WorldWideScience
1

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

2

EBIT - Electronic Beam Ion Trap: N Divison experimental physics annual report 1995  

Energy Technology Data Exchange (ETDEWEB)

The multi-faceted research effort of the EBIT (Electron Beam Ion Trap) program in N-Division of the Physics and Space Technology Department at Lawrence Livermore National Laboratory (LLNL) continues to contribute significant results to the physical sciences from studies with low energy very highly charged heavy ions. The EBIT program attracts a number of collaborators from the US and abroad for the different projects. The collaborations are partly carried out through participating graduate students demonstrating the excellent educational capabilities at the LLNL EBIT facilities. Moreover, participants from Historically Black Colleges and Universities are engaged in the EBIT project. This report describes EBIT work for 1995 in atomic structure measurements and radiative transition probabilities, spectral diagnostics for laboratory and astrophysical plasmas, ion/surface interaction ...

1996-10-01

3

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric ...

2004-12-15

4

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

5

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...

2009-01-01

6

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In ...

2007-01-01

7

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

8

Emission Line Spectra in the Soft X-Ray Region 20-75 (Angstrom)  

Energy Technology Data Exchange (ETDEWEB)

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EBIT-II, we studied emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region. Here we present observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 {angstrom} to illustrate our work.

2002-06-18

10

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

11

Hadron Calorimeter Endcap  

International Science & Technology Center (ISTC)

Development of the Technology and Control of Electron-Beam Welding Procedure and Production of Full Scale Sector of Endcap CMS Hadron Calorimeter. Preparation for Mass Production.

12

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

13

Oxygen carriers for chemical looping combustion of solid fuels  

Energy Technology Data Exchange (ETDEWEB)

A thermal analyzer-differential scanning calorimeter-mass spectrometer (TG-DSC-MS) was used to study oxygen carriers (OC) for their potential use for the application of chemical looping combustion (CLC) to solid fuels. Reaction rates, changes in reaction rates with repeated oxidation-reductions, exothermic heats during oxidation, and the effect of changing reduction gas compositions were studied. Oxidation rates were greater than reduction rates and reaction rates were reproducible through multiple oxidation-reduction cycles except where agglomeration occurred with powders. Iron oxide (Fe{sub 2}O{sub 3} powder) and iron-based catalysts were found suitable for CLC of solid fuels having rapid reduction rates which increased with higher reducing gas concentrations. Fe{sub 2}O{sub 3} powder was used to oxidize a high carbon coal char in an inert gas removing 88% of the carbon from the char. Other properties such as cost and durability indicated ...

2009-05-15

14

A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation  

CERN Document Server

A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter ...

2008-01-01

16

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

18

The AMS-02 electromagnetic calorimeter  

CERN Document Server

The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).

2002-01-01

19

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer  

CERN Document Server

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer

1998-01-01

20

Modifications to the rotating crystal spectrometer  

International Nuclear Information System (INIS)

... bf3 counters data multi-channel analyzers multivibrators neutron spectrometers

21

Analysis of the Semileptonic Decay D0 --> anti-K0 pi- mu+ nu  

Energy Technology Data Exchange (ETDEWEB)

This thesis describes the analysis of the semileptonic decay D{sup 0} {yields} {bar K}{sup 0} {pi}{sup -} {mu}{sup +}{nu} using FOCUS data. FOCUS is a fixed target experiment at Fermilab that studies the physics of the charm quark. Particles containing charm are produced by photon-gluon fusion from the collision of a photon beam on a BeO target. The experiment is characterized by excellent vertex resolution and particle identification. The spectrometer consists of three systems for track reconstruction (two silicon systems and one multiwire proportional chamber system) and two magnets of opposite polarity. The polarity of the magnet is such that the events of e{sup +}e{sup -} pairs produced in the target (which constitutes the main background) travel through a central opening in the detectors without interactions. Particle momentum is measured from the deflection angle in the magnets. Three multicell Cerenkov counters are used for charged particle identification ...

2004-11-01

23

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward ...

2004-01-01

24

Investigation of the local hardening effect produced by various low-Z materials in a Si/(Fe, Pb) electromagnetic calorimeter  

International Nuclear Information System (INIS)

The condition for obtaining a calorimetric response linear with energy for hadronic showers and an energy resolution that improves as the incident energy increases is the equalization of the electromagnetic (e) and the hadronic (#pi#) signal responses. This equalization is obtained by exploiting a local hardening effect realized through the insertion of low-Z thin plates between the high-Z absorbers and the active material in a hadronic calorimeter with silicon readout. This effect, which allows the reduction of the calorimeter response to the electromagnetic component of the incoming hadronic showers, has been investigated for different low-Z materials. The relevance of some aspects of this study to the radiation hardness of the calorimeters is also addressed. (orig.).

25

High Energy Physics Program at the University of Alabama  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: study of Z{sup 0} decays; QCD; new particles; Higgs bosons; and forward hadron calorimeter system.

1990-09-01

26

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

27

Study of cosmic ray nuclei detection by an image calorimeter  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.

1995-09-01

28

The sup(187m)Ir isomer state and its decay scheme  

International Nuclear Information System (INIS)

... beta spectrometers comparative evaluations data decay electrons

29

The conversion spectrum of Sr"8"8  

International Nuclear Information System (INIS)

... beta spectrometers decay energy-level transitions k conversion l conversion

34

Relative luminosity measurement of the LHC with the ATLAS forward calorimeter  

CERN Document Server

In this paper it is shown that a measurement of the relative luminosity changes at the LHC may be obtained by analysing the currents drawn from the high voltage power supplies of the electromagnetic section of the forward calorimeter of the ATLAS detector. The method was verified with a reproduction of a small section of the ATLAS forward calorimeter using proton beams of known beam energies and variable intensities at the U-70 accelerator at IHEP in Protvino, Russia. The experimental setup and the data taking during a test beam run in April 2008 are described in detail. A comparison of the measured high voltage currents with reference measurements from beam intensity monitors shows a linear dependence on the beam intensity. The non-linearities are measured to be less than 0.5 % combining statistical and systematic uncertainties.

2010-01-01

35

Cosmic ray antiproton/electron discrimination capability of the CAPRICE silicon-tungsten calorimeter using neural networks  

Energy Technology Data Exchange (ETDEWEB)

A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imaging calorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).

1996-11-01

36

A water calorimeter for high energy x-rays and electrons  

CERN Document Server

The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of ...

2000-01-01

37

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01

38

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

39

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

40

USSR Report, Electronics and Electrical Engineering.  

Science.gov (United States)

... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...

1985-04-30

41

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

42

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

43

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

44

FOCUS: time-of-flight spectrometer for cold neutrons at SINQ  

Energy Technology Data Exchange (ETDEWEB)

The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.

1996-11-01

45

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

46

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

Energy Technology Data Exchange (ETDEWEB)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also ...

2009-06-15

47

Evaluation of tritium diffusion through the Neutral Beam Injector calorimeter panel  

International Nuclear Information System (INIS)

The Neutral Beam Test Facility (NBTF) to be realized in Padoa will test the Neutral Beam Injection (NBI), one of the Heating and Current Drive Systems foreseen for ITER. The NBI is based on the acceleration of hydrogen or deuterium negative ions up to 1 MeV. This work has been aimed at assessing the tritium release from the NBTF in order to provide data for the safety analysis. In particular, the diffusion of the tritium through the neutral beam target material (the CuCrZr alloy calorimeter panels) has been assessed by using literature data of the diffusion coefficient. The tritium generated inside the calorimeter panels moves into both the vacuum and water side: the tritium diffusion flux has been evaluated during the beam-on (200 deg. C) and the beam-off (20 deg. C) phases of the NBTF experiments consisting of an interim campaign and a final test. The penetration depth of the tritium through the 2 mm thick CuCrZr alloy material has been also ...

2009-06-01

48

Sampling and chemical analysis of smoke gas components from the SP Industry Calorimeter  

Energy Technology Data Exchange (ETDEWEB)

This report describes the sampling and chemical analyses of smoke gas components for combustion performed in the SP Industry Calorimeter, where continuous measurements of oxygen, carbon dioxide and carbon monoxide are an integrated part of the Calorimeter system. On-line measurements of nitrogen oxides and total amounts of unburnt hydrocarbons were performed. Hydrogen cyanide, hydrogen chloride and ammonia in the smoke were sampled and absorbed in impinger bottles and subsequently analyzed using wet chemical techniques. An adsorbent sampling system was designed to allow the identification and quantitative analysis of individual organic compounds in the smoke. Gas chromatography was utilized with a mass spectrometric detector for the identification and a FID for quantification of the total amounts as well as individual components. A procedure for cleaning the smoke gas duct in between the combustion experiments was designed and found to be ...

1995-12-31

49

Construction of the ATLAS end cap electromagnetic calorimeter and study of its performances; Construction du bouchon du calorimetre electromagnetique d'ATLAS et etudes de ses performances  

Energy Technology Data Exchange (ETDEWEB)

ATLAS is one of the four experiments which will take place at the LHC, the CERN future protons collider. This accelerator, which should start in 2007, will allow to continue the studies carried out by its predecessors, as the standard model Higgs boson and new physics searches. The very high luminosity -10 fb{sup -1} during the first three functioning years, then 100 fb{sup -1}- and the 14 TeV in the frame center will ease these studies. The Centre de Physique des Particules de Marseille took part in the ATLAS collaboration, taking in charge half of the End-cap electromagnetic calorimeter modules construction. The description of this sub-detector and the construction steps, in particular the electrical tests which allow the stacking validation, are presented in this document. These tests results, obtained for the live first production modules, are analysed. The pre-series module (module 0) performances, obtained with beam tests performed at CERN in 1999, are also ...

2002-09-01

50

PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies  

Energy Technology Data Exchange (ETDEWEB)

We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).

1990-09-15

51

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

52

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

53

Remote Sensor Systems for Unmanned Planetary Missions  

Science.gov (United States)

instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...

54

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

55

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

56

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

57

Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy  

Energy Technology Data Exchange (ETDEWEB)

We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.

1995-04-13

58

New crystals for dual-readout calorimetry  

CERN Document Server

Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.

2009-01-01

59

Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).

1997-06-21

60

ATLAS tile calorimeter electronics upgrade  

CERN Document Server

This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.

2011-01-01

61

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

62

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

63

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

64

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

65

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

66

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

67

MEMS-based Speckle Spectrometer  

CERN Document Server

We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing ...

2006-01-01

68

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best ...

2006-12-21

69

Practical operation of a trumpet secondary concentrator with a cavity receiver at elevated temperatures  

Energy Technology Data Exchange (ETDEWEB)

A prototype trumpet type nonimaging secondary concentrator was designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW{sub e} dish-Stirling system. A set of operational tests was carried out with a high temperature heat pipe receiver and gas-gap calorimeter. These tests have successfully alleviated any operational concerns about the effectiveness of active water cooling for such devices. The authors obtained over two full days of testing with the cavity receiver operating at its design temperature of 660 C while the trumpet throat temperature remained {approx_equal} or less than 100 C. In addition, these tests have shown that the thermal isolation of the trumpet from the hot receiver is very effective. Highly variable insolation, instabilities in the temperature controller on the calorimeter, and a poor match between the optical quality of the primary and the design of the trumpet have made detailed quantitative results ...

1997-12-31

70

Enthalpy changes upon partial evaporation of aqueous solutions containing ammonia and carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

The thermodynamic properties of aqueous solutions containing ammonia and sour gases such as carbon dioxide, sulfur dioxide, or hydrogen sulfide must be known in many applications. A typical example is the cleaning of raw gases in power stations. The enthalpy changes upon partial evaporation of aqueous solutions containing ammonia and of aqueous solutions containing ammonia and carbon dioxide were measured at temperatures from 313 to 393 K with a thin film evaporator flow calorimeter. The molalities of ammonia and carbon dioxide entering the calorimeter ranged up to 12 and 6 mol/kg, respectively. The physicochemical model originally developed by Edwards et al. (1978) and further modified and extended by Kurz et al. (1995) to describe phase equilibria in aqueous systems containing ammonia and carbon dioxide is used to derive a predictive enthalpy model for this complex, chemical reactive system. Comparisons between the new experimental results ...

1998-08-01

71

Comparison of doubly labeled water, intake-balance, and direct- and indirect-calorimetry methods for measuring energy expenditure in adult men  

International Nuclear Information System (INIS)

Energy expenditure (EE) of four adult men on a weight-maintenance diet was estimated by use of doubly labeled water, intake balance, and direct and indirect calorimetry. The doubly labeled water (2H218O) method was used to estimate free-living EE for 13 d. Metabolizable energy (ME) intake was used to estimate free-living EE for 1 wk. The subjects' 24-h EE was measured in a dual direct-indirect room calorimeter on 3 alternate days. Estimates of free-living EE as measured by ME intake and doubly labeled water indicate agreement between the two methods (mean difference +/- SEM, -1.04 +/- 0.63%). Measurements of EE with indirect and direct calorimetry are equivalent (mean difference 0.63 +/- 0.44%). The daily EE measured by doubly labeled water in these free-living adults over a 13-d period was 15.01% greater than the 24-h EE measured within the calorimeter.

72

Thermodynamics of potassium diclofenac salt aqueous solutions at various temperatures  

British Library Electronic Table of Contents (United Kingdom)

Solution and dilution enthalpies of aqueous solutions of potassium diclofenac salt (K_DC) were measured by an isoperibolic calorimeter at 298.15 and 318.5?K. Heat capacities of the solutions with concentrations 0.002?0.09?mol?kg?1 were obtained at the temperature interval of 288.15?318.15?K using a scanning adiabatic microcalorimeter. The virial coefficients were derived from Pitzer?s model, and the excess thermodynamic functions of both the solvent and the solute of the solution were calculated. The concentration and temperature dependencies of thermodynamic characteristics of the solution were analyzed and discussed.

2011-01-01

73

Thermodynamic Model of Aluminum Combustion in SDF Explosions  

Energy Technology Data Exchange (ETDEWEB)

Thermodynamic states encountered during combustion of Aluminum powder in Shock-Dispersed-Fuel (SDF) explosions were analyzed with the Cheetah code. Results are displayed in the Le Chatelier diagram: the locus of states of specific internal energy versus temperature. Accuracy of the results was confirmed by comparing the fuel and products curves with the heats of detonation and combustion, and species composition as measured in bomb calorimeter experiments. Results were fit with analytic functions u = f(T) suitable for specifying the thermodynamic properties required for gas-dynamic models of combustion in explosions.

2006-06-19

74

Simultaneous measurement of the neutron capture and fission yields of "2"3"3U  

International Nuclear Information System (INIS)

We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)

2007-04-22

75

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

76

Results of a search for monopoles and tachyons in horizontal cosmic ray flux  

International Nuclear Information System (INIS)

A search for monopoles and tachyons at ground level was carried out using an arrangement consisting of an ionization calorimeter and two hodoscope detectors. No clear evidence for these particles was obtained. The flux of monopoles with velocities beta approximately 0.01 is found to be less than 5.1 x 10 to the minus 13th power square centimeters s(-1) sr(-1) (95% cl.). The upper limit on the tachyon flux density is set as a 6 x 10 the minus 9th power particle/square centimeter event.

1985-08-01

77

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

78

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

79

Performance of the transition radiation detector flown on the NMSU/WIZARD TS93 balloon-borne instrument  

Energy Technology Data Exchange (ETDEWEB)

It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.

1995-09-01

80

Heat capacity measurement of some breeder materials  

International Nuclear Information System (INIS)

Isobaric molar heat capacities of powder and microsphere form of Li2TiO3 (s) and powder form of LiAlO2 (s) and Li2ZrO3 (s) were measured using a heat flux type differential scanning calorimeter in the temperature range 320 - 870 K. Specific heat capacities of LiAlO2 (s) was found to be much larger compared to those of Li2TiO3 (s) and Li2ZrO3 (s). (author)

2009-01-07

81

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

82

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

83

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...

2010-11-11

84

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

85

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

86

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

87

Diode laser overtone spectroscopy of CO_2 at 780nm  

International Nuclear Information System (INIS)

Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbance detected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.

2005-12-01

88

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement ...

1985-07-03

89

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.

90

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-09-01

91

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

92

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

93

Revision I July 29, 2009 - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...

94

Project Technical ... - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...

95

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...

1991-06-18

96

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...

1989-04-04

97

AMS Project Plan - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...

98

A new analysis for membrane noise. The integral spectrum.  

UK PubMed Central (United Kingdom)

A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available

1976-07-01

99

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

100

Results from a Bragg Curve Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-01-01

101

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-10-22

102

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

103

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

104

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

105

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

106

In-place testing of HEPA filter systems by the single-particle, particle-size spectrometer method  

Energy Technology Data Exchange (ETDEWEB)

This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.

1981-12-01

107

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

108

Application of the digital waveform analysis to Bragg curve spectrometer  

International Nuclear Information System (INIS)

Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)

2004-11-01

109

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

110

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

111

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated ...

