Energy Technology Data Exchange (ETDEWEB)
The feasibility of self-expanding nitinol stents for treatment of infragenicular arteries following unsuccessful balloon angioplasty was assessed. Options for lower limb percutaneous revascularization are limited, especially for complex vessel obstruction. Depending on the lesion and the experience of the interventionalist, the failure rate of balloon angioplasty (PTA) ranges between 10 and 40%. Until recently, no self-expanding stent for the use in the infragenicular arteries was available. This is the first report of the results for 18 consecutive patients who received 4F sheath compatible self-expanding nitinol stents following unsuccessful PTA or early restenosis. Twenty-four stents were implanted in 21 lesions for various indications residual stenosis >50% due to heavy calcification, flow-limiting dissection, occluding thrombus resistant to thrombolyis, thrombaspiration, and PTA, and early restenosis after ...
2007-08-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an ...
1998-03-01
UK PubMed Central (United Kingdom)
The resistance to destruction of spores of Bacillus subtilis var. niger occluded in crystals of calcium carbonate and exposed to ethylene oxide and moist and dry heat...Full Text Available
1967-07-01
UK PubMed Central (United Kingdom)
BackgroundWe examined the effects of short-term consumption of whey protein isolate on muscle proteins and force recovery after eccentrically-induced muscle damage in healthy individuals.MethodsSeventeen...Full Text Available
Concentric Versus Enhanced Eccentric Hamstring Strength Training: Clinical Implications
UK PubMed Central (United Kingdom)
Objective: Hamstring injuries can be quite debilitating and often result in chronic problems. Eccentric muscle actions are often the last line of defense against muscle injury...Full Text Available
1998-07-01
On the orbital evolution and growth of protoplanets embedded in a gaseous disc
We present a new computation of the linear tidal interaction of a protoplanetary core with a thin gaseous disc in which it is fully embedded. For the first time a discussion of the orbital evolution of cores with eccentricity (e) significantly larger than the gas-disc scale height to radius ratio (H/r) is given. We find that the direction of orbital migration reverses for e>1.1H/r. This occurs as a result of the orbital crossing of resonances in the disc that do not overlap the orbit when the eccentricity is very small. Simple expressions giving approximate fits to the eccentricity damping rate and the orbital migration rate are presented. We go on to calculate the rate of increase of the mean eccentricity for a system of protoplanetary cores due to dynamical relaxation. By equating the eccentricity damping time-scale with the dynamical relaxation time-scale we deduce that an ...
1999-01-01
Eccentric conical fastening system
Energy Technology Data Exchange (ETDEWEB)
Fastening systems for parts that endure high vibration shear loads have traditionally been difficult or expensive to produce. This application describes a fastening system with multiple conical surfaces and eccentric offsets. The novel conical fastener system allows parts to be assembled with reduced tolerance controls at interface features while improving alignment precision. The eccentric conical fastening system is particularly well suited for assemblies with high shear loads in high vibration/shock environments, and/or for systems that have extremely precise pointing requirements.
2008-11-25
International Nuclear Information System (INIS)
In a cold fusion method by electrolysis, a hydrogen occluding material mainly comprising vanadium is used as a material for a negative electrode, and lithium isotopes are incorporated in the material by more than 93%. That is, the ratio of lithium 7 ("7Li) isotope is increased to higher than the natural existent ratio, so that tritium ("3H) concentration in the hydrogen occluding material can be increased, to attain energy at high efficiency. (T.M.).
1993-03-02
Enhanced Biocompatibility of Porous Nitinol
UK PubMed Central (United Kingdom)
Porous Nitinol (PNT) has found vast applications in the medical industry as interbody fusion devices, synthetic bone grafts, etc. However, the tendency of the PNT to corrode is anticipated to...Full Text Available
2009-08-01
Covered nitinol stents for the treatment of esophageal strictures and leaks
UK PubMed Central (United Kingdom)
AIM: To compare 2 different types of covered esophageal nitinol stents (Ultraflex and Choostent) in terms of efficacy, complications, and long-term outcome.METHODS: A retrospective review of...Full Text Available
2010-05-14
A newly designed big cup nitinol stent for gastric outlet obstruction
UK PubMed Central (United Kingdom)
AIM: To find out whether a newly designed big cup nitinol stent is suitable for treatment of patients with gastric outlet obstruction resulting from gastric cancer.METHODS: The new stent is composed...Full Text Available
2010-09-07
International Nuclear Information System (INIS)
The rapid circularization and synchronization of the stellar components in an eccentric binary system at the onset of Roche lobe overflow is a fundamental assumption common to all binary stellar evolution and population synthesis codes, even though the validity of this assumption is questionable both theoretically and observationally. Here we calculate the evolution of the orbital elements of an eccentric binary through the direct three-body integration of a massive particle ejected through the inner Lagrangian point of the donor star at periastron. The trajectory of this particle leads to three possible outcomes: direct accretion onto the companion star within a single orbit, self-accretion back onto the donor star within a single orbit, or a quasi-periodic orbit around the companion star, possibly leading to the formation of a disk. We calculate the secular evolution of the binary orbit in the first two cases and conclude that direct impact ...
2010-11-20
Effects of gradual coronary artery occlusion and exercise training on gene expression in swine heart
UK PubMed Central (United Kingdom)
Gradual occlusion (O) of the swine left circumflex coronary artery (LCX) with an ameroid occluder results in complete O within 3 weeks, collateral vessel development, and compensatory hypertrophy....Full Text Available
2007-01-01
UK PubMed Central (United Kingdom)
The purpose of this study was to determine if there were any beneficial or detrimental effects regarding delayed onset muscle soreness (DOMS), serum creatine kinase (CK), and maximum concentric strength...Full Text Available
1994-12-01
UK PubMed Central (United Kingdom)
ObjectiveWe wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients.Materials...Full Text Available
2011-03-01
The Effect of Heat Treatment and Mechanical Polishing on Nitinol Stent
Energy Technology Data Exchange (ETDEWEB)
To understand the effect of heat treatment and mechanical polishing of a Nitinol wire on the chemical composition and physical morphology of the wire surface. Stents with a diameter of 1.0 cm, length of 8-10 cm, and composed of a Nitinol wire, were heat-treated at 500 .deg. C for 30 minutes, and mechanically polished with walnut shell granules. The wire surface morphology was studied with both an optical and a scanning electron microscope (SEM). In addition, an elemental analysis was performed by Energy Dispersive X-ray spectroscopy (EDX). Long microcracks along the wire direction and short microcracks across the wire were observed by SEM from the raw Nitinol wire. Upon heat treatment, the color of the wire turned blue, and Na, K, Cl, Si, Al atoms were seen from the EDX of the heat treated wire, which were absent in the original wire. The microcracks disappeared with the mechanical polishing, and the Na, K, Cl, Si, Al atoms ...
