption and sputtering, we observed incorporation of oxygen in a thin Fe film during its irradiation with swift heavy ions. It is observed that the adsorbed oxygen diffuses in to the Fe film. The incorporation of oxygen and its diffusion in the bulk of the film is a manifestation of extremely large electronic energy deposition by the incident ions. It is shown that the experimentally observed high diffusivity of oxygen in Fe during irradiation is due to the existence of transient melt phase of Fe.
Reactive Magnetron Sputtering is a complex process and huge efforts are made addressing the understanding of its fundamental phenomena and the simulation of the deposition process by e.g. Particle in Cell/Monte Carlo (PIC/MC). One of the most uncertain parameters in this reactive sputtering process is the incorporation coefficient of the reactive gas in the growing layer, i.e. the real-time sticking coefficient during deposition. In this work, mass spectrometry is used to deliver more insights on this complex matter. Earlier, a method was developed to determine the incorporation coefficient of the reactive gas molecules in the growing metal film, using mass spectrometry combined with thin film analysis techniques (electron probe microanalysis and x-ray photoelectron spectroscopy). This method delivers a global, realistic incorporation coefficient which can be used in models for the reactive sputtering process. In this work, ...
It was shown that the incorporation of "1"4C-linoleic acid in cerebrosides of normal and psoriatic human skin is different. In psoriatic epidermis and corium the turnover of this fatty acid is significantly elevated. It is suggested that in psoriasis the epidermal cell is not able to build up a regular carbohydrate sequences of lipids because the false carbohydrate chain activates the degradation of glycolipids and in compensating for the increased degradation raises the synthesis rate of glycolipids. (orig./MG).
Investigations of superdense compression touch on such problems as ultrahigh-frequency oscillations of matter in the generation of gravitational waves, the powerful pumping of hard coherent radiation, and the laboratory simulation of stellar interiors. This paper reviews the theory of supercompression and discusses some experiments involving multifoil collision supercompression.
Background and purpose:Diphenyleneiodonium (DPI) is often used as an NADPH oxidase inhibitor, but is increasingly being found to have unrelated side effects. We investigated its...Full Text Available
Japan has upwards of 40 pumped storage plants in operation and new river sites are becoming scarce, but peak demand is still rising. A plant under construction in Okinawa offers a solution: make use of the head between the coastal cliffs and sea level, using seawater as the medium. (author)
Pumped storage plants participate in two structurally different markets: the market for scheduled energy (also known as spot market) and the reserve market. In order to achieve the best possible plant scheduling in terms of revenues the marketing of the available capacity from pumped storage plants needs to be optimised in both markets. Moreover, due to the abilities for providing reserve, pumped storage capacities within an existing power plant portfolio can lead to synergies for the whole portfolio. The optimised combined participation of a power plant in both spot and reserve market as well as the coherent portfolio effect are considered as particular challenges in energy economic assessments, e.g. in the light of investment decisions. Based on an extension project and in cooperation with RWTH Aachen University an optimised combined participation of a power plant in both markets was simulated for the first time, thereby ...
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, which is very low compared to the consumption of electric heating (0.286 GJ per sq.m) or oil heating ...
1. In rat soleus muscle, high frequency electrical stimulation produced a rapid increase in intracellular Na+ (Na+i) content. This was considerably larger in muscles contracting without developing tension...Full Text Available
We investigated the Raman coherence characteristics of a solid hydrogen film deposited on a sapphire substrate held at 5.3 K. Using Raman coherence prepared with two single-frequency pulsed lasers, we generated the multiorder coherent Raman sidebands in solid hydrogen film. The highorder Raman sidebands were obtained under strong pumping intensities (>= 230 MW/cm{sup 2}). The generated anti-Stokes(AS)-Raman sidebands extend from the ultraviolet (292 nm for the AS5 band) to the visible (565 nm for the AS1 band) region. The multiorder Raman sideband generation is found to be due to the parametric coupling of pump and coupling lasers. The frequency conversion efficiency from pumping beams to the first AS-Raman sideband shows a maximum (14 %) at a pumping intensity of 360 MW/cm{sup 2}. From an experiment that makes the multimode probe beam beat with the prepared Raman coherence, we found that the ...
We investigated the Raman coherence characteristics of a solid hydrogen film deposited on a sapphire substrate held at 5.3 K. Using Raman coherence prepared with two single-frequency pulsed lasers, we generated the multiorder coherent Raman sidebands in solid hydrogen film. The highorder Raman sidebands were obtained under strong pumping intensities (? 230 MW/cm2). The generated anti-Stokes(AS)-Raman sidebands extend from the ultraviolet (292 nm for the AS5 band) to the visible (565 nm for the AS1 band) region. The multiorder Raman sideband generation is found to be due to the parametric coupling of pump and coupling lasers. The frequency conversion efficiency from pumping beams to the first AS-Raman sideband shows a maximum (14 %) at a pumping intensity of 360 MW/cm2. From an experiment that makes the multimode probe beam beat with the prepared Raman coherence, we found that the prepared Raman ...
