Robotics for the production of several short-lived positron-emitting radiopharmaceuticals
International Nuclear Information System (INIS)
We have recently shown the applicability of robotics to the synthesis of a positron-emitting radiopharmaceutical, namely 16#alpha#[F-18]fluoroestradiol-17#beta#, a breast tumor imaging agent. We now report the application of the robot to the synthesis of two additional radiopharmaceuticals, [F-18]spiroperiodol and [C-11]butanol. This achievement shows the power of a robot as a multifunctional automated device for the synthesis of several positron-emitting radiopharmaceuticals in limited laboratory space. (author).
Radiopharmaceuticals for the imaging of functional abnormalities of the developing brain
International Nuclear Information System (INIS)
The measurement of physiological parameters in man is possible with the help of positron emission tomography (PET) and radiopharmaceuticals labeled with short lived positron emitters as C 11, N 13, O 15 and F 18. With the use of this substances it is possible to make a tomographic map defining regional metabolic parameters in normal and diseased brain. This technique has therefore also be named 'in vivo autoradiography'. The possibility of applying C 11 or F 18 labeled deoxyglucose with PET for detecting regional and local changes in cerebral metabolic rate of glucose in brain development in children of 5 days to 1 year of age is discussed. Beyond this a relationship between cerebral metabolic rate of glucose, cerebral blood flow and cerebral metabolic rate of oxygen by use of this technique after inhalation of O 15 and C 11-labeled CO_2 is shown. Attention is ...
Volatilization of fluorides from solid uranium(IV)fluoride
International Nuclear Information System (INIS)
... deposition evaporation fission products fluorides iodine 134 laboratory
1971-02-01
The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer
The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer
1998-01-01
Strength and fluoride release characteristics of a calcium fluoride based dental nanocomposite
UK PubMed Central (United Kingdom)
Secondary caries and restoration fracture remain the two most common problems in restorative dentistry. Release of fluoride ions (F) could be a substantial benefit because F could enrich neighboring...Full Text Available
2008-11-01
British Library Electronic Table of Contents (United Kingdom)
Water?rock interaction is one of the prime factors affecting the fluoride contents of surface and groundwater. If fluoride concentration of drinking water has been neglected, excess fluoride can cause serious dental and medical problems on human health, which is well known at Golcuk-Isparta region. In the research area, Egirdir lake, Golcuk lake and surrounding springs have been utilized as drinking water sources. Golcuk lake water and surrounding groundwaters have high fluoride content (1.4?4.6?mg/l), which is above the WHO standards. Fluoride is predominantly supplied by dissolution of fluoride within the fluormicas of volcanics during the circulation of water. Fluoride concentrations of waters have shown variations for dry and rainy seasons depending on the degree of interaction between...
2008-01-01
Comparison of FDG Uptake with Pathological Parameters in the Well-differentiated Thyroid Cancer
International Nuclear Information System (INIS)
Differentiated thyroid cancer (DTC) has variable degree of F-18 FDG avidity. The purpose of this study was to evaluate the relationship between F-18 FDG uptake and pathological or immunohistochemical features of DTC. DTC patients who underwent both pre-operative F-18 FDG PET/CT scan and surgery were included in the study. Maximum standardized uptake values (SUVmax) of primary tumor were calculated. If the primary tumor showed no perceptibly increased F-18 FDG uptake, region of interest was drawn based on finding of CT portion of the PET/CT images. Pathological and immunohistochemical markers such as presence of lymph node (LN) metastasis and underlying thyroiditis, tumor size, Ki-67 labeling index, expressions of EGFR, COX-2, and Galectin-3 were evaluated. Total of 106 patients was included (102 papillary carcinomas, 4 ...
2009-02-01
Positron wave function in ReO_3 by the APW method
International Nuclear Information System (INIS)
The wavefunction of a positron in ReO is calculated using the augmented-plane-wave method. Due to the loosely-packed structure of ReO_3, the ground-state GAMMA_1 wavefunction exhibits a marked anisotropy particularly around the oxygen ions, and a large fraction of a positron is distributed in the interstitial region. Experimental results of the positron annihilation 2#gamma#-correlations and the positron annihilation rates in ReO_3 are discussed based on the positron wavefunction. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Introduction The objective of this study was to investigate the in-vitro fluoride release from a glass ionomer orthodontic bonding system (Fuji I, GC Corporation, Tokyo, Japan) over a 2-month period and the in-vivo enamel fluoride uptake after 6 months. Methods Ten metal brackets were bonded with either glass ionomer or composite resin (Transbond XT, 3M Unitek, Monrovia, Calif; Light Cure), which served as controls, to recently extracted molars. The bonded teeth, cut at the level of their roots, were stored in distilled water that was renewed after every fluoride measurement at 1, 3, 7, 30, and 60 days. The in-vitro fluoride release was measured by using a fluoride ion-selective electrode, connected to an ion analyzer. Fifteen pairs of premolars were bonded with metal brackets with either ...
2010-01-01
[F-18]FDG PET metabolic indices for the evluation of glioma
International Nuclear Information System (INIS)
[F-18]FDG PET brain imaging is an accurate predictor of primary brain tumor grading and prognosis. The purpose of this study was to evaluate simplified [F-18]FDG PET metabolic indices as indicators of proliferative activity of brain tumor cells. Twenty-five patients with glioma were studied with [F-18]FDG PET. From the tissue radioactivity ratios, following tumor metabolic indices were calculated: 1) the tumor-to-whole brain ratio (T/WB), 2) the ratio of tumor-to-contralateral gray matter at the level of centrum semiovale (T/GM), 3) the ratio of tumor-to-contralateral white matter at the level of centrum semiovale (T/WM), 4) the tumor-to-ipsilateral cerebella ratio (T/iCB) and 5) the tumor-to-contralateral cerebellar ratio (T/cCB). A standardized threshold method was used to define ROIs in the tumor areas having representative metabolic activites. Correlations ...
1997-05-16
British Library Electronic Table of Contents (United Kingdom)
Levin KA, Jones CM, Wight C, Valentine C, Topping GVA, Naysmith R. Fluoride rinsing and dental health inequalities in 11-year-old children: an evaluation of a supervised school-based fluoride rinsing programme in Edinburgh. Community Dent Oral Epidemiol 2009; 37: 19-26. Copyright 2009 The Authors. Journal compilation Copyright 2009 John Wiley &Sons A/S Abstract - Objectives: Previous studies have shown that fluoride mouthrinsing programmes are effective in reducing caries among children and adolescents. National surveys of child dental health in the UK confirm that there is variation in oral health. In particular, children of low socioeconomic status in Scotland have a disproportionately high share of dental disease. This study aimed to evaluate an existing school-based fluoride mouthrinsi...
2009-01-01
{sup 18}F-labeled styrylpyridines as PET agents for amyloid plaque imaging
Energy Technology Data Exchange (ETDEWEB)
Positron emission tomography (PET) imaging of {beta}-amyloid (A{beta}) plaques in the brain is a potentially valuable tool for studying the pathophysiology of Alzheimer's disease (AD). It may also be applicable for measuring the effectiveness of therapeutic drugs aimed at lowering A{beta} plaques in the brain. We have successfully reported a series of {sup 18}F-labeled fluoropegylated stilbenes for PET imaging studies. Encouraging results clearly demonstrated the usefulness of {sup 18}F-labeled stilbenes as potential A{beta} plaque-imaging agents. In the present study, we applied a similar approach to a styrylpyridine backbone structure. Among all derivatives examined (E)-2-(2-(2-(2-fluoroethoxy)ethoxy)ethoxy)-5-(4-dimethylaminostyryl) -pyridine (2) displayed high binding affinity in postmortem AD brain homogenates (K {sub i}=2.5{+-}0.4 nM, with [{sup 125}I]IMPY as radioligand). No-carrier-added [{sup 18}F]2 was successfully prepared by [{sup ...
2007-01-15
Process and apparatus for chemically removing ash from coal
Finely divided ash-containing coal is immersed in an aqueous solution of hydrochloric acid or citric acid, and acidic ammonium fluoride to cause the ash to react with the acid and the acidic ammonium fluoride, and the deashed coal is thereafter separated from the solution.
1984-01-03
Fluoride ion promoted deprotection and transesterification in nucleotide triesters.
UK PubMed Central (United Kingdom)
Tetrabutylammonium fluoride will remove phenyl, trichloroethyl and cyanoethyl groups from nucleotides. In addition to the desired nucleotide products other results including chain cleavage, phosphofluoridates...Full Text Available
1979-10-10
UK PubMed Central (United Kingdom)
Alkyl halides react rapidly with purines and pyrimidines in the presence of fluoride ion. Alkylation of thymidine leads to novel dimeric nucleoside derivatives bridged through N3. Alkylation of thymidine...Full Text Available
1979-04-01
Corrosion Behavior of Titanium Grade 7 in Fluoride-Containing NaCl Brines.
The effects of fluoride on the corrosion behavior of Titanium Grade 7 (0.12-0.25% Pd) have been investigated. Up to 0.1 mol/L fluoride was added to the NaCl brines at 95oC, and three pH values of 4, 8, and 11 were selected for studying pH dependence of fl...
2004-01-01
Calcium fluoride window mounting
International Nuclear Information System (INIS)
A technique has been developed for joining a large calcium fluoride crystal to a stainless-steel flange by means of a silver transition ring. The process involves both vacuum brazing using a copper-silver alloy and air brazing using silver chloride. This paper describes the procedure used in fabricating a high-vacuum leak-tight calcium fluoride window assembly.
Energy Technology Data Exchange (ETDEWEB)
The present article describes a novel synthesis route for nano-sized goethite ({alpha}-FeOOH) using hydrazine sulphate as an additive. The X-ray diffraction (XRD) peaks of synthesized powder matched well with those of {alpha}-FeOOH. Transmission electron microscopy (TEM) showed the particles of irregular shape in the range of 1-10 nm. Batch adsorption experiments for fluoride uptake were performed to study the influence of various experimental parameters such as contact time (10 min to 7 h), initial fluoride concentration (10-150 mg L{sup -1}), pH (2-11.6) and the presence of competing anions. The time data fitted well to pseudo-second-order kinetic model. The fluoride removal passed through broad maxima in pH ranges of 6-8. High adsorption capacity of 59 mg g{sup -1} goethite was obtained. The isothermic data fitted well to Freundlich model. The presence of other ions namely chloride and sulphate adversely affected ...
2010-02-15
International Nuclear Information System (INIS)
Paper estimates the corrosion resistance and studies the character of dissolving of silicon-bearing austenite stainless steels in strongly oxidizing media containing phosphate and fluoride admixtures. Corrosion behaviour of the studied steels is determined to depend essentially on the content of admixture or alloying silicon, as well as, on their phase composition in many respects determined by the thermal treatment condition. Refs. 22, figs. 1, tabs. 2.
International Nuclear Information System (INIS)
The annual production of phosphate rock, on the order of about 30-40 million tons yearly, represents several million pounds of uranium. The present invention provides a process of purifying uranium tetrafluoride hydrate to produce a uranium (VI) peroxide product meeting 'yellow cake' standards using a double precipitation procedure. A fluoride complexing agent is used in the precipitation.
1978-06-27
Catalysis over activated zeolites
A process is provided for conducting organic compound conversion over a catalyst composition comprising a supported crystalline zeolite having a high initial silica-to-alumina mole ratio, said supported zeolite being prepared by compositing said crystalline zeolite with alumina, reacting the composite with a particular hydrogen fluoride solution in a specified way, drying the hydrogen fluoride reacted composite, treating the dried composite by hydrolysis, ammonolysis and/or by contact with an ammonium salt solution, and calcining the resulting material.
1985-02-19
Annihilation of a positron in a vacancy in aluminum
International Nuclear Information System (INIS)
Results of an augmented-plane-wave calculation of the positron lifetime and the angular-correlation curves for aluminum, both in the vacancy-free crystal and in the crystal with a vacancy, are presented. The environment of the vacancy was simulated by a face-centered-cubic supercell with a volume 27 times that of the standard primitive unit cell of the Al lattice. The calculated positron-vacancy binding energy is 3.36 eV at room temperature. The temperature dependences of the trapping potential, the positron-vacancy binding energy, and the positron lifetime both in the Bloch state and in the vacancy-trapped state, associated only with the static thermal expansion of the lattice, have been calculated. It is found that the fractional increase in positron lifetime in the Bloch state is only approx.80% of the fractional increase in the volume of the lattice. The lifetime in the ...
Positron annihilation in high-T/sub c/ superconductors
International Nuclear Information System (INIS)
We report ab initio calculations of positron wave functions in the high-T/sub c/ superconductors YBa_2Cu_3O_7, Bi_2Sr_2CaCu_2O_8, and Tl_2Ba_2CaCu_2O_8 using the general potential linearized augmented plane-wave method. The calculated positron wave functions are fairly insensitive to whether or not electron-positron correlation is included in the calculation for YBa_2Cu_3O_7 and Tl_2Ba_2CaCu_2O_8, but the calculated positron density is quite sensitive to correlation in Bi_2Sr_2CaCu_2O_8. While the positron wave function samples primarily the chain region in YBa_2Cu_3O_7, the results indicate that positrons should be good probes of the Cu-O layer-derived electronic states near the Fermi energy in Tl_2Ba_2CaCu_2O_8 since a large overlap with these states is predicted.
PAMELA data and leptonically decaying dark matter
Recently PAMELA released their first results on the positron and antiproton ratios. Stimulated by the new data, we studied the cosmic ray propagation models and calculated the secondary positron and antiproton spectra. The low energy positron ratio can be consistent with data in the convection propagation model. Above $\\sim 10$ GeV PAMELA data shows a clear excess on the positron ratio. However, the secondary antiproton is roughly consistent with data. The positron excess may be a direct evidence of dark matter annihilation or decay. We compare the positron and anti-proton spectra with data by assuming dark matter annihilates or decays into different final states. The PAMELA data actually excludes quark pairs being the main final states, disfavors gauge boson final states. Only in the case of leptonic final states the positron and ...
2008-01-01
System Requirements Document for the Molten Salt Reactor Experiment
Energy Technology Data Exchange (ETDEWEB)
The purpose of the conversion process is to convert the {sup 233}U fluoride compounds that are being extracted from the Molten Salt Reactor Experiment (MSRE) equipment to a stable oxide for long-term storage at Bldg. 3019.
2000-04-01
Paramagnetic susceptibility of nonstoichiometric fluorides with the fluorite-type structure
Energy Technology Data Exchange (ETDEWEB)
Magnetic properties of single crystals of nonstoichiometric fluorides M[sub 1-x]R[sub x]F[sub 2+x] (M = Ca, Sr, Ba; R = Ce, Pr, Nd, Gd, Ho, Er, Tm, Yb; with 0.05 [le] x [le] 0.28) with the fluorite-type structure have been studied for the first time. The magnetic susceptibility was measured using a Faraday balance in the 15-300 K temperature range. The samples are paramagnetic following the Curie-Weiss law. The values of paramagnetic Curie temperatures and effective magnetic moments of rare-earth ions have been found. Deviations of the temperature dependence of magnetic susceptibility from the Curie-Weiss law are observed for some nonstoichiometric fluorides at temperatures ranging from 60 to 85 K. Possible reaons for these deviations are discussed. Measurements of magnetic susceptibility provide an effective technique for a rapid and accurate determination of the concentration of rare-earth ions in nonstoichiometric ...
1993-01-01
Optical and mechanical properties of thermally evaporated fluoride thin films
Energy Technology Data Exchange (ETDEWEB)
As a result of health and safety issues surrounding the use of radioactive materials on coated optical components, there has been renewed interest in coating materials whose optical and mechanical properties approach those offered by their radioactive counterparts. Due to the radioactive nature of ThF{sub 4} and its widespread use in optical coatings, the coating industry is examining other low index and non-radioactive fluorides as possible alternatives. In this paper, the authors present the results of an experimental study on the optical and mechanical properties of thermally evaporated ThF{sub 4}, DyF{sub 3}, CeF{sub 3}, LiF, HfF{sub 4}, IRX, and IRB thin films, where the materials were deposited at different substrate temperatures. The objective is to examine this series of fluorides under comparable deposition conditions and with respect to such material properties as: n and k, film stress, and environmental stability. The optical ...
1998-06-08
UK PubMed Central (United Kingdom)
Methyl fluoride is frequently used to specifically inhibit acetoclastic methanogenesis, thus allowing determination of the relative contribution of acetate versus H2/CO2 to total...Full Text Available
2006-01-01
Bone scintigraphy in fluoride treated osteoporosis
Energy Technology Data Exchange (ETDEWEB)
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic ...
1985-05-01
International Nuclear Information System (INIS)
An earlier representation of the radial distribution of dose about the path of a heavy ion in liquid water is modified and extended to include silicon, lithium fluoride, and sodium iodide. 6 refs., 5 figs., 1 tab.
1989-09-01
Catalysis over activated high silica zeolites
A process is provided for conducting organic compound conversion over a catalyst composition comprising a specially treated crystalline zeolite having a high initial silica-to-alumina mole ratio, said zeolite having been synthesized from a reaction mixture comprising a diamine as a cation source. The treatment of the zeolite material comprises the sequential steps of reacting the zeolite with a dilute hydrogen fluoride solution, contacting the hydrogen fluoride solution reacted material with aluminum chloride vapor, and then treating the aluminum chloride contacted material to convert it to hydrogen form.
1985-05-07
Spectra of positrons and electrons emitted in "8"8Y decay
International Nuclear Information System (INIS)
The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.
Positron-Electron Pair Creation Near Threshold
Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.
2009-01-28
Energy Technology Data Exchange (ETDEWEB)
It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
The transformation of Pd/Si to Pd{sub 2}Si/Si is investigated using depth-resolved positron annihilation, x-ray diffraction and Auger electron spectroscopy studies. The observed defect-sensitive positron S-parameter value of 1.022-1.054 indicates the existence of divacancies across the silicide/silicon interface and Si substrate region. Our experimental observation of vacancy defects is consistent with the model proposed for excess vacancy generation across the interface consequent to Si diffusion. (letter to the editor)
2003-11-26
Influence of absorbed hydrogen on the positron lifetime spectra in Pd, Pd-Ag, Pd-Cu
International Nuclear Information System (INIS)
(1 Oct 1979). German Democratic Republic Alekseeva, OK Onishchuk, VA
1979-10-01
International Nuclear Information System (INIS)
A theoretical study of electron and positron band structures of zinc-blende AlN and InN and their alloy Al_0_._5In_0_._5N is presented using the first-principles full-potential linearized augmented plane-wave method. Equilibrium lattices constants are determined from the total-energy minimization method. The results are compared with previous calculations and with experimental measurement. Electron and positron charge densities are computed as function of position in the unit cell. Detailed plots of distributions are along the direction. The ionicity factors are calculated by means of three different approaches. The calculated results of the positron charge density reflect the high insight for the annihilation effect.