2009-09-15
Development of linear flow rate control system for eccentric butter-fly valve
Energy Technology Data Exchange (ETDEWEB)
Butter-fly valves are advantageous over gate, globe, plug, and ball valves in a variety of installations, particularly in the large sizes. The purpose of this project development of linear flow rate control system for eccentric butter-fly valve (intelligent butter-fly valve system). The intelligent butter-fly valve system consist of a valve body, micro controller. The micro controller consist of torque control system, pressure censor, worm and worm gear and communication line etc. The characteristics of intelligent butter-fly valve system as follows: Linear flow rate control function. Digital remote control function. guard function. Self-checking function. (author)
1999-12-01
This report describes a technique of inserting an implantable venous access port (portacath) through a thrombosed and occluded vein employing a pre-existing peripherally inserted central catheter (PICC) as the route of access. The PICC was used as a conduit for venous access in a way that has not been described previously in the literature. This procedure was performed in a young patient with cystic fibrosis in an effort to prevent the use of his virgin contralateral veins, which might be used in the future.
2010-02-15
British Library Electronic Table of Contents (United Kingdom)
Ventricular septal defect after acute myocardial infarction (AMI) is a complication associated with poor outcome in the absence of intervention. We report a case of successful TEE guided transcatheter closure of a post myocardial infarction (MI) ventricular septal defect (VSD) with an Amplatzer occluder in a 79 years old male with cardiogenic shock.
2011-01-01
A retrievable nitinol endobronchial stent : an experimental study in dog
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to evaluate the safety and the retrievability of a new covered retrievable nitinol tracheobronchial stent. Stents were knitted from 0.2mm nitinol wire, covered with polyurethane, and were 20-22mm in diameter and 2cm in length. Under fluoroscopic guidance, a stent was placed in the normal right bronchus intermedius of ten dogs. Using a retrieval hook, stent retrieval was attempted after 1 month(N=5) or 2 months(N=5). After removal, the dogs were sacrificed and their their tracheobronchial trees were examined grossly and histologically. Eleven stents were successfully placed in ten dogs. Migration and expectoration occurred in four of ten stents in nine dogs(40%). Five stents were successfully removed from six dogs(83%). Without significant difference between the two groups, mild to moderate mucosal hyperplasia was noted at the sites of stents as well as above and below them. On microscopy, three of five dogs showed ...
1999-06-01
A Covered Nitinol Stent Fracture in a Patient with a Malignant Esophageal Stricture: A Case Report
Energy Technology Data Exchange (ETDEWEB)
Self-expanding metallic stent insertion has been widely applied for the palliative treatment of malignant esophageal strictures. Although it is known as an easy, safe, and effective procedure, complications are well known and include things such as stent migration and esophageal stent occlusion caused by tumor in growth. However, metallic stent fractures have been rarely reported in the esophagus, especially for nitinol stents. We report a case of a stent fracture associated with migration in a patient with a malignant esophageal stricture near the gastroesophageal junction. It is highly probable that the stent fracture was due to chemical erosion of the stent caused by gastric juice
2008-11-15
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment of malignant gastroduodenal obstructions. Two types of expandable nitinol stent were constructed by weaving a single thread of 0.2mm nitinol wire in a tubular configuration: an uncovered stent 18mm in diameter and a covered stent 16mm in diameter. Both ends of the covered stent were fabricated by coaxially inserting the covered stent into the tubular uncovered stent and then attaching the two stents together with using nylon monofilament. Under fluoroscopic guidance, the stent was placed in 29 consecutive patients (20 men and 9 women, mean age: 65 years) who were suffering with malignant gastric outlet obstruction (n=20), duodenal obstruction (n=6) or combined obstruction (n=3). Clinical improvement was assessed by comparing the food intake ...
2005-12-15
Malignant duodenal obstructions: palliative treatment with covered expandable nitinol stent
Energy Technology Data Exchange (ETDEWEB)
To evaluate the feasibility and clinical effectiveness of using a polyurethane-covered expandable nitinol stent in the palliative treatment of malignant duodenal obstruction. Under fluoroscopic guidance, a polyurethane-covered expandable nitinol stent was placed in 12 consecutive patients with malignant duodenal obstructions. All presented with severe nausea and recurrent vomiting. The underlying causes of obstruction were duodenal carcinoma (n=4), pancreatic carcinoma (n=4), gall bladder carcinoma (n=2), distal CBD carcinoma (n=1), and uterine cervical carcinoma (n=1). The sites of obstruction were part I (n=1), part II (n=8), and III (n=3). Due to pre-existing jaundice, eight patients with part II obstructions underwent biliary decompression prior to stent placement. An introducer sheath with a 6-mm outer diameter and stents 16 mm in diameter were employed, and to place the stent, and after-loading technique was used. Stent placement was ...
2002-04-01
Usefulness of thromboaspiration with Desilets-Hoffman sheath in thrombosed hemodialysis access graft
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a Desilets-Hoffman Sheath compared with the previously established percutaneous mechanical thrombectomy technique in cases of occluded dialysis graft. One hundred and sixty eight patients (103 women, 65 men; mean age, 54.7 years; mean graft age, 20.9 months) with 225 episodes of dialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using the crossing catheter or single puncture technique. The technical success rate, procedure time, and complication and patency rates were analyzed. Technical success was achieved in 200 of the 225 procedures (88.9%). The average duration of the intervention was 74.3 {+-} 35 minutes. The primary patency rate was 63.1% at 3 months, 44.2% at 6 months and 26.3% at 1 year. Major complications occurred in 4% of the cases (4 venous ruptures; 4 arterial embolisms; 1 arterial ...
