... stenosis. It looks from the transesophageal and the 3-D echo that most of the problem is really ... posterior leaflet, which you can see on the 3-D echo image is a major source. The anterior ...
Escherichia coli strains producing extended-spectrum β-lactamases (ESBLs) are a major problem in many different hospitals worldwide, causing outbreaks as well as sporadic infections....Full Text Available
Sporadic Creutzfeldt-Jakob-disease (sCJD) is a fatal neurodegenerative condition that escapes detection until autopsy. Recently, brain iron dyshomeostasis accompanied by increased transferrin (Tf) was...Full Text Available
Using spectral hole-burning-based ultraslow group velocity in a dilute solid medium, we report enhanced photon echo efficiency three orders of magnitude higher than that in a nonslow light regime. The enhancement is due to exponentially increased absorption of an optical data pulse owing to the enhanced photon-atom interaction in an ultraslow light regime, whereas echo reabsorption is negligibly small due to group-velocity dependent population depletion.
We have examined the theory of NMR multiple echoes developed for solid {sup 3}He to determine whether multiple echoes could be observed in solid hydrogen. We were particularly interested in the possibility of testing for low frequency quantum tunneling motions in solid hydrogen by the observation of multiple echoes. We find that for easily accessible nuclear spin polarizations, P > 12%, multiple echoes would be observed for HD impurities in solid parahydrogen if motional narrowing is effective in increasing the HD nuclear spin-spin relaxation time T{sub 2} to the order of 1 msec. These values for T{sub 2}, which have been observed for HD impurity concentrations of the order of 1%, are larger than the calculated rigid lattice values and can be attributed to quantum tunneling at frequencies of the order of 1kHz.
T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is ...
Single-shot spin-echo diffusion-weighted echo-planar imaging using a phased-array multicoil was performed to distinguish between normal and cirrhotic livers. Sets of 6 images with different b-value were acquired with breath-holding. Significant differences were observed between controls and cirrhosis cases in the signal ratios when the b-value was 383 s/mm{sup 2}, and apparent diffusion coefficients. (orig.)
The applications of neutron reflectometry to study dynamic phenomena at surface and interfaces have been restricted so far. This was mainly due to the low intensity of neutron sources, but now high-intensity spallation neutron sources are under construction in Japan (J-PARC) and US (SNS). We are planning to install a spin-echo option on the J-PARC neutron reflectometer with horizontal sample geometry for studies of dynamics of surfaces and interfaces. This option is based on the resonance spin-echo method and aimed at dynamics up to hundreds of nanoseconds. In this contribution, the plan and status of development are introduced together with the principle and characteristics of this option.
This data set contains data from in situ infrared thermometer measurements ... Surface temperature was measured using an Apogee Infrared Thermometer from 23 ...
Defects in mismatch repair genes cause the genetic instability characteristic of hereditary nonpolyposis colorectal cancer and a subset of sporadic colon tumors. The newest member of the mismatch repair gene family, GTBP, has recently been identified as a partial cDNA. Here, we describe the isolation of its 5{prime} terminus, allowing definition of the entire coding region. Several polymorphisms within the 5{prime} end were identified and are presented. 13 refs., 1 fig.
Artifical valve prostheses are often regarded as a contraindication for magnetic resonance imaging (MRI), although preliminary in vitro studies suggested, that patients with these metallic implants might safely undergo MR examination. This study reports on the experience with a group of 89 patients with 100 heart valve prostheses who were examined by spin-echo MR and gradient-echo MR. MR examination was performed in all patients without complications. The spin-echo sequence showed advantages in the depiction of anatomical structures like paravalvular abcesses. Anatomical structures adjacent to the artificial valve were clearly visivle and the metal components of the valves showes no or only small artifacts. Artifacts were accentuated when using gradient-echo sequences. Gradient-echo sequences provided valuable information regarding the presence of valvular insufficiency. ...
Anatomical specimens and normal persons were studied by gradient echo MR imaging to determine the influence of different echo times (TE) on bone marrow contrast. First of all, six normal persons were studied to determine specific echo times for in-phase and opposed-phase states. Using different sequences bone marrow contrast in isolated femoral bones was determined and compared to results of pathological exams. Red bone marrow had no signal on opposed-phase images; contrast between red and yellow marrow was higher on opposed-phase than on in-phase images. Bone marrow lesions can be expected to be visualised with high signal on opposed-phase images; this technique should be especially suited for MR imaging of bone marrow. (orig.).
Scientists have just taken a big step toward understanding the cause of Lou Gehrig's disease, one of the most devastating nerve degenerative diseases. A large team of researchers, led by Robert Brown Jr. of Harvards's Massachusetts General Hospital and Robert Horvitz, a Howard Hughes Medical Institute investigator at the Massachusetts Institute of Technology, report in the 4 March Nature that they've identified the gene that causes a hereditary form of the condition, which also goes by the name amyothophic lateral sclerosis (ALS). While most ALS cases - approximately 90% - are apparently sporadic' and not caused by an inherited gene defect, all the patients have such similar symptons that researchers are hopeful that what they learn about hereditary ALS will also apply to the sporadic form, possibly leading to new therapeutic strategies that will help both. It's a very important finding,' ...
Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).
This paper investigates regional and age-related changes in metabolite ratios using image-localized H-1 MR spectroscopy in children. Twenty-seven children referred for MR imaging of the brain underwent localized H-1 MR spectroscopy with a Siemens 1.5-T whole-body imager. Localization to 2 x 2 x 2-cm volumes of interest was achieved with a stimulated-echo or spin-echo technique. Repetition times of 1,600 and 5,000 msec were used, with echo times varying between 68 and 270 msec. Total combined imaging and spectroscopy times were 90-120 minutes.