2005-06-01
Full potential all electron positron lifetime calculations: assessment of local enhancement factors
International Nuclear Information System (INIS)
We report the implementation of positron wave function and lifetime calculations in the all-electron full-potential linearized augmented plane wave method. Calculations of lifetimes for more than 30 materials with two different forms of the enhancement factor were done and compared to prior calculations and experiment. We find that reasonable agreement with experiment can be obtained within the local density approximation when all-electron full-potential calculations are done.
2008-04-01
International Nuclear Information System (INIS)
Using the linearized augmented-plane-wave (LAPW) -calculated electron and positron charge densities for YBa_2Cu_3O_7, the Brillouin-zone-reduced electron-positron momentum density is computed and the zone-reduced two-dimensional angular correlation of annihilation radiation (2D ACAR) spectrum is produced. The calculations show that the relative weights of the Fermi-surface discontinuities are substantially altered due to the positron preferentially sampling the Cu-O chain region. In addition, the reduced 2D ACAR spectrum contains large k-dependent wave-function effects. The theoretical zone-reduced 2D ACAR spectrum is compared to the several existing experimental spectra. It is concluded that, at present, positron-annihilation experiments do not provide consistent and clear evidence for the existence and shapes of Fermi surfaces in YBa_2Cu_3O_7.
New technetium-99m radiopharmaceuticals for brain imaging
International Nuclear Information System (INIS)
Radiopharmaceuticals for brain imaging are used for the detection of ischemia, tumours and dementia associatied with disorders of the blood flow in the brain. The current radiopharmaceuticals for brain imaging have various limitations: 2-(F-18)fluoro-2-deoxyglucose (F-18-FDG) has a very short half-life. The physical properties of di-#beta#-(piperidinoethyl)-(Se-75)selenide (Se-75-PIPSE) and di-#beta#-(morpholinoethyl)-(Se-75)-selenide (Se-75-MOSE) are not ideal. Thallium-201 diethyldithricarbamate (T1-201-DDC) has unfavourable nuclidic characteristics, limited availability, a long half-life and high cost. I-123 in N-isopropyl-p-iodoamphetamine (I-123-IMP) and N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propanediamine (I-123-HIPDM) are not freely available and are expensive. N-13-labelled ammonia has a very short half-life. Technetium-99m hexamethylpropyleneamineoxime (Tc-99m-HM-PAO) is ...
1988-08-01
British Library Electronic Table of Contents (United Kingdom)
Previously, we demonstrated that the lithium ion conduction in the perovskite-type manganese fluoride is attributed to counter cation-site vacancy mechanism. The divalent counter cation-doped KxBa(1-x)/2MnF3 was theoretically predicted as the lithium ion conductor in the perovskite-type manganese fluoride. In this study, we considered the oxygen doping for KxBa(1-x)/2MnF3 to realize the higher lithium ion conductivity. It is because lithium ion forms the stronger ionic bond with the doped oxygen anion. The hybrid-DFT calculations were performed to investigate the lithium ion conduction in the oxygen-doped KxBa(1-x)/2MnF3. The calculation results were discussed from the viewpoints of the potential energy curve, electron densities, and charge and spin densities. The effect of the lithium ion...
2009-01-01
Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium
International Nuclear Information System (INIS)
This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)
2011-02-01
Fluoride phosphate Li{sub 2}CoPO{sub 4}F as a high-voltage cathode in Li-ion batteries
Energy Technology Data Exchange (ETDEWEB)
As a new high-voltage cathode candidate for post 4V cathodes, ordered-olivine LiCoPO{sub 4} and fluoride phosphate, Li{sub 2}CoPO{sub 4}F were synthesized by solid-state reaction. Their structures were identified by neutron diffraction. The 5V discharge profiles were demonstrated using coin-type cells. Two important issues for commercial use, metal dissolution and oxygen release at elevated temperatures, were also tested with an atomic absorption spectrophotometer and differential scanning calorimeter, respectively. (author)
2005-08-26
ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation
International Nuclear Information System (INIS)
Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, ...
Radiopharmaceuticals labelled with positron emitting radionuclides
International Nuclear Information System (INIS)
A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.
1989-01-01
British Library Electronic Table of Contents (United Kingdom)
To investigate the variation in the fine structure of polyamide thin-film composite (TFC) membranes prepared via two different interfacial polymerization conditions (IP-I and IP-II), experiments on Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), water contact angle, and positron annihilation spectroscopy (PAS) coupled to a slow positron beam were conducted. Polyamide TFC membranes were prepared via the interfacial polymerization reaction between triethylenetetramine (TETA) and trimesoyl chloride (TMC) on the surface of a modified polyacrylonitrile (mPAN) membrane. Compared with the polyamide TFC membrane prepared via IP-I, the polyamide layer prepared via IP-II showed a shorter S plateau length (thinner thickness), a higher o-Ps intensity I3 value (higher free-volume con...
2010-01-01
Indirect Dark Matter Signals from EGRET and PAMELA compared
Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. The excess of diffuse Galactic Gamma Rays from EGRET shows all the features expected from DMA. The new precise measurements of the antiproton and positron fractions from PAMELA are compared with the EGRET excess. It is shown that the charged particles are strongly dependent on the propagation model used. The usual propagation models with isotropic propagation models are incompatible with the recently observed convection in our Galaxy. Convection leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space. It is shown that such anisotropic propagation models including convection prefer a contribution from DMA for the antiprotons, but the rise in the ...
2009-01-01
An identification method of positron production in laser beam interaction with targets
Energy Technology Data Exchange (ETDEWEB)
A simple electromagnetic transport system was constructed to identify very rare positrons produced in a powerful laser beam interaction with a target. Testing experiments were carried out with CO[sub 2]-laser (10[sup 12] W/cm[sup 2]) beam pulses ([tau] = 50 ns, f = 0.01 Hz) focused on the copper target, as well as with a 96 MeV alpha-particle beam irradiated carbon target. The results showed that the developed system could be effectively used for positron identification and evaluation of their energy by means of a time-of-flight method. The computerized system to deal with this problem, together with others related to the power laser beam interaction with targets, has been constructed. (orig.).
1992-10-01
International Nuclear Information System (INIS)
This talk summarizes recent progress in top quark physics studies for high energy linear electron-positron colliders as presented at the LCWS2000 Workshop at Fermilab. New results were presented for top pair production at threshold and in the continuum, as well as for top production at #gamma##gamma# colliders.
2001-07-09
Status of electron accelerators for linear colliders
Energy Technology Data Exchange (ETDEWEB)
The paper outlines the basic problems concerning creation of electron-positron linear colliders, as well as their present-day status. More details on the question can be found in the proceedings of recent workshops on linear colliders contained in the References. ((orig.)).
1995-02-01
Pulsars as the Sources of High Energy Cosmic Ray Positrons
Recent preliminary results from the PAMELA satellite indicate the presence of a large flux of positrons (relative to electrons) in the cosmic ray spectrum between approximately 10 and 50 GeV. As annihilating dark matter particles in many models are predicted to contribute to the cosmic ray positron spectrum in this energy range, a great deal of interest has resulted from this observation. Here, we consider pulsars (rapidly spinning, magnetized neutron stars) as an alternative source of this signal. After calculating the contribution to the cosmic ray positron and electron spectra from pulsars, we find that the spectrum observed by PAMELA could plausibly originate from such sources. In particular, a significant contribution is expected from the sum of all mature pulsars throughout the Milky Way, as well as from the most nearby mature pulsars (such as Geminga and B0656+14). The signal from nearby pulsars is expected to ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for cosmic ray ...
1995-09-01
UK PubMed Central (United Kingdom)
BackgroundIn vitro data suggest that changes in myocardial substrate metabolism may contribute to impaired myocardial function in diabetic cardiomyopathy (DCM)....Full Text Available
New radioisotope for lung ventilation studies: 19-neon
Energy Technology Data Exchange (ETDEWEB)
Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alpha particle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.
1980-10-01
High-energy Cosmic-Ray Positrons from Hidden-Gauge-Boson Dark Matter
We provide a scenario in which a hidden U(1) gauge boson constitutes dark matter of the Universe and decays into the standard-model particles through a kinetic mixing with an $U(1)_{B-L}$ gauge boson. Interestingly, our model can naturally account for the steep rise in the positron fraction recently reported by PAMELA. Moreover, we find that due to the charge assignment of $U(1)_{B-L}$, only a small amount of antiprotons are produced in the decay, which is also consistent with the PAMELA and other observational data.
2008-01-01
Emission of photons by electrons and positrons passing through a thin single crystal
Energy Technology Data Exchange (ETDEWEB)
We consider the radiation of particles (electrons and positrons) undergoing planar channeling in a single crystal of small thickness L. We show that for Lapprox...pi..b/theta/sub L/, where b is the lattice constant and theta/sub L/ is the Lindhard angle, in addition to the principal maxima of spontaneous radiation of channeled particles in the spectrum there are additional interference maxima, and the positions of all maxima of the radiation intensity depend on L. We discuss the dependence of the intensity of radiation at various frequencies on the crystal thickness.
1984-07-01
Electron momentum density measurements by means of positron annihilation and Compton spectroscopy
Energy Technology Data Exchange (ETDEWEB)
The electron momentum density is measured applying positron annihilation and Compton spectroscopy in order to get information about electron wave functions. Compton spectroscopic measurements of Pd-Ag and Cu-Zn alloy systems are carried out taking into account crystal structure, mixability, and order state. Three-dimensional momentum densities of silicon are determined in order to get better information about its electronic structure. The momentum density and the spin density of ferromagnetic nickel are investigated using angular correlation curves.
1982-01-01
Breast imaging with a dedicated PEM
International Nuclear Information System (INIS)
During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.
2004-07-11
A low-neutron background slow-positron source.
Energy Technology Data Exchange (ETDEWEB)
The addition of a thermionic rf gun [1] and a photocathode rf gun will allow the Advanced Photon Source (APS) linear accelerator (linac) [2] [3] to become a free-electron laser (FEL) driver [4]. As the FEL project progresses, the existing high-charge DC thermionic gun will no longer be critical to APS operation and could be used to generate high-energy or low-energy electrons to drive a slow-positron source. We investigated possibilities to create a useful low-energy source that could operate semi-independently and would have a low neutron background.
1998-10-09
British Library Electronic Table of Contents (United Kingdom)
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
2012-01-01
International Nuclear Information System (INIS)
Many hormones elicit effects on target cells by stimulating the enzyme phospholipase-C, which catalyzes the hydrolysis of phosphoinositides to the intracellular second messengers diacylglycerol and inositol phosphates. The present study examined the roles of FSH and guanine nucleotide-binding proteins (G-proteins) in regulating the hydrolysis of phosphoinositides in Sertoli cells. Sertoli cell cultures prepared from 16- to 18-day-old rats were incubated for 24 h with myo-[2-3H] inositol to label endogenous phospholipids. Treatment of cells from 0.5-20 min with preparations of ovine FSH ranging in potency from 1-60 times that of NIH FSH S1 did not affect accumulation of inositol phosphates. Levels of total [3H]inositol phosphates [[3H]inositol mono-, di-, and triphosphates (IP, IP2, and IP3)] in FSH-treated cultures was 75-120% the levels in control cultures over the various time intervals studied. Addition of testosterone and the combination of testosterone plus retinoic acid, agents ...
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
Effect of acidic fluoride solution on beta titanium alloy wire.
The interaction between acidic fluoride solution and beta titanium alloy was investigated to explore the changes that occur in beta titanium alloy by fluoride-containing acetic acid solutions. For this, alloy crystal structure, tensile strength, and elements released from the alloy wires were determined using four solutions (0.05%/pH 6, 0.05%/pH 4, 0.2%/pH 6, and 0.2%/pH 4) for 1 or 3 days. The immersed wire did not form any identifiable new crystal structure compared with the as-received wire. The tensile strength of the immersed wires was significantly reduced compared to the as-received wires in the test solutions if the period of immersion increased from as-received to 3 days. The fractured area of the immersed wire was reduced compared to the as-received one. The dimple pattern at the inner part and a cup-cone morphology at the outer part of the fractured wires were similar in both as-received and immersed wires. After a 3-day immersion, ...
2005-05-01
Energy Technology Data Exchange (ETDEWEB)
Positron annihilation experiments on Fe-Cu model dilute alloys of nuclear reactor pressure vessel (RPV) steels have been performed after neutron irradiation in JMTR. Nanovoids whose inner surfaces were covered by Cu atoms were clearly observed. The nanovoids transformed to ultrafine Cu precipitates by dissociating their vacancies after annealing at around 400degC. The nanovoids and the ultrafine Cu precipitates are strongly suggested to be responsible for irradiation-induced embrittlement of RPV steels. Effects of Ni, Mn and P addition on the nanovoid and Cu precipitate formations were also studied. The nanovoid formation was enhanced by Ni and P, but suppressed by Mn. The Cu precipitates after annealing around 400degC were almost free from these doping elements and hence were pure Cu in the chemical composition. Furthermore the Fermi surface of the 'embedded' Cu precipitates with a body centered cubic crystal structure was obtained from two ...
2003-03-01
A revised dosimetric model of the adult head and brain
Energy Technology Data Exchange (ETDEWEB)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-06-01
A revised dosimetric model of the adult head and brain
International Nuclear Information System (INIS)
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
1996-07-21
International Nuclear Information System (INIS)
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).
Energy Technology Data Exchange (ETDEWEB)
Amphiphilic block copolymers are synthesized by sulfonation of poly(styrene-b-methyl methacrylate) (PS-b-PMMA) using acetyl sulfate, and are blended with poly(vinylidene fluoride) (PVDF) to prepare a new proton exchange membrane, in which PMMA is miscible with PVDF. The morphology and the transport properties of the membranes are investigated as functions of the degree of sulfonation as well as the blend ratio. Notable transition of phase-separated morphology is observed as the PVDF content of the blend is increased. Both the proton conductivity and the ion-exchange capacity (IEC) of the membrane increase with increasing the degree of sulfonation of PS-b-PMMA, and they are also enhanced as the phase-separated domains of blend membrane are well-ordered. Unlike the Nafion membrane, the proton conductivity of the blend membrane increases up to 90 C, indicating the blend membrane shows better thermal stability than the Nafion membrane. (author)
2009-03-01
Oxidation kinetics of tetravalent uranium monofluoride complex by nitrous acid in HNO_3 medium
International Nuclear Information System (INIS)
The kinetics of oxidation of uranium (IV) monofluoride complex by nitrous acid in nitric acid solution have been studied. The experiments were carried out at constant ionic strength of 2M (HNO_3 and NaNO_3) and temperature in the range of 18-47 deg C. The rate of reaction was determined spectrophotometrically at a wavelength of 621 nm, at which the molar extinction coefficients of UF"3"+ and UF_2"2"+ are the same. It was shown that reaction orders for [HNO_2] and [HNO_3] are equal to 0.12 and 0.39, respectively. The values of activation parameters #DELTA#H"#not =# and #DELTA#S"#not =# are determined to be 83 kJ mol"-"1 and 75 J (mol.K)"-"1, respectively. The rate order of the reaction studied has a weak direct depedence on [H"+] in contrary to the strong and reverse dependence in the absence of fluoride ions. In conclusion, fluoride ions may strongly stabilize the U(IV) in nitric acid solutions. (author) 4 refs.; 3 figs.; 2 tabs.
1991-08-01
Large area electron beam pumped krypton fluoride laser amplifier
International Nuclear Information System (INIS)
Nike is a recently completed multi-kilojoule krypton fluoride (KrF) laser that has been built to study the physics of direct drive inertial confinement fusion. This paper describes in detail both the pulsed power and optical performance of the largest amplifier in the Nike laser, the 60 cm amplifier. This is a double pass, double sided, electron beam-pumped system that amplifies the laser beam from an input of 50 J to an output of up to 5 kJ. It has an optical aperture of 60 cm x 60 cm and a gain length of 200 cm. The two electron beams are 60 cm high x 200 cm wide, have a voltage of 640 kV, a current of 540 kA, and a flat top power pulse duration of 250 ns. A 2 kG magnetic field is used to guide the beams and prevent self-pinching. Each electron beam is produced by its own Marx/pulse forming line system. The amplifier has been fully integrated into the Nike system and is used on a daily basis for laser-target experiments. copyright 1997 American Institute of ...
Energy Technology Data Exchange (ETDEWEB)
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform infrared (FTIR) ...
2011-01-15
Aminated poly(vinyl chloride) (PVC) membranes were prepared that had a Nernstian response over a wide range of pH. The reaction between PVC and methyl-piperazine (MePIP) in dimethylformamide (DMF) was studied over a wide range of time and temperature, and in the presence of the catalyst, potassium fluoride (KF). Time, temperature, and KF increased the nitrogen (N) content of the resulting polymers, but sometimes at the expense of decreasing their specific viscosities (molecular weights). Activation energies of processes that occurred in different temperature ranges were estimated assuming an Arrhenius relationship. A Nernstian response occurred once the N content approached to about 0.3 w/w %, and was accelerated by the presence of KF at elevated temperatures. Increasing the N content above about 3% led to a loss of the Nernstian response either because of an increase in the double bond content and a subsequent decrease in polymer mobility, or because of a decrease ...
1998-03-15
Friction properties of WS{sub 2}/graphite fluoride thin films grown by pulsed laser deposition
Energy Technology Data Exchange (ETDEWEB)
Graphite fluoride (CF{sub x}) is investigated as an additive for WS{sub 2} thin films to reduce its sensitivity to moisture. The films are grown onto hardened 440C stainless steel disks by pulsed laser deposition using the 248 nm line from an excimer laser. Substrate temperature and additive concentration are varied to control film chemistry and crystal structure. The effect of relative humidity (i.e., < 1 to 85% RH) on friction is evaluated. Coatings grown at RT from targets with a low concentration of CF{sub x} exhibit ultra-low friction (ULF) behavior in dry air (i.e., {mu} {<=} 0.01), but friction increases with RH. Mechanisms for the ULF behavior are proposed which suggest that further reductions in friction are possible. Films grown at 300 C or with higher concentrations of CF{sub x} are relatively insensitive to humidity, but have more typical friction coefficients ({mu} {<=} 0.04) in dry air. (orig.)