1999-11-01

112

The {sup 234}U neutron capture cross section measurement at the n TOF facility  

Energy Technology Data Exchange (ETDEWEB)

The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)

2008-07-01

113

The CDF II eXtremely Fast Tracker Upgrade  

International Nuclear Information System (INIS)

The CDF II eXtremely Fast Tracker (XFT) is the trigger processor which reconstructs charged particle tracks in the CDF II central outer tracking chamber. The XFT tracks are also extrapolated to the electromagnetic calorimeter and muon chambers and are associated to electromagnetic clusters and muon stubs to generate trigger electron and muon candidates. The steady increase of the Tevatron instantaneous luminosity and the resulting higher occupancy of the chamber demanded an upgrade of the original system, which performed tracking only in the transverse plane of the chamber and was consequently affected by a significant level of fake tracks. In the upgraded XFT, tracking is reinforced by using additional data from the stereo layers of the chamber to reduce the level of fake tracks and to perform three-dimensional track reconstruction. A review of this upgrade is presented.

2007-10-21

114

Search for Neutron-Antineutron Oscillations Using Multiprong Events in Soudan 2  

CERN Document Server

We have searched for neutron-antineutron oscillations using the 5.56 fiducial kiloton-year exposure of the Soudan 2 iron tracking calorimeter. We require candidate n-nbar occurrences to have .GE. 4 prongs (tracks and showers) and to have kinematics compatible with nbar-N annihilation within a nucleus. We observe five candidate events, with an estimated background from atmospheric neutrino and cosmic ray induced events of 4.5 \\pm 1.2 events. Previous experiments with smaller exposures observed no candidates, with estimated background rates similar to this experiment. We set a lifetime lower limit for oscillation time in iron: T_A(Fe) > 7.2x10^{31} years. The corresponding lower limit for oscillation of free neutrons is \\tau_{n-nbar} > 1.3x10^8 seconds.

2002-01-01

115

Particle Flow at CMS and the ILC  

CERN Document Server

This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy measurement of hadrons at CMS. The networks ...

2010-01-01

116

Investigating the effect of an arterial hypertension drug on the structural properties of plasma protein  

British Library Electronic Table of Contents (United Kingdom)

Propanolol is a betablocker drug used in the treatment of arterial hypertension related diseases. In order to achieve an optimal performance of this drug it is important to consider the possible interactions of propanolol with plasma proteins. In this work, we have used several experimental techniques to characterise the effect of addition of the betablocker propanolol on the properties of bovine plasma fibrinogen (FB). Differential scanning calorimeter (DSC), circular dichroism (CD), dynamic light scattering (DLS), surface tension techniques and atomic force microscopy (AFM) measurements have been combined to carry out a detailed physicochemical and surface characterization of the mixed system. As a result, DSC measurements show that propranolol can play two opposite roles, either acting ...

2011-01-01

117

Fractality in high energy cosmic rays  

Energy Technology Data Exchange (ETDEWEB)

Using EAS data from the EAS-EXC group (EAS plus hadronic calorimeter and nuclear emulsion-X chamber hybrid experiment) on Mount Chacaltaya during the 1990's the fractal properties of the energetic cosmic ray fluxes was investigated. A discrimination in the hadron content of the energetic primaries furnishes two different data samples, the total EAS fluxes and the hadron-less fluxes. The sidereal diurnal variation of the hadron-less EAS time variation shows values of 0.5% with a phase at about 2.29 hr sidereal time. With the help of the Crassberger Procaccia algorithm the fractal dimensions have been investigated of, on the one hand, the differences in arrival times of the hadron-less showers and on the other hand the EAS fluxes time series with an integration time of five min. The obtained fractal dimensions show inconclusive evidence of continuous chaotic component in the data samples investigated.

2003-07-01

118

Fluoride phosphate Li{sub 2}CoPO{sub 4}F as a high-voltage cathode in Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

As a new high-voltage cathode candidate for post 4V cathodes, ordered-olivine LiCoPO{sub 4} and fluoride phosphate, Li{sub 2}CoPO{sub 4}F were synthesized by solid-state reaction. Their structures were identified by neutron diffraction. The 5V discharge profiles were demonstrated using coin-type cells. Two important issues for commercial use, metal dissolution and oxygen release at elevated temperatures, were also tested with an atomic absorption spectrophotometer and differential scanning calorimeter, respectively. (author)

2005-08-26

119

Flame retardancy of polybutylene terephthalate blended with various oxides  

British Library Electronic Table of Contents (United Kingdom)

The flame retardancy of polybutylene terephthalate (PBT) was studied focusing on the effect of various oxides. Thermo-gravimetric analysis, pyrolysis/gas chromatography/mass spectrometry, and elemental analysis (EA) were used to analyze the flame retardancy, which were observed through the UL-test and a cone calorimeter. Many oxides influenced the flame retardancy and some of them could suppress the flammability of PBT. In particular, the blended-PBTs with ZnO and V2O5 accelerated the degradation and the edges of oxygen consumption were shorter than neat-PBT although the flammability became poorer. The quantitative analysis of the scission products and the results of EA showed that hydrolysis, successive dehydration, and other various reactions changed the scission route to generate less f...

2008-01-01

120

Enhancement of convective heat transfer by using microencapsulated PCM slurry  

Energy Technology Data Exchange (ETDEWEB)

As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.

1998-11-01

121

Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K  

International Nuclear Information System (INIS)

The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al_2O_3 x H_2O), which dehydrated to alumina (Al_2O_3) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.

1991-01-01

122

Effect of On-Chip Magnetic Shielding for TES Microcalorimeters  

British Library Electronic Table of Contents (United Kingdom)

We investigated the magnet field dependence of the X-ray pulse height and the critical current of a Ti/Au bilayer TES micro-calorimeter. The pulse height was strongly affected by the magnetic field intensity applied perpendicularly to the TES surface. We found that the critical current at zero temperature, I c0, decreased by a factor of two by applying a magnet field of ?10??T. Our data are consistent with a TES sensitivity proportional to (I/I c0)?2/3, as predicted by the Ginzburg-Landau theory. This fact implies that the shape of the R?T curve of the TES is partly determined by the critical current of the superconductor. In order to make our TES microcalorimeters less sensitive to the external magnetic field, we fabricated devices equipped with on-chip magnetic shielding. One device has ...

2008-01-01

123

Effect of Al and AlP on the microstructure of Mn-30 wt.%Si alloy  

Energy Technology Data Exchange (ETDEWEB)

Effect of Al and AlP particles on the microstructure of near eutectic Mn-Si alloy (Mn-30 wt.%Si) was studied by Electron Probe Micro-analyzer (EPMA) and Differential Scanning Calorimeter (DSC). Crystal lattice correspondence analyses show that both Al and AlP have good lattice matching coherence relationships with MnSi phase, and the addition of Al and AlP particles results in an abnormal eutectic structure, i.e. the eutectic constitution MnSi and Mn{sub 5}Si{sub 3} precipitate separately: MnSi precipitates firstly, and then the Mn{sub 5}Si{sub 3} phase.

2008-04-15

124

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...

2006-09-01

125

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

126

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current densities are ...

2005-01-01

127

An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice  

Energy Technology Data Exchange (ETDEWEB)

The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

2007-10-15

128

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

129

Surface analysis by Fourier-transform infrared (FTIR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.

1981-08-12

130

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.

1984-10-01

131

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

132

Measurement of the relaxation time of hot electrons in laser-solid interaction at relativistic laser intensities  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.

2006-08-22

133

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

134

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

135

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

136

Search for supersymmetry in 2 different topologies with the L3 detector at Lep; Recherche de supersymetrie dans les canaux avec un ou deux leptons avec le detecteur L3 a LEP  

Energy Technology Data Exchange (ETDEWEB)

The present thesis presents two different aspects of my work in the L3 experiment, which are on one side the search for supersymmetric particles, the scalar leptons, in two different topologies 'electron + X + E' and '2 leptons + 2 photons + E', each of them being related to two theoretical SUSY models, m-SUGRA and GMSB. On the other side my work has been completed by the study of the BGO crystal electromagnetic calorimeter of L3, and the calibration of the electromagnetic calorimeter EGAP. After the essential motivations being reviewed, the production and disintegration modes are detailed concerning the scalar lepton sector at LEP. Then one presents the analysis techniques which I used to perform my selection, and also the results obtained from the data collected by L3 for center of mass energies between {radical} S =183 GeV and 202 GeV. The selection criteria that allow to isolate the events I looked for, ...

2000-11-13

137

Dynamics of a very intense pulsed electron beam  

Energy Technology Data Exchange (ETDEWEB)

A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be achieved. Such beams are of interest for the study of material property changes from short-pulse high-energy depositions and for ...

1994-12-31

138

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...

2007-08-01

139

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

140

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

141

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

142

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

143

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

144

SOME RECENT DETERMINATIONS OF ATOMIC MASSES IN THE STRONTIUM-ZIRCONIUM REGION  

Science.gov (United States)

A large double-focusing mass spectrometer was used to obtain new values for the masses of Sr/sup 86/, Sr/sup 88/, and Zr/sup 90/. Mass differences calculated from these values are found to be in better agreement with nuclear transmutation information than were previous mass spectroscopically derived values. (auth)

1960-06-01

145

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

146

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

147

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

148

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

149

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

150

Highly efficient ion source for analysis of transuranium elements  

Energy Technology Data Exchange (ETDEWEB)

Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.

1987-01-01

151

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

152

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

153

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

154

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

155

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

156

Cylinder drift chamber with three-dimensional data output  

Science.gov (United States)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

1995-03-01

157

Cylinder drift chamber with three-dimensional data output  

International Nuclear Information System (INIS)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

158

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

159

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

160

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

161

Application of neural networks to pulse-shape analysis of Bragg curves  

Energy Technology Data Exchange (ETDEWEB)

A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.

2006-01-15

162

An emulation and management software for MCA with 64 independent coded inputs  

International Nuclear Information System (INIS)

A Software for the Neutron Scattering time-of-flight Spectrometer with 64 independent coded inputs is preset. It performs data acquirement and management. The work platform of the software is the Windows 98 and programmed with Visual Basic 6.0. It supports 64 x 1024 channel analyzer computer system. The friendly interface, convenient operation and high reliability are advantages of the Software

2000-09-07

163

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

164

X-ray microanalysis of Al/Zr multilayers in the transmission electron microscope  

International Nuclear Information System (INIS)

A one-nanometer scale transmission electron microscope electron probe X-ray microanalysis characterization of as-deposited and annealed aluminum--11.5 at.% zirconium multilayer samples in cross-section synthesized by magnetron sputtering is reported on here. Composition line profiles were acquired across Zr layers in as-deposited material and samples isochronally annealed in a differential scanning calorimeter to temperatures of 290 C and 485 C. A spatial resolution of approximately 1.5 to 2.0 nm was achieved in these experiments and will be improved by deconvolution of the instrumental electron probe function from the data. The as-deposited structure consisted of crystalline Al and Zr layers with thin amorphous layers at the Al/Zr interfaces. The amorphous interface layers increased in thickness upon annealing to 290 C. Additionally, at 290 C a metastable cubic alloy forms at the Zr deposited on Al interface. Upon heating to 485 C a multilayer of Al and metastable ...

1997-04-04

165

Thermogravimetric and specific heat determinations of a commercial reconcentrated sample of ulexite, between room temperature and 1,000 degree centigree; Determinaciones termogravimetricas y de calor especifico de un concentrado comercial de ulexita, entre temperature ambiente y 1.000 grados centigrados  

Energy Technology Data Exchange (ETDEWEB)

The important amount of hydration water in the ulexite (NaCaN{sub 5}O{sub 9}.8H{sub 2}O), allows using calcination methods to increase its B{sub 2}O{sub 3} content. This paper analyses the thermal decomposition reaction of a preconcentrated ulexite through weight loss measurements, which occur during the heating of samples until 1000 degree centigree, Determinations of heat content at each temperature were made using an isoperibol calorimeter. The mean specific heat was calculated from these values, and its dependence on temperature was determined. The maximum weight loss was about 32.5% and the specific heat obtained was 1,13 kJ/kg 0 C for solid samples and 1,38 kJ/kg''0 C for fluid samples. The results are useful for the design of the industrial process, in order to determine the thermal requirements for heating calcined ulexite, and to obtain smelted ulexite. (Author) 19 refs.

2006-07-01

166

Thermodynamic properties of dicarbonyl rhodium o-semiquinonate complex whose crystals display photomechanical properties  

Energy Technology Data Exchange (ETDEWEB)

In an adiabatic low-pressure calorimeter, the temperature dependence of the standard molar heat capacity of paramagnetic dicarbonyl rhodium complex with o-semiquinone (CO){sub 2}Rh(SQ) has been determined in the range from T=(6 to 355)K mainly with an accuracy of about 0.3%. Over the ranges from T=(205 to 234) K, T=(266 to 315)K and T=(316 to 345)K physical transformations have been revealed and their enthalpies and entropies have been estimated. The experimental data were used to calculate the thermodynamic functions C{sub p,m}{sup o}/R,{delta}{sub 0}{sup T}H{sub m}{sup o}/(R.K),{delta}{sub 0}{sup T}S{sub m}{sup o}/R and {phi}{sub m}{sup o}={delta}{sub 0}{sup T}S{sub m}{sup o}-{delta}{sub 0}{sup T}H{sub m}{sup o}/T (where R is the universal gas constant) between T=(0 and 355)K. The fractal dimension D in the heat capacity function of the fractal variant of Debye heat capacity theory has been evaluated.

2006-06-15

167

TPX Neutral Beam Injection System design  

International Nuclear Information System (INIS)

The existing Tokamak Fusion Test Reactor Neutral Beam system is proposed to be modified for long pulse operation on the Tokamak Physics Experiment (TPX). Day one of TPX will call for one TFTR beamline modified for 1000 second pulse lengths oriented co-directional to the plasma current. The system design will be capable of accommodating an additional co-directional and a single counter directional beamline. For the TPX conceptual design, every attempt was made to use existing Neutral Beam hardware, plant facilities, auxiliary systems, service infrastructure, and control systems. This paper describes the moderate modifications required to the power systems, the ion sources, and the beam impinged surfaces of the ion dumps, the calorimeters, the various beam scrapers, and the neutralizers. Also described are the minimal modifications required to the vacuum, cryogenic, and gas systems and the major modification of replacing the beamline-torus duct in its entirety. ...

1993-10-11

168

Study of in-medium $\\omega$ meson properties in Ap, pA and AA collisions  

CERN Document Server

We propose to investigate the in-medium properties of vector $\\omega$ mesons at the normal nuclear density in Ap(pA) collisions and at higher density in AA collisions at the ITEP accelerator facility TWAC. Using of the inverse Ap kinematics will permit us to study the $\\omega$ meson production in a wide momentum interval included the not yet explored range of small meson momenta relative to the projectile nuclei where the mass modification effect in nuclear matter is expected to be the strongest. Momentum dependence of the in-medium $\\omega$ meson width will be studied in the traditional pA kinematics. We intend to use the electromagnetic calorimeter for reconstruction of the $\\omega$ meson invariant mass by detecting photons from the $\\omega \\to \\pi^{0}\\gamma \\to 3\\gamma$ decay. The model calculations and simulations with RQMD generator show feasibility of the proposed experiment. Available now intensity of the ion beams provides a possibility to collect ...

2008-01-01

169

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light transmittance of the SCSF-81 has been studied.

1992-10-25

170

Modified Fragmentation Function in Heavy Ion Collisions at RHIC via Direct photon-Jet Measurements  

CERN Document Server

The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from $\\pi^{0}$ trigger at the same centrality class. Within the current ...

2008-01-01

171

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the time scale of a ...

172

Heat capacity measurements of atoms and molecules adsorbed on evaporated metal films  

Energy Technology Data Exchange (ETDEWEB)

Investigations of the properties of absorbed monolayers have received great experimental and theoretical attention recently, both because of the importance of surface processes in practical applications such as catalysis, and the importance of such systems to the understanding of the fundamentals of thermodynamics in two dimensions. We have adapted the composite bolometer technology to the construction of microcalorimeters. For these calorimeters, the adsorption substrate is an evaporated film deposited on one surface of an optically polished sapphire wafer. This approach has allowed us to make the first measurements of the heat capacity of submonolayer films of /sup 4/He adsorbed on metallic films. In contrast to measurements of /sup 4/He adsorbed on all other insulating substrates, we have shown that /sup 4/He on silver films occupies a two-dimensional gas phase over a broad range of coverages and temperatures. Our apparatus has been used to study the heat ...