2004-07-01
Opto-acoustic recanilization delivery system
Energy Technology Data Exchange (ETDEWEB)
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the optical fibers into ...
2002-01-01
Comprehensive simulations of superhumps
(Abridged) We use 3D SPH calculations with higher resolution, as well as with more realistic viscosity and sound-speed prescriptions than previous work to examine the eccentric instability which underlies the superhump phenomenon in semi-detached binaries. We illustrate the importance of the two-armed spiral mode in the generation of superhumps. Differential motions in the fluid disc cause converging flows which lead to strong spiral shocks once each superhump cycle. The dissipation associated with these shocks powers the superhump. We compare 2D and 3D results, and conclude that 3D simulations are necessary to faithfully simulate the disc dynamics. We ran our simulations for unprecedented durations, so that an eccentric equilibrium is established except at high mass ratios where the growth rate of the instability is very low. Our improved simulations give a closer match to the observed relationship between superhump period excess and binary ...
2007-01-01
Influence of manufacturing methods on the homogeneity and properties of nitinol tubular stents
Energy Technology Data Exchange (ETDEWEB)
Nitinol has found growing applications in vascular stents, with the recent introduction on the market of a number of new nitinol tubular devices for coronary and peripheral usage. These stents can be produced either through the expansion of a pattern cut on a small tube (pre-cut) or by cutting the deployed design on a tube of a larger size (pre-expanded). The aim of the study was to analyze the differences of properties induced by the two manufacturing methods. For this purpose, differential scanning calorimetry (DSC) measurements were performed on various specimens from the two types of stents. A first set of measurements shows that pre-expanded stents exhibit usual A<->R<->M transformations whereas multi-stage transformations occur for pre-cut stents. Two types of DSC specimens were then prepared for each stent, corresponding to the straight sections and the curved parts of the stent. It is shown that the pre-cut ...
2001-11-01
Energy Technology Data Exchange (ETDEWEB)
To evaluate the efficacy of a paclitaxel-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt. Twelve pigs were used in this study. Two types of 10-mm diameter and 60-mm long nitinol stents were made for a transjugular intrahepatic portosystemic shunt by coating them with a polyurethane solution, with and without paclitaxel. Each transjugular intrahepatic portosystemic shunt was created successfully in the 12 swine with 7 paclitaxel-eluting stents and 5 polyurethane stents. Five swine in each group were followed-up for 14 days due to the death of 2 swine given the paclitaxel-eluting stents. The proliferation of the pseudointima was evaluated on both follow-up portograms and histopathology examinations. The mean maximum pseudointimal hyperplasia is expressed as the percentage of the stent radius. On the portograms, all the transjugular intrahepatic portosystemic shunts using the ...
2007-03-15
The use of SMARTeR stents in patients with biliary obstruction
Energy Technology Data Exchange (ETDEWEB)
AIM: The purpose of the study was to evaluate the percutaneous use of the new nitinol SMARTeR stents in patients with biliary obstruction. MATERIALS AND METHODS: Four stents were placed in three patients percutaneously under ultrasound and fluoroscopic guidance. RESULTS: The deployment of the stents was successful in all three patients. All stents maintained their patency and position after short-term follow-up. CONCLUSION: The nitinol SMARTeR stent is useful in the management of patients with biliary obstruction although accurate placement across the ampulla was found to be technically more difficult than with the Wallstent. Larger, long-term follow-up studies are required to evaluate the long-term patency of these new devices.
2004-03-01
Mechanical stability of the diamond-like carbon film on nitinol vascular stents under cyclic loading
Energy Technology Data Exchange (ETDEWEB)
The mechanical stability of diamond-like carbon (DLC) films coated on nitinol vascular stents was investigated under cyclic loading condition by employing a stent crimping system. DLC films were coated on the vascular stent of a three dimensional structure by using a hybrid ion beam system with rotating jig. The cracking or delamination of the DLC coating occurred dominantly near the hinge connecting the V-shaped segments of the stent where the maximum strain was induced by a cyclic loading of contraction and extension. However the failures were significantly suppressed as the amorphous Si (a-Si) buffer layer thickness increased. Interfacial adhesion strength was estimated from the spalled crack size in the DLC coating for various values of the a-Si buffer layer thickness.
2008-12-01
Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent
Energy Technology Data Exchange (ETDEWEB)
We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. Thirty-seven patients with common bile duct strictures caused by malignant disease were treated by placing a total of 37 nitinol PTFE stents. These stents were covered with PTFE with the exception of the last 5 mm at each end; the stent had an unconstrained diameter of 10 mm and a total length of 50 80 mm. The patient survival rate and stent patency rate were calculated by performing Kaplan-Meier survival analysis. The bilirubin, serum amylase and lipase levels before and after stent placement were measured and then compared using a Wilcoxon signed-rank test. The average follow-up duration was 27.9 weeks (range: 2 81 weeks). Placement was successful in all cases. Seventy-six percent of the patients (28/37) experienced adequate palliative drainage for the remainder of ...
2007-10-15
Energy Technology Data Exchange (ETDEWEB)
We wanted to determine the technical and clinical efficacy of placing a self-expandable PTFE-covered nitinol stent for the management of inoperable malignant biliary obstruction. Thirty six patients with inoperable malignant biliary obstructions were treated by placement of self-expandable PTFE-covered nitinol stents (S and G Biotech Corporation, Seongnam, Korea). Clinical evaluation was done with assessment of the serum bilirubin and alkaline phosphatase levels, which were measured before and after stent placement within 1 week, at 1 month and at 3 months. The patient survival rate and stent patency rate were calculated with performing Kaplan-Meier survival analysis. Successful stent placement was achieved in all the patients without procedure-related complication. Pancreatitis as an early complication occurred in two cases. The serum bilirubin and alkaline phosphatase levels were significantly decreased after the procedure. During the ...
2008-06-15
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent ...