1995-12-01
International Nuclear Information System (INIS)
A simple sample decomposition and laser fluorimetric determination of uranium at trace level is reported in certain refractory minerals, like ilmenite, rutile, zircon and monazite; environmental samples viz. soil and sediments; industrial waste materials, such as, coal fly ash and red mud. Ilmenite sample is decomposed by heating with ammonium fluoride. Rutile, zircon and monazite minerals are decomposed by fusion using a mixture of potassium bifluoride and sodium fluoride. Environmental and industrial waste materials are brought into solution by treating with a mixture of hydrofluoric and nitric acids. The laser induced fluorimetric determination of uranium is carried out directly in rutile, zircon and in monazite minerals and after separation in other samples. The determination limit was 1 #mu#g x g"-"1 for ilmenite, soil, sediment, coal fly ash and red mud samples, and it is 5 #mu#g x g"-"1 for rutile, zircon and monazite. The method is also ...
2005-10-01
Electrochemical corrosion behavior of AZ91D alloy in ethylene glycol
Energy Technology Data Exchange (ETDEWEB)
The effect of concentration on the corrosion behavior of Mg-based alloy AZ91D was investigated in ethylene glycol-water solutions using electrochemical techniques i.e. potentiodynamic polarization, electrochemical impedance measurements (EIS) and surface examination via scanning electron microscope (SEM) technique. This can provide a basis for developing new coolants for magnesium alloy engine blocks. Corrosion behavior of AZ91D alloy by coolant is important in the automotive industry. It was found that the corrosion rate of AZ91D alloy decreased with increasing concentration of ethylene glycol. For AZ91D alloy in chloride >0.05 M or fluoride <0.05 M containing 30% ethylene glycol solution, they are more corrosive than the blank (30% ethylene glycol-70% water). However, at concentrations <0.05 for chloride or >0.05 M for fluoride containing ethylene glycol solution, some inhibition effect has been observed. The ...
2009-11-01
Electrochemical corrosion behavior of AZ91D alloy in ethylene glycol
International Nuclear Information System (INIS)
The effect of concentration on the corrosion behavior of Mg-based alloy AZ91D was investigated in ethylene glycol-water solutions using electrochemical techniques i.e. potentiodynamic polarization, electrochemical impedance measurements (EIS) and surface examination via scanning electron microscope (SEM) technique. This can provide a basis for developing new coolants for magnesium alloy engine blocks. Corrosion behavior of AZ91D alloy by coolant is important in the automotive industry. It was found that the corrosion rate of AZ91D alloy decreased with increasing concentration of ethylene glycol. For AZ91D alloy in chloride >0.05 M or fluoride 0.05 M for fluoride containing ethylene glycol solution, some inhibition effect has been observed. The corrosion of AZ91D alloy in the blank can be effectively inhibited by addition of 0.05 mM paracetamol that reacts with AZ91D alloy and forms a protective film on the surface at this concentration as ...
2009-11-01
Energy Technology Data Exchange (ETDEWEB)
The methodology of the drip procedure of the Standard Test Method for Evaluating the Influence of Thermal Insulation on External Stress Corrosion Cracking Tendency of Austenitic Stainless Steel (ASTM C 692-95a) was used to research the effect of halogens and inhibitors on the external stress corrosion cracking (ESCC) of Type 304 stainless steel as it applies to the insulation industry. Simulated insulation extraction solutions were made with pure chemical reagents for the halogens and inhibitors. The results indicated that sodium silicate compounds that were higher in sodium were more effective for preventing chloride-induced ESCC in Type 304 austenitic stainless steel. Potassium silicate was not as effective as sodium silicate. Fluoride, bromide, and iodide may cause ESCC but they were much less active than chloride and could be effectively inhibited by sodium silicate compound. The addition of fluoride ions to the chloride/sodium silicate ...
1997-11-01
Energy Technology Data Exchange (ETDEWEB)
A method for determining the reactivity of subcritical systems of fissile material, using neutron-noise power spectral density measurements in conjunction with a /sup 252/Cf source, has been tested in experiments with an aqueous solution containing uranium fluoride (4.95 wt% /sup 235/U). The kappasub(eff)-values obtained from the ratio of spectral densities G*/sub 12/G/sub 13//G/sub 11/G/sub 23/ agreed with those from break-frequency noise analysis and with bias-corrected transport theory calculations within the statistical uncertainty of the measurements. Corrections for the effects of spatial modes and source-detector locations appear to be well-understood, since measurements for a variety of source-detector positions resulted in essentially the same kappasub(eff)-values. Modal correction factors were such that ignoring them would result in higher values of kappasub(eff) than actually occur. The measurements have demonstrated the applicability of the /sup ...
1986-01-01
Analyses of postulated accidental releases of UF6 inside process buildings
International Nuclear Information System (INIS)
Uranium Hexafluoride is a material used in the various processes which comprise the front end of the nuclear fuel cycle (conversion, enrichment and fuel fabrication). Confinement of UF6 is a very important safety requirement since this material is highly reactive and presents safety hazards to humans. The present paper discusses the safety relevant aspects of accidental releases of UF6 inside process confinement buildings. Postulated accidental scenarios are analyzed and their consequences evaluated. Implant releases rates are estimated using computer code predictions. A time dependent homogeneous compartment model is used to predict concentrations of UF6, hydrogen fluoride and uranyl fluoride inside a confinement building, as well as to evaluate source terms released to the atmosphere. These source terms can be used as input to atmospheric dispersion models to evaluate consequences to the environment. The results can also be used to define ...
Anti-proton and positron Galactic cosmic ray (GCR) spectra are among the key targets for indirect detection of dark matter (DM). The boost factors, corresponding to an enhancement of the signal|linked to the clumpiness properties of the dark matter distribution|, have been taken as high as thousands in the past. The dramatic impact of these boost factors for indirect detection of antiparticles, for instance with the PAMELA satellite or the coming AMS-02 experiment, asks for their detailed calculation. We take into account the state-of-the-art results of high resolution N-body dark matter simulations to calculate the most likely energy dependent boost factors|linked to the GCR propagation properties|, for anti-protons and positrons. The results from extreme, but still possible, configurations of the clumpy dark matter component is also discussed. Starting from the mass and space distributions of sub-halos, the anti-proton and ...
2007-01-01
Electronics for the Si detectors in APEX
Energy Technology Data Exchange (ETDEWEB)
APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) and the integration of the CFD and PTF with ...
1994-07-01
International Nuclear Information System (INIS)
The macrotemporal structure of the Super-ACO Storage ring free-electron laser (FEL) can be either continuous, pulsed, or chaotic, and can present some rapid fluctuations. The temporal evolution of a storage ring FEL involves both the longitudinal motion of the positron beam (especially the synchrotron oscillations) and the FEL dynamics, as in a coupled system. Studies on the dynamics of the positron beam are performed here, in the goal to have a stable source for FEL applications, and to determine the conditions for a stable Q-switching experiment. The employed method is to study the influence of a controlled change of the radio frequency (RF) (modulation or frequency jump) on the beam. A simple theoretical model taking into account the perturbed RF system is presented to help the understanding of the experimental data. The different methods of measurement are described. Then, the results are given for several experimental conditions and the ...
Energy Technology Data Exchange (ETDEWEB)
In order to remove ash from coal, it is introduced into an aqueous ash removal solution, which contains nitric acid or citric acid and ammonium hydrogen fluoride. The coal without ash is then separated from the aqueous solution. According to the process, either finely ground coal is introduced into the ash removel solution or the coal with the solution is ground in a wet pulveriser.
1981-03-13
Energy Technology Data Exchange (ETDEWEB)
This patent describes a process for preparing poly(aryl ether ketones) by nucleophilic displacement polymerization in the presence of at least one alkali metal base selected from potassium, rubidium or cesium, and fluoride ions, which comprises adding to the polymerization: (a) an effective amount of at least one metal salt selected from lithium, sodium, alkaline earth or lanthanide chloride, bromide, iodide, sulfate, alkyl or aryl carboxylate, cyanide, borate or phosphate to slow or stop advancement of molecular weight and (b) an end-capping agent.
1988-09-27
Passivation-free solid state battery
Energy Technology Data Exchange (ETDEWEB)
This invention pertains to passivation-free solid-state rechargeable batteries composed of Li.sub.4 Ti.sub.5 O.sub.12 anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn.sub.2 O.sub.4, LiCoO.sub.2, LiNiO.sub.2 and LiV.sub.2 O.sub.5 and their derivatives.
1998-01-01
Passivation-free solid state battery
Energy Technology Data Exchange (ETDEWEB)
This invention pertains to passivation-free solid-state rechargeable batteries composed of Li{sub 4}Ti{sub 5}O{sub 12} anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn{sub 2}O{sub 4}, LiCoO{sub 2}, LiNiO{sub 2} and LiV{sub 2}O{sub 5} and their derivatives. 5 figs.
1998-06-16
Exposure of the freshwater field crab Barytelphusa guerini to a sublethal concentration of NaF (30 mg litre(-1)) caused significant alterations in protein metabolism. After an exposure time of 15 days, the crab was found to have a marked depletion of total protein and free amino acid content. A significant elevation in transaminases, Aspartate aminotransferase (AAT) and Alanine aminotransferase (ALAT), and Glutamate dehydrogenase (GDH) activities was reflected in the free amino acid levels of the tissues. PMID:15092215
1990-01-01
Fatalities resulting from sulfuryl fluoride exposure after home fumigation-Virginia
Energy Technology Data Exchange (ETDEWEB)
On September 25, 1986, an elderly Virginia couple had their home fumigated by a local pest extermination company for the control of wood-boring insects. Two hundred and fifty pounds of sulfurylfluoride (SF), a colorless, odorless fumigant gas commonly used for this purpose, was applied in the approximately 80,000-cubic-foot home that date. Within 1 week, both husband and wife were dead. Because both deaths occurred within a short period of time and the wife's illness was compatible with toxic gas inhalation, these deaths were then thought to be related to the home fumigation.
1987-10-16
Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note
Energy Technology Data Exchange (ETDEWEB)
The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.
1986-01-01
International Nuclear Information System (INIS)
The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)
1998-01-01
Energy Technology Data Exchange (ETDEWEB)
The formation, migration and agglomeration in silicon of fluorine-vacancy complexes have been monitored by single-detector Doppler broadening spectroscopy. After electronics engineers found that fluorine ion implantation effectively eliminated the transient-enhanced diffusion of dopants in the creation of ultra-shallow junctions, a vital step in the further miniaturization of device structures, positron beams have played a pivotal role in providing an insight into the mechanisms underlying this phenomenon, being able to detect FV complexes in implanted and annealed samples. Secondary Ion Mass Spectrometry has provided complementary information on fluorine concentrations so that the nature of the F{sub m}V{sub n} complexes can be further assessed. New results on Si and SiGe structures are presented.
2008-10-31
Energy Technology Data Exchange (ETDEWEB)
The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.
1995-09-01
Using the complex Kohn method, we have calculated variational values of phase shifts and the annihilation parameter, Z_{eff}, for the elastic scattering of positrons by molecular hydrogen. Our results are sensitive to small changes in the accuracy of the wave function representing the target hydrogen molecule. We have developed a systematic approach to demonstrate that, at low positron energies, there are particular forms of the Kohn trial wave function for which the results of variational calculations are not reliable, even when the target wave function accounts for as much as 96.8% of the correlation energy of H_{2}. We find that reliable results can be recovered if our calculations are extended to admit more sophisticated target wave functions accounting for 99.7% of the correlation energy. Remaining discrepancies between theory and experiment are briefly discussed.
2008-01-01
Synthesis of C-11 iodoantipyrine for positron emission tomography
Energy Technology Data Exchange (ETDEWEB)
We have developed a method for the synthesis of C-11 iodoantipyrine. Carbon-11-labeled methyl iodide, prepared from /sup 11/CO2, was used to methylate 3-methyl-1-phenyl-2-pyrazolin-5-one to form C-11 antipyrine. Following silica-gel column chromatography and iodination, radiochemical purity of the C-11 iodoantipyrine was more than 99.5%, with a 10% yield and a specific activity of 30 mCi/mumol. Preliminary animal studies showed complete cerebral extraction and local cerebral blood-flow values that were within 4.6% of those obtained using C-14 iodoantipyrine. The C-11 analog, with positron emission tomography, will facilitate local cerebral blood-flow studies in human subjects.
1981-06-01
Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer ...
2008-01-01
Development of a new #gamma#-ray detector for PEM applications
International Nuclear Information System (INIS)
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
2007-05-01
Cosmic-ray antiprotons, positrons, and gamma rays from halo dark matter annihilation
Energy Technology Data Exchange (ETDEWEB)
The subject of cosmic ray antiproton production is reexamined by considering other choices for the nature of the Majorana fermion chi other than the photino considered in a previous article. The calculations are extended to include cosmic-ray positrons and cosmic gamma rays as annihilation products. Taking chi to be a generic higgsino or simply a heavy Majorana neutrino with standard couplings to the Z-zero boson allows the previous interpretation of the cosmic antiproton data to be maintained. In this case also, the annihilation cross section can be calculated independently of unknown particle physics parameters. Whereas the relic density of photinos with the choice of parameters in the previous paper turned out to be only a few percent of the closure density, the corresponding value for Omega in the generic higgsino or Majorana case is about 0.2, in excellent agreement with the value associated with galaxies and one which is sufficient to give the halo mass. 52 ...
1988-02-01
Antimatter production in supernova remnants
We calculate the energy spectra of cosmic rays (CR) and their secondaries produced in a supernova remnant (SNR), taking into account the time-dependence of the SNR shock. We model the trajectories of charged particles as a random walk with a prescribed diffusion coefficient, accelerating the particles at each shock crossing. Secondary production by CRs colliding with gas is included as a Monte Carlo process. We find that SNRs produce less antimatter than suggested previously: The positron/electron ratio and the antiproton/proton ratio are a few percent and few $\\times 10^{-5}$, respectively. Moreover, the obtained positron/electron ratio decreases with energy, while the antiproton/proton ratio rises at most by a factor of two above 10 GeV.
2011-01-01
UK PubMed Central (United Kingdom)
We characterized the absorption and short-term translocation of cadmium (Cd) in rice (Oryza sativa ‘Nipponbare’) quantitatively using serial images observed with a positron-emitting...Full Text Available
2010-04-01
Energy Technology Data Exchange (ETDEWEB)
The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.
2009-03-15
International Nuclear Information System (INIS)
By the methods of the angular distribution of photon annihilation, time distribution of photon annihilation, photoluminescence spectroscopy, Fourier IR-spectroscopy, atomic force microscopy the detail information on relation of the structural and physical properties of the porous nano-structures is obtained. Study of pores sizes in a different nano-porous materials, such as the porous silicon, porous anode aluminium oxide, porous solids exposed to light atoms ion implantation (hydrogen, deuterium, helium) is carried out.
2003-09-15
UK PubMed Central (United Kingdom)
OBJECTIVES: To assess the suitability of analyzing functional images of brain serotonin (5-HT) synthesis with statistical parametric mapping (SPM), and to investigate further possible sex-related regional...Full Text Available
2000-09-01
PET and MR imaging in a neuro-Behcet syndrome
Energy Technology Data Exchange (ETDEWEB)
Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).
1989-11-01
P and e identification capabilities CAPRICE
Energy Technology Data Exchange (ETDEWEB)
The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.
1995-09-01
Origin of the low-energy cosmic-ray antiprotons
Energy Technology Data Exchange (ETDEWEB)
A model for generating the observed cosmic-ray antiproton spectrum in plasma consisting mainly of electron--positron pairs (n/sub plus-or-minus//n/sub p/> or approx. =10) is discussed. Coulomb collisions in the plasma would cause additional energy losses, significantly enhancing the antiproton flux at energies < or approx. =1 GeV. The computed p-bar/p ratio satisfactorily fits the observations.
1983-01-01
Nature of low-energy antiprotons in cosmic rays
Energy Technology Data Exchange (ETDEWEB)
A model of formation of cosmic ray antiproton spectrum in plasma consisting mainly of electron-positron pairs (nsub(+-)/nsub(p) > or approximately 10) is considered. Additional energy losses due to Coulomb collisions in plasma provide significant increase of the antiproton flux in the energy range < or approximately 1 GeV. Calculated anti p/p ratio is in a satisfactory agreement with the observational data.
1983-02-01
Measurements of Cabibbo Suppressed Hadronic Decay Fractions of Charmed D0 and D+ Mesons
Using data collected with the BESII detector at $e^{+}e^{-}$ storage ring Beijing Electron Positron Collider, the measurements of relative branching fractions for seven Cabibbo suppressed hadronic weak decays $D^0 \\to K^- K^+$, $\\pi^+ \\pi^-$, $K^- K^+ \\pi^+ \\pi^-$ and $\\pi^+ \\pi^+ \\pi^- \\pi^-$, $D^+ \\to \\bar{K^0} K^+$, $K^- K^+ \\pi^+$ and $\\pi^- \\pi^+ \\pi^+$ are presented.
2005-01-01
Induced radiation during scattering of channeled electrons and positrons by point defects
Energy Technology Data Exchange (ETDEWEB)
In scattering of channeled particles by point defects and in emission of gamma rays in the spontaneous-radiation spectral region conditions are attained where the momentum transferred to the defect is taken up by the crystal as a whole. This leads to coherent and interference effects in the radiation from the crystal defects. When the longitudinal momentum transferred is zero, an induced radiation effect appears in the transitions between the states of transverse motion.
1984-12-01
Development of an experimental installation for short-lived isotopes production in INR linac
International Nuclear Information System (INIS)
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
2010-01-01
CAIN: Conglomerat d`ABEL et d`Interactions Non-lineaires
Energy Technology Data Exchange (ETDEWEB)
We present our plans for a Monte-Carlo code simulating all possible combinations of (electromagnetic) interactions between colliding electron, positron, and both high-energy and laser photon beams, based on the ABEL code for beam-beam interaction. The implementation and first results for the laser-e{sup -} interaction are described. ((orig.)).
1995-02-01
CAIN: Conglomerat d'ABEL et d'interactions non-lineaires
International Nuclear Information System (INIS)
We present our plans for a Monte-Carlo code simulating all possible combinations of (electromagnetic) interactions between colliding electron, positron, and both high-energy and laser photon beams, based, on the ABEL code for beam-beam interaction. The implementation and first results for the laser-e"- interaction are described.