VHF wind-profiling radars often measure a decrease of echo power with zenith angle, which can be explained from in situ measurements of horizontal layering or anisotropy of metre-scale temperature structure in the atmosphere. There can also be an azimuthal variation of echo power, which is increased in an azimuth opposite to the vertical shear vector of horizontal wind. This paper checks if the azimuth variation can also be linked to in situ observations of temperature structure, using aircraft flights in the tropopause region near a VHF radar. At heights where VHF radar measures wind shear and aspect sensitivity, there can be an asymmetry in the probability distribution of horizontal gradient of potential temperature, for horizontal scale of e.g. hundreds of metres. The asymmetry is often...
Ten patients with traumatic femoral neck fracture were studied with MR imaging (0.5 T, Magnetom, Siemens): unenhanced (multiecho, TR/TE = 1,600/30--240 [repetition time/echo time, msec]; gradient echo, TR/TE = 315/14, #theta# = 90 degrees) and Gd-DTPA enhanced (0.1 mM/kg body weight, Magnevist, Schering; gradient echo, TR/TE = 315/14, #theta# = 90 degrees). MR images were compared with clinical-radiographic findings. Digital subtraction angiography of the femoral head (FH) in five patients showed complete interruption of blood supply to the FH in three patients (signal intensity of FH did not increase on postcontrast images) and intact FH arteries in two patients (FH signal increased on postcontrast images, as did the healthy-side signal).
T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, ...
Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: ...
Changes in cell density and cyst flux of Alexandrium tamarense, paralytic shellfish poisoning (PSP) toxin contents in shellfishes, and environmental parameters were measured in two stations in Daya Bay, South China Sea from March 2005 to July 2006. Vegetative cells of A. tamarense occurred sporadically; however, they presented abundantly during the winter months. Meanwhile, cyst flux reached its maximum level just following the peak abundance of motile cells. The PSP contents in shellfish were generally low, but higher in winter with the maximum of 14,015 @mg STX equiv./kg. The majority of toxins were found in digestive glands, with a maximum of 66,227 @mg STX equiv./kg. There were significant positive relationships between toxin level and vegetative cell density and cyst flux. This indica...
Batadomba-lena, a rockshelter in the rainforest of southwestern Sri Lanka, has yielded some of the earliest evidence of Homo sapiens in South Asia. H. sapiens foragers were present at Batadomba-lena from ca. 36,000 cal BP to the terminal Pleistocene and Holocene. Human occupation was sporadic before the global Last Glacial Maximum (LGM). Batadomba-lena's Late Pleistocene inhabitants foraged for a broad spectrum of plant and mainly arboreal animal resources (monkeys, squirrels and abundant rainforest snails), derived from a landscape that retained equatorial rainforest cover through periods of pronounced regional aridity during the LGM. Juxtaposed hearths, palaeofloors with habitation debris, postholes, excavated pits, and animal and plant remains, including abundant Canarium nutshells, ref...
Ichnogenera belonging to cleft-foot and wedge-foot bivalves can in most cases be distinguished. This paper addresses the taxonomy of locomotion traces made by wedge-foot bivalves. Ichnogenera Ptychoplasma Fenton and Fenton and Oravaichnium Plicka and Uhrova are reviewed together with related ichnotaxa. Both are interpreted as the locomotion traces of non-cleft, wedge-foot bivalves. Both are usually preserved as hypichnial ridges that include a distinctive bioprint of amygdaloid segments. Ptychoplasma is dominated by amygdaloid segments whereas Oravaichnium is wall-like with only sporadic amygdaloid segments. Ichnospecies of Ptychoplasma are distinguished on the basis of their continuity: P. excelsum Fenton and Fenton (the type) is a relatively continuous trace fossil consisting largely of ...
Partial adrenalectomy is usually performed for the treatment of bilateral pheochromocytomas and in case of sporadic, monolateral tumors, to minimize the risk of adrenal failure, especially in younger patients. Due to the lack of consistent series, many issues such as correct surgical indications and technical aspects still need to be debated. From 2007 to 2010 we performed four unilateral partial adrenalectomies (3 aldosterone-producing adenomas and 1 cortisol-producing adenoma), and three bilateral subtotal adrenalectomies, consisting in total adrenalectomy on one side and partial adrenalectomy on the contralateral gland (3 bilateral pheochromocytomas in MEN IIa). In case of single tumor, partial adrenalectomy was carried out without adrenal vein ligation and the results were similar to t...
Alzheimer's disease (AD) is the most common form of neurodegenerative disease. The vast majority cases of AD are sporadic, without clear cause, and a combination of environmental and genetic factors has been implicated. The hypothesis that homocysteine (Hcy) is a risk factor for AD was initially prompted by the observation that patients with histologically confirmed AD had higher plasma levels of Hcy, termed hyperhomocysteinemia (HHcy), than age-matched controls. Most evidence accumulated so far implicates HHcy as a risk factor for AD onset, but there are also conflicting results. In this review we summarize reports on the relationship between HHcy and AD from epidemiological investigations, including observational studies and randomized controlled clinical trials. We also examine recent i...
Aluminium phosphide ingestion is the most common agricultural poisoning in suburban and rural India and with a high mortality rate. Among survivors of acute poisoning there are recent sporadic reports of esophageal complications such as esophageal strictures and tracheo-esophageal fistula. The present study was carried out to determine the incidence, natural history, and treatment outcome of local esophageal complications in survivors of aluminium phosphide poisoning with complaints of dysphagia. All confirmed cases of poisoning with aluminium phosphide ingestion were admitted in Hamidia Hospital, Gandhi Medical College, Bhopal, Madhya Pradesh, India, from October 2007 to October 2008. Survivors with complaints of dysphagia underwent a barium study and upper gastrointestinal endoscopy to d...
