WorldWideScience
 
 
1

ECCS integrated test in TAPP-3 and 4  

International Nuclear Information System (INIS)

Emergency Core Cooling System (ECCS) is a safety critical system provided to mitigate the consequence of Loss of Coolant Accident (LOCA) in PHWR. Unlike 220MWe, all header injection has been introduced in 540MWe to simplify the logic. ECCS Integrated Test is schematic approach to establish that ECC system will behave as per design intent during actual LOCA condition. Objective of ECCS Integrated test is to ascertain that various ECC system components operate as intended in design. Additionally, the various system resistances which form the input to LOCA analysis are validated. This test has been carried out by creating actual LOCA during cold and pressurised condition of PHT system to establish all phases of injection with overlap. This paper discusses the results obtained during the Integrated Test and comparison with the prediction during the commissioning of first unit of 540 ...

2006-11-13

2

Averting problems caused by solutions  

International Nuclear Information System (INIS)

A brief overview is given of a report on Emergency Core Cooling Systems (ECCS) Recirculation Reliability Knowledge Base compiled by the International Working Group on ECCS Reliability for the OECD/NEA/CSNI. Four safety issues are identified which arise in the context of loss of coolant accidents (LOCAs) and are connected with materials and/or processes that interfere with the ECCS safety function in ways other than just strainer head loss generation. They are: the generation of missiles during a LOCA from encapsulated insulation materials used to reduce insulation debris production; clogging of BWR pressure suppression containment vent pipes by insulation jackets or metallic insulation foil pieces; strainer or sump debris ingestion and the effects of ingested debris on ECCS equipment and core cooling; miscellaneous items such as material aging and self-cleaning strainer concepts. The emphasis is mainly ...

3

Impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Herein we present an impact of diagnosis by enhanced multidetector-row computed tomography and magnetic resonance imaging for extrahepatic cholangiocarcinoma (ECC). Although the diagnosis against the longitudinal stromal extension and surrounding tissue invasion of ECC by multi detector row CT (MDCT) and MRI was very strict, we could not detect any superficial mucosal spread (SMS). Furthermore, the diagnosis of lymphnode metastasis by MDCT/MRI was miserable. We believe that misdiagnosis of SMS is permissible since positive mucosal but not stromal surgical margin was not a significant factor influencing the postoperative prognosis. However, further advances in imaging diagnosis for ECC is needed. (author)

2009-10-01

4

Sensitivity Study for CFD Analysis on Debris Transport to ECCS Sump for CANDU Type Plant in Korea  

International Nuclear Information System (INIS)

Once containment recirculation pumps are activated and emergency core cooling (ECC) flow is supplied from the recirculation sump during loss of coolant accident (LOCA), various insulations and coatings on a pipe, equipments and structures damaged by LOCA break jet as well as additional debris sources are transported to recirculation sump screen by the break flow and containment spray flow drainage. This debris may result in loss of net pressure suction head (NPSH) of the recirculation pumps, and have a threat to long term cooling and containment heat removal capacity. In this case, flow patterns of containment pool are important to confirm behaviors of debris transport for predicting various flow paths to the recirculation sump screen. In this paper, models using commercial computational fluid dynamics (CFD) software CFX are developed for containment pool simulation during recirculation mode. The specific plant used for this analysis is CANDU type plant, in Korea

2010-10-01

5

Integral severe accident analysis of light water nuclear power plants by IMPACT-SAMPSON code  

Energy Technology Data Exchange (ETDEWEB)

The NUclear Power Engineering Corporation (NUPEC) has developed IMPACT-SAMPSON code to analyze integral behavior of light water nuclear power plants under severe accident conditions. IMPACT-SAMPSON's distinguishing features include interconnected hierarchical modules and mechanistic models covering a wide spectrum of scenarios ranging from normal operation to severe accident events, and high-speed simulation on parallel processing computers. The integral plant behaviors of typical PWR and BWR under severe accident conditions have been analyzed with the IMPACT-SAMPSON code. The PWR plant analyzed was the three-loop, steel-dry containment type with 2,440 MWt. The AE accident scenario was supposed, that is, LOCA by 6-inch hot leg failure followed by accumulated water injection, but no ECCS and containment spray activation. The BWR plant analyzed was the 3,293 MWt BWR-5, Mark-II containment type. The TQUV accident scenario was supposed, that is, reactor scram ...