1994-03-28
Surface modification on magnesium alloys by coating with magnesium fluorides
Energy Technology Data Exchange (ETDEWEB)
A new technique has been developed for improving corrosion resistance on magnesium alloys. Specimens of AZ31 magnesium alloy were dipped into molten salt of NaBF{sub 4} at 723 K for various times, and then cooled, rinsed with water, and dried in air. Corrosion resistance in the surface treated specimens was evaluated by salt immersion test using 1% NaCl solution as a time for occurring filiform corrosion. On an un-treated AZ31 alloy, the time for starting the filiform corrosion was about 1.2 ks, while on the surface treated specimen, the time was prolonged into about 1300 ks. Moreover, the surface treated specimen showed corrosion resistance in low pH solutions, such as 1% HNO{sub 3} and HCl solutions. (orig.)
2005-07-01
International Nuclear Information System (INIS)
Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion tests.
2011-02-01
Energy Technology Data Exchange (ETDEWEB)
The lithium carbon batteries studied in this paper use plasticized polymer electrolytes made with passive polymer matrix swollen by a liquid electrolyte with a high ionic conductivity (> 10{sup -3} S/cm at 25 deg. C). The polymers used to prepare the gels are polyacrylonitrile (PAN) and vinylidene poly-fluoride (PVdF). The electrochemical and physical properties of these materials are analyzed according to their composition. The behaviour of solid electrolytes with different materials of lithium ion insertion (graphite and LiNiO{sub 2}) are studied and compared to liquid electrolytes. The parameters taken into account are the reversible and irreversible capacities, the cycling performance and the admissible current densities. Finally, complete lithium ion batteries with gelled electrolytes were manufactured and tested. (J.S.) 2 refs.
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
A 15-nm lithium fluoride (LiF) thin film evaporated on glass substrate is shown to enhance the nucleation of microcrystalline Si grown by plasma enhanced chemical vapour deposition at the amorphous/microcrystalline boundary conditions. The effect is more pronounced at low substrate temperatures, nucleation density being 10 times higher at {approx} 80 {sup o}C. The effect is ascribed to the ionic chemical nature of LiF, the low work function material used in organic electronic devices, and we propose its use for micro patterning crystalline Si regions in otherwise amorphous Si film.
2009-10-30
International Nuclear Information System (INIS)
We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF_2"+) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF_2"+ implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.
2002-01-01
British Library Electronic Table of Contents (United Kingdom)
Fluorocarbon polymers are used to enhance thermal stability and electrostatic protection of composite propellant compositions. A precipitation technique has been developed to coat ammonium perchlorate (AP) using a copolymer of hexafluoropropylene and vinylidene fluoride (HFP-VF) with the help of solvent-counter solvent method. The coated AP has been used to prepare propellant compositions in different ratio based on hydroxyl terminated polybutadiene (HTPB), aluminium powder along with uncoated AP and studied for viscosity build-up and visco-elastic behaviour as well as mechanical, ballistic, thermal and sensitivity properties keeping 86% solid loading. The data on viscosity build-up indicate that as the percentage of viton coated AP increases end of mix viscosity and viscosity build-up inc...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Decontamination and decommission activities related to the Molten Salt Reactor Experiment (MSRE) involve the trapping and recovery of radiolitically generated uranium hexafluoride and fluorine. Although fission product radiolysis was known to generate F{sub 2}, the formation of UF{sub 6} and its transport from the fuel salt was unexpected. Some of these gaseous radiolysis products have been moving through the gas piping to a charcoal bed since the reactor was shut down in 1969. Current and planned remediation and clean-up activities involve the trapping of the gaseous products, deactivation and treatment of the activated charcoal bed, stabilization and reconditioning of the fuel salt, and recovery of the uranium. The chemical aspects of these processes, including radiolytic generation mechanisms, reactions between uranium hexafluoride and fluorine and trapping materials such as activated charcoal, activated alumina, and sodium fluoride, along with the analytical ...
1996-10-01
A comparison of patient doses in lumbar spine radiography from various X-ray units in Poland
Energy Technology Data Exchange (ETDEWEB)
A number of diagnostic X-ray units in Poland were subjected to analysis. The air kerma on X-ray tables was measured for the X-ray parameters used routinely during lumbo-sacral spine radiography of standard adult patient. Measurements of air kerma were performed using TLD made of lithium-fluoride. The doses received by patients in different X-ray departments can differ more than two orders of magnitude (from 0.42 mGy up to 72.11 mGy), for the same X-ray examination. The dose can be significantly reduced if fluorescent screens made from components of rare earth are used. (author). 10 refs, 1 fig., 2 tabs.
1995-12-31
Ultra high-speed (508 MHz) beam position digital feedback system
Energy Technology Data Exchange (ETDEWEB)
The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters ...
1997-02-01
Strong-field quantum-electrodynamic processes in aligned crystals
Energy Technology Data Exchange (ETDEWEB)
When a highly collimated beam of particles is aimed along the atomic rows of an aligned single crystal, the averaging effect of high speed motion results, to the lowest order of approximation, in crystal electric fields which are transverse to the atomic rows. The enormous magnitude of the crystal transverse electric fields is unsurpassed by any other known earth-bound macroscopic sources. For example, the field strengths along the <100> axis of tungsten at 77 K approach 9{center dot}10{sup 13}V/m. Thus quantum electrodynamic (QED) processes in strong fields which are thought to occur only in the extra-terrestrial environment can now be investigated in the laboratory. Here we review the results of measurements performed at the SPS facility in CERN using highly collimated beams of electrons, positrons and photons in the 20-200 GeV range, and germanium crystals cooled to 77 K with thicknesses ranging from 0.07 mm to 1.40 mm. The focus is on the simplest ...
1989-01-01
Production of radiopharmaceuticals for positron emission tomography via laboratory robotics
International Nuclear Information System (INIS)
The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the synthesis of several short-lived ...
1987-11-15
Positrons and antiprotons from inert doublet model dark matter
We investigate the signatures of antimatter in cosmic rays that would result from annihilations of the scalar dark matter candidate of the Inert Doublet Model. We consider three benchmark candidates, all consistent with the WMAP cosmic abundance and existing direct detection experiments, and confront the predictions of the model with the recent PAMELA, ATIC and HESS data. For a light IDM WIMP candidate, M_{DM} = 10 GeV, we argue that the positron and antiproton fluxes are large, but consistent with expected backgrounds, unless there is an enhancement in the local density of dark matter. For an IDM WIMP candidate with M_{DM} = 70 GeV, the contribution is lower than the expected backgrounds unless there is a large boost factor. However, the candidate is enable to explain the excesses observed by the recent experiments. Finally, for an IDM WIMP candidate with M_{DM}=10 TeV, it is possible to fit the PAMELA excess, while satisfying the anti-protons data, but, ...
2009-01-01
Performance of the AMS-02 Experiment for High Energy Gamma Ray Astrophysics
AMS is a particle detector designed to perform high precision measurements of the cosmic rays fluxes with the main goals of searching for anti-nuclei, as remnants of primordial anti-matter, and of measuring the faintest components of the cosmic flux, anti- protons, positrons and high energy photons. To fulfill the requirements of large acceptance, long exposure time and excellent particle identification needed to achieve the intended results, AMS will operate in space as an attached payload to the International Space Station (ISS), being the first full featured particle physics experiment to operate in the Earth orbit. The AMS-02 accurate measurements of cosmic-ray nuclei, protons, antiprotons, electrons and positrons will be completed by high energy gamma rays detection. The experiment will detect gamma-rays, either by reconstructing e+e? pairs generated by photons converted upstream the tracker (conversion mode), or based on direct ...
2007-01-01
Current trends in ion implantation
Energy Technology Data Exchange (ETDEWEB)
As semiconductor device dimensions continue to shrink, the drive beyond 250 nm is creating significant problems for the device processor. In particular, trends toward shallower-junctions, lower thermal budgets and simplified processing steps present severe challenges to ion implantation. In parallel with greater control of the implant process goes the need for a better understanding of the physical processes involved during implantation and subsequent activation annealing. For instance, the need for an understanding of dopant-defect interaction is paramount as defects mediate a number of technologically important phenomena such as transient enhanced diffusion and impurity gettering. This paper will outline the current trends in the ion implantation and some of the challenges it faces in the next decade, as described in the semiconductor roadmap. It will highlight some recent positron annihilation work that has made a contribution to addressing one of these ...
2001-07-01
International Nuclear Information System (INIS)
In cases of obstructive colorectal cancer (CRC), preoperative diagnosis of the proximal lesion is often difficult when the primary lesion impedes the passage of the endoscope. The aim of this study was to evaluate the usefulness of fluorine-18-fluorodeoxyglucose positron emission tomography (FDG-PET) in such cases. A total of 52 obstructive CRC patients who underwent preoperative FDG-PET and subsequent surgical resection were retrospectively reviewed. The correlation between characteristics of the proximal lesion and FDG-PET findings was analyzed statistically. There was a significant correlation between the proximal lesion size and the maximum standardized uptake value (P=0.00016). Abnormal FDG accumulation in the proximal colon indicated the existence of proximal cancer or adenoma with a sensitivity of 50% and a specificity of 100%. There was a significant difference in the distribution of tumor size between the cases with proximal abnormal accumulation and those ...
2010-10-01
Antideuterons from Dark Matter Decay
Recent observations of a large excess of cosmic-ray positrons at high energies have raised a lot of interest in leptonic decay modes of dark matter particles. Nevertheless, dark matter particles in the Milky Way halo could also decay hadronically, producing not only a flux of antiprotons but also a flux of antideuterons. We show that for certain choices of parameters the antideuteron flux from dark matter decay can be much larger than the purely secondary flux from spallation of cosmic rays on the interstellar medium, while the total antiproton flux remains consistent with present observations. We show that if the dark matter particle is sufficiently light, the antideuteron flux from dark matter decay could even be within the reach of planned experiments such as AMS-02 or GAPS. Furthermore, we discuss the prospects to observe the antideuteron flux in the near future if the steep rise in the positron fraction reported by the PAMELA collaboration ...
2009-01-01
Silicidation in Pd/Si thin film junction-Defect evolution and silicon surface segregation
Energy Technology Data Exchange (ETDEWEB)
Depth resolved positron annihilation studies on Pd/Si thin film system have been carried out to investigate silicide phase formation and vacancy defect production induced by thermal annealing. The evolution of defect sensitive S-parameter clearly indicates the presence of divacancy defects across the interface, due to enhanced Si diffusion beyond 870 K consequent to silicide formation. Corroborative glancing incidence X-ray diffraction (GIXRD), Auger electron spectroscopy (AES) and Rutherford backscattering spectrometry (RBS) have elucidated the aspects related to silicide phase formation and Si surface segregation.
2007-09-25
Search for K_S K_S in J/psi and psi(2S) decays
The CP violating processes J/psi-->K_S K_S and psi(2S)-->K_S K_S are searched for using samples of 58 million J/psi and 14 million psi(2S) events collected with the Beijing Spectrometer at the Beijing Electron Positron Collider. No signal is observed, and upper limits on the decay branching ratios are determined to be BR(J/psi-->K_S K_S) K_S K_S) < 4.6x10^{-6} at the 95% confidence level.
2004-01-01
Polarizing a stored proton beam by spin flip?
International Nuclear Information System (INIS)
We discuss polarizing a proton beam in a storage ring, either by selective removal or by spin flip of the stored ions. Prompted by recent, conflicting calculations, we have carried out a measurement of the spin-flip cross section in low-energy electron-proton scattering. The experiment uses the cooling electron beam at COSY as an electron target. The measured cross sections are too small for making spin flip a viable tool in polarizing a stored beam. This invalidates a recent proposal to use co-moving polarized positrons to polarize a stored antiproton beam.
2009-04-27
PET/CT-guided interventional procedures: rationale, justification, initial study, and research plan
International Nuclear Information System (INIS)
Positron-emission tomography (PET) and PET/CT (computed tomography) are becoming increasingly important for diagnosis and treatment of cancer. Clinically relevant changes can sometimes be seen on PET that are not seen on other imaging modalities. However, PET is not suitable for guiding biopsy as the images are not obtained in real-time. Therefore, our research group has begun developing a concept for PET/CT-guided interventional procedures. This paper presents the rationale for this concept, outlines our research plan, and includes an initial study to evaluate the relative sensitivity of CT and PET/CT in detecting suspicious lesions. (orig.)
2007-06-01
PET/CT cardiology: an area whose boundaries are still out of sight
International Nuclear Information System (INIS)
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
2006-05-01
Observation of p pbar pi^0 and p pbar eta in psi' decays
The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.
2005-01-01
Improved measurement of the branching ratio of J/psi-->K_S K_L
The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.
2004-01-01
High energy beams of radioactive nuclei and their biomedical applications
Energy Technology Data Exchange (ETDEWEB)
It is possible to produce energetic beams of radioactive nuclei, as secondary beams, from the heavy-particle compound accelerator called BEVALAC. These beams can be focused into experimental areas without significant contamination using suitable magnetic filters and proper beam-optics. Properly selected high-energy beams of radioactive nuclei (those which defay by positron emission) can provide a truly unique opportunity to evaluate the effectiveness of these beams in localizing the Bragg peak on a tumor volume - necessary in heavy-particle therapy. Preliminary data are presented here to demonstrate the possible use of these beams in radiotherapy treatment-planning verification.
1981-04-01
Electronic structure calculations of vacancies and their influence on materials properties
Energy Technology Data Exchange (ETDEWEB)
We provide two examples to illustrate how electronic structure calculations contribute to our understanding of vacancies and their role in determining material properties. Diffusion and elctromigration in aluminium are known to depend strongly on vacancies. Electronic structure calculations show that the vacancy-impurity interaction oscillates with distance, and this leads to an explanation for both the increased elctromigration resistance and the slow impurity diffusion for copper in aluminium. Calculations of vacancies in plutonium have been used in conjunction with positron annihilation lifetime measurements to identify the presence of helium-filled vacanies. Helium stabilization of vacancies can provide the precursors for subsequent vacancy-related changes in materials properties.
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
We have made preliminary estimates of charged particles background at the 100x100 GeV Photon Linear Collider with ultimate luminosity. The charged particles background due to electromagnetic processes is located mainly in the small-angle range of the detector. At large angles, the number of background particles is much smaller. Analysis of the background (at least, in the range under consideration) shows that background conditions for the VLEPP-based Photon Linear Collider are better than at the VLEPP electron-positron collider. ((orig.)).
1995-02-01
PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.
2008-01-01
International Nuclear Information System (INIS)
The inelastic scattering of the beam and the residual gas molecules in RHIC could represent one of the limitations on the beam life time and emittance growth. This report covers the dominant central nuclear collisions influence on the beam lifetime and transverse emittance growth. The cross sections for the beam-gas electron radiative captures are an order of magnitude smaller. The capture cross sections include the radiative and non-radiative capture, and the capture from the electron-positron pair creation from the 'vacuum capture'.
2010-09-01
Anomalous positron excess from Lorentz-violating QED
We entertain the idea that a suitable background of cold (very low momentum) pseudoscalar particles or condensate, may trigger a background that effectively generates Lorentz-invariance violation. This aether-like background induces a Chern-Simons modification of QED. Physics is different in different frames and, in the rest frame of the pseudoscalar background, high momentum photons can decay into pairs. The threshold for such decay depends quadratically on the rest mass of the particles. This mechanism could explain in a natural way why antiprotons are absent in recent cosmic ray measurements. A similar signal could be used as a probe of pseudoscalar condensation in heavy ion collisions.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The liquid-liquid extraction behavior of short-lived molybdenum and tungsten isotopes from HCl and HNO{sub 3} as well as HF/HNO{sub 3} acid media was studied using the {alpha}-benzoinoxime/chloroform system. The goal of the present experiments was to find an extraction system with a high selectivity for the group 6 elements in the periodic table which is suitable for the study the solution chemistry of seaborgium (Z = 106). It was found that Mo and W are both effectively extracted using {alpha}-benzoinoxime as an extractant and the maximum extraction yield is 100% and 94% for Mo and W, respectively. Ions of MO{sub 2}{sup 2+} (M = Mo, W) exist in HCl between the concentration range of 0.1-3 M and can be extracted quantitatively into the organic phase. The decrease of extraction yields at lower or higher acid concentration is due to the formation of anionic species MO{sub 4}{sup 2-} or MO{sub 2}Cl{sub 3}{sup -}. The extraction behavior of Mo and W in HNO{sub 3} solution is similar to ...
2009-07-01
International Nuclear Information System (INIS)
The liquid-liquid extraction behavior of short-lived molybdenum and tungsten isotopes from HCl and HNO_3 as well as HF/HNO_3 acid media was studied using the #alpha#-benzoinoxime/chloroform system. The goal of the present experiments was to find an extraction system with a high selectivity for the group 6 elements in the periodic table which is suitable for the study the solution chemistry of seaborgium (Z = 106). It was found that Mo and W are both effectively extracted using #alpha#-benzoinoxime as an extractant and the maximum extraction yield is 100% and 94% for Mo and W, respectively. Ions of MO_2"2"+ (M = Mo, W) exist in HCl between the concentration range of 0.1-3 M and can be extracted quantitatively into the organic phase. The decrease of extraction yields at lower or higher acid concentration is due to the formation of anionic species MO_4"2"- or MO_2Cl_3"-. The extraction behavior of Mo and W in HNO_3 solution is similar to that in HCl solution. In HNO_3/HF mixed acid ...
Electrochemical behavior of Ti-Cr alloys in artificial saliva
Energy Technology Data Exchange (ETDEWEB)
In this study, the corrosion behavior of commercially pure titanium (c.p. Ti), Ti-6Al-4V and five new experimental Ti-Cr alloys was evaluated through open-circuit potential (OCP) and potentiodynamic polarization measurement in an artificial saliva containing fluoride. Electron spectroscopy for chemical analysis (ESCA) was used to characterize the composition of the passive films on the alloy after potentiodynamic polarization measurement. It was found that in standard artificial saliva the OCP increases with higher Cr content in Ti-Cr alloys. In 0.5% NaF artificial saliva, the OCP decreases with decreasing Cr in Ti-Cr alloys, and all but Ti-5Cr remain consistently higher than those of c.p Ti and Ti-6Al-4V. Linear polarization results show that artificial saliva and artificial saliva containing 0.5% NaF result in different corrosion behavior in Ti-Cr alloys, c.p.Ti and Ti-6Al-4V. The Ti-Cr alloys had greater resistance to corrosion in the ...
