WorldWideScience
1

Status of safety at Areva group facilities. 2007 annual report; Areva, etat de surete des installations nucleaires. Rapport annuel 2007  

Energy Technology Data Exchange (ETDEWEB)

This report describes the status of nuclear safety and radiation protection in the facilities of the AREVA group and gives information on radiation protection in the service operations, as observed through the inspection programs and analyses carried out by the General Inspectorate in 2007. Having been submitted to the group's Supervisory Board, this report is sent to the bodies representing the personnel. Content: 1 - A look back at 2007 by the AREVA General Inspector: Visible progress in 2007, Implementation of the Nuclear Safety Charter, Notable events; 2 - Status of nuclear safety and radiation protection in the nuclear facilities and service operations: Personnel radiation protection, Event tracking, Service operations, Criticality control, Radioactive waste and effluent management; 3 - Performance improvement actions; 4 - Description of the ...

2007-07-01

2

Analysis of tritium mission FMEF/FAA fuel handling accidents  

Energy Technology Data Exchange (ETDEWEB)

The Fuels Material Examination Facility/Fuel Assembly Area is proposed to be used for fabrication of mixed oxide fuel to support the Fast Flux Test Facility (FFTF) tritium/medical isotope mission. The plutonium isotope mix for the new mission is different than that analyzed in the FMEF safety analysis report. A reanalysis was performed of three representative accidents for the revised plutonium mix to determine the impact on the safety analysis. Current versions computer codes and meterology data files were used for the analysis. The revised accidents were a criticality, an explosion in a glovebox, and a tornado. The analysis concluded that risk guidelines were met with the revised plutonium mix.

1997-11-18

3

Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another ...

1999-09-20

4

Reliability assessment of shut-off rod drive mechanism for TAPP - 3 and 4 and critical facility through life cycle testing  

International Nuclear Information System (INIS)

Shut-off rod drive mechanism forms a safety critical system of a nuclear reactor. It is the space constraints for the given reactor layout, which makes design of shut-off rod drive mechanism (SRDM) a custom built design. Design of SRDM adopts fail-safe, replaceability and the simplicity criterion ensuring very high reliability of its operation. Shut-off rod drive mechanism for TAPP-3 and 4 and 'Critical Facility' have been recently designed and developed at Division of Remote Handling and Robotics (DRHR), BARC. These are designed with a number of advanced features and these are significantly different than those used in Dhruva and 220 MWe PHWRs. Design of SRDM is qualified through proto typing and life cycle testing on a full-scale test set-up. This paper gives details of qualification and life cycle test data for prototype SRDM for TAPP-3 and 4 and 'Critical ...

2005-12-01

5

Criticality safety analysis for mockup facility  

Energy Technology Data Exchange (ETDEWEB)

Benchmark calculations for SCALE4.4 CSAS6 module have been performed for 31 UO{sub 2} fuel, 15MOX fuel and 10 metal material criticality experiments and then calculation biases of the SCALE 4.4 CSAS6 module have been revealed to be 0.00982, 0.00579 and 0.02347, respectively. When CSAS6 is applied to the criticality safety analysis for the mockup facility in which several kinds of nuclear material components are included, the calculation bias of CSAS6 is conservatively taken to be 0.02347. With the aid of this benchmarked code system, criticality safety analyses for the mockup facility at normal and hypothetical accidental conditions have been carried out. It appears that the maximum K{sub eff} is 0.28356 well below than the critical limit, K{sub eff}=0.95 at normal condition. In a hypothetical accidental condition, the ...

2000-03-01

6

Criticality experiments: analysis, evaluation, and programs. 6. CORAL-I Reactor: Evaluation of Critical Experiments and Mass Reactivity Coefficient Measurement  

International Nuclear Information System (INIS)

CORAL-I was an experimental, zero-power, fast-spectrum, high-enriched metal uranium reactor that operated from 1968 until 1988 at the former Junta de Energia Nuclear (JEN), CIEMAT at present. The critical measurements performed at the startup of the reactor are being evaluated as part of the International Critical Safety Benchmark Evaluation Program (ICSBEP) and proposed to be included in its 2001 edition. Additionally, the measurement of the mass reactivity coefficient is compared with MCNP4B calculations. This measurement allows one to perform the approach to critical without the need of a previous control rod calibration, thus enhancing the safety of such an approach. This technique can also be applied to other reactor types. CORAL-I (Ref. 1) is a 90% enriched metal uranium reactor domestically designed and manufactured in the experimental facilities of JEN, ...

2001-06-17

7

ORALLOY (93.2 235U) METAL CYLINDER WITH BERYLLIUM TOP REFLECTOR  

International Nuclear Information System (INIS)

A variety of critical experiments were constructed of enriched uranium metal during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, one experiment was comprised of a stack of approximately 7-inch-diameter metal discs. The bottom of ...

10

Preliminary assessment of existing experimental data for validation ofreactor physics codes and data for NGNP design and analysis.  

Energy Technology Data Exchange (ETDEWEB)

The Next Generation Nuclear Plant (NGNP), a demonstration reactor and hydrogen production facility proposed for construction at the INEEL, is expected to be a high-temperature gas-cooled reactor (HTGR). Computer codes used in design and safety analysis for the NGNP must be benchmarked against experimental data. The INEEL and ANL have examined information about several past and present experimental and prototypical facilities based on HTGR concepts to assess the potential of these facilities for use in this benchmarking effort. Both reactors and critical facilities applicable to pebble-bed and prismatic block-type cores have been considered. Four facilities--HTR-PROTEUS, HTR-10, ASTRA, and AVR--appear to have the greatest potential for use in benchmarking codes for pebble-bed reactors. Similarly, for the prismatic block-type reactor design, ...

2005-10-25

11

ORALLOY (93.15 235U) METAL ANNULI WITH BERYLLIUM CORE  

International Nuclear Information System (INIS)

A variety of critical experiments were constructed of enriched uranium metal during the 1960s and 1970s at the Oak Ridge Critical Experiments Facility (ORCEF) in support of criticality safety operations at the Y-12 Plant. The purposes of these experiments included the evaluation of storage, casting, and handling limits for the Y-12 Plant and providing data for verification of calculation methods and cross-sections for nuclear criticality safety applications. These included solid cylinders of various diameters, annuli of various inner and outer diameters, two and three interacting cylinders of various diameters, and graphite and polyethylene reflected cylinders and annuli. Of the hundreds of delayed critical experiments, two were performed that consisted of uranium metal annuli with a solid beryllium metal core. The outer ...

12

TRIGA spent fuel bundles safe storage  

International Nuclear Information System (INIS)

TRIGA-SSR is a steady state research and material test reactor that has been in operation since 1980. The original TRIGA fuel was HEU (highly enriched uranium) with a U"2"3"5 enrichment of 93 per cent. Almost all TRIGA HEU fuel bundles are now burned-up. Part of the spent fuel was loaded and transferred to US, in a Romania - DOE arrangement. The rest of the TRIGA fuel bundles have to be temporarily stored in the TRIGA facility. As the storage conditions had to be established with caution, neutron and thermal hydraulic evaluations of the storage conditions were required. Some criticality evaluations were made based on the SAR (Safety Analysis Report) data. Fuel constant axial temperature approximation effect is usual for criticality computations. TRIGA-SSR fuel bundle geometry and materials model for SCALE5-CSAS module allows the introduction of a fuel temperature dependency for the entire fuel active ...

2007-05-13

13

Decommissioning of facility for use of radioisotopes on waste management and disposal facility  

Energy Technology Data Exchange (ETDEWEB)

All the tests have been finished up in the Waste Management and Disposal Facility which has been used for the safety tests of solidified radioactive waste on sea dumping disposal. The decommissioning of this facility was performed for use of radioisotopes. This report describes the plan on decommissioning of facility for use of radioisotopes, the contamination checking methods and measurement of radioactivity, the fore case and practice for amount of generated radioactive wastes, the operation procedures for dismantlement, the safety measures, the expenses for decommissioning and so on. (author)

1999-09-01

14

Cold vacuum drying facility design requirements; FINAL  

International Nuclear Information System (INIS)

This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.

15

The US Advanced Liquid Metal Reactor and the Fast Flux Test Facility Phase IIA passive safety tests  

International Nuclear Information System (INIS)

This report discusses the safety approach of the Advanced Liquid Metal reactor program, sponsored by the US Department of Energy, which relies upon passive reactor responses to off-normal condition to limit power and temperature excursions to levels that allow safety margins. Gas expansion modules (GEM) have included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Preapplication safety evaluations by the US Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned ...

1992-10-25

16

The U.S. Advanced Liquid Metal Reactor and the fast flux test facility phase IIA passive safety tests  

International Nuclear Information System (INIS)

The safety approach of the Advanced Liquid Metal Reactor program, sponsored by the U.S. Department of Energy, relies upon passive reactor responses to off-normal conditions to limit power and temperature excursions to levels that allow large safety margins. Gas expansion modules (GEM) have been included in the design to provide negative reactivity to enhance these margins in the extremely unlikely event that pumping power is lost and the highly reliable scram system fails to operate. The feasibility and beneficial features of these devices were first demonstrated in the core of the Fast Flux Test Facility (FFTF) in 1986. Pre-application safety evaluations by the U.S. Nuclear Regulatory Commission have identified areas that must be addressed if these devices are to be relied on. One of these areas is the response of the reactor when it is critical and the pumps are turned on, ...

17

Different aspects of safety in Nuclear Fuel Plant at Pitesti, Romania  

International Nuclear Information System (INIS)

Nuclear Fuel Plant (FCN) is a facility that produces fuel bundles of CANDU-6 type for the CANDU nuclear power plant. Only natural and depleted uranium in bulk and itemized form are present as nuclear materials in this facility. Uranium and wastes from the plant are handled, processed, treated and stored throughout the entire facility. The nuclear materials with natural and depleted uranium are entirely under nuclear safeguards. The amount of uranium present in the plant in different forms and activities together with zircaloy, beryllium and other hazardous substances, wastes, explosive materials at high temperatures, etc. lead to special measures undertaken by Nuclear Safety Department (DNS) to ensure nuclear safety. Different aspects of safety are continuously monitored in the plant: operational safety, industrial ...

2009-10-12

18

New developments in dry spent fuel storage  

International Nuclear Information System (INIS)

As shown in various new examples, HABOG facility (Netherlands), CERNAVODA (Candu - Romania), KOZLODUY (WWER - Bulgaria), CHERNOBYL ( RMBK - Ukraine), MAYAK (Spent Fuel from submarine and Icebreakers - Russia), recent studies allow to confirm the flexibility and performances of the CASCAD system proposed by SGN, both in safety and operability, for the dry storage of main kinds of spent fuel. The main features are: A multiple containment barrier system: as required by international regulation, 2 independent barriers are provided (tight canister and storage pit); Passive cooling, while the Fuel Assemblies are stored in an inert atmosphere and under conditions of temperature preventing from degradation of rod cladding; Sub-criticality controlled by adequate arrangements in any conditions; Safe facility meeting ICPR 60 Requirements as well as all applicable regulations (including severe weather conditions ...

2001-06-18

19

Decree of the Czechoslovak Atomic Energy Commission No. 436/1990 on quality assurance of selected facilities with respect to nuclear safety of nuclear facilities  

International Nuclear Information System (INIS)

The Decree specifies basic quality assurance requirements applicable to machines, their parts and materials, civil engineering structures, means for automated control of technological processes including hardware and software, and electricity supply systems related to nuclear safety of nuclear facilities, and stipulates binding procedures for the implementation of technical and organizational provisions associated with the quality of selected equipment to ensure nuclear safety of nuclear facilities. Safety classes are defined for selected equipment. Requirements laid on safety assurance documentation are specified, and requirements placed on safety assurance programmes, their preparation, finalization and approval are defined. Quality assurance requirements are also specified with respect to the designing, manufacture, construction, ...

1995-02-01

20

Hot Cell Facility (HCF) Safety Analysis Report  

Energy Technology Data Exchange (ETDEWEB)

This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important ...

2000-11-01

21

Preliminary investigation of the /sup 252/Cf-source-driven noise analysis method of subcriticality measurement in LWR fuel storage and initial loading applications  

Energy Technology Data Exchange (ETDEWEB)

The ability of the /sup 252/Cf-source-driven neutron noise analysis method to measure subcriticality has been demonstrated in a variety of experimental configurations of fissile materials. Calculations for an approximately 4-m-dia configuration of light water reactor (LWR) fuel elements indicated the feasibility of measuring the subcriticality of large, loosely coupled arrays of LWR fuel elements by this same method. These analysis suggested application to the initial loading of both pressurized and boiling water reactors, zero-power testing of reactors (such as shutdown margin measurements after initial loading), light water reactor refueling, and safe storage of LWR spent fuel. In the fuel storage application, direct measurement of subcriticality in the actual fuel storage facilities provides the parameter which is directly related to criticality safety.

1984-01-01

22

Cold Vacuum Drying (CVD) Facility Technical Safety Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Technical Safety Requirements (TSRs) for the Cold Vacuum Drying Facility define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation. Controls required for public safety, significant defense-in-depth, significant worker safety, and for maintaining radiological and toxicological consequences below risk evaluation guidelines are included.

1999-12-16

23

Subcritical Noise Analysis Measurements with Fresh and Spent Research Reactor Fuels Elements  

Energy Technology Data Exchange (ETDEWEB)

The verification of the subcriticality is of utmost importance for the safe transportation and storage of nuclear reactor fuels. Transportation containers and storage facilities are designed such that nuclear fuels remain in a subcritical state. Such designs often involve excess conservatism because of the lack of relevant experimental data to verify the accuracy of Monte Carlo codes used in nuclear criticality safety analyses. A joint experimental research program between Oak Ridge National Laboratory, Westinghouse Safety Management Solutions, Inc., and the University of Missouri was initiated to obtain measured quantities that could be directly related to the subcriticality of simple arrays of Missouri University Research Reactor (MURR) fuel elements. A series of measurement were performed to assess the reactivity of materials such as BORAL, stainless steel, aluminum, and lead that are typically used ...

1999-02-01

24

Performance Testing Methodology for Safety-Critical Programmable Logic Controller  

International Nuclear Information System (INIS)

The Programmable Logic Controller (PLC) for use in Nuclear Power Plant safety-related applications is being developed and tested first time in Korea. This safety-related PLC is being developed with requirements of regulatory guideline and industry standards for safety system. To test that the quality of the developed PLC is sufficient to be used in safety critical system, document review and various product testings were performed over the development documents for S/W, H/W, and V/V. This paper provides the performance testing methodology and its effectiveness for PLC platform conducted by KOPEC

2009-05-01

25

MANAGEMENT PRE-START REVIEW FINAL REPORT FOR THE BIOSAFETY LEVEL 3 (BSL-3) FACILITY (B368) LAWRENCE LIVERMORE NATIONAL LABORATORY  

Energy Technology Data Exchange (ETDEWEB)

A Lawrence Livermore National Laboratory (LLNL) Management Pre-Start Review (MPR) Team was formed to independently verify the operational readiness of Building 368 (B368) Biosafety Level III (BSL-3) Facility to conduct research with biological pathogens and toxins including those considered Select Agents. Review objectives and criteria were developed from the DOE/NNSA and LLNL requirements. These were provided in the Implementation Plan for the Biosafety Level III (BSL-3) Facility Management Pre-Start Review (BSL-3 MPR) at Lawrence Livermore National Laboratory that was reviewed and approved by DOE/NNSA-LSO. The formal part of the LLNL MPR for the BSL-3 Facility was begun in August of 2005 but work on the MPR was stopped in October of 2005 due to the need for LLNL to reassess organizational and operational controls and respond to Centers for Disease Control and Prevention inquiries related to a shipping incident involving ...

2006-07-25

26

Shielding and Criticality Safety Analysis of KSC-1 Cask for the High Burnup PWR Spent Fuels  

International Nuclear Information System (INIS)

KSC-1 (KAERI Shipping Cask-1) was designed and manufactured with a pure domestic technology in 1985 in order to transport a PWR spent fuel assembly from nuclear power plant to PIEF (Post-Irradiation Examination Facility) of KAERI. Since the first transportation of the fuel assembly from Kori-1 NPP was carried out by the cask in 1987, 19 shipments for the PWR spent fuels have been done successfully by now. Maximum discharge burnup of PWR in Korea has been extended from the late 1990s in order to reduce the cost of power generation. From this cause, allowable design values of the initial enrichment and the cooling time for the cask have been changed three times: year 2003, 2007 and 2010. Radiation shielding and criticality of KSC-1 were analyzed for all the PWR fuel type irradiated in Korea NPP to renew the design approval

2010-10-01

27

In field nuclear forensics: An overview of applicable instrumentation  

International Nuclear Information System (INIS)

Recent seizures of nuclear materials, and particularly of fissionable nuclear materials, have resulted in an increased awareness of the need for fieldable instrumentation for the detection and characterization of suspect packages and materials. The ability to perform in-field assessments of materials contained in suspect packages is important for several reasons. First, and most importantly, determination of the type and quantity of material provides information critical to personnel safety. The personnel at potential risk may include both the general population in the area of the package and incident response personnel. Additionally, it would be advantageous to gain information that could result in attribution of the suspect package to a particular facility or pathway as soon as possible after interception. Limited access to a suspect package could also require the use of fieldable characterization instrumentation as ...

1997-06-12

28

An overview of FFTF [Fast Flux Test Facility] contributions to Liquid Metal Reactor Safety  

International Nuclear Information System (INIS)

The Fast Flux Test Facility has provided a very useful framework for testing the advances in Liquid Metal Reactor Safety Technology. During the licensing phase, the switch from a nonmechanistic bounding technique to the mechanistic approach was developed and implemented. During the operational phase, the consideration of new tests and core configurations led to use of the anticipated-transients-without-scram approach for beyond design basis events and the move towards passive safety. The future role of the Fast Flux Test Facility may involve additional passive safety and waste transmutation tests. 26 refs.

1990-11-11

29

Subcriticality calculations for the FFTF reverse approach to critical experiment  

Science.gov (United States)

The reverse approach to critical (RAC) experiments were performed in the ZPR-IX critical facility at Argonne National Laboratory. One of the major objectives of this project is to determine the adequacy of the low-level flux monitor (LLFM) detectors for initial loading of the Fast Flux Test Facility (FFTF). 5 references. (auth)

1975-01-01

30

American National Standard ANSI/ANS-8.15-1983: Nuclear criticality control of special actinide elements  

Energy Technology Data Exchange (ETDEWEB)

The American National Standard, `Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors` ANSI/ANS-8.1- 1983 provides guidance for the nuclides [sup 233]U, [sup 235]U, and [sup 239]Pu These three nuclides are of primary interest in out-of-reactor criticality safety since they are the most commonly encountered in the vast majority of operations. However, some operations can involve nuclides other than `U, `U, and `Pu in sufficient quantities that their effect on criticality safety could be of concern. The American National Standard, `Nuclear Criticality Control of Special Actinide Elements` ANSI/ANS-8.`15-1983 (Ref 2), provides guidance for fifteen such nuclides.

1996-12-31

31

Interim safety basis for fuel supply shutdown facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB in conjunction with the new TSRs, will provide the required basis for interim operation or restrictions on interim operations and administrative controls for the Facility until a SAR is prepared in accordance with the new requirements. It is concluded that the risk associated with the current operational mode of the Facility, uranium closure, clean up, and transition activities required for permanent closure, are within Risk Acceptance Guidelines. The Facility is classified as a Moderate Hazard Facility because of the potential for an unmitigated fire associated with the uranium storage buildings.

1995-05-23

32

Role and responsibilities of Technical Support Division (TSD) of National Nuclear Safety Department (NNSD) in licensing process  

International Nuclear Information System (INIS)

National Nuclear Safety Department is authorized by Infra (Iranian Nuclear Regulatory Authority) for issuing rules and regulation and conducting the licensing and supervisory process for nuclear facilities. The main responsibilities of the NNSD are conducted via five main division are, nuclear codes and standards, Nuclear Safety assessment, Authorization, Inspection and Enforcement and Technical Support. In this paper, the functions and responsibilities of TSD in enhancing nuclear safety are described. Examples of main tasks to support the Nuclear Safety assessment division regarding to technical calculations and research of safety issues in licensing documents are provided. (author)

2007-08-01

33

Development of LMFBR safety testing in FFTF  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) will provide a prototypic test environment for advanced fuels and materials development within the U. S. LMFBR program. As a fast test reactor, the FFTF also provides a potentially unique capability for conduct of safety experimentation relevant to selected LMFBR safety issues associated with postulated core disruption events. The utility and feasibility of possible extension of FFTF testing into the area of safety research is being investigated. 5 fig.

1976-10-01

34

Dose consequences from a postulated criticality occurring in a low-level waste disposal facility  

Energy Technology Data Exchange (ETDEWEB)

Evaluations were done to determine conditions that could permit nuclear criticality with fissile uranium in low-level waste (LLW) facilities and to estimate potential radiation exposures to personnel if there were such an accident. Simultaneous hydrogeochemical and nuclear criticality studies were done (1) to identity realistic scenarios for uranium migration and concentration increase at LLW disposal facilities, (2) to model groundwater transport of uranium and subsequent concentration via sorption or precipitation, (3) to evaluate the potential for nuclear criticality resulting from potential increases in uranium concentration over disposal limits, and (4) to estimate potential radiation exposures to personnel resulting from criticality consequences. This paper presents the details of the radiation exposure calculations relying on the conditions as determined ...

1997-12-01

35

Facility Safety Plan B360 Complex Biohazardous Operations CMLS-412r0  

Science.gov (United States)

This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.

2007-01-08

36

Department of Nuclear Safety Research and Nuclear Facilities annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The report presents a summary of the work of the Department of Nuclear Safety Research and Nuclear Facilities in 1995. The department`s research and development activities are organized in three research programmes: Radiation Protection, Reactor Safety, and Radioanalytical Chemistry. The nuclear facilities operated by the department include the Research Reactor DR3, the Isotope Laboratory, the Waste Treatment Plant, and the Educational Reactor DR1. Lists of staff and publications are included together with a summary of the staff`s participation in national and international committees. (au) 5 tabs., 21 ills.

1996-03-01

37

Criticality safety review of FFTF interim decay storage tank  

Science.gov (United States)

The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)

1975-10-01

38

American National Standard ANSI/ANS-8.6: Safety in conducting subcritical neutron-multiplication measurements {open_quote}In Situ{close_quote}  

Energy Technology Data Exchange (ETDEWEB)

Safe and economical operations with fissile materials require knowledge of the subcriticality of configurations that arise in material processing, storage, and transportation. Data from critical experiments have been a principal source of information with which to establish safety margins. However, the lower cost and the expediency of performing confirmatory subcritical measurements on the process floor or in the storage vault resulted in much of the early criticality safety guidance being based on subcritical in situ experiments.

1996-10-01

39

Interim Safety Basis for Fuel Supply Shutdown Facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB, in conjunction with the IOSR, provides the required basis for interim operation or restrictions on interim operations and administrative controls for the facility until a SAR is prepared in accordance with the new requirements or the facility is shut down. It is concluded that the risks associated with tha current and anticipated mode of the facility, uranium disposition, clean up, and transition activities required for permanent closure, are within risk guidelines.

2000-09-07

40

The technology of high-temperature reactors. Design, construction, commissioning, operation of the Juelich AVR and the THTR-300; Die Technik der Hochtemperaturreaktoren. Konstruktion - Bau - Inbetriebnahme - Betrieb des AVR Juelich und des THTR-300  

Energy Technology Data Exchange (ETDEWEB)

The AVR experimental nuclear reactor was Professor Dr. Rudolf Schulten's brainchild. Visionary ideas led to the success of this technology: - Helium coolant because of the particularly high heat transfer coefficients; - an integrated primary system reactor concept as the basis of all safety considerations in the interest of maximum safety; - uranium-235 and thorium-232 fuel allowing new fuel to be bred; - high temperatures for electricity generation at maximum thermodynamic efficiencies, i.e. optimum fuel utilization; - the possibility to run chemical processes economically at high temperatures by means of nuclear fuels; - the inherent safety of the reactor, for a major accident accompanied by a complete loss of cooling cannot occur for nuclear physics reasons, as was tested twice in the AVR. The AVR attained its first criticality on August 28, 1968. It was operated for more than 20 years, ...

2009-12-15

41

The technology of high-temperature reactors. Design, construction, commissioning, operation of the Juelich AVR and the THTR-300  

International Nuclear Information System (INIS)

The AVR experimental nuclear reactor was Professor Dr. Rudolf Schulten's brainchild. Visionary ideas led to the success of this technology: - Helium coolant because of the particularly high heat transfer coefficients; - an integrated primary system reactor concept as the basis of all safety considerations in the interest of maximum safety; - uranium-235 and thorium-232 fuel allowing new fuel to be bred; - high temperatures for electricity generation at maximum thermodynamic efficiencies, i.e. optimum fuel utilization; - the possibility to run chemical processes economically at high temperatures by means of nuclear fuels; - the inherent safety of the reactor, for a major accident accompanied by a complete loss of cooling cannot occur for nuclear physics reasons, as was tested twice in the AVR. The AVR attained its first criticality on August 28, 1968. It was operated for more than 20 years, until ...

2009-12-01

42

Plutonium Finishing Plant safety evaluation report  

Energy Technology Data Exchange (ETDEWEB)

The Plutonium Finishing Plant (PFP) previously known as the Plutonium Process and Storage Facility, or Z-Plant, was built and put into operation in 1949. Since 1949 PFP has been used for various processing missions, including plutonium purification, oxide production, metal production, parts fabrication, plutonium recovery, and the recovery of americium (Am-241). The PFP has also been used for receipt and large scale storage of plutonium scrap and product materials. The PFP Final Safety Analysis Report (FSAR) was prepared by WHC to document the hazards associated with the facility, present safety analyses of potential accident scenarios, and demonstrate the adequacy of safety class structures, systems, and components (SSCs) and operational safety requirements (OSRs) necessary to eliminate, control, or mitigate the identified hazards. Documented in this ...

1995-01-01

43

Regulatory quality assurance requirements for the operation of nuclear R and D facilities in Korea  

International Nuclear Information System (INIS)

Full text: Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation. including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently. nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. All provisions on nuclear safety regulation and radiation protection are entrusted to the Atomic ...

2006-10-15

44

The safety issues of medical robotics  

International Nuclear Information System (INIS)

In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for ...

2001-08-01

45

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

46

Investigation of Nuclide Importance to Functional Requirements Related to Transport and Long-Term Storage of LWR Spent Fuel  

Energy Technology Data Exchange (ETDEWEB)

The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion ...

1995-01-01

47

Analysis and decision document in support of acquisition of steam supply for the Hanford 200 Area  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) is now evaluating its facility requirements in support of its cleanup mission at Hanford. One of the early findings is that the 200-Area steam plants, constructed in 1943, will not meet future space heating and process needs. Because the 200 Area will serve as the primary area for waste treatment and long-term storage, a reliable steam supply is a critical element of Hanford operations. This Analysis and Decision Document (ADD) is a preliminary review of the steam supply options available to the DOE. The ADD contains a comprehensive evaluation of the two major acquisition options: line-term versus privatization. It addresses the life-cycle costs associated with each alternative, as well as factors such as contracting requirements and the impact of market, safety, security, and regulatory issues. Specifically, this ADD documents current and future steam requirements for the 200 Area, ...

1992-02-01

48

A review of Monte Carlo criticality calculations - Convergence, bias, statistics  

International Nuclear Information System (INIS)

Monte Carlo criticality calculations have been performed for over 50 years for reactor physics and criticality safety applications. With today's faster computers, these calculations are being carried out to greater precision (smaller uncertainties) in keff, and detailed distributions of power and reaction rates are being computed routinely. This paper provides a review of the fundamental theory of Monte Carlo criticality calculations, with guidance on practical methods for: (1) assuring convergence of both keff and the source distribution, (2) minimizing the bias in keff and reaction rate distributions, and (3) dealing with the under-prediction bias in uncertainties for keff and reaction rate distributions. (authors)

2009-05-03

49

A study to develop the domestic functional requirements of the specific safety systems of CANDU  

Energy Technology Data Exchange (ETDEWEB)

The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SDS-1, SDS2, ECCS, and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.

2003-03-15

50

A study to develop the domestic functional requirements of the specific safety systems of CANDU  

Energy Technology Data Exchange (ETDEWEB)

The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SOS-1, SOS-2, ECCS and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.

2001-03-15

51

Definition and means of maintaining the criticality detectors and alarms portion of the PFP safety envelope  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this document is to provide the definition and means of maintaining the Safety Envelope (SE) related to the Criticality Alarm System (CAS). This document provides amplification of the Limiting Condition for Operation (LCO) described in the Plutonium Finishing Plant (PFP) Operational Safety Requirements (OSR), WHC-SD-CP-OSR-010, Rev. 0, 1994, Section 3.1.2, Criticality Detectors and Alarms. This document, with its appendices, provides the following: (1) System functional requirements for determining system operability (Section 3); (2) A list of annotated system block diagrams which indicate the safety envelope boundaries (Appendix C); (3) A list of the Safety Class 1 and 2 Safety Envelope (SC-1/2 SE) equipment for input into the Master Component Index (Appendix B); (4) Functional requirements for individual SC-1/2 SE ...

1997-05-13

52

Resolution of key safety-related issues in FFTF regulatory review  

International Nuclear Information System (INIS)

The FFTF is an ERDA facility which does not require licensing, but a technical review by NRC is required by ERDA policy. Safety issues which were not fully resolved in the course of the review for construction authorization have been the subject of continuing review since mid-1973. These issues included HCDA energetics, design fallback provisions for additional safety margins, piping integrity, and natural circulation core cooling.

53

Advanced Simulation & Computing FY09-FY10 Implementation Plan Volume 2, Rev. 0  

Energy Technology Data Exchange (ETDEWEB)

The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the safety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with current and future nonnuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing Program (ASC)1 is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile ...

2008-04-30

54

High-explosives test facility  

Energy Technology Data Exchange (ETDEWEB)

This report describes a high explosives test facility that makes efficient use of equipment and combines utility, convenience, and safety in a modest amount of space. It is a dedicated facility for exploratory development efforts that previously were conducted in a single room having very limited capabilities. Two explosives testing areas are now available and several projects are supported concurrently.

1982-08-01

55

Gun Shot Wound to the Chest of a Military Working Dog.  

Science.gov (United States)

This Military Working Dog (MWD) was shot in the chest during combat operations in Iraq. Military Working Dogs are critical to the safety and well- being of deployed troops in combat operations and, as such, they are triaged and treated in our combat hospi...

2009-01-01

56

Review of Regulatory Quality Assurance Requirements for the Operation of Nuclear R and D Facilities  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation, including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently, nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/ contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. In this paper, the context of amended Atomic Energy laws were reviewed to confirm quality assurance measures and identify additional ...

2005-10-27

57

Nuclear criticality safety experiments, calculations, and analyses - 1958 to 1982. Volume 2. Summaries. Complilation of papers from the Transactions of the American Nuclear Society  

Energy Technology Data Exchange (ETDEWEB)

This compilation contains 688 complete summaries of papers on nuclear criticality safety as presented at meetings of the American Nuclear Society (ANS). The selected papers contain criticality parameters for fissile materials derived from experiments and calculations, as well as criticality safety analyses for fissile material processing, transport, and storage. The compilation was developed as a component of the Nuclear Criticality Information System (NCIS) now under development at the Lawrence Livermore National Laboratory. The compilation is presented in two volumes: Volume 1 contains a directory to the ANS Transaction volume and page number where each summary was originally published, the author concordance, and the subject concordance derived from the keyphrases in titles. Volume 2 contains-in chronological order-the full-text summaries, reproduced here by ...

1982-10-21

58

The KSNPP risk-effect analysis of the digital safety-critical systems  

Energy Technology Data Exchange (ETDEWEB)

The study was performed for evaluating the risk effect of digital systems on the total plant. Based on risk monitor, a fault tree model for the Korean Standard Nuclear Power Plants (KSNPP), we integrate the fault-tree models for Digital Plant Protection System (DPPS) and Digital Engineered SaFety Actuation System (DESFAS) which are the most important safety-critical I and C systems in the KSNPP. In this study, however, three important factors (the probabilities of manual actuation failure, the software failure probability, and the watchdog timer fault coverage) are treated as the variables of the sensitivity study because quantification methodologies for these factors are not developed yet. Not only the unavailability of digital safety-critical system itself, but also the risk effect of digital systems on the total plant should be assessed to prove the safety of digital systems. The result of ...

2004-02-01

59

Hazard analysis for 300 Area N Reactor Fuel Fabrication and Storage Facilty  

Energy Technology Data Exchange (ETDEWEB)

This hazard analysis (HA) has been prepared for the 300 Area N Reactor Fuel Fabrication and Storage Facility (Facility), in compliance with the requirements of Westinghouse Hanford Company (Westinghouse Hanford) controlled manual WHC-CM-4-46, Nonreactor Facility Safety Analysis Manual, and to the direction of WHC-IP-0690, Safety Analysis and Regulation Desk Instructions, (WHC 1992). An HA identifies potentially hazardous conditions in a facility and the associated potential accident scenarios. Unlike the Facility hazard classification documented in WHC-SD-NR-HC-004, Hazard Classification for 300 Area N Reactor Fuel Fabrication and Storage Facility, (Huang 1993), which is based on unmitigated consequences, credit is taken in an HA for administrative controls or engineered safety features planned or in ...

1994-01-25

60

Navy Occupational Health Information Management System (NOHIMS). Hazardous Materials Control Module. Users' manual  

Energy Technology Data Exchange (ETDEWEB)

The Hazardous Materials Control Module (HMC) is one module of four for the Industrial Health component. The HMC module was designed to inform employees of health and safety hazards in the workplace and to track the movement of hazardous materials through the facility. The module performs these functions by maintaining health and safety data on hazardous materials used in the facility, and by tracking who requests information about any hazardous materials. The HMC module gets its information from two sources. The first one is the Hazardous Materials Information System (HMIS), this is a national system that is used by the Department of Defense. It is loaded on to the system via tapes that contain all safety, health and transportation information about a particular product. The second is Material Safety Data Sheets (MSDS) that are procured by a particular site. ...

1987-01-16

61

Advice about the safety of graphite storage silos of Saint Laurent des Eaux facility; Avis sur la surete des silos de stockage de graphite de Saint Laurent des Eaux  

Energy Technology Data Exchange (ETDEWEB)

This document is the safety analysis made by the national association of the local commissions of information about nuclear activities (ANCLI), about the safety of graphite storage silos of Saint Laurent des Eaux nuclear facility. The analysis covers: the operation safety and the accident hypothesis, the monitoring of indoor and outdoor contamination in routine situation, the geotechnical characteristics of the site environment, the isotopic inventory and the estimation of radioactivity in routine and accidental situation, the estimation of doses received by the population in accidental situation and the internal emergency plan. After examination of these different points, the scientific committee of the ANCLI considers that a new global evaluation of risks, which integrates more recent exposure data, has to be carried out. (J.S.)

2005-07-01

62

Safety analysis practices for the dense storage of RBMK spent fuel and improved technology for the long term storage of spent fuel in water pools  

International Nuclear Information System (INIS)

The paper discusses the safety problems connected with the conversion to dense storage of RBMK-1000 spent fuel in reactor cooling pools and independent storage facilities. Recourse to dense storage has been made for a number of reasons, among which are the absence of spent fuel shipments from the nuclear power plant site, prolongation of storage time and a partial change in storage conditions. Increasing the storage density per unit volume of the storage facility and turning to new technical procedures (as against the basic design) call for further investigation of safety problems. The safety assessment of the dense storage mode includes: (1) Selecting a list of initiating events for design basis and unforeseeable accidents; (2) Assessing dense storage safety under normal as well as design basis accident conditions; (3) Safety analysis and ...

