  1. Impact of digitalization of mammographic units on average glandular doses in the Flemish Breast Cancer Screening Program

    OpenAIRE

    De Hauwere, An; Thierens, Hubert

    2012-01-01

    The impact of digitalization on the average glandular doses in 49 mammographic units participating in the Flemish Breast Cancer Screening Program was studied. Screen-film was changed to direct digital radiography and computed radiography in 25 and 24 departments respectively. Average glandular doses were calculated before and after digitalization for different PMMA-phantom thicknesses and for groups of 50 successive patients. For the transition from screen-film to computed radiography both ph...

  2. Radiologists' preferences for digital mammographic display. The International Digital Mammography Development Group.

    Science.gov (United States)

    Pisano, E D; Cole, E B; Major, S; Zong, S; Hemminger, B M; Muller, K E; Johnston, R E; Walsh, R; Conant, E; Fajardo, L L; Feig, S A; Nishikawa, R M; Yaffe, M J; Williams, M B; Aylward, S R

    2000-09-01

    To determine the preferences of radiologists among eight different image processing algorithms applied to digital mammograms obtained for screening and diagnostic imaging tasks. Twenty-eight images representing histologically proved masses or calcifications were obtained by using three clinically available digital mammographic units. Images were processed and printed on film by using manual intensity windowing, histogram-based intensity windowing, mixture model intensity windowing, peripheral equalization, multiscale image contrast amplification (MUSICA), contrast-limited adaptive histogram equalization, Trex processing, and unsharp masking. Twelve radiologists compared the processed digital images with screen-film mammograms obtained in the same patient for breast cancer screening and breast lesion diagnosis. For the screening task, screen-film mammograms were preferred to all digital presentations, but the acceptability of images processed with Trex and MUSICA algorithms were not significantly different. All printed digital images were preferred to screen-film radiographs in the diagnosis of masses; mammograms processed with unsharp masking were significantly preferred. For the diagnosis of calcifications, no processed digital mammogram was preferred to screen-film mammograms. When digital mammograms were preferred to screen-film mammograms, radiologists selected different digital processing algorithms for each of three mammographic reading tasks and for different lesion types. Soft-copy display will eventually allow radiologists to select among these options more easily.

  3. Advanced techniques in digital mammographic images recognition

    International Nuclear Information System (INIS)

    Aliu, R. Azir

    2011-01-01

    Computer Aided Detection and Diagnosis is used in digital radiography as a second thought in the process of determining diagnoses, which reduces the percentage of wrong diagnoses of the established interpretation of mammographic images. The issues that are discussed in the dissertation are the analyses and improvement of advanced technologies in the field of artificial intelligence, more specifically in the field of machine learning for solving diagnostic problems and automatic detection of speculated lesions in digital mammograms. The developed of SVM-based ICAD system with cascade architecture for analyses and comparison mammographic images in both projections (CC and MLO) gives excellent result for detection and masses and microcalcifications. In order to develop a system with optimal performances of sensitivity, specificity and time complexity, a set of relevant characteristics need to be created which will show all the pathological regions that might be present in the mammographic image. The structure of the mammographic image, size and the large number of pathological structures in this area are the reason why the creation of a set of these features is necessary for the presentation of good indicators. These pathological structures are a real challenge today and the world of science is working in that direction. The doctoral dissertation showed that the system has optimal results, which are confirmed by experts, and institutions, which are dealing with these same issues. Also, the thesis presents a new approach for automatic identification of regions of interest in the mammographic image where regions of interest are automatically selected for further processing mammography in cases when the number of examined patients is higher. Out of 480 mammographic images downloaded from MIAS database and tested with ICAD system the author shows that, after separation and selection of relevant features of ICAD system the accuracy is 89.7% (96.4% for microcalcifications

  4. Monte Carlo simulation of a mammographic test phantom

    International Nuclear Information System (INIS)

    Hunt, R. A.; Dance, D. R.; Pachoud, M.; Carlsson, G. A.; Sandborg, M.; Ullman, G.

    2005-01-01

    A test phantom, including a wide range of mammographic tissue equivalent materials and test details, was imaged on a digital mammographic system. In order to quantify the effect of scatter on the contrast obtained for the test details, calculations of the scatter-to-primary ratio (S/P) have been made using a Monte Carlo simulation of the digital mammographic imaging chain, grid and test phantom. The results show that the S/P values corresponding to the imaging conditions used were in the range 0.084-0.126. Calculated and measured pixel values in different regions of the image were compared as a validation of the model and showed excellent agreement. The results indicate the potential of Monte Carlo methods in the image quality-patient dose process optimisation, especially in the assessment of imaging conditions not available on standard mammographic units. (authors)

  5. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    International Nuclear Information System (INIS)

    Chon, Kwon Su; Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha

    2009-01-01

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-μm thickness. With a thicker molybdenum filter (100 μm thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-μm thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue

  6. Usefulness of a Small-Field Digital Mammographic Imaging System Using Parabolic Polycapillary Optics as a Diagnostic Imaging Tool: a Preliminary Study

    Energy Technology Data Exchange (ETDEWEB)

    Chon, Kwon Su [Catholic University of Daegu, Daegu (Korea, Republic of); Park, Jeong Gon; Son, Hyun Hwa; Kang, Sung Hoon; Park, Seong Hoon; Kim, Hye Won; Kim, Hun Soo; Yoon, Kwon Ha [Wonkwang University, Iksan (Korea, Republic of)

    2009-12-15

    To evaluate the efficacy for spatial resolution and radiation dose of a small-field digital mammographic imaging system using parabolic polycapillary optics. We developed a small-field digital mammographic imaging system composed of a CCD (charge coupled device) detector and an Xray source coupled with parabolic polycapillary optics. The spatial resolution and radiation dose according to various filters were evaluated for a small-field digital mammographic imaging system. The images of a test standard phantom and breast cancer tissue sample were obtained. The small-field digital mammographic imaging system had spatial resolutions of 12 lp/mm with molybdenum and rhodium filters with a 25-{mu}m thickness. With a thicker molybdenum filter (100 {mu}m thick), the system had a higher spatial resolution of 11 lp/mm and contrast of 0.48. The radiation dose for a rhodium filter with a 25-{mu}m thickness was 0.13 mGy within a 10-mm-diameter local field. A larger field image greater than 10 mm in diameter could be obtained by scanning an object. On the small-field mammographic imaging system, microcalcifications of breast cancer tissue were clearly observed. A small-field digital mammographic imaging system with parabolic polycapillary optics may be a useful diagnostic tool for providing high-resolution imaging with a low radiation dose for examination of local volumes of breast tissue.

  7. Image quality analysis of digital mammographic equipments

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, P.; Pascual, A.; Verdu, G. [Valencia Univ. Politecnica, Chemical and Nuclear Engineering Dept. (Spain); Rodenas, F. [Valencia Univ. Politecnica, Applied Mathematical Dept. (Spain); Campayo, J.M. [Valencia Univ. Hospital Clinico, Servicio de Radiofisica y Proteccion Radiologica (Spain); Villaescusa, J.I. [Hospital Clinico La Fe, Servicio de Proteccion Radiologica, Valencia (Spain)

    2006-07-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  8. Image quality analysis of digital mammographic equipments

    International Nuclear Information System (INIS)

    Mayo, P.; Pascual, A.; Verdu, G.; Rodenas, F.; Campayo, J.M.; Villaescusa, J.I.

    2006-01-01

    The image quality assessment of a radiographic phantom image is one of the fundamental points in a complete quality control programme. The good functioning result of all the process must be an image with an appropriate quality to carry out a suitable diagnostic. Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is C.D.M.A.M. 3.4, which facilitates the evaluation of image contrast and detail resolution. One of the most extended indexes to measure the image quality in an objective way is the Image Quality Figure (I.Q.F.). This parameter is useful to calculate the image quality taking into account the contrast and detail resolution of the image analysed. The contrast-detail curve is useful as a measure of the image quality too, because it is a graphical representation in which the hole thickness and diameter are plotted for each contrast-detail combination detected in the radiographic image of the phantom. It is useful for the comparison of the functioning of different radiographic image systems, for phantom images under the same exposition conditions. The aim of this work is to study the image quality of different images contrast-detail phantom C.D.M.A.M. 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments. (authors)

  9. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.

    Science.gov (United States)

    Chiarelli, Anna M; Prummel, Maegan V; Muradali, Derek; Shumak, Rene S; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Done, Susan J; Yaffe, Martin J

    2015-11-01

    Most studies that have examined the effects of mammographic density and hormone therapy use on breast cancer detection have included screen-film mammography. This study further examines this association in post-menopausal women screened by digital mammography. Approved by the University of Toronto Research Ethics Board, this study identified 688,418 women of age 50-74 years screened with digital or screen-film mammography from 2008 to 2009 within the Ontario Breast Screening Program. Of 2993 eligible women with invasive breast cancer, 2450 were contacted and 1421 participated (847 screen-film mammography, 574 digital direct radiography). Mammographic density was measured by study radiologists using the standard BI-RADS classification system and by a computer-assisted method. Information on hormone therapy use was collected by a telephone-administered questionnaire. Logistic regression and two-tailed tests for significance evaluated associations between factors and detection method by mammography type. Women with >75 % radiologist-measured mammographic density compared to those with diagnosed with an interval than screen-detected cancer, with the difference being greater for those screened with screen-film (OR = 6.40, 95 % CI 2.30-17.85) than digital mammography (OR = 2.41, 95 % CI 0.67-8.58) and aged 50-64 years screened with screen-film mammography (OR = 10.86, 95 % CI 2.96-39.57). Recent former hormone therapy users were also at an increased risk of having an interval cancer with the association being significant for women screened with digital mammography (OR = 2.08, 95 % CI 1.17-3.71). Breast screening using digital mammography lowers the risk of having an interval cancer for post-menopausal women aged 50-64 with greater mammographic density.

  10. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    International Nuclear Information System (INIS)

    Annovazzi, A.; Amendolia, S.R.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Colombo, F.; Delogu, P.; Fantacci, M.E.; Gilberti, A.; Lanzieri, C.; Lavagna, S.; Novelli, M.; Passuello, G.; Paternoster, G.; Pieracci, M.; Poletti, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.; Testa, A.; Venturelli, L.

    2007-01-01

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm 2 therefore to cover the typical irradiation field used in mammography (18x24 cm 2 ), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma 'La Sapienza', Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%

  11. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    Science.gov (United States)

    Annovazzi, A.; Amendolia, S. R.; Bigongiari, A.; Bisogni, M. G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Colombo, F.; Delogu, P.; Fantacci, M. E.; Gilberti, A.; Lanzieri, C.; Lavagna, S.; Novelli, M.; Passuello, G.; Paternoster, G.; Pieracci, M.; Poletti, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.; Testa, A.; Venturelli, L.

    2007-06-01

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm 2 therefore to cover the typical irradiation field used in mammography (18×24 cm 2), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma "La Sapienza", Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%.

  12. A GaAs pixel detectors-based digital mammographic system: Performances and imaging tests results

    Energy Technology Data Exchange (ETDEWEB)

    Annovazzi, A. [LABEN S.p.A., Vimodrone-Milan (Italy); Amendolia, S.R. [Str. Dip. di Matematica e Fisica dell' Universita, Sassari and Sezione I.N.F.N., Pisa (Italy); Bigongiari, A. [CAEN S.p.A., Viareggio-Lucca (Italy); Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Catarsi, F. [CAEN S.p.A., Viareggio-Lucca (Italy); Cesqui, F. [AMS S.p.A, Rome (Italy); Cetronio, A. [AMS S.p.A, Rome (Italy); Colombo, F. [LABEN S.p.A., Vimodrone-Milan (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Gilberti, A. [LABEN S.p.A., Vimodrone-Milan (Italy); Lanzieri, C. [AMS S.p.A, Rome (Italy); Lavagna, S. [AMS S.p.A, Rome (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Passuello, G. [CAEN S.p.A., Viareggio-Lucca (Italy); Paternoster, G. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Pieracci, M. [CAEN S.p.A., Viareggio-Lucca (Italy); Poletti, M. [LABEN S.p.A., Vimodrone-Milan (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' dell' Universita and Sezione I.N.F.N., Pisa (Italy)]. E-mail: arnaldo.stefanini@pi.infn.it; Testa, A. [CAEN S.p.A., Viareggio-Lucca (Italy); Venturelli, L. [AMS S.p.A, Rome (Italy)

    2007-06-11

    The prototype presented in this paper is based on GaAs pixel detectors read-out by the PCC/MEDIPIX I circuit. The active area of a sensor is about 1 cm{sup 2} therefore to cover the typical irradiation field used in mammography (18x24 cm{sup 2}), 18 GaAs detection units have been organized in two staggered rows of nine chips each and moved by a stepper motor in the orthogonal direction. The system is integrated in a mammographic equipment which comprehends the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the Integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies, Alenia Marconi Systems (AMS), CAEN, Gilardoni, LABEN and Poli.Hi.Tech., in collaboration with the universities of Ferrara, Roma 'La Sapienza', Pisa and the Istituto Nazionale di Fisica Nucleare (INFN). In this paper, we report on the electrical characterization and the first imaging test results of the digital mammographic system. To assess the imaging capability of such a detector we have built a phantom, which simulates the breast tissue with malignancies. The radiographs of the phantom, obtained by delivering an entrance dose of 4.8 mGy, have shown particulars with a measured contrast below 1%.

  13. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Destounis, Stamatia [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States); University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States); Hanson, Sarah; Morgan, Renee; Murphy, Philip; Somerville, Patricia; Seifert, Posy; Andolina, Valerie; Arieno, Andrea; Skolny, Melissa; Logan-Young, Wende [Elizabeth Wende Breast Care, LLC, Rochester, NY (United States)

    2009-06-15

    A retrospective evaluation of the ability of computer-aided detection (CAD) ability to identify breast carcinoma in standard mammographic projections. Forty-five biopsy proven lesions in 44 patients imaged digitally with CAD applied at examination were reviewed. Forty-four screening BIRADS {sup registered} category 1 digital mammography examinations were randomly identified to serve as a comparative normal/control population. Data included patient age; BIRADS {sup registered} breast density; lesion type, size, and visibility; number, type, and location of CAD marks per image; CAD ability to mark lesions; needle core and surgical pathologic correlation. The CAD lesion/case sensitivity of 87% (n=39), image sensitivity of 69% (n=31) for mediolateral oblique view and 78% (n=35) for the craniocaudal view was found. The average false positive rate in 44 normal screening cases was 2.0 (range 1-8). The 2.0 figure is based on 88 reported false positive CAD marks in 44 normal screening exams: 98% (n=44) lesions proceeded to excision; initial pathology upgraded at surgical excision from in situ to invasive disease in 24% (n=9) lesions. CAD demonstrated potential to detect mammographically visible cancers in standard projections for all lesion types. (orig.)

  14. Dose surveys in two digital mammography units using DICOM headers

    International Nuclear Information System (INIS)

    Tsalafoutas, I.; Michalaki, C.; Papagiannopoulou, C.; Efstathopoulos, E.

    2012-01-01

    Background and objective: Digital mammography units store images in DICOM format. Thus, data regarding the acquisition parameters are available within DICOM headers, including among others, the anode/filter combination, tube potential and tube current exposure time product, compressed breast thickness, entrance surface air kerma (ESAK) and mean glandular dose (MGD). However, manual extraction of these data for the verification of the displayed values' accuracy and for dose survey purposes is time consuming. Our objective was to develop a method that enables the automation of such procedures. Materials and methods: Two hundred mammographic examinations (800 mammograms) performed in two digital units (GE, Essential) were recorded on CD-roms. Using appropriate software (DICOM Info Extractor) all dose related DICOM headers were extracted into a Microsoft Excel based spreadsheet, containing embedded algorithms for the calculation of ESAK and MGD according to Dance et al (Phys. Med. Biol. 45, 2000) methodology. Results: The ESAK and MGD values stored in the DICOM headers were compared with those calculated and in most cases were within ±10%. The basic difference among the two mammographic units is that, the older one calculates MGD assuming a breast composition 50% glandular-50% adipose tissue, while the newer one calculates the actual breast glandularity and stores this value in a DICOM header. The average MGD values were 1.21 mGy and 1.38 mGy, respectively. Conclusion: For the units studied, the ESAK and MGD values stored in DICOM headers are reliable. Utilizing tools for their automatic extraction provides an easy way to perform dose surveys. (authors)

  15. Computer-aided detection of breast carcinoma in standard mammographic projections with digital mammography

    International Nuclear Information System (INIS)

    Destounis, S.; Hanson, S.

    2007-01-01

    This study was conducted to retrospectively evaluate a computer-aided detection system's ability to detect breast carcinoma in multiple standard mammographic projections. Forty-five lesions in 44 patients imaged with digital mammography (Selenia registered , Hologic, Bedford, MA; Senographe registered , GE, Milwaukee, WI) and had computer-aided detection (CAD, Image-checker registered V 8.3.15, Hologic/R2, Santa Clara, CA) applied at the time of examination were identified for review; all were subsequently recommended to biopsy where cancer was revealed. These lesions were determined by the study Radiologist to be visible in both standard mammographic images (mediolateral oblique, MLO; craniocaudal, CC). For each patient, case data included patient age, tissue density, lesion type, BIRADS registered assessment, lesion size, lesion visibility-visible on MLO and/or CC view, ability of CAD to correctly mark the cancerous lesion, number of CAD marks per image, needle core biopsy results and surgical pathologic correlation. For this study cohort. CAD lesion/case sensitivity of 87% (n = 39) was found and image sensitivity was found to be 69% (n = 31) for MLO view and 78% (n = 35) for the CC view. For the study cohort, cases presented with a median of four marks per cases (range 0-13). Eighty-four percent (n = 38) of lesions proceeded to excision; initial needle biopsy pathology was upgraded at surgical excision from in situ disease to invasive for 24% (n = 9) lesions. CAD has demonstrated the potential to detect mammographically visible cancers in multiple standard mammographic projections in all categories of lesions in this study cohort. (orig.)

  16. Comparative study on mammographic findings between conventional mammography and digital mammography

    International Nuclear Information System (INIS)

    Gonzalez Calle, Aurelio; Saldarriaga Jaramillo, Ximena; Zapata Walliser, Luz Estela; Mejia Restrepo, Jorge Hernando; Arango Martinez, Adriana; Velez Arango, Jorge Mario

    2007-01-01

    We performed conventional-film mammograms in 180 patients between 35 and 6 years and additionally, we added 2 digital CR technique images to each patient, either craneocaudal (90 patients) or oblique (90 patients). All images were interpreted independently by four radiologists for a total of 720 evaluations, who compared film versus digital images through a 5 mega pixel monitor (soft-copy), using a score scale using the following parameters: mass visualization, detection of micro-calcifications, architectural distortion, visibility of the skin line, and image sharpness and noise. Additionally the tissue density was classified as well as the BIRADS score. The data was processed with the Teleform program and analyzed by de SPSSS program. Results: 52.6% of the micro-calcifications were equally visualized with both systems, in 13.5% of the cases they were better visualized with digital mammography. Similarly, in 50% of the cases, the skin line was better visualized with the digital CR modality. Conclusion: the sharpness of the image was also better seen with the digital CR technique in 48.2%. On the contrary, more noise was seen in digital CR images (63%). digital mammography is a diagnostic alternative that can improve mammographic findings detection and finally become a useful tool in breast cancer diagnosis

  17. Quality Control and Dosimetry in Mammographic Units in Greece

    Energy Technology Data Exchange (ETDEWEB)

    Flioni-Vysa, A; Xenofos, S; Stamatelatos, E; Georgolopoulou, P [Department of Medical Physics, Saint Savvas Hospital, 171 Alexandras Avenue, Athens 115 22, (Greece)

    1994-12-31

    Quality control measurements have been carried out on 29 mammographic units. It was found that a large percentage of users obtained Optical Densities outside the recommended values. Resolution under routine conditions was below the limit of 14 lp/mm in about 50% of the units. The skin entrance dose was in a few cases in excess of 10 micro Gray, but the mean value was well below this upper limit. Analysis of the results obtained has indicated that proper calibration of kilo voltage panel indications and automatic exposure control systems is of outmost importance and should be performed regularly. (authors). 11 refs, 2 figs 3 tabs.

  18. Task-Specific Optimization of Mammographic Systems

    National Research Council Canada - National Science Library

    Saunders, Robert

    2005-01-01

    .... This model was verified by a human observer performance experiment. The next objective explored the physical properties of a digital mammographic system, including resolution, noise, efficiency, and lag...

  19. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Mayo, Patricia, E-mail: p.mayo@titaniast.co [Titania Servicios Tecnologicos S.L., Grupo Dominguis, Apartado 46015, Valencia (Spain); Rodenas, Francisco [Departamento de Matematica Aplicada, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain); Manuel Campayo, Juan [Hospital Clinico Universitario de Valencia, Avda. Blasco Ibanez, Apartado 46017, Valencia (Spain); Verdu, Gumersido [Departamento de Ingenieria Quimica y Nuclear, Universidad Politecnica de Valencia, Apartado 46022, Valencia (Spain)

    2010-07-21

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  20. Quality assurance applied to mammographic equipments using phantoms and software for its evaluation

    International Nuclear Information System (INIS)

    Mayo, Patricia; Rodenas, Francisco; Manuel Campayo, Juan; Verdu, Gumersido

    2010-01-01

    The image quality assessment in radiographic equipments is a very important item for a complete quality control of the radiographic image chain. The periodic evaluation of the radiographic image quality must guarantee the constancy of this quality to carry out a suitable diagnosis. Mammographic phantom images are usually used to study the quality of images obtained by determined mammographic equipment. The digital image treatment techniques allow to carry out an automatic analysis of the phantom image. In this work we apply some techniques of digital image processing to analyze in an automatic way the image quality of mammographic phantoms, namely CIRS SP01 and RACON for different varying conditions of the mammographic equipment. The CIRS SP01 phantom is usually used in analogic mammographic equipments and the RACON phantom has been specifically developed by authors to be applied to acceptance and constancy tests of the image quality in digital radiographic equipments following recommendations of international associations. The purpose of this work consists in analyzing the image quality for both phantoms by means of an automatic software utility. This analysis allows us to study the functioning of the image chain of the mammographic system in an objective way, so an abnormal functioning of the radiographic equipment might be detected.

  1. Mammographic image enhancement using wavelet transform and homomorphic filter

    Directory of Open Access Journals (Sweden)

    F Majidi

    2015-12-01

    Full Text Available Mammography is the most effective method for the early diagnosis of breast cancer diseases. As mammographic images contain low signal to noise ratio and low contrast, it becomes too difficult for radiologists to analyze mammogram. To deal with the above stated problems, it is very important to enhance the mammographic images using image processing methods. This paper introduces a new image enhancement approach for mammographic images which uses the modified mathematical morphology, wavelet transform and homomorphic filter to suppress the noise of images. For performance evaluation of the proposed method, contrast improvement index (CII and edge preservation index (EPI are adopted. Experimental results on mammographic images from Pejvak Digital Imaging Center (PDIC show that the proposed algorithm improves the two indexes, thereby achieving the goal of enhancing mammographic images.

  2. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Mark, E-mail: marktknox@gmail.com; O’Brien, Angela, E-mail: angelaobrien@doctors.org.uk; Szabó, Endre, E-mail: endrebacsi@freemail.hu; Smith, Clare S., E-mail: csmith@mater.ie; Fenlon, Helen M., E-mail: helen.fenlon@cancerscreening.ie; McNicholas, Michelle M., E-mail: michelle.mcnicholas@cancerscreening.ie; Flanagan, Fidelma L., E-mail: fidelma.flanagan@cancerscreening.ie

    2015-06-15

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications.

  3. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    International Nuclear Information System (INIS)

    Knox, Mark; O’Brien, Angela; Szabó, Endre; Smith, Clare S.; Fenlon, Helen M.; McNicholas, Michelle M.; Flanagan, Fidelma L.

    2015-01-01

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications

  4. Volumetric breast density affects performance of digital screening mammography

    OpenAIRE

    Wanders, JO; Holland, K; Veldhuis, WB; Mann, RM; Pijnappel, RM; Peeters, PH; Van Gils, CH; Karssemeijer, N

    2016-01-01

    PURPOSE: To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). METHODS: We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the Ameri...

  5. Diagnostic implications of asymmetrical mammographic patterns

    International Nuclear Information System (INIS)

    Asenjo, M.; Ania, B.J.

    1997-01-01

    To analyze the effect of asymmetrical mammographic patterns of the diagnosis of breast cancer. In a series of 6, 476 patients referred to a Breast Imaging Diagnosis Unit, we excluded males, women with previous breast surgery, and cases in which mammography was not performed, which left 5,203 women included. Each breast was classified according to one of four patterns of mammographic parenchymal density. Asymmetry was considered to exist when a patient's breasts had different patterns. Breast cancer was confirmed histologically in 282 (5.4%) women. The mammographic pattern was asymmetrical in 8% of the women with cancer and in 2% of the women without cancer (p<0.001). Fine-needle aspiration biopsy was performed in 78% and 96% (p=0.04), respectively, of the women with and without mammographic asymmetry who had neoplasms, and in 33% and 22% (p=0.02), respectively, of the women with and without mammographic asymmetry who did not have neoplasms. Asymmetrical mammographic pattern was four times more frequent in the women with breast cancer. This asymmetry decreased the frequency of needle biopsy in women with cancer, but increased the frequency of needle biopsy in women without cancer. (Author) 11 refs

  6. Neural network recognition of mammographic lesions

    International Nuclear Information System (INIS)

    Oldham, W.J.B.; Downes, P.T.; Hunter, V.

    1987-01-01

    A method for recognition of mammographic lesions through the use of neural networks is presented. Neural networks have exhibited the ability to learn the shape andinternal structure of patterns. Digitized mammograms containing circumscribed and stelate lesions were used to train a feedfoward synchronous neural network that self-organizes to stable attractor states. Encoding of data for submission to the network was accomplished by performing a fractal analysis of the digitized image. This results in scale invariant representation of the lesions. Results are discussed

  7. The Mammographic Head Demonstrator Developed in the Framework of the “IMI” Project:. First Imaging Tests Results

    Science.gov (United States)

    Bisogni, Maria Giuseppina

    2006-04-01

    In this paper we report on the performances and the first imaging test results of a digital mammographic demonstrator based on GaAs pixel detectors. The heart of this prototype is the X-ray detection unit, which is a GaAs pixel sensor read-out by the PCC/MEDIPIXI circuit. Since the active area of the sensor is 1 cm2, 18 detectors have been organized in two staggered rows of nine chips each. To cover the typical mammographic format (18 × 24 cm2) a linear scanning is performed by means of a stepper motor. The system is integrated in mammographic equipment comprehending the X-ray tube, the bias and data acquisition systems and the PC-based control system. The prototype has been developed in the framework of the integrated Mammographic Imaging (IMI) project, an industrial research activity aiming to develop innovative instrumentation for morphologic and functional imaging. The project has been supported by the Italian Ministry of Education, University and Research (MIUR) and by five Italian High Tech companies in collaboration with the universities of Ferrara, Roma “La Sapienza”, Pisa and the INFN.

  8. Practical digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Beverly E. [Washington Univ., Seattle, WA (United States)]|[Virginia Mason Medical Center, VA (United States)

    2008-07-01

    This book is meant for the radiologist who is facing the challenge of organizing a digital mammographic imaging center. This text is meant to be a practical book that provides information about digital mammographic physics and equipment which will allow one to intelligently compare technologies and systems. Some of the major challenges include: large expense; rapidly changing technology, and inconsistent connectivity; and finally, need for strong information technology support. The initial conversion cost to digital mammographic imaging is relatively expensive due to the cost of digital mammography hardware, software, and storage. Virtually all other imaging modalities are being converted to purely digital storage and transfer, and the digital trend in mammography is inevitable. Technical advantages of digital mammography are described. However, the improved flexibility in image display and transfer are some of its strongest features. In conclusion, although there are increasing imaging modalities that may be used to evaluate breast disease, mammography will continue to play a key role in detecting breast cancer. To be an effective imager, the radiologist should become familiar with digital mammography and understand its role within the increasing complex structure of breast imaging techniques.

  9. Practical digital mammography

    International Nuclear Information System (INIS)

    Hashimoto, Beverly E.

    2008-01-01

    This book is meant for the radiologist who is facing the challenge of organizing a digital mammographic imaging center. This text is meant to be a practical book that provides information about digital mammographic physics and equipment which will allow one to intelligently compare technologies and systems. Some of the major challenges include: large expense; rapidly changing technology, and inconsistent connectivity; and finally, need for strong information technology support. The initial conversion cost to digital mammographic imaging is relatively expensive due to the cost of digital mammography hardware, software, and storage. Virtually all other imaging modalities are being converted to purely digital storage and transfer, and the digital trend in mammography is inevitable. Technical advantages of digital mammography are described. However, the improved flexibility in image display and transfer are some of its strongest features. In conclusion, although there are increasing imaging modalities that may be used to evaluate breast disease, mammography will continue to play a key role in detecting breast cancer. To be an effective imager, the radiologist should become familiar with digital mammography and understand its role within the increasing complex structure of breast imaging techniques

  10. Enhancement and denoising of mammographic images for breast disease detection

    International Nuclear Information System (INIS)

    Yazdani, S.; Yusof, R.; Karimian, A.; Hematian, A.; Yousefi, M.

    2012-01-01

    In these two decades breast cancer is one of the leading cause of death among women. In breast cancer research, Mammographic Image is being assessed as a potential tool for detecting breast disease and investigating response to chemotherapy. In first stage of breast disease discovery, the density measurement of the breast in mammographic images provides very useful information. Because of the importance of the role of mammographic images the need for accurate and robust automated image enhancement techniques is becoming clear. Mammographic images have some disadvantages such as, the high dependence of contrast upon the way the image is acquired, weak distinction in splitting cyst from tumor, intensity non uniformity, the existence of noise, etc. These limitations make problem to detect the typical signs such as masses and microcalcifications. For this reason, denoising and enhancing the quality of mammographic images is very important. The method which is used in this paper is in spatial domain which its input includes high, intermediate and even very low contrast mammographic images based on specialist physician's view, while its output is processed images that show the input images with higher quality, more contrast and more details. In this research, 38 mammographic images have been used. The result of purposed method shows details of abnormal zones and the areas with defects so that specialist could explore these zones more accurately and it could be deemed as an index for cancer diagnosis. In this study, mammographic images are initially converted into digital images and then to increase spatial resolution power, their noise is reduced and consequently their contrast is improved. The results demonstrate effectiveness and efficiency of the proposed methods. (authors)

  11. Digital mammographic tumor classification using transfer learning from deep convolutional neural networks.

    Science.gov (United States)

    Huynh, Benjamin Q; Li, Hui; Giger, Maryellen L

    2016-07-01

    Convolutional neural networks (CNNs) show potential for computer-aided diagnosis (CADx) by learning features directly from the image data instead of using analytically extracted features. However, CNNs are difficult to train from scratch for medical images due to small sample sizes and variations in tumor presentations. Instead, transfer learning can be used to extract tumor information from medical images via CNNs originally pretrained for nonmedical tasks, alleviating the need for large datasets. Our database includes 219 breast lesions (607 full-field digital mammographic images). We compared support vector machine classifiers based on the CNN-extracted image features and our prior computer-extracted tumor features in the task of distinguishing between benign and malignant breast lesions. Five-fold cross validation (by lesion) was conducted with the area under the receiver operating characteristic (ROC) curve as the performance metric. Results show that classifiers based on CNN-extracted features (with transfer learning) perform comparably to those using analytically extracted features [area under the ROC curve [Formula: see text

  12. Uncertainties of exposure-related quantities in mammographic x-ray unit quality control

    International Nuclear Information System (INIS)

    Gregory, Kent J.; Pattison, John E.; Bibbo, Giovanni

    2006-01-01

    Breast screening programs operate in many countries with mammographic x-ray units subject to stringent quality control tests. These tests include the evaluation of quantities based on exposure measurements, such as half value layer, automatic exposure control reproducibility, average glandular dose, and radiation output rate. There are numerous error sources that contribute to the uncertainty of these exposure-related quantities, some of which are unique to the low energy x-ray spectrum produced by mammographic x-ray units. For each of these exposure-related quantities, the applicable error sources and their magnitudes vary, depending on the test equipment used to make the measurement, and whether or not relevant corrections have been applied. This study has identified and quantified a range of error sources that may be used to estimate the combined uncertainty of these exposure-related quantities, given the test equipment used and corrections applied. The uncertainty analysis uses methods described by the International Standards Organization's Guide to the Expression of Uncertainty in Measurement. Examples of how these error sources combine to give the uncertainty of the exposure-related quantities are presented. Using the best test equipment evaluated in this study, uncertainties of the four exposure-related quantities at the 95% confidence interval were found to be ±1.6% (half value layer), ±0.0008 (automatic exposure control reproducibility), ±2.3% (average glandular dose), and ±2.1% (radiation output rate). In some cases, using less precise test equipment or failing to apply corrections, resulted in uncertainties more than double in magnitude

  13. Mammographic density and breast cancer risk in breast screening assessment cases and women with a family history of breast cancer.

    Science.gov (United States)

    Duffy, Stephen W; Morrish, Oliver W E; Allgood, Prue C; Black, Richard; Gillan, Maureen G C; Willsher, Paula; Cooke, Julie; Duncan, Karen A; Michell, Michael J; Dobson, Hilary M; Maroni, Roberta; Lim, Yit Y; Purushothaman, Hema N; Suaris, Tamara; Astley, Susan M; Young, Kenneth C; Tucker, Lorraine; Gilbert, Fiona J

    2018-01-01

    Mammographic density has been shown to be a strong independent predictor of breast cancer and a causative factor in reducing the sensitivity of mammography. There remain questions as to the use of mammographic density information in the context of screening and risk management, and of the association with cancer in populations known to be at increased risk of breast cancer. To assess the association of breast density with presence of cancer by measuring mammographic density visually as a percentage, and with two automated volumetric methods, Quantra™ and VolparaDensity™. The TOMosynthesis with digital MammographY (TOMMY) study of digital breast tomosynthesis in the Breast Screening Programme of the National Health Service (NHS) of the United Kingdom (UK) included 6020 breast screening assessment cases (of whom 1158 had breast cancer) and 1040 screened women with a family history of breast cancer (of whom two had breast cancer). We assessed the association of each measure with breast cancer risk in these populations at enhanced risk, using logistic regression adjusted for age and total breast volume as a surrogate for body mass index (BMI). All density measures showed a positive association with presence of cancer and all declined with age. The strongest effect was seen with Volpara absolute density, with a significant 3% (95% CI 1-5%) increase in risk per 10 cm 3 of dense tissue. The effect of Volpara volumetric density on risk was stronger for large and grade 3 tumours. Automated absolute breast density is a predictor of breast cancer risk in populations at enhanced risk due to either positive mammographic findings or family history. In the screening context, density could be a trigger for more intensive imaging. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Improved mammographic interpretation of masses using computer-aided diagnosis

    International Nuclear Information System (INIS)

    Leichter, I.; Fields, S.; Novak, B.; Nirel, R.; Bamberger, P.; Lederman, R.; Buchbinder, S.

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p z ) increased significantly (p z for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the unassisted radiologist. Our findings suggest that objective quantitative features extracted from digitized mammographic findings may help in differentiating between benign and malignant masses, and can assist the radiologist in the interpretation of mass lesions. (orig.)

  15. Performances of different digital mammography imaging systems: Evaluation and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)]. E-mail: giuseppina.bisogni@pi.infn.it; Bulajic, D. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); International Centre for Theoretical Physics, Trieste (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)

    2005-07-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems.

  16. Performances of different digital mammography imaging systems: Evaluation and comparison

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Bulajic, D.; Delogu, P.; Fantacci, M.E.; Novelli, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.

    2005-01-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems

  17. Applying a new mammographic imaging marker to predict breast cancer risk

    Science.gov (United States)

    Aghaei, Faranak; Danala, Gopichandh; Hollingsworth, Alan B.; Stoug, Rebecca G.; Pearce, Melanie; Liu, Hong; Zheng, Bin

    2018-02-01

    Identifying and developing new mammographic imaging markers to assist prediction of breast cancer risk has been attracting extensive research interest recently. Although mammographic density is considered an important breast cancer risk, its discriminatory power is lower for predicting short-term breast cancer risk, which is a prerequisite to establish a more effective personalized breast cancer screening paradigm. In this study, we presented a new interactive computer-aided detection (CAD) scheme to generate a new quantitative mammographic imaging marker based on the bilateral mammographic tissue density asymmetry to predict risk of cancer detection in the next subsequent mammography screening. An image database involving 1,397 women was retrospectively assembled and tested. Each woman had two digital mammography screenings namely, the "current" and "prior" screenings with a time interval from 365 to 600 days. All "prior" images were originally interpreted negative. In "current" screenings, these cases were divided into 3 groups, which include 402 positive, 643 negative, and 352 biopsy-proved benign cases, respectively. There is no significant difference of BIRADS based mammographic density ratings between 3 case groups (p cancer detection in the "current" screening. Study demonstrated that this new imaging marker had potential to yield significantly higher discriminatory power to predict short-term breast cancer risk.

  18. Mammographic Breast Density in Malaysian Women with Breast Cancer

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung

    2016-01-01

    The objective of this study was to examine the mammographic breast density of women with breast cancer detected on voluntary mammographic screening at two selected screening centers in Malaysia. This was a retrospective study of Full-Field Digital Mammography (FFDM) images of 150 Malaysian women with biopsy-proven breast cancer. The study population comprised 73 Malays (37.7 %), 59 Chinese (39.3 %) and 18 Indians (12.0 %). The Tabar breast density Patterns (I - V) were used to evaluate mammographic breast density. Data were analyzed using descriptive statistics. The results were compared with findings from a similar study on a group of 668 women who did not have breast cancer. The results showed that 44.7 % of the study population had dense breasts (Patterns IV and V), 14.7 % had predominantly fatty breasts (Patterns II and III) while 40.7 % had Pattern I. The proportion of study population with dense breasts decreased with age. In conclusion, the proportion of women with dense breasts decreased with age. Majority of the women with cancer (44.7 %) had dense breasts of Tabar Patterns IV and V, which has been associated with increased risk of breast cancer detected by voluntary mammographic screening. The results support the notion that increased breast density is a risk factor of breast cancer. (author)

  19. Agreement of mammographic measures of volumetric breast density to MRI.

    Directory of Open Access Journals (Sweden)

    Jeff Wang

    Full Text Available Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known.To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population.Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume.Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2 values ranging from 0.40 (log fibroglandular volume to 0.91 (total breast volume. Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63, but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume.Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  20. Agreement of mammographic measures of volumetric breast density to MRI.

    Science.gov (United States)

    Wang, Jeff; Azziz, Ania; Fan, Bo; Malkov, Serghei; Klifa, Catherine; Newitt, David; Yitta, Silaja; Hylton, Nola; Kerlikowske, Karla; Shepherd, John A

    2013-01-01

    Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.

  1. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  2. Minimization of annotation work: diagnosis of mammographic masses via active learning

    Science.gov (United States)

    Zhao, Yu; Zhang, Jingyang; Xie, Hongzhi; Zhang, Shuyang; Gu, Lixu

    2018-06-01

    The prerequisite for establishing an effective prediction system for mammographic diagnosis is the annotation of each mammographic image. The manual annotation work is time-consuming and laborious, which becomes a great hindrance for researchers. In this article, we propose a novel active learning algorithm that can adequately address this problem, leading to the minimization of the labeling costs on the premise of guaranteed performance. Our proposed method is different from the existing active learning methods designed for the general problem as it is specifically designed for mammographic images. Through its modified discriminant functions and improved sample query criteria, the proposed method can fully utilize the pairing of mammographic images and select the most valuable images from both the mediolateral and craniocaudal views. Moreover, in order to extend active learning to the ordinal regression problem, which has no precedent in existing studies, but is essential for mammographic diagnosis (mammographic diagnosis is not only a classification task, but also an ordinal regression task for predicting an ordinal variable, viz. the malignancy risk of lesions), multiple sample query criteria need to be taken into consideration simultaneously. We formulate it as a criteria integration problem and further present an algorithm based on self-adaptive weighted rank aggregation to achieve a good solution. The efficacy of the proposed method was demonstrated on thousands of mammographic images from the digital database for screening mammography. The labeling costs of obtaining optimal performance in the classification and ordinal regression task respectively fell to 33.8 and 19.8 percent of their original costs. The proposed method also generated 1228 wins, 369 ties and 47 losses for the classification task, and 1933 wins, 258 ties and 185 losses for the ordinal regression task compared to the other state-of-the-art active learning algorithms. By taking the

  3. Mammographic interpretation

    International Nuclear Information System (INIS)

    Tabor, L.

    1987-01-01

    For mammography to be an effective diagnostic method, it must be performed to a very high standard of quality. Otherwise many lesions, in particular cancer in its early stages, will simply not be detectable on the films, regardless of the skill of the mammographer. Mammographic interpretation consists of two basic steps: perception and analysis. The process of mammographic interpretation begins with perception of the lesion on the mammogram. Perception is influenced by several factors. One of the most important is the parenchymal pattern of the breast tissue, detection of pathologic lesions being easier with fatty involution. The mammographer should use a method for the systematic viewing of the mammograms that will ensure that all parts of each mammogram are carefully searched for the presence of lesions. The method of analysis proceeds according to the type of lesion. The contour analysis of primary importance in the evaluation of circumscribed tumors. After having analyzed the contour and density of a lesion and considered its size, the mammographer should be fairly certain whether the circumscribed tumor is benign or malignant. Fine-needle puncture and/or US may assist the mammographer in making this decision. Painstaking analysis is required because many circumscribed tumors do not need to be biopsied. The perception of circumscribed tumors seldom causes problems, but their analysis needs careful attention. On the other hand, the major challenge with star-shaped lesions is perception. They may be difficult to discover when small. Although the final diagnosis of a stellate lesion can be made only with the help of histologic examination, the preoperative mammorgraphic differential diagnosis can be highly accurate. The differential diagnostic problem is between malignant tumors (scirrhous carcinoma), on the one hand, and traumatic fat necrosis as well as radial scars on the other hand

  4. Mammographic Texture Resemblance generalizes as an independent risk factor of breast cancer

    DEFF Research Database (Denmark)

    Chernoff, Konstantin; Christopher, S G; Karemore, Gopal

    PURPOSE Breast density has been established as a risk factor of breast cancer in numerous studies. Mammographic Texture Resemblance (MTR) has shown to be a density independent risk factor, but only on a single study. We examine if the statistics of the texture recorded in one study generalize...... as an independent risk factor in an unrelated cohort. METHOD AND MATERIALS The statistics of texture were recorded in digitalized film-mammograms of one 4-year prospective study (S1, Dutch screening program) of 245 breast cancers and 250 matched controls. From an independent cohort study (S2, Mayo Mammography...... Health Study cohort) 226 incident breast cancer cases diagnosed through 2008 and 442 matched controls (on age) were used for scoring screening digitized mammograms that were ascertained years prior to diagnosis 1993-2006. Mammographic percent density (PD), using Cumulus, and other major risk factors were...

  5. Anxiety in mammography: mammographers' and clients' perspectives

    International Nuclear Information System (INIS)

    Galletta, S.; Joel, N.; Maguire, R.; Weaver, K.; Poulos, A.

    2003-01-01

    The aim of this study was to identify causes of anxiety experienced by mammographers and clients during mammography and strategies to decrease the anxiety generated by the mammographic procedure. Two questionnaires were distributed: one to mammographers in public and private centres within NSW, the other to women (clients) who have experienced mammography. Mammographers' and clients' rankings of causes of clients' anxiety demonstrated many similarities indicating the mammographers' acknowledgement of factors contributing to client anxiety. Thematic analysis provided important qualitative data concerning anxiety experienced by both mammographers and clients and the influence of mammographer and client behaviour on that anxiety. The results of this study have provided important new knowledge for mammographic practice and mammography education. By understanding the causes of anxiety experienced by clients, mammographers can provide an informed, empathetic approach to the mammographic process. By acknowledging factors which increase their own anxiety mammographers can reduce the impact of this on themselves and on their clients. Copyright (2003) Australian Institute of Radiography

  6. Mammographic features of breast carcinoma: mammographic-pathologic correlation

    International Nuclear Information System (INIS)

    Gu Yajia; Wang Jiuhua; Chen Tongzhen; Zhang Tingqiu; Zhou Kangrong

    2003-01-01

    Objective: To analyze the mammographic features of breast carcinoma and the correlation between the mammographic and pathologic findings. Methods: A prospective study of 397 consecutive mammograms in patients with breast carcinoma, including infiltrating ductal carcinoma (IDC, n=297), ductal carcinoma in situ (DCIS) and DCIS associated with small invasive foci (n=38), mucinous carcinoma (n=21), medullary carcinoma (n=22) and invasive lobular carcinoma (n=19), was performed to determine the correlations between the mammographic and pathologic findings. Results: (1) Microcalcifications appeared in 170 cases (42.8%), a mass in 258 cases (65.0%), and distortion in 33 cases (8.3%), respectively. (2) Microcalcifications were more commonly associated with DCIS and IDC (χ 2 =30.90, P 2 =30.87, P 2 =27.40, P 2 =6.22, P 2 =7.19, P < 0.01). Conclusion: The common features of breast carcinoma in mammography were microcalcifications, microcalcifications with a mass, a mass, and distortion IDC was the commonest in breast carcinoma, and could be considered when mammographic malignant features above mentioned were found except the appearance of microcalcifications alone, which was firstly suggestive of DCIS. A mass also appeared in medullary and mucinous carcinoma, and distortion appeared in invasive lobular carcinoma

  7. Results of pilot project on introducing quality control of mammographic equipment

    International Nuclear Information System (INIS)

    Vasileva, Zh.; Lichev, A.; Dimov, A.; Kostova, E.; Dimov, G.

    2003-01-01

    Objective:The results from a pilot project, realized in the framework of the PHARE Project 'Radiation Protection and Safety in Medical Use of the Ionizing Radiation'. The main goal of the project is the elaboration a quality control program for mammographic equipment and its implementation in 4 radiological units in the country. Another task is to examine the possibility for conducting a mammographic screening using this equipment. Material and methods: The developed quality control program has the following components: test parameters; criteria for intervention; minimal frequency of measurement. Methodologies for measurement of the parameters and assessment of the results in accordance with the European Protocol for physical and technical aspects of the mammographic screening. Standard protocols have been elaborated. Results: The quality program has been tested for three month at different hospitals. Conclusions: Optimization and strict control of the process of film development are needed. The exposure equipment. The quality control program should be implemented on all mammographic equipment in the country. For the performance of mammographic screening a strict selection of the equipment is necessary

  8. Multiscale wavelet representations for mammographic feature analysis

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu

    1992-12-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet coefficients, enhanced by linear, exponential and constant weight functions localized in scale space. By improving the visualization of breast pathology we can improve the changes of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  9. Breast Tissue Composition and Immunophenotype and Its Relationship with Mammographic Density in Women at High Risk of Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Jia-Min B Pang

    Full Text Available To investigate the cellular and immunophenotypic basis of mammographic density in women at high risk of breast cancer.Mammograms and targeted breast biopsies were accrued from 24 women at high risk of breast cancer. Mammographic density was classified into Wolfe categories and ranked by increasing density. The histological composition and immunophenotypic profile were quantified from digitized haematoxylin and eosin-stained and immunohistochemically-stained (ERα, ERβ, PgR, HER2, Ki-67, and CD31 slides and correlated to mammographic density.Increasing mammographic density was significantly correlated with increased fibrous stroma proportion (rs (22 = 0.5226, p = 0.0088 and significantly inversely associated with adipose tissue proportion (rs (22 = -0.5409, p = 0.0064. Contrary to previous reports, stromal expression of ERα was common (19/20 cases, 95%. There was significantly higher stromal PgR expression in mammographically-dense breasts (p=0.026.The proportion of stroma and fat underlies mammographic density in women at high risk of breast cancer. Increased expression of PgR in the stroma of mammographically dense breasts and frequent and unexpected presence of stromal ERα expression raises the possibility that hormone receptor expression in breast stroma may have a role in mediating the effects of exogenous hormonal therapy on mammographic density.

  10. Relationship between breast sound speed and mammographic percent density

    Science.gov (United States)

    Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa

    2011-03-01

    Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.

  11. Improved mammographic interpretation of masses using computer-aided diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Leichter, I. [Dept. of Electro-Optics, Jerusalem College of Technology (Israel); Fields, S.; Novak, B. [Dept. of Radiology, Hadassah University Hospital, Mt. Scopus Jerusalem (Israel); Nirel, R. [Dept. of Statistics, Hebrew University of Jerusalem, Mt. Scopus, Jerusalem (Israel); Bamberger, P. [Dept. of Electronics, Jerusalem College of Technology, Jerusalem (Israel); Lederman, R. [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Buchbinder, S. [Department of Radiology, Montefiore Medical Center, University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States)

    2000-02-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p < 0.005) was found between features extracted by the CAD system for benign and malignant cases. Specificity of the CAD-assisted diagnosis improved significantly (p < 0.02) from 14 % for the conventional assessment to 50 %, and the positive predictive value increased from 0.47 to 0.62 (p < 0.04). The area under the ROC curve (A{sub z}) increased significantly (p < 0.001) from 0.66 for the conventional assessment to 0.81 for the CAD-assisted analysis. The A{sub z} for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that

  12. Mammographic screening programmes in Europe

    DEFF Research Database (Denmark)

    Giordano, Livia; von Karsa, Lawrence; Tomatis, Mariano

    2012-01-01

    To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe.......To summarize participation and coverage rates in population mammographic screening programmes for breast cancer in Europe....

  13. Evaluation Of Digital Unsharp-Mask Filtering For The Detection Of Subtle Mammographic Microcalcifications

    Science.gov (United States)

    Chan, Heang-Ping; Vyborny, Carl J.; MacMahon, Heber; Metz, Charles E.; Doi, Kunio; Sickles, Edward A.