Abstract Hereditary primary hyperparathyroidism (HPT) may develop as a solitary endocrinopathy (FIHP) or as part of multiple endocrine neoplasia Type 1, multiple endocrine neoplasia Type 2A, or hereditary HPT-jaw tumor syndrome. Inactivating germline mutations of the tumor suppressor gene CDC73 account for 14 and 50% of all FIHP and HPT-JT patients, respectively, and have also been found in almost 20% of apparently sporadic parathyroid carcinoma patients. Although more than 60 independent germline mutations have been described, to date no rearrangement affecting the CDC73 locus has been identified. By means of multiplex-PCR we found a large germline deletion affecting the whole gene in a two-generation HPT-JT family. Subsequently array-CGH and specific PCR analysis determined that the muta...
An attempt to determine lysozyme hydration by employing a proton nuclear magnetic resonance (NMR) spin-echo technique and to correlated such measurements with the 20 "0C sorption equilibrium data is made. Determinations of specific site hydration for lysozyme, as well as proton NMR transverse relaxation rates for five different types of water populations in the lysozyme-water system, are presented over the whole range of lysozyme concentrations. The proton spin-echo NMR results are consistent with a three-component analysis of the sorption isotherm up to 70% water content, above which two additional water populations are identified by 360-MHz proton NMR spin-echoes. On the basis of the proton NMR results, a major component (III) of the lysozyme sorption isotherm is assigned to the water trapped between lysozyem molecules, whose relaxation rate is increased by diffusion barriers. The trapped water population dominates the ...
MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).
This paper introduces the application of independent component analysis mixture modelling (ICAMM) in non-destructive testing (NDT). The application consists of discriminating patterns for material quality control from homogeneous and defective materials inspected by impact-echo testing. This problem is modelled as a mixture of independent component analysis (ICA) models, representing a class of defective or homogeneous material by an ICA model whose parameters are learned from the impact-echo signal spectrum. These parameters define a kind of particular signature for the different defects. The proposed procedure is intended to exploit to the maximum the information obtained with the cost efficiency of only a single impact. To illustrate this capability, four levels of classification detail...
We investigate decoherence in quantum systems coupled via dephasing-type interactions to an arbitrary environment with chaotic underlying classical dynamics. The coherences of the reduced state of the central system written in the preferential energy eigenbasis are quantum Loschmidt echoes, which in the strong coupling regime are characterized at long times scales by fluctuations around a constant mean value. We show that due to the chaotic dynamics of the environment, the mean value and the width of the Loschmidt echo fluctuations are inversely proportional to the quantity we define as the effective Hilbert space dimension of the environment, which in general is smaller than the dimension of the entire available Hilbert space. Nevertheless, in the semiclassical regime this effective Hilbert space dimension is in general large, in which case even a chaotic environment with few degrees of freedom produces decoherence without revivals. Moreover ...
Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.
Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR Imaging of the joints. (orig.) [Deutsch] ...
The susceptibility of solid "3He is deduced from multiple echoes observed in pulsed NMR experiments. It follows a Curie Weiss law at high temperature, increases faster than this law below 5 mK and drops abruptly around 1 mK. (Auth.).
A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available
Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other cases, the TIRM signal was diagnostically equivalent. On the TIRM ...
An experiment was conducted on the structure of mesoscopic calculating method for cement-based composite materials. The purpose was utilization for the simulation of mesoscale failure processes and the development of new composite materials. Mesh split based on Voronoi polygons was applied as the discrete limit analysis of the cement-based composite materials containing aggregate particles taking the arrangement of random particles into consideration, and a two-dimensional rigid-body/spring model was employed as the model. The nonhomogeneity of concrete was represented by three kinds of different spring parameters which were aggregate, mortar matrix and their interfaces. The simulation results were summarized as follows: The stress-strain curve went into a non-linear state from the 30% of the maximum stress. The generation of interfacial crack started on the side of the aggregate, but the propagation of the crack was stable. Deformation became unstable at 80% of the maximum stress, and ...
The feasibility of using hydrogen as the sole fuel in a direct injection diesel engine was investigated. An air cooled single cylinder Lister ST1 diesel engine was modified to operate as a low-heat-rejection engine for this study. Partially stabilized zirconia ceramic parts were used to shield the combustion space of the engine. Using a compression ratio of 17.9:1 and motoring the test engine at 21000 rpm, a maximum compression temperature of approximately 900 K was achieved. Under these operating conditions, all lubricants tested were found to burn. Lowering the speed to 1450 rpm and the compression ratio to 17.1, lubricant combustion and hot spots were successfully eliminated. The maximum compression temperature, when compression ignition of hydrogen was tried, was in the 800 K range. The corresponding ceramic surface temperature was estimated to reach 600-700 K. Only sporadic compression ignition of hydrogen was achievable. (author).
Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary abscesses. In 93% the ...
Cerebral maturation in the human fetal brain was investigated by in utero localized proton magnetic resonance spectroscopy (MRS). Spectra were acquired on a clinical MR system operating at 1.5 T. Body phased array coils (four coils) were used in combination with spinal coils (two coils). The size of the nominal volume of interest (VOI) was 4.5 cm"3 (20 mm x 15 mm x 15 mm). The MRS acquisitions were performed using a spin echo sequence at short and long echo times (TE = 30 ms and 135 ms) with a VOI located within the cerebral hemisphere at the level of the centrum semiovale. A significant reduction in myo-inositol and choline and an increase in N-acetylaspartate were observed with progressive age. The normal MR spectroscopy data reported here will help to determine whether brain metabolism is altered, especially when subtle anatomic changes are observed on conventional images. Some examples of impaired fetal brain development studied by MRS are ...