Every day we are witnesses of constantly rapid increase of consumption of Electric energy in R. of Macedonia as so as in the other countries in all the world. This rapid increase of consumption of Electric energy independent of a lot of electrical units, which are applying in human life like: homes, administration and publication objects, as well as in industry. All of this conditions make us to thinking how is possible more rational consumption of electric energy in all areas in human life. One of the possible manners to reduce the consumption of electrical energy for heating and cooling is to use geothermal heat pumps. In this paper will be proposed geothermal heat pump, which is going to use the heat of earth by vertical and horizontal cupper pipe heat exchanger with data from-GHP (Geothermal Heat Pump) NORDIC, factory in Canada. Also, it will be examined all parameters and done comparison with already existing ones. It ...
The responses of the vacuolar membrane (tonoplast) proton-pumping inorganic pyrophosphatase (H+-PPase) from oat (Avena sativa L.) roots to changes in Mg2+ and...Full Text Available
Isogenic strains containing insertional disruptions of 10 Haemophilus influenzae Rd genes were investigated for their effects on the susceptibility of the organism to various classes...Full Text Available
Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the heating and cooling needs of public buildings at considerable cost reductions, ...
BackgroundCalcium homeostasis is a known target of several environmental toxicants including lead and mercury.ObjectiveOur goal was to determine...Full Text Available
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major area of activity, reported in this volume, ...
Electrical power is generated by steam turbines (steam being produced by coal, oil, gas or nuclear reactors), hydro units, gas turbines, internal combustion engines, jet engines, and pumped storage plants. Nuclear Power Plants generate only 15% of the total electrical power in the US. Nuclear Power Plants being cheaper to run are generally base loaded. The pumped-storage and gas turbine plants have ideal characteristics for peaking duty. In the pumping mode, pumped storage plants are used to provide additional system load and in the generating mode, they supply reactive power during peak load demands. Gas turbine plants have higher running costs, but are used as peaking units with a fast start capability. Fossil power plants need a minimum of 1 hour to stabilize expansion in the boiler and turbine generator. Due to a more competitive power supply market due to deregulation, most of the utilizes plan ...
1. This study analyzes the mechanisms involved in the responses to ouabain in cat cerebral and femoral arteries and characterizes the electrogenic Na+ pump present in these vessels. The latter was accomplished...Full Text Available
The dissociation of methylal is investigated using mass spectrometry, combined with a pyrolytic radical source and femtosecond pump probe experiments. Based on preliminary results two reaction paths of methylal dissociation are proposed and discussed. (author) 4 fig., 3 refs.
Object: To smoothly control automatic water supply for realizing stable operation of a nuclear reactor by providing a flow rate limiting signal selection circuit and a preferential circuit in a water supply control device for a nuclear reactor wherein the speed of a recirculation pump may be changed in two-steps. Structure: Opening angle signals for a water supply regulating valve are controlled by a nuclear reactor water level signal, a vapor flow rate signal and a supplied water flow rate signal through an adder and an adjuster in response to a predetermined water level setting signal. When the water in the reactor is maintained at a predetermined level, a selection circuit receives a water pump condition signal for selecting one of the signals from a supplied water rate limiting signal generator generating signals for indicating whether one or two water supply pumps are operated. A low value preferential circuit passes ...
Cyclophilins (Cyps), the intracellular receptors for Cyclosporine A (CsA), are responsible for peptidyl-prolyl cis-trans isomerisation and for chaperoning several membrane proteins. Those functions...Full Text Available
The F1F0 ATPase of Vibrio alginolyticus was cloned from a chromosomal lambda library. The unc operon, which contains the structural genes for the ATPase, was sequenced and shown to have a gene organization...Full Text Available
The merits of single stage absorption heat pumps coupled to simple distillation for effluent treatment are discussed. An experimental integrated absorption heat pump effluent purification system (IAHPEPS) was built and operated with water-lithium bromide as a working mixture. This unit has been used to raise the temperature and hence, the vapour pressure of the impure water contained in one vessel, to the point where pure water vapour will distil from impure effluent solution (tap water or brine) and condense in a second vessel used to collect pure water. Pure effluent production rates of between 0.5 and 4.3 kg h{sup -1} were obtained. The actual coefficient of performance (COP{sub A}) and the heat pump effectiveness varied from 1.1 to 1.4 and 0.58 to 0.72, respectively. The results from the small scale systems indicate the likely results from industrial scale units which could be operated with low quality heat such as ...
The expression of tripartite multidrug efflux pumps such as MexA-MexB-OprM in Pseudomonas aeruginosa contributes to intrinsic resistance to a wide variety of antimicrobials, including...Full Text Available
The uptake and incorporation of (/sup 3/H)adenine as a measure of total microbial (bacteria and unicellular algae) nucleic acid synthesis depends on the validity of several assumptions. A unique characteristic of the (/sup 3/H)adenine method is the ability to measure the specific radioactivity (nCi pmol/sup -1/) of the immediate precursor pool of the adenine incorporated into nucleic acids. This measurement permits correction for isotope dilution when the added radiotracer mixes with exogenous pools of structurally related compounds before uptake and with endogenous pools after transport into the cells. The immediate precursors to (/sup 3/H)adenine incorporation into cellular RNA and DNA are ATP and dATP. Since the intracellular dATP pool is in isotopic equilibrium with the ATP pool, one can determine the specific radioactivity of both precursor pools by measuring that of the intracellular ATP pool. If the specific activity ...
