WorldWideScience
2

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

3

The LLNL computer control system  

Energy Technology Data Exchange (ETDEWEB)

Lawrence Livermore National Laboratory (LLNL) has implemented a computer control system for operation of an FN tandem accelerator. The control software utilized is the Thaumaturgic Automated Control Logic (TACL) written by the Continuous Electron Beam Accelerator Facility and co-developed with LLNL. Details of the design philosophy, hardware configuration, control software, and special control algorithms will be presented. 2 refs., 4 figs.

1991-10-03

5

Software Configuration Management Plan for the Sodium Removal System  

Energy Technology Data Exchange (ETDEWEB)

This document establishers the Software Configuration Management Plan (SCMP) for the software associated with the control system of the Sodium Removal System (SRS) located in the Interim Examination and Maintenance (IEM Cell) Facility of the FFTF Flux Test.

2000-03-06

6

Tools and methods for implementing the control systems on the Mirror Fusion Test Facility  

Energy Technology Data Exchange (ETDEWEB)

Installation of the major hardware subsystems for MFTF is nearing completion. These subsystems include the Fusion Chamber System, the eighty KV Neutral Beam System, the Superconducting Magnet System, and the Personnel Safety System. The Local Controls group has undertaken a uniform aproach to implementing the control systems for all of these hardware subsystems. This approach has two major aspects: (1) to provide a stand-alone computer control system with a remote, portable terminal so that computer control can be provided at the site of the hardware for initial testing, (2) to provide hardware simulators so that the complicated MFTF computer control system can be tested independent of the hardware. The software and hardware tools which ...

1981-09-29

7

Reactor component inventory system at FFTF  

International Nuclear Information System (INIS)

A reliable inventory control system was developed at the Fast Flux Test Facility (FFTF) to keep track of the occupancy of 900 refueling facility locations, to compile historical data on the movement of each reactor assembly, and to simulate assembly moves. The simulate capability is valuable because it allows verification of documents before they are issued for use in the plant, and eliminates the possibility of planning illegal or impossible moves. The system is installed on a UNIVAC 1100 computer and is maintained using a data base management system by Sperry Univac called MAPPER.

1985-09-08

8

Long-term preventive maintenance of instrumentation control equipment for PWR plants  

International Nuclear Information System (INIS)

Since the PWR plants in Japan have been operated more than 30 years, main instrumentation control equipment of analog systems has been renewed to digital control systems. Renewal works had to be done in short period within periodical inspection term and for several facilities. The Mitsubishi LTD group had been provided with these market needs by its digital control system (MELTAC-NplusR 3) applicable to main instrumentation control equipment for primary and secondary systems and had already finished the renewal for practical plants. (T. Tanaka)

2006-02-01

9

Sensor test facilities and capabilities at the Nevada Test Site  

Energy Technology Data Exchange (ETDEWEB)

Sandia National Laboratories has recently developed two major field test capabilities for unattended ground sensor systems at the Department of energy`s Nevada Test Site (NTS). The first capability utilizes the NTS large area, varied terrain, and intrasite communications systems for testing sensors for detecting and tracking vehicular traffic. Sensor and ground truth data can be collected at either of two secure control centers. This system also includes an automated ground truth capability that consists of differential Global Positioning Satellite (GPS) receivers on test vehicles and live TV coverage of critical road sections. Finally there is a high-speed, secure computer network link between the control centers and the Air Force`s Theater Air Command and Control Simulation Facility in Albuquerque NM. The second capability is Bunker 2-300. ...

1996-12-31

10

Facility Safety Plan B360 Complex Biohazardous Operations CMLS-412r0  

Science.gov (United States)

This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.

2007-01-08

11

Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant  

International Nuclear Information System (INIS)

This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as ...

1987-01-01

12

Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as ...

1987-09-01

13

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

14

Tap cogen-plant steam for process, NO[sub x] control  

Energy Technology Data Exchange (ETDEWEB)

This article describes the Monsanto's Indian Orchard plant gas-fired, combined-cycle cogeneration facility in Springfield, Massachusetts. The topics of the article include project configuration, the thermodynamic cycle, fuel selection, electrical distribution system, plant control, and air pollution control of NO[sub X], SO[sub 2], CO, particulates, non-methane hydrocarbons, opacity and ammonia.

1993-04-01

15

Decree of the Czechoslovak Atomic Energy Commission No. 436/1990 on quality assurance of selected facilities with respect to nuclear safety of nuclear facilities  

International Nuclear Information System (INIS)

The Decree specifies basic quality assurance requirements applicable to machines, their parts and materials, civil engineering structures, means for automated control of technological processes including hardware and software, and electricity supply systems related to nuclear safety of nuclear facilities, and stipulates binding procedures for the implementation of technical and organizational provisions associated with the quality of selected equipment to ensure nuclear safety of nuclear facilities. Safety classes are defined for selected equipment. Requirements laid on safety assurance documentation are specified, and requirements placed on safety assurance programmes, their preparation, finalization and approval are defined. Quality assurance requirements are also specified with respect to the designing, manufacture, construction, operation, repair, modification and decommissioning of nuclear ...

1995-02-01

16

Simulation of the New York Power Pool for dispatcher training  

Science.gov (United States)

This paper describes the simulation of the operating environment of the New York Power Pool (NYPP) within the Dispatcher Training Simulator facility at the New York State Electric and Gas Corporation (NYSEG). The NYSEG control center uses real-time data received from the NYPP control center to control its internal generation. In addition, the NYSEG dispatchers work very closely with the NYPP dispatchers. The exact emulation of the Generation Control functions of the NYPP EMS, and the associated data exchange with the NYSEG ECS, contribute greatly to the high degree of realism achieved in the NYSEG DTS facility. The accuracy of the power system simulation in the DTS has been validated against actual power system disturbances recorded at NYSEG.

1994-11-01

17

Safety gas management system utilizing telephone cable  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned ...

1988-02-10

18

Navy Occupational Health Information Management System (NOHIMS). Hazardous Materials Control Module. Users' manual  

Energy Technology Data Exchange (ETDEWEB)

The Hazardous Materials Control Module (HMC) is one module of four for the Industrial Health component. The HMC module was designed to inform employees of health and safety hazards in the workplace and to track the movement of hazardous materials through the facility. The module performs these functions by maintaining health and safety data on hazardous materials used in the facility, and by tracking who requests information about any hazardous materials. The HMC module gets its information from two sources. The first one is the Hazardous Materials Information System (HMIS), this is a national system that is used by the Department of Defense. It is loaded on to the system via tapes that contain all safety, health and transportation information about a particular product. The second is Material Safety Data Sheets (MSDS) that are procured by a particular site. ...

1987-01-16

19

Results of third regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken ...

1990-03-01

20

Results of second regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant ...

1988-01-01

21

Results of second regular inspection of No. 2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co. , Inc  

Energy Technology Data Exchange (ETDEWEB)

The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant ...

1988-08-01

22

Decommissioning and dismantling. Examination of the radiation hardening of electronic components. Final report  

International Nuclear Information System (INIS)

Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).

23

Information technology security at the Advanced Photon Source  

International Nuclear Information System (INIS)

The proliferation of 'botnets,' phishing schemes, denial-of-service attacks, root kits, and other cyber attack schemes designed to capture a system or network creates a climate of concern for system administrators, especially for those managing accelerator and large experimental-physics facilities, as they are very public targets. This paper will describe the steps being taken at the Advanced Photon Source (APS) to protect the infrastructure of the overall network with emphasis on security for the APS control system.

2007-10-15

25

UK Achievements in the application of power fluidic technology for nuclear processing plants  

International Nuclear Information System (INIS)

Power Fluidic systems for the control of liquids and gaseous flows have been adopted for use in radioactive processing plants in the UK. These devices are intrinsically reliable with no mechanical moving parts because they are able to make use of the hydrodynamics of the fluids being controlled. This reliability feature leads to a zero cell maintenance concept and the elimination of mechanical drive/control systems in cell. The first phase of the development work led to their use in the Fast Reactor Reprocessing Plant at Dounreay and the Highly Active Liquor Storage facility at Sellafield. The success of these early developments has led to an extensive development programme for an extended range of applications in the Thermal Oxide Reprocessing Plant and its associated waste treatment facilities at Sellafield. The technology has now been ...

26

Latest trends in rolling mill facilities toward the 21st century; 21 seiki ni muketa saishin atsuen setsubi no doko  

Energy Technology Data Exchange (ETDEWEB)

Described herein are the latest trends in rolling mill facilities toward the 21st. century and new techniques developed by Hitachi Ltd. These cover hot rolling facilities, such as two-stage twin, high crown control-roll cross mill, roll shaping machine and continuous hot rolling systems; cold rolling facilities, such as pickling line-tandem cold mill and other continuous systems; and fine steel rolling facilities, such as roll mill for very small diameter pipes and others to improve productivity and product quality. The other new techniques include systems to pursue reliability and maintainability, in which electric appliances, instruments and computers are integrated, or equipped with built-in large-capacity inverters and drivers. For hot rolling, the above techniques lead to development of a new ...

1996-06-01

27

Advanced Neutron Source: Plant Design Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) ...

1990-07-01

28

Regulatory requirements for design of safety related computer based control Systems in Indian PHWRs: case study of DPHS-PCS for TAPP-3 and 4  

International Nuclear Information System (INIS)

Computer based control systems for safety related applications in nuclear power plants have to meet not only the functional, performance and interface requirements, they in addition, have to meet regulatory requirements like enhanced reliability, safety and security and should provide fault tolerance, diagnostics and self-supervision. The control system architecture, hardware design and software design should meet requirements as specified in design code and guides of AERB. The Dual Processor Hot Standby Process Control System (DPHS-PCS) for TAPP-3 and 4 is a safety related (Class- IB) system. DPHS-PCS regulates PHT pressure, Pressuriser pressure, Pressuriser level, Bleed condenser pressure, Bleed condenser level and Steam generator pressure. The performance, reliability and safety requirements of this control ...

2005-03-01

29

Naval Sea Systems Command occupational safety and health record-keeping system. Hazardous Materials Control Module. Program maintenance manual  

Energy Technology Data Exchange (ETDEWEB)

Since August 1984, the MITRE Corporation has been supporting the Naval Sea Systems Command (NAVSEA) and the Naval Medical Command (NAVMEDCOM) in their joint efforts to enhance the Navy Occupational Health Information Management System (NOHIMS). The goal of the enhancement effort was to create a comprehensive occupational health and safety system for Navy industrial facilities by expanding upon the original NOHIMS functions and adding modules for hazard deficiency abatement, hazardous-material control, injury claims and compensation, and safety and health training. To meet this goal, MITRE developed an enhanced industrial subsystem, referred to as the Occupational Safety and Health Record Keeping System (OSHRKS), using a prototyping approach and a public-domain data base-management software package, the Veterans Administration's (VA's) ...

1987-06-01

30

Proceedings of national conference on operating experience of nuclear reactors and power plants: book of preprints  

International Nuclear Information System (INIS)

The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)

2006-11-13

31

A modular and extensible data acquisition and control system for testing superconducting magnets  

Energy Technology Data Exchange (ETDEWEB)

The Magnet Test Facility at Fermilab tests a variety of full-scale and model superconducting magnets for both R and D and production. As the design characteristics and test requirements of these magnets vary widely, the magnet test stand must accommodate a wide range of Data Acquisition (DAQ) and Control requirements. Such a system must provide several functions, which includes: quench detection, quench protection, power supply control, quench characterization, and slow DAQ of temperature, mechanical strain gauge, liquid helium level, etc. The system must also provide cryogenic valve control, process instrumentation monitoring, and process interlock logic associated with the test stand. A DAQ and Control system architecture that provides the functionality described above has been designed, fabricated, and put into ...

2001-07-20

32

B Plant treatment, storage, and disposal (TSD) units inspection plan  

Energy Technology Data Exchange (ETDEWEB)

This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under ...

1996-04-26

34

System control and data acquisition of the two new FWCD RF systems at DIII-D  

Energy Technology Data Exchange (ETDEWEB)

The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main ...

1995-10-01

35

Comparison of the Standards applied to Instrumentation and Control Systems for Nuclear Power Stations in Korea and Russia  

Energy Technology Data Exchange (ETDEWEB)

This report describes a comparison result of technical standards applied to instrumentation and control systems for nuclear power plants between in Korea and in Russia. Russia also has a state-run organization authorized to conduct approval, cancellation, and audit in use of nuclear facility or equipment. The Russian standards for nuclear instrumentation and control equipment are analogous with the Korean ones in the aspect of basic concepts and principles. However, there are some differences in document structure, design requirements, qualification test items, depth of contents between two standard systems. The biggest deviation exists in the standard documents for seismic qualification and electromagnetic interference qualification. Korean seismic qualification standard utilizing US approach, defines testing and qualification methods specifically and clearly. Russian standards ...

2005-04-15

36

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

37

Increased capability of Strassy: the decision making aid for the inspection of nuclear materials; Prolongement des capacites de Strassy: systeme d`aide a la decision pour le controle des matieres nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The paper describes the latest developments in STRASSY (Strategy Assistance System), the strategy assistance system for the inspection of nuclear materials. The user can now select the fuel cycle he wishes to investigate from an initial range of 19 facilities. An inspection interface has been developed to enable the details and dates of inspections to be modified. One of the special features of the application of STRASSY in international safeguards is the taking into account of timeliness of detection; certain aspects of the time manager algorithms are presented and analysed, including the guaranteed existence of a solution. The results of a study of diversion paths in a simplified cycle consisting of our facilities are presented. Finally, the modifications necessary to enable STRASSY to be used for a posterior analysis of inspection results are discussed. (authors). 7 refs., 3 figs.

1994-12-31

38

The full scope simulator hardware I/O realization in Daya bay nuclear power station  

International Nuclear Information System (INIS)

The full scope simulator in Daya Bay Nuclear Power Station is imported from THOMSON-CSF company in France. It is a large facility, using digital simulation technology, that simulate the main control room of Daya Bay Nuclear Power Station with the high fidelity. It is used for training operators; system analyzing including operation procedure verification. The input output interface system of the simulator is the bridge of the information exchange between instrumentation and the computer. From the point of view of data transfer, this paper discusses the operation principle of the I/O interface system.

39

Demonstration experiment on improved radwaste evaporator  

Energy Technology Data Exchange (ETDEWEB)

High conductivity liquid waste, which is produced in nuclear power plants, is now processed with radwaste evaporator. The concentrated liquid waste in the evaporator is so highly radioactive and corrosive that the improvement on maintenability and reduction of exposure dose rate are desirable as well as high decontamination factor (DF). Fuji Electric constructed the improved experimental facility of evaporator and carried out an experiment to demonstrate DF, maintenability and controllability of system. As the results, DF, maintenability and controllability were proved to be excellent and its applicability to nuclear power plant was well established.

1988-07-01

40

Citizen involvement in radiological monitoring in their environment  

Energy Technology Data Exchange (ETDEWEB)

This paper is intended to describe how the citizens who are living near power plants or more generally nuclear facilities can be involved in the radiological control of their environment. Through the experience of the last twenty years, the article describes the conditions of the progressive setting up of a non- governmental system of control to build its principles of action and put them into practice. Three kinds of actions are described, the first two dealing with the problems in France and the last one related to a post-accidental situation in the contaminated areas of Belarus. The conclusion underlines how important it is to encourage this kind of involvement in order to increase public awareness of nuclear activities and their consequences. (authors)

2005-07-01

41

Work plan for the Isotopes Facilities Deactivation Project at Oak Ridge National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the Isotopes Facilities Deactivation Project (IFDP) is to place former isotopes production facilities at the Oak Ridge National Laboratory in a safe, stable, and environmentally sound condition; suitable for an extended period of minimum surveillance and maintenance (S&M) and as quickly and economical as possible. Implementation and completion of the deactivation project will further reduce the risks to the environment and to public safety and health. Furthermore, completion of the project will result in significant S&M cost savings in future years. The IFDP work plan defines the project schedule, the cost estimate, and the technical approach for the project. A companion document, the IFDP management plan, has been prepared to document the project objectives, define organizational relationships and responsibilities, and outline the management control systems to be employed in the ...

1995-05-01

42

Environmental control for machine shops  

Energy Technology Data Exchange (ETDEWEB)

Metal machining facilities pose interesting design problems. This article provides an overview of key environmental control considerations and ways to deal with them. Machine shops offer a variety of environmental control challenges to mechanical engineers. Among the design problems that must be considered include: whether to provide space heating only or year-round air conditioning; temperature and relative humidity requirements; air cleanliness; exhaust air requirements; the type of HVAC system to be used; industrial waste and plumbing considerations; compressed air needs; and noise control. In addition, the designer must comply with worker health and safety and environmental protection regulations set forth by the National Institute of Safety and Health (NIOSH), OSHA, and EPA, as well as with any applicable state and local requirements.

1994-04-01

43

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by ...

1994-09-01

44

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period January 1, 2005 through March 31, 2005. The following tasks have been completed. First, the renovation of the new Combustion Laboratory is nearly complete, and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building is in the final stages. Second, the fabrication and manufacture of the CFBC Facility is being discussed with a potential contractor. Discussions with potential contactor regarding the availability of materials and current machining capabilities have resulted in the modification of the original designs. The selection of the fabrication contractor for the CFBC Facility is expected during the next quarter. Third, co-firing experiments ...

2005-04-30

45

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and ...

1982-12-01

46

Randomized Algorithms for Analysis and Control of Uncertain Systems  

CERN Document Server

Randomized Algorithms for Analysis and Control of Uncertain Systems

2005-01-01

47

Multi-Harmonic RF Control System for J-PARC RCS  

CERN Document Server

Multi-Harmonic RF Control System for J-PARC RCS

2003-01-01

48

Input-output stability for accelerometer control systems  

Science.gov (United States)

It is shown that, although accelerometer control systems are not well-posed in the sense of Salamon,

1991-01-01

49

Industrial HVAC: a survey of design considerations  

Energy Technology Data Exchange (ETDEWEB)

Industrial facilities offer a wide variety of design challenges to engineers, including the mechanical engineers who design the HVAC, the process, exhaust, and other required mechanical systems; the mechanical contractors who install and maintain the systems (and who also may do design work); and the owners` engineers who are responsible for the day-to-day operation of their facilities. Along with the responsibility to see that all systems function as intended is the responsibility to ensure that all worker health concerns are addressed. These include heat stress avoidance and the proper control of harmful substances. The services of industrial hygienists may be required to ensure this. These may be independent consultants or the staff members of mechanical design firms. In addition, it is not unusual for major corporations that own manufacturing plants to have ...

1996-11-01

50

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This purpose of this report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period April 1, 2005 through June 30, 2005. The following tasks have been completed. First, the new Combustion Laboratory was occupied on June 15, 2005, and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building is in the final painting stage. Second, the fabrication and manufacturing contract for the CFBC Facility was awarded to Sterling Boiler & Mechanical, Inc. of Evansville, Indiana. Sterling is manufacturing the assembly and component parts of the CFBC system. The erection of the CFBC system is expected to start September 1, 2005. Third, mercury emissions from the cofiring of coal and chicken waste was ...

2005-07-30

51

The uses of system integration. In the field of tension between building safety and automation; Nutzen der Systemintegration. Im Spannungsfeld von Gebaeudesicherheit und Gebaeudeautomation  

Energy Technology Data Exchange (ETDEWEB)

There are no 'intelligent' buildings but only 'intelligently controlled' buildings. Intelligent control requires communication between technical facilities, which in turn requires building automation and system integration. [German] Es gibt keine ''intelligenten'', sondern nur ''intelligent betriebene'' Gebaeude. Mit dieser Feststellung ist die Vorbedingung festgelegt, dass Gebaeude ein gewerkeuebergreifendes System benoetigen, das die Komponenten miteinander kommunizieren laesst. Dafuer eignet sich die Gebaeudeautomation. Damit diese ihre Aufgaben erfuellen kann, bedarf es der Systemintegration. (orig.)

2001-07-01

52

Power Systems Development Facility Gasification Test Campaign TC17  

Energy Technology Data Exchange (ETDEWEB)

In support of technology development to utilize coal for efficient, affordable, and environmentally clean power generation, the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama, routinely demonstrates gasification technologies using various types of coals. The PSDF is an engineering scale demonstration of key features of advanced coal-fired power systems, including a KBR (formerly Kellogg Brown & Root) Transport Gasifier, a hot gas particulate control device, advanced syngas cleanup systems, and high-pressure solids handling systems. This report summarizes the results gasification operation with Illinois Basin bituminous coal in PSDF test campaign TC17. The test campaign was completed from October 25, 2004, to November 18, 2004. System startup and initial operation was accomplished with Powder River Basin (PRB) ...

2004-11-30

53

FFTF fission gas monitor computer system  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for ...

54

Measures for reliability improvement of on-site power plant at steel works  

Energy Technology Data Exchange (ETDEWEB)

This report describes the arrangement and features of the Ogishima thermal power plant facilities, as well as activities being performed there for operation control, regular inspection and improvement in reliability. The power plant uses about 48 percent of the by-product gas as its fuel to supply about 81 percent of the required power. Operation of the No. 1 unit started in 1976. Currently, the plant has three units, each with an output of 125MW. Each unit consists of a natural circulation boiler with a maximum evaporation capacity of 410 ton/hour and a reheat regenerative condensing turbine with a main vapor pressure of 127 kg/cm/sup 2/G. Techniques used for water properties control and combustion control are also described. In the plant, convetional time management integrity techniques are now being replaced by state management integrity techniques that determines the deterioration tendency in ...

1988-04-15

55

An outline of the fuelling machine electrical instrumentation and controls  

International Nuclear Information System (INIS)

An outline of the instrumentation and control systems associated with fuelling machines is given. The control systems such as hydraulic system, oil hydraulic system, electric control system and the remote control systems have been discussed in detail. The difference between RAPP and MAPP fuel handling control systems has been explained. A computer based system for the Narora fuel handling control system is also discussed. (S.K.K.).

56

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).

1985-02-01

57

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.

1985-02-01

58

Interim safety basis for fuel supply shutdown facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB in conjunction with the new TSRs, will provide the required basis for interim operation or restrictions on interim operations and administrative controls for the Facility until a SAR is prepared in accordance with the new requirements. It is concluded that the risk associated with the current operational mode of the Facility, uranium closure, clean up, and transition activities required for permanent closure, are within Risk Acceptance Guidelines. The Facility is classified as a Moderate Hazard Facility because of the potential for an unmitigated fire associated with the uranium storage buildings.

1995-05-23

59

Theory and evidence of economies of scale in the development of waste management systems  

Energy Technology Data Exchange (ETDEWEB)

Waste is a cost of doing business. This cost can be considered in terms of the potential adverse health and environmental impacts, or the waste management costs associated with avoiding, minimizing, and controlling those impacts. There is an anticipated increase in the cost of waste management as a result of the increasing requirements for regulatory compliance. To meet the total waste management capacity needs of the organization and the compliance requirements, low-level radioactive, hazardous, and mixed waste management will need demonstrated technologies strategically managed as a technology portfolio. The role of the decision maker is to select the optimum mix of technologies and facilities to provide the waste management capacity needed for the next twenty years. The waste management system resulting from this mix includes multiple small-scale fixed facilities, large-scale centralized ...

1989-01-01

60

Advanced Neutron Source: Plant Design Requirements. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) ...

1990-07-01

61

Use of selective catalytic reduction for control of NO{sub x} emissions from power plants  

Energy Technology Data Exchange (ETDEWEB)

This report describes selective catalytic reduction (SCR) technologies which offer an economical and effective means of reducing nitrogen oxide emissions from electricity generation facilities and reviews the feasibility and cost effectiveness of employing this technology on electricity generating facilities in Ontario. Based on experiences in the United States, in British Columbia, and internationally in Japan and Germany, the indication is that the technology for the installation of SCR systems on new gas-fired combined cycle power plants and existing coal-fired power plants has grown enormously during the past decade, and has been established as the control technology of choice for nitrogen oxide emissions. It is widely acknowledged to reduce power plant nitrogen oxide emissions, and do so at a very reasonable incremental cost. It is estimated that the annualized cost of installing and operating a ...

1999-07-01

62

Federal Facility Agreement plans and schedules for liquid low-level radioactive waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank ...

1992-03-01

63

Automated real-time testing (ARTT) for embedded control systems (ECS).  

Energy Technology Data Exchange (ETDEWEB)

Many of today's automated real-time testing systems for embedded systems were developed using expensive custom hardware and software. In this article they describe how to use commercially available off-the-shelf hardware and software to design and develop an automated real-time test systems for Embedded Programmable Logic Controller (PLC) Based Control Systems. The system development began with the implementation of the VALI/TEST Pro testing methodology as a means for structuring the testing. Using this methodology, they were able to decompose system requirement documents for a Personnel Safety System (PSS) into its high, intermediate and detail level requirements. next, the validation procedures for the PSS system were decomposed into testing units called builds, test ...

2001-08-09

64

Integrative facility management via the intranet requires reliable communication. Network and security solutions for multi-site facility management; Integratives Gebaeudemanagement ueber Intranet erfordert gesicherte Kommunikation. Network und Security Konzept fuer das technische Multi-Site-Facility-Management  

Energy Technology Data Exchange (ETDEWEB)

Since enterprises operating offices and facilities at geographically distributed sites have been establishing an intranet for inter-office communication at the management level, the idea of integrating another intranet for multi-site technological facility management comes naturally. The Aachen-based technology enterprise Eurem for this purpose developed a Network and Security concept with solutions that can be customized for linking a variety of computerized control and monitoring systems. The package includes a modular substation named modUS, which is open to the field side as well as to the management side, is capable of efficiently and reliably performing the facility management functions by way of remote controlling via intranets. (orig./CB) [Deutsch] Nachdem in den Unternehmen mit verteilten Liegenschaften die unterschiedlichsten Buerokommunikationssysteme ...

1999-02-08

65

Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated ...

2007-08-01

66

ESTABLISHMENT OF AN ENVIRONMENTAL CONTROL TECHNOLOGY LABORATORY WITH A CIRCULATING FLUIDIZED-BED COMBUSTION SYSTEM  

Energy Technology Data Exchange (ETDEWEB)

This report is to present the progress made on the project ''Establishment of an Environmental Control Technology Laboratory (ECTL) with a Circulating Fluidized-Bed Combustion (CFBC) System'' during the period October 1, 2004 through December 31, 2004. The following tasks have been completed. First, the renovation of the new Combustion Laboratory and the construction of the Circulating Fluidized-Bed (CFB) Combustor Building have proceeded well. Second, the detailed design of supporting and hanging structures for the CFBC was completed. Third, the laboratory-scale simulated fluidized-bed facility was modified after completing a series of pretests. The two problems identified during the pretest were solved. Fourth, the carbonization of chicken waste and coal was investigated in a tube furnace and a Thermogravimetric Analyzer (TGA). The experimental results from this study are presented in ...

2005-01-30

67

New developments in dry spent fuel storage  

International Nuclear Information System (INIS)

As shown in various new examples, HABOG facility (Netherlands), CERNAVODA (Candu - Romania), KOZLODUY (WWER - Bulgaria), CHERNOBYL ( RMBK - Ukraine), MAYAK (Spent Fuel from submarine and Icebreakers - Russia), recent studies allow to confirm the flexibility and performances of the CASCAD system proposed by SGN, both in safety and operability, for the dry storage of main kinds of spent fuel. The main features are: A multiple containment barrier system: as required by international regulation, 2 independent barriers are provided (tight canister and storage pit); Passive cooling, while the Fuel Assemblies are stored in an inert atmosphere and under conditions of temperature preventing from degradation of rod cladding; Sub-criticality controlled by adequate arrangements in any conditions; Safe facility meeting ICPR 60 Requirements as well as all applicable regulations (including severe ...