2009-11-13
Electrochemical behavior of Ti-Cr alloys in artificial saliva
International Nuclear Information System (INIS)
In this study, the corrosion behavior of commercially pure titanium (c.p. Ti), Ti-6Al-4V and five new experimental Ti-Cr alloys was evaluated through open-circuit potential (OCP) and potentiodynamic polarization measurement in an artificial saliva containing fluoride. Electron spectroscopy for chemical analysis (ESCA) was used to characterize the composition of the passive films on the alloy after potentiodynamic polarization measurement. It was found that in standard artificial saliva the OCP increases with higher Cr content in Ti-Cr alloys. In 0.5% NaF artificial saliva, the OCP decreases with decreasing Cr in Ti-Cr alloys, and all but Ti-5Cr remain consistently higher than those of c.p Ti and Ti-6Al-4V. Linear polarization results show that artificial saliva and artificial saliva containing 0.5% NaF result in different corrosion behavior in Ti-Cr alloys, c.p.Ti and Ti-6Al-4V. The Ti-Cr alloys had greater resistance to corrosion in the ...
2009-11-13
International Nuclear Information System (INIS)
Full text: Groundwater in rural agricultural area of South Korea is an important source of drinking and agricultural water. The study area is located in mid-western coastal parts and has fractured bedrock aquifers whose lithologies are composed of Jurassic granites, Paleozoic sedimentary rocks, Precambrian schists and gneiss. Bedrock groundwater was slightly alkaline and had electrical conductivity of 40 to 1570 #mu#S/cm with median values of 322 #mu#S/cm. Water types based on major ions showed that Ca-HCO_3 and Ca-CI types are dominant and Na-HCO_3 and Na-CI types are minor. Intense agricultural activities resulted in significant nitrate contamination of groundwater. 22% and 40% of wells have exceeded drinking water standards (DWS) for bedrock and shallow wells, respectively. In coastal areas, slightly saline groundwater is observed for both bedrock and shallow wells. Groundwater in granitic rocks may have higher concentrations of Rn, U and F. Most wells had ...
2010-11-15
Energy Technology Data Exchange (ETDEWEB)
Positron Emission Tomography (PET) was used to analyze in vivo antagonist binding to human myocardial muscarinic cholinergic receptor. The methiodide salt of the muscarinic antagonist, quinuclidinyl benzilate (MQNB), was labeled with the positron emitter, Carbon-11, and injected intravenously to 8 normal subjects. /sup 11/C-MQNB concentration was determined in vivo in the ventricular septum from 40 cross-sectional images acquired at the same transverse level over a period of 70 minutes. In 4 subjects, various amounts of unlabeled atropine were rapidly injected at 20 minutes to study whether atropine competitively inhibited MQNB. The kinetics of binding of /sup 11/C-MQNB were not the same in vivo and in vitro. The apparent dissociation rate of /sup 11/C-MQNB in vivo was much slower (by 1 to 2 orders of magnitude) than that observed in vitro with /sup 3/H-QNB. After atropine injection, /sup 11/C-MQNB dissociated from its binding sites at a rate ...
1984-08-27
A study of Pd-Ta on Si(100) using AES, RBS and variable energy positron annihilation
The applicability of Pd/sub x/Ta/sub 1-x/ as a diffusion barrier on Si has been investigated. For this purpose Pd/sub x/Ta/sub 1-x/ films of 200 nm thickness (x ranges from 0 to 1) were deposited on Si(100), and the reaction between over-layer and substrate was studied as a function of temperature. Interaction was found to occur at temperatures increasing with the Ta content. The as-deposited Pd/sub x/Ta/sub 1-x/ films with 0.2 less than or equal to x less than or equal to 0.6 were found to be amorphous. The amorphous phase had a higher reaction temperature than the crystalline one, causing a discontinuous step in the reaction temperature. RBS spectra revealed that for the Pd-rich compositions first a stoichiometric Pd2Si layer formed underneath a pure Ta layer. At higher temperatures TaSi2 formed at the surface. For Ta-rich compositions Pd2Si formed first as well, however, the reaction temperature was so high that Pd2Si grains formed in a Si matrix. The defect density of the Ta layer, ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
The durability of ball bearings, 32-mm- and 45-mm-bore, with a retainer or glass cloth-polytetrafluoroethylene (PTFE) laminate was tested under a high radial load at a speed of 20,000 rpm in LOX or LN2. The retainers were characterized as good self-lubricators because the abrasive glass-cloth fiber tips exposed on the retainer were chemicaly etched away with hydrofluoric acid (HF). During testing, the bearing-cartridge-acceleration was monitored to detect bearing damage. Testing in LOX for about 2.2 hr showed that excellent lubricating conditions were obtained for all bearings. Testing in LN2 for about 5.1 hr detected that the fatigue life of the bearing was about the same as the calculated B10 fatigue life. The HF chemical treatment resulted in a reacted fluoride-oxide material which remained in the etched part of the glass fiber. Several chemical products, particularly MgO, CaO, and CaCO3, enhanced adhesion of PTFE transfer film to the counterface, resulting in ...
1993-09-01
Quantitative monitoring of the fluorination process by neutron counting
Energy Technology Data Exchange (ETDEWEB)
Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. Neutrons are counted with polyethylene-moderated {sup 3}He-gas proportional counters. ...
1993-12-31
Photo-induced transformation of close Frenkel pairs in strontium fluoride
International Nuclear Information System (INIS)
Laser-induced change is studied of the optical absorption and luminescence due to F-H pairs generated by an electron pulse in SrF_2. It is found that laser irradiation near 2.34 eV at a delay of 26 #mu#s after an electron pulse by which F-H pairs are generated reduces the component I of the pairs that has a decay time of 59 #mu#s and optical absorption bands at 2.34 and 4.13 eV and enhances the component II that has a decay time of 7.7 ms and has optical absorption bands at 2.7 and 3.35 eV. Laser irradiation near 2.7 eV at a delay of 4 ms after the electron pulse is found to induce the reverse reaction. Studies of dichroism of the laser-induced reduction and enhancement of the optical absorption bands and the luminescence reveal that the direction of the #SIGMA#-#SIGMA# transition of the F_2"- molecular ion is converted by the transformation from I to II and vice versa. It is suggested that the component I corresponds to the F-H pairs at nearest-neighbour and II to those at the ...
Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium
Energy Technology Data Exchange (ETDEWEB)
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons and gamma rays are resolved in both time and energy to reveal ...
2004-03-09
Low-temperature phase transitions and magnetic susceptibilities of low-dimensional uranium fluorides
International Nuclear Information System (INIS)
Measurements have been made on the magnetic susceptibilities of the quasi-one-dimensional magnetic #approx#-UF_5 and the cluster magnetic U_2F_9 (a four-nuclear type) over the range 4.2-300 K. The Curie-Weiss law applies for #approx#-UF_5 above 200 K, with #mu#ef = 2.37#mu#B, theta = -148 K; that law also applies to U_2F_9 above 150 K, with #mu#ef = 2.9#mu#B and theta = 118 K. The antiferromagnetic ordering is discussed for the one-dimensional chains in #approx#-UF_5 together with the phase transition observed in U_2F_9 at 6 K. It is assumed that the U"4"+ and U"5"+ valency states are stabilized below the phase-transition point, and only then can U_2F_9 be considered as the compound UF_4 x UF_5.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
We have simulated the transient enhanced diffusion (TED) of boron fluoride (BF{sub 2}{sup +}) implanted in crystalline and germanium amorphized silicon. Based on recently published models, the effect of fluorine on boron diffusion in silicon has been introduced and a modelling has been suggested. In order to simulate the boron experimental profiles, we have assumed that fluorine forms clusters involving interstitial boron which reduces the junction depth. Experimental results indicate that fluorine behaviour depends on amorphization energy. Moreover, even no germanium preamorphization is performed, silicon is still amorphized by fluorine species. Hence, BF{sub 2}{sup +} implantation leads to an amorphous/crystalline (a/c) interface near the surface. An improvement of published models is suggested taking into account fluorine effects. The simulations satisfactory reproduce the SIMS experimental profiles for a large scale of experimental conditions.
2002-01-01
Equation of state of laser-shocked compressed iron; Equation d'etat du fer comprime par choc laser
Energy Technology Data Exchange (ETDEWEB)
This thesis enters the field of highly compressed materials equation of state studies. In particular, it focuses on the case of laser shock compressed iron. This work indeed aims at getting to the conditions of the earth's core, comprising a solid inner core and a liquid outer core. The understanding of phenomena governing the core's thermodynamics and the geodynamic process requires the knowledge of iron melting line locus around the solid-liquid interface at 3.3 Mbar. Several experiments were performed to that extent. First, an absolute measurement of iron Hugoniot was obtained. Following is a study of partially released states of iron into a window material: lithium fluoride (LiF). This configuration enables direct access to compressed iron optical properties such as reflectivity and self-emission. Interface velocity measurement is dominated by compressed LiF optical properties and is used as a pressure gauge. Using a dual wavelength ...
2004-01-01
Electrometallurgical treatment of aluminum-matrix fuels
Energy Technology Data Exchange (ETDEWEB)
The electrometallurgical treatment process described in this paper builds on our experience in treating spent fuel from the Experimental Breeder Reactor (EBR-II). The work is also to some degree, a spin-off from applying electrometallurgical treatment to spent fuel from the Hanford single pass reactors (SPRs) and fuel and flush salt from the Molten Salt Reactor Experiment (MSRE) in treating EBR-II fuel, we recover the actinides from a uranium-zirconium fuel by electrorefining the uranium out of the chopped fuel. With SPR fuel, uranium is electrorefined out of the aluminum cladding. Both of these processes are conducted in a LiCl-KCl molten-salt electrolyte. In the case of the MSRE, which used a fluoride salt-based fuel, uranium in this salt is recovered through a series of electrochemical reductions. Recovering high-purity uranium from an aluminum-matrix fuel is more challenging than treating SPR or EBR-II fuel because the aluminum- matrix fuel is typically -90% ...
1996-08-01
Energy Technology Data Exchange (ETDEWEB)
Anode polarization measurement is performed in mixed solution of NaCl and NaF using SUS 304 steel to investigate whether F[sup -] promotes or inhibits pitting corrosion. Pitting corrosion does not occur in the solution of NaF only, but passive state is broken above a certain critical potential, resulting in overall dissolution. When anode polarization measurement is made in a solution of fixed concentration NaCl added with NaF, pitting corrosion is inhibited at a certain critical concentration. F[sup -] has no effect on corrosion potential in the solution up to this critical concentration. Overall dissolution occurs in the solution with higher concentration than the critical concentration, the current value at that time agrees with that in the solution of NaF alone, and no effect of Cl[sup -] is shown. The concentration range where pitting corrosion occurs and that where overall dissolution occurs are divided by a straight line when they are expressed by logarithm of NaCl and NaF ...
1994-05-15
Design of the heat receiver for the U.S./Russia solar dynamic power joint flight demonstration
Energy Technology Data Exchange (ETDEWEB)
A joint US/Russia program is being conducted to develop, fabricate, launch, and operate a solar dynamic demonstration system on Space Station Mir. The goal of the program is to demonstrate and confirm that solar dynamic power systems are viable for future space applications such as the International Space Station Alpha. The major components of the system include a heat receiver, a closed Brayton cycle power conversion unit, a power conditioning and control unit, a concentrator, a radiator, a thermal control system, and a Space Shuttle carrier. This paper discusses the design of the heat receiver component. The receiver comprises a cylindrical cavity, the walls of which are lined with a series of tubes running the length of the cavity. The engine working fluid, a mixture of xenon and helium, is heated by the concentrated sunlight incident on these tubes. The receiver incorporates integral thermal storage, using a eutectic mixture of lithium fluoride and calcium ...
1995-12-31
Coated semiconductor devices for neutron detection
Energy Technology Data Exchange (ETDEWEB)
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the coating thickness and electrical settings, ...
2002-01-01
International Nuclear Information System (INIS)
The radio, optical, x-ray and gamma-ray nebulae that surround many pulsars are thought to arise from synchrotron and inverse Compton emission. The energy powering this emission as well as the magnetic fields and relativistic particles are supplied by a 'wind' driven by the central object. The inner parts of the wind can be described using the equations of MHD, but these break down in the outer parts, when the density of charge carriers drops below a critical value. This paper reviews the wave properties of the inner part (striped wind), and uses a relativistic two-fluid model (cold electrons and positrons) to re-examine the nonlinear electromagnetic modes that propagate in the outer parts. It is shown that in a radial wind, two solutions exist for circularly polarized electromagnetic modes. At large distances one of them turns into a freely expanding flow containing a vacuum wave, whereas the other decelerates, corresponding to a confined flow.
2010-12-01
Two years of flight of the Pamela experiment: results and perspectives
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antinuclei with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, $15^{th}$ 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. In this work we describe the scientific objectives and the performance of PAMELA in its first two years of operation. Data on protons of trapped, secondary and galactic nature - as well as measurements of the December $13^{th}$ 2006 Solar Particle Event - are also provided.
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Rationale Receptor occupancy study has been performed to evaluate pharmacokinetic profiles in new antipsychotic drug development. While these findings highlight the value of positron emission tomography (PET) for dose-finding study, what is unclear is if it is necessary to conduct these studies in patients with schizophrenia or whether studies in healthy volunteers are adequate. Objectives To determine if it is necessary to conduct dopamine receptor occupancy studies in patients with schizophrenia or whether studies in healthy volunteers are adequate for dose-finding study, we compared the concentration?occupancy relationship in terms of EC50 between patients and healthy volunteers. Methods Ten healthy volunteers and eight patients with schizophrenia participated in the study. We measured ...
2011-01-01
The PAMELA space experiment: first year of operation
Energy Technology Data Exchange (ETDEWEB)
On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.
2008-05-15
British Library Electronic Table of Contents (United Kingdom)
Introduction.Microfluidic technology allows fast reactions in a simple experimental setup, while using very low volumes and amounts of starting material. Consequently, microfluidic technology is an ideal tool for radiolabeling reactions involving short-lived positron emitters. Optimization of the complex array of different reaction conditions requires knowledge of the different reaction parameters linked to the microfluidic system as well as their influence on the radiochemical yields. 1-(5-Deoxy-5-fluoro-?-d-arabinofuranosyl)-2-nitroimidazole ([18F]FAZA) is a frequently used radiotracer for PET imaging of tumor hypoxia. The present study describes the radiosynthesis of [18F]FAZA by means of microfluidic technology and subsequent small animal PET imaging in EMT-6 tumor-bearing mice.Methods...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The nitrogen content of 10 medicinal plant species has been determined by fast-neutron activation analysis (FNAA). Correction factors for the effects of the /sup 16/O(p,..cap alpha..)/sup 13/N knock-on proton-induced reaction and the (n,2n) reactions, which produce interfering positron-emitting radionuclides, have also been determined. The total relative interference from the /sup 16/O(p,..cap alpha..)/sup 13/N and (n,2n) reactions of K, Cl, Fe and Br was found to be 5.1 to 32.1% for the plant samples.
1983-05-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Many solute carrier transporters that interact with anticancer agents and contribute to their pharmacokinetics have been shown to be differentially upregulated in cancer cells as a result of adaptive response to altered nutritional requirements. This review focuses on pathophysiological function of membrane transporters responsible for the influx of physiological substances including oligopeptides, amino acids, and organic cations and anions, and summarizes the recent knowledge regarding mechanisms in their gene expressions. Broad substrate specificity of enhanced oligopeptide H+/peptide cotransporter 1 activity in cancer cells is useful for tumor tissue-specific delivery of chemotherapeutic agents and positron emission tomography diagnostic probes. Amino acid transporters such as...
2011-01-01
Semiclassical calculation of photon-stimulated Schwinger pair creation
International Nuclear Information System (INIS)
We consider the electron-positron pair creation by a photon in an external constant electric field. The presented treatment is based on a purely quasiclassical calculation of the imaginary part of the on-shell photon polarization operator. By using this approach we find the pair production rate for photons with polarization parallel as well as orthogonal to the external electric field in the leading order in the parameter eE/m"2, which has been recently found by other methods. For the orthogonal polarization we also find a new contribution to the rate, which is leading in the ratio of the photon energy to the electron mass #omega#/m. We also reproduce by a purely geometrical calculation the exponential factor in the probability of the stimulated pair creation at arbitrary energy of the photon.
2010-04-15
Secondary electron yield measurements from thin surface coatings for NLC electron cloud reduction
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
2004-01-01
International Nuclear Information System (INIS)
We have studied the features of formation and the possible stationary structures of a self-consistent magnetic field in a relativistic collisionless plasma, which are characteristic of a simple geometry of the Weibel instability that is well known in the nonrelativistic case. The universal condition is established, the growth rate is determined, and the criteria of saturation of the Weibel instability are analyzed for a broad class of anisotropic particle distribution functions (for definiteness, in application to an electron-positron plasma). A nonlinear equation of the Grad-Shafranov type describing the potential current structures is derived and its solutions are analytically studied. Special attention is paid to spatially harmonic, nonlinear current configurations with parameters determined by the properties of the initial homogeneous plasma subject to the Weibel instability. It is demonstrated that the magnetic field energy density in the obtained solutions ...
2008-12-01
British Library Electronic Table of Contents (United Kingdom)
Study Type - Therapy (case series)Level of Evidence 4 OBJECTIVE To present our experience of retroperitoneoscopic partial adrenalectomy (RPA) for small adrenal tumours, as with modern imaging methods small adrenal lesions are being diagnosed more commonly, and retroperitoneoscopic adrenal surgery for small adrenal tumours (PATIENTS AND METHODS We retrospectively reviewed the records of 389 consecutive retroperitoneoscopic adrenalectomies from September 2005 to December 2008, 88 of which were small adrenal tumours and treated by RPA. Ultrasonography and computed tomography (CT) were used in all patients before RPA, and magnetic resonance imaging or positron emission tomography/CT in some patients. We used RPA for adrenal tumours and total adrenalectomy for adrenal cancer. During the surgery...
2010-01-01
PET/MRI hybrid imaging: devices and initial results
British Library Electronic Table of Contents (United Kingdom)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
2008-01-01
PET and MRI in cardiac imaging: from validation studies to integrated applications
International Nuclear Information System (INIS)
Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance in cardiac applications together with the potential benefits ...
2009-03-01
Imaging pharmacodynamics in oncology. The potential significance of 'flares'
International Nuclear Information System (INIS)
The clinical use of "1"8F-fluorodeoxyglucose (FDG) positron emission tomography in monitoring anticancer treatment is expanding. At the same time a number of radiotracers aiming to image different aspects of tumour biology such as proliferation and apoptosis are being developed. However, the factors determining changes of radiotracer uptake parameters in response to treatment are not well understood. In many cases, cellularity may be the primary determinant of changes of FDG uptake and may confound the interpretation of metabolic changes. Early imaging assessments have in some cases showed transient increases of uptake parameters, commonly termed 'flares', which are likely to be unaffected by cellularity and directly reflect pharmacodynamics at a cellular level. In this review a number of settings where molecular imaging 'flares' have been described are discussed. Such changes may often be clinically informative and warrant careful study as potential predictive ...