Laser optical pumping can be used to produce polarized alkali atom beams or polarized alkali vapor targets. Polarized alkali atom beams can be converted into polarized alkali ion beams, and polarized alkali vapor targets can be used to produce polarized H/sup -/ or /sup 3/He/sup -/ ion beams. In this paper the authors discuss how the polarized alkali atom beams and polarized alkali vapor targets are used to produce polarized ion beams with emphasis on the production of polarized negative ion beams.
This report illustrates how, thanks to the development of a new algorithm for the probabilistic evaluation in a given period (e.g. one week) of the operating costs and risk indices (reliability) of a generation system with energy-constrained units, it has been possible to significantly improve the WAT program, used for many years by ENEL for generation expansion planning studies. In particular, it describes how the annual simulation of the system operation is accomplished, so as to calculate the mean expected values of the yearly operating costs (fuel) and the risk indices, at the same time optimizing the use of hydro resources and pumped-storage plants. (author).
Excitation of the HF electric field in the local plasma resonance region (LPRR) of inhomogeneous plasma by pumping electric field or modulated electron beam results to appearance of the ponderomotive force that presses plasma out of this region. Density cavity is formed in the LPRR due to this field. Further dynamics in this region depends on the plasma properties. For plasma with hot electrons ion-acoustic pulses run away from the cavity. at the local density maximum the new peak of electric field is excited. It results to the formation of new density cavity, etc. For isothermal plasma the density jump is formed.
This letter describes the first lasing experiment of the heterostructure semiconductor Raman laser with lateral confinement of both the Stokes and pump fields. It has a GaP Raman active layer with thickness of 10 ..mu..m and Al/sub 0.1/Ga/sub 0.9/P cladding layers. The stripe of the active layer has been fabricated by a plasma etching technique. Steps should be taken to realize the semiconductor Raman laser pumped by an injection laser, applicable to wideband optical communication.
Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.
A surface may provide a useful pumping action when able to retain adsorbed gas molecules for the duration of a given experiment. To fulfil this condition at room temperature, strong binding forces, as those resulting from chemical reactions, are required. Materials able to react with gases to form stable chemical compounds are called getters. The two main families of getters (evaporable and non-evaporable, or NEG) are presented and discussed. Special emphasis is placed on the NEG strips currently used for the vacuum systems of particle accelerators, and on the newly developed NEG thin-film coatings, in view of their possible future applications.
In an electromagnetic pump of the present invention for use in circulation of coolants in an LMFBR type reactor, the outer circumference of coil conductors is covered by an insulator retaining cover, and powdery or granular insulator is filled between the coil conductors and the insulator retaining cover. Upon reaching high temperature, elongation of the coil conductors by heat expansion is absorbed by movement of the particles of the powdery insulator thereby preventing excess stresses from exerting on the coil insulator constituted with the insulator retaining cover and the powdery or granular insulator and preventing generation of crackings on the coil insulator. Thus, plant stability is improved. (N.H.).
A geothermal heat pump-assisted heating system is introduced into Changchun City and a survey is conducted to determine if the system may be popularized in this extremely cold region located in the northeastern part of China. In concrete terms, the hot water that circulates through the office building of Changchun Ground Heat Development Co., Ltd., is switched to hot water prepared by a geothermal heat pump. The test continued from December 2000 to March 2001. It is then concluded that heating by geothermal heat pumps will be fully serviceable to Changchun City. Implemented are (1) the shift from the coal fired boiler system to a geothermal heat pump system comprising 16 subterranean heat exchangers for the heating of the office building which is approximately 1000 m{sup 2} large, (2) long-term monitoring of the operating conditions, (3) measurement of subterranean heat exchanger thermal conductivity ...
The Savannah River Site (SRS) is currently developing a new facility, the Actinide Packaging and Storage Facility (APSF), to process and store legacy materials from the United States nuclear stockpile. A variety of materials, with a variety of properties, packaging and handling/storage requirements, will be processed and stored at the facility. Since these materials are hazardous and radioactive, automation will be used to minimize worker exposure. Other benefits derived from automation of the facility include increased throughput capacity and enhanced security. The diversity of materials and packaging geometries to be handled poses challenges to the automation of facility processes. In addition, the nature of the materials to be processed underscores the need for safety, reliability and serviceability. The application of automation in this facility must, ...
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural circulation, high Rayleigh numbers and low Reynolds numbers; validity ...
The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.