2003-07-01

6

GDH pipe break transient analysis of the RBMK - 1500.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. The cases of GDH impact on an adjacent GDH and its attached piping are investigated in this paper. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material characteristics. The results of the study indicate that a whipping GDH pipe would ...

2002-05-15

7

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina nuclear power plant.  

Energy Technology Data Exchange (ETDEWEB)

Presented in this paper is the transient analysis of a Group Distribution Header (GDH) following a guillotine break at the end of the header. The GDH is the most important component of reactor safety in case of accidents. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the GDH into the ECCS. The GDH that is propelled into motion after a guillotine break can impact neighboring GDH pipes or the nearest wall of the compartment. Therefore, two cases are investigated: GDH impact on an adjacent GDH and its attached piping; and GDH impact on an adjacent reinforced concrete wall. A whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is modeled using finite elements. The finite element code NEPTUNE used in this study enables a dynamic pipe whip structural analysis that accommodates large displacements and nonlinear material characteristics. The results ...

2002-02-26

8

LOBI/B-R1M, Loop for Blowdown Investigation, PWR Single-Ended Cold-Leg Break Experiment B EXP.B  

International Nuclear Information System (INIS)

1 - Description of test facility: The LOBI facility is a 1/700 scale model of a four loop PWR and has two primary loops, the intact loop representing three loops and the broken loop representing one loop of a four-loop PWR. The reactor pressure vessel model contains an electrically heated rod-bundle with 64 rods and a heated length of 3.9 m. The nominal heating power is 5.3 MW. The downcomer is of annular shape. An upper head simulator is connected to the vessel. Each of the two primary loops contains a pump and a steam generator. The different mass flows in the loops are established by the pump speeds, since the two pumps are identical. Heat is removed from the steam generators by a secondary system. ECC water can be supplied from two accumulators, one for each loop. Cold or hot leg as well as combined injection can be simulated. The LOBI test facility is the only high pressure integral test facility within the European Communities (1982), built and operated in ...

9

A study to develop the domestic functional requirements of the specific safety systems of CANDU  

Energy Technology Data Exchange (ETDEWEB)

The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SDS-1, SDS2, ECCS, and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.

2003-03-15

10

A study to develop the domestic functional requirements of the specific safety systems of CANDU  

Energy Technology Data Exchange (ETDEWEB)

The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SOS-1, SOS-2, ECCS and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.

2001-03-15

11

Improvements to the RELAP5/MOD3 reflood model and uncertainty quantification of reflood peak clad temperature  

Energy Technology Data Exchange (ETDEWEB)

This research aims to develop reliable, advanced system thermal-hydraulic computer code and to quantify the uncertainties of code to introduce the best estimate methodology of ECCS for LBLOCA. Although the one of best estimate code, RELAP5/MOD3.1 was introduced from USNRC, several deficiencies in its reflood model and some improvements have been made. The improvements consist of modification of reflood wall heat transfer package and adjusting the drop size in dispersed flow regime. The tome smoothing of wall vaporization and level tracking model are also added to eliminate the pressure spike and level oscillation. For the verification of improved model and quantification of associated uncertainty, the FLECHT-SEASET data were used and upper limit of uncertainty at 95% confidence level is evaluated. (Author) 30 refs., 49 figs., 2 tabs.