2005-03-01
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the long-term results of a dual expandable nitinol stent for the palliative treatment of malignant gastroduodenal strictures. The dual stent consists of two stents; an outer partially nylon covered stent and an inner bare nitinol stent. The outer stent was placed into the stricture and this was followed by coaxial placement of the inner bare stent. Using fluoroscopic guidance, dual expandable stents were placed in 86 patients with inoperable malignant gastroduodenal strictures. The technical and clinical success, the complication, survival and the stent patency were evaluated during the follow-up period. Stent placement was technically successful in 83 of the 86 patients. After stent placement, 74 of the 85 patients showed improvement of their symptoms. During the mean follow-up period of 133 days, 24 patients (28%) developed recurrent symptoms due to incomplete expansion (n=1), stent migration (n=4), food impaction (n=2), ...
2009-12-15
Parallel architecture for rapid image generation and analysis
Energy Technology Data Exchange (ETDEWEB)
A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the architecture has the ability to decompose images.
1987-01-01
Clinical Evaluation of the Zilver Vascular Stent for Symptomatic Iliac Artery Disease
British Library Electronic Table of Contents (United Kingdom)
PurposeTo evaluate the safety and effectiveness of the Zilver vascular stent in the treatment of de novo or restenotic lesions in the external and common iliac arteries.Materials and MethodsRegardless of the results of an initial percutaneous transluminal angioplasty (PTA), 151 consecutive patients were implanted with Zilver vascular stents (Cook, Bloomington, Ind) in up to two stenotic (?10 cm) or occluded (?5 cm) atherosclerotic lesions of the external or common iliac arteries. The primary endpoint was the rate of major adverse events within 9 months after the procedure. Major adverse events were defined as death, myocardial infarction, target lesion revascularization, and limb loss. Secondary endpoints included acute procedural success, 30-day clinical success, 9-month pat...
2008-01-01
We assess the accuracy and relevance of the numerical algorithms based on the principles of Geometrical Optics (GO) and Physical Optics (PO) in the analysis of reduced-size homogeneous dielectric lenses prone to behave as open resonators. As a benchmark solution, we use the Muller boundary integral equations discretized with trigonometric Galerkin scheme that has guaranteed and fast convergence as well as controllable accuracy. The lens cross-section is chosen typical for practical applications, namely an extended hemiellipse whose eccentricity satisfies the GO focusing condition. The analysis concerns homogeneous lenses made of rexolite, fused quartz, and silicon with the size varying between 3 and 20 wavelengths in free space. We consider the 2-D case with both E- and H-polarized plane waves under normal and oblique incidence, and compare characteristics of the near fields.
2010-01-01
SPH simulations of accretion flow via Roche lobe overflow and via mass transfer from Be disk
We compare the accretion flow onto the neutron star induced by Roche lobe overflow with that by the overflow from the Be disk, in a zero eccentricity, short period binary with the same mass transfer rate, performing three-dimensional Smoothed Particle Hydrodynamics simulations. We find that a persistent accretion disk is formed around the neutron star in both cases. The circularization radius of the material transferred via Roche lobe overflow is larger than that of the material transfered from the Be disk. Thus, the growth of the accretion disk in the former case becomes significantly slower than in the latter case. In both cases, the mass accretion rate is very small and varies little with orbital phase, which is consistent with the observed X-ray behaviour of Be/X-ray binaries with circular orbits (e.g. XTE J1543-568).
2005-01-01
DEFF Research Database (Denmark)
Oscillating stars in binary systems are among the most interesting stellar laboratories, as these can provide information on the stellar parameters and stellar internal structures. Here we present a red giant with solar-like oscillations in an eclipsing binary observed with the NASA Kepler satellite. We compute stellar parameters of the red giant from spectra and the asteroseismic mass and radius from the oscillations. Although only one eclipse has been observed so far, we can already determine that the secondary is a main-sequence F star in an eccentric orbit with a semi-major axis larger than 0.5 AU and orbital period longer than 75 days.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
To assess the influence of stent design [interlacing (type A) vs. crossing method (type B)] on neointimal hyperplasia using a self-expandable nitinol stent, which crosses the side branches of the abdominal aorta. In seven mongrel dogs, nitinol stents with type A and B intersections were placed in the abdominal aorta across the main branches: 4 Niti-Ms and 3 Niti-Ds. Two months after the stent placement, a DSA was performed for a stent patency evaluation, followed by the extraction of the aortas. The degree of neointimal formation along the wire was evaluated by calculating the area ratio of intimal hyperplasia (type A vs. B). A Student's t-test was employed to investigate the differences in the neointimal hyperplasia between blood types A and B. The total number of wire intersections overlain at the ostia branch ostia was 23 for type A and 36 for type B. The area ratio of the neointimal hyperplasia, for a given area, was 29.09 {+-} ...
2008-05-15
Mapping Strain in Nanocrystalline Nitinol: an X-ray Diffraction Method (SULI paper)
Energy Technology Data Exchange (ETDEWEB)
Understanding the mechanical properties of biomedical devices is critical in predicting and preventing their failure in the body. Such knowledge is essential, for example, in the design of biomedical stents, which must undergo repeated strain over their ten year lifetimes without breaking. Computational models are used to predict mechanical response of a device, but these models are not complete; there are significant deviations from the predictions, especially when devices are subjected to repeated multi-axial loads. Improving these models requires comparisons with actual measurements of strained nitinol. Local measurements of the full strain tensor can be made using X-ray diffraction techniques, but they are currently limited to materials whose grain size is larger than the X-ray beam size or require several diffraction patterns produced by rotation of the sample. Nitinol stents are nanocrystalline, with grains smaller than any available ...
2006-01-04
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the initial and mid-term results of a new self-expanding low strut profile nitinol stent for treatment of atherosclerotic lesions stenoses and occlusions in the superficial femoral artery (SFA). Materials and Methods: In 8 patients (4 male, 4 female, mean age 74.8 {+-} 8.8 years) with SFA lesions and non-satisfying results after PTA treatment alone, 10 self-expanding nitinol Xpert stents were deployed via a 4 F sheath. Stent characteristics and handling were graded by the interventionalist. Fontaine classification, duplex flow measurements and ankle brachial index (ABI) at rest and stress were taken prior and one day after stent placement. Patients were followed 3, 6 and 12 months after the procedure obtaining the same parameters at each appointment. Results: Initial stent treatment was successful in all patients. Stent handling and positioning were rated very good and safe. All patients improved clinically by at least one ...