1989-05-01

173

Enthalpy measurements of La{sub 2}Te{sub 3}O{sub 9} and La{sub 2}Te{sub 4}O{sub 11}  

Energy Technology Data Exchange (ETDEWEB)

Enthalpy increment measurements on La{sub 2}Te{sub 3}O{sub 9}(s) and La{sub 2}Te{sub 4}O{sub 11}(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H{sup o}(T) - H{sup o}(298.15 K) (J mol{sup -1}) = 360.70T + 0.00409T {sup 2} + 133.568 x 10{sup 5}/T - 149 923 (373 {<=} T (K) {<=} 936) for La{sub 2}Te{sub 3}O{sub 9} and H{sup o}(T) - H{sup o}(298.15 K) (J mol{sup -1}) = 331.927T + 0.0549T {sup 2} + 29.3623 x 10{sup 5}/T - 114 587 (373 {<=} T (K) {<=} 936) for La{sub 2}Te{sub 4}O{sub 11}.

2007-02-01

174

Enthalpy measurements of La_2Te_3O_9 and La_2Te_4O_1_1  

International Nuclear Information System (INIS)

Enthalpy increment measurements on La_2Te_3O_9(s) and La_2Te_4O_1_1(s) were carried out using a Calvet micro-calorimeter. The enthalpy values were analyzed using the non-linear curve fitting method. The dependence of enthalpy increments with temperature was given as: H"o(T) - H"o(298.15 K) (J mol"-"1) = 360.70T + 0.00409T "2 + 133.568 x 10"5/T - 149 923 (373 #<=# T (K) #<=# 936) for La_2Te_3O_9 and H"o(T) - H"o(298.15 K) (J mol"-"1) = 331.927T + 0.0549T "2 + 29.3623 x 10"5/T - 114 587 (373 #<=# T (K) #<=# 936) for La_2Te_4O_1_1.

2007-02-01

175

Emittance of boehmite and alumina films on 6061 aluminium alloy between 295 and 773 K  

Energy Technology Data Exchange (ETDEWEB)

The total hemispherical emittance of an oxide film that formed on 6061-T6 aluminium alloy parts in the Tower Shielding Reactor-II at Oak Ridge National Laboratory was measured from 295 to 773 K using an emissometer and/or a calorimeter. The emittance of this film was critically needed for heat transfer calculations in a simulated loss-of-coolant accident of the reactor. X-ray diffraction analysis identified the film as boehmite (Al{sub 2}O{sub 3} {times} H{sub 2}O), which dehydrated to alumina (Al{sub 2}O{sub 3}) upon heating above 473 K. The measured emittances for the alumina film are in excellent agreement with published values for anodized aluminum films and for bulk alumina. Published values of the emittance of boehmite could not be found for comparison, but evidence is presented that some anodization processes for aluminum yield boehmite and not alumina films.

1991-02-01

176

ELECTROMAGNETIC CALORIMETER (ECAL)  

CERN Document Server

ECAL Barrel (EB) As already mentioned in June, the Barrel ECAL is fully commissioned and routinely used during CRUZET runs.  Good progress has been made in the last months to ensure a stable and fully reliable operation, in particular for the Trigger path. More details can be found in the DPG report in this bulletin.     ECAL Endcaps (EE) In the June CMS bulletin, it had been announced that the Dee’s mechanical assembly had been finished end of May. However the electronics integration was still going on for the first Dee. The Summer has seen a spectacular breakthrough of the Endcap project. The electronics integration of Dee1 was completed early July, and this first Dee was transported to point 5 on July 8th. The completion of the three other Dees followed at a pace of one per week. In all cases the quality of the detector as measured in the assembly center was excellent, with all channels active and  the expected noise performance (see ...

177

Combustion of chemical substances. Fire characteristics and smoke gas components in large-scale experiments  

Energy Technology Data Exchange (ETDEWEB)

This report describes the combustion experiments performed using the SP Industry Calorimeter. In addition to measuring parameters such as heat release rate (HRR), mass loss rate, effective heat of combustion and smoke obscuration, considerable effort was put into the characterisation of the smoke gases in order to obtain a basis for evaluations of the toxic potency of the smoke. The materials studied were Nylon 66, polypropene, polystyrene (with and without fire retardant, respectively), PVC and chlorobenzene. A total of 19 large-scale, well ventilated combustions were carried out. The mass of sample burned ranged from 20 kg to 125 kg in an experiment. A procedure was designed for cleaning the smoke gas duct between experiments and was found to be effective. Measurements were carried out for the amounts of O{sub 2}, CO{sub 2}, CO, NO{sub x}, THC (unburned hydrocarbons), HCN, HCl, NH{sub 3} and individual organic compounds in the smoke. Adsorbents were used for the ...

1995-12-31

178

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained ...

179

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel assemblies performed using the pilot system. The results obtained ...

2007-03-15

180

Apparent molar volumes and apparent molar heat capacities of aqueous nickel(II) nitrate, copper(II) nitrate, and zinc(II) nitrate at temperatures from (278.15 to 393.15) K at the pressure 0.35 MPa  

Energy Technology Data Exchange (ETDEWEB)

Apparent molar volumes V{sub phi} and apparent molar heat capacities C{sub p,phi} were determined for aqueous solutions of nickel(II) nitrate, copper(II) nitrate, and zinc(II) nitrate at molalities m=(0.01 to 0.5) mol {center_dot} kg{sup -1}, and at the pressure p=0.35 MPa. Solution densities obtained using a vibrating-tube densimeter at T=(278.15 to 368.15) K were used to calculate V{sub phi} values. Heat capacity measurements obtained with a twin fixed-cell, differential-output, power-compensating, temperature-scanning calorimeter at T=(278.15 to 393.15) K were used to calculate values of C{sub p,phi}. Our results were then fitted to functions of m and T and compared to literature values.

2004-05-01

181

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built and tested. The results of these test, ...

2004-10-13

182

Synthesis of novel high-voltage cathode material LiCoPO{sub 4} via rheological phase method  

Energy Technology Data Exchange (ETDEWEB)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the better crystallized ...

2010-07-23

183

Synthesis of novel high-voltage cathode material LiCoPO4 via rheological phase method  

International Nuclear Information System (INIS)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized rheological phase ...

2010-07-23

184

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...

2000-05-01

185

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and non-statistical ...

186

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University lead slowing-down ...

1992-01-01

187

Recent neutron scattering work at the University of Lowell  

International Nuclear Information System (INIS)

Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.

1981-11-23

188

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1992-01-01

189

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1991-10-01

190

Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds  

Science.gov (United States)

The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...

1990-01-01

191

High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control  

Energy Technology Data Exchange (ETDEWEB)

High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing nozzle and a quadrupolar mass ...

2004-03-31

192

Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states  

International Nuclear Information System (INIS)

The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of ...

193

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

Energy Technology Data Exchange (ETDEWEB)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

1992-06-01

194

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

International Nuclear Information System (INIS)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

195

Atomic beam spectrometer using a LiF analyzer crystal  

International Nuclear Information System (INIS)

An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an incident energy of 23 ...

1978-01-01

196

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative ...

197

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...

2000-03-21

198

Use of a new time of flight aerosol mass spectrometer for ground and airborne measurements of biogenically produced organic aerosols  

Environmental Research Database

DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...

199

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

200

Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction  

International Nuclear Information System (INIS)

The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.

2007-09-01

201

Spectra of positrons and electrons emitted in "8"8Y decay  

International Nuclear Information System (INIS)

The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.

202

Soil gamma ray spectrometry of the Buquira river basin, SP, Brazil; Gamametria de solos da bacia do rio Buquira, SP, Brazil  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)

2002-12-01

203

Search for K_S K_S in J/psi and psi(2S) decays  

CERN Document Server

The CP violating processes J/psi-->K_S K_S and psi(2S)-->K_S K_S are searched for using samples of 58 million J/psi and 14 million psi(2S) events collected with the Beijing Spectrometer at the Beijing Electron Positron Collider. No signal is observed, and upper limits on the decay branching ratios are determined to be BR(J/psi-->K_S K_S) K_S K_S) < 4.6x10^{-6} at the 95% confidence level.

2004-01-01

204

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

205

Refractometry of organosilica microspheres  

CERN Document Server

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.

2007-01-01

206

Radon grab sampling in water by means of radon transfer in activated charcoal collectors  

Energy Technology Data Exchange (ETDEWEB)

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

1999-08-01

207

Quasi-elastic electron scattering by GaAs surface  

International Nuclear Information System (INIS)

Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).

1994-03-20

208

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

209

Production of cumulative pions and kaons  

International Nuclear Information System (INIS)

#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.

1988-06-14

210

Observation of p pbar pi^0 and p pbar eta in psi' decays  

CERN Document Server

The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.

2005-01-01

211

Near-threshold production of {omega}-mesons in the pn{yields}d{omega} reaction  

Energy Technology Data Exchange (ETDEWEB)

The first measurement of the pn{yields}d{omega} total cross-section has been achieved at mean excess energies Q{approx}28 and 57 MeV by using a deuterium cluster-jet target. The momentum of the fast deuteron was measured in the ANKE spectrometer at COSY-Juelich and that of the slow ''spectator'' proton (p{sub sp}) from the pd{yields}p{sub sp}d{omega} reaction in a silicon telescope placed close to the target. The cross-sections lie above those measured for pp{yields}pp{omega} but seem to be below theoretical predictions. (orig.)

2004-09-01

212

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

213

Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight  

CERN Document Server

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.

2008-01-01

214

Low-energy fission of nuclei lighter than Hg  

International Nuclear Information System (INIS)

The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.

215

Level structure of the doubly-odd /sup 242/Am nucleus  

Energy Technology Data Exchange (ETDEWEB)

The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.

1988-06-01

216

Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.

1983-03-01

217

Improved measurement of the branching ratio of J/psi-->K_S K_L  

CERN Document Server

The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.

2004-01-01

218

Failure analysis on a ruptured petrochemical pipe  

Energy Technology Data Exchange (ETDEWEB)

The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

2010-08-15

219

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

220

Electromagnetic decay properties of multiparticle-hole states in neutron deficient Mo and Tc isotopes  

Energy Technology Data Exchange (ETDEWEB)

Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).

1995-12-31

221

Effect of the size of an artificial neural network used as pattern identifier  

Energy Technology Data Exchange (ETDEWEB)

A novel way to extract relevant parameters associated with the outgoing ions from nuclear reactions, obtained by digitizing the signals provided by a Bragg curve spectrometer (BCS) is presented. This allowed the implementation of a more thorough pulse-shape analysis. Due to the complexity of this task, it was required to take advantage of new and more powerful computational paradigms. This was fulfilled using a back-propagation artificial neural network (ANN) as a pattern identifier. Over training of ANNs is a common problem during the training stage. In the performance of the ANN there is a compromise between its size and the size of the training set. Here, this effect will be illustrated in relation to the problem of Bragg Curve (BC) identification. (Author)

2003-07-01

222

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

223

Basic Design Report of DC-TOF Inelastic Neutron Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

2006-04-15

224

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

225

State of the Art Laser Induced Breakdown Spectroscopy  

International Nuclear Information System (INIS)

Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on the environmental ...

226

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...

2009-12-01

227

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of individual fission ...

1997-05-01

228

ZnO microsheet modified TiO2 nanoparticle composite films for dye-sensitized solar cells  

British Library Electronic Table of Contents (United Kingdom)

Randomly oriented ZnO microsheets were successfully self-assembled on TiO2 nanoparticle (TN) film to act as the scattering layer via a cathodic electrodeposition process. The light scattering properties of ZnO microsheets were studied by UV-Vis spectrometer in the 400?800 nm wavelength range. It was found that ZnO microsheets exhibited excellent ability to scatter the incident light for ZnO microsheet-TiO2 nanoparticle (ZT) composite films. The results showed that dye-sensitized solar cells (DSSCs) fabricated with ZT composite films showed higher short-circuit density (J sc) and conversion efficiency than TN-based DSSCs, due to the light scattering properties of ZnO microsheets.

2010-01-01

229

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

230

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

231

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

232

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the formation of the cosmic web are different from ...

2009-01-01

233

The microscopic dynamics of condensed parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

We have measured the almost-pure incoherent scattering function of liquid and solid parahydrogen, using inelastic neutron scattering. The experiments were carried out on TOSCA, a time-of-flight, inverse-geometry, crystal-analyzer spectrometer, operating on the pulsed neutron source at ISIS (UK). The experiments have been planned taking advantage of the intrinsic incoherence introduced in the scattering process by the rotational transitions. The measured double-differential cross section gives a direct experimental access to the microscopic dynamics of condensed hydrogen. From the high-energy region of the spectrum, where the impulse approximation for the center of mass motion applies, we have been able to extract the translational mean kinetic energy. In the low-energy region, using the Gaussian approximation, we compare the experimental data in the liquid phase with the results of a model for the velocity autocorrelation function. The results are encouraging, but ...

2002-07-01

234

Ternary and quaternary fission  

Energy Technology Data Exchange (ETDEWEB)

In a systematic survey of ternary fission induced by thermal neutrons at the Lohengrin spectrometer of the ILL/Grenoble, the target nucleus {sup 249}Cf has recently been added to the list of actinides under study. Special emphasis was put on the search for the heaviest ternary particles. At the limit of detection (some 10{sup -9} per fission), the heaviest isotopes observed for {sup 249}Cf(n{sub th},f) are {sup 37}Si and {sup 37}S. Another rare process in low energy fission is quaternary fission. Here two light charged particles accompany the main fragments. The reaction {sup 233} U(n,f) has been studied at a cold neutron beam of the ILL. Two processess have to be disentangled: simultaneous and sequential quaternary fission. In the simultaneous decay the most probable combination of particles is ({alpha} + {alpha}) with a yield of {approx}10{sup -7}/fission.

2004-04-05

235

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a stable cation.

2008-01-01

236

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

237

Study of duality in the transition region at Jlab  

Energy Technology Data Exchange (ETDEWEB)

Inclusive double spin asymmetries obtained by scattering polarized electrons off polarized protons and deuterons have been analyzed to address the issue of quark-hadron duality in the polarized spin structure functions g^p_1 and g^d_1. A polarized electron beam, solid polarized NH_3 and ND_3 targets and the CEBAF Large Acceptance Spectrometer (CLAS) in Hall B were used to collect the data. The resulting g^p_1 and g^d_1 were averaged over the nucleon resonance energy region (M < W < 2.00 GeV), and three lowest lying resonances individually for tests of global and local duality.

2007-01-01

238

Spectroscopy of neutron-rich {sup 59-63}Mn isotopes  

Science.gov (United States)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a {sup 238}U target with a beam of {sup 70}Zn at an energy of E{sub lab}=460 MeV. Prompt {gamma} rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-15

239

Spectroscopy of neutron-rich "5"9"-"6"3Mn isotopes  

International Nuclear Information System (INIS)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a "2"3"8U target with a beam of "7"0Zn at an energy of E_l_a_b=460 MeV. Prompt #gamma# rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-01

240

Spectroscopic measurement of the Doppler broadening region of He II line emission of DT plasmas using impurity pellets  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.

1997-03-01

241

Silicate emission in Orion  

CERN Document Server

We present mid-infrared spectro-imagery and high-resolution spectroscopy ofthe Orion bar and of a region in the Orion nebula. These observations have beenobtained in the Guaranteed Time with the Circular Variable Filters of the ISOcamera (CAM-CVF) and with the Short Wavelength Spectrometer (SWS), on board theEuropean Infrared Space Observatory (ISO). Our data shows emission fromamorphous silicate grains from the entire HII region and around the isolatedO9.5V star Theta2 Ori A. The observed spectra can be reproduced by a mixture ofinterstellar silicate and carbon grains heated by the radiation of the hotstars present in the region. Crystalline silicates are also observed in theOrion nebula and suspected around Theta2 Ori A. They are probably ofinterstellar origin. The ionization structure and the distribution of thecarriers of the Aromatic Infrared Bands (AIBs) are briefly discussed on thebasis of the ISO observations.

2000-01-01

242

Retention of ring structure in cyclopentane and alkylcyclopentane molecular cations  

Energy Technology Data Exchange (ETDEWEB)

All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.

1980-01-01

243

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

244

Recent developments at ISOLTRAP towards a relative mass accuracy of exotic nuclei below $10^{-8}$  

CERN Document Server

During the last two years, the performance of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN (Geneva) has been considerably enhanced. Many technical improvements have been completed (i) to access nuclides that are produced in minute quantities of only 100 ions s/sup -1/, (ii) to increase the relative mass accuracy to

2003-01-01

245

Rapid determination of granisetron in human plasma by liquid chromatography coupled to tandem mass spectrometry and its application to bioequivalence study  

British Library Electronic Table of Contents (United Kingdom)

A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100ml plasma samples by liquid-liquid extraction (LLE). A Varian 1200l tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02ng/ml with a relative standard deviati...

2006-01-01

246

Radial velocities, dynamics of stars and nebulosities with GAIA and VLT-GIRAFFE  

CERN Document Server

This document is divided in two parts. The first part deals with the radial velocities (RV) distributions for B-type stars and nebulosities observed with the VLT-GIRAFFE in the Large and Small Magellanic Clouds towards the open clusters NGC2004 and NGC330. Thanks to the resolution of GIRAFFE spectra, we found that the RV distribution for the nebulosities in the LMC is bi-modal. This bi-modality can be interpreted, in term of dynamics, by the expansion of the LMC4 superbubble. The second part deals with the GAIA space mission and the determination of the radial velocities by using Radial Velocity Spectrometer (RVS) spectra. The methods to determine the radial velocities are presented as well as preliminary results on simulated RVS spectra.