2001-06-18

68

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during ...

69

Durability of Defense Waste Processing Facility glasses within the Purex range of compositions  

Energy Technology Data Exchange (ETDEWEB)

Processing in the Defense Waste Processing Facility (DWPF) is controlled by constraints on predicted properties of the product glass. One of these properties is chemical durability, which is measured as the response of various glass constituents to the seven-day Product Consistency Test (PCT) [1]. As currently implemented into the DWPF`s Product Composition Control System (PCCS) the response of boron is taken as representative of all of the constituent responses, and control is in terms of the boron response. This response, in normalized units and in log scale, is taken to be a linear function of the glass`s free energy of hydration, {Delta}G. {Delta}G is a parameter which represents the sum of influences on durability of the various glass oxide components. A generalized relationship between these two variables is documented in [2]. This relationship appears to underpredict releases ...

1995-05-01

70

FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system ...

71

Modeling, Simulation Design and Control of Hybrid-Electric Vehicle Drives  

Energy Technology Data Exchange (ETDEWEB)

Ohio State University (OSU) is uniquely poised to establish such a center, with interdisciplinary emphasis on modeling, simulation, design and control of hybrid-electric drives for a number of reasons, some of which are: (1) The OSU Center for Automotive Research (CAR) already provides an infrastructure for interdisciplinary automotive research and graduate education; the facilities available at OSU-CAR in the area of vehicle and powertrain research are among the best in the country. CAR facilities include 31,000 sq. feet of space, multiple chassis and engine dynamometers, an anechoic chamber, and a high bay area. (2) OSU has in excess of 10 graduate level courses related to automotive systems. A graduate level sequence has already been initiated with GM. In addition, an Automotive Systems Engineering (ASE) program cosponsored by the mechanical and electrical engineering programs, ...

2005-09-30

72

Pacific Northwest Laboratory FY 1993 Site Maintenance Plan for maintenance of DOE nonnuclear facilities  

Energy Technology Data Exchange (ETDEWEB)

This Site Maintenance Plan has been developed for Pacific Northwest Laboratory's (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; ...

1992-09-28

73

Pacific Northwest Laboratory FY 1993 Site Maintenance Plan for maintenance of DOE nonnuclear facilities  

Energy Technology Data Exchange (ETDEWEB)

This Site Maintenance Plan has been developed for Pacific Northwest Laboratory`s (PNL) Nonnuclear Facilities. It is based on requirements specified by US Department of Energy (DOE) Order 4330.4A, Chapter I, Change No. 4. The objective of this maintenance plan is to provide baseline information for compliance to the DOE Order 4330.4A, to identify needed improvements, and to document the planned maintenance budget for Fiscal Year (FY) 1993 and to estimate maintenance budgets for FY 1994 and FY 1995 for all PNL facilities. Using the results of the self-assessment, PNL has selected 12 of the 36 elements of the Maintenance Program defined by DOE Order 4330.4A, Chapter I, for improvement. The elements selected for improvement are: Facility Condition Inspections; Work Request (Order) System; Formal Job Planning and Estimating; Work Performance (Time) Standards; Priority System; Maintenance ...

1992-09-28

74

The operation status and prospect of radioisotope production facility in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power ...

2008-11-15

75

Using the in-house telephone network for language storage purposes as additional information facility. Nutzung des Werkstelefonnetzes fuer Sprachspeicherdienste als zusaetzliche Informationseinrichtung  

Energy Technology Data Exchange (ETDEWEB)

As a first step an attempt was made to integrate a personnel information facility into a system for optimising materials flow. The two systems developed did not reach a workable stage because the synthetic language would have required an input on the part of the personnel operating the system beyond what could reasonably be expected. The research in the second stage consisted in developing and testing a module with which language storage services could be built up on the basis of digitalised speech and controlled via the in-house telephone network. In language storage services users may feed in data or interrogate. Services of this kind can readily be integrated into available telephone installations working on the pulse selection principle. The low cost of the hardware involved means the system can be built up with modest investment while offering high ...

1990-06-01

76

Fluidic-controlled automatic rabbit system  

International Nuclear Information System (INIS)

... v. 15(10) p. 445-449. automation control equipment fluid flow fluidic control

77

Fluidic shut-down system for a nuclear reactor  

International Nuclear Information System (INIS)

... fluid poison control fluidic control devices reactors scram scram rods control

78

Interim Safety Basis for Fuel Supply Shutdown Facility  

Energy Technology Data Exchange (ETDEWEB)

This ISB, in conjunction with the IOSR, provides the required basis for interim operation or restrictions on interim operations and administrative controls for the facility until a SAR is prepared in accordance with the new requirements or the facility is shut down. It is concluded that the risks associated with tha current and anticipated mode of the facility, uranium disposition, clean up, and transition activities required for permanent closure, are within risk guidelines.

2000-09-07

79

Power fluidics for ventilation control  

International Nuclear Information System (INIS)

... amplification exhaust systems fluidic control devices gloveboxes pressure

1984-11-28

80

Fluidic programmer for nuclear engine application  

International Nuclear Information System (INIS)

... fluidic control devices performance reactor control systems space propulsion

84

Registration of Hanford Site Class V underground injection wells  

Energy Technology Data Exchange (ETDEWEB)

This document was requested by the Washington State Department of Ecology. Based on the State Underground Injection Control Program, as described in the Washington Administrative Code, French drains and reverse wells are being registered as Class V wells. Information on out-of-service French drains, out-of-service reverse wells, and out-of-service cribs that are deeper than their largest surface dimension is also provided. The data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. The facilities listed in WIDS as inactive have all been listed as ''out-of-service.'' Information concerning the deactivation ...

1988-05-01

85

Plutonium Finishing Plant safety evaluation report  

Energy Technology Data Exchange (ETDEWEB)

The Plutonium Finishing Plant (PFP) previously known as the Plutonium Process and Storage Facility, or Z-Plant, was built and put into operation in 1949. Since 1949 PFP has been used for various processing missions, including plutonium purification, oxide production, metal production, parts fabrication, plutonium recovery, and the recovery of americium (Am-241). The PFP has also been used for receipt and large scale storage of plutonium scrap and product materials. The PFP Final Safety Analysis Report (FSAR) was prepared by WHC to document the hazards associated with the facility, present safety analyses of potential accident scenarios, and demonstrate the adequacy of safety class structures, systems, and components (SSCs) and operational safety requirements (OSRs) necessary to eliminate, control, or mitigate the identified hazards. Documented in this Safety Evaluation Report (SER) is DOE`s independent ...

1995-01-01

86

Decontamination of nuclear facilities  

International Nuclear Information System (INIS)

Thirty-seven papers were presented at this conference in five sessions. Topics covered include regulation, control and consequences of decontamination; decontamination of components and facilities; chemical and non-chemical methods of decontamination; and TMI decontamination experience.

1982-09-19

87

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

88

Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)  

Energy Technology Data Exchange (ETDEWEB)

The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to ...

2007-07-01

89

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at ...

2007-05-07

90

FFTF operations: initial operator training simulator program  

International Nuclear Information System (INIS)

This paper describes the Fast Flux Test Facility (FFTF) Operations initial training program utilizing the Operator Training Simulator (OTS). The OTS is a computer-driven system that provides real time response of essential FFTF plant functions to a control room mockup. The FFTF, a 400 Megawatt, three-loop, sodium-cooled fast test reactor will test fuels, materials and equipment for the U.S. Liquid Metal Fast Breeder Reactor Program. Construction is expected to be completed in August 1978. Initial criticality is expected in early 1979. This schedule will require FFTF control room operators to be fully qualified to operate the facility by late 1979. Because FFTF is like no other U.S. nuclear reactor, existing U.S. utility plants could not be depended on to provide highly experienced people to operate FFTF. Therefore, an Operator Training Simulator has been built. The OTS will play a ...

91

Distributed radiation protection console system  

International Nuclear Information System (INIS)

Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area ...

2004-02-01

92

TPX Neutral Beam Injection System design  

International Nuclear Information System (INIS)

The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to ...

1993-10-11

93

Automated Critical Peak Pricing Field Tests: Program Descriptionand Results  

Energy Technology Data Exchange (ETDEWEB)

California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have ...

2006-04-06

94

The Oak Ridge Y-12 Plant biological monitoring and abatement program for East Fork Poplar Creek  

Energy Technology Data Exchange (ETDEWEB)

In May 1985, a National Pollutant Discharge Elimination System permit was issued for the Oak Ridge Y-12 Plant, a nuclear weapons components production facility located in Oak Ridge, Tennessee, and operated by Martin Marietta Energy Systems, Inc., for the US Department of Energy. As a condition of the permit, a Biological Monitoring and Abatement Program (BMAP) was developed to demonstrate that the effluent limitations established for the Oak Ridge Y-12 Plant protect the classified uses of the receiving stream (East Fork Poplar Creek), in particular, the growth and propagation of fish and aquatic life, as designated by the Tennessee Department of Health and Environment. A second purpose for the BMAP is to document the ecological effects resulting from implementation of a water pollution control program that will include construction of nine new wastewater treatment facilities over ...

1989-10-01

95

An Experimental Apparatus Proposed for Efficient Removal of Isobaric Contaminants in Negative Ion Beams  

Energy Technology Data Exchange (ETDEWEB)

Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the ...

2008-09-01

96

Test facilities for hybrid and electric drive trains; Stazione di prova sistemi di trazione ibridi ed elettrici  

Energy Technology Data Exchange (ETDEWEB)

ENEA (Italian National Agency for New Technologies, Energy and the Environment) is conducting a large research and development programme on innovative vehicles with high energy efficiency and low environmental impact. In particular conducts activities on electric and hybrid vehicles. Testing and evaluation activities play a strong role in this programme. A complete characterization chain has been then defined and set up with a network of facilities which covers main testing needs for single components, subsystems and complete vehicles, in simulated and real operating conditions. The test facility which has been realised is able to experiment and fully characterise complete drive-trains (and subsystems) for pure electric and hybrid vehicles. It is composed by a different section for each subsystem: 1) power generation; 2) energy storage and management; 3) driving motors. Each section acts as an experimental island, able to operate alone or ...

1998-12-31

97

PowerPoint Presentation  

Wastenet

facilities, building hygienic latrines and introducing regular solid waste collection systems . These methods are constantly being developed and

99

The BPX electrical power system  

International Nuclear Information System (INIS)

This paper reports on the Burning Plasma Experiment (BPX) which when operating at a toroidal field of 8.1 tesla and a plasma current of 10.6 megamps, requires peak power of 1235 megawatts and total pulse energy of over 21 gigajoules. These requirements are twice and over four times the corresponding figures for the Tokamak Fusion Test Reactor (TFTR), respectively. The design of the BPX power system has evolved, along with the tokamak, over a period of several years and has included studies of several alternative approaches. The reapplication of the existing TFTR power and energy facilities has been basic to all approaches. Among the new sources of pulse power and energy that have been considered are: direct utility grid pulsing, new flywheel units, and lead-acid storage batteries. The toroidal field power requirements are the greatest of the BPX subsystems and, fortunately, are sufficiently free of dynamics to allow the consideration of all ...

1991-10-03

100

Lower Flathead System Fisheries Study, Executive Summary, Volume I, 1983-1987 Final Report.  

Energy Technology Data Exchange (ETDEWEB)

This Executive Summary, Volume I, of the lower Flathead System Fisheries Study Final Report, was prepared to provide a study overview for persons who are not fisheries scientists. The contents provide an introduction to the study and its objectives, a short description of the study area, a discussion of the major findings and conclusions of the study, and the description of fisheries management alternatives available to managers of the lower Flathead system. Technical reports were prepared for those portions of the study dealing with the lower Flathead River and its tributaries, Volume II, and the South Bay of Flathead Lake, Volume III. The annual hydrographic regime of the Flathead system, consisting of upper rivers, lake and lower river, has been modified by the construction and operation of two major hydroelectric facilities, Hungry Horse Dam on the south fork Flathead River and Kerr Dam at the ...

1988-06-01

101

Topical Report ''Corrosion Evaluation of LLW2 Skid-B Weld Failure Mechanisms (44139-92)  

Energy Technology Data Exchange (ETDEWEB)

An independent investigation of pipe welding leaks from the Low-Level Waste 2 (LLW2) Skid-B System for the possibilities of improper welding (IW), microbiologically influenced corrosion (MIC), sensitization, chloride pitting corrosion (CPC), and intergranular stress corrosion cracking (IGSCC) was conducted. The results show the prevailing mechanisms that caused the leaks are identified as IW, CPC, and the improper selection of weld filler material for the base metals in an environment of the North Plateau underground water. These is no evidence of MIC, sensitization, or IGSCC. The chloride pitting corrosion mechanism that took place at all the welds are also described. All the pipelines were replaced with polyvinyl chloride (PVC) for cost saving and the LLW2 Skid B System has been successfully operating since 1999. This report summarizes the findings and recommendations associated with preventive measures for future operations. The LLW2 ...

2001-05-31

102

LOOP Inc. (Louisiana Offshore Oil Port Inc. ) to start onshore construction this year  

Science.gov (United States)

A discussion covers the LOOP project to construct an offshore pipeline system, which will connect with onshore facilities at Fourchon, La., and two onshore pipelines (26 mi 48 in. Clovelly line and 53 mi 48 in. LOCAP line) connecting Fourchon with the existing Capline system at St. James, La.; the three-phase construction schedule, the first phase due to begin in the third quarter of 1978 with, e.g., onshore pipeline and salt dome storage facility construction which will yield an expected initial throughput of 1.4 million bbl/day; the marine terminal complex, consisting of control and pumping platforms, and three 7000 hp pumps to operate the system at 45,000-100,000 bbl/hr; the offshore lines, including lines between single-point mooring units and the pumping platform, the 21 mi 48 in. pipe to Fourchon, and corrosion protection of lines by an asphalt-sand ...

1978-06-01

103

The controllability analysis of the purification system for heavy water reactors  

International Nuclear Information System (INIS)

The heavy water reactor such as Wolsung No.1 and No.2 has a purification system to purify the reactor coolant. The control system regulates the coolant temperature to protect the ion exchanger. After the fuel exchanges of operating plant, the increase of the coolant pressure makes the purification temperature control difficult. In this paper, the controllability of the control dynamics of the purification system was analysed and the optimal parameters were proposed. To reduce the effects of the flow disturbance, the feedforward control structure was proposed and analysed.

2001-10-01

104

Estimates of Amplitudes of Transient Regimes in Quasi-Controllable Discrete Systems  

CERN Document Server

Families of regimes for discrete control systems are studied possessing a special quasi-controllability property that is similar to the Kalman controllability property. A new approach is proposed to estimate the amplitudes of transient regimes in quasi-controllable systems. Its essence is in obtaining of constructive a priori bounds for degree of overshooting in terms of the quasi-controllability measure. The results are applicable for analysis of transients, classical absolute stability problem and, especially, for stability problem for desynchronized (asynchronous, switching) systems.

2009-01-01

105

Controllable Subspaces of Open Quantum Dynamical Systems  

International Nuclear Information System (INIS)

This paper discusses the concept of controllable subspace for open quantum dynamical systems. It is constructively demonstrated that combining structural features of decoherence-free subspaces with the ability to perform open-loop coherent control on open quantum systems will allow decoherence-free subspaces to be controllable. This is in contrast to the observation that open quantum dynamical systems are not open-loop controllable. To a certain extent, this paper gives an alternative control theoretical interpretation on why decoherence-free subspaces can be useful for quantum computation.

2008-01-15

106

Validation of reactor core protection system  

International Nuclear Information System (INIS)

Reactor COre Protection System (RCOPS), an advanced core protection calculator system, is a digitized one which provides core protection function based on two reactor core operation parameters, Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD). It generates a reactor trip signal when the core condition exceeds the DNBR or LPD design limit. It consists of four independent channels adapted a two-out-of-four trip logic. System configuration, hardware platform and an improved algorithm of the newly designed core protection calculator system are described in this paper. One channel of RCOPS was implemented as a single channel facility for this R and D project where we performed final integration software testing. To implement custom function blocks, pSET is used. Software test is performed by two methods. The first method is a 'Software Module Test' and the ...

2008-10-13

107

Neptunium storage at Hanford  

Energy Technology Data Exchange (ETDEWEB)

A decision must be made regarding whether the United State`s stockpile of neptunium should be discarded into the waste stream or kept for the production of Pu-238. Although the cost of long term storage is not inconsequential, to dispose of the material means the closing of our option to maintain control over our Pu-238 stockpile. Within the Fuels and Materials Examination Facility at Hanford there exists a remotely operated facility that can be converted for neptunium storage. This paper describes the facility and the anticipated handling requirements.

1993-06-01

108

Controlling federal costs for coal liquefaction program hinges on management and contracting improvements  

Science.gov (United States)

GAO's review of the H-Coal and Exxon projects showed inadequacies in DOE's contracting practices and a failure by DOE to properly plan, manage, and monitor, especially the H-Coal project. The initial Government-industry H-Coal agreements regarding the level of investment by private sponsors and the ceilings imposed on sharing in cost growth were imbalanced. Larger investments by private sponsors and sharing of cost growth provides an incentive to private sponsors to control costs and helps to assure that each party is fully committed to the success of the project. DOE started the H-Coal project prematurely before sufficiently detailed designs were available and without adequate project planning for functions such as construction scheduling, materials handling, inventory systems, and quality control. DOE staffing was inadequate at both projects to effectively monitor progress and contribute to timely ...

1981-02-04

109

Instrumentation/control systems for small- to medium-size steel-making plants; Tekko setsubi chusho plant no keisoku seigyo system  

Energy Technology Data Exchange (ETDEWEB)

Fuji Electric has realized highly reliable and functional control systems by the dispersion type control system FOCUS, which uses the controller (ICS-2000) enjoying good reputation in controlling industrial plants for a long time and a personal computer with high windows operability, the former for controlling and the latter for MHI responsible for monitoring. The smelting process in a steel-making plant needs a highly reliable system for advanced control to ensure continuous operation. Fuji Electric delivered the FOCUS system to Kubota in 1998, as the smelting furnace instrumentation/control system for the cupola furnace. The system has been in service smoothly. Moreover, a total of four control ...

1999-01-10

110

Quality assurance requirements for control of procurement items and services for nuclear fuel reprocessing facilities  

International Nuclear Information System (INIS)

Requirements and guidelines are provided for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear facilities. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storing, cleaning, constructing, erecting, installing, inspecting, texting, maintaining and modifying.

111

Cold Vacuum Drying (CVD) Facility Technical Safety Requirements  

Energy Technology Data Exchange (ETDEWEB)

The Technical Safety Requirements (TSRs) for the Cold Vacuum Drying Facility define acceptable conditions, safe boundaries, bases thereof, and management or administrative controls required to ensure safe operation. Controls required for public safety, significant defense-in-depth, significant worker safety, and for maintaining radiological and toxicological consequences below risk evaluation guidelines are included.

1999-12-16

112

Production and remediation of low-sludge, simulated Purex waste glasses, 1: Effects of sludge oxide additions on melter operation  

Energy Technology Data Exchange (ETDEWEB)

Glass produced during the Purex 4 campaigns of the Integrated Defense Waste Processing Facility (DWPF) Melter System (IDMS) and the 774 Research Melter contained a lower fraction of sludge components than targeted by the Product Composition Control System (PCCS). Purex 4 glass was more durable than the benchmark (EA) glass, but less durable than most simulated SRS high-level waste glasses. Also, Purex 4 glass was considerably less durable than predicted by the algorithm which will be used to control production of DWPF glass. A melter run was performed using the 774 Research Melter to determine if the initial PCCS target composition determined for Purex 4 would produce acceptable glass whose durability could be accurately modeled by Hydration Thermodynamics. Reagent grade oxides and carbonates were added to Purex 4 melter feed stock to simulate a higher sludge loading. Each canister ...

1993-07-15

113

Results of the 2nd periodical inspection of the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station  

International Nuclear Information System (INIS)

The 2nd periodical inspection was carried out on the asphalt solidification facility and the incinerator in Unit 2 of the Sendai Nuclear Power Station from November 5 to 28, 1985. Inspection was made in radiation control facility and disposal facility. By external appearance, disassembly, function and performance tests there were observed no abnormalities. The personnel exposure doses during the inspection were below the permissible level. In the inspection, improvement etc. works were not done. (Mori, K.).

1986-01-01

114

Results of regular inspection of No.2 plant in Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from January 7 to February 8, 1985. The summary of the results of this regular inspection is as follows. The facilities as the object of inspection were radiation control facilities and waste facilities. On these facilities as the object of inspection, the appearance, disassembling, functional, performance and other inspections were carried out, and as the results, abnormality was not found at all. The works related to this regular inspection were accomplished within the range of the allowable radiation dose based on the relevant laws. (Kako, I.).

1986-01-01

115

Robust computationally efficient control of cooperative closed-chain manipulators with uncertain dynamics  

British Library Electronic Table of Contents (United Kingdom)

This article presents a decentralized control scheme for the complex problem of simultaneous position and internal force control in cooperative multiple manipulator systems. The proposed controller is composed of a sliding mode control term and a force robustifying term to simultaneously control the payloads position/orientation as well as the internal forces induced in the system. This is accomplished independently of the manipulators dynamics. Unlike most controllers that do not require prior knowledge of the manipulators dynamics, the suggested controller does not use fuzzy logic inferencing and is computationally inexpensive. Using a Lyapunov stability approach, the controller is proven to be robust in the face of varying systems dynamics. The payloads ...

2007-01-01

116

Science & Technology Review July/August 2005  

Energy Technology Data Exchange (ETDEWEB)

This journal contains the following articles (1) The Grand Challenge of Thermonuclear Ignition--Commentary by Edward I. Moses; (2) Orchestrating the World's Most Powerful Laser--The computer control system for the National Ignition Facility will soon have about 1.4-million lines of code running on more than 750 computers; (3) A Randon Walk through Time and Space--Albert einstein's 1905 papers on Brownian motion, random fluctuations, and statistical mechanics are fundamental to many Livermore research projects; (4) The Search for Methane in Earth's Mantle--Scientists are discovering that Earth's mantle may have untapped reserves of methane; and (5) Testing the Physics of Nuclear Isomers--Results from a tri-laboratory project contradict claims of accelerated release of energy from the nuclear isomer hafnium-178.

2005-06-14

117

Hydrogen production in a 5 kW Diesel Oxidative Steam Reformer  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a reformer prototype for the production of the necessary H{sub 2} to supply a 5 kW PEMFC and its first results. The fuel processor consists of an OSR and a WGS and a PROX reactors. The design of the system was carried out with a one-dimensional model. The mixture chamber was specially studied with a CFD code (Fluent), taking into account the effect of fuel evaporation and the cool flame process. The aim of the designed facility is to be able of characterising each component and controlling each working parameter. Eventually, using diesel as fuel, results from the mixture chamber, OSR, WGS and PROX reactors are presented. It also includes conclusions and future works. (authors)

2006-07-01

118

Techno-economic assessment of anaerobic digestion systems for agri-food wastes  

Energy Technology Data Exchange (ETDEWEB)

Activities in British Columbia's Fraser Valley generate an estimated 3 million tones of agriculture and food wastes annually, of which 85 per cent are readily available for anaerobic digestion. The potential for energy generation from biogas through anaerobic digestion is approximately 30 MW. On-farm manure-based systems represent the most likely scenario for the development of anaerobic digestion in British Columbia in the near future. Off-farm food processing wastes may be an alternative option to large centralized industrial complexes. Odour control, pathogen reduction, improved water quality, reduced greenhouse gas emissions and reduced landfill usage are among the environmental benefits of anaerobic digestion. The economical benefits include power and heat generation, biogas upgrading, and further processing of the residues to produce compost or animal bedding. This paper described a newly developed anaerobic digestion (AD) ...

2010-07-01

119

Operation of the Wilsonville Advanced Coal-Liquefaction R and D Facility, Wilsonville, Alabama. Quarterly technical progress report, January-March 1982  

Science.gov (United States)

The first quarter 1982 report summarizes the operating and test data obtained at the six ton per day Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. The Wilsonville R and D Facility was in operation 52% of the period with scheduled shutdowns accounting for 33% of the downtime. Illinois 6 coal from the Burning Star No. 2 mine was processed during Run 236. The three process units of the Wilsonville facility were operated in a non-integrated mode to evaluate process parameters and to test equipment and operating modifications. Data were obtained in the following areas: In the SRC Unit: operation at low severity reaction conditions for single stage liquefaction with a high LSRC recycle rate using Illinois 6 coal; process solvent activity control; and preliminary feeding tests with hydrotreated SRC as a replacement for LSRC in the process solvent. In the CSD Unit: ...

1983-04-01

120

Economic viability of anaerobic digestion  

Energy Technology Data Exchange (ETDEWEB)

The industrial application of anaerobic digestion is a relatively new, yet proven waste treatment technology. Anaerobic digestion reduces and upgrades organic waste, and is a good way to control air pollution as it reduces methane and nitrous gas emissions. For environmental and energy considerations, anaerobic digestion is a nearly perfect waste treatment process. However, its economic viability is still in question. A number of parameters - type of waste (solid or liquid), digester system, facility size, product quality and end use, environmental requirements, cost of alternative treatments (including labor), and interest rates - define the investment and operating costs of an anaerobic digestion facility. Therefore, identical facilities that treat the same amount and type of waste may, depending on location, legislation, and end product characteristics, reveal radically different ...

1996-01-01

121

FY 2000 Feasibility study on the environmentally-friendly coal utilization systems as part of the international project for coal utilization measures. Feasibility study on supporting introduction of the environmentally-friendly coal utilization systems in Vietnam (Model project for introduction of advanced coal preparation systems); 2000 nendo kokusai sekitan riyo taisaku jigyo chosa hokokusho. Kankyo chowagata sekitan riyo system kanosei chosa jigyo Vietnam ni okeru kankyo chowagata sekitan riyo system donyu shien jigyo (kodo sentan system donyu model jigyo kanosei chosa jigyo)  

Energy Technology Data Exchange (ETDEWEB)

The feasibility study was conducted on a model project in Vietnam, aimed at solving the environmental pollution problems resulting from use of coal by demonstrating and disseminating the Japan's environmental technologies in the Southeast Asian countries. The feasibility study was conducted for the Cua Ong Coal Preparation Enterprise, which has the largest coal preparation capacity in Vietnam and port facilities. It is treating raw coal from 10 coal mines for classification and preparation, and shipping coal of various types that meet the standards for domestic use and export. The survey results point out that unrecovered coal remains in waste water discharged from the coal preparation plants to pollute the sea area, and that quantity of the refuse increases because of the unrecovered coal it contains. The environmental technologies needed to introduce include modification to variable wave pattern type jigging separator, refuse height measuring instrument ...

2001-06-01

122

Summary of ACSL Simulations of the MSRE Auxiliary Charcoal Bed Vacuum System  

Energy Technology Data Exchange (ETDEWEB)

The simulation of the Auxiliary Charcoal Bed (ACB) Vacuum System was performed to evaluate the original vacuum system design, detect and identify design deficiencies, investigate the effects of proposed corrections on system performance, and generally aid in refining the system design before construction and mockup testing. The simulation was performed by using the Advanced Continuous Simulation Language (ACSL). The vacuum system design goals are to provide approximately 20 SCFM of both booster gas and purge gas through the system and maintain a flow of approximately 40 SCFM with a velocity of 50 to 75 f/sec at the entrance to the cyclone separator. The model results showed that the original system design was incapable of meeting the system performance goals. Further simulations showed that the following modifications to ...

