This article gives an account of the recent development of light water reactors new concepts in the world. Different projects are being studied. The CE80+ from Combustion Engineering (CE) is a 1350 MWe-PWR-type reactor whose primary circuit is confined in a spherical metallic containment. This reactor was certified by NRC (national regulatory commission) in mid-1996. The APWR (advanced pressurized water reactor) is developed by MHI (Mitsubishi heavy industries) in a collaboration with Westinghouse, this PWR-type reactor fitted with 4 loops derived from the SP90 model that was developed by Westinghouse during the eighties. 2 units of ABWR (advanced boiling water reactor) were commissioned in Japan in 1996 and 1997, ABWR was certified by NRC in mid-1996. The BWR90+ is developed by ABB-atom (Sweden) and it represents a cautious advanced version of the BWR75. Passive reactors are reactors that rely only on potential energy (compressed gas, gravitational flow or electric batteries) to feed ...
This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)
This document exposes the results of the fourth evaluation report of the working group II of the inter government experts group on the climatic change. This evaluation presents the today scientific understanding of the climatic change impacts on the humans and their adaptation ability and vulnerability. It is based on the GIEC evaluations and new knowledge added since the third evaluation report. (A.L.B.)
The lateral bearing device is made of 7 lateral supports, each positioned to allow the displacement of the steam generator due to thermal or seismic effects. Each support includes a buffer plate that can be positioned on the steam generator using a position control assembly. This control assembly consists of a screw jack arrangement where the nut is fastened via an energy absorbing layer to a footplate that is fixed to the concrete wall of the steam generator enclosure. 4 figs.
We have studied freshly prepared lysozyme solutions in heavy water for two NaCl concentrations as a function of temperature. Lysozyme solubilities in this solvent are determined by static light scattering. By small angle neutron scattering, we evidence that interactions between lysozyme molecules are characterized by a second virial coefficient A{sub 2} whether the solution is under-saturated or supersaturated. From the variation of A{sub 2} as a function of temperature we have evaluated the enthalpy corresponding to the interaction between lysozyme molecules. We show that the interactions between protein molecules are higher in heavy water than in light water. (authors). 13 refs., 3 figs.
Since mid-March the Commission on Water Management, with the assistance of the appropriate ministries, visited all regions of the province in order to acquaint themselves first hand with regional water management problems. During the month of June, the Commission also organized a series of ten workshops, attended by a limited number of experts, to explore in depth certain specific questions in the area of water management. During these public sessions the Commission hoped to discuss specifically the specific questions relating to water management problems of First Nations communities, bearing in mind the essential nature of water in maintaining traditional activities. The workshop took place on the Montanard reserve of Mashteuiatsh (Pointe-Bleu). The morning session was devoted to presentations by invited experts, followed by an exchange of views between the experts and the Commissioners, with opportunity for participants to address question to the experts. This document was compiled ...
The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation participates in radiation protection and allows to make sure that the G.I.P. operator respects the required regulatory thresholds. ...
Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma radiation is observed. About the neutrons monitoring, the measures made during the ...
Une enfant drepanocytaire homozygote SS de 14 ans (sans deficit en G6PD), non transfusee anterieurement, a une cholecystectomie pour lithiase decouverte a un bilan systematique. L'intervention est encadree de 2 transfusions de concentres erythrocytaires (CGR) phenotypes ABO Rh Kell, compatibilises. Quinze jours apres, elle presente une hemolyse aigue associant fievre, ictere, insuffisance renale tubulaire, hemoglobinurie et anemie profonde (Hb 3,6 g/dL). Les RAI deviennent positives avec, entre autres, un auto anticorps anti D suspecte, le test de Coombs direct est positif de type mixte. L'enfant n'est pas retransfusee, mais recoit 1 mg/kg/j de corticoides IV pendant 10 jours. L'hemoglobine retrouve sa valeur de base (9 g/dL) apres 15 jours. Un antigene RH1(D) partiel de type DAR est ulter...
Acid mine drainage represents one of the most important environmental problem facing the mining industry. If the tailings contain sulphur, acid mine drainage will be generated as soon as the tailings are exposed to oxygen. In this paper, the authors discussed a technique for the storage of acid mine drainage generating tailings that delays and even eliminates the occurrence. It was suggested that tailings should be piled by incorporating, at regular intervals, compacted waste rock. Thermal convection and diffusion will prevent oxygen from reaching the tailings, and limit water circulation. The modelling of transfer processes (heat, water, oxygen) in a well known tailings dump, the Doyon Mine, was performed, and the results compared to the modelling where compacted waste rock had been incorporated at regular intervals. The results indicated that by remaining saturated, the layers acted as capillary barriers preventing oxygen from reaching the tailings, therefore reducing significantly ...
In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided under the Public Health Code (Code de sante publique). Proper permits and ...
This research has two main goals. First, we wanted to introduce optimization tools in the diffusion code DONJON, mostly for fuel management. The second objective is more practical. The optimization capabilities are applied to the fuel management problem for different CANDU reactors at refueling equilibrium state. Two kinds of approaches are considered and implemented in this study to solve optimization problems in the code DONJON. The first methods are based on gradients and on the quasi-linear mathematical programming. The method initially developed in the code OPTEX is implemented as a reference approach for the gradient based methods. However, this approach has a major drawback. Indeed, the starting point has to be a feasible point. Then, several approaches have been developed to be more general and not limited by the initial point choice. Among the different methods we developed, two were found to be very efficient: the multi-step method and the mixte method. The second kind of ...