1994-06-01

12

Containment temperature, pressure and activity release during limiting design basis accident in TAPP 3 and 4 reactor  

International Nuclear Information System (INIS)

Containment is considered as ultimate safety system and is designed to enclose whole reactor system and prevent the spread of active air-borne fission products. For Pressure and Temperature calculation, Design Basis Accident (Dba) is double ended break of reactor inlet header or main steam line break but activity release studies are done to access its performance following limiting design basis accident i.e. Loss of Coolant Accident (LOCA) and Emergency Core Cooling System (ECCS). In such accident scenario, the core is severely damaged and results in production of steam and hydrogen along with release of activity to containment environment. Containment functions are maintained in such accident, and radiological consequences are within the prescribed limits. (author)

2005-12-01

13

Wolsong 2,3 and 4 fuel channel analysis during a large break loss of coolant accident with loss of ECCS injection  

International Nuclear Information System (INIS)

Wolsong 2,3 and 4 fuel channel analysis during a large break loss of coolant accident with loss of ECCS injection (LOCA/LOECC) is performed to obtain the heat load to moderator. Because the single channel analysis requires the establishment of the safety codes and their input decks, the present study follows the same safety analysis methodology found in FSAR of Wolsong 2,3 and 4. From this work we obtain the safety tools such as CATHENA MOD3.5b/Rev.1 and CHAN-II/A MOD2 codes, and their code modeling in a form of code input deck. The analysis consists of two parts: front-end (blowdown period) and back-end. For the front-end analysis the fuel and pressure tube (PT) temperatures, and PT circumferential strains at the end of front-end as well as fuel channel depressurization are calculated using CATHENA code and used as initial and boundary conditions for back-end analysis. The back-end period under the conditions of prolonged low steam flow is analyzed by CHAN-II code ...

2002-10-01

14

Preliminary test conditions for KNGR SBLOCA DVI ECCS performance test  

Energy Technology Data Exchange (ETDEWEB)

The Korean Next Generation Reactor (KNGR) adopts 4-train Direct Vessel Injection (DVI) configuration and injects the safety injection water directly into the downcomer through the 8.5'' DVI nozzle. Thus, the thermal hydraulic phenomena such as ECCS mixing and bypass are expected to be different from those observed in the cold leg injection. In order to investigate the realistic injection phenomena and modify the analysis code developed in the basis of cold leg injection, thermal hydraulic test with the performance evaluation is required. Preliminarily, the sequence of events and major thermal hydraulic phenomena during the small break LOCA for KNGR are identified from the analysis results calculated by the CEFLASH-4AS/REM. It is shown from the analysis results that the major transient behaviors including the core mixture level are largely affected by the downcomer modeling. Therefore, to investigate the proper thermal hydraulic phenomena occurring ...

1999-03-01

15

Mesenchymal tumors of the pancreas. CT patterns; Tumori mesenchimali del pancreas: aspetti con tomografia computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Purpose of this item is to report the CT patterns of pancreatic mesenchymal lesions and to investigate the capabilities and limitations of this technique in terms of characterization. In selected cases, CT can provide virtually diagnostic information (lipoma and teratoma), or at least highly suggestive findings (NHL, plexiform neurofibroma, lymphangioma). Moreover, knowledge of the variable morphostructural patterns of mesenchymal hisototypes (SCH, Sarcoma etc.) permits to include them in the differential diagnosis of pancreatic masses. [Italian] Scopo di questo rapporto e' descrivere gli aspetti semeiologici dei tumori mesenchimali del pancreas con la TC verificandone le possibilita e i limiti per la caratterizzazione. Pur nella rarita' dei reperti considerati, la TC puo' consentire l'effettiva caratterizzazione in alcuni casi (lipoma, neurofibroma plessiforme, linfangioma) o includere anche istotipi meno comuni (Schwannoma, sarcomi, ...

1999-10-01

16

Evaluation of pipe whip impacts on neighboring piping and walls of the Ignalina Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

Stress corrosion cracks have been discovered in Group Distribution Headers (GDH) at the Ignalina and Chernobyl Nuclear Power Plants. This increases the probability that a guillotine pipe break can occur that creates a whipping pipe (GDH) with the potential to damage surrounding structures-i.e. adjacent GDH and its attached piping or adjacent reinforced concrete compartment wall. The GDH is the most important component for reactor safety in case of an accident. Emergency Core Cooling System (ECCS) piping is connected to the GDH piping such that, during an accident, coolant passes from the ECSS into the GDH. Presented in this paper is the transient analysis of a Group Distribution Header following a guillotine break at the blind end of the header. Using a very conservative force loading function, the transient response of a whipping RBMK-1500 GDH along with neighboring concrete walls and pipelines is obtained using finite element methodology. The results of the ...