2000-10-26

123

Advanced Communication and Control for Distributed Energy Resource Integration: Phase 2 Scientific Report  

Energy Technology Data Exchange (ETDEWEB)

The objective of this research project is to demonstrate sensing, communication, information and control technologies to achieve a seamless integration of multivendor distributed energy resource (DER) units at aggregation levels that meet individual user requirements for facility operations (residential, commercial, industrial, manufacturing, etc.) and further serve as resource options for electric and natural gas utilities. The fully demonstrated DER aggregation system with embodiment of communication and control technologies will lead to real-time, interactive, customer-managed service networks to achieve greater customer value. Work on this Advanced Communication and Control Project (ACCP) consists of a two-phase approach for an integrated demonstration of communication and control technologies to achieve a seamless integration of DER units to reach ...

2008-09-30

124

Solar Cogeneration Facility: Cimarron River Station, Central Telephone and Utilities-Western Power. Executive summary  

Energy Technology Data Exchange (ETDEWEB)

A brief overview of the conceptual design of a solar central receiver system integrated with an existing cogeneration facility is provided. A synopsis of the performance and economic evaluation, and an assessment of the concept from the site owner's perspective are given.

1981-08-07

125

OPTIMIZATION OF COMBINED SEWER OVERFLOW CONTROL SYSTEMS  

Science.gov (United States)

The highly variable and intermittent pollutant concentrations and flowrates associated with wet-weather events in combined sewersheds necessitates the use of storage-treatment systems to control pollution.An optimized combined-sewer-overflow (CSO) control system requires a manage...

126

Complete programming documentation for ECIP expansion of existing Energy Monitoring and Control System (EMCS), Fort Leonard Wood, Missouri  

Science.gov (United States)

The objective of this project is to reduce energy consumption in 203 buildings by providing a new EMCS (Energy Monitoring Control System) to control and monitor systems.

1993-12-01

127

Closing the loop In Practice to Assure the Desired Performance  

UK PubMed Central (United Kingdom)

A closed loop control process assures that a system performs within control limits. In closed loop control, the system's output feeds back directly to change the system's inputs. We describe an approach...Full Text Available

2008-01-01

128

Advanced process control technologies for continuous annealing line and galvanizing line; Hakkoban no renzoku shodon oyobi hyomen shori rain no antei tuban gijutsu to koseido hinshitsu seigyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Kawasaki Steel has constructed many facilities for 15 years to produce cold rolled products and galvanized products in Mizushima Works and Chiba Works. To efficiently and stably produce high and uniform quality products, various new control methods have been developed and applied to these new facilities. Especially, temperature control in a continuous annealing line, zinc coating control in a continuous galvanizing line or paint coating control in a multi-purpose coating line and tension control to achieve stable processing are the most advanced technologies and are introduced in this paper. (author)

1999-12-01

129

Criticality experiments: analysis, evaluation, and programs. 6. CORAL-I Reactor: Evaluation of Critical Experiments and Mass Reactivity Coefficient Measurement  

International Nuclear Information System (INIS)

CORAL-I was an experimental, zero-power, fast-spectrum, high-enriched metal uranium reactor that operated from 1968 until 1988 at the former Junta de Energia Nuclear (JEN), CIEMAT at present. The critical measurements performed at the startup of the reactor are being evaluated as part of the International Critical Safety Benchmark Evaluation Program (ICSBEP) and proposed to be included in its 2001 edition. Additionally, the measurement of the mass reactivity coefficient is compared with MCNP4B calculations. This measurement allows one to perform the approach to critical without the need of a previous control rod calibration, thus enhancing the safety of such an approach. This technique can also be applied to other reactor types. CORAL-I (Ref. 1) is a 90% enriched metal uranium reactor domestically designed and manufactured in the experimental facilities of JEN, now CIEMAT, in Madrid, Spain. The enriched uranium was supplied by the International ...

2001-06-17

130

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system  

CERN Document Server

Proposal for the award of a blanket purchase contract for the supply of electronics subracks for the CERN accelerator control system

2010-01-01

131

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

132

Automatic beam position control at Los Alamos Spallation Radiation Effects Facility (LASREF)  

Energy Technology Data Exchange (ETDEWEB)

Historically the Los Alamos Spallation Radiation Effects Facility (LASREF) has used manual methods to control the position of the 800 kW, 800 MeV proton beam on targets. New experiments, however, require more stringent position control more frequently than can be done manually for long periods of time. Data from an existing harp is used to automatically adjust steering magnets to maintain beam position to required tolerances.

1997-08-01

133

Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997  

Energy Technology Data Exchange (ETDEWEB)

This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the ...

1998-07-01

134

Development of electronic imaging system for real time neutron radiography at TRIGA MK-II research reactor of AERE, Savar, Dhaka and utilization for research and industrial applications  

International Nuclear Information System (INIS)

The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)

2008-09-01

135

Full autonomous monitoring tools inside nuclear reactor building  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and prototypes. Two different ...

2009-07-01

136

Cooperative control for multiple manipulators using an extended passive velocity field control; Passive velocity field control wo mochiita fukuwan kyocho seigyo  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we propose a new cooperative control method for multiple robotic systems that eliminates several issues in the discentralized control method. The proposed control method is constructed by extending a Passive Velocity Field Control (PVFC). It is easy to guarantee the stability in control, because the PVFC can keep the passivity of the controlled system. In this study, the cooperative control method is proposed and then it`s stability is proven. Moreover, it is extended so as to control an internal force and to control a virtual time. Finally, the efficiency of the proposed cooperative control method are examined by computer simulations for cooperation tasks with two manipulators. 11 refs., 7 figs., 1 tab.

1997-12-20

137

Past and future upgrades of the gyrotron high voltage cathode power supplies at the Forschungszentrum Karlsruhe  

Energy Technology Data Exchange (ETDEWEB)

The high voltage/high power DC-cathode power supply for the Gyrotron Test Facility at the Forschungszentrum in Karlsruhe consists of a 12-pulse thyristor star-point-controller, a 130 kV capacitor-bank followed by a tetrode regulator. Originally designed for 80 kV/30 A CW (continous-wave) operation, its operating regime has been extended in line with gyrotron development to pulses of 65 kV/45 A/3 min and more recently to 65 kV/80 A/10 s without any changes to the main load bearing components (thyristors, transformers or power tetrode). This allows testing of gyrotrons in the 0.5 MW (CW), 1 MW (3 min) and 2 MW (10 s) output power range. The paper describes the system, its operation and some critical aspects of the last upgrade, such as the issue of harmonics in the 20 kV distribution mains-grid, the dynamic response of the thyristor-controller and the avoidance of microwave parasitic oscillations in the ...

2009-06-15

138

Remote disassembly of the absorber open-test assembly at the FFTF/IEM cell  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and material experiments. The absorber open-test assembly (AOTA) is a 12-m (40-ft)-long instrumented absorber (control-rod-material) test assembly. Its primary purpose is to characterize the FFTF control-rod-material reaction rate during reactor operation. Instrumentation allowed temperature and pressure measurements at various locations in several absorber pins during reactor operation. After residing several months in the reactor, the assembly was transferred to the IEM cell by the closed-loop ex-vessel machine (CLEM) for separation of the irradiated portion of the experiment from the instrument stalk. After separation, the 3.6-m (12-ft)-long assembly was processed through the sodium removal system and shipped off-site for examination. This success allowed the timely ...

1990-11-11

139

Integrated Safeguards proposal for Finland. Final report on Task FIN C 1264 of the Finnish Support Programme to IAEA Safeguards  

Energy Technology Data Exchange (ETDEWEB)

The IAEA has requested several member states to present their proposal of the application of the Integrated Safeguards (IS) system in their nuclear facilities. This report contains a IS proposal for Finland prepared under the Task FIN C 1264 of The Finnish Support Programme to IAEA Safeguards. The comprehensive safeguards system of the International Atomic Energy Agency (IAEA) has been one of the main tools in the fight against nuclear proliferation since the entry-into-force of the Nuclear Non-proliferation Treaty three decades ago. In the 1990s some of the inherent weaknesses of this so-called traditional safeguards system were revealed first in Iraq and then in North Korea. Therefore, the member states of the LAEA decided to give the Agency additional legal authority in order to make its control system more effective as well as more efficient than before. ...

2000-08-01

140

Selection of melter systems for the DOE/Industrial Center for Waste Vitrification Research  

Energy Technology Data Exchange (ETDEWEB)

The EPA has designated vitrification as the best developed available technology for immobilization of High-Level Nuclear Waste. In a recent federal facilities compliance agreement between the EPA, the State of Washington, and the DOE, the DOE agreed to vitrify all of the Low Level Radioactive Waste resulting from processing of High Level Radioactive Waste stored at the Hanford Site. This is expected to result in the requirement of 100 ton per day Low Level Radioactive Waste melters. Thus, there is increased need for the rapid adaptation of commercial melter equipment to DOE`s needs. DOE has needed a facility where commercial pilot scale equipment could be operated on surrogate (non-radioactive) simulations of typical DOE waste streams. The DOE/Industry Center for Vitrification Research (Center) was established in 1992 at the Clemson University Department of Environmental Systems Engineering, Clemson, SC, to address that ...

1993-12-31

141

Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259  

Energy Technology Data Exchange (ETDEWEB)

The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

1995-05-12

142

Cold regions hydrology and hydraulics  

Energy Technology Data Exchange (ETDEWEB)

This monograph addresses a narrow aspect of cold regions engineering, namely the effects of cold weather on the traditional civil engineering disciplines of hydrology and hydraulics. Hydrologic and hydraulic considerations in the design, construction, and operation of civil works are very important. Many of the problems encountered in the design and construction of buildings, transportation systems, water supply facilities, waste treatment facilities, and hazardous waste disposal facilities, for example are closely tied to the characteristics of the site hydrology.

1990-01-01

143

Security features of a nuclear material accounting system  

Energy Technology Data Exchange (ETDEWEB)

The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various ...

1988-01-01

144

System integration of pattern recognition, adaptive aided, upper limb prostheses  

Science.gov (United States)

The requirements for successful integration of a computer aided control system for multi degree of

1975-01-01

145

Power system stabilizer based on inverse dynamics using an artificial neural network  

Energy Technology Data Exchange (ETDEWEB)

A stable power system stabilizer (PSS) based on the inverse dynamics of the controlled system using an artificial neural network (ANN) is suggested to enhance the dynamic performances of a power system. First, an output feedback control law is driven with some conditions satisfied, which guarantees the internal stability and robustness against the asymptotically stable external disturbances. Then the control law is implemented using the inverse dynamics of the controlled plant. The inverse dynamics of the controlled plant is identified by an ANN, inverse dynamics neural network (IDNN), off-line. The pole-shifting technique and a scaling factor are introduced for the control system to meet the conditions for internal stability and robustness. The proposed ...

1996-06-01

146

Hazard analysis for 300 Area N Reactor Fuel Fabrication and Storage Facilty  

Energy Technology Data Exchange (ETDEWEB)

This hazard analysis (HA) has been prepared for the 300 Area N Reactor Fuel Fabrication and Storage Facility (Facility), in compliance with the requirements of Westinghouse Hanford Company (Westinghouse Hanford) controlled manual WHC-CM-4-46, Nonreactor Facility Safety Analysis Manual, and to the direction of WHC-IP-0690, Safety Analysis and Regulation Desk Instructions, (WHC 1992). An HA identifies potentially hazardous conditions in a facility and the associated potential accident scenarios. Unlike the Facility hazard classification documented in WHC-SD-NR-HC-004, Hazard Classification for 300 Area N Reactor Fuel Fabrication and Storage Facility, (Huang 1993), which is based on unmitigated consequences, credit is taken in an HA for administrative controls or engineered safety features planned or in place. The HA is the ...

1994-01-25

147

Fast Flux Test Facility performance monitoring management information, April 1988  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to provide management with performance data on key performance indicators selected from the FFTF Early Warning System performance indicators.

1988-05-01

148

Los Alamos DP West Plutonium Facility decontamination project  

Energy Technology Data Exchange (ETDEWEB)

The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation.

1982-01-01

152

Implementation and laboratory test results for an adaptive Power System Stabilizer based on linear optimal control  

Energy Technology Data Exchange (ETDEWEB)

Implementation of an adaptive power system stabilizer (PSS) based on linear optimal control is described in this paper. The generator is identified in real time, and a special 3rd order discrete Riccati equation is solved in each sample interval. Because the output of the generator is fed back directly, the controller can track the system very fast. Experimental studies on a physical model of a power system demonstrate the effectiveness of the proposed adaptive optimal controller.

1990-12-01

157

A multi-micro-computer based dual-rate self-tuning power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A dual-rate self-tuning control technique, in which the system identification and control calculation are performed separately, is proposed in this paper. This greatly increases the control rate. A self-tuning power system stabilizer (DSPSS) making use of this technique is developed and implemented using multi-micro-computers. Simulation and experimental results with DSPSS show that the increase in the control rate can considerably improve the system performance.

1987-09-01

159

Managing system for mounted parts and spare parts of power source facilities  

Energy Technology Data Exchange (ETDEWEB)

The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted ...

1995-07-01

160

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole ...

1998-03-01

161

Accelerators for proton and heavy ion radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion ...

1995-03-01

162

Performance of the upgraded LTP-II at the ALS Optical Metrology Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The next generation of synchrotrons and free electron laser facilities requires x-ray optical systems with extremely high performance, generally of diffraction limited quality. Fabrication and use of such optics requires adequate, highly accurate metrology and dedicated instrumentation. Previously, we suggested ways to improve the performance of the Long Trace Profiler (LTP), a slope measuring instrument widely used to characterize x-ray optics at long spatial wavelengths. The main way is use of a CCD detector and corresponding technique for calibration of photo-response non-uniformity [J. L. Kirschman, et al., Proceedings of SPIE 6704, 67040J (2007)]. The present work focuses on the performance and characteristics of the upgraded LTP-II at the ALS Optical Metrology Laboratory. This includes a review of the overall aspects of the design, control system, the movement and measurement regimes for the ...

2008-07-14

163

Low-cost FPSO for service in the Zaafarana oil field  

Energy Technology Data Exchange (ETDEWEB)

The Zaafarana oilfield development, operated by Zaafarana Oil Co. (Zafco) presented a series of unique challenges, including redeployment of an internal-turret mooring system, use of a turret-based electrical-cable jumper system, and permanent use of cable-deployed electric submersible pumps in the gravel-pack well completions. Following a detailed three-dimensional (3D) seismic program, the field was discovered by the first well in December 1990. Four subsequent appraisal wells were drilled. The discovery well and two of the appraisal wells tested oil at rates ranging from 2,000 to 10,100 B/D. Initial development plans called for the use of two conventional platforms with a pipeline to a shore-based treatment and storage terminal. Data acquired from subsequent wells were incorporated into the mapping and reserve estimates resulting in a sharp downgrade of the estimated recoverable reserves. The reduced estimate, combined with a revised pricing ...

1997-04-01

164

Innovative coke oven gas cleaning system for retrofit applications. Volume 1, Public design report  

Energy Technology Data Exchange (ETDEWEB)

This Public Design Report provides, in a single document, available nonproprietary design -information for the ``Innovative Coke Oven Gas Cleaning System for Retrofit Applications`` Demonstration Project at Bethlehem Steel Corporation`s Sparrows Point, Maryland coke oven by-product facilities. This project demonstrates, for the first time in the United States, the feasibility of integrating four commercially available technologies (processes) for cleaning coke oven gas. The four technologies are: Secondary Gas Cooling, Hydrogen Sulfide and Ammonia Removal, Hydrogen Sulfide and Ammonia Recovery, and Ammonia Destruction and Sulfur Recovery. In addition to the design aspects, the history of the project and the role of the US Department of,Energy are briefly discussed. Actual plant capital and projected operating costs are also presented. An overview of the integration (retrofit) of the processes into the existing plant is presented and is followed ...

1994-05-24

165

Environmental Restoration Program quality assurance system requirements for the Hanford Site  

International Nuclear Information System (INIS)

This document defines the quality assurance program requirements for the US Department of Energy, Richland Field Office, Environmental Restoration program at the Hanford Site. This document integrates quality assurance requirements from US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order, and applicable industry standards into a single source document for the development of quality assurance programs applicable to the Environmental Restoration program items and activities. This document has been configured into three parts and fifteen criteria to provide user organizations with a workable document that best facilitates line operations. When developing individual user organization quality assurance programs, the document configuration provides each organization with the Flexibility to incorporate only those parts and criteria that are applicable to their individual scope of work as it is associated with the Environmental ...

166

BEATRIX-II: In situ tritium test  

Energy Technology Data Exchange (ETDEWEB)

The BEATRIX-II irradiation experiment is an in-situ tritium release experiment being carried out in the Fast Flux Test Facility (FFTF) reactor to evaluate the tritium release characteristics of fusion solid breeder materials. A sophisticated tritium gas handling system has been developed to continuously monitor the tritium recovery from the specimens and facilitate tritium removal from the experiment's sweep gas flow stream. The in-situ recovery experiment accommodates two different in-reactor specimen canisters with individual gas streams and temperature monitoring/control. Ionization chambers have been specifically designed to respond to the rapid changes in the tritium release rate at the anticipated tritium concentrations. Two ceramic electrolysis cells have proved effective in reducing the moisture in the gas streams to hydrogen/tritium. A tritium getter system, capable of reducing the ...

1990-01-01

167

Power Systems Development Facility Gasification Test Run TC07  

Energy Technology Data Exchange (ETDEWEB)

This report discusses Test Campaign TC07 of the Kellogg Brown & Root, Inc. (KBR) Transport Reactor train with a Siemens Westinghouse Power Corporation (Siemens Westinghouse) particle filter system at the Power Systems Development Facility (PSDF) located in Wilsonville, Alabama. The Transport Reactor is an advanced circulating fluidized-bed reactor designed to operate as either a combustor or a gasifier using a particulate control device (PCD). The Transport Reactor was operated as a pressurized gasifier during TC07. Prior to TC07, the Transport Reactor was modified to allow operations as an oxygen-blown gasifier. Test Run TC07 was started on December 11, 2001, and the sand circulation tests (TC07A) were completed on December 14, 2001. The coal-feed tests (TC07B-D) were started on January 17, 2002 and completed on April 5, 2002. Due to operational difficulties with the reactor, the unit was taken ...

2002-04-05

168

Development on the cryogenic hydrogen isotopes distillation process technology for tritium removal (Final report)  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is up to about 40% of the total personnel exposure, Ministry of Science and Technology has asked tritium removal facility for requirement of post heavy-water reactor construction. For the purpose of essential removal of tritium from the Wolsung heavy-water reactor system, a preliminary study on the cryogenic Ar-N{sub 2} and H{sub 2}-D{sub 2} distillation process for development of liquid-phase catalytic exchange cryogenic hydrogen distillation process technology. The Ar-N{sub 2} distillation column showed good performance with approximately 97% of final Ar concentration, and a computer simulation code was modified using these data. A simulation code developed for cryogenic hydrogen isotopes (H{sub 2}, HD, D{sub 2}, HT, DT, T{sub 2}) distillation column showed good performance after comparison with the result of a JAERI code, and a H{sub 2}-D{sub 2} distillation column was made. Gas ...

1995-12-01

169

Studies of real-time adaptive optimal excitation controller and adaptive optimal power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

Use of an adaptive optimal control algorithm for two realtime control applications, optimal excitation control of a synchronous generator (OEC) and power system stabilizer (PSS) is described in this paper. Experimental studies on a physical model of a power system show that the proposed OEC and PSS can track the controlled system by parameter identification at different operating conditions. The proposed control algorithm is based on the linear optimal control theory and a special 5th order discrete Riccati equation is solved in each sampling period. The proposed OEC and PSS can always guarantee that in closed loop the controlled system is stable based on the identified parameters. As the actual output of the controlled ...

1992-09-01

170

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

171

THE ANAEROBIC TREATMENT OF WASTES CONTAINING RECALCITRANT AND INHIBITORY COMPOUNDS  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionA collaborative study of the anaerobic treatment of wastes containing recalcitrant and inhibitory compounds using the SERC Anaerobic facility, in particular biomass structure, monitoring and control, catabolism and toxicity, pre-acidification and microbial growth and mesophilic and thermophilic lignocellulose degradation.~%~

1995-01-20

172

Application of robotics in remote fuel fabrication operations  

International Nuclear Information System (INIS)

The Secure Automated Fabrication (SAF) line, an automated and remotely controlled manufacturing process, is scheduled for startup in 1987 and will produce mixed uranium/plutonium oxide fuel pins for the Fast Flux Test Facility (FFTF). The application of robotics in the fuel fabrication and supporting operations is described.

173

40 CFR 63.321 - Definitions.  

Science.gov (United States)

...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...

2009-07-01

174

Coordinated control of multiple manipulator systems  

Energy Technology Data Exchange (ETDEWEB)

A scheme for controlling multimanipulator systems is presented. The control objective is to coordinate the manipulators to perform parts-matching tasks such as screwing a nut onto a bolt. The task of moving a rigid object can be treated as a special case. Two secondary control objectives internal force control and load distribution can be accomplished within the structure of the control law. The internal force control mechanism keeps the internal forces on the object being manipulated at a desirable level. The load distribution mechanism distributes control effort to each manipulator according to a weighting factor. It is also shown that the control algorithm has a modular structure which facilitates its implementation on a multiprocessor computer. The scheme was tested on a planar scara type ...

1993-08-01

175

On the eigenvalue control of electromechanical oscillations by adaptive power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the eigenvalue control strategy which utilizes an adaptive power system stabilizer for the decentralized control of damping and frequency of electromechanical oscillations in power systems. The control procedure includes the complete identification of the decoupled subsystem model in real-time from local measurements only and the assignment of its estimated electromechanical eigenvalue by the change of stabilizer parameters. The robustness and efficiency of the proposed adaptive controller to enhance overall system stability are illustrated in several examples, including the three-machine power system model.

1990-11-01

176

Differential rod worth profile affected by axial blankets in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The central feature of the Fast Flux Test Facility (FFTF) is the fast test reactor (FTR), which is a liquid-sodium-cooled fast reactor providing high fast-neutron flux for irradiation testing of fuels and materials. The FTR also provides a means to develop breeder reactor core components and to gain reactor systems operating experience for future liquid-metal fast breeder reactors (LMFBRs). In the FTR core, there are 82 incore positions (within rows 1 through 6) available for driver fuel assemblies and/or test assemblies. In addition, there are three safety rods and six control rods located in rows 3 and 5, respectively, in the three symmetric core sectors. The FFTF has been successfully and continuously operated for more than 11 reactor cycles. For the first 8 cycles, the core loadings were composed of the mixed-oxide driver fuel assemblies and some test assemblies. These assemblies have an active core section of 91.5 cm ...

1990-06-10

177

Radiation control aspects of the civil construction for a high power free electron laser (FEL) facility  

International Nuclear Information System (INIS)

The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.

1996-11-06

178

Glass Furnace Combustion and Melting Research Facility.  

Energy Technology Data Exchange (ETDEWEB)

The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions ...

2004-08-01

179

The PANDA facility and first test results  

International Nuclear Information System (INIS)

The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport ...

180

Development of linear flow rate control system for eccentric butter-fly valve  

Energy Technology Data Exchange (ETDEWEB)

Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)

1999-12-01

181

Conceptual requirements for large fusion experiment control, data, robotics, and management systems  

International Nuclear Information System (INIS)

The conceptual system requirements for the control, data, robotics, and project management (CDRM) system for the next generation of fusion experiments are developed by drawing on the success of the Tara control and data system. The requirements are described in terms of an integrated but separable matrix of well-defined interfaces among the various systems and subsystems. The study stresses modularity, performance, cost effectiveness, and exportability.

1987-05-11

182

Risk evaluation system for facility safeguards and security planning  

International Nuclear Information System (INIS)

The Risk Evaluation System (RES) is an integrated approach to determining safeguards and security effectiveness and risk. RES combines the planning and technical analysis into a format that promotes an orderly development of protection strategies, planning assumptions, facility targets, vulnerability and risk determination, enhancement planning, and implementation. In addition, the RES computer database program enhances the capability of the analyst to perform a risk evaluation of the facility. The computer database is menu driven using data input screens and contains an algorithm for determining the probability of adversary defeat and risk. Also, base case and adjusted risk data records can be maintained and accessed easily.

1987-07-12

183

Low-level and transuranic waste transportation, disposal, and facility decommissioning cost sensitivity analysis  

Energy Technology Data Exchange (ETDEWEB)

The Systems Design Study (SDS) identified technologies available for the remediation of low-level and transuranic waste stored at the Radioactive Waste Management Complex's Subsurface Disposal Area at the Idaho National Engineering Laboratory. The SDS study intentionally omitted the costs of transportation and disposal of the processed waste and the cost of decommissioning the processing facility. This report provides a follow-on analysis of the SDS to explore the basis for life-cycle cost segments of transportation, disposal, and facility decommissioning; to determine the sensitivity of the cost segments; and to quantify the life-cycle costs of the 10 ex situ concepts of the Systems Design Study.

1992-05-01

184

Low-level and transuranic waste transportation, disposal, and facility decommissioning cost sensitivity analysis  

Energy Technology Data Exchange (ETDEWEB)

The Systems Design Study (SDS) identified technologies available for the remediation of low-level and transuranic waste stored at the Radioactive Waste Management Complex`s Subsurface Disposal Area at the Idaho National Engineering Laboratory. The SDS study intentionally omitted the costs of transportation and disposal of the processed waste and the cost of decommissioning the processing facility. This report provides a follow-on analysis of the SDS to explore the basis for life-cycle cost segments of transportation, disposal, and facility decommissioning; to determine the sensitivity of the cost segments; and to quantify the life-cycle costs of the 10 ex situ concepts of the Systems Design Study.

1992-05-01

185

Predictive wavefront control for Adaptive Optics with arbitrary control loop delays  

Energy Technology Data Exchange (ETDEWEB)

We present a modification of the closed-loop state space model for AO control which allows delays that are a non-integer multiple of the system frame rate. We derive the new forms of the Predictive Fourier Control Kalman filters for arbitrary delays and show that they are linear combinations of the whole-frame delay terms. This structure of the controller is independent of the delay. System stability margins and residual error variance both transition gracefully between integer-frame delays.

2007-10-30

186

Overall control and monitoring systems for pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

Experience and technical innovations in power plant engineering have resulted in continuous improvements of operation control, availability and safety of pumped storage plants. Process control is constantly improved as new developments are made in equipment and systems engineering. Plant control concepts with increasingly complex automation hierarchy are described by which pumped storage processes can be controlled optimally, reliably, and automatically.

1982-01-01

187

Dynamics and controls working group summary  

Energy Technology Data Exchange (ETDEWEB)

The technology status of the dynamics and controls discipline as it applies to energy storage wheel systems was evaluated. No problems were identified for which an adequate solution could not be proposed. Design issues that influence control were addressed. The dynamics and control aspects associated with the energy storage system concept and its various constituent parts, and the control tasks attendant to large, manned spacecraft are discussed.

1984-11-01

188

On load flow control in electric power systems  

Energy Technology Data Exchange (ETDEWEB)

This dissertation deals with the control of active power flow, or load flow in electric power systems. During the last few years, interest in the possibilities to control the active power flows in transmission systems has increased significantly. There is a number of reasons for this, coming both from the application side - that is, from power system operations - and from the technological side. where advances in power electronics and related technologies have made new system components available. Load flow control is by nature a multi-input multi-output problem, since any change of load flow in one line will be complemented by changes in other lines. Strong cross-coupling between controllable components is to be expected, and the possibility of adverse interactions between these components cannot be rejected ...

