WorldWideScience
1

Ear to the ground  

CERN Multimedia

Ear to the ground

1983-01-01

4

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired ...

2003-03-01

5

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

6

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

9

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas  

International Nuclear Information System (INIS)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...

2003-03-01

10

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

11

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle; CT und MRT erworbener Veraenderungen des Innenohrs und Kleinhirnbrueckenwinkels  

Energy Technology Data Exchange (ETDEWEB)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired ...

2003-03-01

12

The contribution of ear photosynthesis to grain filling in bread wheat (Triticum aestivum L.)  

British Library Electronic Table of Contents (United Kingdom)

The contribution of ear photosynthesis to grain filling in wheat (Triticum aestivum L.) is not well known. The main objective of this work was to evaluate this contribution through three different experimental approaches: (1) ear photosynthesis was reduced by removing awns or shading the ears (in combination with a defoliation treatment), (2) grain weight per ear was compared in an 'all shaded' crop versus plants where only the vegetative parts were shaded ('ear emerging'), and (3) ear photosynthesis was reduced with DCMU (3-(3,4-dichlorophenyl)-1,1-dimethylurea), a specific inhibitor of photosystem II. In field experiments in La Plata (Argentina), cultivars Klein Escudo and BioINTA 3000 were subjected to awn removal and ear shading treatments, with or without severe defoliation, and to 'a...

2010-01-01

13

Middle ear pressure variations during anesthesia  

UK PubMed Central (United Kingdom)

SUMMARYThe aim of this study was to determine middle ear pressure changes during the operation performed under anaesthesia induced by isoflurane or desflurane. This was a prospective,...Full Text Available

2010-12-01

14

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

15

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

17

Evaluation of Peripheral Atherosclerosis: A Comparative Analysis of Angiography and Intravascular Ultrasound  

UK PubMed Central (United Kingdom)

ObjectiveAngiography remains a critical component for diagnostic imaging and therapeutic intervention in peripheral arterial disease (PAD). The goal of this study...Full Text Available

2010-04-01

18

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences  

International Nuclear Information System (INIS)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager ('Vision', Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic ...

19

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

20

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

21

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

22

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

23

Diagnostic imaging of the acutely injured patient  

Energy Technology Data Exchange (ETDEWEB)

This book provides an analysis of pathophysiologic concepts of trauma and reviews the effectiveness of the available imaging modalities in acute trauma of various organ system. Topics covered are chest injuries; abdominal trauma; fractures of long bones; the foot and ankle; the knee; hand and wrist; the elbow; the shoulder; the pelvis hips; the spine; the skull and facial trauma and the clinical assessment of multiple injuries patients. Comparative evaluation of diagnostic techniques of radiography is discussed. Normal anatomy and bone fractures along with soft-tissue injuries are described.

1985-01-01

24

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

25

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

26

Clinical magnetic resonance imaging with nuclear medicine correlation  

Energy Technology Data Exchange (ETDEWEB)

The current role of magnetic resonance imaging (MRI) in different organ systems is discussed and compared to nuclear medicine and to other available clinical diagnostic modalities. The value of optimizing radiofrequency pulse sequence selection to provide additional tissue characterization is also described. The results of nuclear medicine and MRI studies in 56 patients are compared to evaluate the clinical diagnostic contribution of each imaging modality for various pathological processes. In addition, the state-of-the-art MRI systems and future development in MRI technology with its potential contribution is defined.

1985-08-01

27

Focal lesions in external auditory canal: computed tomography images  

International Nuclear Information System (INIS)

To analyze and review the most common focal lesions of the external auditory canal (EAC), describing the computed tomography (CT) findings. The CT images of EAC were reviewed in a series of 167 patients. Abnormal findings were recorded in 13 cases. The CT images were correlated with otoscopic and/or intraoperative findings. There were four cases of osteoma (one located outside the EAC); all of which were treated surgically, as was the one case of exostosis. Six patients presented debris in EAC, coinciding with clinical evidence of external otitis. There were two cholesteatomas derived from EAC, one of them secondary to survery to treat osteoma. On patient was diagnosed as having a basal cell carcinoma of the ear, extending to EAC, but refused to undergo surgery. Five patients presented small triangular laminae of dense bone arising from the upper wall of the EAC which were defined as abnormal variants of the fusion of the ...

28

Reduction of diagnostic expense in space-occupying processes of the pancreas by fine-needle biopsy under computerized tomography (CT)  

International Nuclear Information System (INIS)

Comparative analysis of diagnostic accuracy (dignity determination) in CT-guided fine-needle biopsy (141 patients), CT (141), ultrasonography (89), angiography (50), and cholegraphy (ERCP, 55), was carried out in suspected space-occupying lesions of the pancreas. With accuracy of 86%, sensitivity of 37% and specificity of 92% fine-needle biopsy was superior to imaging procedures. Additional comparison of the results concerning the patients and Roc curves confirm the statements. For reduction of the number of imaging investigations a diagnostic algorithm is proposed, that starts with diagnostic CT and subsequent fine-needle biopsy controlled by CT. This would result in a more adequate use of angiography and ERCP and in the elimination of ultrasonography. (author).

29

Diagnostic imaging in pregraduate integrated curricula; Radiologie in einem praegraduellen problembasiert-integrierten Medizincurriculum  

Energy Technology Data Exchange (ETDEWEB)

Pregraduate medical curricula are currently undergoing a reform process that is moving away from a traditional discipline-related structure and towards problem-based integrated forms of teaching. Imaging sciences, with their inherently technical advances, are specifically influenced by the effects of paradigm shifts in medical education. The teaching of diagnostic radiology should be based on the definition of three core competencies: in vivo visualization of normal and abnormal morphology and function, diagnostic reasoning, and interventional treatment. On the basis of these goals, adequate teaching methods and e-learning tools should be implemented by focusing on case-based teaching. Teaching materials used in the fields of normal anatomy, pathology, and clinical diagnosis may help diagnostic radiology to play a central role in modern pregraduate curricula. (orig.)

2007-11-15

30

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. ...

2003-03-01

31

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

32

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was ...

1989-02-01

33

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was ...

1989-01-01

34

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

35

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

Energy Technology Data Exchange (ETDEWEB)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar accuracy than standard methods. We believe that a more general approach needs to be ...

2006-07-01

36

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

International Nuclear Information System (INIS)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar accuracy than standard methods. We believe that a more general approach needs to be ...

37

Improvement of spatial resolution in the longitudinal direction for isotropic imaging in helical CT  

Energy Technology Data Exchange (ETDEWEB)

Experiments were conducted to confirm the isotropic spatial resolution of multislice CT with a 0.5 mm slice thickness. Isotropic spatial resolution means that the spatial resolution in the transaxial plane (X-Y plane) and that in the longitudinal direction (Z direction) are equivalent. To obtain point spread function (PSF) values in the X-Y-Z directions, three-dimensional voxel data were obtained by helical scanning of a bead phantom. The modulation transfer function (MTF) values were then obtained by three-dimensional Fourier transform of the PSF. Evaluation of the spatial resolution in the X-Y-Z directions by the MTF values showed that the spatial resolution in the Z direction does not depend on the reconstruction kernel used. It was also found that the spatial resolution in the Z direction, as compared with that in the X-Y plane, is superior with the standard kernel for the abdomen and is inferior with the high-definition kernel for the ears/bones. By performing ...

2007-02-07

38

High Angular Resolution Imaging Spectroscopy of the Galactic Ultra-Compact HII Region K3-50A  

CERN Document Server

Gemini North adaptive optics imaging spectroscopy is presented for the Galactic ultra-compact HII (UCHII) region K3-50A. Data were obtained in the K-band using the Near-infrared Integral Field Spectrograph (NIFS) behind the facility adaptive optics module ALTAIR in natural guide star mode. The NIFS data cube reveals a complex spatial morphology across the 0.1 pc scale of the 3'' UCHII region. Comparison of the nebular emission to Cloudy ionization models shows that the central source must have an effective temperature between about 37000 K and 45000 K with preferred values near 40000 K. Evidence is presented for sharp density variations in the nebula which are interpreted as a clearing of material nearest the central source. High excitation lines of FeIII and SeIV show that the ionization of the nebula clearly changes with distance from the central source. A double lobed kinematic signature (+/- 25 kms) is evident in the Br gamma line map which may be related to ...

2009-01-01

39

Stereocomplexed PLA-PEG Nanoparticles with Dual-Emissive Boron Dyes for Tumor Accumulation  

UK PubMed Central (United Kingdom)

Responsive biomaterials play important roles in imaging, diagnostics, and therapeutics. Polymeric nanoparticles (NPs) containing hydrophobic and hydrophilic segments are one class of biomaterial...Full Text Available

2010-09-28

40

Cystic neoplasms of the pancreas: A diagnostic challenge  

UK PubMed Central (United Kingdom)

Cystic neoplasms of the pancreas are increasingly recognized due to the expanding use and improved sensitivity of cross-sectional abdominal imaging. Major advances in the last decade have led to an...Full Text Available

2009-01-07

41

Efficient application of medical imaging methods. Graded diagnostics for surgical and internal medical problems. Rationeller Einsatz bildgebender Verfahren. Gestufte Diagnostik bei chirurgischen und internistischen Krankheitsbildern  

Energy Technology Data Exchange (ETDEWEB)

The book is intended as a source of information for general practioners and for medical students doing their practical training. Efficient application of imaging methods is explained with great emphasis on practical aspects, concentrating on typical tasks to be solved for adult patients with internal disease or surgical problems. The material is arranged by various organic systems of the body. Graded diagnostics for a stepwise approach to the final diagnosis is the concept described, and is shown to be of advantage to the patient and in terms of cost and time.

1985-01-01

42

Hearing loss in Turner syndrome  

British Library Electronic Table of Contents (United Kingdom)

ObjectiveTo address the characteristics of hearing loss in patients with Turner syndrome (TS), we evaluated hearing levels of patients with TS and analyzed causative factors.Study designThirty-three patients with TS (8 to 40 years of age) were studied through the use of audiological measurements, and causative factors were explored.ResultsTwenty cases (35 of 66 ears tested) showed high-frequency (8 kHz) sensory neural hearing loss (HFQ-SNHL). Fifteen cases (26 ears) and 15 cases (24 ears) of the impaired 20 cases were unresponsive to distortion-product otoacoustic emissions and transient-evoked otoacoustic emissions, respectively. HFQ-SNHL showed little relation to the history of middle ear infection and puberty, although middle ear infections were seen in 11 of the 20 cases. The hearing t...

2006-01-01

43

Computed tomography of middle ear cholesteatomas without tympanic membrane perforation  

International Nuclear Information System (INIS)

The growth of a middle ear cholesteatoma behind a normal tympanic membrane is a rate though possible event. In such cases, CT may provide useful information for diagnosis. The results are presented of a CT study carried out on 14 patients affected with unilateral conductive hearing loss and with normal tympanic membrane. CT allowed the diagnosis of meddle ear cholesteatoma to be made in all cases. All patients were treated with surgery: 8 of them underwent tympanoplasty and 6 explorative tympanotomy. While the diagnosis of cholesteatoma was confirmed in 13 patients, in 1 case tympanosclerosis was diagnosed. CT diagnosis of middle ear cholesteatoma is based on the demonstration of a low-density soft-tissue mass, in association with bone erosion or ossicular dislocation. The author emphasizes the difficulty of a CT diagnosis of cholesteatoma in the patients with middle ear soft-tissue masses in the ...

1991-01-01

44

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT ...

1989-08-01

45

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT ...

1989-01-01

46

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true ...

47

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...

48

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...

1987-12-01

49

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...

1987-01-01

50

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and ...

2007-05-07

51

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were ...

1991-12-01

52

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and ...

1991-01-01

53

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

54

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

55

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

56

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

57

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

58

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

59

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with ...

60

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

Energy Technology Data Exchange (ETDEWEB)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, ...

2000-07-01

61

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

International Nuclear Information System (INIS)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, ...

1999-06-13

62

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

63

Confocal Imaging of Biological Tissues Using Second Harmonic Generation  

Energy Technology Data Exchange (ETDEWEB)

A confocal microscopy imaging system was devised to selectively detect Second harmonic signals generated by biological tissues. Several types of biological tissues were examined using this imaging system, including human teeth, bovine blood vessels, and chicken skin. All these tissues generated strong second harmonic signals. There is considerable evidence that the source of these signals in tissue is collagen. Collagen, the predominant component of most tissues, is known to have second order nonlinear susceptibility. This technique may have diagnostic usefulness in pathophysiological conditions characterized by changes in collagen structure including malignant transformation of nevi, progression of diabetic complications, and abnormalities in wound healing.

2000-03-06

64

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

65

Addition of methyl cellulose enema to double-contrast barium imaging of sigmoid diverticulosis  

Energy Technology Data Exchange (ETDEWEB)

Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).

1997-01-01

66

Variations of endonasal anatomy: relevance for the endoscopic endonasal transsphenoidal approach  

UK PubMed Central (United Kingdom)

BackgroundThe endoscopic endonasal transsphenoidal approach (EETA) to the pituitary is performed by ear, nose, and throat (ENT) surgeons in collaboration with neurosurgeons but also...Full Text Available

2010-06-01

67

Evaluation of Meal, Ready-to-Ear VIII at Market Square 2  

Science.gov (United States)

... Ready-to-Eat (MRE) VIII operational ration was evaluated at a field training exercise (Market Square II) with troops of the 82nd Airborne Division. ...

1988-09-01

68

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

69

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating ...

2003-03-15

70

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating ...

2003-03-01

71

MR imaging and MR cholangiopancreatography in the preoperative evaluation of hilar cholangiocarcinoma: correlation with surgical and pathologic findings  

International Nuclear Information System (INIS)

The primary aim was to evaluate delayed contrast-enhanced MRI in depicting perineural spread of hilar cholangiocarcinoma (CCC) and consequently to determine the capability of MRI/MRCP for staging CCC. Fifteen patients that underwent MRI/MRCP and surgical treatment were retrospectively included. Two radiologists evaluated MR images to assess delayed periductal enhancement, extent of bile duct stenosis, liver parenchymal and vascular involvement and presence of liver atrophy. An agreement between delayed enhancement of the bile duct walls and perineural neoplastic spread showed a very good correlation factor (0.93). The overall accuracy in detecting biliary neoplastic invasion was higher for delayed T1-weighted images (93.3%) than for the MRCP images (80%), and T1-delayed image increased the MR accuracy in assessing the neoplastic resectability (p < 0.05). MRI correctly predicted vascular involvement ...

2008-10-01

72

Image-guided pleural biopsy: diagnostic yield and complications  

International Nuclear Information System (INIS)

Background: Pleural biopsy and cytology are standard procedures for the investigation of pleural disease. Recent medical literature has suggested that image-guided pleural biopsy shows improved sensitivity for the diagnosis of pleural malignancy, when compared with the more commonly performed reverse bevel needle biopsy such as Abrams' needle. In our centre there has been an increasing trend towards performing image-guided pleural biopsies, and to our knowledge there is no large published series documenting the complication rate and diagnostic yield. Methods: The radiology and pathology databases were searched for all image-guided [computed tomography (CT) and ultrasound (US)] pleural biopsies from January 2001 to December 2004. All imaging and histology were reviewed, and final diagnostic information about patients was obtained from the respiratory ...

2006-08-01

73

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images ...