MRI, ultrasonography and angiography were performed on 24 cases with small renal cell carcinoma, and data were compared with pathological architecture type. An average diameter of cancer was 20.8 mm (10-30 mm). Each tumor was pathologically classified into four architecture types: alveolar type (15 cases), papillary type (5 cases), tubular type (3 cases) and cystic type (1 case). In comparison with renal cortex alveolar type renal cell carcinoma showed equal or low signal in T1-weighted images and equal or high signal in T2-weighted images. Papillary and tubular types showed high signal in T1-weighted images, and low signal in T2-weighted images. In alveolar type, many cases showed equal echo in ultrasonography and hypervascularity in angiography, and in papillary and tubular types, many cases showed high echo and hypovascularity. There were many cases with papillary type small cell carcinoma which showed low signal intensity of T2-weighted ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: ...
The results of these investigations can be summarised as follows: At simulated operating stress most naturally occuring faults in welded- and cast iron parts develop cracks and can be assessed for reliability under fatigue-,creep- and creep fatigue behaviour according to the laws of fracture mechanics. The empirically determined correlation between the real fault size and the ultrasonic inspection results (height of echo, echo dynamics, sound weakening) lead to better assessment of real fault extension in turbine components. It is very important to adapt the method of inspection and assessment to the type of possible fault.(orig.) [German] Die bei diesen Untersuchungen ermittelten Ergebnisse lassen sich wie folgt zusammenfassen: - Die Mehrzahl der untersuchten natuerlichen Fehlstellen in den Schmiede- und Gussstuecken verhalten sich unter den simulierten Betriebsbeanspruchungen rissartig und sind damit mittels den bruchmechanischen Gesetzen in ...
This is a prompt report. These days the importance of acquiring knowledge about the structure from the lower crust down to the upper mantle is often discussed with reference taken to Hyogo-ken Nanbu Earthquake. The Hidaka collision belt where the lower crust is exposed on the surface is a rare phenomenon in the world and has been the subject of seismic survey. As a part of the survey, experiments are conducted by the use of vibrations produced by Vibroseis and dynamite sources. Every one of the shot records (20-second record) from the two types of vibration sources contains a clear echo in the vicinity of 16 seconds supposedly from a level deeper than 40 kilometers, not to mention reflections from shallow levels. Although some studies have to be conducted before the reflecting geological boundary (possibly the upper mantle) of the echo near the 16-second point can be identified, yet this is probably the reflection from the deepest level ever ...
Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 and 24 of 25 lesions of ...
The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)
Proton magnetic resonance spectroscopy (MRS) measures concentrations of metabolites in vivo and provides a powerful method for identifying tumours. MRS has not entered routine clinical use partly due to the difficulty of analysing the spectra. To create a straightforward method for interpreting short-echo-time MRS of childhood cerebellar tumours. Single-voxel MRS (1.5-T Siemens Symphony NUM4, TR/TE 1,500/30 ms) was performed at presentation in 30 children with cerebellar tumours. The MRS results were analysed for comparison with histological diagnosis. Peak heights for N-acetyl aspartate (NAA), creatine (Cr), choline (Cho) and myo-inositol (mIns) were determined and receiver operator characteristic curves used to select ratios that best discriminated between the tumour types. The method was implemented by a group of clinicians and scientists, blinded to the results. A total of 27 MRS studies met the quality control criteria. NAA/Cr >4.0 distinguished all but ...
To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children ...
This paper reports, to complement current knowledge on brain development, late regional brain maturation assessed with quantitative MR imaging. Axial and coronal head spin-echo (SE) images were obtained in 60 healthy individuals aged 5--56 years, with a double-echo, flow compensated imaging sequence obtained with a 1.5-T Magnetom spectroscopy and imaging system. T2-weighted images were calculated from the intensity differences in SE images at echo times (TEs) of 15 and 90 msec (TR = 2.5 second). The mean T2 values were determined at 16 sites in each cerebral hemisphere. T2 values of the six frontal subcortical white matter (FSCWM) sites and of the internal capsule (IC) were evaluated. Mean T2 values in the IC decreased until age 10 years, whereas this decrease continued in the FSCWM past age 15 years before reaching a plateau. Differential age-dependent patterns of mean T2 values emerged between the six FSCWM sites. The ...
A four-stage scoring system for brain maturation was established with MR imaging. First, gyration and myelination were analyzed in 50 anamnestically normal children (32-240 weeks postconceptional age). Subsequently 60 patients (same age range) with birth asphyxia, seizures, or developmental delays were evaluated analogously. T1- and T2-weighted images (500/30 and 3,000/120 [repetition time msec/echo time msec]) were obtained with a 2.35-T magnet in all children. Whereas gyration abnormalities were seen in some patients, all handicapped children presented with delayed myelination. In conclusion, prospective staging of brain development (gyration and myelination) is possible and is best obtained with T2-weighted images.
This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)
A newly developed method to support tissue characterization in routine MR imaging is presented. It represents a compromise between the practical requirements of clinical routine (short measurement time, multisection imaging) and the necessary accuracy of the relaxation parameter evaluation. The sequence employed is a modification of the PHAPS technique and works with two excitation pulses. It allows the simultaneous acquisition of all measurement data for the subsequent T1, T2, and rho evaluations. T1 is determined with a specially designed computation formula based on four signal ratios. A multiexponential T2 analysis is performed with use of 28 echoes. From these parameters, relative proton density can be computed.
Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the detection of pulmonary ...
Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub 1}-weighted images. Only scattered fatty ...
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was ...
Color Doppler flow mapping (CDFM) was performed in 47 normal women ages 18-41 mean (m) 28 to determine the normal flow phenomena across each of the 4 heart valves. The group included: 15 elite marathon runners average run (ave.) 70 miles/week, heart rate (HR) 35-54 (m 45); 14 joggers ave. 40 mi/wkm HR 40-69 (m 53); and 17 controls 0 mi/wk, HR 49-93 (m 77). 2-D echo and CDFM defined the motion of each valve, including the presence of mitral valve prolapse (MVP), the ventricular inflow and outflow patterns and the presence of regurgitation.