2000-01-01

189

Method and system for controlling the idle speed of an internal combustion engine at variable ignition timing  

Energy Technology Data Exchange (ETDEWEB)

The idle speed of an internal combustion engine is controlled in response to a variable ignition timing control signal from a microcomputer. The microcomputer derives this control signal as a function of the magnitude of engine speed variation which occurs during engine idle periods to cause the ignition timing to vary quickly in response to a transitory engine load variation. An auxiliary air delivery system may be advantageously incorporated in the idle speed control system to cooperate with the ignition timing control in response to the engine speed variation.

1984-05-08

190

Hybrid ventilation. Control strategies for hybrid ventilation, consequences for air quality, thermal comfort and energy use; Hybrid ventilasjon  

Energy Technology Data Exchange (ETDEWEB)

This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.

2001-07-01

191

Dynamic performance testing of control valves  

International Nuclear Information System (INIS)

Response of control valves plays an important role in the dynamics of the flow system as a whole. Knowledge of its transfer function would facilitate analysis of the behaviour of the system. This paper presents the application of Levy's complex curve fitting method for determination of the transfer function of control valves used in Liquid Zone Control System of 540 MWe PHWR. (author)

2005-02-01

192

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without calibration adjustment to reveal the error involved. The calibration ...

2008-11-19

193

A distributed control framework for smart grid development: Energy/water system optimal operation and electric grid integration  

British Library Electronic Table of Contents (United Kingdom)

In this work, we propose a conceptual distributed control framework for electrical grid integrated with distributed renewable energy generation systems in order to enable the development of the so-called ''smart electrical grid''. First, we introduce the key elements and their interactions in the proposed control architecture and discuss the design of the distributed control systems which are able to coordinate their actions to account for optimization considerations on the system operation. Subsequently, we focus on a specific wind/solar energy generation system connected to a reverse osmosis water desalination system and the electrical grid and design two supervisory predictive controllers via model predictive control to operate the integrated system taking ...

2011-01-01

194

Waste monitoring system for effluents  

Energy Technology Data Exchange (ETDEWEB)

The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.

1995-07-01

195

Radionuclide buildup in FFTF [Fast Flux Test Facility] heat transport system cells  

International Nuclear Information System (INIS)

The purpose of the work reported in this paper was to measure the radionuclide buildup in primary heat transport system cell No. 3 at the Fast Flux Test Facility (FFTF) and to compare the results with predicted values from a model based on experimental studies and experience at similar reactors. The information obtained is used for maintenance planning and to enhance ability to assess radionuclide buildup in the future at FFTF and in other reactors.

1989-11-26

196

An adaptive self-optimizing power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A self-optimizing pole-shifting control algorithm has been developed for an adaptive power system stabilizer (APSS) to improve its dynamic performance and autonomous operation. The proposed algorithm deals with the system frequency and time domain characteristics simultaneously to guarantee stability and to enhance the performance of the closed-loop system. The mechanism of discrete control system control limits influencing the closed loop system behaviour is studied. Short-term behaviour is studied by introducing the concept of a short-term behaviour index. With the introduction of dynamic control limits, an effective discrete control system design method is proposed. A PSS oriented power system dynamics simulation package (PSDSP) has ...

1994-01-01

197

Implementation and Evaluation ... - Intelligent Systems Division - NASA  

Science.gov (United States)

[9] Rysdyk, R. T., and Calise, A. J., Fault Tolerant Flight control via Adaptive Neural Augmentation, AIAA. Guidance, Navigation, and Control Conference, Aug. ...

198

Design of the electromagnetic actuator for vibration control of a flexible rotor  

Energy Technology Data Exchange (ETDEWEB)

In order to suppress resonance vibrations of a rotor-shaft of rotating machinery, a rotor-shaft system elastically supported by ball bearings which are installed in electromagnetic actuators are proposed and the design method of some compensatory circuits in the controller to control the electromagnetic actuators in the system are explained. These actuators are controlled by the analog PID (proportional, integral, and derivative) controller. The compensation for nonlinearity of electromagnetic force, the negative stiffness of electromagnet, and the time lag of the coil current are discussed and the effective control circuits are proposed. The rotor-shaft system is replaced by the equivalent two-degree-of-freedom system and both impulse and frequency responses are numerically simulated for several ...

1994-12-21

199

AIR ... - Human Factors Research and Technology Division - NASA  

Science.gov (United States)

TRACON controller, traffic flow manager, or pilot. .... separation violations to individual controller and ..... System, AGARD Meeting on Machine Intelligence ...

200

A neuro power system stabilizer based on adaptive control technique  

Energy Technology Data Exchange (ETDEWEB)

A power system stabilizer based on GMV (Generalized Minimum Variance), one of the adaptive control techniques, is developed to enhance the dynamic performances of a power system using an Artificial Neural Network (ANN). The stabilizer consists of two parts. One part is Inverse Dynamics Neural Networks (IDNN), which is trained to identify the inverse dynamics of controlled plant and used as a one-step ahead controller, or inverse controller. The other part is Adaptive Reference Model (ARM), which prevents excessive controller output. The ARM produces the modified reference value by minimizing a cost function recursively on the assumption that the IDNN perfectly identifies the controlled plant. The IDNN is used in the minimization procedure to calculate the sensitivities. The proposed controller is ...

1996-12-31

201

Annual report on heavy water reactor fuel fabrication  

Energy Technology Data Exchange (ETDEWEB)

The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing ...

1994-03-01

202

Waste sampling and characterization facility (WSCF) maintenance implementation plan  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP) is written to satisfy the requirements of the US Department of Energy (DOE) Order 4330.4B, Maintenance Management Program that specifies the general policy and objectives for the establishment of the DOE controlled maintenance programs. These programs provide for the management and performance of cost effective maintenance and repair of the DOE property, which includes facilities. This document outlines maintenance activities associated with the facilities operated by Waste Management Hanford, Inc. (WMH). The objective of this MIP is to provide baseline information for the control and execution of WMH Facility Maintenance activities relative to the requirements of Order 4330.4B, assessment of the WMH maintenance programs, and actions necessary to maintain compliance with the Order. Section 2.0 summarizes the history, mission and description ...

1997-08-13

203

Study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit.  

Science.gov (United States)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsun...

1996-01-01

204

Direct liquefaction Proof-of-Concept facility. Final technical progress report  

Energy Technology Data Exchange (ETDEWEB)

This report presents the results of work which included extensive modifications to HRI`s existing 3 ton per day Process Development Unit (PDU) and completion of the first PDU run. The 58-day Run 1 demonstrated scale-up of the Catalytic Two-Stage Liquefaction (CTSL Process) on Illinois No. 6 coal to produce distillate liquid products at a rate of up to 5 barrels per to of moisture-ash-free coal. The Kerr McGee Rose-SR unit from Wilsonville was redesigned and installed next to the US Filter installation to allow a comparison of the two solids removal systems. Also included was a new enclosed reactor tower, upgraded computer controls and a data acquisition system, an alternate power supply, a newly refurbished reactor, an in-line hydrotreater, interstage sampling system, coal handling unit, a new ebullating pump, load cells and improved controls and remodeled preheaters. Distillate ...

1995-08-01

205

Variable structure system based logic fuzzy control of bridge vibration using fail-safe magnetorheological fluid dampers  

Science.gov (United States)

This paper presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing deices and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitations. The sufficient condition for the closed-loop stability of the fuzzy control system is derived from the variable structure system theory. It is demonstrated that this stable fuzzy control system can significantly reduce the relative deck displacement using about 55 percent less power compared to passive-on state, while the absolute deck acceleration is relatively unaffected.

2002-06-01

206

State-of-the-Art developments in accelerator controls at the APS.  

Energy Technology Data Exchange (ETDEWEB)

The performance requirements of the Advanced Photon Source (APS) challenge the control system in a number of areas. This paper will review a few applications of advanced technology in the control and monitoring of the APS. The application of digital signal processors (DSPs) and techniques will be discussed, both from the perspective of a large distributed multiprocessor system and from that of embedded systems. In particular, two embedded applications will be highlighted, a beam position monitor processor and a DSP-based power supply controller. Fast data distribution is often a requirement. The application of a high-speed network based on reflective memory will also be discussed in the context of the APS global orbit feedback system. Timing systems provide opportunities to apply technologies such as high-speed logic and ...

1999-04-13

207

Potential benefits of using commercial simulators to test equipment control systems  

Energy Technology Data Exchange (ETDEWEB)

Motivation is given for a technique to more thoroughly test semiconductor equipment control systems. A description is given of a simulator-based control system testing technique. Potential benefits that could be realized by using this technique in the semiconductor industry as well as benefits documented by using this technique in other industries are described. Specific requirements for using the technique in the semiconductor industry are outlined. A summary of a survey of nine commercial simulation systems is given. Finally, the outcome of the survey is compared with the requirements for using the technique.

1997-09-01

208

Physics through the 1990s: scientific interfaces and technological applications  

Energy Technology Data Exchange (ETDEWEB)

The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics--biophysics, the brain, and theoretical biology; the physics-chemistry interface--instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics--tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics--complex systems and applications in basic research; mathematics--field theory and chaos; microelectronics--integrated circuits, miniaturization, future trends; optical information technologies--fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security--devices, weapons, and arms control; medical physics--radiology, ultrasonics, NMR, and photonics. An executive summary and many chapters contain recommendations ...

1986-01-01

209

Monitoring power plant fireside corrosion using corrosion probes  

Energy Technology Data Exchange (ETDEWEB)

The ability to monitor the corrosion degradation of key components in fossil fuel power plants is of utmost importance for Futuregen and ultra-supercritical power plants. Fireside corrosion occurs in the high temperature sections of energy production facilities due to a number of factors: ash deposition, coal composition, thermal gradients, and low NOx conditions, among others. Problems occur when equipment designed for either oxidizing or reducing conditions is exposed to alternating oxidizing and reducing conditions. This can happen especially near the burners. The use of low NOx burners is becoming more commonplace and can produce reducing environments that accelerate corrosion. One method of addressing corrosion of these surfaces is the use of corrosion probes to monitor when process changes cause corrosive conditions. In such a case, corrosion rate could become a process control variable that directs the operation of a coal combustion or ...

2005-01-01

210

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 input decks ...

1993-01-01

211

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 input decks for ...

1993-05-01

212

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

International Nuclear Information System (INIS)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 input decks for ...

1993-07-06

213

Fast Implementation of Matched Filter Based Automatic Alignment Image Processing  

Energy Technology Data Exchange (ETDEWEB)

Video images of laser beams imprinted with distinguishable features are used for alignment of 192 laser beams at the National Ignition Facility (NIF). Algorithms designed to determine the position of these beams enable the control system to perform the task of alignment. Centroiding is a common approach used for determining the position of beams. However, real world beam images suffer from intensity fluctuation or other distortions which make such an approach susceptible to higher position measurement variability. Matched filtering used for identifying the beam position results in greater stability of position measurement compared to that obtained using the centroiding technique. However, this gain is achieved at the expense of extra processing time required for each beam image. In this work we explore the possibility of using a field programmable logic array (FPGA) to speed up these computations. The results indicate a ...

2008-04-02

214

Environmental Restoration Remedial Action quality assurance requirements document  

International Nuclear Information System (INIS)

This document defines the quality assurance requirements for the US Department of Energy-Richland Operations Office Environmental Restoration Remedial Action program at the Hanford Site. The Environmental Restoration Remedial Action program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency. This document combines quality assurance requirements from various source documents into one set of requirements for use by the US Department of Energy-Richland Operations Office and other Environmental Restoration Remedial Action program participants. This document will serve as the basis for developing Quality Assurance Program Plans and implementing procedures by the participants. The requirements of this document will be applied to activities affecting quality, using a graded approach based on ...

215

Development of Improved Burnable Poisons for Commercial Nuclear Power Reactors  

Energy Technology Data Exchange (ETDEWEB)

Burnable poisons are used in nuclear reactors to produce a more level distribution of power in the reactor core and to reduce to necessity for a large control system. An ideal burnable poison would burn at the same rate as the fuel. In this study, separation of neutron-absorbing isotopes was investigated in order to eliminate isotopes that remain as absorbers at the end of fuel life, thus reducing useful fuel life. The isotopes Gd-157, Dy-164, and Er-167 were found to have desirable properties. These isotopes were separated from naturally occurring elements by means of plasma separation to evaluate feasibility and cost. It was found that pure Gd-157 could save approximately $6 million at the end of four years. However, the cost of separation, using the existing facility, made separation cost- ineffective. Using a magnet with three times the field strength is expected to reduce the cost by a factor of ten, making ...

2003-09-30

216

Design of the ZTH vacuum liner  

Energy Technology Data Exchange (ETDEWEB)

The current status of the ZTH vacuum liner design is covered by this report. ZTH will be the first experiment to be installed in the CPRF (Confinement Physics Research Facility) at the Los Alamos National Laboratory and is scheduled to be operational at the rated current of 4 MA in 1992. The vacuum vessel has a 2.4 m major radius and a 40 cm minor radius. Operating parameters which drive the vacuum vessel mechanical design include a 300 C bakeout temperature, an armour support system capable of withstanding 25 kV, a high toroidal resistance, 1250 kPa magnetic loading, a 10 minute cycle time, and high positional accuracy with respect to the conducting shell. The vacuum vessel design features which satisfy the operating parameters are defined. The liner is constructed of Inconel 625 and has a geometry which alternates sections of thin walled bellows with rigid ribs. These composite sections span between pairs of the 16 diagnostic stations to ...

1987-01-01

217

ARIES-AT safety design and analysis  

Energy Technology Data Exchange (ETDEWEB)

ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather ...

2006-01-15

218

ARIES-AT safety design and analysis  

International Nuclear Information System (INIS)

ARIES-AT is a 1000 MWe conceptual fusion power plant design with a very low projected cost of electricity. The design contains many innovative features to improve both the physics and engineering performance of the system. From the safety and environmental perspective, there is greater depth to the overall analysis than in past ARIES studies. For ARIES-AT, the overall spectrum of off-normal events to be examined has been broadened. They include conventional loss of coolant and loss of flow events, an ex-vessel loss of coolant, and in-vessel off-normal events that mobilize in-vessel inventories (e.g., tritium and tokamak dust) and bypass primary confinement such as a loss of vacuum and an in-vessel loss of coolant with bypass. This broader examination of accidents improves the robustness of the design from the safety perspective and gives additional confidence that the facility can meet the no-evacuation requirement under average weather ...

2006-01-01

219

Pollution control instrumentation for oil and effluents  

Energy Technology Data Exchange (ETDEWEB)

This book provides discusses recent developments in oil pollution control instrumentation. Some of the topics covered are as follows: 1. Technical requirements of the IMCO International Performance and Test Specification A393x concerning oil content meters; and 2. Oil in water detection; and 3. Methods for the disposal of recovered oil and oily sludge; and 4. Oil content monitoring at ballast water treatment facilities and offshore production platforms.

1986-01-01

220

Development of a system model for the postclosure assessment of a concept for geological disposal of Canada`s nuclear fuel waste  

Energy Technology Data Exchange (ETDEWEB)

Atomic Energy of Canada has recently submitted for regulatory and public review an Environmental Impact Statement (EIS) on a concept for disposal of Canada`s nuclear fuel waste. The EIS is supported by nine primary references that summarize major aspects of the concept, including a postclosure environmental and safety assessment. The scope of the postclosure assessment is largely determined by the requirements of the Atomic Energy Control Board (AECB) of Canada. These requirements include a quantitative estimate of the annual effective dose equivalent to an individual in the most exposed group of people (the critical group) for 10,000 years following closure of the disposal facility, and a radiological risk criterion with an associated dose rate limit of 0.05 mSv/a. Over this long time frame, a quantitative assessment cannot be based on actual observations, and thus we use scientific arguments and simulations with mathematical models to infer ...

1995-12-01

221

The first PANDA tests  

International Nuclear Information System (INIS)

The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be favorably responsive and ...

222

Remote control monitoring - a review of the latest equipment  

Energy Technology Data Exchange (ETDEWEB)

This article reviews briefly a range of the latest monitoring and controlling equipment for use in coal mines. This includes pressure transmitters, shale/coal discriminator, nucleonic bunker level indicator, automatic steering and monitoring system, oscilloscope/multimeter, and microprocessor based digital display controllers. 1 fig.

1988-01-01

223

Overall control and monitoring systems for pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

The article describes control and monitoring concepts in which the delegation of responsibility is becoming more decisive than ever (automation hierarchy), and which are capable of optimized, automatic control of process events in pumped storage plants. 8 refs.

1982-06-01

224

Modular control of human walking: Adaptations to altered mechanical demands  

UK PubMed Central (United Kingdom)

Studies have shown that the nervous system may adopt a control scheme in which synergistic muscle groups are controlled by common excitation patters, or modules, to simplify the coordination...Full Text Available

2010-02-10

225

Problems and solutions of the IFSMTF power and switch system  

Energy Technology Data Exchange (ETDEWEB)

Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.

1985-01-01

226

Real time control of micro-machine system using micro-computer based fuzzy logic power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.

1994-12-01

227

Managing diverse stakeholders in enterprise systems projects: a control portfolio approach  

British Library Electronic Table of Contents (United Kingdom)

While substantial research has examined the control of information systems (IS) projects, most studies in this area have only examined how one controller manages a single group of controllees. However, many IS projects, especially enterprise systems projects (often initiated by an organization's corporate headquarters, and involving business unit users and consultants), have multiple stakeholders. The corporate headquarters (the project's principal controller) must simultaneously ensure that the various stakeholders are aligned with the project's goals despite their diverse motivations, and that the stakeholders collaborate with each other to achieve project success. Behavior control theory argues that the controller enacts a control portfolio of formal and informal controls. However, the ...

2011-01-01

228

Design of the decision aiding system for the control of the research nuclear reactor; Conception d'un systeme d'aide a la decision pour le controle d'un reacteur nucleaire de recherche  

Energy Technology Data Exchange (ETDEWEB)

Intelligent and decision aiding systems as support to operators are becoming increasingly a necessity in nuclear installations and in nuclear reactors in particular, specially after the Tree Mile Island. Development of new technologies based on linguistic approaches such as fuzzy logic has given rise to much interest during the last years. Fuzzy logic controller (FLC) has many advantage compared to conventional controllers using classical techniques. The aim of the present work is to use a fuzzy logic controller in parallel to actual semi-automatic controller in order to supervise in real time the operation of the research nuclear reactor. The principal of this controller is based on rules which are established previous from experiment using the semi-automatic controller and from the knowledge of the operators. (authors)

2003-07-01

229

New neutron simulation capabilities provided by the Sandia Pulse Reactor (SPR-III) and the Upgraded Annular Core Pulse Reactor (ACPR)  

Science.gov (United States)

The paper briefly describes the nuclear reactor facilities at Sandia Laboratories which are used for simulating nuclear weapon produced neutron environments. These reactor facilities are used principally in support of continuing R and D programs for the Department of Energy/Office of Military Application (DOE/OMA) in studying the effects of radiation on nuclear weapon systems and components. As such, the reactors are available to DOE and DOD agencies and their contractors responsible for the radiation hardening of advanced nuclear weapon systems. Emphasis is placed upon two new reactor simulation sources; the Sandia Pulse Reactor-III (SPR-III) Facility which enhances the neutron exposure volume capabilities over those presently available with the existing SPR-II Facility, and the Upgraded Annular Core Pulse Reactor (ACPR) Facility which ...

1978-07-01

230

Method and apparatus for operation of a dual fuel compression ignition combustion engine  

Energy Technology Data Exchange (ETDEWEB)

A dual fuel engine control system for controlling the power output of a dual fuel compression ignition engine. The engine includes mixing means for combining an oxidizer and a primary fuel at a substantially constant ratio of oxidizer to primary fuel. The power output of the engine is controlled through the use of a throttle valve controlling the quantity of combustible mixture delivered to the combustion chamber. The fuel control system minimizes the quantity of ignition fuel required by controlling the quantity of combustible mixture rather than the fuel of air ratio. (author) figs.

1994-03-03

231

Linearization of Valve Flow Characteristics for Steam Turbine Control  

Energy Technology Data Exchange (ETDEWEB)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)

2009-10-15

232

Linearization of Valve Flow Characteristics for Steam Turbine Control  

International Nuclear Information System (INIS)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC)

2009-10-01

233

Verification of the CFD code FLUENT by post test calculation of ROCOM experiments  

International Nuclear Information System (INIS)

Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV ...

2005-10-02

234

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems  

Energy Technology Data Exchange (ETDEWEB)

Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane ...

2010-07-08

235

Experimental study on fuzzy logic vibration control of a bridge using fail-safe magnetorheological fluid dampers  

Science.gov (United States)

This study presents a semi-active vibration control of a scaled two-span bridge structure. Magneto-rheological fluid dampers are utilized as the semi-active energy absorbing devices, and a bridge vibration control system is developed. Closed-loop control system based on fuzzy logic is used to suppress the bridge deck motion under random excitation. It is demonstrated that this fuzzy logic control system can significantly reduce the relative deck displacement using about 60% less power compared to passive on state, while the absolute deck acceleration remains practically unchanged.

2001-07-01

236

A Grafcet-based expert system for process control; Un systeme expert base sur le Grafcet pour le controle de procede  

Energy Technology Data Exchange (ETDEWEB)

This article describes a hierarchical and functional model for continuous process control aid. The expertise is represented by graphs from a simple functional restructuring of the Grafcet, which is the formalism used by the designers of the command-control program. The new structure is familiar to the operator, and it is settled in an expert system. The application built on the basis of this method detects some default types which are not detected by the control-command. It proposes a diagnosis to the operator, and can explain and justify the state of the process. (authors) 9 refs.

1997-11-01

237

Maintenance implementation plan for T Plant. Revision 2  

Energy Technology Data Exchange (ETDEWEB)

This document is a Maintenance Implementation Plan (MIP) for the T Plant Facility complex located in the 200 West Area of the Hanford Reservation in Washington state. This plan has been developed to provide a disciplined approach to maintenance functions and to describe how the T Plant facility will implement and comply with the regulations according to US DOE order 4330.4B, entitled Maintenance Management Program, Chapter 2.0 {open_quotes}Nuclear Facilities{close_quotes}. Physical structures, systems, processes, as well as all associated equipment specifically assigned to these groups are included in the MIP.

1995-05-01

238

Enterprise energy management : Part 1  

Energy Technology Data Exchange (ETDEWEB)

The needs of large industrial, commercial, and institutional energy consumers are more closely connected with the needs of power utilities and energy services companies, a result of the evolving global energy environment. Consumer choice, competition amongst energy suppliers, and increased demand are brought about in some regions by deregulation. Increasingly, large energy consumers expect high levels of quality and reliability from the energy delivered. As a result, management of the cost and the quality of the energy product and the energy assets that produce, deliver, control and consume it requires different strategies. Three major challenges must be overcome: (1) requirement to support economic and efficient delivery, purchasing and use of energy, (2) requirement to guarantee higher levels of power quality and reliability, and (3) requirement to supply the growing demand for energy while establishing a market-based pricing system. The ...

2001-09-01

239

Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins  

International Nuclear Information System (INIS)

A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.

240

Facilities Condition and Hazards Assessment for Materials and Fuel Complex Facilities MFC-799, 799A, and 770C  

Energy Technology Data Exchange (ETDEWEB)

The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these ...

2009-11-01

241

Evolution of reactivity control mechanisms for nuclear research and power reactors in India  

International Nuclear Information System (INIS)

Division of Remote Handling and Robotics (DRHR) at Bhabha Atomic Research Centre (BARC) has been working on design and development of Reactivity Control Mechanisms for Nuclear Research Reactors (Dhruva, KAMINI and recently Critical Facility of Advanced Heavy Water Reactor (AHWR)) as well as Power Reactors in India (Pressurized Heavy Water Reactors of 220 MWe at Narora and recently India's first 540 MWe PHWR Unit -1 and 2 at Tarapur). This paper gives a brief account of evolution of reactivity control mechanisms for nuclear research and power reactors in India. (author)

2009-10-01

242

Computer control of fuel handling activities at FFTF  

International Nuclear Information System (INIS)

The Fast Flux Test Facility near Richland, Washington, utilizes computer control for reactor refueling and other related core component handling and processing tasks. The computer controlled tasks described in this paper include core component transfers within the reactor vessel, core component transfers into and out of the reactor vessel, remote duct measurements of irradiated core components, remote duct cutting, and finally, transferring irradiated components out of the reactor containment building for off-site shipments or to long term storage. 3 refs., 16 figs.

1985-09-08

243

Sodium technology technical progress report, April, May, June 1975  

Science.gov (United States)

Progress is reported in the following areas: radioactivity control technology, FFTF sodium characterization system, corrosion and process control, and fuel failure monitoring systems for FFTF and CRBRP. (JWR)

1975-12-01

245

Improvement of power system stability by high speed power control of adjustable speed machine; Kahensokuki no koshutsuryoku seigyo ni yoru denryoku keito no anteido kojo  

Energy Technology Data Exchange (ETDEWEB)

Large capacity adjustable speed machines (ASMs) at pumped storage power station have been put into full operation and the operating characteristics of ASM have been highly evaluated from the view point of power system operation. The output power (input power) of ASM can be controlled very quickly by applying a vector control scheme to the excitation control. This quick responsive feature of ASM can make it possible to improve the stability of the neighbor sub-power system. For improvement of transient stability, the output power of ASM is reduced very quickly in order to control the acceleration of neighbor generators during and after transmission line faults. For improvement of dynamic stability, the output power of ASM is modulated in accordance with the stabilizing signals detected from the swing of generator rotor or the power flow fluctuation on the ...

1997-01-20

246

Studies of neural networks for engine control: application to the electromechanical valves engine; Etudes des reseaux de neurones pour le controle moteur: application a soupapes electromecaniques  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)

1997-12-31

247

The development of automatic surface dose-rate measuring and recording system for radioactive waste drum  

International Nuclear Information System (INIS)

The system which is performed the transportation and measurement of drum automatically to measure the surface dose-rate of radioactive waste drum and can inspect place of contaminated sources and precise dose-rate within a drum according to measuring many places equally at the same time has been developed. It is expected that the system be used to minimized radiation exposure of workers and manage the drum effectively according to established at the production facilities as well as the radioactive waste treatment facilities. (author). 7 refs., 9 tabs., 16 figs.

248

Southern receiver system: Environmental impact assessment status report: Conawapa to Winnipeg Power Transmission Complex  

Energy Technology Data Exchange (ETDEWEB)

The Conawapa-Winnipeg Power Transmission Complex includes five interrelated transmission and conversion facilities. This booklet describes work done on the upgrade of the southern receiver system, one component of the complex. The southern receiver system is composed of a network of high voltage transmission lines and station facilities. The booklet includes a description of the upgrade, the project setting, short and long-term effects and impact management, and the next steps to be taken in the process, including the regulatory process and public consultation.

1992-01-01

249

Information on Hanford site cribs and septic systems  

Energy Technology Data Exchange (ETDEWEB)

This document provides information on septic systems with a design capacity of greater than 14,500 gal/d and cribs submitted as requested by the Washington State Department of Ecology. Data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. Information concerning the deactivation method for a facility is included when such information is available.

1988-05-01

250

A review of the gas species activity and control of pulsed plasma technology during the nitriding, carburizing and carbonitriding processes  

Energy Technology Data Exchange (ETDEWEB)

The control of gas activity and process technology has developed tremendously over the past two decades. While once considered to be primitive control systems using simple PID loops with thermocouples that were suspect and unable to perform repeatedly and consistently during the arduous process of plasma nitriding and processing, developments in recent years have elevated the control of the process into what might be considered one of the most controllable processes of the latter part of this century. The advent of plasma processing technology has improved control methods by observing and harnessing each of the various process parameters into many different combinations of control systems. Some of these control systems can control the complete function of the ...