2010-04-01
High energy photon-photon collisions
International Nuclear Information System (INIS)
The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, such as the scaling of the photon structure function, tt production, mini-jet ...
Gamma rays produced by inverse Compton scattering in the super-ACO storage ring free electron laser
International Nuclear Information System (INIS)
The inverse Compton scattering between positron bunches and the Free Electron Laser (FEL) of the SuperAco storage ring generates a collimated and tunable gamma-ray beam. The use of the FEL instead of a conventional laser, automatically provides the transverse alignment and synchronisation of the electron and optical beams. The Super-ACO FEL is operated in the 300-430 nm range at 800 MeV with a high repetition rate (8 MHz) and an average transmitted power of 300 mW at 350 nm. High energy gamma rays of 35 MeV are produced with a rate of 1.5 10 7 photons/second and good monocromaticity (about 10%). Applications of the SuperAco FEL installation for diamond irradiation and biological studies are envisaged. (author)
2000-06-05
First observation of psi(2S)-->K_S K_L
The decay psi(2S)-->K_S K_L is observed for the first time using psi(2S) data collected with the Beijing Spectrometer (BESII) at the Beijing Electron Positron Collider (BEPC); the branching ratio is determined to be B(psi(2S)-->K_S K_L) = (5.24\\pm 0.47 \\pm 0.48)\\times 10^{-5}. Compared with J/psi-->K_S K_L, the psi(2S) branching ratio is enhanced relative to the prediction of the perturbative QCD ``12%'' rule. The result, together with the branching ratios of psi(2S) decays to other pseudoscalar meson pairs (\\pi^+\\pi^- and K^+K^-), is used to investigate the relative phase between the three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.
2003-01-01
Fast Beam Intensity Measurements for the LHC
Particle accelerators are constructed and operated for a wide variety of applications. In particle physics - the branch of physics that studies the elementary constituents of matter and forces between them - high energy accelerators are used to look deep into the structure of matter. Medical particle accelerators are used for example in medicine to treat tumours [31], in imaging techniques such as Positron Emission Tomography (PET) [24], or for the radio-isotopes production. They also serve in many other industrial branches, e.g. geology, radiocarbon dating [39], molecular complex spectroscopy, lithography, food preservation etc. The eld of accelerator technology draws knowledge and expertise from a wide range of scientic disciplines and uses the latest technical knowledge. The incomplete list of covered disciplines includes mathematics, physics, electronics, computing, electromagnetic eld technology, microwave technology, cryogenics, vacuum technology, special ...
2010-01-01
Exclusive ?0 electroproduction on transversely polarized protons
International Nuclear Information System (INIS)
The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum of the quarks to the proton spin.
2009-08-17
Energy Technology Data Exchange (ETDEWEB)
The Advanced Photon Source injector synchrotron is a 7-GeV positron machine with a standard alternating gradient lattice. The calculated effect of dipole magnet strength errors on the orbit distortion, simulated by Monte Carlo, was reduced by sorting pairs of magnets having the closest simulated measured strengths to reduce the driving the term of the integer resonance nearest the operating point. This method resulted in a factor of four average reduction in the rms orbit distortion when all 68 magnets were sorted at once. The simulated effect of magnet measurement experimental resolution was found to limit the actual improvement. The {Beta}-beat factors were similarly reduced by sorting the quadrupole magnets according to their gradients.
1993-07-01
Energy Technology Data Exchange (ETDEWEB)
Existing oil reservoirs might be more fully exploited if the properties of the flow of oil and water in porous media were better known. In laboratory experiments it is important to collect as much information as possible to make a descriptive model of the system, including position imaging and chemical binding information. This thesis develops nuclear methods for obtaining position image and chemical binding information from flow experiments of porous media. A combined positron emission tomography and single photon emission computed tomography system to obtain position images, and a time-differential perturbed angular correlation system to obtain chemical binding information, have been built and thoroughly tested. 68 refs., 123 figs., 14 tabs.
1998-12-01
Design considerations for the magnetic system of a prototype x-ray free electron laser
Energy Technology Data Exchange (ETDEWEB)
A number of difficult technical challenges need to be solved in the fields of accelerator and free-electron laser (FEL) technologies in order to build an X-ray FEL. One of the tasks well suited to the Advanced Photon Source Low Energy Undulator Test Line (LEUTL) is to take the intermediate step of solving some of the problems of single-pass FEL operation in the ultraviolet range. The existing Advanced Photon Source (APS) linac, in addition to its role of supply positrons for the APS storage ring, will also be used to generate the particle beam for the LEUTL. Here, the design of the magnetic system for the high gain soft x-ray free electron laser is described.
1997-04-01
British Library Electronic Table of Contents (United Kingdom)
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
2009-01-01
Constraints on WIMP Dark Matter from the High Energy PAMELA $\\bar{p}/p$ data
A new calculation of the $\\bar{p}/p$ ratio in cosmic rays is compared to the recent PAMELA data. The good match up to 100 GeV allows to set constraints on exotic contributions from thermal WIMP dark matter candidates. We derive stringent limits on possible enhancements of the WIMP \\pbar flux: a $m_{\\rm WIMP}$=100 GeV (1 TeV) signal cannot be increased by more than a factor 6 (40) without overrunning PAMELA data. Annihilation through the $W^+W^-$ channel is also inspected and cross-checked with $e^+/(e^-+e^+)$ data. This scenario is strongly disfavored as it fails to simultaneously reproduce positron and antiproton measurements.
2008-01-01
Boron transient enhanced diffusion in heavily phosphorus doped silicon
International Nuclear Information System (INIS)
A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 x 10"1"4 cm"-"2, and then annealed at temperatures ranging from 700--1,000 C in a N_2 ambient for varying durations. As P doping concentration increased from 3 x 10"1"9 to 1 x 10"2"0 cm"-"3, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.
1996-12-02
The clinical application of positron emission tomography to colorectal cancer management
International Nuclear Information System (INIS)
Colerectal cancer (CRC) is the second commonest cancer in the Western World. Successful treatment relies significantly on accurate detection and staging of primary disease as well as the early identification of the presence and extent of recurrence. Morphological imaging techniques, particularly computed tomography (CT), are well established and widely available to carry out these tasks in addition to predicting and monitoring response to therapy. This review analyses the current inadequacies for imaging CRC and critically assesses the potential role of functional imaging with positron emission tomography (PET). It was reviewed the current literature, to use the experience from the firs 1000 PET studies carried out at the institution and the perspective of surgical colleagues. It was found little evidence for the use of 2-["1"8F]fluoro-2-deoxy-D-glucose (FDG)-PET for screening asymptomatic individuals and current modalities appear better suited for detection of ...
2001-09-01
The Next Linear Collider: NLC2001
Energy Technology Data Exchange (ETDEWEB)
Recent studies in elementary particle physics have made the need for an e{sup +}e{sup -} linear collider able to reach energies of 500 GeV and above with high luminosity more compelling than ever [1]. Observations and measurements completed in the last five years at the SLC (SLAC), LEP (CERN), and the Tevatron (FNAL) can be explained only by the existence of at least one particle or interaction that has not yet been directly observed in experiment. The Higgs boson of the Standard Model could be that particle. The data point strongly to a mass for the Higgs boson that is just beyond the reach of existing colliders. This brings great urgency and excitement to the potential for discovery at the upgraded Tevatron early in this decade, and almost assures that later experiments at the LHC will find new physics. But the next generation of experiments to be mounted by the world-wide particle physics community must not only find this new physics, they must find out what it is. These experiments ...
2002-01-14
Energy Technology Data Exchange (ETDEWEB)
In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the whole target volume. Therefore, in the ...
2005-12-21
International Nuclear Information System (INIS)
A post-irradiation annealing study was conducted with use of reactor pressure vessel(RPV) steel A533B C1.1 base metal irradiated to a dose of 4.84x10"1"8 n/cm"2 at about 380 deg C. Microhardness and positron annihilation (PA) methods were used to obtain better understanding of the recovery of radiation hardening. Isochronal anneal experiments indicated that two recovery processes occur during annealing of irradiated specimens. The first recovery process occurs in the temperature of 280-305 deg C. The variations of Ip, Iw and R parameters indicated that the formation of vacancy clusters by vacancy aggromeration and the annihilation parameters measured indicated that the dissolution of carbon atoms decorated around vacancy-type defects and possible precipitates, and the annihilation of monovacancies give rise to the second recovery process. It was further indicated that radiation anneal hardening (RAH) in the range of 305-405 deg C between the temperature ranges for ...
The magnetic spectrometer PAMELA for the study of cosmic antimatter in space
Energy Technology Data Exchange (ETDEWEB)
In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.
1995-09-01
The compact linear collider CLIC
A high luminosity (10e34 - 10e35 cm square/s) electron-positron Collider (CLIC) with a nominal centre-of-mass energy of 3 TeV has been under study for a number of years at CERN within an international collaboration of laboratories and institutes to provide the HEP community with a new accelerator-based facility for the post-LHC era. In order to achieve the very high design luminosity, very low emittance beams have to be produced and focused down to very small beam sizes at the interaction point. Beam acceleration using high frequency normal-conducting structures operating at high accelerating fields significantly reduces the length and, in consequence, the cost of the linac. The overall length of the 3 TeV collider is about 33 km. The goals of the CLIC scheme are ambitious, and require further R&D to demonstrate that they are indeed technically feasible. A new test facility is being built at CERN for this purpose with the aim to demonstrate the key feasibility ...
2004-01-01
The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The goal of this DOE-supported exhibition is to demystify Einstein`s formula E = mc{sup 2} by illustrating the interchangeability of matter (m) and energy (E), c{sup 2} being the exchange rate. The exhibition has two major parts, {open_quotes}matter into energy{close_quotes} and {open_quotes}energy into matter{close_quotes}, plus a video to connect them. {open_quotes}Matter into energy{close_quotes} has now been completed and has been placed on the museum floor. Positrons from a {sup 22}Na source are annihilated to produce gamma rays that are caught in NaI detectors. The viewer can alter the alignment of the detectors and observe the consequences for the rates of single and coincident counts. The viewer can also observe the effects of placing absorbers in front of the counters. Prototype explanatory graphics were placed around the exhibit and those will probably be changed after we have some experience with their effectiveness. The connecting video is in the ...
1995-08-01
The Bunch Injection Controller for the PEP-II Storage Rings
The PEP-II storage rings at SLAC each have 3492 'buckets' into which electrons and positrons can be injected into the high- and low-energy rings. Equipment to measure the currents of all the individual buckets was originally provided by the Lawrence Berkeley Laboratory and is implemented in VXI-based hardware. Data from this equipment as well as high precision direct current measurement provide the hard data for the Bunch Injection Controller. A large number of parameters determined by injection design considerations as well as set by operators for different circumstances are also used by the software algorithms to determine the desired bucket injection order and charge quantity for each injection pulse. These requests are then passed on to the venerable SLAC master pattern generator, which provides beams for other applications as well. This highly visible and highly successful system is implemented using the EPICS toolkit, and fits well into the merged SLAC ...
2001-01-01
Risks and safety aspects related to PET/MR examinations
International Nuclear Information System (INIS)
The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety standards do not take into ...
2009-03-01
International Nuclear Information System (INIS)
Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.
Energy Technology Data Exchange (ETDEWEB)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield ...
1984-08-01
International Nuclear Information System (INIS)
The radioiodine-labeled amines currently available as brain-imaging agents, based on our previous work and that of others, are prepared either by exchange labeling or by direct iodination of a protected intermediate. The intrinsic slowness of these processes limits their potential for use with the positron-emitting 122I, as it has a half-life of only 3.6 min. This isotope has advantages of a low dose to the patient and availability from a generator containing the parent 20-h 122Xe. To develop a radiopharmaceutical in which 122I could be utilized, we prepared a number of secondary and tertiary amines (maintaining the 2,5-dimethoxy substitution pattern which allows direct iodination at the 4-position) with 131I. The organ distributions of these compounds were studied, and the best properties were found in the N,N-dimethyl homologue (2,5-dimethoxy-N,N-dimethyl-4-iodoamphetamine). This compound was successfully synthesized in a matter of seconds, with a chemical yield ...
International Nuclear Information System (INIS)
The "6"2Zn-"6"2Cu generator system is one of the few which yield a pure positron emitting daughter. The authors have developed a method for the preparation of this generator system following 32 MeV #alpha# particle bombardment of nickel targets. The chemical processing involves two stages: first a hydrous zirconium oxide column is used at pH 4-5 to separate the zinc and copper activities produced in the target nickel, and secondly, a conventional anion exchange column is used to retain the "6"2Zn and remove all copper activities in 2M HCl. This column serves as the "6"2Cu generator which will yield pure "6"2Cu repeatedly, free from "6"2Zn and other impurities, in a mixture of HCl and NaCl. A method is outlined also to obtain a solution of "6"2Zn using the hydrous zirconium oxide (HZO) column. "6"1Cu can be prepared as a by-product in the above procedure, but a method for the preparation of "6"1Cu alone using an 18 MeV #alpha# particle beam on a nickel target and ...
Positron emission tomography for modelling of geochemical transport processes in clay
Energy Technology Data Exchange (ETDEWEB)
Geological clay formations are investigated for use as final underground deposit for heat producing nuclear waste. Special kinds of clay (e.g. bentonite) can also be used for the construction of geotechnical barriers. For the long time safety prognosis of the nuclear waste repositories the development of geochemical transport models is indispensable. The transport of aqueous solutions in clay is a complex process. The three-layer-minerals bentonite and illite swell by the adsorption of water, if the volume is restricted a high swelling pressure develops. The excellent barrier effect of natural clay formations and geotechnical clay barriers is based on the high swelling pressure and the high adsorption capacity for radionuclides and other pollutants. The two-layer-mineral kaolinite has no swelling capacity. In contrast to sandy layers a special geochemical transport potential exists in clay besides the well known matrix potential which influences essentially the transport process. ...
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)
2005-10-15
PET/MRI hybrid imaging: devices and initial results
International Nuclear Information System (INIS)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI systems have shown ...
2008-06-01
Observability of complex ghosts and tachyons
International Nuclear Information System (INIS)
The complex ghost introduced previously by the present author is studied from a standpoint whether its effects are observable by experiments or not. According to the theory of complex ghost the scattering cross section of two real particles shows some particular properties. It has a kind of resonance peak at a certain energy which does not conform to the Breit-Wigner formula. It has also a peak for a certain energy transfer, if there exist tachyons. The tachyon is a kind of ghost and is allowed to exist in the theory. Using these properties the complex ghosts are expected to be detected by experiments. The recently observed resonance psi(3.1) is supposed to be the complex ghost of photon, since they have the same quantum numbers. If it is assumed, some properties of the resonance known by experiments are explained naturally to a certain extent. Along the same line it is not unnatural to expect that the photon is also accompanied by a tachyon as a ghost. An experiment to detect the ...
British Library Electronic Table of Contents (United Kingdom)
Combination agents comprising two different pharmacophores with the same biological target have the potential to show additive or synergistic activity. Bis(thiosemicarbazonato)copper(II) complexes (e.g. 64Cu-ATSM) and nitroimidazoles (e.g. 18F-MISO) are classes of tracer used for the delineation of tumor hypoxia by positron emission tomography (PET). Three nitroimidazole-bis(thiosemicarbazonato)copper(II) conjugates were produced in order to investigate their potential as combination hypoxia imaging agents. Two were derived from the known bifunctional bis(thiosemicarbazone) H2ATSM/A and the third from the new precursor diacetyl-2-(4-N-methyl-3-thiosemicarbazone)-3-(4-N-ethylamino-3-thiosem icarbazone) - H2ATSM/en. Oxygen-dependent uptake studies were performed using the 64Cu radiolabelled ...
2010-01-01
Light Sterile Neutrino Effects at theta_13-Sensitive Reactor Neutrino Experiments
We study the impact of very light sterile neutrinos (Delta m^2_new around 1 to 10 times 10^(-2) eV^2, sin^2 2theta_new<10^(-1)) on upcoming theta_13-driven reactor antineutrino experiments like Double-CHOOZ and Daya Bay. Oscillations driven by these vales of Delta m^2_new affect data in the near and far detectors differently and hence potentially modify the capability of these experimental setups to constrain and measure sin^2 2theta_13. We find that the hypothesis theta_new different from zero negatively impacts one's ability to either place an upper bound on sin^2 2theta_13 in the advent of no oscillation signal or measure sin^2 2theta_13 if a theta_13-driven signal is observed. The impact of sterile neutrino effects, however, depends significantly on one's ability to measure the recoil positron energy spectrum. If sin^2 2theta_new is larger than 10^(-2), upcoming theta_13-driven reactor antineutrino experiments should be able to measure sin^2 2theta_new and ...
2008-01-01
Launch of the Space experiment PAMELA
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger mode the ...
2007-01-01
International Nuclear Information System (INIS)
Fe-Cu binary alloys are often used to mimic the behaviour of reactor pressure vessel steels. Their study allows identifying some of the defects responsible for irradiation-induced hardening. But recently the influence of manganese and nickel in low-Cu steels has been found to be important as well. In contrast with existing models found in the literature, which predict that hardening saturates after a certain dose, Fe alloys containing nickel and manganese irradiated in a material test reactor (BR2) show a continuous increase of hardening, up to doses equivalent to about 40 years of operation. Considerations based on positron annihilation spectroscopy analyses suggest that the main objects causing hardening in Cu-free alloys are most probably self-interstitial clusters decorated with manganese. In low-Cu reactor pressure vessel steels and in Fe-CuMnNi alloys, the main effect is still due to Cu-rich precipitates at low doses, but the role of manganese-related ...
2008-09-01
Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT
International Nuclear Information System (INIS)
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using X-ray CT. This idea was derived from our observations in ...
1986-01-01
International Nuclear Information System (INIS)
Premature fusion of multiple cranial sutures has been associated with increased intracranial pressure and the potential for mental impairment. Isolated craniosynostosis, however, is considered a benign condition primarily reconstructed for aesthetic purposes. A comparative analysis, to assess the differences between pre- and post operatory cerebral perfusion of patients who underwent surgery for simple cranisynostosis, was performed using single positron emission computed tomography ''SPECT'' Images. Cerebral blood flow studies were performed using "9"9"mTc-HMPAO SPECT in children with simple cranisynotoses. The subjects were 8 children with craniosynostosis (age, 2 months-9 years). Preoperative revealed regional hypovascularity in the cerebral hemisphere in 5 cases (62%). In 6 patients the cerebral blood flow normalized or increased after craniofacial reconstruction. We demonstrated the presence of regional hypovascularity in the cerebral hemisphere of simple ...