An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a continuously varying focus in accordance ...
Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).
Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...
BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate patient safety learning into existing curriculum. DESIGN: To address this gap and provide ...
BACKGROUND: The urgent need for patient safety education for healthcare students has been recognised by many accreditation bodies, but to date there has been sporadic attention to undergraduate/graduate medical programmes. Medical students themselves have identified quality and safety of care as an important area of instruction; as future doctors and healthcare leaders, they must be prepared to practise safe healthcare. Medical education has yet to fully embrace patient safety concepts and principles into existing medical curricula. Universities are continuing to produce graduate doctors lacking in the patient safety knowledge, skills and behaviours thought necessary to deliver safe care. A significant challenge is that patient safety is still a relatively new concept and area of study; thus, many medical educators are unfamiliar with the literature and unsure how to integrate patient safety learning into existing curriculum. DESIGN: To address this gap and provide ...
Objective: To assess the efficacy, prospects and future of conservative management of beta thalassemia major patients in a developing country. Design: Patients registered at IHBTS were studied over a period of three years. They consented to being managed on moderate transfusion regimen, aiming to maintain a pre-transfusion haemoglobin(Hgb) level of 9.0 plus minus 1.0 g per dL. We studied their transfusion requirements, status for transfusion transmitted infections (TTls), serum ferritin levels and complications developing as a result of iron overload. Subjects: Initially all registered patients were included in this study. Sporadic patients as well as dropouts occurring due to any reason, (patients concurrently seeking treatment at other centres as well, or complying poorly to advised chelation therapy) were excluded from the study. The data presented here conforms to a cohort of 60 regular patients who adhered best to our selection criteria. Main Outcome Measures: ...
Neuronal cell death induced by oxidative stress is correlated with numerous neurodegenerative diseases, including Alzheimer's disease (AD), Parkinson's disease (PD), and stroke. The causes of sporadic forms of age-related neurodegenerative diseases are still unknown. Recently, a correlation between paraquat exposure and neurodegenerative diseases has been observed. Paraquat, a nonselective herbicide, was once widely used in North America and is still routinely used in Taiwan. We have used differentiated Human Neuroblastoma (SHSY-5Y) cells as an in vitro model to study the mechanism of cell death induced by paraquat. We observed that paraquat-induced oxidative stress in differentiated SHSY-5Y cells as indicated by an increase in the production of cellular reactive oxygen species (ROS). Furthermore, apoptosis was evident as indicated by cellular and nuclear morphology and DNA fragmentation. Interestingly, pretreatment of SHSY-5Y cells with water-soluble Coenzyme ...
BACKGROUND: Denys-Drash Syndrome (DDS) is an uncommon disorder that appears sporadically and in rare cases may be inherited as an autosomal dominant trait It manifests either at birth or within the first year of life and typically consists of the triad of congenital nephropathy, Wilms tumour and intersex disorder. CASE REPORT: A 10 year-old Caucasian girl was referred to the Dental Department, at Glasgow Royal Hospital for Sick Children by her Paediatric Nephrologist Consultant. The patient was being teased by her peers over her markedly discoloured teeth. The dental history revealed that the patient was a regular dental attendee from an early age. She was dentally anxious having only experienced dental treatment under general anaesthesia (GA) when she was 4 years old. Apparently her primary dentition also showed a generalised discolouration. TREATMENT: This consisted of multiple visits for diet analysis and tooth brushing instruction with the use of disclosing ...
Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no ...
Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric ...
The purpose of this study was to correlate MR imaging findings with pathology in experimental hyperoxia-induced acute lung injury, which has similar pathology to diffuse alveolar damage (DAD). Seventeen Yorkshire pigs were studied. These animals were exposed to more than 80% oxygen for 24, 48, 72, and 96 hours in a sealed cage. The lungs were removed and inflated with air infused through the trachea, and then examined by both MRI and high-resolution CT (HRCT). T1-weighted spin-echo (T1WSE), T2-weighted fast (T2WFSE), and half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences were performed. Severity in MR findings and signal-to-noise ratios (SNR) on MR images were well correlated with pathological scores. CT values were also correlated well with pathologic scores. Abnormal SNR values were obtained from a pathological score of 5, whereas abnormal CT values were obtained from a pathological score of 15. Furthermore, significant ...
The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus, it is difficult to compare task-induced fMRI signals across subjects, field strengths, and pulse sequences. This problem can be overcome by normalizing the neural activity-induced BOLD fMRI response by a global hypercapnia-induced BOLD signal. To demonstrate the effectiveness of the BOLD normalization approach, gradient-echo BOLD fMRI at 1.5, 4, and 7 T and spin-echo BOLD fMRI at 4 T were performed in human subjects. For neural stimulation, subjects performed sequential finger movements at 2 Hz, while for global stimulation, subjects breathed a 5% CO(2) ...
To find out the sonographic findings that are useful to differentiate hepatic abscess from peripheral cholangiocarcinoma. Twenty-two hepatic abscesses and 22 peripheral cholangiocarcinomas which had been confirmed histologically were included in this study. Objective points were echo characteristics of the lesion, internal septation, presence of peripheral low echoic rim, demarcation from normal liver(well or poorly defined), posterior enhancement, multiplicity, dilatation of bile duct(obstructive or non-obstructive), intrahepatic duct stone, pleural effusion, and intra-abdominal fluid collection. Echo characteristics of the lesion were classified in-to four types. Type I; Predominantly echogenic with hypoechoic portion, type II; Echogenic without hypoechoic portion, type III; Predominantly hypoechoic with echogenic portion, type IV; Hypoechoic without echogenic portion. 1)Nine abscesses and 2 peripheral cholangiocarcinomas were type ...