2008-01-01

247

Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

248

Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

249

Polarized neutron diffraction study of CePd{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.

2004-07-15

250

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

251

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u {sup 86}Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss mesurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parameterization. The resulting prospects for reaching even more neutron-rich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1991-10-01

252

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u sup 86 Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1992-07-01

253

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u "8"6Kr beam  

International Nuclear Information System (INIS)

We have measured production cross-sections of the new neutron-rich isotopes "5"8Ti, "6"1V, "6"3Cr, "6"6Mn, "6"9Fe, "7"1Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u "8"6Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide "7"8Ni, are discussed. (orig.).

254

Neutron inelastic scattering to octupole states in single-closed-shell nuclei  

International Nuclear Information System (INIS)

Differential cross sections for the excitation of the first octupole-vibrational state in the closed-neutron-shell nuclides "8"8Sr and "9"0Zr and in the closed-proton shell-nuclei sup(116,118,120,124)Sn by 11 MeV neutrons are presented. The distorted-wave Born approximation is used to obtain deformation lengths, delta(3"-) for each state. Results are compared with earlier measurements of inelastic proton scattering to the same states. Although limited resolution in the neutron time-of-flight spectrometer complicates the interpretation of the Sn data, the overall conclusion that deltasub(nn')(3"-) approx. deltasub(pp')(3"-) is supported by all of the measurements. (orig.).

255

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

256

Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV ?-ray energies  

International Nuclear Information System (INIS)

The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.

2006-11-01

257

Mass measurement of neutron-rich isotopes from [sup 51]Ca to [sup 72]Ni  

Energy Technology Data Exchange (ETDEWEB)

The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)

1994-07-01

258

Mass measurement of neutron-rich isotopes from "5"1Ca to "7"2Ni  

International Nuclear Information System (INIS)

The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).

259

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

260

Liquid chromatography with ultraviolet and dual parallel mass spectrometric detection for analysis of vitamin D in retail fortified orange juice  

British Library Electronic Table of Contents (United Kingdom)

Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...

2011-01-01

261

KLOE-2 experiment at DA$\\Phi$NE upgraded in luminosity  

CERN Document Server

Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.

2011-01-01

262

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

263

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

264

Instrumental neutron activation analysis of copper-molybdenum ores for molybdenum content determination  

International Nuclear Information System (INIS)

An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.

265

Indirect Dark Matter Signals  

CERN Document Server

Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space.

2008-01-01

266

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

267

High resolution X ray spectroscopy in light antiprotonic atoms  

Energy Technology Data Exchange (ETDEWEB)

At the LEAR facility, CERN, antiprotonic L{alpha} transitions in light elements have been investigated with a focussing crystal spectrometer. The high resolution of the experiment allowed for the first time to resolve in p-barH the 2{sup 3}P{sub 0} state from the close lying states 2{sup 3}P{sub 2}, 2{sup 1}P{sub 1}, and 2{sup 3}P{sub 1}. In p-barD the corresponding transitions were found to be more than an order of magnitude broader. To a large extent the results for p-barH support the meson exchange model.

2000-08-15

268

First observation of psi(2S)-->K_S K_L  

CERN Document Server

The decay psi(2S)-->K_S K_L is observed for the first time using psi(2S) data collected with the Beijing Spectrometer (BESII) at the Beijing Electron Positron Collider (BEPC); the branching ratio is determined to be B(psi(2S)-->K_S K_L) = (5.24\\pm 0.47 \\pm 0.48)\\times 10^{-5}. Compared with J/psi-->K_S K_L, the psi(2S) branching ratio is enhanced relative to the prediction of the perturbative QCD ``12%'' rule. The result, together with the branching ratios of psi(2S) decays to other pseudoscalar meson pairs (\\pi^+\\pi^- and K^+K^-), is used to investigate the relative phase between the three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.

2003-01-01

269

Explosives sensor  

Energy Technology Data Exchange (ETDEWEB)

A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and advantages are discussed in ...

1987-01-01

270

Exclusive ?0 electroproduction on transversely polarized protons  

International Nuclear Information System (INIS)

The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum of the quarks to the proton spin.

2009-08-17

271

Elastic and inelastic scattering of "1"4C from medium heavy nuclei  

International Nuclear Information System (INIS)

The elastic and inelastic scattering of "1"4C at 51 MeV from targets of "4"0Ca, "5"6Fe, "6"0Ni, "6"6Zn and "8"8Sr has been measured using a Q3D spectrometer. The "1"4C-nucleus potentials have been derived by optical-model analysis of the observed elastic scattering; the inelastic scattering differential cross sections were interpreted in the distorted-wave Born approximation and also in the coupled-channels approach. The analysis yields "1"4C-nucleus potentials that closely resemble "1"2sup(,)"1"3C and "1"6O potentials. (orig.).

272

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

273

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

274

Chemical and morphological characterization of mesoporous material supported copper oxide nanoparticles for potential application  

British Library Electronic Table of Contents (United Kingdom)

SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...

2011-01-01

275

Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design.  

Science.gov (United States)

For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817

1999-03-20

276

Barium carbonate sediment sampling for inorganic dissolved carbon using isotope mass ratio spectrometer  

International Nuclear Information System (INIS)

This paperwork explain the method of water sampling to obtain the precipitate of BaCO3 solutions that will be used to analyze 13C from field work in Kelana Jaya, Selangor, Langkawi, Kedah and Taiping, Perak. The sampling involves collecting of water samples for groundwater from boreholes and surface water from canal, river, pond and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemicals used. The main purpose of this sampling is to obtain the precipitate of BaCO3 for 13C analysis of dissolved inorganic carbon (DIC). A correct sampling method according to standard is very important to ensure an accurate and precise result. With this, the data from the laboratory analysis result can be fully utilized to make the interpretation of the pollutants movement. (Author)

2009-10-06

277

Accelerator mass spectrometry: state of the art  

Energy Technology Data Exchange (ETDEWEB)

Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

1996-12-31

278

A polarized neutron reflectometry study of the spin glass freezing in a 29 nm thick AuFe film  

Energy Technology Data Exchange (ETDEWEB)

We performed polarized neutron reflectometry (PNR) experiments on a 29 nm thick Au{sub 93}Fe{sub 7} film in a temperature range from 295 K down to 2 K in a vertical magnetic field up to 6 T. These high-field experiments were performed on the C5 spectrometer in Chalk River, Canada, using a split-pair cryomagnet. The magnetization as determined by PNR can be described with a Brillouin function from 295 K down to 50 K assuming the magnetic moment of isolated Fe atoms, i.e. 4{mu}{sub B} per Fe atom. Below 50 K the onset of the spin-glass freezing is observed as a strong deviation from this Brillouin type behavior of isolated atoms.

2007-07-15

279

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

280

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

281

Thermochemistry of mixed explosives  

Energy Technology Data Exchange (ETDEWEB)

In order to predict thermal hazards of high-energy materials, accurate kinetics constants must be determined. Predictions of thermal hazards for mixtures of high-energy materials require measurements on the mixtures, because interactions among components are common. A differential-scanning calorimeter (DSC) can be used to observe rate processes directly, and isothermal methods enable detection of mechanism changes. Rate-controlling processes will change as components of a mixture are depleted, and the correct depletion function must be identified for each specific stage of a complex process. A method for kinetics measurements on mixed explosives can be demonstrated with Composition B is an approximately 60/40 mixture of RDX and TNT, and is an important military explosive. Kinetics results indicate that the mator process is the decomposition of RDX in solution in TNT with a perturbation caused by interaction between the two components. It is concluded that a ...

1982-01-01

282

The volumetric and thermochemical properties of Y(ClO_4)_3 (aq), Yb(ClO_4)_3 (aq), Dy(ClO_4)_3 (aq), and Sm(ClO_4)_3 (aq) at T=(288.15,298.15,313.15, and 328.15) K and p=0.1 MPa  

International Nuclear Information System (INIS)

Relative densities and relative massic heat capacities have been measured for aqueous solutions of Y(ClO_4)_3, Yb(ClO_4)_3, Dy(ClO_4)_3, and Sm(ClO_4)_3 at T=(288.15,298.15,313.15, and 328.15) K and p=0.1 MPa. These measurements were made in the concentration range 0.01624#<=#m/(mol#centre dot#kg"-"1)#<=#0.41822 using a Sodev 02D Vibrating Tube Densimeter and a Picker Microflow Calorimeter, respectively. To counter the potential effects of hydrolysis, aqueous solutions of the investigated salts were acidified with perchloric acid. After correcting for the presence of the acid, the measured properties were used to calculate apparent molar volumes and apparent molar heat capacities for solutions of the perchlorate salts in water. The calculated apparent molar properties were modeled at each investigated temperature using Pitzer ion interaction equations to produce estimates of apparent molar volumes and heat capacities at infinite dilution. In addition, the ...

2003-05-01

283

The neutron capture cross sections of {sup 237}Np(n,{gamma}) and {sup 240}Pu(n,{gamma}) and its relevance in the transmutation of nuclear waste  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF {sigma}(n,{gamma}) agrees within uncertainties with JENDL-3.3 and JEFF-3.1, except for a ...

2008-07-01

284

Molar heat capacities for (2-methyl-2-butanol + heptane) mixtures and cyclopentanol at temperatures from (284 to 353) K  

International Nuclear Information System (INIS)

Isobaric specific heat capacities were measured for (2-methyl-2-butanol + heptane) mixtures and cyclopentanol within the temperature range from (284 to 353) K, and for 2-methyl-2-butanol in the (284 to 368) K temperature interval by means of a differential scanning calorimeter. The excess molar heat capacities were calculated from the experimental results. For the temperature range from (284 to 287) K, the excess molar heat capacity is S-shaped with negative values in the 2-methyl-2-butanol rich region and with small negative values at low alcohol concentrations at temperatures from (295 to 353) K. The excess molar heat capacities are positive for all compositions under test at temperatures from (288 to 294) K. The results are explained in terms of the influence of the molecular size and configuration of the alkanols on their self-association capability and of the change in molecular structure of the (2-methyl-2-butanol + heptane) mixtures. The differences between ...

2009-03-01

285

Long pulse chemical laser. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD funded theoretical study ...

1989-02-01

286

Isothermal heat measurements of TBP-nitric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

Net heats of reaction were measured in an isothermal calorimeter for both single phase (organic) and two phase (organic and aqueous) TBP/HNO{sub 3} reacting solutions at temperatures above 100 C. The oxidation rate constant was determined to be 5.4E-4 min{sup {minus}1} at 110 C for an open ``vented`` system as compared to 1.33 E-3 min{sup {minus}1} in the closed system. The heat released per unit material oxidized was also reduced. The oxidation in both phases was found to be first order in nitric acid and pseudo-zero order in butylnitrate and water. The hydrolysis (esterification) rate constant determined by Nichols` (1.33E-3 min{sup {minus}1}) fit the experimental data from this work well. Forced evaporation of the volatile components by the product gases from oxidation resulted in a cooling mechanism which more than balanced the heat from the oxidation reaction in the two-phased systems. Rate expressions were derived and rate constants determined for both the ...

1994-12-16

287

Comparisons of graphite and spinel Li1.33Ti1.67O4 as anode materials for rechargeable lithium-ion batteries  

International Nuclear Information System (INIS)

The aim of this work was to compare the electrochemical behaviors and safety performance of graphite and the lithium titanate spinel Li1.33Ti1.67O4 with half-cells versus Li metal. Their electrochemical properties in 1 M LiPF6/EC + DEC (1:1 w/w) or 1 M LiPF6/PC + DEC (1:1 w/w) at room and elevated temperatures (30 and 60 deg C) have been studied using galvanostatic cycling. At 30 deg C graphite has higher reversible capacity than Li1.33Ti1.67O4 when using the LiPF6/EC + DEC as electrolyte. At 60 deg C graphite declines in cell capacity yet Li1.33Ti1.67O4 remains almost unchanged. In a propylene carbonate (PC) containing electrolyte, graphite electrode exfoliates and loses its mechanical integrity while Li1.33Ti1.67O4 electrode is very stable. An accelerating rate calorimeter (ARC) and microcalorimeter have been used to compare the thermal stability of lithiated lithium titanate spinel and graphite. Results show that Li1.33Ti1.67O4 may be used as an alternative ...

2005-07-25

288

A detailed analysis of the properties of radiolyzed proteinaceous amino acids  

International Nuclear Information System (INIS)

The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. Such correlation instead does not exist between the N_#gamma# parameter and the ...

2011-03-01

289

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...

2010-10-01

290

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...

2000-07-01

291

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer  

International Nuclear Information System (INIS)

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the "6"3"-"6"6Fe and "6"4"-"6"7Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for "6"6Fe and "6"7Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of "6"5Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in "6"7Co is confirmed. Relative mass uncertainties as low as 4x10"-"8 are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of "6"4Co, where a 5#sigma# deviation is observed. Using these data the two neutron separation energies S_2_n are calculated. However, the large error bars in the mass values ...

2010-04-01

292

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the ...

1997-05-01

293

Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K  

Energy Technology Data Exchange (ETDEWEB)

Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO[sub 2] absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the [ital P] branch of the fundamental absorption band (2150--1950 cm[sup [minus]1]) while the CO[sub 2] vibrational-rotational lines were from the far wing of the [ital R] branch of the [nu][sub 3] fundamental band (2395--2380 cm[sup [minus]1]). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO[sub 2]/N[sub 2] gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak ...

1994-11-01

294

Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K  

International Nuclear Information System (INIS)

Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO_2 absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the P branch of the fundamental absorption band (2150--1950 cm"-"1) while the CO_2 vibrational-rotational lines were from the far wing of the R branch of the #nu#_3 fundamental band (2395--2380 cm"-"1). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO_2/N_2 gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak overlap. Line strength measurements were made from the corrected ...

295

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial steps provide input to the rule base. The overall analysis ...

296

Development of a Bragg curve spectrometer (BCS) for fragment spectroscopy from neutron and proton induced reactions  

Energy Technology Data Exchange (ETDEWEB)

Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using {sup 241}Am {alpha} ...

2002-09-01

297

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...

2005-01-15

298

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the ...

1988-11-01

299

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation measurement capabilities ...

1995-11-01

300

Absence of isoscalar monopole strength in {sup 56}Fe and {sup 58}Ni  

Energy Technology Data Exchange (ETDEWEB)

Measurements with 240 MeV {alpha} particle inelastic scattering with excellent peak/background ratios at small scattering angles including 0{degrees} were made on {sup 56}Fe and {sup 58}Ni using the multipole-dipole-multipole spectrometer at Texas A&M University. Beam was delivered to the spectrometer through a beam analysis system having two bends of 88{degrees} and 87{degrees} respectively. A slit placed after the first 88{degrees} bend was used to define the beam. Slits placed after the second bend (87{degrees}) were used to eliminate slit scattered particles. Comparison of the results of a multiple peak fit to the{sup 58}Ni spectra after continuum subtraction to DWBA calculations revealed about 32% of the E0 EWSR and 58% of the E2 EWSR in the peak, in agreement with previous works. Fits to the angular distribution of the continuum for E{sub x} = 25 MeV show that <15% of the E0 EWSR is present in the continuum. Hence 50% of the EO ...

1995-10-01

301

[Hadroproduction of charmed and bottom mesons (Fermilab experiment E-653): Progress report, June 13, 1983--June 14, 1984  

Energy Technology Data Exchange (ETDEWEB)

(I)Results are given for photoproduction of the D{sup *} at 103 GeV. Clean signals are seen for the decay D{sup *{+-}} {yields} {pi}{sup {+-}}D{sup 0} with the D{sup 0} decaying into both K{sup {-+}}{pi}{sup {+-}} and K{sup {-+}}{pi}{sup {+-}}{pi}{sup 0}. Analysis of the Dalitz plot for the K{pi}{pi} mode gives branching fractions (BFs) for K{sup {minus}}{rho}{sup +}, K{sup *{minus}}{pi}{sup +}, and {anti K}{sup *0}{pi}{sup 0} final states. The BF for D{sup 0} {yields} K{sup {minus}}{rho}{sup +}, much lower than a previous result, is in approximate agreement with the value expected for an l=1/2 final state. (II)Inelastic and elastic J/{psi} photoproduction on H is investigated at 103 GeV. The inelastic cross section with E{sub {psi}}/E{sub {gamma}} {lt} 0.9 is significantly lower than the corresponding result for muoproduction on Fe targets, but consistent with second-order perturbative QCD calculation. The mean p{sub +} of inelastic events is larger than that of elastic events. ...