1998-09-01
Design and implementation of the BESIII detector-control system
Energy Technology Data Exchange (ETDEWEB)
In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has been developed for the LCL. Network communication and web server ...
2008-07-21
Damping the. pi. -mode instability in the SLC damping rings with a passive cavity
Energy Technology Data Exchange (ETDEWEB)
Operating the Stanford Linear Collider (SLC) at 120Hz repetition rate requires the presence of two bunches in both the electron and the positron damping ring. The {pi}-mode instability, a coupled bunch instability where the two bunches oscillate with a phase difference of 180{degrees}, had been observed in both rings with low current thresholds of 7{sup *}10{sup 9} particles per bunch. To avoid the instability, the RF system had to be operated in ways which in general reduced the cavity gap voltages and required constant operational attention. For the 1992 running cycle a passive cavity was installed and successfully tested. It is tuned to the frequency of the lower synchrotron oscillation sideband of an odd revolution harmonic. The impedance of the cavity then damps {pi}-mode oscillations very similar to the Robinson damping provided by the main RF cavities which damps O-mode synchrotron oscillations. In this report we describe the motivation and physical ...
1992-07-01
Damping the {pi}-mode instability in the SLC damping rings with a passive cavity
Energy Technology Data Exchange (ETDEWEB)
Operating the Stanford Linear Collider (SLC) at 120Hz repetition rate requires the presence of two bunches in both the electron and the positron damping ring. The {pi}-mode instability, a coupled bunch instability where the two bunches oscillate with a phase difference of 180{degrees}, had been observed in both rings with low current thresholds of 7{sup *}10{sup 9} particles per bunch. To avoid the instability, the RF system had to be operated in ways which in general reduced the cavity gap voltages and required constant operational attention. For the 1992 running cycle a passive cavity was installed and successfully tested. It is tuned to the frequency of the lower synchrotron oscillation sideband of an odd revolution harmonic. The impedance of the cavity then damps {pi}-mode oscillations very similar to the Robinson damping provided by the main RF cavities which damps O-mode synchrotron oscillations. In this report we describe the motivation and physical ...
1992-07-01
Combining anatomy and function: the path to true image fusion
Energy Technology Data Exchange (ETDEWEB)
Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted in a single gantry. The use of existing scanner technology ensures that no compromises are made in the clinical efficacy of either the anatomical or functional imaging ...
2001-10-01
Boron transient enhanced diffusion in heavily phosphorus doped silicon
Energy Technology Data Exchange (ETDEWEB)
A study has been made of B transient enhanced diffusion (TED) in heavily P-doped Si using secondary ion mass spectroscopy (SIMS) and positron annihilation spectroscopy (PAS). The P-doped silicon was implanted with boron ions of 40 keV energy to a dose of 3 {times} 10{sup 14} cm{sup {minus}2}, and then annealed at temperatures ranging from 700--1,000 C in a N{sub 2} ambient for varying durations. As P doping concentration increased from 3 {times} 10{sup 19} to 1 {times} 10{sup 20} cm{sup {minus}3}, boron diffusivity and the immobile boron fraction decreased. The experimental results are inconsistent with the predictions of the Fermi-level model and suggest that the clustering between B atoms and Si interstitials should be invoked in order to explain the immobile portion of the B peak during TED.
1997-11-01
BDTPS The BNCT Treatment Planning System jointly developed at DIMNP and JRC/IE
The idea to couple the Treatment Planning System (TPS) to the information on the real boron distribution in the patient is the main added value of the new methodology set-up at DIMNP of University of Pisa, in collaboration with the JRC of Petten (NL). The methodology has been implemented in the new TPS, called BDTPS (Boron Distribution Treatment Planning System), which takes into account the actual boron distribution in the patient brain, while the standard TPS assumes a uniform boron distribution, absolutely far from the reality. Nowadays, Positron Emission Tomography (PET) is able to provide this in vivo information. The new TPS, based on the Monte Carlo technique, has been validated comparing the main BNCT parameters (thermal flux, boron dose, etc.) as measured during the irradiation of a special heterogeneous boron phantom (HEBOM), ad hoc designed, as calculated by the BDTPS and by the standard TPS SERA. An evident SERA overestimation of the thermal neutron ...
2003-01-01
International Nuclear Information System (INIS)
As researchers explore new applications for positron emission tomography radiopharmaceuticals, the demand for effective and readily available radiopharmaceuticals continues to increase. The syntheses of two such radiopharmaceuticals, ["1"1C]acetate and ["1"1C]palmitate, can be automated on the GE Tracerlab FX_C_-_P_r_o by utilizing Grignard reactions. Radiochemical purities of the ["1"1C]acetate and the ["1"1C]palmitate products were high (>98% and >99.9%, respectively) with average non-corrected yields of 18% (n=3) and 10% (n=5), respectively. These data comprise the validation trials for site qualification of clinical production of both radiopharmaceuticals. -- Graphical abstract: Automated syntheses of ["1"1C]acetate and ["1"1C]palmitate using a modified GE Tracerlab FX_C_-_P_r_o are reported. Radiochemical purities of the ["1"1C]acetate and the ["1"1C]palmitate products were high (>98% and >99.9%, respectively) with average non-corrected yields of ...
2011-04-01
Assessment of PET and MRI Polar Map using Gaussian Mixture Model
International Nuclear Information System (INIS)
Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using PET and ...
2010-10-01
Application of conventional laser technology to gamma-gamma colliders
International Nuclear Information System (INIS)
A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns about the survivability of mirrors located ...
1994-03-28
Application of conventional laser technology to gamma-gamma colliders
Energy Technology Data Exchange (ETDEWEB)
A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address concerns about the survivability of ...
1995-02-01
Application of conventional laser technology to gamma-gamma colliders
Energy Technology Data Exchange (ETDEWEB)
A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
A beta microprobe was successfully applied to monitor arterial input function for quantification of regional cerebral blood flow (rCBF) in the monkey brain with {sup 15}O-water and positron emission tomography (PET). The sensitivity of the probe was approximately 0.83 to 1.67 cps/kBq/ml depending on the studies. A preliminary study was performed to find a suitable use and to evaluate the performance of the system and data analysis procedure. The results showed that dispersion correction of measured input function was unnecessary if microprobes were connected directly to the arterial catheter. Then multiple CBF measurements were done in three monkeys under anesthesia. Identical regions of interest were placed with the aid of magnetic resonance imaging (MRI) of each monkey and rCBF values were estimated. Estimated rCBFs were reproducible for several measurements. The mean CBF value for a pentobarbital anesthetized monkey was 46.0 ml/min/100 g (PaCO{sub 2}=46.3 mmHg). ...
1998-02-01
A look ahead: PET/MR versus PET/CT
Energy Technology Data Exchange (ETDEWEB)
Integration of positron emission tomography (PET) and magnetic resonance (MR) has become a topic of increasing interest to the imaging community over the past two years. In this text, the authors attempt to distinguish facts from fiction concerning such integrated systems. Analysis of existing information of combined imaging on existing brain PET/MR systems and imaging experience with PET-computed tomography (CT) is reviewed. Various types of system integration of PET and MR are discussed with completely independent systems on one hand and completely integrated systems with the possibility of simultaneous data acquisition on the other hand. Furthermore, it is discussed, what simultaneous data acquisition with nuclear imaging systems combined with MR or CT really means, as technical simultaneity may not be relevant in light of the pharmacokinetics of the nuclear tracers used. The authors conclude that combining PET/MR is an interesting research endeavor with ...
2009-03-15
A New Measurement of Kaonic Hydrogen X rays
The $\\bar{K}N$ system at threshold is a sensitive testing ground for low energy QCD, especially for the explicit chiral symmetry breaking. Therefore, we have measured the $K$-series x rays of kaonic hydrogen atoms at the DA$\\Phi$NE electron-positron collider of Laboratori Nazionali di Frascati, and have determined the most precise values of the strong-interaction energy-level shift and width of the $1s$ atomic state. As x-ray detectors, we used large-area silicon drift detectors having excellent energy and timing resolution, which were developed especially for the SIDDHARTA experiment. The shift and width were determined to be $\\epsilon_{1s} = -283 \\pm 36 \\pm 6 {(syst)}$ eV and $\\Gamma_{1s} = 541 \\pm 89 {(stat)} \\pm 22 {(syst)}$ eV, respectively. The new values will provide vital constraints on the theoretical description of the low-energy $\\bar{K}N$ interaction.
2011-01-01
2001 Report on the Next Linear Collider
Energy Technology Data Exchange (ETDEWEB)
Recent studies in elementary particle physics have made the need for an e{sup +}e{sup -} linear collider able to reach energies of 500 GeV and above with high luminosity more compelling than ever [1]. Observations and measurements completed in the last five years at the SLC (SLAC), LEP (CERN), and the Tevatron (FNAL) can be explained only by the existence of at least one particle or interaction that has not yet been directly observed in experiment. The Higgs boson of the Standard Model could be that particle. The data point strongly to a mass for the Higgs boson that is just beyond the reach of existing colliders. This brings great urgency and excitement to the potential for discovery at the upgraded Tevatron early in this decade, and almost assures that later experiments at the LHC will find new physics. But the next generation of experiments to be mounted by the world-wide particle physics community must not only find this new physics, they must find out what it is. These experiments ...
2001-08-28
International Nuclear Information System (INIS)
To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid tumors criteria. Response on PET-CT was ...
International Nuclear Information System (INIS)
Non-traumatic osteonecrosis of the femoral head (ONF) is considered to be a disease that occurs primarily due to ischemia of the femoral head, while its etiology and pathology are not fully understood. It is therefore necessary to identify the characteristics of the hemodynamics of the femoral head. In this study, the hemodynamics in the ilium and proximal regions of the femur, including the femoral head, was investigated using positron emission tomography (PET). The subjects of this study consisted of 8 hip joints of four healthy male adults and 3 hip joints on the contralateral side of a femoral neck fracture, avulsion fracture of the greater trochanter and coxarthrosis (1 case each, all females) for a total of 11 hip joints of 7 subjects. The ages of the subjects ranged from 25 to 87 years (average age: 54 years). Blood flow was measured by means of the H_2"1"5O dynamic study method and blood volume was measured by means of the "1"5O-labeled carbon monoxide ...
2005-10-01
Energy Technology Data Exchange (ETDEWEB)
The Institute of Energetic and Nuclear Research - IPEN is a research and development institution, located in a densely populated area, in the city of Sao Paulo. The nuclear fuel cycle was developed from the Yellow Cake to the enrichment and reconversion at IPEN. After this phase, all the technology was transferred to private enterprises and to the Brazilian Navy (CTM/SP). Some plants of the fuel cycle were at semi-industrial level, with a production over 20 kg/h. As a research institute, IPEN accomplished its function of the fuel cycle, developing and transferring technology. With the necessity of space for the implementation of new projects, the uranium hexafluoride (UF{sub 6}) production plant was chosen, since it had been idle for many years and presented potential leaking risks, which could cause environmental aggression and serious accidents. This plant decommission required accurate planning, as this work had not been carried out in Brazil before, for this type of facility, and ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The corrosion behaviour of the stainless steels 304, 316 Ti, 25Cr-20Ni-Mo-Ti, nickel base alloys Hastelloy C4, Inconel 625, Incoloy 800, Ti and Ti-0.2% Pd alloy has been studied in the aerated or deaerated solutions at 20/sup 0/C and 90/sup 0/C whose compositions are representative of interstitial ground waters: granitic or clay waters or salt brine. The electrochemical techniques used are voltametry, polarization resistance and complexe impedance measurements. Electrochemical data show the respective influence of the parameters such as temperature, solution composition and dissolved oxygen, addition of soluble species chloride, fluoride, sulfide and carbonates, on which depend the corrosion current density, the passivation and the pitting potential. The inhibition efficiency of carbonate and bicarbonate activities against pitting corrosion is determined. In clay water at 90/sup 0/C, Ti and Ti-Pd show very high passivation aptitude and a broad passive potential ...
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
Many thermoluminescent materials has been developed and used for photon personal dosimetry but no one has all desired characteristics alone. These characteristics include robustness, high sensitivity, energy photon independence, large range of photon energy detection, good reproducibility, small fading and simple glow curve with peaks above 150 deg C. Calcium Sulfate Dysprosium doped (CaSO{sub 4}:Dy) phosphor Thermoluminescent Dosimeter (TLD) has been used by many laboratories, mainly in Brazil and India. Another interesting phosphor is Calcium Fluoride (CaF{sub 2}). These phosphor advantages begin to be more required and its disadvantages have became more apparent, in a global market more and more competitive. These phosphors are used in environmental and area monitoring, once they present more sensibility than other phosphors, like LiF:Mg. Theirs mainly disadvantage is a strong energetic dependence response, which must be corrected for theirs application in the ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA facility, an unreflected cylindrical tank (56 cm diam), was partially filled with ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
The kinetics of the oxidative addition of CH/sub 3/I to platinum(II) complexes in aqueous solutions of K/sub 2/PtCl/sub 4/ and KPtCl/sub 3/(C/sub 2/H/sub 4/) have been studied by PMR and GLC. The second-order rate constants for the PtCl/sub 3/(H/sub 2/O)/sup -/ and PtCl/sub 4//sup 2 -/ particles are equal to 400 exp(-2.7 x 10/sup 3//T) and 3.18 x 10/sup 10/ exp(-9.2 x 10/sup 3//T) mole/sup -1/ x liter x sec/sup -1/, respectively. The introduction of a ..pi..-acceptor ligand, viz. ethylene, into the coordination sphere of platinum(II) results in a sharp drop in the rate, probably due to a decrease in the electron density on the platinum atom. According to the PMR data, the product of the oxidative addition of CH/sub 3/I to Zeise's salt is a methyl complex of platinum(IV), is identical to the complex obtained by reacting methyl iodide with K/sub 2/PtCL/sub 4/, and does not contain an olefin.
1987-05-01
Electron-beam-plasma ion source as source of negative fluorine
Energy Technology Data Exchange (ETDEWEB)
Radioactive ion beams (RIBs) of short-lived isotopes of fluorine are in demand for investigating astrophysical phenomena related to the hot CNO cycle and rp processes responsible for stellar nucleosynthesis. Since negative ion beams are required for injection into tandem electrostatic accelerators, such as the 25 MV tandem accelerator used for post acceleration of RIBs for the Holifield Radioactive Ion Beam Facility (HRIBF) research program at the Oak Ridge National Laboratory (ORNL), efficient, direct-formation F{sup -} ion sources are highly desirable for RIB applications involving this type of post-accelerator. We have conceived and evaluated a direct extraction F{sup -} source for potential RIB applications which is predicated on the reverse polarity operation of a positive electron-beam-plasma target/ion source (EBPTIS) while simultaneously feeding fluorine rich compounds and Cs vapor into the source. The source is found to operate in two separately distinct temperature regimes ...
1997-11-01
Co-operative downconversion luminescence in Tm3+/Yb3+ : SiO2-Al2O3-LiF-GdF3 glasses
International Nuclear Information System (INIS)
Oxyfluoride aluminosilicate glasses in the composition of 50SiO2-20Al2O3-20LiF-10GdF3-0.5TmF3-xYbF3 (x = 0, 1.0, 2.5, 5, 7.5, 10, 15, 20, 25 and 30 mol%) have been prepared to study their thermal and optical properties. From the differential thermal analysis measurements, glass transition temperatures and onset crystallization temperatures have been evaluated and from them glass stability factors were calculated. Glass stabilities decreased gradually with fluoride content increment in all the studied glasses. The photoluminescence and decay measurements have also been carried out for all these glasses. In these glasses, an efficient near infrared quantum cutting with optimal quantum efficiency approaching 187% has been demonstrated, by exploring the co-operative downconversion mechanism from Tm3+ to Yb3+, with 467 nm (Tm3+ : 3H6 ? 1G4) excitation wavelength. These glasses are promising materials to achieve high efficiency silicon based solar cells by means of ...
2008-09-07
Case report: Denys- Drash syndrome.
BACKGROUND: Denys-Drash Syndrome (DDS) is an uncommon disorder that appears sporadically and in rare cases may be inherited as an autosomal dominant trait It manifests either at birth or within the first year of life and typically consists of the triad of congenital nephropathy, Wilms tumour and intersex disorder. CASE REPORT: A 10 year-old Caucasian girl was referred to the Dental Department, at Glasgow Royal Hospital for Sick Children by her Paediatric Nephrologist Consultant. The patient was being teased by her peers over her markedly discoloured teeth. The dental history revealed that the patient was a regular dental attendee from an early age. She was dentally anxious having only experienced dental treatment under general anaesthesia (GA) when she was 4 years old. Apparently her primary dentition also showed a generalised discolouration. TREATMENT: This consisted of multiple visits for diet analysis and tooth brushing instruction with the use of disclosing tablets. Plaque control ...
2007-12-01
Air quality monitoring report for Alberta, 1991
Energy Technology Data Exchange (ETDEWEB)
In 1991, the air quality monitoring program in Alberta consisted of continuous, intermittent, static, portable, mobile, and acid precipitation monitoring networks. The air quality monitoring networks are described and results from the continuous, intermittent, static, and acid precipitation networks are summarized. Regulations and guidelines for individual pollutants are discussed in detail. Pollutants monitored continuously (1-h average basis) include ammonia, CO, coefficient of haze, H{sub 2}S, nitrogen oxides, ozone, SO{sub 2}, and total hydrocarbons. Good air quality was observed most of the time at all continuous monitoring stations in 1991. The frequency of good air quality ratings ranged from 81% at the Edmonton northwest station to 98% at the Fort McMurray station. Intermittent monitoring (every 6th day) was conducted for total suspended particulates and for vinyl chloride monomers in the Fort Saskatchewan area. Chemical analyses of benzo(a)pyrene and lead were performed on ...
1993-08-01
Energy Technology Data Exchange (ETDEWEB)
In this work, we perform spectroscopic studies to characterize the energy transfer processes occurring in rare-earth doped lithium fluoride systems, aiming the optimization of the population inversion of these media. Yb{sup 3+} ion was used in order to probe the electron-phonon coupling in LiYF{sub 4}, LiGdF{sub 4} and LiLuF{sub 4} matrices. In these systems it was obtained the average phononenergy, the vibronic transition probability and Huang-Rhys coupling constant. These parameters are dependent on the crystal host and the LiLuF{sub 4} system presents excluded correlation effects, an electronic repulsion that weakens the vibronic coupling. The Tm:Ho:LiYF{sub 4} system was studied under diode laser pumping at 796 nm, aiming the 2 {mu}m emission optimization. The ideal conditions of concentration and laser power were determined favouring the latter emission. Upconversion processes of two photons were identified besides the energy transfer among ions. The dynamic ...