2007-07-01

74

Designing engineering upgradability into magnetic resonance imagers: Impact on future costs  

Energy Technology Data Exchange (ETDEWEB)

MRI is a powerful diagnostic modality of expanding availability. Equipment and installation amount to nearly $2M per site. An important component of diagnostic efficacy is not just equipment costs but also replacement costs, which for x-ray CT amount to 14-20% of the purchase cost per year; and in the early years of that technology reached 30-50%. The authors show how design choices made during the RandD stages of MRI development have allowed them to improve system performance parameters such as data reconstruction, archiving and display speeds, computational capabilities, operator interfaces, imaging sequence flexibility and signal-to-noise levels. Over the last four years these improvements have been made at a retrofit cost well below the target of 6-7% of the purchase price per year.

1987-02-01

75

Evaluation of diagnostic digital radiography of the chest in comparison with conventional chest x-ray films  

International Nuclear Information System (INIS)

Digital radiography for diagnosis of chest diseases using Fuji Computed Radiography (FCR) was evaluated. The results were as follows; 1. Compared to the conventional chest X-ray films, various types of image enhancement could be made by manipulation of the digital information such as tone conversion, spatial frequency modification etc. 2. Digital radiography lessens the X-ray exposure dose and will ultimately permit speedy transmission of image data from outlying clinics to central processing hospitals. 3. Digital radiographic images are useful in chest X-ray diagnosis especially in mass surveys for lung cancer and in primary care medicine because of its full imaging capability. (author).

1983-01-01

76

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...

1993-12-01

77

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

78

Uranium (VI)Bis(imido) chalcogenate complexes:synthesis and density functional theory analysis  

Energy Technology Data Exchange (ETDEWEB)

Bis(imido) uranium(VI) trans- and cis-dichalcogenate complexes with the general formula U(NtBu)2(EAr)2(OPPh3)2 (EAr = O-2-tBuC6H4, SPh, SePh, TePh) and U(NtBu)2(EAr)2(R2bpy) (EAr = SPh, SePh, TePh) (R2bpy = 4,4'-disubstituted-2,2'-bipyridyl, R = Me, tBu) have been prepared. This family of complexes includes the first reported monodentate selenolate and tellurolate complexes of uranium(VI). Density functional theory calculations show that covalent interactions in the U-E bond increase in the trans-dichalcogenate series U(NtBu)2(EAr)2(OPPh3)2 as the size of the chalcogenate donor increases and that both 5f and 6d orbital participation is important in the M-E bonds of U-S, U-Se, and U-Te complexes.

2009-01-01

79

Technetium complexes as potential brain imaging agents  

International Nuclear Information System (INIS)

Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).

80

Bilateral lipoma arborescens of the bicipitoradial bursa  

International Nuclear Information System (INIS)

A 37-year-old military mechanic presented to our institution with a chronic history of a slowly enlarging left elbow antecubital fossa mass. There was no history of other chronic illness or trauma. Magnetic resonance imaging (MRI) and excisional biopsy revealed fatty villi and synovial inflammation within the left bicipitoradial bursa, consistent with lipoma arborescens. Four years later the patient presented with a 6-month history of swelling at the antecubital fossa of the opposite elbow. Diagnostic computed tomography and MRI examinations were performed. The surgical and pathologic findings confirmed the imaging diagnosis of lipoma arborescens at the right bicipitoradial bursa. (orig.)

2002-11-01

81

CT versus MRI in the study of the articular diseases of the knee  

International Nuclear Information System (INIS)

The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the ...

1988-01-01

82

Optical diagnostics for turbulent and multiphase flows: Particle image velocimetry and photorefractive optics  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due to several experimental difficulties were ...

1997-01-01

83

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising ...

1993-12-31

84

Roentgenologic appearance of a thorotrast-induced small cholangiocarcinoma in a case of thorotrastosis  

International Nuclear Information System (INIS)

A small cholangiocarcinoma was detected at autopsy in a patient with thorotrastosis who died from the rupture of esophageal varices at the esophagogastric junction. Prior to the advent of recent diagnostic imaging technique, a correct antemortem diagnosis could only be obtained from tumor markers. However, the tendency for the opacity of the liver to decrease slowly with time and develop uneven trabeculation suggests that small tumors may be difficult to detect against such a non-homogeneous background. (author).

85

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

86

Optimisation of imaging technique used in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...

2006-09-15

87

Optimisation of imaging technique used in direct digital radiography  

International Nuclear Information System (INIS)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. The fact that all ...

2006-09-01

88

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in ...

2008-12-15

89

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the ...

1996-12-31

90

Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers  

International Nuclear Information System (INIS)

To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node ...

2003-02-01

91

Diagnostic and therapeutic evaluation of "1"1"1In-vinorelbine-liposomes in a human colorectal carcinoma HT-29/luc-bearing animal model  

International Nuclear Information System (INIS)

Colorectal carcinoma is a highly prevalent and common cause of cancer in Taiwan. There is still no available cure for this malignant disease. To address this issue, we applied the multimodality of molecular imaging to explore the efficacy of diagnostic and therapeutic nanoradiopharmaceuticals in an animal model of human colorectal adenocarcinoma [colorectal cancer (CRC)] that stably expresses luciferase (luc) as a reporter. In this study, an in vivo therapeutic efficacy evaluation of dual-nanoliposome (100 nm in diameter) encaged vinorelbine (VNB) and "1"1"1In-oxine on HT-29/luc mouse xenografts was carried out. HT-29/luc tumor cells were transplanted subcutaneously into male SCID mice. Multimodality of molecular imaging approaches including bioluminescence imaging (BLI), gamma scintigraphy, whole-body autoradiography (WBAR) and in vivo tumor growth tracing, histopathology and biochemistry/hematology ...

2008-07-01

92

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients  

International Nuclear Information System (INIS)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps ...

2000-06-01

93

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital ...

1981-01-01

94

Computer vision algorithms in DNA ploidy image analysis  

Science.gov (United States)

The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation ...

2006-03-01

95

Interaction of dioxygen with the electronic excited state of Ir(III) and Ru(II) complexes: Principles and biomedical applications  

British Library Electronic Table of Contents (United Kingdom)

Luminescent transition metal complexes are enjoying a growing interest because of their ubiquitous applications in, e.g., the fields of material science, sensors and (biomedical) diagnostics, and iridium(III) and ruthenium(II) complexes are among the best studied. Due to their long-living excited states, these complexes can have a strong interaction with dioxygen, resulting in luminescence quenching. This oxygen quenching might be regarded as an unwanted effect in luminescence imaging, but, on the other hand, it can be exploited for diagnostic and therapeutic applications as well. After a theoretical introduction concerning the dioxygen quenching mechanism and the parameters involved, in the second part of this review we focus on the possibility of tailoring this quenching by modifying sel...

2011-01-01

96

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-11-01

97

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-01-01

98

[Validity of the tympanic infrared thermometer in geriatric inpatients].  

Science.gov (United States)

The purpose of this study was to assess the agreement between rectal temperature and infrared emission detection (IRED). The specificity and sensitivity, the positive predictive value and the negative predictive value were calculated. It was a prospective, observational and unblinded study. Thermoscan-pro-1 was used to collect pairs of data in 41 patients, all hospitalised on an acute geriatric ward during a 4-month period. 41% of the patients were febrile. The 'bias' between rectal and tympanic measurement (left ear) was -0.64 degree C (d) and the standard deviation 0.58 degree C (s). The '95% Confidence Interval' for the bias was -0.82 degree C and -0.46 degree C. The '95% limits of agreement' between the rectal measurement and the tympanic measurement (left ear) was -1.78 degrees C and 0.50 degree C. Regression analysis taught us that bias was increasing with increasing temperature. If we take into account one measurement with the IRED ...

2001-10-01

99

Virtual adult ears reveal the roles of acoustical factors and experience in auditory space map development  

UK PubMed Central (United Kingdom)

Auditory neurons in the superior colliculus (SC) respond preferentially to sounds from restricted directions to form a map of auditory space. The development of this representation is shaped...Full Text Available

2008-11-05

100

Efferent Control of Hair Cell and Afferent Responses in the Semicircular Canals  

UK PubMed Central (United Kingdom)

The sensations of sound and motion generated by the inner ear are controlled by the brain through extensive centripetal innervation originating within the brain stem. In the semicircular canals, brain...Full Text Available

2009-09-01

101

At-Risk Populations  

Science.gov (United States)

... hearing protection since you play, sit or stand near loud instruments and speakers. Here are a few ... piper's calling you to join him" Led Zeppelin (Robert Plant), "Stairway to Heaven" "My ears are ringin' ...

102

Comparison of turbo inversion recovery magnitude (TIRM) with T2-weighted turbo spin-echo and T1-weighted spin-echo MR imaging in the early diagnosis of acute osteomyelitis in children  

Energy Technology Data Exchange (ETDEWEB)

Objective. To compare turbo inversion recovery magnitude (TIRM) with standard T1-weighted (T1-W) and T2-weighted (T2-W) MR sequences in the very early detection of acute osteomyelitis in children. Materials and methods. In 15 children with osteomyelitis, 15 sets of T1-W spin-echo (SE) (TR/TE, 400-640/12-17), T2-W turbo spin-echo (TSE) (TR/TE/ETL, 3290-4465/112-120/11), and TIRM (TR/TE/TI, 4000-6120/60/160) images were acquired with a 1.0-T magnet. Contrast-to-noise (C/N) ratios and percentage of signal between lesion and normal bone marrow were analysed with a computer-assisted image analysing system in a region of interest (ROI). Results. In 13 of 15 patients, the absolute signal enhancement in a ROI on the TIRM images was better than on the T1-W SE and T2-W TSE images and in 14 of 15 cases, C/N ratios were also better on the TIRM images than on the other sequences. In the other ...

1998-11-01

103

What, why, and when we image: considerations for diagnostic imaging and clinical research in the Children's Oncology Group  

Energy Technology Data Exchange (ETDEWEB)

Success in improving treatment outcomes in childhood cancer has been achieved almost exclusively through multicenter and multidisciplinary clinical and applied research over several decades. While biologically rational as well as empirical approaches have led to combination chemotherapy and multimodality approaches to therapy, which have given rise to evidence-based practice standards, similar scientific rigor has not always been as evidently applied to modalities utilized to assess initial disease burden and, more important, response to investigational approaches to therapy. As the empirical approach to therapeutic advances has likely maximized its benefit, future progress will require translation of biologic discovery most notably from the areas of genomics and proteomics. Hence, attempts to improve efficacy of therapy will require a parallel effort to minimize collateral damage of future therapeutic approaches, and such a parallel approach will mandate the continued dependence on ...

2009-02-15

104

General fundamentals of radiological diagnostics. Specific diagnostic radiology: Throat, mediastinum, diaphragm, mammary gland, infant thorax. 7. rev. ed.  

International Nuclear Information System (INIS)

The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR imaging open the view ...

105

Clinical application of dual energy subtraction in direct digital radiography of chest  

International Nuclear Information System (INIS)

Objective: To discuss the clinical application value of dual energy subtraction (DES) in direct digital radiography of chest. Methods: 83 cases of chest digital radiography(DR) using double-energy subtraction (DES) were randomly selected, and three posterior-anterior (PA) chest films (standard image, bone image and soft tissue image) were obtained in each case, which is so called 'bone and soft tissue separated' technology. Results: With the aid of double energy subtraction (DES), the bony chest was subtracted, the sensitivity and specificity of pulmonary calcification were improved, and sensitivity of pulmonary nodes was also improved, enhancing the distinction between pulmonary benign or malignant lesions, enlightening the diagnosis of chest cage lesions, and showing a clear superiority in the detection of pulmonary nodes comparing to common chest films. The double energy subtraction (DES) films showed a higher ...

2009-02-01

106

Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging); Moeglichkeiten der digitalen Bildverstaerkerradiographie am Beispiel des Digital Spot Imaging (DSI)  

Energy Technology Data Exchange (ETDEWEB)

We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the ...

1995-10-01

107

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...

108

MR evaluation of rectal carcinoma: pelvic phased-array coil versus endorectal-pelvic phased-array coil  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader ...

1998-10-01

109

Le leucodistrofie: aspetti clinici e quadri con Tomografia Computerizzata e con Risonanza Magnetica  

International Nuclear Information System (INIS)

Leukodystrophies are inherited white matter diseases due to abnormalities occurring in myelin synthesis and/or maintenance. The most common types of these rare childhood conditions are represented by adrenoleukodystrophy, metachromatic leukodystrophy, Canavan's, Alexander's, Krabbe's, and Pelizaeus-Merzbacher's diseases. Most of them are lethal during childhood, with the exception of the adrenoleukodystrophy-adrenomyeloneuropathy complex, which sometimes, during its early phases, may be cured with a dietary therapy. The aims of this paper are: 1) the description of inheritance factors, pathogenesis, pathological and clinical findings of each of the most frequent childhood leukodystrophies; 2) the description of the most common patterns of these conditions on CT and MR imaging; 3) the evaluation of the diagnostic capabilities of these two imaging techniques and the comparison of their results. Finally, some of the therapies ...

1991-01-01

110

Diagnostic imaging and interventional radiology of the amoebic liver abscess. Personal experience; Diagnostica per immagini e radiologia interventistica degli ascessi amebici del fegato: esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic imaging findings in hepatic amoebiasis and the capabilities of percutaneous drainage have already been described but some debate is open on both diagnosis and treatment. It is reported the experience with the ultrasound (US) and Computed Tomography (CT) studies of the hepatic amoebic abscess and its management. [Italian] I reperti con diagnostica per immagini nell'amebiasi epatica e le possibilita' del drenaggio percutaneo sono stati gia' illustrati; esistono tuttavia controversie sul piano sia diagnostico che terapeutico. Obiettivo di questo lavoro e' quello di riportare l'esperienza personale nella diagnostica con ecografia e tomografia computerizzata (TC) e nel trattamento degli ascessi amebici del fegato.

1999-10-01

111

Diagnostic difficulties in extraosseous Ewing's sarcoma: A proposal for diagnostic criteria  

International Nuclear Information System (INIS)

Five cases diagnosed as extraosseous Ewing's sarcoma (EES) during a 15 year period, and the relevant literature, were reviewed. The diagnosis in these cases was difficult to confirm, mainly because the distinction between the osseous form of Ewing's sarcoma (OES) and either periosteal reactions or direct tumour invasion into adjacent bone by EES was often unclear. The literature suggests that other authors have also encountered difficulties. The authors believe that many cases reported as EES are likely to have been OES. This distinction has some importance, as the two conditions are usually treated in differing ways. The following criteria are proposed for the diagnosis of primary EES: (i) no evidence of bony involvement on magnetic resonance imaging; (ii) no evidence of increased uptake in bone or periosteum adjacent to the tumour on static isotope bone scan images; (iii) a small round cell tumour with no differentiating features on light ...

112

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, ...

2008-07-01

113

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences; Funktionelle MRT des Pharynx bei obstruktiver Schlafapnoe (OSA) mit schnellen 2D-FLASH-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic ...

1996-03-01

114

Seismic and Rockphysics Diagnostics fo Multiscale Reservoir Textures  

Energy Technology Data Exchange (ETDEWEB)

We have continued to finish up our work on analyzing relationships between elastic properties and rock microstructure. We have worked on theoretical models for the effects of sorting and packing on elastic moduli and seismic velocities. After analyzing the scanning acoustic images of shales to quantify textures at different scales, we are now using theoretical inclusion models to quantify the elastic property variation with texture. In the closing phases of this project most of our efforts are now focused on writing up the results and preparing the final reports.