["1"4C]Cadaverine was applied to leaves of Lupinus polyphyllus, L. albus, L. angustifolius, L. perennis, L. mutabilis, L. pubescens, and L. hartwegii and it was preferentially incorporated into lupanine. In Lupinus arboreus sparteine was the main labelled alkaloid, in L. hispanicus it was lupanine. A pulse chase experiment with L. angustifolius and L. arboreus showed that the incorporation of cadaverine into lupanine and sparteine was transient with a maximum between 8 and 20 h. Only leaflets and chlorophyllous petioles showed active alkaloid biosynthesis, whereas no incorporation of cadaverine into lupanine was observed in roots. Using in vitro organ cultures of Lupinus polyphyllus, L. succulentus, L. subcarnosus, Cytisus scoparius and Laburnum anagyroides the inactivity of roots was confirmed. Therefore, the green aerial parts are the major site of alkaloid biosynthesis in lupins and in other legumes. (orig.).
X-ray photoelectron spectroscopy measurements indicate that the Ce{sup 3+} like fraction in {gamma}-Al{sub 2}O{sub 3} supported CeO{sub 2} can be decreased by the incorporation of La{sup 3+}. If La{sup 3+} is incorporated into the {gamma}-Al{sub 2}O{sub 3} before CeO{sub 2} is added, a higher CeO{sub 2} dispersion and a greater range of reversible reducibility of the CeO{sub 2} may also be obtained. These changes offer potential for improvement in the oxygen storage capacity provided by CeO{sub 2} in three-way catalysts. The actual effect of La{sup 3+} incorporation on the activity and durability of a Pt catalyst is assessed by a combination of temperature programmed reduction and flow reactor measurements.
This study presents a full cost approach to determine the levelized cost of energy (LCOE) of 14 electricity generation technologies. It encompasses costs incurred at all stages of the fuel cycle, including those that are traditionally omitted from economic evaluations of generation technologies. Incorporating these 'externalities' increases the likelihood of developing the most economical and sustainable power resource from a societal perspective. The following externalities are included in this analysis: damage from air pollution, energy security, transmission and distribution costs, and other environmental impacts. Incorporating externalities has a large impact on the LCOE and the relative attractiveness of electricity generation options. Results indicate that clean and efficient generation technologies are the most attractive when all options are examined using a full cost, levelized approach. (author)
Testing was performed to determine the feasibility and processing characteristics of evaporation of actual Defense Waste Processing Facility (DWPF) recycle material. Samples of the Off Gas Condensate Tank (OGCT) and Slurry Mix Evaporator Condensate Tank (SMECT) were transferred from DWPF to the Savannah River National Lab (SRNL) Shielded Cells and blended with De-Ionized (DI) water and a small amount of Slurry Mix Evaporator (SME) product. A total of 3000 mL of this feed was concentrated to approximately 90 mL during a semi-batch evaporation test of approximately 17 hours. One interruption occurred during the run when the feed tube developed a split and was replaced. Samples of the resulting condensate and concentrate were collected and analyzed. The resulting analysis of the condensate was compared to the Waste Acceptance Criteria (WAC) limits for the F/H Effluent Treatment Plant (ETP). Results from the test were compared to previous testing using simulants and ...
A limited program of field measurements was undertaken in order to define the wind characteristics of the DOE/Sandia vertical axis wind turbine test facility. Because micrometeorological conditions under which a particular wind turbine is tested may have ...
This report provides the results of a JASON review of the technical feasibility of using the Department of Energy`s (DOE`s) Fast Flux Test Facility (FFTF) to generate tritium needed for the enduring United States nuclear weapons stockpile.
A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.
The results of the two most recently completed runs at the Wilsonville Advanced Coal Liquefaction Research and Development Facility are presented. In Run 255, initial screening of operating conditions for the liquefaction of a Texas lignite was completed....
Two cases of pulmonary alveolar proteinosis, including one death, occurred in workers at a facility producing indium-tin oxide (ITO), a compound used in recent years to make flat panel displays. Both...Full Text Available
The Heat Cycle Research Facility (HCRF) is an experimental binary-cycle facility used to investigate different concepts and/or components for generating electrical power from a geothermal resource. This report briefly desc
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
This volume is a summary of the results of the final report of the Energy Engineering Analysis Program (EEAP) Study of 30 selected dining facilities at Fort Campbell, Kentucky.
Thirty-seven papers were presented at this conference in five sessions. Topics covered include regulation, control and consequences of decontamination; decontamination of components and facilities; chemical and non-chemical methods of decontamination; and TMI decontamination experience.
In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a ...
...capacity, and ownership of all planned and existing onshore pipelines, storage facilities, refineries, petrochemical...will be served by the port, including: (i) Onshore pipelines; (ii) Storage facilities; (iii)...
The Department of Energy (DOE) currently operates four thermal treatment facilities that are permitted under regulations for hazardous waste combustors. As regulations become more stringent and public stakeholders become more influential, permitting these facilities is increasingly difficult. As they become more available, continuous emission monitors (CEMs) may offer the potential to assure regulators and the public of the safe operation of treatment facilities. The Mixed Waste Focus Area (MWFA) has participated in the development and testing of a variety of CEMs that could have application to DOE facilities.
This study is an evaluation of the potential environmental impacts of contaminated groundwater from the ASARCO metals refining facility adjacent to the ...