    1986-06-01

    We have conducted a study to assess the effects of digitization and unsharp-mask filtering on the ability of observers to detect subtle microcalcifications in mammograms. Thirty-two conventional screen-film mammograms were selected from patient files by two experienced mammographers. Twelve of the mammograms contained a suspicious cluster of microcalcifications in patients who subsequently underwent biopsy. Twenty of the mammograms were normal cases which were initially interpreted as being free of clustered microcalcifications and did not demonstrate such on careful review. The mammograms were digitized with a high-quality Fuji image processing/simulation system. The system consists of two drum scanners with which an original radiograph can be digitized, processed by a minicomputer, and reconstituted on film. In this study, we employed a sampling aperture of 0.1 mm X 0.1 mm and a sampling distance of 0.1 mm. The density range from 0.2 to 2.75 was digitized to 1024 grey levels per pixel. The digitized images were printed on a single emulsion film with a display aperture having the same size as the sampling aperture. The system was carefully calibrated so that the density and contrast of a digitized image were closely matched to those of the original radiograph. Initially, we evaluated the effects of the weighting factor and the mask size of a unsharp-mask filter on the appearance of mammograms for various types of breasts. Subjective visual comparisons suggested that a mask size of 91 X 91 pixels (9.1 mm X 9.1 mm) enhances the visibility of microcalcifications without excessively increasing the high-frequency noise. Further, a density-dependent weighting factor that increases linearly from 1.5 to 3.0 in the density range of 0.2 to 2.5 enhances the contrast of microcalcifications without introducing many potentially confusing artifacts in the low-density areas. An unsharp-mask filter with these parameters was used to process the digitized mammograms. We conducted

  14. Mammographic scar for stereotaxic biopsy

    International Nuclear Information System (INIS)

    Guzman Tattis; Hincapie U, Ana Lucia; Patino P, Jairo Hernando

    1997-01-01

    It is reported the case of 56 years old woman who underwent a stereotactic biopsy because of having a circumscribed breast nodule. The histologic diagnosis was benign. After six months, during the mammographic control, it was noticed that the nodule showed irregular contours, because of that a surgical biopsy was performed. The histopathology was reported as benign. it is considered then, that the mammographic changes observed in the mammographic control are due to scar phenomenon after stereotactic biopsy. This findings has not been reported previously

  15. Mammographic surveillance in the follow up of early primary breast cancer in England: A cross-sectional survey

    International Nuclear Information System (INIS)

    Greenwood-Haigh, Lesley

    2009-01-01

    Purpose: The aim of this study was to determine current practice in the clinical setting at national and regional level of the use of mammographic surveillance in the follow up of patients surgically treated for early breast cancer. Method: A cross-sectional survey method was employed. Self-administered questionnaires were sent to a random selection of symptomatic breast imaging units representing all the cancer networks in England nationally, and all symptomatic breast imaging units in one cancer network regionally. Questions were designed to determine frequency and duration of mammographic surveillance for patients aged < 50 years and ≥50 years surgically treated by mastectomy or breast conserving surgery and the number of units with protocols based on the risk of local recurrence or development of a new primary breast cancer. Results: The protocols demonstrated a striking diversity in both the frequency and duration of mammographic surveillance; however the variation was less marked regionally. The duration of mammography for patient's aged ≥70 years surgically treated by mastectomy, demonstrated the greatest diversity (range: 0-15 years). Four protocols had regimes tailored to risk. Conclusion: The introduction of protocols based on risk of development of a local recurrence or new primary could prove cost effective by targeting mammographic surveillance to those who would benefit the most. The survey has demonstrated that a 'post-code lottery' exists for both the frequency and duration of mammographic surveillance in this patient group indicating an urgent need for evidence based national guidance.

  16. Ultrasound detection of nonpalpable mammographically occult malignancy

    International Nuclear Information System (INIS)

    Simpson, W.L.; Hermann, G.; Rausch, D.R.; Sherman, J.; Feig, S.A.; Bleiweiss, I.J.; Jaffer, S.

    2008-01-01

    To evaluate the prevalence of occult malignancy with screening breast ultrasound. All ultrasound-guided core needle breast biopsies performed between January 1, 1999, and June 30, 2001, were retrospectively reviewed. Lesions were identified during screening breast ultrasound in high-risk women with no mammographic or palpable abnormality in either breast, a unilateral mammographic or palpable abnormality in the contralateral breast, or a unilateral mammographic or palpable abnormality in a different quadrant of the same breast. All ultrasound-detected lesions were histologically verified. Six hundred and fifty-two women with a mean age of 49 years underwent 698 biopsies during the study period. Three hundred and forty-nine of these lesions were detected at screening breast ultrasound. Out of 349, 11 (3.2%) had a mammographically and clinically occult malignancy. Nine cancers were found in women with no mammographic or palpable abnormality. Two cancers were found in the same breast as the mammographic or palpable abnormality. None were found in the breast contralateral to a palpable or mammographic abnormality. Screening breast ultrasound of high-risk women has a similar detection rate for occult carcinoma as screening mammography, but has a low positive predictive value in cases where biopsy is performed. (author)

  17. Ethnicity, Soybean Consumption, and Mammographic Densities

    National Research Council Canada - National Science Library

    Maskarinec, Gertraud

    1997-01-01

    The purpose of this study is to determine whether mammographic density patterns differ by ethnic background and to explore the possible association of a soy rich diet with mammographic density patterns...

  18. Malignant Lesions as Mammographically Appearing Intramammary Ganglia

    International Nuclear Information System (INIS)

    Martinez-Miraveta, P.; Pons, M. J.; Pina, L. J.; Zornoza, G.

    2004-01-01

    Intramammary ganglia are frequent mammographic findings of no pathological importance. We present two cases of malignant breast lesions whose mammographic appearance could resemble that of intramammary ganglia. Although the mammographic appearance of a lesion is similar to that of intramammary ganglia, it should be carefully studied, especially if it presents a poorly defined border or is palpable. (Author)

  19. Mammographic appearances of male breast disease.

    Science.gov (United States)

    Appelbaum, A H; Evans, G F; Levy, K R; Amirkhan, R H; Schumpert, T D

    1999-01-01

    Various male breast diseases have characteristic mammographic appearances that can be correlated with their pathologic diagnoses. Male breast cancer is usually subareolar and eccentric to the nipple. Margins of the lesions are more frequently well defined, and calcifications are rarer and coarser than those occurring in female breast cancer. Gynecomastia usually appears as a fan-shaped density emanating from the nipple, gradually blending into surrounding fat. It may have prominent extensions into surrounding fat and, in some cases, an appearance similar to that of a heterogeneously dense female breast. Although there are characteristic mammographic features that allow breast cancer in men to be recognized, there is substantial overlap between these features and the mammographic appearance of benign nodular lesions. The mammographic appearance of gynecomastia is not similar to that of male breast cancer, but in rare cases, it can mask malignancy. Gynecomastia can be mimicked by chronic inflammation. All mammographically lucent lesions of the male breast appear to be benign, similar to such lesions in the female breast.

  20. Mammographic compression in Asian women.

    Science.gov (United States)

    Lau, Susie; Abdul Aziz, Yang Faridah; Ng, Kwan Hoong

    2017-01-01

    To investigate: (1) the variability of mammographic compression parameters amongst Asian women; and (2) the effects of reducing compression force on image quality and mean glandular dose (MGD) in Asian women based on phantom study. We retrospectively collected 15818 raw digital mammograms from 3772 Asian women aged 35-80 years who underwent screening or diagnostic mammography between Jan 2012 and Dec 2014 at our center. The mammograms were processed using a volumetric breast density (VBD) measurement software (Volpara) to assess compression force, compression pressure, compressed breast thickness (CBT), breast volume, VBD and MGD against breast contact area. The effects of reducing compression force on image quality and MGD were also evaluated based on measurement obtained from 105 Asian women, as well as using the RMI156 Mammographic Accreditation Phantom and polymethyl methacrylate (PMMA) slabs. Compression force, compression pressure, CBT, breast volume, VBD and MGD correlated significantly with breast contact area (pAsian women. The median compression force should be about 8.1 daN compared to the current 12.0 daN. Decreasing compression force from 12.0 daN to 9.0 daN increased CBT by 3.3±1.4 mm, MGD by 6.2-11.0%, and caused no significant effects on image quality (p>0.05). Force-standardized protocol led to widely variable compression parameters in Asian women. Based on phantom study, it is feasible to reduce compression force up to 32.5% with minimal effects on image quality and MGD.

  1. The combined effect of mammographic texture and density on breast cancer risk: a cohort study.

    Science.gov (United States)

    Wanders, Johanna O P; van Gils, Carla H; Karssemeijer, Nico; Holland, Katharina; Kallenberg, Michiel; Peeters, Petra H M; Nielsen, Mads; Lillholm, Martin

    2018-05-02

    Texture patterns have been shown to improve breast cancer risk segregation in addition to area-based mammographic density. The additional value of texture pattern scores on top of volumetric mammographic density measures in a large screening cohort has never been studied. Volumetric mammographic density and texture pattern scores were assessed automatically for the first available digital mammography (DM) screening examination of 51,400 women (50-75 years of age) participating in the Dutch biennial breast cancer screening program between 2003 and 2011. The texture assessment method was developed in a previous study and validated in the current study. Breast cancer information was obtained from the screening registration system and through linkage with the Netherlands Cancer Registry. All screen-detected breast cancers diagnosed at the first available digital screening examination were excluded. During a median follow-up period of 4.2 (interquartile range (IQR) 2.0-6.2) years, 301 women were diagnosed with breast cancer. The associations between texture pattern scores, volumetric breast density measures and breast cancer risk were determined using Cox proportional hazard analyses. Discriminatory performance was assessed using c-indices. The median age of the women at the time of the first available digital mammography examination was 56 years (IQR 51-63). Texture pattern scores were positively associated with breast cancer risk (hazard ratio (HR) 3.16 (95% CI 2.16-4.62) (p value for trend <0.001), for quartile (Q) 4 compared to Q1). The c-index of texture was 0.61 (95% CI 0.57-0.64). Dense volume and percentage dense volume showed positive associations with breast cancer risk (HR 1.85 (95% CI 1.32-2.59) (p value for trend <0.001) and HR 2.17 (95% CI 1.51-3.12) (p value for trend <0.001), respectively, for Q4 compared to Q1). When adding texture measures to models with dense volume or percentage dense volume, c-indices increased from 0.56 (95% CI 0.53-0.59) to 0

  2. Association of mammographic image feature change and an increasing risk trend of developing breast cancer: an assessment

    Science.gov (United States)

    Tan, Maxine; Leader, Joseph K.; Liu, Hong; Zheng, Bin

    2015-03-01

    We recently investigated a new mammographic image feature based risk factor to predict near-term breast cancer risk after a woman has a negative mammographic screening. We hypothesized that unlike the conventional epidemiology-based long-term (or lifetime) risk factors, the mammographic image feature based risk factor value will increase as the time lag between the negative and positive mammography screening decreases. The purpose of this study is to test this hypothesis. From a large and diverse full-field digital mammography (FFDM) image database with 1278 cases, we collected all available sequential FFDM examinations for each case including the "current" and 1 to 3 most recently "prior" examinations. All "prior" examinations were interpreted negative, and "current" ones were either malignant or recalled negative/benign. We computed 92 global mammographic texture and density based features, and included three clinical risk factors (woman's age, family history and subjective breast density BIRADS ratings). On this initial feature set, we applied a fast and accurate Sequential Forward Floating Selection (SFFS) feature selection algorithm to reduce feature dimensionality. The features computed on both mammographic views were individually/ separately trained using two artificial neural network (ANN) classifiers. The classification scores of the two ANNs were then merged with a sequential ANN. The results show that the maximum adjusted odds ratios were 5.59, 7.98, and 15.77 for using the 3rd, 2nd, and 1st "prior" FFDM examinations, respectively, which demonstrates a higher association of mammographic image feature change and an increasing risk trend of developing breast cancer in the near-term after a negative screening.

  3. Pilot study of intraoperative digital imaging with the use of a mammograph for assessment of bone surgical margins in the head and neck region

    International Nuclear Information System (INIS)

    Ntomouchtsis, A.; Xinou, K.; Patrikidou, A.; Paraskevopoulos, K.; Kechagias, N.; Tsekos, A.; Balis, G.C.; Gerasimidou, D.; Thuau, H.; Mangoudi, D.; Vahtsevanos, K.

    2013-01-01

    Aim: To investigate alternative possibilities for the intraoperative evaluation of surgical margins after bone resection utilizing more conventional hospital infrastructure technologies. Materials and methods: A small pilot study was performed using digital mammograph imaging intraoperatively on 16 surgical specimens of bone tumours or malignancies with bone infiltration of the head and neck area, with the aim of evaluating the resection margins. Results: In thirteen cases the intraoperative specimen images indicated clinically complete excision. In two cases incomplete resection or close proximity of margins was detected, which required additional resection. Conclusions: The results indicated that intraoperative specimen radiography can prove useful in evaluating completeness of excision. The significance of intraoperative assessment of surgical margin is of paramount importance when immediate reconstruction is performed. This proposed method is cheap, easy to perform and fast. Its cost–benefit ratio is superior than that of any other available technique. Intraoperative analysis of specimens with digital mammography imaging can potentially become a useful tool for immediate evaluation of osseous margins after resection

  4. Nonpalpable breast cancer : mammographic and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-08-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group.

  5. Nonpalpable breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan

    1998-01-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group

  6. A uniform system for mammographic reporting BI-RADS

    International Nuclear Information System (INIS)

    Masroor, I.; Ahmad, M. N.; Sheikh, M. Y.

    2001-01-01

    Breast image reporting and data system (BI-RADS) is a new system of categorizing and reporting mammographs and mammographic findings recommended by American College of Radiology. The importance of BI-RADS and final assessment categories are discussed. The purpose is to introduce the above-mentioned mammographic reporting system so that it becomes a standard terminology among the medical personnel, involved in the diagnosis and management of breast diseases. (author)

  7. Epidemiologic Studies of Isoflavones & Mammographic Density

    Science.gov (United States)

    Maskarinec, Gertraud; Verheus, Martijn; Tice, Jeffrey A.

    2010-01-01

    Isoflavones, phytoestrogens in soy beans with estrogen-like properties, have been examined for their cancer protective effects. Mammographic density is a strong predictor of breast cancer. This review summarizes studies that have examined the association between isoflavones and breast density. Observational investigations in Hawaii and Singapore suggest slightly lower breast density among women of Asian descent with regular soy intake, but two larger studies from Japan and Singapore did not observe a protective effect. The findings from seven randomized trials with primarily Caucasian women indicate that soy or isoflavones do not modify mammographic density. Soy foods and isoflavone supplements within a nutritional range do not appear to modify breast cancer risk as assessed by mammographic density. PMID:22253990

  8. Epidemiologic Studies of Isoflavones & Mammographic Density

    Directory of Open Access Journals (Sweden)

    Jeffrey A. Tice

    2010-01-01

    Full Text Available Isoflavones, phytoestrogens in soy beans with estrogen-like properties, have been examined for their cancer protective effects. Mammographic density is a strong predictor of breast cancer. This review summarizes studies that have examined the association between isoflavones and breast density. Observational investigations in Hawaii and Singapore suggest slightly lower breast density among women of Asian descent with regular soy intake, but two larger studies from Japan and Singapore did not observe a protective effect. The findings from seven randomized trials with primarily Caucasian women indicate that soy or isoflavones do not modify mammographic density. Soy foods and isoflavone supplements within a nutritional range do not appear to modify breast cancer risk as assessed by mammographic density.

  9. Stratification of mammographic computerized analysis by BI-RADS categories

    International Nuclear Information System (INIS)

    Lederman, Richard; Leichter, Isaac; Buchbinder, Shalom; Novak, Boris; Bamberger, Philippe; Fields, Scott

    2003-01-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A z of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A z of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A z significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  10. Development of terminology for mammographic techniques for radiological technologists.

    Science.gov (United States)

    Yagahara, Ayako; Yokooka, Yuki; Tsuji, Shintaro; Nishimoto, Naoki; Uesugi, Masahito; Muto, Hiroshi; Ohba, Hisateru; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2011-07-01

    We are developing a mammographic ontology to share knowledge of the mammographic domain for radiologic technologists, with the aim of improving mammographic techniques. As a first step in constructing the ontology, we used mammography reference books to establish mammographic terminology for identifying currently available knowledge. This study proceeded in three steps: (1) determination of the domain and scope of the terminology, (2) lexical extraction, and (3) construction of hierarchical structures. We extracted terms mainly from three reference books and constructed the hierarchical structures manually. We compared features of the terms extracted from the three reference books. We constructed a terminology consisting of 440 subclasses grouped into 19 top-level classes: anatomic entity, image quality factor, findings, material, risk, breast, histological classification of breast tumors, role, foreign body, mammographic technique, physics, purpose of mammography examination, explanation of mammography examination, image development, abbreviation, quality control, equipment, interpretation, and evaluation of clinical imaging. The number of terms that occurred in the subclasses varied depending on which reference book was used. We developed a terminology of mammographic techniques for radiologic technologists consisting of 440 terms.

  11. Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Samei, Ehsan; Saunders, Robert; Abbey, Craig; Delong, David

    2007-01-01

    The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures

  12. Stratification of mammographic computerized analysis by BI-RADS categories

    Energy Technology Data Exchange (ETDEWEB)

    Lederman, Richard [Department of Radiology, Hadassah University Hospital, Ein Kerem, Jerusalem (Israel); Leichter, Isaac [Department of Electro-Optics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem (Israel); Buchbinder, Shalom [Department of Radiology of The Montefiore Medical Center, The University Hospital for the Albert Einstein College of Medicine, Bronx, New York (United States); Novak, Boris [Department of Applied Mathematics, Jerusalem College of Technology, P.O.B. 16031, Jerusalem 91160 (Israel); Bamberger, Philippe [Department of Electronics, Jerusalem College of Technology, POB 16031, Jerusalem (Israel); Fields, Scott [Department of Radiology, Hadassah University Hospital, Mt. Scopus, Jerusalem (Israel)

    2003-02-01

    The Breast Imaging Reporting and Data System (BI-RADS) was implemented to standardize characterization of mammographic findings. The purpose of the present study was to evaluate in which BI-RADS categories the changes recommended by computerized mammographic analysis are most beneficial. Archival cases including, 170 masses (101 malignant, 69 benign) and 63 clusters of microcalcifications (MCs; 36 malignant, 27 benign), were evaluated retrospectively, using the BI-RADS categories, by several radiologists, blinded to the pathology results. A computerized system then automatically extracted from the digitized mammogram features characterizing mammographic lesions, which were used to classify the lesions. The results of the computerized classification scheme were compared, by receiver operating characteristics (ROC) analysis, to the conventional interpretation. In the ''low probability of malignancy group'' (excluding BI-RADS categories 4 and 5), computerized analysis improved the A{sub z}of the ROC curve significantly, from 0.57 to 0.89. In the ''high probability of malignancy group'' (mostly category 5) the computerized analysis yielded an ROC curve with an A {sub z}of 0.99. In the ''intermediate probability of malignancy group'' computerized analysis improved the A {sub z}significantly, from 0.66 for to 0.83. Pair-wise analysis showed that in the latter group the modifications resulting from computerized analysis were correct in 83% of cases. Computerized analysis has the ability to improve the performance of the radiologists exactly in the BI-RADS categories with the greatest difficulties in arriving at a correct diagnosis. It increased the performance significantly in the problematic group of ''intermediate probability of malignancy'' and pinpointed all the cases with missed cancers in the ''low probability'' group. (orig.)

  13. State supervision of SONS in the mammographic departments

    International Nuclear Information System (INIS)

    Jursikova, E.; Kodl, O.

    2008-01-01

    State Office for Nuclear Safety has been performed the state supervision over radiation protection at all mammographic centres in the Czech Republic. Inspections are carried out on the basis of requirements of: Act No. 18/1997 Coll., Atomic Act, subsequently amended; Act No. 552/1991 Coll., Supervision Act, subsequently amended; Decree No. 307 /2002 Coll., On radiation protection, as amended by Decree No. 499/2005 Coll. 137 mammography X-ray units have been used actively by 108 independent licensees since 1 September 2008. The mammography screening program started in September 2002. The screening program was carried out at 59 working places last year and already at 66 workplaces with accreditation from 1 up to 3 years this year. The activity of the centres is monitored and inspected continuously (not only by SONS). Inspections at 35 workplaces were carried out last year .The doses are significantly below guidance levels at major part of working places. Most of detected defects were eliminated after inspections. The quality of mammographic workplaces in the Czech Republic has been gradually increased and improved. (authors)

  14. Textural Classification of Mammographic Parenchymal Patterns with the SONNET Selforganizing Neural Network

    Directory of Open Access Journals (Sweden)

    Daniel Howard

    2008-01-01

    Full Text Available In nationwide mammography screening, thousands of mammography examinations must be processed. Each consists of two standard views of each breast, and each mammogram must be visually examined by an experienced radiologist to assess it for any anomalies. The ability to detect an anomaly in mammographic texture is important to successful outcomes in mammography screening and, in this study, a large number of mammograms were digitized with a highly accurate scanner; and textural features were derived from the mammograms as input data to a SONNET selforganizing neural network. The paper discusses how SONNET was used to produce a taxonomic organization of the mammography archive in an unsupervised manner. This process is subject to certain choices of SONNET parameters, in these numerical experiments using the craniocaudal view, and typically produced O(10, for example, 39 mammogram classes, by analysis of features from O(103 mammogram images. The mammogram taxonomy captured typical subtleties to discriminate mammograms, and it is submitted that this may be exploited to aid the detection of mammographic anomalies, for example, by acting as a preprocessing stage to simplify the task for a computational detection scheme, or by ordering mammography examinations by mammogram taxonomic class prior to screening in order to encourage more successful visual examination during screening. The resulting taxonomy may help train screening radiologists and conceivably help to settle legal cases concerning a mammography screening examination because the taxonomy can reveal the frequency of mammographic patterns in a population.

  15. Serum osteoprotegerin levels and mammographic density among high-risk women.

    Science.gov (United States)

    Moran, Olivia; Zaman, Tasnim; Eisen, Andrea; Demsky, Rochelle; Blackmore, Kristina; Knight, Julia A; Elser, Christine; Ginsburg, Ophira; Zbuk, Kevin; Yaffe, Martin; Narod, Steven A; Salmena, Leonardo; Kotsopoulos, Joanne

    2018-06-01

    Mammographic density is a risk factor for breast cancer but the mechanism behind this association is unclear. The receptor activator of nuclear factor κB (RANK)/RANK ligand (RANKL) pathway has been implicated in the development of breast cancer. Given the role of RANK signaling in mammary epithelial cell proliferation, we hypothesized this pathway may also be associated with mammographic density. Osteoprotegerin (OPG), a decoy receptor for RANKL, is known to inhibit RANK signaling. Thus, it is of interest to evaluate whether OPG levels modify breast cancer risk through mammographic density. We quantified serum OPG levels in 57 premenopausal and 43 postmenopausal women using an enzyme-linked immunosorbent assay (ELISA). Cumulus was used to measure percent density, dense area, and non-dense area for each mammographic image. Subjects were classified into high versus low OPG levels based on the median serum OPG level in the entire cohort (115.1 pg/mL). Multivariate models were used to assess the relationship between serum OPG levels and the measures of mammographic density. Serum OPG levels were not associated with mammographic density among premenopausal women (P ≥ 0.42). Among postmenopausal women, those with low serum OPG levels had higher mean percent mammographic density (20.9% vs. 13.7%; P = 0.04) and mean dense area (23.4 cm 2 vs. 15.2 cm 2 ; P = 0.02) compared to those with high serum OPG levels after covariate adjustment. These findings suggest that low OPG levels may be associated with high mammographic density, particularly in postmenopausal women. Targeting RANK signaling may represent a plausible, non-surgical prevention option for high-risk women with high mammographic density, especially those with low circulating OPG levels.

  16. Mass Detection in Mammographic Images Using Wavelet Processing and Adaptive Threshold Technique.

    Science.gov (United States)

    Vikhe, P S; Thool, V R

    2016-04-01

    Detection of mass in mammogram for early diagnosis of breast cancer is a significant assignment in the reduction of the mortality rate. However, in some cases, screening of mass is difficult task for radiologist, due to variation in contrast, fuzzy edges and noisy mammograms. Masses and micro-calcifications are the distinctive signs for diagnosis of breast cancer. This paper presents, a method for mass enhancement using piecewise linear operator in combination with wavelet processing from mammographic images. The method includes, artifact suppression and pectoral muscle removal based on morphological operations. Finally, mass segmentation for detection using adaptive threshold technique is carried out to separate the mass from background. The proposed method has been tested on 130 (45 + 85) images with 90.9 and 91 % True Positive Fraction (TPF) at 2.35 and 2.1 average False Positive Per Image(FP/I) from two different databases, namely Mammographic Image Analysis Society (MIAS) and Digital Database for Screening Mammography (DDSM). The obtained results show that, the proposed technique gives improved diagnosis in the early breast cancer detection.

  17. Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.

    Science.gov (United States)

    Rosado-Méndez, I; Palma, B A; Brandan, M E

    2008-12-01

    Contrast-medium-enhanced digital mammography (CEDM) is an image subtraction technique which might help unmasking lesions embedded in very dense breasts. Previous works have stated the feasibility of CEDM and the imperative need of radiological optimization. This work presents an extension of a former analytical formalism to predict contrast-to-noise ratio (CNR) in subtracted mammograms. The goal is to optimize radiological parameters available in a clinical mammographic unit (x-ray tube anode/filter combination, voltage, and loading) by maximizing CNR and minimizing total mean glandular dose (D(gT)), simulating the experimental application of an iodine-based contrast medium and the image subtraction under dual-energy nontemporal, and single- or dual-energy temporal modalities. Total breast-entrance air kerma is limited to a fixed 8.76 mGy (1 R, similar to screening studies). Mathematical expressions obtained from the formalism are evaluated using computed mammographic x-ray spectra attenuated by an adipose/glandular breast containing an elongated structure filled with an iodinated solution in various concentrations. A systematic study of contrast, its associated variance, and CNR for different spectral combinations is performed, concluding in the proposal of optimum x-ray spectra. The linearity between contrast in subtracted images and iodine mass thickness is proven, including the determination of iodine visualization limits based on Rose's detection criterion. Finally, total breast-entrance air kerma is distributed between both images in various proportions in order to maximize the figure of merit CNR2/D(gT). Predicted results indicate the advantage of temporal subtraction (either single- or dual-energy modalities) with optimum parameters corresponding to high-voltage, strongly hardened Rh/Rh spectra. For temporal techniques, CNR was found to depend mostly on the energy of the iodinated image, and thus reduction in D(gT) could be achieved if the spectral energy

  18. Accuracy and reading time for six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts.

    Science.gov (United States)

    Tagliafico, Alberto Stefano; Calabrese, Massimo; Bignotti, Bianca; Signori, Alessio; Fisci, Erica; Rossi, Federica; Valdora, Francesca; Houssami, Nehmat

    2017-12-01

    To compare six strategies using digital breast tomosynthesis in women with mammographically negative dense breasts. This is a substudy of the 'ASTOUND' trial. 163 women who underwent tomosynthesis with synthetically reconstructed projection images (S-2D) inclusive of 13 (7.9%) cases diagnosed with breast cancer at histopathology after surgery were evaluated. Accuracy measures and screen-reading time of six reading strategies were assessed: (A) Single reading of S-2D alone, (B) single reading of tomosynthesis alone, (C) single reading of joint interpretation of tomosynthesis + S-2D, (D) double-reading of S-2D alone, (E) double reading of tomosynthesis alone, (F) double reading of joint interpretation of tomosynthesis + S-2D. The median age of the patients was 53 years (range, 36-88 years). The highest global accuracy was obtained with double reading of tomosynthesis + S2D (F) with an AUC of 0.979 (ptomosynthesis+ S2D had the best accuracy of six screen-reading strategies although it had the longest reading time. • Tomosynthesis acquisitions are progressively implemented with reconstructed synthesized 2D images • Double reading using S-2D plus tomosynthesis had the highest global accuracy (ptomosynthesis increased reading time.

  19. Mammographic texture resemblance generalizes as an independent risk factor for breast cancer

    DEFF Research Database (Denmark)

    Nielsen, Mads; Vachon, Celine M.; Scott, Christopher G.

    2014-01-01

    INTRODUCTION:Breast density has been established as a major risk factor for breast cancer. We have previously demonstrated that mammographic texture resemblance (MTR), recognizing the local texture patterns of the mammogram, is also a risk factor for breast cancer, independent of percent breast...... density. We examine if these findings generalize to another population.METHODS:Texture patterns were recorded in digitalized pre-diagnosis (3.7years) film mammograms of a nested case-control study within the Dutch screening program (S1) comprising of 245 breast cancers and 250 matched controls...

  20. Occupation and mammographic density: A population-based study (DDM-Occup).

    Science.gov (United States)

    García-Pérez, Javier; Pollán, Marina; Pérez-Gómez, Beatriz; González-Sánchez, Mario; Cortés Barragán, Rosa Ana; Maqueda Blasco, Jerónimo; González-Galarzo, María Carmen; Alba, Miguel Ángel; van der Haar, Rudolf; Casas, Silvia; Vicente, Cándida; Medina, Pilar; Ederra, María; Santamariña, Carmen; Moreno, María Pilar; Casanova, Francisco; Pedraz-Pingarrón, Carmen; Moreo, Pilar; Ascunce, Nieves; García, Montse; Salas-Trejo, Dolores; Sánchez-Contador, Carmen; Llobet, Rafael; Lope, Virginia

    2017-11-01

    High mammographic density is one of the main risk factors for breast cancer. Although several occupations have been associated with breast cancer, there are no previous occupational studies exploring the association with mammographic density. Our objective was to identify occupations associated with high mammographic density in Spanish female workers. We conducted a population-based cross-sectional study of occupational determinants of high mammographic density in Spain, based on 1476 women, aged 45-68 years, recruited from seven screening centers within the Spanish Breast Cancer Screening Program network. Reproductive, family, personal, and occupational history data were collected. The latest occupation of each woman was collected and coded according to the 1994 National Classification of Occupations. Mammographic density was assessed from the cranio-caudal mammogram of the left breast using a semi-automated computer-assisted tool. Association between mammographic density and occupation was evaluated by using mixed linear regression models, using log-transformed percentage of mammographic density as dependent variable. Models were adjusted for age, body mass index, menopausal status, parity, smoking, alcohol intake, educational level, type of mammography, first-degree relative with breast cancer, and hormonal replacement therapy use. Screening center and professional reader were included as random effects terms. Mammographic density was higher, although non-statistically significant, among secondary school teachers (e β = 1.41; 95%CI = 0.98-2.03) and nurses (e β = 1.23; 95%CI = 0.96-1.59), whereas workers engaged in the care of people (e β = 0.81; 95%CI = 0.66-1.00) and housewives (e β = 0.87; 95%CI = 0.79-0.95) showed an inverse association with mammographic density. A positive trend for every 5 years working as secondary school teachers was also detected (p-value = 0.035). Nurses and secondary school teachers were the occupations with the highest

  1. Changes in mammographic density and breast cancer risk

    NARCIS (Netherlands)

    Lokate, A.J.M.

    2012-01-01

    Breast cancer is the most frequently occurring cancer among women worldwide. One of the most important risk factors for breast cancer is high mammographic density. Mammographic density represents the amount of fibroglandular tissue relative to the fat tissue in the breast. Women with >75% of their

  2. Clinical evaluation of JPEG2000 compression for digital mammography

    Science.gov (United States)

    Sung, Min-Mo; Kim, Hee-Joung; Kim, Eun-Kyung; Kwak, Jin-Young; Yoo, Jae-Kyung; Yoo, Hyung-Sik

    2002-06-01

    Medical images, such as computed radiography (CR), and digital mammographic images will require large storage facilities and long transmission times for picture archiving and communications system (PACS) implementation. American College of Radiology and National Equipment Manufacturers Association (ACR/NEMA) group is planning to adopt a JPEG2000 compression algorithm in digital imaging and communications in medicine (DICOM) standard to better utilize medical images. The purpose of the study was to evaluate the compression ratios of JPEG2000 for digital mammographic images using peak signal-to-noise ratio (PSNR), receiver operating characteristic (ROC) analysis, and the t-test. The traditional statistical quality measures such as PSNR, which is a commonly used measure for the evaluation of reconstructed images, measures how the reconstructed image differs from the original by making pixel-by-pixel comparisons. The ability to accurately discriminate diseased cases from normal cases is evaluated using ROC curve analysis. ROC curves can be used to compare the diagnostic performance of two or more reconstructed images. The t test can be also used to evaluate the subjective image quality of reconstructed images. The results of the t test suggested that the possible compression ratios using JPEG2000 for digital mammographic images may be as much as 15:1 without visual loss or with preserving significant medical information at a confidence level of 99%, although both PSNR and ROC analyses suggest as much as 80:1 compression ratio can be achieved without affecting clinical diagnostic performance.

  3. Comparison of Danish dichotomous and BI-RADS classifications of mammographic density.

    Science.gov (United States)

    Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My; Vejborg, Ilse; Andersen, Zorana Jovanovic

    2014-06-01

    In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. To compare the Danish dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. Of the 120 women, 32 (26.7%) were classified as having fatty and 88 (73.3%) as mixed/dense mammographic density, according to Danish dichotomous classification. According to BI-RADS density classification, 12 (10.0%) women were classified as having predominantly fatty (BI-RADS code 1), 46 (38.3%) as having scattered fibroglandular (BI-RADS code 2), 57 (47.5%) as having heterogeneously dense (BI-RADS 3), and five (4.2%) as having extremely dense (BI-RADS code 4) mammographic density. The inter-rater variability assessed by weighted kappa statistic showed a substantial agreement (0.75). The dichotomous mammographic density classification system utilized in early years of Copenhagen's mammographic screening program (1991-2001) agreed well with the BI-RADS density classification system.

  4. Experimental test of a new technique of background suppression in digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, M.G.; Bottari, S.; Ciocci, M.A.; Fantacci, M.E.; Maestro, P.; Malakhov, N.; Marrocchesi, P.S. E-mail: marrocchesi@pi.infn.it; Novelli, M.; Quattrocchi, M.; Pilo, F.; Rosso, V.; Turini, N.; Zucca, S

    2002-02-01

    A multiple-exposure technique in digital mammography has been developed to suppress the physical background in the image due to Compton scattering in the body. A pair of X-ray masks, shaped in a projective geometry and positioned upstream and downstream the patient, are coupled mechanically and moved in four steps along a square pattern in order to irradiate the full area in four consecutive short exposures. A proof-of-principle apparatus is under test with a breast phantom and a standard mammographic X-ray unit. Results are reported.

  5. Experimental test of a new technique of background suppression in digital mammography

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Bottari, S.; Ciocci, M.A.; Fantacci, M.E.; Maestro, P.; Malakhov, N.; Marrocchesi, P.S.; Novelli, M.; Quattrocchi, M.; Pilo, F.; Rosso, V.; Turini, N.; Zucca, S.

    2002-01-01

    A multiple-exposure technique in digital mammography has been developed to suppress the physical background in the image due to Compton scattering in the body. A pair of X-ray masks, shaped in a projective geometry and positioned upstream and downstream the patient, are coupled mechanically and moved in four steps along a square pattern in order to irradiate the full area in four consecutive short exposures. A proof-of-principle apparatus is under test with a breast phantom and a standard mammographic X-ray unit. Results are reported

  6. Posterior breast cancer: Mammographic and ultrasonographic features

    Directory of Open Access Journals (Sweden)

    Janković Ana

    2013-01-01

    Full Text Available Background/Aim. Posterior breast cancers are located in the prepectoral region of the breast. Owing to this distinctive anatomical localization, physical examination and mammographic or ultrasonographic evaluation can be difficult. The purpose of the study was to assess possibilities of diagnostic mammography and breast ultrasonography in detection and differentiation of posterior breast cancers. Methods. The study included 40 women with palpable, histopathological confirmed posterior breast cancer. Mammographic and ultrasonographic features were defined according to Breast Imaging Reporting and Data System (BI-RADS lexicon. Results. Based on standard two-view mammography 87.5%, of the cases were classified as BI-RADS 4 and 5 categories, while after additional mammographic views all the cases were defined as BIRADS 4 and 5 categories. Among 96 mammographic descriptors, the most frequent were: spiculated mass (24.0%, architectural distortion (16.7%, clustered microcalcifications (12.6% and focal asymmetric density (12.6%. The differentiation of the spiculated mass was significantly associated with the possibility to visualize the lesion at two-view mammography (p = 0.009, without the association with lesion diameter (p = 0.083 or histopathological type (p = 0.055. Mammographic signs of invasive lobular carcinoma were significantly different from other histopathological types (architectural distortion, p = 0.003; focal asymmetric density, p = 0.019; association of four or five subtle signs of malignancy, p = 0.006. All cancers were detectable by ultrasonography. Mass lesions were found in 82.0% of the cases. Among 153 ultrasonographic descriptors, the most frequent were: irregular mass (15.7%, lobulated mass (7.2%, abnormal color Doppler signals (20.3%, posterior acoustic attenuation (18.3%. Ultrasonographic BI-RADS 4 and 5 categories were defined in 72.5% of the cases, without a significant difference among various histopathological types (p = 0

  7. Cone-beam volume CT mammographic imaging: feasibility study

    Science.gov (United States)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  8. Spatial recurrence analysis: A sensitive and fast detection tool in digital mammography

    International Nuclear Information System (INIS)

    Prado, T. L.; Galuzio, P. P.; Lopes, S. R.; Viana, R. L.

    2014-01-01

    Efficient diagnostics of breast cancer requires fast digital mammographic image processing. Many breast lesions, both benign and malignant, are barely visible to the untrained eye and requires accurate and reliable methods of image processing. We propose a new method of digital mammographic image analysis that meets both needs. It uses the concept of spatial recurrence as the basis of a spatial recurrence quantification analysis, which is the spatial extension of the well-known time recurrence analysis. The recurrence-based quantifiers are able to evidence breast lesions in a way as good as the best standard image processing methods available, but with a better control over the spurious fragments in the image

  9. Image enhancement by using IDL for a mammographic x-ray image in Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Md Saion Salikin; Wan Hazlinda Ismail; Norriza Mohd Isa; Azuhar Ripin

    2004-01-01

    Digital image enhancement technique can have a significant impact on the diagnostic quality of a radiographic image. The main aim of image enhancement is to process the image so that the enhanced image is clearer and more useful for specific application. There are three types of image enhancement namely noise reduction, edge enhancement and contrast enhancement. The objective of this project is to enhance the mammographic image by using Interactive Data Language (IDL) software in spatial and frequency domain by using various methods. In spatial domain method, direct manipulation of pixel in an image is used whereas, in frequency domain method, modifying the spectral component or Fourier Transform of an image is used In order to obtain the good quality mammographic image, breast phantom Model 12A with 4.0 cm compressed thickness and Bennett Model DMF- 150 Mammography Machine with various kV and mA are employed. The results of enhanced image with selected technique by using IDL are presented in this paper. (Author)

  10. Association between mammographic density and pregnancies relative to age and BMI: a breast cancer case-only analysis.

    Science.gov (United States)

    Hack, Carolin C; Emons, Julius; Jud, Sebastian M; Heusinger, Katharina; Adler, Werner; Gass, Paul; Haeberle, Lothar; Heindl, Felix; Hein, Alexander; Schulz-Wendtland, Rüdiger; Uder, Michael; Hartmann, Arndt; Beckmann, Matthias W; Fasching, Peter A; Pöhls, Uwe G

    2017-12-01

    Percentage mammographic density (PMD) is a major risk factor for breast cancer (BC). It is strongly associated with body mass index (BMI) and age, which are themselves risk factors for breast cancer. This analysis investigated the association between the number of full-term pregnancies and PMD in different subgroups relative to age and BMI. Patients were identified in the breast cancer database of the University Breast Center for Franconia. A total of 2410 patients were identified, for whom information on parity, age, and BMI, and a mammogram from the time of first diagnosis were available for assessing PMD. Linear regression analyses were conducted to investigate the influence on PMD of the number of full-term pregnancies (FTPs), age, BMI, and interaction terms between them. As in previous studies, age, number of FTPs, and BMI were found to be associated with PMD in the expected direction. However, including the respective interaction terms improved the prediction of PMD even further. Specifically, the association between PMD and the number of FTPs differed in young patients under the age of 45 (mean decrease of 0.37 PMD units per pregnancy) from the association in older age groups (mean decrease between 2.29 and 2.39 PMD units). BMI did not alter the association between PMD and the number of FTPs. The effect of pregnancies on mammographic density does not appear to become apparent before the age of menopause. The mechanism that drives the effect of pregnancies on mammographic density appears to be counter-regulated by other influences on mammographic density in younger patients.

  11. Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect.

    Science.gov (United States)

    Napolitano, Mary E; Trueblood, Jon H; Hertel, Nolan E; David, George

    2002-09-01

    A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within +/-1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine

  12. Mammographic x-ray unit kilovoltage test tool based on k-edge absorption effect

    International Nuclear Information System (INIS)

    Napolitano, Mary E.; Trueblood, Jon H.; Hertel, Nolan E.; David, George

    2002-01-01

    A simple tool to determine the peak kilovoltage (kVp) of a mammographic x-ray unit has been designed. Tool design is based on comparing the effect of k-edge discontinuity of the attenuation coefficient for a series of element filters. Compatibility with the mammography accreditation phantom (MAP) to obtain a single quality control film is a second design objective. When the attenuation of a series of sequential elements is studied simultaneously, differences in the absorption characteristics due to the k-edge discontinuities are more evident. Specifically, when the incident photon energy is higher than the k-edge energy of a number of the elements and lower than the remainder, an inflection may be seen in the resulting attenuation data. The maximum energy of the incident photon spectra may be determined based on this inflection point for a series of element filters. Monte Carlo photon transport analysis was used to estimate the photon transmission probabilities for each of the sequential k-edge filter elements. The photon transmission corresponds directly to optical density recorded on mammographic x-ray film. To observe the inflection, the element filters chosen must have k-edge energies that span a range greater than the expected range of the end point energies to be determined. For the design, incident x-ray spectra ranging from 25 to 40 kVp were assumed to be from a molybdenum target. Over this range, the k-edge energy changes by approximately 1.5 keV between sequential elements. For this design 21 elements spanning an energy range from 20 to 50 keV were chosen. Optimum filter element thicknesses were calculated to maximize attenuation differences at the k-edge while maintaining optical densities between 0.10 and 3.00. Calculated relative transmission data show that the kVp could be determined to within ±1 kV. To obtain experimental data, a phantom was constructed containing 21 different elements placed in an acrylic holder. MAP images were used to determine

  13. Study of quality perception in medical images based on comparison of contrast enhancement techniques in mammographic images

    Science.gov (United States)

    Matheus, B.; Verçosa, L. B.; Barufaldi, B.; Schiabel, H.

    2014-03-01

    With the absolute prevalence of digital images in mammography several new tools became available for radiologist; such as CAD schemes, digital zoom and contrast alteration. This work focuses in contrast variation and how the radiologist reacts to these changes when asked to evaluated image quality. Three contrast enhancing techniques were used in this study: conventional equalization, CCB Correction [1] - a digitization correction - and value subtraction. A set of 100 images was used in tests from some available online mammographic databases. The tests consisted of the presentation of all four versions of an image (original plus the three contrast enhanced images) to the specialist, requested to rank each one from the best up to worst quality for diagnosis. Analysis of results has demonstrated that CCB Correction [1] produced better images in almost all cases. Equalization, which mathematically produces a better contrast, was considered the worst for mammography image quality enhancement in the majority of cases (69.7%). The value subtraction procedure produced images considered better than the original in 84% of cases. Tests indicate that, for the radiologist's perception, it seems more important to guaranty full visualization of nuances than a high contrast image. Another result observed is that the "ideal" scanner curve does not yield the best result for a mammographic image. The important contrast range is the middle of the histogram, where nodules and masses need to be seen and clearly distinguished.

  14. A prototype for a mammographic head and related developments

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L

    2004-02-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni.

  15. A prototype for a mammographic head and related developments

    International Nuclear Information System (INIS)

    Amendolia, S.R.; Annovazzi, A.; Bigongiari, A.; Bisogni, M.G.; Catarsi, F.; Cesqui, F.; Cetronio, A.; Chianella, M.; Delogu, P.; Fantacci, M.E.; Galimberti, D.; Lanzieri, C.; Lavanga, S.; Novelli, M.; Passuello, G.; Stefanini, A.; Testa, A.; Venturelli, L.

    2004-01-01

    The Integrated Mammographic Imaging (IMI) project aims to realize innovative instrumentations for morphological and functional mammography, in particular, one of the research topics is the design and development of a prototype of a mammographic head. Innovative industrial processes for the production of GaAs pixel detectors and for their bump-bonding to the read-out VLSI electronics have been developed by AMS. The data acquisition and processing have been developed by LABEN; the power supply and distribution system has been realized by CAEN; while the integration of the head in a standard mammograph has been carried on by the Laboratori di Ricerca Gilardoni

  16. Mammographic Imaging Studies Using the Monte Carlo Image Simulation-Differential Sampling (MCMIS-DS) Code

    International Nuclear Information System (INIS)

    Kuruvilla Verghese

    2002-01-01

    This report summarizes the highlights of the research performed under the 1-year NEER grant from the Department of Energy. The primary goal of this study was to investigate the effects of certain design changes in the Fisher Senoscan mammography system and in the degree of breast compression on the discernability of microcalcifications in calcification clusters often observed in mammograms with tumor lesions. The most important design change that one can contemplate in a digital mammography system to improve resolution of calcifications is the reduction of pixel dimensions of the digital detector. Breast compression is painful to the patient and is though to be a deterrent to women to get routine mammographic screening. Calcification clusters often serve as markers (indicators ) of breast cancer

  17. Influence of lifestyle factors on mammographic density in postmenopausal women.

    Directory of Open Access Journals (Sweden)

    Judith S Brand

    Full Text Available BACKGROUND: Mammographic density is a strong risk factor for breast cancer. Apart from hormone replacement therapy (HRT, little is known about lifestyle factors that influence breast density. METHODS: We examined the effect of smoking, alcohol and physical activity on mammographic density in a population-based sample of postmenopausal women without breast cancer. Lifestyle factors were assessed by a questionnaire and percentage and area measures of mammographic density were measured using computer-assisted software. General linear models were used to assess the association between lifestyle factors and mammographic density and effect modification by body mass index (BMI and HRT was studied. RESULTS: Overall, alcohol intake was positively associated with percent mammographic density (P trend  = 0.07. This association was modified by HRT use (P interaction  = 0.06: increasing alcohol intake was associated with increasing percent density in current HRT users (P trend  = 0.01 but not in non-current users (P trend  = 0.82. A similar interaction between alcohol and HRT was found for the absolute dense area, with a positive association being present in current HRT users only (P interaction  = 0.04. No differences in mammographic density were observed across categories of smoking and physical activity, neither overall nor in stratified analyses by BMI and HRT use. CONCLUSIONS: Increasing alcohol intake is associated with an increase in mammography density, whereas smoking and physical activity do not seem to influence density. The observed interaction between alcohol and HRT may pose an opportunity for HRT users to lower their mammographic density and breast cancer risk.

  18. Mammographic density and histopathologic characteristics of screen-detected tumors in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Moshina, Nataliia; Ursin, Giske; Hoff, Solveig Roth; Akslen, Lars A; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2015-01-01

    High mammographic density might mask breast tumors, resulting in delayed diagnosis or missed cancers. To investigate the association between mammographic density and histopathologic tumor characteristics (histologic type, size, grade, and lymph node status) among women screened in the Norwegian Breast Cancer Screening Program. Information about 1760 screen-detected ductal carcinoma in situ (DCIS) and 7366 invasive breast cancers diagnosed among women aged 50–69 years, 1996–2010, was analyzed. The screening mammograms were classified subjectively according to the amount of fibroglandular tissue into fatty, medium dense, and dense by breast radiologists. Chi-square test was used to compare the distribution of tumor characteristics by mammographic density. Odds ratio (OR) of tumor characteristics by density was estimated by means of logistic regression, adjusting for screening mode (screen-film and full-field digital mammography), and age. Mean and median tumor size of invasive breast cancers was 13.8 and 12 mm, respectively, for women with fatty breasts, and 16.2 and 14 mm for those with dense breasts. Lymph node positive tumors were identified among 20.6% of women with fatty breasts compared with 27.2% of those with dense breasts (P < 0.001). The proportion of DCIS was significantly lower for women with fatty (15.8%) compared with dense breasts (22.0%). Women with dense breasts had an increased risk of large (OR, 1.44; 95% CI, 1.18–1.73) and lymph node positive tumors (OR, 1.26; 95% CI, 1.05–1.51) compared with women with fatty and medium dense breasts. High mammographic density was positively associated with tumor size and lymph node positive tumors

  19. Comparison of image quality between mammography dedicated monitor and UHD 4K monitor, using standard mammographic phantom: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Young; Cha, Soon Joo; Hong, Sung Hwan; Kim, Su Young; Kim, Yong Hoon; Kim, You Sung; Kim, Jeong A [Dept. of Radiology, Inje Unveristy Ilsan Paik Hospital, Goyang (Korea, Republic of)

    2017-03-15

    Using standard mammographic phantom images, we compared the image quality obtained between a mammography dedicated 5 megapixel monitor (5M) and a UHD 4K (4K) monitor with digital imaging and communications in medicine display, to investigate the possibility of clinical application of 4K monitors. Three different exposures (autoexposure, overexposure and underexposure) images of mammographic phantom were obtained, and six radiologists independently evaluated the images in 5M and 4K without image modulation, by scoring of fibers, groups of specks and masses within the phantom image. The mean score of each object on both monitors was independently analyzed, using t-test and interobserver reliability by intraclass correlation coefficient (ICC) of SPSS. The overall mean scores of fiber, group of specks, and mass in 5M were 4.25, 3.92, and 3.28 respectively, and scores obtained in 4K monitor were 3.81, 3.58, and 3.14, respectively. No statistical difference was seen in scores of fiber and mass between the two monitors at all exposure conditions, but the score of group of specks in 4K was statistically lower in the overall (p = 0.0492) and in underexposure conditions (p = 0.012). The ICC for interobserver reliability was excellent (0.874). Our study suggests that since the mammographic phantom images are appropriate with no significant difference in image quality observed between the two monitors, the 4K monitor could be used for clinical studies. Since this is a small preliminary study using phantom images, the result may differ in actual mammographic images, and subsequent investigation with clinical mammographic images is required.

  20. Mammographic Findings after Intraoperative Radiotherapy of the Breast

    International Nuclear Information System (INIS)

    Rivera, R.; Holmes, D.R.; Smith-Bronstein, V.S.; Villegas-Mendez, S.; Rayhanabad, J.; Sheth, P.; Rashtian, A.

    2012-01-01

    Intraoperative Radiotherapy (IORT) is a form of accelerated partial breast radiation that has been shown to be equivalent to conventional whole breast external beam radiotherapy (EBRT) in terms of local cancer control. However, questions have been raised about the potential of f IORT to produce breast parenchymal changes that could interfere with mammographic surveillance of cancer recurrence. The purpose of this study was to identify, quantify, and compare the mammographic findings of patients who received IORT and EBRT in a prospective, randomized controlled clinical trial of women with early stage invasive breast cancer undergoing breast conserving therapy between July 2005 and December 2009. Treatment groups were compared with regard to the 1, 2 and 4-year incidence of 6 post-operative mammographic findings: architectural distortion, skin thickening, skin retraction, calcifications, fat necrosis, and mass density. Blinded review of 90 sets of mammograms of 15 IORT and 16 EBRT patients demonstrated a higher incidence of fat necrosis among IORT recipients at years 1, 2, and 4. However, none of the subjects were judged to have suspicious mammogram findings and fat necrosis did not interfere with mammographic interpretation.