1995-08-01

63

Developing a regulatory performance assessment approach for geological disposal of spent nuclear fuel  

International Nuclear Information System (INIS)

To be able to carry out review functions regulatory authorities must be able to make critical evaluations of proponent's safety cases. In Sweden the Swedish Radiation Safety Authority aims to have in place its own suite of performance assessment tools. This paper looks at the role and application of a regulator's models to important features of current modelling in a proponent's performance assessment. (authors)

64

Characteristics of safety critical organizations . work psychological perspective  

International Nuclear Information System (INIS)

This book deals with organizations that operate in high hazard industries, such as the nuclear power, aviation, oil and chemical industry organisations. The society puts a great strain on these organisations to rigorously manage the risks inherent in the technology they use and the products they produce. In this book, an organisational psychology view is taken to analyse what are the typical challenges of daily work in these environments. The analysis is based on a literature review about human and organisational factors in safety critical industries, and on the interviews of Finnish safety experts and safety managers from four different companies. In addition to this, personnel interviews conducted in the Finnish nuclear power plants are utilised. The authors come up with eight themes that seem to be common organizational challenges cross the industries. These include e.g. how does the personnel ...

65

Los Alamos DP West Plutonium Facility decontamination project  

Energy Technology Data Exchange (ETDEWEB)

The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation.

1982-01-01

66

Safety significance of ATR passive safety response attributes  

International Nuclear Information System (INIS)

The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety of the facility. The three passive safety attributes being evaluated in the paper are: 1) In-core and in-vessel natural convection cooling, 2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and 3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond to most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk ...

1990-03-01

67

Assessment of radiological safety of Wolsung site at site boundary considering crack impact  

British Library Electronic Table of Contents (United Kingdom)

The number of spent fuel storage facilities in the world continues to increase because of "Wait and See" policies and delay of a permanent disposal plan. The temporary spent fuel storage concept is changing to a pre-disposal storage concept. Strengthened safety concepts are required for expanded spent fuel storage facilities and sites. The Korea Hydro and Nuclear Power Company is planning to construct a reinforced concrete MACSTOR-400 facility at Wolsung. In concrete dry spent fuel storage structures, cracks can occur due to radiant heat and environmental chloride. The likelihood of cracking increases over time. Research on changes in shielding performance from one collinear crack in the surface of a concrete facility has been carried out. However there is no research about public radiolog...

2010-01-01

68

Advanced Simulation and Computing FY10-FY11 Implementation Plan Volume 2, Rev. 0.5  

Energy Technology Data Exchange (ETDEWEB)

The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the surety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with current and future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering (D&E) programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program requires the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing Program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment ...

2009-09-08

69

Effective multiplication factor measurement by feynman-{alpha} method. 3  

Energy Technology Data Exchange (ETDEWEB)

The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The ...

1998-06-01

70

Automation in a material processing/storage facility  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site (SRS) is currently developing a new facility, the Actinide Packaging and Storage Facility (APSF), to process and store legacy materials from the United States nuclear stockpile. A variety of materials, with a variety of properties, packaging and handling/storage requirements, will be processed and stored at the facility. Since these materials are hazardous and radioactive, automation will be used to minimize worker exposure. Other benefits derived from automation of the facility include increased throughput capacity and enhanced security. The diversity of materials and packaging geometries to be handled poses challenges to the automation of facility processes. In addition, the nature of the materials to be processed underscores the need for safety, reliability and serviceability. The application of automation in this ...

1997-05-01

71

VDMA contribution to functional safety of turbo-machines - A necessary risk reduction by means of safety function for steam turbines; VDMA-Beitrag zur Funktionalen Sicherheit von Turbomaschinen. Notwendige Risikoreduktion durch Schutzfunktionen fuer Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.

2010-07-01

72

H/sub 2/S safety aboard an offshore production facility handling crude oil and associated sour natural gas  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety system and training for personnel on board the floating production storage and offloading (FPSO II) currently working in the Cadlao Field, offshore Palawan in the Philippine Islands. (See Figure 1). The crude oil being produced has wellstream hydrogen sulfide concentrations up to 6000 PPM. Concentrations of hydrogen sulfide at 700 PPM or higher can be immediately dangerous to life and every effort must be made to ensure personnel safety.

1984-02-01

73

Quality assurance requirements for the design of nuclear fuel reprocessing facilities  

International Nuclear Information System (INIS)

Requirements and guidance are provided for a quality assurance program for the design of nuclear fuel reprocessing facilities involving structures, systems and components whose satisfactory performance is required to prevent accidents that could cause undue risk to the health and safety of the public, or to mitigate the consequences of such accidents if they were to occur. The standard is to be used in conjunction with ANSI N46.2.

74

Explosion protection in nuclear power plants with LWR and HTR reactors. As of August 14, 1989. Explosionsschutz in Kernkraftwerken mit Leichtwasser- und Hochtemperaturreaktoren (allgemeine und fallbezogene Anforderungen). Vom 14. August 1989  

Energy Technology Data Exchange (ETDEWEB)

The technical rule intends to maintain the function of the safety facilities in case of explosion hazards resulting from materials capable of generating explosive atmospheres or forming explosive mixtures if such materials are brought or released into the nuclear facility or are generated on site. (orig.).

1989-12-07

75

Explosion protection in nuclear power plants with LWR and HTR reactors (general and case depending requirements). Explosionsschutz in Kernkraftwerken mit Leichtwasser- und Hochtemperaturreaktoren (allgemeine und fallbezogene Anforderungen)  

Energy Technology Data Exchange (ETDEWEB)

The technical rule intends to maintain the function of the safety facilities in case of explosion hazards resulting from materials capable of generating explosive atmospheres or forming explosive mixtures if such materials are brought or released into the nuclear facility or are generated on site. (orig.).

1989-01-01

76

The role of natural circulation in the FFTF [Fast Flux Test Facility] passive safety tests  

International Nuclear Information System (INIS)

A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety.

1987-12-13

77

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

78

Fast Flux Test Facility reactor initial criticality predictions and measurements  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) was designed to test fast-reactor fuels and other nonfuel materials. In its 37 reactor cycles of operations, the FFTF reactor has performed very well and successfully completed all the irradiation testings with an operating efficiency factor as high as 98%. Since FFTF is an experimental reactor, its core loading changed from cycle to cycle. Depending on the number of test assemblies in the core and their location, the core loading can change significantly from an essentially homogeneous core loading to a relatively nonhomogeneous or even highly localized heterogeneous loading. Consequently, the core reload design and initial criticality analyses were required for each operating cycle. The zero power initial critical control rod bank height was predicted before each reactor startup. The initial critical prediction depends on the reactivity conditions at the end of the ...

1992-06-07

79

The Efforts to Utilize High-Temperature Melting Technologies for ILLW and the Development of Guidelines for their Technical Assessment  

Energy Technology Data Exchange (ETDEWEB)

A couple of domestic institutions have been investigating the application of vitrification technology to treat low- and intermediate-level radioactive wastes in Korea. In the case that such investigations prove to be successful, it is expected that commercial vitrification plants will be constructed. The safety insuring on vitrification plants could not be compatible with criterion on radioactive waste management because the facilities are at high temperature and contain a variety of accommodations for the exhaust gases and residual products. Therefore, it is necessary to suggest a new strategy or modifications of criterion of radioactive waste management on considerations related with the vitrification technology. In order to ensure the safety of vitrification plants, a technical guideline or standard for design and operation of vitrification plants must be established too. A study on the safety ...

2003-02-25

80

ORNL results for Test Case 1 of the International Atomic Energy Agency`s research program on the safety assessment of Near-Surface Radioactive Waste Disposal Facilities  

Energy Technology Data Exchange (ETDEWEB)

The International Atomic Energy Agency (IAEA) started the Coordinated Research Program entitled ```The Safety Assessment of Near-Surface Radioactive Waste Disposal Facilities.`` The program is aimed at improving the confidence in the modeling results for safety assessments of waste disposal facilities. The program has been given the acronym NSARS (Near-Surface Radioactive Waste Disposal Safety Assessment Reliability Study) for ease of reference. The purpose of this report is to present the ORNL modeling results for the first test case (i.e., Test Case 1) of the IAEA NSARS program. Test Case 1 is based on near-surface disposal of radionuclides that are subsequently leached to a saturated-sand aquifer. Exposure to radionuclides results from use of a well screened in the aquifer and from intrusion into the repository. Two repository concepts were defined in Test Case 1: a simple earth ...

1993-07-01

81

Alteration of installation of reactors (alteration of No. 1 and No. 2 reactor facilities) in the Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The Nuclear Safety Commission presented the report to the Minister of International Trade and Industry on April 5, 1984, after the careful investigation and deliberation on the alteration of installation of No.1 and No.2 reactor facilities in the Sendai Nuclear Power Station. The technical capability of Kyushu Electric Power Co., Inc., was recognized to be adequate. It was judged that the safety after this alteration of installation of the reactor facilities can be ensured. The main items of examination were as follows. The mechanical, nuclear and thermo-hydraulic designs of 17 x 17 B-type fuel assemblies were regarded as adequate. The coexistence of A-type and B-type fuel assemblies does not cause any problem about the safety. The safety at the time of abnormal transient change and accident in the mixed fuel assembly core was confirmed. In No.2 reactor, the ...

1984-08-01

82

The automatic programming for safety-critical software in nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

We defined the Korean unique safety-critical software development methodology by modifying Dr. Harel`s statechart-based on formal methods in order to digitalized the reactor protection system. It is suggested software requirement specification guideline to specify design specification which is basis for requirement specification and automatic programming by the caused by shutdown parameter logic of the steam generator water level for Wolsung 2/3/4 unit SDS no.1 and simulated it by binding the Graphic User Interface (GUI). We generated the K and R C code automatically by utilizing the Statemate MAGNUM Sharpshooter/C code generator. Auto-generated K and R C code is machine independent code and has high productivity, quality and provability. The following are the summaries of major research and development. - Set up the Korean unique safety-critical software development methodology - Developed software requirement specification guidelines - ...

1998-06-01

83

Development of a system model for the postclosure assessment of a concept for geological disposal of Canada`s nuclear fuel waste  

Energy Technology Data Exchange (ETDEWEB)

Atomic Energy of Canada has recently submitted for regulatory and public review an Environmental Impact Statement (EIS) on a concept for disposal of Canada`s nuclear fuel waste. The EIS is supported by nine primary references that summarize major aspects of the concept, including a postclosure environmental and safety assessment. The scope of the postclosure assessment is largely determined by the requirements of the Atomic Energy Control Board (AECB) of Canada. These requirements include a quantitative estimate of the annual effective dose equivalent to an individual in the most exposed group of people (the critical group) for 10,000 years following closure of the disposal facility, and a radiological risk criterion with an associated dose rate limit of 0.05 mSv/a. Over this long time frame, a quantitative assessment cannot be based on actual observations, and thus we use scientific arguments and simulations with ...

1995-12-01

84

Naval Sea Systems Command occupational safety and health record-keeping system. Hazardous Materials Control Module. Program maintenance manual  

Energy Technology Data Exchange (ETDEWEB)

Since August 1984, the MITRE Corporation has been supporting the Naval Sea Systems Command (NAVSEA) and the Naval Medical Command (NAVMEDCOM) in their joint efforts to enhance the Navy Occupational Health Information Management System (NOHIMS). The goal of the enhancement effort was to create a comprehensive occupational health and safety system for Navy industrial facilities by expanding upon the original NOHIMS functions and adding modules for hazard deficiency abatement, hazardous-material control, injury claims and compensation, and safety and health training. To meet this goal, MITRE developed an enhanced industrial subsystem, referred to as the Occupational Safety and Health Record Keeping System (OSHRKS), using a prototyping approach and a public-domain data base-management software package, the Veterans Administration's (VA's) FileManager (FileMan).

1987-06-01

85

Bias in calculated k{sub eff} from subcritical measurements by the {sup 252}Cf-source-driven noise analysis method  

Energy Technology Data Exchange (ETDEWEB)

The development of MCNP-DSP, which allows direct calculation of the measured time and frequency analysis parameters from subcritical measurements using the {sup 252}Cf-source-driven noise analysis method, permits the validation of calculational methods for criticality safety with in-plant subcritical measurements. In addition, a method of obtaining the bias in the calculations, which is essential to the criticality safety specialist, is illustrated using the results of measurements with 17.771-cm-diam, enriched (93.15), unreflected, and unmoderated uranium metal cylinders. For these uranium metal cylinders the bias obtained using MCNP-DSP and ENDF/B-V cross-section data increased with subcriticality. For a critical experiment [height (h) = 12.629 cm], it was {minus}0.0061 {+-} 0.0003. For a 10.16-cm-high cylinder (k {approx} 0.93), it was 0.0060 {+-} 0.0016, and for a subcritical ...

1995-07-01

86

The Joint Convention on the Safety of Spent fuel Management and on the safety of Radioactive Waste Management: A UK Regulator's Perspective  

International Nuclear Information System (INIS)

The UK fully supports the objective of the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management to achieve and maintain a high level of safety worldwide in spent fuel and radioactive waste management, through the enhancement of national measures and international co-operation, including where appropriate, safety-related co-operation. The UK's Health and Safety Executive, through its Nuclear Safety Directorate (NSD), has been committed to the Convention since the initial negotiations to set up the Convention and provided the president of the first review meeting in 2003. It would be wrong of any nation to believe that they have all the best solutions to managing spent fuel and radioactive waste. The process of compiling reports for the Convention review meetings provides a structured process through which every ...

87

Plant life management models with special emphasis to the integration of safety with non-safety related programs  

International Nuclear Information System (INIS)

Due to current social and economical framework, in last years many nuclear power plant owners started a program for the Long Term Operation (LTO)/PLIM (Plant Life Management) of their older nuclear facilities. PLIM/PLEX has already been implemented in many countries (USA, Russia, etc.). This process has many nuclear safety implications, other than strategic and political ones. The need for tailoring the available safety assessment tools to such applications has become urgent in recent years and triggered many research actions. In particular, a PLIM framework requires both a detailed review of the features of the main safety programs (Maintenance, ISI, Surveillance) and a complete integration of these programs into the general management system of the plant. New external factors, such as: large use of subcontractors, need for efficient management of spare parts, request for heavy plant refurbishment ...

2007-10-15

88

Regulatory view of the close-out of the uranium ore mine Zirovski Vrh  

International Nuclear Information System (INIS)

The production of the uranium mine Zirovski Vrh ceased in 1990. The main remaining problem of the remadiation are mine and mill tailings. The uranium mine Zirovski Vrh has one mill tailings site Borst and one waste pile Jazbec. According to the Act on protection against ionising radiation and nuclear safety which was adopted by the Parliament in 2002, they are classified as radiation facilities. Slovenian Nuclear Safety Administration (SNSA) is authorised for issuing a mandatory consent to mining work. The SNSA prepared the initial proposal of content of the safety report for the mine waste pile Jazbec. In 2005, according to the detailed content of this document, the public company Zirovski Vrh Ltd prepared the safety report which was examined by an authorised expert for radiation and nuclear safety. After a careful revision of the safety ...

2005-09-05

89

Regulatory requirements for design of safety related computer based control Systems in Indian PHWRs: case study of DPHS-PCS for TAPP-3 and 4  

International Nuclear Information System (INIS)

Computer based control systems for safety related applications in nuclear power plants have to meet not only the functional, performance and interface requirements, they in addition, have to meet regulatory requirements like enhanced reliability, safety and security and should provide fault tolerance, diagnostics and self-supervision. The control system architecture, hardware design and software design should meet requirements as specified in design code and guides of AERB. The Dual Processor Hot Standby Process Control System (DPHS-PCS) for TAPP-3 and 4 is a safety related (Class- IB) system. DPHS-PCS regulates PHT pressure, Pressuriser pressure, Pressuriser level, Bleed condenser pressure, Bleed condenser level and Steam generator pressure. The performance, reliability and safety requirements of this control system are met by employing a fault tolerant computer configuration developed for this purpose ...

2005-03-01

90

Demonstration drop test and design enhancement of the CANDU spent fuel storage basket in dry storage facility  

British Library Electronic Table of Contents (United Kingdom)

A dry interim storage facility has been constructed at the Wolsung power plant in Korea. This dry storage facility has seven separated modules. There are 40 long slender cylinders in one module. In one cylinder, ten baskets where sixty CANDU spent fuel bundles are loaded are stacked and stored. For this dry storage facility, analyses and tests for hypothetical accident conditions that might occur while moving and storing the baskets into a cylinder were performed. In a demonstration test, one of test basket models did not satisfy one of the safety-related requirements. Thus, the revised basket designs were generated using a structural evaluation based on finite element analyses and specimen tests. Among these revised designs, one design was chosen as a final revised basket design. The fina...

2011-01-01

91

The discovery and development of proteomic safety biomarkers for the detection of drug-induced liver toxicity  

British Library Electronic Table of Contents (United Kingdom)

Biomarkers are biometric measurements that provide critical quantitative information about the biological condition of the animal or individual being tested. In drug safety studies, established toxicity biomarkers are used along with other conventional study data to determine dose-limiting organ toxicity, and to define species sensitivity for new chemical entities intended for possible use as human medicines. A continuing goal of drug safety scientists in the pharmaceutical industry is to discover and develop better trans-species biomarkers that can be used to determine target organ toxicities for preclinical species in short-term studies at dose levels that are some multiple of the intended human dose and again later in full development for monitoring clinical trials at lower therapeutic ...

2010-01-01

92

Participative risk management in the construction of onshore pipelines  

Energy Technology Data Exchange (ETDEWEB)

This paper described a risk control management tool that has been developed by Petrobras Petroleo, the largest Brazilian oil company and one of the world's leading oil companies. The system covers health, safety and environmental (HSE) issues regarding pipeline construction projects. The limitations of traditional safety management systems for coping with the critical problems related to environmental safety issues were discussed. In particular, this paper described how the HSE tool evaluates the risks resulting from the following aspects of onshore pipeline construction and assembly: establishing right-of-way and route locations, transporting pipe, developing the construction site, opening the trench, pipe laying, pipe bending, concrete external coating, welding, external anticorrosive coatings, pipe placement backfilling, hydrostatic testing, maintenance operations, and pipeline ...

2000-07-01

93

Monte Carlo verification of point kinetics for safety analysis of nuclear reactors  

Energy Technology Data Exchange (ETDEWEB)

Monte Carlo neutron transport methods can be used to verify the applicability of point kinetics for safety analysis of nuclear reactors. KENO-NR was used to obtain the transfer function of the Advanced Neutron Source reactor and the time delay between the core power production and the external detectors, a parameter of interest to the safety systems design. The good agreement between the Monte Carlo generated transfer function and the point kinetics transfer function validates that the uncommon ANS geometry does not preclude the use of point kinetics in the frequency range that was investigated. Various features of the power spectral densities also demonstrated the applicability of point kinetics. The time delay was obtained from the cross-power spectral density (CPSD) and is {approximately}15 ms. These analyses show that frequency analysis can be used experimentally to investigate the validity of the use of point kinetics models in ...

1995-06-01

94

Effect of tetracycline hydrochloride treatment on the critical thermal maximum of common shiners  

Energy Technology Data Exchange (ETDEWEB)

The transfer of fish from field to laboratory facilities or their propagation in closed or restricted systems frequently results in bacterial infection and ultimately large-scale mortality. In attemps to alleviate this problem, we have added tetracycline hydrochloride to the water prophylactically (pretreating tanks before wild fish were added) and therapeutically (treating tanks after bacterial outbreaks were detected.) In the present study, we examined the effect of tetracyline hydrochloride on the critical thermal maximum (CTM) of the common shiner (Notropis cornutus).

1980-01-01

95

Safety gas management system utilizing telephone cable  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance for the facilities is ...

1988-02-10

96

Proceedings of national conference on operating experience of nuclear reactors and power plants: book of preprints  

International Nuclear Information System (INIS)

The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)

2006-11-13

97

National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware  

Energy Technology Data Exchange (ETDEWEB)

When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that ...

2001-07-27

98

Sensor test facilities and capabilities at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. It is a facility for evaluating advanced sensor systems for monitoring activities ...

1996-12-31

99

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Topical report No. 6, CSD unit - operation and maintenance, 1983  

Energy Technology Data Exchange (ETDEWEB)

A summary of the 1983 Critical Solvent Deashing unit performance at the Wilsonville Advanced Coal Liquefaction R and D Facility is presented. All periods of on feed operation, unscheduled shutdowns, and scheduled shutdowns are accounted for and tabulated. Causes of unscheduled shutdowns are identified and discussed. Details of repeated, major maintenance problems with various pieces of equipment are presented. Where applicable, solutions are discussed. Historical operations and maintenance data are presented and used for comparison purposes in order to better indicate areas of improvement in the unit. 4 references, 7 figures, 3 tables.

1985-03-01

100

Reactor physics results from fast flux test facility operation  

International Nuclear Information System (INIS)

Criticality was first achieved with the Fast Flux Test Facility (FFTF) a little more than 10 yr ago on February 9, 1980. Although the FFTF was designed and built primarily for testing fuels, materials, and components for the liquid-metal fast breeder reactor program, it has, over its first 10 yr of operation, provided valuable information in many other areas. This paper provides a summary of the contributions to the physics of liquid-metal reactors (LMRs) obtained from operation of and testing in the FFTF, with emphasis on some of the more significant and interesting accomplishments.

1990-11-11

101

Monte Carlo Uncertainty Analyses of Pulsed Activation in the National Ignition Facility Gunite Shielding  

International Nuclear Information System (INIS)

The global effect of activation cross-section uncertainties on calculated radiological quantities is investigated for the first time using a methodology based on Monte Carlo random sampling. The method is applied to the calculation of the uncertainty in the contact dose rate from the gunite shielding of the National Ignition Facility chamber after 30 yr of pulsed irradiation. Some critical cross section contributing significantly to the overall uncertainty are identified. By a reasonable reduction of the uncertainty in those cross sections, the accuracy in the calculated total contact dose rate is greatly improved.

2003-05-01

102

Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C  

Energy Technology Data Exchange (ETDEWEB)

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these ...

2009-11-01

103

Hydrogen flame acceleration and transition to detonation  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.

1984-01-01

104

Hydrogen flame acceleration and transition to detonation  

International Nuclear Information System (INIS)

This paper describes the results obtained from two large experimental facilities built at Sandia National Laboratories in Albuquerque, NM. FLAME (Flame Acceleration Measurements and Experiments) is a large horizontal rectangular channel designed to study flame acceleration, transition to detonation, simulation of combustion in containment geometries, component heating, and other problems in hydrogen combustion relevant to reactor safety. The Heated Detonation Tube has been designed to study detonations in hydrogen-air-steam mixtures. Both facilities have been in operation for just over a year. 12 figures.

1984-10-23

105

Workshop on tritium safety and environmental effects, October 15--17, 1990, Aiken, South Carolina: Session summaries  

Energy Technology Data Exchange (ETDEWEB)

A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.

1991-04-18

106

NRC safety research in support of regulation, FY 1992. Volume 7  

Energy Technology Data Exchange (ETDEWEB)

This report, the eighth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1992. A special emphasis on accomplishments in nuclear power plant aging research reflects recognition that a number of plants are entering the final portion of their original 40-year operating licenses and that, in addition to current aging effects, a focus on safety considerations for license renewal becomes timely. The primary purpose of performing regulatory research is to develop and provide the Commission and its staff with the technical bases for regulatory decisions on the safe operation of licensed nuclear reactors and facilities, to find unknown or unexpected safety problems, and to develop data and related information for the purpose of revising the Commission`s rules, ...

1993-05-01

107

NRC safety research in support of regulation, FY 1992  

Energy Technology Data Exchange (ETDEWEB)

This report, the eighth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1992. A special emphasis on accomplishments in nuclear power plant aging research reflects recognition that a number of plants are entering the final portion of their original 40-year operating licenses and that, in addition to current aging effects, a focus on safety considerations for license renewal becomes timely. The primary purpose of performing regulatory research is to develop and provide the Commission and its staff with the technical bases for regulatory decisions on the safe operation of licensed nuclear reactors and facilities, to find unknown or unexpected safety problems, and to develop data and related information for the purpose of revising the ...

1993-05-01

108

Organization and safety in nuclear power plants  

International Nuclear Information System (INIS)

Perspectives from industry, academe, and the NRC are brought together in this report and used to develop a logical framework that links management and organization factors and safety in nuclear power plant performance. The framework focuses on intermediate outcomes which can be predicted by organizational and management factors, and which are subsequently linked to safety. The intermediate outcomes are efficiency, compliance, quality, and innovation. The organization and management factors can be classified in terms of environment, context, organizational governance, organizational design, and emergent processes. Initial empirical analyses were conducted on a limited set of hypotheses derived from the framework. One set of hypotheses concerned the relationships between one of the intermediate outcome variables, efficiency, as measured by critical hours and outage rate, and safety, as measured by 5 NRC ...

109

Geology and our future: summary of a workshop report  

Energy Technology Data Exchange (ETDEWEB)

This report highlights the significance of the geological sciences to the nation and to society. Discussions include understanding plate tectonics and surface processes, exploring the continental crust, ocean basins and the deep earth, applications of geology to social problems such as mineral resources, waste disposal, siting of critical facilities, geological hazards, water resources management, and coastal zones. The state of health of geological research is also discussed. (ACR)

1983-01-01

110

Thermohydraulic study of a MTR fuel element aimed at the construction of an irradiation facility; Estudo termohidraulico de um elemento combustivel tipo MTR visando a construcao de um dispositivo de irradiacao  

Energy Technology Data Exchange (ETDEWEB)

A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)

1980-07-01

111

Application of probabilistic methods to accident analysis at waste management facilities  

International Nuclear Information System (INIS)

Probabilistic risk assessment is a technique used to systematically analyze complex technical systems, such as nuclear waste management facilities, in order to identify and measure their public health, environmental, and economic risks. Probabilistic techniques have been utilized at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, to evaluate the probability of a catastrophic waste hoist accident. A probability model was developed to represent the hoisting system, and fault trees were constructed to identify potential sequences of events that could result in a hoist accident. Quantification of the fault trees using statistics compiled by the Mine Safety and Health Administration (MSHA) indicated that the annual probability of a catastrophic hoist accident at WIPP is less than one in 60 million. This result allowed classification of a catastrophic hoist accident as ''not credible'' at WIPP per DOE definition. Potential uses of ...

112

Evaluation of light-water-moderated, mixed-oxide, hexagonal pitch lattices  

International Nuclear Information System (INIS)

The use of previously measured mixed-oxide (MOX) fuel systems as benchmarks can be valuable tool in computational analysis and quality assurance efforts. The Fissile Materials Disposition Program (FMDP) has identified these experiments as potential benchmarks, or standards, for VVER's employing MOX fuel. Standards for the analysis of these benchmark experiments were based on those used in the recent compilation International Handbook of Evaluated Criticality Safety Benchmark Experiments begun in 1992 by the U.S. Department of Energy. The Los Alamos National Laboratory's archives were explored for log-book records of these experiments without success. These experiments were the first to use MOX fuel in light water. Three approach-to-critical experiments were performed using fuel rods at various pitches and different plutonium-oxide concentrations. A parallel program verified the prediction of critical ...

1997-11-16

113

Nuclear incident monitor criticality alarm instrument for the Savannah River Site: Technical manual  

Energy Technology Data Exchange (ETDEWEB)

The Savannah River Site is a Department of Energy facility. The facility stores, processes, and works with fissionable material at a number of locations. Technical standards and US Department of Energy orders, require these locations to be monitored by criticality alarm systems under certain circumstances. The Savannah River Site calls such instruments Nuclear Incident Monitors or NIMs. The Sole purpose of the Nuclear Incident Monitor is to provide an immediate evacuation signal in the case of an accidental criticality in order to minimize personnel exposure to radiation. The new unit is the third generation Nuclear Incident Monitor at the Savannah River Site. The second generation unit was developed in 1979. It was designed to eliminate vacuum-tube circuits, and was the first solid state NIM at SRS. The major design objectives of the second generation NIM were to improve reliability and reduce ...

1996-05-21

114

Summary of Initial Testing of SuperLig 644 at the TFL Ion Exchange Facility  

Energy Technology Data Exchange (ETDEWEB)

Research at the Savannah River Technology Center aided development of a technical design basis for a Waste Treatment Plant (WTP) to pre-treat and vitrify Hanford tank waste as part of the River Protection Project (RPP). The research addresses safety concerns, process optimization, and waste form compliance. This program will provide technical data to ensure that the process functions as it was designed and minimizes costs.

2001-04-17

115

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, ...

2002-02-01

116

Development of technical information basis of aging management for nuclear power plants  

International Nuclear Information System (INIS)

In order to implement effective safety regulations on aging management for reactor facilities etc., the information on important technology issues, the latest technical knowledge including evaluation technology, test and research outcomes, related codes and standards, regulation information, operation experiences such as accidents and trouble, etc. with respect to aging-induced deterioration in and outside Japan and in other industries, were collected, organized and evaluated. (author)

2007-08-01

117

Research and development of neutron radiography in IAERU  

Energy Technology Data Exchange (ETDEWEB)

In the Institute for Atomic Energy, Rikkyo University, just after the TRIGA-2 research reactor of 100 kW has attained the criticality, the cylindrical box for neutron radiography (NR) irradiation was made in the attached pool, and the research on NR was started in 1961. Thereafter in 1985, the vertical irradiation pipe was installed in the reactor tank, and the experiment for collecting the basic data was begun. In 1986, based on the obtained data, the NR irradiation facility on full scale was installed in No. 2 tangential horizontal experimental hole. As the main NR irradiation facilities, the vertical neutron irradiation pipe, the use of which is stopped now, the NR facility using the horizontal experimental hole (RUR/N2), the irradiation facility and ancillary facilities such as beam shutter, beam catcher and hoist are described. As the main equipments for ...

1995-03-01

118

OPERATION OF A PUBLIC GEOLOGIC CORE AND SAMPLE REPOSITORY IN HOUSTON TEXAS  

Energy Technology Data Exchange (ETDEWEB)

In the spring of 2002, the Department of Energy provided an initial 1-year grant to the Bureau of Economic Geology (BEG) at The University of Texas at Austin (UT). The grant covered the one-year operational expenses of a worldclass core and cuttings facility located in Houston, Texas, that BP America donated to the BEG. The DOE investment of $300,000, matched by a $75,000 UT contribution, provided critical first-year funds that were heavily leveraged by the BP gift of $7.0 million in facilities and cash. DOE also provided a one-month extension and grant of $30,000 for the month of May 2003. A 5-year plan to grow a permanent endowment in order to manage the facility in perpetuity is well under way and on schedule. The facility, named the Houston Research Center, represents an ideal model for a strong Federal, university, and private partnership to accomplish a national good. This ...

2003-06-01

119

Long-term storage of Greater-Than-Class C Low-Level Waste  

Energy Technology Data Exchange (ETDEWEB)

Under Federal law, the Department of Energy (DOE) is responsible for safe disposal of Greater-Than-Class C Low-Level Waste (GTCC LLW) generated by licenses of the Nuclear Regulatory commission (NRC) or Agreement States. Such waste must be disposed of in a facility licensed by the NRC. It is unlikely that licensed disposal of GTCC LLW will be available prior to the year 2010. Pending availability of disposal capacity, DOE is assessing the need for collective, long-term storage of GTCC LLW. Potential risks to public health and safety caused by long-term storage of GTCC LLW at the place of generation will be evaluated to determine if alternative facilities are warranted. If warranted, several options will be investigated to determine the preferred alternative for long-term storage. These options include modification of an existing DOE facility, development of a new DOE facility, or ...

1990-01-01

120

Rethinking the role of social theory in socio-technical analysis: a critical realist approach to aircraft maintenance  

British Library Electronic Table of Contents (United Kingdom)

Based on empirical research within the aviation industry we have come to some surprising and sometimes counterintuitive conclusions concerning aircraft maintenance that are relevant for the discussion of social theory and its application towards the explanation and management of socio-technical systems. In this article, the human role in the activity of aircraft maintenance is taken as an example to illustrate the need for critical discussions on social theory in order to better understand safety in socio-technical systems This challenges us to consider the theoretical basis related to how we currently approach the human factor in management of such systems. We propose in the article that Roy Bhaskars' book ?The possibility of naturalism?a philosophical critique of the contemporary human s...

2010-01-01

121

Modelling of density limit phenomena in toroidal helical plasmas  

Energy Technology Data Exchange (ETDEWEB)

The physics of density limit phenomena in toroidal helical plasmas based on an analytic point model of toroidal plasmas is discussed. The combined mechanism of the transport and radiation loss of energy is analyzed, and the achievable density is derived. A scaling law of the density limit is discussed. The dependence of the critical density on the heating power, magnetic field, plasma size and safety factor in the case of L-mode energy confinement is explained. The dynamic evolution of the plasma energy and radiation loss is discussed. Assuming a simple model of density evolution, of a sudden loss of density if the temperature becomes lower than critical value, then a limit cycle oscillation is shown to occur. A condition that divides the limit cycle oscillation and the complete radiation collapse is discussed. This model seems to explain the density limit oscillation that has been observed on the W7-AS stellarator. ...

2000-03-01

122

Experimental study of neutron noise with criticality safety applications in mind  

Energy Technology Data Exchange (ETDEWEB)

A study has been conducted on the statistics of detected neutrons that leaked from four subcritical reflected, enriched-uranium assemblies, to explore the feasibility of developing a criticality warning system based on neutron noise analysis. Studies were conducted on three possible discriminators, i.e., three signatures that might be used to discriminate among assemblies of various multiplications. The noise analysis techniques studied performed well enough in deeply subcritical situations to deserve testing in an applications environment. They have a good chance of detecting changes in reactivity that are potentially dangerous. One can expect sharpest results when doing comparisons, i.e., when comparing two records, one taken in the past under circumstances known to be normal and one taken now to search for change.

1985-11-01

123

Dynamic construction of outage lists for safety analysis of power transmission lines. Dynamische Erstellung von Ausfallisten fuer die Sicherheitsanalyse elektrischer Energieuebertragungssysteme  

Energy Technology Data Exchange (ETDEWEB)

An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).

1990-04-23

124

Containment integrated leakage rate test (ILRT) of Indian PHWR  

International Nuclear Information System (INIS)

Integrated Leakage Rate Test (ILRT) of containment system plays a very important role in safety of a Nuclear Power Plant. Containment system constitutes the last physical barrier to release of radioactivity from the core and is called upon to mitigate the consequences of not only accidents within the design basis, but also some of the highly unlikely severe accidents. Hence, leak tightness of containment becomes uttermost priority for the safety of plant personnel and public. The containment and associated ESFs are tested before the first criticality and there after periodically during service. The pre-operational integrated leakage rate is carried out at LOCA based design pressure, at periodic test pressure and at some intermediate pressure points to assess the leakage characteristics. This paper summarizes the various requirements and activities relevant to the ILRT of the Indian Pressurized Heavy Water Reactor (PHWR) ...

2005-12-01

125

Posttest analysis of the FFTF inherent safety tests  

Energy Technology Data Exchange (ETDEWEB)

Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest analyses. The purpose of this paper is to ...

1987-01-01

126

Posttest analysis of the FFTF inherent safety tests  

International Nuclear Information System (INIS)

Inherent safety tests were performed during 1986 in the 400-MW (thermal) Fast Flux Test Facility (FFTF) reactor to demonstrate the effectiveness of an inherent shutdown device called the gas expansion module (GEM). The GEM device provided a strong negative reactivity feedback during loss-of-flow conditions by increasing the neutron leakage as a result of an expanding gas bubble. The best-estimate pretest calculations for these tests were performed using the IANUS plant analysis code (Westinghouse Electric Corporation proprietary code) and the MELT/SIEX3 core analysis code. These two codes were also used to perform the required operational safety analyses for the FFTF reactor and plant. Although it was intended to also use the SASSYS systems (core and plant) analysis code, the calibration of the SASSYS code for FFTF core and plant analysis was not completed in time to perform pretest analyses. The purpose of this paper is to ...