1995-12-31

251

Internal dose from tritium at Wolsung nuclear power plant  

International Nuclear Information System (INIS)

Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction "2H(n,#gamma#)"3H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D_2O and 35 Ci/kg-D_2O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium contribution to the total plant man-Sv changes between 30 ...

1995-02-01

252

Initiation of conformal radiotherapy with a multileaf-collimator - An approach to clinical routine  

International Nuclear Information System (INIS)

The implementation of a three-dimensional conformal radiotherapy facility in the radiotherapy department of the Heinrich Heine University is described. Complex radiotherapy techniques with commercially available networked systems are introduced to improve clinical work. Over 18 month we have gained clinical experience with a PHILIPS Multileaf Collimator (MLC) mounted on a SL 25 linear accelerator. For a limited period the MLC was used as a conventional blocking device. The standard MLC-shapes are controlled with a stand-alone computer system. In addition, a three-dimensional treatment planning system (3-D-TPS / TMS-Radix, Helax AB) based on convolution/superposition algorithms was recently installed. Treatment optimization is achieved using static field arrangements with complete volumetric computerized tomographic patient data for 3-D-TPS. Conformal adaptation of the 95%-isodose to ...

1995-10-01

253

Constitution of a centralised data base for the internal quality control in radiotherapy; Constitution d'une base de donnees centralisee pour le controle de qualite interne en radiotherapie  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project was to implement a centralised data base of internal quality control in radiotherapy according to the criteria of the decree of A.f.s.s.a.p.s. (French agency of sanitary safety of health products on 27 july 2007, about the internal quality control of external radiotherapy facilities. The software on one year meets the objectives: compliance by comparison with A.f.s.s.a.p.s. criteria but particularly optimization of the centralisation and analysis of the internal quality controls. (N.C.)

2009-10-15

254

Report: Mathematics and Science  

Science.gov (United States)

... and Security..........................13 Materials Science ... hybrid system theory, Internet analysis, materials science, mixing, physiology, iterative control ...

256

Adaptive Nonlinear Autopilot for Anti-Air Missiles.  

Science.gov (United States)

... A control design methodology enabling the adaptive neural augmentation. ... As an example, the problem of designing a neural augmentation system. ...

2011-05-12

257

Active Shimmy Control System  

Science.gov (United States)

... Both effects are undoubtedly caused by the ahaping of the spool valve flow characteristics The linear region of response corresponds to ...

1975-12-01

258

Process energy management  

Energy Technology Data Exchange (ETDEWEB)

In many facilities, energy management is simply a matter of managing the energy required for lighting and space conditioning. In many others, however, energy management is much more complex and involves large motors and controls, industrial insulation, complex combustion monitoring, unique steam distribution problems, significant amounts of waste heat, etc. Typical facilities offering large energy management opportunities include industrial facilities, large office and commercial operations, government institutions such as schools, hospitals and prisons. Such facilities generally have specialized industrial, commercial or institutional processes that incorporate many of the concepts covered in other chapters. These processes require thorough analytical evaluations to determine the appropriate energy-saving measures. This chapter provides some examples. In this chapter the authors ...

1994-12-31

259

Real-time coordination of secondary voltage control and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper is devoted to the coordination of secondary voltage control and adaptive parameters resetting of the power system stabilizer, in order to increase stability, margins in real time operation. Secondary voltage control and the power system stabilizer are two control loops, which affect the same system parameter on different bases - that parameter is the voltage set-point of the automatic voltage regulator. It was found that their effects were complementary. In that way, through the proper coordination of actions of these two control loops open up a wide range of possibilities for ensuring the stability of bulk power systems in real time. For the establishment of this coordination, an on-line sequential algorithm is proposed which is based on adaptive resetting of the voltage set-point of the automatic voltage ...

2002-06-01

260

Unmanned Systems Update. SPAWAR Systems Center ...  

Science.gov (United States)

... Multi-robot Operator Control ... Way-point navigation (UUV performing lawn-mower ... Funded by JIEDDO to improve operation of EOD robots ...

2011-03-16

261

Guidance and Control System for an Autonomous Vehicle  

Science.gov (United States)

... operational AUV and Unmanned Underwater Vehicle (UUV) ... by Brooks with land-based robots [BROOKS 88 ... system for a mobile land robot called ...

1990-06-01

262

Fuel assemblies inspection system - (SICOM)  

Energy Technology Data Exchange (ETDEWEB)

An inspection system was developed for spent fuel assemblies of PWR so that to check their general state, perform dimensional control and measure oxide layer thickness of peripheral rods. (orig./HP)

1995-12-31

263

Electronics in mining symposium  

Energy Technology Data Exchange (ETDEWEB)

The symposium reviewed the use of electronics in mining today. Subjects covered include control systems; remote sensing; telemetry; data transmission; microprocessors and transportation systems. 15 papers have been abstracted separately.

1984-01-01

264

Diesel engine systems for underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

This standard specifies requirements for the flameproofing and the limiting of surface temperature and exhaust emission control of diesel engine systems for use in underground coal mines.

1988-01-01

265

A DNA recombinant database management system.  

UK PubMed Central (United Kingdom)

A set of computer programs is described which constitutes a clone database management system. Maintenance of the database and the stocks of material is designed to be under the control of one person...Full Text Available

1983-07-11

266

Self installable: floating production facility requires only light support craft  

Energy Technology Data Exchange (ETDEWEB)

An integrated multiwell floating production, storage, and offloading (FPSO) facility was successfully installed at the Tazerka field offshore Tunisia in 1982. Because there is good reason to believe that the installation techniques developed for the Tazerka FPSO can be applied to even larger systems in deeper waters, this paper presents the design and step-by-step installation procedures developed at Tazerka.

1983-05-01

267

Quality assurance requirements for the design of nuclear fuel reprocessing facilities  

International Nuclear Information System (INIS)

Requirements and guidance are provided for a quality assurance program for the design of nuclear fuel reprocessing facilities involving structures, systems and components whose satisfactory performance is required to prevent accidents that could cause undue risk to the health and safety of the public, or to mitigate the consequences of such accidents if they were to occur. The standard is to be used in conjunction with ANSI N46.2.

268

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

269

Offshore: North Sea facility gets the CETCO solution  

British Library Electronic Table of Contents (United Kingdom)

CETCO Oilfield Services, suppliers of environmental systems, have undertaken a project to treat contaminated water returns on a Floating, Production, Storage and Offloading (FPSO) facility in the North Sea. The solution sees fluids treated during oil well clean-up operations, reducing the potential for overboard oil discharges, and resulting production upsets.

2006-01-01

270

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

271

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

272

Green design focus: Energy efficiency and environmental responsibility  

Energy Technology Data Exchange (ETDEWEB)

This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.

1998-02-01

273

Drilling on the basis of reliable data. Geothermal exploration; Bohren nach verlaesslichen Planungsdaten. Geothermie  

Energy Technology Data Exchange (ETDEWEB)

Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)

2008-01-15

274

Stabilization of synchrotron radiation beam at HASYLAB  

Energy Technology Data Exchange (ETDEWEB)

At DORIS II/HASYLAB a vertical beam position control system is in regular operation. It controls the position and angle of a photon beam simultaneously, and can stabilize beam movements up to frequencies of 0.1 Hz. To suppress beam vibrations up to 50 Hz and above, a prototype beam stabilization system for these frequencies was built and tested successfully. The present beam oscillations at the HASYLAB beamlines are explained, the quality of the beam position control system and the results of the prototype test are presented.

1989-07-01

275

Development of Auto-tuning System for the Process Optimal Control of Wolsung NPP.  

Science.gov (United States)

This was written as the research final report of (sup D)evelopment of Auto- tuning System for the Process Optimal Control of Wolsung NPP(sup ()95ZS13). In this research, a new PID controller auto-tuning algorithm and Auto-tuning System which can simulate ...

1997-01-01

276

Proton beam therapy control system  

Energy Technology Data Exchange (ETDEWEB)

A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.

2010-09-21

277

Off peak geothermal heat pump storage system  

Energy Technology Data Exchange (ETDEWEB)

The basic design of a system installed in the Columbus, Ohio Zoo is described. The distribution system is described in detail. The control system is microprocessor controlled, with about 50 monitoring points. Preliminary evaluations have indicated that the system can operate with an overall coefficient of performance in excess of 3.5. 1 figure.

1986-03-01

278

Instrumentation and control improvements at Experimental Breeder Reactor II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe instrumentation and control (I C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I C systems of the next generation of liquid metal reactor (LMR) plants.

1993-01-01

279

Instrumentation and control improvements at Experimental Breeder Reactor II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe instrumentation and control (I&C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I&C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I&C systems of the next generation of liquid metal reactor (LMR) plants.

1993-03-01

280

Control and monitoring of solar thermal systems with networked embedded systems  

Energy Technology Data Exchange (ETDEWEB)

Within this paper the potentialities of using networked embedded systems will be discussed. New embedded hardware with network connectivity allows remote administration and software updates of solar thermal system controllers via internet. System self analysis helps to minimize breakdown times by sending email and SMS to request maintenance staff. (orig.)

2004-07-01

281

State of work for services provided by the Waste Sampling and Characterization Facility for effluent monitoring  

International Nuclear Information System (INIS)

This document defines the services the Waste Sampling and Characterization Facility (WSCF) shall provide Effluent Monitoring (EM) throughout the calendar year for analysis. The internal memo contained in Appendix A identifies the samples Em plans to submit for analysis in CY-1995. Analysis of effluent (liquid and air discharges) and environmental (air, liquid, animal, and vegetative) samples is required using standard laboratory procedures, in accordance with regulatory and control requirements. This report describes regulatory reporting requirements and WSCF services and data quality objectives.

282

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

283

Energy-Smart Building Choices: How School Facilities Managers and Business Officials Are Reducing Operating Costs and Saving Money  

Science.gov (United States)

Most K-12 schools could save 25% of their energy costs by being smart about energy. Nationwide, the savings potential is $6 billion. While improving energy use in buildings and busses, schools are likely to create better places for teaching and learning, with better lighting, temperature control, acoustics, and air quality. This brochure, targeted to school facilities managers and business officials, describes how schools can become more energy efficient.

2001-08-06

284

Status of PACTEL facility  

Energy Technology Data Exchange (ETDEWEB)

Since 1976, the Nuclear Engineering Laboratory of the Technical Research Centre of Finland and Lappeenranta University of Technology have cooperated in the field of nuclear reactor thermal-hydraulics. During these years, a series of experimental facilities (REWET-I, -II, -III, VEERA) simulating pressurized water reactors (PWRs) have been built. The newest facility, PACTEL (Parallel Channel Test Loop), is an experimental out-of-pile facility designed to simulate the major components and system behaviour of a commercial PWR during postulated small and medium size break loss-of-coolant accidents (LOCAs), natural circulation and operational transients. A PACTEL natural circulation experiment has been carried out as an OECD/NEA international standard problem ISP 33. (2 refs., 3 figs., 2 tabs.).

1993-12-31

285

Hot Cell Facility (HCF) Safety Analysis Report  

Energy Technology Data Exchange (ETDEWEB)

This Safety Analysis Report (SAR) is prepared in compliance with the requirements of DOE Order 5480.23, Nuclear Safety Analysis Reports, and has been written to the format and content guide of DOE-STD-3009-94 Preparation Guide for U. S. Department of Energy Nonreactor Nuclear Safety Analysis Reports. The Hot Cell Facility is a Hazard Category 2 nonreactor nuclear facility, and is operated by Sandia National Laboratories for the Department of Energy. This SAR provides a description of the HCF and its operations, an assessment of the hazards and potential accidents which may occur in the facility. The potential consequences and likelihood of these accidents are analyzed and described. Using the process and criteria described in DOE-STD-3009-94, safety-related structures, systems and components are identified, and the important safety functions of each SSC are described. Additionally, information which ...

2000-11-01

286

Experimental assessment of energy storage via variable speed compressor  

British Library Electronic Table of Contents (United Kingdom)

In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of ...

2011-01-01

287

Advanced Monitoring and Control of Multi monomer System in Emulsion Polymerization  

British Library Electronic Table of Contents (United Kingdom)

Abstract A control framework was developed for real time implementation of optimal control of emulsion polymerization with multiple monomers by integrating model based algorithms with software engines. The developed system was applied for controlling conversion, particle size, molar mass, and polymer composition using model predictive control (MPC) based on mechanistic models for emulsion polymerization. The control formulation was extended to account for existing process constraints on the input, input moves, and solids content. On experimental testing, the developed control scheme was found to achieve the desired objectives without violating the process constraints and showed good robustness in rejecting disturbances. Improvements in the process operation and polymer property control wer...

2010-01-01

288

Status of safety at Areva group facilities. 2007 annual report; Areva, etat de surete des installations nucleaires. Rapport annuel 2007  

Energy Technology Data Exchange (ETDEWEB)

This report describes the status of nuclear safety and radiation protection in the facilities of the AREVA group and gives information on radiation protection in the service operations, as observed through the inspection programs and analyses carried out by the General Inspectorate in 2007. Having been submitted to the group's Supervisory Board, this report is sent to the bodies representing the personnel. Content: 1 - A look back at 2007 by the AREVA General Inspector: Visible progress in 2007, Implementation of the Nuclear Safety Charter, Notable events; 2 - Status of nuclear safety and radiation protection in the nuclear facilities and service operations: Personnel radiation protection, Event tracking, Service operations, Criticality control, Radioactive waste and effluent management; 3 - Performance improvement actions; 4 - Description of the General Inspectorate; 5 - Glossary.

2007-07-01

289

Reference equilibrium core with central flux irradiation facility for Pakistan research reactor-1  

International Nuclear Information System (INIS)

In order to assess various core parameters a reference equilibrium core with Low Enriched Uranium (LEU) fuel for Pakistan Research Reactor (PARR-1) was assembled. Due to increased volume of reference core, the average neutron flux reduced as compared to the first higher power operation. To get a higher neutron flux an irradiation facility was created in centre of the reference equilibrium core where the advantage of the neutron flux peaking was taken. Various low power experiments were performed in order to evaluate control rods worth and neutron flux mapping inside the core. The neutron flux inside the central irradiation facility almost doubled. With this arrangement reactor operation time was cut down from 72 hours to 48 hours for the production of the required specific radioactivity. (author)

2008-07-01

290

Air conditioner for radioactive material handling facility  

Energy Technology Data Exchange (ETDEWEB)

An air conditioner intakes open-air from an open-air intake port to remove sands and sea salt particles by air filters. Then, natural and artificial radioactive particles of less than 1 {mu}m are removed by high performance particulate filters. After controlling the temperature by an air heater or an air cooler, air is sent to each of chambers in a facility under pressure elevation by a blower. In this case, glass fibers are used as the filter material for the high performance particulate filter, which has a performance of more than 99.97% for the particles of 0.3 {mu}m grain size. Since this can sufficiently remove the natural radioactive materials intruded from the outside, a detection limit value in each of the chambers of the facility can be set 10{sup -13} to 10{sup -14} {mu}ci/cm{sup 3} in respect of radiation control. Accordingly, radiation control can be conducted smoothly ...

1991-04-26

291

Maintenance implementation plan for the B Plant/WESF. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the B Plant/WESF (Waste Encapsulation Storage Facility) complex. The objective of this plan is to provide baseline information for establishing and identifying WHC conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at B Plant/WESF. The B Plant WESF facility complex consists of three main facilities and several support structures located in the 200 East Area of the Hanford site. B Plant is a transition facility that is required to ensure safe storage and management of WESF (operating facility) cesium and strontium capsules. B Plant/WESF also contains substantial radiological inventory from previous campaigns. ...

1996-01-01

292

An adaptive power system stabilizer based on the self-optimizing pole shifting control strategy  

Energy Technology Data Exchange (ETDEWEB)

An adaptive power system stabilizer (APSS) employing a new self-optimizing pole shifting control strategy and its application to a power system are described in this paper. Based on an identified model of the system, the control is computed by an algorithm which shifts the closed-loop poles of the system to some optimal locations inside the unit circle in the z-domain to minimize a given performance criterion. With the self-optimization property, outside intervention in the controller design procedure is minimized, thus simplifying the tuning procedure during commissioning. Also, a new method of calculating the variable forgetting factor in real-time parameter identification is discussed. Studies show that the proposed APSS can provide good damping of the power system over a wide operating range and significantly improve ...

1993-12-01

293

A study on the response time characteristics related to shock control in the hydraulic system using the fluid device  

International Nuclear Information System (INIS)

Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.

2001-11-01

294

Performance improvement by control of flow rates and diesel injection timing on dual-fuel engine with ethanol  

Energy Technology Data Exchange (ETDEWEB)

To utilize ethanol from agricultural residue as a fuel in diesel engines, a dual-fuel engine was developed. The engine, which was equipped with a system to electrically control diesel and alcohol flow rates, met basic requirements of a tractor engine, including engine speed control and setting of the torque curve. However, engine knock due to alcohol was a significant drawback. A diesel injection pump with a timing and flow rate control system was adapted, and the effect of injection timing on combustion and performance was investigated. It was observed that the timing control was effective in reducing engine knock caused by rapid alcohol combustion. (author)

1996-04-01

295

PSS and TCSC damping controller coordinated design using PSO in multi-machine power system  

International Nuclear Information System (INIS)

The paper develops a new design procedure for simultaneous coordinated designing of the thyristor controlled series capacitor (TCSC) damping controller and power system stabilizer (PSS) in multi-machine power system. The coordinated design problem of PSS and TCSC damping controllers over a wide range of loading conditions is converted to an optimization problem with the time domain-based objective function that is solved by a particle swarm optimization (PSO) technique which has a strong ability to find the most optimistic results. By minimizing the proposed fitness function in which oscillatory characteristics between areas are included and thus the interactions among the TCSC controller and PSS under transient conditions in the multi-machine power system are improved. To ensure the robustness of the proposed stabilizers, the design process ...

2010-12-01

296

A study on the power system stabilizer using discrete-time adaptive sliding mode control  

Energy Technology Data Exchange (ETDEWEB)

In this paper the newly developed discrete-time adaptive sliding mode control method is proposed and applied to the power system stabilization problem. In contrast to the conventional continuous-time sliding mode controller, the proposed method is developed in the discrete-time domain and based on the input/output measurements instead of the continuous-time and the full-states feedback, respectively. Because the proposed control method has the adaptivity property in addition to the natural robustness property of the sliding mode control, it is possible to design the power system stabilizer which can overcome both the minor variations of the parameters of the power system and the diverse operating conditions and faults of the power system. Mathematical proof and the various computer simulations are done to verify the ...

1996-02-01

297

Thin-film evaporator recovers solvents continuously  

Energy Technology Data Exchange (ETDEWEB)

Reclaimed Energy Company, Inc., Connersville, IN, receives waste generated from a wide variety of industrial applications which include paint, printing and degreasing companies. The wastes are stored in separate tanks and then distilled in batches (pot distillation). The recovered solvents can be returned to the originator. The residue, left after the solvents are distilled, is disposed of using an environmentally safe, economical procedure. The company worked with an engineering and fabrication firm to develop a continuous processing system that employs a mechanically agitated thin-film evaporator to distill the solvents. Successful performance of the evaporator was ensured by processing samples of solvents through the evaporator manufacturer's pilot plant facilities before the full-sized system was designed. Reclaimed Energy Company, Inc., has realized a number of advantages by going from pot distillation to the ...

1985-11-01

298

Methods and results for calibration and track separation of a GEM based TPC using an UV-laser  

Energy Technology Data Exchange (ETDEWEB)

In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to be able to identify ...

2008-12-15

299

Waste Handeling Building Conceptual Study  

Energy Technology Data Exchange (ETDEWEB)

The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options ...

2000-11-06

300

Utility of Recycled Bedding for Laboratory Rodents  

UK PubMed Central (United Kingdom)

Animal facilities generate a large amount of used bedding containing excrement as medical waste. We developed a recycling system for used bedding that involves soft hydrothermal processing. In this...Full Text Available

2009-07-01

301

Developing a Performance Measurement Framework and Indicators for Community Health Service Facilities in Urban China  

UK PubMed Central (United Kingdom)

BackgroundChina has had no effective and systematic information system to provide guidance for strengthening PHC (Primary Health Care) or account to citizens on progress. We report...Full Text Available

302

Analyses of eigenvalue bias and control rod worths in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) core loading during its ninth operating cycle was significantly different from that of previous cycles because of the presence of the Core Demonstration Experiment (CDE). The CDE consists of a number of axially blanketed fuel assemblies and internal blankets prototypic of advanced oxide cores in Liquid Metal Reactors (LMR). In preparation for the Cycle 9 reload design effort, a careful assessment of control rod worth and reactivity calculations for Cycles 1 through 8 was made. The goal of this study was to establish calculational biases and reduce uncertainties factored into the reload design calculations. These analyses helped assure that the operational objectives for Cycle 9 were met.

1987-09-13

303

Analyses of eigenvalue bias and control rod worths in FFTF (Fast Flux Test Facility)  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) core loading during its ninth operating cycle was significantly different from that of previous cycles because of the presence of the Core Demonstration Experiment (CDE). The CDE consists of a number of axially blanketed fuel assemblies and internal blankets prototypic of advanced oxide cores in Liquid Metal Reactors (LMR). In preparation for the Cycle 9 reload design effort, a careful assessment of control rod worth and reactivity calculations for Cycles 1 through 8 was made. The goal of this study was to establish calculational biases and reduce uncertainties factored into the reload design calculations. These analyses helped assure that the operational objectives for Cycle 9 were met.

1987-01-01

304

Power system stabilizer design based on the pole assignment technique for SIMO systems. [Single-input multi-input  

Energy Technology Data Exchange (ETDEWEB)

A new power system stabilizer (PSS) design method for single-machine infinite-bus systems is developed. This design method not only assigns the poles corresponding to the electro-mechanical oscillation modes in the system, but also located other system poles in suitable places in the s-plane. The design procedure is used first to translate a PSS design problem to an equivalent constant output feedback controller design problem for a single-input multi-output (SIMO) system. Then, a new algorithm developed in this paper is applied to design a constant output feedback controller to achieve the desired closed-loop system pole locations. Finally, the controller gains are transferred back to the parameters in the PSS. The extension of the method to multi-machine power systems is also ...

1991-12-01

305

Fiscal 1997 report on the results of the international standardization R and D. Robot control system; 1997 nendo seika hokokusho kokusai hyojun soseigata kenkyu kaihatsu. Robot seigyo system  

Energy Technology Data Exchange (ETDEWEB)

R and D of the robot control system was conducted in the following items: 1) integrated open control system, 2) remote control robot manipulation language, 3) human factor robot use built-in LAN system, 4) built-in actuator driver. In 1), there were some problems to be pointed out around the system, but the effectiveness was confirmed as system architecture of each verification item. In 2), development/design were made of RCML(R-Cube Manipulation Language) as a remote robot manipulation language, telecommunication protocol, and the experimental system, and the international standardization was targeted. In 3), the R and D was conducted of the realtime telecommunication protocol which clears the standards for the distributed control required for construction of human factor robot ...

1998-03-01

306

Prospective application of advanced series compensation to improve transmission system performance  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the main aspects and results of the planning studies undertaken to evaluate the technical benefits of using Thyristor Controlled Series Compensation (TCSC), in a large 500 kV transmission system (Brazilian North-Northeast system). TCSC controllers design and simplified models for digital non-linear time domain simulations are discussed. The proposed controllers are tuned and used to support the comparative analysis between controlled and fixed series compensation. The relevant conclusions concerning this comparison are highlighted. (author) 2 refs., 14 figs., 3 tabs.

1994-12-31

307

Comparison of fuzzy control systems for hypothermal brain temperature regulation  

British Library Electronic Table of Contents (United Kingdom)

The automatic control system for brain tissue temperature is studied theoretically for brain hypothermia treatment. In order to realize a human-friendly control mechanism, an automatic temperature regulation system is constructed to simulate brain hypothermia treatment by introducing a fuzzy algorithm for possible characteristic changes in patients. The brain temperature model is successfully realized to follow the desired temperature course automatically. The model reference fuzzy control of brain temperature based on water-cooling blankets is verified for clinical application to brain hypothermia treatments through various kinds of simulation experiment.

2007-01-01

308

Automatic-control system for the 17-metre vertical-axis wind turbine (VAWT)  

Science.gov (United States)

The 17-metre DOE/Sandia VAWT began operation in March 1977. Since that time the turbine has been operated strictly by manual control for the purpose of data acquisition and performance analysis; this procedure has limited the VAWT operation time and power output. An automatic-control system has been designed and implemented to study automatic control of a VAWT and to better judge the fatigue life and reliability of the VAWT under what will be normal operating conditions for power production. This system, including the necessary hardware, is discussed in detail along with a simplified cost analysis.

1980-03-01

309

A self-organizing power system stabilizer using Fuzzy Auto-Regressive Moving Average (FARMA) model  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a self-organizing power system stabilizer (SOPSS) which use the Fuzzy Auto-Regressive Moving Average (FARMA) model. The control rules and the membership functions of the proposed logic controller are generated automatically without using any plant model. The generated rules are stored in the fuzzy rule space and updated on-line by a self-organizing procedure. To show the effectiveness of the proposed controller, comparison with a conventional controller for one-machine infinite-bus system is presented.

1996-06-01

310

Performance of static var compensator control type thyristor controlled reactor and thyristor switched capacitor  

Energy Technology Data Exchange (ETDEWEB)

This paper has the objective of presenting the philosophy of Static Var Compensator (SVC) Control as well the necessary adjustments in the project of control system to guarantee suitable performance under different operating conditions. The verification on the performance of the SVC control has been done by Transient Network Analyzer (TNA/CEPEL) studies, commissioning tests and a factory tests. The SVC is the type of Thyristor Controlled Reactor (TCR) and Thyristor Switched Capacitor (TSC). (author) 3 refs., 12 figs.

1994-12-31

311

MTF analysis of the near-real time neutron radiography facility at MURR  

International Nuclear Information System (INIS)

Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).

1981-12-01

312

Estimating the tritiated hydrocarbon decontamination factor by heavy methane  

International Nuclear Information System (INIS)

As part of the start up of Los Alamos National Laboratory's new tritium-handling facility, the efficiency of a catalytic oxidation tritium decontamination system was investigated using deuterated methane. The tests were performed during the start up of the facility to confirm the operability of the system before introducing tritium and to provide a baseline for comparison. Techniques and instruments normally used for atmospheric tracer experiments using deuterated methane were applied virtually without modification. The sensitivity of this method allowed preliminary checks at the sub-ppm (v/v) level.

313

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

314

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

315

Acceptance test report for the Westinghouse 100 ton hydraulic trailer  

Energy Technology Data Exchange (ETDEWEB)

The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.

1995-03-06

316

Electronic system hardening methodology  

International Nuclear Information System (INIS)

The notion of hardened systems can be found in several applications (nuclear power plants, alarm systems, research installations..). Their development correspond to the functional necessity to take into account a specific radiative environment. The starting point of each hardening study is the definition of the radiative environmental constraints representative of the application. In addition to these external constraints, the specific functional characteristics of each system are considered: control or interface systems in nuclear industry, in-board control systems, remote handling systems, etc. This paper summarizes the methodology followed according to the experience gained in previous studies and anticipating the future needs. (J.S.). 6 refs., 5 figs.