1984-12-31

302

Thermodynamics of (1-chloronaphthalene + n-alkane): Excess enthalpies, excess volumes and excess heat capacities  

Energy Technology Data Exchange (ETDEWEB)

A flow microcalorimeter of the Picker design has been used to measure molar excess enthalpies at 298.15 K of the seven binary liquid mixtures 1-chloronaphthalene + n-hexane, + n-heptane, + n-octane, + n-decane, + n-dodecane, + n-pentadecane, and + n-hexadecane. Experiments were performed in the discontinuous mode, covering essentially the whole composition range. The overall imprecision of the measurements is characterized by standard deviations from Redlich-Kister type smoothing equations of generally less than +- 1 per cent of the maximum value Hsub(max)sup(E) of the excess enthalpy (with respect to mole fraction). The most striking feature is that for 6 <= n <= 16 (n denotes the number of C-atoms of the n-alkane) Hsub(max)sup(E) decreases with increasing n, the correlation being approximately linear. - For the mixtures 1-chloronaphthalene + n-hexane, + n-heptane, + n-octane, + n-dodecane, + n-pentadecane, and + n-hexadecane molar excess volumes Vsup(E) at 298.15 K were ...

1981-09-01

303

Thermodynamic investigation of crystalline K{sub 2}Cr{sub 2}O{sub 7} and aqueous K{sub 2}Cr{sub 2}O{sub 7} solution  

Energy Technology Data Exchange (ETDEWEB)

The molar heat capacities (C{sub p,m}) of crystalline potassium dichromate (K{sub 2}Cr{sub 2}O{sub 7} (cr)) and aqueous K{sub 2}Cr{sub 2}O{sub 7} solution (0.1699 mol.kg{sup -1}) were measured in the temperature range from 100 to 390 K and from 80 to 370 K by an automatic adiabatic calorimeter equipped with a small cell of internal volume of 6 cm{sup 3}, respectively. No phase transition took place in the temperature range from 100 to 390 K for K{sub 2}Cr{sub 2}O{sub 7} (cr). The relationships of C{sub p,m} of K{sub 2}Cr{sub 2}O{sub 7} (cr) with respect to T were established to be C{sub p,m} 177.53 + 161.92 X - 138.14 X{sup 2} - 209.67 X{sup 3} + 160.35 X{sup 4} + 137.44 X{sup 5} - 41.291 X{sup 6} and C{sub p,m} 177.52 + 171.66 X -149.59 X{sup 2} - 246.17 X{sup 3} + 194.79 X{sup 4} + 167.30 X{sup 5} - 64.368 X{sup 6} (X=(T-245.00)/145.00) for Series 1 and Series 2 experiments, respectively. No phase transition took place for the solution from 80 to 270 K. The ...

2003-07-01

304

XPS study on the correlation between chemical state and oxygen-sensing properties of an iron oxide thin film  

International Nuclear Information System (INIS)

We have studied the correlation between the chemical state and the oxygen-sensing properties of an iron oxide thin film using a setup that allows simultaneous sensor resistance measurements and X-ray photoelectron spectroscopy (XPS) data acquisition. The gas exposures were performed at the highest operating pressure of the XPS spectrometer at a controlled sample temperature which allows direct comparison between the sensor response and the chemical state of the surface. The iron oxide film was modified by a sequence of argon ion sputtering steps and the induced changes in the chemical state, resistance, and sensitivity to oxygen were investigated. The sputtering was found to reduce the iron from the Fe"3"+ to the Fe"2"+ state and to decrease the sensor resistance. The measured sensitivity to oxygen first increased by a factor of two but then collapsed to its original level. The mechanism for oxygen sensing was found to be filling of the oxygen vacancies in the ...

2007-10-15

305

Thermal-neutron capture cross section and resonance integral of americium-241  

International Nuclear Information System (INIS)

The thermal-neutron capture cross section (#sigma#_0_,_g) and the resonance integral (I_0_,_g) leading to the ground state of "2"4"2Am were measured by an activation method for neutron capture by "2"4"1Am. A method with gadolinium, which was similar to the cadmium difference method, was used to measure the cross section #sigma#_0_,_g with attention to resonances of "2"4"1Am. Americium chloride samples containing "2"4"1Am radioisotope were irradiated for 68 h in the long-irradiation plug of the Kyoto University Research Reactor, KUR. Wires of Co/Al and Au/Al alloys were used as monitors to determine thermal-neutron fluxes and epithermal Westcott's indexes at the irradiation positions. An #alpha#-ray spectrometer was used to measure the activity ratios of "2"4"2Cm to "2"4"1Am. On the basis of Westcott's convention, the #sigma#_0_,_g and I_0_,_g values were determined as 628#+-#22 b and 3.5#+-#0.3 kb, respectively. (author)

2007-12-01

306

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas ...

2005-03-17

307

The influence of electromagnetic field irradiated by high-voltage transmission lines on properties of cells.  

Science.gov (United States)

The influence of low-frequency electromagnetic field irradiating by high-voltage transmission lines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmission lines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this electromagnetic field. The spectra of infrared absorption for the general ...

2005-01-01

308

TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams  

International Nuclear Information System (INIS)

A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in very good agreement with both theoretical ...

2010-03-11

309

Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft  

Energy Technology Data Exchange (ETDEWEB)

Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding the directivity of hard X-ray sources in ...

1992-01-01

310

Selective adsorption of uranium on activated charcoal from electrolytic aqueous solutions  

Energy Technology Data Exchange (ETDEWEB)

Adsorption of uranium onto various solids is important from purification, environmental, and radioactive waste disposal points of view. Adsorption of uranium on activated charcoal has been studied as a function of shaking time, amount of adsorbent, pH, concentration of adsorbate, and temperature. Uranium adsorption obeys the Langmuir isotherm. {Delta}H{degrees} and {Delta}S{degrees} were calculated from the slope and intercept of plots ln K{sub D} vs 1/T. The influence of different anions and cations on uranium adsorption has been examined. The adsorption of other metal ions on activated charcoal has been studied under specified conditions to check its selectivity; consequently, uranium was removed from Cs, Ba, Zn, and Co. More than 98% adsorbed uranium on activated charcoal can be recovered with 65 ml of 3 M HNO{sub 3} solution. A wavelength dispersive x-ray fluorescence spectrometer was used for measuring uranium concentration.

1992-02-01

311

Radiometric analysis of raw materials and end products in the Turkish ceramics industry  

International Nuclear Information System (INIS)

This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. The results suggest ...

2011-05-01

312

Radiations emitted in the decay of /sup 165/Er: A promising medical radionuclide  

Science.gov (United States)

The 10.3-h /sup 165/Er, decaying by electron capture to stable /sup 165/Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in /sup 165/Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of /sup 169/Er and /sup 171/Er radioactive impurities in the reactor-produced /sup 165/Er sample are experimentally determined. Whole-body dose estimates for /sup 165/Er are given. These compare favorably with /sup 99/Tc dose.

1977-05-01

313

Radiations emitted in the decay of "1"6"5Er: A promising medical radionuclide  

International Nuclear Information System (INIS)

The 10.3-h "1"6"5Er, decaying by electron capture to stable "1"6"5Ho, offers an excellent promise for use in diagnostic nuclear medicine, especially in conjuction with multiwire proportional-counter cameras. Using an ultra-high-resolution Si(Li) photon spectrometer, L and K x-ray photon yields in "1"6"5Er decay have been measured. The ratio P/sub L//P/sub K/ of electron-capture probabilities in L and K shells is determined to be 0.196 +- 0.030, in good agreement with theory. Estimates of Auger electron yields and yields of very-low-energy electrons from Coster--Kronig transitions are presented. Levels of "1"6"9Er and "1"7"1Er radioactive impurities in the reactor-produced "1"6"5Er sample are experimentally determined. Whole-body dose estimates for "1"6"5Er are given. These compare favorably with "9"9Tc dose.

314

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise time of deposited gamma photons. Time ...

2000-01-01

315

Pre-transitional disk nature of the AB Aur disk  

CERN Document Server

The disk around AB Aur was imaged and resolved at 24.6\\,$\\mu$m using the Cooled Mid-Infrared Camera and Spectrometer on the 8.2m Subaru Telescope. The gaussian full-width at half-maximum of the source size is estimated to be 90 $\\pm$ 6 AU, indicating that the disk extends further out at 24.6\\,$\\mu$m than at shorter wavelengths. In order to interpret the extended 24.6\\,$\\mu$m image, we consider a disk with a reduced surface density within a boundary radius $R_c$, which is motivated by radio observations that suggest a reduced inner region within about 100 AU from the star. Introducing the surface density reduction factor $f_c$ for the inner disk, we determine that the best match with the observed radial intensity profile at 24.6\\,$\\mu$m is achieved with $R_c$=88 AU and $f_c$=0.01. We suggest that the extended emission at 24.6\\,$\\mu$m is due to the enhanced emission from a wall-like structure at the boundary radius (the inner edge of the outer disk), which ...

2010-01-01

316

Population of nuclei close to N=Z line for A{approx}100 through emission of complex fragments and light charged particles  

Energy Technology Data Exchange (ETDEWEB)

High spin states of the proton rich nuclei in the mass region A {approx} 100 have been studied at the GASP spectrometer through the evaporation of light charged particles and heavier ions detected in the 4{pi} Si-ball Isis. Rear side injection and pulse shape analysis have allowed a good discrimination among protons, alpha particles and heavy ions up to C. Of the several nuclei populated in the reactions we will discuss here the high spin states of {sup 105} Sn. In addition to an extension of the spherical level, scheme, a regular sequence of dipole transitions has been found, The states of the dipole band are suggested to be built on a neutron h{sup 2}{sub 11/2} excitation coupled to proton particle-hole states, which polarize the core to a slightly prolate shape. The experimental results are in agreement with the prediction of tilted axis cranking calculations, which satisfactorily explain the properties of the band. (author) 17 refs., 4 figs.

1997-12-31

317

On-line analysis of chemical composition using an FT-Raman spectrometer in the near-ir  

Science.gov (United States)

Newly commercialized Fourier transform Raman spectroscopic instrumentation provides a simpler alternative for vibrational spectroscopic analysis. Instrument vendors currently design for laboratory use, but there are many potential process applications of these stable, easy to use instruments. Raman spectroscopy is highly suited to analysis of aqueous samples. Near infrared excitation minimized fluorescence interference and allows for remote operation via fiber optic probes. The Department of Energy has funded research at the Measurement and Control Center to establish the utility of this method for on-line composition analysis in distillation columns. Laboratory evaluation and instrument employs an air-cooled laser and a thermoelectrically cooled detector. The device is mounted on a three by foot cart for convenient location in control rooms. Current fiber optic extension cables allow for analysis in a cell thirty five meters from the instrument. Application of the device to acid an ...

1992-01-01

318

Method of calibration to correct for cloud-induced wavelength shifts in the Aura satellite's Ozone Monitoring Instrument  

Science.gov (United States)

The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these wavelength variations ...

2006-05-01

319

Measurement of the antiproton/proton ratio at few-TeV energies with the ARGO-YBJ experiment  

CERN Document Server

Cosmic ray antiprotons provide an important probe for the study of cosmic-ray propagation in the interstellar space and to investigate the existence of Galactic dark matter. Cosmic rays are hampered by the Moon, therefore a deficit of cosmic rays in its direction is expected (the so-called "Moon shadow"). The Earth-Moon system acts as a magnetic spectrometer. In fact, due to the geomagnetic field the center of the Moon shifts westward by an amount depending on the primary cosmic ray energy. Paths of primary antiprotons are therefore deflected in an opposite sense in their way to the Earth. This effect allows, in principle, the search of antiparticles in the opposite direction of the observed Moon shadow. The ARGO-YBJ experiment, in stable data taking since November 2007 with an energy threshold of a few hundreds of GeV, is observing the Moon shadow with high statistical significance. Using about 1 year data, an upper limit of the antip/p flux ratio in the few-TeV ...

2009-01-01

320

Measurement of the Electron Affinities of Indium and Thallium  

Energy Technology Data Exchange (ETDEWEB)

The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental measurements will be compared to several recent theoretical predictions.

1999-03-20

321

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality assurance because (1) a ...

1978-01-01

322

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, was used to produce ...

1984-01-01

323

Mass measurements of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc and their impact on the rp-process  

Energy Technology Data Exchange (ETDEWEB)

The masses of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, and the issue of a potential Zr-Nb cycle is addressed.

2010-07-01

324

Mass measurements of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc and their impact on the rp-process  

International Nuclear Information System (INIS)

The masses of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor of 30. Results of measurements and calculations are presented, and the issue of a potential Zr-Nb cycle is addressed.

2010-03-15

325

Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects  

CERN Document Server

Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical basis. We interpret this enhancement in ...

2008-01-01

326

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over conventional detectors. Detector fabrication procedures, I-V and C-V ...

1992-10-01

327

K beta X-ray transition energies of M-shell-ionized ions of Ti through Ni in a plasma  

Energy Technology Data Exchange (ETDEWEB)

K beta X-ray lines from partially M-shell-ionized ions of titanium through nickel which are produced in vacuum-spark plasmas have been observed systematically for the first time, using a high-resolution curved-crystal spectrometer. Each K beta line is clearly separated into its corresponding charge state. As a result, it is possible to measure the K beta-type transition energies of the M-shell-ionized ions. The transition energies accurately determined are compared with those calculated for iron ions, and the agreement is excellent except for ions having some additional 3d outer-shell electrons or 3s inner-shell vacancies. The square root of the K beta transition frequency is expressed as a linear function of the nuclear charge for isoelectronic sequences. The effective nuclear charges have been also determined for each K beta transition. The 3p electrons do not affect the effective nuclear charges. 10 references.

1985-05-01

328

Ion-induced M X-ray emission from heavy lanthanides  

Energy Technology Data Exchange (ETDEWEB)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and /sup 3/He ions of 3 MeV/amu, and M/sub ..cap alpha../ and M/sub ..beta../ X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and /sup 3/He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M/sub ..cap alpha../ and M/sub ..beta../ lines is for radiative transition after the refilling of the 4f orbit (3d/sup -1/4f/sup n+1/ -> 4f/sup n/) where n denotes the number of 4f electrons of the target atom before ionization.

1987-12-01

329

Interaction of 8 MeV /sup 12/C with /sup 88/Sr; neutron transfer, inelastic scattering and spin alignment of the 2/sup +/ state of /sup 12/C  

Energy Technology Data Exchange (ETDEWEB)

Using a Q3D magnetic spectrometer the elastic and inelastic scattering of /sup 12/C on /sup 88/Sr and the neutron pick-up (/sup 12/C, /sup 13/C) has been studied. The spin alignment of the inelastically excited 2/sup +/ state of /sup 12/C (4.43 MeV) has been deduced from the line shapes broadened by the ..gamma..-decay in flight. Thus for each m-substate a full angular distribution was obtained. The m = 1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in the m-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.

1982-04-01

330

Integration and Testing of the Micro-X Rocket Payload  

Science.gov (United States)

The Micro-X instrument is a rocket borne, X-ray imaging spectrometer planned for launch in October 2011. An array of 128 Transition Edge Sensors (TESs) on a 600 micron pitch will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. X-rays will be focused onto the TES array by a conically approximated Wolter optic with an effective area of 300 cm^2 giving the instrument a field of view of 11.8 arcmin. This performance will constitute a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat bath, and will be read out by a SQUID time division multiplexer. The first flight of the Micro-X instrument will observe the Puppis A supernova remnant. Future targets include the core of the Virgo cluster and ...

2011-05-01

331

Infrared Observations During the Secondary Eclipse of HD 209458b I. 3.6-Micron Occultation Spectroscopy Using the VLT  

CERN Document Server

We search for an infrared signature of the transiting extrasolar planet HD 209458b during secondary eclipse. Our method, which we call `occultation spectroscopy,' searches for the disappearance and reappearance of weak spectral features due to the exoplanet as it passes behind the star and later reappears. We argue that at the longest infrared wavelengths, this technique becomes preferable to conventional `transit spectroscopy'. We observed the system in the wing of the strong nu-3 band of methane near 3.6 microns during two secondary eclipses, using the VLT/ISAAC spectrometer at a spectral resolution of 3300. Our analysis, which utilizes a model template spectrum, achieves sufficient precision to expect detection of the spectral structure predicted by an irradiated, low-opacity (cloudless), low-albedo, thermochemical equilibrium model for the exoplanet atmosphere. However, our observations show no evidence for the presence of this spectrum from the exoplanet, with ...

2003-01-01

332

Inclusive K{sup +}-meson production in proton-nucleus interactions  

Energy Technology Data Exchange (ETDEWEB)

The production of K{sup +}-mesons in pA(A=D,C,Cu,Ag,Au) collisions has been investigated at the COoler SYnchrotron COSY-Juelich for beam energies T{sub p}=1.0-2.3 GeV. Double differential inclusive pC cross-sections at forward angles {theta}{sub K+}<12 as well as the target mass dependence of the K{sup +} momentum spectra have been measured with the ANKE spectrometer. Far below the free NNthreshold at T{sub NN}=1.58 GeV the spectra reveal a high degree of collectivity in the target nucleus. From the target mass dependence of the cross-sections at higher energies, the repulsive in-medium potential of the K{sup +}-mesons can be deduced. Using pNcross-section parameterisations from the literature and our measured pD data we derive a cross-section ratio {sigma}(pn{yields}K{sup +}X)/{sigma}(pp{yields}K{sup +}X) {proportional_to}(3-4). (orig.)