1987-06-07

127

Development of CANDU Void Reactivity Uncertainty Evaluation Methodology  

International Nuclear Information System (INIS)

One of inherent characteristics of CANDU reactor is positive void reactivity in contrast to other pressurized light water reactors. During the large break loss of coolant accident, power pulse will be occurred during short time of early phase of accident due to positive void reactivity. However the duration of this power pulse is short, energy due to power pulse would be accumulated in the cladding material and will affect the peak cladding temperature or number of failed fuel elements. Recently, Canadian Nuclear Safety Commission (CNSC) indicated that the amount of void reactivity might be larger than the assumed values in safety analysis and this indication was based on the experimental data from ZED-2 facility. Based on that, the estimation of uncertainties due to the void reactivity during LBLOCA is the most important issue for CANDU safety analysis. In this study, a framework of uncertainty ...

2010-10-01

128

Design and safety evaluation of radioactive gas handling and storage in the FFTF  

International Nuclear Information System (INIS)

During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain safety aspects of the ...

1976-06-13

129

ARIES-AT safety design and analysis  

Energy Technology Data Exchange (ETDEWEB)

ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under ...

2006-01-15

130

ARIES-AT safety design and analysis  

International Nuclear Information System (INIS)

ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under ...

2006-01-01

131

Verification of safety critical software  

Energy Technology Data Exchange (ETDEWEB)

To assure quality of safety critical software, software should be developed in accordance with software development procedures and rigorous software verification and validation should be performed. Software verification is the formal act of reviewing, testing of checking, and documenting whether software components comply with the specified requirements for a particular stage of the development phase[1]. New software verification methodology was developed and was applied to the Shutdown System No. 1 and 2 (SDS1,2) for Wolsung 2,3 and 4 nuclear power plants by Korea Atomic Energy Research Institute(KAERI) and Atomic Energy of Canada Limited(AECL) in order to satisfy new regulation requirements of Atomic Energy Control Boars(AECB). Software verification methodology applied to SDS1 for Wolsung 2,3 and 4 project will be described in this paper. Some errors were found by this methodology during the software development for SDS1 and were corrected by ...

1996-12-01

132

Verification of safety critical software  

International Nuclear Information System (INIS)

To assure quality of safety critical software, software should be developed in accordance with software development procedures and rigorous software verification and validation should be performed. Software verification is the formal act of reviewing, testing of checking, and documenting whether software components comply with the specified requirements for a particular stage of the development phase[1]. New software verification methodology was developed and was applied to the Shutdown System No. 1 and 2 (SDS1,2) for Wolsung 2,3 and 4 nuclear power plants by Korea Atomic Energy Research Institute(KAERI) and Atomic Energy of Canada Limited(AECL) in order to satisfy new regulation requirements of Atomic Energy Control Boars(AECB). Software verification methodology applied to SDS1 for Wolsung 2,3 and 4 project will be described in this paper. Some errors were found by this methodology during the software development for SDS1 and were corrected by ...

1996-01-01

133

Licensing experiences of safety critical software systems in nuclear applications a case study  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes results of reviews on the safety, critical software performed during the licensing process for the new Wolsung units. Each of these CANDU-type nuclear power plants has two micro-computerized shutdown systems. The SDS No. 1 program is graphically programmed in such a manner that its development process does not essentially differ from the design process of the conventional analog counterpart. This approach is understandable even to a reviewer in the regulatory agency without additional training in software engineering. The confidence in the reliability of this system is strengthened by the reverse verification and increased by extensive testing such as the reliability test. Concerning SDS No. 2, the development process is significantly influenced by the {open_quotes}software cost reduction project{close_quotes} of the U.S. naval research laboratory, and is, as a whole, clear and well structured except for the modules ...

1997-12-01

134

Licensing experiences of safety critical software systems in nuclear applications a case study  

International Nuclear Information System (INIS)

This paper summarizes results of reviews on the safety, critical software performed during the licensing process for the new Wolsung units. Each of these CANDU-type nuclear power plants has two micro-computerized shutdown systems. The SDS No. 1 program is graphically programmed in such a manner that its development process does not essentially differ from the design process of the conventional analog counterpart. This approach is understandable even to a reviewer in the regulatory agency without additional training in software engineering. The confidence in the reliability of this system is strengthened by the reverse verification and increased by extensive testing such as the reliability test. Concerning SDS No. 2, the development process is significantly influenced by the software cost reduction project of the U.S. naval research laboratory, and is, as a whole, clear and well structured except for the modules related to the operation of the ...

1997-06-01

135

Feasibility of subcriticality and NDA measurements for spent fuel by frequency analysis techniques with {sup 252}Cf  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven frequency analysis method can be used for measuring the subcritical neutron multiplication factor of arrays of LWR fuel and as little as a single PWR fuel assembly. These measurements can be used to verify the criticality safety margins of spent LWR fuel configurations and thus could be a means of obtaining the information to justify burnup credit for spent LWR transportation/storage casks. In addition, the data can be used to validate calculational methods for criticality safety. These measurements provide parameters that have a higher sensitivity to changes in fissile mass than neutron multiplication factor and thus serve as a better test of calculational methods. The analysis have also shown that measurement of the cross power spectral density (CPSD) between detectors on one side of a single fuel assembly and an internal or external {sup 252}Cf source driving the fission ...

1996-05-01

136

Automated Critical Peak Pricing Field Tests: Program Descriptionand Results  

Energy Technology Data Exchange (ETDEWEB)

California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that ...

2006-04-06

137

Preliminary investigation of /sup 252/Cf-driven neutron noise analysis for subcritical fuel solution systems  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA ...

1981-01-01

138

D & D screening risk evaluation guidance  

Energy Technology Data Exchange (ETDEWEB)

The Screening Risk Evaluation (SRE) guidance document is a set of guidelines provided for the uniform implementation of SREs performed on decontamination and decommissioning (D&D) facilities. Although this method has been developed for D&D facilities, it can be used for transition (EM-60) facilities as well. The SRE guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the current risk to human health and the environment, exterior to the building, from ongoing or probable releases within a one-year time period. The Worker Exposure Index (WEI) calculates the current risk to workers, occupants and visitors inside contaminated D&D ...

1995-09-01

139

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Science.gov (United States)

The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped springmass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research.

1981-01-01

140

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Science.gov (United States)

The dynamic response characteristics of the vertical axis wind turbine (VAWT) rotor are important factors governing the safety and fatigue life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. The primary tools now in use for rotor analysis are described and discussed. These tools include a lumped spring mass model (VAWTDYN) and also finite-element based approaches. The accuracy and completeness of current capabilities are also discussed.

1981-05-01

141

Assessment of the PIUS physics and thermal-hydraulic experimental data bases  

Energy Technology Data Exchange (ETDEWEB)

The PIUS reactor utilizes simplified, inherent, passive, or other innovative means to accomplish safety functions. Accordingly, the PIUS reactor is subject to the requirements of 10CFR52.47(b)(2)(i)(A). This regulation requires that the applicant adequately demonstrate the performance of each safety feature, interdependent effects among the safety features, and a sufficient data base on the safety features of the design to assess the analytical tools used for safety analysis. Los Alamos has assessed the quality and completeness of the existing and planned data bases used by Asea Brown Boveri to validate its safety analysis codes and other relevant data bases. Only a limited data base of separate effect and integral tests exist at present. This data base is not adequate to fulfill the requirements of 10CFR52.47(b)(2)(i)(A). Asea Brown Boveri has stated that it ...

1993-12-31

142

Work plan for the Isotopes Facilities Deactivation Project at Oak Ridge National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the Isotopes Facilities Deactivation Project (IFDP) is to place former isotopes production facilities at the Oak Ridge National Laboratory in a safe, stable, and environmentally sound condition; suitable for an extended period of minimum surveillance and maintenance (S&M) and as quickly and economical as possible. Implementation and completion of the deactivation project will further reduce the risks to the environment and to public safety and health. Furthermore, completion of the project will result in significant S&M cost savings in future years. The IFDP work plan defines the project schedule, the cost estimate, and the technical approach for the project. A companion document, the IFDP management plan, has been prepared to document the project objectives, define organizational relationships and responsibilities, and outline the management control systems to be employed in the management of the ...

1995-05-01

143

Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro has been assessing and upgrading its facilities and implementing response alternatives to potential damage resulting from a major earthquake. This paper reviews the utility`s seismic evaluation of its overhead transmission system, focusing on the Lower Mainland area where most of the tall critical river-crossing towers are located. The paper gives an overview of the geologic environment of the Lower Mainland and outlines the criteria used for assessing existing structures for their ability to withstand design seismic loads. It then describes the investigation and analysis methods used in the assessment, including geotechnical field tests, ground response analysis, determination of soil liquefaction potential, and dynamic analysis of structures and piles. Options for seismic upgrades are discussed and illustrated by the case of the Pitt River crossing, where tower foundations were reinforced with steel pipe piles.

1995-12-31

144

Low enrichment fuel conversion for Iowa State University. Progress report, August 1, 1991--July 31, 1992  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the UTR-10 reactor at Iowa State University which went critical on low enriched uranium (LEU) fuel on August 14, 1991. However, subsequent to the criticality experiments the fuel plates started to discolor. In addition, roll pins used to lift the fuel assemblies were discovered to be cracked. It was determined that these problems were due to chemical agents in the primary coolant water. The roll pins were replaced by solid stainless steel pins. The primary coolant was replaced and the reactor is currently in operation. Surveillance specimens will be used to monitor any possible future discoloration. The high enriched fuel (HEU) is being prepared for eventual shipment to a high enriched fuel receiving facility.

1992-08-01

145

Low enrichment fuel conversion for Iowa State University  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the UTR-10 reactor at Iowa State University which went critical on low enriched uranium (LEU) fuel on August 14, 1991. However, subsequent to the criticality experiments the fuel plates started to discolor. In addition, roll pins used to lift the fuel assemblies were discovered to be cracked. It was determined that these problems were due to chemical agents in the primary coolant water. The roll pins were replaced by solid stainless steel pins. The primary coolant was replaced and the reactor is currently in operation. Surveillance specimens will be used to monitor any possible future discoloration. The high enriched fuel (HEU) is being prepared for eventual shipment to a high enriched fuel receiving facility.

1992-08-01

146

Evaluation of codisposal viability of MOX (FFTF) DOE-owned fuel: Phase 1 -- Intact mode calculations  

Energy Technology Data Exchange (ETDEWEB)

The authors provide the intact criticality information that supports the disposal of spent nuclear fuel (SNF) from the US Department of Energy's (DOE's) Fast Flux Test Facility (FFTF) in the potential Monitored Geologic Repository at Yucca Mountain. FFTF is one of more than 250 forms of DOE-owned SNF. Because of the variety of the DOE SNF, the National Spent Nuclear Fuel Program has designated nine representative fuel groups for disposal criticality analyses based on fuel matrix, primary fissile isotope, and enrichment. The FFTF fuel is representative of the mixed-oxide fuel (MOX) group.

1999-07-01

147

Thermal hydraulic test for core cooling system using steam generators  

Energy Technology Data Exchange (ETDEWEB)

As a candidate of the new concept safety system for the next generation PWR in Japan, the hybrid safety systems, which are combination of the active and the passive safety systems, and passive core cooling system by natural circulation in the reactor coolant loop with horizontal-type steam generators during Loss of Coolant Accidents (LOCAs) are investigated. The passive safety systems are advanced accumulators (ACC), primary-side and secondary-side automatic-depressurization systems (ADS, SADS), and a gravity-driven safety injection system (GDI). The horizontal steam generator design avoids a siphon break caused from the accumulation of non-condensable gases in the tubes by using a vent line in the channel head of the steam generators. This study investigates the passive core cooling characteristics of horizontal-type steam generators under LOCAs. The integrated thermal-hydraulic ...

1999-07-01

148

The cascad spent fuel dry storage facility  

International Nuclear Information System (INIS)

France has a wide variety of experimental spent fuels different from LWR spent fuel discharged from commercial reactors. Reprocessing such fuels would thus require the development and construction of special facilities. The French Atomic Energy Commission (CEA) has consequently opted for long-term interim storage of these spent fuels over a period of 50 years. Comparative studies of different storage concepts have been conducted on the basis of safety (mainly containment barriers and cooling), economic, modular design and operating flexibility criteria. These studies have shown that dry storage in a concrete vault cooled by natural convection is the best solution. A research and development program including theoretical investigations and mock-up tests confirmed the feasibility of cooling by natural convection and the validity of design rules applied for fuel storage. A facility called CASCAD was built at the CEA's ...

1991-04-14

149

CASCAD dry storage concept for spent fuel  

International Nuclear Information System (INIS)

Further to a cost-benefit analysis of the various medium-term and long-term and H.L.W. storage possibilities, C.E.A. (French Atomic Energy Commission) and S.G.N. decided to develop an original dry storage process with natural convection cooling that offers many advantages: cut in the total investment and operating costs; high operating safety; natural convection cooling; existence of two containment barriers irrespective of the assumed clad conditions; flexible, modular and compact design. The process was first implemented in the so-called CASCAD Cadarache Facility (vault-type facility) constructed in Cadarache mainly to store fuel from Brennilis heavy water reactor. For the purpose, a large program was set up to develop and validate computer codes, in particular with the use of mockups. On the request of many clients, and owing to the outstanding operating results of the CASCAD Cadarache Facility, SGN ...

1994-08-01

150

The U.S. Liquid Metal Reactor Development Program  

International Nuclear Information System (INIS)

This paper discusses how the U.S. Liquid Metal Reactor Development Program has been restructured to carry out R and D on advanced reactor technology. The program gives particular emphasis to improvements to reactor safety. The new directions are based on the technology of the integral fast reactor (IFR). Much of the basis for superior safety performance using IFR technology has been experimentally verified and aggressive programs continue in EBR-II and TREAT. Progress has been made in demonstrating both the metallic fuel and the new electrochemical processes of the IFR. The FFTF facility is converting to metallic fuel; however, FFTF also maintains a considerable U.S. program in oxide fuels. In addition, generic programs are continuing in steam generator testing, materials development, and with international cooperation, aqueous reprocessing.

1988-05-01

151

Safety considerations in the application of tension leg platforms and spar based systems  

Energy Technology Data Exchange (ETDEWEB)

This paper is focused on TLP and Spar technology as applied to floating production applications. In particular, safety considerations as related to classification and certification requirements are addressed. This covers hull structures, marine systems, production facilities and the relevant mooring systems for each platform type from design approval on through construction, installation and ultimately the ongoing maintenance of the platform to acceptable standards throughout its operating life. The experience of the American Bureau of Shipping with these platforms will be utilized in supporting the practical application of classification and regulatory standards to ensure safe operations and concluding that use of such standards in conjunction with an experienced classification society provides a substantial benefit to companies utilizing these technologies. (author)

1998-07-01

152

Results of the 1986 FFTF inherent safety tests  

International Nuclear Information System (INIS)

A series of tests was recently completed at the 400-MW (thermal) Fast Flux Test Facility (FFTF) to further demonstrate the passive safety characteristics of liquid-metal-cooled fast reactors. Earlier FFTF testing of decay heat removal by sodium natural circulation was reported in 1981. The main purpose of the 1986 test series was to demonstrate passive reactor shutdown during a loss-of-flow event when several inherent shutdown devices called gas expansion modules (GEMs) were installed in the reactor. However, these tests also provide further data on the natural circulation performance of the primary system, in particular the reactor core, and thus add to the data base available for checking the validity of available analytical tools.

1987-06-07

153

FFTF criteria for run-to-cladding-breach experiments  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled fast reactor, which is designed to test a variety of different structural and fuel materials. A safety analysis is performed for each experiment that is irradiated in FFTF. The FFTF final safety analysis report (FSAR) assumed that all driver fuel assemblies would maintain cladding integrity during normal operations and all design transients. Maintenance of cladding integrity retains three barriers to any fission gas release to the public and also prevents any potential contact between the fuel and coolant. Experiments are, in general, expected to meet the same criterion. Selected experiments can, however, be classified as run-to-cladding-breach experiments (RTCB). The purpose of this paper is to describe alternative acceptance criteria for RTCB experiments that they feel provide protection equivalent to the maintenance of cladding integrity.

1986-06-15

154

Environmental control for machine shops  

Energy Technology Data Exchange (ETDEWEB)

Metal machining facilities pose interesting design problems. This article provides an overview of key environmental control considerations and ways to deal with them. Machine shops offer a variety of environmental control challenges to mechanical engineers. Among the design problems that must be considered include: whether to provide space heating only or year-round air conditioning; temperature and relative humidity requirements; air cleanliness; exhaust air requirements; the type of HVAC system to be used; industrial waste and plumbing considerations; compressed air needs; and noise control. In addition, the designer must comply with worker health and safety and environmental protection regulations set forth by the National Institute of Safety and Health (NIOSH), OSHA, and EPA, as well as with any applicable state and local requirements.

1994-04-01

155

Application of probabilistic methods to validate NPP pipewhip impact simulations  

British Library Electronic Table of Contents (United Kingdom)

Piping in nuclear power plants is vital to the proper operation and safety of these facilities. To assure safety in the unlikely event of a pipe break, it is necessary to evaluate the consequences from the resulting whipping pipe on neighboring components and structures. Numerical simulations allow for rapid evaluation of these consequences. Before simulations can be accepted, however, the methodology and computer codes must be validated against experimental results. This paper uses a probabilistic approach to validate pipe whip simulations against limited experimental results. Probabilistic analysis software was developed and coupled to existing deterministic finite element software. An example of a whipping pipe impacting against a reinforced concrete slab was simulated. The described pr...

2006-01-01

156

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in establishing regulatory ...

2001-01-15

157

New intelligent monitor for CANDU type NPP  

International Nuclear Information System (INIS)

Nuclear energy provides a third of Europe's electricity with nearly no greenhouse-gas emissions. Sustained efforts are now being conducted to harmonize regulations all over Europe through WENRA and to converge on technical nuclear safety practices within the TSO network ETSON (European Technical Safety Organizations Network). In CANDU type NPP the tritiated water occurs by the neutron bombardment of deuterium. The tritiated water vapors imply health hazard (in the critical organs of the body the water presents a 10 day average biological half-life) and the early detection in nuclear plants of tritium emissions is important because the tritiated water vapors have the same characteristics as of atmospheric water vapors. By detecting tritiated vapors, the monitoring system ensures the following objectives: (a) indicates levels of tritium generally due to heavy water leakage, (b) reduces the possibility of health hazard. In ...

2009-10-12

158

Flux enhancement options for an LEU-fueled MIT reactor  

International Nuclear Information System (INIS)

The Monte-Carlo transport code MCNP was used to evaluate possible arrangements of cores for the MIT Reactor using monolithic LEU fuel. Plate and moderator thicknesses were varied, and fixed absorbers and inner reflectors added in an effort to maximize available neutron fluxes at in-core and ex-core locations of experimental facilities. Addition of D_2O in the H_2O moderator was also evaluated. Comparisons of the fast, epithermal, and thermal fluxes were made at selected locations. Keff was also evaluated and critical blade heights compared with the existing HEU core. Results indicate that the LEU fluxes could approach HEU values with the use of a fueled in-core experimental facility, a fixed boron absorber spider and an inner beryllium reflector. (author)

2004-11-07

159

Characterization of Filter Elements for Service in a Coal Gasification Environment  

Energy Technology Data Exchange (ETDEWEB)

The Power Systems Development Facility (PSDF) is a joint Department of Energy/Industry sponsored engineering-scale facility for testing advanced coal-based power generation technologies. High temperature, high pressure gas cleaning is critical to many of these advanced technologies. Barrier filter elements that can operate continuously for nearly 9000 hours are required for a successful gas cleaning system for use in commercial power generation. Since late 1999, the Kellogg Brown & Root Transport reactor at the PSDF has been operated in gasification mode. This paper describes the test results for filter elements operating in the Siemens-Westinghouse particle collection device (PCD) with the Transport reactor in gasification mode. Operating conditions in the PCD have varied during gasification operation as described elsewhere in these proceedings (Martin et al, 2002).

2002-09-19

160

Analysis of deteriorating processes in primary circuit facilities and determination of their priorities and relevance to the lifetime of the main primary circuit components  

International Nuclear Information System (INIS)

The major degradation mechanisms acting during the aging of selected WWER-440/213 primary circuit facilities were assessed critically. The analysis gave evidence that such mechanisms include radiation and fatigue damage of the reactor pressure vessel (effect of the neutron flow, cyclic fatigue promoted by the corrosive medium, effect of thermal aging), corrosion-mechanical and thermo-mechanical (fatigue) damage of the steam generator (stress corrosion cracking, erosion corrosion, thermal aging, wear), thermal and dynamic aging of the pressurizer, and corrosion-mechanical damage of the primary circuit piping (thermal aging, corrosion). (J.B.). 5 tabs., 1 fig., 62 refs.

161

Operational procedures - industry observations and opportunities for improvement  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to relate some of the commonly encountered problems with operational procedures in the nuclear industry and offer practical suggestions for their elimination. The paper is based on recent consultant experience in assisting industry clients with human performance related design and assessment initiatives. Operational procedures are a key part of an integrated system design. Procedures provide the specified instructions for actions people are to undertake in operating a facility to achieve production and safety goals. While organizations continue to make substantial investments in procedure development and maintenance, problems with procedures continue to occur, as evidenced through operating inefficiencies, errors, and events. The paper reviews the role procedures play in facility operations, comments on current development and maintenance practices, discusses the extent of human performance ...

2003-07-01

162

Learning and case-based reasoning for faults diagnosis-aiding in nuclear power plants  

International Nuclear Information System (INIS)

The aim of this thesis is the design of a faults diagnosis-aiding system in a nuclear facility of the Cea. Actually the existing system allows the optimization of the production processes in regular operating conditions. Meanwhile during accidental events, the alarms, managed by threshold, are bringing no relevant information. To increase the reliability and the safety, the human operator needs a faults diagnosis-aiding system. The developed system, SECAPI, combines problem solving techniques and automatic learning techniques, that allow the diagnosis and the the simulation of various faults happening on nuclear facilities. Its reasoning principle uses case-based and rules-based techniques. SECAPI owns a learning module which reads out knowledge connected with faults. It can then simulate various faults, using the inductive logical computing. SECAPI has been applied on a radioactive tritium treatment operating channel, at ...

1998-01-01

163

Indexes to Nuclear Regulatory Commission issuances, July--December 1996. Volume 44, Index 2  

Energy Technology Data Exchange (ETDEWEB)

Digests and indexes for issuances of the Commission (CLI), the Atomic Safety and Licensing Board Panel (LBP), the Administrative Law Judges (ALJ), the Directors` Decisions (DD), and the Decision on Petitions for Rulemaking (DPRM) are presented in this document. These digests and indexes are intended to serve as a guide to the issuances. Information elements common to the cases heard and ruled upon are: case name (owner(s) of facility); full text reference (volume and pagination); issuance number; issues raised by apellants; legal citations (cases, regulations, and statutes); name of facility, docket number; subject matter of issues and/or rulings; type of hearing (operating license, operating license amendment, etc.); type of issuance (memorandum, order, decision, etc.).

1997-04-01

164

Five years operating experience at the Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.

1987-04-01

165

Five years operating experience at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.

1987-09-13

166

Final Environmental Impact Statement to construct and operate a facility to receive, store, and dispose of 11e.(2) byproduct material near Clive, Utah (Docket No. 40-8989)  

Energy Technology Data Exchange (ETDEWEB)

A Final Environmental Impact Statement (FEIS) related to the licensing of Envirocare of Utah, Inc.`s proposed disposal facility in Tooele county, Utah (Docket No. 40-8989) for byproduct material as defined in Section 11e.(2) of the Atomic Energy Act, as amended, has been prepared by the Office of Nuclear Material Safety and Safeguards. This statement describes and evaluates the purpose of and need for the proposed action, the alternatives considered, and the environmental consequences of the proposed action. The NRC has concluded that the proposed action evaluated under the National Environmental Policy Act of 1969 (NEPA) and 10 CFR Part 51, is to permit the applicant to proceed with the project as described in this Statement.

1993-08-01

167

Comparison of FFTF (Fast Flux Test Facility) feedback reactivities with SASSYS calculations in a loss-of-flow-without-scram event  

International Nuclear Information System (INIS)

The Cycle 8A static tests conducted in the Fast Flux Test Facility (FFTF) during 1986 have resulted in the separation of various feedback reactivity components. These feedback components, described by closed-form equations depending only on the reactor temperature field, can be regarded as database for the validation and/or calibration of feedback mechanistic models. The SASSYS safety analysis code contains the most developed feedback reactivity models and was selected for the comparison study between database and mechanistic calculations for the FFTF. Although detailed feedback models for control rod repositioning and core radial expansion/bowing exist, only the simple models were available in SASSYS at the time of this study. The results are described in this paper.

1988-05-01

168

The 0.9 MW proton beam at PSI and studies on a 10 MW cyclotron  

Energy Technology Data Exchange (ETDEWEB)

The conceptual design for a cyclotron that could possibly deliver a 10 MW proton beam, presented at the previous ADTT conference, is discussed in comparison with the operational experience gained with 0.9 MW beam power in the upgraded cyclotron facility at PSI that has reached the design goal of 1.5 mA at 590 MeV in 1995. Some critical aspects of the design are e.g. RF power and beam loading, beam loss and activation, space charge effects and bunching. 12 refs., 2 figs., 1 tab.

1997-09-01

169

Progress and Plans for R&D and the Conceptual Design of the ILC Main Linacs  

CERN Document Server

The International Linear Collider Main Linacs are based on superconducting accelerator structures operating at 1.3 GHz. The basis for this design has been developed and tested at DESY and R&D is progressing at many laboratories around the world including DESY, Orsay, KEK, FNAL, SLAC, Cornell, and JLAB. The status of the TESLA-style cavities and rf system will be reviewed and parameters for the ILC linac will be described. The role of the different linac test facilities will discussed and the critical items and R&D program to support a Conceptual Design and Technical Design will be outlined.

2005-01-01

170

Evolution of reactivity control mechanisms for nuclear research and power reactors in India  

International Nuclear Information System (INIS)

Division of Remote Handling and Robotics (DRHR) at Bhabha Atomic Research Centre (BARC) has been working on design and development of Reactivity Control Mechanisms for Nuclear Research Reactors (Dhruva, KAMINI and recently Critical Facility of Advanced Heavy Water Reactor (AHWR)) as well as Power Reactors in India (Pressurized Heavy Water Reactors of 220 MWe at Narora and recently India's first 540 MWe PHWR Unit -1 and 2 at Tarapur). This paper gives a brief account of evolution of reactivity control mechanisms for nuclear research and power reactors in India. (author)

2009-10-01

171

Annual Report 2007. Nuclear Regulatory Authority  

International Nuclear Information System (INIS)

The present Annual Report of Activities of the Nuclear Regulatory Authority (ARN), prepared regularly from the creation as independent institution, describes across tree parts and seven annexes the activities developed by the organism during 2007. The main topic are: the organization and the activity of the ARN; the regulatory standards; the licensing and inspection of nuclear power plants and critical facilities; the emergency systems; the occupational surveillance; the environmental monitoring; improved organizational. Also, this publication have annexes with the following content: regulatory documents; inspections to medical, industrial and training installations; regulatory guides; measurement and evaluation of the drinking water of Ezeiza.

2004-07-11

172

Tiger Team assessment of the Brookhaven National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of the Department of Energy's (DOE's) Tiger Team Assessment conducted at Brookhaven National Laboratory (BNL) in Upton, New York, between March 26 and April 27, 1990. The BNL is a multiprogram laboratory operated by the Associated Universities, Inc., (AUI) for DOE. The purpose of the assessment was to provide the status of environment, safety, and health (ES H) programs at the laboratory. The scope of the assessment included a review of management systems and operating procedures and records; observations of facility operations; and interviews at the facilities. Subteams in four areas performed the review: ES H, Occupational Safety and Health, and Management and Organization. The assessment was comprehensive, covering all areas of ES H activities and waste management operations. Compliance with applicable Federal, State, and local regulations; ...

1990-06-01

173

HISTORICAL AMERICAN ENGINEERING RECORD - IDAHO NATIONAL ENGINEERING AND ENVIRONMENTAL LABORATORY, TEST AREA NORTH, HAER NO. ID-33-E  

Energy Technology Data Exchange (ETDEWEB)

Test Area North (TAN) was a site of the Aircraft Nuclear Propulsion (ANP) Project of the U.S. Air Force and the Atomic Energy Commission. Its Cold War mission was to develop a turbojet bomber propelled by nuclear power. The project was part of an arms race. Test activities took place in five areas at TAN. The Assembly & Maintenance area was a shop and hot cell complex. Nuclear tests ran at the Initial Engine Test area. Low-power test reactors operated at a third cluster. The fourth area was for Administration. A Flight Engine Test facility (hangar) was built to house the anticipated nuclear-powered aircraft. Experiments between 1955-1961 proved that a nuclear reactor could power a jet engine, but President John F. Kennedy canceled the project in March 1961. ANP facilities were adapted for new reactor projects, the most important of which were Loss of Fluid Tests (LOFT), part of an international safety program for ...

2005-02-01

174

Data report of BWR post-CHF tests. Transient core thermal-hydraulic test program. Contract research  

Energy Technology Data Exchange (ETDEWEB)

JAERI has been performing transient core thermal-hydraulic test program. In the program, authors performed BWR/ABWR DBE simulation tests with a test facility, which can simulate BWR/ABWR transients. The test facility has a 4 x 4 bundle core simulator with 15-rod heaters and one non-heated rod. Through the tests, authors quantified the thermal safety margin for core cooling. In order to quantify the thermal safety margin, authors collected experimental data on post-CHF. The data are essential for the evaluation of clad temperature transient when core heat-up occurs during DBEs. In comparison with previous post-CHF tests, present experiments were performed in much wider experimental condition, covering high clad temperature, low to high pressure and low to high mass flux. Further, data at wider elevation (lower to higher elevation of core) were obtained in the present experiments, which make possible to ...

2001-03-01

175

The AECL's research reactor analysis methodology  

International Nuclear Information System (INIS)

As the cost of developing completely new computer codes becomes prohibitive, designers of nuclear facilities are turning to more cost-effective approaches for meeting increasingly strict regulatory requirements applied to safety-related analysis. For designing and licensing the MAPLE family of research reactors, Atomic Energy of Canada Ltd. (AECL) is employing the strategy of adapting major existing codes by linking them together within networks of custom-built interface software. This approach builds on the international investment in developing, maintaining, and verifying existing primary codes and focuses on the less onerous development of interface codes. The resultant code systems are then validated for the new applications of interest.

176

Hazardous waste operational plan for site 300  

Energy Technology Data Exchange (ETDEWEB)

This plan outlines the procedures and operations used at LLNL's Site 300 for the management of the hazardous waste generated. This waste consists primarily of depleted uranium (a by-product of U-235 enrichment), beryllium, small quantities of analytical chemicals, industrial type waste such as solvents, cleaning acids, photographic chemicals, etc., and explosives. This plan details the operations generating this waste, the proper handling of this material and the procedures used to treat or dispose of the hazardous waste. A considerable amount of information found in this plan was extracted from the Site 300 Safety and Operational Manual written by Site 300 Facility personnel and the Hazards Control Department.

1982-02-12

177

Atomic power of Germany and ecology  

International Nuclear Information System (INIS)

The NPPs safety system in Germany is discussed. It is shown that there exists no threat for the German NPPs at the peace times. They release insignificant quantities of radioactive substances into the water and atmosphere. The average equivalent dose constitutes 0.0005 mSv annually. The annual equivalent dose for the personnel is equal to 4.4 mSv. At the same time, the NPPs contribute to a certain degree to the environmental medium improvement, preventing the ingress therein of the sulfur and carbon dioxide, dust and nitrogen oxides by application of fossil fuels. Attention is also paid to reprocessing facilities and also to the nuclear fuel wastes disposal. The advantages of the nuclear power engineering in comparison with the fossil fuel power engineering are enumerated

178

Application of the GEM shutdown device to the FFTF reactor  

Energy Technology Data Exchange (ETDEWEB)

A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.

1986-01-01

179

Application of the GEM shutdown device to the FFTF reactor  

International Nuclear Information System (INIS)

A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.

1986-11-16

180

A conceptual model for laboratory ventilation greenhouse gas planning  

British Library Electronic Table of Contents (United Kingdom)

There is increasing pressure to operate laboratory facilities in environmentally and financially sustainable ways. A key factor in achieving this goal is careful consideration of how energy is used by the buildings' ventilation system, both for conditioning air supplied to the laboratories and the energy used moving air through the building. Traditionally, laboratory energy use is treated as an engineering concern within the scope of the building's overall design and operation. However, this approach limits the involvement of key stakeholders in many important decisions and can lead to unexpected safety concerns for the laboratory's users. We believe that a broad view of the parties affected by a laboratory building's operations is necessary to avoid having the various stakeholders working...

2011-01-01

181

Numerical study on the heat transfer to CO_2 flowing upward in a heated vertical tube at supercritical pressure  

International Nuclear Information System (INIS)

Full text of publication follows: As the coolant experiences no phase change in the core, SCWRs, unlike LWRs, cannot use design criteria based on the critical heat flux concept. The commonly accepted practice in SCWRs is to specify cladding temperature limits that must be met during transient and accident events. Therefore for the design of the SCWR, it is very important to predict the heat transfer coefficient to the supercritical water coolant with great accuracy. Our recent study focuses on the critical issue of measuring heat transfer to supercritical water at prototypical SCWR conditions and to develop the tools to predict the SCWR thermal behavior. A heat transfer test loop using a surrogate fluids, CO_2, is under construction. The reason of using CO_2 instead of water is that (i) valuable insight of the physical phenomena can be obtained with this fluid, and (ii) some existing facilities already used surrogate ...

2005-10-02

182

Evaluation of critical heat flux of tight lattice core with subchannel analysis code NASCA  

International Nuclear Information System (INIS)

Reduced-Moderation Water reactor (RMWR) is a light water breeder reactor developed by Japan Atomic Energy Research Institute (JAERI). The RMWR comprises tight lattice fuel assemblies with gap clearance of around 1.0 mm to reduce water volume ratio to achieve a high conversion ratio. It is important to estimate the thermal hydraulic safety margin of the tight lattice core of the RMWR. In the present study, the boiling transition (BT) prediction performance of the subchannel analysis code NASCA developed for the current BWR cores was assessed for series of tight lattice critical heat flux (CHF) experiments performed in JAERI. The test section was a 7-rod bundle with rod diameter of 12.3 mm, rod gap of 1.0 mm and heated length of 1.8m. Axial power distribution was flat. With a simple subchannel model, the code overestimates the critical power in the high mass velocity region, although the predicted ...

2003-04-20

183

Safety and Environmental Aspects of Inertial Fusion Energy: An Overview of Recent Activities and Developments in the United States  

International Nuclear Information System (INIS)

During the past 2 yr, significant progress has been made in several areas related to the safety and environmental (S and E) aspects of inertial fusion energy (IFE). An updated methodology has been developed, and accident analyses have been performed for two IFE conceptual power plants and a target fabrication facility. Parallel to the consequence analyses of different accident scenarios, ongoing studies of accident initiating events are being used to support safety assessment and create a basic framework of types of events to consider in future risk characterization of new plant designs. Target designers/fabrication specialists have been provided with ranking information related to the S and E characteristics of candidate target materials. We have revisited waste management options for IFE, introducing the concept of clearance versus the traditional shallow land burial. A brief summary of results in each of these activities ...