  1. Digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Haegele, Julian; Barkhausen, Joerg; Pursche, Telja; Schaefer, Fritz K.W.

    2015-01-01

    In digital breast tomosynthesis a digital tomographic data set with a very high spatial resolution is reconstructed from low-dose projections collected over a limited rotation angle. This allows a very detailed assessment of e. g. masses and architectural distortions. The average glandular dose is comparable to 2 D mammography. First clinical studies demonstrated that tomosynthesis is able to supply important additional information in suspicious mammographic findings. In comparison to projection mammography, tomosynthesis shows an at least comparable diagnostic accuracy. In everyday practice, tomosynthesis is currently mostly used for further evaluation of suspicious findings in mammography.

  2. Digital mammography screening: average glandular dose and first performance parameters

    International Nuclear Information System (INIS)

    Weigel, S.; Girnus, R.; Czwoydzinski, J.; Heindel, W.; Decker, T.; Spital, S.

    2007-01-01

    Purpose: The Radiation Protection Commission demanded structured implementation of digital mammography screening in Germany. The main requirements were the installation of digital reference centers and separate evaluation of the fully digitized screening units. Digital mammography screening must meet the quality standards of the European guidelines and must be compared to analog screening results. We analyzed early surrogate indicators of effective screening and dosage levels for the first German digital screening unit in a routine setting after the first half of the initial screening round. Materials and Methods: We used three digital mammography screening units (one full-field digital scanner [DR] and two computed radiography systems [CR]). Each system has been proven to fulfill the requirements of the National and European guidelines. The radiation exposure levels, the medical workflow and the histological results were documented in a central electronic screening record. Results: In the first year 11,413 women were screened (participation rate 57.5 %). The parenchymal dosages for the three mammographic X-ray systems, averaged for the different breast sizes, were 0.7 (DR), 1.3 (CR), 1.5 (CR) mGy. 7 % of the screened women needed to undergo further examinations. The total number of screen-detected cancers was 129 (detection rate 1.1 %). 21 % of the carcinomas were classified as ductal carcinomas in situ, 40 % of the invasive carcinomas had a histological size ≤ 10 mm and 61 % < 15 mm. The frequency distribution of pT-categories of screen-detected cancer was as follows: pTis 20.9 %, pT1 61.2 %, pT2 14.7 %, pT3 2.3 %, pT4 0.8 %. 73 % of the invasive carcinomas were node-negative. (orig.)

  3. Indications and guidelines for mammographic examinations

    International Nuclear Information System (INIS)

    Kalisher, L.; Schaffer, D.

    1977-01-01

    The value of mammography in evaluating the asymptomatic patient has been clearly demonstrated by the HIP program, as well as the National Cancer Institute's breast demonstration projects. A one-third reduction in mortality from breast cancer in mammographically screened women has been substantiated. Nonetheless, questions concerning the long-term effects of repeated radiation exposure associated with mammography have been raised, and for this reason judicious selection of women is urged. In general, women who are asymptomatic or at high risk for breast carcinoma should be evaluated with a planned regimen. Mammographic guidelines and recommendations for attaining the greatest benefit at the lowest possible risk are suggested

  4. Use of border information in the classification of mammographic masses

    International Nuclear Information System (INIS)

    Varela, C; Timp, S; Karssemeijer, N

    2006-01-01

    We are developing a new method to characterize the margin of a mammographic mass lesion to improve the classification of benign and malignant masses. Towards this goal, we designed features that measure the degree of sharpness and microlobulation of mass margins. We calculated these features in a border region of the mass defined as a thin band along the mass contour. The importance of these features in the classification of benign and malignant masses was studied in relation to existing features used for mammographic mass detection. Features were divided into three groups, each representing a different mass segment: the interior region of a mass, the border and the outer area. The interior and the outer area of a mass were characterized using contrast and spiculation measures. Classification was done in two steps. First, features representing each of the three mass segments were merged into a neural network classifier resulting in a single regional classification score for each segment. Secondly, a classifier combined the three single scores into a final output to discriminate between benign and malignant lesions. We compared the classification performance of each regional classifier and the combined classifier on a data set of 1076 biopsy proved masses (590 malignant and 486 benign) from 481 women included in the Digital Database for Screening Mammography. Receiver operating characteristic (ROC) analysis was used to evaluate the accuracy of the classifiers. The area under the ROC curve (A z ) was 0.69 for the interior mass segment, 0.76 for the border segment and 0.75 for the outer mass segment. The performance of the combined classifier was 0.81 for image-based and 0.83 for case-based evaluation. These results show that the combination of information from different mass segments is an effective approach for computer-aided characterization of mammographic masses. An advantage of this approach is that it allows the assessment of the contribution of regions rather

  5. Comparative study of radiation dose between digital panoramic X-ray unit and general panoramic X-ray unit

    International Nuclear Information System (INIS)

    Li Qingshan; Duan Tao; Wang Xiaoyun; Zhao Li; Dong Jian; Wei Lei

    2010-01-01

    Objective: To compare the actual dose of patients who receive the same medical practice by either digital panoramic X-ray unit and general panoramic X-ray unit and give evidence for better selection of oral X-ray examination method. Methods: Round sheet lithium fluoride (LiF) thermoluminescent dosimeters (TLD) were used. The experiment was divided into natural background contrast group, general panoramic X-ray children group, general panoramic X-ray adults group, digital panoramic X-ray children group and digital panoramic X-ray adults group. The dosimeter of natural background radiation was placed at the office of the doctor, the dosimeters of general panoramic X-ray children group and general panoramic X-ray adults group were irradiated by different conditions according to the clinical application of panoramic X-ray to children and adults, the dosimeters of digital panoramic X-ray children group and digital panoramic X-ray adults group were irradiated by different conditions according to the clinical application of digital panoramic X-ray to children and adults. The thermoluminescent dosimeter was used to count and calculate the exposure doses in various groups. Results: The dose of children exposed in general panoramic X-ray unit was 1.28 times of that in digital panoramic X-ray unit, there was significant difference (t=6.904, P<0.01). The dose of adults exposed in general panoramic X-ray unit was 1.55 times of that in the digital panoramic X-ray unit, there also was significant difference (t=-11.514. P< 0.01). Conclusion: The digital panoramic X-ray unit can reduce the dose of patients, so the digital panoramic X-ray unit should be used as far as possible. (authors)

  6. Comparison of Danish dichotomous and BI-RADS classifications of mammographic density

    DEFF Research Database (Denmark)

    Hodge, Rebecca; Hellmann, Sophie Sell; von Euler-Chelpin, My

    2014-01-01

    BACKGROUND: In the Copenhagen mammography screening program from 1991 to 2001, mammographic density was classified either as fatty or mixed/dense. This dichotomous mammographic density classification system is unique internationally, and has not been validated before. PURPOSE: To compare the Danish...... dichotomous mammographic density classification system from 1991 to 2001 with the density BI-RADS classifications, in an attempt to validate the Danish classification system. MATERIAL AND METHODS: The study sample consisted of 120 mammograms taken in Copenhagen in 1991-2001, which tested false positive......, and which were in 2012 re-assessed and classified according to the BI-RADS classification system. We calculated inter-rater agreement between the Danish dichotomous mammographic classification as fatty or mixed/dense and the four-level BI-RADS classification by the linear weighted Kappa statistic. RESULTS...

  7. Proton Testing of Advanced Stellar Compass Digital Processing Unit

    DEFF Research Database (Denmark)

    Thuesen, Gøsta; Denver, Troelz; Jørgensen, Finn E

    1999-01-01

    The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland.......The Advanced Stellar Compass Digital Processing Unit was radiation tested with 300 MeV protons at Proton Irradiation Facility (PIF), Paul Scherrer Institute, Switzerland....

  8. Ultrasonographic Findings of Mammographic Architectural Distortion

    International Nuclear Information System (INIS)

    Ma, Jeong Hyun; Kang, Bong Joo; Cha, Eun Suk; Hwangbo, Seol; Kim, Hyeon Sook; Park, Chang Suk; Kim, Sung Hun; Choi, Jae Jeong; Chung, Yong An

    2008-01-01

    To review the sonographic findings of various diseases showing architectural distortion depicted under mammography. We collected and reviewed architectural distortions observed under mammography at our health institution between 1 March 2004, and 28 February 2007. We collected 23 cases of sonographically-detected mammographic architectural distortions that confirmed lesions after surgical resection. The sonographic findings of mammographic architectural distortion were analyzed by use of the BI-RADS lexicon for shape, margin, lesion boundary, echo pattern, posterior acoustic feature and orientation. There were variable diseases that showed architectural distortion depicted under mammography. Fibrocystic disease was the most common presentation (n = 6), followed by adenosis (n = 2), stromal fibrosis (n = 2), radial scar (n = 3), usual ductal hyperplasia (n = 1), atypical ductal hyperplasia (n = 1) and mild fibrosis with microcalcification (n = 1). Malignant lesions such as ductal carcinoma in situ (DCIS) (n = 2), lobular carcinoma in situ (LCIS) (n = 2), invasive ductal carcinoma (n = 2) and invasive lobular carcinoma (n = 1) were observed. As observed by sonography, shape was divided as irregular (n = 22) and round (n = 1). Margin was divided as circumscribed (n = 1), indistinct (n = 7), angular (n = 1), microlobulated (n = 1) and sipculated (n = 13). Lesion boundary was divided as abrupt interface (n = 11) and echogenic halo (n = 12). Echo pattern was divided as hypoechoic (n = 20), anechoic (n = 1), hyperechoic (n = 1) and isoechoic (n = 1). Posterior acoustic feature was divided as posterior acoustic feature (n = 7), posterior acoustic shadow (n = 15) and complex posterior acoustic feature (n = 1). Orientation was divided as parallel (n = 12) and not parallel (n = 11). There were no differential sonographic findings between benign and malignant lesions. This study presented various sonographic findings of mammographic architectural distortion and that it is

  9. Evaluation of the image quality in digital breast tomosynthesis (DBT) employed with a compressed-sensing (CS)-based reconstruction algorithm by using the mammographic accreditation phantom

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeonok; Cho, Heemoon; Je, Uikyu; Cho, Hyosung, E-mail: hscho1@yonsei.ac.kr; Park, Chulkyu; Lim, Hyunwoo; Kim, Kyuseok; Kim, Guna; Park, Soyoung; Woo, Taeho; Choi, Sungil

    2015-12-21

    In this work, we have developed a prototype digital breast tomosynthesis (DBT) system which mainly consists of an x-ray generator (28 kV{sub p}, 7 mA s), a CMOS-type flat-panel detector (70-μm pixel size, 230.5×339 mm{sup 2} active area), and a rotational arm to move the x-ray generator in an arc. We employed a compressed-sensing (CS)-based reconstruction algorithm, rather than a common filtered-backprojection (FBP) one, for more accurate DBT reconstruction. Here the CS is a state-of-the-art mathematical theory for solving the inverse problems, which exploits the sparsity of the image with substantially high accuracy. We evaluated the reconstruction quality in terms of the detectability, the contrast-to-noise ratio (CNR), and the slice-sensitive profile (SSP) by using the mammographic accreditation phantom (Model 015, CIRS Inc.) and compared it to the FBP-based quality. The CS-based algorithm yielded much better image quality, preserving superior image homogeneity, edge sharpening, and cross-plane resolution, compared to the FBP-based one. - Highlights: • A prototype digital breast tomosynthesis (DBT) system is developed. • Compressed-sensing (CS) based reconstruction framework is employed. • We reconstructed high-quality DBT images by using the proposed reconstruction framework.

  10. Area and volumetric density estimation in processed full-field digital mammograms for risk assessment of breast cancer.

    Directory of Open Access Journals (Sweden)

    Abbas Cheddad

    Full Text Available INTRODUCTION: Mammographic density, the white radiolucent part of a mammogram, is a marker of breast cancer risk and mammographic sensitivity. There are several means of measuring mammographic density, among which are area-based and volumetric-based approaches. Current volumetric methods use only unprocessed, raw mammograms, which is a problematic restriction since such raw mammograms are normally not stored. We describe fully automated methods for measuring both area and volumetric mammographic density from processed images. METHODS: The data set used in this study comprises raw and processed images of the same view from 1462 women. We developed two algorithms for processed images, an automated area-based approach (CASAM-Area and a volumetric-based approach (CASAM-Vol. The latter method was based on training a random forest prediction model with image statistical features as predictors, against a volumetric measure, Volpara, for corresponding raw images. We contrast the three methods, CASAM-Area, CASAM-Vol and Volpara directly and in terms of association with breast cancer risk and a known genetic variant for mammographic density and breast cancer, rs10995190 in the gene ZNF365. Associations with breast cancer risk were evaluated using images from 47 breast cancer cases and 1011 control subjects. The genetic association analysis was based on 1011 control subjects. RESULTS: All three measures of mammographic density were associated with breast cancer risk and rs10995190 (p0.10 for risk, p>0.03 for rs10995190. CONCLUSIONS: Our results show that it is possible to obtain reliable automated measures of volumetric and area mammographic density from processed digital images. Area and volumetric measures of density on processed digital images performed similar in terms of risk and genetic association.

  11. Mammographic screening practices among Chinese-Australian women.

    Science.gov (United States)

    Kwok, Cannas; Fethney, Judith; White, Kate

    2012-03-01

    To report mammographic screening practice among Chinese-Australian women, and to examine the relationship between demographic characteristics, acculturation factors (English proficiency and length of stay in Australia), cultural beliefs, and having a mammogram as recommended. Cross-sectional and descriptive. The study was conducted in 2009 in Sydney, Australia. Of 988 Chinese-Australian women over 18 years of age invited to participate in the study, 785 (79%) completed and returned the questionnaire. Of these women, 320 (40.8%) were in the target age range of 50 to 69 years. The Chinese Breast Cancer Screening Beliefs Questionnaire (CBCSB) was used as a data collection instrument. Analysis included descriptive statistics, bivariate analysis using chi-square and t tests, and logistic regression. Of the 320 women in the targeted age range of 50 to 69 years, 238 (74.4%) had a mammogram as recommended biannually. Being married-de facto, in the 60 to 69 age group, and speaking Cantonese at home were positively associated with women's mammographic screening practice. However, no statistically significant differences in acculturation factors and having a mammogram as recommended were found. In terms of CBCSB score, women who had mammograms as recommended had more positive attitudes toward health checkups and perceived fewer barriers to mammographic screening. Effort should be focused on specific subgroups of Chinese-Australian women in order to fully understand the barriers involved in participating in mammographic screening. Nurses can use the findings from the present study to design culturally sensitive breast cancer screening programs to encourage women's participation in mammography. © 2011 Sigma Theta Tau International.

  12. THE MAMMOGRAPHIC CALCIFICATIONS IN BREAST CANCER

    Institute of Scientific and Technical Information of China (English)

    Tang Ruiying; Liu Jingxian; Gaowen

    1998-01-01

    Objective: This study was performed to exam the relativeship between mammographic calcifications and breast cancer. Methods: All of the 184 patients with breast diseases underwent mammography before either an open biopsy or a mastectomy. The presence,morphology, and distribution of calcifications visualized on mammograms for breast cancer were compared with the controls who remained cancer free. Statistical comparisons were made by using the x2 test. Results:Of the 184 patients with breast diaeases, 93 malignant and 91 benign lesions were histologically confirmed.Calcifications were visualized on mammograms in 60(64%) of 93 breast cancers and 26 (28%) of 91 non breast cancers. The estimated odds ratio (OR) of breast cancer was 4.5 in women with calcifications seen on mammograms, compared with those having none (P<0.01). Of the 60 breast carcinomas having mammographic calcifications, 28 (47%) were infiltrating ductal carcinomas.There were only 8 (24%) cases with infiltrating ductal cancers in the group of without calcifications seen on the mammograms (P<0.05). Conclusion: Our finding suggests that mammographic calcification appears to be a risk factor for breast cancer. The granular and linear cast type calcification provide clues to the presence of breast cancer, especially when the carcinomas without associated masses were seen on mammograms.

  13. Mammographic breast density patterns among a group of women in ...

    African Journals Online (AJOL)

    Introduction: Mammographic breast density is a measure of parenchymal breast patterns on film and in part a marker of cumulative exposure to oestrogen. The risk of breast cancer for women with increased density is up to six fold more than in women with less dense tissues. The pattern of mammographic breast density ...

  14. Effective dose from direct and indirect digital panoramic units

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gun Sun; Kim, Jin Soo; Seo, Yo Seob; Kim, Jae Duk [School of Dentistry, Oral Biology Research Institute, Chosun University, Gwangju (Korea, Republic of)

    2013-06-15

    This study aimed to provide comparative measurements of the effective dose from direct and indirect digital panoramic units according to phantoms and exposure parameters. Dose measurements were carried out using a head phantom representing an average man (175 cm tall, 73.5 kg male) and a limbless whole body phantom representing an average woman (155 cm tall, 50 kg female). Lithium fluoride thermoluminescent dosimeter (TLD) chips were used for the dosimeter. Two direct and 2 indirect digital panoramic units were evaluated in this study. Effective doses were derived using 2007 International Commission on Radiological Protection (ICRP) recommendations. The effective doses of the 4 digital panoramic units ranged between 8.9 {mu}Sv and 37.8 {mu}Sv. By using the head phantom, the effective doses from the direct digital panoramic units (37.8 {mu}Sv, 27.6 {mu}Sv) were higher than those from the indirect units (8.9 {mu}Sv, 15.9 {mu}Sv). The same panoramic unit showed the difference in effective doses according to the gender of the phantom, numbers and locations of TLDs, and kVp. To reasonably assess the radiation risk from various dental radiographic units, the effective doses should be obtained with the same numbers and locations of TLDs, and with standard hospital exposure. After that, it is necessary to survey the effective doses from various dental radiographic units according to the gender with the corresponding phantom.

  15. Portable Power And Digital-Communication Units

    Science.gov (United States)

    Levin, Richard R.; Henry, Paul K.; Rosenberg, Leigh S.

    1992-01-01

    Conceptual network of electronic-equipment modules provides electrical power and digital radio communications at multiple sites not served by cables. System includes central communication unit and portable units powered by solar photovoltaic arrays. Useful to serve equipment that must be set up quickly at remote sites or buildings that cannot be modified to provide cable connections.

  16. Mucinous carcinoma of the breast: mammographic features with histologic correlation

    International Nuclear Information System (INIS)

    Cui Chunyan; Zhang Ling; Wu Yaopan; Li Shuqin

    2011-01-01

    Objective: To correlate the mammographic findings of mucinous carcinoma with histologic features. Methods: Retrospective analysis of the mammographic and pathologic findings of 37 patients with mucinous carcinomas of the breasts was performed. Results: Mammograms of ten (52.6%) women with mucinous carcinomas showed masses with well-defined, lobu-lated margins correlating well with the pure histologic type. Thirteen (81.3%) mixed type of mucinous carcinomas demonstrated poorly defined or spiculated margins (P<0.05). Most of the pure type carcinomas were hyperdense similar to most of mixed type carcinomas (P<0.05). Of 34 mucinous carcinomas tested, there were 25 ER-positive, 29 PR-positive, 24 C-erbB-2 negative expressions with pure type carcinomas accounting for 78.9%, 89.5% and 78.9%, respectively. Conclusion: The mammographic features of pure type are different from those of mixed type of mucinous breast carcinomas. The most common mammographic appearance of pure mucinous carcinoma is a well-defined mass without calcification whereas the mixed type carcinomas have more aggressive imaging characteristics. (authors)

  17. Collaborating with Mammographers to Address Their Work-Related Musculoskeletal Discomfort

    Science.gov (United States)

    Sommerich, Carolyn M.; Lavender, Steven A.; Evans, Kevin D.; Sanders, Elizabeth; Joines, Sharon; Lamar, Sabrina; Umar, Radin Zaid Radin; Yen, Wei-Ting; Park, SangHyun

    2017-01-01

    Mammographers are an understudied group of healthcare workers, yet the prevalence of musculoskeletal (MSK) symptoms in mammographers appears to be elevated, similar to many occupations in healthcare. In this study, we used a participatory approach to identify needs and opportunities for developing interventions to reduce mammographers’ exposures to risk factors that lead to development of MSK symptoms. In this paper, we present a number of those needs and several intervention concepts along with evaluations of those concepts from experienced mammographers. We include findings from a preliminary field test of a novel intervention concept to reduce the need to adopt awkward postures while positioning patients for a screening or diagnostic mammogram. PMID:26794257

  18. Breast cancer detection using sonography in women with mammographically dense breasts

    International Nuclear Information System (INIS)

    Okello, Jimmy; Kisembo, Harriet; Bugeza, Sam; Galukande, Moses

    2014-01-01

    Mammography, the gold standard for breast cancer screening misses some cancers, especially in women with dense breasts. Breast ultrasonography as a supplementary imaging tool for further evaluation of symptomatic women with mammographically dense breasts may improve the detection of mass lesions otherwise missed at mammography. The purpose of this study was to determine the incremental breast cancer detection rate using US scanning in symptomatic women with mammographically dense breasts in a resource poor environment. A cross sectional descriptive study. Women referred for mammography underwent bilateral breast ultrasound, and mammography for symptom evaluation. The lesions seen by both modalities were described using sonographic BI-RADS lexicon and categorized. Ultrasound guided core biopsies were performed. IRB approval was obtained and all participants provided informed written consent. In total 148 women with mammographically dense breasts were recruited over six months. The prevalence of breast cancer in symptomatic women with mammographically dense breasts was 22/148 (15%). Mammography detected 16/22 (73%) of these cases and missed 6/22 (27%). The six breast cancer cases missed were correctly diagnosed on breast ultrasonography. Sonographic features typical of breast malignancy were irregular shape, non-parallel orientation, non circumscribed margin, echogenic halo, and increased lesion vascularity (p values < 0.005). Typical sonofeatures of benign mass lesions were: oval shape, parallel orientation and circumscribed margin (p values <0.005). Breast ultrasound scan as a supplementary imaging tool detected 27% more malignant mass lesions otherwise missed by mammography among these symptomatic women with mammographically dense breasts. We recommend that ultra sound scanning in routine evaluation of symptomatic women with mammographically dense breasts

  19. Fibroadenomas Frequency in uncertain mammographic lesions: Histology Correlation

    International Nuclear Information System (INIS)

    Hincapie Uribe, Ana Lucia; Patino Pacheco, Jairo H; Restrepo Mejia, Ana Lucia

    1997-01-01

    Purpose was to determine the frequency of fibroadenomas in non-palpable mammographic lesions, histologically evaluated and describe its radiological characteristics according to the type of mammographic presentation and classification. 60 (8.6%) fibroadenomas were found in 692 biopsies performed. 50% of these were mammographicaly classified as category 3 and 50% in the category 4. 66.6% of them were nodules, 20% isolated calcifications and nodules with calcifications 13.3%. fibroadenomas were 26.4% of nodules in category 3 and 18.8% of them in category 4

  20. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  1. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  2. Double-blind randomized 12-month soy intervention had no effects on breast MRI fibroglandular tissue density or mammographic density

    Science.gov (United States)

    Wu, Anna H.; Spicer, Darcy; Garcia, Agustin; Tseng, Chiu-Chen; Hovanessian-Larsen, Linda; Sheth, Pulin; Martin, Sue Ellen; Hawes, Debra; Russell, Christy; McDonald, Heather; Tripathy, Debu; Su, Min-Ying; Ursin, Giske; Pike, Malcolm C.

    2015-01-01

    Soy supplementation by breast cancer patients remains controversial. No controlled intervention studies have investigated the effects of soy supplementation on mammographic density in breast cancer patients. We conducted a double-blind, randomized, placebo-controlled intervention study in previously treated breast cancer patients (n=66) and high-risk women (n=29). We obtained digital mammograms and breast magnetic resonance imaging (MRI) scans at baseline and after 12 months of daily soy (50 mg isoflavones per day) (n=46) or placebo (n=49) tablet supplementation. The total breast area (MA) and the area of mammographic density (MD) on the mammogram was measured using a validated computer-assisted method, and mammographic density percent (MD% = 100 × MD/MA) was determined. A well-tested computer algorithm was used to quantitatively measure the total breast volume (TBV) and fibroglandular tissue volume (FGV) on the breast MRI, and the FGV percent (FGV% = 100 × FGV/TBV) was calculated. On the basis of plasma soy isoflavone levels, compliance was excellent. Small decreases in MD% measured by the ratios of month 12 to baseline levels, were seen in the soy (0.95) and the placebo (0.87) groups; these changes did not differ between the treatments (P=0.38). Small decreases in FGV% were also found in both the soy (0.90) and the placebo (0.92) groups; these changes also did not differ between the treatments (P=0.48). Results were comparable in breast cancer patients and high-risk women. We found no evidence that soy supplementation would decrease mammographic density and that MRI might be more sensitive to changes in density than mammography. PMID:26276750

  3. The impact of mammographic screening on breast cancer mortality in Europe

    DEFF Research Database (Denmark)

    Broeders, Mireille; Moss, Sue; Nyström, Lennarth

    2012-01-01

    To assess the impact of population-based mammographic screening on breast cancer mortality in Europe, considering different methodologies and limitations of the data.......To assess the impact of population-based mammographic screening on breast cancer mortality in Europe, considering different methodologies and limitations of the data....

  4. Comparison between the implementation of quality criteria of radiographic image in conventional and digital mammography equipments

    International Nuclear Information System (INIS)

    Alcantara, M.C.; Sordi, G.M.A.A.; Caldas, L.V.E.; Furquim, T.A.C.

    2008-01-01

    The mammographic examination needs a strict quality control. A publication of the European Commission provides guidelines on quality criteria for the images of the breast, quantifying the quality obtained in the image. Following the recommendations of the European Commission, two kinds of mammographic equipments, at a same institution, were evaluated to compare the quality of the conventional and digital images. Besides of that, the Average Glandular Dose (AGD) and the Entrance Surface Dose (ESD) were measured by using an ionization chamber (Radcal, 6M) in the radiation beams of each equipment. The digital equipment fulfills more quality criteria than the conventional equipment, provided ESD values, AGD values and a rejection index lower than the conventional equipment. Therefore, the digital mammography can be considered more adequate than the conventional one, both for criteria analyses and for dose optimization. (author)

  5. The digital ultrasonic test unit for automatic equipment

    International Nuclear Information System (INIS)

    Hiraoka, T.; Matsuyama, H.

    1976-01-01

    The operations and features of the ultrasonic test unit used and the digital data processing techniques employed are described. This unit is used for a few hundred multi-channel automatic ultrasonic test equipment

  6. Digital preservation initiatives in the United States: a summary

    OpenAIRE

    Marcum, Deanna

    2003-01-01

    General presentation on how digital preservation issues are being faced in the United States of America. Special reference to the National Digital Information Infrastructure and Preservation Program, that is found at the Library of Congress, and aims to implement a national strategy for the long-term preservation of digital content.

  7. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  8. MAS2-8 radar and digital control unit

    Science.gov (United States)

    Oberg, J. M.; Ulaby, F. T.

    1974-01-01

    The design of the MAS 2-8 (2 to 8 GHz microwave-active spectrometer), a ground-based sensor system, is presented. A major modification in 1974 to the MAS 2-8, that of a control subsystem to automate the data-taking operation, is the prime focus. The digital control unit automatically changes all system parameters except FM rate and records the return signal on paper tape. The overall system operation and a detailed discussion of the design and operation of the digital control unit are presented.

  9. Characterization of mammographic masses based on level set segmentation with new image features and patient information

    International Nuclear Information System (INIS)

    Shi Jiazheng; Sahiner, Berkman; Chan Heangping; Ge Jun; Hadjiiski, Lubomir; Helvie, Mark A.; Nees, Alexis; Wu Yita; Wei Jun; Zhou Chuan; Zhang Yiheng; Cui Jing

    2008-01-01

    Computer-aided diagnosis (CAD) for characterization of mammographic masses as malignant or benign has the potential to assist radiologists in reducing the biopsy rate without increasing false negatives. The purpose of this study was to develop an automated method for mammographic mass segmentation and explore new image based features in combination with patient information in order to improve the performance of mass characterization. The authors' previous CAD system, which used the active contour segmentation, and morphological, textural, and spiculation features, has achieved promising results in mass characterization. The new CAD system is based on the level set method and includes two new types of image features related to the presence of microcalcifications with the mass and abruptness of the mass margin, and patient age. A linear discriminant analysis (LDA) classifier with stepwise feature selection was used to merge the extracted features into a classification score. The classification accuracy was evaluated using the area under the receiver operating characteristic curve. The authors' primary data set consisted of 427 biopsy-proven masses (200 malignant and 227 benign) in 909 regions of interest (ROIs) (451 malignant and 458 benign) from multiple mammographic views. Leave-one-case-out resampling was used for training and testing. The new CAD system based on the level set segmentation and the new mammographic feature space achieved a view-based A z value of 0.83±0.01. The improvement compared to the previous CAD system was statistically significant (p=0.02). When patient age was included in the new CAD system, view-based and case-based A z values were 0.85±0.01 and 0.87±0.02, respectively. The study also demonstrated the consistency of the newly developed CAD system by evaluating the statistics of the weights of the LDA classifiers in leave-one-case-out classification. Finally, an independent test on the publicly available digital database for screening

  10. COMBINED MAMMOGRAPHIC AND SONOGRAPHIC EVALUATION OF PALPABLE BREAST MASSES

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-10-01

    Full Text Available BACKGROUND Breast diseases are common in females. In developing countries like India, females are unaware of breast pathologies hence they are detected usually in advanced stages. We have studied 100 patients of palpable breast masses presenting to our department and evaluate the role of combined mammographic and sonographic imaging in patients with palpable abnormalities of the breast, which help in decision making by clinician as to lesion go for biopsy or follow up. MATERIALS AND METHODS The study was conducted at Department of Radiodiagnosis J. L.N. Medical College & Associated Groups of Hospitals, Ajmer. We included women equal to or more than 30 years referred to this centre with palpable abnormalities of breast during a period from March 2015 to August 2016. All these women underwent a combined mammographic and sonographic evaluation of breast. RESULTS 50 (50% of the 100 palpable abnormalities had benign assessment, 30 (60% of the benign lesions were visible both on mammography and sonography; 18 (36% of the 50 benign lesions were mammographically occult and identified at sonographic evaluation. 2 lesion was sonographically occult (4% and visualized on mammography. In 14 (14% of the 100 cases, imaging evaluation resulted in a suspicious assessment and all these lesions underwent biopsy and 4 were diagnosed as having malignancy. 36(36% of the 100 palpable abnormalities had negative imaging assessment finding: of these 14 patients underwent biopsy and all had benign findings. The sensitivity and negative predictive value for combined mammographic and sonographic assessment were 100%; the specificity was 78.26%. CONCLUSION Combined use of mammography and sonography plays an important role in the management of palpable breast lesions. It characterizes the palpable mass lesion, avoids unnecessary interventions in which imaging findings are unequivocally benign. Negative findings on combined mammographic and sonographic imaging have very high

  11. Computer-aided diagnosis of mammographic microcalcification clusters

    International Nuclear Information System (INIS)

    Kallergi, Maria

    2004-01-01

    Computer-aided diagnosis techniques in medical imaging are developed for the automated differentiation between benign and malignant lesions and go beyond computer-aided detection by providing cancer likelihood for a detected lesion given image and/or patient characteristics. The goal of this study was the development and evaluation of a computer-aided detection and diagnosis algorithm for mammographic calcification clusters. The emphasis was on the diagnostic component, although the algorithm included automated detection, segmentation, and classification steps based on wavelet filters and artificial neural networks. Classification features were selected primarily from descriptors of the morphology of the individual calcifications and the distribution of the cluster. Thirteen such descriptors were selected and, combined with patient's age, were given as inputs to the network. The features were ranked and evaluated for the classification of 100 high-resolution, digitized mammograms containing biopsy-proven, benign and malignant calcification clusters. The classification performance of the algorithm reached a 100% sensitivity for a specificity of 85% (receiver operating characteristic area index A z =0.98±0.01). Tests of the algorithm under various conditions showed that the selected features were robust morphological and distributional descriptors, relatively insensitive to segmentation and detection errors such as false positive signals. The algorithm could exceed the performance of a similar visual analysis system that was used as basis for development and, combined with a simple image standardization process, could be applied to images from different imaging systems and film digitizers with similar sensitivity and specificity rates

  12. Digital Mammography Tomosynthesis

    International Nuclear Information System (INIS)

    Gergov, I.; Alexov, G.; Rusonov, K.

    2017-01-01

    Siemens MAMMOMAT Inspiration with Tomosynthesis enhances the diagnostic precision in mammographic screening. The apparatus has a wide-angle tomosynthesis up to 50 degrees. The Siemens breast augmentation algorithm reconstructs multiple two-dimensional breast images into three-dimensional images at the lowest doses to help detect tumors hidden from the overlapping chest tissue, allowing for a more accurate diagnosis than standard 2-dimensional digital mammography, and reducing the number of false positive results. 3D digital tomosynthesis improves the precision of detecting and diagnosing a larger number of expansive lesions, ensures better morphological mass analysis and architectural distortion, and detecting calcifications by adding digital breast tomosynthesis to the traditional two-dimensional digital mammogram of the patient. In this way, it solves the problem of overlapping parenchyma, reduces the number of unnecessary biopsies from questionable sonomammographic findings, and the need for stressful repeating procedures, which usually contributes to both better patient outcomes and cost saving. [bg

  13. Analysis of mammographic findings of breast cancer

    International Nuclear Information System (INIS)

    Park, Hyun Joo; Han, Heon; Yang, Dal Mo; Chung, Hyo Sun; Kim, Jee Eun; Kim, Young Chae

    1995-01-01

    This study is to describe authors' experience on mammographic findings of breast cancer and to know if there is difference between 35 years of age or younger and older groups. Mammograms of 72 patients with breast cancer detected from January, 1991 to December, 1993 were retrospectively analysed. Mammographic findings were classified into mass only, mass with microcalcifications, microcalcifications only and others. Marginal characteristics of mass were classified into spiculated, poorly marginated and well marginated. Shape of microcalcifications were classified into casting, granular and mixed types. These findings were compared between 35 years of age or younger and older groups. Mammogram showed mass only in 33 patients (46%), mass with microcalcifications in 26 patients (36%), microcalcifications only in seven (10%) and other findings in six (8%). Other findings were architectural distortion, asymmetric high density and incidental breast carcinoma from paraffinoma in one patient respectively, and dense breast in three patients. The margins of the breast mass were spiculated in ten (17%). poorly marginated in 30 (51%), well-marginated in 19 (32%). Shape of microcalcifications were casting type in 13 (40%). granular in 14 (42%) and mixed in six (18%) cases. 3 patients had dense breast with which mammography did not demonstrate the lesion. 3 patients without mammographically demonstrable lesions due to dense breasts were under 35 years in age, and there was statistically significant difference between the two groups (ρ -value < 0.05). Microcalcifications only was more common findings in 35 years of age or younger. The most important mammographic findings of breast cancer were mass and microcalcifications. Architectural distortion and asymmetric high density were additional findings. In 35 years of age or younger, microcalcifications only was an important finding because mass lesions are frequently masked by dense breast. Thus other imaging modalities, such as

  14. Mammographic Breast Density in a Cohort of Medically Underserved Women

    Science.gov (United States)

    2015-12-01

    was a training year and during Years 2 through 4 a case-control study of obesity , insulin resistance and mammographic breast density was conducted. A...factors including health literacy, and to collect anthropometric measurements and fasting blood, 3) to assay blood for select hormones and growth...factors, 4) to perform statistical analyses to determine the associations between obesity and insulin resistance and mammographic breast density, and 5

  15. Digital breast tomosynthesis for breast cancer screening and diagnosis in women with dense breasts - a systematic review and meta-analysis

    NARCIS (Netherlands)

    Phi, Xuan-Anh; Tagliafico, Alberto; Houssami, Nehmat; Greuter, Marcel J. W.; de Bock, Geertruida H.

    2018-01-01

    Background: This study aimed to systematically review and to meta-analyse the accuracy of digital breast tomosynthesis (DBT) versus digital mammography (DM) in women with mammographically dense breasts in screening and diagnosis. Methods: Two independent reviewers identified screening or diagnostic

  16. Digital breast tomosynthesis for breast cancer screening and diagnosis in women with dense breasts - a systematic review and meta-analysis

    NARCIS (Netherlands)

    Phi, Xuan-Anh; Tagliafico, Alberto; Houssami, Nehmat; Greuter, Marcel J W; de Bock, Geertruida H

    2018-01-01

    BACKGROUND: This study aimed to systematically review and to meta-analyse the accuracy of digital breast tomosynthesis (DBT) versus digital mammography (DM) in women with mammographically dense breasts in screening and diagnosis. METHODS: Two independent reviewers identified screening or diagnostic

  17. Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

    International Nuclear Information System (INIS)

    Malkov, Serghei; Wang, Jeff; Kerlikowske, Karla; Cummings, Steven R.; Shepherd, John A.

    2009-01-01

    Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a ±2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

  18. Early detection of the incidence of malignancy in mammograms using digital image correlation

    International Nuclear Information System (INIS)

    Espitia, J.; Jacome, J.; Torres, C.

    2016-01-01

    The digital image correlation has proved an effective way for Pattern Recognition, this research to identify the using Findings digitally extracted from a mammographic image, which is the means used by more specialists to determine if a person is a candidate or not, a Suffer Breast Cancer. This shown that early detection of symptom logy 'carcinogenic' is the key . (Author)

  19. Digital Breast Tomosynthesis versus Supplemental Diagnostic Mammographic Views for Evaluation of Noncalcified Breast Lesions

    Science.gov (United States)

    Bandos, Andriy I.; Ganott, Marie A.; Sumkin, Jules H.; Kelly, Amy E.; Catullo, Victor J.; Rathfon, Grace Y.; Lu, Amy H.; Gur, David

    2013-01-01

    Purpose: To compare the diagnostic performance of breast tomosynthesis versus supplemental mammography views in classification of masses, distortions, and asymmetries. Materials and Methods: Eight radiologists who specialized in breast imaging retrospectively reviewed 217 consecutively accrued lesions by using protocols that were HIPAA compliant and institutional review board approved in 182 patients aged 31–60 years (mean, 50 years) who underwent diagnostic mammography and tomosynthesis. The lesions in the cohort included 33% (72 of 217) cancers and 67% (145 of 217) benign lesions. Eighty-four percent (182 of 217) of the lesions were masses, 11% (25 of 217) were asymmetries, and 5% (10 of 217) were distortions that were initially detected at clinical examination in 8% (17 of 217), at mammography in 80% (173 of 217), at ultrasonography (US) in 11% (25 of 217), or at magnetic resonance imaging in 1% (2 of 217). Histopathologic examination established truth in 191 lesions, US revealed a cyst in 12 lesions, and 14 lesions had a normal follow-up. Each lesion was interpreted once with tomosynthesis and once with supplemental mammographic views; both modes included the mediolateral oblique and craniocaudal views in a fully crossed and balanced design by using a five-category Breast Imaging Reporting and Data System (BI-RADS) assessment and a probability-of-malignancy score. Differences between modes were analyzed with a generalized linear mixed model for BI-RADS–based sensitivity and specificity and with modified Obuchowski-Rockette approach for probability-of-malignancy–based area under the receiver operating characteristic (ROC) curve. Results: Average probability-of-malignancy–based area under the ROC curve was 0.87 for tomosynthesis versus 0.83 for supplemental views (P tomosynthesis, the false-positive rate decreased from 85% (989 of 1160) to 74% (864 of 1160) (P tomosynthesis, more cancers were classified as BI-RADS category 5 (39% [226 of 576] vs 33% [188

  20. Diagnostic Performance of Mammographic Texture Analysis in the Differential Diagnosis of Benign and Malignant Breast Tumors.

    Science.gov (United States)

    Li, Zhiming; Yu, Lan; Wang, Xin; Yu, Haiyang; Gao, Yuanxiang; Ren, Yande; Wang, Gang; Zhou, Xiaoming

    2017-11-09

    The purpose of this study was to investigate the diagnostic performance of mammographic texture analysis in the differential diagnosis of benign and malignant breast tumors. Digital mammography images were obtained from the Picture Archiving and Communication System at our institute. Texture features of mammographic images were calculated. Mann-Whitney U test was used to identify differences between the benign and malignant group. The receiver operating characteristic (ROC) curve analysis was used to assess the diagnostic performance of texture features. Significant differences of texture features of histogram, gray-level co-occurrence matrix (GLCM) and run length matrix (RLM) were found between the benign and malignant breast group (P  .05). The AUROCs of imaging-based diagnosis, texture analysis, and imaging-based diagnosis combined with texture analysis were 0.873, 0.863, and 0.961, respectively. When imaging-based diagnosis was combined with texture analysis, the AUROC was higher than that of imaging-based diagnosis or texture analysis (P benign and malignant breast tumors. Furthermore, the combination of imaging-based diagnosis and texture analysis can significantly improve diagnostic performance. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    Science.gov (United States)

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (pChinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (pChinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  2. The mammographic correlations of a new immunohistochemical classification of invasive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Taneja, S. [Nottingham Breast Institute, City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom)], E-mail: sheeba_taneja@yahoo.co.uk; Evans, A.J. [Nottingham Breast Institute, City Hospital, Hucknall Road, Nottingham NG5 1PB (United Kingdom); Rakha, E.A.; Green, A.R. [Division of Pathology, School of Molecular Medical Sciences, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham (United Kingdom); Ball, G. [Nottingham Trent University, School of Biomedical and Natural Sciences, Nottingham (United Kingdom); Ellis, I.O. [Division of Pathology, School of Molecular Medical Sciences, Nottingham University Hospitals NHS Trust and University of Nottingham, Nottingham (United Kingdom)

    2008-11-15

    Aim: Recent protein expression profiling of breast cancer has identified specific subtypes with clinical, biological, and therapeutic implications. The aim of this study was to identify the mammographic correlates of these novel molecular classes of invasive breast cancer. Materials and methods: The mammographic findings of 415 patients with operable breast cancer were correlated with the previously described protein expression classes identified by our group using immunohistochemical (IHC) assessment of a large series of breast cancer cases prepared as tissue microarrays (TMAs). Twenty-five proteins of known relevance in breast cancer were assessed, including hormone receptors, HER-2 status, basal and luminal markers, p53 expression, and E-cadherin. Results: The mammographic background pattern and proportion of lesions that were mammographically occult were similar in all groups. Groups characterized by luminal and hormone receptor positivity had significantly more spiculate lesions at mammography. Groups characterized by HER-2 overexpression, basal characteristics, and E-cadherin positivity had a significantly higher proportion of ill-defined masses. These findings were independent of histological grade. Conclusion: The mammographic features of breast cancer show significant correlation with molecular classes of invasive breast cancer identified by protein expression IHC analysis. The biological reasons for the findings and implications of these regarding imaging protocols require further study and may provide mechanisms for improvement of detection of these lesions.

  3. Quantitative Assessment of Mammary Gland Density in Rodents Using Digital Image Analysis

    Directory of Open Access Journals (Sweden)

    Thompson Henry J

    2011-06-01

    Full Text Available Abstract Background Rodent models have been used extensively to study mammary gland development and for studies of toxicology and carcinogenesis. Mammary gland gross morphology can visualized via the excision of intact mammary gland chains following fixation and staining with carmine using a tissue preparation referred to as a whole mount. Methods are described for the automated collection of digital images from an entire mammary gland whole mount and for the interrogation of digital data using a "masking" technique available with Image-Pro® plus image analysis software (Mediacybernetics. Silver Spring, MD. Results Parallel to mammographic analysis in humans, measurements of rodent mammary gland density were derived from area-based or volume-based algorithms and included: total circumscribed mammary fat pad mass, mammary epithelial mass, and epithelium-free fat pad mass. These values permitted estimation of absolute mass of mammary epithelium as well as breast density. The biological plausibility of these measurements was evaluated in mammary whole mounts from rats and mice. During mammary gland development, absolute epithelial mass increased linearly without significant changes in mammographic density. Treatment of rodents with tamoxifen, 9-cis-retinoic acid, or ovariectomy, and occurrence of diet induced obesity decreased both absolute epithelial mass and mammographic density. The area and volumetric methods gave similar results. Conclusions Digital image analysis can be used for screening agents for potential impact on reproductive toxicity or carcinogenesis as well as for mechanistic studies, particularly for cumulative effects on mammary epithelial mass as well as translational studies of mechanisms that explain the relationship between epithelial mass and cancer risk.

  4. Digital imaging improves upright stereotactic core biopsy of mammographic microcalcifications

    International Nuclear Information System (INIS)

    Whitlock, J.P.L.; Evans, A.J.; Burrell, H.C.; Pinder, S.E.; Ellis, I.O.; Blamey, R.W.; Wilson, A.R.M.

    2000-01-01

    AIM: This comparative study was carried out to assess the effect of using digital images compared to conventional film-screen mammography on the accuracy of core biopsy of microcalcifications using upright stereotactic equipment. MATERIALS AND METHODS: The biopsy results from a consecutive series of 104 upright stereotactic 14-gauge core biopsies performed with conventional X-ray (Group A) were compared with 40 biopsies carried out using stereotaxis with digital imaging (Group B). In all cases specimen radiography was performed and analysed for the presence of calcifications. Pathological correlation was then carried out with needle and surgical histology. RESULTS: The use of digital add-on equipment increased the radiographic calcification retrieval rate from 55 to 85% (P < 0.005). The absolute sensitivity of core biopsy in pure ductal carcinoma in situ (DCIS) cases rose from 34 to 69% (P < 0.03), with the complete sensitivity increasing from 52 to 94% (P < 0.005). For DCIS with or without an invasive component the absolute sensitivity rose from 41 to 67% (P = 0.052), while the complete sensitivity was 59% before and 86% after the introduction of digital imaging (P < 0.04). CONCLUSION: Digital equipment improves the performance of upright stereotactic core biopsy of microcalcifications, giving a significantly increased success rate in accurately obtaining calcifications. This leads to an improvement in absolute and complete sensitivity of core biopsy when diagnosing DCIS. Whitlock, J.P.L. (2000)

  5. A comprehensive tool for measuring mammographic density changes over time.

    Science.gov (United States)

    Eriksson, Mikael; Li, Jingmei; Leifland, Karin; Czene, Kamila; Hall, Per

    2018-06-01

    Mammographic density is a marker of breast cancer risk and diagnostics accuracy. Density change over time is a strong proxy for response to endocrine treatment and potentially a stronger predictor of breast cancer incidence. We developed STRATUS to analyse digital and analogue images and enable automated measurements of density changes over time. Raw and processed images from the same mammogram were randomly sampled from 41,353 healthy women. Measurements from raw images (using FDA approved software iCAD) were used as templates for STRATUS to measure density on processed images through machine learning. A similar two-step design was used to train density measures in analogue images. Relative risks of breast cancer were estimated in three unique datasets. An alignment protocol was developed using images from 11,409 women to reduce non-biological variability in density change. The protocol was evaluated in 55,073 women having two regular mammography screens. Differences and variances in densities were compared before and after image alignment. The average relative risk of breast cancer in the three datasets was 1.6 [95% confidence interval (CI) 1.3-1.8] per standard deviation of percent mammographic density. The discrimination was AUC 0.62 (CI 0.60-0.64). The type of image did not significantly influence the risk associations. Alignment decreased the non-biological variability in density change and re-estimated the yearly overall percent density decrease from 1.5 to 0.9%, p density measures was not influenced by mammogram type. The alignment protocol reduced the non-biological variability between images over time. STRATUS has the potential to become a useful tool for epidemiological studies and clinical follow-up.

  6. Contrast enhanced digital mammography: Is it useful in detecting lesions in edematous breast?

    Directory of Open Access Journals (Sweden)

    Noha Abd ElShafy ElSaid

    2015-09-01

    Conclusion: Dual-energy contrast-enhanced digital mammography is a useful technique in identification of lesions in mammographically dense edematous breasts and proved to be a useful tool in the follow-up of cases presenting by edema after conservative breast surgery and chemotherapy.

  7. Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis.

    Science.gov (United States)

    McDonald, Elizabeth S; McCarthy, Anne Marie; Akhtar, Amana L; Synnestvedt, Marie B; Schnall, Mitchell; Conant, Emily F

    2015-11-01

    Baseline mammography studies have significantly higher recall rates than mammography studies with available comparison examinations. Digital breast tomosynthesis reduces recalls when compared with digital mammographic screening alone, but many sites operate in a hybrid environment. To maximize the effect of screening digital breast tomosynthesis with limited resources, choosing which patient populations will benefit most is critical. This study evaluates digital breast tomosynthesis in the baseline screening population. Outcomes were compared for 10,728 women who underwent digital mammography screening, including 1204 (11.2%) baseline studies, and 15,571 women who underwent digital breast tomosynthesis screening, including 1859 (11.9%) baseline studies. Recall rates, cancer detection rates, and positive predictive values were calculated. Logistic regression estimated the odds ratios of recall for digital mammography versus digital breast tomosynthesis for patients undergoing baseline screening and previously screened patients, adjusted for age, race, and breast density. In the baseline subgroup, recall rates for digital mammography and digital breast tomosynthesis screening were 20.5% and 16.0%, respectively (p = 0.002); digital breast tomosynthesis screening in the baseline subgroup resulted in a 22% reduction in recall compared with digital mammography, or 45 fewer patients recalled per 1000 patients screened. Digital breast tomosynthesis screening in the previously screened patients resulted in recall reduction of 14.3% (p tomosynthesis than from digital mammography alone.

  8. Comparison of synthetic mammography, reconstructed from digital breast tomosynthesis, and digital mammography: evaluation of lesion conspicuity and BI-RADS assessment categories.