2005-02-01

115

Analysis of brain CT on 120 patients of human cysticercosis  

International Nuclear Information System (INIS)

A study on brain CT was made in 120 patients of human cysticercosis, which is a rare disease in Japan and clinical symptoms and laboratory data for the diagnosis were also discussed. From the point of therapeutic view, we proposed a new differentiation on brain CT of human cysticercosis, which is divided into two groups according to the alve or dead parasite. Furthermore, we proposed a new type named multiple large and small cysts type on brain CT. The idea of diagnostic standard was made integrating brain CT image, clinical symptoms and labolatory data. (author).

116

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.

1988-01-01

117

Inflammatory spine disease as a cause of back pain  

International Nuclear Information System (INIS)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-#alpha# antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-#alpha# antagonists is based on clinical and laboratory criteria, and signs of ...

2006-06-01

118

Chemical Reactor Diagnostics  

International Science & Technology Center (ISTC)

Development of Methods and Apparatus for Processes Diagnostics in Plasma Reactors at the Neutralization of Chemical Herbiside and Pestiside

119

Beam Diagnostic System for High Intensity Proton Linac at KAERI  

CERN Document Server

Beam Diagnostic System for High Intensity Proton Linac at KAERI

2003-01-01

120

Value of ultrasonography, Ct and MR imaging in the diagnosis of primary hyperparathyroidism  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the significance of preoperative localization of abnormal parathyroid glands to the surgical outcome in patients with primary hyperparathyroidism. Material and Methods: Thirty-nine patients with primary hyperparathyroidism were studied preoperatively with US (39 patients), CT (30 patients) and MR imaging (18 patients). The overall diagnostic accuracy for US was 87%, CT 66% and MR 94%. In patients with a single parathyroid adenoma US was the most cost-effective localization technique with a detection rate of 96%. CT had a lower detection rate (78%) but was of particular value for fairly large ectopic adenomas in the root of the neck. MR imaging was a good confirmatory test (93%). In patients with multiple gland disease (primary hyperplasia and multiple adenomas), no single localization study alone was sufficient. Combination of all 3 studies, however, alerted the physician to the presence of disease in ...

1996-09-01

121

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression ...

2003-12-01

122

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The ...

2003-12-01

123

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively ...

2007-12-15

124

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after radiation therapy. Three of them presented with transient ischemic ...

1997-05-01

125

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, ...

1995-08-01

126

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images ...

1995-01-01

127

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, ...

2001-07-01

128

High-End CT for clinical and scientific applications; High-End-CT im klinischen und wissenschaftlichen Einsatz  

Energy Technology Data Exchange (ETDEWEB)

The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die ...

1997-12-01

129

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE); Ein neuer Ansatz in der Magnetresonanztomographie der Lunge mit einer ultrakurzen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good ...

1996-05-01

130

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

131

Magnetic resonance imaging in multiple sclerosis. Imagerie nouvelle par resonance magnetique nucleaire au cours de la sclerose en plaques  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of ...

1991-09-15

132

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only ...

1990-04-01

133

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

International Nuclear Information System (INIS)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only ...

1990-01-01

134

Locally Optimally-emitting Clouds and the Narrow Emission Lines in Seyfert Galaxies  

CERN Document Server

The narrow emission line spectra of active galactic nuclei are not accurately described by simple photoionization models of single clouds. Recent Hubble Space Telescope images of Seyfert 2 galaxies show that these objects are rich with ionization cones, knots, filaments, and strands of ionized gas. Here we extend to the narrow line region the ``locally optimally emitting cloud'' (LOC) model, in which the observed spectra are predominantly determined by powerful selection effects. We present a large grid of photoionization models covering a wide range of physical conditions and show the optimal conditions for producing many of the strongest emission lines. We show that the integrated narrow line spectrum can be predicted by an integration of an ensemble of clouds, and we present these results in the form of diagnostic line ratio diagrams making comparisons with observations. We also predict key diagnostic line ratios as a ...

1997-01-01

135

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...

1981-11-01

136

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. Future applications of CT include the staging of mediastinal ...

137

Unsolved problems in the diagnosis and surgical treatment of intramedullary tumors  

Energy Technology Data Exchange (ETDEWEB)

Problems and solutions in the diagnosis and operative treatment were clarified by retrospective evaluation of cases of intramedullary tumor in which MRI and surgery had been performed. The subjects were 16 patients (21-75 years old, mean age: 45 years) whose tumor was surgically removed between 1991 and 1998. MRI was performed preoperatively, and T1-weighted images, T2-weighted images, and enhanced images were obtained. Angiography was also performed in some cases. The histological diagnosis based on the MRI findings before surgery were compared with the pathological diagnosis after the operation. In 9/16 cases (56%), the preoperative histological diagnosis based on the MR images was the same as the pathological diagnosis after the operation. In 8 of the 11 cases (73%) whose images showed clear tumor margins and well shaped the tumor, the tumors were completely removed. The ...

2001-04-01

138

Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter  

Energy Technology Data Exchange (ETDEWEB)

Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten ...

2002-06-01

140

Modern Optical Diagnostics for Technical Combustion Research  

ScienceCinema

...different sparking language english ? ...

142

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) ...

2003-12-01

143

Radiopharmaceuticals labelled with positron emitting radionuclides  

International Nuclear Information System (INIS)

A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.

1989-01-01

144

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

145

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

146

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in characterising recurrent masses and this improved the differentiation between scarring and local tumour recurrence. (orig.).

147

Early spondyloarthropathy: scintigraphic, biological, and clinical findings in MRI-positive patients  

British Library Electronic Table of Contents (United Kingdom)

There are no specific diagnostic tests or a gold standard method for measuring disease activity and outcome in spondyloarthropathies (SpA). Many different methods have been developed to assess the signs and symptoms in SpA. The aim of this study was to evaluate the value of scintigraphy, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and Bath Ankilosing Spondylitis Disease Activity Index (BASDAI) in the evaluation of disease activity in early axial SpA diagnosed with magnetic resonance imaging (MRI). Thirty early MRI-positive axial SpA patients (23 males, 7 females) with a median age of 35 (18?55) years and a median duration of inflammatory low back pain of 24 (8?60) months were included in the study. In the patients with sacroiliitis, the sensitivity, specificity, and pos...

2008-01-01

148

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

149

Adrenal incidentaloma: Does an adequate workup rule out surprises?  

British Library Electronic Table of Contents (United Kingdom)

Background Adrenal incidentaloma remains a diagnostic challenge. Despite well-established management guidelines, the long-term results of following these guidelines are unknown. We sought to determine how accurately these guidelines identify functioning incidentalomas and how often these guidelines result in adrenalectomy for benign tumors. Methods We catalogued adrenal incidentalomas from a retrospective review of 500 consecutive adrenalectomies at a single institution. The outcome measures studied were patient demographics, preoperative biochemical analysis, imaging characteristics, tumor size, type of operation performed, and postoperative histologic diagnosis. Results Eighty-one of the 500 adrenalectomies performed were for incidentalomas. Size was the only significant characteristic t...

2010-01-01

150

Adenopathies in lung cancer: a comparison of pathology, Computed Tomography and endoscopic ultrasound findings  

International Nuclear Information System (INIS)

A prospective comparative study with pathology was performed to assess the clinical value of Computed Tomography (CT) and endoscopic ultrasound (EUS) for nodal staging in lung cancer. A total of 329 nodal stations were dissected or sampled and 755 lymph nodes were examined at histology. On a pre-station basis, CT had greater sensitivity (74%) than EUS (56%), but EUS was more specific (83% versus 93%). The accuracy rates of the two techniques were similar. In conclusion, endoscopic ultrasound should be part of a routine preoperative diagnostic approach to non-small-cell lung cancer., because of its high specificity. Results can be improved when EUS and CT are combined., which suggests that these imaging modalities should be used together in selected patients for the noninvasive staging of non-small-cell lung cancer to identify local lymphatic spread.

1999-01-01

151

A real-time neutron radiography diagnostic of a vertical co-current two-phase flow channel with a hexagonal finned bundle  

International Nuclear Information System (INIS)

A Real-Time Neutron Radiography (RTNR) system is developed to determine two-phase flow parameters for a vertical co-current two-phase flow channel with a hexagonal finned bundle. Image processing techniques are applied to visualize the two-phase flow, and procedures for measuring flow regime, cross-sectional averaged void fraction, time averaged void fraction, and void distribution for this complex geometry are discussed. The results show that the experimental flow regime map agrees well with an existing flow regime model for a hexagonal fined bundle. The hexagonal finned bundle is observed to significantly affect the void fraction, void migration, and void fluctuation along the axial flow channel.

2003-06-01

152

Lesion localization in patients with hyperparathyroidism using double-phase Tc-99m MIBI parathyroid scintigraphy  

International Nuclear Information System (INIS)

This study was performed to evaluate the diagnostic usefulness of double-phase Tc-99m MIBI parathyroid scintigraphy with single photon emission computed tomography (SPECT) in patients with hyperparathyroidism. We also evaluated the relationship between Tc-99m MIBI uptake and oxyphil cell contents in parathyroid glands. The subjects were 28 parathyroid glands of 10 patients who underwent Tc-99m MIBI parathyroid scintigraphy and parathyroidectomy for clinically suspected hyperparathyroidism. Early and delayed pinhole images were obtained at 15 minutes and 2 hours after injection of Tc-99m MIBI, and SPECT images were followed. The weight and oxyphil cell contents of parathyroid tissue were obtained from pathologic specimen, and the scintigraphic findings were compared with histopathology. In surgical histopathology, 6 parathyroid adenomas and 9 parathyroid hyperplasias were confirmed. The sensitivity, specificity, and positive ...

1999-02-01

153

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, ...

1985-01-01

154

Mucociliary transport and upper airway disease  

International Nuclear Information System (INIS)

Mucociliary transport so critical in nasal, paranasal sinus, and middle ear physiology is impaired in chronic sinsusitis and otitis media by factors such as increased mucus viscoelasticity, decreased ciliary area, and primary or secondary ciliary immotility. We reviewed the pathophysiology of primary ciliary dyskinesia, otitis media with effusion, chronic sinusitis, and allergic rhinitis in terms of mucociliary transport. Subjects with primary ciliary dyskinesia may experience recurrent middle ear infection, chronic airway infection, predominantly lower-lobe bronchiectasis, male sterility, or situs inversus. Primary ciliary dyskinesia is sometimes difficult to diagnose in cases without situs inversus. Nasal nitric oxide concentration in such patients decreases, although why is unclear. Mutations may involve dynein arm intermediate chain 1 (DNAI1) or dynein arm heavy chain 5 (DNAH5). Mucociliary clearance decreases more in those with otitis ...

2010-05-01

155

Metabolomic analysis of the plant pathogenic fungi Fusarium graminearum and Fusarium culmorum  

Environmental Research Database

DescriptionThis project is part of the BBSRCs special initiative on plant and microbial metabolomics. The project will primarily focus on the trichothecene mycotoxin producing Ascomycete fungus Fusarium graminearum (Fg) which causes ear blight disease of small grain cereals. The project aims to explore the metabolome of various wild-type and single gene deletion Fg strains and to compare some of these with the identical gene mutation in the budding yeast, S. cerevisiae (Sc) and the saprophytic filamentous [continued...

2008-01-31

156

Portable fluid X-ray diagnostic system  

Energy Technology Data Exchange (ETDEWEB)

A portable X-ray image system is described comprising: (a) a base assembly including panels and hinges joining the panels together along edges, and compression stops for biasing the hinges to compensate for the weight of payload when mounted on the base assembly, the compression stops being located for interaction with the hinges for biasing the panels to exhibit upward bowing when laid upon a flat surface prior to loading, and to provide resiliency for facilitating the base assembly assuming a substantially flat configuration when a predetermined payload is placed upon the base assembly; (b) an X-ray member; (c) apparatus for detachably mounting a table member to the base assembly to hold the table member at a location above the base; (d) an X-ray source; (e) means for sensing X-rays to form an image; (f) means for mounting the X-ray source and the X-ray sensing means on opposite sides relative to the table member and supported by the base ...

1989-02-14

157

Normal and abnormal water diffusion in the brain  

International Nuclear Information System (INIS)

Diffusion magnetic resonance imaging (MRI) has become an important tool in the radiologic diagnosis of diseases of the brain as it measures molecular motion of water that characterizes the microstructure of tissues. Its most important clinical use to date is the early detection of cerebral ischemia by revealing the ischemic injury shortly after vessel occlusion and simultaneously providing therapy-relevant information on the tissue at risk. Furthermore, diffusion MRI is diagnostically promising in other diseases of the brain and is thus increasingly becoming part of routine clinical protocols in the diagnosis of tumors, inflammation, trauma, demyelination, dysmyelination and neurodegeneration. Although abnormalities of diffusion are generally not pathognomonic, diffusion MRI affords information about tissue changes for specific disorders that complements information obtained with standard MR techniques and frequently shows pathology earlier. In ...

2003-10-01

158

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI ...

2000-05-01

159

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-12-01

160

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation ...

1984-01-01

161

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil; Lymphknotenstaging beim Zervixkarzinom: Ergebnisse der hochaufloesenden Magnetresonanztomographie (MRT) mit einer Phased-Array-Koerperspule  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings ...

1997-03-01

162

High-resolution brain SPECT imaging in attention deficit hyperactivity disorder children without comorbidity: quantitative analysis using statistical parametric mapping(SPM)  

Energy Technology Data Exchange (ETDEWEB)

We examined the abnormalities of regional cerebral blood flow(rCBF) in children with attention deficit hyperactivity disorder(ADHD) without comorbidity using statistical parametric mapping(SPM) method. We used the patients with not compatible to DSM-IV diagnostic criteria of ADHD and normal rCBF pattern in visual analysis as normal control children. Tc-99m ECD brain SPECT was performed on 75 patients (M:F=64:11, 10.0{+-}2.5y) with the DSM-IV diagnostic criteria of ADHD and 13 normal control children (M:F=9:4, 10.3{+-}4.1y). Using SPM method, we compared patient group's SPECT images with those of 13 control subjects and measured the extent of the area with significant hypoperfusion(p<0.01) in predefined 34 cerebral regions. Only on area of left temporal lobe showed significant hypoperfusion in ADHD patients without comorbidity (n=75) compared with control subjects(n=13). (n=75, p<0.01, extent ...

2002-07-01

163

Neutron detection techniques for plasma diagnostics at the Joint European Torus (JET)  

International Nuclear Information System (INIS)

The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.

165

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems ...

2004-12-01

166

Proton storage ring (PSR) diagnostics and control system  

Energy Technology Data Exchange (ETDEWEB)

When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.

1983-01-01

167

The Development of a Dental Diagnostic Terminology  

UK PubMed Central (United Kingdom)

There is no commonly accepted standardized terminology for oral diagnoses. The purpose of this article is to report the development of a standardized dental diagnostic terminology by a work...Full Text Available

2011-01-01

168

Insertion Loss of Personal Protective Clothing  

Energy Technology Data Exchange (ETDEWEB)

'The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing''s noise reduction rating ...

1999-05-13

169

Influence of sewage sludge compost applications on uptake of element by cultivated crops in a brown forest soil. Measurement by neutron activation analysis  

International Nuclear Information System (INIS)

A field study was conducted to investigate the absorption of various elements into oats and carrots cultivated in brown forest soil after three years' applications of chemical fertilizer and two types of sewage sludge compost mixed with sawdust (SD compost) or rice husk (RH compost). The results obtained in this study are summarized as follows. 1) The application of SD compost led to a significant increase on the concentrations of Mn, Zn, Ag and Ba in oat root, of Zn and Br in oat shoot, of Cl and Zn in oat ears, of Mg, Sc, Mn, Zn, Br, Ba and La in carrot peel, of Mn, Fe, Co and Zn in carrot edible portion and of Na, Sc, Mn, Fe, Co and Sm in carrot shoot. 2) The application of RH compost increased the concentrations of Mn, Zn, and Ag in oat root, of K, Cr, Mn, Zn and Br in oat shoot, of Zn and Br in oat ears, of Mg, Mn and Br in carrot peel, of Cl, Mn, Zn and Br in carrot edible portion and of Na, Mn, Zn, Br and Sm in carrot shoot. (author)

2006-03-01

170

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as ...