317

The PANDA tests for SBWR certification  

International Nuclear Information System (INIS)

The ALPHA project is centered around the experimental and analytical investigation of the long-term decay heat removal from the containments of the next generation of open-quotes passiveclose quotes ALWRs. The project includes integral system tests in the large-scale (1:25 in volume) PANDA facility as well as several other series of tests and supporting analytical work. The first series of experiments to be conducted in PANDA have become a required experimental element in the certification process for the General Electric Simplified Boiling Water Reactor (SBWR). The PANDA general experimental philosophy, facility design, scaling, and instrumentation are described. Steady-state PCCS condenser performance tests and extensive facility characterization tests were already conducted. The transient system behavior tests are underway; preliminary results from the first transient test M3 are ...

1996-03-01

318

Development of in-vessel reflood instrumentation at ORNL  

International Nuclear Information System (INIS)

A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument ...

2004-09-06

319

Application of probabilistic methods to accident analysis at waste management facilities  

International Nuclear Information System (INIS)

Probabilistic risk assessment is a technique used to systematically analyze complex technical systems, such as nuclear waste management facilities, in order to identify and measure their public health, environmental, and economic risks. Probabilistic techniques have been utilized at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, to evaluate the probability of a catastrophic waste hoist accident. A probability model was developed to represent the hoisting system, and fault trees were constructed to identify potential sequences of events that could result in a hoist accident. Quantification of the fault trees using statistics compiled by the Mine Safety and Health Administration (MSHA) indicated that the annual probability of a catastrophic hoist accident at WIPP is less than one in 60 million. This result allowed classification of a catastrophic hoist accident as ''not credible'' at WIPP per DOE ...

320

Electrical equipment of the Marchtrenk power station on the river Traun  

Energy Technology Data Exchange (ETDEWEB)

By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.

1982-03-01

321

Development of requirements tracking and verification system for the software design of distributed control system  

Energy Technology Data Exchange (ETDEWEB)

In this paper a prototype of Requirement Tracking and Verification System(RTVS) for a Distributed Control System was implemented and tested. The RTVS is a software design and verification tool. The main functions required by the RTVS are managing, tracking and verification of the software requirements listed in the documentation of the DCS. The analysis of DCS software design procedures and interfaces with documents were performed to define the user of the RTVS, and the design requirements for RTVS were developed. 4 refs., 3 figs. (Author)

1998-12-31

322

An intelligent management system for corporate information- calculating network development  

CERN Document Server

An approach to solving the problem of managerial control quality improvement corporate information-calculating networks (CICN) is proposed. The approach is based on the concept of a flexible toolkit. A macro-model, system-science and system-engineering models of an intelligent managerial control system (IMCS) for CICN development are considered as well as its dynamics. The practical opportunity of IMCS implementation is assessed. (5 refs).

2001-01-01

323

Modeling and control of a novel heat exchange reactor, the Open Plate Reactor  

British Library Electronic Table of Contents (United Kingdom)

A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...

2007-01-01

324

Identification and robust water level control of horizontal steam generators using quantitative feedback theory  

British Library Electronic Table of Contents (United Kingdom)

In this paper, a robust water level control system for the horizontal steam generator (SG) using the quantitative feedback theory (QFT) method is presented. To design a robust QFT controller for the nonlinear uncertain SG, control oriented linear models are identified. Then, the nonlinear system is modeled as an uncertain linear time invariant (LTI) system. The robust designed controller is applied to the nonlinear plant model. This nonlinear model is based on a locally linear neuro-fuzzy (LLNF) model. This model is trained using the locally linear model tree (LOLIMOT) algorithm. Finally, simulation results are employed to show the effectiveness of the designed QFT level controller. It is shown that it will ensure the entire designer's water level closed loop specifications.

2011-01-01

325

Development of a survey-design support sytem using soil data base; Doshitsu data base wo mochiita chosa sekkei shien system no kaihatsu ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

It is desired that the data on past ground information are easily picked out and used effectively when construction of power facilities such as power plants is planned. For this purpose, a data base system that is available for survey planning and design business has been developed. This system is divided into subsystems for input, registration, and output, which all can be processed by the personal computers. It also has a retrieval function for maps such as area maps and power facility maps in addition to a retrieval function for characters. As output functions, the system has a function to extract ground information through maps of facilities and their peripheries, an output function for geological profiles and soil test results, and liquefaction analysis and design constant setting support functions. As instances, applications of this ...

1994-09-05

326

Design and procurement report for the FFTF fuel handling systems bottom-loading transfer cask  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) bottom-loading transfer cask (BLTC) system is designed to provide ex-vessel fuel transfers of irradiated reactor components between the reactor containment building and the LMFBR shipping cask in the reactor service building. This system is being procured from National Lead Industries, Wilmington, Delaware, under management of Aerojet Manufacturing Company.

1975-11-16

327

Vortex control of safety enclosures  

International Nuclear Information System (INIS)

The vortex amplifier controller has no moving parts and therefore it can have extremely high reliability and avoid the maintenance problems associated with contaminated equipment. The vortex amplifier and its application to ventilation control of radioactive enclosures is described. Reverse purge vortex amplifier ventilation system control is also discussed. (U.K.).

328

A Study on the Power System Stabilizer Design using Object-Oriented Method  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we have designed power system stabilizer (PSS) using object-oriented method. There are several types of power system stabilizer, A proportional-integral (PI) controller is very simple for practical implementation. Therefore it has been widely employed by the industry. The methods of obtaining the gains (Ki,Kp) of PI controller are root-locus method and sub-optimal regulator approach. But these methods are cannot be applicable to nonlinear system and faulted power system. So we proposed a new method which can be applied to nonlinear system by numerical analysis method. The method of dynamic system simulation by numerical method is very difficult and complex. We proposed flexible simulation method for complex power system analysis using object-oriented programming (OOP) and applied to PI ...

1999-06-01

329

Superconducting magnetic system with the controllable inductance of a winding  

International Nuclear Information System (INIS)

The experimental superconducting magnetic system of 0.5 MJ energy storage is described. The step variation of the winding inductance provides a control by the discharge current at the energy output on a high-ohmic load. The voltage on a load is 45 kV at the current 1100 A under the controllable discharge conditions. The energy transfer coefficient constitutes 0,76 under the maximum-to-minimal current ratio equal to 1.3. 7 refs., 3 figs., 2 tabs.

330

Acceptance test guideline for steam turbine control systems. Anahmerichtlinie fuer Regel- und Steuereinrichtungen von Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

The acceptances to be obtained during the first operational run, refer to measures proving the functional integrity of the turbine control system and assuring the compliance with the maximum allowable overspeed in case of lead changes or perturbations. The Guideline concerns essentially speed, power, and pressure controllers coupled to generators. It may be appropriately extended to steam turbines serving other purposes.

1983-01-01

331

Needs and possibilities of founding electric power dispatchers offices in coal mines. [Poland  

Energy Technology Data Exchange (ETDEWEB)

Energy consumption of black coal mines in Poland and methods for energy conservation are evaluated. Organizational models of energy management in underground coal mining are discussed. Tasks for dispatcher service for energy consumption control in a coal mine are analyzed: control of energy supplies, control of energy consumption, evaluation of electrical failures and reliability of protection systems, recording accidents and analyzing their causes, optimization of power systems in underground mines. Problems associated with control of energy consumption in a coal mine with mechanized systems for coal mining and use of computerized control systems are discussed. Recommendations for reucing energy consumption in underground coal mining are made. 4 references.

1985-05-01

332

Enhanced power system stabilizer via integrated tabu-fuzzy knowledge based controller  

Energy Technology Data Exchange (ETDEWEB)

An integrated tabu-fuzzy knowledge based controller applied to enhance the performance of power system stabilizer (PSS) is presented in this paper. The fuzzy knowledge based controller (FKBC) has been developed to perform the function of a PSS and to provide a supplementary signal to the excitation system of the synchronous generator. The method used for storing and representing the fuzzy rules is called the fuzzy associative memory (FAM) matrix. The well-defined FAM determines the performance of the FKBC and hence the tabu search algorithm is proposed and applied to determine the construction and optimization of the FAM. The controller has been tested in the case of single machine infinite bus and multi-machine systems for various types of disturbance. To show the effectiveness of the proposed controller, the comparison with the ...

2003-09-01

333

MIMO (multi-input multi-output) adaptive power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A multivariate adaptive power system stabilizer is proposed. The advantages of using coordinated governor and excitation control are discussed, and the problems associated with constant parameter power system stabilizers (CPSS) are highlighted. The proposed multi-input multi-output (MIMO) power system stabilizer can coordinate the governor and excitation control and can overcome the problems associated with CPSS in power system stabilization. Selective multivariable state modelling, identification and control methods are investigated and the MIMO least squares technique with variable forgetting factor is used for system identification, guaranteeing good parameter tracking after a disturbance. Two multivariable self-tuning algorithms are investigated, the generalized minimum variance control and ...

1988-01-01

334

Decommissioning of U.S. uranium production facilities  

Energy Technology Data Exchange (ETDEWEB)

From 1980 to 1993, the domestic production of uranium declined from almost 44 million pounds U{sub 3}O{sub 8} to about 3 million pounds. This retrenchment of the U.S. uranium industry resulted in the permanent closing of many uranium-producing facilities. Current low uranium prices, excess world supply, and low expectations for future uranium demand indicate that it is unlikely existing plants will be reopened. Because of this situation, these facilities eventually will have to be decommissioned. The Uranium Mill Tailings and Radiation Control Act of 1978 (UMTRCA) vests the U.S. Environmental Protection Agency (EPA) with overall responsibility for establishing environmental standards for decommissioning of uranium production facilities. UMTRCA also gave the U.S. Nuclear Regulatory Commission (NRC) the responsibility for licensing and regulating uranium production and related activities, including ...

1995-02-01

335

Error evaluation of the linearized equation of servo valve in hydraulic control systems  

International Nuclear Information System (INIS)

In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.

2001-11-01

336

Digital AVR application to power plants  

Energy Technology Data Exchange (ETDEWEB)

The digital AVR must have the level of redundancy and control functions that conform to the configuration of the excitation control system and to the importance of a particular generator for the user. The digital AVR is not simply a digital version of the analog AVR, but can realize sophisticated control functions that were difficult to achieve with analog circuits, thus making it possible to enhance the stability of power system by PSS (power system stabilizer). This paper describes the test results of the digital AVRs applied to power plants, their system configuration and functions, as well as the outline of an auto-tuning PSS or AT-PSS planned to be incorporated in the digital AVR in the future.

1993-12-01

337

FFTF reactor assembly system technology  

Science.gov (United States)

An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs. (DG)

1975-11-13

338

FFTF reactor assembly system technology  

International Nuclear Information System (INIS)

An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs.

1976-03-13

339

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

340

Savannah River Site dose control  

Energy Technology Data Exchange (ETDEWEB)

Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.

1992-01-01

341

Savannah River Site dose control  

Energy Technology Data Exchange (ETDEWEB)

Health physicists from the Brookhaven National Laboratory (BNL) visited the Savannah River Site (SRS) as one of 12 facilities operated by the Department of Energy (DOE) contractors with annual collective dose equivalents greater than 100 person-rem (100 person-cSv). Their charter was to review, evaluate and summarize as low as reasonably achievable (ALARA) techniques, methods and practices as implemented. This presentation gives an overview of the two selected ALARA practices implemented at the SRS: Administrative Exposure Limits and Goal Setting. These dose control methods are used to assure that individual and collective occupational doses are ALARA and within regulatory limits.

1992-06-01

342

Robotics and teleoperator-controlled devices  

International Nuclear Information System (INIS)

This paper presents a rationale for and a summary of tasks and missions to which mobile and stationary robots and other teleoperator-controlled devices could be assigned in response to the accidental release of radioactive and other hazardous/toxic materials to the environment. Many of these vehicles and devices currently support operation and maintenance of nuclear power plants and other nuclear industry facilities. This paper also discusses specific missions for these devices at the Three Mile Island and Chernobyl nuclear power plant sites at the time of the accidents. Also discussed is the status of devices under development for future applications, as well as research on robotics.

343

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

344

Radiological considerations of the reactor cover gas processing system at the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

Radiological and environmental protection experience associated with the reactor cover gas processing system at the Fast Flux Test Facility (FFTF) has been excellent. Personnel radiation exposures received from operating and maintaining the reactor cover gas processing system have been very low, the system has remained free of radioactive particulate contamination through the first seven operating cycles (cesium contamination was detected at the end of Cycle 8A), and releases of radioactivity to the environment have been very low, well below environmental standards. This report discusses these three aspects of fast reactor cover gas purification over the first eight operating cycles of the FFTF (a duration of a little more than four years, from April 1982 through July 1986).

1986-09-24

345

Learning and case-based reasoning for faults diagnosis-aiding in nuclear power plants  

International Nuclear Information System (INIS)

The aim of this thesis is the design of a faults diagnosis-aiding system in a nuclear facility of the Cea. Actually the existing system allows the optimization of the production processes in regular operating conditions. Meanwhile during accidental events, the alarms, managed by threshold, are bringing no relevant information. To increase the reliability and the safety, the human operator needs a faults diagnosis-aiding system. The developed system, SECAPI, combines problem solving techniques and automatic learning techniques, that allow the diagnosis and the the simulation of various faults happening on nuclear facilities. Its reasoning principle uses case-based and rules-based techniques. SECAPI owns a learning module which reads out knowledge connected with faults. It can then simulate various faults, using the inductive logical computing. SECAPI has been ...

1998-01-01

346

Transient Critical Heat Flux tests on a rod bundle simulating Pressurized Water Reactors  

International Nuclear Information System (INIS)

Transients induced in nuclear power plants from many sources result in one or more fluid conditions changing with time. Fluid conditions of pressure, inlet temperature, inlet flow, or even system power many change separately or in conjunction with each other. The result of the condition change may be one which induces departure from nucleate boiling. An experimental investigation of transient which were intended to achieve Critical Heat Flux was performed at the Heat Transfer Research Facility of Columbia University for Siemens Nuclear Power Corporation. The transients were set up to include broad ranges of flow and pressure conditions near the operating range of pressurized water reactors. Transient events were dominated by varying single conditions and measuring the response of the system and of the rod thermocouples. Because of coupling effects within the test loop, secondary conditions would also vary. In order to ...

347

Application of neutron radiography systems in JRR-3M to nuclear engineering  

Energy Technology Data Exchange (ETDEWEB)

Initial major applications of neutron radiography (NR) to nuclear engineering were nondestructive inspections of nuclear fuel, control rods, reactor materials and some other components. Increase in the available neutron flux over 10{sup 8} n/cm{sup 2}s at the JRR-3M thermal neutron radiography facility (TNRF) in 1991 has expanded the application field to the dynamic but clear imaging of moving objects and fluid phenomena. The JRR-3M TNRF is facilitated with three major imaging systems, being characterized by spatial and/or temporal resolutions: 1. Static neutron radiography (SNR), 2. real-time neutron radiography (RNR) with an imaging rate of 30 frames/s and 3. High-frame-rate neutron radiography (HFRNR). SNR has been used for three-dimensional visualization of air-water two-phase flows in a simulated rod bundle. Three-dimensional computed tomography clearly illustrated average void fraction distributions around tie ...

1999-07-01

348

Assessing the effects of the HIPAA privacy rule on release of patient information by healthcare facilities.  

Science.gov (United States)

The HIPAA privacy rule (HIPAA) has had both positive and negative effects on the release of patient information by healthcare facilities. Although the intention of HIPAA was to protect patient privacy and to promote security and confidentiality of patient information, it has had unintended consequences for facilities. To identify some of these unintended effects, two expert panels of health information management directors from healthcare facilities participated in the nominal group technique meetings. They identified 70 barriers related to release of patient information associated with the implementation of HIPAA. The perceived biggest barriers were increases in the public's misunderstanding about release of patient information, lack of an umbrella policy or regulation defining infractions and enforcement that allows individual institutions to make their own interpretations, and challenges to health information management ...

2007-03-23

349

Power system stabilizer application in a two unit plant analytical studies and field tests  

Energy Technology Data Exchange (ETDEWEB)

The use of excitation system controls, specifically the Power System Stabilizer (PSS), to improve damping of power system oscillations and thus extend steady-state stability limits has been a subject of great interest in recent years. The desire to more fully utilize transmission capacity led to the installation of PSS controls on greater numbers of generating units to maintain stability margins. This paper addresses the tuning and adjustment of PSS controls in a two unit power plant. Both analytical studies and field test confirmations are presented. The practical difficulties of verifying the PSS control loop gain margin by testing are explored. A simplified procedure is outlined. The Lower Colorado River Authority (LCRA), Fayette Power Project (FPP) consists of two 683.7 MVA tandem compound steam turbine driven generators. The excitation ...

1983-02-01

350

Latest technologies for process control and automation in blast furnace; Korosogyo wo sasaeru saishin no purosesu seigyo to jidoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Kawasaki Steel has modernized blast furnace control systems featuring an integrated instrumentation and electrical system for each sub-process, a human-machine interface through a single window, and a distributed process computer system. A furnace diagnosis system, which has been known as 'GO-STOP system', has been developed to a knowledge-based system that enables to provide appropriate action guidance. For the burden distribution control, controllability and flexibility have been improved by the use of a bell-less-top charging device. For hot stove control, the automatic setting of a combustion gas flow rate and improved efficiency have been achieved by a fuzzy control system. Furthermore, the remote operation of cast ...

1999-12-01

351

Decentralized fuzzy control of multiple nonholonomic vehicles  

Energy Technology Data Exchange (ETDEWEB)

This work considers the problem of controlling multiple nonholonomic vehicles so that they converge to a scent source without colliding with each other. Since the control is to be implemented on simple 8-bit microcontrollers, fuzzy control rules are used to simplify a linear quadratic regulator control design. The inputs to the fuzzy controllers for each vehicle are the (noisy) direction to the source, the distance to the closest neighbor vehicle, and the direction to the closest vehicle. These directions are discretized into four values: Forward, Behind, Left, and Right, and the distance into three values: Near, Far, Gone. The values of the control at these discrete values are obtained based on the collision-avoidance repulsive forces and the change of variables that reduces the motion control problem of each nonholonomic vehicle to a ...

1997-09-01

352

The mixed waste management facility: Cost-benefit for the Mixed Waste Management Facility at Lawrence Livermore National Laboratory  

International Nuclear Information System (INIS)

The Mixed Waste Management Facility, or MWMF, has been proposed as a national testbed facility for the demonstration and evaluation of technologies that are alternatives to incineration for the treatment of mixed low-level waste. The facility design will enable evaluation of technologies at pilot scale, including all aspects of the processes, from receiving and feed preparation to the preparation of final forms for disposal. The MWMF will reduce the risk of deploying such technologies by addressing the following: (1) Engineering development and scale-up. (2) Process integration and activation of the treatment systems. (3) Permitting and stakeholder issues. In light of the severe financial constraints imposed on the DOE and federal programs, DOE/HQ requested a study to assess the cost benefit for the MWMF given other potential alternatives to meet waste treatment needs. The MVVMF Project was asked to ...

2005-10-01

353

A combined cycle engine test facility  

Energy Technology Data Exchange (ETDEWEB)

Rocket-Based Combined-Cycle (RBCC) engines intended for missiles and/or space launch applications incorporate features of rocket propulsion systems operating in concert with airbreathing engine cycles. Performance evaluation of these types of engines, which are intended to operate from static sea level take-off to supersonic cruise or accerlerate to orbit, requires ground test capabilities which integrate rocket component testing with airbreathing engine testing. A combined cycle engine test facility has been constructed in the General Applied Science Laboratories, Inc. (GASL) Aeropropulsion Test Laboratory to meet this requirement. The facility was designed to support the development of an innovative combined cycle engine concept which features a rocket based ramjet combustor. The test requirements included the ability to conduct tests in which the propulsive force was generated by rocket only, the ramjet only and ...

1995-09-01

354

Statistical support document for proposed effluent limitations guidelines and standards for the pulp, paper, and paperboard. Point source category  

Energy Technology Data Exchange (ETDEWEB)

The document describes the statistical analyses of data on pollutant loadings in effluent wastestreams from pulp, paper, and paperboard facilities. Included are the analyses that support the revised subcategorization and proposed effluent limitations for biochemical oxygen demand and total suspended solids based upon the best practicable control technology currently available.

1993-11-01

355

EPA (ENVIRONMENTAL PROTECTION AGENCY) MACROSCOPIC PLANNING MODEL (EPAMAC) FOR STORMWATER AND COMBINED SEWER OVERFLOW CONTROL: APPLICATION GUIDE AND USER'S MANUAL  

Science.gov (United States)

A simplified stormwater management model has been developed to provide an inexpensive, flexible tool for planning and preliminary sizing of stormwater facilities. The model was developed to be part of a methodology for use in the management of stormwater that utilizes both simple...

356

Activated charcoal. October 1976-August 1989 (Citations from the COMPENDEX data base). Report for October 1976-August 1989  

Energy Technology Data Exchange (ETDEWEB)

This bibliography contains citations concerning theoretical aspects and industrial applications of activated charcoal. Topics include absorption capacity and mechanism studies, kinetic and thermodynamic aspects, and properties descriptions and evaluations. Applications include utilzation in water analyses and waste treatment, air pollution control and measurement, and in nuclear facilities. (This updated bibliography contains 160 citations, 14 of which are new entries to the previous edition.)

1989-10-01

357

Activated charcoal. January 1970-October 1988 (Citations from the Compendex data base). Report for January 1970-October 1988  

Energy Technology Data Exchange (ETDEWEB)

This bibliography contains citations concerning theoretical aspects and industrial applications of activated charcoal. Topics include absorption capacity and mechanism studies, kinetic and thermodynamic aspects, and properties descriptions and evaluations. Applications include utilization in water analyses and waste treatment, air pollution control and measurement, and in nuclear facilities. (This updated bibliography contains 150 citations, 14 of which are new entries to the previous edition.)

1988-11-01

358

10 MWe Solar Thermal Central Receiver Pilot Plant: solar facilities design integration. Plant electrical equipment installation. Construction package No. 11 (RADL Item 7-35)  

Energy Technology Data Exchange (ETDEWEB)

Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.

1980-07-01

359

Reasons for decision in the matter of TransCanada PipeLines Limited. Motifs de decision (relative a) TransCanada Pipelines Limited; Volume 3. Installations, exportations de gaz et demandes deposees en vertu de l'article 71  

Energy Technology Data Exchange (ETDEWEB)

TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to ...

1991-04-01

360

Reasons for decision in the matter of TransCanada PipeLines Limited  

Energy Technology Data Exchange (ETDEWEB)

TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to ...

1991-04-01

361

Control of anodic passivation systems  

Energy Technology Data Exchange (ETDEWEB)

A method is described of controlling an anodic protection system in a heat exchanger comprising: (a) installing at least one cathode within the heat exchanger, at least one cathode being aligned with the longitudinal axis of the heat exchanger and extending substantially along the length of the heat exchanger; (b) installing a first reference electrode within and at one end of the heat exchanger, the first reference electrode having a first controller having a set point for control and a power supply having an output creating an electrical potential between at least one cathode and the heat exchanger; (c) measuring the electrical potential of the heat exchanger with the first reference electrode; (d) operating the first controller in response to measurements made by the first reference electrode to change the output of the power supply; (e) installing a second reference electrode ...

1987-08-25

362

Instrumentation and Controls Division progress report, July 1, 1982-July 1, 1984. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

Progress is briefly summarized for a large number of projects in the areas of research instruments, measurement and controls engineering, reactor systems, and maintenance management. (LEW)

1984-12-01

363

Electrical - light current remote monitoring, control and automation. [Coal mine, United Kingdom  

Energy Technology Data Exchange (ETDEWEB)

A brief discussion is given of the application of control monitoring and automation techniques to coal mining in the United Kingdom, especially of the use of microprocessors, for the purpose of enhancing safety and productivity. Lighting systems for the coal mine is similarly discussed.

1981-06-01

364

Dual fuel control of a high speed turbocharged diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The modification of a Ford 7600 turbocharged diesel engine to a dual fuel engine using methane as the supplementary fuel has been carried out. The paper describes the preliminary work of dual fuel control. Two systems are examined and their behaviour is presented.

1987-01-01

365

Development of compression-controlled low-level laser probe system: towards clinical application  

UK PubMed Central (United Kingdom)

Various physico-chemical tissue optical clearing (TOC) methods have been suggested to maximize photon density in tissue. In order to enhance photon density, a compression-controlled low-level...Full Text Available

2010-09-01

366

Design and Operating Parameters for Emission Control Studies: ASARCO, El Paso, Copper Smelter.  

Science.gov (United States)

The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO2 streams that curren...

1976-01-01

367

Automatic-Control System for the 17-Metre Vertical-Axis Wind Turbine (VAWT).  

Science.gov (United States)

The 17-metre DOE/Sandia VAWT began operation in March 1977. Since that time the turbine has been operated strictly by manual control for the purpose of data acquisition and performance analysis; this procedure has limited the VAWT operation time and power...

1980-01-01

368

The upgrade of nuclear material accounting system at KAERI  

International Nuclear Information System (INIS)

The agreement between the government of Republic Of Korea (ROK) and the IAEA for the application of safeguards was signed and entered into force in 1975. The Additional Protocol (AP) to the Safeguards Agreement between the ROK and the IAEA was signed in 1999 and entered into force on 19 February 2004. Also, Implementation of Integrated Safeguards (IS) was started on 1 July, 2008 after a draw of the broader conclusion. The IAEA provides 2 hours notification for Random Interim Inspection (RII) under IS. For RII, the facility has to prepare the inspection documents in a short time. Therefore, KAERI (Korea Atomic Energy Research Institute) developed a new computerized nuclear material accounting system named KASIS (KAERI Safeguards Information treatment System) to treat the data by on-line for RII. For the efficient IS implementation, KAERI has a plan to upgrade the system to reflect the accounting ...

2010-10-01

369

Systems Analysis of Safeguards Effectiveness in a Uranium Conversion Facility  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy (DOE) is interested in developing tools and methods for potential U.S. use in designing and evaluating safeguards systems. For this goal several DOE National Laboratories are defining the characteristics of typical facilities of several size scales, and the safeguards measures and instrumentation that could be applied. Lawrence Livermore National Laboratory is providing systems modeling and analysis of facility and safeguards operations, diversion path generation, and safeguards system effectiveness. The constituent elements of diversion scenarios are structured using directed graphs (digraphs) and fault trees. Safeguards indicator probabilities are based on sampling statistics and/or measurement accuracies. Scenarios are ranked based on value and quantity of material removed and the estimated probability of non-detection. Significant scenarios, ...

2004-06-16

370

Studies with a generalized neuron based Pss on a multi-machine power system  

International Nuclear Information System (INIS)

An artificial neural network can be used as an intelligent controller to control non-linear, dynamic system through learning. It can easily accommodate non-linearities and time dependencies. Most common multi-layer feed-forward neural networks have drawbacks of large number of neurons and hidden layers required to deal with complex problems and require large training time. To overcome these drawbacks, a generalized neuron based non-linear controller has been developed and illustrated as a power system stabilizer. Studies on a five-machine power system show that the proposed controller can significantly improve the dynamic performance and provide good damping of the power system over a wide operating range.

2004-07-01

371

Startup of the experimental physics industrial control system at NSTX  

Energy Technology Data Exchange (ETDEWEB)

The Experimental Physics Industrial Control System (EPICS) is a set of software which is being used as the basis of the National Spherical Torus Experiment's (NSTX) Process Control System, a major element of the NSTX's Central Instrumentation and Control System. EPICS is a result of a co-development effort started by several US Department of Energy National Laboratories. EPICS is actively supported through an international collaboration made up of government and industrial users. EPICS' good points include portability, scalability, and extensibility. A drawback for small experiments is that a wide range of software skills are necessary to get the software tools running for the process engineers. The authors' experience in designing, developing, operating, and maintaining NSTX's EPICS (system) will ...