The field of ion acceleration to higher energies has grown rapidly in the last years. Many new facilities as well as substantial upgrades of existing facilities have extended the mass and energy range of available beams. Perhaps more significant for the long-term development of the field has been the expansion in the applications of these beams, and the building of facilities dedicated to areas outside of nuclear physics. This review will cover many of these new developments. Emphasis will be placed on accelerators with final energies above 50 MeV/amu. Facilities such as superconducting cyclotrons and storage rings are adequately covered in other review papers, and so will not be covered here.
The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).
The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).
The purpose of this document is to describe the NIF Project Organization and the roles and responsibilities of the managers charged with executing the Project.
The ANDRA, the French national agency of radioactive wastes, is organizing today the information needs of tomorrow. The aim is to allow the future generations to have access to the knowledge of the existence of subsurface radioactive waste facilities and to understand the context and technologies of such facilities. The storage of this information is made on 'permanent paper', a high resistant paper with a lifetime of 600 to 1000 years. An updating of these data is made every 5 years for each waste disposal center. Another project, still in progress, concerns the memory management of deep geologic waste disposal facilities for which the time scale to be considered is of the order of millennia. (J.S.)
The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation.
Jet Propulsion Laboratory. California Institute of Technology. Pasadena, California. Energy and Water Conservation. Steve Rigdon. Facilities Energy Manager ...
... is to develop a systematic program of energy consumption reductions in compliance with the stated goals of the Army Facilities Energy Plan (AFEP ...
... projects that will result in the reduction of energy consumption in compliance with the objectives set forth in the Army Facilities Energy Plan, without ...
In order to assess whether an oil shale test facility would be of significant use to private sector oil shale developers, the US DOE has studied the past history of oil shale development and its potential for replacing petroleum supplies. A generic test facility's primary function would be to test concepts of mining, retorting, upgrading, and environmental aspects at the engineering scale. This paper summarizes the US oil shale resources, gives a technology analysis, and discusses the potential for a test facility.
Trichloroethene (TCE), a common groundwater contaminant, can be degraded under certain conditions by microorganisms that occur naturally in the subsurface. TCE can be degraded under anaerobic conditions to less chlorinated compounds and ultimately into the non-chlorinated, non-hazardous end product, ethene, via anaerobic reductive dechlorination (ARD). ARD is widely recognized as a TCE degradation mechanism, and occurs in active groundwater remediation and can occur during monitored natural attenuation (MNA). MNA relies on natural processes, such as dispersion and degradation, to reduce contaminant concentrations to acceptable levels without active human intervention other than monitoring. TCE can also be biodegraded under aerobic conditions via cometabolism, in which microbial enzymes produced for other purposes fortuitously also react with TCE. In cometabolism, TCE is oxidized directly to non-hazardous products. Cometabolism as a TCE-degrading process under aerobic conditions is less ...
An outline of Manitoba Hydro's Earth Power program was presented. Details of the heat pump market in Manitoba were provided, including details of residential and commercial sales. Total residential heat pump sales amounted to 577 units in 2004, equivalent to over $11.2 million in sales. Commercial installations amounted to approximately $12.7 million. An outline of industry players was presented. The goals of Manitoba Hydro were outlined in relation to geothermal energy and the Power Smart program. Their objectives included increasing awareness of geothermal energy, making heat pumps more accessible, and improving industry infrastructure. Other objectives included educating the public about life-cycle cost implications, residential loans and commercial incentives. To date, the residential power loan has provided financing to over 300 Manitoba home owners for installations, with electrical savings of over 1.34 Gwh and ...
In recent years, several larger geothermal heat pump plants for offices or commercial areas have been designed and built in the central region of Germany, mainly in the Rhein-Main area. Systems with borehole heat exchangers (BHE; in the USA the term Vertical Loop is commonly used) as well as with shallow geothermal doublets (groundwater wells) are operational. New solutions had to be found to adapt the technology to certain site constraints, and innovative components such as thermally-enhanced grouting material have been used. This paper reviews the early development of Ground Source Heat Pumps (GSHP) for commercial buildings, gives details on a number of recent plants and discusses problems that arose during their realisation: UEG Wetzlar, a building with chemical laboratories and one of the first examples of direct cooling from BHE; DFS Langen (German Air Traffic Control Headquarters), with 154 BHE for heating and cooling, operating without ...
Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and soil/ground) and indirect ...
In an attempt to establish a relationship between proton pumping and the photocycle intermediates of bacteriorhodopsin, we have studied the effects of pH and temperature of flash-induced proton pumping and the photointermediates O/sub 640/ and M/sub 412/. The relative quantum yield of flash-induced proton pumping is both pH and temperature dependent. It is high in the acid pH range and at low temperatures but decreases in the basic pH range and at high temperatures. The decay of M/sub 412/ is biphasic. The amplitude of the slowly decaying component (M/sup s/) was found to be pH dependent with a pK similar to that of the ..delta..pH. The pH dependence of the fast-decaying component (M/sup f/) is opposite to that of M/sup s/ and ..delta..pH. Like that of M/sup s/, the amplitude of O/sub 640/ is high in the acid pH range, but unlike the amplitude of M/sup s/, it declines very rapidly at pHs greater than 6.5; the amplitude of ...