2003-07-01

171

Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy  

International Nuclear Information System (INIS)

Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or ...

1990-08-26

172

Performance study of teleradiology network systems with CRT monitors. ROC analysis of an observation study of simulated lung nodules  

International Nuclear Information System (INIS)

To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to ...

173

ICPES analyses using full image spectra and astronomical data fitting algorithms to provide diagnostic and result information  

Energy Technology Data Exchange (ETDEWEB)

ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of organics on the analyses and calcium and argon lines can be ...

1997-10-01

174

APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs  

Energy Technology Data Exchange (ETDEWEB)

A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified ...

1992-07-01

175

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

176

Study of proton therapy on malignant tumors. Effects in twenty-four hours after proton irradiation  

Energy Technology Data Exchange (ETDEWEB)

We irradiated proton beams on the ears of rabbits and the Harding-Passey mouse melanoma and observed their morphological change. We used 52 MeV proton beams from the INS-FM cyclotron. We adjusted the energy of the proton beams to be at the plateau part of the Bragg curve, at the half-way point of the Bragg peak, and at the Bragg peak. The amount of radiation was 5000rad in each case. The Harding-Passey mouse melanoma was transplanted into the subcutan of a three week old mouse. In this experiment, we used tumors, the diameter of which grew up to 1.5-2cm in 2-3 weeks after the transplantation. Using the jroscope, we observed both lightly and severely damaged cells. Using proton irradiation with the Bragg peak located at depth of 1mm in the rabbit's ears, we studied the change in the tissue. Irradiated epidermis fell off and was eroded because of radiation damage, but the rear surface of the rabbit's ears ...

1983-01-01

177

The clinical significance of Fuji computed radiography on lateral chest radiogram  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...

1995-02-01

178

The clinical significance of Fuji computed radiography on lateral chest radiogram  

International Nuclear Information System (INIS)

The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, while FCR was superior ...

1995-01-01

179

Infrarenal abdominal aortic aneurysm. Endovascular repair with stent grafts; Infrarenales Bauchaortenaneurysma. Endovaskulaere Stent-Graft-Therapie  

Energy Technology Data Exchange (ETDEWEB)

As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich ...

2008-09-15

180

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = 0.749). Mean per-polyp sensitivity for lesions ...

2010-02-15

181

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the code GENESIS.

2002-07-01

182

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the code GENESIS.

2001-12-21

183

The diagnostic value of MRI and gadolinium-DTPA compared with CT for the diagnosis of bladder tumours  

International Nuclear Information System (INIS)

In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between superficial and intramural spread. MRI was better than CT at demonstrating tumours in the roof of the ...

184

The detection of spiral arm modulation in the stellar disk of an optically flocculent and an optically grand design galaxy  

CERN Document Server

Two dimensional Fourier spectra of near-infrared images of galaxies provide a powerful diagnostic tool for the detection of spiral arm modulation in stellar disks. Spiral arm modulation may be understood in terms of interference patterns of outgoing and incoming density wave packets or modes. The brightness along a spiral arm will be increased where two wave crests meet and constructively interfere, but will be decreased where a wave crest and a wave trough destructively interfere. Spiral arm modulation has hitherto only been detected in grand design spirals (such as Messier 81). Spiral arm amplitude variations have the potential to become a powerful constraint for the study of galactic dynamics. We illustrate our method in two galaxies: NGC 4062 and NGC 5248. In both cases, we have detected trailing and leading m=2 waves with similar pitch angles. This suggests that the amplification mechanism is the WASER type II. In this mechanism, the bulge ...

2000-01-01

185

Spectroscopic studies on the interaction of the antibiotic lasalocid A (x-537a) with technetium (V) ions in methanol  

International Nuclear Information System (INIS)

In the present study, the authors examine the interactions of pentavalent technetium ions (TcO/sup 3+/) with the basic form of the lasalocid A in pure methanol solvent and in methanol-water mixtures. There are a number of reasons for such a study. First, the interactions of technetium ions with biologically important compounds are of considerable importance owing to the widespread use of /sup 99m/Tc in diagnostic radio-imaging. Second, lasalocid A is known to transport metal ions across phospholipid bilayer membranes and between the aqueous cores of phospholipid inverse micelles. Third, lasalocid A is known to bind and solubilize metal ions in bulk organic liquid phases. Fourth, the conformation adopted by lasalocid A on interaction with TcO/sup 3+/ appears to be different than those found in most other cases and circumstances. Fifth, it may also be possible to use the competition of TcO/sup 3+/ with other, physiologically relevant cations ...

186

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. Current safety ...

2009-03-01

187

Quantitative bone scintigraphy in renal osteodystrophy  

International Nuclear Information System (INIS)

The need for noninvasive sensitive techniques for the diagnosis and follow-up of metabolic bone disease in dialysis patients has stimulated the author's interest in the efficacy of more detailed quantitative bone scintigraphy. Using hemodialysis to reduce elevated soft-tissue activity at scintigraphy, an attempt was made to assess the diagnostic sensitivity of quantitative bone scintigraphy as compared to qualitative bone scintigraphic, biochemical, radiographic and bone histologic studies. The second aim of these studies was to determine if one of the two major components of renal osteodystrophy is a major determinant for skeletal radiotracer uptake. The clinical observations on the efficacy and possible specificity of quantitative bone scintigraphy in the diagnosis and follow-up during treatment of renal osteodystrophy are presented briefly in this chapter. Thus, the use of scintigraphy for the routine detection and follow-up of renal osteodystrophy in dialysis ...

188

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and analysis presented ...

2011-01-01

189

Non-white noise in fMRI: does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the literature. Subsequently, we ...

2005-01-01

190

Non-white noise in fMRI: Does modelling have an impact?  

DEFF Research Database (Denmark)

The sources of non-white noise in Blood Oxygenation Level Dependent (BOLD) functional magnetic resonance imaging (fMRI) are many. Familiar sources include low-frequency drift due to hardware imperfections, oscillatory noise due to respiration and cardiac pulsation and residual movement artefacts not accounted for by rigid body registration. These contributions give rise to temporal autocorrelation in the residuals of the fMRI signal and invalidate the statistical analysis as the errors are no longer independent. The low-frequency drift is often removed by high-pass filtering, and other effects are typically modelled as an autoregressive (AR) process. In this paper, we propose an alternative approach: Nuisance Variable Regression (NVR). By inclusion of confounding effects in a general linear model (GLM), we first confirm that the spatial distribution of the various fMRI noise sources is similar to what has already been described in the literature. Subsequently, we ...

2006-01-01

191

Iofetamine I 123 single photon emission computed tomography is accurate in the diagnosis of Alzheimer's disease  

Energy Technology Data Exchange (ETDEWEB)

To determine the diagnostic accuracy of iofetamine hydrochloride I 123 (IMP) with single photon emission computed tomography in Alzheimer's disease, we studied 58 patients with AD and 15 age-matched healthy control subjects. We used a qualitative method to assess regional IMP uptake in the entire brain and to rate image data sets as normal or abnormal without knowledge of subjects'clinical classification. The sensitivity and specificity of IMP with single photon emission computed tomography in AD were 88% and 87%, respectively. In 15 patients with mild cognitive deficits (Blessed Dementia Scale score, less than or equal to 10), sensitivity was 80%. With the use of a semiquantitative measure of regional cortical IMP uptake, the parietal lobes were the most functionally impaired in AD and the most strongly associated with the patients' Blessed Dementia Scale scores. These results indicated that IMP with single photon ...

1990-04-01

192

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to pluridirectional tomography because it is ...

1988-01-01

193

Herlyn-Werner-Wunderlich syndrome: uterus didelphys, blind hemivagina and ipsilateral renal agenesis. Sonographic and MR findings in 11 cases  

Energy Technology Data Exchange (ETDEWEB)

Uterus didelphys with obstructed hemivagina and ipsilateral renal agenesis is a rare entity, sometimes referred to as Herlyn-Werner-Wunderlich syndrome (HWW). It usually presents after menarche with progressive pelvic pain, sometimes with regular menses, and a palpable mass due to hemihaematocolpos. The diagnosis is generally made only if the suspicion of this genitourinary syndrome is raised. To highlight the imaging diagnostic clues in this rare condition. We report on 11 adolescents with this condition. Sonography mostly allowed the correct diagnosis by showing uterovaginal duplication, haematocolpos or haematometrocolpos, and the absence of the ipsilateral kidney. MRI provided more detailed information regarding uterine morphology, the continuity with each vaginal channel (obstructed and nonobstructed), and the bloody nature of the contents. Early and accurate diagnosis of this syndrome is important so that adequate and prompt surgical ...

2007-07-15

194

Development of new radiopharmaceuticals  

International Nuclear Information System (INIS)

The possibilities to design and prepare better and more organ-specific radiopharmaceuticals for diagnostic nuclear medicine has increased dramatically in the recent past with a deeper understanding of the relationships between chemical structure and biological activity. Whereas most of the research is performed in well-funded laboratories of industrialized countries, there are several developing countries with adequate resources and expertise as to undertake fruitful research in the field of radiopharmacy. With the aim of promoting advanced research in radiopharmacy by developing new radiodiagnostics agents, in particular, hepatobiliary imaging agents labelled with "9"9"mTc, and to facilitate exchange of information, the IAEA has established in 1983 the present Research Co-ordination Programme (CRP) with a duration of five years. The report includes detailed results obtained by all participants as well as novel preparation procedures for some ...

1988-09-12

195

Atlas and toolbook of MR mammography; Lehratlas der MR-Mammographie  

Energy Technology Data Exchange (ETDEWEB)

This richly illustrated toolbook and atlas contains information on all aspects of nmr diagnostic imaging of benign or malignant neoplasms of female and male mammary glands. It offers pinpointed guidance and insight for vocational training and continuing training of radiology assistants, students and medical radiologists. (orig./AJ) [German] Die MRT als hochaufloesendes und schaedigungsfreies Diagnostikum gewinnt gerade in der emotional stark besetzten Mammadiagnostik zunehmend an Bedeutung. Dennoch beherrschen nur wenige Zentren im deutschsprachigen Raum diese Technik, die - eine hohe Reproduzierbarkeit bei fehlender Belastung fuer die Patientin bietet, - invasive Karzinome bereits ab einer Groesse von 5 mm mit hoher Zuverlaessigkeit ausschliessen kann und - gerade bei widerspruechlichen Befunden zwischen klinischer Untersuchung, Roentgenmammographie und perkutaner Biopsie eine wesentliche Entscheidungshilfe bieten kann. Aus einem der ...

2000-07-01

196

Adenosine triphosphate loading thallium-201 myocardial scintigraphy. Optimal dose and diagnostic accuracy  

Energy Technology Data Exchange (ETDEWEB)

Adenosine triphosphate (ATP) is an alternative to dipyridamole or adenosine in thallium-201 myocardial scintigraphy. However, the optimal dose of ATP has not been determined. A Doppler guide wire study showed the coronary flow velocity at a dose of 0.15 mg/kg of ATP was equal or higher than that at 0.14 mg/kg of adenosine or 0.56 mg/kg of dipyridamole. ATP was given intravenously to 67 patients with coronary artery disease at 0.15 mg/kg/min for 6 min. Thallium-201 was injected at 3 min, followed by immediate and delayed (3 hrs) tomographic imaging. There was no serious side effect during examination, although chest pain (26%), dyspnea (17%), and flushing (33%) were common. The sensitivity and specificity to detect coronary artery disease were 98 and 100%, respectively. The sensitivity to detect left anterior descending artery, left circumflex artery, and right coronary artery lesions was 94, 59 and 77%, respectively. ATP loading thallium-201 scintigraphy provides ...

1995-01-01

197

Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 13. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results obtained during Stage 13 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A brief proposal for the continuation of this program in Stage 14 is also given at the end of the report. The program executed in Stage 13 consists of three parts and the work performed in each part is summarized below. 1. Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR). Although the original goal of the investigations of the MSR in Stage 13 was to calculate the neutron noise induced by the fluctuations of the fuel temperature, the study, solution and interpretation of the static problem, as well as to define an approximate version of the point kinetic approximation was necessary to perform. As it turned out, these tasks in themselves were more involved, and also very edifying, to solve. Hence, in this report, we confine the study of ...

2008-06-15

201

ELECTRICAL AND DIAGNOSTIC ASPECTS OF ELECTROHYDRAULIC AND MAGNETIC FORMING  

Science.gov (United States)

Discussion of an electrohydraulic and magnetic forming process

1963-01-01

204

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

206

Alternative Technologies for Medical Radionuclide Production  

International Science & Technology Center (ISTC)

Creation of Economic Alternative Technologies for Radionuclide Production for Medical Diagnostics and Therapy

207

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

208
209

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

210

Patterns of ovarian morphology in polycystic ovary syndrome: a study utilising magnetic resonance imaging  

Energy Technology Data Exchange (ETDEWEB)

To evaluate and compare MRI-based ovarian morphology in groups of women with polycystic ovary syndrome (PCOS) and controls. All PCOS cases (n = 44) had oligo-amenorrhoea and hyperandrogenism irrespective of ovarian morphology, and fulfilled NIH/Rotterdam diagnostic criteria for PCOS. All control women (n = 40) had normal menses and normoandrogenaemia. All subjects were of white British/Irish origin and pre-menopausal. Group comparisons were based on independent-sample t tests. Polycystic ovarian morphology was defined by at least 12 follicles 2-9 mm in diameter and/or an ovarian volume greater than 10 cm{sup 3}. Ovarian morphology differed significantly in PCOS cases and controls (follicle number geometric mean [SD range] 18.6 [9.9, 35.0] vs 6.6 [3.1, 14.2], unadjusted P = 1.3 x 10{sup -16}; calculated ovarian volume 8.8 cm{sup 3} [5.0, 15.5] vs 5.1 cm{sup 3} [2.5, 10.3], unadjusted P = 3.0 x 10{sup -7}; peripheral follicle location in 55% vs 18% of ovaries, P = ...

2010-05-15

211

Nuclear magnetic resonance spectroscopy in biomedicine. Course organized by the Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), September 18-23, 1995; Spettroscopia di risonanza magnetica nucleare in biomedicina. Corso organizzato dall`Istituto Superiore di Sanita`. Marciana Marina (Isola d`Elba), 18-23 settembre 1995  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance is a powerful technique that can be used in a wide range of applications, such as the structural characterization of high molecular weight molecules, conformational studies on enzymes in solution, enzyme-substrate or DNA-protein interactions, monitoring of cell metabolism in vivo, and for diagnostic purposes, employing spectroscopic and imaging techniques. This course was organized in order to introduce the participants to the fundamentals of NMR spectroscopy, and offer practical advice on performing NMR experiments on cell systems, cell and tissue extracts and animal models. The main implications regarding human experiments were also discussed. Finally the quantification of information and the interpretation of data were considered with regard to the main nuclei observed. [Italiano] La risonanza magnetica nucleare e` una delle tecniche spettroscopiche che meglio risponde all`ampio spettro di condizioni imposto dalla ...