2004-11-01

333

Formation of Si-nanoparticles in a microwave reactor: Comparison between experiments and modelling  

International Nuclear Information System (INIS)

The formation and growth of silicon-nanoparticles from silane in a microwave reactor was investigated. Experiments were performed for the following conditions: precursor concentration 380-2530 ppm, pressures of 20-30 mbar, microwave powers 120-300 W. The formed particles were examined in-situ with a particle mass spectrometer. Additionally, particles were collected on grids and analyzed by transmission electron microscopy, X-ray diffraction, and by determining the specific surface area by BET. The particle size was found to be in the range of 5-8 nm in diameter. A simple model was used to simulate the particle formation processes taking place inside the reactor. The microwave energy coupled into the reactor flow was treated as a spatially distributed energy source resulting in a local temperature increase. The particles were assumed to have a monodisperse size distribution. To allow an approximation of their shape they were characterized by their volume and surface ...

2005-02-01

334

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of {sup 86}Zr and {sup 85}Nb were measured and found to be in agreement with the values obtained at JYFLTRAP. The experiment as well as preliminary data on ...

2009-07-01

335

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the masses of "8"6Zr and "8"5Nb were measured and found to be in agreement with the values obtained at JYFLTRAP. The experiment as well as preliminary data on mass values, separation ...

2009-03-16

336

FT-IR spectroscopic studies of polycyclic aromatic hydrocarbons  

International Nuclear Information System (INIS)

Proper assessment of the hypothesis which correlates polycyclic aromatic hydrocarbons (PAHs) with the unidentified infrared emission bands requires additional experimental laboratory data. In order to address this need, thermal infrared emission studies were performed on a subset of PAHs suggested to be of astrophysical importance. It was proposed that infrared emission from interstellar PAHs occurs following absorption of an ultraviolet photon. Since energy transfer to the ground electronic state can be rapid for a species in which intersystem crossing is negligible, the emission spectrum may be viewed as resulting from an equilibrium vibrational temperature (Leger and d'Hendecourt, 1987). This has been the basis for using infrared absorption spectra to calculate the corresponding emission spectra at various temperatures. These calculations were made using room temperature infrared absorption coefficients instead of those at the temperature of interest because of the latter's ...

1990-04-01

337

Establishing a Connection Between Active Region Outflows and the Solar Wind: Abundance Measurements with EIS/Hinode  

CERN Document Server

One of the most interesting discoveries of the X-ray Telescope and EUV Imaging Spectrometer (EIS) on board the Hinode solar observatory is the presence of persistent high temperature high speed outflows from the edges of active regions. Measurements by EIS indicate that the outflows reach velocities of 50 km/s with spectral line asymmetries approaching 200 km/s. It has been suggested that these outflows may lie on open field lines that connect to the heliosphere, and that they could potentially be a significant source of the slow speed solar wind. A direct link has been difficult to establish, however. In this letter, we use EIS measurements of spectral line intensities that are sensitive to changes in the relative abundance of Si and S as a result of the first ionization potential (FIP) effect, to measure the chemical composition in the outflow regions of AR 10978 over a period of 5 days in December 2007. We find that Si is always enhanced over S by a factor of ...

2010-01-01

338

Energetic electrons in impulsive and extended solar flares as deduced from flux correlations between hard X-rays and microwaves  

Energy Technology Data Exchange (ETDEWEB)

The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or loops. 59 references.

1988-01-01

339

Effects of relativity and 'atomic structure' in the KLL Auger spectrum of "8"8Sr generated in the EC-decay of "8"8Y  

International Nuclear Information System (INIS)

The KLL Auger electron spectrum of "8"8Sr generated in the EC-decay of "8"8Y has been analyzed at the instrumental resolution of 11 eV using a combined electrostatic spectrometer. Energies and relative intensities of the all nine transitions were determined and compared with theoretical predictions. Our value of 12067.3(12) eV measured for the absolute energy of the dominant KL_2L_3("1D_2) transition was found to be higher by 7.4 eV (i.e., more than 3#sigma#) than that one obtained in a measurement with external excitation. The discrepancy indicates substantial influence of the 'atomic structure effect' on absolute transition energies in our experiment. Very good agreement of the measured 0.14(3) and predicted 0.12 values for the KL_1L_2("3P_0/"1P_1) Auger transition intensity ratio clearly proved the predicted strong influence of the relativistic effects on the KL_1L_2("3P_0) transition rate even at Z = 38.

2007-08-01

340

Effects of oxygenated blending compounds on emissions from a turbo-charged direct injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

An experimental investigation was conducted to evaluate the effect of three different oxygenated compounds, diglyme, diethyl maleate and dibutyl maleate, on emissions from a Volkswagen 1.9 litre, turbocharged, direct injection diesel engine. Sampling was performed using a mini-dilution tunnel technique to obtain particulate matter and a Fourier transform infrared (FTIR) spectrometer for gaseous emissions. The particulate samples were analysed using thermal analysis and Soxhlet extraction to determine the fraction of volatile and soluble organic material respectively. All three oxygenated compounds were found to be effective at reducing particulate emissions, with the maleate compounds being more effective overall than the diglyme. Analysis of the relative contributions of changes in the soot and soluble organic fraction (SOF) to the reduction of particulate matter indicated that, for diethyl maleate and diglyme, reductions in soot were the dominant effect. No ...

2000-02-01

341

Effect of various coal contaminants on the performance of solid oxide fuel cells: Part II. ppm and sub-ppm level testing  

Energy Technology Data Exchange (ETDEWEB)

The poisoning effects of various trace contaminants in the coal-derived syngas stream at ppm and sub-ppm level on the performance of Ni-YSZ/YSZ/LSM solid oxide fuel cells were studied at extended duration. The thermochemical nature of impurities such as PH{sub 3}(g) and CH{sub 3}Cl(g) in presence and absence of water steam was analyzed by a high temperature mass spectrometer. Only less than half of PH{sub 3}(g) is hydrolyzed, and CH{sub 3}Cl(g) also co-exist with HCl(g). After a certain duration of exposure, 1 ppm AsH{sub 3}(g), 0.5 ppm PH{sub 3}(g), and 2.5 ppm CH{sub 3}Cl(g) all caused some degree of degradation to the power density at 750 C. Whereas 1 ppm of H{sub 2}S(g) resulted in immediate performance loss. The mechanisms of degradation are mainly divided into two categories: surface adsorption effect (for S and Cl) and bulk reaction effect (for As and P). The controversies regarding the poisoning effect and mechanism of S are also discussed with the aid of ...

2009-09-05

342

Dynamic behaviors of sulfur evolved in the gas phase from pyrolysis of six Chinese coals  

Energy Technology Data Exchange (ETDEWEB)

Dynamic behaviors of gaseous sulfur-containing compounds evolved from pyrolysis of six Chinese coals were studied in the temperature range of up to 800{sup o}C under N{sub 2} and H{sub 2}. The released amount of total sulfur-containing gases was traced by an online flame photometric detector (FPD). Simultaneously, the changes of different sulfur forms, including H{sub 2}S, SO{sub 2}, COS and CS{sub 2}, also were investigated using an online mass spectrometer (MS). FPD results show that the effect of H{sub 2} on gaseous sulfur evolved is complex, which promoted certain peak and suppresses other peaks. Based on the data from MS, it is suggested that a series of competitive reactions between active sulfur and other active matters during pyrolysis may impact on the sulfur form in gas phase. Interactions between active sulfur-containing intermediates and the coal matrix are attributed to be the main factor determining the dynamic behavior.

2006-07-01

343

Direct sampling ion trap mass spectrometry (DSITMS). Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the cost, performance, and other key characteristics of an innovative technology for determining the presence or absence, and measuring the concentration, of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in groundwater and soil, and in gaseous remediation process streams at hazardous waste sites. This new technology is Direct Sampling Ion Trap Mass Spectrometry (DSITMS). DSITMS introduces sample materials directly into an ion trap mass spectrometer by means of a very simple interface, such as a capillary restrictor or a polymer membrane. There is typically very little, if any, sample preparation and no chromatographic separation of the sample constituents. This means that the response of the instrument to the analytes or contaminants in a sample is nearly instantaneous, and that analytical methods based on DSITMS are fast. Analyses are typically completed in less than five minutes, and the analysis cost is ...

1998-12-01

344

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has been developed for the LCL. Network communication and web server ...

2008-07-21

345

Delayed-neutron energy spectra following thermal-neutron-induced fission of Pu-239  

Energy Technology Data Exchange (ETDEWEB)

Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was accomplished employing an iterative least-squares method, incorporating a constraint requiring all six-group spectra remain positive for all neutron ...

1987-01-01

346

Delayed backbending in the #pi#h _9_/_2 band of "1"8"7Ir  

International Nuclear Information System (INIS)

High-spin states of "1"8"7Ir have been populated in the "1"7"6Yb("1"5N,4n) reaction and measured with the YRAST Ball spectrometer. The #pi#h _9_/_2 rotational band has been extended beyond the first alignment crossing, which was found at rotational frequency (#Planck constant#/2#pi#)#omega# _c #approx =#0.39 MeV . Two different scenarios for describing this crossing are considered: the alignment of an h _9_/_2 proton or i _1_3_/_2 neutron pair and it is concluded that a proton band crossing is more likely. A systematic study of the rotational alignment crossings in the #pi#h _9_/_2 bands in the N=104,106,108 isotopes of _7_3Ta,_7_5Re,_7_7Ir, and _7_9Au is presented.

2003-11-01

347

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is being developed to ...

1988-10-01

348

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is housed in a massive shield ...

1992-03-16

349

Born-Oppenheimer breakdown effects and hyperfine structure in the rotational spectrum of strontium monosulfide, SrS  

Energy Technology Data Exchange (ETDEWEB)

A newly constructed Fourier transform microwave spectrometer has been used to record the pure rotational spectra of four isotopomers of SrS ({sup 88}Sr{sup 32}S, {sup 87}Sr{sup 32}S, {sup 86}Sr{sup 32}S, and {sup 88}Sr{sup 34}S) between 6 and 26 GHz. The molecules were produced by reacting laser ablated strontium with carbonyl sulfide (0.1% in argon). Pure rotational transitions in the ground, first and second vibrational states have been observed. The data set has enabled a multi-isotopomer fit. Born-Oppenheimer breakdown terms for both atoms have been determined. The {sup 87}Sr nuclear quadrupole coupling constant in {sup 87}Sr{sup 32}S has been determined for the first time.

2007-12-06

350

A gas-jet ECR ion source at TRIGA-SPEC  

International Nuclear Information System (INIS)

The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of the experiments are presented.

2010-03-08

351

A facile one-pot hydrothermal method to prepare europium-doped titania hollow phosphors and their sensitized luminescence properties  

British Library Electronic Table of Contents (United Kingdom)

Monodisperse europium-activated titania hollow phosphors had been synthesized by a facile one-pot hydrothermal method using carbon spheres as hard templates. Samples were characterized by X-ray powder diffraction, transmission electron microscopy, X-ray photoelectron spectroscopy, energy dispersive spectrometer and photoluminescence spectrum. The strongest emission intensity was observed with TiO2:Eu0.2 hollow spheres and TiO2:Eu0.2 hollow spheres calcining at 550^oC. Moreover, the strongest excitation of TiO2:Eu0.2 hollow spheres transferred from 400 to 500^oC and the effective nonradiative energy transfer from the TiO2 hollow spheres host matrix to Eu^3^+ ions crystal field states was realized due to changes of crystalline field in the environment around Eu^3^+ ions occupying Ti^4^+ site...

2010-01-01

352

A Single-Shot Method for Measuring Femtosecond Bunch Length in Linac-Based Free-Electron Lasers  

International Nuclear Information System (INIS)

There is growing interest in the generation and characterization of femtosecond and subfemtosecond pulses from linac-based free-electron lasers (FELs). In this report, following the method of Ricci and Smith (Phys. Rev. ST Accel. Beams 3, 032801 (2000)), we investigate the measurement of the longitudinal bunch profile of an ultrashort electron bunch produced by these FELs. We show that this method can be applied in a straightforward manner at x-ray FEL facilities such as the Linac Coherent Light Source by slightly adjusting the second bunch compressor followed by running the bunch on an rf zero-crossing phase of the final linac. We find that the linac wakefield strongly perturbs the measurement, and through analysis show that it can be compensated in a simple way. We demonstrate the effectiveness of this method and wakefield compensation through numerical simulations, including effects of coherent synchrotron radiation and longitudinal space charge. When used in conjunction with a ...

2010-08-26

353

Investigation of flora and fauna species of Lake Baikal by electron-probe microanalysis  

International Nuclear Information System (INIS)

Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. Measurements of ...

354

DECAY OF Ta$sup 177$ AND Lu$sup 177$ TO LEVELS IN Hf$sup 17$$sup 7$  

Science.gov (United States)

The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gamma spectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, 113.0 249.7, and ...

1961-10-15

355

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full ...

2009-05-26

356

{sup 48}Ti(n,xnpa{gamma}) reaction cross sections using spallation neutrons for E{sub n} = 1 to 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

{gamma}-ray excitation functions have been measured for the interaction of fast neutrons with {sup 48}Ti (neutron energy from 1 MeV to 250 MeV). The Los Alamos National Laboratory spallation neutron source, at the LANSCE/WNR facility, provided a ''white'' neutron beam which is produced by bombarding a natural W target with a pulsed proton beam. The prompt-reaction {gamma} rays were measured with the large-scale Compton-suppressed Ge spectrometer, GEANIE. Neutron energies were determined by the time-of-flight technique. Excitation functions were converted to partial {gamma}-ray cross sections, taking into account the dead-time correction, the target thickness, the detector efficiency, and neutron flux (monitored with an in-line fission chamber). The data analysis is presented here for neutron energies between 1 to 20 MeV. Partial {gamma}-ray cross sections for transitions in {sup 47,48}Ti, {sup 48}Sc, and {sup 45}Ca have been ...

2005-01-06

357

[Fast neutron cross section measurements]. Progress report  

Energy Technology Data Exchange (ETDEWEB)

In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first angular distribution measurements. Examples of the time-of-flight spectra that have been ...

1991-12-31

358

Utilization of a "1"3C enriched tracer for carbon flux studies in a tropical Eucalyptus exserta forest  

International Nuclear Information System (INIS)

Severe depletion of nutrients through removal of the above ground litter caused a cessation of growth of a Eucalyptus exserta forest in tropical China. Since there is no above ground input of C in this forest, microbial biomass (C_m_i_c) and soil organic C (C_o_r_g) are maintained by the below ground input only. By determining the maintenance requirement of the soil microflora, it should be possible to estimate the below ground production of this forest. To check this hypothesis the authors performed an experiment with labelled C. Since large scale production and field application of "1"4C labelled Eucalyptus litter were not feasible, 'naturally labelled' C_4 plant litter (Zea mays) was used. Maize litter has a #delta#"1"3C of -12.7 per mille as compared with a #delta#"1"3C of -30.7 per mille for Eucalyptus leaf litter. The "1"3C abundance is used to determine the amount of maize C in each of the soil layers. Investigations were made of how supplementation of the soil with litter ...

1990-10-01

359

Tunable far infrared laser spectroscopy of Van der Waals molecules in a planar supersonic jet expansion  

Energy Technology Data Exchange (ETDEWEB)

The gas phase high resolution spectroscopic study of weakly bound clusters can provide the information necessary to develop an intermolecular potential energy surface. This surface can then be used to better understand condensed phases. In this work, a tunable far infrared laser spectrometer is used to study weakly bound dimers produced in the newly developed continuous planar supersonic jet expansion apparatus. The water dimer is an extensively studied hydrogen bonded dimer. It undergoes several tunneling motions which result in splittings and perturbations of the rovibrational energy levels. A review is presented of much of the experimental and theoretical work done on water dimer, including a description of the combined fit of all the high resolution spectroscopic results by Coudert and Hougen. Also included is a discussion of the measurement of the K = 1 lower {yields} K = 2 lower band performed using the tunable far infrared laser/planar jet apparatus. The ...

1990-12-01

360

Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.  

Science.gov (United States)

Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the PRE in January 2004 was used to validate the two-band model and also applied to map ...