    Science.gov (United States)

    Mariscotti, Giovanna; Durando, Manuela; Houssami, Nehmat; Fasciano, Mirella; Tagliafico, Alberto; Bosco, Davide; Casella, Cristina; Bogetti, Camilla; Bergamasco, Laura; Fonio, Paolo; Gandini, Giovanni

    2017-12-01

    To compare the interpretive performance of synthetic mammography (SM), reconstructed from digital breast tomosynthesis (DBT), and full-field digital mammography (FFDM) in a diagnostic setting, covering different conditions of breast density and mammographic signs. A retrospective analysis was conducted on 231 patients, who underwent FFDM and DBT (from which SM images were reconstructed) between September 2014-September 2015. The study included 250 suspicious breast lesions, all biopsy proven: 148 (59.2%) malignant and 13 (5.2%) high-risk lesions were confirmed by surgery, 89 (35.6%) benign lesions had radiological follow-up. Two breast radiologists, blinded to histology, independently reviewed all cases. Readings were performed with SM alone, then with FFDM, collecting data on: probability of malignancy for each finding, lesion conspicuity, mammographic features and dimensions of detected lesions. Agreement between readers was good for BI-RADS classification (Cohen's k-coefficient = 0.93 ± 0.02) and for lesion dimension (Wilcoxon's p = 0.76). Visibility scores assigned to SM and FFDM for each lesion were similar for non-dense and dense breasts, however, there were significant differences (p = 0.0009) in distribution of mammographic features subgroups. SM and FFDM had similar sensitivities in non-dense (respectively 94 vs. 91%) and dense breasts (88 vs. 80%) and for all mammographic signs (93 vs. 87% for asymmetric densities, 96 vs. 75% for distortion, 92 vs. 85% for microcalcifications, and both 94% for masses). Based on all data, there was a significant difference in sensitivity for SM (92%) vs. FFDM (87%), p = 0.02, whereas the two modalities yielded similar results for specificity (SM: 60%, FFDM: 62%, p = 0.21). SM alone showed similar interpretive performance to FFDM, confirming its potential role as an alternative to FFDM in women having tomosynthesis, with the added advantage of halving the patient's dose exposure.

  9. Acceptance testing in digital systems of mammography. Protocols applicability; Pruebas de aceptacion en equipos digitales de mamografia. Aplicabilidad de protocolos

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez, R.; Espana, M.L.; Garcia Castanon, P.; Gomez Barrado, A.; Rodriguez Martin, G.; Fernandez Bedoya, B.

    2011-07-01

    Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure control compensation and the detector noise, were found out to meet or not the limiting value, depending on the selected protocol. From our results we could suggest, that protocols from manufacturers should be adapted to acknowledged documents on acceptance testing in digital mammography. They buyer representative could even specify the protocol to be followed during the acceptance tests. (Author). 25 refs.

  10. The impact of mammographic screening on breast cancer mortality in Europe

    DEFF Research Database (Denmark)

    Moss, S M; Nyström, L; Jonsson, H.

    2012-01-01

    Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value.......Analysing trends in population breast cancer mortality statistics appears a simple method of estimating the effectiveness of mammographic screening programmes. We reviewed such studies of population-based screening in Europe to assess their value....

  11. Digital breast tomosynthesis; Digitale Tomosynthese der Brust

    Energy Technology Data Exchange (ETDEWEB)

    Haegele, Julian; Barkhausen, Joerg [Universtiaetsklinikum Schleswig-Holstein, Luebeck (Germany). Klinik fuer Radiologie und Nuklearmedizin; Pursche, Telja [Universtiaetsklinikum Schleswig-Holstein, Luebeck (Germany). Brustzentrum; Schaefer, Fritz K.W. [Universtiaetsklinikum Schleswig-Holstein, Kiel (Germany). Bereich Mammadiagnostik und Intervention

    2015-09-15

    In digital breast tomosynthesis a digital tomographic data set with a very high spatial resolution is reconstructed from low-dose projections collected over a limited rotation angle. This allows a very detailed assessment of e. g. masses and architectural distortions. The average glandular dose is comparable to 2 D mammography. First clinical studies demonstrated that tomosynthesis is able to supply important additional information in suspicious mammographic findings. In comparison to projection mammography, tomosynthesis shows an at least comparable diagnostic accuracy. In everyday practice, tomosynthesis is currently mostly used for further evaluation of suspicious findings in mammography.

  12. Resolution effects on the morphology of calcifications in digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Kallergi, Maria; He, Li; Gavrielides, Marios; Heine, John; Clarke, Laurence P [Department of Radiology, College of Medicine, and H. Lee Moffitt Cancer Center and Research Institute at the University of South Florida, 12901 Bruce B. Downs Blvd., Box 17, Tampa, FL 33612 (United States)

    1999-12-31

    The development of computer assisted diagnosis (CAD) techniques and direct digital mammography systems have generated significant interest in the issue of the effect of image resolution on the detection and classification (benign vs malignant) of mammographic abnormalities. CAD in particular seems to heavily depend on image resolution, either due to the inherent algorithm design and optimization, which is almost always dependent, or due to the differences in image content at the various resolutions. This twofold dependence makes it even more difficult to answer the question of what is the minimum resolution required for successful detection and/or classification of a specific mammographic abnormality, such as calcifications. One may begin by evaluating the losses in the mammograms as the films are digitized with different pixel sizes and depths. In this paper we attempted to measure these losses for the case of calcifications at four different spatial resolutions through a simulation model and a classification scheme that is based only on morphological features. The results showed that a 60 {mu}m pixel size and 12 bits per pixel should at least be used if the morphology and distribution of the calcifications are essential components in the CAD algorithm design. These conclusions were tested with the use of a wavelet-based algorithm for the segmentation of simulated mammographic calcifications at various resolutions. The evaluation of the segmentation through shape analysis and classification supported the initial conclusion. (authors) 14 refs., 1 tabs.

  13. Scattering influence in mammographic image

    International Nuclear Information System (INIS)

    Poletti, Martin Eduardo; Almeida, Adelaide de

    1996-01-01

    The quantification of mammographic images affected by scattered radiation is studied. The average glandular dose as a function of kVp and breast thickness for breast composition 50/50% is also evaluated. The results show that the contrast decreases with increasing of kVp and breast thickness, and the average glandular dose increase with increasing breast thickness and decreases with increasing kVp

  14. Background risk of breast cancer and the association between physical activity and mammographic density.

    Science.gov (United States)

    Trinh, Thang; Eriksson, Mikael; Darabi, Hatef; Bonn, Stephanie E; Brand, Judith S; Cuzick, Jack; Czene, Kamila; Sjölander, Arvid; Bälter, Katarina; Hall, Per

    2015-04-02

    High physical activity has been shown to decrease the risk of breast cancer, potentially by a mechanism that also reduces mammographic density. We tested the hypothesis that the risk of developing breast cancer in the next 10 years according to the Tyrer-Cuzick prediction model influences the association between physical activity and mammographic density. We conducted a population-based cross-sectional study of 38,913 Swedish women aged 40-74 years. Physical activity was assessed using the validated web-questionnaire Active-Q and mammographic density was measured by the fully automated volumetric Volpara method. The 10-year risk of breast cancer was estimated using the Tyrer-Cuzick (TC) prediction model. Linear regression analyses were performed to assess the association between physical activity and volumetric mammographic density and the potential interaction with the TC breast cancer risk. Overall, high physical activity was associated with lower absolute dense volume. As compared to women with the lowest total activity level (association was seen for any type of physical activity among women with association between total activity and absolute dense volume was modified by the TC breast cancer risk (P interaction = 0.05). As anticipated, high physical activity was also associated with lower non-dense volume. No consistent association was found between physical activity and percent dense volume. Our results suggest that physical activity may decrease breast cancer risk through reducing mammographic density, and that the physical activity needed to reduce mammographic density may depend on background risk of breast cancer.

  15. Bilateral breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Oh, Ki Keun; Jun, Hwang Yoon; Lee, Byung Chan; Lee, Kyong Sik; Lee, Yong Hee

    1997-01-01

    To evaluate the mammographic and clinical features of bilateral breast cancer. We retrospectively reviewed clinical records(n=23) and mammograms (n=15) of 23 patients with bilateral breast cancer. Patients' age, location of the tumor and pathologic staging were determined from clinical records. Mammographic features were classified as spiculated mass, nonspiculated mass, mass with microcalcification, microcalcification only, asymmetric density, and normal. Of the 23 cases of bilateral breast cancer, 8(34.8%) were synchronous and 15(65.2%) were metachronous. Age at diagnosis of cancer in the first breast was between 27 and 59(mean 43) years ; there was no statistically significant difference in mean age between patients with synchronous and metachronous cancer. The mean interval between the diagnosis of each lesion of the metachronous pairs was 9.1 years. In 11 of 23 cases(48%), tumors were locaated in the same quadrant, and in the other 12 cases(52%), they were in different quadrant. At mammography, five of 15 metachronous cancers(33%) were similar in appearance and 10 pairs(67%) were different. In 4 of 23 cases(17%), cancer in the first breast was at stage 0 and stage 1, and in 13 of 23(57%), cancer in the second breast was at this same stage. In bilateral breast cancer, the two breasts frequently show different mammographic features. Cancer of the second breast was at an early stage; this suggest that regular examination and mammography are important and can allow early detection of contralateral breast cancer

  16. Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

    Science.gov (United States)

    Vedantham, S; Karellas, A; Suryanarayanan, S; D'Orsi, C J; Hendrick, R E

    2000-11-01

    An amorphous silicon-based full-breast imager for digital mammography was evaluated for detector stability over a period of 1 year. This imager uses a structured CsI:TI scintillator coupled to an amorphous silicon layer with a 100-micron pixel pitch and read out by special purpose electronics. The stability of the system was characterized using the following quantifiable metrics: conversion factor (mean number of electrons generated per incident x-ray), presampling modulation transfer function (MTF), detector linearity and sensitivity, detector signal-to-noise ratio (SNR), and American College of Radiology (ACR) accreditation phantom scores. Qualitative metrics such as flat field uniformity, geometric distortion, and Society of Motion Picture and Television Engineers (SMPTE) test pattern image quality were also used to study the stability of the system. Observations made over this 1-year period indicated that the maximum variation from the average of the measurements were less than 0.5% for conversion factor, 3% for presampling MTF over all spatial frequencies, 5% for signal response, linearity and sensitivity, 12% for SNR over seven locations for all 3 target-filter combinations, and 0% for ACR accreditation phantom scores. ACR mammographic accreditation phantom images indicated the ability to resolve 5 fibers, 4 speck groups, and 5 masses at a mean glandular dose of 1.23 mGy. The SMPTE pattern image quality test for the display monitors used for image viewing indicated ability to discern all contrast steps and ability to distinguish line-pair images at the center and corners of the image. No bleeding effects were observed in the image. Flat field uniformity for all 3 target-filter combinations displayed no artifacts such as gridlines, bad detector rows or columns, horizontal or vertical streaks, or bad pixels. Wire mesh screen images indicated uniform resolution and no geometric distortion.

  17. Digital remote viewing system for coronary care unit

    International Nuclear Information System (INIS)

    Cho, P.S.; Tillisch, J.; Huang, H.K.

    1987-01-01

    A digital remote viewing system developed for the coronary care unit at the UCLA Medical Center has been in clinical operation since March 1, 1987. The present system consists of three 512-line monitors, VAX 11/750, Gould IP8500 image processor and a broad-band communication system. The patients' images are acquired with a computed radiography system and are transmitted to the coronary care unit, which is five floors above the radiology department. This exhibit presents the architecture and the performance characteristics of the system. Also, the second-generation system, which consists of an intelligent local work station with three 1,024-line monitors and a fast digital communication network, will be introduced

  18. Generation of CR mammographic image for evaluation quality parameters

    International Nuclear Information System (INIS)

    Flores, Mabel B.; Mourao, Arnaldo P.; Centro Federal de Educacao Tecnologica de Minas Gerais

    2017-01-01

    Currently, among the diseases most feared by women, breast cancer ranks first in the world with an incidence of more than 1.6 million cases and a mortality of more than 521.9 thousand cases by year, which makes this disease the type of cancer with higher incidence and mortality compared to the other types of cancer that mainly affect the female gender, without considering non-melanoma skin cancer. In Brazil, more than 14.4 thousand deaths were registered in 2013 and more than 57 thousand new cases were estimated for 2016. The use of computerized radiography (CR) for the generation of mammographic digital images is widely used in Brazil for the screening of breast cancer. The aim of this investigation is to study the variation of CR plate response to exposure to X-ray beams in a mammography unit. Two CR plates from different manufacturers and a compressed breast phantom containing calcium carbonate structures of different sizes simulating calcifications were used for this study. An X-ray beam generated by 30 kV was selected to realize successive exposures of each plate by performing a time variation of 0.5 to 3.5 s, obtaining the raw images. The acquired images were evaluated with the ImageJ software to determine the saturation time of the plates when exposed to X-ray beams and the qualitative resolution of each plate. The plates were found to saturate at different times when exposed under the same conditions to X-ray beams. By means of the images acquired with the breast phantom, it was possible to observe only structures of calcium carbonate with sizes greater than 177 μm. (author)

  19. Generation of CR mammographic image for evaluation quality parameters

    Energy Technology Data Exchange (ETDEWEB)

    Flores, Mabel B.; Mourao, Arnaldo P., E-mail: mbustos@ufmg.br, E-mail: apratabhz@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educacao Tecnologica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Politecnica

    2017-11-01

    Currently, among the diseases most feared by women, breast cancer ranks first in the world with an incidence of more than 1.6 million cases and a mortality of more than 521.9 thousand cases by year, which makes this disease the type of cancer with higher incidence and mortality compared to the other types of cancer that mainly affect the female gender, without considering non-melanoma skin cancer. In Brazil, more than 14.4 thousand deaths were registered in 2013 and more than 57 thousand new cases were estimated for 2016. The use of computerized radiography (CR) for the generation of mammographic digital images is widely used in Brazil for the screening of breast cancer. The aim of this investigation is to study the variation of CR plate response to exposure to X-ray beams in a mammography unit. Two CR plates from different manufacturers and a compressed breast phantom containing calcium carbonate structures of different sizes simulating calcifications were used for this study. An X-ray beam generated by 30 kV was selected to realize successive exposures of each plate by performing a time variation of 0.5 to 3.5 s, obtaining the raw images. The acquired images were evaluated with the ImageJ software to determine the saturation time of the plates when exposed to X-ray beams and the qualitative resolution of each plate. The plates were found to saturate at different times when exposed under the same conditions to X-ray beams. By means of the images acquired with the breast phantom, it was possible to observe only structures of calcium carbonate with sizes greater than 177 μm. (author)

  20. Dose and risk evaluation in digital mammography using computer modeling

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Samanda Cristine Arruda; Souza, Edmilson Monteiro de, E-mail: scorrea@nuclear.ufrj.b, E-mail: emonteiro@nuclear.ufrj.b [Centro Universitario Estadual da Zona Oeste (CCMAT/UEZO), Rio de Janeiro, RJ (Brazil); Silva, Humberto de Oliveira, E-mail: hbetorj@gmail.co [Universidade Federal do Rio de Janeiro IF/UFRJ, RJ (Brazil). Inst. de Fisica; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu; Magalhaes, Sarah Braga, E-mail: ademir@nuclear.ufrj.b, E-mail: ricardo@lin.ufrj.b, E-mail: smagalhaes@nuclear.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear

    2010-07-01

    Digital mammography has been introduced in several countries in the last years. The new technology requires new optimising methods considering for instance the increased possibility of changing the absorbed dose, mainly in modern mammographic systems that allow the operator to choose the beam quality by varying the tube voltage, and filter and target materials. In this work, the Monte Carlo code MCNPX is used in order to investigate how the average glandular dose vary with tube voltage (23-32 kV) and anode-filter combination (Mo-Mo,Mo-Rh and Rh-Rh) in digital mammographic examinations. Furthermore, the risk of breast cancer incidence attributable to mammography exams was estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The results show that the risk of breast cancer incidence in women younger than 30 years of age tends to decrease significantly using Rh-Rh anode-filter combination and higher tube voltage. For women older than 50 years of age the variation of tube voltage, and anode-filter combination did not influence the risk values considerably. (author)

  1. Dose and risk evaluation in digital mammography using computer modeling

    International Nuclear Information System (INIS)

    Correa, Samanda Cristine Arruda; Souza, Edmilson Monteiro de; Silva, Humberto de Oliveira; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu; Magalhaes, Sarah Braga

    2010-01-01

    Digital mammography has been introduced in several countries in the last years. The new technology requires new optimising methods considering for instance the increased possibility of changing the absorbed dose, mainly in modern mammographic systems that allow the operator to choose the beam quality by varying the tube voltage, and filter and target materials. In this work, the Monte Carlo code MCNPX is used in order to investigate how the average glandular dose vary with tube voltage (23-32 kV) and anode-filter combination (Mo-Mo,Mo-Rh and Rh-Rh) in digital mammographic examinations. Furthermore, the risk of breast cancer incidence attributable to mammography exams was estimated using the Biological Effects of Ionizing Radiations (BEIR) VII Committee Report. The results show that the risk of breast cancer incidence in women younger than 30 years of age tends to decrease significantly using Rh-Rh anode-filter combination and higher tube voltage. For women older than 50 years of age the variation of tube voltage, and anode-filter combination did not influence the risk values considerably. (author)

  2. Decision trees and integrated features for computer aided mammographic screening

    Energy Technology Data Exchange (ETDEWEB)

    Kegelmeyer, W.P. Jr.; Groshong, B.; Allmen, M.; Woods, K.

    1997-02-01

    Breast cancer is a serious problem, which in the United States causes 43,000 deaths a year, eventually striking 1 in 9 women. Early detection is the only effective countermeasure, and mass mammography screening is the only reliable means for early detection. Mass screening has many shortcomings which could be addressed by a computer-aided mammographic screening system. Accordingly, we have applied the pattern recognition methods developed in earlier investigations of speculated lesions in mammograms to the detection of microcalcifications and circumscribed masses, generating new, more rigorous and uniform methods for the detection of both those signs. We have also improved the pattern recognition methods themselves, through the development of a new approach to combinations of multiple classifiers.

  3. Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

    International Nuclear Information System (INIS)

    Sadaf, Arifa; Crystal, Pavel; Scaranelo, Anabel; Helbich, Thomas

    2011-01-01

    Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers.

  4. The clinical and mammographic features of plasma cell mastitis

    International Nuclear Information System (INIS)

    Wu Xiurong; Luo Xiaohua; Yu Xuming; Zhong Shan; Huang Yufan; Wu Xinyi; Lin Yubin

    2007-01-01

    Objective: To investigate the clinical and mammographic features of plasma cell mastitis. Methods: Twenty-five patients (28 lesions) with histologically confirmed plasma cell mastitis, aged from 26 to 70 years (mean age 41 years), were examined with X-ray mammography. The clinical manifestations and imaging features were retrospectively reviewed. Results: No case was in lactation. The painful irregular masses, ranged from 1.3 to 8cm in size, were found in 22 patients, while 3 patients with acute episode. Recurrent episodes of breast masses were noted in 4 patients. Based on the mammographic appearances, the plasma cell mastitis were classified as the following four types: inflammation-like type (2/28), ductal ectasia type (3/28), focal infiltration type (10/28) and nodular type (13/28). The valuable radiographic signs: (1) An asymmetrically increased density along the lactiferous duct with a flame-like appearance, inhomogeneous low density tubular structures and scattered stick-shape calcifications. (2) Architectural distortion and oil cysts formation in adjacent area, (3) Subareolar ductal ectasia. Conclusions: The clinical and mammographic characteristics of plasma cell mastitis are critical to avoiding unnecessary surgery. Histopathological result is needed for the diagnosis in patients highly suspected of malignancy. (authors)

  5. Bilateral mammographic density asymmetry and breast cancer risk: A preliminary assessment

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Bin, E-mail: zhengb@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Sumkin, Jules H., E-mail: jsumkin@mail.magee.edu [Department of Radiology, Magee Womens Hospital, 300 Halket Street, Pittsburgh, PA 15213 (United States); Zuley, Margarita L., E-mail: zuleyml@upmc.edu [Department of Radiology, Magee Womens Hospital, 300 Halket Street, Pittsburgh, PA 15213 (United States); Wang, Xingwei, E-mail: wangx6@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Klym, Amy H., E-mail: klymah@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States); Gur, David, E-mail: gurd@upmc.edu [Department of Radiology, University of Pittsburgh, 3362 Fifth Ave, Pittsburgh, PA 15213 (United States)

    2012-11-15

    To improve efficacy of breast cancer screening and prevention programs, it requires a risk assessment model with high discriminatory power. This study aimed to assess classification performance of using computed bilateral mammographic density asymmetry to predict risk of individual women developing breast cancer in near-term. The database includes 451 cases with multiple screening mammography examinations. The first (baseline) examinations of all case were interpreted negative. In the next sequential examinations, 187 cases developed cancer or surgically excised high-risk lesions, 155 remained negative (not-recalled), and 109 were recalled benign cases. From each of two bilateral cranio-caudal view images acquired from the baseline examination, we computed two features of average pixel value and local pixel value fluctuation. We then computed mean and difference of each feature computed from two images. When applying the computed features and other two risk factors (woman's age and subjectively rated mammographic density) to predict risk of cancer development, areas under receiver operating characteristic curves (AUC) were computed to evaluate the discriminatory/classification performance. The AUCs are 0.633 {+-} 0.030, 0.535 {+-} 0.036, 0.567 {+-} 0.031, and 0.719 {+-} 0.027 when using woman's age, subjectively rated, computed mean and asymmetry of mammographic density, to classify between two groups of cancer-verified and negative cases, respectively. When using an equal-weighted fusion method to combine woman's age and computed density asymmetry, AUC increased to 0.761 {+-} 0.025 (p < 0.05). The study demonstrated that bilateral mammographic density asymmetry could be a significantly stronger risk factor associated to the risk of women developing breast cancer in near-term than woman's age and assessed mean mammographic density.

  6. Bilateral mammographic density asymmetry and breast cancer risk: A preliminary assessment

    International Nuclear Information System (INIS)

    Zheng, Bin; Sumkin, Jules H.; Zuley, Margarita L.; Wang, Xingwei; Klym, Amy H.; Gur, David

    2012-01-01

    To improve efficacy of breast cancer screening and prevention programs, it requires a risk assessment model with high discriminatory power. This study aimed to assess classification performance of using computed bilateral mammographic density asymmetry to predict risk of individual women developing breast cancer in near-term. The database includes 451 cases with multiple screening mammography examinations. The first (baseline) examinations of all case were interpreted negative. In the next sequential examinations, 187 cases developed cancer or surgically excised high-risk lesions, 155 remained negative (not-recalled), and 109 were recalled benign cases. From each of two bilateral cranio-caudal view images acquired from the baseline examination, we computed two features of average pixel value and local pixel value fluctuation. We then computed mean and difference of each feature computed from two images. When applying the computed features and other two risk factors (woman's age and subjectively rated mammographic density) to predict risk of cancer development, areas under receiver operating characteristic curves (AUC) were computed to evaluate the discriminatory/classification performance. The AUCs are 0.633 ± 0.030, 0.535 ± 0.036, 0.567 ± 0.031, and 0.719 ± 0.027 when using woman's age, subjectively rated, computed mean and asymmetry of mammographic density, to classify between two groups of cancer-verified and negative cases, respectively. When using an equal-weighted fusion method to combine woman's age and computed density asymmetry, AUC increased to 0.761 ± 0.025 (p < 0.05). The study demonstrated that bilateral mammographic density asymmetry could be a significantly stronger risk factor associated to the risk of women developing breast cancer in near-term than woman's age and assessed mean mammographic density.

  7. Association of Catechol-O-methyltransferase polymorphism Val158Met and mammographic density: A meta-analysis.

    Science.gov (United States)

    Kallionpää, Roope A; Uusitalo, Elina; Peltonen, Juha

    2017-08-15

    The Val158Met polymorphism in catechol-O-methyltransferase (COMT) enzyme reduces the methylation of catechol estrogens, which may affect mammographic density. High mammographic density is a known risk factor of breast cancer. Our aim was to perform meta-analysis of the effect of COMT Val158Met polymorphism on mammographic density. Original studies reporting data on mammographic density, stratified by the presence of COMT Val158Met polymorphism, were identified and combined using genetic models Met/Val vs. Val/Val, Met/Met vs. Val/Val, Val/Met+Met/Met vs. Val/Val (dominant model) and Met/Met vs. Val/Met+Val/Val (recessive model). Subgroup analyses by breast cancer status, menopausal status and use of hormone replacement therapy (HRT) were also performed. Eight studies were included in the meta-analysis. The overall effect in percent mammographic density was -1.41 (CI -2.86 to 0.05; P=0.06) in the recessive model. Exclusion of breast cancer patients increased the effect size to -1.93 (CI -3.49 to -0.37; P=0.02). The results suggested opposite effect of COMT Val158Met for postmenopausal users of HRT versus premenopausal women or postmenopausal non-users of HRT. COMT Val158Met polymorphism may be associated with mammographic density at least in healthy women. Menopausal status and HRT should be taken into account in future studies to avoid masking of the underlying effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Mammographic varicosities indicative of a superior mediastinal ...

    African Journals Online (AJOL)

    In addition, an abnormal calibre of the superficial veins can reflect not only underrying breast pathology, but a collateral venous return resulting from an upper mediastinal obstruction. A case mammographically demonstrating mammary varicosities resulting from a superior mediastinal syndrome is described. S. Afr. Med.

  9. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  10. Mammographic compression – A need for mechanical standardization

    Energy Technology Data Exchange (ETDEWEB)

    Branderhorst, Woutjan, E-mail: w.branderhorst@amc.nl [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Sigmascreening B.V., Meibergdreef 45, 1105 BA Amsterdam (Netherlands); Groot, Jerry E. de, E-mail: jerry.degroot@sigmascreening.com [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Highnam, Ralph, E-mail: ralph.highnam@volparasolutions.com [Volpara Solutions Limited, P.O. Box 24404, Manners St Central, Wellington 6142 (New Zealand); Chan, Ariane, E-mail: ariane.chan@volparasolutions.com [Volpara Solutions Limited, P.O. Box 24404, Manners St Central, Wellington 6142 (New Zealand); Böhm-Vélez, Marcela, E-mail: marcelabvelez@gmail.com [Weinstein Imaging Associates, 5850 Centre Avenue, Pittsburgh, PA 15206 (United States); Broeders, Mireille J.M., E-mail: mireille.broeders@radboudumc.nl [Radboud University Medical Center, Department for Health Evidence, P.O. Box 9101, 6500 HB Nijmegen (Netherlands); LRCB Dutch Reference Center for Screening, P.O. Box 6873, 6503 GJ Nijmegen (Netherlands); Heeten, Gerard J. den, E-mail: g.denheeten@lrcb.nl [Academic Medical Center, Department of Radiology, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); LRCB Dutch Reference Center for Screening, P.O. Box 6873, 6503 GJ Nijmegen (Netherlands); Grimbergen, Cornelis A., E-mail: c.a.grimbergen@amc.uva.nl [Academic Medical Center, Department of Biomedical Engineering & Physics, P.O. Box 22660, 1100 DD Amsterdam (Netherlands); Sigmascreening B.V., Meibergdreef 45, 1105 BA Amsterdam (Netherlands)

    2015-04-15

    Highlights: •We studied mechanical breast compression practice in two different clinical sites. •We visualized the distributions of not only the applied force but also the pressure. •The applied pressure was highly variable, both within and between the data sets. •The average applied pressure and the variation were higher for smaller breasts. •A proposal for improved individualization, by standardizing pressure, is discussed. -- Abstract: Background: A lack of consistent guidelines regarding mammographic compression has led to wide variation in its technical execution. Breast compression is accomplished by means of a compression paddle, resulting in a certain contact area between the paddle and the breast. This procedure is associated with varying levels of discomfort or pain. On current mammography systems, the only mechanical parameter available in estimating the degree of compression is the physical entity of force (daN). Recently, researchers have suggested that pressure (kPa), resulting from a specific force divided by contact area on a breast, might be a more appropriate parameter for standardization. Software has now become available which enables device-independent cross-comparisons of key mammographic metrics, such as applied compression pressure (force divided by contact area), breast density and radiation dose, between patient populations. Purpose: To compare the current compression practice in mammography between different imaging sites in the Netherlands and the United States from a mechanical point of view, and to investigate whether the compression protocols in these countries can be improved by standardization of pressure (kPa) as an objective mechanical parameter. Materials and methods: We retrospectively studied the available parameters of a set of 37,518 mammographic compressions (9188 women) from the Dutch national breast cancer screening programme (NL data set) and of another set of 7171 compressions (1851 women) from a breast imaging

  11. Classified one-step high-radix signed-digit arithmetic units

    Science.gov (United States)

    Cherri, Abdallah K.

    1998-08-01

    High-radix number systems enable higher information storage density, less complexity, fewer system components, and fewer cascaded gates and operations. A simple one-step fully parallel high-radix signed-digit arithmetic is proposed for parallel optical computing based on new joint spatial encodings. This reduces hardware requirements and improves throughput by reducing the space-bandwidth produce needed. The high-radix signed-digit arithmetic operations are based on classifying the neighboring input digit pairs into various groups to reduce the computation rules. A new joint spatial encoding technique is developed to present both the operands and the computation rules. This technique increases the spatial bandwidth product of the spatial light modulators of the system. An optical implementation of the proposed high-radix signed-digit arithmetic operations is also presented. It is shown that our one-step trinary signed-digit and quaternary signed-digit arithmetic units are much simpler and better than all previously reported high-radix signed-digit techniques.

  12. Clinical evaluation of digital displays for PACS work stations

    International Nuclear Information System (INIS)

    Highman, J.H.; Craig, J.O.M.C.; Dawood, R.M.; Todd-Pokropek, A.; Porter, A.; Glass, H.I.; Wadsworth, J.

    1989-01-01

    The requirements for display of radiographic images at PAVS work stations is critical if reporting at CRT terminal is to become routine practice. This study determines the accuracy of reporting for the digital images displayed on commercially available systems. A number of pathologic conditions were selected by virtue of the high demands they made on spatial and contrast resolution. They included hyperparathyroid subperiosteal resorption in the hands, pneumocystis pneumonia, and mammographic microcalcification. For each condition, a series of up to 100 films were collected; approximately half were normal controls. These were digitized at 200 μm. Original films and their digitized images displayed on a 1,280-line monitor have been reported

  13. Digital Radiology Image Learning Library

    International Nuclear Information System (INIS)

    Arenson, R.L.; Greenes, R.; Allman, R.; Swett, H.

    1989-01-01

    The Digital Radiology Image Learning Library (DRILL) is designed as an interactive teaching tool targeted to the radiologic community. The DRILL pilot comprises a comprehensive mammographic information base consisting of factual data in a relational database, an extensive knowledge base in semantic nets and high-resolution images. A flexible query module permits the user to browse and retrieve examination data, case discussions, and related images. Other applications, including expert systems, instructional programs, and skill building exercises, can be accessed through well-defined software constructs

  14. Mammographic findings predicting an extensive intraductal component in early stage invasive breast cancer : analysis on microcalcification

    International Nuclear Information System (INIS)

    Kim, Jeong Ah; Kim, Mi Hye; Lee, Mi Kyung; Oh, Ki Keun; Kim, Eun Kyung

    2000-01-01

    To analyze the mammographic findings of extensive intraductal component (EIC)-positive early invasive breast carcinoma and to determine the mammographic features which predict an EIC positivity in an invasive carcinoma. The mammographic and pathologic findings in 71 patients aged 34-79 (mean 50) years in whom stage I or II invasive breast carcinoma had been diagnosed were retrospectively analysed. The mammographic findings were assigned to one of three groups: mass, mass with microcalcification, or microcalcification only. The shape and distribution of a calcification were classified according to the BI-RADS lexicon, and its extent was classified as either more or less than 3 cm. To detect the presence or absence of EIC and the type of ductal carcinoma in situ (DCIS), the findings were re-examined by means of slide mappings. Twenty-eight of 71 patients (39%) showed ECI positivity. The mammographic findings of EIC-positive invasive cancer (n=3D28) were mass with microcalcification (n=3D14), microcalcification only (n=3D7) and mass only (n=3D7). The mammographic finding which predicted EIC positivity was mass with microcalcification (PPV:0.67, NPV:0.33, p=3D0.02). A mammographic of mass only (n=3D39) showed a significantly high negative predictive value for EIC positivity. (PPV 0.18, NPV 0.82, P less than 0.01). A comparison of cases with or without calcification showed that those with microcalcifications (n=3D32) showed a significantly high PPV of 0.66 (NPV:0.34, p less than 0.01) while those without calcification (n=3D39) showed a significantly high NPV of 0.82 (PPV:0.18, p less than 0.01). There were no significant differences in positive predictive values for EIC between the shape, distribution and extent of calcifications. Whenever microcalcification with or without mass is seen on mammographs obtained during early breast cancer, we can predict EIC-positivity, regardless of shape or distribution according to the BI-RADS lexicon. (author)

  15. Comparative analysis among X-ray mammographic findings, nuclear and histologic grading, and TNM staging of breast carcinoma

    International Nuclear Information System (INIS)

    Park, Jin Sook; Sung, Ki Joon; Cho, Mee Yon; Hong, In Soo; Kim, Myung Soon; Oh, Ki Keun

    1996-01-01

    The purpose of this study was to evaluate the prognosis of breast carcinoma by comparison with X-ray mammographic findings, nuclear and histologic grade, and TNM staging. We retrospectively reviewed 114 cases (113 patients) of breast carcinoma, analysing X-ray mammographic findings of all cases with regard to mass, calcification, and spiculation. In 80 cases of scirrhous invasive ductal breast carcinoma. Black's nuclear and Bloom-Richardson's histologic grade were also evaluated. Mammographic findings and nuclear and histologic grade were compared with TNM staging which might suggest the prognosis of breast carcinoma. X-ray mammographic findings (mass, calcification and spiculation) did not significantly correlate with T staging, but the clinical staging of the spiculation was advanced. These X-ray findings did not significantly correlate with the nuclear grading and the histologic grading. Nuclear grade did not correlate with T and M staging, but correlated significantly with N staging and clinical stage(p < 0.05). Histologic grade did not significantly correlate with TNM staging. The clinical staging of spiculation was advanced and nuclear grade correlated significantly with N stage and clinical staging. X-ray mammographic findings did not directly correlate with nuclear and histologic grading, but combined studies of the evaluation of mammographic findings and nuclear and histologic grade were useful for prognosing breast carcinoma

  16. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia.

    Science.gov (United States)

    Chen, Po-Hao; Slanetz, Priscilla J

    2014-01-01

    To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. A total of 353 mammograms were obtained from 327 unique patients (ages 18-95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Incremental clinical value of ultrasound in men with mammographically confirmed gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Po-Hao, E-mail: howard_chen@post.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Department of Radiology, Hospital of University of Pennsylvania, 3400 Spruce Street, Philadlephia, PA 19104 (United States); Slanetz, Priscilla J., E-mail: pslanetz@bidmc.harvard.edu [Harvard Medical School, 25 Shattuck Street, Boston, MA 02115 (United States); Beth Israel Deaconess Medical Center, Department of Radiology, 330 Brookline Avenue, Boston, MA 02215 (United States)

    2014-01-15

    Purpose: To determine whether ultrasound is of any value in male patients presenting with focal symptoms who have classic features of gynecomastia but no concerning findings on mammography. Materials and Methods: Over a 3-year period, all male patients who underwent mammographic evaluation were identified in this retrospective study. Patients with a mammographic diagnosis of gynecomastia and subsequent breast ultrasound at a large tertiary academic medical center comprised the study cohort. Men whose ultrasound diagnosis differed from the initial mammographic evaluation were analyzed for both additional benign findings as well as findings that warranted biopsy. Results: A total of 353 mammograms were obtained from 327 unique patients (ages 18–95, mean 51 years). Of all mammographic examinations, gynecomastia was the sole finding in 73% (259). In those 259 studies, 85% were further evaluated with ultrasound, in which 6 (2.7%) showed additional benign findings, and 4 (1.8%) showed suspicious findings for which biopsy was recommended. No malignancies were detected in those patients. Furthermore, no malignancies were detected in patients whose mammogram revealed only normal fatty parenchyma or only gynecomastia. In all cases of cancer, mammography revealed visible masses. Conclusion: Judicious use of breast ultrasound in men improves outcome. Our data suggest that targeted ultrasound is of limited value in symptomatic male patients where mammography is negative or reveals only gynecomastia and leads to unnecessary benign biopsies in these patients. When mammography reveals concerning findings, ultrasound adds positively to clinical management.

  18. Ethnic Differences in Mammographic Densities: An Asian Cross-Sectional Study

    Science.gov (United States)

    Mariapun, Shivaani; Li, Jingmei; Yip, Cheng Har; Taib, Nur Aishah Mohd; Teo, Soo-Hwang

    2015-01-01

    Background Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. Methods A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. Results Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0%) compared to Malay (24.2%; 95% CI 22.5%, 26.0%) and Indian (24.3%; 95% CI 22.8%, 25.7%) women (p<0.001), after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2) women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2) and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2) women (p<0.001), but dense area did not differ across the three ethnic groups. Conclusions Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort. PMID:25659139

  19. Ethnic differences in mammographic densities: an Asian cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Shivaani Mariapun

    Full Text Available BACKGROUND: Mammographic density is a strong risk factor for breast cancer and is highly variable, but, to date, few studies have examined density in Asian women, particularly those in low and middle-income Asian countries where genetic and lifestyle determinants may be significantly different. METHODS: A total of 1,240 women who attended an opportunistic mammogram screening programme were eligible for analysis. Mammographic density was estimated using a fully-automated thresholding method and differences across ethnic groups were examined using linear regression in 205 randomly selected Chinese women, 138 Malay and 199 Indian women. RESULTS: Percent density was significantly higher in Chinese women (28.5%; 95% CI 27.0%, 30.0% compared to Malay (24.2%; 95% CI 22.5%, 26.0% and Indian (24.3%; 95% CI 22.8%, 25.7% women (p<0.001, after adjustment for age, BMI, menopausal status, parity and age at first full term pregnancy. Correspondingly, adjusted nondense area was significantly lower in Chinese (72.2cm2; 95% CI 67.9cm2, 76.5cm2 women compared to Malay (92.1cm2; 95% CI 86.9cm2, 97.2cm2 and Indian (97.7cm2; 95% CI 93.4cm2, 101.9cm2 women (p<0.001, but dense area did not differ across the three ethnic groups. CONCLUSIONS: Our study shows that higher percent density and lower nondense area reflect the higher incidence of breast cancer in Chinese compared to Malay and Indian women in Malaysia. Known lifestyle determinants of mammographic density do not fully account for the ethnic variations observed in mammographic density in this Asian cohort.

  20. Sclerosing adenosis: mammographic and ultrasonographic findings with clinical and histopathological correlation

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Memis, Aysenur; Uestuen, Esin Emin; Oezdemir, Necmettin; Erhan, Yildiz

    2002-01-01

    Objective: To evaluate the mammographic and ultrasonographic findings of sclerosing adenosis, a relatively uncommon entity which may sometimes mimic carcinoma. Materials and methods: A retrospective review of the records of 33700 women, who have undergone mammographic examination at our institution between January 1985 and July 2001 revealed 43 histopathologically proven sclerosing adenosis. The history, physical examination, mammographic and ultrasonographic findings were analyzed in all patients. In 30 patients, the nonpalpable lesions were preoperatively localized by the needle-hookwire system under the guidance of mammography (n=22) or ultrasonography (US) (n=8). Radiological features were correlated with histopathological findings. Results: The age of the patients varied between 32 and 55 years (mean, 43.7 years). Only two patients had a family history of breast cancer. In six patients, the presenting complaint was mastalgia. A palpable mass was present in 13 cases. The mammographic findings were; microcalcifications in 24 (55.8%) (clustered in 22, diffuse in two), mass in five (11.6%), asymmetric focal density in three (6.9%), and focal architectural distortion in three (6.9%) patients. Four of the masses were irregularly contoured, while one was well-circumscribed. On US, focal acoustic shadowing without a mass configuration was noted in the three patients who showed asymmetrical focal density on mammography. In eight patients, who showed normal mammograms, a solid mass was detected on US. Two masses had discrete well-circumscribed oval or lobulated contours, while six showed microlobulation and irregularity. In one case, the irregularly contoured mass had marked posterior acoustic shadowing. Two of the three patients, who had focal architectural distortion on mammograms, had an irregularly contoured solid mass, while the third presented as focal acoustic shadowing without a mass configuration. Conclusion: Sclerosing adenosis mostly presents as a nonpalpable

  1. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  2. Mammographer personality traits – elements of the optimal ...

    African Journals Online (AJOL)

    2014-11-07

    Nov 7, 2014 ... competency, good communication skills and the ability to limit patient anxiety and ... personality traits in mammographers in order of importance .... 1 (trust) is high, with a Cronbach's alpha of 0.911 and inter- item reliability ...

  3. Mammography and mammographic screening in the United Kingdom: Practices, regulations and radiation dosimetry

    International Nuclear Information System (INIS)

    Fitzgerald, M.

    1987-01-01

    The radiation-induced cancers due to mammography represent about 0.6 % of the natural incidence in this survey and would seem to be a very small risk. If the frequency or period of screening was increased, the risk would be enhanced. However, it should be possible to reduce the radiation dose to less than the mean value used here. For example, if film screen mammography alone was used for this population, the quoted risk would be reduced by 25%. The dose is also reduced by the use of a single view. The relatively low risk to the breast is a consequence partly of the low dose mammographic techniques that can now be practised, and partly of the acceptance of mean breast dose, which may be an order to magnitude less than the surface dose, as the measure of risk. The risk to other organs should be negligible provided that the X-ray field is carefully collimated and that the breast table incorporates a primary absorber

  4. Computerized analysis of mammographic parenchymal patterns for assessing breast cancer risk: Effect of ROI size and location

    International Nuclear Information System (INIS)

    Li Hui; Giger, Maryellen L.; Huo Zhimin; Olopade, Olufunmilayo I.; Lan Li; Weber, Barbara L.; Bonta, Ioana

    2004-01-01

    The long-term goal of our research is to develop computerized radiographic markers for assessing breast density and parenchymal patterns that may be used together with clinical measures for determining the risk of breast cancer and assessing the response to preventive treatment. In our earlier studies, we found that women at high risk tended to have dense breasts with mammographic patterns that were coarse and low in contrast. With our method, computerized texture analysis is performed on a region of interest (ROI) within the mammographic image. In our current study, we investigate the effect of ROI size and ROI location on the computerized texture features obtained from 90 subjects (30 BRCA1/BRCA2 gene-mutation carriers and 60 age-matched women deemed to be at low risk for breast cancer). Mammograms were digitized at 0.1 mm pixel size and various ROI sizes were extracted from different breast regions in the craniocaudal (CC) view. Seventeen features, which characterize the density and texture of the parenchymal patterns, were extracted from the ROIs on these digitized mammograms. Stepwise feature selection and linear discriminant analysis were applied to identify features that differentiate between the low-risk women and the BRCA1/BRCA2 gene-mutation carriers. ROC analysis was used to assess the performance of the features in the task of distinguishing between these two groups. Our results show that there was a statistically significant decrease in the performance of the computerized texture features, as the ROI location was varied from the central region behind the nipple. However, we failed to show a statistically significant decrease in the performance of the computerized texture features with decreasing ROI size for the range studied

  5. Fractal analysis of visual search activity for mass detection during mammographic screening.

    Science.gov (United States)

    Alamudun, Folami; Yoon, Hong-Jun; Hudson, Kathleen B; Morin-Ducote, Garnetta; Hammond, Tracy; Tourassi, Georgia D

    2017-03-01

    The objective of this study was to assess the complexity of human visual search activity during mammographic screening using fractal analysis and to investigate its relationship with case and reader characteristics. The study was performed for the task of mammographic screening with simultaneous viewing of four coordinated breast views as typically done in clinical practice. Eye-tracking data and diagnostic decisions collected for 100 mammographic cases (25 normal, 25 benign, 50 malignant) from 10 readers (three board certified radiologists and seven Radiology residents), formed the corpus for this study. The fractal dimension of the readers' visual scanning pattern was computed with the Minkowski-Bouligand box-counting method and used as a measure of gaze complexity. Individual factor and group-based interaction ANOVA analysis was performed to study the association between fractal dimension, case pathology, breast density, and reader experience level. The consistency of the observed trends depending on gaze data representation was also examined. Case pathology, breast density, reader experience level, and individual reader differences are all independent predictors of the complexity of visual scanning pattern when screening for breast cancer. No higher order effects were found to be significant. Fractal characterization of visual search behavior during mammographic screening is dependent on case properties and image reader characteristics. © 2017 American Association of Physicists in Medicine.

  6. Low energy mammogram obtained in contrast-enhanced digital mammography (CEDM) is comparable to routine full-field digital mammography (FFDM)

    Energy Technology Data Exchange (ETDEWEB)

    Francescone, Mark A., E-mail: maf2184@columbia.edu [Columbia University Medical Center, ColumbiaDoctors Midtown, 51 West 51st Street, Suite 300, New York, NY 10019 (United States); Jochelson, Maxine S., E-mail: jochelsm@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Dershaw, D. David, E-mail: dershawd@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Sung, Janice S., E-mail: sungj@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Hughes, Mary C., E-mail: hughesm@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Zheng, Junting, E-mail: zhengj@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Moskowitz, Chaya, E-mail: moskowc1@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Morris, Elizabeth A., E-mail: morrise@mskcc.org [Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States)

    2014-08-15

    Purpose: Contrast enhanced digital mammography (CEDM) uses low energy and high energy exposures to produce a subtracted contrast image. It is currently performed with a standard full-field digital mammogram (FFDM). The purpose is to determine if the low energy image performed after intravenous iodine injection can replace the standard FFDM. Methods: And Materials: In an IRB approved HIPAA compatible study, low-energy CEDM images of 170 breasts in 88 women (ages 26–75; mean 50.3) undergoing evaluation for elevated risk or newly diagnosed breast cancer were compared to standard digital mammograms performed within 6 months. Technical parameters including posterior nipple line (PNL) distance, compression thickness, and compression force on the MLO projection were compared. Mammographic findings were compared qualitatively and quantitatively. Mixed linear regression using generalized estimating equation (GEE) method was performed. Intraclass correlation coefficients (ICC) with 95% confidence interval (95%CI) were estimated to assess agreement. Results: No statistical difference was found in the technical parameters compression thickness, PNL distance, compression force (p-values: 0.767, 0.947, 0.089). No difference was found in the measured size of mammographic findings (p-values 0.982–0.988). Grouped calcifications had a mean size/extent of 2.1 cm (SD 0.6) in the low-energy contrast images, and a mean size/extent of 2.2 cm (SD 0.6) in the standard digital mammogram images. Masses had a mean size of 1.8 cm (SD 0.2) in both groups. Calcifications were equally visible on both CEDM and FFDM. Conclusion: Low energy CEDM images are equivalent to standard FFDM despite the presence of intravenous iodinated contrast. Low energy CEDM images may be used for interpretation in place of the FFDM, thereby reducing patient dose.

  7. Low energy mammogram obtained in contrast-enhanced digital mammography (CEDM) is comparable to routine full-field digital mammography (FFDM)

    International Nuclear Information System (INIS)

    Francescone, Mark A.; Jochelson, Maxine S.; Dershaw, D. David; Sung, Janice S.; Hughes, Mary C.; Zheng, Junting; Moskowitz, Chaya; Morris, Elizabeth A.

    2014-01-01

    Purpose: Contrast enhanced digital mammography (CEDM) uses low energy and high energy exposures to produce a subtracted contrast image. It is currently performed with a standard full-field digital mammogram (FFDM). The purpose is to determine if the low energy image performed after intravenous iodine injection can replace the standard FFDM. Methods: And Materials: In an IRB approved HIPAA compatible study, low-energy CEDM images of 170 breasts in 88 women (ages 26–75; mean 50.3) undergoing evaluation for elevated risk or newly diagnosed breast cancer were compared to standard digital mammograms performed within 6 months. Technical parameters including posterior nipple line (PNL) distance, compression thickness, and compression force on the MLO projection were compared. Mammographic findings were compared qualitatively and quantitatively. Mixed linear regression using generalized estimating equation (GEE) method was performed. Intraclass correlation coefficients (ICC) with 95% confidence interval (95%CI) were estimated to assess agreement. Results: No statistical difference was found in the technical parameters compression thickness, PNL distance, compression force (p-values: 0.767, 0.947, 0.089). No difference was found in the measured size of mammographic findings (p-values 0.982–0.988). Grouped calcifications had a mean size/extent of 2.1 cm (SD 0.6) in the low-energy contrast images, and a mean size/extent of 2.2 cm (SD 0.6) in the standard digital mammogram images. Masses had a mean size of 1.8 cm (SD 0.2) in both groups. Calcifications were equally visible on both CEDM and FFDM. Conclusion: Low energy CEDM images are equivalent to standard FFDM despite the presence of intravenous iodinated contrast. Low energy CEDM images may be used for interpretation in place of the FFDM, thereby reducing patient dose

  8. Comparative evaluation of average glandular dose and image of digital mammography and film mammography in Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Nogueira, M.; Leyton, F.; Rodrigue, L. L.C.; Oliveira, M.A.; Joana, G.S.; Silva, S.D.

    2015-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The purpose of our study was to compare the technical performance of digital mammographic and screen-film mammography. A PMMA phantom with objects to simulate breast structures. For the screen/film (SF) technique the results showed that 54% mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 67% services showed inadequate performance in their processing systems, which had significant influence on the image quality. At the mean glandular dose only 44% of digital systems evaluated were compliant in all thicknesses of PMMA. The average glandular dose AGD was 90 % higher than in screen/film systems. (authors)

  9. Invasive ductal carcinoma vs. invasive lobular carcinoma; mammographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chun; Do, Young Soo; Oh, Hoon Il; Han, Yoon Hee; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1996-01-01

    The purpose of this study is to evaluate mammographic findings of invasive ductal carcinoma (IDC) and invasive lobular carcinoma(ILC) and to find differential points between the two. 239 patients, who underwent mammography prior to surgery and were proved to have IDC(patients) or ILC(15 patients) pathologically, were analized retrospectively. On mammogram, presence of mass and microcalcification were analized. When there was a mass on mammogram, lesion opacity was classified into high, equal, or low opacity and border of the mass was classified into spiculated, poorly marginated, and well-marginated. When there was no definite mass, mammographic findings were classifie into asymmetric opacity and no mass. Masses were observed in 168 patients(75%) of IDC and 12 patients(80%) of ILC. Border of the masses were spiculated(n=50, 22.3%), poorly marginated(n=112, 50%), or well-marginated(n=6, 2.7%) in patients with IDC. Spiculated and poorly marginated borders were observed in 8 patients(53.3%) and 4 patients(26.7%) respectively, in patients with ILC. Microcalcifications were seen in 88 patients(17.3%) of IDC and patients(33.3%) of ILC. Although equal or low opacities were observed more frequently in ILC and microcalcifications were noted more frequently in IDC, it was difficult to differentiate the two diseases based on mammographic findings.