2003-05-01

184

Key Performance Criteria Affecting the Most the Safety of a Nuclear Waste Long Term Storage : A Case Study Commissioned by CEA  

Energy Technology Data Exchange (ETDEWEB)

As part of the work scope set in the French law on high level long lived waste R&D passed in 1991, CEA is conducting a research program to establish the scientific basis and assess the feasibility of long term storage as an option for the safe management of nuclear waste for periods as long as centuries. This goal is a significant departure from the current industrial practice where storage facilities are usually built to last only a few decades. From a technical viewpoint such an extension in time seems feasible provided care and maintenance is exercised. Considering such long periods of time, the risk for Society of loosing oversight and control of such a facility is real, which triggers the question of whether and how long term storage safety can be actually achieved. Therefore CEA commissioned a study (1) in which MUTADIS Consultants (2) and CEPN (3) were both involved. The case study looks into several past and ...

2003-02-24

185

The Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama  

Science.gov (United States)

The investigation of various Two-Stage Liquefaction (TSL) process configurations was conducted at the Wilsonville Advanced Coal Liquefaction R D Facility between July 1982 and September 1986. The facility combines three process units. There are the liquefaction unit, either thermal (TLU) or catalytic, for the dissolution of coal, the Critical Solvent Deashing unit (CSD) for the separation of ash and undissolved coal, and a catalytic hydrogenation unit (HTR) for product upgrading and recycle process solvent replenishment. The various TSL process configurations were created by changing the process sequence of these three units and by recycling hydrotreated solvents between the units. This report presents a description of the TSL configurations investigated and an analysis of the operating and performance data from the period of study. Illinois No. 6 Burning Star Mine coal Wyodak Clovis Point Mine coal were processed. ...

1990-05-01

186

One-piece removal of JRR-3 reactor block  

Energy Technology Data Exchange (ETDEWEB)

JRR-3 is a research reactor of 10 MWt output, which attained the criticality in 1962. All the design, manufacture, installation and others of this reactor were carried out by Japanese technologies, except the fuel and heavy water as the moderator and coolant, therefore it is nicknamed Home-made No.1 Reactor. Recently, due to the change in the state of utilizing research reactors and the rise of quality in the utilization, JRR-3 has become to be unable to meet sufficiently the needs of users. The plan of reconstructing the JRR-3 was considered under such situation, and in order to reuse the reactor building, the reactor proper is removed, and an entirely new, high performance, versatile reactor is to be constructed. In this paper, as to the removal works of the JRR-3 reactor proper, the method of execution, design, the execution of works and so on are outlined. The removal works of the reactor facilities were started in February, 1986. The ...

1987-07-01

187

Large eddy simulation based fire modeling applications for Indian nuclear power plant  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: The Nuclear Power Plants (NPPs) are always designed for the highest level of safety against postulated accidents which may be initiated due to internal or external causes. One of the external/internal causes, which may lead to accident in the reactor and its associated systems, is fire in certain vital areas of the plant. Conventionally, the fire containment approach and/or the fire confinement approach is used in designing the fire protection systems of NPPs. Indian NPPs (PHWRs) follow the combined approach to ensure plant safety and all newly designed plants are required to comply with the provisions of Atomic Energy Regulatory Board (AERB) fire safety Guide. In respect of older plants, the reassessment of adequacy of fire safety provisions in the light of current advances has becomes essential so as to decide upon the steps for retrofitting. Keeping this in mind the ...

2005-07-01

188

Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5  

Energy Technology Data Exchange (ETDEWEB)

Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE`s Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography ...

1994-01-01

189

Development of the Decontamination Approach for the West Valley Demonstration Project Decontamination Project Plan  

Energy Technology Data Exchange (ETDEWEB)

This paper details the development of a decontamination approach for the West Valley Demonstration Project (WVDP), Decontamination Project Plan (Plan). The WVDP is operated by West Valley Nuclear Services Company (WVNSCO), a subsidiary of Westinghouse Government and Environmental Services, and its parent companies Washington Group International and British Nuclear Fuels Limited (BNFL). The WVDP is a waste management effort being conducted by the United States Department of Energy (DOE) at the site of the only commercial nuclear fuel reprocessing facility to have operated in the United States. This facility is part of the Western New York Nuclear Service Center (WNYNSC), which is owned by the New York State Energy Research and Development Authority (NYSERDA). As authorized by Congress in 1980 through the West Valley Demonstration Project Act (WVDP Act, Public Law 96-368), the DOE's primary mission at the WVDP is to solidify high-level ...

2002-02-25

190

Preliminary safety evaluation of a commercial-scale krypton-85 encapsulation facility  

International Nuclear Information System (INIS)

This paper demonstrates that a commercial-scale facility for encapsulating krypton-85 in zeolite-5A or glass at a 2000 MTHM per year nuclear fuel reprocessing plant can be designed to contain fragments and the 340 to 850 kCi krypton-85 inventory from an assumed catastrophic failure of the high pressure vessel. The vessel failure was assumed as a worst case and was not based on a detailed design evaluation or operating experience. The process design is based on existing commercial hot isostatic pressing technology operated at up to 40 times the scale required for krypton encapsulation. From the calculated process gas inventory in the pressure vessel and vessel design, the maximum explosive energy of 8.4 kg TNT and resulting vessel plug and fragment velocities were calculated. The facility Containment Cell housing the high pressure vessel was designed to contain the gases, fragments, and the shock wave energy calculated for a hypothetical vessel ...

1984-08-13

191

FY05-FY06 Advanced Simulation and Computing Implementation Plan, Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The Stockpile Stewardship Program (SSP) is a single, highly integrated technical program for maintaining the safety and reliability of the U.S. nuclear stockpile. The SSP uses past nuclear test data along with future non-nuclear test data, computational modeling and simulation, and experimental facilities to advance understanding of nuclear weapons. It includes stockpile surveillance, experimental research, development and engineering programs, and an appropriately scaled production capability to support stockpile requirements. This integrated national program will require the continued use of current facilities and programs along with new experimental facilities and computational enhancements to support these programs. The Advanced Simulation and Computing program (ASC) is a cornerstone of the SSP, providing simulation capabilities and computational resources to support the annual stockpile assessment ...

2004-07-19

192

Experiments with the HORUS-II test facility  

Energy Technology Data Exchange (ETDEWEB)

Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as ...

1997-12-31

193

Study on core cooling of hybrid safety system for next-generation PWR during LOCA  

International Nuclear Information System (INIS)

Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of noncondensable gas is presented. The integral thermal-hydraulic tests ...

1995-04-23

194

WHO wants more use of irradiated food, calls for education programs  

International Nuclear Information System (INIS)

Short note. The World Health Organization (WHO) has taken aim at critics of irradiated food, claiming that the process has the potential to reduce the incidence of foodborne diseases such as salmonellosis, to cut postharvest food losses and to provide a wider variety of foods for consumers. 'The unwarranted rejection of this process, often based on lack of understanding of what food irradiation entails, may hamper its use in those countries which may benefit most', Dr. Jean-Paul Jardel, WHO's assistant director-general, argued following a recent international conference on the subject. Critics, including Canadians, has opposed food irradiation for years, claiming that more needs to be known about its effects. WHO said the 'vast majority' of the 54 national delegations at the conference supported use of the technology on foods ranging from grain and potatoes to poultry, tropical fruit and strawberries. WHO wants governments to educate the public ...

1989-02-01

195

Development of a Simple Scheme for Prediction of Flame Acceleration and DDT  

International Nuclear Information System (INIS)

Hydrogen combustion phenomenology during severe accidents in nuclear power plants has been a safety issue. Especially, flame acceleration (FA) and Deflagration-to-Detonation Transition (DDT) are important because of their possible destructive impact on the containment or plant systems in it. Accordingly, it is the design goal to avoid FA and DDT for the hydrogen mitigation system. As a result from extensive effort dedicated to resolve the hydrogen issue, compiled information on the FA and DDT has been provided by the NEA. The FA criterion was suggested in terms of the mixture expansion ratio ? , and the criterion for onset of DDT was based on the greatness of the geometrical size of the reactive system compared with the detonation cell width ? of the average mixture composition. The DDT onset criterion reflects the current state of knowledge based on the experimental database; however, the criterion is not sufficient but a necessary condition. Therefore, it should ...

2010-10-01

196

Anticipated climate change impacts on flood characteristics : Moisie River application  

International Nuclear Information System (INIS)

The issue of global warming was discussed with particular reference to the changes that may occur in the hydrological regime within the coming decades in response to predicted changes in climate. Flood events for the 2050 time horizon were investigated along with the consequences on water management and dam safety. Dams operated by Hydro-Quebec are used for flood control, water supply, recreational activities and hydroelectricity. As such, the electric utility relies on methods to evaluate the adaptability of current management plans to climate change. This paper presented the results of a study conducted at the Moisie River watershed, located in northern Quebec. The HSAMI hydrologic model was used to evaluate and compare the occurrences where stream flows and water levels exceed critical values in order to assess the effectiveness of management plans in both current and climate change scenarios. The study considered two different approaches on ...

197

Structural aging program to assess the adequacy of critical concrete components in nuclear power plants  

International Nuclear Information System (INIS)

The Structural Aging (SAG) Program is carried out by the Oak Ridge National Laboratory (ORNL) under sponsorship of the United States Nuclear Regulatory Commission (USNRC). The Program has evolved from preliminary studies conducted to evaluate the long-term environmental challenges to light-water reactor safety-related concrete civil structures. An important conclusion of these studies was that a damage methodology, which can provide a quantitative measure of a concrete structure's durability with respect to potential future requirements, needs to be developed. Under the SAG Program, this issue is being addressed through: establishment of a structural materials information center, evaluation of structural component assessment and repair technologies, and development of a quantitative methodology for structural aging determinations. Progress to date of each of these activities is presented as well as future plans. 7 refs., 5 figs.

1989-08-14

198

Status of safety-related FFTF neutronics parameters  

International Nuclear Information System (INIS)

Quantitative, experimentally based assessments of the biases of the methods used to develop the neutronics design of the FTR are presented together with brief descriptions of the design methods. Uncertainties in biases have been established that are sufficiently small to allow a high degree of confidence in the nuclear design. Experimental data for these assessments have been developed in full-scale zero-power mockups of the final design of the reactor, except for Doppler data from SEFOR. Temperature, power coefficient, and stability methods evaluations are necessarily deferred to acceptance testing during initial startup of the FTR. Sodium voiding and small sample worths continue to be the technical areas of greatest complexity with least experiment-theory correlation. Critical mass, Doppler effects, control rod worth, and spatial power distribution have generally good experiment-theory correlations.

1976-10-01

199

Managing natural resources for sustainable development. Special report  

Energy Technology Data Exchange (ETDEWEB)

The report presents an overview of A.I.D. efforts, which encompass a wide range of environmental issues and support environmental training, research, and institutional development. The report's opening section details A.I.D.'s efforts to enlist host-country support for environmental programs, with specific emphasis on improving natural resource management (especially in Africa), encouraging policy change, strengthening the private sector's environmental role, and preparing environmental profiles of host countries and helping them develop conservation strategies. The ensuing sections recount A.I.D. efforts in particular topics of environmental concern (biological diversity and environmental health and safety), critical ecological areas (coastal areas and forests and fragile lands), and specific country programs (reforestation in Haiti). A brief history of the evolution of the Agency's environmental strategy ...

1987-01-01

200

Inherent Boron Dilution Safety Issue in the French Pressurized Water Reactor: CFD Approach  

International Nuclear Information System (INIS)

Inherent boron dilution can occur in case of a Small Break LOCA when low borated water is mainly accumulated in the U-legs due to reflux boiling in the Steam Generator tubes after the loss of natural circulation. The restart of the natural circulation may lead to criticality because of the injection of these low borated slugs towards the core. To evaluate this potential risk, the boron concentration at the core inlet has to be known which makes necessary to estimate the mixing phenomena in the cold leg, in the downcomer and in the lower plenum: CFD calculations are required. First of all the validation of CFX5 CFD code on the relevant phenomena of inherent boron dilution has been established (UPTF TRAM C3 test). Then, an application to the 900 MW French Pressurized Water Reactor series has been performed. (authors)

2006-07-17

201

Implantation of a essential diesel generator CN Vandellos II and fifth emergency diesel generator Asco  

International Nuclear Information System (INIS)

This article describes the project for the installation of an additional emergency diesel generator in both Asco and Vandellos NPPs. The basic objectives of this project are to improve the availability of the emergency generation system, in order to provide greater ability to address potential contingencies, and also to increase the flexibility of the preventive periodic maintenance of the emergency diesel generators. This maintenance, that is currently a milestone of the critical path of the refueling outage, will be performed on-line. The new diesel generator will be sized to support all the loads considered in the safety case and also the consumption of its own auxiliary systems, and will be tested for operability assessment on the same periodical basis than the existing ones. The solution adopted will also permit that the N diesel generator may be connected to any bus bar class 1E in a station black-out scenario. (Author)

202

FY2000 Annual Self-Evaluation Report for the Pacific Northwest National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

This self-evaluation report offers a summary of results from FY2000 actions to achieve Pacific Northwest National Laboratory's strategy and provides an analysis of the state of their self-assessment process. The result of their integrated planning and assessment process identifies Laboratory strengths and opportunities for improvement. Critical elements of that process are included in this report; namely, a high-level summary of external oversight activities, progress against Operations Improvement Initiatives, and a summary of Laboratory strengths and areas for improvement developed by management from across the laboratory. Some key areas targeted for improvement in FY2001 are: systems approach to resource management; information protection; integrated safety management flow-down to the benchtop; cost management; integrated assessment; Price Anderson Amendments Act (PAAA) Program; and travel risk mitigation.

2000-11-15

203

Emerging trends in information and communication technology in mine safety and disaster management  

British Library Electronic Table of Contents (United Kingdom)

There is tremendous growth in the use of Geographic Information Systems (GIS), Global Positioning Systems (GPS), Remote Sensing, Satellite Communication, and Modeling & Simulation techniques. These tools and techniques helps significantly in characterizing infrastructure, risk area and disaster zones, planning and implementation of hazards reduction measures etc. Communication satellites becomes vital for providing emergency communication and timely relief measures. Integration of space technology inputs into natural disaster monitoring and mitigation mechanisms is critical for hazard reduction. This paper mainly focused on all the issues described above. Major emphasis had been given to the recent developments in information & communication technology enabled tools and their applications ...

2010-01-01

204

ECCS integrated test in TAPP-3 and 4  

International Nuclear Information System (INIS)

Emergency Core Cooling System (ECCS) is a safety critical system provided to mitigate the consequence of Loss of Coolant Accident (LOCA) in PHWR. Unlike 220MWe, all header injection has been introduced in 540MWe to simplify the logic. ECCS Integrated Test is schematic approach to establish that ECC system will behave as per design intent during actual LOCA condition. Objective of ECCS Integrated test is to ascertain that various ECC system components operate as intended in design. Additionally, the various system resistances which form the input to LOCA analysis are validated. This test has been carried out by creating actual LOCA during cold and pressurised condition of PHT system to establish all phases of injection with overlap. This paper discusses the results obtained during the Integrated Test and comparison with the prediction during the commissioning of first unit of 540 MWe. (author)

2006-11-13

205

Dynamic analysis of Darrieus vertical axis wind turbine rotors  

Energy Technology Data Exchange (ETDEWEB)

The dynamic response characteristics of the VAWT rotor are important factors governing the safety and fatique life of VAWT systems. The principal problems are the determination of critical rotor speeds (resonances) and the assessment of forced vibration response amplitudes. The solution to these problems is complicated by centrifugal and Coriolis effects which can have substantial influence on rotor resonant frequencies and mode shapes. This paper will describe and discuss the primary tools now in use at Sandia National Laboratories for rotor analysis. These tools include a lumped spring-mass model (VAWTDYN) and also finite-element based approaches. The discussion will center on the accuracy and completeness of current capabilities and plans for future research. As this paper is meant primarily to provide an overview, much of the detail is omitted and will be presented in a follow-on report.

1981-05-01

206

Class 1E digital systems studies  

International Nuclear Information System (INIS)

This document is furnished as part of the effort to develop NRC Class 1E Digital Computer Systems Guidelines which is Task 8 of USAF Rome Laboratories Contract F30602-89-D-0100. The report addresses four major topics, namely, computer programming languages, software design and development, software testing and fault tolerance and fault avoidance. The topics are intended as stepping stones leading to a Draft Regulatory Guide document. As part of this task a small scale survey of software fault avoidance and fault tolerance practices was conducted among vendors of nuclear safety related systems and among agencies that develop software for other applications demanding very high reliability. The findings of the present report are in part based on the survey and in part on review of software literature relating to nuclear and other critical installations, as well as on the authors' experience in these areas.

207

CFX code application to the French reactor for inherent boron dilution safety issue  

International Nuclear Information System (INIS)

Inherent boron dilution can occur in case of a small Break LOCA when low borated water is accumulated in the U-legs due to reflux boiling in the Steam Generator tubes after the loss of natural circulation. The restart of the natural circulation may lead to criticality because of the injection of these low borated slugs towards the core. To evaluate this potential risk, the boron concentration at the core inlet has to be known which makes necessary to estimate the mixing phenomena in the cold leg, in the downcomer and in the lower plenum: CFD calculations are required. First of all the validation of CFX5 CFD code on the relevant phenomena of inherent boron dilution has been established (UPTF TRAM C3 test). Then, an application to the 900 MW French Pressurized Water Reactor series has been performed. (authors)

2006-09-05

208

Application of hazard analysis - Critical control point (HACCP) principles to primary production: What is feasible and desirable?  

British Library Electronic Table of Contents (United Kingdom)

We show that the HACCP system is not fully applicable at the primary production level, and that food safety is obtained through the careful implementation of good hygiene practice (GHP) at the farm. Guides to GHP intended at primary productions cover one activity, such as cattle rearing or corn production. Yet most farms have more than one activity. Hazards from one activity can be transferred to another activity, and in general this is not considered in one-activity guides. There is a need therefore for farmers to be able to detect and control such transfers. We suggest a horizontal complement to the Guides to GHP that would consider only the application of the Step 6 and Principle 1 of the HACCP system amended as follows: ''List all potential hazards transferred from one activity to anot...

2011-01-01

209

Ageing and life-time management in nuclear power stations - concept and examples; Alterungs- und Lebensdauermanagement in Kernkraftwerken - Konzept und Beispiele  

Energy Technology Data Exchange (ETDEWEB)

Knowledge, assessment and understanding of phenomena caused by ageing, together with systematic utilization and extension of the technical life-time of components and systems, are of critical importance to the safety and economy of electricity generation in nuclear power stations. Economic use can be optimized by integrated ageing and life-time management; it can also be used to improve performance characteristics. (orig.) [Deutsch] Fuer die Sicherheit und Wirtschaftlichkeit der Stromerzeugung in Kernkraftwerken sind die Kenntnis, Bewertung und Beherrschung alterungsbedingter Phaenomene und systematische Ausnutzung bzw. Verlaengerung der technischen Lebensdauer der Komponenten und Systeme von zentraler Bedeutung. Durch ganzheitliches Alterungs- und Lebensdauermanagement, das auch auf die Verbesserung von Leistungsmerkmalen abzielt, kann der wirtschaftliche Nutzen optimiert werden. (orig.)

1999-07-01

210

Accelerated aging speeds test of instrument reliability  

International Nuclear Information System (INIS)

This paper shows how molecular theory paves the way for accelerated aging tests of safety-related equipment in nuclear power plants, as required by NRC qualification programs. Arrhenius' model, based on an equation, provides useful information regarding the extent of molecular change as a function of time and temperature. Critical to determining the aging characteristics and qualified life of organic materials is the activation energy concept, which is derived from information gathered when the molecular reaction of the material is documented over the entire life cycle. In accelerated-aging applications, the importance of the model lies in characterizing the chemical related reactions of materials. The problem with the Arrhenius approach is that, in generating a testing period of reasonable duration, a rather high test temperature must be selected which may lead to an added and unrelated environmental effect.

1982-01-01

211

/sup 252/Cf-source-driven neutron noise measurements of subcriticality for a slab tank containing aqueous Pu-U nitrate  

Energy Technology Data Exchange (ETDEWEB)

In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.

1987-08-01

212

Methodology for calculating guideline concentrations for safety shot sites  

Energy Technology Data Exchange (ETDEWEB)

Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is ...

1997-06-01

213
214

Experience in complying with quality assurance requirements for cask lifting devices  

International Nuclear Information System (INIS)

The Nuclear Assurance Corporation (NAC) owns and operates four NAC-1 truck casks. These casks are used to ship spent reactor fuel assemblies and radioactive reactor-core components. The casks have been loaded or unloaded at a total of fifteen nuclear facilities in the United States. In addition, NAC has used another large, overweight-truck cask to ship radioactive reactor core components from a reactor to a waste burial site. There are many individual differences in the cask handling facilities at each of the reactor stations, nuclear research facilities and the storage and burial sites serviced. Various types of auxiliary lifting and handling devices for on-site cask operations have been required. The quality assurance requirements for the equipment used in interfacing casks with nuclear power plant facilities have become more stringent. This paper presents details on the type of special equipment ...

215

Nuclear research institutes in NEA countries  

Energy Technology Data Exchange (ETDEWEB)

The paper is based on a NEA study entitled `Past Trends and Current State of Nuclear Research Institutes`, which has been published in 1996. The evolution of nuclear research institutes (NRIs) in NEA countries is described from their establishment in the early fifties to present. The objectives, missions, purposes, and competences of NRIs are highlighted. Further, the resources (budget, qualified manpower, equipment such as research reactors and laboratories) are analysed, emphasising the role of the government. Country specific examples are given to illustrate different aspects of the historic evolution, present status and trends of NRIs. It is expected that the future role of NRIs will reflect the progress in nuclear science and technology and the evolving requirements of the nuclear industry with regard to safety enhancement, fuel cycle optimisation, plant life time management and extension, decommissioning of nuclear facilities and ...

1996-12-31

216

Nuclear research institutes in NEA countries  

International Nuclear Information System (INIS)

The paper is based on a NEA study entitled 'Past Trends and Current State of Nuclear Research Institutes', which has been published in 1996. The evolution of nuclear research institutes (NRIs) in NEA countries is described from their establishment in the early fifties to present. The objectives, missions, purposes, and competences of NRIs are highlighted. Further, the resources (budget, qualified manpower, equipment such as research reactors and laboratories) are analysed, emphasising the role of the government. Country specific examples are given to illustrate different aspects of the historic evolution, present status and trends of NRIs. It is expected that the future role of NRIs will reflect the progress in nuclear science and technology and the evolving requirements of the nuclear industry with regard to safety enhancement, fuel cycle optimisation, plant life time management and extension, decommissioning of nuclear facilities and ...

1996-06-04

217

Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and ...

2007-08-01

218

Challenges in environmental radiological surveillance around nuclear facilities  

International Nuclear Information System (INIS)

To accomplish the environmental radiological surveillance need of India's ambitious nuclear power programme, Health Physics Division is infusing new technologies and improved analytical techniques for day to day measurements of various radionuclides in different environmental matrices. It is essential to have techniques for measuring the concentration of radionuclides just above the background level since the discharges from the nuclear facilities are very low i.e. in the range of 5-10% of the prescribed discharge limits by the regulatory bodies. In view of developing ultra-sensitive techniques, the aim of ongoing programmes of the division is to meet the challenges of measuring ultra trace level of radioactivity by adopting state of art new instrumentation and improved sample processing techniques. This will allow us to measure the lowest level of radioactivity (3H, 90Sr, 137Cs, 239+240Pu, etc.) in the environment and thereby estimating the lowest doses to the ...

2007-06-05

219

{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins  

Energy Technology Data Exchange (ETDEWEB)

Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray ...

1996-08-01

220

Laboratory directed research and development program, FY 1996  

Energy Technology Data Exchange (ETDEWEB)

The Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab) Laboratory Directed Research and Development Program FY 1996 report is compiled from annual reports submitted by principal investigators following the close of the fiscal year. This report describes the projects supported and summarizes their accomplishments. It constitutes a part of the Laboratory Directed Research and Development (LDRD) program planning and documentation process that includes an annual planning cycle, projection selection, implementation, and review. The Berkeley Lab LDRD program is a critical tool for directing the Laboratory`s forefront scientific research capabilities toward vital, excellent, and emerging scientific challenges. The program provides the resources for Berkeley Lab scientists to make rapid and significant contributions to critical national science and technology problems. The LDRD program also advances the Laboratory`s core competencies, ...

1997-02-01

221

Safe operation of research reactors and critical assemblies code of practice and annexes  

CERN Document Server

Safe operation of research reactors and critical assemblies

1984-01-01

222

Savannah River Site production reactor safety analysis report. K production reactor  

International Nuclear Information System (INIS)

Nuclear facilities of the Department of Energy (DOE) located at the Savannah River Site must comply with DOE orders as implemented at DOE-SR. The DOE orders cover safety criteria, design criteria, environmental protection, occupational health and safety. The program applies to DOE and contractors. In this section, the Nuclear Regulatory Commission (NRC) criteria and industry codes and standards are addressed as well as DOE orders. Specific DOE orders which add additional criteria have also been noted. A program for assessing and implementing contractor applicable DOE orders has been established. This program ensures that compliance is achieved through developing and implementing policies, programs, and procedures. The primary emphasis is placed on safe, efficient reactor restart and operation. DOE has classified orders applicable to restart as Level I, Category I while those applicable to post-restart are classified as ...

223

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

Energy Technology Data Exchange (ETDEWEB)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

224

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

International Nuclear Information System (INIS)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

225

Radiological safety aspects associated with the handling, storage and disposal of self power neutron detectors in TAPS - 3 and 4  

International Nuclear Information System (INIS)

At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in lead shielding inside spent fuel storage ...

2006-11-13

226

Radiation factors specifying safety in reactor compartments handling in the process of decommissioning nuclear-powered submarines  

International Nuclear Information System (INIS)

The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and structures; (3) ...

1996-03-10

227

Monitoring processes and measuring the effectiveness of the management system  

International Nuclear Information System (INIS)

This document presents the way which the 8th principle of the quality management system 'Process approach' is applied, the principle that is identified and used by international standard ISO 9000. In order to understand the evolution of the management system requirements, as used today in different activities namely, industry, services, and nuclear activities, the authors present an evolution of the quality concept and its traceability to different standards, applicable in time. There are described the requirements of ISO 9001 standard, that represents the most widely spread model for modern organization management and the IAEA concerns related to integration of the above standard requirements into the most recent safety IAEA standard 'The Management System for facilities and activities'. The IAEA Safety Standard GS-R-3 describes a management model considering both the evolution of the quality requirements into the modern ...

2009-10-12

228

Fuzzy multi-objective decision making on a low and intermediate level waste repository safety assessment  

Energy Technology Data Exchange (ETDEWEB)

Low and intermediate waste disposal facilities safety assessment is comprised of several steps from site selection , construction and operation to post-closure performance assessment. This is a multidisciplinary and complex task , and can not be analyzed by one expert only. This high complexity can lead to ambiguity and vagueness in information and consequently in the decision making process. In order to make the decision process clear and objective, there is the need to provide the decision makers with a clear and comprehensive picture of the whole process and, at the same time, simple and easily understandable by the public. This paper suggests the development of an inference system based on fuzzy decision making methodology. Fuzzy logic tools are specially suited to deal with ambiguous data by using language expressions. This process would be capable of integrating knowledge from various fields of environmental sciences. It has an advantage ...

2002-07-01

229

Feasibility study on production of Co-60 in PHWR  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to analyze the safeties and the economics for Co-60 production from Wolsung PHWR and to verify the feasibility on the manufacturing of the final Co-60 source for industrial irradiation. The feasibility of reactor conversion was carried out with KEPCO collaboration. Through the site survey on the experience of Gentililly-2 in Canada, a feasibility of plant conversion, changes in design, equipment and tools for Co-60 production was verified. It was estimated that the reactor conversion would not impose adverse impact on plant safety. For the encapsulation of radiation source and storage of the final products, a modification of concrete hot cell at KAERI was primary concerns. The installation and improvement of facilities are needed to avoid cross contamination and extra radiation exposure. Main items for these are pressure gauge, separated HEPA filter the ceiling separation, extra-shielding and ...

2000-05-01

230

Effectiveness of storage practices in mitigating aging degradation during reactor layup  

Energy Technology Data Exchange (ETDEWEB)

One of the issues identified in the US Nuclear Regulatory Commission`s Nuclear Plant Aging Research program plan is the need to understand the state of ``mothballed`` or other out-of-service equipment to ensure subsequent safe operation. Programs for proper storage and preservation of materials and components are required by NRC regulations (10 CFR 50, Appendix B). However, materials and components have been seriously degraded due to improper storage, protection, or layup, at facilities under construction as well as those with operating licenses. Pacific Northwest Laboratory has evaluated management of aging for unstarted or mothballed nuclear power plants. The investigations revealed that no uniform guidance in the industry addresses reactor layup. In each case investigated, layup was not initiated in a timely manner, primarily because of schedule uncertainty. Hence, it is reasonable to assume that this delay resulted in accelerated aging of some ...

1995-09-01

231

Development of `health and environmental safety assessment network system (HESANS)`  

Energy Technology Data Exchange (ETDEWEB)

With the recent advance of the utilization of nuclear energy in a large scale, social interest is being focussed in the potential risk which the nuclear technology will accompany. Especially after the accidents in Chernobyl and other nuclear facilities, serious anxiety to the utilization of nuclear energy is prevailing among the general public. In order to meet the anxiety and distrust of the population in the use of the nuclear power, the health effect or risk which radioactive materials released into the environment will bring about should be comprehensively and properly evaluated, and then should be widely reported to the population. The development of HESANS code system (Health and Environmental Safety Assessment Network System) was planned to set up such a comprehensive computer code that covers a whole pathway of radioactive material from its release to estimates of derived health effects in the population, including the countermeasures ...

1994-03-01

232

Application of probabilistic methods to validate NPP pipewhip impact simulations  

Energy Technology Data Exchange (ETDEWEB)

Piping in nuclear power plants is vital to the proper operation and safety of these facilities. To assure safety in the unlikely event of a pipe break, it is necessary to evaluate the consequences from the resulting whipping pipe on neighboring components and structures. Numerical simulations allow for rapid evaluation of these consequences. Before simulations can be accepted, however, the methodology and computer codes must be validated against experimental results. This paper uses a probabilistic approach to validate pipe whip simulations against limited experimental results. Probabilistic analysis software was developed and coupled to existing deterministic finite element software. An example of a whipping pipe impacting against a reinforced concrete slab was simulated. The described probabilistic approach was used to validate the numerical simulations. The conclusions obtained were that the numerical simulations of ...

2006-02-15

233

Cold source moderator vessel development for the High Flux Isotope Reactor: Thermal-hydraulic studies  

Energy Technology Data Exchange (ETDEWEB)

A project is underway at Oak Ridge National Laboratory (ORNL) to design, test, and install a cold neutron source facility in the High Flux Isotope Reactor (HFIR). This new cold source employs supercritical hydrogen at cryogenic temperatures both as the medium for neutron moderation and as the working fluid for removal of internally-generated nuclear heating. The competing design goals of minimizing moderator vessel mass and providing adequate structural integrity for the vessel motivated the requirement of detailed multidimensional thermal-hydraulic analyses of the moderator vessel as a critical design subtask. This paper provides a summary review of the HFIR cold source moderator vessel design and a description of the thermal-hydraulic studies that were carried out to support the vessel development.

1998-07-01

234

Cleaning up DOE`s weapons sites: Issues of organization and management  

Energy Technology Data Exchange (ETDEWEB)

Many Department of Energy facilities across the United States are seriously contaminated with radioactive and other hazardous wastes. Decades of focus on weapons production and inadequate attention to long-term solutions for dealing with those wastes have resulted in tremendous problems. The Department of Energy recognizes the seriousness of those problems and is addressing them. In some cases existing management systems are being used to accomplish the new mission of environmental cleanup, and in other cases new systems have been created to help carry out that mission. Widespread criticism of those efforts to data are evidence that the management systems being used may not be appropriate for the job. In particular, it appears that some management systems aren`t producing desired results because they are not well aligned with the people and tasks for whom they are intended, and these issues are discussed in this report.

1994-04-01

235

White Rose oilfield development application. CD-ROM ed.  

Energy Technology Data Exchange (ETDEWEB)

Located approximately 350 km east of Newfoundland, on the eastern edge of the Jeanne d'Arc Basin, and approximately 50 km from both the Terra Nova and Hibernia oilfields, the White Rose oilfield is considered the main oil producing basin off the eastern coast of North America. Husky Oil is very active in the region and holds almost 32 per cent net working interest in the Significant Discovery License areas in the Jeanne d'Arc basin. The development of an economically significant oil discovery in the White Rose Significant Discovery Area is being proposed jointly by Husky Oil and Petro-Canada. It is estimated that the project would enable the recovery of an estimated 36 million cubic meters (230 million barrels) of recoverable oil in this area that covers approximately 40 square kilometers. The operators propose to use a ship-shaped floating production, storage and offloading (FPSO) facility which could store up to 135,000 cubic meters (850,000 ...

2001-01-01

236

Verification and testing of the RTOS for safety-critical embedded systems  

Energy Technology Data Exchange (ETDEWEB)

Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model and the generated code, the other is to find errors in the ...

2003-07-01

237

Verification and testing of the RTOS for safety-critical embedded systems  

International Nuclear Information System (INIS)

Development in Instrumentation and Control (I and C) technology provides more convenience and better performance, thus, adopted in many fields. To adopt newly developed technology, nuclear industry requires rigorous V and V procedure and tests to assure reliable operation. Adoption of digital system requires verification and testing of the OS for licensing. Commercial real-time operating system (RTOS) is targeted to apply to various, unpredictable needs, which makes it difficult to verify. For this reason, simple, application-oriented realtime OS is developed for the nuclear application. In this work, we show how to verify the developed RTOS at each development lifecycle. Commercial formal tool is used in specification and verification of the system. Based on the developed model, software in C language is automatically generated. Tests are performed for two purposes; one is to identify consistency between the verified model and the generated code, the other is to find errors in the ...

2003-05-29

238

Wetlands - A valuable resource for the '90s  

Energy Technology Data Exchange (ETDEWEB)

The nation's wetlands are a valuable resource serving many important natural, industrial, commercial and recreational functions. Wetlands protect shore areas from waves and storms; act as storage areas for flood waters; remove waste from water by trapping soils or silt which settle to the bottom; improve water quality and reduce pollution; are a commercial breeding ground for fish and other foods; and provide space for recreation and habitat for wildlife. They also are located in prime industrial development areas. Recent wetlands losses have caused much public outcry, politicking and regulatory efforts to prevent this trend. During the '90s, the public will see efforts to strike a proper balance regarding wetlands use. Today, wetlands protection is a permitting issue for nearly every major industrial or commercial development and expansion project. Wetlands permit requirements affect a range of business entities. Any project that involves building new ...

1993-04-15

239

FFTF operations: initial operator training simulator program  

International Nuclear Information System (INIS)

This paper describes the Fast Flux Test Facility (FFTF) Operations initial training program utilizing the Operator Training Simulator (OTS). The OTS is a computer-driven system that provides real time response of essential FFTF plant functions to a control room mockup. The FFTF, a 400 Megawatt, three-loop, sodium-cooled fast test reactor will test fuels, materials and equipment for the U.S. Liquid Metal Fast Breeder Reactor Program. Construction is expected to be completed in August 1978. Initial criticality is expected in early 1979. This schedule will require FFTF control room operators to be fully qualified to operate the facility by late 1979. Because FFTF is like no other U.S. nuclear reactor, existing U.S. utility plants could not be depended on to provide highly experienced people to operate FFTF. Therefore, an Operator Training Simulator has been built. The OTS will play a vital role in the formal operator ...