2007-07-15
The mask detection technology for occluded face analysis in the surveillance system.
The surveillance systems have been widely used in automatic teller machines (ATMs), banks, convenient stores, etc. For example, when a customer uses the ATM, the surveillance systems will record his/her face information. The information will help us understand and trace who withdrew money. However, when criminals use the ATM to withdraw illegal money, they usually block their faces with something (in Taiwan, criminals usually use safety helmets or masks to block their faces). That will degrade the purpose of the surveillance system. In previous work, we already proposed a technology for safety helmet detection. In this paper, we propose a mask detection technology based upon automatic face recognition methods. We use the Gabor filters to generate facial features and utilize geometric analysis algorithms for mask detection. The technology can give an early warning to save-guards when any "customer" or "intruder" blocks his/her face information with a mask. Besides, the technology can ...
2005-05-01
Energy Technology Data Exchange (ETDEWEB)
GSTD1 is one of several insect glutathione S-transferases capable of metabolizing the insecticide DDT. Here we use crystallography and NMR to elucidate the binding of DDT and glutathione to GSTD1. The crystal structure of Drosophila melanogaster GSTD1 has been determined to 1.1 {angstrom} resolution, which reveals that the enzyme adopts the canonical GST fold but with a partially occluded active site caused by the packing of a C-terminal helix against one wall of the binding site for substrates. This helix would need to unwind or be displaced to enable catalysis. When the C-terminal helix is removed from the model of the crystal structure, DDT can be computationally docked into the active site in an orientation favoring catalysis. Two-dimensional {sup 1}H,{sup 15}N heteronuclear single-quantum coherence NMR experiments of GSTD1 indicate that conformational changes occur upon glutathione and DDT binding and the residues that broaden upon DDT binding support the ...
2010-06-14
Energy Technology Data Exchange (ETDEWEB)
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a ...
2009-04-15
The effect of type I migration on the formation of terrestrial planets in hot-Jupiter systems
Context: Our previous models of a giant planet migrating through an inner protoplanet/planetesimal disk find that the giant shepherds a portion of the material it encounters into interior orbits, whilst scattering the rest into external orbits. Scattering tends to dominate, leaving behind abundant material that can accrete into terrestrial planets. Aims: We add to the possible realism of our model by simulating type I migration forces which cause an inward drift, and strong eccentricity and inclination damping of protoplanetary bodies. This extra dissipation might be expected to enhance shepherding at the expense of scattering, possibly modifying our previous conclusions. Methods: We employ an N-body code that is linked to a viscous gas disk algorithm capable of simulating: gas accretion onto the central star; gap formation in the vicinity of the giant planet; type II migration of the giant planet; type I migration of protoplanets; and the effect of gas drag on ...
2007-01-01
On the origin of the Trojan asteroids Effects of Jupiter's mass accretion and radial migration
We present analytic and numerical results which illustrate the effects of Jupiter's accretion of nebular gas and the planet's radial migration on its Trojan companions. Initially, we approximate the system by the planar circular restricted three-body problem and assume small Trojan libration amplitudes. Employing an adiabatic invariant calculation, we show that Jupiter's thirty-fold growth from a $10 M_\\oplus$ core to its present mass causes the libration amplitudes of Trojan asteroids to shrink by a factor of about 2.5 to $\\sim 40%$ of their original size. The calculation also shows that Jupiter's radial migration has comparatively little effect on the Trojans; inward migration from 6.2 to 5.2 AU causes an increase in Trojan libration amplitudes of $\\sim4%$. In each case, the area enclosed by small tadpole orbits, if made dimensionless by using Jupiter's semimajor axis, is approximately conserved. Similar adiabatic invariant calculations for inclined and ...
2000-01-01
Investigation of Heat Transfer in Supercritical Fluids for Application to the Generation IV
Energy Technology Data Exchange (ETDEWEB)
Using a facility named SPHINX, which can accommodate a heat transfer test with CO{sub 2} at supercritical pressure, a series of tests was performed. The test geometries include tubes with the inner diameter of 4.4, 6.32 and 9 mm. a concentric annular passages with 8 x 10 mm, and an eccentric annular passages with 9.5 x 12.5 mm. Based on the test results, heat transfer correlations were developed and compared with the existing correlations. The heat transfer deterioration which may occur at certain conditions of heat and mass flux, were carefully studied and the published criteria were reviewed against our test results. Numerical calculation by using commercial CFD code, Fluent, were performed in order to provide the pre-test information for the heat transfer tests. Various turbulence models were evaluated and reliable models were suggested for each case
2007-08-15
Binaries migrating in a gaseous disk: Where are the Galactic center binaries?
The massive stars in the Galactic center inner arcsecond share analogous properties with the so-called Hot Jupiters. Most of these young stars have highly eccentric orbits, and were probably not formed in-situ. It has been proposed that these stars acquired their current orbits from the tidal disruption of compact massive binaries scattered toward the proximity of the central supermassive black hole. Assuming a binary star formed in a thin gaseous disk beyond 0.1 pc from the central object, we investigate the relevance of disk-satellite interactions to harden the binding energy of the binary, and to drive its inward migration. A massive, equal-mass binary star is found to become more tightly wound as it migrates inwards toward the central black hole. The migration timescale is very similar to that of a single-star satellite of the same mass. The binary's hardening is caused by the formation of spiral tails lagging the stars inside the binary's Hill radius. We show ...