Lipiodol Ultra-Fluid (Lipiodol) is widely applied in the transcatheter arterial embolization (TAE). We studied signal intensity, the T1 relaxation time and the T2 relaxation time of Lipiodol itself using Siemens Magnetom H15-2 T (1.5 Tesla) and Magnetom M10 (1.0 Tesla). Lipiodol showed higher signal intensity than saline solution on the T1-weighted images (short TR, short TE technique in spin echo method). On the T2-weighted images (long TR, long TE technique in spin echo method), Lipiodol showed lower signal intensity than saline solution. The T1 relaxation time of Lipiodol, measured at 1.0 T, was 201 msec and 218 msec at 1.5 T. The T2 relaxation time of Lipiodol, measured at 1.0 T, was 127 msec; and 167 msec at 1.5 T. The signal intensity of Lipiodol at 1.0 T was higher than the intensity at 1.5 T. Shorter T1 relaxation time of Lipiodol at 1.0 T is probably responsible for the higher intensity at 1.0 T. When MRI is performed after TAE with ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic reference deviations ...
The purpose of this study is to investigate the role of femoral marrow MR imaging as predictor of outcome for hemopoietic stem cell transplantation (HSCT) in beta-thalassemia major. MR imaging of the proximal femur, including T1- and T2-weighted spin echo and short-tau inversion recovery and in-phase and out-of-phase fast field echo images, was prospectively performed in 27 thalassemia major patients being prepared for HSCT. The area of red marrow and its percentage of the proximal femur were measured, and the presence of marrow hemosiderosis was assessed. Age-adjusted multivariate logistic regression was used to determine the relationship between red marrow area percentage and marrow hemosiderosis and HSCT outcome. Red area percentage were less in patients with successful (90.25{+-}4.14%) compared to unsuccessful transplants (94.54% {+-}2.93%; p=0.01). Red marrow area percentage correlated positively with duration of symptoms(r=0.428, p=0.026) ...
Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep ...
AbstractPurpose: To implement and examine the feasibility of a three-dimensional (3D) ultrashort TE (UTE) sequence on a 7 Tesla (T) clinical MR scanner in comparison with 3T MRI at high isotropic resolution. Materials and Methods: Using an in-house built saddle coil at both field strengths we have imaged mid-diaphysial sections of five fresh cadaveric specimens of the distal tibia. An additional in vivo scan was performed at 7 Tesla using a quadrature knee coil. Results: Using the same type of saddle coil at both field strengths, a significant increase in SNR at 7T compared with 3T (factor 1.7) was found. Significantly shorter T2* values were found at the higher field strength (T2* = 552.2 126 s at 7T versus T2* = 1163 391 s at 3T). Conclusion: UHF MRI at 7T has great potential for imaging...
The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2 weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. Amongst 49 patients in whom the suspected ...
We report the results of a worldwide campaign to observe WZ Sagittae during its 2001 superoutburst. After a 23-year slumber at V=15.5, the star rose within 2 days to a peak brightness of 8.2, and showed a main eruption lasting 25 days. The return to quiescence was punctuated by 12 small eruptions, of ~1 mag amplitude and 2 day recurrence time; these "echo outbursts" are of uncertain origin, but somewhat resemble the normal outbursts of dwarf novae. After 52 days, the star began a slow decline to quiescence. Periodic waves in the light curve closely followed the pattern seen in the 1978 superoutburst: a strong orbital signal dominated the first 12 days, followed by a powerful /common superhump/ at 0.05721(5) d, 0.92(8)% longer than P_orb. The latter endured for at least 90 days, although probably mutating into a "late" superhump with a slightly longer mean period [0.05736(5) d]. The superhump appeared to follow familiar rules for such phenomena in dwarf novae, with ...
The X-ray diffraction analysis of (U,Ce)O{sub 2} with the CeO{sub 2} contents ranging from 0 to 20 mol% CeO{sub 2} was performed at room temperature to obtain the variation in the lattice parameter with the CeO{sub 2} content. Ultrasonic pulse echo measurements were also carried out to estimate the change in the mechanical properties of (U,Ce)O{sub 2} with the CeO{sub 2} content. The lattice parameter of (U,Ce)O{sub 2} was found to decrease with increasing CeO{sub 2} content. The variation in the lattice parameter with the CeO{sub 2} content closely followed the Vegard law. The shear and longitudinal velocities in (U,Ce)O{sub 2} were found to decrease with increasing CeO{sub 2} content. The Young`s and shear moduli, and Poisson`s ratio estimated from the wave velocities decreased with the CeO{sub 2} content. No mechanical property showed anomaly in low CeO{sub 2} content region. (orig.).
Glasses in the system (95-x) [0.25 Na2O-0.75 B2O3]-x P2O5-5 Fe2O3 (0?x?15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P2O5 on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P2O5. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P2O5 content as a second network former. These results are interpreted in terms of the replacement of the diborate units with B-O-B bridges by phosphate units with non-bridging oxygens (NBOs). Therefore, ...
The cold-worked Zr-2.5%Nb alloy is used as material for the pressure tubes in CANDU nuclear reactors. During the service life in reactor, diffusion of hydrogen and/or deuterium in the pressure tubes wall occur. Below a certain temperature, a stable hydride of zirconium is formed, as a brittle phase which can lead to catastrophic failures. For this reason, it is very important to be able to investigate the hydrogen effect on the micro structural properties of zirconium alloys. In the present paper a non-destructive testing technique is used, known as ultrasonic spectral analysis. When an ultrasonic signal traverses a medium, the frequency components associated with the input signal are altered. By frequency analysing the reflected signals, it is possible to study and compare the material properties. The two major parameters measured in ultrasonic spectroscopy are the attenuation and the velocity of the waves. Attenuation is determined by the energy losses in compressions and ...