1997-12-01

212

Magnetic resonance imaging of stents. Quantitative in vitro examination at 3 Tesla; Magnetresonanztomographie von Stents. Quantitative MR-Untersuchungen in vitro bei 3 Tesla  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to qualitatively and quantitatively study MR artifacts of various stents on the basis of in vitro experiments. We were particularly interested whether sequence type and orientation of the stent with respect to the static magnetic field influences the artifact. We examined 18 stents of different material (nitinol, stainless steel, cobalt alloy), different design of the stent meshes (AccuLink, OmniLink, DynaLink, Xact, Protoge, Wallstent Monorail), different diameter (5-10 mm) and different length (18-58 mm) with a turbo spin echo (TSE), a 2D-fast low angle shot (FLASH) and a 3D-FLASH sequence. The MR images were examined qualitatively with respect to possible artifacts. Furthermore we examined the MR data quantitatively: The contrast-noise-ratio (CNR) was determined both within the stent and outside (within the tube); based on these values we calculated the transparency factor P, furthermore we calculated the apparent vascular lumen within ...

2009-07-01

213

Disorders of brain development and phakomatosis  

International Nuclear Information System (INIS)

Full text: Disorders of brain development and phakomatosis are resulting from disturbed embryonic-foetal development One third of all major embryological anomalies involve CNS, and over 2000 different anomalies have been described. Anomalies of the brain often cause foetal and neonatal death, and mental and physical retardation in pediatric group. The majority of disorders of brain development and phakomatosis are idiopathic, and most of them are not hereditary or familial. Ultrasonography plays the important role in screening foetal and neonatal brain, but after closure of fontanels it is difficult to find the acoustic window. CT has limited contrast resolution, and disadvantage exposing infant to ionizing radiation. It is helpful to demonstrate the presence of calcifications. MR imaging has proved to be a diagnostic tool of major importance in children with disorders of brain development and phakomatosis. The excellent grey/white matter ...

214

A revised dosimetric model of the adult head and brain  

Energy Technology Data Exchange (ETDEWEB)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified ...

1996-06-01

215

A revised dosimetric model of the adult head and brain  

International Nuclear Information System (INIS)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified ...

1996-07-21

216

3D Fourier synthesis of a new X-ray picture identical in projection to a previous picture  

Energy Technology Data Exchange (ETDEWEB)

A central problem in diagnostic radiology is to compare a new X-ray picture with a previous picture and from this comparison be able to decide if anatomical changes have occurred in the patient or not. It is of primary interest that these pictures are identical in projection. If not it is difficult to decide with confidence if differences between the pictures are due to anatomical changes or differences in their projection geometry. In this thesis we present a non invasive method that makes it possible to find the relative changes in the projection geometry between the exposure of a previous picture and a new picture. The method presented is based on the projection slice theorem (central section theorem). Instead of an elaborate search for a single new picture a pre-planned set of pictures are exposed from a circular orbit above the patient. By using 3D Fourier transform techniques we are able to synthesize a new X-ray picture from this set of pictures that is ...

1993-11-01

217

Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients; Impiego dell'endoscopia virtuale con Tomografia Computerizzata nell'identificazione delle neoplasie colorettali. Studio prospettivo in pazienti sintomatici  

Energy Technology Data Exchange (ETDEWEB)

Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps ...

2000-06-01

218

Diagnostics hardening for harsh environment in Laser Megajoule (invited)  

International Nuclear Information System (INIS)

The diagnostic designs for the Laser Megajoule (LMJ) will require components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiations, and, in some cases, debris and shrapnel, at levels several orders of magnitude higher than those experienced today on existing facilities. The lessons learned about the vulnerabilities of present diagnostic parts fielded mainly on OMEGA for many years, have been very useful guide for the design of future LMJ diagnostics. The present and future LMJ diagnostic designs including this vulnerability approach and their main mitigation techniques will be presented together with the main characteristics of the LMJ facility that provide for diagnostic protection.

2008-10-01

219

Computed tomography whole body imaging in multi-trauma: 7 years experience  

International Nuclear Information System (INIS)

AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded ...

2006-04-01

220

National NIF Diagnostic Program Fiscal Year 2002 Second Quarter Report  

Energy Technology Data Exchange (ETDEWEB)

Since October 2001 the development of the facility diagnostics for NIF has been funded by the NIF Director through the National NIF Diagnostic Program (NNDP). The current emphasis of the NNDP is on diagnostics for the early NIF quad scheduled to be available for experiment commissioning in FY03. During the past six months the NNDP has set in place processes for funding diagnostics, developing requirements for diagnostics, design reviews and monthly status reporting. Those processes are described in an interim management plan for diagnostics (''National NIF Diagnostic Program Interim Plan'', NIF-0081315, April 2002) and a draft Program Execution Plan (''Program Execution Plan for the National NlF Diagnostic Program'', NIF-0072083, October 2001) and ...

2002-04-01

221

Familial unilateral deafness and delayed endolymphatic hydrops  

British Library Electronic Table of Contents (United Kingdom)

Delayed endolymphatic hydrops (DEH) is a unique disorder characterized by fluctuating otologic symptoms in the setting of preexisting unilateral deafness. The symptoms include aural fullness, fluctuating hearing, and/or episodes of vertigo similar to those observed in Meniere disease and may occur ipsilateral or contralateral to the previously deafened ear. In most reported cases, the unilateral deafness has been a profound sensorineural hearing loss with a sudden onset that has been variously attributed to bacterial or viral labyrinthitis, acoustic or cranial trauma, otosclerosis, and congenital CMV infection. Familial occurrence of the syndrome has not previously been reported in the literature. In this report, we describe two possible familial instances of delayed DEH. These patients ra...

2007-01-01

222

Comparison of auditory sense organs in parasitoid Tachinidae (Diptera) hosted by Tettigoniidae (Orthoptera) and homologous structures in a non-hearing Phoridae (Diptera)  

British Library Electronic Table of Contents (United Kingdom)

The dipteran parasitoids Therobia leonidei and Homotrixa alleni (Tachinidae) use acoustic cues to locate their calling tettigoniid (Ensifera, Orthoptera) hosts. The sexually dimorphic tympanal organs of both fly species are located at the prosternum. For comparison a homologous chordotonal organ in the non-hearing fly Phormia regina, Meigen (Phoridae) is also described. The scolopidial sense organs of the ears have approximately 180 sensory cells in Th. leonidei and 250 cells in H. alleni. Interspecific analysis indicates that the cell number and arrangement might be genus specific in Tachinidae. The mononematic scolopidia, each with one sensory cell, are of different sizes and insert at the tympanal membrane. Large scolopidial units (diameter of sensory cells up to 50??m) extend longitudi...

2007-01-01

223

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

Energy Technology Data Exchange (ETDEWEB)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10{sup 6}n/cm{sup 2}-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,{integral}dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. ...

1995-07-01

224

Determination of two-phase flow parameters for nuclear fuel channels using a real-time neutron radiography method  

International Nuclear Information System (INIS)

Multi-dimensional modelling of two-phase flow requires accurate constitutive relationships for interfacial parameters such as interfacial heat transfer, void fraction distribution, interfacial area, etc. However, existing diagnostic systems for measurement of two-phase flow parameters have difficulty measuring two or three-dimensional void distributions required for determination of interfacial parameters. In this work, a Real-Time Neutron Radiography (RTNR) system is developed for non-intrusive measurement of two-phase flow parameters in nuclear fuel channels at low thermal neutron fluxes (on the order of 10"6n/cm"2-s). This advanced radiation technique has the advantage of measuring two-phase flow in 3 1/2 dimensions (x,#integral#dy,t) where the 1/2 dimension refers to an integrated or averaged space dimension. Pipe flow channels, annulus flow channels, MAPLE-type nuclear fuel flow channels, and CANDU-type nuclear fuel flow channels are investigated. Measurements ...

1346-01-01

227

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

228

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting; Die Messung des Dosisflaechenproduktes in der diagnostischen Radiologie als Methode zur Ermittlung der Strahlenexposition. (Ergebnisse, Erfahrungen, Verbesserungsvorschlaege und Empfehlungen zum Strahlenschutz). Bericht ueber ein Expertentreffen  

Energy Technology Data Exchange (ETDEWEB)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...

1995-12-31

229

Validity of Cardiac Markers as Diagnostic and Prognostic Indicators of Complications in Patients undergoing Percutaneous Coronary Intervention  

UK PubMed Central (United Kingdom)

ObjectivesThe aim of this study was to assess the diagnostic and prognostic value of heart-type fatty acid-binding protein (H-FABP) in elective percutaneous coronary intervention...Full Text Available

2010-04-01

230

SNQ for medical research  

Energy Technology Data Exchange (ETDEWEB)

The planned spallation source can be of considerable significance for biomedical basic research and for clinically relevant diagnostic and therapeutic applications. The following gives a brief description and explanations for its possible use in clinical medicine: I. Treatment of Malignant Tumors II. Production of Isotopes for Biochemical Investigations in Living Organisms for Diagnostic Purposes.

1984-12-01

231

Reduction of anti-malarial consumption after rapid diagnostic tests implementation in Dar es Salaam: a before-after and cluster randomized controlled study  

UK PubMed Central (United Kingdom)

BackgroundPresumptive treatment of all febrile patients with anti-malarials leads to massive over-treatment. The aim was to assess the effect of implementing malaria rapid diagnostic...Full Text Available

232

Perceived association between diagnostic and non-diagnostic cues of women's sexual interest: General Recognition Theory predictors of risk for sexual coercion  

UK PubMed Central (United Kingdom)

Young men's errors in sexual perception have been linked to sexual coercion. The current investigation sought to explicate the perceptual and decisional sources of these social perception errors,...Full Text Available

2010-01-01

233

Factors underlying diagnostic delay in tuberculosis patients in a rural area in Tanzania: a qualitative approach  

UK PubMed Central (United Kingdom)

BackgroundDiagnostic delay in patients with tuberculosis (TB) leads to ongoing TB transmission, higher mortality rates and increased patient and government health expenditure. Qualitative...Full Text Available

2010-12-01

234

Diagnostic comparison of malaria infection in peripheral blood, placental blood and placental biopsies in Cameroonian parturient women  

UK PubMed Central (United Kingdom)

BackgroundIn sub-Saharan Africa, Plasmodium falciparum malaria in pregnancy presents an enormous diagnostic challenge. The epidemiological and clinical relevance...Full Text Available

235

Diagnostic Performance of Computed Tomography Colonography in Symptomatic Patients and in Patients with Increased Risk for Colorectal Disease  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate the diagnostic performance (colorectal lesions) of computed tomography (CT) colonography in 111 patients, a majority of whom were at high risk for colorectal neoplasia. Material and Methods: After bowel preparation, CT colonography was performed, immediately followed by conventional colonoscopy. The diagnostic performance of CT colonography was analyzed relative to lesion size, histological diagnosis, and diagnostic certainty. Results: The sensitivity of CT colonography increased with lesion size (P<0.001), and was 91% (21/23) for lesions > or = 10 mm. All 10 carcinomas and 86% (19/22) of adenomas > or = 5 mm were detected. Unconfirmed or false-positive CT findings were generally small and/or reported with low diagnostic certainty. The specificity of CT colonography would be 45% (30/66; 95% CI 34% to 57%) if patients with findings of any size and any ...

2006-11-15

236

Biological, Life Course, and Cross-Cultural Studies All point Toward the Value of Dimensional and Developmental Ratings in the Classification of Psychosis  

UK PubMed Central (United Kingdom)

The diagnostic criteria for schizophrenia in the fourth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-IV1)...Full Text Available

2007-07-01

237

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

238

Age-Stratified Bayesian Analysis To Estimate Sensitivity and Specificity of Four Diagnostic Tests for Detection of Cryptosporidium Oocysts in Neonatal Calves?  

UK PubMed Central (United Kingdom)

There is no gold standard diagnostic test for the detection of bovine cryptosporidiosis. Infection is usually highest in 2-week-old calves, and these calves also excrete high numbers of oocysts. These...Full Text Available

2011-01-01

239

A simple nomogram for sample size for estimating sensitivity and specificity of medical tests  

UK PubMed Central (United Kingdom)

Sensitivity and specificity measure inherent validity of a diagnostic test against a gold standard. Researchers develop new diagnostic methods to reduce the cost, risk, invasiveness, and time. Adequate...Full Text Available

2010-11-01

240

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

243

Plasma diagnostics in the optical and X-ray regions on the plasma focus device PF-4 (TULIP)  

International Nuclear Information System (INIS)

... Union (INTAS), Brussels (Belgium) Science and Technology Center in Unkraine,

2006-09-11

244

Investigating Models of Social Development Using a ...  

Science.gov (United States)

... taker', Adaptive Behavior. In submission. Behavioral Disorders: Diagnostic Criteria for Re- Breazeal (Ferrell), C. (1998), A Motivational System for ...

2011-05-13

245

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei ...

1999-10-01

246

Inflammatory spine disease as a cause of back pain; Entzuendliche Wirbelsaeulenerkrankungen als Ursache fuer Rueckenschmerzen  

Energy Technology Data Exchange (ETDEWEB)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of ...

2006-06-15

247

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density crescent-shaped area at ...

2000-09-01

248

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

249

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

250

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

251

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

252

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

253

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

254

rf-driven ion sources for industrial applications (invited) (abstract)  

Science.gov (United States)

The Plasma and Ion Source Technology Group at the Lawrence Berkeley National Laboratory have been developing rf-driven ion sources for the last two decades. These sources are being used to generate both positive and negative ion beams. Some of these sources are operating in particle accelerators such as the Spallation Neutron Source (SNS) at Oak Ridge, while others are being employed in various industrial ion beam systems. There are four areas where the rf-driven ion sources are commonly used in industry. (1) In semiconductor manufacturing, rf-driven sources have found important applications in plasma etching, ion beam implantation, and ion beam lithography. (2) In material analysis and surface modification, miniature rf-ion sources can be found in focused ion beam systems. They can provide ion beams of essentially any element in the Periodic Table. The newly developed combined rf ion-electron beam unit improves greatly the performance of the secondary ion mass spectrometry tool. (3) ...

2008-02-15

255

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded Surface Display), ...

256

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest study in three main vessel cardiac segments were the main input ...

257

The application of 64 multidetector CT angiography in the evaluation of carotid stenosis and follow-up of carotid endarterectomy and percutaneous transluminal stenting  

International Nuclear Information System (INIS)

Objective: To evaluate the diagnostic value of 64 multidetector-row CT angiography for internal carotid artery (ICA) stenosis and the application in the follow-up of carotid endarterectomy and percutaneous transluminal stenting. Methods: Forty transient ischemic attack (TIA) patients with interpretable CTA and DSA of the cervical carotid arteries were selected from May 2005 to December 2005. This yielded a total of 80 vessels. The CTA curved planar reformations (CPR) and DSA images referenced to the distal cervical internal carotid were graded by two senior neuroradiologists blindly, according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) guidelines. The paired-t test was used to verify the statistical significant difference between pre-operating and post-operating of carotid endarterectomy or percutaneous transluminal stenting in measuring the vascular diameter and area of cross section using CTA. Results: When the ...

2006-09-01

258

Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings  

International Nuclear Information System (INIS)

Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One ...

2008-08-01

259

Lung studies with spiral CT. pitch 1 versus pitch 2; Confronto tra diversi parametri (pitch 1 e 2) nello studio del polmone con Tomografia Computerizzata spirale  

Energy Technology Data Exchange (ETDEWEB)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality. [Italian] Nella Tomografia Computerizzata (TC) spirale il rapporto tra la distanza percorsa dal lettino portapaziente in una rotazione e lo spessore nominale dello strato, entrambi espressi in millimetri, si definische pitch. Se i due valori del rapporto coincidono si avra' pitch uguale a 1, mentre raddoppiando la distanza percorsa dal lettino portapaziente, per il medesimo spessore nominale, conseguentemente raddoppia il pitch (pitch 2). Eseguire gli esami TC spirale utilizzando pitch 2, consente di ridurre la durata dell'esame, la dose ...