240

Verification of the CFD code FLUENT by post test calculation of ROCOM experiments  

International Nuclear Information System (INIS)

Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV ...

2005-10-02

241

Transuranic material recovery in the Integral Fast Reactor fuel cycle demonstration  

Energy Technology Data Exchange (ETDEWEB)

The Integral Fast Reactor is an innovative liquid metal reactor concept that is being developed by Argonne National Laboratory. It takes advantage of the properties of metallic fuel and liquid metal cooling to offer significant improvements in reactor safety, operation, fuel cycle economics, environmental protection, and safeguards. The plans for demonstrating the IFR fuel cycle, including its waste processing options, by processing irradiated fuel from the Experimental Breeder Reactor-II fuel in its associated Fuel Cycle Facility have been developed for the first refining series. This series has been designed to provide the data needed for the further development of the IFR program. An important piece of the data needed is the recovery of TRU material during the reprocessing and waste operations.

1993-01-01

242

Transuranic material recovery in the Integral Fast Reactor fuel cycle demonstration  

Energy Technology Data Exchange (ETDEWEB)

The Integral Fast Reactor is an innovative liquid metal reactor concept that is being developed by Argonne National Laboratory. It takes advantage of the properties of metallic fuel and liquid metal cooling to offer significant improvements in reactor safety, operation, fuel cycle economics, environmental protection, and safeguards. The plans for demonstrating the IFR fuel cycle, including its waste processing options, by processing irradiated fuel from the Experimental Breeder Reactor-II fuel in its associated Fuel Cycle Facility have been developed for the first refining series. This series has been designed to provide the data needed for the further development of the IFR program. An important piece of the data needed is the recovery of TRU material during the reprocessing and waste operations.

1993-03-01

243

Tools and methods for implementing the control systems on the Mirror Fusion Test Facility  

Energy Technology Data Exchange (ETDEWEB)

Installation of the major hardware subsystems for MFTF is nearing completion. These subsystems include the Fusion Chamber System, the eighty KV Neutral Beam System, the Superconducting Magnet System, and the Personnel Safety System. The Local Controls group has undertaken a uniform aproach to implementing the control systems for all of these hardware subsystems. This approach has two major aspects: (1) to provide a stand-alone computer control system with a remote, portable terminal so that computer control can be provided at the site of the hardware for initial testing, (2) to provide hardware simulators so that the complicated MFTF computer control system can be tested independent of the hardware. The software and hardware tools which were developed to carry out this plan will be described. Our experiences with bringing up subsystems containing up to 900 separate channels of control and status will also be described.

1981-09-29

244

The uses of system integration. In the field of tension between building safety and automation; Nutzen der Systemintegration. Im Spannungsfeld von Gebaeudesicherheit und Gebaeudeautomation  

Energy Technology Data Exchange (ETDEWEB)

There are no 'intelligent' buildings but only 'intelligently controlled' buildings. Intelligent control requires communication between technical facilities, which in turn requires building automation and system integration. [German] Es gibt keine ''intelligenten'', sondern nur ''intelligent betriebene'' Gebaeude. Mit dieser Feststellung ist die Vorbedingung festgelegt, dass Gebaeude ein gewerkeuebergreifendes System benoetigen, das die Komponenten miteinander kommunizieren laesst. Dafuer eignet sich die Gebaeudeautomation. Damit diese ihre Aufgaben erfuellen kann, bedarf es der Systemintegration. (orig.)

2001-07-01

245

Science and Technology Review March 2001  

Energy Technology Data Exchange (ETDEWEB)

This issue contains the following articles: (1) ''Safety and Security Are Enhanced by Understanding Plutonium''. (2) ''Inside the Superblock'' This area of Lawrence Livermore is home to one of just two US plutonium research and development facilities for defense. (3) ''Exploring the Fundamental Limits of Simulations'' Some of the nation's leading computer simulation experts gathered at Lawrence Livermore to discuss the common barriers facing their craft. (4) ''Plutonium Up Close...Way Close'' An examination of stockpile plutonium at the atomic level indicates so far, so good. (5) ''Shocked and Stressed, Metals Get Stronger'' Laser peening yields stronger, corrosion-resistant metals.

2001-03-01

246

Safety analysis of FFTF loss of flow without scram tests  

International Nuclear Information System (INIS)

A program of tests were conducted in July 1986 at the Fast Flux Test Facility (FFTF) to demonstrate that the reactor could withstand a prototypic loss of flow (LOF) without scram without sustaining fuel damage. The reactor was taken to powers up to 50%, and the main primary coolant pump motors were tripped without scramming the control rods. This paper summarizes the analyses performed to demonstrate the maintenance of redundant protection for all design events as well as potential new events introduced by the test. The analyses focused on the following consequences: (1) unexpected test behavior; (2) transient overpower event during the test; and (3) LOF event during the test.

1987-06-07

247

SP-100 fuel pin performance: Results from irradiation testing  

Energy Technology Data Exchange (ETDEWEB)

A total of 86 experimental fuel pins with various fuel, liner, and cladding candidate materials have been irradiated in the Experimental Breeder Reactor-II (EBR-II) and the Fast Flux Test Facility (FFTF) reactor as part of the SP-100 fuel pin irradiation testing program. Postirradiation examination results from these fuel pin are key in establishing performance correlations and demonstrating the lifetime and safety of the reactor fuel system. This paper provides a brief description of the in-reactor fuel pin tests and presents the most recent irradiation data on the performance of wrought rhenium (Re) liner material and high density UN fuel at goal burnup of 6 atom percent (at. %). It also provides an overview of the significant variety of other fuel/liner/cladding combinations which were irradiated as part of this program and which may be of interest to more advanced efforts.

1993-09-01

248

Reliability data update method for emergency diesel generator of Daya Bay Nuclear Power Plant  

British Library Electronic Table of Contents (United Kingdom)

In the field of Living Probabilistic Safety Assessment (LPSA) the reliability data updating is an important factor. In risk analysis equipment failure data is needed to estimate the frequencies of events contributing to risk posed by a facility. Five years data of emergency diesel generator (EDG) of Daya Bay Nuclear Power Plant (NPP) has been studied in this paper. The data updating process has been done by using two methods, i.e., the classical method and Bayesian method. The aim of using these methods is to calculate the operational failure rate (@l) and demand failure probability (p). The results show that the operational failure rate is 1.7E-3 per hour and the demand failure probability is 2.4E-2 demand per day for Daya Bay NPP. By comparing the results obtain from classical and Bayesi...

2011-01-01

249

Radioactive waste management in the USSR: A review of unclassified sources. Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The Soviet Union does not currently have an overall radioactive waste management program or national laws that define objectives, procedures, and standards, although such a law is being developed, according to the Soviets. Occupational health and safety does not appear to receive major attention as it does in Western nations. In addition, construction practices that would be considered marginal in Western facilities show up in Soviet nuclear power and waste management operations. The issues involved with radioactive waste management and environmental restoration are being investigated at several large Soviet institutes; however, there is little apparent interdisciplinary integration between them, or interaction with the USSR Academy of Sciences. It is expected that a consensus on technical solutions will be achieved, but it may be slow in coming, especially for final disposal of high-level radioactive wastes and environmental restoration of ...

1991-03-01

250

Radioactive waste management in the USSR: A review of unclassified sources  

Energy Technology Data Exchange (ETDEWEB)

The Soviet Union does not currently have an overall radioactive waste management program or national laws that define objectives, procedures, and standards, although such a law is being developed, according to the Soviets. Occupational health and safety does not appear to receive major attention as it does in Western nations. In addition, construction practices that would be considered marginal in Western facilities show up in Soviet nuclear power and waste management operations. The issues involved with radioactive waste management and environmental restoration are being investigated at several large Soviet institutes; however, there is little apparent interdisciplinary integration between them, or interaction with the USSR Academy of Sciences. It is expected that a consensus on technical solutions will be achieved, but it may be slow in coming, especially for final disposal of high-level radioactive wastes and environmental restoration of ...

1991-03-01

251

Quality engineering programme in the design process. A major utility 's experience  

International Nuclear Information System (INIS)

The paper describes the latest approach to quality engineering in the design process as applied by Ontario Hydro throughout the various phases of the project life cycle for Ontario Hydro generating stations and related facilities. Ontario Hydro has long recognized that the high quality and performance required in nuclear generating stations start in the design process and can best be achieved through an adequate and proper quality engineering programme in design. The current approach has evolved over a period of six years and represents a meaningful and effective series of requirements, functions and activities, which are used to ensure safety, reliability, economy and environmental acceptability of nuclear generating stations. (author).

252

Liquid metal reactor cover gas purification and analysis in the USA  

International Nuclear Information System (INIS)

Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.

1986-09-24

253

FFTF operating experience, 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some in excess of 80 MWd/Kg.

1984-04-09

254

Constitution of a centralised data base for the internal quality control in radiotherapy; Constitution d'une base de donnees centralisee pour le controle de qualite interne en radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to implement a centralised data base of internal quality control in radiotherapy according to the criteria of the decree of A.f.s.s.a.p.s. (French agency of sanitary safety of health products on 27 july 2007, about the internal quality control of external radiotherapy facilities. The software on one year meets the objectives: compliance by comparison with A.f.s.s.a.p.s. criteria but particularly optimization of the centralisation and analysis of the internal quality controls. (N.C.)

2009-10-15

255

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).

1980-01-01

256

Alteration in reactor installation (addition of Unit 2) in the Sendai Nuclear Power Station of Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.

1980-10-01

257

Status Report of Simulated Space Radiation Environment Facility  

Energy Technology Data Exchange (ETDEWEB)

The technology for performance testing and improvement of materials which are durable at space environment is a military related technology and veiled and securely regulated in advanced countries such as US and Russia. This core technology cannot be easily transferred to other country too. Therefore, this technology is the most fundamental and necessary research area for the successful establishment of space environment system. Since the task for evaluating the effects of space materials and components by space radiation plays important role in satellite lifetime extension and running failure percentage decrease, it is necessary to establish simulated space radiation facility and systematic testing procedure. This report has dealt with the status of the technology to enable the simulation of space environment effects, including the effect of space radiation on space materials. This information such as the fundamental knowledge of space environment and research ...

2007-11-15

258

Overview of hazardous-waste regulation at federal facilities  

Energy Technology Data Exchange (ETDEWEB)

This report is organized in a fashion that is intended to explain the legal duties imposed on officials responsible for hazardous waste at each stage of its existence. Section 2 describes federal hazardous waste laws, explaining the legal meaning of hazardous waste and the protective measures that are required to be taken by its generators, transporters, and storers. In addition, penalties for violation of the standards are summarized, and a special discussion is presented of so-called imminent hazard provisions for handling hazardous waste that immediately threatens public health and safety. Although the focus of Sec. 2 is on RCRA, which is the principal federal law regulating hazardous waste, other federal statutes are discussed as appropriate. Section 3 covers state regulation of hazardous waste. First, Sec. 3 explains the system of state enforcement of the federal RCRA requirements on hazardous waste within their borders. Second, Sec. 3 discusses two peculiar ...

1982-05-01

259

Heavy water reactor facility large-scale containment cooling test program  

Science.gov (United States)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-01-01

260

Heavy water reactor facility large-scale containment cooling test program  

International Nuclear Information System (INIS)

The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic cylinder and dome surface area ratios than ...

1992-11-15

261

G3 model of gas and liquid migration from grout containing radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

Grout has been evaluated as a means of containing low-level radioactive waste for long-term disposal. Concerns about hydrogen and reactive gas generation in the Hanford Site grout disposal facility lead to the development of the G3 model, which has predicted buildup of radiolytically formed gases in the grout region and their migration to air-filled regions. The G3 model is a one-dimensional code that couples models of gas diffusion with two-phase gas and liquid flow. It was coupled to a compartment diffusion model and these models predicted the concentrations of hydrogen I nitrous oxide, and other gases in air-filled regions of the grout disposal facility. The results have served as the technical basis for safety studies. A unique finding of the G3 model was that a liquid return, or expulsion of unbound liquid from the grout region, could occur. This liquid return is driven by displacement caused by gas bubbles that form ...

1994-11-01

262

Fuel management at the Petten high flux reactor  

Energy Technology Data Exchange (ETDEWEB)

Several years ago the shipment of spent fuel of the High Flux Reactor (HFR) at Petten has come to a standstill resulting in an ever growing stock of fuel elements that are labelled 'fully burnt up'. Examination of those elements showed that a reasonably number of them have a relatively high {sup 235}U mass left. A reactor physics analysis showed that the use of such elements in the peripheral core zone allows the loading of four instead of five fresh fuel elements in many cycle cores. For the assessment of safety and performance parameters of HFR cores a new calculational tool is being developed. It is based on AEA Technology's Reactor physics code suite Winfrith Improved Multigroup Scheme (WIMS). NRG produced pre- and post-processing facilities to feed input data into WIMS's 2D transport code CACTUS and to extract relevant parameters from the output. The processing facilities can be used ...

1999-07-01

263

FFTF [Fast Flux Test Facility] Integrated Leak Rate Test Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The multiple computer ...

264

Environmental risk assessment. A method for determination and evaluation of the risks of harmful changes in air, water and soils due to hazardous substances which are handled in technical facilities - aspects which are relevant to the Environmental Liabilities Law. Die Beurteilung von Umweltrisiken. Eine Methode zur Ermittlung und Bewertung der Risiken einer schaedlichen Veraenderung der Umweltmedien durch umweltgefaehrdende Stoffe in technischen Anlagen unter dem Aspekt des Umwelthaftungsgesetzes  

Energy Technology Data Exchange (ETDEWEB)

The criterion the study is based on in evaluating environmental risks is the possibility of harmful changes in air, water and soils rather than the harmful environmental impacts these changes are caused by. The two significant criteria, i.e. the evaluated environmental hazards potentials or 'value parameters', and the evaluated damage-to-the-environment probabilities or 'safety parameters', reveal the respective environmental risks or 'risk factors'. These risk factors are classified by 23 environmental risk parameters for differentiation between low-risk and high-aid for pollution abatement measures provided that one fixes acceptance limits for the environmental parameters. As a rule the environmental risks of technical facilities which handle hazardous materials can be evaluated appropriately and the results can be compared. (orig./HSCH).

1992-02-07

265

DWPF waste form compliance plan (Draft Revision)  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy currently has over 100 million liters of high-level radioactive waste in storage at the Savannah River Site (SRS). In the late 1970's, the Department of Energy recognized that there were significant safety and cost advantages associated with immobilizing the high-level waste in a stable solid form. Several alternative waste forms were evaluated in terms of product quality and reliability of fabrication. This evaluation led to a decision to build the Defense Waste Processing Facility (DWPF) at SRS to convert the easily dispersed liquid waste to borosilicate glass. In accordance with the NEPA (National Environmental Policy Act) process, an Environmental Impact Statement was prepared for the facility, as well as an Environmental Assessment of the alternative waste forms, and issuance of a Record of Decision (in December, 1982) on the waste form. The Department of Energy, recognizing that ...

1991-01-01

266

DWPF waste form compliance plan (Draft Revision)  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy currently has over 100 million liters of high-level radioactive waste in storage at the Savannah River Site (SRS). In the late 1970`s, the Department of Energy recognized that there were significant safety and cost advantages associated with immobilizing the high-level waste in a stable solid form. Several alternative waste forms were evaluated in terms of product quality and reliability of fabrication. This evaluation led to a decision to build the Defense Waste Processing Facility (DWPF) at SRS to convert the easily dispersed liquid waste to borosilicate glass. In accordance with the NEPA (National Environmental Policy Act) process, an Environmental Impact Statement was prepared for the facility, as well as an Environmental Assessment of the alternative waste forms, and issuance of a Record of Decision (in December, 1982) on the waste form. The Department of Energy, recognizing that start-up of ...

1991-12-31

267

Control of microbially generated hydrogen sulfide in produced waters  

Energy Technology Data Exchange (ETDEWEB)

Production of hydrogen sulfide in produced waters due to the activity of sulfate-reducing bacteria (SRB) is a potentially serious problem. The hydrogen sulfide is not only a safety and environmental concern, it also contributes to corrosion, solids formation, a reduction in produced oil and gas values, and limitations on water discharge. Waters produced from seawater-flooded reservoirs typically contain all of the nutrients required to support SRB metabolism. Surface processing facilities provide a favorable environment in which SRB flourish, converting water-borne nutrients into biomass and H{sub 2}S. This paper will present results from a field trial in which a new technology for the biochemical control of SRB metabolism was successfully applied. A slip stream of water downstream of separators on a produced water handling facility was routed through a bioreactor in a side-steam device where microbial growth was allowed to ...

1995-12-31

268

Percolation-theory and fuzzy rule-based probability estimation of fault leakage at geologic carbon sequestration sites  

Energy Technology Data Exchange (ETDEWEB)

Leakage of CO{sub 2} and displaced brine from geologic carbon sequestration (GCS) sites into potable groundwater or to the near-surface environment is a primary concern for safety and effectiveness of GCS. The focus of this study is on the estimation of the probability of CO{sub 2} leakage along conduits such as faults and fractures. This probability is controlled by (1) the probability that the CO{sub 2} plume encounters a conductive fault that could serve as a conduit for CO{sub 2} to leak through the sealing formation, and (2) the probability that the conductive fault(s) intersected by the CO{sub 2} plume are connected to other conductive faults in such a way that a connected flow path is formed to allow CO{sub 2} to leak to environmental resources that may be impacted by leakage. This work is designed to fit into the certification framework for geological CO{sub 2} storage, which represents vulnerable resources such as potable groundwater, health and ...

2009-05-01

269

Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis  

International Nuclear Information System (INIS)

As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the corner of the calandria subshells and annular ...

2009-07-01

270

Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521; Validierung des CFD codes FLUENT anhand der Nachrechnung des ROCOM Experimentes T665521  

Energy Technology Data Exchange (ETDEWEB)

During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at ...

2005-05-01

271

Verification of the CFD code FLUENT by post test calculation of the ROCOM experiment T665521  

International Nuclear Information System (INIS)

During the last years one focus of German PWR safety analysis was boron dilution events with the potential of reactivity transients. Coolant with a low boron concentration could be collected in localized areas of the reactor coolant system e.g. by separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux- condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. The TUeV NORD SysTec was charged by German supervisory authorities with the assessment of the safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses shall demonstrate that boron dilution events cannot lead to recriticality of the core. Hence the boron concentration at ...

2005-05-01

272

Validation of the CFD code fluent by post-test calculation of a density-driven ROCOM experiment  

Energy Technology Data Exchange (ETDEWEB)

During the last years, boron dilution events with the potential of reactivity transients were an important issue of German PWR safety analyses. A coolant with a low-boron concentration could be collected in localized areas of the reactor coolant system, e.g., by separation of a borated reactor coolant into highly concentrated and diluted fractions (inherent dilution) which can occur during reflux-condenser heat transfer after a small break loss of coolant accident with a limited availability of the emergency core cooling systems. During the course of follower core assessments, TUV NORD SysTec appraises safety analyses of boron dilution events presented by the utilities. These analyses are based on the simulation of boron dilution and transport processes in conjunction with a number of dedicated experiments. The analyses demonstrate that boron dilution events cannot lead to recriticality of the core. Hence, the boron concentration at the core ...

2007-09-15

273

Activities performed within the program of Nuclear Safety Research on structural and cladding materials for innovative reactor systems able to transmute nuclear waste  

International Nuclear Information System (INIS)

Full text: The transmutation of nuclear waste to reduce the burden on a geological repository is a relevant topic within the Program of Nuclear Safety Research of the Research Centre Karlsruhe. Several studies have confirmed that a high efficiency of transmutation of actinides is reached in fast neutron spectrum reactor system. Therefore, an important effort is dedicated to the study of transmutation strategies with different fast reactors and their associated technologies. Moreover, in international contexts as Generation IV International Forum (GIF) and Sustainable Nuclear Energy Technology Platform (SNETP), fast reactors are considered in the frame of sustainable development of nuclear energy and reduction of waste. The systems that are currently under investigation, in the frame of the different fuel cycle scenarios, are liquid metal cooled and gas cooled fast reactors as well as Accelerator Driven Sub-critical Transmutation devices (ADS). ...

2009-10-05

274

Reactivity surveillance experiments with the engineering mock-up core of the fast flux test facility reactor  

International Nuclear Information System (INIS)

An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified source multiplication method calibrated near ...

275

Measurement and interpretation of delayed photoneutron effects in multizone criticals with partial D{sub 2}O moderation  

Energy Technology Data Exchange (ETDEWEB)

The effective fraction of delayed photoneutrons ({beta}{sup ph}) has been theoretically defined and experimentally determined in various different configurations of the LWR-PROTEUS critical facility. The peculiarity lies in the fact that the reactor has D{sub 2}O in only one of the four fuelled zones, thus D({gamma},n)H reactions take place mainly in this region. The work is divided into three parts. The first part is devoted to the description of the LWR-PROTEUS facility and to the measurements of {beta}{sup ph}. These experimental values are derived from standard inverse-kinetics analysis of neutron flux decay experiments for each of seven different configurations, with nine additional groups of neutron precursors to account for photoneutron effects. In the second part, the coupled neutron and gamma Boltzmann equations are reduced to exact point kinetics equations using the photon infinite-velocity approximation, and then ...

2003-11-01

276

Nuclear safety culture star-class assessment system based BP neural network  

International Nuclear Information System (INIS)

In order to build the safety culture for nuclear power industry, it is important to evaluate the safety culture scientifically. Considering the traits of safety culture in the nuclear power industry, 24 safety culture assessment indexes are established from 4 aspects such as Safety consciousness, Safety attitude, Safety action and Safety actuality by using the SMART criteria. Safety culture star-class assessment criterion is presented and safety culture star-class assessment system is developed by using Visual Basic 6.0 and BP neural network. The system has a better generalization ability, and it can show exactly which phase the safety culture is in. Experimental results show that safety culture star-class assessment is practical and easy ...

2007-02-01

277

University of Central Lancashire - Facilities  

Wastenet

...specialised laboratories for pharmaceutics, tissue culture and molecular biology Excellent Laboratory Facilities Tissue Culture Facilities Molecular Biology Laboratory ...

278

ESBWR related passive decay heat removal tests in PANDA  

International Nuclear Information System (INIS)

A number of test series to investigate passive safety systems for the next generation of Light Water Reactors have been performed in the PANDA multi-purpose facility at the Paul Scherrer Institut (PSI). The large scale thermal-hydraulic test facility allows to investigate LWR containment phenomena and system behaviour. PANDA was first used to examine the Passive Containment Cooling System (PCCS) for the Simplified Boiling Water Reactor (SBWR). In 1996 new test series were initiated; all related to projects of the EC Fourth Framework Programme on Nuclear Fission Safety. One of these projects (TEPSS) is focused on the European Simplified Boiling Water Reactor (ESBWR). The ESBWR containment features and PCCS long-term post LOCA response were investigated in PANDA. The PCCS start-up was demonstrated, the effect of nitrogen hidden somewhere in the drywell and released later in the transient was simulated and ...

1999-04-19

279

Annual report on heavy water reactor fuel fabrication  

Energy Technology Data Exchange (ETDEWEB)

The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing techniques, and raising the efficiency of ...

1994-03-01

280

Feasibility of /sup 252/Cf source driven neutron noise measurements in water moderated reactors  

Energy Technology Data Exchange (ETDEWEB)

Previous experiments in fast critical assemblies demonstrated a method of determining reactivity from power spectral density measurements with /sup 252/Cf. This method determines reactivity from properties of the reactor only at the subcritical state of interest, thus it does not require a calibration near delayed criticality. The interpretation of the measured data to obtain reactivity does not require knowledge of the relative or absolute values of the source intensity, knowledge of the detection efficiencies, or knowledge of the detection instrumentation frequency responses. An experiment was performed at the Pool Critical Assembly to evaluate the possibility of /sup 252/Cf source driven neutron noise spectral density measurements in light water moderated reactors. This experiment showed that using commercially available detectors, such measurements can be performed in a reasonable time, that is, the measurement of the ...

1980-01-01

281

Rainfall effect on single-vehicle crash severities using polychotomous response models.  

Science.gov (United States)

As part of the Wisconsin road weather safety initiative, the objective of this study is to assess the effects of rainfall on the severity of single-vehicle crashes on Wisconsin interstate highways utilizing polychotomous response models. Weather-related factors considered in this study include estimated rainfall intensity for 15 min prior to a crash occurrence, water film depth, temperature, wind speed/direction, stopping sight distance and deficiency of car-following distance at the crash moment. For locations with unknown weather information, data were interpolated using the inverse squared distance method. Non-weather factors such as road geometrics, traffic conditions, collision types, vehicle types, and driver and temporal attributes were also considered. Two types of polychotomous response models were compared: ordinal logistic and sequential logistic regressions. The sequential logistic regression was tested with forward and backward formats. Comparative ...

2009-08-14

282

Current status of siting a new near surface repository in Romania  

International Nuclear Information System (INIS)

Full text: The site selection process for a near surface repository dedicated for the radioactive waste resulted from the Cernavoda NPP operation and decommissioning started early in 90's. Each site selection stage included the collection of data from specific field and laboratory works as well as the appropriate safety performance evaluation. In order to assess/confirm the performance of the natural barrier of the Saligny site, the radionuclide concentration in the disposal system compartments has been evaluated, as complementary safety indicator of repository. The siting process was made in accordance with national and international regulations and standards and using a conceptual design similar to those used at L'Aube (France), ElCabril (Spain) or Mohovce (Slovak Republic). ANDRAD, the Romanian waste management organization that has continued the siting process in the last three years applied and obtained a partial siting license from CNCAN ...

2009-05-27

283

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...

2005-07-01

284

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center ...

2007-07-01

285

Safety in the forefront  

Energy Technology Data Exchange (ETDEWEB)

Safety in general and harmonization of International Maritime Organization rules on mobile offshore drilling rig operation in particular are discussed. The improvement of the industry's safety record is also discussed.

1985-02-01

286

Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama. Wilsonville ACL R and D Facility material balance procedure. Topical Report No. 11  

Science.gov (United States)

Prior to 1978, the Wilsonville Advanced Coal Liquefaction facility material balance surrounded only the thermal liquefaction unit and involved analyses of only the slurry stream and individual gas streams. The distillate solvent yield was determined by difference. Subsequently, several modifications and additional process units were introduced to this single unit system. With the inclusion of the deashing unit in 1978 and the catalytic hydrogenation unit in 1981, the process has evolved into a sophisticated two-stage coal liquefaction process and has the potential for various modes of integration. This report presents an elemental balancing procedure and a simplified presentation format that is sufficiently flexible to meet current and future needs. The development of the elemental balancing technique and the relevant computer programs to handle the calculations have been addressed. This will be useful in modelling individual unit performance as well as determining ...

1984-09-01

287

ESTABLISHING FINAL END STATE FOR A RETIRED NUCLEAR WEAPONS PRODUCTION REACTOR; COLLABORATION BETWEEN STAKEHOLDERS, REGULATORS, AND THE FEDERAL GOVERNMENT - 11052  

Science.gov (United States)

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy nuclear facility located along the Savannah River (SRS) near Aiken, South Carolina. Nuclear weapons material production began in the early 1950s, utilizing five production reactors. In the early 1990s all SRS production reactor operations were terminated. The first reactor closure end state declaration was recently institutionalized in a Comprehensive Environmental Response and Compensation and Liability Act (CERCLA) Early Action Record of Decision. The decision for the final closure of the 318,000 square foot 105-P Reactor was determined to be in situ decommissioning (ISD). ISD is an acceptable and cost effective alternative to off-site disposal for the reactor building, which will allow for consolidation of remedial action wastes generated from other cleanup activities within the P Area. ISD is considered protective by the regulators, U. S. Environmental Protection Agency (US ...

2010-11-17

291

Update of the management strategy for Oak Ridge National Laboratory Liquid Low-Level Waste  

Energy Technology Data Exchange (ETDEWEB)

The strategy for management of the Oak Ridge National Laboratory`s (ORNL) radioactively contaminated liquid waste was reviewed in 1991. The latest information available through the end of 1990 on waste characterization, regulations, US Department of Energy (DOE) budget guidance, and research and development programs was evaluated to determine how the strategy should be revised. Few changes are needed to update the strategy to reflect new waste characterization, research, and regulatory information. However, recent budget guidance from DOE indicates that minimum funding will not be sufficient to accomplish original objectives to upgrade the liquid low-level waste (LLLW) system to comply with the Federal Facilities Agreement, provide long-term LLLW treatment capability, and minimize environmental, safety, and health risks. Options are presented that might allow the ORNL LLLW system to continue operations temporarily, but they would significantly ...

1995-04-01

292

Status of the ORNL liquid low-level waste management upgrades  

Energy Technology Data Exchange (ETDEWEB)

The strategy for management of the Oak Ridge National Laboratory`s (ORNL`s) radioactively contaminated liquid waste was reviewed. The latest information on waste characterization, regulations, US Department of Energy (DOE) budget guidance, and research and development programs was evaluated to determine how the strategy should be revised. Few changes are needed to update the strategy to reflect new waste characterization, research, and regulatory information. However, recent budget guidance from DOE indicates that minimum funding will not be sufficient to accomplish original objectives to upgrade the liquid low-level waste (LLLW) system to be in compliance with the Federal Facilities Agreement compliance, provide long-term LLLW treatment capability, and minimize Environmental Safety & Health risks. Options are presented that might allow the ORNL LLLW system to continue operations temporarily but significantly reduce its capabilities to ...

1995-08-01

293

Chalon/Saint-Marcel manufacturing plant; L'usine de Chalon/Saint-Marcel  

Energy Technology Data Exchange (ETDEWEB)

AREVA is the world leader in the design and construction of nuclear power plants, the manufacture of heavy components, and the supply of nuclear fuel and nuclear services such as maintenance and inspection. The Equipment Division provides the widest range of nuclear components and equipment, manufactured at its two facilities in Jeumont, northern France, and St. Marcel, in Burgundy. The St. Marcel plant, set on 35 ha (87.5 acres) near Chalon-sur-Saone, was established in 1973 in a region with a long history of specialized metalworking and mechanical activities to meet the demand for non-military nuclear requirements in France. The site offers two advantages: - excellent facilities for loading and transporting heavy components on the Saone river, - it's proximity to other group sites. Since its completion in 1975, the Chalon/St. Marcel facility has manufactured all the heavy components for French pressurized water ...

2008-07-01

294

Analysis of enclosed sodium pool fire scenario in sodium fire experimental facility  

International Nuclear Information System (INIS)

Liquid sodium is used as coolant in Fast Breeder Reactors (FBR). There is a likelyhood of sodium spillage in ambient air in the Steam Generator Building (SGB) of the FBR plant. Due to high chemical reactivity with oxygen, especially at temperatures greater than 573 K, it catches fire very easily. In order to carryout safety related experimental studies for different modes of sodium fires and to develop suitable mathematical models for the assessment of their consequences, an experimental facility (SFEF, Sodium Fire Experimental Facility) is being setup a IGCAR, Kalpakkam. The SFEF is having a 540 m"3 volume experimental hall. Stainless steel linear will be provided on the inside surfaces of experimental hall walls, ceiling and floor. Analysis has been carried out for enclosed sodium pool fire scenarios in SFEF by using sodium pool fire code SOFIRE II, which estimates the thermal transients like pressure rise, gas ...

2007-04-22

295

An overview of AECL's participation in the Korean Wolsung Tritium Removal Facility Project (WTRF)  

International Nuclear Information System (INIS)

Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the third step the tritium is packaged for long-term storage. The WTRF will enable KHNP to ...

2007-11-07

296

Validation and verification of the ORNL Monte Carlo codes for nuclear safety analysis  

International Nuclear Information System (INIS)

The process of ensuring the quality of computer codes can be very time consuming and expensive. The Oak Ridge National Laboratory (ORNL) Monte Carlo codes all predate the existence of quality assurance (QA) standards and configuration control. The number of person-years and the amount of money spent on code development make it impossible to adhere strictly to all the current requirements. At ORNL, the Nuclear Engineering Applications Section of the Computing Applications Division is responsible for the development, maintenance, and application of the Monte Carlo codes MORSE and KENO. The KENO code is used for doing criticality analyses; the MORSE code, which has two official versions, CGA and SGC, is used for radiation transport analyses. Because KENO and MORSE were very thoroughly checked out over the many years of extensive use both in the United States and in the international community, the existing codes were open-quotes baselined.close quotes This means that ...

1993-11-14

297

Thermal-hydraulic limitations on water-cooled limiters  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on current design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, especially under ...

1984-08-01

298

Thermal-hydraulic limitations on water-cooled fusion reactor components  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, ...

1986-01-01

299

Thermal-hydraulic limitations on water-cooled fusion reactor components  

Energy Technology Data Exchange (ETDEWEB)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, ...

1987-01-01

300

Thermal-hydraulic limitations on water-cooled fusion reactor components  

International Nuclear Information System (INIS)

An assessment of the cooling requirements for fusion reactor components, such as the first wall and limiter/divertor, was carried out using pressurized water as the coolant. In order to establish the coolant operating conditions, a survey of the literature on departure from nucleate boiling, critical heat flux, asymmetrical heating and heat transfer augmentation techniques was carried out. The experimental data and the empirical correlations indicate that thermal protection for the fusion reactor components based on conventional design concepts can be provided with an adequate margin of safety without resorting to either high coolant velocities, excessive coolant pressures, or heat transfer augmentation techniques. If, however, the future designs require unconventional shapes or heat transfer enhancement techniques, experimental verification would be necessary since no data on heat transfer augmentation techniques exist for complex geometries, ...

1986-12-07

301

The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors  

Energy Technology Data Exchange (ETDEWEB)

Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that ...

1996-01-01

302

The experience of obsolete item identification and solution in CANDU NPPs  

International Nuclear Information System (INIS)

Design and procurement of equipment for nuclear power plant took place in late 1970's. A large number of originally installed equipment is obsolete. The manufacturer's do not support their products or have discontinued their production due to technological evolutions or lack of product demand. Lack of spares affects the performance of obsolete equipment and has a negative impact on plant safety and plant production. A proactive approach to address obsolescence is necessary to ensure critical spares are always available when needed. This is an ongoing effort and requires a program to be in place to resolve immediate and longterm issues. A cross-functional team with adequate external exposure is needed to administer the obsolescence program. CANDU utilities and CANDU Owners Group(COG) has taken initiatives to identify lack of equipment spares in the members' plant. The equipment replacement information collected from each CANDU nuclear power ...

2010-10-01

303

Safety analysis report: packages. Pu oxide and Am oxide shipping cask (Packaging of fissile and other radioactive materials. Final report  

Energy Technology Data Exchange (ETDEWEB)

The PuO/sub 2/ cask or SP 5320-2 and 3 cask is designed for surface shipment of americium or plutonium. The cask design was physically tested to demonstrate that it met the criteria specified in US ERDA Manual Chapter 0529, and Chapter I, Interstate Commerce Commission. The package has been assessed for transport of up to 357 grams of plutonium (403 grams PuO/sub 2/ powder) and up to 176 grams of americium (200 grams AmO/sub 2/ powder), having a maximum decay heat of 203 watts. Criticality evaluation alone would allow the shipment as Fissile Class II but the radiation level of the cask, measured at the time of shipment, may exceed 50 mrem/h at the surface and require shipment as Fissile Class III. Sample calculations address only the more restrictive of the two materials, which in most cases is /sup 238/PuO/sub 2/.