The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009.
A decision must be made regarding whether the United State`s stockpile of neptunium should be discarded into the waste stream or kept for the production of Pu-238. Although the cost of long term storage is not inconsequential, to dispose of the material means the closing of our option to maintain control over our Pu-238 stockpile. Within the Fuels and Materials Examination Facility at Hanford there exists a remotely operated facility that can be converted for neptunium storage. This paper describes the facility and the anticipated handling requirements.
This work presents and describes the natural radioactive occurrence in oil facilities. The origins of the detected radioactivity and the reasons of its settlement are discussed. The measurements results carried out in oil facilities in the Neuquina basin (Argentine) are shown in this work. The aim is to describe the actual situation and to evaluate the magnitude of the problem. Finally, recommendations are proposed to protect the health of the workers, especially of those who carry out the cleaning of the equipment, and to guarantee an appropriate final disposal for the generated radioactive residuals. (author)
This report describes a high explosives test facility that makes efficient use of equipment and combines utility, convenience, and safety in a modest amount of space. It is a dedicated facility for exploratory development efforts that previously were conducted in a single room having very limited capabilities. Two explosives testing areas are now available and several projects are supported concurrently.
The free electron laser (FEL) FLASH at DESY in Hamburg is the first x-ray FEL ever built. Many new developments were necessary in order to exploit the unique properties of this novel light source for scientific experiments. The facility has constantly been improved and several major upgrades have been made or are currently underway. This paper reviews the main characteristics of the user facility as well as the major developments and upgrades.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
This monograph addresses a narrow aspect of cold regions engineering, namely the effects of cold weather on the traditional civil engineering disciplines of hydrology and hydraulics. Hydrologic and hydraulic considerations in the design, construction, and operation of civil works are very important. Many of the problems encountered in the design and construction of buildings, transportation systems, water supply facilities, waste treatment facilities, and hazardous waste disposal facilities, for example are closely tied to the characteristics of the site hydrology.
The presentation gives a brief insight on possibility of using the VEERA facility in studying the stratification phenomenon. The idea for such experiments is to use the facility upper plenum part to simulate the conditions in upper part of horizontal steam generator hot collector. The upper part of steam generator hot collector is one of the locations where the stratification can take part during natural circulation mode. 4 refs.
Incorporating Environmentally Conscious Materials Selection in CAD System Narito Shibaike, Matsushita Electric, Japan ...Ikeda, Matsushita Erectric H.Ishida, INAX Y.Ishikawa, Japan Techno-Economics ...Tsuchiya*, Matsushita Electric Com- ponents Y.Tsuchiya*, Society of Japanese Value
Uracil appears in DNA as a result of cytosine deamination and by incorporation from the dUTP pool. As potentially mutagenic and deleterious for cell regulation, uracil must be removed from DNA....Full Text Available
This short paper (abstract) describes the characteristics and performances of prototypes of ultra-thin lithium micro-batteries (thickness < 0.2 mm) which can be incorporated into microelectronic circuits. (J.S.)
ObjectiveTo refine the CT prediction of emphysema by comparing histology and CT for specific regions of lung. To incorporate both regional lung density measured by CT and cluster...Full Text Available
Chest compression-only (CC-only) is now incorporated in the Norwegian protocol for dispatch guided CPR (cardiopulmonary resuscitation) in cardiac arrest of presumed cardiac aetiology.We present...Full Text Available
Natural abundance 13C solid-state nuclear magnetic resonance spectroscopy was used to investigate the effect of the incorporation of cholesterol on the dynamics of dimyristoylphosphatidylcholine (DMPC)...Full Text Available
Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available
Middle segment pancreatectomy (MSP) is a new operation where the advantages of parenchymal preservation are counterbalanced by a high postoperative complication rate and unease among surgeons with adopting...Full Text Available
The article reviews the Rothschild First Interim Report on the future of the British Coal Industry and British Coal Corporation. The report incorporates work undertaken by the Joint Working Groups set up with British Coal. The article points out various errors in the report and criticizes its conclusions.
ObjectiveTo develop consistent variable names and a common database structure for the data elements in the International Spinal Cord Injury (SCI) Data Sets.Full Text Available
Activation-induced cytidine deaminase (AID) protein initiates Ig gene mutation by deaminating cytosines, converting them into uracils. Excision of AID-induced uracils by uracil-N-glycosylase...Full Text Available
User acceptance of a computer system depends on a number of factors, including broad social and professional concerns regarding the system's impact on the work environment. This observation is especially...Full Text Available
Electronic personal health records (ePHRs) can potentially maximize access and coordination of health information and improve patient/clinician collaboration, patient self-management, and health outcomes....Full Text Available
Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.