A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...
Continuous metallic glass ribbons were produced by mejans of liquid-quenching at rates >10/sup 50/C/s. The ribbons, typically 30 ..mu..m thick and 1 to 2 mm wide, were determined to be glassy by X-ray diffraction (XRD) employing CuK..cap alpha.. and MoK..cap alpha.. radiation. Mechanical properties of the as-quenched product were determined by measurements of hardness, tensile strength and Young's modulus. The Vicker's diamond pyramid microhardness (H/sub V/) was measured on epoxy mounted samples using a Lietz Miniload instrument with a 100 g load. Tensile tests were conducted in an Instron machine using specimens which were hand-polished to produce smooth, parallel sides. Young's modulus (E) is given by the relationship rho V/sub E/sup 2//. V/sub E/, the velocity of extensional mode waves, was measured by the pulse-echo technique using a Panametrics Intervalometer and glass density, rho, was obtained by the liquid immersion method. ...
This document gathers a series of very short articles concerning nuclear industry around the world. Areva company is investing 30 million euros in its Chalon-Saint-Marcel plant, it is the consequence of the extension of service life of nuclear power plants in the Usa. Areva holds 40% of the American market concerning the replacement of steam generators and 50% of that concerning the replacement of closure heads. The Obrigheim nuclear power plant was definitely closed down on may 2004, this decommissioning is a step forward in the German policy of progressively stepping out of nuclear energy. Chinese authorities are willing to construct 40 nuclear reactors in 15 years, despite that, the contribution of nuclear energy to the generation of electricity will reach only 4% in 2020. In 2007 Cea will begin the construction works of a new research reactor (Jules Horowitz reactor) in the Cadarache site. Prices of the yellow cake have been going up during the last years: from 9 dollar the pound ...
Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...
The mining and energy industry is under assault today for reasons that have less to do with alleged technical failures and much more to do with ethical complaints about a rate of growth in population that industrial products from mining resources have made possible. The political agendas of Western industrialized nations have been driven during the past quarter century by those whose social philosophy advocates a new ethic of biocentric equality, whereby humans must be forced to being `living as if Nature mattered`. A Green ethic requires that `a violent, plundering humankind` must abandon its alleged rape of the earth and derive its ethical norms from pre-existing ecosystemic harmonies to preserve a fragile and precarious balance existing in Nature. From the perspective of history, there is nothing new about such complaints, current complaints about the use of fossil fuels and pollution from mining, echo similar complaints in past periods. Current Green thinking ...
MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T[sub 1] weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of examination for hypophyseal tumours to ...
MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T_1 weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is recommended as a method of examination for hypophyseal tumours to ...
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor invasion ...
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were different from those obtained for the artificially defected tube. In UT ...
A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for systems with shift-variant ...
Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted ...
The study described in this report is part of a project sponsored by the Toronto Atmospheric Fund, performed at the Lawrence Berkeley National Laboratory, to assess the potential role of surface property modifications on energy, meteorology, and air quality in the Greater Toronto Area (GTA), Canada. Numerical models were used to establish the possible meteorological and ozone air-quality impacts of increased urban albedo and vegetative fraction, i.e., ''cool-city'' strategies that can mitigate the urban heat island (UHI), significantly reduce urban energy consumption, and improve thermal comfort, particularly during periods of hot weather in summer. Mitigation is even more important during critical heat wave periods with possible increased heat-related hospitalization and mortality. The evidence suggests that on an annual basis cool-city strategies are beneficial, and the implementation of such measures is currently being investigated in the U.S. and ...
Full text: Thermoluminescence (TL) is a phenomenon of light emission caused by heating a pre-irradiated material. When ionizing radiation hits a TL material, electrons are freed from some atoms and moved in the material, leaving behind 'holes' of positive charge. Subsequently when the TL material is heated, the electrons and the 'holes' re-combine, and release the extra energy in the form of light. The light intensity can be measured, and related to the amount of energy initially absorbed through exposure to the ionizing radiation. In nineteen sixties thermoluminescence dosimeters (TLD) became popular for dosimetric applications in view of their small size, sensitivity and accuracy. Consequently, in early seventies, several countries started adopting of TLD for personnel monitoring. The idea of introducing TLD to replace the then prevalent film dosimeter for personnel monitoring in India was mooted and successfully implemented by Dr. K G Vohra. Limitations of prevalent film dosimeters ...
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity variation with repetition and T1 relaxation time ...
Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse ...
The temperature dependent vibrational relaxation of the CO stretching mode of Rhodium dicarbonyl acetylacetonate (Rh(CO){sub 2}(acac)) and tungsten hexacarbonyl (W(CO){sub 6}) in dibutylphthalate (DBP) and 2-methylpentane (2-MP) were measured with IR pump and probe (P-P) experiments. The experiments were performed with {approximately}1.5 ps pulses generated by the Stanford superconducting accelerator pumped free electron laser (FEL). Measurements were performed on the Rh(CO){sub 2}(acac) CO asymmetric stretching mode at {lambda} = 4.98{mu}m from 10 K to 300 K. Both the parallel and magic angle probe polarizations decay curves are biexponential over the entire temperature range. The slow component (ranging from 40 ps at 300 K to 55 ps at 10K) is attributed to the population relaxations. For the fast component (ranging from 4-5 ps at 300 K to 13-15 ps at 10K), we propose a mechanism of spectral diffusion, in contrast to the previously proposed mechanisms of scattering between closely ...