2010-09-01

361

Thermal stability of nanocomposite CrC/a-C:H thin films  

International Nuclear Information System (INIS)

The thermal stability of low-friction Me-C/a-C:H coatings is important for their potential applications in the tool and automotive industry. Recently we showed that CrC _x/a-C:H coatings prepared by unbalanced magnetron sputtering of a Cr target in Ar + CH_4 glow discharges exhibit a nanocomposite structure where metastable fcc CrC nanocrystals are encapsulated by an a-C:H phase. Here, we present the structural evolution of these nanocomposite CrC/a-C:H coatings during annealing. High-temperature X-ray diffraction in vacuum and differential scanning calorimetry (DSC) combined with thermo-gravimetric analysis in Ar atmosphere indicate decomposition of the formed metastable fcc CrC phase and subsequent formation of Cr_3C_2 and Cr_7C_3 and structural transformation of the a-C:H matrix phase towards higher sp"2 bonding contents at temperatures above 450 deg. C. Combined DSC and mass spectrometer analysis as well as elemental profiling after annealing in vacuum by ...

2007-05-07

362

The calibration of sub-Coulomb heavy ion proton transfer reactions  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross sections for the /sup 27/Al(/sup 16/O,/sup 15/N)/sup 28/Si, /sup 89/Y(/sup 15/N,/sup 16/O)/sup 88/Sr and /sup 89/Y(/sup 27/Al,/sup 28/Si)/sup 88/Sr reactions at energies near and below the Coulomb barrier. The first reaction required separate measurements of the transfer to elastic cross section ratio for particular charge states, the charge state distribution for /sup 27/Al and /sup 28/Si ions, and the absolute elastic scattering cross section for the /sup 27/Al + /sup 16/O system. The ratio measurement required the combined use of two relatively new scientific instruments: the momentum filter and the Bragg curve spectrometer. The latter two transfer measurements were performed using the same setup involving surface barrier detectors at backward angles. Additional elastic scattering data for the /sup 15/N + /sup 28/Si, /sup 89/Y + /sup 15/N, /sup 89/Sr + /sup 27/Al, and /sup 88/Sr + /sup 28/Si systems was collected to provide ...

1987-01-01

363

Structures and properties of fluorinated amorphous carbon films  

International Nuclear Information System (INIS)

Fluorinated amorphous carbon (a-C:F) films were deposited by radio frequency bias assisted microwave plasma electron cyclotron resonance chemical vapor deposition with tetrafluoromethane (CF_4) and acetylene (C_2H_2) as precursors. The deposition process was performed at two flow ratios R=0.90 and R=0.97, where R=CF_4/(CF_4+C_2H_2). The samples were annealed at 300 deg. C for 30 min. in a N_2 atmosphere. Both Fourier transform infrared and electron spectroscopy for chemical analyzer were used to characterize the a-C:F film chemical bond and fluorine concentration, respectively. A high resolution electron energy loss spectrometer was applied to detect the electronic structure. The higher CF_4 flow ratio (R=0.97) produced more sp"3 linear structure, and it made the a-C:F film smoother and softer. A lifetime of around 0.34 #mu#s and an energy gap of #approx#2.75 eV were observed in both the as-deposited and after annealing conditions. The short carriers lifetime in ...

2004-07-01

364

SIMS analysis of silicon on insulator structures formed by high-dose O/sup +/ implantation into silicon  

Energy Technology Data Exchange (ETDEWEB)

Silicon on insulator (SOI) structures are promising candidates for the fabrication of VLSI circuits with very high packing densities. The preparation of such structures can now be achieved by high dose implantation of reactive ion species such as oxygen to produce buried layers of SiO/sub 2/ in silicon. In this paper we report experiments to depth profile these layered structures by SIMS. SOI samples have been prepared by implanting (100) silicon wafers with 400 keV molecular oxygen ions at a dose of 1.8x10/sup 18/ O/sup +/ cm/sup -2/. During the implantation the wafers were maintained at temperatures between 325 and 600/sup 0/C, using beam heating, which achieved in situ-annealing and ensured that the top silicon layer remained single crystal. Analysis was carried out on an Atomika DIDA-II spectrometer using 10 keV Ar/sup +/ ions with a low current density of less than 1 mA cm/sup -2/. During analysis negative secondary ions were monitored which provided a high ...

1983-12-15

365

Research on laser welding of cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft  

Energy Technology Data Exchange (ETDEWEB)

Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution dendrites as the dominant and some fine and dispersed Ni{sub 3}Al {gamma}' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal due to partial ...

2008-04-03

366

Research on laser welding of cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft  

International Nuclear Information System (INIS)

Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution dendrites as the dominant and some fine and dispersed Ni_3Al #gamma#' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal due to partial dissolution and ...

2008-04-03

367

RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION  

International Nuclear Information System (INIS)

We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z #approx#> 2, this is the first time such systems have been ...

2009-04-10

368

Purification of CH{sub 3}Cl from CH{sub 3}I using cold trap with sealed 2,2,4-trimethylpentane for {delta}{sup 37}Cl measurement  

Energy Technology Data Exchange (ETDEWEB)

A cryogenic separation method of chloromethane (CH{sub 3}Cl) from methyl iodide (CH{sub 3}I) for {delta}{sup 37}Cl measurement with isotope ratio mass spectrometer is described. A cold trap with sealed 2,2,4-trimethylpentane (TMP) as the cryogen is used in this method. CH{sub 3}Cl can be separated from CH{sub 3}I at the TMP melting point (-107 deg. C) based on the difference in the vapor pressure between CH{sub 3}Cl (322.6 Pa) and CH{sub 3}I (lower than 1.3 Pa) at -107 deg. C. After two-step separation processes, the yields of CH{sub 3}Cl purified from CH{sub 3}Cl-CH{sub 3}I mixture are 96-101%, and the difference between the {delta}{sup 37}Cl{sub original} and {delta}{sup 37}Cl{sub Afterseparation} is from -0.06 to +0.06 per mille (0.01 {+-} 0.04 per mille ). These results suggest that CH{sub 3}Cl is completely separated from CH{sub 3}I with no change of {delta}{sup 37}Cl value. This method using the cold trap with sealed TMP is very safe and not harmful, because ...

2006-01-05

369

Products of the Benzene + O(3P) Reaction  

Science.gov (United States)

The gas-phase reaction of benzene with O(3P) is of considerable interest for modeling of aromatic oxidation, and also because there exist fundamental questions concerning the prominence of intersystem crossing in the reaction. While its overall rate constant has been studied extensively, there are still significant uncertainties in the product distribution. The reaction proceeds mainly through the addition of the O atom to benzene, forming an initial triplet diradical adduct, which can either dissociate to form the phenoxy radical and H atom, or undergo intersystem crossing onto a singlet surface, followed by a multiplicity of internal isomerizations, leading to several possible reaction products. In this work, we examined the product branching ratios of the reaction between benzene and O(3P) over the temperature range of 300 to 1000 K and pressure range of 1 to 10 Torr. The reactions were initiated by pulsed-laser photolysis of NO2 in the presence of benzene and helium buffer in a ...

2009-12-21

370

Ozone Layer Observations  

Science.gov (United States)

The US National Aeronautics and Space Administration (NASA) has been monitoring the ozone layer from space using optical remote sensing techniques since 1970. With concern over catalytic destruction of ozone (mid-1970s) and the development of the Antarctic ozone hole (mid-1980s), long term ozone monitoring has become the primary focus of NASA's series of ozone measuring instruments. A series of TOMS (Total Ozone Mapping Spectrometer) and SBUV (Solar Backscatter Ultraviolet) instruments has produced a nearly continuous record of global ozone from 1979 to the present. These instruments infer ozone by measuring sunlight backscattered from the atmosphere in the ultraviolet through differential absorption. These measurements have documented a 15 Dobson Unit drop in global average ozone since 1980, and the declines in ozone in the antarctic each October have been far more dramatic. Instruments that measure the ozone vertical distribution, the SBUV and SAGE (Stratospheric ...

2002-01-01

371

Magnetic excitations in R_2PdSi_3 studied by inelastic neutron scattering  

International Nuclear Information System (INIS)

R_2PdSi_3 compounds have been found to exhibit rich magnetic phenomena arising from the interplay between RKKY interaction, crystal electric field effects and geometric frustration due to the derived hexagonal AlB_2 structure. The observed crystallographic superstructure further complicates the CEF level scheme. Inelastic neutron scattering measurements on single crystals of Tm_2PdSi_3 and Er_2PdSi_3 have been performed at the cold triple axis spectrometer PANDA in FRM-II. Both compounds order antiferromagnetically at T_N=7 K and 2.1 K respectively; Er_2PdSi_3 undergoes a second phase transition at T_2=2 K. Several low lying CEF excitations (below 10 meV) were observed. The intensity of the lowest excitation show strong directional dependence (in HK0 plane for Er_2PdSi_3 and in HHL plane for Tm_2PdSi_3), from which the details of the transitional matrix could be deduced. Measurements in magnetic fields up to 13 T show Zeeman splitting of the CEF excitations. In ...

2009-03-22

372

M shell x-ray emission in Pb, Th and U due to L_3 to M sub shell transfer of vacancies  

International Nuclear Information System (INIS)

M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell x-ray emission were evaluated and it is seen that the shift of vacancies from L_3 ...

373

Infrared stimulated luminescence and phosphorescence spectra of irradiated feldspars  

International Nuclear Information System (INIS)

A new high-sensitivity wide-bandwidth 1.25-5.5 eV (225-1000 nm) spectrometer has been constructed to measure luminescence emission spectra of minerals that are of interest for optical dating. Spectra of emission resulting from 1.43 eV (IR) excitation after #gamma#-irradiation are reported for 13 cut rock feldspars and 20 feldspar separates. Also reported are phosphorescence spectra following #gamma#-irradiation, and after 1.4 eV excitation. The main differences between the infrared stimulated luminescence spectra and the phosphorescence is the almost complete absence of the violet, 3.1 eV, and yellow-green, 2.2 eV, bands in the phosphorescence, and the presence of a green emission band centred at 2.7 eV in the phosphorescence following #gamma#-irradiation (but absent in the phosphorescence following 1.4 eV excitation). The red, 1.7 eV, band is present in all the phosphorescence spectra but is not always seen during 1.4 eV excitation. A band at #approx# 1.3 eV is ...

2003-11-26

374

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed that a single window ...

375

High-precision Penning-Trap measurements of light-ion masses  

International Nuclear Information System (INIS)

The UW-Penning Trap Mass Spectrometer (PTMs) is ideally suited for high precision measurements of atomic masses throughout the periodic table upon using highly-stripped ions. However, at the present time, this device has been applied extensively to the light elements ("1H, "2H, "3H, "3He, "4He, "1"2C, "1"3C, "1"4N, "1"6O) due to their fundamental importance. Atomic masses follow immediately from a comparison with some multiply-charged carbon ion, after correcting for the lost electrons and their corresponding binding energies. For instance, the most recent C"5"+/C"6"+ comparison yielded a discrepancy of -0.30(33) ppb, limited only by the magnetic field instability for a 40-h run. The initial emphasis on hydrogen has now produced a 1-ppb value for the proton's atomic mass and similar work with deuterium has yielded a 2.5-ppb value for the neutron's atomic mass. However, the most significant result is the "3H-"3He mass difference = 18,590.1(17) eV which is determined ...

1993-04-12

376

HPLC-APCI-MS analysis of triacylglycerols (TAGs) in historical pharmaceutical ointments from the eighteenth century.  

Science.gov (United States)

The lipid fractions of residues from historical pharmaceutical ointments were analysed by reversed-phase liquid chromatography coupled with atmospheric pressure chemical ionization and mass spectrometer detection. The residues were contained in a series of historical apothecary jars, dating from the eighteenth century and conserved at the "Aboca Museum" in Sansepolcro (Arezzo, Italy) and at the pharmacy of the "Real Cartuja de Valldemossa" in Palma de Majorca (Spain). The analytical protocol was set up using a comparative study based on the evaluation of triacylglycerol (TAG) compositions in raw natural lipid materials and in laboratory-reproduced ointments. These ointments were prepared following pharmaceutical recipes reported in historical treatises and used as reference materials. The reference materials were also subjected to stress treatments in order to evaluate the modification occurring in the TAG profiles as an effect of ageing. TAGs were successfully ...

2011-06-29

377

First Light for MIRSI  

Science.gov (United States)

We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system offers the unique ability to acquire both spectra and high-resolution, multi-wavelength ...

2001-12-01

378

Experimental investigation of the KLL Auger spectrum of "8"8Sr from the EC-decay of "8"8Y  

International Nuclear Information System (INIS)

According to the calculations, intensity of the KL_1L_2("3P_0) Auger transition should drastically increase with increasing atomic number Z due to the relativistic effects. However, this behavior was experimentally proved only for very few elements. A lack of enough precise experimental data in the atomic number region Z<45 does not enable one to distinguish between relativistic and non-relativistic approaches in this region. Thus for Z=38 the KL_1L_2("3P_0/"1P_1) intensity ratio was determined with relative uncertainty of 63 % in the only measurement with external excitation. Here we present results of our investigation of the KLL Auger electron spectrum of "8"8Sr generated in the EC decay of "8"8Y (T_1_/_2= 106.6 d). Electron spectra were measured with the 11 eV instrumental resolution using a combined electrostatic spectrometer. The present value of the KL_2L_3("1D_2) absolute transition energy in Sr is higher by 7.4 eV (i.e. more than 3#sigma#) then that ...

2007-06-04

379

Excitation function of "5"9 Co (n, 2n) "5"8 Co process in the energy range 13.9-14.7 MeV  

International Nuclear Information System (INIS)

The objective of the study is to measure the neutron cross sections for the "5"9 Co (n, 2n) "5"8 Co reaction around the 14 MeV energy region. Neutron activation cross section for almost all the nuclei, mostly in the medium energy region e.g., 7 to 20 MeV are reported in literature. Neutron cross section data around 14 MeV is of immense importance for the design of D + T fusion reactors. The accuracy of the cross section data at this energy region is a requirement for correct prediction of reactor parameters e.g., tritium breeding, nuclear heating, induced activity, etc. In order to perform the experiment, the Co-sample sandwiched in Ni foils was irradiated employing the J-25 Neutron Generator at the AERE, Savar, Dhaka. After irradiation, the counting was done by the activation technique using a high resolution Hp Ge gamma ray spectrometer. The gamma ray spectra was analyzed in a Canberra series-40 Multi-channel Analyzer. Calculations for cross sections were done at ...

380

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

Energy Technology Data Exchange (ETDEWEB)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of {gamma}-FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution dendrites as the ...

2007-06-30

381

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

International Nuclear Information System (INIS)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of #gamma#-FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution dendrites as the dominant ...

2007-06-30

382

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

Science.gov (United States)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of ?-FeCr0.29Ni0.16C0.06 austenite solid solution dendrites as the dominant and very small ...

2007-06-01

383

Determination of sodium in biological samples by instrumental neutron activation analysis  

International Nuclear Information System (INIS)

Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring sodium abundances. About 2g each of samples and ...

1981-05-01

384

Decay behaviors of H{sub 2}{sup -} anions in solid parahydrogen. Effect of nuclear spins on chemical reactions  

Energy Technology Data Exchange (ETDEWEB)

Decay processes of H{sub 2}{sup -} anions in {gamma}-rays-irradiated solid parahydrogen were studied by using ESR spectrometer. The following interesting results were obtained. First, the initial amount of ortho-H{sub 2}{sup -} anions in the {gamma}-irradiated solid parahydrogen was three times as large as those of para-H{sub 2}{sup -} anions. Second, the amount of para-H{sub 2}{sup -} anions decreases faster than that of ortho-H{sub 2}{sup -} anions upon storage of the irradiated samples at 4.2 K. Third, the decay rate of H{sub 2}{sup -} anions is accelerated by the addition of D{sub 2} molecules. Forth, H{sub 2}{sup -} anions at 2.2 K decay faster than at 4.2 K. According to the parity conservation rule in a homonuclear diatomic molecule, the energy of ortho-H{sub 2}{sup -} anions at the ground state is lower than that of para-H{sub 2}{sup -} anions, whereas that of ortho-H{sub 2} molecules is higher than that of para-H{sub 2} molecules at low temperatures. The ...

1996-11-01

385

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-15

386

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are collected with a ...

2006-03-01

387

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and elemental distribution ...

2005-06-11

388

Carbon dioxide absorption of He--Ne laser radiation at 4. 2. mu. m: characteristics of self and nitrogen broadened cases  

Energy Technology Data Exchange (ETDEWEB)

A laser resonance absorption spectrometer is used to investigate the characteristics of both self and nitrogen collision broadened carbon dioxide in resonance with He--Ne laser radiation at 4.2 ..mu..m. The absorption coefficient in these broadening conditions has contributions from the R(28) to R(34) absorption lines of the ..nu../sub 3/ CO/sub 2/ spectrum. The Fletcher-Powell optimization method is used to reduce the raw absorption data and to find the best value average collision broadening coefficient and laser emission frequency for a Lorentzian line shape model of the contributing lines. Pure carbon dioxide absorption in a pressure range of from 0.0016 atm (1.25 Torr) to 0.33 atm (250 Torr) is described well by the model with an average self broadening coefficient of 0.084 +- 0.008 cm/sup -1/ atm/sup -1/ for laser frequencies located at either 2370.591 +- 0.020 cm/sup -1/ or 2371.135 +- 0.019 cm/sup -1/. Nitrogen broadened carbon dioxide in the total pressure ...