2010-01-01
A ~5 M_earth Super-Earth Orbiting GJ 436?: The Power of Near-Grazing Transits
Most of the presently identified exoplanets have masses similar to that of Jupiter and therefore are assumed to be gaseous objects. With the ever-increasing interest in discovering lower-mass planets, several of the so-called super-Earths (i.e., with masses in the interval 1 M_earth < M < 10 M_earth), which are predicted to be rocky, have already been found. Here we report the possible discovery of a planet around the M-type star GJ 436 with a minimum mass of 4.8+/-0.6 M_earth and a true mass of ~5 M_earth, which makes it the least massive planet around a main-sequence star found to date. In contrast with other discoveries, the planet is identified from its perturbations on an inner Neptune-mass transiting planet (GJ 436b), by pumping eccentricity and producing secular variations in the orbital inclination. Analysis of published radial velocity measurements indeed reveals a significant signal corresponding to an orbital period that is very close to the 2:1 ...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Background and Purpose: During laser lithotripsy, working instruments are often in close proximity to the distal fiber tip and may be damaged accidentally or even intentionally. The aim of this study was to compare the amount of damage to a standard guidewire and the nitinol wires of endourologic retrieval baskets that were affected by three different clinically available laser systems. Materials and Methods: The impact of pulsed laser irradiation on a standard hydrophilic guidewire and a retrieval basket were investigated. One infrared (IR) laser system (holmium:yttrium-aluminum-garnet [Ho:YAG]: ????=???2100???nm) and two laser systems emitting light in the visible (VIS) spectral range (frequency-doubled double-pulse neodymium:YAG [FREDDY]: ????=???532???nm/1064???nm and flashl...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as ...
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at ...
2011-04-15
Energy Technology Data Exchange (ETDEWEB)
The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent vascular lumen within ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
Inferior vena cava (IVC) obstruction is a well-described clinical entity. Most IVC obstructions from malignant neoplasms are a direct result of tumor compression [Oviedo J, Cerda S. Vascular invasion by hepatocellular carcinoma. Arch Pathol Lab Med 2001;125: 454-5; Furui S, Sawada S, et al. Gianturco stent placement in malignant caval obstruction: analysis of factors for predicting the outcome. Radiology 1995;195:147-52; Fletcher WS, Lakin PC, et al. Results of treatment of inferior vena cava syndrome with expandable metallic stents. Arch Surg 1998;133:935-8]. The symptoms of IVC obstruction include progressive ascites, scrotal edema and lower body edema. These constellations of symptoms are described as IVC syndrome and are devastating to a patient with end-stage cancer. We describe a palliative therapy utilizing Luminexx nitinol self-expanding stents to treat intracaval hepatoma thrombus obstructing the IVC. The procedure is rapidly performed, technically ...
2008-05-15
Energy Technology Data Exchange (ETDEWEB)
We report the results of a prospective clinical study using a new self-expanding nitinol stent (Enterprise) designed for the treatment of wide-necked intracranial aneurysms. We treated 31 saccular, wide-necked intracranial aneurysms in 30 patients. Ten aneurysms had recanalized after prior endovascular treatment without a stent, and 21 aneurysms had not been treated before. Stent deployment was successful in all procedures. Additional coil embolization was performed in all aneurysms. Initial complete angiographic occlusion was achieved in 6 aneurysms, a neck remnant was left in 18 aneurysms and there were 7 residual aneurysms. Angiographic follow-up examinations of 30 lesions after 6 months demonstrated 15 complete occlusions, 8 neck remnants and 7 residual aneurysms. One patient refused the 6-month angiographic follow-up. Spontaneous occlusion of the aneurysm had occurred in 14 patients, and 6 aneurysms showed recanalization. Four of these residual aneurysms were ...
2007-07-15
Energy Technology Data Exchange (ETDEWEB)
Poly-Lactic-Acid (PLA) was evaluated for coating of vascular endoprotheses in the treatment of experimental arterio-venous-fistulae (AVF). Bilateral carotid-external jugular AVF were created in 5 adult dogs. 7 PLA coated nitinol stents were placed via a transfemoral approach covering 5 AVF. The contralateral AVF remained untreated. Angiography was performed immediately after stent placement, at weeks 1 and 3 and at months 3, 6 and 9. All grafts were removed and underwent histologic examination. In 2 cases the occlusion of the AVF was successful, while misplacement occurred in 3 cases. Occlusion of the parent vessel was disclosed in 3 cases. Histologic examination revealed a mild inflammatory reaction with the presence of macrophages. There was no foreign-body reaction or fragmentation of the arterial vessel wall. PLA, which is a well-known biodegradable material, showed a good mid-term biocompatibility. Elastic mismatch of the non-elastic coating and the ...
2001-02-01
International Nuclear Information System (INIS)
Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded Surface Display), ...
Glue embolization of aneurysm after stenting in canine carotid arteries-technical feasibility
International Nuclear Information System (INIS)
Coiling or infusion of embolic materials into a wide necked aneurysm can be performed with stenting. The purpose of our study is to assess the technical feasibility of aneurysm treatment with glue embolization after stenting. We used four Wallstents for surgically repairing eight canine carotid aneurysms. After confirmation of the aneurysms on the angiogram, we introduced a 6-7 F guiding catheter in order to deploy the stents. After stenting, we passed a microcatheter into the aneurysm lumen through the stent mesh. 28% glue was slowly injected until the glue cast completely filled the lumen. We evaluated the passage of a microcatheter through the stent meshwork, formation of the glue cast and the stents' ability to protection for any leakage of glue. The follow-up angiogram was obtained for two dogs, one to three times until 8 weeks, and then we sacrificed the dogs and performed pathologic examinations. Stenting was successful in all cases except one in which the vessel was ...
2004-10-01
Energy Technology Data Exchange (ETDEWEB)
Cretaceous Sunniland Formation rudistid reservoir facies buried at 3,520 meters (92 C) between evaporite units contain marginally mature algal sapropelic carbonate source rock hydrocarbons. The closed system aids in identification of porosity redistribution related to hydrocarbon emplacement. Multiple dissolution and cementation events associated with hydrocarbon migration pulses are particularly evident along stylolites. Corrosion usually predates typically interparticle first generation saddle dolomite, and corroded saddle dolomite may be observed with two generations of optically continuous limpid overgrowths separated by a corrosive boundary. Dissolution or dedolomitization may provide a magnesium source for subsequent dolomite cements. Carbonic and organic acids are probable primary corrosive agents. Moldic, stylolite and fracture porosity, often reduced by dolomite cements, was generated. Moldic pores may develop from peloids by dissolution of peripheral micritized areas. If ...
1994-03-01
A comparison of algorithms for inference and learning in probabilistic graphical models.