1999-03-01

260

High-resolution "1H magnetic resonance spectroscopy imaging at 1.5 and 3 Tesla of the human brain: development of techniques and applications for patients with primary brain tumors and multiple sclerosis  

International Nuclear Information System (INIS)

The aim of this work was to develop several strategies and software-packages for the evaluation of in-vivo-data of the human brain, which were acquired with high-resolution 1H-MRSI at 1.5 and 3 T. Several studies involving phantoms, volunteers and patients were performed. Quality assurance studies were conducted in order to evaluate the reproducibility of the applied MR-techniques at both field strengths. A qualitative comparison-study between MRSI-data from a 1.5 T clinical MR-scanner and a 3 T research MR-scanner showed the advantages of the more advanced MRSI sequences and higher field strength (3 T). A study involving patients with primary brain tumours (gliomas) was performed in cooperation with the Department of Neurosurgery (University of Erlangen-Nuremberg). The methods developed in the course of this study, such as the integration of MRS-data into a stereotactic-system, the segmentation of metabolic maps and the correlation with histopathological findings represent a package ...

261

Diagnostic imaging of Thorotrast associated cholangiocarcinoma and mixed hepatocellular and cholangiocellular carcinoma  

International Nuclear Information System (INIS)

Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to detect againist such an ...

262

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den Okzipitalkondylen, die ...

1995-01-01

263

Comparative accuracy of Computed Tomography and lymphoangiography in detecting lymph node metastases from epithelial cancer of the ovary  

International Nuclear Information System (INIS)

The accuracy is investigated of both lymphangiography and CT in detecting lymph nodes metastases in 59 patients evaluated preoperatively and subsequently submitted to surgery with selective/systemic pelvic and paraaortic lymphadenectomy. CT accuracy was also investigated in 46 patients with a clinically suspected relapse of ovarian cancer (verified by means of clinical and/or CT follow-up in 36 patients, by laparotomy in 7, by fine-needle biopsy in 1 and by necroscopy in the last 2). In the first group (previously untreated patients) the overall results in the pelvis were, respectively, for lymphangiography and CT: 94.9% vs 89.8% accuracy, 86.6% vs 60% sensitivity, 97.7% vs 100% specificity, and 92.8% vs 100%, 95.5% vs 88% positive and negative predictive values. In the paraaortic region the results were: 89.1% vs 86.5% accuracy, 73.3% vs 66.6% sensitivity, 100% specificity for both techniques, 100% positive predictive value, and 84.6% vs 81.5% negative predictive value. In the second ...

1991-01-01

264

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto anziano; nonostante il ...

1999-04-01

265

Binding Affinity of Re(CO)_3 Cl(EPBI) for A#beta#_(_1_#approx#_4_0_) Aggregates and Evaluation of ["9"9Tc"m(CO)_3]"+-EPBI  

International Nuclear Information System (INIS)

The aim of this paper was to develop potential technetium 99m-labeled diagnostic imaging agents specific for the detection of A#beta# plaques. Based on previously obtained A#beta# plaque-specific biphenyls containing a benzimidazol group, "9"9Tc"m and Re-benzimidazol derivatives, ["9"9Tc"m(CO)_3]"+-EPBI and Re(CO)_3 Cl (EPBI), were prepared. The latter showed binding affinities towards A#beta#_(_1_#approx#_4_0_) aggregates in vitro (K_d=13.3 #mu#mol/L) by fluorophotometry. 2-(1-Ethylbenzimidazol-2-yl) pyridine (EPBI) and Re(CO)_3 Cl (EPBI) were synthesized. Binding affinity of Re(CO)_3 Cl (EPBI) for A#beta#_(_1_#approx#__4_0_) aggregates was determined. ["9"9Tc"m(CO)_3]"+-EPBI was prepared and analyzed by HPLC and paper eletrophoresis. Its biodistribution in mice was obtained. The K_d value of Re (CO)_3 Cl (EPBI) is 13.3 #mu#mol/L. Biodistribution of ["9"9Tc"m(CO)_3]"+-EPBI in mice shows brain penetration (0.63 #+-# 0.17) %ID/g (n=3) at 2 min ...

2009-11-01

266

Benign diseases of the mandible in MRI; Benigne Erkrankungen des Unterkiefers im MRT  

Energy Technology Data Exchange (ETDEWEB)

Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und ...

2004-04-01

267

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin ...

2002-05-01

268
270
277

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

278

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

286

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

287

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

1996-11-01

288

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

289

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

290

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

291

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

292

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

293

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

294

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

295

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

296

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

297

Radiation hardening problems of diagnostic components for International Thermonuclear Experimental Reactor (ITER)  

International Nuclear Information System (INIS)

The Joint Work Session of the ITER CDA (Conceptual Design Activities) by four parties, (eg. Japan, USA, USSR and EC), which has continued during 3 years from May 1988 to December 1990 was completed successfully. During the CDA, overall diagnostic systems for the next generation machine was performed for the first time and the principal tasks of Diagnostic research and development (R and D) are identified. In this paper, radiation hardening problems, which should be solved for the period 1991 through 1996 of the ITER EDA (Engineering Design Activities), are described. (author).

298

New developments in the surveillance and diagnostics technology for vibration, structure-borne sound and leakage monitoring systems  

International Nuclear Information System (INIS)

Monitoring and diagnostic systems are of main importance for a safe and efficient operation of nuclear power plants. The author describes new developments with respect to vibration monitoring with a functional extension in the time domain for den secondary circuit, the development of a local system for the surveillance of rotating machines, the structure-borne sound monitoring with improvement of event analysis, esp. the loose part locating, leakage monitoring with a complete system for humidity measurement, and the development of a common platform for all monitoring and diagnostic systems, that allows an efficient access for comparison and cross references.

299

Coherent Synchrotron Radiation as a Diagnostic Tool for the LCLS Longitudinal Feedback System  

Energy Technology Data Exchange (ETDEWEB)

The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL). To ensure the vitality of FEL lasing, a longitudinal feedback system is required together with other diagnostics. In this paper, we study the possibility of using Coherent Synchrotron Radiation (CSR) from the chicane as a diagnostic tool for bunch length feedback. Studies show that CSR is a good candidate, even for a non-Gaussian, double-horn longitudinal charge distribution as in the LCLS. We further check the possibility for detecting possible microbunching.

2005-06-15

300

A somatic dose index for diagnostic radiology  

International Nuclear Information System (INIS)

Irradiation of the human body in diagnostic X-ray procedures results in different absorbed doses in the various body organs. A somatic dose index in formulated by applying the relative sensitivity of the human to each of the most important somatic effects and utilizing the absorbed dose in the affected organs. This quantity is used to convey a cumulative somatic impact and is computed for common radiographic views in diagnostic radiology as a function of beam quality for a nominal IR entrance exposure. Using typical X-ray beam qualities and exposures, the frequency of the various radiographic views that make up an examination and the frequencies of the various examinations in the national population, illustrative examples of the application of the somatic dose index are presented. (author).

1978-01-01

301

Two-year diagnostic stability in early-onset first-episode psychosis  

British Library Electronic Table of Contents (United Kingdom)

Background:- Only one study has used a prospective method to analyze the diagnostic stability of first psychotic episodes in children and adolescents. The Child and Adolescent First-Episode Psychosis Study (CAFEPS) is a 2-year, prospective longitudinal study of early-onset first episodes of psychosis (EO-FEP). Aim:- To describe diagnostic stability and the variables related to diagnostic changes. Methods:- Participants were 83 patients (aged 9-17-years) with an EO-FEP consecutively attended. They were assessed with a structured interview (Kiddie-Schedule for Affective Disorders and Schizophrenia, Present and Lifetime version) and clinical scales at baseline and after 2-years. Results:- The global consistency for all diagnoses was 63.9%. The small group of bipolar disorder had high stabilit...

2011-01-01

302

Targeting a Ruthenium Complex to the Nucleus with Short Peptides  

UK PubMed Central (United Kingdom)

In an effort to develop octahedral metal complexes as chemotherapeutic and diagnostic agents targeted to DNA, it is critical to optimize the properties of their cellular uptake. Appending d-octaarginine...Full Text Available

2010-05-15

303

Studies on the diagnostic accuracy of lymphography  

International Nuclear Information System (INIS)

Contradictory reports in the literature on the reliability of lymphography stimulated the authors to test the diagnostic accuracy, employing methods which are approximately analogous to practice, using carcinoma of the cervix as the model on which the study was carried out. Using 21 observers it was found that there was no correlation between their experience and on-target accuracy of the diagnosis. Good observers obtained an accuracy of 85% with good proportions between sensitivity in the recognition of detail, specificity and readiness to arrive at a decision on the basis of discriminatory ability. With the help of the concept of the ROC curves, the position taken up by the observers in respect of diagnostic decisions, and a complex manner of assessing the various characteristic factors determining diagnostic accuracy, are demonstrated. This form of test, which permits manipulation of different variants of diagnosis, is ...

304

Real-Time Diagnostics for a Reusable Rocket Engine - NASA ...  

Science.gov (United States)

of the Intelligent Control System (ICS) for reusable rocket engines. .... the incoming measurements with corresponding estimates, a sensor failure can be ...

305

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

306

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

1984-01-01

307

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional ...

308

Pubs.GISS: 1977 Publications  

Science.gov (United States)

Astron. J., 82, 890-901, doi:10.1086/112143. Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model....

2011-09-17

309

Microscopic-Observation Drug-Susceptibility Assay for the Diagnosis of TB  

UK PubMed Central (United Kingdom)

BACKGROUNDNew diagnostic tools are urgently needed to interrupt the transmission of tuberculosis and multidrug-resistant tuberculosis. Rapid,...Full Text Available

2006-10-12

310

Humoral BMP-2 is Sufficient for Inducing Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

Microcalcifications are an important diagnostic marker for breast cancer on mammograms, yet the mechanism of their formation is poorly understood. Indeed, there is presently no short-latency,...Full Text Available

2008-01-01

311

Diagnostics of Radionuclides Effects Results  

International Science & Technology Center (ISTC)

Development of New Methods and Means of Assessing of Consequences of Radionuclide and Heavy Metal Salt Effect, Criteria of Forecasting Physiological State and Productivity of the Farm Animals under Conditions of Ecological Pollution of Environment

312

Diagnostic Value of C-reactive Protein in Complicated Appendicitis  

UK PubMed Central (United Kingdom)

PurposeEarly detection of appendicitis has increased due to development of computed tomography and ultrasonography, yet we are frequently meeting complicated appendicitis, including...Full Text Available

2011-06-01

314

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

315

Cardiac Enzymes, Renal Failure and Renal Transplantation  

UK PubMed Central (United Kingdom)

Diagnostic accuracy of the currently available serum markers of cardiac injury, such as myoglobin, creatine kinase and its myocardial isoform, are altered in patients with renal failure. It is shown...Full Text Available

2006-03-01

316

Anxiety and Cancer Treatment: Response to Stressful Radiotherapy  

UK PubMed Central (United Kingdom)

Previous research with individuals undergoing surgery or diagnostic procedures provided a conceptual framework for analysis of radiation therapy, a common form of cancer treatment. The present...Full Text Available

1984-01-01

317

A Dose- and Time-Controllable Syngeneic Animal Model of Breast Cancer Microcalcification  

UK PubMed Central (United Kingdom)

IntroductionThe development of novel diagnostic agents for the detection of breast cancer microcalcifications requires a reliable animal model. Based on previous...Full Text Available

2010-07-01

318

Metallic implants and exposure to radiofrequency radiation  

International Nuclear Information System (INIS)

There is increasing use of radiofrequency radiation (RFR) in industry for communications, welding, security, radio, medicine, navigation etc. It has been recognised for some years that RFR may interact with cardiac pacemakers and steps have been taken to prevent this interference. It is less well recognised that other metallic implants may also act as antennas in an RFR field and possibly cause adverse health effects by heating local tissues. There are a large and increasing number of implants having metal components which may be found in RFR workers. These implants include artificial joints, rods and plates used in orthopaedics, rings in heart valves, wires in sutures, bionic ears, subcutaneous infusion systems and (external) transdermal drug delivery patches"1. The physician concerned with job placement of such persons requires information on the likelihood of an implant interacting with RFR so as to impair health. The following outlines the approach developed in ...

319

Heavy metal concentrations in plants and different harvestable parts: A soil-plant equilibrium model  

International Nuclear Information System (INIS)

A mathematical interaction model, validated by experimental results, was developed to modeling the metal uptake by plants and induced growth decrease, by knowing metal in soils. The model relates the dynamics of the uptake of metals from soil to plants. Also, two types of relationships are tested: total and available metal content. The model successfully fitted the experimental data and made it possible to predict the threshold values of total mortality with a satisfactory approach. Data are taken from soils treated with Cd and Ni for ryegrass (Lolium perenne, L.) and oats (Avena sativa L.), respectively. Concentrations are measured in the aboveground biomass of plants. In the latter case, the concentration of metals in different parts of the plants (tillering, shooting and earing) is also modeled. At low concentrations, the effects of metals are moderate, and the dynamics appear to be linear. However, increasing concentrations show nonlinear behaviors. - The model ...

2010-08-01

320

Comparison of NH_4"+-N and NO_3"--N nutrition in hybrid and conventional rice at the late growth stage  

International Nuclear Information System (INIS)

The difference of NH_4"+-N/NO_3"--N nutrition between hybrid and conventional rice varieties at the late growth stage was studied by using "1"5N-tracer technique. The results showed that the nitrate fertilizer utilization efficiency by the hybrid rice after anthesis was 7.8% higher than that by the ordinary rice variety, and the nitrate fertilizer recovery fraction by the former was 13.2% greater than that by the latter. The varietal difference in NO_3"--N uptake and utilization was almost twice as that in NH_4"+-N. It was also showed that "1"5N distribution in ear of the hybrid rice was about 20% greater than that of the conventional variety, but there were no obvious differences between NO_3"--N and NH_4"+-N. However, "1"5N distribution in the lower node leaves and root was found to be significant higher with NO_3"--N than that with NH_4"+-N in both rice varieties, particularly in the hybrid rice. Compared with NH_4"+-N, NO_3"--N top-dressing before anthesis was ...

321

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

322

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

323

Diagnostic value of apparent diffusion coefficient value in prediction of grade for neuroepithelial tumors  

International Nuclear Information System (INIS)

Objective: To investigate the predictive value of ADC value in grading of neuroepithelial tumors. Methods: The clinical data and images of 70 patients with neuroepithelial tumors pathologically proven were collected and analyzed retrospectively. All the patients were classified into low (WHO I or II) and high (WHO III or IV) grade groups which included 40 and 30 cases respectively according to the 2007 WHO classification of tumours of the central nervous system. All the patients underwent plain and contrast-enhanced MR scan and DWI before surgery. The minimum ADC (MinADC) value was measured postoperatively on ADC maps. The Ki-67 labeling index (Ki-67 LI) of tumor tissue was determined by immunohistochemistry. MinADC values for two groups were analyzed using student t test, while the age and Ki-67 LI for the two groups was analyzed using Mann-Whitney test (P<0.05 considered to be significant). Also the MinADC value and Ki-67 LI were analyzed with Pearson ...