1980-05-01

304

Review of fires and fire control methods for nuclear air cleaning systems  

International Nuclear Information System (INIS)

The nuclear power industry has experienced four carbon based adsorbent fires in its history, one was of the Monticello Standby Gas Treatment System and other three were in various off-gas delay beds. Although, some of the latter may not be classified as a full fledged fires. There were a number of experiments performed relating to igniting carbon beds and experiments relating to attempts at extinguishing set fires reported in the literature. Review of these experiments indicates that fire resulting from decay heat of adsorbed radioactive iodine is not justified even under the somewhat unrealistic source terms still in effect. At the same time the non-nuclear chemical industry application of carbon base adsorbents for solvent recovery has resulted in numerous fires and significant property losses. Fire control systems installed in nuclear air cleaning systems in the US consists of water deluge. Accidental initiation of these systems has occurred in excess of one hundred times in US ...

1987-05-01

305

Organic farming in the Nordic countries--animal health and production.  

Science.gov (United States)

Organic farming (or ecological agriculture) is of growing importance in the agricultural sector worldwide. In the Nordic countries, 1-10% of the arable land was in organic production in 1999. Organic farming can be seen as an approach to agriculture where the aim is to create integrated, humane, environmentally and economically sustainable agricultural production systems. Principles like nutrient recycling, prevention rather than treatment and the precautionary principle are included in aims and standards. Animal welfare is another hallmark of organic livestock production but despite this, several studies have indicated severe health problems e.g. in organic poultry production in Denmark. Also the quality of animal food products in relation to human health, particularly the risk of zoonotic infections, has been debated. For these reasons there is a need for improvement of production methods and animal health status. Vets play an important role in this development through work in ...

2001-01-01

306

Observation of DNB phenomena by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

In the design of LWRs, the forecast of critical heat flux (CHF) is important. The existing CHF correlation equations include the arbitrary constants based on experimental data, therefore, their range of application is limited. For advancing the research and development of high conversion LWRs or passive safety reactors, the development of more general CHF forecasting technique has been demanded. In order to elucidate the mechanism of CHF occurrence and construct the general forecasting model based on physical phenomena, the detailed observation of flow phenomena near a heat generation surface is indispensable. The experiment of observing boiling two-phase flow and CHF phenomena by applying neutron radiography technique was carried out. The utilization of neutron radiography in the field of heat-transferring flow is explained. The experimental setup and the experimental method, the experimental conditions, and the results of the observations of ...

1994-07-01

307

Laser eye protection. Interim report, July 1989-January 1990  

Energy Technology Data Exchange (ETDEWEB)

Laser applications have proliferated in recent years and, as to be expected, their presence is no longer confined to the laboratory or places where access to their radiation can be easily controlled. One obvious application where this is so is in military operations where various devices such as laser range finders, target designators, and secure communications equipment elevate the risk of exposure, specifically eye exposure, to unacceptable levels. Although the need for eye protection in the laboratory and other controlled areas has been appreciated since the invention of the laser, the use of lasers in circumstances where safety or the risk of temporary loss of vision, which can not always be ensured by administrative procedures, has made adequate eye protection essential. It is the critical nature of many military operations that has driven the search for eye protection against both nuclear and laser radiation. At the same time, the ...

1990-01-01

308

Emerging technologies  

Energy Technology Data Exchange (ETDEWEB)

The mission of the Emerging Technologies thrust area at Lawrence Livermore National Laboratory is to help individuals establish technology areas that have national and commercial impact, and are outside the scope of the existing thrust areas. We continue to encourage innovative ideas that bring quality results to existing programs. We also take as our mission the encouragement of investment in new technology areas that are important to the economic competitiveness of this nation. In fiscal year 1992, we have focused on nine projects, summarized in this report: (1) Tire, Accident, Handling, and Roadway Safety; (2) EXTRANSYT: An Expert System for Advanced Traffic Management; (3) Odin: A High-Power, Underwater, Acoustic Transmitter for Surveillance Applications; (4) Passive Seismic Reservoir Monitoring: Signal Processing Innovations; (5) Paste Extrudable Explosive Aft Charge for Multi-Stage Munitions; (6) A Continuum Model for Reinforced Concrete at High Pressures and ...

1993-03-01

309

Development of a best estimate auditing code for CANDU thermal hydraulic safety analysis  

Energy Technology Data Exchange (ETDEWEB)

The main purpose of this study is to develop a thermal hydraulic auditing code for the CANDU reactor, modifying the model of existing PWR auditing tool , i.e. RELAP5/MOD3. This scope of project is a fourth step of the whole project, applying the RELAP5/MOD3/CANDU+ version for the real CANDU plant LOCA Analysis and D2O leakage incident. There are three main models under investigation, i.e. Moody critical flow model, flow regime model of horizontal CANDU bundle, and fuel element heatup model when the stratification occurs, especially when CANDU LOCA is tested. Also, for Wolsung unit 1 D2O leakage incident analysis, the plant behavior is predicted with the newly developed version for the first 1000 seconds after onset of the incident, with the main interest aiming for system pressure, level control system, and thermal hydraulic transient behavior of the secondary system. The model applied for this particular application includes heat transfer model of nuclear fuel ...

2001-03-01

310

Determination of vapor-liquid equilibrium data and decontamination factors needed for the development of evaporator technology for use in volume reduction of radioactive waste streams  

Energy Technology Data Exchange (ETDEWEB)

A program is currently in progress at Argonne National Laboratory to evaluate and develop evaporator technology for concentrating radioactive waste streams. By concentrating radioactive waste streams, disposal costs can be significantly reduced. To effectively reduce the volume of waste, the evaporator must achieve high decontamination factors so that the distillate is sufficiently free of radioactive material. One technology that shows a great deal of potential for this application is being developed by LICON, Inc. In this program, Argonne plans to apply LICON`s evaporator designs to the processing of radioactive solutions. Concepts that need to be incorporated into the design of the evaporator include, criticality safety, remote operation and maintenance, and materials of construction. To design an effective process for concentrating waste streams, both solubility and vapor-liquid equilibrium data are needed. The key issue, however, is the ...

1993-10-01

311

Design modifications in 540 MWe and its impact on the dose rates  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. TAPS Unit-4 is the first Pressurized Heavy Water Reactor of 540 MWe electrical capacity. This unit was made critical on March 6, 2005. In-depth review of radiation safety was done to identify the impact of design modification on dose rates at various locations and on the equipment's. Problems encountered in controlling the dose rates in 220 MWe electrical are eliminated by appropriate design modifications. Due to higher capacity of the unit there are design changes in major systems such as reactor core, primer heat transport system, moderator system, reactor regulation and protection systems. Reactor operations and maintenance activities during shut down contributes to exposure of the employees. Based on the experience gained in the operation of 220 MWe, design modifications incorporated in TAPS unit-4 and dose rate measurements carried out at 90 % full power, through ...

2005-11-23

312

Design improvements and operational experience of programmable digital comparator system  

International Nuclear Information System (INIS)

Application of Programmable Digital Comparator System (PDCS) in NPP is to monitor large number of plant parameters and generate contact outputs for reactor trip, reactor setback, process interlocks etc. when parameters cross their operational bounds. Till NAPS these functions are achieved through individual Indicating Alarm Meters (IAM). PDCS used for the first time in KAPS replaces these IAMs. Since its inception, PDCS has undergone improvements in design, incorporates additional functionalities/enhanced features. Dedicated PDCS is provided in TAPP-3 and 4 for protection function. System re-configurability, on-line inter channel comparison of safety critical process parameters' values, Graphic User Interface etc. are other enhancements. From KAPS to TAPP-4 system has given many years of almost trouble-free operation. Commissioning of TAPP-3 system has been very smooth. Objective of the paper is to describe the advantage of the new system, its ...

2006-11-13

313

Core Heat Transfer Model Validation of the TASS/SMR-S Code using the Bennett's Test  

International Nuclear Information System (INIS)

The SMART (System-integrated Modular Advanced ReacTor) which is a 330 MWt advanced integral PWR was developed by the KAERI (Korea Atomic Energy Institute) for electricity generation and seawater desalination. A thermal hydraulic evaluation and analysis of the SMART is performed by the TASS /SMR-S (Transient And Setpoint Simulation/System integrated Modular Reactor-Safety). The TASS/SMR-S code has various models reflecting the design features of the SMART such as the drift flux model, the core models (core power and core heat transfer model), the component models, and the specific models. One of the core models is the core heat transfer model. The role of this model is to calculate the heat flux and radial temperature profiles at a fuel rod surface using the relevant heat transfer correlations for all of the heat transfer modes. Also it is modeled to meet the requirements of the 10 CFR 50 appendix K EM model for the CHF (Critical Heat Flux) and ...

2010-10-01

314

Conceptual study of advanced PWR systems. A study of passive and inherent safety design concepts for advanced light water reactors  

Energy Technology Data Exchange (ETDEWEB)

The five thermal-hydraulic concepts chosen for advanced PWR have been studied as follows: (1) Critical Heat Flux: Review of previous works, analysis of parametric trends, analysis of transient CHF characteristics, extension of the CHF date bank, survey and assessment of correlations, design of a intermediate-pressure CHF test loop have been performed. (2) Passive Cooling Concepts for Concrete Containment system: Review of condensation phenomena with noncondensable gases, selection of a promising concept (i.e., use of external condensers), design of test loop according to scaling laws have been accomplished. and computer programs based on the control-volume approach, and the conceptual design of test loop have been accomplished. (4) Fluidic Diode Concepts: Review of previous applications of the concept, analysis major parameters affecting the performance, development of a computational code, and conceptual investigation of the verification test loop have been ...

1995-08-01

315

Competency build up, sustained performance enhancement of human resource through effective man power planning, training and proper safety culture and organizational climate  

International Nuclear Information System (INIS)

Human resource competence building and continued enhancement of performance is the most vital input for safe and reliable operations of a Nuclear Power Plant. Integrated planning leading to the decision of timely selection of optimum number of fresh people and deployment of experienced manpower with desired lead time is inevitable to achieve the above objective. For safe and reliable plant operation human performance analysis followed by suggestive measures to improve the same is needed. Corrective or strengthening input may be in terms of training, work environment, motivations, organizational culture and climate, leadership and prevailing environmental force and bio-rhythm of individuals with critical days are to be worked out The adequacy in training and development not only gives safe and reliable plant operations but results in greater employee satisfaction and self esteem as well. As of date, in the present vibrant global scenario, only the organization which ...

2006-11-13

316

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements taken so far have revealed brand new information and data on radiological composition ...

1996-09-16

317

Advanced evaporator technology progress report FY 1992  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work that was completed in FY 1992 on the program {open_quotes}Technology Development for Concentrating Process Streams.{close_quotes} The purpose of this program is to evaluate and develop evaporator technology for concentrating radioactive waste and product streams such as those generated by the TRUEX process. Concentrating these streams and minimizing the volume of waste generated can significantly reduce disposal costs; however, equipment to concentrate the streams and recycle the decontaminated condensates must be installed. LICON, Inc., is developing an evaporator that shows a great deal of potential for this application. In this report, concepts that need to be incorporated into the design of an evaporator operated in a radioactive environment are discussed. These concepts include criticality safety, remote operation and maintenance, and materials of construction. Both solubility and vapor-liquid equilibrium ...

1995-01-01

318

Decomissioning Strategies for Facilities Using Radioactive Material  

CERN Document Server

Decomissioning Strategies for Facilities Using Radioactive Material

2007-01-01

319

Regulatory Framework for Advanced Fuel Cycle Facility Using Pyroprocess in Korea  

International Nuclear Information System (INIS)

Nuclear power plants of 20 units of in Korea are generating about 700 MTU of spent fuels annually. The inventory of spent fuels in Korea were estimated about 10,087.07 MTU at end of 2008, and the storage space of spent fuels won't be available any more at 2016 due to the saturation of the spent fuel pools in the plants. In addition, in order to reduce carbon emission and correspond to the enormous electricity demand in Korea, 8 units of nuclear power plants are under construction and several more plants are under planning. The 100,000 MTU of spent fuel inventory are expected by the year of 2095 in Korea. Therefore, short term and long term of spent fuel management plans are under discussion and implementation in Korea. As a short term of spent fuel management strategy for the target year of 2016, central or local spent fuel dry interim storage options are mostly under discussion. As a long term of management plan, fast reactor and advanced fuel cycle R and D plan were approved by 255th ...

2010-10-01

322

Safety culture development at Daya Bay NPP  

International Nuclear Information System (INIS)

From view on Organization Behavior theory, the concept, development and affecting factors of safety culture are introduced. The focuses are on the establishment, development and management practice for safety culture at Daya Bay NPP. A strong safety culture, also demonstrated, has contributed greatly to improving performance at Daya Bay

2001-12-01

325

NHTSA Contact Information | National Highway Traffic Safety Administra...  

Science.gov (United States)

Skip to Main Content Skip to Main Navigation National Highway Traffic Safety Administration Accessible menu--Sitemap Driving Safety Aggressive Driving Bicycles Child Safety...

2011-09-24

327

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area either from the CRPC or ...

2004-02-01

328

Achievements and Perspectives of the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management  

International Nuclear Information System (INIS)

The Joint Convention on the Safety of Spent Fuel management and on the Safety of Radioactive Waste Management is the first legal instrument to directly address the safety of spent fuel and radioactive waste management on a global scale. The Joint Convention entered into force in 2001. This paper describes its process and its main achievements to date. The perspectives to establish of a Global Waste Safety Regime based on the Joint Convention are also discussed. (authors)

329

Uranium-233 waste definition: Disposal options, safeguards, criticality control, and arms control  

Energy Technology Data Exchange (ETDEWEB)

The US investigated the use of {sup 233}U for weapons, reactors, and other purposes from the 1950s into the 1970s. Based on the results of these investigations, it was decided not to use {sup 233}U on a large scale. Most of the {sup 233}U-containing materials were placed in long-term storage. At the end of the cold war, the US initiated, as part of its arms control policies, a disposition program for excess fissile materials. Other programs were accelerated for disposal of radioactive wastes placed in storage during the cold war. Last, potential safety issues were identified related to the storage of some {sup 233}U-containing materials. Because of these changes, significant activities associated with {sup 233}U-containing materials are expected. This report is one of a series of reports to provide the technical bases for future decisions on how to manage this material. A basis for defining when {sup 233}U-containing materials can be managed as waste and when they ...

1998-07-07

330

TRIGA reactor spent fuel pool under severe earthquake conditions  

International Nuclear Information System (INIS)

Supplemental criticality safety analysis of a pool type storage for TRIGA spent fuel at 'Jozef Stefan' Institute in Ljubljana, Slovenia, is presented. Previous results (Ravnik, M, Glumac, B., 1996) have shown that subcriticality is not guaranteed for some postulated accidents. To mitigate this deficiency, a study was made about replacing a certain number of fuel elements in the rack with absorber rods (Glumac, B., Ravnik, M., Logar, M., 1997) to lower the supercriticality probability, when the pitch is decreased to contact (as a consequence of a severe earthquake) in a square arrangement. The criticality analysis for the hexagonal contact pitch is presented in this paper, following the same scenario as outlined above. The Monte Carlo computer code MCNP4B with ENDF-B/VI library and detailed three dimensional geometry was used. First, the analysis about the influence of the number of triangular fuel piles on the bottom that ...

1998-07-01

331

Criticality calculations of the fixed bed nuclear reactor  

Energy Technology Data Exchange (ETDEWEB)

The Fixed Bed Nuclear Reactor (FBNR) is a small 40 MWe reactor based on the Pressurized Water Reactor (PWR) technology. FBNR is an integrated primary circuit and simple in design. It has the characteristics of being small, modular, proliferation resistant, inherently safe and passively cooled reactor with reduced adverse environmental impact. It utilizes the fuel designed for high temperature reactors operating in a relatively low temperature of PWR environment The 15 mm diameter spherical fuel elements are made of TRISO type microspheres embedded in graphite and cladded by SiC. The coolant flow transfers them from the fuel chamber into the core and become fixed forming a suspended core. Any accident signal will cut off the power to the coolant pump causing a stop in the flow. This results in making the fuel elements fall out of the reactor core by the force of gravity and return into the fuel chamber where they are passively cooled under subcritical condition. Therefore, the ...

2007-07-01

332

Addressing the Challenges Special Needs Students Face when Transitioning from the Classroom to the Workplace  

Science.gov (United States)

One of the biggest fears and challenges a parent of a child with special needs faces is navigating the post-22 landscape. When a child hits the age of 22, the Department of Elementary and Secondary Education (DESE) is no longer required to provide daily services and support. Whatever the abilities, or disabilities, of a child, every parent has the same concerns about how their child will productively fill their days and live as independently as possible without the safety net of the DESE. One of the transition paths most frequented is entering the workforce. Public and private schools alike work to teach their students the basic skills they need to work. In fact, the national Individuals with Disabilities Education Act (IDEA) states that students must have a transition plan in formulation by the age of 16. This article describes the vocational program developed by the League School of Greater Boston which specifically addresses the challenges students, their ...

2010-10-01

333

Safety of pipe whip restraints  

International Nuclear Information System (INIS)

Pipe whip restraints are used in nuclear power plants in order to limit the consequences of ruptured pipe whip effects and are thus an important part of the plant safety concept. The design of these devices is based on the choice of adequate construction and computational analysis supported by experimental investigation. Pipe whip restraints should, by means of deforming components, be able to absorb the energy of a ruptured pipe accelerated by the fluid reaction force. Since the elastic deformation of the restraint material is not sufficient for this purpose, or would result in excessive anchor loads, pipe whip restraints must generally be designed to work in the plastic range. Two types of restraints are presented in this paper, including the description of their mode of operation, design and computation. A comparison and critical evaluation of the calculation methods presently available are also given. The range of methods covers those ...

334

Quantification of radionuclide transfer in terrestrial and freshwater environments for radiological assessments  

International Nuclear Information System (INIS)

For more than thirty years, the IAEA has published a set of documents aimed at the limitation of the radiation exposure of the population from various nuclear activities. In particular, in 1994 the IAEA published Technical Reports Series No. 364, Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Temperate Environments. Over the years, it has proved to be a valuable reference for radioecologists, modellers and authorities in Member States, and has been quoted in numerous impact assessments. Technical Reports Series No. 364 was based on a review of available data up to the end of 1992. However, a number of high quality critical reviews have been produced in recent years for some of the transfer parameter values which merit consideration. Thus, it was assumed that there is sufficient new information available to warrant reconsideration of a significant proportion of the values given in Technical Reports Series No. 364 and to initiate an ...

1993-04-05

335

Mitigating aging in CANDU plants  

Energy Technology Data Exchange (ETDEWEB)

Aging degradation is a phenomenon we all experience throughout life, both on a personal basis and in business. Many industries have been successful in postponing the inevitable impact on their related systems and components through programs to maintain long-term reliability, maintainability and safety. However, this has not always been the case for nuclear power. While all power plants are experiencing the world trend of increasing operating costs with age, few (if any) have been able to fully define the parameters that solve the aging equation, particularly in relation to major components. Inspection and preventive maintenance have not been effective in predicting life-limiting degradation and failure. In CANDU nuclear plants, utilities are taking a comprehensive approach in dealing with the aging problem. Programs have been established to identify the current condition and degradation mechanisms of critical components, the failure of which ...

1995-07-01

336

HT technology -- All-metal sealing answers safety and environmental concerns  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the tree, to maximize dropped object protection. ...

1995-12-31

337

Losing weight to save lives: A review of the role of automobile weight and size in traffic fatalities  

Energy Technology Data Exchange (ETDEWEB)

Critics of higher fuel economy standards for vehicles have long argued that improving vehicle fuel economy will require reducing vehicle weight, and that would result in an increase in the number of fatalities from vehicle crashes. Several researchers have estimated that an across-the-board reduction of vehicle weight would reduce passenger safety (Evans 1991; Kahane 1997; U.S. GAO 1994). However, little research has been done on the relationship of vehicle size and fatality rates, independent of weight (see, however, Joksch, Massie, and Pichler 1998). In this report we review previous analyses of the relationship of vehicle weight and safety. We do this to study the opportunities to improve fuel economy in a more sophisticated way than across-the-board mass reduction. The aim is to explore improvements in traffic safety by making selected vehicle groups lighter, and retaining or enlarging selected ...

2001-07-01

338

Requirements for modeling and simulation of space RSTA assets  

Science.gov (United States)

The Department of Defense (DoD) has long depended on military support functions enabled by space reconnaissance, surveillance, and target acquisition (RSTA) assets. Future generation satellite capabilities will further push technologies in space - if the right technologies are deployed in the right numbers and with the right payloads. Modeling and simulation play major parts in developing and deploying such assets: 1) system and operational requirements determination, and 2) assessment of military utility of such assets. Each area is critical in a system"s life cycle. Requirements determination cuts across the issues of doctrine, organizations, training, materiel, leader development, personnel, and facilities (DOTMLPF). Military utility assessments are necessary to explore and quantify the military worth/benefit of space RSTA assets to operational commanders. Each of these areas requires relevant modeling/simulation tools which span the ...

2004-09-01

339

Novel Binders and Methods for Agglomeration of Ore  

Energy Technology Data Exchange (ETDEWEB)

Many metal extraction operations, such as leaching of copper, leaching of precious metals, and reduction of metal oxides to metal in high-temperature furnaces, require agglomeration of ore to ensure that reactive liquids or gases are evenly distributed throughout the ore being processed. Agglomeration of ore into coarse, porous masses achieves this even distribution of fluids by preventing fine particles from migrating and clogging the spaces and channels between the larger ore particles. Binders are critically necessary to produce agglomerates that will not break down during processing. However, for many important metal extraction processes there are no binders known that will work satisfactorily at a reasonable cost. A primary example of this is copper heap leaching, where there are no binders currently encountered in this acidic environment process. As a result, operators of many facilities see a large loss of process efficiency due to their ...

2006-03-31

340

Low-Cost, Robust, Threat-Aware Wireless Sensor Network for Assuring the Nation's Energy Infrastructure  

Energy Technology Data Exchange (ETDEWEB)

Eaton, in partnership with Oak Ridge National Laboratory and the Electric Power Research Institute (EPRI) has completed a project that applies a combination of wireless sensor network (WSN) technology, anticipatory theory, and a near-term value proposition based on diagnostics and process uptime to ensure the security and reliability of critical electrical power infrastructure. Representatives of several Eaton business units have been engaged to ensure a viable commercialization plan. Tennessee Valley Authority (TVA), American Electric Power (AEP), PEPCO, and Commonwealth Edison were recruited as partners to confirm and refine the requirements definition from the perspective of the utilities that actually operate the facilities to be protected. Those utilities have cooperated with on-site field tests as the project proceeds. Accomplishments of this project included: (1) the design, modeling, and simulation of the anticipatory wireless sensor ...

2007-03-31

341

Evaluation of a stack: A concrete chimney with brick liner  

Energy Technology Data Exchange (ETDEWEB)

A 200 ft. tall stack, consisting of a concrete chimney with an independent acid proof brick liner built in the 1950`s, serving the Separations facility at the Savannah River Site (SRS), was evaluated for the performance category 3 (PC3) level of Natural Phenomena Hazards (NPH) effects. The inelastic energy absorption capacity of the concrete chimney was considered in the evaluation of the earthquake resistance, in particular, to compute the F{sub {mu}} factor. The calculated value of F{sub {mu}} exceeded 3.0, while the seismic demand for the PC3 level, using an F{sub {mu}} value of 1.5, was found to be less than the capacity of the concrete chimney. The capacity formulation of ACI 307 was modified to incorporate the effect of an after design opening on the tension side. There are considerable uncertainties in determining the earthquake resistance of the independent brick liner. The critical liner section, located at the bottom of the breeching ...

1995-12-31

342

Analysis of High-Moderation MOX Core MISTRAL-3 with SRAC and MVP  

International Nuclear Information System (INIS)

To obtain reactor physics parameters for high-moderation mixed-oxide (MOX) cores, Nuclear Power Engineering Corporation (NPEC), the French Atomic Commission (CEA), and their industrial partners have conducted a MOX core physics experimental program called MISTRAL with the EOLE critical facility of the Cadarache research center. This program consists of four high-moderation cores and was successfully completed in July 2000. This paper describes the analysis results of MISTRAL-3 that is a homogeneous full MOX cylindrical core (H/HM = 6.2) with an 80-cm height and a 59-cm diameter consisting of 1388 standard pressurized water reactor-type MOX fuel rods of 7.0 wt% plutonium-enrichment in a square pitch of 1.39 cm. NPEC has been analyzing the experimental results by using the SRAC and MVP code systems. SRAC and MVP calculate the nuclear core characteristics correctly for the high-moderation MOX core MISTRAL-3. No apparent trend with the moderation ...

2001-06-17

343

White Rose Development Plan amendment South White Rose extension tie back  

Energy Technology Data Exchange (ETDEWEB)

In January 2001, Husky Oil Operations Limited (Husky), in joint-venture with Petro-Canada submitted a Development Application (DA) to the Canada-Newfoundland and Labrador Offshore Petroleum Board (C-NLOPB) for the White Rose Development. This DA was prepared following the Canada-Newfoundland Atlantic Accord Implementation Act and the Canada-Newfoundland and Labrador Atlantic Accord Implementation Newfoundland and Labrador Act. In December 2001, the C-NLOPB approved the White Rose DA. This document outlined a proposed amendment to the original Development Plan involving an expansion of its White Rose Development in the Jeanne d'Arc Basin on the Grand Bank. The expansion will consist of a subsea tie-back to the Floating Production, Storage and Offloading (FPSO) vessel through the existing Southern Glory Hole (SGH) and utilizing a new glory hole constructed approximately 4 km south of the SGH. The document presented an overview of the development; geology, geophysics and ...

2006-09-15

344

Strategic principles workshops: Discussion drafts and workshop notes  

Energy Technology Data Exchange (ETDEWEB)

The Office of Civilian Radioactive Waste-Management in the Department of Energy (DOE) is responsible for disposing of this nation`s spent fuel and high-level radioactive waste in a manner that protects the health and safety of the public and the quality of the environment. Although embodied in the Federal repository program that began with studies in the late 1950s, this mission was explicitly established by the Nuclear Waste Policy Act of 1982 and reaffirmed by the Nuclear Waste Policy Amendments Act of 1987. To fulfill our mission, we are developing a waste management system consisting of a geologic repository for permanent disposal deep beneath the surface of the earth, a facility for monitored retrievable storage, and a system for transporting the waste. This discussion draft was developed to help involve parties affected by or interested in the waste-management program in the formulation of the basic principles on which the program will be ...

1991-09-01

345

Remote handling equipment to robotics - Development within BNFL  

International Nuclear Information System (INIS)

There are two major distinct activities involved with reprocessing of nuclear fuel. They are: a) Mechanical handling of the fuel in the head end plants; and b) chemical dissolution and separation of unused fuel, useful by-products and waste products. Plants and facilities associated with the former include significant remote handling equipment that is designed for handling of fuel for normal production processes. These equipment are selected and designed to meet the design throughput of the plant taking into consideration ease of their operation and maintenance in conjunction with statutory regulations on safety and operator dose uptake. Nevertheless, during the life of the plant, there are instances when special equipment is called for to access part of the plant and undertake tasks such as inspection, maintenance and modification to improve the existing process. BNFL has much experience in the design and application of remote handling ...

1995-11-01

346

Proceedings of the 58. annual technical meeting of the Petroleum Society of CIM : CIPC 2007 : Because technology changes everything  

International Nuclear Information System (INIS)

This conference and trade show provided a forum to present new, emerging and existing technologies that will play a key role in ensuring that hydrocarbon exploitation occurs in a sustainable manner, where costs and resource recovery are optimized while minimizing environmental impacts. The challenge of developing maturing basins, frontier lands and unconventional resources was discussed. In particular, the application of thermal recovery methods such as steam assisted gravity drainage (SAGD) for the in-situ recovery of heavy oils and bitumens was reviewed and compared with the performance of alternative enhanced energy recovery technologies such as vapor extraction (VAPEX). The conference was attended by local and international participants in the petroleum sector, including managers, engineers, technologists, geologists, and other petroleum industry specialists. The conference featured 132 presentations addressing topics such as improved recovery of conventional oil and gas; heavy oil ...

2007-06-12

347

Nuclear power and sustainable development  

International Nuclear Information System (INIS)

In Romania, the nuclear power is an element of sustainable development, being competitive, efficient and viable in the market economy. Fuel supply is ensured as nuclear fuel is manufactured in the country out of local uranium resources available in Romania. As for the environmental protection, it is known that, unlike the thermal power plants, the nuclear power plants do not release sulfur and nitrogen oxides, carbon dioxide and do not generate slag and ashes. The operation of nuclear power units does not release pollutants and, accordingly, these stations can contribute to the limitation and the abatement of environmental pollution. After seven years of Cernavoda NPP Unit 1 operation, a facility for storing low and medium level nuclear fuel wastes was built at the plant site as well as an intermediate dry storage for spent nuclear fuel whose first modules were commissioned in July 2003. They shall provide safe storage conditions for nuclear fuel wastes for many ...

2003-07-01

348

International symposium on nuclear security. Book of extended synopses  

International Nuclear Information System (INIS)

The International Symposium on Nuclear Security took place within a context of international acknowledgement that the threat of nuclear terrorism required dedicated action by the international community, States, industry and others. The Symposium dealt with those issues involved in protecting nuclear and other radioactive material from criminals. It also took place against a backdrop of renewed interest in nuclear technology: increased use of nuclear power, and increased use of radioactive isotopes in medicine and in industry. These are welcome developments, since nuclear energy and technology can indeed contribute to the technological and economic welfare of many countries, without compromising public health or the environment. In this context, security measures should not impede State programmes for peaceful use of nuclear technology. The symposium dealt with (1) the threat of nuclear terrorism and of other nuclear-related criminal acts; (2) international response and cooperation; ...

2003-11-05

349

Innovative coke oven gas cleaning system for retrofit applications. Volume 1, Public design report  

Energy Technology Data Exchange (ETDEWEB)

This Public Design Report provides, in a single document, available nonproprietary design -information for the ``Innovative Coke Oven Gas Cleaning System for Retrofit Applications`` Demonstration Project at Bethlehem Steel Corporation`s Sparrows Point, Maryland coke oven by-product facilities. This project demonstrates, for the first time in the United States, the feasibility of integrating four commercially available technologies (processes) for cleaning coke oven gas. The four technologies are: Secondary Gas Cooling, Hydrogen Sulfide and Ammonia Removal, Hydrogen Sulfide and Ammonia Recovery, and Ammonia Destruction and Sulfur Recovery. In addition to the design aspects, the history of the project and the role of the US Department of,Energy are briefly discussed. Actual plant capital and projected operating costs are also presented. An overview of the integration (retrofit) of the processes into the existing plant is presented and is followed by detailed ...

1994-05-24

350

Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone  

International Nuclear Information System (INIS)

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher application ranges for the heat-shrinkable ...

2005-06-15

351

Increase in the number of distributed power generation installations in electricity distribution grids - Project findings; Zunahme der dezentralen Energieerzeugungsanlagen in elektrischen Verteilnetzen: Erkenntnisse aus dem Projekt  

Energy Technology Data Exchange (ETDEWEB)

This is the eighth part of a ten-part final report for the Swiss Federal Office of Energy (SFOE) on a project that looked into potential problems relating to the Swiss electricity distribution grid with respect to the increasing number of distributed power generation facilities being put into service. The identification of special conditions for the grid's operation and future development that take increasing decentralised power production into account are discussed. The results of the project activities encompass the analysis and evaluation of various problem areas associated with planning and management of the grid during normal operation and periods of malfunction, as well as required modifications to safety systems and grid configurations. This seventh appendix to the main report summarises and discusses the knowledge gained during the project and attempts to provide answers to various questions posed by the use of distributed ...

2003-07-01

352

Ice engineering advances : their impact on development concepts  

Energy Technology Data Exchange (ETDEWEB)

The Hebron offshore drilling project in Atlantic Canada was discontinued in 2002 due to economic challenges. Chevron-Texaco has conducted small-scale studies to find ways to improve the project's viability. One of the main challenges facing this offshore drilling project is the issue of iceberg scour and its effect on seafloor equipment. This paper demonstrates how advances in ice engineering have resulted in new and cost-effective development concepts for: central gravity base structures; wellhead gravity base structures; floating production, storage and offloading (FPSO) subsea facilities; and, long subsea tieback and trench optimization. New studies have provided a better understanding of ice contact pressures, drift velocities, iceberg management and interaction processes. New designs for gravity base structures can reduce wave loads. The selection of a new development concept is determined by economic viability, capital cost, operability, technical ...

2004-07-01

353

Highlights of design and construction of Sendai Nuclear Power Station Unit No.2  

International Nuclear Information System (INIS)

As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, improved steam generators, a reactor vessel cover of one-body type, ...

1985-01-01

354

GENERAL REQUIREMENTS FOR SIMULATION MODELS IN WASTE MANAGEMENT  

Science.gov (United States)

Most waste management activities are decided upon and carried out in a public or semi-public arena, typically involving the waste management organization, one or more regulators, and often other stakeholders and members of the public. In these environments, simulation modeling can be a powerful tool in reaching a consensus on the best path forward, but only if the models that are developed are understood and accepted by all of the parties involved. These requirements for understanding and acceptance of the models constrain the appropriate software and model development procedures that are employed. This paper discusses requirements for both simulation software and for the models that are developed using the software. Requirements for the software include transparency, accessibility, flexibility, extensibility, quality assurance, ability to do discrete and/or continuous simulation, and efficiency. Requirements for the models that are developed include traceability, transparency, ...

2003-02-27

355

Fluid mixing in reactor containment  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Hydrogen release and distribution in nuclear power plant containment is an important safety issue. Selection of a proper turbulence model is important for accurate estimation of the mixing process. The selection of turbulence model is dictated by the best compromise between accuracy and computational efforts. For this, three different turbulence models, viz. Standard k-{epsilon}, RNG k-{epsilon} and Reynolds Stress Model, based on Reynolds averaged Navier Stokes equations (RANS) approach, were used. The computations were done using the CFD code FLUENT, which is based on the control volume methodology. The computational results were compared with the experimental results of HYMIS test facility, where helium was used to simulate hydrogen. The processes of helium plume rise, multiple plume merging, distribution and mixing were studied. Based on these computations, a simple analytical/empirical zone based model was ...

2005-07-01

356

Fluid mixing in reactor containment  

International Nuclear Information System (INIS)

Full text of publication follows: Hydrogen release and distribution in nuclear power plant containment is an important safety issue. Selection of a proper turbulence model is important for accurate estimation of the mixing process. The selection of turbulence model is dictated by the best compromise between accuracy and computational efforts. For this, three different turbulence models, viz. Standard k-#epsilon#, RNG k-#epsilon# and Reynolds Stress Model, based on Reynolds averaged Navier Stokes equations (RANS) approach, were used. The computations were done using the CFD code FLUENT, which is based on the control volume methodology. The computational results were compared with the experimental results of HYMIS test facility, where helium was used to simulate hydrogen. The processes of helium plume rise, multiple plume merging, distribution and mixing were studied. Based on these computations, a simple analytical/empirical zone based model was ...

2005-10-02

357

Evaluation of Core Bypass Flow in the Prismatic VHTR with a Multi-block Experiment  

International Nuclear Information System (INIS)

The core of Prismatic Modular Reactor (PMR) consists of assemblies of hexagonal graphite fuel and reflector elements. The core bypass flow of Very High Temperature Reactor (VHTR) is defined as the core flow that does not pass through the coolant channels but passes through the bypass gap between fuel elements. The increase in bypass flow makes the decrease in effective coolant flow. Since the core bypass flow has a negative impact on safety and efficiency of VHTR, core bypass phenomena have to be investigated to improve the core thermal margin of VHTR. For this purpose, the international project, I-NERI project, has been carried out since 2008. I-NERI project is collaborative project that KAERI and SNU of Korea side and INL, ANL and TAMU of U.S side are involved. In order to evaluate the core bypass flow, the multicolumn and multi-layer experimental facility is designed by SNU. In this experiment, the effect of cross-flow and local variation of ...