2007-04-15

17

Construction of the DIVA(direct vessel injection visualization and analysis test facility) for the LBLOCA of KNGR  

Energy Technology Data Exchange (ETDEWEB)

In this report, the descriptions of the DIVA test facility and those test matrixes are presented. The test sections simulate the downcomer annulus of DVI system with various scalling methodologies. The UPTF one has 1/7.5 scale and the APR-1400 test sections are reduced in 1/7 scale and 1/5 scale respectively. Also, the instrumentations, measuring methods are described. The major measuring parameters are ECC injection rate, air injection rate, bypass fraction, system pressure and so on. And finally, the operation procedure and experimental steps are introduced. From the DIVA tests, the multi-dimensional behaviors of two-phase flow in the downcomer during the reflood phase can be investigated using a transparent test facility. Also comparing the experimental data which are performed in various scale downcomer, it is expected that some criteria of scalling methodology proper to the DVI system can be derived. 10 refs., 19 figs., 10 tabs. (Author)

2002-03-01

18

TRANSPORT CHARACTERISTICS OF REPRESENTATIVE DEBRIS IN A OPEN CHANNEL  

Energy Technology Data Exchange (ETDEWEB)

During LOCA(Loss of Coolant Accident), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris could be accumulated and be clogged in the recirculation sump screen. If debris blocked the sump screen, the pressure drop increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR at 1990. Considering the important of safety, US NRC published Regulatory Guide 1.82 Rev.3 incorporating the R and D findings and ...

2010-05-15

19

Sump Pool Flow Simulation during Fill-up Phase of LOCA Using on CFD for OPR1000 Plant  

Energy Technology Data Exchange (ETDEWEB)

During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR of USA and Sweden. Considering the important to safety, US NRC ...

2009-10-15

20

Analysis of load-penetration depth data using Oliver-Pharr and Cheng-Cheng methods of SiAlON-ZrO_2 ceramics  

International Nuclear Information System (INIS)

Depth sensing indentation tests were carried out to obtain load-penetration depth curves of SiAlON-ZrO_2 ceramics under different peak loads ranging from 200 to 1800 mN. The values of indentation hardness (H_O_P, H_C_C) and reduced elastic modulus (E_O_P, E_C_C) were calculated by using Oliver-Pharr (OP) and Cheng-Cheng (CC) methods. The experimental results revealed that the indentation hardness and reduced elastic modulus exhibit peak-load dependence, i.e. indentation size effect. Both indentation hardness and reduced elastic modulus values were obtained by considering indenter tip roundness and machine compliance. These values obtained from the OP method are higher than from the CC method. On the other hand, h_f/h_m ratios were used to clarify the indentation deformation behaviour of the SiAlON-ZrO_2 ceramic. The experimental h_f/h_m values were lower than the reported critical value (0.7) for all applied test loads, which is attributed to work-hardening ...

2008-02-07

 
 
 
 
21

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the charcoal and heat is generated. The part of gamma radiations ...

2006-11-13

22

Verification of the CFD code FLUENT by post test calculation of ROCOM experiments  

International Nuclear Information System (INIS)

Full text of publication follows: The TUV NORD e.V. is an independent Technical Support Organisation (TSO) performing safety assessments in almost every field of technology. In nuclear safety the TUV can look back on more than 40 years of experience. In the last years in Germany PWR safety analyses were focussed on boron dilution events with the potential of reactivity transients. The possibility of coolant with a low boron concentration collected in localized areas of the reactor coolant system (RCS) can be caused by injection of coolant with less boron content from interfacing systems (external dilution) as well as separation of borated reactor coolant into highly concentrated and diluted fractions (inherent dilution). Inherent dilution can e.g. occur after reflux-condenser heat transfer after a small break loss of coolant accident (SBLOCA) with a limited operability of the emergency core cooling (ECC) systems. The TUV Nord e.V. was charged by German supervisory ...

2005-10-02