Random forest (RF) analysis of genetic data does not require specification of the mode of inheritance, and provides measures of variable importance that incorporate interaction effects. In this paper...Full Text Available
Although humans vary in their response to chemicals, comprehensive measures of susceptibility have generally not been incorporated into human risk assessment. The U.S. EPA dose-response-based risk assessments...Full Text Available
Recently, the Tri-Party Agreement (TPA) among the State of Washington Department of Ecology, U.S. Department of Energy (DOE) and the US Environmental Protection Agency (EPA) for the cleanup of the Hanford Site was renegotiated. The revised agreement specifies vitrification as the encapsulation technology for low level waste (LLW). A demonstration, testing, and evaluation program underway at Westinghouse Hanford Company to identify the best overall melter-system technology available for vitrification of Hanford Site LLW to meet the TPA milestones. Phase I is a {open_quotes}proof of principle{close_quotes} test to demonstrate that a melter system can process a simulated highly alkaline, high nitrate/nitrite content aqueous LLW feed into a glass product of consistent quality. Seven melter vendors were selected for the Phase I evaluation: joule-heated melters from GTS Duratek, Incorporated (GDI); Envitco, Incorporated (EVI); Penberthy Electomelt, ...
The formation of the nicotinamide adenine dinucleotide phosphate-dependent formate dehydrogenase in Clostridium thermoaceticum is stimulated by the presence of molybdate and selenite...Full Text Available
Changes in RNA synthesis in liver nuclei were observed at different ages and after hypophysectomy and hormone replacement in female Sprague-Dawley rats. As determined by the incorporation of [3H]UMP...Full Text Available
In response to reports that the contamination of food can occur during the on-farm primary phase of food production, we report data that describes a possible cost-effective intervention measure. The...Full Text Available
The results of clinical trials conducted in Europe and North America have been incorporated into treatment strategies for breast cancer in Japan. Despite the use of similar treatment regimens, why has...Full Text Available
The incorporation of [14C]phenylalanine and [1,6-14C]shikimic acid into tyrosine was investigated in the callus of Portulaca grandiflora, var. JR (L.). By inhibiting...Full Text Available
BackgroundThis is a preliminary report of an ongoing prospective bimodality lung cancer surveillance trial for high‐risk patients. Bimodality surveillance incorporates autofluorescence...Full Text Available
Manganous chloride and Congo red incorporated into blotting paper discs have been used to differentiate gonococci from meningococci. The new technique is simple and reliable; the materials for the test...Full Text Available
Incorporation of clinical decision support (CDS) capabilities is required to realize the greatest benefits from computerized provider order entry (CPOE) systems. Discussions at a conference on CDS in...Full Text Available
...analysis for all of the stacks except the ASARCO stacks. (i) Incorporation by reference...1985 (except for materials pertaining to ASARCO), and January 28, 1986 (except for meterials pertaining to ASARCO and Appendix A). (19) On...
...specifications of ASTM Grade 1 or Grade 2 fuel oils in ASTM Method D396-04, Standard Specification for Fuel Oils (incorporated by reference, see...ASTM Grade 4, Grade 5, or Grade 6 fuel oils in ASTM Method D396-04,...
The role of natural enemies in the regulation of populations is one of the major questions facing population ecologists. Simplification have led to two theoretical ways of incorporating the role of natural enemies in single ecological models: diffusion models and patch-type models. The predictions of the models are different because of the way variability is incorporated. Three equations are presented for diffusion models and one for patch models. Since the two types of models apply at different combinations of spatial and temporal scales, the right model(s) to choose for a particular study requires careful assessment. A continuing dialogue between experimentalists and theoreticians will lead to a better understanding of natural systems such as those that occur in biological control.
Two major developments have given impetus to wider adoption of variable-speed turbine/generators in hydroelectric plants, both essentially environmental: (1) the need for stream-bed stability below river dams, and (2) the need to minimize fish damage. Also, the need to stabilize pumped-storage and generating efficiencies to match extreme changes in head levels has been a driving force. Variable-speed operation in hydro applications is relatively new to North America. In other parts of the world, it has been used in pumped-storage plants since 1971. In the US, and increasing potential exists for variable-speed hydro, considering the 30 pumped-storage plants already in operation and several river plants struggling with high head fluctuations--including four at stations operated by the Bonneville Power Administration. Several modifications to hydro-plant hardware and operating procedures are actively being considered at ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
Most pumped-storage plants have the capability to operate as synchronous condensers. As such, they can be brought on line very quickly to support system load requirements. However, one of the effects of making a rapid transition from synchronous condenser operation to turbine/governor operation is an initial reverse power flow into the machine. This reverse power flow can be very undesirable at a time when the system is calling for load support. On weak or isolated systems, this reverse power flow can lead to objectionable voltage and frequency dips in the system. With the proper utilization of a static frequency converter (SFC) and its associated controls and auxiliary switchgear systems, the reverse power flow resulting from a transition from synchronous condenser operation can be eliminated. This paper will describe the method by which an SFC system can be used to make this rapid load response in pumped-storage plants without incurring a ...