2009-11-01

324

CT-guided injection for ganglion impar blockade: a radiological approach to the management of coccydynia  

International Nuclear Information System (INIS)

Aim: To evaluate the role of computed tomography (CT) in needle placement for ganglion impar blocks, and to determine the efficacy of CT-guided ganglion impar blocks in the management of coccydynia. Materials and methods: The results of ganglion impar blockade in eight patients with coccydynia secondary to trauma or unknown cause were reviewed. The diagnosis of coccydynia was based on clinical history, location of pain, and response to previous diagnostic and therapeutic procedures. The eight patients were treated with CT-guided ganglion impar blocks to manage their coccyx pain after conservative procedures, including oral medication and cushions, failed to provide relief. All patients were subjected to ganglion impar blocks under a thin-section CT-guided technique for needle placement, using a mixture of bupivacaine and triamcinolone. The patients were followed-up for a period of 6-months. Results: Eight patients were treated in this study with a total of 11 ...

2010-01-01

325

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

326

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub ...

2000-05-01

327

Trial of using computer tomography in the diagnosis of mediastinal diseases in children  

Energy Technology Data Exchange (ETDEWEB)

In 15 children (in age 2 weeks - 15 years) the computer tomography beside radiological examination was done because of mediastinal diseases. In all cases the computer tomography was valuable. In 4 cases obtained results have changed diagnostic conclusions. The examples are described showing the usefulness of the computer tomography as supplementary diagnostic method in mediastinal diseases in children.

1981-01-01

328

Survey of radiation doses to patients from the diagnostic use of X-rays  

International Nuclear Information System (INIS)

The National Radiological Protection Board is to carry out a survey of doses received by patients from the diagnostic use of X-rays, beginning in June 1977, and carried out at over 100 National Health Service hospitals. Details are given of the reasons for carrying out the survey and the survey objectives. The survey working methods are discussed, together with methods of calculation of the genetically significant dose. The radiation doses will be measured by a thermoluminescent dosimeter developed specially for the survey. (U.K.).

1977-06-01

329

Spreader Design for FERMI@Elettra Free Electron Laser  

Energy Technology Data Exchange (ETDEWEB)

In this note we describe a conceptual design of a part ofthe electron beam delivery system for FERMI@Elettra free electron laser(FEL) located between the end of the linac and the entrance to the FEL.This part includes the emittance diagnostic section, the electron beamswitchyard for two FELs called spreader and matching sections. The designmeets various constrains imposed by the existing and planned buildingboundaries, desire for utilization of existing equipment and demands forvarious diagnostic instruments.

2007-01-18

330

Researches on gear fault diagnostic techniques  

Science.gov (United States)

Attention is given to recent research on gear fault diagnostic techniques. A mathematic model for vibration signals of defective gears is presented. Novel methods of gear fault diagnosis, such as zoom complex envelope analysis, wideband demodulation techniques, bispectrum analysis, correlation spectrum analysis, and maximum entropy spectrum analysis, are demonstrated. The wide-band demodulation technique is found to exhibit a high SNR. Bispectrum and correlation spectrum are excellent for some mechanical fault forms.

1992-10-01

331

Process in Plasma Research at IPJ and IPPLM, POLAND  

International Nuclear Information System (INIS)

The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.

2006-01-01

332

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

333

Evaluation of two-beam spectroscopy as a plasma diagnostic  

Energy Technology Data Exchange (ETDEWEB)

A two-beam spectroscopy (TBS) system is evaluated theoretically and experimentally. This new spectroscopic technique uses correlations between components of emitted light separated by a small difference in angle of propagation. It is thus a non-perturbing plasma diagnostic which is shown to provide local (as opposed to line-of-sight averaged) information about fluctuations in the density of light sources within a plasma - information not obtainable by the usual spectroscopic methods. The present design is an improvement on earlier systems proposed in a thesis by Rostler.

1980-04-01

334

Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.  

UK PubMed Central (United Kingdom)

Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol...Full Text Available

1995-11-01

335

Electron beam and high-speed optical diagnostics for the Los Alamos HIBAF (High Brightness Accelerator FEL) Facility  

Energy Technology Data Exchange (ETDEWEB)

Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.

1989-01-01

336

DIPAC 2005 7. European workshop on beam diagnostics and instrumentation for particle accelerators  

Energy Technology Data Exchange (ETDEWEB)

Accelerators can not be improved without the development of adequate beam instruments and diagnostic tools. This year this statement is particularly right: a lot of contributions are dedicated to beam monitoring and to the design of new beam monitors based on original technologies. This document gathers about 100 contributions.

2005-07-01

337

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

338

Baryon-strangeness correlations: a diagnostic of stronglyinteracting matter  

Energy Technology Data Exchange (ETDEWEB)

The correlation between baryon number and strangeness elucidates the nature of strongly interacting matter. This diagnostic can be extracted theoretically from lattice QCD calculations and experimentally from event-by-event fluctuations. The analysis of present lattice results above the critical temperature severely limits the presence of q{bar q} bound states, thus supporting a picture of independent (quasi)quarks. Details may be found in [1].

2005-10-07

339

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

340

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

341

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

342

CT-guided percutaneous core biopsies of pulmonary lesions: Diagnostic accuracy, complications and therapeutic impact  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. Material and methods: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. Results: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis ...

2001-03-01

343

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

344

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

345

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

346

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

347

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

348

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

349

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

350

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

351

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

352

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

353

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

354

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

355

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

356

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

357

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

358

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

359

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

360

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

361

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

362

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

363

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

364

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

365

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

366

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

367

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

368

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

369

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

370

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

371

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

372

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

373

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. Besides an ...

2006-11-13

374

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

375

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...

2001-01-01

376

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

377

The electron cyclotron absorption diagnostic for the JET pumped divertor plasma  

International Nuclear Information System (INIS)

We present the design of a diagnostic system to measure electron cyclotron absorption at the second harmonic E-mode resonance in the JET pumped divertor plasma. The diagnostic will measure transmission as a function of frequency along one or more sightlines from which the spatial profile of the n_eT_e product will be deduced. The divertor is briefly described, and the electron cyclotron resonance physics relevant to this measurement is reviewed. The problems of measuring transmission using an oversized transmission system are discussed and the chosen measurement technique, a swept frequency interferometer using a coherent radiation source, is described. A prototype of the instrument has been assembled to test the measurement technique. Some data demonstrating the instrument's characteristics are presented. The nonresonant losses, which may affect the interpretation of the measurement, are also discussed. (orig.).

1993-03-01

378

Visible Earth: Typhoon Aere  

Science.gov (United States)

NASA's Visible Earth catalog of NASA images and animations of our home planet.

381

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

389

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

391

Lead-203 for skeletal imaging  

International Nuclear Information System (INIS)

... biological variability body distribution kidneys labelled compounds lead 203

392

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

394

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

402

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

405

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

416

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

418

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

419

Utilization of fractional Brownian motion in constrained least-squares restoration of medical images  

International Nuclear Information System (INIS)

Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.

420

Document image retrieval with morphology-based segmentation and features combination  

Science.gov (United States)

Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...

2011-01-01

421

Comparative evaluation of /sup 99m/Tc GH, /sup 99m/TcO_4, and /sup 99m/Tc DTPA as brain imaging agents  

International Nuclear Information System (INIS)

The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.

422

Traumatic extremity arterial injury in children: Epidemiology, diagnostics, treatment and prognostic value of Mangled Extremity Severity Score  

UK PubMed Central (United Kingdom)

BackgroundTraumatic paediatric arterial injuries are a great challenge due to low incidence and specific characteristics of paediatric anatomy and physiology. The aim of the present...Full Text Available

423

The treatment of mycosis fungoides and related conditions with particular emphasis on electron therapy.  

UK PubMed Central (United Kingdom)

The difficulties created by the lack of generally accepted views on classification, diagnostic criteria and natural history of the cutaneous lymphomata are discussed. Only the lymphomata which remain...Full Text Available

1975-03-01

424

The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens  

UK PubMed Central (United Kingdom)

BackgroundPCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella...Full Text Available

425

The concept of mental disorder: diagnostic implications of the harmful dysfunction analysis  

UK PubMed Central (United Kingdom)

What do we mean when we say that a mental condition is a medical disorder rather than a normal form of human suffering or a problem in living? The status of psychiatry as a medical discipline depends...Full Text Available

2007-10-01

426

The Effect of Age on the Gingival Crevicular Fluid Composition During Experimental Gingivitis. A Pilot Study  

UK PubMed Central (United Kingdom)

Background:Cytokines have been proposed as potentially useful diagnostic or prognostic markers of periodontal inflammation related alterations during the experimental gingivitis...Full Text Available

427

Stability of Trichomonas vaginalis DNA in Urine Specimens?  

UK PubMed Central (United Kingdom)

Trichomonas vaginalis is an important pathogen in both men and women. Culture is considered the diagnostic gold standard, although studies have shown that PCR is more sensitive than...Full Text Available

2008-05-01

428

Serum hepcidin as a diagnostic test of iron deficiency in premenopausal female blood donors  

UK PubMed Central (United Kingdom)

BackgroundCurrently used indicators of iron status have limitations. Hepcidin, a key regulator of iron metabolism, is reduced in iron deficiency. We sought to determine the properties...Full Text Available

2011-08-01

429

Rome III: The functional gastrointestinal disorders, third edition, 2006  

UK PubMed Central (United Kingdom)

Functional gastrointestinal disorders (FGIDs) represent a common and important class of disorders within gastroenterology. RomeI, the first edition was published in 1994, with symptom-based diagnostic...Full Text Available

2008-04-07

430

Reduced PCR Sensitivity Due to Impaired DNA Recovery with the MagNA Pure LC Total Nucleic Acid Isolation Kit  

UK PubMed Central (United Kingdom)

The increasing demand for molecular diagnostics in clinical microbiology laboratories necessitates automated sample processing. In the present study, we evaluated the performance of the MagNA Pure LC...Full Text Available

2005-09-01

431

Real-time system for processing regime diagnostic on accelerator  

International Nuclear Information System (INIS)

The automatic real-time system operating at the LU-10 linac and providing measurements of the parameters such as the beam current (average and pulse values), the electron energy, the linear density distribution of beam current, and also the conveyor speed is described in the paper.

432

Pubs.GISS: Ghil et al. 1977: A balanced ... - Publications - NASA  

Science.gov (United States)

Ghil, M., B. Shkoller, and V. Yangarber, 1977: A balanced diagnostic system compatible with a barotropic prognostic model. M. Weather. Rev. , 105, 1223- 1238, ...

433

Prenatal diagnosis for recessive dystrophic epidermolysis bullosa in 10 families by mutation and haplotype analysis in the type VII collagen gene (COL7A1).  

UK PubMed Central (United Kingdom)

BACKGROUND: Epidermolysis bullosa (EB) is a group of heritable diseases that manifest as blistering and erosions of the skin and mucous membranes. In the dystrophic forms of EB (DEB), the diagnostic...Full Text Available

1996-01-01

434

Performance and usefulness of the Hexagon rapid diagnostic test in children with asymptomatic malaria living in the Mount Cameroon region  

UK PubMed Central (United Kingdom)

BackgroundRapid and correct diagnosis of malaria is considered an important strategy in the control of the disease. However, it remains to be determined how well these tests can...Full Text Available

435

PROGRESS AND PROBLEMS IN THE APPLICATION OF FOCUSED ULTRASOUND FOR BLOOD-BRAIN BARRIER DISRUPTION  

UK PubMed Central (United Kingdom)

Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the...Full Text Available

2008-08-01

436

Optical and Structural Characteristics of Heavily Boron-Implanted CdTe.  

Science.gov (United States)

Cadmium telluride single crystals were subjected to multiple-energy boron ion implants with total doses up to 1.5 x 10 sq cm. Various diagnostic techniques were used to assess the structural and electronic properties of these crystals in their as-implante...

1988-01-01

437

Nuclear ? catenin as a potential prognostic and diagnostic marker in patients with colorectal cancer from Hong Kong  

UK PubMed Central (United Kingdom)

Aims: To study the expression of nuclear β catenin in patients with colorectal cancer, colorectal adenoma, and colorectal polyps to elucidate its role in carcinogenesis, and its...Full Text Available

2003-12-01

438

Multiplexed, rapid detection of H5N1 using a PCR-free nanoparticle-based genomic microarray assay  

UK PubMed Central (United Kingdom)

BackgroundFor more than a decade there has been increasing interest in the use of nanotechnology and microarray platforms for diagnostic applications. In this report, we describe...Full Text Available

439

Monitoring potential neurotoxic effects of hazardous waste disposal  

UK PubMed Central (United Kingdom)

This report reviews neurotoxicological principles relevant to situations of hazardous waste disposal. Some of the diagnostic techniques currently used for field assessment of nervous system dysfunction...Full Text Available

1983-02-01

440

Investigation of Dyslexia and SLI Risk Variants in Reading- and Language-Impaired Subjects  

UK PubMed Central (United Kingdom)

Dyslexia (or reading disability) and specific language impairment (or SLI) are common childhood disorders that show considerable co-morbidity and diagnostic overlaps and have been suggested to share...Full Text Available

2011-01-01

441

Impalpable Testis and Laparoscopy: When the Gonad Is Not Visualized  

UK PubMed Central (United Kingdom)

The diagnostic accuracy of laparoscopy for impalpable testis is well recognized. However, in some cases, laparoscopic findings may be misleading, and a viable gonad may be missed with significant medico-legal...Full Text Available

2004-01-01

442

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both inside and outside the TFTR shield walls. It ...

443

Identification of Cardiac Myosin-binding Protein C as a Candidate Biomarker of Myocardial Infarction by Proteomics Analysis*  

UK PubMed Central (United Kingdom)

Acute myocardial infarction (AMI) is a common cause of death for which effective treatments are available provided that diagnosis is rapid. The current diagnostic gold standards are circulating cardiac...Full Text Available

2009-12-01

444

IGENPRO knowledge-based digital system for process transient diagnostics and management  

Energy Technology Data Exchange (ETDEWEB)

Verification and validation issues have been perceived as important factors in the large scale deployment of knowledge-based digital systems for plant transient diagnostics and management. Research and development (R&D) is being performed on the IGENPRO package to resolve knowledge base issues. The IGENPRO approach is to structure the knowledge bases on generic thermal-hydraulic (T-H) first principles and not use the conventional event-basis structure. This allows for generic comprehensive knowledge, relatively small knowledge bases and above all the possibility of T-H system/plant independence. To demonstrate concept feasibility the knowledge structure has been implemented in the diagnostic module PRODIAG. Promising laboratory testing results have been obtained using data from the full scope Braidwood PWR operator training simulator. This knowledge structure is now being implemented in the transient management module PROMANA to treat ...

1997-12-31

445

How Missing Information in Diagnosis Can Lead to Disparities in the Clinical Encounter  

UK PubMed Central (United Kingdom)

Previous studies have documented diagnostic bias and noted that its reduction could eliminate misdiagnosis and improve mental health service delivery. Few studies have investigated clinicians'...Full Text Available

2008-11-01

446

Gonorrhoea in men: clinical and diagnostic aspects.  

UK PubMed Central (United Kingdom)

AIM: To review the features of gonococcal infection in men in the 1990s. METHODS: A retrospective study of all men with gonorrhoea presenting to an inner city department of genitourinary medicine in...Full Text Available

1996-12-01

447

Genetic screening: The vista of genomic medicine  

UK PubMed Central (United Kingdom)

The accelerating development of biochemical and DNA-based diagnostic tests for human genetic conditions in the last decade has engendered a revolution in genetic diagnosis. Both genetic testing and...Full Text Available

2011-01-01

448

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

449

Fetal, perinatal, and infant death with congenital renal anomaly  

UK PubMed Central (United Kingdom)

Aims: To ascertain why 19.6% of pregnancies in which a fetal renal anomaly has been detected fail to produce a surviving child, and whether antenatal diagnostic accuracy has altered since...Full Text Available

2002-08-01

450

Fetal ascites: an unusual presentation of Niemann-Pick disease type C.  