2001-07-01
Usefulness of "1"8F-FDG PET in intrahepatic cholangiocarcinoma
International Nuclear Information System (INIS)
Surgical resection is the only curative treatment strategy for intrahepatic cholangiocarcinoma (CC). Therefore, accurate staging is essential for appropriate management of patients with CC. We assessed the usefulness of 2-["1"8F]fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the staging of CC. We undertook a retrospective review of FDG PET images in 21 patients (10 female, 11 male; mean age 57 years) diagnosed with CC. Ten patients had hilar CC and 11, peripheral CC. Patients underwent abdominal magnetic resonance imaging (MRI) (n=20) and computed tomography (CT) (n=12) for the evaluation of primary tumours, and chest radiography and whole-body bone scintigraphy for work-up of distant metastases. For semi-quantitative analysis, the maximum voxel standardised uptake value (SUV_m_a_x) was obtained from the primary tumour. All peripheral CCs showed intensely increased FDG uptake, and some demonstrated ring-shaped uptake corresponding to ...
2003-11-01
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
International Nuclear Information System (INIS)
Positron emission tomography (PET) is a fully quantitative technology for imaging metabolic pathways and dynamic processes in vivo. Attenuation correction of raw PET data is a prerequisite for quantification and is typically based on separate transmission measurements. In PET/CT attenuation correction, however, is performed routinely based on the available CT transmission data. Recently, combined PET/magnetic resonance (MR) has been proposed as a viable alternative to PET/CT. Current concepts of PET/MRI do not include CT-like transmission sources and, therefore, alternative methods of PET attenuation correction must be found. This article reviews existing approaches to MR-based attenuation correction (MR-AC). Most groups have proposed MR-AC algorithms for brain PET studies and more recently also for torso PET/MR imaging. Most MR-AC strategies require the use of complementary MR and transmission images, or morphology templates generated from transmission images. We ...
2009-03-01
The influence of different chemical elements in the hardening/embrittlement of RPV steels
International Nuclear Information System (INIS)
The hardening and embrittlement of reactor pressure vessel (RPV) steels is of great concern in the actual nuclear power plant life assessment. This embrittlement is caused by irradiation-induced damage, like vacancies, interstitials, solutes and their clusters. The current procedure to estimate material properties for the irradiated pressure vessels is based on Charpy-V tests of identical material located at the inner shell of the reactor. But the reason for the embrittlement of the materials is not yet totally known. The real nature of the irradiation damage should thus be examined as well as its evolution in time. Fe-Cu binary alloys are often used to mimic the behaviour of such steels. Their study allows. Identifying some of the defects responsible of the hardening, especially when compared to pure iron or C-micro-alloyed iron. More recently the influence of manganese and nickel in low-Cu RPV steels has become a significant topic. Thus in contrast with the existing models in the ...
2007-06-04
The Advanced Photon Source injection timing system
Energy Technology Data Exchange (ETDEWEB)
The Advanced Photon Source consists of five accelerators. The injection timing system provides the signals required to cause a bunch emitted from the electron gun to navigate through intermediate accelerators to a specific bucket (1 out of 1296) within the storage ring. Two linacs and a positron accumulator ring operate at 60Hz while a booster synchrotron ramps and injects into the storage ring at 2Hz. The distributed, modular VME/VXI-based injection timing system is controlled by two EPICS-based input/output controllers (IOCs). Over 40 VME/VXI cards have been developed to implement the system. Card types range from 352MHz VXI timing modules to VME-based fiber optic fanouts and logic translators/drivers. All timing is distributed with fiber optics. Timing references are derived directly from machine low-level rf of 9.77MHz and 352MHz. The timing references provide triggers to programmable delay generators. Three grades of timing are provided. Precision timing is ...
1995-12-31
Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil
International Nuclear Information System (INIS)
The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity accumulated in the cortex ...
1995-07-01
Resolution studies of a GEM-based TPC
Energy Technology Data Exchange (ETDEWEB)
Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy between 1 GeV and 6 GeV. Using the independent measurement of the hodoscope allows systematic studies of ...
2006-12-15
International Nuclear Information System (INIS)
Radioimmunotherapy (RIT) is a new treatment option for patients with non-Hodgkin lymphoma (NHL). Response to RIT currently remains difficult to predict using conventional prognostic factors and could be refined using functional imaging. The goal of this work is to evaluate the value of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in predicting response to Yttrium 90-labeled monoclonal antibodies for patients with NHL. Thirty-five patients with NHL who had undergone 18F-FDG PET prior to RIT with either 90Y-ibritumomab tiuxetan (group A; n=17) or 90Y-epratuzumab tetraxetan (group B; n=18) were included in this retrospective study. Four functional criteria were determined for each tumour lesion in a given patient: maximum and mean standard uptake values (SUVmax and SUVmean), functional lesion volume (LVol) and total lesion glycolysis (TLG, product of the volume and the SUVmean). For each patient, we determined highest SUVmax and SUVmean, cumulative ...
2010-03-01
International Nuclear Information System (INIS)
Purpose: Efficacy and safety of the own single-center experience with moderately dosed radiosurgery (SRS) for limited (one to four) brain metastases were analyzed and correlated with patient- and treatment-related variables. Patients and Methods: Between 05/1998 and 10/2006, 93 patients received SRS for a total of 142 brain metastases. The median number of brain metastases treated per patient was one (range, one to four). 46 patients (49%) received initial SRS alone, 13 patients (14%) SRS with up-front whole-brain radiotherapy (WBRT), and 34 patients (37%) SRS for recurrent metastases after WBRT. Median dose was 16 Gy (range, 10-20 Gy). Results: Median overall survival (OS) was 7.5 months. The actuarial 6- and 12-month data for OS were 60% and 35%, for local brain control (LBC) 87% and 79%, and for distant brain control (DBC) 48% and 37%, respectively. Only ten of 46 patients (22%) with initial SRS alone ultimately received WBRT. Ten patients suffered from seizures within 3 months ...
2010-02-01
Origin of {gamma}-rays from young open clusters
Energy Technology Data Exchange (ETDEWEB)
The young open cluster Berkeley 87 was predicted to be associated with the COS B {gamma}-ray source 2CG 075+00 on the basis of the experimental evidence of the presence of a shock front around the Wolf - Rayet star ST3 placed in the inner part of the cluster. The CGRO phase-1 data confirm this identification. Protons accelerated at the shock boundary can produce {pi} deg. via p-p interactions and then {gamma}-rays. With the measured flux F{sub {gamma}} (E > 100 MeV) {approx_equal} 9x10{sup -7} ph cm{sup -2} s{sup -1} and the power-law proton spectrum with spectral index {gamma} = 2, the cosmic-ray-energy-density in the inner part ({approx} 0.8 pc radius) of Berk 87 is about 100 times greater than that in the vicinity of the Earth. We have calculated {gamma}-ray spectra expected from the decay of {pi}{sup d}eg. produced in p-p interactions. The spectra have been normalized to the observed flux of Berk 87 by using different input proton spectra. The comparison of these normalized ...
1996-08-01
Nucleosynthesis in the Hot Convective Bubble in Core-Collapse Supernovae
Energy Technology Data Exchange (ETDEWEB)
As an explosion develops in the collapsed core of a massive star, neutrino emission drives convection in a hot bubble of radiation, nucleons, and pairs just outside a proto-neutron star. Shortly thereafter, neutrinos drive a wind-like outflow from the neutron star. In both the convective bubble and the early wind, weak interactions temporarily cause a proton excess (Y{sub e} {approx}> 0.50) to develop in the ejected matter. This situation lasts for at least the first second, and the approximately 0.05-0.1 M{sub {circle_dot}} that is ejected has an unusual composition that may be important for nucleosynthesis. Using tracer particles to follow the conditions in a two-dimensional model of a successful supernova explosion calculated by Janka, Buras, and Rampp (2003), they determine the composition of this material. most of it is helium and {sup 56}Ni. The rest is relatively rare species produced by the decay of proton-rich isotopes unstable to positron emission. ...
2004-09-02
DEFF Research Database (Denmark)
The coupling between cerebral metabolic rate of oxygen (CMRO2) and blood flow (CBF) in response to visual stimulation was evaluated by means of a model of oxygen delivery. The model predicted a nonlinear relationship between stimulus-evoked changes of oxygen consumption and blood flow. The magnitude of the CMRO2/CBF ratio index (IO2) was used to indicate the degree of flow-metabolism coupling prevailing in specific areas of the brain during physiological stimulation. Therefore, the index provided a measure of the blood oxygenation level dependent (BOLD) magnetic resonance contrast. To evaluate the changes of IO2 in response to visual stimulation, the model was applied to the effect of a changing flicker rate of a visual stimulus on the magnitudes of CBF, CMRO2, and oxygen diffusion capacity, in the human brain. Positron emission tomography (PET) was used to measure the CBF and the CMRO2 in 12 healthy volunteers who viewed a cross-hair (baseline) or a yellow-blue ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
(3H)Cyclofoxy (CF: 17-cyclopropylmethyl-3,14-dihydroxy-4,5-alpha-epoxy-6-beta-fluoromorp hinan) is an opioid antagonist with affinity to both mu and kappa subtypes that was synthesized for quantitative evaluation of opioid receptor binding in vivo. Two sets of experiments in rats were analyzed. The first involved determining the metabolite-corrected blood concentration and tissue distribution of CF in brain 1 to 60 min after i.v. bolus injection. The second involved measuring brain washout for 15 to 120 s following intracarotid artery injection of CF. A physiologically based model and a classical compartmental pharmacokinetic model were compared. The models included different assumptions for transport across the blood-brain barrier (BBB); estimates of nonspecific tissue binding and specific binding to a single opiate receptor site were found to be essentially the same with both models. The nonspecific binding equilibrium constant varied modestly in different brain structures (Keq = ...
1991-03-01
Introducing DeBRa: a detailed breast model for radiological studies
Energy Technology Data Exchange (ETDEWEB)
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the Cooper ligaments and the ...
2009-07-21
International Nuclear Information System (INIS)
Introduction: Development of agonist positron emission tomography (PET) radioligands for the 5-HT neurotransmitter system is an important target to enable the understanding of human 5-HT function in vivo. ["1"1C]CUMI-101, proposed as the first 5-HT_1_A receptor agonist PET ligand, has been reported to behave as a potent 5-HT_1_A agonist in a cellular system stably expressing human recombinant 5-HT_1_A receptors. In this study, we investigate the agonist properties of CUMI-101 in rat brain tissue. Methods: ["3"5S]-GTP#gamma#S binding studies were used to determine receptor function in HEK (human embryonic kidney) 293 cells transfected with human recombinant 5-HT_1_A receptors and in rat cortex and rat hippocampal tissue, following administration of CUMI-101 and standard 5-HT1A antagonists (5-HT, 5-CT and 8-OH-DPAT). Results: CUMI-101 behaved as an agonist at human recombinant 5-HT_1_A receptors (pEC_5_0 9.2). However, CUMI-101 did not show agonist activity in either ...
2011-02-01
International Nuclear Information System (INIS)
"1"8F-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of "1"8F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. From April 2005 to May 2008, eighty two patients (M:F=55:27, age 66.2#+-#9.6 yrs) with CC underwent "1"8F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV_m_a_x) was obtained from the primary tumor. The difference of SUV_m_a_x according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Overall sensitivity of PET scan was 81.7% in CC. SUV_m_a_x on PET scan in intrahepatic CC was significantly ...
2009-08-01
Correlation of angiogenesis with "1"8F-FMT and "1"8F-FDG uptake in non-small cell lung cancer
International Nuclear Information System (INIS)
L-[3-"1"8F]-#alpha#-methyltyrosine ("1"8F-FMT) is an amino-acid tracer for positron-emission tomography (PET). We have conducted a clinicopathologic study to elucidate the correlation of angiogenesis with "1"8F-FMT and 2-["1"8F]-fluoro-2-deoxy-D-glucose ("1"8F-FDG) uptake in patients with non-small cell lung cancer (NSCLC). Thirty-seven NSCLC patients were enrolled in this study, and two PET studies with "1"8F-FMT and "1"8F-FDG were performed. Uptake of PET tracers was evaluated with standardized uptake value. Vascular endothelial growth factor (VEGF), CD31, CD34, L-type amino acid transporter 1 (LAT1) and Ki-67 labeling index of the resected tumors were analyzed by immunohistochemical staining, and correlated with the clinicopathologic variables and the uptake of PET tracers. The median VEGF rate was 45% (range, 10-78%). High expression was seen in 30 patients (81%, 30/37). VEGF expression was statistically associated with progressively growing microvessel count. ...
2009-04-01
Correlating microstructure and thermal transport of irradiated SiC
International Nuclear Information System (INIS)
Full text of publication follows: The effect of neutron irradiation on the thermal conductivity of silicon carbide can be dramatic depending on the irradiation temperature and fluence the material is subjected to, and may be a critical factor defining it's use in fusion systems. Historically there have been several papers describing the effect of neutron irradiation on thermal conductivity degradation of SiC, predominately in the low to intermediate temperature ranges. Practically all of this work has been at temperatures lower than the application temperature for SiC being considered by the conceptual fusion reactors. This paper provides new data on the thermal conductivity of high quality CVD silicon carbide irradiated in a range of doses and temperature spanning the proposed fusion reactor temperature range. Specifically, an irradiation was carried out from fractions milli-dpa to approximately 8 dpa in the HFIR with irradiation temperatures ranging from 80-1600 deg. C. Results of ...
2007-12-10
Composition, structure and evolution of neutron stars with kaon condensates
International Nuclear Information System (INIS)
We investigate the possibility of kaon condensation in the dense interior of neutron stars through the s-wave interaction of kaons with nucleons. We include nucleon-nucleon interactions by using simple parametrizations of realistic forces, and include electrons and muons in #beta#-equilibrium. The equation of state above the condensate threshold is derived in the mean field approximation. The conditions under which kaon condensed cores undergo a transition to quark matter containing strange quarks are also established.The critical density for kaon condensation lies in the range (2.3-5.0)#rho#_0, where #rho#_0=0.16 fm"-"3 is the equilibrium density of nuclear matter. The critical density depends largely on the value of the strangeness content of the proton, the size of which is controversial. For too large a value of the strangeness content, matter with a kaon condensate is not sufficiently stiff to support the lower limit of 1.44 M_o_e_d_o_t for a neutron star. Kaon condensation ...
Calibration of the Capintec CRC-712M dose calibrator for "1"8F
International Nuclear Information System (INIS)
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties given above are expanded uncertainties ...
2006-04-01
Analysis of the D+ --> K- pi+ e+ nu_e decay channel
Using 347.5 fb-1 of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244*10^3 signal events for the D+ --> K- pi+ e+ nu_e decay channel are analyzed. This decay mode is dominated by the \\bar{K}^*(892)^0 contribution. We determine the \\bar{K}^*(892)^0 parameters: m_{K^*(892)^0}=(895.4 +- 0.2 +- 0.2) MeV/c^{2}, \\Gamma^0_{K^*(892)^0}=(46.5 +- 0.3 +- 0.2) MeV/c^{2} and the Blatt-Weisskopf parameter $r_{BW}=2.1 +- 0.5 +- 0.5 (GeV/c)^{-1} where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q^{2}=0 (r_{V} = V(0) / A_{1}(0)=1.463 +- 0.017 +- 0.031, r_{2} = A_{2}(0) / A_{1}(0) = 0.801 +- 0.020 +- 0.020) and the value of the axial-vector pole mass parameterizing the q^2 variation of A_{1} and A_{2}: m_{A}=(2.63 +- 0.10 +- 0.13) GeV/c^{2}. The S-wave fraction is equal to (5.79 +- 0.16 +- 0.15)%. Other signal ...
2010-01-01
A study of radiation embrittlement using simulation irradiation
International Nuclear Information System (INIS)
Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeV electrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage provides additional cluster nucleation sites to compensate for lower free point defect production. High dose rate Ni ion irradiation produced Mn-Ni-Si clusters and ...
2008-10-13
Uptake of radiolabeled ions in normal and ischemia-damaged brain
Energy Technology Data Exchange (ETDEWEB)
The regional concentrations of nine radiochemicals were measured in rat brain after induction of cerebral ischemia to identify tracers concentrated by brain undergoing selective neuronal necrosis. Transient (30 minute) forebrain ischemia was produced in the rat; 24 hours after cerebral recirculation the radiochemicals were injected intravenously and allowed to circulate for 5 hours. The brain concentrations of the radiochemicals in dissected regions were determined by scintillation counting. Forebrain ischemia of this nature will produce extensive injury to striatal neurons but will spare the great majority of neocortical neurons at 24 hours. The regional concentrations of these radiochemicals varied considerably in both control and ischemic animals. In postischemic animals, 4 radionuclides (/sup 63/Ni, /sup 99/TcO/sub 4/, /sup 22/Na, and (/sup 3/H)tetracycline) were concentrated in the irreversibly damaged striatum in amounts ranging from 1.4 to 2.4 times greater than in normal ...
1986-05-01
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, ...
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
Background: Cu-diacetyl-bis(N{sup 4}-methylthiosemicarbazone) [Cu-ATSM], although excellent for oncology applications, may not be suitable for delineating cardiovascular or neurological hypoxia. For this reason, new Cu hypoxia positron emission tomography (PET) imaging agents are being examined to search for a higher selectivity for hypoxic or ischemic tissue at higher oxygen concentrations found in these tissues. Two approaches are to increase alkylation or to replace the sulfur atoms with selenium, resulting in the formation of selenosemicarbazones. Methods: Three {sup 64}Cu-labeled selenosemicarbazone complexes were synthesized and one was screened for hypoxia selectivity in vitro using EMT-6 mouse mammary carcinoma cells. Rodent biodistribution and small animal PET images were obtained from BALB/c mice implanted with EMT-6 tumors. One alkylated thiosemicarbazone was synthesized and examined. Results: Of the three bis(selenosemicarbazone) ligands synthesized and ...
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} Charge Current (CC) ...
1990-01-01
Concepts of radiotherapy treatment planning
International Nuclear Information System (INIS)
Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance images (MRI) of function. Positron emission tomographic (PET) imaging ...
2000-12-01
Energy Technology Data Exchange (ETDEWEB)
Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission computed ...
2003-12-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