  10. Invasive ductal carcinoma vs. invasive lobular carcinoma; mammographic findings

    International Nuclear Information System (INIS)

    Lee, Eun Chun; Do, Young Soo; Oh, Hoon Il; Han, Yoon Hee; Kim, Ki Soo; Chin, Soo Yil

    1996-01-01

    The purpose of this study is to evaluate mammographic findings of invasive ductal carcinoma (IDC) and invasive lobular carcinoma(ILC) and to find differential points between the two. 239 patients, who underwent mammography prior to surgery and were proved to have IDC(patients) or ILC(15 patients) pathologically, were analized retrospectively. On mammogram, presence of mass and microcalcification were analized. When there was a mass on mammogram, lesion opacity was classified into high, equal, or low opacity and border of the mass was classified into spiculated, poorly marginated, and well-marginated. When there was no definite mass, mammographic findings were classifie into asymmetric opacity and no mass. Masses were observed in 168 patients(75%) of IDC and 12 patients(80%) of ILC. Border of the masses were spiculated(n=50, 22.3%), poorly marginated(n=112, 50%), or well-marginated(n=6, 2.7%) in patients with IDC. Spiculated and poorly marginated borders were observed in 8 patients(53.3%) and 4 patients(26.7%) respectively, in patients with ILC. Microcalcifications were seen in 88 patients(17.3%) of IDC and patients(33.3%) of ILC. Although equal or low opacities were observed more frequently in ILC and microcalcifications were noted more frequently in IDC, it was difficult to differentiate the two diseases based on mammographic findings

  11. Size, node status and grade of breast tumours: association with mammographic parenchymal patterns

    Energy Technology Data Exchange (ETDEWEB)

    Sala, E.; Solomon, L.; McCann, J. [Department of Community Medicine, Strangeways Research Laboratory, Worts Causeway, Cambridge (United Kingdom); Warren, R. [Cambridge and Huntingdon Breast Screening Service, Rosie Maternity Hospital, Robinson Way, Cambridge (United Kingdom); Duffy, S. [MRC-Biostatistics Unit, Institute of Public Health, Cambridge (United Kingdom); Luben, R. [Department of Clinical Gerontology, Strangeways Research Laboratory, Cambridge (United Kingdom); Day, N. [Department of Community Medicine, Institute of Public Health, Robinson Way, Cambridge, CB2 2SR (United Kingdom)

    2000-01-01

    A case-control study was designed to assess the association of mammographic parenchymal patterns with the risk of in-situ and invasive breast cancer. In addition, the relationship between tumour characteristics and mammographic patterns were also investigated. A total of 875 patients with breast cancer were selected and matched with 2601 controls. Mammographic parenchymal patterns of breast tissue were assessed according to Wolfe's classification, and statistical analysis was by conditional logistic regression. Relative to the N1 pattern, the odds ratios of having an invasive breast cancer associated with the P2 and DY patterns were 1.8 and 1.4, respectively. In addition, the odd ratios of having an invasive grade 3 breast cancer associated with the P2 and DY patterns were 2.8 and 3.9, respectively. Relative to the combined N1/P1 pattern, the odd ratios of having a breast cancer smaller than 14 mm, 15-29 mm, or larger than 30 mm associated with the combined high-risk P2/DY pattern (P2 + DY) were 1.2, 1.6, and 2.0, respectively. Finally, women with the P2/DY pattern were twice as likely to have a breast cancer which had already spread to the axillary nodes, compared to women with women with the N1/P1 pattern (odds ratios of 2.1 and 1.4, respectively). Our results confirm previous findings suggesting that mammographic parenchymal patterns may serve as indicators of risk for breast cancer. Our results also suggest that mammographic parenchymal patterns are associated with the stage at which breast cancer is detected. (orig.)

  12. Size, node status and grade of breast tumours: association with mammographic parenchymal patterns

    International Nuclear Information System (INIS)

    Sala, E.; Solomon, L.; McCann, J.; Warren, R.; Duffy, S.; Luben, R.; Day, N.

    2000-01-01

    A case-control study was designed to assess the association of mammographic parenchymal patterns with the risk of in-situ and invasive breast cancer. In addition, the relationship between tumour characteristics and mammographic patterns were also investigated. A total of 875 patients with breast cancer were selected and matched with 2601 controls. Mammographic parenchymal patterns of breast tissue were assessed according to Wolfe's classification, and statistical analysis was by conditional logistic regression. Relative to the N1 pattern, the odds ratios of having an invasive breast cancer associated with the P2 and DY patterns were 1.8 and 1.4, respectively. In addition, the odd ratios of having an invasive grade 3 breast cancer associated with the P2 and DY patterns were 2.8 and 3.9, respectively. Relative to the combined N1/P1 pattern, the odd ratios of having a breast cancer smaller than 14 mm, 15-29 mm, or larger than 30 mm associated with the combined high-risk P2/DY pattern (P2 + DY) were 1.2, 1.6, and 2.0, respectively. Finally, women with the P2/DY pattern were twice as likely to have a breast cancer which had already spread to the axillary nodes, compared to women with women with the N1/P1 pattern (odds ratios of 2.1 and 1.4, respectively). Our results confirm previous findings suggesting that mammographic parenchymal patterns may serve as indicators of risk for breast cancer. Our results also suggest that mammographic parenchymal patterns are associated with the stage at which breast cancer is detected. (orig.)

  13. Mammographic changes in postmenopausal women : comparative effects between continuous combined hormone and single estrogen replacement therapy

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Sug; Choi, Jong Tae; Jung, Kyoon Soon; Jung, Seung Hye [Jeil Women' s Hospital, Seoul (Korea, Republic of)

    1997-06-01

    As the use of hormone replacement therapy for the menopausal women increases, some caution is advised, since there is an increased risk of breast cancer. Accordingly, the importance of regular mammography has been addressed. This cross-setional study analyzed the effects of different hormone therapies on mammographic density. Sixty-seven postemenopausal women who had completed one year of hormone therapy and had undergone follow-up mammography, were divided into two groups : Group I : continuous conjugated equine estrogen, 0.625mg, plus continuous medroxyprogesterone acetate, 2.5mg (n=48), Group II : continuous conjugated equine estrogen 0.625mg (n=19). The mammograms were read by two radiologists. With regard to the radiologists involved, interobserver reliabillity (kappa) was 0.70 and intraobserver reliability (kappa) was 0.51 and 0.67. Before hormone therapy, factors related to decreased mammographic density were age and number of full term pregnancies (p<0.05). After one year of hormone therapy, body fat showed a significant increase (p<0.05), but in spite of this, increased mammographic density induced by hormone therapy remained significantly high (p<0.05). Compared with Group II, Group I showed a significant increase in mammographic density (p<0.05). In Group I, mammographic density increased from P2 to DY pattern in two cases, but there was no such change in Group II. The increase of mammographic density seen in Group II was much more significant statistically than that seen in Group I. The mammograms of women who have undergone continuous combined hormone therapy should therefore be interpreted very cautiously.

  14. Mammographic changes in postmenopausal women : comparative effects between continuous combined hormone and single estrogen replacement therapy

    International Nuclear Information System (INIS)

    Oh, Sug; Choi, Jong Tae; Jung, Kyoon Soon; Jung, Seung Hye

    1997-01-01

    As the use of hormone replacement therapy for the menopausal women increases, some caution is advised, since there is an increased risk of breast cancer. Accordingly, the importance of regular mammography has been addressed. This cross-setional study analyzed the effects of different hormone therapies on mammographic density. Sixty-seven postemenopausal women who had completed one year of hormone therapy and had undergone follow-up mammography, were divided into two groups : Group I : continuous conjugated equine estrogen, 0.625mg, plus continuous medroxyprogesterone acetate, 2.5mg (n=48), Group II : continuous conjugated equine estrogen 0.625mg (n=19). The mammograms were read by two radiologists. With regard to the radiologists involved, interobserver reliabillity (kappa) was 0.70 and intraobserver reliability (kappa) was 0.51 and 0.67. Before hormone therapy, factors related to decreased mammographic density were age and number of full term pregnancies (p<0.05). After one year of hormone therapy, body fat showed a significant increase (p<0.05), but in spite of this, increased mammographic density induced by hormone therapy remained significantly high (p<0.05). Compared with Group II, Group I showed a significant increase in mammographic density (p<0.05). In Group I, mammographic density increased from P2 to DY pattern in two cases, but there was no such change in Group II. The increase of mammographic density seen in Group II was much more significant statistically than that seen in Group I. The mammograms of women who have undergone continuous combined hormone therapy should therefore be interpreted very cautiously

  15. Calcified trichinosis of pectoral muscle: mammographic appearance

    Energy Technology Data Exchange (ETDEWEB)

    Apesteguia, L. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Murillo, A. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Biurrun, J. [Servicio de Radiologia, Hospital Virgen del Camino, Pamplona (Spain); Garcia-Rostan, G. [Servicio Anatomia Patologica, Hospital Virgen del Camino, Pamplona (Spain); Reta, A. [Servicio de Analisis Clinicos, Hospital Virgen del Camino, Pamplona (Spain); Dominguez, F. [Servicio Cirugia, Hospital Virgen del Camino, Pamplona (Spain)

    1995-12-31

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients` diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  16. Calcified trichinosis of pectoral muscle: mammographic appearance

    International Nuclear Information System (INIS)

    Apesteguia, L.; Murillo, A.; Biurrun, J.; Garcia-Rostan, G.; Reta, A.; Dominguez, F.

    1995-01-01

    By mammographic screening we had detected six asymptomatic women who showed numerious tiny and well-delineated round to ovoid microcalcification superimposed on pectoral shadows, in the oblique medio-lateral (OML) view. Our objective was to achieve a better evaluation of these calcifications and investigate their origin. Magnified mammograms of pectoral muscles were done in the six women. A questionnaire concerning the patients' diets was also administered. Trichinella antibody titres were quantified by sero-agglutination. Microcalcifications within pectoral muscle fibres were demonstrated in all the cases. Five women admitted to having eaten home-made pork products in the past. One of them showed a slightly elevated antibody titre. We confirmed the suspected diagnosis of calcified trichinosis by a surgical biopsy of the pectoral muscle performed on one of the patients. We conclude that chronic calcified trichinosis of the pectoral muscle can be visualised in the OML view of a conventional mammogram. The mammographic appearance of this entity is very characteristic and biopsy would not be required for its diagnosis in the future. (orig.)

  17. Contour tracing for segmentation of mammographic masses

    International Nuclear Information System (INIS)

    Elter, Matthias; Held, Christian; Wittenberg, Thomas

    2010-01-01

    CADx systems have the potential to support radiologists in the difficult task of discriminating benign and malignant mammographic lesions. The segmentation of mammographic masses from the background tissue is an important module of CADx systems designed for the characterization of mass lesions. In this work, a novel approach to this task is presented. The segmentation is performed by automatically tracing the mass' contour in-between manually provided landmark points defined on the mass' margin. The performance of the proposed approach is compared to the performance of implementations of three state-of-the-art approaches based on region growing and dynamic programming. For an unbiased comparison of the different segmentation approaches, optimal parameters are selected for each approach by means of tenfold cross-validation and a genetic algorithm. Furthermore, segmentation performance is evaluated on a dataset of ROI and ground-truth pairs. The proposed method outperforms the three state-of-the-art methods. The benchmark dataset will be made available with publication of this paper and will be the first publicly available benchmark dataset for mass segmentation.

  18. Mammographic and sonographic features of fat necrosis of the breast

    International Nuclear Information System (INIS)

    Upadhyaya, Vidya S; Uppoor, Raghuraj; Shetty, Lathika

    2013-01-01

    Imaging features of fat necrosis vary depending on its stage of evolution and can mimic malignancy in late stages. Imaging may suffice to differentiate fat necrosis in the early stages from malignancy and thus avoid unnecessary biopsy. In this pictorial essay, we present combination of benign features in mammography and/or ultrasonography (USG) that can lead to imaging diagnosis of fat necrosis. The follow-up imaging features of fat necrosis which mirror its pathophysiological evolution have also been demonstrated. To summarize, in the appropriate clinical setting, no mammographic features suspicious for malignancy should be present. When the typical mammographic features are not present, USG can aid with the diagnosis and follow up USG can confirm it

  19. Comparative study of dose estimation in the change a conventional mammography to digital mammography

    International Nuclear Information System (INIS)

    Vazquez Vazquez, R.; Otero Martinez, C.; Soto Bua, M.; Santamarina Vazquez, F.; Carril Iglesias, S.; Lobato Busto, R.; Luna Vega, V.; Mosquera Sueiro, J.; Sqanchez Garcia, M.; Pombar Camean, M.

    2011-01-01

    Mammographic studies are now one of the most demanding radiological because of its effectiveness in detecting breast cancer early. The introduction of digital mammography has been a major advance because it has overcome some of the limitations of conventional systems. Due to the nature of the radiosensitive glandular tissue becomes very important control of the dose given to patients. In the present study is to analyze the variations in dosimetry that can exist between a conventional mammography and digital mammography.

  20. Mammographic profiles of women with symptomatic breast diseases ...

    African Journals Online (AJOL)

    Methods: This was a prospective descriptive analytical study of women with symptomatic breast diseases who had mammography between January 2012 and December 2016 at our health facilities. Data sheet was developed to record the patients' biodata, indication for referral, and mammographic findings. Results: During ...

  1. The instrument control unit of SPICA SAFARI: a macro-unit to host all the digital control functionalities of the spectrometer

    Science.gov (United States)

    Di Giorgio, Anna Maria; Biondi, David; Saggin, Bortolino; Shatalina, Irina; Viterbini, Maurizio; Giusi, Giovanni; Liu, Scige J.; Cerulli-Irelli, Paquale; Van Loon, Dennis; Cara, Christophe

    2012-09-01

    We present the preliminary design of the Instrument Control Unit (ICU) of the SpicA FAR infrared Instrument (SAFARI), an imaging Fourier Transform Spectrometer (FTS) designed to give continuous wavelength coverage in both photometric and spectroscopic modes from around 34 to 210 µm. Due to the stringent requirements in terms of mass and volume, the overall SAFARI warm electronics will be composed by only two main units: Detector Control Unit and ICU. ICU is therefore a macro-unit incorporating the four digital sub-units dedicated to the control of the overall instrument functionalities: the Cooler Control Unit, the Mechanism Control Unit, the Digital processing Unit and the Power Supply Unit. Both the mechanical solution adopted to host the four sub-units and the internal electrical architecture are presented as well as the adopted redundancy approach.

  2. Mammographic and sonographic spectrum of non-puerperal mastitis

    NARCIS (Netherlands)

    M.H. Lequin (Maarten); J. van Spengler (J.); R. van Pel; C.H.J. van Eijck (Casper); H. van Overhagen (H.)

    1995-01-01

    textabstractThe goal of this study was to explore possible specific mammographic and sonographic features in women with non-puerperal mastitis (NPM), in order to make an accurate diagnosis and prevent unnecessary surgical procedures. From a group of 93 patients with NPM diagnosed between 1987 and

  3. Identification of two novel mammographic density loci at 6Q25.1.

    Science.gov (United States)

    Brand, Judith S; Li, Jingmei; Humphreys, Keith; Karlsson, Robert; Eriksson, Mikael; Ivansson, Emma; Hall, Per; Czene, Kamila

    2015-06-03

    Mammographic density (MD) is a strong heritable and intermediate phenotype for breast cancer, but much of its genetic variation remains unexplained. We performed a large-scale genetic association study including 8,419 women of European ancestry to identify MD loci. Participants of three Swedish studies were genotyped on a custom Illumina iSelect genotyping array and percent and absolute mammographic density were ascertained using semiautomated and fully automated methods from film and digital mammograms. Linear regression analysis was used to test for SNP-MD associations, adjusting for age, body mass index, menopausal status and six principal components. Meta-analyses were performed by combining P values taking sample size, study-specific inflation factor and direction of effect into account. Genome-wide significant associations were observed for two previously identified loci: ZNF365 (rs10995194, P = 2.3 × 10(-8) for percent MD and P = 8.7 × 10(-9) for absolute MD) and AREG (rs10034692, P = 6.7 × 10(-9) for absolute MD). In addition, we found evidence of association for two variants at 6q25.1, both of which are known breast cancer susceptibility loci: rs9485370 in the TAB2 gene (P = 4.8 × 10(-9) for percent MD and P = 2.5 × 10(-8) for absolute MD) and rs60705924 in the CCDC170/ESR1 region (P = 2.2 × 10(-8) for absolute MD). Both regions have been implicated in estrogen receptor signaling with TAB2 being a potential regulator of tamoxifen response. We identified two novel MD loci at 6q25.1. These findings underscore the importance of 6q25.1 as a susceptibility region and provide more insight into the mechanisms through which MD influences breast cancer risk.

  4. Ultrasonographic and mammographic findings of gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Soo Kyung; Choi, Gyo Chang; Hong, Hyun Sook; Kim, Young Beom; Lee, Hae Kyung; Kwon, Kui Hyang [Soonchunhyang Univ. College of Medicine, Asan (Korea, Republic of)

    1996-11-01

    The purpose of this study is to evaluate the radiologic features and clinical utility of ultrasonography and mammography in cases of gynecomastia. This study involved 40 men in whom gynecomastia had been pathologically diagnosed by surgical incision. In 21 cases, a retrospective analysis of ultrasonographic and mammographic findings was performed. Causative factors of gynecomastia among the 40 pathologically-proven cases were idiopathic or pubertal in 33 cases, related to male hormone deficiency in three cases and to chronic liver disease in four. Bi-lateral involvement was seen in 14 cases, and unilateral involvement in 26;among unilateral cases, right side was involved in 10 cases, and the left side in 16. Mammographically, a subareolar discoid lesion was present in 12 cases, diffuse increased breast density was seen in five cases and dendritic marginated subareolar lesion without microcalcification in one. Ultrasonographically, a round smooth marginated low echogenic lesion in the subareolar region was seen in five cases, a diffuse hyperechogenic pattern without definite mass in two cases and an ill defined low echogenic lesion in one. The male breast is small, so in cases of gynecomastia, ultrasonography is an effective diagnostic modality. Mamography will, however, be helpful in the detection of microcalcification in cases of gynecomastia seen on sonography.

  5. Mammographic feature enhancement by multiscale analysis

    International Nuclear Information System (INIS)

    Laine, A.F.; Schuler, S.; Fan, J.; Huda, W.

    1994-01-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis by overcomplete multiresolution representations. The authors show that efficient representations may be identified within a continuum of scale-space and used to enhance features of importance to mammography. Methods of contrast enhancement are described based on three overcomplete multiscale representations: (1) the dyadic wavelet transform (separable), (2) the var-phi-transform (nonseparable, nonorthogonal), and (3) the hexagonal wavelet transform (nonseparable). Multiscale edges identified within distinct levels of transform space provide local support for image enhancement. Mammograms are reconstructed from wavelet coefficients modified at one or more levels by local and global nonlinear operators. In each case, edges and gain parameters are identified adaptively by a measure of energy within each level of scale-space. The authors show quantitatively that transform coefficients, modified by adaptive nonlinear operators, can make more obvious unseen or barely seen features of mammography without requiring additional radiation. The results are compared with traditional image enhancement techniques by measuring the local contrast of known mammographic features. The authors demonstrate that features extracted from multiresolution representations can provide an adaptive mechanism for accomplishing local contrast enhancement. By improving the visualization of breast pathology, they can improve chances of early detection while requiring less time to evaluate mammograms for most patients

  6. Mammographic density measurements are not affected by mammography system.

    Science.gov (United States)

    Damases, Christine N; Brennan, Patrick C; McEntee, Mark F

    2015-01-01

    Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman's density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists' visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer's equipment affects a woman's MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation ([Formula: see text]; [Formula: see text]), while the VDG ([Formula: see text]; [Formula: see text]) and AvBD% ([Formula: see text]; [Formula: see text]) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS ([Formula: see text]; [Formula: see text]), however, the systems demonstrated an almost perfect agreement for VDG ([Formula: see text]; [Formula: see text]).

  7. Investigation of support vector machine for the detection of architectural distortion in mammographic images

    International Nuclear Information System (INIS)

    Guo, Q; Shao, J; Ruiz, V

    2005-01-01

    This paper investigates detection of architectural distortion in mammographic images using support vector machine. Hausdorff dimension is used to characterise the texture feature of mammographic images. Support vector machine, a learning machine based on statistical learning theory, is trained through supervised learning to detect architectural distortion. Compared to the Radial Basis Function neural networks, SVM produced more accurate classification results in distinguishing architectural distortion abnormality from normal breast parenchyma

  8. Investigation of support vector machine for the detection of architectural distortion in mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Q [Department of Cybernetics, University of Reading, Reading RG6 6AY (United Kingdom); Shao, J [Department of Electronics, University of Kent at Canterbury, Kent CT2 7NT (United Kingdom); Ruiz, V [Department of Cybernetics, University of Reading, Reading RG6 6AY (United Kingdom)

    2005-01-01

    This paper investigates detection of architectural distortion in mammographic images using support vector machine. Hausdorff dimension is used to characterise the texture feature of mammographic images. Support vector machine, a learning machine based on statistical learning theory, is trained through supervised learning to detect architectural distortion. Compared to the Radial Basis Function neural networks, SVM produced more accurate classification results in distinguishing architectural distortion abnormality from normal breast parenchyma.

  9. Body mass index and participation in organized mammographic screening

    DEFF Research Database (Denmark)

    Hellmann, Sophie Sell; Njor, Sisse Helle; Lynge, Elsebeth

    2015-01-01

    BACKGROUND: Breast cancer is the leading cancer among women, and early diagnosis is essential for future prognosis. Evidence from mainly cross-sectional US studies with self-reported exposure and outcome found positive association of body mass index (BMI) with non-participation in mammographic...... with normal weight. This association was limited to postmenopausal women (Wald test p = 0.08), with enhanced non-participation in underweight (2.83: 1.52-5.27) and obese women of class II and III (1.84: 1.15-2.95; 2.47: 1.20-5.06) as compared to normal weight postmenopausal women. There was no effect...... modification by HT, previous screening participation, or morbidities, besides suggestive evidence of enhanced non-participation in diabetic overweight and obese women. CONCLUSIONS: Underweight and very obese postmenopausal women were significantly less likely to participate in mammographic screening than women...

  10. Mammographic classification of breast lesions amongst women in ...

    African Journals Online (AJOL)

    Objectives: The study was to classify lesions identified on mammograms using Breast Imaging Reporting and Data System (BIRADS) grading method. This was in view of ascertaining the rate of occurrence of breast malignancy of the studied population. Methods: A retrospective cohort study of 416 mammographic reports of ...

  11. The implementation of an AR (augmented reality) approach to support mammographic interpretation training: an initial feasibility study

    Science.gov (United States)

    Tang, Qiang; Chen, Yan; Gale, Alastair G.

    2017-03-01

    Appropriate feedback plays an important role in optimising mammographic interpretation training whilst also ensuring good interpretation performance. The traditional keyboard, mouse and workstation technical approach has a critical limitation in providing supplementary image-related information and providing complex feedback in real time. Augmented Reality (AR) provides a possible superior approach in this situation, as feedback can be provided directly overlaying the displayed mammographic images so making a generic approach which can also be vendor neutral. In this study, radiological feedback was dynamically remapped virtually into the real world, using perspective transformation, in order to provide a richer user experience in mammographic interpretation training. This is an initial attempt of an AR approach to dynamically superimpose pre-defined feedback information of a DICOM image on top of a radiologist's view, whilst the radiologist is examining images on a clinical workstation. The study demonstrates the feasibility of the approach, although there are limitations on interactive operations which are due to the hardware used. The results of this fully functional approach provide appropriate feedback/image correspondence in a simulated mammographic interpretation environment. Thus, it is argued that employing AR is a feasible way to provide rich feedback in the delivery of mammographic interpretation training.

  12. Novel Associations between Common Breast Cancer Susceptibility Variants and Risk-Predicting Mammographic Density Measures

    OpenAIRE

    Stone, Jennifer; Thompson, Deborah J.; dos-Santos-Silva, Isabel; Scott, Christopher; Tamimi, Rulla M.; Lindstrom, Sara; Kraft, Peter; Hazra, Aditi; Li, Jingmei; Eriksson, Louise; Czene, Kamila; Hall, Per; Jensen, Matt; Cunningham, Julie; Olson, Janet E.

    2015-01-01

    Mammographic density measures adjusted for age and body mass index (BMI) are heritable predictors of breast cancer risk but few mammographic density-associated genetic variants have been identified. Using data for 10,727 women from two international consortia, we estimated associations between 77 common breast cancer susceptibility variants and absolute dense area, percent dense area and absolute non-dense area adjusted for study, age and BMI using mixed linear modeling. We found strong suppo...

  13. 11-gauge vacuum assisted directional biopsy of breast calcifications, using upright stereotactic guidance

    International Nuclear Information System (INIS)

    Nisbet, A.P.; Borthwick-Clarke, A.; Scott, N.

    2000-01-01

    To assess the use of a prototype vacuum assisted biopsy device on a standard upright mammography unit, using a slightly modified digital stereotactic add-on component. A group comprised of 42 sequential patients, who had been recalled from an asymptomatic mammographic screening programme, were studied. All 42 were recalled for assessment of small clusters of microcalcification, graded as indeterminate. Group 1 (21 patients) were biopsied using 14-gauge automated large core needle biopsy. Group 2 (21 patients) were biopsied using 11-gauge vacuum assisted biopsy. Both groups had mammographic guidance on the same upright mammographic unit (Siemens 3000), with Opdima Digital Stereotactic add-on. A total of 86% of specimen radiographs in Group 2 patients (vacuum assisted biopsy) showed successful sampling of the calcifications, compared to 62% of Group 1 patients (14-gauge automated large core biopsies). This study shows that vacuum assisted biopsy is possible using upright stereotactic mammography units. The technique shows promise as a biopsy tool, offering larger cores compared to 14-gauge automated large core biopsy, while requiring less space and lower purchase price compared to dedicated prone biopsy tables. The technique also offers access to biopsy in patients with posterior lesions and for patients who cannot tolerate prone positioning

  14. Mammographic follow-up after conservation therapy for breast cancer

    International Nuclear Information System (INIS)

    Gu Yajia; Xiao Qin; Zheng Xiaojing; Wu Jiong; Chen Jiayi; Gu Rongfeng; Feng Xiaoyuan

    2006-01-01

    Objective: To recognize the mammographic changes after conservation therapy for breast carcinoma. Methods: A total of 139 follow-up mammographic examinations in 85 cases were studied during the period between 1999 and 2004. Mammography was performed at intervals of 6 months for the first 2 years, then annually. Attention was paid to mammographic change patterns of conservation therapy for breast carcinoma, including breast edema, skin thickening, architectural disturbance, asymmetric density, architectural distortion retraction, and calcifications. SPSS version 11.0 for windows was used to perform all statistical tests. Kruskal-Wallis H test was used for calculating the overall statistical differences between difference periods. Categorical data were expressed as percentages and analyzed by using the X 2 test. The age of the patients ranged from 25 to 63 years (mediate, 44 years old). The time of follow-up observation ranged from 1 week to 72 months. Results: Two cases were normal on mammograms. High proportion of abnormal mammography was seen in the period of 12 month (40.3%, 56/139) and 24 month (21.6%, 30/139), respectively. Various findings appeared in various periods and the difference was statistically significant(X 2 =30.998, v=6, P=0.001). Mild edema appeared in the first 3 years. Moderately severe or marked breast edema may be present between 6 months to 12 months, then slowly resolved. The appearance and disappearance of skin thickening were similar to the process of breast edema. The changes of architectural disturbance did not correlate with time (X 2 =8.634, P>0.05), but on sequential mammograms for same patient, the extent of architectural disturbance relieved over time (17/19). Asymmetric density was found in only 5 patients, and disappeared in later period of follow-up in 3. Architectural distortion retraction got more and more obvious with time, and kept stable after certain period of time. Calcifications were shown in 2 patients, including 1

  15. Patients Mammographic Dose Survey in a Sample of Slovak Mammography Departments

    International Nuclear Information System (INIS)

    Nikodemova, D.; Horvathova, M.; Gbelcova, L.

    2008-01-01

    Breast cancer is the most frequent cancer and the most frequent cause of cancer induced deaths in Europe. Demographic trends indicate a continuing increase in this substantial public health problem. Systematic early detection, effective diagnostic pathways and high quality services have the ability for lowering the breast cancer mortality rates and for reducing the burden of this disease in the population The widespread use of mammography for early breast cancer detection is highly accepted all over the world. For achievement of a successful national mammography programme in Slovakia, a national QA/QC mammography system was introduced. Coming from alarming values of increase of malignant neoplasm of breast in Slovakia a national mammography audit has been initiated, performed in three runs and working in three phases: assessment of existing status of practice and equipment performance, as well as education and training of radiologists and radiographers of 42 mammography departments; implementation of technical quality programme and patient dose evaluation; clinical image evaluation. Preventive mammography in spite of being a reasonable examination, which represents health benefit for patient, exceed also the health risk. In 1991-1996 mammographic examination created 1.3% from all medical radiodiagnostic expositions made in Slovakia. In 2005 there were realized 241 208 mammographic examinations, 140 798 of them were noticed like preventive examinations. In 2006 the number of all mammographic examinations in Slovakia increased to 271 755 and of them 156 199 were preventive mammographic examinations. In our presentation we tried to establish the average absorbed glandular doses of patients undergoing mammography examinations in 10 selected departments and to compare the obtained results with European diagnostic reference values. The obtained values were used for the proposal of a new national diagnostic reference value for mammography examinations

  16. Volumetric mammographic density: heritability and association with breast cancer susceptibility loci.

    Science.gov (United States)

    Brand, Judith S; Humphreys, Keith; Thompson, Deborah J; Li, Jingmei; Eriksson, Mikael; Hall, Per; Czene, Kamila

    2014-12-01

    Mammographic density is a strong heritable trait, but data on its genetic component are limited to area-based and qualitative measures. We studied the heritability of volumetric mammographic density ascertained by a fully-automated method and the association with breast cancer susceptibility loci. Heritability of volumetric mammographic density was estimated with a variance component model in a sib-pair sample (N pairs = 955) of a Swedish screening based cohort. Associations with 82 established breast cancer loci were assessed in an independent sample of the same cohort (N = 4025 unrelated women) using linear models, adjusting for age, body mass index, and menopausal status. All tests were two-sided, except for heritability analyses where one-sided tests were used. After multivariable adjustment, heritability estimates (standard error) for percent dense volume, absolute dense volume, and absolute nondense volume were 0.63 (0.06) and 0.43 (0.06) and 0.61 (0.06), respectively (all P associated with rs10995190 (ZNF365; P = 9.0 × 10(-6) and 8.9 × 10(-7), respectively) and rs9485372 (TAB2; P = 1.8 × 10(-5) and 1.8 × 10(-3), respectively). We also observed associations of rs9383938 (ESR1) and rs2046210 (ESR1) with the absolute dense volume (P = 2.6 × 10(-4) and 4.6 × 10(-4), respectively), and rs6001930 (MLK1) and rs17356907 (NTN4) with the absolute nondense volume (P = 6.7 × 10(-6) and 8.4 × 10(-5), respectively). Our results support the high heritability of mammographic density, though estimates are weaker for absolute than percent dense volume. We also demonstrate that the shared genetic component with breast cancer is not restricted to dense tissues only. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  17. Virtual unit delay for digital frequency adaptive T/4 delay phase-locked loop system

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    /processor with a fixed sampling rate considering the cost and complexity, where the number of unit delays that have been adopted should be an integer. For instance, in conventional digital control systems, a single-phase T/4 Delay Phase-Locked Loop (PLL) system takes 50 unit delays (i.e., in a 50-Hz system...... Delay PLL system should be done in its implementation. This process will result in performance degradation in the digital control system, as the exactly required number of delays is not realized. Hence, in this paper, a Virtual Unit Delay (VUD) has been proposed to address such challenges to the digital......Digital micro-controllers/processors enable the cost-effective control of grid-connected power converter systems in terms of system monitoring, signal processing (e.g., grid synchronization), control (e.g., grid current and voltage control), etc. Normally, the control is implemented in a micro-controller...

  18. Establishment of quality assessment standard for mammographic equipment: evaluation of phantom and clinical images

    International Nuclear Information System (INIS)

    Lee, Sung Hoon; Choe, Yeon Hyeon; Chung, Soo Young

    2005-01-01

    The purpose of this study was to establish a quality standard for mammographic equipment Korea and to eventually improve mammographic quality in clinics and hospitals throughout Korea by educating technicians and clinic personnel. For the phantom test and on site assessment, we visited 37 sites and examined 43 sets of mammographic equipment. Items that were examined include phantom test, radiation dose measurement, developer assessment, etc. The phantom images were assessed visually and by optical density measurements. For the clinical image assessment, clinical images from 371 sites were examined following the new Korean standard for clinical image evaluation. The items examined include labeling, positioning, contrast, exposure, artifacts, collimation among others. Quality standard of mammographic equipment was satisfied in all equipment on site visits. Average mean glandular dose was 114.9 mRad. All phantom image test scores were over 10 points (average, 10.8 points). However, optical density measurements were below 1.2 in 9 sets of equipment (20.9%). Clinical image evaluation revealed appropriate image quality in 83.5%, while images from non-radiologist clinics were adequate in 74.6% (91/122), which was the lowest score of any group. Images were satisfactory in 59.0% (219/371) based on evaluation by specialists following the new Korean standard for clinical image evaluation. Satisfactory images had a mean score of 81.7 (1 S.D. =8.9) and unsatisfactory images had a mean score of 61.9 (1 S.D = 11). The correlation coefficient between the two observers was 0.93 (ρ < 0.01) in 49 consecutive cases. The results of the phantom tests suggest that optical density measurements should be performed as part of a new quality standard for mammographic equipment. The new clinical evaluation criteria that was used in this study can be implemented with some modifications for future mammography quality control by the Korean government

  19. Mammographic and sonographic findings of breast cancer in women younger than 35 years

    International Nuclear Information System (INIS)

    Shaw de Paredes, E.; Marsteller, L.; Eden, B.

    1989-01-01

    Breast carcinoma is uncommon in women under 35 years of age and may be difficult to detect because clinically palpable masses are usually benign, and mammography may be limited by dense parenchyma. The purpose of this work was to evaluate the mammographic findings in young patients with breast cancer and the efficacy of mammography in identifying these lesions. During an 8-year period, 100 breast cancers were diagnosed mammography and sonography were performed in 678% and 19% of patients, respectively; mammography demonstrated the lesion in 90% of cases. Mammographic and sonographic findings are presented

  20. Overdiagnosis in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Puliti, Donella; Duffy, Stephen W; Miccinesi, Guido

    2012-01-01

    Overdiagnosis, the detection through screening of a breast cancer that would never have been identified in the lifetime of the woman, is an adverse outcome of screening. We aimed to determine an estimate range for overdiagnosis of breast cancer in European mammographic service screening programmes....

  1. Mammographic density in asymptomatic menopausal women: correlation with clinical and sonographic findings

    Directory of Open Access Journals (Sweden)

    Beatriz Regina Alvares

    2012-06-01

    Full Text Available OBJECTIVE: To evaluate mammographic breast density in asymptomatic menopausal women in correlation with clinical and sonographic findings. MATERIALS AND METHODS: Mammograms and clinical and sonographic findings of 238 asymptomatic patients were retrospectively reviewed in the period from February/2022 to June/2006. The following variables were analyzed: mammographic density patterns, sonographic findings, patients' age, parity, body mass index and use of hormone replacement therapy. RESULTS: Age, parity and body mass index showed a negative correlation with breast density pattern, while use of hormone replacement therapy showed a positive correlation. Supplementary breast ultrasonography was performed in 103 (43.2% patients. Alterations which could not be visualized at mammography were found in 34 (33% of them, most frequently in women with breast density patterns 3 and 4. CONCLUSION: The authors concluded that breast density patterns were influenced by age, parity, body mass index and time of hormone replacement therapy. Despite not having found any malignant abnormality in the studied cases, the authors have observed a predominance of benign sonographic abnormalities in women with high breast density patterns and without mammographic abnormalities, proving the relevance of supplementary ultrasonography to identify breast lesions in such patients.

  2. Overview of the breast cancer and mammographic status in Asia and in Japan

    International Nuclear Information System (INIS)

    Endo, Tokiko

    2017-01-01

    Breast cancer is the top cancer in women both in the most Western and Asian countries. The incidence of the breast cancer is lower in Asia than in the western countries, but, is increasing due to increase life expectancy, increase urbanization and adoption of western life styles. Mammography screening is the only method that has proved to be effective and cost-effective. In Japan, the mammographic breast cancer screening was started in 2004, and quality control has been done by the Japan Central Organization on Quality Assurance of Breast Cancer Screening, which is consisted with nine major societies concerning the breast cancer diagnosis and treatment. The Japanese Society of Radiological Technology and the Japan Society of Medical Physics are the members of this organization and play impotent roles in mammographic quality control. The main activities of this organization are the education for radiological technicians and interpreters and the insurance the mammographic facilities meet radiation dose and image quality standard. I'll introduce the state of the breast cancer and the efforts for breast cancer screening in Asian countries and in Japan

  3. Identification of simulated microcalcifications in white noise and mammographic backgrounds

    International Nuclear Information System (INIS)

    Reiser, Ingrid; Nishikawa, Robert M.

    2006-01-01

    This work investigates human performance in discriminating between differently shaped simulated microcalcifications embedded in white noise or mammographic backgrounds. Human performance was determined through two alternative forced-choice (2-AFC) experiments. The signals used were computer-generated simple shapes that were designed such that they had equal signal energy. This assured equal detectability. For experiments involving mammographic backgrounds, signals were blurred to account for the imaging system modulation transfer function (MTF). White noise backgrounds were computer generated; anatomic background patches were extracted from normal mammograms. We compared human performance levels as a function of signal energy in the expected difference template. In the discrimination task, the expected difference template is the difference between the two signals shown. In white noise backgrounds, human performance in the discrimination task was degraded compared to the detection task. In mammographic backgrounds, human performance in the discrimination task exceeded that of the detection task. This indicates that human observers do not follow the optimum decision strategy of correlating the expected signal template with the image. Human observer performance was qualitatively reproduced by non-prewhitening with eye filter (NPWE) model observer calculations, in which spatial uncertainty was explicitly included by shifting the locations of the expected difference templates. The results indicate that human strategy in the discrimination task may be to match individual signal templates with the image individually, rather than to perform template matching between the expected difference template and the image

  4. Training for integrated digital I and C system of Tomari unit 3

    International Nuclear Information System (INIS)

    Tutiya, Akiyoshi; Sanbe, Takayuki; Hayashi, Hiroshi

    2009-01-01

    In Tomari nuclear power station Unit No.3, integrated digital I and C facilities was applied for each control unit including safety protection system overall and which connect them by bus (a network), and perform data communications for the first time as a Japanese PWR power station. For the continuation of safe and stable operation of Tomari nuclear power station Unit No.3 which is our greatest power supply, it is important to perform appropriate maintenance jobs about integrated digital I and C System at the time of normal operation, periodical inspection and trouble outbreak. For the assured accomplishment of these work by maintenance personnel, we clarified goal of necessary knowledge and skills and examined training facilities and curriculums. (author)

  5. Automated effect-specific mammographic pattern measures

    DEFF Research Database (Denmark)

    Raundahl, Jakob; Loog, Marco; Pettersen, Paola

    2008-01-01

    We investigate the possibility to develop methodologies for assessing effect specific structural changes of the breast tissue using a general statistical machine learning framework. We present an approach of obtaining objective mammographic pattern measures quantifying a specific biological effect......, such as hormone replacement therapy (HRT). We compare results using this approach to using standard density measures. We show that the proposed method can quantify both age related effects and effects caused by HRT. Age effects are significantly detected by our method where standard methodologies fail...

  6. Benefit-risk evaluation of mammographic mass screening

    International Nuclear Information System (INIS)

    Sato, Nobuo; Ogura, Toshihiro

    1990-01-01

    This study evaluated the benefit-risk balance of mammography in mass screening by using survival rates from 3000 breast cancer patients at the Japanese Foundation for Cancer Research Institute Hospital. Because the number of participants in mammographic mass screening was small, asymptomatic patients with pathologically proven early breast cancer were categorized as the screenee group. Symptomatic patients were categorized as the patient group. Survival rates were compared in both the screenee and the patient groups. Based on the difference in areas of survival curves between screenees and patients, the ratio of person-year gain (PYG) to person-year lost (PYL) was obtained. The ratio of PYG to PYL was multiplied by the detection rate resulting from a particular screening program to obtain the benefit/risk ratio. The detection rate of nonpalpable breast cancer was 15 times higher in the screenee group than the patient group. Breast cancer was detected in 7 (0.85%) of 824 patients in the screenee group. Even when mammographic mass screening was started at the age of 30, the benefit of mammography was far superior to the risk. The number of participants in mass screening stratified by age may be required for the conclusion of the benefit-risk balance of mammography in mass screening. (N.K.)

  7. American College of Radiology Accreditation Program for mammographic screening sites: Physical evaluation criteria

    International Nuclear Information System (INIS)

    Hendrick, R.E.; Haus, A.G.; Hubbard, L.B.; Lasky, H.J.; McCrohan, J.; McLelland, R.; Rothenberg, L.N.; Tanner, R.L.; Zinninger, M.D.

    1987-01-01

    The American College of Radiology has initiated a program for the accreditation of mammographic screening sites, which includes evaluation by mail of image quality and average glandular breast dose. Image quality is evaluated by use of a specially designed phantom (a modified RMI 152D Mammographic Phantom) containing simulated microcalcifications, fibrils and masses. Average glandular dose to a simulated 4.5-cm-thick (50% glandular, 50% fat) compressed breast is evaluated by thermoluminescent dosimeter measurements of entrance exposure and half value layer. Standards for acceptable image quality and patient doses are presented and preliminary results of the accreditation program are discussed

  8. A New Instrument for the Measurement of the Waveform in X-Ray Units

    International Nuclear Information System (INIS)

    Ramirez-Jimenez, Francisco J.; Martinez-Hernandez, Marco A.

    2004-01-01

    The experience gained in the quality control in X-ray units used in Radiology has demonstrated that the measurement of the waveform of the X-ray beam, measured as the response of a radiation detector is very helpful to decide if the unit fulfills the quality control requirements and also has been useful to define some kind of faults in the unit. Several instruments are available on the market to make this measurement but they need in general a storage or digital oscilloscope to see the waveform. In this work a stand alone new instrument is proposed in which the waveform is seen in a Liquid Crystal Display (LCD). The instrument is based in the X-ray response of a photo diode. The analog response depending on time is converted to digital numbers that are stored sequentially in a memory. The stored information is recovered with a microcontroller and reconstructed in the screen of the LCD. The instrument is able to measure in the mammographic range from 22 kV to 35 kV and in the conventional range from 40 kV to 120 kV in the different settings of current encountered on practical applications, the time range for the measurement of the X-ray shot is from 100 ms to 3 s. The instrument can be useful in quality control practices and in the verification and maintenance of X-ray units

  9. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2000-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  10. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2001-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  11. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    1999-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  12. Demonstration Project on Mammographic Computer-Aided Diagnosis for Breast Cancer Detection

    National Research Council Canada - National Science Library

    Doi, Kunio

    2002-01-01

    ...) in mammographic detection of breast cancer. Our plan is to develop advanced CAD schemes for detection and characterization of clustered microcalcifications and masses by incorporating artificial neural networks and various image processing techniques...

  13. Positive predictive value of abnormal mammographic findings and role of assessment procedures

    International Nuclear Information System (INIS)

    Menna, S.; Marra, V.; Di Virgilio, M.R.; Macchia, G.; Frigerio, A.

    1999-01-01

    To investigate the positive predictive value for cancer of abnormal mammographic findings and the role of assessment, the authors reviewed a series of 962 patients recalled and examined in the first breast screening center of Turin (Italy), out of 18996 women aged 50-59 from 1991 to 1995, within a population-based mammography program. The results of this study confirm the accuracy of mammography in the early detection of breast cancer and the different role of assessment procedures in the various abnormal mammographic findings. The improvement in positive predictive value for screening demonstrates the importance of the learning curve within the screening team. Most of this improvement could be referred to refined diagnostic criteria for calcifications [it

  14. Mucinous (colloid) breast cancer: mammographic and US features with histologic correlation

    International Nuclear Information System (INIS)

    Memis, Aysenur; Ozdemir, Necmettin; Parildar, Mustafa; Ustun, Esin Emin; Erhan, Yildiz

    2000-01-01

    Objective: Mucinous carcinoma of the breast presents with different survival rates in pure and mixed types. The purpose of this study was to correlate the mammographic and ultrasonographic findings of mucinous carcinoma with histologic features in different types and mucin rates. Material and methods: Thirty-four patients (2.3%) had mucinous cancer after retrospective review of the 1439 breast cancers diagnosed between 1990 and 1996. Twenty-seven patients, 19 pure and eight mixed type of mucinous carcinomas of the breast, were included in this study to evaluate the imaging findings. In 22 of these, the microscopic slides were available and re-evaluated to estimate the volume of extracellular mucin. The volume of the extracellular mucin was classified histologically as: (+), less than 50% of mucin; (++), 50-80% of mucin; and (+++), more than 80% of mucin. Mammographic features with emphasis on margin characteristics and sonographic echo pattern of tumors were correlated with histologic findings. Results: Ten cases (53%) of pure mucinous type carcinomas had a circumscribed mass lesion on the mammograms. The well-defined, lobulated margins of the masses were well correlated with pure histologic type (P 2 analysis) Two-thirds of these tumors had high volume extracellular mucin. All mixed type mucinous carcinomas demonstrated poorly defined or spiculated margins with no relation to the mucin rates (P<0.01). The sonographic appearances of the tumors showed correlation with histologic types. Most of the pure type carcinomas (53%) were seen with isoechogenic echo texture relative to that of subcutaneous fat, while all of the mixed type carcinomas were hypoechogenic (P<0.01). Conclusion: The mammographic and sonographic features of mucinous breast carcinoma show differences in pure and mixed types of the tumor. The most common mammographic appearance of pure mucinous carcinomas with high percentages of mucin is a mass lesion having well-defined margins, which is

  15. A Radix-10 Digit-Recurrence Division Unit: Algorithm and Architecture

    DEFF Research Database (Denmark)

    Lang, Tomas; Nannarelli, Alberto

    2007-01-01

    In this work, we present a radix-10 division unit that is based on the digit-recurrence algorithm. The previous decimal division designs do not include recent developments in the theory and practice of this type of algorithm, which were developed for radix-2^k dividers. In addition to the adaptat...... dynamic range of significant) and it has a shorter latency than a radix-10 unit based on the Newton-Raphson approximation....

  16. Computer aided system for segmentation and visualization of microcalcifications in digital mammograms

    International Nuclear Information System (INIS)

    Reljin, B.; Reljin, I.; Milosevic, Z.; Stojic, T.

    2009-01-01

    Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal 'images' are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph. (authors)

  17. Classification of mammographic masses using generalized dynamic fuzzy neural networks

    International Nuclear Information System (INIS)

    Lim, Wei Keat; Er, Meng Joo

    2004-01-01

    In this article, computer-aided classification of mammographic masses using generalized dynamic fuzzy neural networks (GDFNN) is presented. The texture parameters, derived from first-order gradient distribution and gray-level co-occurrence matrices, were computed from the regions of interest. A total of 343 images containing 180 benign masses and 163 malignant masses from the Digital Database for Screening Mammography were analyzed. A fast approach of automatically generating fuzzy rules from training samples was implemented to classify tumors. This work is novel in that it alleviates the problem of requiring a designer to examine all the input-output relationships of a training database in order to obtain the most appropriate structure for the classifier in a conventional computer-aided diagnosis. In this approach, not only the connection weights can be adjusted, but also the structure can be self-adaptive during the learning process. By virtue of the automatic generation of the classifier by the GDFNN learning algorithm, the area under the receiver-operating characteristic curve, A z , attains 0.868±0.020, which corresponds to a true-positive fraction of 95.0% at a false positive fraction of 52.8%. The corresponding accuracy is 70.0%, the positive predictive value is 62.0%, and the negative predictive value is 91.4%

  18. Impact of contra-lateral breast reshaping on mammographic surveillance in women undergoing breast reconstruction following mastectomy for breast cancer.

    Science.gov (United States)

    Nava, Maurizio B; Rocco, Nicola; Catanuto, Giuseppe; Falco, Giuseppe; Capalbo, Emanuela; Marano, Luigi; Bordoni, Daniele; Spano, Andrea; Scaperrotta, Gianfranco

    2015-08-01

    The ultimate goal of breast reconstruction is to achieve symmetry with the contra-lateral breast. Contra-lateral procedures with wide parenchymal rearrangements are suspected to impair mammographic surveillance. This study aims to evaluate the impact on mammographic detection of mastopexies and breast reductions for contralateral adjustment in breast reconstruction. We retrospectively evaluated 105 women affected by uni-lateral breast cancer who underwent mastectomy and immediate two-stage reconstruction between 2002 and 2007. We considered three groups according to the contra-lateral reshaping technique: mastopexy or breast reduction with inferior dermoglandular flap (group 1); mastopexy or breast reduction without inferior dermoglandular flap (group 2); no contra-lateral reshaping (group 3). We assessed qualitative mammographic variations and breast density in the three groups. Statistically significant differences have been found when comparing reshaped groups with non reshaped groups regarding parenchymal distortions, skin thickening and stromal edema, but these differences did not affect cancer surveillance. The surveillance mammography diagnostic accuracy in contra-lateral cancer detection was not significantly different between the three groups (p = 0.56), such as the need for MRI for equivocal findings at mammographic contra-lateral breast (p = 0.77) and the need for core-biopsies to confirm mammographic suspect of contra-lateral breast cancer (p = 0.90). This study confirms previous reports regarding the safety of mastopexies and breast reductions when performed in the setting of contra-lateral breast reshaping after breast reconstruction. Mammographic accuracy, sensitivity and specificity are not affected by the glandular re-arrangement. These results provide a further validation of the safety of current reconstructive paradigms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Red clover-derived isoflavones and mammographic breast density: a double-blind, randomized, placebo-controlled trial [ISRCTN42940165

    International Nuclear Information System (INIS)

    Atkinson, Charlotte; Warren, Ruth ML; Sala, Evis; Dowsett, Mitch; Dunning, Alison M; Healey, Catherine S; Runswick, Shirley; Day, Nicholas E; Bingham, Sheila A

    2004-01-01

    Isoflavones are hypothesized to protect against breast cancer, but it is not clear whether they act as oestrogens or anti-oestrogens in breast tissue. Our aim was to determine the effects of taking a red clover-derived isoflavone supplement daily for 1 year on mammographic breast density. Effects on oestradiol, follicle-stimulating hormone (FSH), luteinizing hormone (LH), lymphocyte tyrosine kinase activity and menopausal symptoms were also assessed. A total of 205 women (age range 49–65 years) with Wolfe P2 or DY mammographic breast patterns were randomly assigned to receive either a red clover-derived isoflavone tablet (26 mg biochanin A, 16 mg formononetin, 1 mg genistein and 0.5 mg daidzein) or placebo. Change in mammographic breast density, serum oestradiol, FSH, LH, menopausal symptoms and lymphocyte tyrosine kinase activity from baseline to 12 months were assessed. A total of 177 women completed the trial. Mammographic breast density decreased in both groups but the difference between the treatment and placebo was not statistically significant. There was a significant interaction between treatment group and oestrogen receptor (ESR1) PvuII polymorphism for the change in estimated percentage breast density (mean ± standard deviation): TT isoflavone 1.4 ± 12.3% and TT placebo -9.6 ± 14.2%; CT isoflavone -5.2 ± 12.0% and CT placebo -2.8 ± 10.3%; and CC isoflavone -3.4 ± 9.7% and CC placebo -1.1 ± 9.5%. There were no statistically significant treatment effects on oestradiol, FSH, or LH (assessed only in postmenopausal women), or on lymphocyte tyrosine kinase activity. Baseline levels of menopausal symptoms were low, and there were no statistically significant treatment effects on frequency of hot flushes or other menopausal symptoms. In contrast to studies showing that conventional hormone replacement therapies increase mammographic breast density, the isoflavone supplement did not increase mammographic breast density in this population of women

  20. Mammographic CAD: Correlation of regions in ipsilateral views – a ...

    African Journals Online (AJOL)

    Background. Radiologists analyse both standard mammographic views of a breast to confirm the presence of abnormalities and reduce false-positives. However, at present, no computer-aided diagnosis system uses ipsilateral mammograms to confirm the presence of suspicious features. Aim. The aim of this study was to ...