Research into methods for reasoning under uncertainty is currently one of the most exciting areas of artificial intelligence, largely because it has recently become possible to record, store, and process large amounts of data. While impressive achievements have been made in pattern classification problems such as handwritten character recognition, face detection, speaker identification, and prediction of gene function, it is even more exciting that researchers are on the verge of introducing systems that can perform large-scale combinatorial analyses of data, decomposing the data into interacting components. For example, computational methods for automatic scene analysis are now emerging in the computer vision community. These methods decompose an input image into its constituent objects, lighting conditions, motion patterns, etc. Two of the main challenges are finding effective representations and models in specific applications and finding efficient algorithms for inference and ...
2005-09-01
Vibration characteristics of SMA composite beams with different boundary conditions
Energy Technology Data Exchange (ETDEWEB)
Recently, the development of shape memory alloy (SMA) actuators, in the forms of wire, thin film and stent have been found increasingly in the fields of materials science and smart structures and engineering. The increase in attraction for using these materials is due to their many unique materials, mechanical, thermal and thermal-mechanical properties, which in turn, evolve their subsequent shape memory, pseudo-elasticity and super-elasticity properties. In this paper, a common type of SMA actuator, Nitinol wires, were embedded into advanced composite structures to modulate the structural dynamic responses, in terms of natural frequency and damping ratio by using its shape memory and pseudo-elastic properties. A simple theoretical model is introduced to estimate the natural frequency of the structures before and after actuating the embedded SMA wires. The damping ratios of different SMA composite beams were measured through experimental approaches. The natural ...
2002-12-15
Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to ...
2008-11-15
Some medical applications of thermomechanically treated titanium nickelide
Energy Technology Data Exchange (ETDEWEB)
An original device and a method of its application for restoring of the function of relatively incompetent valves (both patented) are elaborated. Application of the new device allows to lower the difficulty of surgical treatment, to decrease the duration of operation and post-operative period. The long-term results of six-year long experience of its application are presented. The patients examination after 2,5-3,0-year post-operation period shows perfect vein valve correction. A device for stone extraction from tubular organs (patented) fabricated with titanium nickelide superelastic alloy is presented. The new suggested design is free of the drawback inherent in the previous one. The working element of the device is formed as a truncated cone or a truncated cone coaxial with the cylinder (the previous design was formed as a full cone) that prevents overstraining and residual strain accumulation during the manipulation process. Since the first publication the design of spiral stent and ...
2001-11-01
Retrieval of intravascular foreign bodies with goose neck snare
Energy Technology Data Exchange (ETDEWEB)
Purpose: to evaluate the efficacy and advantages of the snare systems in the retrieval of foreign bodies from vascular system. Materials and methods: the snare technique has been used for intravascular foreign body retrieval. We performed percutaneous extraction of intravascular foreign bodies using combination multipurpose catheters and a nitinol snare loop. In this report, we evaluated the patients who had performed endovascular device reposition or foreign body retrieval from 1998 to 2001. Results: foreign body retrieval was performed in 15 patients. The foreign bodies consisted of seven fractured port catheters, one sheath fragment, one embolization coil, four wire fragments, one pace-maker transducer and one dislocated endovascular stent. In no case were surgical procedures required, and no complications were encountered. Conclusion: the snare technique is a useful and a safe method as an alternative procedure to surgery. This technique is highly effective ...
2004-03-01
Energy Technology Data Exchange (ETDEWEB)
Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren ...
2010-01-15
Aortic non communicating dissections. A study with helical CT
International Nuclear Information System (INIS)
The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at baseline CT and had low ...
2000-09-01
A new concept for covered stent protected carotid angioplasty: an ex vivo study
Energy Technology Data Exchange (ETDEWEB)
Objective: To determine the efficacy of a covered stent prototype designed for protected carotid angioplasty to reduce cerebral embolization. Material and Method: The covered stent tested is made of nitinol, coated with a polyurethane membrane (MembraX{sup TM}; porous size 80 {mu}m). In a bench-top model (flow-rate 650 ml/min, pulsatile flow [dicrote] 123 Pulses/min, pressure 100/60 mm Hg [mean pressure 80 mmHg]) with inserted human carotid (n=6) stent implantation was performed (8/32 mm). Passed particles (mg) were determined in the effluent of a 100 {mu}m filter prior to intervention, after stent deployment and after final dilation (5 mm). Results: When stenting carotid arteries obtained from human cadavers, the highest rate of particle embolization was measured while crossing the lesion with the delivery device (6,8 mg; for all p<0,05), embolization after additional balloon angioplasty and particle rates measured in the effluent filter prior covered stent ...
2003-12-01
Transluminal radio-frequency thermal ablation using a stent-type electrode: an experimental study
Energy Technology Data Exchange (ETDEWEB)
To assess the feasibility of transluminal radiofrequency thermal ablation using a stent-type electrode and to determine, by means of in-vivo and in-vivo animal studies, the appropriate parameters. In-vivo: the radiofrequency electrode used was a self-expandable nitinol stent with 1cm insulated ends. A stent was placed in the portal vein of bovine liver, and ablations at target temperatures of 70, 80, 90, and 100 .deg. C were performed. Ablated sizes were measured longitudinally. In vivo: four mongrel dogs were anesthetized, and a stent was inserted in the common bile duct under fluoroscopic guidance through an ultrasound-guided gall bladder puncture site. The ablation temperature was set at 80 .deg. C, and each dog underwent proximal and distal esophageal ablations lasting 12 minutes. They were sacrificed immediately. In-vivo: ablated sizes showed significant correlation with target temperatures (r>0.04; p<0.05). Although most lesions were fusiform, ...
2003-06-01
Stent insertion in patients with malignant biliary obstruction: problems of the Hanaro stent
Energy Technology Data Exchange (ETDEWEB)
To investigate the problems of the Hanaro stent (Solco Intermed, Seoul, Korea) when used in the palliative treatment of patients with inoperable malignant biliary obstruction. Between January 2000 and May 2001, the treatment of 46 patients with malignant biliary obstruction involved percutaneous placement of the Hanaro stent. Five patients encountered problems during removal of the stent's introduction system. The causes of obstruction were pancreatic carcinoma (n=2), cholangiocarcinoma (n=2), and gastric carcinoma with biliary invasion (n=1). In one patient, percutaneous transhepatic cholangiography and stent insertion were performed as a one-step procedure, while the others underwent conventional percutaneous transhepatic biliary drainage for at least two days prior to stent insertion. A self-expandable Hanaro stent, 8-10 mm in deameter and 50-100 mm in lengh, and made from a strand of nitinol wire, was used in all cases. Among the five patients who ...