2010-10-01

358

Environmental Restoration Remedial Action quality assurance requirements document  

International Nuclear Information System (INIS)

This document defines the quality assurance requirements for the US Department of Energy-Richland Operations Office Environmental Restoration Remedial Action program at the Hanford Site. The Environmental Restoration Remedial Action program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency. This document combines quality assurance requirements from various source documents into one set of requirements for use by the US Department of Energy-Richland Operations Office and other Environmental Restoration Remedial Action program participants. This document will serve as the basis for developing Quality Assurance Program Plans and implementing procedures by the participants. The requirements of this document will be applied to activities affecting quality, using a graded approach based on ...

359

Environmental Restoration Program quality assurance system requirements for the Hanford Site  

International Nuclear Information System (INIS)

This document defines the quality assurance program requirements for the US Department of Energy, Richland Field Office, Environmental Restoration program at the Hanford Site. This document integrates quality assurance requirements from US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order, and applicable industry standards into a single source document for the development of quality assurance programs applicable to the Environmental Restoration program items and activities. This document has been configured into three parts and fifteen criteria to provide user organizations with a workable document that best facilitates line operations. When developing individual user organization quality assurance programs, the document configuration provides each organization with the Flexibility to incorporate only those parts and criteria that are applicable to their individual scope of work as it is associated with the Environmental ...

360

Comparison of the SASSYS/SAS4A radial core expansion reactivity feedback model and the empirical correlation for the FFTF  

International Nuclear Information System (INIS)

The present emphasis on inherent safety for liquid-metal reactor designs has resulted in a need to represent the various reactivity feedback mechanisms as accurately as possible. The dominant negative reactivity feedback has been found to result from radial expansion of the core for most postulated anticipated transient without scram events. For this reasons, a more detailed model for calculating the reactivity feedback from radial core expansion, including subassembly bowing has been recently developed for use with the SASSYS/SAS4A code system. The purpose of this summary is to present an extension to the model so that it is more suitable for handling a core restraint design as used in the Fast Flux Test Facility (FFTF), and to compare the SASSYS/SAS4A results using this model to the empirical correlation presently being used to account for radial core expansion reactivity feedback in the FFTF.

1987-11-15

361

CFD code fluent turbulence models application. Ansaldo's prototype modeling  

International Nuclear Information System (INIS)

Among others, one of the main activities in the Nuclear Engineering and Fluid Mechanics Department of the Engineering School in Bilbao, is the study of liquid metals behavior. And for this purpose the CFD code FLUENT is being used. Currently, the code is being applied to the use of Lead-Bismuth eutectic (LBE) as the coolant of an accelerator driven system (ADS) and also as the target for a neutron source. In this paper, ANSALDO's Energy Amplifier Demonstration Facility is simulated, paying attention only on the coolant. As it will be later explained, natural convection is a very important issue, because the philosophy for safety systems in nuclear devices tends to consider passive technologies. The purpose is to avoid electrical machines like pumps, so the core should remain coolable, even if there is a blackout. To get this natural circulation, heat transfer plays a main role, and as turbulence enhances the heat transfer, it is important to ...

2001-12-04

362

Assessment of the impacts of spent fuel disassembly alternatives on the Nuclear Waste Isolation System  

International Nuclear Information System (INIS)

The objective of this report was to evaluate four possible alternative methods of preparing and packaging spent fuel assemblies for geologic disposal against the Reference Process of unmodified spent fuel. The four alternative processes were: (1) End fitting removal, (2) Fission gas venting and resealing, (3) Fuel bundle disassembly and close packing of fuel pins, and (4) Fuel shearing and immobilization. Systems analysis was used to develop a basis of comparison of the alternatives. Conceptual processes and facility layouts were devised for each of the alternatives, based on technology deemed feasible for the purpose. Assessments were made of 15 principal attributes from the technical, operational, safety/risk, and economic considerations related to each of the alternatives, including both the surface packaging and underground repository operations. Specific attributes of the alternative processes were evaluated by assigning a number for each ...

363

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts ...

2009-07-15

364

Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors  

International Nuclear Information System (INIS)

Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also vary. In order to perform controlled tests ...

365

Present status of study on reduced-moderation water reactors  

Energy Technology Data Exchange (ETDEWEB)

The Reduced-Moderation Water Reactor (RMWR) is a next generation water-cooled reactor, based on the experienced light water reactor (LWR) technology, aiming at effective utilization of uranium resources, high burn-up and long operation cycle and plutonium multiple recycling. These characteristics can be achieved by the high conversion ratio from {sup 238}U to {sup 239}Pu resulted from the higher neutron energy spectrum in comparison to conventional LWRs. Considering the extension of LWR utilization, Japan Atomic Energy Research Institute (JAERI) started the research on it in 1997 and then started a collaboration in the conceptual design study with the Japan Atomic Power Company (JAPC) in 1998, under technical cooperation with three Japanese reactor vendors. In the core design study of the RMWR, several basic core designs with the high conversion ratio more than 1 and the negative void reactivity coefficient have been proposed, and then, subsequent investigation on the effects of ...

2001-09-01

366

Enterprise energy management : Part 1  

Energy Technology Data Exchange (ETDEWEB)

The needs of large industrial, commercial, and institutional energy consumers are more closely connected with the needs of power utilities and energy services companies, a result of the evolving global energy environment. Consumer choice, competition amongst energy suppliers, and increased demand are brought about in some regions by deregulation. Increasingly, large energy consumers expect high levels of quality and reliability from the energy delivered. As a result, management of the cost and the quality of the energy product and the energy assets that produce, deliver, control and consume it requires different strategies. Three major challenges must be overcome: (1) requirement to support economic and efficient delivery, purchasing and use of energy, (2) requirement to guarantee higher levels of power quality and reliability, and (3) requirement to supply the growing demand for energy while establishing a market-based pricing system. The solution is the enterprise energy management ...

2001-09-01

367

Routine environmental audit of the Y-12 Plant, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of the routine environmental audit of the Oak Ridge Y-12 Plant (Y-12 Plant), Anderson County, Tennessee. During this audit, the activities conducted by the audit team included reviews of internal documents and reports from previous audits and assessments; interviews with U.S. Department of Energy (DOE), State of Tennessee regulatory, and contractor personnel; and inspections and observations of selected facilities and operations. The onsite portion of the audit was conducted August 22-September 2, 1994, by the DOE Office of Environmental Audit (EH-24), located within the Office of Environment, Safety and Health (EH). DOE 5482.1 B, {open_quotes}Environment, Safety, and Health Appraisal Program,{close_quotes} establishes the mission of EH-24 to provide comprehensive, independent oversight of DOE environmental programs on behalf of the Secretary of Energy. The ultimate goal of EH-24 is ...

1994-09-01

368

FFTF operational results: startup to 100 MWd/kg  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; ...

369

Evaluation of the suitability of the WIPP site  

Energy Technology Data Exchange (ETDEWEB)

Determination of the suitability of the site for WIPP is only the first major phase in the evaluation of the radiological impact of the repository on the public health and safety. The Environmental Evaluation Group (EEG) will continue to independently review the design of the facility, the operational procedures, the criteria for packaging and shipment of the waste, the plans, procedures and results of the WIPP experiments, emergency preparedness, adherence to EPA and pertinent NRC regulations, and other important features of the project. EEG has concluded from existing evidence that the Los Medanos site for the WIPP project has been characterized in sufficient detail to warrant confidence in the validation of the site for the permanent emplacement of approximately 6 million cubic feet of defense transuranic waste. This conclusion is based on the assumption that the maximum surface dose rate for the unshielded remote-handled transuranic waste ...

1983-05-01

370

ADVANCED CUTTINGS TRANSPORT STUDY  

Energy Technology Data Exchange (ETDEWEB)

This is the third quarterly progress report for Year 3 of the ACTS Project. It includes a review of progress made in: (1) Flow Loop construction and development and (2) research tasks during the period of time between Jan. 1, 2002 and Mar. 31, 2002. This report presents a review of progress on the following specific tasks: (a) Design and development of an Advanced Cuttings Transport Facility (Task 3: Addition of a Cuttings Injection/Separation System), (b) Research project (Task 6): ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)'', (c) Research project (Task 9b): ''Study of Foam Flow Behavior Under EPET Conditions'', (d) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions'', (e) Research on three instrumentation tasks to measure: Cuttings ...

2002-04-30

371

Operational reactor physics analysis codes (ORPAC)  

International Nuclear Information System (INIS)

Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper ...

372

X-ray ablation measurements and modeling for ICF applications  

Energy Technology Data Exchange (ETDEWEB)

X-ray ablation of material from the first wall and other components of an ICF (Inertial Confinement Fusion) chamber is a major threat to the laser final optics. Material condensing on these optics after a shot may cause damage with subsequent laser shots. To ensure the successful operation of the ICF facility, removal rates must be predicted accurately. The goal for this dissertation is to develop an experimentally validated x-ray response model, with particular application to the National Ignition Facility (NIF). Accurate knowledge of the x-ray and debris emissions from ICF targets is a critical first step in the process of predicting the performance of the target chamber system. A number of 1-D numerical simulations of NIF targets have been run to characterize target output in terms of energy, angular distribution, spectrum, and pulse shape. Scaling of output characteristics with variations of both target yield and ...

1996-09-01

373

Past and future upgrades of the gyrotron high voltage cathode power supplies at the Forschungszentrum Karlsruhe  

Energy Technology Data Exchange (ETDEWEB)

The high voltage/high power DC-cathode power supply for the Gyrotron Test Facility at the Forschungszentrum in Karlsruhe consists of a 12-pulse thyristor star-point-controller, a 130 kV capacitor-bank followed by a tetrode regulator. Originally designed for 80 kV/30 A CW (continous-wave) operation, its operating regime has been extended in line with gyrotron development to pulses of 65 kV/45 A/3 min and more recently to 65 kV/80 A/10 s without any changes to the main load bearing components (thyristors, transformers or power tetrode). This allows testing of gyrotrons in the 0.5 MW (CW), 1 MW (3 min) and 2 MW (10 s) output power range. The paper describes the system, its operation and some critical aspects of the last upgrade, such as the issue of harmonics in the 20 kV distribution mains-grid, the dynamic response of the thyristor-controller and the avoidance of microwave parasitic oscillations in the high power tetrode (a CQK-200-4, developed ...

2009-06-15

374

Engineering Technology Reports, Volume 2: Technology Base FY00  

Energy Technology Data Exchange (ETDEWEB)

In FY-2000, Engineering at Lawrence Livermore National Laboratory faced significant pressures to meet critical project milestones, and immediate demands to facilitate the reassignment of employees as the National Ignition Facility (the 600-TW laser facility being designed and built at Livermore, and one of the largest R&D construction projects in the world) was in the process of re-baselining its plan while executing full-speed its technology development efforts. This drive for change occurred as an unprecedented level of management and program changes were occurring within LLNL. I am pleased to report that we met many key milestones and achieved numerous technological breakthroughs. This report summarizes our efforts to perform feasibility and reduce-to-practice studies, demonstrations, and/or techniques--as structured through our technology centers. Whether using computational engineering to predict how giant ...

2001-10-03

375

Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test  

Energy Technology Data Exchange (ETDEWEB)

The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring ...

1999-03-01

376

Mittelplate pipeline: planning and executing of a challenging project in an environmentally sensitive area; Pipelineanbindung des Erdoelfeldes Mittelplate: Hintergruende und Chronologie eines komplexen Projektes in einem oekologisch sensiblen Umfeld  

Energy Technology Data Exchange (ETDEWEB)

The Mittelplate oilfield is located in the Waddensea tidelands 8 km off the north sea coast and represents Germany's largest oilfield. Since Mittelplate oil production has started in 1987, RWE Dea AG being the operator in a 50/50 joint venture with Wintershall AG, has continually implemented and improved the sophisticated technology required to exploit natural resources by using safe and environmentally compatible means in the sensitive tideland environment of Mittelplate. Besides the sucessful offshore operations from the man-made Mittelplate Drilling and Production Island, further onshore development has started in 2000 by producing from high-tech ERD wells drilled from onshore locations. The offshore oil production had been transported so far by specially designed tug and tow barges and had been restricted by weather and tide. To overcome this bottleneck and to enable an accelerated offshore drilling and production program a pipeline link between Mittelplate Island and ...

2006-04-15

377

Low-activity waste envelope definitions for the TWRS Privatization Phase I Request For Proposal  

Energy Technology Data Exchange (ETDEWEB)

Radioactive waste has been stored in large underground storage tanks at the Hanford Site since 1944. Approximately 212 million liters of waste containing approximately 240,000 metric tons of processed chemicals and 177 mega-curies of radionuclides are now stored in 177 tanks. These caustic wastes are in the form of liquids, slurries, saltcakes, and sludge. In 1991, the Tank Waste Remediation System (TWRS) Program was established to manage, retrieve, treat, immobilize, and dispose of these wastes in a safe, environmentally sound, and cost-effective manner. The Department of Energy (DOE) has believes that it is feasible to privatize portions of the TWRS Program. Under the privatization strategy embodied in the Request for Proposal (RFP), DOE will purchase services from a contractor-owned, contractor-operated facility under a fixed-price contract. Phase I of the TWRS privatization strategy is a proof-of-concept/commercial demonstration-scale effort. The objectives of ...

1996-11-01

378

Environmental Survey preliminary report, Idaho National Engineering Laboratory, Idaho Falls, Idaho and Component Development and Integration Facility, Butte, Montana  

Energy Technology Data Exchange (ETDEWEB)

This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, ...

1988-09-01

379

Differential rod worth profile affected by axial blankets in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The central feature of the Fast Flux Test Facility (FFTF) is the fast test reactor (FTR), which is a liquid-sodium-cooled fast reactor providing high fast-neutron flux for irradiation testing of fuels and materials. The FTR also provides a means to develop breeder reactor core components and to gain reactor systems operating experience for future liquid-metal fast breeder reactors (LMFBRs). In the FTR core, there are 82 incore positions (within rows 1 through 6) available for driver fuel assemblies and/or test assemblies. In addition, there are three safety rods and six control rods located in rows 3 and 5, respectively, in the three symmetric core sectors. The FFTF has been successfully and continuously operated for more than 11 reactor cycles. For the first 8 cycles, the core loadings were composed of the mixed-oxide driver fuel assemblies and some test assemblies. These assemblies have an active core section of 91.5 cm with 15.2-cm upper and ...

1990-06-10

380

Assessment of gas flammability in transuranic waste container  

Energy Technology Data Exchange (ETDEWEB)

The Safety Analysis Report for the TRUPACT-II Shipping Package [Transuranic Package Transporter-II (TRUPACT-II) SARP] set limits for gas generation rates, wattage limits, and flammable volatile organic compound (VOC) concentrations in transuranic (TRU) waste containers that would be shipped to the Waste Isolation Pilot Plant (WIPP). Based on existing headspace gas data for drums stored at the Idaho National Engineering Laboratory (INEL) and the Rocky Flats Environmental Technology Site (RFETS), over 30 percent of the contact-handled TRU waste drums contain flammable VOC concentrations greater than the limit. Additional requirements may be imposed for emplacement of waste in the WIPP facility. The conditional no-migration determination (NMD) for the test phase of the facility required that flame tests be performed if significant levels of flammable VOCs were present in TRU waste containers. This paper describes an approach ...

1995-12-01

381

A.C.R.O. activity report 2001; A.C.R.O. rapport d'activite 2001  

Energy Technology Data Exchange (ETDEWEB)

As regards the environmental protection, the A.C.R.O. maintained in 2001 its programs of surveillance around the main western nuclear installations of France. The radioecological surveillance of the site of Cogema La-Hague for the dismantling of the former pipe of release in sea was one of the key points of this action environmental surveillance. The two accidents of atmospheric release in may and october 2001 at Cogema La Hague have shown the interest of an association as A.C.R.O.. It is thank to the measure, by our laboratory, of repercussions on environment of these incidents that it has been possible to bring to light a dysfunction of the measurement system of the gaseous effluents released by the facility operator. To improve the public information, A.C.R.O. concerns its main efforts on the development of the consumer technical information available on-line via its web site and in its regular publication 'the nuclear chronicle'. Besides, the ...

2001-07-01

383

PPT Slide  

Indian Academy of Sciences (India)

central server with search facility involving all partner journals ...

390

Neutron cross-sections on minor actinides for next generation reactors: new data from n_TOF (CERN)  

International Nuclear Information System (INIS)

Full text: Climatic problems associated to the greenhouse effect have recently stimulated a renewed interest in nuclear energy production, and triggered new studies aimed at developing future generation systems that would address current major safety, proliferation and waste concerns. In particular a possible solution to the waste problem could come from transmutation of the highly radiotoxic nuclear waste in Accelerator Driven Systems or in Generation-IV fast nuclear reactors. The design and operation of the new systems require accurate cross-section data on a large number of isotopes, in particular plutonium, minor actinides, long-lived fission fragments and structural materials. An important contribution to the field is being provided since a few years by a new time of-flight facility operative at CERN, n_TOF. The main features of the neutron beam, in particular the wide energy spectrum, ranging from thermal energy to hundreds of MeV, the ...

2008-06-01

391

Indicators of safety culture - selection and utilization of leading safety performance indicators  

International Nuclear Information System (INIS)

Safety indicators play a role in providing information on organizational performance, motivating people to work on safety and increasing organizational potential for safety. The aim of this report is to provide an overview on leading safety indicators in the domain of nuclear safety. The report explains the distinction between lead and lag indicators and proposes a framework of three types of safety performance indicators - feedback, monitor and drive indicators. Finally the report provides guidance for nuclear energy organizations for selecting and interpreting safety indicators. It proposes the use of safety culture as a leading safety performance indicator and offers an example list of potential indicators in all three categories. The report concludes that monitor and drive indicators are so ...

2010-05-01

392

Insulin therapy in critically ill patients  

UK PubMed Central (United Kingdom)

Hyperglycemia frequently occurs with acute medical illness, especially among patients with cardiovascular disease, and has been linked to increased morbidity and mortality in critically ill patients....Full Text Available

2010-01-01

393

Critical Limb Ischemia  

UK PubMed Central (United Kingdom)

Opinion statementCritical limb ischemia (CLI), defined as chronic ischemic rest pain, ulcers, or gangrene attributable to objectively proven arterial occlusive disease, is the most advanced...Full Text Available

2010-06-01

394

2011 Critical Use Exemption Nominations from the Phaseout of...  

Science.gov (United States)

transmitted to the Ozone Secretariat of the United Nations Environment Programme (UNEP) its sixth nomination for a critical use exemption (CUE) from the phaseout of methyl...

2011-02-08

395

Computerised, remote monitoring systems for underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

This report presents a study on the use of computerised, continuous remote monitoring systems for fire and explosive atmosphere safety in underground coal mines. The effects of these systems on the safety level in mines are investigated, and the relationship between mine safety regulations and computerised, continuous, remote monitoring is analysed.

1983-03-01

396

The operating experience for Wolsung Unit 3 commissioning  

International Nuclear Information System (INIS)

This is a slide-based oral presentation given to the COG/IAEA: Fifth technical committee meeting on 'Exchange of operating experience of pressurized heavy water reactors' held in Mangalia, Romania on 7-10 September 1998. Since energization of Wolsung Unit 3 station service transformer on July 12, 1996 a line of initial test program was conducted as follows: 1. ILRT/SIT; 2. Pre-operational and Hot Functional testing with a Light Water and without Fuel in Systems; 3. Load D_2O in Moderator System; 4. Initial fuel loading; 5. Load D_2O in PHT System; 6. Hot Functional Testing with Heavy Water and Fuel in Systems; 7. Criticality and Low Power Physics Testing; 8. Power Ascension Test and, then finally, phase-D test; the plant acceptance test was accomplished after having a Mini-Overhaul to prepare for Commercial Operation. These documents contain not only both overall introduction of commissioning and the first TBN rolling and Synchronization test performed in Hot ...

1998-09-07

397

Survey of systems safety analysis methods and their application to nuclear waste management systems  

Energy Technology Data Exchange (ETDEWEB)

This report reviews system safety analysis methods and examines their application to nuclear waste management systems. The safety analysis methods examined include expert opinion, maximum credible accident approach, design basis accidents approach, hazard indices, preliminary hazards analysis, failure modes and effects analysis, fault trees, event trees, cause-consequence diagrams, G0 methodology, Markov modeling, and a general category of consequence analysis models. Previous and ongoing studies on the safety of waste management systems are discussed along with their limitations and potential improvements. The major safety methods and waste management safety related studies are surveyed. This survey provides information on what safety methods are available, what waste management safety areas have been analyzed, and what are potential areas ...

1981-11-01

399

Fire Safety Concerns in Space Operations - NASA Technical Reports ...  

Science.gov (United States)

familiarity fire triangle (i.e., fuel, oxidant, and ignition source) are excluded. It Is obvious that for the baseline safety goal for spacecraft this ...

400

Explosives - hazard management  

Energy Technology Data Exchange (ETDEWEB)

The management of risks of explosives are described. Administrative and procedural controls are considered. The safety management plan involves hazard identification, risk analysis, assessment and control. The current position of explosives safety is considered. 4 tabs.

1998-12-31

401

Comments on the NRC safety research program budget for fiscal year 1982  

Energy Technology Data Exchange (ETDEWEB)

Recommendations of the Advisory Committee on Reactor Safeguards are presented to the Commissioners for their consideration for FY 82 budget for the NRC safety research program.

1980-07-01

402

Comments on the NRC safety research program budget for Fiscal Year 1983  

Energy Technology Data Exchange (ETDEWEB)

Recommendations of the Advisory Committee on Reactor Safeguards are presented to the Commissioners for their consideration for FY 83 budget for the NRC safety research program.

1981-07-01

403

A bibliography of AECL publications on reactor safety  

International Nuclear Information System (INIS)

AECL Publications on Reactor Safety in CANDU Reactors are listed in this bibliography. The listing is chronological and the accompanying index is by subject. The bibliography will be brought up to date annually. (auth).

1995-05-08

404

Resolving conflicting safety cultures  

International Nuclear Information System (INIS)

Several nuclear power plant sites have been wounded in the crossfire between two distinct corporate cultures. The traditional utility culture lies on one side and that of the nuclear navy on the other. The two corporate cultures lead to different perceptions of open-quotes safety culture.close quotes This clash of safety cultures obscures a very important point about nuclear plant operations: Safety depends on organizational learning. Organizational learning provides the foundation for a perception of safety culture that transcends the conflict between utility and nuclear navy cultures. Corporate culture may be defined as the knowledge, attitudes, and beliefs shared by employees of a given company. Safety culture is the part of corporate culture concerning shared attitudes and beliefs affecting individual or public safety. If the safety ...

1993-06-20

408

Variations in humanized and defined culture conditions supporting derivation of new human embryonic stem cell lines  

DEFF Research Database (Denmark)

The evolution of "humanized" (i.e., free of animal sourced reagents) and ultimately chemically defined culture systems for human embryo stem cell (hESC) isolation and culture is of importance to improving their efficacy and safety in research and therapeutic applications. This can be achieved by integration of a multitude of individual approaches to replace or eliminate specific animal sourced reagents into a single comprehensive protocol. In the present study our objective was to integrate strategies obviating reliance on some of the most poorly defined and path-critical factors associated with hESC derivation, namely the use of animal immune compliment to isolate embryo inner cell mass, and animal sourced serum products and feeder cells to sustain hESC growth and attachment. As a result we report the derivation of six new hESC lines isolated by outgrowth from whole blastocysts on an extracellular matrix substrate of purified human laminin ...

2006-01-01

409

U.S. Department of Energy strategic plan  

Energy Technology Data Exchange (ETDEWEB)

With the end of the Cold War and the election of President Clinton, the Department of Energy (DOE) set a new course which began with the publication of its first departmental strategic plan in April 1994. Entitled ``Fueling a Competitive Economy, it provided the framework and shared vision for meeting responsibilities in energy, national security, environmental quality, and science and technology. The strategic plan was the guidepost for the formulation of the Department`s FY 1996, FY 1997, and FY 1998 budgets and was critical to the development of the Department`s Strategic Alignment Initiative, designed to save $1.7 billion over five years. This current plan, which has been significantly improved through a very close consultation process with Congress and customers stakeholders, takes DOE to the next important performance level by being more directly linked to actions and results. It defines a strategic goal for each of the Department`s four business lines and, ...

1997-09-01

410

Study of radionuclide contributing to dose rates in 540 MWe plant environment  

International Nuclear Information System (INIS)

Tarapur Atomic Power Station Unit-4 is first 540 MWe pressurized heavy water reactor in India. It achieved criticality on 06th March 2005 and then operated at full power i.e 500 MWe. Radiation workers during the normal operation and reactor shutdown are exposed to radiation field. The control of dose rates and the collective dose of the radiation workers is most important for the best performance of the reactor. Experience gained during the operation of the 220 MWe reactors has shown that the Moderator system, primary heat transport system, annulus gas system and moderator cover gas system are the main systems contributing to the dose rate and collective dose. In order to identify the radio nuclides contributing to the radiation field, study was undertaken at TAPS Unit-4. Various samples from the Moderator, primary heat transport system, annulus gas system and moderator cover gas system were collected and analysed for the spectrometric analysis. This paper ...

2005-11-23

411

Results of 1995 characterization of Gunite and Associated Tanks at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This technical memorandum (TM) documents the 1995 characterization of eight underground radioactive waste tanks at Oak Ridge National Laboratory (ORNL). These tanks belong to the Gunite and Associated Tanks (GAAT) operable unit, and the characterization is part of the ongoing GAAT remedial investigation/feasibility study (RI/FS) process. This TM reports both field observations and analytical results; analytical results are also available from the Oak Ridge Environmental Information System (OREIS) data base under the project name GAAT (PROJ-NAME = GAAT). This characterization effort (Phase II) was a follow-up to the {open_quotes}Phase I{close_quotes} sampling campaign reported in Results of Fall 1994 Sampling of Gunite and Associated Tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee, ORNL/ER/Sub/87-99053/74, June 1995. The information contained here should be used in conjunction with that in the previous TM. The sampling plan is documented in ORNL Inactive Waste Tanks ...

1996-02-01

412

Gas Storage Technology Consortium  

Energy Technology Data Exchange (ETDEWEB)

Gas storage is a critical element in the natural gas industry. Producers, transmission and distribution companies, marketers, and end users all benefit directly from the load balancing function of storage. The unbundling process has fundamentally changed the way storage is used and valued. As an unbundled service, the value of storage is being recovered at rates that reflect its value. Moreover, the marketplace has differentiated between various types of storage services and has increasingly rewarded flexibility, safety, and reliability. The size of the natural gas market has increased and is projected to continue to increase towards 30 trillion cubic feet over the next 10 to 15 years. Much of this increase is projected to come from electric generation, particularly peaking units. Gas storage, particularly the flexible services that are most suited to electric loads, is crucial in meeting the needs of these new markets. To address the gas ...

2007-06-30

413

Developing effective professional bus driver health programs: An investigation of self-rated health.  

Science.gov (United States)

The health of professional bus drivers is a critical factor in their driving performance; any impairment may lead to undesired consequences. In an attempt to develop and prioritize health and wellness programs, this study investigates the factors significantly affecting the health conditions of professional bus drivers, as well as the strength of these factors. This study uses self-rated health as the examination measurement. This simple assessment is an inclusive measure of health status for judging health trajectory, and is highly associated with changes in functional ability, including perceived control over driving. This study evaluates driver responses of self-rated health with ordered response models that consider factors such as the driver reported health problems, physical and psychological conditions, demographic factors, driving experience, and working environment. Analysis of a sample of 785 drivers shows that age, body mass index, depression, daily ...

2011-06-24

414

Continuum damping of toroidal Alfven eigenmodes in finite-#beta# tokamak equilibria  

International Nuclear Information System (INIS)

A general theoretical approach for the study of the two-dimensional structure of high-n Toroidal Alfven Eigenmodes (TAE) in finite-#beta#, large aspect ratio (R_o/a much-gt 1) tokamak equilibria is presented. Here, n is the toroidal mode number, #beta# = plasma/magnetic pressure, and a(R_o) is the minor (major) radius of the torus. It is shown how the general pseudo-differential boundary value problem for the radial eigenmode structure can be systematically constructed from the local dispersion relation; which is obtained using the ballooning formalism. The TAE modes are characterized by a broad radial envelope, the width of which is independent on the mode number in the general case of monotonic equilibrium profiles. The results on the two-dimensional eigenmode structure are expected to be applicable to drift-type waves. The ballooning transform is generalized here to handle singular eigenfunctions typical of the continuous shear Alfven spectrum, and, thereby, facilitates the ...

415

Benchmark Analysis of Subcritical Noise Measurements on a Nickel-Reflected Plutonium Metal Sphere  

Energy Technology Data Exchange (ETDEWEB)

Subcritical experiments using californium source-driven noise analysis (CSDNA) and Feynman variance-to-mean methods were performed with an alpha-phase plutonium sphere reflected by nickel shells, up to a maximum thickness of 7.62 cm. Both methods provide means of determining the subcritical multiplication of a system containing nuclear material. A benchmark analysis of the experiments was performed for inclusion in the 2010 edition of the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Benchmark models have been developed that represent these subcritical experiments. An analysis of the computed eigenvalues and the uncertainty in the experiment and methods was performed. The eigenvalues computed using the CSDNA method were very close to those calculated using MCNP5; however, computed eigenvalues are used in the analysis of the CSDNA method. Independent calculations using KENO-VI provided similar eigenvalues to those ...

2009-09-01

416

A study of passive and inherent safety design concepts for advanced light= water reactors  

Energy Technology Data Exchange (ETDEWEB)

The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of condensation heat transfer and effect of non-condensable gases) on the condensation ...

1997-07-01

417

UNITED STATES DEPARTMENT OF ENERGY WASTE PROCESSING ANNUAL TECHNOLOGY DEVELOPMENT REPORT 2007  

Energy Technology Data Exchange (ETDEWEB)

The Office of Environmental Management's (EM) Roadmap, U.S. Department of Energy--Office of Environmental Management Engineering & Technology Roadmap (Roadmap), defines the Department's intent to reduce the technical risk and uncertainty in its cleanup programs. The unique nature of many of the remaining facilities will require a strong and responsive engineering and technology program to improve worker and public safety, and reduce costs and environmental impacts while completing the cleanup program. The technical risks and uncertainties associated with cleanup program were identified through: (1) project risk assessments, (2) programmatic external technical reviews and technology readiness assessments, and (3) direct site input. In order to address these needs, the technical risks and uncertainties were compiled and divided into the program areas of: Waste Processing, Groundwater and Soil Remediation, and Deactivation ...

2008-08-12

418

Stability and chaotification of vibration isolation floating raft systems with time-delayed feedback control  

Science.gov (United States)

This paper presents a systematic study on the stability of a two-dimensional vibration isolation floating raft system with a time-delayed feedback control. Based on the generalized Sturm criterion, the critical control gain for the delay-independent stability region and critical time delays for the stability switches are derived. The critical conditions can provide a theoretical guidance of chaotification design for line spectra reduction. Numerical simulations verify the correctness of the approach. Bifurcation analyses reveal that chaotification is more likely to occur in unstable region defined by these critical conditions, and the stiffness of the floating raft and mass ratio are the sensitive parameters to reduce critical control gain.

2011-09-01

419

Thermal reactor safety  

International Nuclear Information System (INIS)

Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

1990-09-01

420

Thermal reactor safety  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

1980-06-01

421

Table of Contents  

British Library Electronic Table of Contents (United Kingdom)

Abstract Overall Numbers Small, But Study Finds SSRI Exposure, Autism Link Additional Drug Safety, Efficacy Data Needed for Pediatric Bipolar Disorder SGA Safety and Efficacy in Children and Adolescents Aripiprazole Safety and Tolerability for Irritability in Autism No Lisdexamfetamine Effect on Sleep Disturbances in Children With ADHD Sickle Cell Disease With Comorbid Depression Homeopathy in Psychiatry Manic Symptoms Induced by Marijuana in a Healthy Adolescent New Warnings Safety Labeling Changes

2011-01-01

423

Optimization of the availability-safety pair for propulsion boilers; Optimisation du couple, disponibilite - surete pour les chaufferies de propulsion  

Energy Technology Data Exchange (ETDEWEB)

The relations between nuclear energy availability and nuclear plant safety are analyzed in the particular cases of naval propulsion nuclear boilers (aircraft carriers, submarines): safety objectives, present and potential risk analysis, optimization of the availability-safety couple, at the design stage and during operation (procedural rules related to the boiler state, real time decisions). 6 fig., 1 tab.

1994-12-31

426

Integrated Safety Management System Phase I Verification for the Plutonium Finishing Plant (PFP) [VOL 1 & 2  

Energy Technology Data Exchange (ETDEWEB)

U.S. Department of Energy (DOE) Policy 450.4, Safety Management System Policy commits to institutionalizing an Integrated Safety Management System (ISMS) throughout the DOE complex as a means of accomplishing its missions safely. DOE Acquisition Regulation 970.5204-2 requires that contractors manage and perform work in accordance with a documented safety management system.

2000-01-10

427

Design, fabrication, qualification and reliability of the major components of ''MONJU'' from a safety point of view  

International Nuclear Information System (INIS)

This paper will review code and standard and the safety related features of major components of Monju: Components of the Reactor Coolant Boundary; Components of the Reactor Shurdown Systems; Components of the Decay Heat Removal Systems; Components of the Engineered Safety Features; Other Safety Related Components. Their relationship to the system or plant function is emphasized, in reviewing these components.

1982-07-01

428

Role of FFTF in assessing structural feedbacks and inherent safety of LMR's  

International Nuclear Information System (INIS)

The possibility of developing reactor designs with inherent safety characteristics sufficient to provide walk away safety is receiving additional emphasis in the LMR program. A key element in this effort is the recognition that LMR's possess safety characteristics above and beyond those employed in past safety review processes. Some of these additional safety characteristics are due to reactivity feedback effects caused by small structural movements during hypothetical severe design transients. The effects of these characteristics upon the behavior of the FFTF under such transients has been assessed and is discussed in this paper. The paper also presents a preliminary test matrix which might allow experimental verification of the structural reactivity feedback effects. Such experimental verification should be very useful to innovative designers seeking to optimize inherent ...

1985-07-01

429

Role of FFTF in assessing structural feedbacks and inherent safety of LMR's  

International Nuclear Information System (INIS)

The possibility of developing reactor designs with inherent safety characteristics sufficient to provide ''walk away'' safety is receiving additional emphasis in the LMR program. A key element in this effort is the recognition that LMR's possess safety characteristics above and beyond those employed in past safety review processes. Some of these additional safety characteristics are due to reactivity feedback effects caused by small structural movements during hypothetical severe design transients. The effect of these characteristics upon the behavior of the FFTF under such transients has been assessed and is discussed in this paper. The paper also presents a preliminary test matrix which might allow experimental verification of the structural reactivity feedback effects. Such experimental verification should be very useful to innovative designers seeking to optimize inherent ...

1985-04-21

430

Development of Reliability Data Management System (RDMS) for safety systems of PHWR type plants  

International Nuclear Information System (INIS)

The Reliability Data Management System (RDMS) for safety systems of PHWR type plants has been developed and utilized in the reliability analysis of the special safety systems of Wolsong Unit 1 with plant overhaul period lengthened. The RDMS is developed for the periodic efficient reliability analysis of the safety systems of Wolsong Unit 1. In addition, this system provides the function of analyzing the effects on safety system unavailability if the test period of a test procedure changes as well as the function of optimizing the test periods of safety-related test procedures. The RDMS can be utilized in handling the requests of the regulatory institute actively with regard to the reliability validation of safety systems.