1999-12-17

372

New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel  

Energy Technology Data Exchange (ETDEWEB)

A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.

1997-12-01

373

The cybernetics of viability: an overview  

British Library Electronic Table of Contents (United Kingdom)

A three-level approach to viability is developed, considering (1) living systems, (2) a niche, understood as the area within the reach of their actions, and (3) an environment. A systematic analysis of the interrelations between these levels shows that living systems emerge with matter/energy processing systems. These can add controller structures when producing excess energy. A three-sensor controller structure enables a living system to deal with unfavourable and scarce environments. Further evolution of these controller structures offers improved ways to act on niches. Maintaining niches in scarce environments can require technology or economy. So social systems emerge, which are understood as aggregates of living systems. Basic patterns of interactions within social systems ...

2011-01-01

374

Liquid level control system of fast reactor secondary cooling system  

International Nuclear Information System (INIS)

Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).

375

Embedded systems for vacuum control at PEFP  

International Nuclear Information System (INIS)

Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.

2005-05-26

376

Studies on a new kind of fuzzy power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the application of a new fuzzy inference method to the design of fuzzy power system stabilizer. Based on Truth-Value-Flow-Inference (TVFI), a fuzzy logic controlled power system stabilizer is proposed to enhance the stability of power system with weak or negative damping. The design of the proposed fuzzy power system stabilizer is presented. Numerical simulation results are presented and compared with two other kinds of fuzzy power system stabilizers. (author)

1998-12-31

377

Combined heuristic with fuzzy system to transmission system expansion planning  

Energy Technology Data Exchange (ETDEWEB)

A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)

2011-01-15

378

A predictive integrated voltage regulator and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

An integrated voltage regulator and power system stabilizer based on one step ahead prediction is presented. The fixed parameter predictive control scheme is shown capable of providing consistently good voltage response and contribution to system damping over a wide range of operating conditions and system configuration. This is in contrast to the case with conventional automatic voltage regulator and power system stabilizer where performance varies widely with the operating situation and can even cause system instability. (author)

1995-04-01

379

Stability and chaotification of vibration isolation floating raft systems with time-delayed feedback control  

Science.gov (United States)

This paper presents a systematic study on the stability of a two-dimensional vibration isolation floating raft system with a time-delayed feedback control. Based on the generalized Sturm criterion, the critical control gain for the delay-independent stability region and critical time delays for the stability switches are derived. The critical conditions can provide a theoretical guidance of chaotification design for line spectra reduction. Numerical simulations verify the correctness of the approach. Bifurcation analyses reveal that chaotification is more likely to occur in unstable region defined by these critical conditions, and the stiffness of the floating raft and mass ratio are the sensitive parameters to reduce critical control gain.

2011-09-01

380

Automatic control of the Wattenberg Gas Field, Colorado  

Energy Technology Data Exchange (ETDEWEB)

This paper discusses the successful implementation of automatic control in the Wattenberg Gas Field in northern Colorado. Also discussed is the use of solar powered Amocams equipment to affect continuous monitoring and control of these tight gas wells. The control system includes an algorithm which continuously adjusts the production cycling based on changes in the individual well's producing pressures and flow rates. This strategy has been successful in enhancing production and reducing the number of wells logged off due to excessive fluid buildup. The benefits derived from this system are enumerated and the impacts on field operations are discussed.

1982-09-01

381

Acceleration Control in Nonlinear Vibrating Systems based on Damped Least Squares  

CERN Document Server

A discrete time control algorithm using the damped least squares is introduced for acceleration and energy exchange controls in nonlinear vibrating systems. It is shown that the damping constant of least squares and sampling time step of the controller must be inversely related to insure that vanishing the time step has little effect on the results. The algorithm is illustrated on two linearly coupled Duffing oscillators near the 1:1 internal resonance. In particular, it is shown that varying the dissipation ratio of one of the two oscillators can significantly suppress the nonlinear beat phenomenon.

2011-01-01

382

Correlation between tensile property and micro-hardness in reduced activation ferritic/martensitic steel irradiated at 573 K  

International Nuclear Information System (INIS)

Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials used in this study were F82H IEA heat and F82H heat treatment variants. Neutron ...

2007-12-10

383

Viscoelastic locally resonant double negative metamaterials with controllable effective density and elasticity  

British Library Electronic Table of Contents (United Kingdom)

A metamaterial that is composed of solid viscoelastic elements with controllable properties is proposed in this Letter. This enables an adaptable and general acoustic metamaterial to be practically realised. An array of masses with a single elastic connection to a supporting viscoelastic structure, such as one that is dynamically equivalent to an array of Helmholtz resonators, only provides a system with negative effective mass. A local active control scheme applied to each of these masses can emulate additional elastic connections to the supporting structure. An array of masses with a suitable local control scheme can provide both the negative effective stiffness and mass required for negative refraction. The tuneable feedback control parameters determine the characteristics of the region...

2010-01-01

384

Neural integrated control for a free-floating space robot with suddenly changing parameters  

British Library Electronic Table of Contents (United Kingdom)

Because the state of a free-floating space robot model is uncertain and sudden changes in the model parameters might undermine the stability of the system, this paper proposes a control strategy based on a variable structure neural integrated controller. This scheme does not need a precise space robot model, making use of the radial basis function neural network ability approach to learn about an uncertain model. The network weights are adjusted online in real-time. During the early period of the control phase and parameter changes, the variable structure controller compensates for the uncertain model which the neural network could not learn well. It also creates global asymptotic stability for the whole closed-loop system. Simulation results show that the controller can handle bad changea...

2011-01-01

385

Linearization of Valve Flow Characteristics for Steam Turbine Control  

Energy Technology Data Exchange (ETDEWEB)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.

2009-05-15

386

Linearization of Valve Flow Characteristics for Steam Turbine Control  

International Nuclear Information System (INIS)

The control valve for a large steam turbine must be operated linearly to be run by an automatic control system in a power plant. It is, however, found that the flow increase is much greater for a given valve position change near the closed end of travel than it is near the open end. Accordingly, the desired linearization will be achieved if the valve is opened less near the closed end of travel and greater near the open end. The previous way for linearization was to utilize the cams, which is called the mechanical hydraulic control (MHC). The MHC was afterward improved by producing the nonlinear electric compensation to the nonlinear system of control valves, viz. the electro hydraulic control (EHC). This paper addresses the principle of linearization.

2009-05-01

387

System and method for controlling erosion of a shoreline  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a system for controlling erosion of the slope between the waterline of a shoreline. The system comprises an elongated conduit; means to pivotably secure the conduit to the shoreline approximately at the waterline; a plurality of individual armor bags attached to the conduit; and means for filling all of the individual armor bags with a grout material whereby the armor bags when filled with the grout material will be positioned as a unit onto the slope below the waterline.

1987-09-15

388

SOLERAS - Solar Controlled Environment Agriculture Project. Final report, Volume 4. Saudi Engineering Solar Energy Applications System Design Study  

Energy Technology Data Exchange (ETDEWEB)

Literature summarizing a study on the Saudi Arabian solar controlled environment agriculture system is presented. Specifications and performance requirements for the system components are revealed. Detailed performance and cost analyses are used to determine the optimum design. A preliminary design of an engineering field test is included. Some weather data are provided for Riyadh, Saudi Arabia. (BCS)

1985-01-01

389

Proceedings, international symposium on mine mechanization and automation  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under the session headings: research in mechanical fragmentation; rock characterization, remote sensing and interface detection; monitoring, data transmission and communications; tunnel boring machines; minewide monitoring and expert systems for ground control; machine guidance; shaft and raise boring; automation of drilling equipment; machine automation and control; new developments in mechanical miners; materials handling; innovative mining systems; general minewide monitoring and expert systems; ground support; human factors; and extraterrestrial mining.

1991-01-01

390

Matching Vehicle Responses Using the Model-Following Control Method  

Science.gov (United States)

The Variable Dynamic Testbed Vehicle (VDTV) is presently being developed by the National Highway Traffic Safety Administration (NHTSA). It is being designed to have a steer-by-wire front steering system and an independent rear steering system. These steering systems enable the VDTV to emulate the directional control characteristics of a broad range of passenger vehicles.

1997-01-01

391

Examination of scaling criteria for nuclear reactor thermal-hydraulic test facilities  

International Nuclear Information System (INIS)

Scaling criteria for a natural-circulation loop are examined. The present state of knowledge of scaling to obtain similarity during single- and two-phase flow conditions in a closed loop are reviewed, and an alternative development of two-phase similarity parameters is presented. The loop scaling criteria are the results of analyses in which flow from one component to another is considered. In this work, boundary conditions for the closed loop are developed to obtain scaling criteria for leak flow, injection flow, and heat loss to ambient. The leak scaling criteria are specialized for modeling approaches using prototypic fluid at prototypic or reduced pressures. The derived scaling parameters are examined for their application to two existing scaled test facilities: the Multi-Loop Integral System Test (MIST) facility at Babcock and Wilcox, and the UMCP 2 x 4 facility at the University of Maryland ...

1987-01-01

392

Chaos and bifurcation control of SSR in the IEEE second benchmark model  

International Nuclear Information System (INIS)

Linear and nonlinear state feedback controllers are proposed to control the bifurcation of a phenomenon in power system, this phenomenon of electro-mechanical interaction between the series resonant circuits and torsional mechanical frequencies of the turbine-generator sections, which known as subsynchronous resonance (SSR). The first system of the IEEE second benchmark model is considered. The dynamics of the two axes damper windings, automatic voltage regulator and power system stabilizer are included. The linear controller gives better initial disturbance response than that of the nonlinear, but in a small narrow region of compensation factors. The nonlinear controller not only can be easily implemented, but also it stabilizes the operating point for all values of the bifurcation parameter.

2004-07-01

393

An adaptive synchronous generator stabilizer design by generalized multivariable pole shifting (GMPS) technique  

Energy Technology Data Exchange (ETDEWEB)

A robust adaptive Power System Stabilizer algorithm using a Generalized Multivariable Pole Shifting (GMPS) technique is presented in this paper. The algorithm handles systems with equal or unequal numbers of inputs and outputs, therefore both shaft speed as well as the generator power are used to derive the stabilizing control. The technique also provides a simple scheme of on-line self-searching pole shifting factor to meet the excitation control limits. The application of the proposed stabilizer to a simulated generator excitation control under a wide range of operating and disturbance conditions demonstrates that the new control strategy is superior to conventional Power System Stabilizer (PSS) and the widely accepted Minimum Variance Self-Tuning Controller (MVSTC).

1992-08-01

394

Two- level fuzzy control of large-scale systems and Its application into Pss design  

International Nuclear Information System (INIS)

This paper propose a two-level suboptimal control using fuzzy predication to control large-scale systems. A class of large-scale linear systems composed of interconnected subsystems is investigated. The overall control problem that is posed as a minimization of overall objective function, which is considered to be of quadratic form, is reduced to some optimization problems of lower order (sub)systems. The control input of each subsystem is composed of two signals. The first represents the local control signal (first level) and the second is the predication signal (second level). In fact, the second signals is the prediction of other subsystems. It applies to each subsystem at every specified sample time (coordination sample times ). The fuzzy logic theory is used for interaction prediction, where the prediction single is ...

2003-01-01

395

Thermohydraulic study of a MTR fuel element aimed at the construction of an irradiation facility; Estudo termohidraulico de um elemento combustivel tipo MTR visando a construcao de um dispositivo de irradiacao  

Energy Technology Data Exchange (ETDEWEB)

A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)

1980-07-01

396

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

397

Coal-liquefaction-process research quarterly report, January 1 - March 31, 1982  

Science.gov (United States)

Objectives of the program are to understand the mechanisms of coal liquefaction, to determine the role of catalysts in the direct conversion of coal to liquids, to determine the mechanism of catalyst deactivation and to explore slurry phase catalyst systems. Specific projects include: short-contact time coal liquefaction, mineral matter effects and catalyst studies. During this period, work was performed on: (1) the stability, at reaction temperature, of a recycle solvent obtained from the Lummus Two Stage Liquefaction facility, (2) reactions of preasphaltenes and asphaltenes prepared under various reaction severities, (3) the evaluation of the catalyst level detector installed at the H-Coal facility, (4) the characterization of oil soluble metal compounds with respect to hydrogenation activity, and (5) characterization, deactivation and regeneration of catalysts obtained from both the H-Coal and Lummus ...

1982-10-01

398

1 The German National Analysis Facility as a tool for ATLAS analyses  

CERN Document Server

In 2008 the German National Analysis Facility (NAF) at DESY was established. It is attached to and builds on top of DESY Grid infrastructure. The facility is designed to provide the best possible analysis infrastructure for high energy particle physics of the ATLAS, CMS, LHCb and ILC experiments. The Grid and local infrastructure of the NAF is reviewed with a focus on the ATLAS part. Both parts include large scale storage and a batch system. Emphasis is put on ATLAS specific customisation and utilisation of the NAF. This refers not only to the NAF components but also to the di erent components of the ATLAS analysis framework. Experience from operating and supporting ATLAS users on the NAF is presented in this paper. The ATLAS usage of the di erent components are shown including some typical use cases of user analysis. Finally, the question is addressed, if the design of the NAF meets the ATLAS expectations for effcient data ...

2011-01-01

399

DYMAC communications system  

Energy Technology Data Exchange (ETDEWEB)

The DYMAC Communications System is part of a nuclear safeguards system called DYMAC - short for DYnamic Materials ACcountability - that gathers accountability information at the Los Alamos Scientific Laboratory (LASL) Plutonium Processing Facility. The communications system handles transmissions between data-entry terminals and nondestructive assay (NDA) instruments located in the facility, and a computer located in an adjacent building. System design emphasizes reliability rather than high speed to ensure the integrity of data transmissions. This manual is directed toward the person responsible for maintaining the DYMAC Communication System. It describes the components that make up the communications network, explains how they operate, and gives detailed information about all of the connections. Many of the system ...

1980-01-01

400

Radiation hazard control report  

Energy Technology Data Exchange (ETDEWEB)

The radiation control carried out in Atomic Energy Research Institute, Kinki University, for the reactor installation and the tracer/accelerator facilities from April, 1981, to March, 1982, is described. The reactor was operated for total 1057.1 hours at the maximum heat output of 1 W. The persons subject to radiation protection as of April, 1981, were 126 persons in all, including 23 in radiation work and 11 in X-ray work, etc. The contents of this report are as follows: personnel monitoring (health examination, the control of individual exposure dose); laboratory monitoring (the measurement of area dose rate, radioactive concentration in air and water, and surface contamination density); field monitoring (environmental ..gamma..-ray dose rate, radioactive concentration in environmental samples); the use of unsealed radioisotopes, etc.

1982-12-01

401

Assessment and control of fetal exposure  

Energy Technology Data Exchange (ETDEWEB)

The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, ...

1991-10-01

402

A shallow subsurface controlled release facility in Bozeman, Montana, USA, for testing near surface CO2 detection techniques and transport models  

Energy Technology Data Exchange (ETDEWEB)

A controlled field pilot has been developed in Bozeman, Montana, USA, to study near surface CO2 transport and detection technologies. A slotted horizontal well divided into six zones was installed in the shallow subsurface. The scale and CO2 release rates were chosen to be relevant to developing monitoring strategies for geological carbon storage. The field site was characterized before injection, and CO2 transport and concentrations in saturated soil and the vadose zone were modeled. Controlled releases of CO2 from the horizontal well were performed in the summers of 2007 and 2008, and collaborators from six national labs, three universities, and the U.S. Geological Survey investigated movement of CO2 through the soil, water, plants, and air with a wide range of near surface detection techniques. An overview of these results will be presented.

2009-10-20

403

The Wilsonville Advanced Coal Liquefaction Research and Development Facility, Wilsonville, Alabama  

Energy Technology Data Exchange (ETDEWEB)

This report presents the operating results for Run 255 at the Advanced Coal Liquefaction Research and Development Facility in Wilsonville, Alabama. This run operated in the Close Coupled Integrated Two-Stage Liquefaction mode (CC-ITSL) using Martin Lake Texas lignite. The purpose of this run was to demonstrate unit and system operability with Martin Lake lignite. Run 255 began on 20 March 1988 and continued through 9 June 1988. During this period, 204.4 MF tons of Martin Lake Texas lignite were fed in 1865.5 hours of operation. 70 figs., 21 tabs.

1991-05-01

404

Testing of the 1-MWth bench-model cavity-receiver steam generator  

Science.gov (United States)

A schematic of the Bench cavity receiver system is given, and the primary objectives, schedule and research plan for each of four tests are discussed. The tests are: (1) cold flow testing to functionally check all valves and their response using high pressure nitrogen gas; (2) a hot checkout to simulate both steady state and transient flux inputs to the receiver which are expected at the French facility; (3) basic performance using solar energy at the French facility; and (4) ir radiant heat testing. (LEW)

405

How Waste Management Can Be Influenced By Transport Packagings  

Science.gov (United States)

With major D&D projects ongoing or being planned, and also with the daily management of radwaste from nuclear facilities, the potential role of transport packagings has often been overlooked: here will one rely essentially on drums, there several local waste processing units are built, elsewhere decommissioned facilities are cut in small bits to fit into small containers by far less efficient. The present paper proposes to illustrate how integrating a transport system from the start may influence operational choices of waste management.

2002-02-28

406

Bechtel Hanford Inc. Network Security Plan for the EnvironmentalRestoration Contract  

Science.gov (United States)

'As part of the Computer Protection Plan, this Network Security Plan identifies the specific security measures used to protect Bechtel Hanford, Inc.'s (BHI's) enterprise network. The network consists of the communication infrastructure and information systems used by BHI to perform work related to the Environmental Restoration Contract (ERC) at the Hanford Site. It provides electronic communication between the ERC-leased facilities in Richland, Washington, and facilities located on the Hanford Site. Network gateways to other site and offsite networks provide electronic communication with the remainder of the Hanford community.'

1999-06-30

407

Adaptive power-system stabilizer based on turbine governor control  

Energy Technology Data Exchange (ETDEWEB)

A novel adaptive stabilizer, called an Adaptive Governor Power System Stabilizer (AGPSS), which operated on the governor turbine system, was described. There has been extensive research on adaptive excitation control of generators in power systems with the goal of achieving better dynamic performance. AGPSS tracks the frequency and damping of oscillations in a power system, and adjusts to ensure that there is always sufficient damping in the system. There is no interaction between stabilizers on different generating units, and each one acts independently, consuming oscillation energy locally. These stabilizers are easy to design and this facilitates their use in multimachine systems. Results obtained by nonlinear simulation of a single-machine and a three-machine power system were discussed, illustrating the ...

1994-12-31

408

Application of pumped storage plants in the control of the Slovak power system and the possibility of pumped storage plant Ipel exploitation towards the year 2010  

International Nuclear Information System (INIS)

The paper deals with the exploitation of the pumped storage plants for the control of the Slovak power system. For that purpose current utilization of pumped storage plants currently in operation was analyzed from the point of view of their part in the operation control of the Slovak power system. The aim of this analysis was to exploit knowledge gained so far for the future outlook up to the year 2010, including the evaluation of the need to construct pumped storage plant Ipel with a weekly storage cycle. (author).

1997-05-13

409

The Bevatron liquid nitrogen circulation system  

Science.gov (United States)

A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.

1987-03-01

410

Power system stabilizer design based on structured singular values  

Energy Technology Data Exchange (ETDEWEB)

In this paper, power system stabilizer design for multi-machine power systems is translated into an equivalent problem of decentralized controller design for Multi-Output Multi-Input (MIMO) control systems. Subject to a condition based on the structured singular values, each stabilizer can be designed independently. Within this general framework, the conventional stabilizer design methodology based on the concept of synchronous and damping torques is used to decide the design details of each stabilizer. The suggested design method is applied to a model of a practical 10 machine power system. (author)

1998-12-31

411

On the Generation of a Robust Residual for Closed-loopControl systems that Exhibit Sensor Faults  

DEFF Research Database (Denmark)

This paper presents a novel design methodology, based on shaping the system frequency response, for the generation of an appropriate residual signal that is sensitive to sensor faults in the presence of model uncertainty and exogenous unknown (unmeasured) disturbances. An integrated feedback controller design and robust frequency-based fault detection approach is proposed for Single-Input/Single-Output systems. The effciency of the proposed method is demonstrated on a Single Machine Innite Bus (SMIB) power system that achieves a coordinate power system stabilizer with satisfactory sensor fault detection capabilities.

2007-01-01

412

Fast Flux Test Facility reactor initial criticality predictions and measurements  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) was designed to test fast-reactor fuels and other nonfuel materials. In its 37 reactor cycles of operations, the FFTF reactor has performed very well and successfully completed all the irradiation testings with an operating efficiency factor as high as 98%. Since FFTF is an experimental reactor, its core loading changed from cycle to cycle. Depending on the number of test assemblies in the core and their location, the core loading can change significantly from an essentially homogeneous core loading to a relatively nonhomogeneous or even highly localized heterogeneous loading. Consequently, the core reload design and initial criticality analyses were required for each operating cycle. The zero power initial critical control rod bank height was predicted before each reactor startup. The initial critical prediction depends on the reactivity conditions at the end of the previous cycle, the temperature feedback ...

1992-06-07

413

Design of sediment-control measures for small areas in surface coal mining. Draft report  

Energy Technology Data Exchange (ETDEWEB)

The manual provides design information for four groups of sediment control structures and treatments which are suitable for use on small areas in surface coal mining. A detailed design procedure is given for each group which will estimate the total amount of settleable solids from a small area with a sediment control structure or treatment for a specific design storm. A procedure is also given for estimating the mean annual sediment yield from a small area. Information on design, installation, maintenance and cost is given for each sediment control measure. Methods for determining the maximum allowable area for each sediment control measure and for design of combined sediment control systems are presented. The design procedures contain numerous nomographs, graphs, and worksheets to facilitate the use of the design procedure. The sediment ...

1982-04-01

414

Design of sediment-control measures for small areas in surface coal mining  

Energy Technology Data Exchange (ETDEWEB)

The manual provides design information for four groups of sediment control structures and treatments which are suitable for use on small areas in surface coal mining. A detailed design procedure is given for each group which will estimate the total amount of settleable solids from a small area with a sediment control structure or treatment for a specific design storm. A procedure is also given for estimating the mean annual sediment yield from a small area. Information on design, installation, maintenance and cost is given for each sediment control measure. Methods for determining the maximum allowable area for each sediment control measure and for design of combined sediment control systems are presented. The design procedures contain numerous nomographs, graphs, and worksheets to facilitate the use of the design procedure. The sediment ...

1982-08-01

415

Reflux boiling heat removal in a scaled TMI-2 system test facility  

International Nuclear Information System (INIS)

An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.

1980-06-01

416

Odor purification by bio-function; Seibutsu kino niyoru akushujoka  

Energy Technology Data Exchange (ETDEWEB)

Odor purification process using bio-function, which is technologically called bio-deodorizing process, utilizes the function of microorganism to convert mal-odor substances to non-odor substances. It attracts attention because the operation cost of a facility is low due to non-use of chemicals and energy, and because it is environmentally friendly without the possibility of generating secondary pollution. It is being used in deodorizing at sewage treatment facilities, fertilizer plants, coating plants, and foundries in Japan, and is more widely used in Europe. The conventional deodorizing technology in Japan mostly focuses on processes of physical chemistry such as activated carbon treatment, chemical scrubbing, combustion, and masking, but bio-deodorizing process tends to replace the conventional processes. This paper explains (1) relation of mal-odor and microorganism, (2) bio-deodorizing system (solid phase ...

1999-11-30

417

Five years operating experience at the Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...

1987-04-01

418

Five years operating experience at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...

1987-09-13

419

Fabrication of core demonstration experiments for irradiation in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

A major initiative to develop and irradiate a long-life, mixed-oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the US Department of Energy. The FFTF, shown in Figures 1 and 2, is a 400 megawatt thermal, fast liquid metal reactor that tests liquid metal, space and fusion fuels and materials. The new fuel system, called the Core Demonstration Experiment (CDE) demonstrates the capability of achieving a three- to four-year life in a prototypic heterogeneous reactor environment under prototypic power and temperature conditions. This fuel system will greatly increase fuel performance and lifetime from the current standard FFTF driver fuel. New design features, fabrication development, CDE assembly fabrication, and irradiation status have been described.

1990-06-10

420

FFTF [Fast Flux Test Facility] reactor shutdown system reliability reevaluation  

International Nuclear Information System (INIS)

The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.

421

FFTF (Fast Flux Test Facility) reactor shutdown system reliability reevaluation  

Energy Technology Data Exchange (ETDEWEB)

The reliability analysis of the Fast Flux Test Facility reactor shutdown system was reevaluated. Failure information based on five years of plant operating experience was used to verify original reliability numbers or to establish new ones. Also, system modifications made subsequent to performance of the original analysis were incorporated into the reevaluation. Reliability calculations and sensitivity analyses were performed using a commercially available spreadsheet on a personal computer. The spreadsheet was configured so that future failures could be tracked and compared with expected failures. A number of recommendations resulted from the reevaluation including both increased and decreased surveillance intervals. All recommendations were based on meeting or exceeding existing reliability goals. Considerable cost savings will be incurred upon implementation of the recommendations.

1986-07-01

422

WATER SUPPLY ANALYSIS  

Energy Technology Data Exchange (ETDEWEB)

This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.

1996-02-06

423

Quantitative density measurements from a real-time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-01-01

424

Quantitative density measurements from a real-time neutron radiography system  

International Nuclear Information System (INIS)

An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.

1986-11-16

425

Nuclear fuel assembly identification using computer vision  

Science.gov (United States)

This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.

1985-11-01

426

Hydraulic braking system for loads subjected to impacts and vibrations  

International Nuclear Information System (INIS)

This invention concerns a hydraulic braking system for loads subjected to impacts and vibrations. These double acting telescopic type hydraulic braking systems possess significant drawbacks linked to possibly important hydraulic leaks due to (a) the use of many dynamic seals in such appliances and (b) the effects of the environment of the system on these seals, particularly when employed in nuclear power stations where the seals reach significant temperatures and are subjected to radiation. Under this invention a remedy is suggested to such drawbacks by integrating means to offset automatically the leaks and the accumulation of hydraulic fluid expansions, as well as facilities to show if such leaks have occurred.

427

Distributed-processing radiation management system for nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributed-processing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)

1999-06-01

428

Operating experience with a new accelerator control system based upon microprocessors  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and operating experience with a high performance control system tailored to the requirements of the SuperHILAC accelerator. A large number (20) of the latest 16-bit microcomputer boards are used in a parallel-distributed manner to get a high system bandwidth. Because of the high bandwidth, software costs and complexity are significantly reduced. The system by its very nature and design is easily upgraded and repaired. Dynamically assigned and labeled knobs, together with touch-panels, allow a flexible and efficient operator interface. An X-Y vector graphics system provides for display and labeling of real-time signals as well as general plotting functions. This control system allows attachment of a powerful auxiliary computer for scientific processing with access to accelerator parameters.

1981-03-01

429

Mold heating and cooling microprocessor conversion. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 ...

1995-07-01

430

Future directions in controlling the LAMPF-PSR Accelerator Complex at Los Alamos National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Four interrelated projects are underway whose purpose is to migrate the LAMPF-PSR Accelerator Complex control systems to a system with a common set of hardware and software components. Project goals address problems in performance, maintenance and growth potential. Front-end hardware, operator interface hardware and software, computer systems, network systems and data system software are being simultaneously upgraded as part of these efforts. The efforts are being coordinated to provide for a smooth and timely migration to a client-sever model-based data acquisition and control system. An increased use of the distributed intelligence at both the front-end and operator interface is a key element of the projects. 2 refs., 2 figs.