2002-07-01
Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model
Energy Technology Data Exchange (ETDEWEB)
Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the ...
2007-02-15
Energy Technology Data Exchange (ETDEWEB)
To assess the technical feasibility of a newly designed stent-like electrode in rabbits. A stent-like electrode was knitted from a single thread of nitinol wire and interconnected to a generator using similar wire. In order to gauge the extent of radiofrequency ablation (RFA), we measured the depth of the ablated area in cow liver using a combination of 180-sec time intervals and 20- watt power increments. For data processing, Cox regression analysis was used. RFA was also applied to the small intestine of rabbits using this stent-like electrode under six different sets of conditions: 10 watts for 1 min, 10 watts for 2 mins, 20 watts for 1 min, 20 watts for 2 mins, 30 watts for 1 min, and 30 watts for 2 mins. To determine the gross and microscopic findings, six animals were sacrificed immediately after the procedure and the results obtained under the different sets of conditions were correlated. Eight rabbits were monitored for 4 weeks prior to sacrifice. For both ...
2003-03-01
Energy Technology Data Exchange (ETDEWEB)
We wanted to evaluate the procedural success after percutaneous treatment of thrombosed native arteriovenous dialysis fistula insufficiency and the efficacy of performing mechanical thrombectomy with using the stone basket. From March 2004 to June 2005, 36 thrombosed native hemodialysis access shunts in the upper limbs (brachiocephalic fistulas: 16 and radiocephalic fistulas: 20) were percutaneously treated in 30 patients. Declotting procedures were performed with using urokinase (100,00-200,000 unit) and manual catheter-directed thrombo-aspiration in all the patients. Angioplasty (6 mm in diameter and 4 cm in length) was performed at the identified area of the stenosis and /or with maceration of the thrombus. In 14 cases with massive thrombosis that was refractory to the above mentioned declotting procedures, mechanical thrombectomy with using a Wittich nitinol stone basket (Cook, Bloomington, IN) was performed. Data regarding the procedural success rate and the ...
2006-06-15
Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation
Energy Technology Data Exchange (ETDEWEB)
The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation values were observed in all cases. The stent ...
2003-04-01
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to investigate the feasibility and the optimal conditions of radiofrequency (RF) ablation by using the stent-type electrode upon the saphenous vein of goats for the endovenous treatment of varicose veins. A self-expandable nitinol stent electrode (6 mm diameter, 2 cm length, cell size; 1.3 x 2 mm) was designed to expose the distal 1 cm segment to allow for contact with the venous wall. The proximal part of the electrode was connected to the RF generator by insulated copper wires located within the stent electrode introducer. Initially, to optimize the power setting, ablation of 6 saphenous veins in 3 goats was performed with power settings of 10, 20 and 30 W. Pull back rate of the electrode was 2 and 4 cm/min for each power level, respectively. The goats were sacrificed 4-6 weeks later and histologic examinations of the saphenous veins were done. For the second part of the experiment, RF ablation of 4 saphenous veins from 2 goats was ...
2004-10-15
The efficacy of metallic stent placement in the treatment of colorectal obstruction
Energy Technology Data Exchange (ETDEWEB)
To evaluate the efficacy of newly designed covered and non-covered coated colorectal stents for colonic decompression. Twenty-six patients, (15 palliative cases and 11 preoperative) underwent treatment for the relief of colorectal obstruction using metallic stents positioned under fluoroscopic guidance. In 24 of the 26, primary colorectal carcinoma was diagnosed, and in the remaining two, recurrent colorectal carcinoma. Twenty-one patients were randomly selected to receive either a type A or type B stent; for the remaining five, type C was used. Type A, an uncovered nitinol wire stent, was lightly coated to ensure structural integrity. Type B (flare type) and C (shoulder type) stents were polyurethane covered and their diameter was 24 and 26mm, respectively. The rates of technical success, clinical success, and complications were analyzed using the chi-square test, and to analyse the mean period of patency, the Kaplan-Meier method was used. Thirty of 31 attempted ...
2002-06-01
Energy Technology Data Exchange (ETDEWEB)
Nickel-titanium alloys may coexist in more than one crystalline structure. There is a high temperature phase, austenite, and a low temperature phase, martensite. The metallurgical basis for the superelasticity and the shape memory effect relies in the ability of these alloys to transform easily from one phase to another. There are three essential factors for the orthodontist to understand nickel-titanium alloys behaviour: stress; deflection; and temperature. These three factors are related to each other by the stress-deflection, stress-temperature and deflection-temperature diagrams. This work was undertaken with the objective to analyse commercial nickel-titanium alloys for orthodontics application, using the dynamical mechanical analyser - DMA. Four NiTi 0,017 X 0,025'' archwires were studied. The archwires were Copper NiTi 35 deg C (Ormco), Neo Sentalloy F200 (GAC), Nitinol Superelastic (Unitek) and NiTi (GAC). The different mechanodynamical ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluated artifacts of unexpended stents and to determine their exact position for MR-guided percutaneous transluminal angioplasty using real-time sequences. Materials and Methods: By using an in vitro model, 11 unexpended stents - 9 nitinol, 1 stainless steel, and 1 cobalt alloy - were investigated by MR. Each stent was studied in a vessel-phantom filled with saline solution. Imaging was performed using five different realtime sequences: fast low angle shot (Flash 2D), fast imaging with steady precession (true FISP, FISP, interactive true FISP) and segmented echo planar imaging (seg. EPI). Artifacts of the introducer system and the stent were calculated by four blinded radiologists (scale: 1 - artifacts, making an excellent contribution to visualization; 2 - artifacts, making mainly a contribution to visualization; 3 - artifacts, making no contribution to visualization). Furthermore, an evaluation of the visibility of the tip of the stent-catheter and ...
2004-09-01
64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate ...
2006-04-15
Energy Technology Data Exchange (ETDEWEB)
Objective: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. Methods: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2-4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. Results: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8-10 mm diameter/40-80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p<0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16%) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79% (n=15) of patients ...
2002-10-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