UK PubMed Central (United Kingdom)

Two infants were seen with severe ascites detected before birth, a previously unreported presentation of Niemann-Pick disease type C. In the second infant no diagnostic storage cells were present in...Full Text Available

1989-10-01

451

Evaluation of the OptiMAL Test for Rapid Diagnosis of Plasmodium vivax and Plasmodium falciparum Malaria  

UK PubMed Central (United Kingdom)

The development of rapid and specific diagnostic tests to identify individuals infected with malaria is of paramount importance in efforts to control the severe public health impact of this disease....Full Text Available

1998-01-01

452

Evaluation of a diagnostic algorithm for heart disease in neonates.  

UK PubMed Central (United Kingdom)

OBJECTIVE--To develop, test, and validate an algorithm for diagnosing disease in neonates during an over the telephone referral to a specialist cardiac centre. DESIGN--A draft algorithm requiring only...Full Text Available

1991-04-20

453

Electrostatic probe vacuum system for TCA BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)

1999-12-01

454

Diagnostics of Gun Barrel Propellants.  

Science.gov (United States)

Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...

1983-11-01

455

Diagnostic Dilemma in an Unusual Case of Common Bile Duct Obstruction  

UK PubMed Central (United Kingdom)

Biliary obstructions are rarely caused by a foreign body and have received sparse attention. We present an unusual case with pruritis and abdominal pain caused by impacted full length surgical gauze...Full Text Available

2011-06-01

456

Development and Application of Pathovar-Specific Monoclonal Antibodies That Recognize the Lipopolysaccharide O Antigen and the Type IV Fimbriae of Xanthomonas hyacinthi  

UK PubMed Central (United Kingdom)

The objective of this study was to develop a specific immunological diagnostic assay for yellow disease in hyacinths, using monoclonal antibodies (MAbs). Mice were immunized with a crude cell wall preparation...Full Text Available

1999-09-01

457

Decreased CSF Transferrin in sCJD: A Potential Pre-Mortem Diagnostic Test for Prion Disorders  

UK PubMed Central (United Kingdom)

Sporadic Creutzfeldt-Jakob-disease (sCJD) is a fatal neurodegenerative condition that escapes detection until autopsy. Recently, brain iron dyshomeostasis accompanied by increased transferrin (Tf) was...Full Text Available

458

Comparing the Diagnostic Performance of 2 Clinical Decision Rules to Rule Out Deep Vein Thrombosis in Primary Care Patients  

UK PubMed Central (United Kingdom)

PURPOSE The Wells rule is widely used for clinical assessment of patients with suspected deep vein thrombosis (DVT), especially in the secondary care setting. Recently a new clinical decision...Full Text Available

2011-01-01

459

Colonic polyps: inheritance, susceptibility, risk evaluation, and diagnostic management  

UK PubMed Central (United Kingdom)

Colorectal cancer (CRC) is the third-ranked neoplasm in order of incidence and mortality, worldwide, and the second cause of cancer death in industrialized countries. One of the most important environmental...Full Text Available

460

Clinical value of SPECT/CT for evaluation of patients with painful knees after total knee arthroplasty- a new dimension of diagnostics?  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of our study was to evaluate the clinical value of hybrid SPECT/CT for the assessment of patients with painful total knee arthroplasty (TKA).MethodsTwenty-three...Full Text Available

461

Clinical efficacy of the use of information technology in cardiology: initial results of angiographic teleconsultation in the Netherlands  

UK PubMed Central (United Kingdom)

Background With the increasing use of cineless diagnostic angiography laboratories, modern telecommunication networks provide an excellent opportunity to transfer dynamic cardiac...Full Text Available

2001-12-01

462

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

463

Blood conservation strategies to reduce the need for red blood cell transfusion in critically ill patients  

UK PubMed Central (United Kingdom)

Anemia commonly affects critically ill patients. The causes are multifactorial and include acute blood loss, blood loss from diagnostic testing and blunted red blood cell production. Blood transfusions...Full Text Available

2008-01-01

464

Bilateral Pneumothorax and Subcutaneous Emphysema following Endoscopic Retrograde Cholangiopancreatography: A Rare Complication  

UK PubMed Central (United Kingdom)

Endoscopic Retrograde Cholangiopancreatography (ERCP) is a widely used diagnostic and therapeutic modality in the management of biliary and pancreatic disease. Some of the complications of the procedure,...Full Text Available

2010-01-01

465

Anti-albumin antibodies in chronic liver diseases: diagnostic significance of these antibodies in patients with conventional or immunosuppressive therapy.  

UK PubMed Central (United Kingdom)

The two categories of anti-albumin antibodies (AAA), namely precipitins (AA-P) and agglutinins (AA-Aggl), were investigated in 260 patients with morphologically diagnosed chronic liver diseases (CLD)....Full Text Available

1981-02-01

466

An evaluation of cerebrospinal fluid oligoclonal banding confirmed by immunofixation on agarose gel.  

UK PubMed Central (United Kingdom)

The cerebrospinal fluid (CSF) from 115 consecutive patients undergoing diagnostic lumbar puncture or myelography was examined to determine the usefulness of immunofixation, following agarose gel electrophoresis,...Full Text Available

1983-06-01

467

Affinity maturation of human botulinum neurotoxin antibodies by light chain shuffling via yeast mating  

UK PubMed Central (United Kingdom)

Botulism is caused by the botulinum neurotoxins (BoNTs), the most poisonous substance known. Because of the high potency of BoNT, development of diagnostic and therapeutic antibodies for botulism requires...Full Text Available

2010-04-01

468

Advances in cancer tissue microarray technology: Towards improved understanding and diagnostics  

UK PubMed Central (United Kingdom)

Over the past few years, tissue microarray (TMA) technology has been established as a standard method for assessing the expression of proteins or genes across large sets of tissue specimens....Full Text Available

2006-03-30

469

Advances in Fine Needle Aspiration Cytology for the Diagnosis of Pulmonary Carcinoma  

UK PubMed Central (United Kingdom)

New developments in the field of thoracic oncology have challenged the way pathologists approach the diagnosis of pulmonary carcinoma. Nonsmall cell carcinoma is no longer an adequate diagnostic category....Full Text Available

470

Accuracy of electrocardiographic and echocardiographic indices in predicting life threatening ventricular arrhythmias in patients operated for tetralogy of Fallot  

UK PubMed Central (United Kingdom)

OBJECTIVE—To validate the accuracy of the prognostic significance of non-invasive clinical diagnostic indices as predictors of sustained ventricular tachycardia (sVT) or fibrillation...Full Text Available

1999-06-01

471

A survey on clinical presentation and nutritional status of infants with suspected cow' milk allergy  

UK PubMed Central (United Kingdom)

BackgroundCow's milk is the most common food allergen in infants and the diagnosis of cow's milk allergy is difficult, even with the use of several diagnostic tests. Therefore, elimination...Full Text Available

472

A diagnostic survey of infants referred for chromosome analysis in the neonatal period.  

UK PubMed Central (United Kingdom)

Examination and assessment of 140 liveborn and stillborn infants referred within two weeks of birth for chromosome analysis showed that 48 had Down's syndrome, 12 other chromosome abnormalities, 17...Full Text Available

1980-10-18

473

Thomson scattering: a powerful diagnostic tool of plasma physics  

International Nuclear Information System (INIS)

Thomson scattering is the process in which a low-energy photon scatters from a free electron. When a laser pulse propagates through a plasma, the spectrum of the scattered light due to the Thomson scattering is proportional to the power spectrum of the electron density fluctuations, i.e., dynamic form factor, from which various plasma parameters can be inferred, such as electron temperature and plasma flow velocity. After years of development. Thomson scattering has now become a powerful diagnostic tool of plasma physics. (authors)

2008-08-01

474

Somatic radiation risk in X-ray diagnostics  

Energy Technology Data Exchange (ETDEWEB)

The authors give a survey of the somatic radiation risk in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk.

1983-12-01

475

Somatic radiation risk in X-ray diagnostics  

International Nuclear Information System (INIS)

The authors give a survey of the somatic radiation ris in X-ray diagnostics. A somatic dose index is calculated for different examination methods containing the organ doses to the red bone marrow, the lung, the female breast, and the thyroid gland and evaluating their somatic significance. If this somatic dose index by which the individual radiation risk is described, is multiplied by the examination frequencies per year in the German Federal Republic, one gets the somatically significant dose index, which is a measure of the collective somatic radiation risk. In this sense, mammography has the highest, and dental radiography the lowest collective radiation risk. (orig.).

1983-01-01

476

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

477

Radiation risk in diagnostic radiology  

International Nuclear Information System (INIS)

An attempt was made to quantify the radiation risk of diagnostic radiology. After a general introduction of terms as radiation damage, radiation risk and effective dose equivalent, based on publications of the ICRP, somatic dose indexes were computed for several radiologic investigations, that comprise organ doses committed to red bone marrow, lung, female breast and thyroid with and without considering the rest of the body. The dose for the rest of the body was assumed to be equal to the dose received by the red bone marrow, that is also distributed over the whole body. Neglecting the exposure of the rest of the body resulted in an insignificant increase in the estimated somatic risk, with its experimental determination not being necessary. (author).

1984-01-01

478

Post-transplant monitoring of renal allografts: are we there yet?  

British Library Electronic Table of Contents (United Kingdom)

Transplantation has emerged as the therapy of choice for many patients with end organ failure. One of the major goals is to tailor immunosuppressive therapy to the individual needs of every patient to balance the risk for rejection and over-immunosuppression. This will require diagnostic tools that can detect harmful processes in the allograft early, and that can be measured repeatedly. This review will consider recent advances in our understanding of the molecular nature of these processes and how this information is being utilized to design novel diagnostic assays to non-invasively monitor allografts. Highlighted is the need for large-scale prospective multi-centre studies to validate assays that show early promise in single centre studies.

2009-01-01

479

NuMI proton beam diagnostics and control: achieving 2 megawatt capability  

Energy Technology Data Exchange (ETDEWEB)

The NuMI proton beam at Fermilab currently delivers 120 GeV protons to the neutrino production target with design beam power capability to 400 kW. Upgrade capability to 700 kW is being prepared, with planning toward delivering 2.3 MW beam provided by the Project X accelerator upgrade plan. We report on the system of beam diagnostics and control used in operation of the NuMI beam. Also considered are the steps to provide a robust system for transport and targeting beam of 2 MW and beyond.

2008-10-01

480

GPLS VME MODULE: A DIAGNOSTIC AND DISPLAY TOOL FOR NSLS MICRO SYSTEMS.  

Energy Technology Data Exchange (ETDEWEB)

The General Purpose Light Source VME module is an integral part of every front-end micro in the NSLS control system. The board incorporates features such as a video character generator, clock signals, time-of-day clock, a VME bus interrupter and general-purpose digital inputs and outputs. This module serves as a valuable diagnostic and real-time display tool for the micro development as well as for the final operational systems. This paper describes the functions provided by the board for the NSLS micro control monitor software.

1999-03-29

481

Electron temperature diagnostics in the RFX reversed field pinch experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an integrated approach to the problem of electron temperature diagnostics of the plasma in a reversed field pinch. Three different methods, sampling different portions of the electron distribution function, are adopted, namely Thomson scattering, soft X-ray spectroscopy by pulse-height analysis and filtered soft X-ray intensity ratio. A careful analysis of the different sources of systematic errors is performed and a novel statistical approach is adopted to mutually validate the three independent measurements. A satisfactory agreement is obtained over a large range of experimental conditions, indicating that in the plasma core the energy distribution function is well represented by a maxwellian. (author)

2000-08-01

482

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

483

Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia  

International Nuclear Information System (INIS)

Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.

484

Performance of Brazilian thermoluminescent CaSO{sub 4}: Dy pellets in standard diagnostic radiology beams  

Energy Technology Data Exchange (ETDEWEB)

The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in ...

2006-07-01

485

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due to false-positive ...

1997-09-01

486

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...

1982-06-01

487

Primary study on lesion mimic mutants of rice (oryza sativa L.)  

International Nuclear Information System (INIS)

Nineteen lesion mimic mutants (xsl1-19) of japonica rice Xiushui11 were obtained by ?-rays irradiation treatment. All mutants belonged to whole life lesion mimic. Lesion mimic of mutants didn't largen after tillering stage, leaves didn't wither, and no effect on the plants exsert spikes and seed. When the highest temperature in day exceeded 32 degree C in seedling stage, lesion mimic of all mutant expect xsl19 disappeared. Under 32 degree C, lesion mimic would appear gradually, and symptoms weren't inhibited by high temperature after 5 leaf stage. The plant heights of all lesion mimic mutants were 47.56-63.54 cm in the tillering stage, and that of CK was 83.75 cm; but the dwarf phenomenon of mutants only appeared before tillering stage, and didn't affect plant heights finally; the heading dates of mutants were the same to the CK, the ear length of all mutants were 9.43-15.19 cm, and that of CK was 16.41 cm; the total grain quantity per spike of all mutants were ...

2007-08-01

488

Less waste corn, more land in soybeans, and the switch to genetically modified crops: trends with important implications to wildlife management  

Science.gov (United States)

An abundance of waste corn, a key food of many wildlife species, has helped make possible the widespread success of wildlife management in the United States over the past half century. We found waste corn post harvest in Nebraska declined by 47% from 1978 to 1998 due primarily to improvements in combine headers resulting in a marked decline in ear loss. The reduction in waste coincided with major declines in fat storage by sandhill cranes and white-fronted geese during spring migration. Sandhill cranes, northern pintails, white-fronted geese, and lesser snow geese avoided soybeans while staging in spring in the Rainwater Basin Area and Central Platte River Valley. These findings and other literature suggest soybeans are a marginal food for wildlife particularly during periods of high energy requirements. Soybean acreage has increased by 600% in the United States since 1950 and now comprises nearly one-quarter of the nation>'s cropland. With over 80% of the ...

2004-01-01

489

Granitoid formation is ineffective in isotopically homogenizing continental crust: Evidence from archean rocks of the Wind River Mountains, Wyoming  

Energy Technology Data Exchange (ETDEWEB)

The Archean core of the Laramide Wind River uplift records evidence of at least three major granitoid-forming episodes. The oldest, the Dry Creek gneiss (DCG), was emplaced by 2.8 Ga and occupies the northeastern part of the range. Mafic, pelitic and ultramafic inclusions occur in the DCG. Elsewhere in the Wind River Mountains there is evidence for crustal components as old as 3.8 Ga. The Bridger batholith (BB), intruded at 2.67 Ga, is found in the west-central Wind River Mountains. The Wind River batholith (WRB) refers to the youngest Late Archean granodiorites and granites which are found throughout the range and includes granitoids previously name the Louis Lake, Bears Ears, Popo Agie, and Middle Mountain intrusions. Although granitoids of the Wind River batholith have been dated at 2.63 and 2.55 Ga, they are considered together here because there is a complete gradation in rock type and because definite intrusive contacts are scarce. The DCG, BB, and WRB each ...

1992-01-01

490

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...

2003-01-01

491

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

492

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

493

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...

1985-01-01

494

Direct digital radiography vs conventional radiography of thoracic spine: a comparative study  

International Nuclear Information System (INIS)

Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...

2005-09-01

495

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

496

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

497

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

498

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01