  1. Tumor location and detectability in mammographic screening

    International Nuclear Information System (INIS)

    Schmitt, E.L.; Threatt, B.

    1982-01-01

    The adequacy of a film mammogram that does not visualize the retromammary space or ribs has concerned radiologists. The 79 prevalent cancers detected in the 10,000 self-referred woman at the University of Michigan Breast Cancer Detection Demonstration Project were analyzed for number of films required to detect the cancer, relationship of the cancer to the posterior edge of the film, number of occult lesions, tumor size, histologic type, sensitivity of detection method, and number of interval carcinomas. The mammograms were obtained using a dedicated mammographic machine and the upright position, with visualization of the anterior axillary fold on the mediolateral view. The ribs were not imaged. Of the 79 cancers, 76 were detectable on the mammogram. All were visualized on the mediolateral view, while three were not imaged on the craniocaudal view. Twelve percent of the cancers were within 1 cm of the posterior edge of the film. Only six ''interval'' carcinomas were found in the 10,000 patients within the year of the initial examinations; these women had dense P2 or DY mammographic parenchymal patterns. The detected cancers were smaller and had a significantly higher percentage of noninvasive cancers than in a symptomatic clinical population. Thus, properly exposed film mammograms using vigorous breast compression examine the breast adequately without visualizing the ribs

  2. Implementation of a digital feedwater control system at Dresden Nuclear Power Plant, Units 2 and 3: Final report

    International Nuclear Information System (INIS)

    Zapotocky, A.; Popovic, J.R.; Fournier, R.D.

    1988-12-01

    This report describes the Digital Feedwater Control System Implementation at the Dresden 2 or 3 Units of the BWR Nuclear Power Plant owned by the Commonwealth Edison Company. The digital system has been operational in Unit 3 since August 1986, and in Unit 2 since April 1987. The Bailey Control's Network 90 based digital control system replaced the obsolete GE/MAC 5000 analog control system in the reactor feedwater control loop as a ''like-for-like'' replacement. Operational experience from the Digital Feedwater Control installations has been good and the system demonstrated better performance than the old analog systems. 14 refs., 15 figs., 17 tabs

  3. Apple Pay & Digital Wallets in Mexico and the United States: Illusion or Financial Revolution?

    OpenAIRE

    Heredia Salazar, Ricardo

    2017-01-01

    Abstract: Apple Pay and digital wallets have gained popularity since the fall of 2014. Perceiving Apple Pay & digital wallets as a financial revolution at this moment might be a mistake. The following study shows that it is just the evolution of a payment system in Mexico and the United States of America, a system that opened the door to a possible future financial revolution. Current financial regulation in Mexico and the United States of America is not accurately applied; therefore, proper ...

  4. Mammographic density changes following discontinuation of tamoxifen in premenopausal women with oestrogen receptor-positive breast cancer.

    Science.gov (United States)

    Kim, Won Hwa; Cho, Nariya; Kim, Young-Seon; Yi, Ann

    2018-04-06

    To evaluate the changes in mammographic density after tamoxifen discontinuation in premenopausal women with oestrogen receptor-positive breast cancers and the underlying factors METHODS: A total of 213 consecutive premenopausal women with breast cancer who received tamoxifen treatment after curative surgery and underwent three mammograms (baseline, after tamoxifen treatment, after tamoxifen discontinuation) were included. Changes in mammographic density after tamoxifen discontinuation were assessed qualitatively (decrease, no change, or increase) by two readers and measured quantitatively by semi-automated software. The association between % density change and clinicopathological factors was evaluated using univariate and multivariate regression analyses. After tamoxifen discontinuation, a mammographic density increase was observed in 31.9% (68/213, reader 1) to 22.1% (47/213, reader 2) by qualitative assessment, with a mean density increase of 1.8% by quantitative assessment compared to density before tamoxifen discontinuation. In multivariate analysis, younger age (≤ 39 years) and greater % density decline after tamoxifen treatment (≥ 17.0%) were independent factors associated with density change after tamoxifen discontinuation (p density change with a mean density increase of 1.8%, which was associated with younger age and greater density change after tamoxifen treatment. • Increased mammographic density after tamoxifen discontinuation can occur in premenopausal women. • Mean density increase after tamoxifen discontinuation was 1.8%. • Density increase is associated with age and density decrease after tamoxifen.

  5. Acceptance testing in digital systens of mammography. Protocols applicability; Pruebas de aceptacion en equipos digitales de mamografia. Aplicabilidad de protocolos

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez, R.; Espana, M.L.; Garcia Castanon, P.; Gomez Barrado, A.; Rodriguez Martin, G.; Fernandez Bedoya, B.

    2011-07-01

    Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimun radiation dose compatible with an image quality sutiable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographyc systems. This study has been carried out on the results of ltyhe acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation oin our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the authomatic exposure control compensation and the detector noise, were found out to meet or not the limiting value, depending on the selected protocol. From our results we could suggest, that protocols from manufacturers should be adapted to acknowledged documents on acceptance testing in digital mammography. They buyer representative could even specify the protocol to be followed during the acceptance tests. (Author). 25 refs.

  6. Performance evaluation of a digital mammography unit using a contrast-detail phantom

    Science.gov (United States)

    Elizalde-Cabrera, J.; Brandan, M.-E.

    2015-01-01

    The relation between image quality and mean glandular dose (MGD) has been studied for a Senographe 2000D mammographic unit used for research in our laboratory. The magnitudes were evaluated for a clinically relevant range of acrylic thicknesses and radiological techniques. The CDMAM phantom was used to determine the contrast-detail curve. Also, an alternative method based on the analysis of signal-to-noise (SNR) and contrast-to-noise (CNR) ratios from the CDMAM image was proposed and applied. A simple numerical model was utilized to successfully interpret the results. Optimum radiological techniques were determined using the figures-of-merit FOMSNR=SNR2/MGD and FOMCNR=CNR2/MGD. Main results were: the evaluation of the detector response flattening process (it reduces by about one half the spatial non-homogeneities due to the X- ray field), MGD measurements (the values comply with standards), and verification of the automatic exposure control performance (it is sensitive to fluence attenuation, not to contrast). For 4-5 cm phantom thicknesses, the optimum radiological techniques were Rh/Rh 34 kV to optimize SNR, and Rh/Rh 28 kV to optimize CNR.

  7. Controlled exstirpation of clinically occult but mammographically suspicious findings

    Energy Technology Data Exchange (ETDEWEB)

    Grosse-Vorholt, R

    1981-03-01

    Breast-volume, size and mammographical findings near the chest wall have a great influence on the excision for histological examination. The excision should be done as an controled excision by preoperative marking with a mixture of blue colour and contrast-medium followed by an intraoperative radiography of the exstirpated tissue. We reached in 30 cases a sure excision without any postoperative complications.

  8. Prognosis for Mammographically Occult, Early-Stage Breast Cancer Patients Treated With Breast-Conservation Therapy

    International Nuclear Information System (INIS)

    Yang, Tzu-I. J.; Yang Qifeng; Haffty, Bruce G.; Moran, Meena S.

    2010-01-01

    Purpose: To compare mammographically occult (MamOcc) and mammographically positive (MamPos) early-stage breast cancer patients treated with breast-conservation therapy (BCT), to analyze differences between the two cohorts. Methods and Materials: Our two cohorts consisted of 214 MamOcc and 2168 MamPos patients treated with BCT. Chart reviews were conducted to assess mammogram reports and method of detection. All clinical-pathologic and outcome parameters were analyzed to detect differences between the two cohorts. Results: Median follow-up was 7 years. There were no differences in final margins, T stage, nodal status, estrogen/progesterone receptor status, or 'triple-negative' status. Significant differences included younger age at diagnosis (p o histology (p < 0.0001). At 10 years, the differences in overall survival, cause-specific survival, and distant relapse between the two groups did not differ significantly. The MamOcc cohort had more breast relapses (15% vs. 8%; p = 0.0357), but on multivariate analysis this difference was not significant (hazard ratio 1.0, 95% confidence interval 0.993-1.007, p = 0.9296). Breast relapses were mammographically occult in 32% of the MamOcc and 12% of the MamPos cohorts (p = 0.0136). Conclusions: Although our study suggests that there are clinical-pathologic variations for the MamOcc cohort vs. MamPos patients that may ultimately affect management, breast relapse after BCT was not significantly different. Breast recurrences were more often mammographically occult in the MamOcc cohort; consideration should be given to closer follow-up and alternative imaging strategies (ultrasound, breast MRI) for routine posttreatment examination. To our knowledge, this represents the largest series addressing the prognostic significance of MamOcc cancers treated with BCT.

  9. Smoking and high-risk mammographic parenchymal patterns: a case-control study

    International Nuclear Information System (INIS)

    Sala, Evis; Warren, Ruth; McCann, Jenny; Duffy, Stephen; Luben, Robert; Day, Nicholas

    2000-01-01

    Current smoking was strongly and inversely associated with high-risk patterns, after adjustment for concomitant risk factors. Relative to never smokers, current smokers were significantly less likely to have a high-risk pattern. Similar results were obtained when the analysis was confined to postmenopausal women. Past smoking was not related to the mammographic parenchymal patterns. The overall effect in postmenopausal women lost its significance when adjusted for other risk factors for P2/DY patterns that were found to be significant in the present study, although the results are still strongly suggestive. The present data indicate that adjustment for current smoking status is important when evaluating the relationship between mammographic parenchymal pattern and breast cancer risk. They also indicate that smoking is a prominent potential confounder when analyzing effects of other risk factors such as obesity-related variables. It appears that parenchymal patterns may act as an informative biomarker of the effect of cigarette smoking on breast cancer risk. Overall, epidemiological studies [1,2,3,4] have reported no substantial association between cigarette smoking and the risk of breast cancer. Some studies [5,6,7] reported a significant increase of breast cancer risk among smokers. In recent studies that addressed the association between breast cancer and cigarette smoking, however, there was some suggestion of a decreased risk [8,9,10], especially among current smokers, ranging from approximately 10 to 30% [9,10]. Brunet et al [11] reported that smoking might reduce the risk of breast cancer by 44% in carriers of BRCA1 or BRCA2 gene mutations. Wolfe [12] described four different mammographic patterns created by variations in the relative amounts of fat, epithelial and connective tissue in the breast, designated N1, P1, P2 and DY. Women with either P2 or DY pattern are considered at greater risk for breast cancer than those with N1 or P1 pattern [12

  10. Feature extraction from mammographic images using fast marching methods

    International Nuclear Information System (INIS)

    Bottigli, U.; Golosio, B.

    2002-01-01

    Features extraction from medical images represents a fundamental step for shape recognition and diagnostic support. The present work faces the problem of the detection of large features, such as massive lesions and organ contours, from mammographic images. The regions of interest are often characterized by an average grayness intensity that is different from the surrounding. In most cases, however, the desired features cannot be extracted by simple gray level thresholding, because of image noise and non-uniform density of the surrounding tissue. In this work, edge detection is achieved through the fast marching method (Level Set Methods and Fast Marching Methods, Cambridge University Press, Cambridge, 1999), which is based on the theory of interface evolution. Starting from a seed point in the shape of interest, a front is generated which evolves according to an appropriate speed function. Such function is expressed in terms of geometric properties of the evolving interface and of image properties, and should become zero when the front reaches the desired boundary. Some examples of application of such method to mammographic images from the CALMA database (Nucl. Instr. and Meth. A 460 (2001) 107) are presented here and discussed

  11. Exploratory survey of image quality on CR digital mammography imaging systems in Mexico

    International Nuclear Information System (INIS)

    Gaona, E.; Rivera, T.; Arreola, M.; Franco, J.; Molina, N.; Alvarez, B.; Azorín, C.G.; Casian, G.

    2014-01-01

    The purpose of this study was to assess the current status of image quality and dose in computed radiographic digital mammography (CRDM) systems. Studies included CRDM systems of various models and manufacturers which dose and image quality comparisons were performed. Due to the recent rise in the use of digital radiographic systems in Mexico, CRDM systems are rapidly replacing conventional film-screen systems without any regard to quality control or image quality standards. Study was conducted in 65 mammography facilities which use CRDM systems in the Mexico City and surrounding States. The systems were tested as used clinically. This means that the dose and beam qualities were selected using the automatic beam selection and photo-timed features. All systems surveyed generate laser film hardcopies for the radiologist to read on a scope or mammographic high luminance light box. It was found that 51 of CRDM systems presented a variety of image artefacts and non-uniformities arising from inadequate acquisition and processing, as well as from the laser printer itself. Undisciplined alteration of image processing settings by the technologist was found to be a serious prevalent problem in 42 facilities. Only four of them showed an image QC program which is periodically monitored by a medical physicist. The Average Glandular Dose (AGD) in the surveyed systems was estimated to have a mean value of 2.4 mGy. To improve image quality in mammography and make more efficient screening mammographic in early detection of breast cancer is required new legislation. - Highlights: • Radiation dose in CR digital mammography (CRDM) systems was determined. • Image quality related with dose in CR digital mammography (CRDM) systems was analysed. • Image processing artefacts were observed and correlated with dose. • Measured entrance dose by TL phosphors could be good parameter for radiation protection optimization in patient

  12. 78 FR 47011 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...

  13. 77 FR 50722 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Science.gov (United States)

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...

  14. Unsupervised deep learning applied to breast density segmentation and mammographic risk scoring

    DEFF Research Database (Denmark)

    Kallenberg, Michiel Gijsbertus J.; Petersen, Peter Kersten; Nielsen, Mads

    2016-01-01

    Mammographic risk scoring has commonly been automated by extracting a set of handcrafted features from mammograms, and relating the responses directly or indirectly to breast cancer risk. We present a method that learns a feature hierarchy from unlabeled data. When the learned features are used...... as the input to a simple classifier, two different tasks can be addressed: i) breast density segmentation, and ii) scoring of mammographic texture. The proposed model learns features at multiple scales. To control the models capacity a novel sparsity regularizer is introduced that incorporates both lifetime...... and population sparsity. We evaluated our method on three different clinical datasets. Our state-of-the-art results show that the learned breast density scores have a very strong positive relationship with manual ones, and that the learned texture scores are predictive of breast cancer. The model is easy...

  15. Mammographic Features of Local Recurrence after Conservative Surgery and Radiation Therapy: Comparison with that of the Primary Tumor

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, I.; Oktay, A.

    2007-01-01

    Purpose: To compare the mammographic features of recurrent breast cancer with those of the primary tumor and to determine whether certain mammographic features are associated with a higher risk of local recurrence after breast-conserving therapy. Material and Methods: A retrospective review of mammograms of 421 patients who were treated with conservative surgery and radiotherapy revealed 41 recurrent tumors. Mammographic findings, location, and histopathologic characteristics were retrospectively compared between primary and recurrent tumors. Results: Recurrent tumors were similar in mammographic appearance to primary tumors in 27 (66%) cases. Of 27 primary tumors that occurred as masses without calcifications, 19 (70%) recurred as a mass, and of the six isolated calcifications, five (83%) recurred with calcifications. Ten (53%) of the 19 recurrent masses and five (100%) of the five recurrent calcifications had morphologic features that were similar to those of the primary tumor. Ninety-two percent (11/12) of the recurrences containing microcalcifications (isolated or associated with a mass) had microcalcifications in their primary tumor. Of 27 masses that recurred, the morphology of the primary tumor was obscured in 13 (48%), ill defined in 10 (37%), and spiculated in four (15%) of the masses. Seventy-six percent (31/41) of recurrences were within the lumpectomy quadrant. In 25 (61%) cases, the histologic findings from the primary tumor and the recurrence were identical. Conclusion: The majority of recurrent tumors appear to be mammographically similar to primary tumors. Therefore, it is important to review preoperative mammograms during follow-up of these patients. Although the study population is small, it was noted that mass with spiculated contour is associated with a lower risk for local recurrence

  16. Mammographic features and misdiagnosed analysis on 92 cases with breast cancer

    International Nuclear Information System (INIS)

    Liu Mingjuan; Zhang Xiaoling; Guo Yan

    2010-01-01

    Objective: To investigate the atypical X-ray features in breast cancer and improve the accuracy of diagnosis. Methods: Mammographic features of 92 cases with pathologically confirmed breast cancer were analyzed retrospectively. Results: High-density mass with speculated margined, clusters of small calcification, stellate-like lesions were found in 51 cases, the rate of correct diagnosis was 96%-100%. Lobulated high-density mass were found in 17 cases, the correct diagnosis rate was about 88.3% cases with skin thickening were all correctly diagnosed. Round mass, focal parenchymal asymmetry and unidentified lesions were found in 20 cases, the diagnosing rate was less than 20%. Conclusion: Round mass, focal parenchymal asymmetry and unidentified lesions were atypical mammographic features of breast cancer. These lesions were misdiagnosed frequently. It is essential to find the indirect signs and associated finding to avoid misdiagnosis. On the other hand, further ultrasound or MRI were helpful to improve the diagnosis by detecting mass in breast, showing cystic lesions and blood supply. (authors)

  17. Mammographic quantitative image analysis and biologic image composition for breast lesion characterization and classification

    Energy Technology Data Exchange (ETDEWEB)

    Drukker, Karen, E-mail: kdrukker@uchicago.edu; Giger, Maryellen L.; Li, Hui [Department of Radiology, University of Chicago, Chicago, Illinois 60637 (United States); Duewer, Fred; Malkov, Serghei; Joe, Bonnie; Kerlikowske, Karla; Shepherd, John A. [Radiology Department, University of California, San Francisco, California 94143 (United States); Flowers, Chris I. [Department of Radiology, University of South Florida, Tampa, Florida 33612 (United States); Drukteinis, Jennifer S. [Department of Radiology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, Florida 33612 (United States)

    2014-03-15

    Purpose: To investigate whether biologic image composition of mammographic lesions can improve upon existing mammographic quantitative image analysis (QIA) in estimating the probability of malignancy. Methods: The study population consisted of 45 breast lesions imaged with dual-energy mammography prior to breast biopsy with final diagnosis resulting in 10 invasive ductal carcinomas, 5 ductal carcinomain situ, 11 fibroadenomas, and 19 other benign diagnoses. Analysis was threefold: (1) The raw low-energy mammographic images were analyzed with an established in-house QIA method, “QIA alone,” (2) the three-compartment breast (3CB) composition measure—derived from the dual-energy mammography—of water, lipid, and protein thickness were assessed, “3CB alone”, and (3) information from QIA and 3CB was combined, “QIA + 3CB.” Analysis was initiated from radiologist-indicated lesion centers and was otherwise fully automated. Steps of the QIA and 3CB methods were lesion segmentation, characterization, and subsequent classification for malignancy in leave-one-case-out cross-validation. Performance assessment included box plots, Bland–Altman plots, and Receiver Operating Characteristic (ROC) analysis. Results: The area under the ROC curve (AUC) for distinguishing between benign and malignant lesions (invasive and DCIS) was 0.81 (standard error 0.07) for the “QIA alone” method, 0.72 (0.07) for “3CB alone” method, and 0.86 (0.04) for “QIA+3CB” combined. The difference in AUC was 0.043 between “QIA + 3CB” and “QIA alone” but failed to reach statistical significance (95% confidence interval [–0.17 to + 0.26]). Conclusions: In this pilot study analyzing the new 3CB imaging modality, knowledge of the composition of breast lesions and their periphery appeared additive in combination with existing mammographic QIA methods for the distinction between different benign and malignant lesion types.

  18. Image quality of digital mammography images produced using wet and dry laser imaging systems

    International Nuclear Information System (INIS)

    Al Khalifah, K.; Brindhaban, A.; AlArfaj, R.; Jassim, O.

    2006-01-01

    Introduction: A study was carried out to compare the quality of digital mammographic images printed or processed by a wet laser imaging system and a dedicated mammographic dry laser imaging system. Material and methods: Digital images of a tissue equivalent breast phantom were obtained using a GE Senographe 2000D digital mammography system and different target/filter combinations of the X-ray tube. These images were printed on films using the Fuji FL-IM D wet laser imaging system and the Kodak DryView 8600 dry laser imaging system. The quality of images was assessed in terms of detectability of microcalcifications and simulated tumour masses by five radiologists. In addition, the contrast index and speed index of the two systems were measured using the step wedge in the phantom. The unpaired, unequal variance t-test was used to test any statistically significant differences. Results: There were no significant (p < 0.05) differences between the images printed using the two systems in terms of microcalcification and tumour mass detectability. The wet system resulted in slightly higher contrast index while the dry system showed significantly higher speed index. Conclusion: Both wet and dry laser imaging systems can produce mammography images of good quality on which 0.2 mm microcalcifications and 2 mm tumour masses can be detected. Dry systems are preferable due to the absence of wet chemical processing and solid or liquid chemical waste. The wet laser imaging systems, however, still represent a useful alternative to dry laser imaging systems for mammography studies

  19. International Consortium on Mammographic Density: Methodology and Population Diversity captured across 22 Countries

    Science.gov (United States)

    McCormack, Valerie A.; Burton, Anya; dos-Santos-Silva, Isabel; Hipwell, John H.; Dickens, Caroline; Salem, Dorria; Kamal, Rasha; Hartman, Mikael; Ling Lee, Charmaine Pei; Chia, Kee-Seng; Ozmen, Vahit; Aribal, Mustafa Erkin; Flugelman, Anath Arzee; Lajous, Martín; Lopez-Riduara, Ruy; Rice, Megan; Romieu, Isabelle; Ursin, Giske; Qureshi, Samera; Ma, Huiyan; Lee, Eunjung; van Gils, Carla H.; Wanders, Johanna O.P.; Vinayak, Sudhir; Ndumia, Rose; Allen, Steve; Vinnicombe, Sarah; Moss, Sue; Lee, Jong Won; Kim, Jisun; Pereira, Ana; Garmendia, Maria Luisa; Sirous, Reza; Sirous, Mehri; Peplonska, Beata; Bukowska, Agnieszka; Tamimi, Rulla M.; Bertrand, Kimberly; Nagata, Chisato; Kwong, Ava; Vachon, Celine; Scott, Christopher; Perez-Gomez, Beatriz; Pollan, Marina; Maskarinec, Gertraud; Giles, Graham; Hopper, John; Stone, Jennifer; Rajaram, Nadia; Teo, Soo-Hwang; Mariapun, Shivaani; Yaffe, Martin J.; Schüz, Joachim; Chiarelli, Anna; Linton, Linda; Boyd, Norman F.

    2015-01-01

    Mammographic density (MD) is a quantitative trait, measurable in all women, and is among the strongest markers of breast cancer risk. The population-based epidemiology of MD has revealed genetic, lifestyle and societal/environmental determinants, but studies have largely been conducted in women with similar westernized lifestyles living in countries with high breast cancer incidence rates. To benefit from the heterogeneity in risk factors and their combinations worldwide, we created an International Consortium on Mammographic Density (ICMD) to pool individual-level epidemiological and MD data from general population studies worldwide. ICMD aims to characterize determinants of MD more precisely, and to evaluate whether they are consistent across populations worldwide. We included 11755 women, from 27 studies in 22 countries, on whom individual-level risk factor data were pooled and original mammographic images were re-read for ICMD by a core team to obtain standardized comparable MD data. In the present article, we present (i) the rationale for this consortium; (ii) characteristics of the studies and women included; and (iii) study methodology to obtain comparable MD data from original re-read films. We also highlight the risk factor heterogeneity captured by such an effort and, thus, the unique insight the pooled study promises to offer through wider exposure ranges, different confounding structures and enhanced power for sub-group analyses. PMID:26724463

  20. Preliminary Clinical Experience with a Combined Automated Breast Ultrasound and Digital Breast Tomosynthesis System.

    Science.gov (United States)

    Larson, Eric D; Lee, Won-Mean; Roubidoux, Marilyn A; Goodsitt, Mitchell M; Lashbrook, Chris; Davis, Cynthia E; Kripfgans, Oliver D; Carson, Paul L

    2018-03-01

    We analyzed the performance of a mammographically configured, automated breast ultrasound (McABUS) scanner combined with a digital breast tomosynthesis (DBT) system. The GE Invenia ultrasound system was modified for integration with GE DBT systems. Ultrasound and DBT imaging were performed in the same mammographic compression. Our small preliminary study included 13 cases, six of whom had contained invasive cancers. From analysis of these cases, current limitations and corresponding potential improvements of the system were determined. A registration analysis was performed to compare the ease of McABUS to DBT registration for this system with that of two systems designed previously. It was observed that in comparison to data from an earlier study, the McABUS-to-DBT registration alignment errors for both this system and a previously built combined system were smaller than those for a previously built standalone McABUS system. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  1. EnviroAtlas - Percent Urban Land Cover by 12-Digit HUC for the Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset estimates the percent urban land for each 12-digit hydrologic unit code (HUC) in the conterminous United States. For the purposes of this...

  2. Wavelet processing techniques for digital mammography

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu

    1992-09-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Similar to traditional coarse to fine matching strategies, the radiologist may first choose to look for coarse features (e.g., dominant mass) within low frequency levels of a wavelet transform and later examine finer features (e.g., microcalcifications) at higher frequency levels. In addition, features may be extracted by applying geometric constraints within each level of the transform. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet representations, enhanced by linear, exponential and constant weight functions through scale space. By improving the visualization of breast pathology we can improve the chances of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  3. Cigarette smoking and mammographic density in the Danish Diet, Cancer and Health cohort

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp; Lynge, Elsebeth; Vejborg, Ilse

    2016-01-01

    with MD. METHODS: For the 5,356 women (4,489 postmenopausal) from the Danish Diet, Cancer and Health cohort (1993-1997) who attended mammographic screening in Copenhagen (1993-2001), we used MD (mixed/dense or fatty) assessed at the first screening after cohort entry. Active smoking (status, duration......PURPOSE: Smoking before first childbirth increases breast cancer risk, but the biological mechanism remains unknown and may involve mammographic density (MD), one of the strongest biomarkers of breast cancer risk. We aimed to examine whether active smoking and passive smoking were associated......, and intensity) and passive smoking were assessed at cohort baseline (1993-1997) via questionnaire, together with other breast cancer risk factors. Logistic regression was used to estimate associations (odds ratios, 95 % confidence intervals) between smoking and MD, adjusting for confounders. RESULTS: Two...

  4. State-wide provision of a digital mammography physics service : challenges and learning experiences

    International Nuclear Information System (INIS)

    Diffey, J.L.; Cartwright, L.E.; Collins, L.T.; Grewal, R.K.

    2010-01-01

    Full text: Breast Screen NSW is a fully digital screening programme with 70 mammographic units from eight vendors. We present the challenges and learning experiences associated with providing the physics service to this extensive screening programme. The EPA requires an annual check of Mean Glandular Dose and registration renewal every 2 years. Additionally, BreastScreen NSW requires annual compliance testing to RANZCR standards. To ensure that testing is carried out to a consistently high level, the contract specifies that only five physicists in the state are eligible to test the equipment. An equipment database has been developed to enable us to meet these deadlines. We have also created a radiog rapher QC manual. Two physicists take responsibility for the overall co-ordination of the service, reviewing reports and test methodology of other physics providers. The database has greatly improved the system for meeting deadlines; visits to all sites revealed that many were overdue. The radiographer QC manual has been accompanied by practical tutorials and has been successful in improving understanding of digital mam mography and ensuring consistency in testing. This has been a particular challenge because equipment has been supplied by a number of vendors, with a range of detector technology. The number of mammography units, combined with the range of vendor technology and frequency of testing has presented a challenge to both physicists and radiographers. It has been extremely beneficial to have two dedicated physicists in place to co-ordinate the service and ensure that the demands of the contract are met.

  5. Watershed Boundaries - WATERSHEDS_HUC06_USGS_IN: 6-Digit Accounting Units, Hydrologic Units, in Indiana, (Derived from US Geological Survey, 1:24,000 Polygon Shapefile)

    Data.gov (United States)

    NSGIC State | GIS Inventory — WATERSHEDS_HUC06_USGS_IN is a polygon shapefile showing the boundaries of accounting units (HUA) in Indiana. Accounting units are noted by a 6-digit hydrologic unit....

  6. The use of ultrasonography and digital mammography in women under 40 years with symptomatic breast cancer: a 7-year Irish experience.

    Science.gov (United States)

    Redmond, C E; Healy, G M; Murphy, C F; O'Doherty, A; Foster, A

    2017-02-01

    Breast cancer in women under 40 years of age is rare and typically presents symptomatically. The optimal imaging modality for this patient group is controversial. Most women undergo ultrasonography with/without mammography. Young women typically have dense breasts, which can obscure the features of malignancy on film mammography, however, initial studies have suggested that digital mammography may have a more accurate diagnostic performance in younger women. Ultrasound generally performs well in this age group, although it is poor at detecting carcinoma in situ (DCIS). To evaluate the comparative diagnostic performance of ultrasonography and digital mammography in the initial diagnostic evaluation of women under 40 years of age with symptomatic breast cancer. Retrospective review of all women under the age of 40 years managed at our symptomatic breast cancer unit from January 2009 to December 2015. There were 120 patients that met the inclusion criteria for this study. The sensitivity of ultrasonography and digital mammography for breast cancer in this patient group was 95.8 and 87.5 %, respectively. The patients with a false negative mammographic examination were more likely to have dense breasts (p breast cancer in women under the age of 40 years, however, the results show that digital mammography has an important complimentary role in the comprehensive assessment of these patients, particularly in the diagnosis of DCIS.

  7. The significance of circumscribed malignant mammographic masses in the surveillance of BRCA 1/2 gene mutation carriers

    International Nuclear Information System (INIS)

    Kaas, R.; Kroger, R.; Besnard, A.P.E.; Koops, W.; Pameijer, F.A.; Prevoo, W.; Loo, C.E.; Muller, S.H.; Hendriks, J.H.C.L.

    2004-01-01

    Breast cancers in gene mutation carriers may escape mammographic detection because of rapid growth and tumor expansion. Therefore, they may mimic benign lesions on the mammogram. Twenty-nine BRCA 1/2 mutation carriers under surveillance developed 31 breast cancers between 1994 and 2001 at a mean age of 44.2 years. Controls were 63 women with 67 breast cancers in the same period at a mean age of 53.8 years, also under surveillance because of a life time risk of at least 15%. In 26% of the carriers vs. 48% of the controls, mammography was the method that first suspected a malignancy. Seven radiologists performed a retrospective review of the original mammograms to establish technical assessment, with special attention for circumscribed lesions and estimated probability of malignancy. In the mutation carriers seven (23%) circumscribed non-calcified mammographic masses were found and three in the controls (4.5%) P=0.01. These masses were proven to be malignant. In both groups around 70% of these fast-growing circumscribed lesions were detected by the patients. The masses were situated in breasts with a good interpretable breast pattern. BRCA 1/2 mutation carriers had a significantly higher percentage of circumscribed non-calcified mammographic masses that proved to be malignant. These mammographic lesions in women at high risk should be described as at least Birads 0 and worked-up with ultrasound and needle biopsy. (orig.)

  8. The mammographic spectrum of intraductal carcinoma

    International Nuclear Information System (INIS)

    Ikeda, D.M.; Andersson, I.

    1988-01-01

    To analyze the atypical radiographic spectrum of ductal carcinoma in situ (DCIS), the authors retrospectively reviewed the mammograms of 190 women who had biopsy-proved DCIS at Malmo General Hospital between January 1976 and March 1988. Of these, 117 (61.6%) showed clustered microcalcifications as the major abnormality, a finding often associated with DCIS. The remaining 73 women (38.4%) had either negative mammograms (30 women) or radiographic findings not usually associated with DCIS (43 women), including circumscribed masses (15 women) and focal conglomerates of prominent ducts and nodules (12 cases). Since treatment of DCIS may cure the disease, the radiologist should learn to recognize the more unusual mammographic manifestations of intraductal carcinoma

  9. Correlation between mammographic findings and corresponding histopathology. Potential predictors for biological characteristics of breast diseases

    International Nuclear Information System (INIS)

    Tamaki, Kentaro; Ishida, Takanori; Miyashita, Minoru; Amari, Masakazu; Ohuchi, Noriaki; Tamaki, Nobumitsu; Sasano, Hironobu

    2011-01-01

    The present study retrospectively evaluated the mammographic findings of 606 Japanese women with breast cancer (median age 50 years; range 27-89 years) and correlated them with histopathological characteristics. Mammographic findings were evaluated with an emphasis on mass shape, margin, density, calcification, and the presence of architectural distortion; these findings were correlated with histopathological characteristics such as intrinsic subtype, histological grade, lymphovascular invasion, and the Ki-67 labeling index. An irregular mass shape and masses with a spiculated margin were significantly higher in the group of patients with luminal A breast cancer than in patients with masses that were lobular or round, or in tumors with an indistinct or microlobulated periphery (P=0.017, P=0.024, P<0.001, and P=0.001, respectively). Irregular mass shape and spiculated periphery were significantly lower in patients with Grade 3 cancer (P<0.001 for both). In terms of lymphovascular invasion, there were significant differences between oval and irregular or round mass shape (P=0.008 and P=0.034), between tumors with a microlobulated and indistinct periphery (P=0.014), between tumors with a punctate and amorphous or pleomorphic calcification shape (P=0.030 and 0.038), and between the presence and absence of architectural distortion (P=0.027). Equivalent or low-density masses were also higher in Grade 1 breast cancers (P=0.007). There were significant differences in the Ki-67 labeling index between irregular and lobular or round tumors (P<0.001 and P=0.014), as well as between spiculated and indistinct or microlobulated tumors (P<0.001 for both). Significant differences were noted in the mammographic features of different primary breast cancer subtypes. These proposed mammographic diagnostic criteria based on biological characteristics may contribute to a more accurate prediction of biological behavior of breast malignancies. (author)

  10. Mapping 3D breast lesions from full-field digital mammograms using subject-specific finite element models

    Science.gov (United States)

    García, E.; Oliver, A.; Diaz, O.; Diez, Y.; Gubern-Mérida, A.; Martí, R.; Martí, J.

    2017-03-01

    Patient-specific finite element (FE) models of the breast have received increasing attention due to the potential capability of fusing images from different modalities. During the Magnetic Resonance Imaging (MRI) to X-ray mammography registration procedure, the FE model is compressed mimicking the mammographic acquisition. Subsequently, suspicious lesions in the MRI volume can be projected into the 2D mammographic space. However, most registration algorithms do not provide the reverse information, avoiding to obtain the 3D geometrical information from the lesions localized in the mammograms. In this work we introduce a fast method to localize the 3D position of the lesion within the MRI, using both cranio-caudal (CC) and medio-lateral oblique (MLO) mammographic projections, indexing the tetrahedral elements of the biomechanical model by means of an uniform grid. For each marked lesion in the Full-Field Digital Mammogram (FFDM), the X-ray path from source to the marker is calculated. Barycentric coordinates are computed in the tetrahedrons traversed by the ray. The list of elements and coordinates allows to localize two curves within the MRI and the closest point between both curves is taken as the 3D position of the lesion. The registration errors obtained in the mammographic space are 9.89 +/- 3.72 mm in CC- and 8.04 +/- 4.68 mm in MLO-projection and the error in the 3D MRI space is equal to 10.29 +/- 3.99 mm. Regarding the uniform grid, it is computed spending between 0.1 and 0.7 seconds. The average time spent to compute the 3D location of a lesion is about 8 ms.

  11. Remote Patient Management in a Mammographic Screening Environment in Underserved Areas

    Science.gov (United States)

    2005-09-01

    of 4,945 paired examinations. Radiology 2001; 218:873-880. 10. Malich A, Marx C, Facius M, Boehm T, Fleck M, Kaiser WA. Tumour 24. Venta LA, Hendrick...218:873-880. KF, Sickles EA. Mammographic character- factor determining the quality of com- 15. Venta LA, Hendrick RE, Adler YT, et al. iSicks of 115

  12. EnviroAtlas - Historic Places by 12-digit HUC for the Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset portrays the total number of historic places located within each 12-digit Hydrologic Unit (HUC). The historic places data were compiled from...

  13. Anthropometric parameters: weight height, body mass index and mammary volume in relationship with the mammographic pattern

    International Nuclear Information System (INIS)

    Perez-Candela, V.; Busto, C.; Avila, R.; Marrero, M. G.; Liminana, J. M.; Orengo, J. C.

    2001-01-01

    A prospective study to attempt to relate the anthropometric parameters of height, weight, body mass index as well as age with the mammographic patterns obtained for the patients and obtain an anthropometric profile was carried out. The study was performed in 1.000 women who underwent a mammography in cranial-caudal and medial lateral oblique projection of both breasts, independently of whether they were screened or diagnosed. Prior to the performance of the mammography, weight and height were obtained, and this was also performed by the same technicians, and the patient were asked their bra size to deduce breast volume. With the weight, the body mass index of Quetelet was calculated (weight [kg]/height''2 (ml). After reading the mammography, the patient was assigned to one of the four mammographic patterns considered in the BIRADS (Breast Imaging Reporting and Data System) established by the ACR (American College of Radiology): type I (fat). type II (disperse fibroglandular densities), type III (fibroglandular densities distributed heterogeneously), type 4 (dense). The results were introduced into a computer database and the SPSS 8.0 statistical program was applied, using the statistical model of multivariant logistic regression. In women under 40 years, with normal weight, the dense breast pattern accounted for 67.8% and as the body mass index (BMI) increased, this pattern decreased to 25.1%. The fat pattern is 20% and as the BMI increases, this increased to 80%. In 40-60 year old women with normal weight, the dense pattern accounts for 44% and decreases to 20.9% in the grades II, III and IV obese. The fat pattern is 11.1% and increases to 53.7% in the grade II, III and IV obese. In women over 60 with normal, the dense pattern accounts for 19.3% and and decreases to 13% in the grade III obese. The fat pattern is 5.3% and increases to 20.2% in the grade iii of obesity. As age increases, the probability of presenting a mammographic pattern with a fat image in the

  14. The accuracy of digital breast tomosynthesis compared with coned compression magnification mammography in the assessment of abnormalities found on mammography

    International Nuclear Information System (INIS)

    Morel, J.C.; Iqbal, A.; Wasan, R.K.; Peacock, C.; Evans, D.R.; Rahim, R.; Goligher, J.; Michell, M.J.

    2014-01-01

    Aim: To compare the diagnostic accuracy of the digital breast tomosynthesis (DBT) with coned compression magnification mammography (CCMM). Materials and methods: The study design included two reading sessions completed by seven experienced radiologists. In the first session, all readers read bilateral standard two-view mammograms and a CCMM view of the lesion before giving a combined score for assessment. In the second session, readers read bilateral standard two-view mammograms plus one-view DBT. The two reading sessions of the experiment were separated by at least 2 weeks to reduce the chance of reader memory of the images read in the previous session from influencing the performance in the subsequent session. Results: Three hundred and fifty-four lesions were assessed and receiver-operative characteristic (ROC) analysis was used to evaluate the difference between the two modes. For standard two-view mammography plus CCMM, the area under the curve (AUC) was 0.87 [95% confidence interval (CI): 0.83–0.91] and for standard two-view mammography plus DBT the AUC was 0.93 (95% CI: 0.91–0.95). The difference between the AUCs was 0.06 with p-value of 0.0014. Conclusion: Two-view mammography with one-view DBT showed significantly improved accuracy compared to two-view mammography and CCMM in the assessment of mammographic abnormalities. These results show that DBT can be used effectively in the further evaluation of mammographic abnormalities found at screening and in symptomatic diagnostic practice. - Highlights: • Diagnostic accuracy of magnification mammography and digital breast tomosynthesis. • There is statistical difference between CCMM and DBT. • DBT has a role in evaluating mammographic abnormalities

  15. Genome-wide association study identifies multiple loci associated with both mammographic density and breast cancer risk

    Science.gov (United States)

    Lindström, Sara; Thompson, Deborah J.; Paterson, Andrew D.; Li, Jingmei; Gierach, Gretchen L.; Scott, Christopher; Stone, Jennifer; Douglas, Julie A.; dos-Santos-Silva, Isabel; Fernandez-Navarro, Pablo; Verghase, Jajini; Smith, Paula; Brown, Judith; Luben, Robert; Wareham, Nicholas J.; Loos, Ruth J.F.; Heit, John A.; Pankratz, V. Shane; Norman, Aaron; Goode, Ellen L.; Cunningham, Julie M.; deAndrade, Mariza; Vierkant, Robert A.; Czene, Kamila; Fasching, Peter A.; Baglietto, Laura; Southey, Melissa C.; Giles, Graham G.; Shah, Kaanan P.; Chan, Heang-Ping; Helvie, Mark A.; Beck, Andrew H.; Knoblauch, Nicholas W.; Hazra, Aditi; Hunter, David J.; Kraft, Peter; Pollan, Marina; Figueroa, Jonine D.; Couch, Fergus J.; Hopper, John L.; Hall, Per; Easton, Douglas F.; Boyd, Norman F.; Vachon, Celine M.; Tamimi, Rulla M.

    2015-01-01

    Mammographic density reflects the amount of stromal and epithelial tissues in relation to adipose tissue in the breast and is a strong risk factor for breast cancer. Here we report the results from meta-analysis of genome-wide association studies (GWAS) of three mammographic density phenotypes: dense area, non-dense area and percent density in up to 7,916 women in stage 1 and an additional 10,379 women in stage 2. We identify genome-wide significant (P<5×10−8) loci for dense area (AREG, ESR1, ZNF365, LSP1/TNNT3, IGF1, TMEM184B, SGSM3/MKL1), non-dense area (8p11.23) and percent density (PRDM6, 8p11.23, TMEM184B). Four of these regions are known breast cancer susceptibility loci, and four additional regions were found to be associated with breast cancer (P<0.05) in a large meta-analysis. These results provide further evidence of a shared genetic basis between mammographic density and breast cancer and illustrate the power of studying intermediate quantitative phenotypes to identify putative disease susceptibility loci. PMID:25342443

  16. Variations of radiation intensity as a function of position in radiation field of a mammographic unit of 760 mm SID with Mo anode and 20 μm Mo added filter

    International Nuclear Information System (INIS)

    Noriah Jamal

    2001-01-01

    There are many effects that contribute to radiation field nonuniformity in mammography, including the heel effect and shorter source to image distance (SID), inverse square law and different photon path lengths through various attenuating media (the x-ray tube beryllium window, the added filter, the mirror, and the compression paddle) throughout the field. Variations of radiation intensity was investigated as a function of position in the radiation field (with compression paddle in place)of a mammographic unit in 760 mm SID with Mo anode and 20 μm Mo added filter. Reduction in radiation intensity along central axis of up to 19.40%, 19.13% and 19.34% were noted at 24, 26 and 28 kVp respectively. Radiation intensity also drops off to the left and right of the central axis. As a function of position in the field, we also found that the variations of optical density correlate well with the measured radiation intensity changes. (Author)

  17. Comparison of Mammographic Changes Across Three Different Fractionation Schedules for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Sibo [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Paster, Lina F. [Department of Radiology, Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Kim, Sinae [Biometrics Division, Rutgers Cancer Institute of New Jersey, and Department of Biostatistics, Rutgers School of Public Health, Rutgers, New Jersey (United States); Kirstein, Laurie [Division of Surgical Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Haffty, Bruce G.; Ferro, Adam [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Amorosa, Judith [Department of Radiology, Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States); Goyal, Sharad, E-mail: goyalsh@rutgers.edu [Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey and Rutgers Robert Wood Johnson Medical School, Rutgers, New Jersey (United States)

    2016-06-01

    Purpose: As the use of hypofractionated breast radiation therapy (RT) increases, so will the need for long-term data on post-RT mammographic changes. The purpose of the present study was to longitudinally compare the incidence of common mammographic sequelae seen after breast conserving surgery and RT in patients treated with accelerated partial breast irradiation (APBI), hypofractionated whole breast irradiation (HWBI), and conventionally fractionated whole breast irradiation (WBI). Methods and Materials: Patients treated with either APBI or HWBI after breast conserving therapy and with ≥3 mammograms of the treated breast were identified. They were matched 1:1 by age ±5 years to patients treated with WBI. The mammograms were evaluated for common post-RT breast findings by a mammographer who was unaware of the treatment. The outcomes were analyzed using a cumulative logistic regression model; P<.05 indicated statistically significance. Results: Of 89 patients treated with RT from 2006 to 2011, 29 had received APBI, 30 had received HWBI, and 30 had received WBI. Their median age was 60 years (range 33-83). A total of 605 mammograms were evaluated, with a median follow-up of 48 months. The treatment technique did not affect the severity of architectural distortion when the groups were evaluated longitudinally. The likelihood of finding skin thickening decreased with increasing follow-up duration (odds ratio 0.6; P<.001) adjusted for fractionation schemes. No differences were seen with respect to changes in skin thickening, fluid collections, or calcifications among the treatment groups, after adjustment for the follow-up time. The clinical characteristics, including age, race, T stage, and chemotherapy use, were not linked to the likelihood of finding several mammographic phenomena over time. Conclusions: Although specific post-treatment imaging findings evolved over time, RT fractionation did not alter the relative incidence or severity of architectural

  18. Towards an automatic tool for resolution evaluation of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    De Oliveira, J. E. E. [FUMEC, Av. Alfonso Pena 3880, CEP 30130-009 Belo Horizonte - MG (Brazil); Nogueira, M. S., E-mail: juliae@fumec.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, 31270-901, Belo Horizonte - MG (Brazil)

    2014-08-15

    Medical images are important for diagnosis purposes as they are related to patients medical history and pathology. Breast cancer represents a leading cause of death among women worldwide, and its early detection is the most effective method of reducing mortality. In a way to identify small structures with low density differences, a high image quality is required with the use of low doses of radiation. The analysis of the quality of the obtained image from a mammogram is performed from an image of a simulated breast and this is a fundamental key point for a program of quality control of mammography equipment s. In a control program of mammographic equipment s, besides the analysis of the quality of mammographic images, each element of the chain which composes the formation of the image is also analyzed: X-rays equipment s, radiographic films, and operating conditions. This control allows that an effective and efficient exam can be provided to the population and is within the standards of quality required for the early detection of breast cancer. However, according to the State Program of Quality Control in Mammography of Minas Gerais, Brazil, only 40% of the mammographies have provided a simulated image with a minimum level of quality, thus reinforcing the need for monitoring the images. The reduction of the morbidity and mortality indexes, with optimization and assurance of access to diagnosis and breast cancer treatment in the state of Minas Gerais, Brazil, may be the result of a mammographic exam which has a final image with good quality and which automatic evaluation is not subjective. The reason is that one has to consider the hypothesis that humans are subjective when performing the image analysis and that the evaluation of the image can be executed by a computer with objectivity. In 2007, in order to maintain the standard quality needed to mammography, the State Health Secretariat of Minas Gerais, Brazil, established a Program of Monthly Monitoring the

  19. Towards an automatic tool for resolution evaluation of mammographic images

    International Nuclear Information System (INIS)

    De Oliveira, J. E. E.; Nogueira, M. S.

    2014-08-01

    Medical images are important for diagnosis purposes as they are related to patients medical history and pathology. Breast cancer represents a leading cause of death among women worldwide, and its early detection is the most effective method of reducing mortality. In a way to identify small structures with low density differences, a high image quality is required with the use of low doses of radiation. The analysis of the quality of the obtained image from a mammogram is performed from an image of a simulated breast and this is a fundamental key point for a program of quality control of mammography equipment s. In a control program of mammographic equipment s, besides the analysis of the quality of mammographic images, each element of the chain which composes the formation of the image is also analyzed: X-rays equipment s, radiographic films, and operating conditions. This control allows that an effective and efficient exam can be provided to the population and is within the standards of quality required for the early detection of breast cancer. However, according to the State Program of Quality Control in Mammography of Minas Gerais, Brazil, only 40% of the mammographies have provided a simulated image with a minimum level of quality, thus reinforcing the need for monitoring the images. The reduction of the morbidity and mortality indexes, with optimization and assurance of access to diagnosis and breast cancer treatment in the state of Minas Gerais, Brazil, may be the result of a mammographic exam which has a final image with good quality and which automatic evaluation is not subjective. The reason is that one has to consider the hypothesis that humans are subjective when performing the image analysis and that the evaluation of the image can be executed by a computer with objectivity. In 2007, in order to maintain the standard quality needed to mammography, the State Health Secretariat of Minas Gerais, Brazil, established a Program of Monthly Monitoring the

  20. Computer-aided detection system applied to full-field digital mammograms

    International Nuclear Information System (INIS)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella; Munoz Cacho, Pedro; Hoffmeister, Jeffrey W.