1991-01-01

431

ECOTRONIC - an electronic system for mixture formation  

Energy Technology Data Exchange (ETDEWEB)

Fhe ECOTRONIC system developed by Bosch und Pierburg System oHG is an electronic system for mixture formation for Otto-cycle engines complying with high operational requirements. Engineers incorporated electronic control of the quantity of mixture and mixture enrichment for supplementary functions into a reliable, low-cost system, which will also comply with future requirements concerning fuel consumption, emissions and driveability. The author of the present article reduces the carburetor down to its basic systems, explains how supplementary functions were converted from mechanical to either open or closed-loop electronic control, and describes the newly developed actuators, the control unit making use of digital technology, and the results achieved.

1984-02-01

432

Coordinated synthesis of multimachine power system stabilizer using an efficient decentralized modal control (DMC) algorithm  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new method for simultaneously selecting the power system stabilizer (PSS) parameters in multimachine power systems. Design of local output feedback power system stabilizer using local signal of the generator (e.g. speed or power) is formulated as a decentralized modal control (DMC) problem. Exact model reduction based on modal control theory is proposed to make the determination of PSS parameters highly efficient. Results obtained from the coordinated tuning of the parameters of three power system stabilizers equipped on a multimachine power system show that exact assignment of the eigenvalues associated with the poorly damped electromechanical modes can be achieved in a very efficient manner.

1986-01-01

433

Energy optimal synthesis of perodic motions in multibody systems; Energieoptimale Synthese periodischer Arbeitsbewegungen in Mehrkoerpersystemen  

Energy Technology Data Exchange (ETDEWEB)

In robotics inverse dynamics is a standard control concept for highly nonlinear multibody systems. It is shown, however, that inverse dynamics results in a high energy demand. Therefore, linear energy efficient state feedback controllers are designed in a way that a performance index representing the energy consumption is minimized. At the same time inequality constraints such as control error and limited input variables have to be met. For the control design an analytical solution by pole placement is presented as well as a numerical controller optimization. This control design includes small motions in the neighborhood of the operating point. Then, linear controllers are tested with respect to control error and energy consumption when undergoing large displacement motion. It is shown that linear ...

2006-07-01

434

iMAST Quarterly, Number 1, 1998  

Science.gov (United States)

... Airframe System Technoloqies Laser fabricated flooring Composite sandwich panels for noise control Spray formed HS aluminum alloys Protective ...

2011-05-14

435

Tree fruit IPM programs in the western United States: the challenge of enhancing biological control through intensive management  

British Library Electronic Table of Contents (United Kingdom)

The seminal work of Stern and his coauthors on integrated control has had a profound and long-lasting effect on the development of IPM programs in western orchard systems. Management systems based solely on pesticides have proven to be unstable, and the success of IPM systems in western orchards has been driven by conservation of natural enemies to control secondary pests, combined with pesticides and mating disruption to suppress the key lepidopteran pests. However, the legislatively mandated changes in pesticide use patterns prompted by the Food Quality Protection Act of 1996 have resulted in an increased instability of pest populations in orchards because of natural enemy destruction. The management system changes have made it necessary to focus efforts on enhancing biological control n...

2009-01-01

436

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

437

Read Code Quality Assurance  

UK PubMed Central (United Kingdom)

As controlled clinical vocabularies assume an increasing role in modern clinical information systems, so the issue of their quality demands greater attention. In order to meet the resulting stringent...Full Text Available

1998-07-01

438

MASTER - NASA Technical Reports Server  

Science.gov (United States)

Reactor Effluent Purification System. 7.4.3. Filter Reactor Outlet Gas (FROG). 7.5. Instrumentation and Controls for NSS Tests ...

439

Fractal dynamics in physiology: Alterations with disease and aging  

UK PubMed Central (United Kingdom)

According to classical concepts of physiologic control, healthy systems are self-regulated to reduce variability and maintain physiologic constancy. Contrary to the predictions of homeostasis, however,...Full Text Available

2002-02-19

440

Flight Research: Problems Encountered and What They Should ... - NASA  

Science.gov (United States)

flow separation occurred at the junction of the tip fin and the fuselage. ...... Systems, presented at the AGARD Guidance and Control and Flight Mechanics ...

441
442

Development of a UGV-Mounted Automated Refueling System ...  

Science.gov (United States)

... and Unmanned Undersea Vehicle (UUV) communities as well. ... utilizes the Multi-Robot Operator Control ... Extending Mobile Security Robots to Force ...

2011-05-13

443

Development of a Long-Range Gliding Underwater Vehicle ...  

Science.gov (United States)

... investigates the convergence of three main areas of UUV development; mission ... with an improved low-cost embedded-system robot controller, to ...

2008-09-01

444

Battle Management Command and Control (BMC2) Human ...  

Science.gov (United States)

... For communication systems that employ spatial audio technology to separate intercom and/or radio channels, configurations of the spatial ...

2005-06-01

445

Application of an inverse input/output mapped ANN as a power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

An artificial neural network (ANN), trained as an inverse of the controlled plant, to function as a power system stabilizer (PSS) is presented in this paper. In order to make the proposed ANN PSS work properly, it was trained over the full working range of the generating unit with a large variety of disturbances. Data used to train the ANN PSS consists of the control input and the synchronous machine response with an adaptive PSS (APSS) controlling the generator. During training, the ANN was required to memorize the reverse input/output mapping of the synchronous machine. After the training, the output of the synchronous machine was applied as the input of the ANN PSS and the output of the ANN PSS was used as the control signal. Simulation results show that the proposed ANN PSS can provide good damping of the power system over a wide operating range and ...

1994-09-01

446

A Theoretical Solid Oxide Fuel Cell Model for Systems Controls and Stability Design  

Science.gov (United States)

As the aviation industry moves toward higher efficiency electrical power generation, all electric

2008-01-01

447

A Theoretical Solid Oxide Fuel Cell Model for - The NASA Glenn ...  

Science.gov (United States)

May 31, 2011 ... A Theoretical Solid Oxide Fuel Cell Model for System Controls and Stability Design AUTHOR(S): Kopasakis, George; Brinson, Thomas; Credle, ...

448

A Magnetic Suspension and Excitation System for Spin Vibration ...  

Science.gov (United States)

High Cycle Fatigue Initiative Workshop -Active Vibration. Control/Engine. Health Monitoring Session December 10,. 1996. The presentation was titled "Active ...

449

/l//IIl/ Kennedy Space Center, Florida 12899  

Science.gov (United States)

inhi bi Led ethylene glycol-water solutions for Apol lo spacecraft en- vironmental control systems (I), the concentration of sodium sulfi te ...

450

Microprocessor system controlling gas-carburizing process  

Energy Technology Data Exchange (ETDEWEB)

This report introduces a microprocessor system composed of a Z-80 single-board computer controlling a gas-carburizing process. The system has 7 analogical input and output signals 24 switch signal-input and 12 switch signal-output signals, which are applicable for temperature, carbon potential, and mechanical-movement control of multipurpose sealed furnaces, or for mutiple-zone temperature, carbon potential, and mechanical-movement control of continuous gas carburizing furnaces; or for distributed control of pit-type carburizing furnaces. The setpoints of variables, such as treating time, temperature, carbon potential of carburizing period, carbon potential of diffusion period, depth of carburizing layer, P.I.D. etc., are entered by keyboard and stored into memories, and actual values are displayed by digital tubes. Furthermore, the fault of thermocouple, oxygen ...

1986-01-01

451

TPC magnet cryogenic system  

Energy Technology Data Exchange (ETDEWEB)

The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat ...

1980-03-01

452

Radisson community heating systems: technical and economic comparison of options. Final report  

Energy Technology Data Exchange (ETDEWEB)

The study reported was conducted to evaluate water source community heat pump systems for possible installation to serve a number of homes which are to be constructed in the northeast section of Radisson, New York. Although specific sites and facilities have been evaluated, it is the intent of this study to be site specific only to the extent of climatic conditions. In other words, the results of this study should apply to any area with similar climate.

1981-12-01

453

Overview of IAEA year 2000 activities in the Department of Safeguards  

International Nuclear Information System (INIS)

The IAEA Department of Safeguards established a project in 1996 for the year 2000 (Y2K) conversion activities. This project covered assessment, conversion and testing of the software applications, instrument evaluation software, embedded systems and Personal Computer (PC) hardware attached to various equipment. Significant progress has been made in converting the applications and instruments to be year 2000 compliant. At the same time Member states have made an effort as well in converting the systems used jointly at the facilities

1999-02-01

454

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

455

Corrosion of Cu-W condensates in tap water  

International Nuclear Information System (INIS)

Corrosion resistance of Cu-W system condensates in tap water was studies. It is shown that with an increase in W concentration in the condensates of the Cu-W system their corrosion in tap water enhances. In the material designated for power supply facilities the optimal tungsten content is up to 6%. Owing to formation of oxide film on the surface of the samples corrosion is stabilitized 40 h after the test start.

456

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This ...

2009-07-01

457

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility ...

2009-06-07

458

Electromagnetic levitation system: an experiment approach  

International Nuclear Information System (INIS)

In this paper, we propose a simple method for controlling an electromagnetic levitation (Mag lev) system. The model of the Mag lev system under consideration in this paper is third order, inherently nonlinear and unstable. For designing a controller to obtain a good disturbance rejection and being insensitive to parameter variations, we use an inner-loop and an outer-loop configuration. The configuration is the key to solve this problem. By using a nonlinear state transformation in the feedback path, a cascaded PI controller and a redefined input in the inner loop, we obtain a linear second order system. Furthermore, to achieve a stable system with a good disturbance rejection, we design a Pid controller cascaded with the inner loop system in the negative unity feedback configuration in the outer ...

1999-05-17

459

Long-term storage facility for reactor compartments in Sayda Bay - German support for utilization of nuclear submarines in Russia  

Science.gov (United States)

The German-Russian project that is part of the G8 initiative on Global Partnership Against the Spread of Weapons and Materials of Mass Destruction focuses on the speedy construction of a land-based interim storage facility for nuclear submarine reactor compartments at Sayda Bay near Murmansk. This project includes the required infrastructure facilities for long-term storage of about 150 reactor compartments for a period of about 70 years. The interim storage facility is a precondition for effective activities of decommissioning and dismantlement of almost all nuclear-powered submarines of the Russian Northern Fleet. The project also includes the establishment of a computer-assisted waste monitoring system. In addition, the project involves clearing Sayda Bay of other shipwrecks of the Russian navy. On the German side the project is carried out by the Energiewerke Nord GmbH (EWN) on behalf of the Federal ...

2007-07-01

460

MANAGEMENT PRE-START REVIEW FINAL REPORT FOR THE BIOSAFETY LEVEL 3 (BSL-3) FACILITY (B368) LAWRENCE LIVERMORE NATIONAL LABORATORY  

Energy Technology Data Exchange (ETDEWEB)

A Lawrence Livermore National Laboratory (LLNL) Management Pre-Start Review (MPR) Team was formed to independently verify the operational readiness of Building 368 (B368) Biosafety Level III (BSL-3) Facility to conduct research with biological pathogens and toxins including those considered Select Agents. Review objectives and criteria were developed from the DOE/NNSA and LLNL requirements. These were provided in the Implementation Plan for the Biosafety Level III (BSL-3) Facility Management Pre-Start Review (BSL-3 MPR) at Lawrence Livermore National Laboratory that was reviewed and approved by DOE/NNSA-LSO. The formal part of the LLNL MPR for the BSL-3 Facility was begun in August of 2005 but work on the MPR was stopped in October of 2005 due to the need for LLNL to reassess organizational and operational controls and respond to Centers for Disease Control and Prevention inquiries ...

2006-07-25

461

High-accuracy gauge control technologies over the full length and full width of cold rolled strip; Reikan tandemumiru ni okeru zencho{center_dot}zenpuku hanko seigyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

At tandem cold rolling mills in Kawasaki Steel, by means of applying newly developed strip longitudinal (rolling) and transverse gauge control systems, high accuracy of thickness of within {+-}0.5 % has been achieved over the full length and full width of cold rolled strip, as gauge accuracy in a coil in longitudinal and transverse directions has become an extremely important quality control item in the manufacturing of cold rolled sheets due to the stricter quality requirements of customers, in recent years. The longitudinal gauge accuracy has been improved by the development of a high-response drive system for a mill mair motor, an all-stands gauge control system and a dynamic set-up control system. The transverse gauge accuracy has been improved by applying a one-side tapered work roll shifting method and the ...

1999-12-01

462

Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5  

Energy Technology Data Exchange (ETDEWEB)

Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE`s Office of Environment, Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from ...

1994-01-01

463

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. ...

1999-07-01

464

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. ...

1999-04-19

465

The role of natural circulation in the FFTF [Fast Flux Test Facility] passive safety tests  

International Nuclear Information System (INIS)

A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety.

1987-12-13

466

Current waste-management practices and operations at Oak Ridge National Laboratory, 1982  

Energy Technology Data Exchange (ETDEWEB)

The need for efficient management of industrial chemical wastes, especially those considered hazardous or radioactive, is receiving increased attention in the United States. During the past five years, several federal laws have addressed the establishment of stronger programs for the control of hazardous and residual wastes. At a facility such as Oak Ridge National Laboratory (ORNL), an efficient waste management program is an absolute necessity to ensure protection of human health and compliance with regulatory requirements addressing the treatment and disposal of hazardous, nonhazardous, and radioactive wastes. This report highlights the major regulatory requirements under which the Laboratory must operate and their impact on ORNL facilities. Individual waste streams, estimates of quantities of waste, and current waste management operations are discussed.

1982-09-01

467

Comparison of FFTF (Fast Flux Test Facility) feedback reactivities with SASSYS calculations in a loss-of-flow-without-scram event  

International Nuclear Information System (INIS)

The Cycle 8A static tests conducted in the Fast Flux Test Facility (FFTF) during 1986 have resulted in the separation of various feedback reactivity components. These feedback components, described by closed-form equations depending only on the reactor temperature field, can be regarded as database for the validation and/or calibration of feedback mechanistic models. The SASSYS safety analysis code contains the most developed feedback reactivity models and was selected for the comparison study between database and mechanistic calculations for the FFTF. Although detailed feedback models for control rod repositioning and core radial expansion/bowing exist, only the simple models were available in SASSYS at the time of this study. The results are described in this paper.

1988-05-01

468

Annual report of JMTR, 1994. April 1, 1994 - March 31, 1995  

Energy Technology Data Exchange (ETDEWEB)

In FY1994, JMTR was in operation during 4 operation cycles with low enriched Uranium(LEU,20%) fuel for irradiation study of nuclear fuels and materials and for radioisotope production. Irradiation studies were carried out using capsules, Oarai Gas Loop-1(OGL-1), Oarai Shroud Facility(OSF-1) and hydraulic rabbits irradiation facilities in support of LWR, FBR, HTTR and thermonuclear reactor. Irradiation studies on blanket materials were intensively carried out. Power ramping tests were carried out and the future program is under consideration. For R and D works, neutron spectrum evaluation technology, re-instrumentation technique for irradiation fuel rod, remote controlled SEM apparatus and examination technique with miniaturized specimens were successfully developed. (author).

1996-03-01

469

Proceedings of the international topical meeting on remote systems and robotics in hostile environments  

International Nuclear Information System (INIS)

This book contains the proceedings of the International Topical Meeting on Remote Systems and Robotics in Hostile Environments. It is organized under the following sessions: Worldwide Applications Overview; Operating Mobile Systems; Sensors and Control Systems; Space Applications; Reactor Operations and Surveillance; Remote Equipment for Hazardous Operations; Future Mobile System; Mining and Construction Operations; Special Applications; Hot Cell Applications; Processing; Reactor Operations and Maintenance; Decontamination and Waste Handling; Remote Handling Development and Demonstration.

470

Embedded computer systems for control applications in EBR-II  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this paper is to describe the embedded computer systems approach taken at Experimental Breeder Reactor II (EBR-II) for non-safety related systems. The hardware and software structures for typical embedded systems are presented The embedded systems development process is described. Three examples are given which illustrate typical embedded computer applications in EBR-II.

1993-01-01

471

An approach to software quality assurance for robotic inspection systems  

International Nuclear Information System (INIS)

Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.

1993-11-14

472

The year 2000 embedded systems problem to maintain the safety of nuclear installations  

International Nuclear Information System (INIS)

The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors ...

1999-02-01

473

Implementation of Accelerated Beam-Specific Matched-Filter-Based Optical Alignment  

Energy Technology Data Exchange (ETDEWEB)

Accurate automated alignment of laser beams in the National Ignition Facility (NIF) is essential for achieving extreme temperature and pressure required for inertial confinement fusion. The alignment achieved by the integrated control systems relies on algorithms processing video images to determine the position of the laser beam images in real-time. Alignment images that exhibit wide variations in beam quality require a matched-filter algorithm for position detection. One challenge in designing a matched-filter based algorithm is to construct a filter template that is resilient to variations in imaging conditions while guaranteeing accurate position determination. A second challenge is to process the image as fast as possible. This paper describes the development of a new analytical template that captures key recurring features present in the beam image to accurately estimate the beam position under good image quality ...

2009-01-29

474

Externally-fired combined cycle: An effective coal fueled technology for repowering and new generation  

Energy Technology Data Exchange (ETDEWEB)

The Externally-Fired Combined Cycle (EFCC) is an attractive emerging technology for powering high efficiency combined gas and steam turbine cycles with coal or other ash bearing fuels. In the EFCC, the heat input to a gas turbine is supplied indirectly through a ceramic air heater. The air heater, along with an atmospheric coal combustor and ancillary equipment, replaces the conventional gas turbine combustor. A steam generator located downstream from the ceramic air heater and steam turbine cycle, along with an exhaust cleanup system, completes the combined cycle. A key element of the EFCC Development Program, the 25 MMBtu/h heat-input Kennebunk Test Facility (KTF), has recently begun operation. The KTF has been operating with natural gas and will begin operating with coal in early 1995. The US Department of Energy selected an EFCC repowering of the Pennsylvania Electric Company`s Warren Station for funding under the Clean Coal Technology ...

1995-06-01

475

Electron-beam welding of valve bodies; Elektronenstrahlschweissen von Armaturengehaeusen  

Energy Technology Data Exchange (ETDEWEB)

In early March, 2000 a modern electron-beam welding facility for both series and one-off production of valves bodies (500 kg, up to 50 mm wall thickness) was commissioned at Josch Strahlschweisstechnik. Welding is performed under a fine vacuum. This permits not only the welding of components subject to acceptance inspection (HP0 approval), but also of special materials such as titanium, molybdenum, tungsten, Hastelloy and copper, and also their pairings. Products are developed and readied for production using modern 3D CAD software. A modern nine-axis control system makes it possible to produce sockets in pipe-on-pipe joints. (orig.) [German] Anfang Maerz 2000 wurde eine moderne Elektronenstrahlschweissanlage fuer die Herstellung von Armaturengehaeusen in Grossserien oder auch fuer Einzelfertigung (500 kg, bis 50 mm Wanddicke) bei der Josch Strahlschweisstechnik in Betrieb genommen. Die Schweissungen erfolgen im Feinvakuum. ...

2000-03-01

476

Assessment of the PIUS physics and thermal-hydraulic experimental data bases  

Energy Technology Data Exchange (ETDEWEB)

The PIUS reactor utilizes simplified, inherent, passive, or other innovative means to accomplish safety functions. Accordingly, the PIUS reactor is subject to the requirements of 10CFR52.47(b)(2)(i)(A). This regulation requires that the applicant adequately demonstrate the performance of each safety feature, interdependent effects among the safety features, and a sufficient data base on the safety features of the design to assess the analytical tools used for safety analysis. Los Alamos has assessed the quality and completeness of the existing and planned data bases used by Asea Brown Boveri to validate its safety analysis codes and other relevant data bases. Only a limited data base of separate effect and integral tests exist at present. This data base is not adequate to fulfill the requirements of 10CFR52.47(b)(2)(i)(A). Asea Brown Boveri has stated that it plans to conduct more separate effect and integral test programs. If appropriately designed and conducted, these test programs ...

1993-12-31

477

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation measurement capabilities ...

1995-11-01

478

Mercury flow experiments. 3. Simulation test plan under abnormal condition  

Energy Technology Data Exchange (ETDEWEB)

Japan Atomic Energy Research Institute (JAERI) and High Energy Accelerator Research Organization (KEK) are promoting construction plan of Material-Life Science Facility, which is consisted of Muon Science Facility and Neutron Scattering Facility, in order to open up the new science fields. The Neutron Scattering Facility will be utilized for advanced fields of Material and Life science using high intensity neutrons generated by the spallation reaction induced by injecting a 1 MW pulsed proton beam onto a mercury target. Design of the spallation mercury target system is in progress to obtain good neutron performance keeping high reliability and safety. The target material is mercury. As a result of the spallation reaction, large amount of radioactive spallation products are to be contained in the mercury. Therefore to establish the safety of the target system, ...

2002-02-01

479

Solar energy utilization and microcomputer control in the greenhouse builk curing and drying solar system  

Energy Technology Data Exchange (ETDEWEB)

Three agricultural applications in a specially designed greenhouse solar system functioning as a multi-purpose solar air collector for crop production and curing/drying processes are examined. An automated hydroponic crop production system is proposed for the greenhouse solar system. Design criteria of the proposed system and its utilization of solar energy for root-zone warming are presented and discussed. Based upon limited testing of the hydroponic system considered, hydroponic production of greenhouse crops is believed reasonable to complement the year-round use of the greenhouse solar system. The hardware/software design features of a microcomputer-based control system applied in the greenhouse solar barn are presented and discussed. On-line management and utilization of incident solar energy by the microcomputer ...

1987-01-01

480

Wartsila 32DF, the dual-fuel engine  

Energy Technology Data Exchange (ETDEWEB)

This paper gives details of the development of the Wartsila 32DF duel-fuel lean-burn engine that can burn liquid or gaseous fuels, and reports on the installation of four of the engines in Turkey. The combustion process, and the design of the gas admission, pilot fuel, cylinder control, air-fuel control, and engine control and monitoring systems are described. The advantages of the engine are discussed.

1999-06-01

481

Power fluidics and the environment  

International Nuclear Information System (INIS)

This paper reviews power fluidics technology in the nuclear industry giving emphasis also on its potential uses in chemical plants and in flood and irrigation control. This is a technology of controlling process fluids by purely hydrodynamic methods, which should increase system reliability by eliminating valves, pumps and other fluid control devices that are often causes of failure. This review indicates that the hydrodynamics of fluidic components are not satisfactorily understood at present and may be more complex than similar theory in electronics.

482

On-line replacement of a particle accelerator control computer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the conversion from an existing production control computer, an SEL 840, to a DEC VAX 11/780. The plan is to add a layer of hardware to accomplish a smooth and gradual transition from the 840 to the VAX while leaving the underlying equipment unchanged. The architecture of the control system software is discussed for a large linear accelerator from the standpoint of its requirements and the particular design philosophy chosen.

1981-01-01

483

Instrumentation is the key to advanced mining techniques  

Energy Technology Data Exchange (ETDEWEB)

To achieve the high degree of management control and operational efficiency necessary for new undertakings, there will be a heavy dependence on schemes for the remote control and monitoring of all mine activities both on the surface and underground, plus the provision of information on operations, plant and equipment. This will all need to be supervised from a central control point on the colliery surface. A survey of recently introduced instrumentation systems makes it clear that British manufacturers already have made major advances in the field of automation, and new equipment constantly comes on to the market.

1980-04-01

484

INTEGRATED AIR POLLUTION CONTROL FOR COAL-FIRED UTILITY BOILERS: A COMPUTER MODEL APPROACH FOR DESIGN AND COST-ESTIMATING  

Science.gov (United States)

The paper describes the Integrated Air Pollution Control System (IAPCS), a computerized program that can be used to estimate the cost and performance of pre-combustion, in situ, and post-combustion air pollution control configurations in pulverized-coal-fired utility boilers of 1...

485

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

486

Optimal pole shifting controller for interconnected power system  

Energy Technology Data Exchange (ETDEWEB)

Research highlights: {yields} Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. {yields} Power system stabilizer was designed based on optimal pole shifting controller. {yields} The system performances was tested through load disturbances at different operating conditions. {yields} The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. {yields} The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary ...

2011-05-15

487

Optimal pole shifting controller for interconnected power system  

International Nuclear Information System (INIS)

Research highlights: ? Mathematical model represents a power system which consists of synchronous machine connected to infinite bus through transmission line. ? Power system stabilizer was designed based on optimal pole shifting controller. ? The system performances was tested through load disturbances at different operating conditions. ? The system performance with the proposed optimal pole shifting controller is compared with the conventional pole placement controller. ? The digital simulation results indicated that the proposed controller has a superior performance. -- Abstract: Power system stabilizer based on optimal pole shifting is proposed. An approach for shifting the real parts of the open-loop poles to any desired positions while preserving the imaginary parts is presented. In each step of ...

2011-05-01

488

Construction of the DIVA(direct vessel injection visualization and analysis test facility) for the LBLOCA of KNGR  

Energy Technology Data Exchange (ETDEWEB)

In this report, the descriptions of the DIVA test facility and those test matrixes are presented. The test sections simulate the downcomer annulus of DVI system with various scalling methodologies. The UPTF one has 1/7.5 scale and the APR-1400 test sections are reduced in 1/7 scale and 1/5 scale respectively. Also, the instrumentations, measuring methods are described. The major measuring parameters are ECC injection rate, air injection rate, bypass fraction, system pressure and so on. And finally, the operation procedure and experimental steps are introduced. From the DIVA tests, the multi-dimensional behaviors of two-phase flow in the downcomer during the reflood phase can be investigated using a transparent test facility. Also comparing the experimental data which are performed in various scale downcomer, it is expected that some criteria of scalling methodology proper to the DVI ...

2002-03-01

489

The Study for the Optimal Operation of D{sub 2}O Vapour Recovery System  

Energy Technology Data Exchange (ETDEWEB)

Digital control technology using micro-processor is widely used in Factory Automation area since 1980`s. However, the D{sub 2}O Vapour Recovery System in Wolsung 1 N.P.P is controlled by mechanical timer without considering the moisture condition in the Reactor Building and bed temperature, because it was designed using analog technology of 1960`s. This leads to the inefficient system operation and low D{sub 2}O recovery rate in addition to the high internal dose rate of operator. The goal of this phase II study is to develope a optimal automatic controller of D{sub 2}O vapour recovery system using PLC. We developed a control algorithm for Dual Tower Drier, a PLC control program, a operation change program and the monitoring system with a real-time simulator for system ...

1997-12-31

490

The Distributed Processing Approach to Providing a Combined Staffing and Word Processing System for Nursing Service  

UK PubMed Central (United Kingdom)

This Mini-Computer-Assisted Nursing Management System allows nursing to control staffing costs and more effectively relate staffing to patient care requirements. Nursing resources are prospectively...Full Text Available

1981-11-04

491

Ravenscraig coke ovens 1988 and onwards  

Energy Technology Data Exchange (ETDEWEB)

The coking plant is described with some details of coal supplies and coke quality. Engineering improvements to the by-product system and coke oven machines, major repair of two batteries, installation of a PLC-based monitoring and control system, and training of personnel are dealt with at greater length.

1989-01-01

492

Biosynthesis and Uptake of Siderophores Is Controlled by the PacC-Mediated Ambient-pH Regulatory System in Aspergillus nidulans  

UK PubMed Central (United Kingdom)

Biosynthesis and uptake of siderophores in Aspergillus nidulans are regulated not only by iron availability but also by ambient pH: expression of this high-affinity iron uptake system...Full Text Available

2004-04-01