The K0.5 for intracellular sodium of the two forms of (Na ,K )-ATPase which exist in rat adipocytes has been determined by incubating the cells in the absence of potassium in buffers of varying sodium concentration; these conditions shut off the Na pump and allow sodium to equilibrate into the cell. The activity of (Na ,K )-ATPase was then monitored with YWRb /K pumping which was initiated by adding isotope and KCl to 5 mM, followed by a 3-min uptake period. Atomic absorption and SSNa tracer equilibration were used to determine the actual intracellular (Na ) under the different conditions. The K0.5 values thus obtained were 17 mM for alpha and 52 mM for alpha(+). Insulin treatment of rat adipocytes had no effect on the intracellular (Na+) nor on the Vmax of YWRb /K pumping, but did produce a shift in the sodium ion K0.5 values to 14 mM for alpha and 33 mM for alpha(+). This change in affinity can explain the selective ...
Non-evaporable thin film getters of various compositions have been produced by sputtering. Among about 20 materials which have been studied, the lowest activation temperature (about 180 degree C) has been displayed by a Ti-Zr-V coating obtained from a cathode made of intertwisted elemental wires. In order to optimize the vacuum properties of this film various production parameters, including the substrate temperature during coating, have been varied. The films have been characterized by pumping speed measurement, secondary electron microscopy, and X-ray diffraction. It has been found that the substrate coating temperature affects significantly the activation temperature, the pumping speed and the gas surface capacity. The highest pumping speed values, obtained for substrate coating temperatures of 250 degree C and 300 degree C, are clearly correlated with the increased surface roughness and porosity of the Ti-Zr-V film.
Environmental targets and saving energy have become ones of the world main concerns over the last years and it will increase and become more important in a near future. The world population growth rate is the major factor contributing for the increase in global pollution and energy and water consumption. In 2005, the world population was approximately 6.5 billion and this number is expected to reach 9 billion by 2050 [United Nations, 2008. (www.un.org), accessed on July]. Water supply systems use energy for pumping water, so new strategies must be developed and implemented in order to reduce this consumption. In addition, if there is excess of hydraulic energy in a water system, some type of water power generation can be implemented. This paper presents an optimization model that determines the best hourly operation for 1 day, according to the electricity tariff, for a pumped storage system with water consumption and inlet discharge. Wind ...
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with heat pump systems to obtain substantial reductions in energy consumption, heating bills and urban air ...
The Geothermal Heat Pump (GHP) concept was originally developed in the 1940`s. Recently, because of increasing energy costs, utility interest, and the development of simple and durable ground source heat exchangers, GHP`s have gained international attention as a proven means of energy conservation and electrical peak power demand reduction. GHP systems require installation of a buried heat exchanger to utilize the nearly constant ground temperature making them more efficient than conventional air source heat pumps. However, the high installation cost for both residential and commercial applications is a major obstacle to their market penetration. Sandia National Laboratories (SNL) through its sponsors, the Department of Energy (DOE), and the Department of Defense (DOD), has embarked on a research program to find ways to reduce GHP installation costs and improve performance, thereby increasing their market penetration. The major elements of the ...
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the cooling oil. The second major area of activity, reported in volume 2, ...
The integrity of the cables located in the target room is very important in the Fire PSA, because the CDF and CCDP are changed according to the results of a cable integrity that depends on the surrounding gas temperature. The conservative assumptions used in the Fire PSA typically specify that all of the equipment and cables of a room would fail when a fire happens in the room. But the realistic assessment of a fire risk by using a fire simulation tool has become necessary in the Fire PSA as described in the ANS Fire PRA Standard. This paper evaluates the cable integrity of eight pump rooms in the nuclear power plant by using the CFAST zone fire model. The upper layer gas temperature of each room is estimated, and an analysis based on the results of model simulations is used to judge the cable integrity. According to the analysis results, the integrity of the cable located in the upper layer in the pump rooms is maintained without any thermal ...
This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.
Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America
This report estimates the economic and financial effects and the benefits of compliance with the proposed effluent limitations guidelines and standards for the Centralized Waste Treatment (CWT) industry. The Environmental Protection Agency (EPA) has measured these impacts in terms of changes in the profitability of waste treatment operations at CWT facilities, changes in market prices to CWT services, and changes in the quantities of waste management at CWT facilities in six geographic regions. EPA has also examined the impacts on companies owning CWT facilities (including impacts on small entities), on communities in which CWT facilities are located, and on environmental justice. EPA examined the benefits to society of the CWT effluent limitations guidelines and standards by examining cancer and non-cancer health effects of the regulation, recreational benefits, and cost savings to publicly owned ...
The Decree specifies basic quality assurance requirements applicable to machines, their parts and materials, civil engineering structures, means for automated control of technological processes including hardware and software, and electricity supply systems related to nuclear safety of nuclear facilities, and stipulates binding procedures for the implementation of technical and organizational provisions associated with the quality of selected equipment to ensure nuclear safety of nuclear facilities. Safety classes are defined for selected equipment. Requirements laid on safety assurance documentation are specified, and requirements placed on safety assurance programmes, their preparation, finalization and approval are defined. Quality assurance requirements are also specified with respect to the designing, manufacture, construction, operation, repair, modification and decommissioning of nuclear facilities. The Decree ...