    2010-01-01

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  1. Computer-aided detection system applied to full-field digital mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Vega Bolivar, Alfonso; Sanchez Gomez, Sonia; Merino, Paula; Alonso-Bartolome, Pilar; Ortega Garcia, Estrella (Dept. of Radiology, Univ. Marques of Valdecilla Hospital, Santander (Spain)), e-mail: avegab@telefonica.net; Munoz Cacho, Pedro (Dept. of Statistics, Univ. Marques of Valdecilla Hospital, Santander (Spain)); Hoffmeister, Jeffrey W. (iCAD, Inc., Nashua, NH (United States))

    2010-12-15

    Background: Although mammography remains the mainstay for breast cancer screening, it is an imperfect examination with a sensitivity of 75-92% for breast cancer. Computer-aided detection (CAD) has been developed to improve mammographic detection of breast cancer. Purpose: To retrospectively estimate CAD sensitivity and false-positive rate with full-field digital mammograms (FFDMs). Material and Methods: CAD was used to evaluate 151 cases of ductal carcinoma in situ (DCIS) (n=48) and invasive breast cancer (n=103) detected with FFDM. Retrospectively, CAD sensitivity was estimated based on breast density, mammographic presentation, histopathology type, and lesion size. CAD false-positive rate was estimated with screening FFDMs from 200 women. Results: CAD detected 93% (141/151) of cancer cases: 97% (28/29) in fatty breasts, 94% (81/86) in breasts containing scattered fibroglandular densities, 90% (28/31) in heterogeneously dense breasts, and 80% (4/5) in extremely dense breasts. CAD detected 98% (54/55) of cancers manifesting as calcifications, 89% (74/83) as masses, and 100% (13/13) as mixed masses and calcifications. CAD detected 92% (73/79) of invasive ductal carcinomas, 89% (8/9) of invasive lobular carcinomas, 93% (14/15) of other invasive carcinomas, and 96% (46/48) of DCIS. CAD sensitivity for cancers 1-10 mm was 87% (47/54); 11-20 mm, 99% (70/71); 21-30 mm, 86% (12/14); and larger than 30 mm, 100% (12/12). The CAD false-positive rate was 2.5 marks per case. Conclusion: CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications or masses. CAD sensitivity was maintained in small lesions (1-20 mm) and invasive lobular carcinomas, which have lower mammographic sensitivity

  2. Monitoring the consistency of the dynalyser output via digital display unit and calculated practical peak voltage

    International Nuclear Information System (INIS)

    Wan Hazlinda Ismail; Muhammad Jamal Mohd Isa; Abdul Aziz Mohd Ramli; Shahrul Azlan Azizan

    2010-01-01

    This study was carried out to ensure the adequacy and accuracy of the Dynalyser Digital Display unit for measuring the true kVp from the invasive kVp meter unit during calibration of non-invasive kVp meters. An invasive high voltage divider (dynalyser) coupled to the x-ray system measures the true kilo voltage supplied to the x-ray tube. The kVp output measured was displayed via its digital display unit while its waveform was acquired using a calibrated oscilloscope. The waveform was used to calculate the Practical Peak Voltage (PPV) using the International Standard method adapted from IEC 61676 and treated as the true kVp value. The kVp output was measured at 9 points ranging between 40 kV-120 kV with interval steps of 10 kV and monitored every day. The test result was evaluated for variation of output, intrinsic error and limit of variation in compliance with the IEC standard. Results showed that kVp output measured by the display unit everyday is consistent with variations of not more than ±0.45 kV, intrinsic error of not more than ±0.009 kV and limits of variation of less than 1% which comply with the IEC standard requirement. The kVp output via digital display unit has a total uncertainty of not more than 2.8 kV (k=2) while the PPV output via oscilloscope has total uncertainty of not more than 0.75 kV (k=2). As a conclusion, the dynalyser digital display unit complies with standard requirement and can be used to measure the true kVp output during the calibration of non-invasive kVp meters. (author)

  3. Correlation between the physical performances measured from detectors and the diagnostic image quality in digital mammography

    International Nuclear Information System (INIS)

    Perez-Ponce, H.

    2009-05-01

    In digital mammography two approaches exist to estimate image quality. In the first approach, human observer assesses the lesion detection in mammograms. Unfortunately, such quality assessment is subject to interobserver variability, and requires a large amount of time and human resources. In the second approach, objective and human-independent parameters relating to image spatial resolution and noise (MTF and NPS) are used to evaluate digital detector performance; even if these parameters are objective, they are not directly related to lesion detection. A method leading to image quality assessment which is both human independent, and directly related to lesion detection is very important for the optimal use of mammographic units. This Ph.D thesis presents the steps towards such a method: the computation of realistic virtual images using an 'X ray source/digital detector' model taking into account the physical parameters of the detector (spatial resolution and noise measurements) measured under clinical conditions. From results obtained in this work, we have contributed to establish the link between the physical characteristics of detectors and the clinical quality of the image for usual exposition conditions. Furthermore, we suggest the use of our model for the creation of virtual images, in order to rapidly determine the optimal conditions in mammography, which usually is a long and tedious experimental process. This is an essential aspect to be taken into account for radioprotection of patients, especially in the context of organized mass screening of breast cancer. (author)

  4. A deep learning method for classifying mammographic breast density categories.

    Science.gov (United States)

    Mohamed, Aly A; Berg, Wendie A; Peng, Hong; Luo, Yahong; Jankowitz, Rachel C; Wu, Shandong

    2018-01-01

    Mammographic breast density is an established risk marker for breast cancer and is visually assessed by radiologists in routine mammogram image reading, using four qualitative Breast Imaging and Reporting Data System (BI-RADS) breast density categories. It is particularly difficult for radiologists to consistently distinguish the two most common and most variably assigned BI-RADS categories, i.e., "scattered density" and "heterogeneously dense". The aim of this work was to investigate a deep learning-based breast density classifier to consistently distinguish these two categories, aiming at providing a potential computerized tool to assist radiologists in assigning a BI-RADS category in current clinical workflow. In this study, we constructed a convolutional neural network (CNN)-based model coupled with a large (i.e., 22,000 images) digital mammogram imaging dataset to evaluate the classification performance between the two aforementioned breast density categories. All images were collected from a cohort of 1,427 women who underwent standard digital mammography screening from 2005 to 2016 at our institution. The truths of the density categories were based on standard clinical assessment made by board-certified breast imaging radiologists. Effects of direct training from scratch solely using digital mammogram images and transfer learning of a pretrained model on a large nonmedical imaging dataset were evaluated for the specific task of breast density classification. In order to measure the classification performance, the CNN classifier was also tested on a refined version of the mammogram image dataset by removing some potentially inaccurately labeled images. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to measure the accuracy of the classifier. The AUC was 0.9421 when the CNN-model was trained from scratch on our own mammogram images, and the accuracy increased gradually along with an increased size of training samples

  5. CADx of mammographic masses and clustered microcalcifications: A review

    International Nuclear Information System (INIS)

    Elter, Matthias; Horsch, Alexander

    2009-01-01

    Breast cancer is the most common type of cancer among women in the western world. While mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, the interpretation of mammograms is a difficult and error-prone task. Hence, computer aids have been developed that assist the radiologist in the interpretation of mammograms. Computer-aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer-aided diagnosis (CADx) systems have been proposed that assist the radiologist in the classification of mammographic lesions as benign or malignant. While a broad variety of approaches to both CADe and CADx systems have been published in the past two decades, an extensive survey of the state of the art is only available for CADe approaches. Therefore, a comprehensive review of the state of the art of CADx approaches is presented in this work. Besides providing a summary, the goals for this article are to identify relations, contradictions, and gaps in literature, and to suggest directions for future research. Because of the vast amount of publications on the topic, this survey is restricted to the two most important types of mammographic lesions: masses and clustered microcalcifications. Furthermore, it focuses on articles published in international journals.

  6. CADx of mammographic masses and clustered microcalcifications: A review

    Energy Technology Data Exchange (ETDEWEB)

    Elter, Matthias; Horsch, Alexander [Fraunhofer Institute for Integrated Circuits (IIS), Am Wolfsmantel 33, 91058 Erlangen (Germany); Institute for Medical Statistics and Epidemiology, TU Muenchen, Ismaninger Strasse 22, 81675 Muenchen (Germany) and Department of Computer Science, University of Tromsoe Breivika, N-9037 Tromsoe (Norway)

    2009-06-15

    Breast cancer is the most common type of cancer among women in the western world. While mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, the interpretation of mammograms is a difficult and error-prone task. Hence, computer aids have been developed that assist the radiologist in the interpretation of mammograms. Computer-aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer-aided diagnosis (CADx) systems have been proposed that assist the radiologist in the classification of mammographic lesions as benign or malignant. While a broad variety of approaches to both CADe and CADx systems have been published in the past two decades, an extensive survey of the state of the art is only available for CADe approaches. Therefore, a comprehensive review of the state of the art of CADx approaches is presented in this work. Besides providing a summary, the goals for this article are to identify relations, contradictions, and gaps in literature, and to suggest directions for future research. Because of the vast amount of publications on the topic, this survey is restricted to the two most important types of mammographic lesions: masses and clustered microcalcifications. Furthermore, it focuses on articles published in international journals.

  7. Risk stratification of women with false-positive test results in mammography screening based on mammographic morphology and density

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Lynge, Elsebeth

    2017-01-01

    a case-control study nested in the population-based screening programme in Copenhagen, Denmark. We included 288 cases and 288 controls based on a cohort of 4743 women with at least one FP-test result in 1991–2005 who were followed up until 17 April 2008. Film-based mammograms were assessed using...... the Breast Imaging-Reporting and Data System (BI-RADS) density classification, the Tabár classification, and two automated techniques quantifying percentage mammographic density (PMD) and mammographic texture (MTR), respectively. The association with breast cancer was estimated using binary logistic...

  8. International Consortium on Mammographic Density : Methodology and population diversity captured across 22 countries

    NARCIS (Netherlands)

    McCormack, Valerie A; Burton, Anya; Dos-Santos-Silva, Isabel; Hipwell, John H; Dickens, Caroline; Salem, Dorria; Kamal, Rasha; Hartman, Mikael; Lee, Charmaine Pei Ling; Chia, Kee-Seng; Ozmen, Vahit; Aribal, Mustafa Erkin; Flugelman, Anath Arzee; Lajous, Martín; Lopez-Riduara, Ruy; Rice, Megan; Romieu, Isabelle; Ursin, Giske; Qureshi, Samera; Ma, Huiyan; Lee, Eunjung; van Gils, Carla H; Wanders, Johanna O P; Vinayak, Sudhir; Ndumia, Rose; Allen, Steve; Vinnicombe, Sarah; Moss, Sue; Won Lee, Jong; Kim, Jisun; Pereira, Ana; Garmendia, Maria Luisa; Sirous, Reza; Sirous, Mehri; Peplonska, Beata; Bukowska, Agnieszka; Tamimi, Rulla M; Bertrand, Kimberly; Nagata, Chisato; Kwong, Ava; Vachon, Celine; Scott, Christopher; Perez-Gomez, Beatriz; Pollan, Marina; Maskarinec, Gertraud; Giles, Graham; Hopper, John; Stone, Jennifer; Rajaram, Nadia; Teo, Soo-Hwang; Mariapun, Shivaani; Yaffe, Martin J; Schüz, Joachim; Chiarelli, Anna M; Linton, Linda; Boyd, Norman F

    2015-01-01

    Mammographic density (MD) is a quantitative trait, measurable in all women, and is among the strongest markers of breast cancer risk. The population-based epidemiology of MD has revealed genetic, lifestyle and societal/environmental determinants, but studies have largely been conducted in women with

  9. Breast calcifications. A standardized mammographic reporting and data system to improve positive predictive value

    International Nuclear Information System (INIS)

    Perugini, G.; Bonzanini, B.; Valentino, C.

    1999-01-01

    The purpose of this work is to investigate the usefulness of a standardized reporting and data system in improving the positive predictive value of mammography in breast calcifications. Using the Breast Imaging Reporting and Data System lexicon developed by the American College of Radiology, it is defined 5 descriptive categories of breast calcifications and classified diagnostic suspicion of malignancy on a 3-grade scale (low, intermediate and high). Two radiologists reviewed 117 mammographic studies selected from those of the patients submitted to surgical biopsy for mammographically detected calcifications from January 1993 to December 1997, and classified them according to the above criteria. The positive predictive value was calculated for all examinations and for the stratified groups. Defining a standardized system for assessing and describing breast calcifications helps improve the diagnostic accuracy of mammography in clinical practice [it

  10. Regional trends in breast cancer incidence and mortality in Denmark prior to mammographic screening

    DEFF Research Database (Denmark)

    Andreasen, A H; Andersen, K W; Madsen, Mette

    1994-01-01

    To provide a basis for the evaluation of mammographic screening programmes in Denmark, a study was undertaken of the regional differences in breast cancer incidence and mortality. All 16 regions were followed for the 20 year period, 1970-89, before the start of the first population...... among women below age 60. The mortality was more stable, changing only from 24 to 28 (per 100,000 standardised WSP), but a significant increase occurred in the late 1980s. The study showed regional differences in both incidence and mortality of breast cancer in Denmark. Both the incidence......-based mammographic screening programme in the Copenhagen municipality in 1991. Multiplicative Poisson models were used for the analysis. In general, the incidence increased during this period from 55 to 70 [per 100,000 standardised world standard population (WSP)], and the analysis shows this to be most pronounced...

  11. Hexagonal wavelet processing of digital mammography

    Science.gov (United States)

    Laine, Andrew F.; Schuler, Sergio; Huda, Walter; Honeyman-Buck, Janice C.; Steinbach, Barbara G.

    1993-09-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms and used to enhance features of importance to mammography within a continuum of scale-space. We present a method of contrast enhancement based on an overcomplete, non-separable multiscale representation: the hexagonal wavelet transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by local and global non-linear operators. Multiscale edges identified within distinct levels of transform space provide local support for enhancement. We demonstrate that features extracted from multiresolution representations can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  12. The use of the Statscan digital X-ray unit in paediatric polytrauma

    Energy Technology Data Exchange (ETDEWEB)

    Pitcher, Richard D. [University of Cape Town, Division of Paediatric Radiology, Red Cross War Memorial Children' s Hospital, School of Child and Adolescent Health, Cape Town (South Africa); Wilde, Jim C.H. [University of Cape Town, Division of Paediatric Surgery, Red Cross War Memorial Children' s Hospital, School of Child and Adolescent Health, Cape Town (South Africa); University of Amsterdam, Paediatric Surgical Centre of Amsterdam, Emma Children' s Hospital, Academic Medical Centre, Amsterdam (Netherlands); Douglas, Tania S. [University of Cape Town, MRC/UCT Medical Imaging Research Unit, Department of Human Biology, Cape Town (South Africa); As, Arjan Bastiaan van [University of Cape Town, Division of Paediatric Surgery, Red Cross War Memorial Children' s Hospital, School of Child and Adolescent Health, Cape Town (South Africa)

    2009-05-15

    We present a 3-year review of clinical paediatric experience with the statscan (Lodox Systems, Johannesburg, South Africa), a low-dose, digital, whole-body, slit-scanning X-ray machine. While focusing on the role of the unit in paediatric polytrauma, insight into its applications in other paediatric settings is provided. (orig.)

  13. The use of the Statscan digital X-ray unit in paediatric polytrauma

    International Nuclear Information System (INIS)

    Pitcher, Richard D.; Wilde, Jim C.H.; Douglas, Tania S.; As, Arjan Bastiaan van

    2009-01-01

    We present a 3-year review of clinical paediatric experience with the statscan (Lodox Systems, Johannesburg, South Africa), a low-dose, digital, whole-body, slit-scanning X-ray machine. While focusing on the role of the unit in paediatric polytrauma, insight into its applications in other paediatric settings is provided. (orig.)

  14. Mammographic Screening of Women Attending a Reference Service Center in Southern Brazil.

    Science.gov (United States)

    Romeiro Lopes, Tiara Cristina; Franca Gravena, Angela Andreia; Demitto, Marcela de Oliveira; Brischiliari, Sheila Cristina Rocha; Borghesan, Deise Helena Pelloso; Dell Agnolo, Catia Millene; Carvalho, Maria Dalva de Barros; Pelloso, Sandra Marisa

    2016-01-01

    To investigate the prevalence of and factors associated with performance of annual mammography by women above 40 years of age. This cross-sectional retrospective study was conducted at an oncology reference service in Southern Brazil from October 2013 to October 2014 with 525 women aged 40 years or older. The prevalence of annual mammography was 54.1%; annual mammographic screening was performed for women without private medical insurance, who were under hormone replacement therapy and who had used contraception in the past. An association was found between non-performance of breast clinical and self-examination and non-performance of mammographic screening. Use of mammography for breast cancer screening in the public health care setting proved to be accessible; nevertheless, the proportion of screened women was low, and they exhibited poor adherence to the basic measures of care recommended for breast assessment. Thus, control of breast cancer requires implementing actions targeting the population most vulnerable to non-adherence to screening in addition to continuously monitoring and assessing that population to reduce the prevalence of this disease.

  15. Scatter radiation intensities around a clinical digital breast tomosynthesis unit and the impact on radiation shielding considerations

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Kai, E-mail: kyang11@mgh.harvard.edu; Li, Xinhua; Liu, Bob [Division of Diagnostic Imaging Physics, Department of Radiology, Massachusetts General Hospital, 55 Fruit Street, Boston, Massachusetts 02114 (United States)

    2016-03-15

    Purpose: To measure the scattered radiation intensity around a clinical digital breast tomosynthesis (DBT) unit and to provide updated data for radiation shielding design for DBT systems with tungsten-anode x-ray tubes. Methods: The continuous distribution of scattered x-rays from a clinical DBT system (Hologic Selenia Dimensions) was measured within an angular range of 0°–180° using a linear-array x-ray detector (X-Scan 0.8f3-512, Detection Technology, Inc., Finland), which was calibrated for the x-ray spectrum range of the DBT unit. The effects of x-ray field size, phantom size, and x-ray kVp/filter combination were investigated. Following a previously developed methodology by Simpkin, scatter fraction was determined for the DBT system as a function of angle around the phantom center. Detailed calculations of the scatter intensity from a DBT system were demonstrated using the measured scatter fraction data. Results: For the 30 and 35 kVp acquisition, the scatter-to-primary-ratio and scatter fraction data closely matched with data previously measured by Simpkin. However, the measured data from this study demonstrated the nonisotropic distribution of the scattered radiation around a DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous survey performed at MGH, the scatter air kerma at 1 m from the phantom center for wall/door is 1.76 × 10{sup −2} mGy patient{sup −1}, for floor is 1.64 × 10{sup −1} mGy patient{sup −1}, and for ceiling is 3.66 × 10{sup −2} mGy patient{sup −1}. Conclusions: Comparing to previously measured data for mammographic systems, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload (measured with total mAs/week), added tomosynthesis acquisition, and strong small angle forward scattering. Due to the

  16. Primary breast osteosarcoma mimicking calcified fibroadenoma on screening digital breast tomosynthesis mammogram

    Directory of Open Access Journals (Sweden)

    Debbie Lee Bennett, MD

    2017-12-01

    Full Text Available Primary breast osteosarcoma is a rare malignancy, with mostly case reports in the literature. The appearance of breast osteosarcoma on digital breast tomosynthesis imaging has not yet been described. A 69-year-old woman presents for routine screening mammography and is found to have a calcified mass in her right breast. Pattern of calcification appeared “sunburst” on digital breast tomosynthesis images. This mass was larger than on the previous year's mammogram, at which time it had been interpreted as a benign calcified fibroadenoma. The subsequent workup demonstrated the mass to reflect primary breast osteosarcoma. The patient's workup and treatment are detailed in this case. Primary breast osteosarcoma, although rare, should be included as a diagnostic consideration for breast masses with a sunburst pattern of calcifications, particularly when the mammographic appearance has changed.

  17. Development of a sampling strategy and sample size calculation to estimate the distribution of mammographic breast density in Korean women.

    Science.gov (United States)

    Jun, Jae Kwan; Kim, Mi Jin; Choi, Kui Son; Suh, Mina; Jung, Kyu-Won

    2012-01-01

    Mammographic breast density is a known risk factor for breast cancer. To conduct a survey to estimate the distribution of mammographic breast density in Korean women, appropriate sampling strategies for representative and efficient sampling design were evaluated through simulation. Using the target population from the National Cancer Screening Programme (NCSP) for breast cancer in 2009, we verified the distribution estimate by repeating the simulation 1,000 times using stratified random sampling to investigate the distribution of breast density of 1,340,362 women. According to the simulation results, using a sampling design stratifying the nation into three groups (metropolitan, urban, and rural), with a total sample size of 4,000, we estimated the distribution of breast density in Korean women at a level of 0.01% tolerance. Based on the results of our study, a nationwide survey for estimating the distribution of mammographic breast density among Korean women can be conducted efficiently.

  18. Spectral analysis of mammographic images using a multitaper method

    International Nuclear Information System (INIS)

    Wu Gang; Mainprize, James G.; Yaffe, Martin J.

    2012-01-01

    Purpose: Power spectral analysis in radiographic images is conventionally performed using a windowed overlapping averaging periodogram. This study describes an alternative approach using a multitaper technique and compares its performance with that of the standard method. This tool will be valuable in power spectrum estimation of images, whose content deviates significantly from uniform white noise. The performance of the multitaper approach will be evaluated in terms of spectral stability, variance reduction, bias, and frequency precision. The ultimate goal is the development of a useful tool for image quality assurance. Methods: A multitaper approach uses successive data windows of increasing order. This mitigates spectral leakage allowing one to calculate a reduced-variance power spectrum. The multitaper approach will be compared with the conventional power spectrum method in several typical situations, including the noise power spectra (NPS) measurements of simulated projection images of a uniform phantom, NPS measurement of real detector images of a uniform phantom for two clinical digital mammography systems, and the estimation of the anatomic noise in mammographic images (simulated images and clinical mammograms). Results: Examination of spectrum variance versus frequency resolution and bias indicates that the multitaper approach is superior to the conventional single taper methods in the prevention of spectrum leakage and variance reduction. More than four times finer frequency precision can be achieved with equivalent or less variance and bias. Conclusions: Without any shortening of the image data length, the bias is smaller and the frequency resolution is higher with the multitaper method, and the need to compromise in the choice of regions of interest size to balance between the reduction of variance and the loss of frequency resolution is largely eliminated.

  19. FROST: an ASIC for digital mammography with synchrotron radiation

    International Nuclear Information System (INIS)

    Bergamaschi, A.; Prest, M.; Vallazza, E.; Arfelli, F.; Dreossi, D.; Longo, R.; Olivo, A.; Pani, S.; Castelli, E.

    2003-01-01

    The FRONTier RADiography (FRONTRAD) collaboration is developing a digital system for mammography at the Elettra Synchrotron Light Source in Trieste. The system is based on a silicon microstrip detector array. The ASIC FROST (FRONTRAD Read Out sySTem) was developed as a collaboration between INFN Trieste and Aurelia Microelettronica and is designed to operate in single photon counting mode. FROST provides low-noise and high-gain performances and is able to work at incident photon rates higher than 100 kHz with almost 100% efficiency. The ASIC has been tested and the first images of mammographic test objects will be shown. The acquisition time per breast image should be of about 10 s

  20. A comparison of five methods of measuring mammographic density: a case-control study.

    Science.gov (United States)

    Astley, Susan M; Harkness, Elaine F; Sergeant, Jamie C; Warwick, Jane; Stavrinos, Paula; Warren, Ruth; Wilson, Mary; Beetles, Ursula; Gadde, Soujanya; Lim, Yit; Jain, Anil; Bundred, Sara; Barr, Nicola; Reece, Valerie; Brentnall, Adam R; Cuzick, Jack; Howell, Tony; Evans, D Gareth

    2018-02-05

    High mammographic density is associated with both risk of cancers being missed at mammography, and increased risk of developing breast cancer. Stratification of breast cancer prevention and screening requires mammographic density measures predictive of cancer. This study compares five mammographic density measures to determine the association with subsequent diagnosis of breast cancer and the presence of breast cancer at screening. Women participating in the "Predicting Risk Of Cancer At Screening" (PROCAS) study, a study of cancer risk, completed questionnaires to provide personal information to enable computation of the Tyrer-Cuzick risk score. Mammographic density was assessed by visual analogue scale (VAS), thresholding (Cumulus) and fully-automated methods (Densitas, Quantra, Volpara) in contralateral breasts of 366 women with unilateral breast cancer (cases) detected at screening on entry to the study (Cumulus 311/366) and in 338 women with cancer detected subsequently. Three controls per case were matched using age, body mass index category, hormone replacement therapy use and menopausal status. Odds ratios (OR) between the highest and lowest quintile, based on the density distribution in controls, for each density measure were estimated by conditional logistic regression, adjusting for classic risk factors. The strongest predictor of screen-detected cancer at study entry was VAS, OR 4.37 (95% CI 2.72-7.03) in the highest vs lowest quintile of percent density after adjustment for classical risk factors. Volpara, Densitas and Cumulus gave ORs for the highest vs lowest quintile of 2.42 (95% CI 1.56-3.78), 2.17 (95% CI 1.41-3.33) and 2.12 (95% CI 1.30-3.45), respectively. Quantra was not significantly associated with breast cancer (OR 1.02, 95% CI 0.67-1.54). Similar results were found for subsequent cancers, with ORs of 4.48 (95% CI 2.79-7.18), 2.87 (95% CI 1.77-4.64) and 2.34 (95% CI 1.50-3.68) in highest vs lowest quintiles of VAS, Volpara and Densitas

  1. The Future of Contrast-Enhanced Mammography.

    Science.gov (United States)

    Covington, Matthew F; Pizzitola, Victor J; Lorans, Roxanne; Pockaj, Barbara A; Northfelt, Donald W; Appleton, Catherine M; Patel, Bhavika K

    2018-02-01

    The purpose of this article is to discuss facilitators of and barriers to future implementation of contrast-enhanced mammography (CEM) in the United States. CEM provides low-energy 2D mammographic images analogous to digital mammography and contrast-enhanced recombined images that allow assessment of neovascularity similar to that offered by MRI. The utilization of CEM in the United States is currently low but could increase rapidly given the many potential indications for its clinical use.

  2. Should processed or raw image data be used in mammographic image quality analyses? A comparative study of three full-field digital mammography systems

    International Nuclear Information System (INIS)

    Borg, Mark; Badr, Ishmail; Royle, Gary

    2015-01-01

    The purpose of this study is to compare a number of measured image quality parameters using processed and unprocessed or raw images in two full-field direct digital units and one computed radiography mammography system. This study shows that the difference between raw and processed image data is system specific. The results have shown that there are no significant differences between raw and processed data in the mean threshold contrast values using the contrast-detail mammography phantom in all the systems investigated; however, these results cannot be generalised to all available systems. Notable differences were noted in contrast-to-noise ratios and in other tests including: response function, modulation transfer function, noise equivalent quanta, normalised noise power spectra and detective quantum efficiency as specified in IEC 62220-1-2. Consequently, the authors strongly recommend the use of raw data for all image quality analyses in digital mammography. (authors)

  3. Iso-precision scaling of digitized mammograms to facilitate image analysis

    International Nuclear Information System (INIS)

    Karssmeijer, N.; van Erning, L.

    1991-01-01

    This paper reports on a 12 bit CCD camera equipped with a linear sensor of 4096 photodiodes which is used to digitize conventional mammographic films. An iso-precision conversion of the pixel values is preformed to transform the image data to a scale on which the image noise is equal at each level. For this purpose film noise and digitization noise have been determined as a function of optical density and pixel size. It appears that only at high optical densities digitization noise is comparable to or larger than film noise. The quantization error caused by compression of images recorded with 12 bits per pixel to 8 bit images by an iso-precision conversion has been calculated as a function of the number of quantization levels. For mammograms digitized in a 4096 2 matrix the additional error caused by such a scale transform is only about 1.5 percent. An iso-precision scale transform can be advantageous when automated procedures for quantitative image analysis are developed. Especially when detection of signals in noise is aimed at, a constant noise level over the whole pixel value range is very convenient. This is demonstrated by applying local thresholding to detect small microcalcifications. Results are compared to those obtained by using logarithmic or linearized scales

  4. Male breast disease: clinical, mammographic, and ultrasonographic features

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-01-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination

  5. Male breast disease: clinical, mammographic, and ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Guenhan-Bilgen, Isil E-mail: isilbilgen@hotmail.com; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-09-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination.

  6. Genotypes and haplotypes in the insulin-like growth factors, their receptors and binding proteins in relation to plasma metabolic levels and mammographic density

    Directory of Open Access Journals (Sweden)

    Chanock Stephen J

    2010-03-01

    Full Text Available Abstract Background Increased mammographic density is one of the strongest independent risk factors for breast cancer. It is believed that one third of breast cancers are derived from breasts with more than 50% density. Mammographic density is affected by age, BMI, parity, and genetic predisposition. It is also greatly influenced by hormonal and growth factor changes in a woman's life cycle, spanning from puberty through adult to menopause. Genetic variations in genes coding for hormones and growth factors involved in development of the breast are therefore of great interest. The associations between genetic polymorphisms in genes from the IGF pathway on mammographic density and circulating levels of IGF1, its binding protein IGFBP3, and their ratio in postmenopausal women are reported here. Methods Samples from 964 postmenopausal Norwegian women aged 55-71 years were collected as a part of the Tromsø Mammography and Breast Cancer Study. All samples were genotyped for 25 SNPs in IGF1, IGF2, IGF1R, IGF2R, IGFALS and IGFBP3 using Taqman (ABI. The main statistical analyses were conducted with the PROC HAPLOTYPE procedure within SAS/GENETICS™ (SAS 9.1.3. Results The haplotype analysis revealed six haploblocks within the studied genes. Of those, four had significant associations with circulating levels of IGF1 or IGFBP3 and/or mammographic density. One haplotype variant in the IGF1 gene was found to be associated with mammographic density. Within the IGF2 gene one haplotype variant was associated with levels of both IGF1 and IGFBP3. Two haplotype variants in the IGF2R were associated with the level of IGF1. Both variants of the IGFBP3 haplotype were associated with the IGFBP3 level and indicate regulation in cis. Conclusion Polymorphisms within the IGF1 gene and related genes were associated with plasma levels of IGF1, IGFBP3 and mammographic density in this study of postmenopausal women.

  7. Early detection of breast cancer: benefits and risks of supplemental breast ultrasound in asymptomatic women with mammographically dense breast tissue. A systematic review

    International Nuclear Information System (INIS)

    Nothacker, Monika; Duda, Volker; Hahn, Markus; Warm, Mathias; Degenhardt, Friedrich; Madjar, Helmut; Weinbrenner, Susanne; Albert, Ute-Susann

    2009-01-01

    Mammographic screening alone will miss a certain fraction of malignancies, as evidenced by retrospective reviews of mammograms following a subsequent screening. Mammographic breast density is a marker for increased breast cancer risk and is associated with a higher risk of interval breast cancer, i.e. cancer detected between screening tests. The purpose of this review is to estimate risks and benefits of supplemental breast ultrasound in women with negative mammographic screening with dense breast tissue. A systematic search and review of studies involving mammography and breast ultrasound for screening of breast cancer was conducted. The search was performed for the period 1/2000-8/2008 within the data source of PubMed, DARE, and Cochrane databases. Inclusion and exclusion criteria were determined prospectively, and the Oxford evidence classification system for diagnostic studies was used for evidence level. The parameters biopsy rate, positive predictive value (PPV) for biopsy, cancer yield for breast ultrasound alone, and carcinoma detection rate by breast density were extracted or constructed. The systematic search identified no randomized controlled trials or systematic reviews, six cohort studies of intermediate level of evidence (3b) were found. Only two of the studies included adequate follow-up of subjects with negative or benign findings. Supplemental breast ultrasound after negative mammographic screening permitted diagnosis of primarily invasive carcinomas in 0.32% of women in breast density type categories 2-4 of the American College of Radiology (ACR); mean tumor size for those identified was 9.9 mm, 90% with negative lymph node status. Most detected cancers occurred in mammographically dense breast ACR types 3 and 4. Biopsy rates were in the range 2.3%-4.7%, with PPV of 8.4-13.7% for those biopsied due to positive ultrasound, or about one third of the PPV of biopsies due to mammography. Limitations: The study populations included wide age ranges, and

  8. False Negative Mammogram of Breast Cancer : Analysis of Mammographic and Sonographic Findings and Correlation with Clinical Findings

    International Nuclear Information System (INIS)

    Lee, Kil Jun; Lee, Ji Yeon; Han, Sung Nim; Jeong, Seong Ki; Tae, Seok; Shin, Kyoung Ja; Lee, Sang Chun

    1995-01-01

    Recent mammographic equipment have been of good quality and yielded high diagnostic accuracy for the detection of breast cancer. However, negative mammogram does not necessarily rule out breast cancer. Therefore were viewed cause of false negative mammography in confirmed breast cancer to improve diagnostic accuracy and for adequate clinical approach. We reviewed 19 cases of confirmed breast cancer, which showed false negative mammography with positive sonographic findings. Retrospective analysis was done by correlating the patient's age, sonographic finding and mass size, mammographic breast pattern and cause of false negative mammogram, and clinical symptoms. Among the 5 patients below 35 years in age, mass was not visible due to dense breast in 4 and due to small size in 1 case. In 14 patients over 35 years in age, 11 had normal mammographic findings, 4 had dense breast, and 7 had small sized mass. Remaining 3 cases showed asymmetric density in 2 and architecture distortion in 1 case. All showed mass lesion in sonography : ill defined malignant appearance in 14,well defined malignant appearance in 2, and well defined benign in 3 cases. Negative mammogram should be correlated with sonography in case of dense breast, below 35 years in age with palpable mass and under risk for breast cancer

  9. Residential traffic noise and mammographic breast density in the Diet, Cancer, and Health cohort

    DEFF Research Database (Denmark)

    Roswall, Nina; Andersen, Zorana Jovanovic; von Euler-Chelpin, My

    2018-01-01

    OBJECTIVES: Traffic is the most important source of community noise, and it has been proposed to be associated with a range of disease outcomes, including breast cancer. As mammographic breast density (MD) is one of the strongest risk factors for developing breast cancer, the present study...

  10. Clinicopathogical characteristics and mammographic features of breast cancer showing architectural distortion on a mammogram

    International Nuclear Information System (INIS)

    Kanzaki, Masao; Hirose, Naoko; Suwa, Kaori; Yoshida, Masayuki; Otuki, Yoshiro; Kobayashi, Hiroshi

    2012-01-01

    Seven hundred and twenty-seven cases of breast cancer were diagnosed in this clinic between January 2003 and December 2010. Of those, 97 patients who showed architectural distortion on mammography were examined regarding the clinicopathological characteristics and mammographic features. The overall rate of architectural distortion was 13.3%, which became higher with progression of the clinical stage. The rate of lymph node metastasis was 50.5% histologically, and the most common histological type was scirrhous carcinoma at 36.2%, papillotubular carcinoma at 33%, invasive lobular carcinoma at 12.1%, and ductal carcinoma in situ at 11%. Cases of extensive ductal spread beyond the breast quadrant, accompanied by microcalcifications or showing architectural distortion in two views on mammography, were present at significantly high rates. Cases showing architectural distortion in two views on mammography accounted for 66% of the total, and, when these cases were not associated with any other mammographic findings, the most suspected histology of the lesion was invasive lobular carcinoma or carcinoma in situ. (author)

  11. Computer-aided diagnosis of mammographic masses using geometric verification-based image retrieval

    Science.gov (United States)

    Li, Qingliang; Shi, Weili; Yang, Huamin; Zhang, Huimao; Li, Guoxin; Chen, Tao; Mori, Kensaku; Jiang, Zhengang

    2017-03-01

    Computer-Aided Diagnosis of masses in mammograms is an important indicator of breast cancer. The use of retrieval systems in breast examination is increasing gradually. In this respect, the method of exploiting the vocabulary tree framework and the inverted file in the mammographic masse retrieval have been proved high accuracy and excellent scalability. However it just considered the features in each image as a visual word and had ignored the spatial configurations of features. It greatly affect the retrieval performance. To overcome this drawback, we introduce the geometric verification method to retrieval in mammographic masses. First of all, we obtain corresponding match features based on the vocabulary tree framework and the inverted file. After that, we grasps the main point of local similarity characteristic of deformations in the local regions by constructing the circle regions of corresponding pairs. Meanwhile we segment the circle to express the geometric relationship of local matches in the area and generate the spatial encoding strictly. Finally we judge whether the matched features are correct or not, based on verifying the all spatial encoding are whether satisfied the geometric consistency. Experiments show the promising results of our approach.

  12. High-grade histologic features of DCIS are associated with R5 rather than R3 calcifications in breast screening mammography.

    LENUS (Irish Health Repository)

    Hayes, Brian D

    2013-01-01

    Mammographic calcification is an important radiologic feature of early breast carcinoma whose index of suspicion for malignancy may be reported by a five-tier R-category system. This study aims to describe the histologic diagnoses underlying screen-detected mammographic calcifications using both digital and screen-film mammography, and to correlate these findings with radiologic R-categories. Patients attending the Merrion Breast Screening Unit in Dublin between 2000 and 2011 were identified, who underwent needle-core biopsy for assessment of mammographic calcifications without associated mass or architectural distortion. Radiologic R-category was correlated with biopsy and excision histology reports. A total of 776 cases of calcification were identified, involving 769 individual patients. The radiologic R-categories were as follows: R3 513 (66.1%), R4 192 (24.7%), R5 71 (9.1%). The positive predictive values for malignancy were R3 32.6%, R4 69.8%, R5 95.8%. Several histologic features of DCIS were associated with R5 rather than R3 radiology: high nuclear grade, solid or cribriform architecture, necrosis, periductal inflammation or fibrosis, and associated microinvasive or invasive carcinoma. Mammographic lesions and histologic whole and invasive tumors increased in size from R3 to R5. Radiologic size of calcifications correlated with whole (but not invasive) tumor size, although it tended to underestimate it by several millimeters. Digital-detected calcifications were more likely than screen-film detected to be categorized as R3 and less likely R4 or R5, and there was no significant difference in positive predictive value between the two imaging techniques in any R-category. In conclusion, histologic features of DCIS, in particular those associated with high grade, are associated with R5 radiology. There is no significant difference in positive predictive value for malignancy in any R-category between digital and screen-film mammography.

  13. Development of a 14-digit Hydrologic Unit Code Numbering System for South Carolina

    Science.gov (United States)

    Bower, David E.; Lowry, Claude; Lowery, Mark A.; Hurley, Noel M.

    1999-01-01

    A Hydrologic Unit Map showing the cataloging units, watersheds, and subwatersheds of South Carolina has been developed by the U.S. Geological Survey in cooperation with the South Carolina Department of Health and Environmental Control, funded through a U.S. Environmental Protection Agency 319 Grant, and the U.S. Department of Agriculture, Natural Resources Conservation Service. These delineations represent 8-, 11-, and 14-digit Hydrologic Unit Codes, respectively. This map presents information on drainage, hydrography, and hydrologic boundaries of the water-resources regions, subregions, accounting units, cataloging units, watersheds, and subwatersheds. The source maps for the basin delineations are 1:24,000-scale 7.5-minute series topographic maps and the base maps are from 1:100,000-scale Digital Line Graphs; however, the data are published at a scale of 1:500,000. In addition, an electronic version of the data is provided on a compact disc.Of the 1,022 subwatersheds delineated for this project, 1,004 range in size from 3,000 to 40,000 acres (4.69 to 62.5 square miles). Seventeen subwatersheds are smaller than 3,000 acres and one subwatershed, located on St. Helena Island, is larger than 40,000 acres.This map and its associated codes provide a standardized base for use by water-resource managers and planners in locating, storing, retrieving, and exchanging hydrologic data. In addition, the map can be used for cataloging water-data acquisition activities, geographically organizing hydrologic data, and planning and describing water-use and related land-use activities.

  14. A novel deep learning-based approach to high accuracy breast density estimation in digital mammography

    Science.gov (United States)

    Ahn, Chul Kyun; Heo, Changyong; Jin, Heongmin; Kim, Jong Hyo

    2017-03-01

    Mammographic breast density is a well-established marker for breast cancer risk. However, accurate measurement of dense tissue is a difficult task due to faint contrast and significant variations in background fatty tissue. This study presents a novel method for automated mammographic density estimation based on Convolutional Neural Network (CNN). A total of 397 full-field digital mammograms were selected from Seoul National University Hospital. Among them, 297 mammograms were randomly selected as a training set and the rest 100 mammograms were used for a test set. We designed a CNN architecture suitable to learn the imaging characteristic from a multitudes of sub-images and classify them into dense and fatty tissues. To train the CNN, not only local statistics but also global statistics extracted from an image set were used. The image set was composed of original mammogram and eigen-image which was able to capture the X-ray characteristics in despite of the fact that CNN is well known to effectively extract features on original image. The 100 test images which was not used in training the CNN was used to validate the performance. The correlation coefficient between the breast estimates by the CNN and those by the expert's manual measurement was 0.96. Our study demonstrated the feasibility of incorporating the deep learning technology into radiology practice, especially for breast density estimation. The proposed method has a potential to be used as an automated and quantitative assessment tool for mammographic breast density in routine practice.

  15. Digital spot mammography using an add-on upright unit: diagnostic application in daily practice

    International Nuclear Information System (INIS)

    Mesurolle, Benoit; Mignon, Francois; Ariche-Cohen, Michele; Kao, Ellen; Gagnon, Jean H.; Goumot, Pierre-Alain

    2004-01-01

    Introduction: To present the use of digital spot mammography (DSM) in a diagnostic practice. Methods and patients: Digital spot images of 779 women requiring a spot compression or a spot magnification view were collected. The digital images were acquired on a digital spot upright unit using a 61 mmx61 mm field of view. Lesions reported included masses, calcifications, and areas of distortions. Results: 1065 lesions required additional views with DSM. Lesions reported included masses (n=113), masses and microcalcifications (n=53), spiculated masses (n=34), architectural distortions (n=16), and microcalcifications (n=849). DSMs were considered to be adequate in 97.7% of patients. Unsatisfactory exams resulted from difficulties encountered in targeting the area of interest at the beginning of our experience. Conclusion: DSM, most commonly used to perform interventional procedures, can also be used in a diagnostic practice taking advantage of post-processing of images not available with conventional spot compression and magnification

  16. Multimodal breast cancer imaging using coregistered dynamic diffuse optical tomography and digital breast tomosynthesis

    Science.gov (United States)

    Zimmermann, Bernhard B.; Deng, Bin; Singh, Bhawana; Martino, Mark; Selb, Juliette; Fang, Qianqian; Sajjadi, Amir Y.; Cormier, Jayne; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.; Saksena, Mansi A.; Carp, Stefan A.

    2017-04-01

    Diffuse optical tomography (DOT) is emerging as a noninvasive functional imaging method for breast cancer diagnosis and neoadjuvant chemotherapy monitoring. In particular, the multimodal approach of combining DOT with x-ray digital breast tomosynthesis (DBT) is especially synergistic as DBT prior information can be used to enhance the DOT reconstruction. DOT, in turn, provides a functional information overlay onto the mammographic images, increasing sensitivity and specificity to cancer pathology. We describe a dynamic DOT apparatus designed for tight integration with commercial DBT scanners and providing a fast (up to 1 Hz) image acquisition rate to enable tracking hemodynamic changes induced by the mammographic breast compression. The system integrates 96 continuous-wave and 24 frequency-domain source locations as well as 32 continuous wave and 20 frequency-domain detection locations into low-profile plastic plates that can easily mate to the DBT compression paddle and x-ray detector cover, respectively. We demonstrate system performance using static and dynamic tissue-like phantoms as well as in vivo images acquired from the pool of patients recalled for breast biopsies at the Massachusetts General Hospital Breast Imaging Division.

  17. Tumor characteristics and family history in relation to mammographic density and breast cancer: The French E3N cohort.

    Science.gov (United States)

    Maskarinec, Gertraud; Dartois, Laureen; Delaloge, Suzette; Hopper, John; Clavel-Chapelon, Françoise; Baglietto, Laura

    2017-08-01

    Mammographic density is a known heritable risk factor for breast cancer, but reports how tumor characteristics and family history may modify this association are inconsistent. Dense and total breast areas were assessed using Cumulus™ from pre-diagnostic mammograms for 820 invasive breast cancer cases and 820 matched controls nested within the French E3N cohort study. To allow comparisons across models, percent mammographic density (PMD) was standardized to the distribution of the controls. Odds ratios (OR) and 95% confidence intervals (CI) of breast cancer risk for mammographic density were estimated by conditional logistic regression while adjusting for age and body mass index. Heterogeneity according to tumor characteristic and family history was assessed using stratified analyses. Overall, the OR per 1 SD for PMD was 1.50 (95% CI, 1.33-1.69). No evidence for significant heterogeneity by tumor size, lymph node status, grade, and hormone receptor status (estrogen, progesterone, and HER2) was detected. However, the association of PMD was stronger for women reporting a family history of breast cancer (OR 1SD =2.25; 95% CI, 1.67-3.04) than in women reporting none (OR 1SD =1.41; 95% CI, 1.24-1.60; p heterogeneity =0.002). Similarly, effect modification by FHBC was observed using categories of PMD (p heterogeneity =0.02) with respective ORs of 15.16 (95% CI, 4.23-54.28) vs. 3.14 (95% CI, 1.89-5.22) for ≥50% vs. breast cancer risk with a family history supports the hypothesis of shared genetic factors responsible for familial aggregation of breast cancer and the heritable component of mammographic density. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  19. Varying performance in mammographic interpretation across two countries: Do results indicate reader or population variances?

    Science.gov (United States)

    Soh, BaoLin P.; Lee, Warwick B.; Wong, Jill; Sim, Llewellyn; Hillis, Stephen L.; Tapia, Kriscia A.; Brennan, Patrick C.

    2016-03-01

    Aim: To compare the performance of Australian and Singapore breast readers interpreting a single test-set that consisted of mammographic examinations collected from the Australian population. Background: In the teleradiology era, breast readers are interpreting mammographic examinations from different populations. The question arises whether two groups of readers with similar training backgrounds, demonstrate the same level of performance when presented with a population familiar only to one of the groups. Methods: Fifty-three Australian and 15 Singaporean breast radiologists participated in this study. All radiologists were trained in mammogram interpretation and had a median of 9 and 15 years of experience in reading mammograms respectively. Each reader interpreted the same BREAST test-set consisting of sixty de-identified mammographic examinations arising from an Australian population. Performance parameters including JAFROC, ROC, case sensitivity as well as specificity were compared between Australian and Singaporean readers using a Mann Whitney U test. Results: A significant difference (P=0.036) was demonstrated between the JAFROC scores of the Australian and Singaporean breast radiologists. No other significant differences were observed. Conclusion: JAFROC scores for Australian radiologists were higher than those obtained by the Singaporean counterparts. Whilst it is tempting to suggest this is down to reader expertise, this may be a simplistic explanation considering the very similar training and audit backgrounds of the two populations of radiologists. The influence of reading images that are different from those that radiologists normally encounter cannot be ruled out and requires further investigation, particularly in the light of increasing international outsourcing of radiologic reporting.

  20. Digital scrapbooking as a standard of care in neonatal intensive care units: initial experience.

    Science.gov (United States)

    Subhani, Muhammad T; Kanwal, Ifrah

    2012-01-01

    In this article, we describe a digital photo scrapbooking project as a standard of care for the parents of infants admitted in a neonatal intensive care unit (NICU). Photographs were taken from birth until discharge or expiry at special moments during the infant's hospitalization and used to create a digital scrapbook with daily notes by the parents. The scrapbook and original photos were provided on a CD at discharge or at expiry. Parents and their families unanimously appreciated the photos and the opportunity to record their thoughts, and considered the CDs as a lifetime treasure. Digital photo journaling could be implemented as a standard of care at other institutions with a commitment from the nursing and ancillary staff of the NICU and labor and delivery department, with possible support from volunteers.

  1. Radiologic-pathologic correlation of the mammographic findings retrospectively detected in inflammatory breast cancer. Usefulness in clinical practice

    International Nuclear Information System (INIS)

    Caumo, F.; Manfrin, E.; Bonetti, F.; Pinali, L.; Procacci, C.

    2002-01-01

    Background. The aim of this study was to describe the clinical, mammographical and pathological characteristics of inflammatory carcinoma. Patients and methods. Clinical, mammographical and histological sections of twenty-two women (age range 28-60 years) were reviewed. The examinations had been performed over a period of four years. Results. The clinical findings were: erythema, edema, thickening of the skin and breast heat in ten patients; palpable mass in nine patients; nipple discharge in one patient; absent in two patients. Pathological findings were: tumor emboli in the dermal lymphatics in eight patients; tumor emboli in the vessels in ten patients; tumor emboli both in the dermal lymphatics and in the vessels in four patients. The radiologic findings were: skin thickening, trabecular thickening and blurring of structure in ten patients (common presentation); mass in nine patients; malignant-type calcifications in two patients (uncommon presentation); absent in one patient. The follow-up examination (eighteen months) detected that only one patient with common presentation of inflammatory carcinoma had no local or systemic recurrence against eight patients with uncommon presentation. Conclusions. The clinical and mammographical aspects, which suggest the presence of an inflammatory carcinoma, occur only in 45.4% of the patients. The radiological aspect seems to correlate with the different prognosis of the tumour, resulting in a better prognosis in those with an uncommon aspect. (author)

  2. A novel and automatic mammographic texture resemblance marker is an independent risk factor for breast cancer

    DEFF Research Database (Denmark)

    Nielsen, Mads; Karemore, Gopal; Loog, Marco

    2011-01-01

    Objective: We investigated whether breast cancer is predicted by a breast cancer risk mammographic texture resemblance (MTR) marker. Methods: A previously published case-control study included 495 women of which 245 were diagnosed with breast cancer. In baseline mammograms, 2-4 years prior...... to diagnosis, the following mammographic parameters were analysed for relation to breast cancer risk: (C) categorical parenchymal pattern scores; (R) radiologist's percentage density, (P) computer-based percentage density; (H) computer-based breast cancer risk MTR marker; (E) computer-based hormone replacement...... treatment MTR marker; and (A) an aggregate of P and H. Results: Density scores, C, R, and P correlated (tau=0.3-0.6); no other pair of scores showed large (tau>0.2) correlation. For the parameters, the odds ratios of future incidence of breast cancer comparing highest to lowest categories (146 and 106...

  3. A new approach to develop computer-aided detection schemes of digital mammograms

    Science.gov (United States)

    Tan, Maxine; Qian, Wei; Pu, Jiantao; Liu, Hong; Zheng, Bin

    2015-06-01

    The purpose of this study is to develop a new global mammographic image feature analysis based computer-aided detection (CAD) scheme and evaluate its performance in detecting positive screening mammography examinations. A dataset that includes images acquired from 1896 full-field digital mammography (FFDM) screening examinations was used in this study. Among them, 812 cases were positive for cancer and 1084 were negative or benign. After segmenting the breast area, a computerized scheme was applied to compute 92 global mammographic tissue density based features on each of four mammograms of the craniocaudal (CC) and mediolateral oblique (MLO) views. After adding three existing popular risk factors (woman’s age, subjectively rated mammographic density, and family breast cancer history) into the initial feature pool, we applied a sequential forward floating selection feature selection algorithm to select relevant features from the bilateral CC and MLO view images separately. The selected CC and MLO view image features were used to train two artificial neural networks (ANNs). The results were then fused by a third ANN to build a two-stage classifier to predict the likelihood of the FFDM screening examination being positive. CAD performance was tested using a ten-fold cross-validation method. The computed area under the receiver operating characteristic curve was AUC = 0.779   ±   0.025 and the odds ratio monotonically increased from 1 to 31.55 as CAD-generated detection scores increased. The study demonstrated that this new global image feature based CAD scheme had a relatively higher discriminatory power to cue the FFDM examinations with high risk of being positive, which may provide a new CAD-cueing method to assist radiologists in reading and interpreting screening mammograms.