Glasses in the system (95-x) [0.25 Na{sub 2}O-0.75 B{sub 2}O{sub 3}]-x P{sub 2}O{sub 5}-5 Fe{sub 2}O{sub 3} (0<=x<=15 mol%), have been prepared by the melt quenching technique. Elastic properties and FT-IR spectroscopic studies have been employed to study the role of P{sub 2}O{sub 5} on the structure of the glass system. Elastic properties Poisson's ratio, micro-hardness and Debye temperature have been investigated using sound wave velocity measurements at 4 MHz (both longitudinal and shear) at room temperature. The results showed that the density and the molar volume increase as both sound velocities and the determined glass transition temperatures decrease with increasing the contents of P{sub 2}O{sub 5}. Infrared spectra of the glasses reveal that the borate network consists of diborate units and is affected by the increase in the concentration of P{sub 2}O{sub 5} content as a second network former. These results are interpreted in terms of the replacement of ...
In transfusion-dependent {beta}-thalassemia major, increased iron deposition in the pituitary gland has a cytotoxic effect leading mainly to hypogonadotropic hypogonadism. Our purpose was to assess in these patients the height of the pituitary gland and to evaluate whether it represents a marker of pituitary gland function. In 29 patients with {beta}-thalassemia major and 35 age- and gender-matched controls the pituitary gland height was evaluated in a midline sagittal scan using a spin echo T1-weighted (500/20 TR/TE) sequence. In all patients, an extensive endocrine evaluation was performed, including measurements of spontaneous and stimulated levels of gonadotropins, thyroid hormones, growth hormone, insulin-like growth factor, and adrenal hormones. The pituitary gland height was lower in thalassemic patients with hypogonadotropic hypogonadism (n=15) (mean 3.48; SD 0.46) than in the age- and gender-matched controls (mean 6.29; SD 0.77), (P<0.001). No ...
Magnetic resonance (MR) imaging was performed in 26 patients with Ewing's sarcoma of bone preceding and following neoadjuvant chemotherapy, to assess tumour response non-invasively prior to surgery. T1- and T2-weighted spin echo images were obtained. Changes including intra- and extramedullary signal intensities, tumour demarcation, tumour volume and the appearance of residual extramedullary tumour were compared with histophathology of the resected specimens. Reduction of tumour volume was significantly higher in good responders. Other single parameters did not correlated with histologic tumour response. However, when several MR parameters summarized in a classification system were combined, a positive correlation with histopathologic response was found. A limited decrease of tumour volume (<25 %) and/or residual soft tissue mass following chemotherapy correlated with a poor response. An inhomogeneous, well-defined cuff of abnormal tissue encircling the bone ...
The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent vascular lumen within ...
56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T{sub 1}w-SE and T{sub 2}w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [Deutsch] 56 Patienten wurden mit der klinischen Diagnose einer frischen Supinationsverletzung des oberen Sprunggelenkes untersucht. Das Lig. talofibulare anterius (TFA) und ...
Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median MRI slice was rated on a score of 0-3. A maximum score of 18 ...
The evaluation of possible manufacture-based defects in turbine shafts and housings for component serviceability relevance is of particular interest not only in post-manufacturing NDT but also in evaluation of NDT results obtained by in-service inspections of components with long service lives. The results discussed in the paper are summarized as follows: Most of the examined natural defects in the forgings and castings behave like cracks under the simulated operating conditions and hence may well be evaluated by fracture mechanical methods for their serviceability relevance determined by crack propagation under fatigue, creep and creep-fatigue stress. The empirical correlation of true defect size and US testing results (echo signal, echodynamics, attenuation) permits improved determination of true defect sizes in the turbine components. Care has to be taken to select the proper testing and evaluation methods in compliance with defect types. (orig./MM) [Deutsch] ...
Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a thrombosed one) at the graft level. In one case MRI was repeated ...
Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted images. As for lesions ...
To investigate the pattern of normal white-matter maturation as demonstrated by high-field-strength MR imaging, 82 normal infants were examined using a 1.5-T unit with spin-echo T1-weighted and T2-weighted pulse sequences. The infants ranged in age from 4 days to 2 years. The scans were assessed for qualitative changes of white matter relative to gray matter and correlated with the patient's age in 14 anatomic areas of the brain. The MR images showed that changes of brain maturation occur in an orderly manner, commencing in the brain stem and progressing to the cerebellum and the cerebrum. Changes from brain myelination were seen earlier on T1-weighted images than on T2-weighted images, possibly because of T1 shortening by the components of the developing myelin sheaths. The later changes on the T2-weighted images correlated best with the development of myelination, as demonstrated by histochemical methods. T1-weighted images were most useful to monitor normal ...
This report seeks to address the role of hydrogen bonding with Bronsted acids and bases in proton-coupled electron transfer (PCET) as it pertains to concerted or stepwise pathways of quinone (Q) and hydroquinone (QH_2) electrochemistry. This study was performed using a series of techniques that included cyclic voltammetry (CV), digital simulations, computational chemistry and "1H NMR. Hydrogen bonding was inferred by a decrease in diffusion coefficient (D) values measured using a pulsed gradient echo- (PGE-) "1H NMR technique. Changes of 40.8% and 37.9% in D values were only noted after the addition of two equivalents of acetate to 1,4-hydroquinone (1,4-QH_2) and catechol (1,2-QH_2), respectively. In contrast, the D values for the addition of selected amines (pyridine, N,N-diisopropylethylamine and triethylamine) changed only 3.2% on average. Quantum mechanical calculations were conducted to determine the pK_a of all quinoid species to serve as a starting point for ...
Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv ...
Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis (T2w-images), atrophy (T2w-TSE or ...
Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an evaluation of the visibility of the tip of the stent-catheter and ...
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and ...
Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those seen on DSA images. The ...
Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor ...
Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and ...
Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained of this region. Finally T1-weighted ...