1989-03-01

389

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ns) ablation was performed in air. The ...

2010-08-15

390

CO{sub 2} bands in the 3350 - 3700 cm{sup {minus}1} spectral region: Ro-vibrational constants and absolute intensities  

Energy Technology Data Exchange (ETDEWEB)

Spectroscopic constants and absolute intensities from more than 2150 transitions belonging to 52 bands of 7 isotopic species of carbon dioxide have been determined using a multispectrum nonlinear least-squares fitting technique. The spectral data (0.01 cm{sup -1} resolution) were obtained at room temperature and low pressure (<10 Torr) using the McMath-Pierce Fourier transform spectrometer of the National Solar Observatory on Kitt Peak, Arizona. A natural sample of carbon dioxide with absorption path lengths between 24 and 385m were used in recording the spectra. The first measurements have been made of the theoretically predicted 2v{sub 2}{sup 2} 2+v{sub 3} {open_quotes}forbidden{close_quotes} band of {sup 12}CO{sub 2}. Two bands which have not been predicted so far, one belonging to {sup 13}CO{sub 2} and the other to {sup 13}C{sup 16}O{sup 18}O, have been identified. The measured line intensities obtained for each band have been analyzed to determine the ...

1995-12-31

391

Automated ARXPS goniometer/diffractometer. Final report, April 1995--March 1997  

Energy Technology Data Exchange (ETDEWEB)

This award provided for an automated computer-controlled goniometer/diffractometer/manipulator with hot and cold stages and data acquisition system that was interfaced with the high resolution Scienta ESCA-300 X-ray photoelectron spectrometer at Lehigh University. The automation allows angular dependent X-ray photoelectron spectroscopy (XPS) and ultraviolet photoelectron spectroscopy (UPS) data to be accurately and rapidly collected without the very time-consuming and labor-intensive manual method that was previously required. It also provides for automated multi-sample analyses, collecting both wide survey scans and selected binding energy range analyses, with complete computer control and data storage. This allows 24 hour data collection without requiring the continuous presence of operators. The overall result is a greater productivity for the XPS laboratory, approximately doubling the output of the laboratory. While the automated computer-controlled ...

1998-07-01

392

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved x-ray-emitting zones for all the anodes were captured by a pinhole-based x-ray imaging camera and the images were scanned for different gray levels by using a MATLAB computing ...

2006-01-01

393

Analysis of Elements in The Baltic Sea Sediment by Using Gamma Spectrometry  

International Nuclear Information System (INIS)

We have done analysis of elements in the Baltic sea sediment by using gamma spectrometry in neutron activation analysis Goal of the analysis is to determine the rate of morsel elements which is contained in the Baltic sea sediment. Sample of the Baltic sea Sediment (IAEA-SED-1), Standard of Reference Material (SRM) 1646 Estuarine Sediment and Standard Ce, Fe, Sc, and Co are put into vial of capsule rabbit, then irradiated together for 30 minutes in rabbit facility Multi Purpose Reactor at power of 25 MW and then cooled for one week. Next sample, standard, and SRM which have irradiated, each is cut for 30 minutes using gamma spectrometer. Result of analysis of rate of elements Ce, Fe, Sc and Co in the baltic sea sediment successively equal to 141.20 ppm, 5.91 %, 14.88 ppm, and 19.59 ppm. Result of analysis in SRM Estuarine sediment successively equal to 96.60 ppm, 3.21 %, 10.25 ppm, and 9.63 ppm. Result of this analysis if compared to the value contained in SRM ...

2007-04-01

394

An experimental investigation of H{sub 2} emissions of a 2004 heavy-duty diesel engine supplemented with H{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen (H{sub 2}) emissions characteristics of H{sub 2}-diesel dual fuel engine were measured using a 2004 turbocharged heavy-duty diesel engine with H{sub 2} supplemented into the intake air. The emissions of H{sub 2} were measured using an Electron Pulse Ionization (EPI) Mass Spectrometer (MS). The effect of the amount of H{sub 2} added, the engine load, and diesel fuel flow rates on the emissions of H{sub 2} and its combustion efficiency in the engine were investigated. The addition of H{sub 2} under high load operation was notable for its ability to obtain high H{sub 2} combustion efficiency and improve brake thermal efficiency. However, the addition of H{sub 2} at low load resulted in high emissions of H{sub 2} due to the failure to initiate and support a sufficiently vigorous flame for the complete combustion of H{sub 2} present outside the diesel spray plume. The maximum H{sub 2} emissions of 1.4% (volume in dry exhaust gas) were observed with the addition ...

2010-10-15

395

A REAL-TIME COAL CONTENT/ORE GRADE (C2OC) SENSOR  

Energy Technology Data Exchange (ETDEWEB)

This is the final report of a three year DOE funded project titled ''A real-time coal content/ore grade (C{sub 2}OG) sensor''. The sensor, which is based on hyperspectral imaging technology, was designed to give a machine vision assay of ore or coal. Sensors were designed and built at Resonon, Inc., and then deployed at the Stillwater Mining Company core room in southcentral Montana for analyzing platinum/palladium ore and at the Montana Tech Spectroscopy Lab for analyzing coal and other materials. The Stillwater sensor imaged 91' of core and analyzed this data for surface sulfides which are considered to be pathfinder minerals for platinum/palladium at this mine. Our results indicate that the sensor could deliver a relative ore grade provided tool markings and iron oxidation were kept to a minimum. Coal, talc, and titanium sponge samples were also imaged and analyzed for content and grade with promising results. This research has led ...

2005-04-01

396

Preliminary study of the {alpha} ratio measurement, ratio of the neutron capture cross section to the fission one for {sup 233}U, on the PEREN platform. Development and study of the experimental setup; Etude preliminaire de la mesure du rapport {alpha}, rapport de la section efficace moyenne de capture sur celle de fission de l'{sup 233}U, sur la plateforme PEREN. Developpement et etude du dispositif experimental  

Energy Technology Data Exchange (ETDEWEB)

Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...

2007-12-15

397

Distribution of naturally occurring radionuclides activity concentration in East Malaysian marine sediment  

Energy Technology Data Exchange (ETDEWEB)

Studies of naturally occurring radioactive materials (NORM) distribution of {sup 226}Ra, {sup 228}Ra and {sup 40}K in East Malaysia were carried out as part of a marine coastal environment project. The results of measurements will serve as baseline data and background reference level for Malaysia coastlines. Sediments from 21 coastal locations and 10 near shore locations were collected for analyses. The samples were dried, finely ground, sealed in a container and stored for a minimum of 30 days to establish secular equilibrium between {sup 226}Ra and {sup 228}Ra and their respective radioactive progenies. They were counted using a high-purity germanium (HPGe) spectrometer covering the respective progeny energy peak. For {sup 40}K, the presence of this was measured directly via its 1460 keV energy peak. The concentration of {sup 226}Ra, {sup 228}Ra and {sup 40}K in samples obtained from coastal Sarawak ranged between 23 and 41 (mean 30{+-}2) Bq/kg, 27 and 45 (mean ...

2009-04-15

398

Delayed neutron energy spectra following fast fission of "2"3"8U  

International Nuclear Information System (INIS)

Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 keV and Bicron BC 501 liquid ...

399

Coupled effects of the precipitation of secondary species on the mechanical behaviour and chemical degradation of concretes; Les effets couples de la precipitation d'especes secondaires sur le comportement mecanique et la degradation chimique des betons  

Energy Technology Data Exchange (ETDEWEB)

Sulfate attack of cement-based materials remains an important problem for the durability assessment of containers and disposal engineering barriers dedicated to the long-term storage of radioactive wastes since underground water which may reach these elements contains small quantities of sulfates (7-31 mmol/1). This work contributes to the study of sulfate-induced damage mechanisms, to their understanding and modelling. The experimental phases of this study aimed at the understanding of the different physico-chemical phenomena involved during an external sulfate attack at following their evolution and their impact on the transport and mechanical properties of the material. Leaching experiments in pure water and in a solution of sodium sulfate (with a sulfate content of 15 mmol/1), have been performed simultaneously on OPC paste (w/c 0,4)in order to allow a comparison of test results. The frequent analysis of the leachant has shown a consumption of sulfate ions by the matrix, ...

2002-06-01

400

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...

401

Application of photogrammetry, remote sensing and GIS in the environmental monitoring of the Deutsche Steinkohle AG; Einsatz von Photogrammetrie, Fernerkundung und GIS im Umweltmonitoring der Deutschen Steinkohle AG  

Energy Technology Data Exchange (ETDEWEB)

Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: the use of the ...

2006-03-15

402

Aerosol composition, chemistry, and source characterization during the 2008 VOCALS Experiment  

Energy Technology Data Exchange (ETDEWEB)

Chemical composition of fine aerosol particles over the northern Chilean coastal waters was determined onboard the U.S. DOE G-1 aircraft during the VOCALS (VAMOS Ocean-Cloud-Atmosphere-Land Study) field campaign between October 16 and November 15, 2008. SO42-, NO3-, NH4+, and total organics (Org) were determined using an Aerodyne Aerosol Mass Spectrometer, and SO42-, NO3-, NH4+, Na+, Cl-, CH3SO3-, Mg2+, Ca2+, and K+ were determined using a particle-into-liquid sampler-ion chromatography technique. The results show the marine boundary layer (MBL) aerosol mass was dominated by non- sea-salt SO42- followed by Na+, Cl-, Org, NO3-, and NH4+, in decreasing importance; CH3SO3-, Ca2+, and K+ rarely exceeded their respective limits of detection. The SO42- aerosols were strongly acidic as the equivalent NH4+ to SO42- ratio was only ~0.25 on average. NaCl particles, presumably of sea-salt origin, showed chloride deficits but retained Cl- typically more than half the ...

2010-03-15

403

Activities and activity ratios of U and Ra radioisotopes in drinking wells, springs and tap water samples in Morocco  

International Nuclear Information System (INIS)

Radiochemical results ("2"3"4U, "2"3"8U, "2"2"6Ra and "2"2"8Ra activities; "2"3"4U/"2"3"8U, "2"2"8Ra/"2"2"6Ra and "2"2"6Ra/"2"3"8U activity ratios) are reported for 31 drinking water samples collected from 8 wells, 12 hot mineral springs, 5 cold springs, and 6 tap water samples. Activities of the Ra isotopes were measured by gamma spectrometry using a low background and high efficiency well type germanium detector. The U isotopes were counted in an alpha spectrometer. The results show that "2"3"8U activity varies between 4.46 and about 308 mBq l"-"1 in wells, 0.59 and 17.88 mBq l"-"1 in hot springs, 2.19 and 3.21 mBq l"-"1 in cold springs, and between 2.5 and 15.70 mBq l"-"1 in tap water samples. "2"3"4U/"2"3"8U activity ratio is generally higher than 1 which is the equilibrium activity ratio value in closed systems. It varies in the ranges 0.79-2.11 in wells, 0.97-7.39 in hot springs, 2.53-8.30 in cold springs, and 1.14-3.35 in tap water. Unlike well waters, ...

404

/sup 18/O isotope effect in carbon-13 nuclear magnetic resonance spectroscopy. Part 8. Oxygen exchange of 2,4,6-trimethylpyrylium cation  

Energy Technology Data Exchange (ETDEWEB)

The rate of the oxygen-exchange reaction in an aqueous solution of a heterocyclic oxygen compound, 2,4,6-trimethylpyrylium perchlorate, was quantitated. The /sup 18/O isotope effect in /sup 13/C NMR spectroscopy affords a direct, continuous, and relatively simple analysis of the reaction and was used to obtain data on the incorporation of /sup 18/O from solvent H/sub 2//sup 18/O into the pyrylium salt. Due to the low solubility of this salt in aqueous solutions, 2,4,6-trimethyl(2-/sup 13/C)pyrylium perchlorate and 2,4,6-trimethyl(2,6-/sup 13/C/sub 2/)pyrylium perchlorate were synthesized to facilitate the acquisition of the data on an NTC-200 spectrometer operating at 50.31 MHz. Upon incorporation of /sup 18/O into the pyrylium salt, the /sup 13/C NMR signal of the directly bonded carbon atom is shifted upfield 0.038 ppm. A /sup 13/C isotope effect is also detected in the doubly /sup 13/C-enriched pyrylium salt where the /sup 13/C NMR signal for /sup 13/C-O-/sup ...

1984-12-12

405

Temperature-dependent properties of semiconductor quantum dots in coherent regime; Temperaturabhaengige Eigenschaften einzelner Halbleiter-Quantenpunkte im Kohaerenten Regime  

Energy Technology Data Exchange (ETDEWEB)

Recently, the public has become aware of keywords like ''Quantum computer'' or ''Quantum cryptography''. Regarding their potential application in solid state based quantum information processing and their overall benefit in fundamental research quantum dots have gained more and more public interest. In this context, quantum dots are often referred to as ''artificial atoms'', a term subsuming their physical properties quite nicely and emphasizing the huge potential for further investigations. The basic mechanism to be considered is the theoretical model of a two-level system. A quantum dot itself represents this kind of system quite nicely, provided that only the presence or absence of a single exciton in the ground state of that structure is regarded. This concept can also be expanded to the presence of two excitons (bi-exciton). Transitions between the relevant levels can be ...

2009-10-15

406

Structure, morphology and hydrogen storage properties of composites prepared by ball milling Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} with La-Mg-based alloy  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen storage alloy composites La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5}(x=0,5,10) were prepared by ball milling method. Their structures, morphologies and the hydrogen storage characteristics were intensively studied in the present work. It was found that the bulk of composites maintained the hexagonal C14 Laves phase structure after ball milling with additional La-Mg-based alloy for two hours. Scanning electron microscopy (SEM) observations revealed that the average size of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub 0.3}V{sub 0.3} and La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} particles were reduced to several hundred nanometers after ball milling process. Energy dispersive X-ray spectrometer (EDS) patterns of the composites showed that the La{sub 0.7}Mg{sub 0.25}Zr{sub 0.05}(Ni{sub 0.85}Co{sub 0.15}){sub 3.5} phase was uniformly distributed on the surface of Ti{sub 0.9}Zr{sub 0.2}Mn{sub 1.5}Cr{sub ...

2007-10-15

407

Review of JT-60U experimental results from February to October, 1999  

International Nuclear Information System (INIS)

In 1999, the plasma parameters of reversed shear (RS) plasmas had been extended in 1) DT-equivalent fusion power gain Q_D_T"e"q - 0.5 (n_D(0)#tau#_ET_i(0) - 4x10"2"0 m"-"3#centre dot#keV#centre dot#s) for 0.8 s and 2) full non-inductive current drive with 80% of the bootstrap current fraction. Physics of the internal transport barriers (ITBs) in RS plasmas, including the energy transport and the formation of ITB, were extensively studied. A nearly full current drive (92% non-inductively) was obtained with negative ion based neutral beam (NNB) injection (360 keV, 3.4 MW) in a high #beta#_p H-mode plasma (I_p=1.5 MA, B_T=3.7 T, q_9_5=4.2) with high plasma performance (#beta#_N=2.4 and H_8_9=2.56). Rise in the central electron temperature (T_e - 9 keV) resulted in the current drive efficiency #eta#_C_D of NNB reached 1.3x10"1"9 A/W/m"2, the highest for the neutral beam current drive. As for the H-mode plasmas, decrease in the pedestal ion temperature due to strong gas was found cause ...

1994-06-01

408

Radioactive targets for neutron-induced cross section measurements  

Science.gov (United States)

Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of DANCE, combined with the high TOF-neutron ...

2004-01-01

409

Potential of sub-ablative pulsed CO{sub 2} laser irradiation on inhibition of artificial caries-like lesion progress in bovine dental enamel; Potencial de inibicao da progressao da carie artificial por irradiacao sub-ablativa com laser de CO{sub 2} pulsado em esmalte dental bovino  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to investigate whether sub-ablative pulsed C0{sub 2} laser (1 0,6 {mu}m) irradiation is capable of reducing the susceptibility of the dental enamel to demineralization, and thus achieving a potential caries-protective effect. The crowns of 51 bovine front teeth, embedded in acrylic resin and polished until exposure of flat enamel surface, were used. The samples were cut in cubes of 10x10 mm, and totally coated with acid-resistant nail varnish, except for an enamel exposed window of 16 mm square. Three groups (n=17) were obtained: control group (CG) not irradiated; group laser A (LA) and group laser B (LB) where the samples were irradiated. The conditions were 60 mJ, 100 Hz, 0,3 J/cm{sup 2} for LA and 135 mJ, 10 Hz, 0,7 J/cm{sup 2} for LB. Two samples of each group were submitted to SEM analysis and fifteen to demineralization in 3 ml acetate buffer solution (0,1 mol/L) with pH 4,5 for 24h at 37 deg C, with regular agitation. After the specimens were removed ...

2005-07-01