1999-10-01

431

Development and application of technology-neutral safety requirements for the regulation of new nuclear power reactors  

International Nuclear Information System (INIS)

This paper explores the current trends in development of technology-neutral safety requirements to be used in the regulation of future nuclear power reactors and the role of the quantitative safety goals in the design of reactor safety systems. Establishing the requirements concerning the reliability of safety functions rather than on particular systems employed to achieve the functions, as well as the use of the recommendations of the International Commission on Radiological Protection (ICRP) on protection against potential exposure could form the basis of a technology-neutral framework for safety requirements on new reactor designs. Also it could contribute to international harmonisation of nuclear safety assessment practices as part of the licensing processes for future nuclear power plants. (author)

2009-10-12

432

NRC safety research in support of regulation--FY 1989  

Energy Technology Data Exchange (ETDEWEB)

This report, the fifth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1989. The goal of this office is to ensure that safety-related research provides the technical bases for rulemaking and for related decisions in support of NRC licensing and inspection activities. This research is necessary to make certain that the regulations that are imposed on licensees provide an adequate margin of safety so as to protect the health and safety of the public. This report describes both the direct contributions to scientific and technical knowledge with regard to nuclear safety and their regulatory applications.

1990-04-01

433

NRC safety research in support of regulation, FY 1991. Volume 6  

Energy Technology Data Exchange (ETDEWEB)

This report, the seventh in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1991. The goal of this office is to ensure that safety-related research provides the technical bases for rulemaking and for related decisions in support of NRC licensing and inspection activities. This research is necessary to make certain that the regulations that are imposed on licensees provide an adequate margin of safety so as to protect the health and safety of the public. This report describes both the direct contributions to scientific and technical knowledge with regard to nuclear safety and their regulatory applications.

1992-04-01

434

NRC safety research in support of regulation, FY 1991  

Energy Technology Data Exchange (ETDEWEB)

This report, the seventh in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1991. The goal of this office is to ensure that safety-related research provides the technical bases for rulemaking and for related decisions in support of NRC licensing and inspection activities. This research is necessary to make certain that the regulations that are imposed on licensees provide an adequate margin of safety so as to protect the health and safety of the public. This report describes both the direct contributions to scientific and technical knowledge with regard to nuclear safety and their regulatory applications.

1992-04-01

435

NRC safety research in support of regulation, FY 1990  

Energy Technology Data Exchange (ETDEWEB)

This report, the sixth in a series of annual reports, was prepared in response to congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during FY 1990. The goal of this office is to ensure that safety-related research provides the technical bases for rulemaking and for related decisions in support of NRC licensing and inspection activities. This research is necessary to make certain that the regulations that are imposed on licensees provide an adequate margin of safety so as to protect the health and safety of the public. This report describes both the direct contributions to scientific and technical knowledge with regard to nuclear safety and their regulatory applications.

1991-04-01

436

NRC safety research in support of regulation, 1988  

Energy Technology Data Exchange (ETDEWEB)

This report, the fourth in a series of annual reports, was prepared in response to Congressional inquiries concerning how nuclear regulatory research is used. It summarizes the accomplishments of the Office of Nuclear Regulatory Research during 1988. The goal of this office is to ensure that safety-related research provides the technical bases for rulemaking and for related decisions in support of NRC licensing and inspection activities. This research is necessary to make certain that the regulations that are imposed on licensees provide an adequate margin of safety so as to protect the health and safety of the public. This report describes both the direct contributions to scientific and technical knowledge with regard to nuclear safety and their regulatory applications.

1989-05-01

437

Development of safety function assessment trees for pressurized heavy water reactor LP/SD operations  

Energy Technology Data Exchange (ETDEWEB)

The objective of Configuration Risk Management Program(CRMP) is to maintain the safety level by assuring the defense-in-depth of nuclear power plant while the configurations are changed during plant operations, especially for the LP/SD. Such a safety purpose can be achieved by establishing the risk monitoring programs with both quantitative and qualitative features. Generally, the quantitative risk evaluation models, i.e., PRA models are used for the risk evaluation during full power operation, and the qualitative risk evaluation models such as safety function assessment trees are used. Through this study, safety function assessment trees were developed.

2003-10-01

438

Safety performance indicators. Topical issues paper no. 5  

International Nuclear Information System (INIS)

Since its creation the nuclear industry has been struggling with the question of how safe is safe enough. Safety is a common goal to all involved in the design, operation and regulation of a nuclear installation. As a concept safety is not easy to define. However, there is a general understanding of what attributes a nuclear power plant should have in order to operate safely. The challenge lies in measuring the attributes. The new competitive open electricity market, in many countries throughout the world, is increasing the economic pressure on operators to lower operating costs without jeopardizing safety. Challenges are occurring at a rate that is unprecedented in the nuclear industry: competitiveness; downsizing; ageing; policy changes; reorganization; restructuring; mergers; globalization; and takeovers demand increasing attention to the management of safety. There are various means to measure ...

2001-09-03

439

Occurrence of fecal indicator bacteria in surface waters and the subsurface aquifer in Key Largo, Florida.  

UK PubMed Central (United Kingdom)

Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available

1995-06-01

440

Minimizing energy consumption of accelerators and storage ring facilities  

Science.gov (United States)

The discussion of energy usage falls naturally into three parts. The first is a review of what the problem is, the second is a description of steps that can be taken to conserve energy at existing facilities, and the third is a review of the implications of energy consumption on future facilities.

441

[caCORE: core architecture of bioinformation on cancer research in America].  

Science.gov (United States)

A critical factor in the advancement of biomedical research is the ease with which data can be integrated, redistributed and analyzed both within and across domains. This paper summarizes the Biomedical Information Core Infrastructure built by National Cancer Institute Center for Bioinformatics in America (NCICB). The main product from the Core Infrastructure is caCORE--cancer Common Ontologic Reference Environment, which is the infrastructure backbone supporting data management and application development at NCICB. The paper explains the structure and function of caCORE: (1) Enterprise Vocabulary Services (EVS). They provide controlled vocabulary, dictionary and thesaurus services, and EVS produces the NCI Thesaurus and the NCI Metathesaurus; (2) The Cancer Data Standards Repository (caDSR). It provides a metadata registry for common data elements. (3) Cancer Bioinformatics Infrastructure Objects (caBIO). They provide Java, Simple Object Access Protocol and ...

2006-04-18

442

Thermal fatigue of HIPed W/Cr-bronze divertor small scale mock-ups  

International Nuclear Information System (INIS)

Thermal fatigue is one of the key factors governing the lifetime of the divertor plate. Tungsten is a promising candidate to cover the surface of the divertor plate in the design of the international thermonuclear experimental reactor (ITER). The W/Cr-bronze divertor small scale mock-ups were manufactured by hot isostatic pressing (HIPing) technique. Thermal fatigue tests of W/Cr-bronze divertor mock-ups have been carried out by an electron beam facility. The mock-ups were tested under a cyclic surface heat flux of 9 MW m"-"2 for 1000 cycles. The electron beam was loaded on the mock-up surface for 20 s and unloaded for 20 s, alternately. The flow rate of water coolant was 0.1 L s"-"1. The 0.3 mm diameter NiCr-NiSi thermocouples were used to monitor the temperature distribution of the mock-up. It was found that the maximum temperature of the tungsten surface was about 400 degree sign C. The saturated temperature at the joint of tungsten and Cr-bronze was 160 degree ...

2004-11-15

443

Technology management for heavy oil  

Energy Technology Data Exchange (ETDEWEB)

The framework for investment in research and development (R&D) at a medium-sized Canadian petroleum company is described. The importance of R&D is illustrated by a graph showing the strong positive correlation between R&D intensity and sales for companies in the mainstream oil and gas sector in the USA. Strong R&D efforts also help to maintain market share and enhance corporate ability to transfer technology into its operations. Three ways of structuring, developing, and transferring technology are outlined: using in-house R&D facilities, which is too costly for medium-sized firms; having a central group responsible for funding third-party R&D, transferring technology into the company, and being aware of technology activities within and outside the company; and complete decentralizing of R&D, in which operations decides how, when, and what to spend on R&D. For the medium-sized company, the second option is considered the best choice. ...

1994-12-31

444

Single-pass high-gain free electron laser electron beam diagnostics  

International Nuclear Information System (INIS)

Consensus reached in the last few years that fourth generation light source will most likely be a X-ray or a UV coherent source based on single-pass high-gain free electron laser (FEL), such as Self Amplified Spontaneous Emission (SASE), or seeded high-gain harmonic-generation (HGHG) free electron lasers. High-gain (>10"7) required for single-pass FEL puts great constrain on the quality of electron beam, and demands detailed distribution information of electron beam in six-dimension. The typical accelerator system for single-pass FEL consists of a photocathode RF gun injection system, a linac and magnetic bunch compressors, and a long undulator. The major challenges in beam diagnostics for single-pass FEL are to characterize the pico-seconds high-brightness electron beam in six-dimension produced by photocathode RF gun injector, and improve the stability and reliability of the photocathode RF gun injection system. Characterization of short electron bunch (#approx#100 fs) produced by ...

2000-11-27

445

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. The method can be employed especially where conventional ...

446

Production capabilities in US nuclear reactors for medical radioisotopes  

Energy Technology Data Exchange (ETDEWEB)

The availability of reactor-produced radioisotopes in the United States for use in medical research and nuclear medicine has traditionally depended on facilities which are an integral part of the US national laboratories and a few reactors at universities. One exception is the reactor in Sterling Forest, New York, originally operated as part of the Cintichem (Union Carbide) system, which is currently in the process of permanent shutdown. Since there are no industry-run reactors in the US, the national laboratories and universities thus play a critical role in providing reactor-produced radioisotopes for medical research and clinical use. The goal of this survey is to provide a comprehensive summary of these production capabilities. With the temporary shutdown of the Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) in November 1986, the radioisotopes required for DOE-supported radionuclide generators were made available at ...

1992-11-01

447

PNC`s proposal on the Advanced Fuel Recycle concept  

Energy Technology Data Exchange (ETDEWEB)

MOX fuel for FBR is allowed to contain impurities within several thousand ppm, which means less than 1000 of decontamination factor (DF) in reprocessing is enough for Pu and U recycle use. The Advanced Fuel Recycle proposed by PNC is on this basis. The concept consists of innovations on both MOX fuel fabrication and aqueous reprocessing technologies based on the Purex process and it is believed that successful optimization of fuel cycle interface condition is the key issue to realize the concept. The lower DF such as 1000 can be easily obtained by the simplified Purex flowsheet which has no purification steps. However, new subject arises in MOX fuel fabrication, that is, fabrication is conducted in the shielding cell using equipment which is maintained remotely. A simplified fabrication technology becomes essential to establish the remote maintenance system and is one of the critical path for achieving the Advanced Fuel Recycle. The PNC`s proposal on the advanced ...

1998-03-01

448

Kootenai River Floodplain Ecosystem Operational Loss Assessment, Protection, Mitigation and Rehabilitation, 2007-2008 Annual Report.  

Science.gov (United States)

The overarching goals of the 'Kootenai River Floodplain Ecosystem Operational Loss Assessment, Protection, Mitigation and Rehabilitation' Project (BPA Project No.2002-011-00) are to: (1) assess abiotic and biotic factors (i.e., geomorphologic, hydrological, aquatic and riparian/floodplain communities) in determining a definitive composition of ecological integrity, (2) develop strategies to assess and mitigate losses of ecosystem functions, and (3) produce a regional operational loss assessment framework. To produce a scientifically defensible, repeatable, and complete assessment tool, KTOI assembled a team of top scientists in the fields of hydrology, hydraulics, ornithology, entomology, statistics, and river ecology, among other expertise. This advisory team is known as the Research Design and Review Team (RDRT). The RDRT scientists drive the review, selection, and adaptive management of the research designs to evaluate the ecologic functions lost due to the ...

2009-02-18

449

Arid sites stakeholder participation in evaluating innovative technologies: VOC-Arid Site Integrated Demonstration  

Energy Technology Data Exchange (ETDEWEB)

Developing and deploying innovative environmental cleanup technologies is an important goal for the U.S. Department of Energy (DOE), which faces challenging remediation problems at contaminated sites throughout the United States. Achieving meaningful, constructive stakeholder involvement in cleanup programs, with the aim of ultimate acceptance of remediation decisions, is critical to meeting those challenges. DOE`s Office of Technology Development sponsors research and demonstration of new technologies, including, in the past, the Volatile Organic Compounds Arid Site Integrated Demonstration (VOC-Arid ID), hosted at the Hanford Site in Washington State. The purpose of the VOC-Arid ID has been to develop and demonstrate new technologies for remediating carbon tetrachloride and other VOC contamination in soils and ground water. In October 1994 the VOC-Arid ID became a part of the Contaminant Plume Containment and Remediation Focus Area (Plume Focus Area). The VOC ...

1995-05-01

450

An overview of the development of the first wall and other principal components of a laser fusion power plant  

International Nuclear Information System (INIS)

This paper introduces the JNM Special Issue on the development of a first wall for the reaction chamber in a laser fusion power plant. In this approach to fusion energy a spherical target is injected into a large chamber and heated to fusion burn by an array of lasers. The target emissions are absorbed by the wall and encapsulating blanket, and the resulting heat converted into electricity. The bulk of the energy deposited in the first wall is in the form of X-rays (1.0-100 keV) and ions (0.1-4 MeV). In order to have a practical power plant, the first wall must be resistant to these emissions and suffer virtually no erosion on each shot. A wall candidate based on tungsten armor bonded to a low activation ferritic steel substrate has been chosen as the initial system to be studied. The choice was based on the vast experience with these materials in a nuclear environment and the ability to address most of the key remaining issues with existing facilities. This ...

2005-12-15

451

Evaluation of the residual radiation field in the proton accelerator facility of the Proton Engineering Frontier Project (PEFP) in Korea  

British Library Electronic Table of Contents (United Kingdom)

In Korea, the Proton Engineering Frontier Project (PEFP) is building a proton linear accelerator facility with energy up to 100MeV and a beam current of 20mA. In this study, a radiation field after shutdown in the accelerator facility of the PEFP was evaluated for the purpose of the radiation shielding by using MCNPX code. A facility modeling was performed for the accelerator tunnel building, accelerator chain, target rooms and beam experiment hall. And radiation source terms were evaluated in the facility. With this facility, model and radiation source terms, the concentration of 41Ar was evaluated and the cooling time satisfying regulation in Korea was calculated.

2007-01-01

452

Integrated Safeguards proposal for Finland. Final report on Task FIN C 1264 of the Finnish Support Programme to IAEA Safeguards  

Energy Technology Data Exchange (ETDEWEB)

The IAEA has requested several member states to present their proposal of the application of the Integrated Safeguards (IS) system in their nuclear facilities. This report contains a IS proposal for Finland prepared under the Task FIN C 1264 of The Finnish Support Programme to IAEA Safeguards. The comprehensive safeguards system of the International Atomic Energy Agency (IAEA) has been one of the main tools in the fight against nuclear proliferation since the entry-into-force of the Nuclear Non-proliferation Treaty three decades ago. In the 1990s some of the inherent weaknesses of this so-called traditional safeguards system were revealed first in Iraq and then in North Korea. Therefore, the member states of the LAEA decided to give the Agency additional legal authority in order to make its control system more effective as well as more efficient than before. This was accomplished by the approval of the so-called Model Additional Protocol (INFCIRC/540) in 1997. ...

2000-08-01

453

Husky Oil's White Rose gets ready to bloom  

Energy Technology Data Exchange (ETDEWEB)

The South White Rose oilfield, offshore Newfoundland, owned jointly by Husky Oil (82.5 per cent ) and Petro-Canada (17.5 per cent) is being developed using a floating production storage and offloading (FPSO) system. Some industry stakeholders claim that the oil should be produced using a concrete gravity base system as used in the Hibernia Field. However, Husky Oil officials are confident that the choice of the FPSO is well justified, based on its cost effectiveness and economic viability. Several production facility options have been assessed, taking into account feasibility, deliverability, economic attributes. risk and safety . The assessment results clearly pointed to FPSO as the preferred system based on its commercial and technical flexibility, proven track record in harsh environments, its ability to produce both oil and gas in sequential development, its promise of production at full capacity earlier than a gravity base system, and ...

2000-06-01

454

Challenges for Lithuania: Ignalina NPP Early Closure  

International Nuclear Information System (INIS)

As a condition of accession into the European Union (EU), Lithuania is committed to the closure and decommissioning of Ignalina NPP comprising two RBMK-1500 reactor units (Fig. 1). It was agreed in a special protocol to the Accession Treaty that, in return for adequate EU financial assistance, Unit 1 would be closed before 2005 and Unit 2 by the end of 2009. The first unit was duly shut down on December 31, 2004. Lithuania, which has borders with Russia (Kaliningrad territory), Poland, Latvia and Belarus, spent fifty years as part of the Soviet Union and was deeply integrated into its economy and electrical infrastructure. At the break-up of the USSR, Lithuania inherited electricity generating capacity designed to supply the north-west region including ownership of Ignalina NPP located in the north-east of the country. Ignalina NPP Unit 1 was commissioned in 1983, Unit 2 in 1987; the planned lifespan of each unit was 30 years. Construction of a third unit was started but never ...

2008-01-01

455

White Rose development plan amendment production volume increase  

Energy Technology Data Exchange (ETDEWEB)

In January 2001, Husky Oil Operations Limited (Husky), in joint-venture with Petro-Canada, submitted a Benefits Plan for the White Rose Development to the Canada- Newfoundland and Labrador Offshore Petroleum Board (C-NLOPB). This revised document provided the case for requesting an increase in the facility maximum daily production rate and the average annual production rate for the White Rose field from 100,000 barrels per day (bpd) as stated in the approved White Rose Development Plan to 140,000 bpd. In order to determine the potential for increasing oil production through the Floating Production, Storage and Offloading (FPSO) vessel, two things were considered, namely the proper reservoir management of the White Rose field to ensure optimum resource recovery, and the capacity of the FPSO topsides processing system and supporting utilities to accommodate increased production. This document presented a detailed review of all the implications of increased production ...

2006-09-15

456

Uranium hexafluoride production plant decommissioning; Descomissionamento de uma usina de producao de hexafluoreto de uranio  

Energy Technology Data Exchange (ETDEWEB)

The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in Brazil before, for this type of ...

2008-07-01

457

Treatment for dismantled radioactive solid waste from the TRIGA Mark-2 and 3  

Energy Technology Data Exchange (ETDEWEB)

Radioactive wastes are generally classified into 3 type depending on their physical property: liquid, solid and gaseous type. State-of -the art concerning liquid waste treatment has already been published; KAERI/TR-1315/99. Solid wastes classification package and treatment method will be studied to effectively manage them during the practical decommissioning work. All of the spent fuel produced during the operation of the TRIGA Mark-2 and 3 have been transported to the US last year, 1998, according to the spent fuel management strategy set-up by the US government for the non-proliferation of nuclear energy. Solid wastes are mainly all equipment existing inside of the reactors, activated concrete among the bio-shielded concrete, pipes, pimps, resin filter and it's housings, heat-exchangers, liquid waste storage tanks, to radioactive waste storage treatment facilities and so on. Solid wastes are generally low-level. They are classified according to the ...

1999-06-01

458

SGTR Project: Separate Effect Studies for Vertical Steam Generators  

Energy Technology Data Exchange (ETDEWEB)

The SGTR project has been carried out within the fifth EURATOM Framework Programme (Contract No FIKS-CT-1999-0007). Its main objective was to provide an experimental database and to develop and/or verify models to support definition of accident management measures in the hypothetical case of a Steam Generator tube Rupture (SGTR) sequence. The project addressed both vertical and horizontal steam generator designs. This report summarises the main results obtained in the intermediate scale experimentation that addressed Western type steam generators. The specific goal of this test programme was to investigate aerosol retention in the break stage of the secondary side of a water-empty steam generator. The test matrix consisted of 12 tests that explored the influence of variables such as break type and orientation and inlet gas flow rate. This work was performed in the PECA facility of the Laboratory for Analysis of Safety Systems (LASS). Aerosol ...

2003-07-01

459

Reprocessing of research reactor spent nuclear fuel at the PA ''Mayak''  

International Nuclear Information System (INIS)

The first Russian reprocessing facility, known as RT-1 (located at PA-Mayak in Ural region) was started on the radiochemical plant base in 1977. Nowadays RT-1 is the sole operating reprocessing plant in Russia. The main features of RT-1 is its broad spectrum of reprocessing spent nuclear fuels (SNF). The following spent fuel types are reprocessed: -) SNF from PWR reactors (WWER-440) and FB reactor (BN-600); -) SNF of transport ship reactors; -) production reactors SNF; -) research reactor spent nuclear fuel. The world-known technological processes are used at RT-1, but there are the following distinctive features. First, the universality of the three technological lines which allows not only the reprocessing of various SNF kinds, but also to implement the combined reprocessing of some types of them. Secondly, extraction of neptunium during SNF reprocessing which is used to implement its separate storage and for radioisotope production. Thirdly, target enrichment of ...

2007-03-11

460

Reprocessing of research reactor spent nuclear fuel at the PA 'Mayak'  

Energy Technology Data Exchange (ETDEWEB)

The first Russian reprocessing facility, known as RT-1 (located at PA-Mayak in Ural region) was started on the radiochemical plant base in 1977. Nowadays RT-1 is the sole operating reprocessing plant in Russia. The main features of RT-1 is its broad spectrum of reprocessing spent nuclear fuels (SNF). The following spent fuel types are reprocessed: -) SNF from PWR reactors (WWER-440) and FB reactor (BN-600); -) SNF of transport ship reactors; -) production reactors SNF; -) research reactor spent nuclear fuel. The world-known technological processes are used at RT-1, but there are the following distinctive features. First, the universality of the three technological lines which allows not only the reprocessing of various SNF kinds, but also to implement the combined reprocessing of some types of them. Secondly, extraction of neptunium during SNF reprocessing which is used to implement its separate storage and for radioisotope production. Thirdly, target enrichment of ...

2007-07-01

461

RAAN Conference. Support of Nuclear Power. Opening talk  

International Nuclear Information System (INIS)

Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fructified in the construction of Units 2-5 to be built. The Romanian Ministry of Education and Research implemented a nuclear national program for research and development taking into account the European Union requirements and recommendations, the cooperation with the IAEA - Vienna and the Romanian government policy on short and medium terms in the nuclear field. The research-development program targeted: the reactor physics and nuclear fuel management; the operation safety of ...

2002-09-06

462

Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment  

Energy Technology Data Exchange (ETDEWEB)

Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments, interacting with program management to establish the additional requirements of the program, and ...

1999-09-09

463

Oak Ridge National Laboratory Waste Management Plan, fiscal year 1994. Revision 3  

Energy Technology Data Exchange (ETDEWEB)

US Department of Energy (DOE) Order 5820.2A was promulgated in final form on September 26, 1988. The order requires heads of field organizations to prepare and to submit updates on the waste management plans for all operations under their purview according to the format in Chap. 6, {open_quotes}Waste Management Plan Outline.{close_quotes} These plans are to be submitted by the DOE Oak Ridge Operations Office (DOE-ORO) in December of each year and distributed to the DP-12, ES&H-1, and other appropriate DOE Headquarters (DOE-HQ) organizations for review and comment. This document was prepared in response to this requirement for fiscal year (FY) 1994. The Oak Ridge National Laboratory (ORNL) waste management mission is reduction, collection, storage, treatment, and disposal of DOE wastes, generated primarily in pursuit of ORNL missions, in order to protect human health and safety and the environment. In carrying out this mission, waste management staff in the ...

1993-12-01

464

Mining and milling for uranium in Japan  

International Nuclear Information System (INIS)

In Japan, the Ningyo-toge uranium deposit was discovered in 1955, and the Tono deposit in 1962. Geology of these mines is different from that of other metal mines developed in Japan. Therefore, it appeared that some changes were required in the usual mining methods applied to existing metal mines to mine uranium ore in these deposits. At the Ningyo-toge mine, effective methods were studied for mining the ore, such as the room and pillar method, long-wall method, slicing method, and the hydraulic method; as a result, it was determined that a modified long-wall method is the most useful and practicable for recovering uranium ore from this underground sedimentary deposit. Applicatons of in-place and microbiological leaching to these deposits are being studied to secure mine safety and decrease mine pollution. Since 1959, when the Ningyo-toge mine went into operation, no hazards for workers nor any pollution of the environment were permitted. Research and development ...

1959-01-01

465

Global positioning automatic vehicle location system  

Energy Technology Data Exchange (ETDEWEB)

Los Alamos National Laboratory (LANL) is a unique facility covering over 43 square miles. The Emergency Management and Response Office (EM&R) is required to respond, provide Incident Command (IC), and coordination for all Laboratory emergencies. This requires IC`s and support staff to respond to the actual scene of the incident. Since the IC is under numerous constraints and stress, the office wanted the capability of locating the EM&R vehicles on an electronic map. An automated vehicle location (AVL) system was required for the additional safety of the emergency response personal. The requirements for the AVL system include total automatic tracking and low cost. After careful consideration, it was determined that the most efficient and cost effective system would be based on packet radio technology as the transmission media. The location is determined by the Department of Defense Global Positioning System (GPS). The system that was ...

1997-03-01

466

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

Energy Technology Data Exchange (ETDEWEB)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also ...

2009-06-15

467

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

International Nuclear Information System (INIS)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also ...

2009-06-01

468

Development on the technologies for tritium removal processes  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is upto about 40 % of the total personnel exposure, Korea Institute of Nuclear Safety has asked tritium removal facility, as one of the requirements for post reactor construction, after operation of four CANDU reactors in Wolsung site. For the purpose of essential removal of tritium from the heavy water system of the heavy water reactors, an experiment of Ar-N{sub 2} cryogenic distillation tower was carried out as a preliminary study for development of liquid-phase catalytic exchange - cryogenic hydrogen distillation process. The steady-state reached after 50 minutes under 90 K in the Ar-N{sub 2} distillation column (inner diameter 20 mm, height 500 mm) packed with Dixon ring ({phi} 3 mm x H 3 mm), and the ratios of Ar-concentration at the top and at the bottom measured by gas chromatography within {+-}1 % relative error was approximately 93 : 3. This value was distillation performances ...

1994-12-01

469

Calendar year 1993 groundwater quality report for the Chestnut Ridge Hydrogeologic Regime Y-12 Plant, Oak Ridge, Tennessee. 1993 Groundwater quality data interpretations and proposed program modifications  

Energy Technology Data Exchange (ETDEWEB)

This groundwater quality report (GWQR) contains an evaluation of the groundwater quality data obtained during the 1993 calendar year (CY) at several hazardous and non-hazardous waste management facilities associated with the US DOE Y-12 Plant located on the DOE Oak Ridge Reservation (ORR) southeast of Oak Ridge, Tennessee. The groundwater quality data are presented in Part 1 of the GWQR submitted by Martin Marietta Energy Systems, Inc. to the Tennessee Department of Environment and Conservation (TDEC) in February 1994. Groundwater quality data evaluated in this report were obtained at several hazardous and non-hazardous waste management sites located within the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Chestnut Ridge Regime encompasses a section of Chestnut Ridge south of the Y-12 Plant and is one of three hydrogeologic regimes defined for the purposes of groundwater quality monitoring at the plant. The Environmental Management Department of ...

1994-09-01

470

Automated real-time testing (ARTT) for embedded control systems (ECS).  

Energy Technology Data Exchange (ETDEWEB)

Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test runs and test cases. To measure the PSS system's test coverage three levels of system requirements were mapped to their respective unit level of test using a specially constructed ...

2001-08-09

471

Automated container transportation using self-guided vehicles: Fernald site requirements  

Energy Technology Data Exchange (ETDEWEB)

A new opportunity to improve the safety and efficiency of environmental restoration operations, using robotics has emerged from advances in industry, academia, and government labs. Self-Guided Vehicles (SGV`s) have recently been developed in industry and early systems have already demonstrated much, though not all, of the functionality necessary to support driverless transportation of waste within and between processing facilities. Improved materials databases are being developed by at least two DOE remediation sites, the Fernald Environmental Management Project (FEME) in the State of Ohio and the Hanford Complex in the State of Washington. SGV`s can be developed that take advantage of the information in these databases and yield improved dispatch, waste tracking, report and shipment documentation. In addition, they will reduce the radiation hazard to workers and the risk of damaging containers through accidental collision. In this document, ...

1993-09-01

472

ANALYSIS OF ACCELERATOR BASED NEUTRON SPECTRA FOR BNCT USING PROTON RECOIL SPECTROSCOPY  

Energy Technology Data Exchange (ETDEWEB)

Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron beam energy spectra alternative neutron sources are being contemplated for wider ...

1998-11-06

473

Report on progress of researches by common utilization of JAERI nuclear facilities, for fiscal 1996  

Energy Technology Data Exchange (ETDEWEB)

This issue is the collection of the papers on progress of researches by common utilization of JAERI nuclear facilities. The 43 of the papers are indexed individually. (J.P.N.)

1998-01-01

474

Foodstuff Concentrations and Relocation Considerations Following a Tritium Oxide Release from SRS Tritium Facilities  

Energy Technology Data Exchange (ETDEWEB)

The ingestion pathway consequences following an accidental tritium release from the Savannah River Site Tritium Facilities are evaluated.

1999-05-18

475

Evaluation of the Cask Transportation Facility Modifications (CTFM) compliance to DOE order 6430.1A; FINAL  

International Nuclear Information System (INIS)

This report was prepared to evaluate the compliance of Cask Transportation Facility Modifications (CTFM) to DOE Order 6430.1A.

476

Superconducting A-15 compounds  

International Nuclear Information System (INIS)

The critical superconducting paramters of A-15 compounds are reviewed, and the trends analysed in order to predict maximum values. Experimental data on critical temperature is summarized and compared with theory. The ability to form the stoichiometric, well-ordered materials required for maximum Tsub(c) is discussed in terms of the thermodynamic stability of the A-15 phase. It is concluded that critical temperatures in excess of 25 K, in the A-15 structure, are unlikely. The upper critical field data show that, whereas the vanadium-based compounds are paramagnetically limited, the niobium-based compounds are not. The relation between critical current and microstructure is explored. Best data on critical current densities and ac losses is presented. Finally an account is given of the various methods by which actual conductors, both tapes and multifilamentary ...

477

The WHO patient safety curriculum guide for medical schools.  

Science.gov (United States)

BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate ...

2010-12-01

478

Republished paper: The WHO patient safety curriculum guide for medical schools.  

Science.gov (United States)

BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate ...

2011-04-01

479

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not ...

1999-04-02

480

Research and development on next generation reactor (phase I)  

Energy Technology Data Exchange (ETDEWEB)

The objective of the study is to improve the volume of nuclear power plant which adopts passive safety system concept. The passive safety system reactor is characterized by excellent safety and reliability. But the volume of NSSS (Nuclear Steam Supply System) of the passive safety system reactor is so small that it should be upgraded for commercial operation. For volume upgrade, detailed analyses are performed as follows; core design, hydraulics, design and mechnical structures, and safety analysis. In addition to above analysis, some investigations must be supplied as follows: power density vs. DNB margin decrease, outlet temperature vs. EPRI-URD, additional tests for upgraded reactor, dynamic analysis of mechanical vibration according to expanded reactor vessel and expanded in-core structures, and Merit loss of passive safety system reactor according to design ...

1994-10-01

481

Health, Safety, and Environment Division: Annual progress report 1987  

Energy Technology Data Exchange (ETDEWEB)

The primary responsibility of the Health, Safety, and Environment (HSE) Division at the Los Alamos National Laboratory is to provide comprehensive occupational health and safety programs, waste processing, and environment protection. These activities are designed to protect the worker, the public, and the environment. Many disciplines are required to meet the responsibilities, including radiation protection, industrial hygiene, safety, occupational medicine, environmental science, epidemiology, and waste management. New and challenging health and safety problems arise occasionally from the diverse research and development work of the Laboratory. Research programs in HSE Division often stem from these applied needs. These programs continue but are also extended, as needed to study specific problems for the Department of Energy and to help develop better occupational health and safety ...

1988-04-01

482

DOE explosives safety manual  

Energy Technology Data Exchange (ETDEWEB)

The Department of Energy (DOE) policy requires that all DOE activities be conducted in a manner that protects the safety of the public and provides a safe and healthful workplace for employees. DOE has also prescribed that all personnel be protected in any explosives operation undertaken. The level of safety provided shall be at least equivalent to that of the best industrial practice. The risk of death or serious injury shall be limited to the lowest practicable minimum. DOE and contractors shall continually review their explosives operations with the aim of achieving further refinements and improvements in safety practices and protective features. This manual describes the Department's explosive safety requirements applicable to operations involving the development, testing, handling, and processing of explosives or assemblies containing explosives. It is intended to reflect the ...

1991-10-01

483

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic ...

1989-08-15

484

A study of flow boiling phenomena using real time neutron radiography  

International Nuclear Information System (INIS)

The operation and safety of both fossil-fuel and nuclear power stations depend on adequate cooling of the thermal source involved. This is usually accomplished using liquid coolants that are forced through the high temperature regions by a pumping system; this fluid then transports the thermal energy to another section of the power station. However, fluids that undergo boiling during this process create vapor that can be detrimental, and influence safe operation of other system components. The behavior of this vapor, or void, as it is generated and transported through the system is critical in predicting the operational and safety performance. This study uses two advanced penetrating radiation techniques, Real Time Neutron Radiography (RTNR), and High Speed X-Ray Tomography (HS-XCT), to examine void generation and transport behavior in a flow boiling system. The geometries studied were tube side flow boiling in a ...

1346-01-01

485

Prediction of critical properties of mixtures from the PRSV-2 equation of state: A correction for predicted critical volumes  

Energy Technology Data Exchange (ETDEWEB)

Critical properties of a fluid or fluid mixtures are important for describing fluid phase behavior, predicting physical properties, developing equations of state, and designing supercritical-fluid extraction processes, and compression and refrigeration units. The predictive capability of the Peng-Robinson-Styjek-Vera (PRSV-2) equation of state (1986) for critical properties of binary mixtures was investigated. The procedure adopted by Heidemann and Khalil (1980) and discussed by Abu-Eishah et al. (1998) was followed. An optimized value for the binary interaction parameter based on minimization of error between experimental and predicted critical temperatures was used. The standard and the average of the absolute relative deviations in critical properties are included. The predicted critical temperature and pressure for several nonpolar and polar systems agree well with experimental ...

1999-09-01

486

Parenteral Glucose and Glucose Control in the Critically Ill: A Kinetic Appraisal  

UK PubMed Central (United Kingdom)

BackgroundWe investigated the influence of parenteral glucose infusion on insulin-driven tight glucose control (4.4–6.1 mmol/liter) in the critically ill by appraising kinetic...Full Text Available

487

Parent-Child Interactions in Relation to Critical and Emotionally Overinvolved Expressed Emotion (EE): Is EE a Proxy for Behavior?  

UK PubMed Central (United Kingdom)

Expressed emotion measures, encompassing dimensions of criticism (CRIT), and emotional overinvolvement (EOI) are increasingly being used to assess the parent–child relationship in child...Full Text Available

2004-02-01

488

Interference by new-generation mobile phones on critical care medical equipment  

UK PubMed Central (United Kingdom)

IntroductionThe aim of the study was to assess and classify incidents of electromagnetic interference (EMI) by second-generation and third-generation mobile phones on critical care...Full Text Available

2007-01-01

489

Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients  

UK PubMed Central (United Kingdom)

Anemia commonly affects critically ill patients. The causes are multifactorial and include acute blood loss, blood loss from diagnostic testing and blunted red blood cell production. Blood transfusions...Full Text Available

2008-01-01

490

An Integrated System for Total Cardiac Monitoring of the Critically Ill  

UK PubMed Central (United Kingdom)

An integrated system of micro-and mini-computers is described to acquire, analyze, store and report data on the total activity of the heart of a critically ill patient. Real-time beat and rhythm diagnoses...Full Text Available

1977-10-05