  4. Classification of mammographic masses using geometric symmetry and fractal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Guo Qi; Ruiz, V.F. [Cybernetics, School of Systems Engineering, Univ. of Reading (United Kingdom); Shao Jiaqing [Dept. of Electronics, Univ. of Kent (United Kingdom); Guo Falei [WanDe Industrial Engineering Co. (China)

    2007-06-15

    In this paper, we propose a fuzzy symmetry measure based on geometrical operations to characterise shape irregularity of mammographic mass lesion. Group theory, a powerful tool in the investigation of geometric transformation, is employed in our work to define and describe the underlying mathematical relations. We investigate the usefulness of fuzzy symmetry measure in combination with fractal analysis for classification of masses. Comparative studies show that fuzzy symmetry measure is useful for shape characterisation of mass lesions and is a good complementary feature for benign-versus-malignant classification of masses. (orig.)

  5. Force balancing in mammographic compression

    International Nuclear Information System (INIS)

    Branderhorst, W.; Groot, J. E. de; Lier, M. G. J. T. B. van; Grimbergen, C. A.; Neeter, L. M. F. H.; Heeten, G. J. den; Neeleman, C.

    2016-01-01

    Purpose: In mammography, the height of the image receptor is adjusted to the patient before compressing the breast. An inadequate height setting can result in an imbalance between the forces applied by the image receptor and the paddle, causing the clamped breast to be pushed up or down relative to the body during compression. This leads to unnecessary stretching of the skin and other tissues around the breast, which can make the imaging procedure more painful for the patient. The goal of this study was to implement a method to measure and minimize the force imbalance, and to assess its feasibility as an objective and reproducible method of setting the image receptor height. Methods: A trial was conducted consisting of 13 craniocaudal mammographic compressions on a silicone breast phantom, each with the image receptor positioned at a different height. The image receptor height was varied over a range of 12 cm. In each compression, the force exerted by the compression paddle was increased up to 140 N in steps of 10 N. In addition to the paddle force, the authors measured the force exerted by the image receptor and the reaction force exerted on the patient body by the ground. The trial was repeated 8 times, with the phantom remounted at a slightly different orientation and position between the trials. Results: For a given paddle force, the obtained results showed that there is always exactly one image receptor height that leads to a balance of the forces on the breast. For the breast phantom, deviating from this specific height increased the force imbalance by 9.4 ± 1.9 N/cm (6.7%) for 140 N paddle force, and by 7.1 ± 1.6 N/cm (17.8%) for 40 N paddle force. The results also show that in situations where the force exerted by the image receptor is not measured, the craniocaudal force imbalance can still be determined by positioning the patient on a weighing scale and observing the changes in displayed weight during the procedure. Conclusions: In mammographic breast

  6. Multilingual Literacies in Transnational Digitally Mediated Contexts: An Exploratory Study of Immigrant Teens in the United States

    Science.gov (United States)

    Lam, Wan Shun Eva; Rosario-Ramos, Enid

    2009-01-01

    This study explores the literacy practices that are involved in transnational social and information networking among youths of immigrant backgrounds in the United States. In particular, it investigates the ways in which young migrants of diverse national origins in the United States are utilising digital media to organise social relationships…

  7. Barriers and facillitators to compliance with routine mammographic screening

    International Nuclear Information System (INIS)

    Kessler, H.B.; Rimer, B.; Keintz, M.K.; Myers, R.E.; Engstrom, P.F.

    1988-01-01

    Six hundred one randomly selected women were interviewed to determine their reasons for compliance or noncompliance with free HMO-sponsored mammographic examinations. Noncompliers were significantly more likely to believe mammograms are unnecessary without symptoms, too much trouble, or inconvenient and to perceive their physicians as not recommending mammograms. Compliers were more likely to believe that early breast cancer can be cured and to recognize that breast screening is for asymptomatic individuals. When cost is eliminated as a barrier to screening, a variety of socioeconomic, psychological, and access barriers are exposed. Radiologists must be cognizant of these factors in planning and participating in breast cancer screening programs

  8. Birth weight, childhood body mass index, and height in relation to mammographic density and breast cancer

    DEFF Research Database (Denmark)

    Andersen, Zorana Jovanovic; Baker, Jennifer Lyn; Bihrmann, Kristine

    2014-01-01

    High breast density, a strong predictor of breast cancer may be determined early in life. Childhood anthropometric factors have been related to breast cancer and breast density, but rarely simultaneously. We examined whether mammographic density (MD) mediates an association of birth weight, child...

  9. Immediate and delayed effects of mammographic screening on breast cancer mortality and incidence in birth cohorts

    NARCIS (Netherlands)

    Ripping, T. M.; Verbeek, A. L. M.; van der Waal, D.; Otten, J. D. M.; den Heeten, G. J.; Fracheboud, J.; de Koning, H. J.; Broeders, M. J. M.

    2013-01-01

    Trend studies investigating the impact of mammographic screening usually display age-specific mortality and incidence rates over time, resulting in an underestimate of the benefit of screening, that is, mortality reduction, and an overestimate of its major harmful effect, that is, overdiagnosis.

  10. Immediate and delayed effects of mammographic screening on breast cancer mortality and incidence in birth cohorts

    NARCIS (Netherlands)

    Ripping, T.M.; Verbeek, A.L.M.; Waal, D. van der; Otten, J.D.M.; Heeten, G.J. den; Fracheboud, J.; Koning, H.J. de; Broeders, M.J.M.

    2013-01-01

    Background:Trend studies investigating the impact of mammographic screening usually display age-specific mortality and incidence rates over time, resulting in an underestimate of the benefit of screening, that is, mortality reduction, and an overestimate of its major harmful effect, that is,

  11. Possible effects of insulin-like growth factor-I, IGF-binding protein-3 and IGF-1/IGFBP-3 molar ratio on mammographic density: a cross-sectional study.

    Science.gov (United States)

    Meggiorini, M L; Cipolla, V; Borgoni, G; Nofroni, I; Pala, A; de Felice, C

    2012-01-01

    The purpose of this study was to examine the possible effects of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio on mammographic density and assess whether this relationship was similar in subgroups of pre- and postmenopausal women. A group of 341 Italian women of childbearing age or naturally postmenopausal who had performed mammographic examination at the section of radiology of our department a maximum three months prior to recruitment were enrolled. A blood sample was drawn for determination of IGF-1, IGFBP-3 levels and IGF-1/IGFBP-3 molar ratio was calculated. On the basis of recent mammograms the women were divided into two groups: dense breast (DB) and non-dense breast (NDB). To assess the association between mammographic density and IGF-1, IGFBP-3 and Molar ratio Student's t-test was employed before and after stratified by menopausal status. The analysis of the relationship between mammographic density and plasma levels of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio showed that IGF-1 levels and molar ratio varied in the two groups resulting in higher mean values in the DB group whereas IGFBP-3 showed similar values in both groups (DB and NDB). After stratification of the study population by menopausal status, no association was found. Our study provides strong evidence of a crude association between breast density, and plasma levels of IGF-1 and molar ratio. IGF-1 and molar ratio might increase mammographic density and thus the risk of developing breast cancer.

  12. Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

    International Nuclear Information System (INIS)

    Ikejimba, Lynda C.; Kontos, Despina; Maidment, Andrew D. A.

    2010-01-01

    Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm 3 were segmented from the DBT images and corresponding 2.5 cm 2 ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p 2 = 0.39) compared to DM (R 2 = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

  13. 1:250,000-scale Hydrologic Units of the United States

    Science.gov (United States)

    Steeves, Peter; Nebert, Douglas

    1994-01-01

    The Geographic Information Retrieval and Analysis System (GIRAS) was developed in the mid 70s to put into digital form a numberof data layers which were of interest to the USGS. One of these data layers was the Hydrologic Units. The map is based on the Hydrologic Unit Maps published by the U.S. Geological Survey Office of Water Data Coordination, together with the list descriptions and name of region, subregion, accounting units, and cataloging unit. The hydrologic units are encoded with an eight-digit number that indicates the hydrologic region (first two digits), hydrologic subregion (second two digits), accounting unit (third two digits), and cataloging unit (fourth two digits). The data produced by GIRAS was originally collected at a scale of 1:250K. Some areas, notably major cities in the west, were recompiled at a scale of 1:100K. In order to join the data together and use the data in a geographic information system (GIS) the data were processed in the ARC/INFO GUS software package. Within the GIS, the data were edgematched and the neatline boundaries between maps were removed to create a single data set for the conterminous

  14. Evaluation of mammographic density patterns: reproducibility and concordance among scales

    Directory of Open Access Journals (Sweden)

    Garrido-Estepa Macarena

    2010-09-01

    Full Text Available Abstract Background Increased mammographic breast density is a moderate risk factor for breast cancer. Different scales have been proposed for classifying mammographic density. This study sought to assess intra-rater agreement for the most widely used scales (Wolfe, Tabár, BI-RADS and Boyd and compare them in terms of classifying mammograms as high- or low-density. Methods The study covered 3572 mammograms drawn from women included in the DDM-Spain study, carried-out in seven Spanish Autonomous Regions. Each mammogram was read by an expert radiologist and classified using the Wolfe, Tabár, BI-RADS and Boyd scales. In addition, 375 mammograms randomly selected were read a second time to estimate intra-rater agreement for each scale using the kappa statistic. Owing to the ordinal nature of the scales, weighted kappa was computed. The entire set of mammograms (3572 was used to calculate agreement among the different scales in classifying high/low-density patterns, with the kappa statistic being computed on a pair-wise basis. High density was defined as follows: percentage of dense tissue greater than 50% for the Boyd, "heterogeneously dense and extremely dense" categories for the BI-RADS, categories P2 and DY for the Wolfe, and categories IV and V for the Tabár scales. Results There was good agreement between the first and second reading, with weighted kappa values of 0.84 for Wolfe, 0.71 for Tabár, 0.90 for BI-RADS, and 0.92 for Boyd scale. Furthermore, there was substantial agreement among the different scales in classifying high- versus low-density patterns. Agreement was almost perfect between the quantitative scales, Boyd and BI-RADS, and good for those based on the observed pattern, i.e., Tabár and Wolfe (kappa 0.81. Agreement was lower when comparing a pattern-based (Wolfe or Tabár versus a quantitative-based (BI-RADS or Boyd scale. Moreover, the Wolfe and Tabár scales classified more mammograms in the high-risk group, 46.61 and 37

  15. A fully-automated software pipeline for integrating breast density and parenchymal texture analysis for digital mammograms: parameter optimization in a case-control breast cancer risk assessment study

    Science.gov (United States)

    Zheng, Yuanjie; Wang, Yan; Keller, Brad M.; Conant, Emily; Gee, James C.; Kontos, Despina

    2013-02-01

    Estimating a woman's risk of breast cancer is becoming increasingly important in clinical practice. Mammographic density, estimated as the percent of dense (PD) tissue area within the breast, has been shown to be a strong risk factor. Studies also support a relationship between mammographic texture and breast cancer risk. We have developed a fullyautomated software pipeline for computerized analysis of digital mammography parenchymal patterns by quantitatively measuring both breast density and texture properties. Our pipeline combines advanced computer algorithms of pattern recognition, computer vision, and machine learning and offers a standardized tool for breast cancer risk assessment studies. Different from many existing methods performing parenchymal texture analysis within specific breast subregions, our pipeline extracts texture descriptors for points on a spatial regular lattice and from a surrounding window of each lattice point, to characterize the local mammographic appearance throughout the whole breast. To demonstrate the utility of our pipeline, and optimize its parameters, we perform a case-control study by retrospectively analyzing a total of 472 digital mammography studies. Specifically, we investigate the window size, which is a lattice related parameter, and compare the performance of texture features to that of breast PD in classifying case-control status. Our results suggest that different window sizes may be optimal for raw (12.7mm2) versus vendor post-processed images (6.3mm2). We also show that the combination of PD and texture features outperforms PD alone. The improvement is significant (p=0.03) when raw images and window size of 12.7mm2 are used, having an ROC AUC of 0.66. The combination of PD and our texture features computed from post-processed images with a window size of 6.3 mm2 achieves an ROC AUC of 0.75.

  16. Introduction: Philosophers of the World Unite! Theorising Digital Labour and Virtual Work—Definitions, Dimensions, and Forms

    Directory of Open Access Journals (Sweden)

    Marisol Sandoval

    2014-09-01

    Full Text Available In 1845, Karl Marx (1845, 571 formulated the 11th Feuerbach Thesis: “The philosophers have only interpreted the world in various ways; the point is to change it.” Today, interpreting the world has become an important form of labour that is expressed on and with the help of digital media. In this context it has become common to talk about digital labour and virtual work. Yet the changes that digital, social, and mobile media bring about in the world of labour and work have thus far only been little theoretically interpreted. In order to change the information society for the better, we first have to interpret digital labour with the help of critical theories. Social theorists of the world from different fields, backgrounds, interdisciplines, transdisciplines, and disciplines have to unite for this collective philosophical task. This special issue of tripleC: Communication, Capitalism & Critique aims to contribute to building a theoretical framework for the critical analysis of digital labour, virtual work, and related concepts that can initiate further debates, inform empirical studies, and inspire social struggles connected to work and labour in and beyond digital capitalism. The papers collected in this special issue (a provide systematic definitions of digital labour, (b analyse its specific dimension, and (c discuss different forms of digital labour.

  17. [Digital luminescence radiography. A new method of study in thoracic diagnosis at the intensive care unit].

    Science.gov (United States)

    Witte, G; Pothmann, W; Bause, H; Nicolas, V; Schulte am Esch, J; Bücheler, E

    1989-02-01

    The digital luminescence-radiography (DLR) technique relies on a complete digitalization of the X-ray image. Luminescence crystals on the imaging plate serve as an energy reservoir following their exposure to ionized radiation from any conventional X-ray source. A Helium-Neon laser stimulates the electrons in their high energy bands and therefore will be dropped back emitting luminescence. This luminescence is digitized by the DLR-System thus delivering a complete digital image to the image processor for subsequent processing and evaluation. The processed digital image is then recorded on a conventional film or a monitor screen. More than 3000 chest examinations using DLR have been performed on intensive care unit (ICU) patients at the University Hospital Eppendorf following the first eleven months since the clinical introduction of this new technique. The positive aspects of DLR such as high-contrast resolution and optimal reproducibility were clinically evaluated under ICU conditions. It was shown that DLR greatly improves the quality of the chest X-rays of all ICU patients and offers the following advantages: reproducibility, lateral chest projection, no insufficient exposure, reduction of exposure dose, electronical post-processing and storage, quality preserving digital storage and copying.

  18. Mammographic features and subsequent risk of breast cancer: a comparison of qualitative and quantitative evaluations in the Guernsey prospective studies.

    Science.gov (United States)

    Torres-Mejía, Gabriela; De Stavola, Bianca; Allen, Diane S; Pérez-Gavilán, Juan J; Ferreira, Jorge M; Fentiman, Ian S; Dos Santos Silva, Isabel

    2005-05-01

    Mammographic features are known to be associated with breast cancer but the magnitude of the effect differs markedly from study to study. Methods to assess mammographic features range from subjective qualitative classifications to computer-automated quantitative measures. We used data from the UK Guernsey prospective studies to examine the relative value of these methods in predicting breast cancer risk. In all, 3,211 women ages > or =35 years who had a mammogram taken in 1986 to 1989 were followed-up to the end of October 2003, with 111 developing breast cancer during this period. Mammograms were classified using the subjective qualitative Wolfe classification and several quantitative mammographic features measured using computer-based techniques. Breast cancer risk was positively associated with high-grade Wolfe classification, percent breast density and area of dense tissue, and negatively associated with area of lucent tissue, fractal dimension, and lacunarity. Inclusion of the quantitative measures in the same model identified area of dense tissue and lacunarity as the best predictors of breast cancer, with risk increasing by 59% [95% confidence interval (95% CI), 29-94%] per SD increase in total area of dense tissue but declining by 39% (95% CI, 53-22%) per SD increase in lacunarity, after adjusting for each other and for other confounders. Comparison of models that included both the qualitative Wolfe classification and these two quantitative measures to models that included either the qualitative or the two quantitative variables showed that they all made significant contributions to prediction of breast cancer risk. These findings indicate that breast cancer risk is affected not only by the amount of mammographic density but also by the degree of heterogeneity of the parenchymal pattern and, presumably, by other features captured by the Wolfe classification.

  19. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  20. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  1. From a mammographic station to a federal mammalogic center

    International Nuclear Information System (INIS)

    Rozhkova, N.I.; Kharchenko, V.P.

    2000-01-01

    Using the history of mammalogy development in Russian Scientific Center of Roentgenoradiology of the Ministry of Public Health of Russian Federation as an example the evolution of above trend in Russia is retraced. It is shown that during 20 years (from 1978) in the department of mammary gland diseases diagnosis of the Centre the rational, economically expedient and highly efficient diagnostic system for combined examination of mammary glands is developing and introducing in medical prophylactic installations of Russian Federation. This system consists of women selection for risk group, stage of additional examination in special mammographic rooms and therapeutic stage. Directions of researches of the Centre (technical, organizational-methodical, medical) are considered [ru

  2. Results of conservative surgery and radiation for mammographically detected ductal carcinoma in situ (DCIS)

    International Nuclear Information System (INIS)

    Fowble, B.; Hanlon, A.L.; Fein, D.A.; Hoffman, J.P.; Sigurdson, E.R.; Patchefsky, A.; Kessler, H.

    1996-01-01

    Purpose: The role of conservative surgery and radiation for mammographically detected DCIS is controversial. In particular, there is a paucity of data for outcome with radiation in a group of patients comparable to those treated with local excision and surveillance (mammographically detected DCIS ≤2.5 cm, negative resection margins, negative post-biopsy mammogram). The purpose of this study is to report long term outcome of conservative surgery and radiation for mammographically detected DCIS with emphasis on the results in patients (pts.) considered candidates for excision alone. Materials and Methods: From 1983 to 1992, 110 women with mammographically detected DCIS (calcifications 72%, mass ± calcifications 27%) and no prior history of breast cancer underwent needle localization biopsy followed by radiation. The median age of the patient population was 56 yrs. (range 37-81). The median followup was 5.3 yrs. (range .5-12). Re-excision was performed in 55%. Final margins of resection were negative in 62%, positive 7%, close 11%, and unknown 20%. Axillary dissection was performed in 31 pts. and all had negative nodes. 31% had a positive family history of breast cancer (1 affected relative-25 pts., two-7 pts., three-2 pts.). The most common predominant histologic subtype was comedo (54%) followed by cribriform (22%). The median pathologic tumor size was 8 mm (range 2 mm to 5 cm). A post-biopsy mammogram prior to radiation was performed in 46% of the patients. Radiation consisted of treatment to the entire breast (median 5000 cGy) with a boost to the primary site (97%) of an additional 1000 cGy. The median total dose to the primary site was 6040 cGy (range 5000 to 6660). Results: Three patients developed a recurrence in the treated breast at 52, 106, and 107 months. All 3 recurrences were invasive ductal cancers and all were treated with mastectomy. The location of the recurrence was in the same quadrant as the primary in 1 pt. and in a separate quadrant in 2 pts

  3. EnviroAtlas - Annual average potential wind energy resource by 12-digit HUC for the Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset shows the annual average potential wind energy resource in kilowatt hours per square kilometer per day for each 12-digit Hydrologic Unit...

  4. Identification of a novel percent mammographic density locus at 12q24.

    Science.gov (United States)

    Stevens, Kristen N; Lindstrom, Sara; Scott, Christopher G; Thompson, Deborah; Sellers, Thomas A; Wang, Xianshu; Wang, Alice; Atkinson, Elizabeth; Rider, David N; Eckel-Passow, Jeanette E; Varghese, Jajini S; Audley, Tina; Brown, Judith; Leyland, Jean; Luben, Robert N; Warren, Ruth M L; Loos, Ruth J F; Wareham, Nicholas J; Li, Jingmei; Hall, Per; Liu, Jianjun; Eriksson, Louise; Czene, Kamila; Olson, Janet E; Pankratz, V Shane; Fredericksen, Zachary; Diasio, Robert B; Lee, Adam M; Heit, John A; DeAndrade, Mariza; Goode, Ellen L; Vierkant, Robert A; Cunningham, Julie M; Armasu, Sebastian M; Weinshilboum, Richard; Fridley, Brooke L; Batzler, Anthony; Ingle, James N; Boyd, Norman F; Paterson, Andrew D; Rommens, Johanna; Martin, Lisa J; Hopper, John L; Southey, Melissa C; Stone, Jennifer; Apicella, Carmel; Kraft, Peter; Hankinson, Susan E; Hazra, Aditi; Hunter, David J; Easton, Douglas F; Couch, Fergus J; Tamimi, Rulla M; Vachon, Celine M

    2012-07-15

    Percent mammographic density adjusted for age and body mass index (BMI) is one of the strongest risk factors for breast cancer and has a heritable component that remains largely unidentified. We performed a three-stage genome-wide association study (GWAS) of percent mammographic density to identify novel genetic loci associated with this trait. In stage 1, we combined three GWASs of percent density comprised of 1241 women from studies at the Mayo Clinic and identified the top 48 loci (99 single nucleotide polymorphisms). We attempted replication of these loci in 7018 women from seven additional studies (stage 2). The meta-analysis of stage 1 and 2 data identified a novel locus, rs1265507 on 12q24, associated with percent density, adjusting for age and BMI (P = 4.43 × 10(-8)). We refined the 12q24 locus with 459 additional variants (stage 3) in a combined analysis of all three stages (n = 10 377) and confirmed that rs1265507 has the strongest association in the 12q24 region (P = 1.03 × 10(-8)). Rs1265507 is located between the genes TBX5 and TBX3, which are members of the phylogenetically conserved T-box gene family and encode transcription factors involved in developmental regulation. Understanding the mechanism underlying this association will provide insight into the genetics of breast tissue composition.

  5. Studies Comparing Screen-Film Mammography and Full-Field Digital Mammography in Breast Cancer Screening: Updated Review

    International Nuclear Information System (INIS)

    Skaane, P.

    2009-01-01

    Full-field digital mammography (FFDM) has several potential benefits as compared with screen-film mammography (SFM) in mammography screening. Digital technology also opens for implementation of advanced applications, including computer-aided detection (CAD) and tomosynthesis. Phantom studies and experimental clinical studies have shown that FFDM is equal or slightly superior to SFM for detection and characterization of mammographic abnormalities. Despite obvious advantages, the conversion to digital mammography has been slower than anticipated, and not only due to higher costs. Until very recently, some countries did not even permit the use of digital mammography in breast cancer screening. The reason for this reluctant attitude was concern about lower spatial resolution and about using soft-copy reading. Furthermore, there was a lack of data supporting improved diagnostic accuracy using FFDM in a screening setting, since two pioneer trials both showed nonsignificantly lower cancer detection rate at FFDM. The 10 studies comparing FFDM and SFM in mammography screening published so far have shown divergent and rather conflicting results. Nevertheless, there is a rapid conversion to digital mammography in breast cancer screening in many western countries. The aim of this article is to give an updated review of these studies, discuss the conflicting findings, and draw some conclusions from the results

  6. Mammographic Density Reduction as a Prognostic Marker for Postmenopausal Breast Cancer: Results Using a Joint Longitudinal-Survival Modeling Approach.

    Science.gov (United States)

    Andersson, Therese M-L; Crowther, Michael J; Czene, Kamila; Hall, Per; Humphreys, Keith

    2017-11-01

    Previous studies have linked reductions in mammographic density after a breast cancer diagnosis to an improved prognosis. These studies focused on short-term change, using a 2-stage process, treating estimated change as a fixed covariate in a survival model. We propose the use of a joint longitudinal-survival model. This enables us to model long-term trends in density while accounting for dropout as well as for measurement error. We studied the change in mammographic density after a breast cancer diagnosis and its association with prognosis (measured by cause-specific mortality), overall and with respect to hormone replacement therapy and tamoxifen treatment. We included 1,740 women aged 50-74 years, diagnosed with breast cancer in Sweden during 1993-1995, with follow-up until 2008. They had a total of 6,317 mammographic density measures available from the first 5 years of follow-up, including baseline measures. We found that the impact of the withdrawal of hormone replacement therapy on density reduction was larger than that of tamoxifen treatment. Unlike previous studies, we found that there was an association between density reduction and survival, both for tamoxifen-treated women and women who were not treated with tamoxifen. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.

  7. Improvement of Breast Cancer Detection Using Non-subsampled Contourlet Transform and Super-Resolution Technique in Mammographic Images

    Directory of Open Access Journals (Sweden)

    Fatemeh Pak

    2015-05-01

    Full Text Available Introduction Breast cancer is one of the most life-threatening conditions among women. Early detection of this disease is the only way to reduce the associated mortality rate. Mammography is a standard method for the early detection of breast cancer. Today, considering the importance of breast cancer detection, computer-aided detection techniques have been employed to increase the quality of mammographic images and help physicians reduce false positive rate (FPR. Materials and Methods In this study, a method was proposed for improving the quality of mammographic images to help radiologists establish a prompt and accurate diagnosis. The proposed approach included three major parts including pre-processing, feature extraction, and classification. In the pre-processing stage, the region of interest was determined and the image quality was improved by non-subsampled contourlet transform and super-resolution algorithm. In the feature extraction stage, some features of image components were extracted and skewness of each feature was calculated. Finally, a support vector machine was utilized to classify the features and determine the probability of benignity or malignancy of the disease. Results Based on the obtained results using Mammographic Image Analysis Society (MIAS database, the mean accuracy was estimated at 87.26% and maximum accuracy was 96.29%. Also, the mean and minimum FPRs were estimated at 9.55% and 2.87%, respectively.     Conclusion The results obtained using MIAS database indicated the superiority of the proposed method to other techniques. The reduced FPR in the proposed method was a significant finding in the present article.

  8. Impact of errors in recorded compressed breast thickness measurements on volumetric density classification using volpara v1.5.0 software.

    Science.gov (United States)

    Waade, Gunvor Gipling; Highnam, Ralph; Hauge, Ingrid H R; McEntee, Mark F; Hofvind, Solveig; Denton, Erika; Kelly, Judith; Sarwar, Jasmine J; Hogg, Peter

    2016-06-01

    Mammographic density has been demonstrated to predict breast cancer risk. It has been proposed that it could be used for stratifying screening pathways and recommending additional imaging. Volumetric density tools use the recorded compressed breast thickness (CBT) of the breast measured at the x-ray unit in their calculation; however, the accuracy of the recorded thickness can vary. The aim of this study was to investigate whether inaccuracies in recorded CBT impact upon volumetric density classification and to examine whether the current quality control (QC) standard is sufficient for assessing mammographic density. Raw data from 52 digital screening mammograms were included in the study. For each image, the clinically recorded CBT was artificially increased and decreased in increments of 1 mm to simulate measurement error, until ±15% from the recorded CBT was reached. New images were created for each 1 mm step in thickness resulting in a total of 974 images which then had volpara density grade (VDG) and volumetric density percentage assigned. A change in VDG was observed in 38.5% (n = 20) of mammograms when applying ±15% error to the recorded CBT and 11.5% (n = 6) was within the QC standard prescribed error of ±5 mm. The current QC standard of ±5 mm error in recorded CBT creates the potential for error in mammographic density measurement. This may lead to inaccurate classification of mammographic density. The current QC standard for assessing mammographic density should be reconsidered.

  9. Using tumor phenotype, histological tumor distribution, and mammographic appearance to explain the survival differences between screen-detected and clinically detected breast cancers.

    Science.gov (United States)

    Chuang, Shu-Lin; Chen, Sam Li-Sheng; Yu, Cheng-Ping; Chang, King-Jen; Yen, Amy Ming-Fang; Chiu, Sherry Yueh-Hsia; Fann, Jean Ching-Yuan; Tabár, László; Stephen, Duffy W; Smith, Robert A; Chen, Hsiu-Hsi

    2014-08-01

    In the era of mass screening for breast cancer with mammography, it has been noted that conventional tumor attributes and mammographic appearance are insufficient to account for the better prognosis of screen-detected tumors. Such prognostication may require additional updated pathological information regarding tumor phenotype (e.g., basal status) and histological tumor distribution (focality). We investigated this hypothesis using a Bayesian approach to analyze breast cancer data from Dalarna County, Sweden. We used data for tumors diagnosed in the Swedish Two-County Trial and early service screening period, 1977-1995, and from the mature service screening period, 1996-1998. In the early period of mammographic screening (1977-1995), the crude hazard ratio (HR) of breast cancer death for screen-detected cases compared with symptomatic ones was 0.22 (95% CI: 0.17-0.29) compared with 0.53 (95% CI: 0.34-0.76) when adjusted for conventional tumor attributes only. Using the data from the mature service screening period, 1996-1998, the HR was 0.23 (95% CI: 0.08-0.44) unadjusted and 0.71 (95% CI: 0.26-1.47) after adjustment for tumor phenotype, mammographic appearance, histological tumor distribution, and conventional tumor attributes. The area under the ROC curve (AUC) for the prediction of breast cancer deaths using these variables without the detection mode was 0.82, only slightly less than that observed when additionally including the detection mode (AUC=0.83). Using Freedman statistics, conventional tumor attributes and mammographic appearances explained 58% (95% CI: 57.5-58.6%) of the difference of breast cancer survival between the screen-detected and the clinically detected breast cancers, whereas the corresponding figure was increased to 77% (95% CI: 75.6-77.6%) when adding the two information on tumor phenotype and histological tumor distribution. The results indicated that conventional tumor attributes and mammographic appearance are not sufficient to be

  10. External validation of a publicly available computer assisted diagnostic tool for mammographic mass lesions with two high prevalence research datasets.

    Science.gov (United States)

    Benndorf, Matthias; Burnside, Elizabeth S; Herda, Christoph; Langer, Mathias; Kotter, Elmar

    2015-08-01

    Lesions detected at mammography are described with a highly standardized terminology: the breast imaging-reporting and data system (BI-RADS) lexicon. Up to now, no validated semantic computer assisted classification algorithm exists to interactively link combinations of morphological descriptors from the lexicon to a probabilistic risk estimate of malignancy. The authors therefore aim at the external validation of the mammographic mass diagnosis (MMassDx) algorithm. A classification algorithm like MMassDx must perform well in a variety of clinical circumstances and in datasets that were not used to generate the algorithm in order to ultimately become accepted in clinical routine. The MMassDx algorithm uses a naïve Bayes network and calculates post-test probabilities of malignancy based on two distinct sets of variables, (a) BI-RADS descriptors and age ("descriptor model") and (b) BI-RADS descriptors, age, and BI-RADS assessment categories ("inclusive model"). The authors evaluate both the MMassDx (descriptor) and MMassDx (inclusive) models using two large publicly available datasets of mammographic mass lesions: the digital database for screening mammography (DDSM) dataset, which contains two subsets from the same examinations-a medio-lateral oblique (MLO) view and cranio-caudal (CC) view dataset-and the mammographic mass (MM) dataset. The DDSM contains 1220 mass lesions and the MM dataset contains 961 mass lesions. The authors evaluate discriminative performance using area under the receiver-operating-characteristic curve (AUC) and compare this to the BI-RADS assessment categories alone (i.e., the clinical performance) using the DeLong method. The authors also evaluate whether assigned probabilistic risk estimates reflect the lesions' true risk of malignancy using calibration curves. The authors demonstrate that the MMassDx algorithms show good discriminatory performance. AUC for the MMassDx (descriptor) model in the DDSM data is 0.876/0.895 (MLO/CC view) and AUC

  11. Automated mammographic breast density estimation using a fully convolutional network.

    Science.gov (United States)

    Lee, Juhun; Nishikawa, Robert M

    2018-03-01

    The purpose of this study was to develop a fully automated algorithm for mammographic breast density estimation using deep learning. Our algorithm used a fully convolutional network, which is a deep learning framework for image segmentation, to segment both the breast and the dense fibroglandular areas on mammographic images. Using the segmented breast and dense areas, our algorithm computed the breast percent density (PD), which is the faction of dense area in a breast. Our dataset included full-field digital screening mammograms of 604 women, which included 1208 mediolateral oblique (MLO) and 1208 craniocaudal (CC) views. We allocated 455, 58, and 91 of 604 women and their exams into training, testing, and validation datasets, respectively. We established ground truth for the breast and the dense fibroglandular areas via manual segmentation and segmentation using a simple thresholding based on BI-RADS density assessments by radiologists, respectively. Using the mammograms and ground truth, we fine-tuned a pretrained deep learning network to train the network to segment both the breast and the fibroglandular areas. Using the validation dataset, we evaluated the performance of the proposed algorithm against radiologists' BI-RADS density assessments. Specifically, we conducted a correlation analysis between a BI-RADS density assessment of a given breast and its corresponding PD estimate by the proposed algorithm. In addition, we evaluated our algorithm in terms of its ability to classify the BI-RADS density using PD estimates, and its ability to provide consistent PD estimates for the left and the right breast and the MLO and CC views of the same women. To show the effectiveness of our algorithm, we compared the performance of our algorithm against a state of the art algorithm, laboratory for individualized breast radiodensity assessment (LIBRA). The PD estimated by our algorithm correlated well with BI-RADS density ratings by radiologists. Pearson's rho values of

  12. Evaluation of mammographic screen-film combinations in the clinic

    International Nuclear Information System (INIS)

    Shepard, J.

    1987-01-01

    Six commercially available mammographic film-screen combinations were evaluated in the authors department. Film speed and contrast was measured by obtaining H and D curves. Sensitivity to processing conditions was determined by analyzing changes in the H and D cures as a function of development time and temperature and by examining artifacts in a uniformly exposed film. Radiographs of a 0.5 0 star pattern show relative screen unsharpness. The speed of the film-screen combination is indicated by calculating patient dose necessary to produce optical densities of 1.5 through phantom thicknesses of 3.5 cm of acrylic. Images of a modified RMI detail phantom obtained with each film-screen combination were evaluated by 22 radiologist. Results indicate the physicians' overall preference

  13. Diagnostic imaging of lobular carcinoma of the breast. Mammographic, US and MR findings

    International Nuclear Information System (INIS)

    Bazzocchi, M.; Facecchia, I.; Zuiani, C.; Smania, S.; Puglisi, F.; Di Loreto, C.

    2000-01-01

    Purpose of this article is to evaluate the most frequent mammographic, US and MR findings of invasive lobular carcinoma and the role of MRI in defining multifocality and/or multi centricity of this tumor histotype. 45 lobular carcinomas in 39 patients were studied and selected from 421 breast cancers. Core biopsy with a 14G needle was performed in 39 cases, under US guidance in 36/39 and under mammographic guidance in 3/39 cases. Surgical biopsy was performed in 2 cases and the diagnosis could be made only after mastectomy in 5 cases. All patients were examined with mammography and US and (10-13 MHz) and 8 also with MRI. 28/46 palpable lesions (60.9%). Core biopsy correctly diagnosed 38/39 lesions (97.4%). The most frequent mammographic findings was that of a nodular opacity without microcalcifications (34.8%), followed by a mass with spiculate d borders (30.4%). Microcalcifications were seen in one case only (2.2%). Mammography detected no abnormalities in 15.2% of cases, but US showed a lesion in 2 of these cases. The most frequent US pattern was that of a hypoechoic lesion (43.5%), followed by posterior US beam attenuation. No US signs of abnormality were seen 15.2%. MRI correctly detected 13 lesions. Contrast enhancement was greater than 70% at one minute in 10 cases and greater than 40% in one case; two lesions exhibited atypical slow contrast enhancement, peaking at 5 minutes. MRI detected 5 lesions missed both mammography and US and showed multifocal (3 and 2) lesions where the other techniques had detected one lesion only. At mammography and US invasive lobular carcinoma exhibits no different features than ductal carcinoma but is difficult to identify especially in its early stages. US is a useful tool especially to characterize mammography-detected lesions but in the experience it also demonstrated 2 lesions missed at mammography. MRI is a precious examination to define the multifocal, multi centric or bilateral character of invasive lobular carcinoma

  14. Evaluation of the quality of CR mammography images in Chugoku Rosai Hospital. Visual evaluation and digital evaluation

    International Nuclear Information System (INIS)

    Makihata, Hiroshi; Fukuda, Tomoya; Aomori, Masaji; Hara, Shinji

    2005-01-01

    New mammography system (50-micrometer system) composed of Fuji computed tomography (FCR) both sides IP, 5000MA and dry imager was introduced in the Department of Physical Checkup of Chugoku Rosai Hospital in 2003. We performed visual evaluation and digital evaluation using 50-micrometer system in accordance with (the quality control guidance of) Non-Profit Organization the Central Committee on Quality Control of Mammographic Screening. In visual evaluation using RMI156 phantom the system cleared the quality control guidance about a fiber, calcification, and masses. On step phantom, it passed about 10 steps, masses, and calcifications. Since a success standard was not announced officially, the performance in digital evaluation cannot be judged and only the result is presented. In digital evaluation, signal-to-noise ratio (SNR) is 14.9, root of mean squares (RMS) is 32.9, SNRC is 16.4, SNRT is 3.65. This system image has high sharpness and is considered from the result in visual evaluation to have the ability of offering images with a high degree of information. (author)

  15. Mammographic density and breast cancer risk by family history in women of white and Asian ancestry.

    Science.gov (United States)

    Maskarinec, Gertraud; Nakamura, Kaylae L; Woolcott, Christy G; Conroy, Shannon M; Byrne, Celia; Nagata, Chisato; Ursin, Giske; Vachon, Celine M

    2015-04-01

    Mammographic density, i.e., the radiographic appearance of the breast, is a strong predictor of breast cancer risk. To determine whether the association of breast density with breast cancer is modified by a first-degree family history of breast cancer (FHBC) in women of white and Asian ancestry, we analyzed data from four case-control studies conducted in the USA and Japan. The study population included 1,699 breast cancer cases and 2,422 controls, of whom 45% reported white (N = 1,849) and 40% Asian (N = 1,633) ancestry. To standardize mammographic density assessment, a single observer re-read all mammograms using one type of interactive thresholding software. Logistic regression was applied to estimate odds ratios (OR) while adjusting for confounders. Overall, 496 (12%) of participants reported a FHBC, which was significantly associated with breast cancer risk in the adjusted model (OR 1.51; 95% CI 1.23-1.84). There was a statistically significant interaction on a multiplicative scale between FHBC and continuous percent density (per 10 % density: p = 0.03). The OR per 10% increase in percent density was higher among women with a FHBC (OR 1.30; 95% CI 1.13-1.49) than among those without a FHBC (OR 1.14; 1.09-1.20). This pattern was apparent in whites and Asians. The respective ORs were 1.45 (95% CI 1.17-1.80) versus 1.22 (95% CI 1.14-1.32) in whites, whereas the values in Asians were only 1.24 (95% CI 0.97-1.58) versus 1.09 (95% CI 1.00-1.19). These findings support the hypothesis that women with a FHBC appear to have a higher risk of breast cancer associated with percent mammographic density than women without a FHBC.

  16. Mammographic breast density in recent and longer-standing ethiopian immigrants to israel.

    Science.gov (United States)

    Sklair-Levy, Miri; Segev, Anat; Sella, Tamar; Calderon-Margalit, Ronit; Zippel, Douglas

    2018-04-23

    High breast density is associated with an increased risk of breast cancer development. Little is known concerning ethnic variations in breast density and its relevant contributing factors. We aimed to study breast density among Ethiopian immigrants to Israel in comparison with Israeli-born women and to determine any effect on breast density of the length of residency in the immigrant population. Mammographic breast density using the BI-RADS system was estimated and compared between 77 women of Ethiopian origin who live in Israel and 177 Israeli-born controls. Logistic regression analysis was performed to estimate the odds ratios (OR) for high density (BI-RADS score ≥ 3) vs low density (BI-RADS score density compared with Israeli-born women. Adjustments for various cofounders did not affect the results. Time since immigration to Israel seemed to modify the relationship, with a stronger association for women who immigrated within 2 years prior to mammography (OR:0.07, 95% CI: 0.03-0.17) as opposed to women with a longer residency stay in Israel (OR:0.23, 95% CI:0.10-0.50). Adjustments of various confounders did not alter these findings. Breast density in Ethiopian immigrants to Israel is significantly lower than that of Israeli-born controls. Our study suggests a positive association between time since immigration and breast density. Future studies are required to define the possible effects of dietary change on mammographic density following immigration. © 2018 Wiley Periodicals, Inc.

  17. Characterization of a mammographic system based on single photon counting pixel arrays coupled to GaAs x-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Amendolia, S. R.; Bisogni, M. G.; Delogu, P.; Fantacci, M. E.; Paternoster, G.; Rosso, V.; Stefanini, A. [Str. Dip. di Matematica e Fisica dell' Universita di Sassari, Via Vienna 2, I-07100, Sassari (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy); Dip. di Fisica ' ' E. Fermi' ' , Universita di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy) and Istituto Nazionale di Fisica Nucleare INFN Sezione di Pisa, Largo B. Pontecorvo 3, I-56127, Pisa (Italy)

    2009-04-15

    The authors report on the imaging capabilities of a mammographic system demonstrator based on GaAs pixel detectors operating in single photon counting (SPC) mode. The system imaging performances have been assessed by means of the transfer functions: The modulation transfer function (MTF), the normalized noise power spectrum, and the detective quantum efficiency (DQE) have been measured following the guidelines of the IEC 62220-1-2 protocol. The transfer function analysis has shown the high spatial resolution capabilities of the GaAs detectors. The MTF calculated at the Nyquist frequency (2.94 cycles/mm) is indeed 60%. The DQE, measured with a standard mammographic beam setup (Mo/Mo, 28 kVp, with 4 mm Al added filter) and calculated at zero frequency, is 46%. Aiming to further improve the system's image quality, the authors investigate the DQE limiting factors and show that they are mainly related to system engineering. For example, the authors show that optimization of the image equalization procedure increases the DQE(0) up to 74%, which is better than the DQE(0) of most clinical mammographic systems. The authors show how the high detection efficiency of GaAs detectors and the noise discrimination associated with the SPC technology allow optimizing the image quality in mammography. In conclusion, the authors propose technological solutions to exploit to the utmost the potentiality of GaAs detectors coupled to SPC electronics.

  18. Karst in the United States: a digital map compilation and database

    Science.gov (United States)

    Weary, David J.; Doctor, Daniel H.

    2014-01-01

    This report describes new digital maps delineating areas of the United States, including Puerto Rico and the U.S. Virgin Islands, having karst or the potential for development of karst and pseudokarst. These maps show areas underlain by soluble rocks and also by volcanic rocks, sedimentary deposits, and permafrost that have potential for karst or pseudokarst development. All 50 States contain rocks with potential for karst development, and about 18 percent of their area is underlain by soluble rocks having karst or the potential for development of karst features. The areas of soluble rocks shown are based primarily on selection from State geologic maps of rock units containing significant amounts of carbonate or evaporite minerals. Areas underlain by soluble rocks are further classified by general climate setting, degree of induration, and degree of exposure. Areas having potential for volcanic pseudokarst are those underlain chiefly by basaltic-flow rocks no older than Miocene in age. Areas with potential for pseudokarst features in sedimentary rocks are in relatively unconsolidated rocks from which pseudokarst features, such as piping caves, have been reported. Areas having potential for development of thermokarst features, mapped exclusively in Alaska, contain permafrost in relatively thick surficial deposits containing ground ice. This report includes a GIS database with links from the map unit polygons to online geologic unit descriptions.

  19. Ambient dose evaluation at mammographic installations through the spectrum of barrier transmitted beams

    International Nuclear Information System (INIS)

    Silva, Marcia C.; Costa, Paulo R.; Herdade, Silvio B.; Furquim, Tania A.C.; Terini, Ricardo A.

    2001-01-01

    National regulations (Ministerial Rule 453, 1998) state that ambient dose equivalent (ADE) must be the operational quantity to verify the conformance with dose constraint levels in area surveys. It's difficulty to evaluate ADE's through conventional radiometric measurements performed in the neighbor areas of examination room because of the low energy levels utilized by mammographic equipment. Therefore, it is necessary to know the radiation spectrum incident in the area. Spectra of X-rays scattered by a breast tissue equivalent phantom have been measured in a controlled area adjacent to a mammography room, using a portable high resolution spectrometer, and taking into account typical workload distributions. The raw spectra was corrected for changes of detector efficiency with photon energy and converted to fluence units (photons/keV.m 2 ). After, air kerma values (in mGy/m As) was calculated for each corrected spectrum. The ADE's (in mSv/year) was obtained by two ways: firstly using the constant conversion factor 1.14 Sv/Gy, adopted by the Ministerial Rule 453 and used in ionization chambers; secondly, through the conversion factor (Sv/Gy) versus energy curve. Results show clearly that the ADE values are overestimated when adopting the usual methodology and that the proposed method furnishes more realistic data for the evaluation of protective shielding. (author)

  20. Development of breast phantom for quality assessment of mammographic images

    International Nuclear Information System (INIS)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata; Universidade Federal de Minas Gerais; Universidad Complutense de Madrid

    2017-01-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  1. Development of breast phantom for quality assessment of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata, E-mail: jenifferarvelos00@gmail.com [Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Biomedica; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Universidad Complutense de Madrid (UCM), Madrid (Spain). Faculdad de Medicina. Departmento de Radiologia

    2017-11-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  2. Should breast MRI be performed with adjustment for the phase in patients’ menstrual cycle? Correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle

    International Nuclear Information System (INIS)

    Uematsu, Takayoshi; Kasami, Masako; Watanabe, Junichiro

    2012-01-01

    Purpose: The purpose of this study was to assess the correlation between mammographic density, age, and background enhancement on breast MRI without adjusting for the phase in patients’ menstrual cycle. Material and methods: The background enhancement of bilateral breast MRI and the breast density of mammography in 146 consecutive women without adjusting for the phase in patients’ menstrual cycle were reviewed. The breast density was classified into four categories according to the American College of Radiology the Breast Imaging Reporting and Data System lexicon. The background enhancement was classified into four categories: minimal, mild, moderate, and marked. The correlations of mammographic breast density as well as age with background enhancement on breast MRI were examined. Results: There was a significant correlation between mammographic breast density and background enhancement (p = 0.011). All nine cases with almost completely fat mammographic breast density showed minimal (78%) or mild (12%) background enhancement on breast MRI. There was a significant inverse correlation between age and background enhancement (p < 0.0001). Younger patients with dense breasts were more likely to demonstrate moderate/marked background enhancement. Conclusion: When no adjusting for the phase in patients’ menstrual cycle, a significant correlation was observed between background enhancement and mammographic density. A significant inverse correlation was also observed between age and background enhancement.

  3. Inter-observer agreement according to three methods of evaluating mammographic density and parenchymal pattern in a case control study

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; von Euler-Chelpin, My Catarina; Nielsen, Mads

    2015-01-01

    , Tabár's PIV and PV and the upper two quartiles (within density range) of PMD. The relative risk of breast cancer was estimated using logistic regression to calculate odds ratios (ORs) adjusted for age, which were compared between the two readers. RESULTS: Substantial inter-observer agreement was seen......, respectively. Inter-reader variability showed different impact on the relative risk of breast cancer estimated by the two readers on a multiple-category scale, however, not on a high/low-risk scale. Tabár's pattern IV demonstrated the highest ORs of all density patterns investigated. CONCLUSIONS: Our study......BACKGROUND: Mammographic breast density and parenchymal patterns are well-established risk factors for breast cancer. We aimed to report inter-observer agreement on three different subjective ways of assessing mammographic density and parenchymal pattern, and secondarily to examine what potential...

  4. Mammographic dose survey in the Czech Republic

    International Nuclear Information System (INIS)

    Novak, Leos; Rada, Jiri

    2006-01-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  5. Mammographic dose survey in the Czech Republic

    Energy Technology Data Exchange (ETDEWEB)

    Novak, Leos [National Radiation Protection Institute, Prague (Czech Republic); Rada, Jiri [National Radiation Protection Institute, Ostrava (Czech Republic)

    2006-07-01

    At present, it is generally accepted that the average dose to the glandular tissue is the most reasonable dose descriptor in mammography with regard to the risk of breast cancer induced by ionizing radiation. It is advantageous to use the quantity mean glandular dose M.G.D. for setting of diagnostic reference levels (D.R.L.) as well, although the quantity is not directly measurable as it is the case of D.R.L. quantities for other imaging modalities. The reason is that a directly measurable quantity suitable for mammography, incident air kerma Ki, depends a lot on a beam quality. The influence of the beam quality (expressed by tube voltage, half value layer and combination of anode/filter material) is already included in calculation of mean glandular dose. To assess a radiation burden of patients due to mammography at a national level a representative dose survey is needed to carry out. Such a study provides statistically significant dose data for setting of the national diagnostic reference levels. National Radiation Protection Institute is performing the study in the Czech Republic since the year 2005.On a basis of presented data, it could be concluded, that the situation in the Czech Republic with respect to patient doses in mammography is encouraging and that the requirements of European Commission are well fulfilled. However, it is obvious, that the obtained results can not be considered as statistically significant at the moment, because the data were not collected from a representative sample of centers, which should observe a distribution of X-ray unit types, type of a mammographic center (screening/non screening ones) and also a locality of a center. The dose survey still continues to cover the whole Czech Republic with the main task to determine new national diagnostic reference levels and to find out optimized standards for carrying out the examinations with respect to patient doses and image quality. (authors)

  6. Decision aids for improved accuracy and standardization of mammographic diagnosis

    International Nuclear Information System (INIS)

    D'Orsi, C.J.; Getty, D.J.; Swets, J.A.; Pickett, R.M.; Seltzer, S.E.; McNeil, B.J.

    1990-01-01

    This paper examines the gains in the accuracy of mammographic diagnosis of breast cancer achievable from a pair of decision aids. Twenty-three potentially relevant perceptual features of mammograms were identified through interviews, psychometric tests, and consensus meetings with mammography specialists. Statistical analyses determined the 12 independent features that were most information diagnostically and assigned a weight to each according to its importance. Two decision aids were developed: a checklist that solicits a scale value from the radiologist for each feature and a computer program that merges those values optimally in an advisory estimate of the probability of malignancy. Six radiologists read a set of 150 cases, first in their usual way and later with the aids

  7. Fibrocystic disease of breast: variable mammographic and sonography appearance

    Energy Technology Data Exchange (ETDEWEB)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye [Chung Ang Gil Hospital, Incheon (Korea, Republic of)

    1993-12-15

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, the echogenicity was variable; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical

  8. Fibrocystic disease of breast: variable mammographic and sonography appearance

    International Nuclear Information System (INIS)

    Han, Heon; Cha, Yoo Mi; Yang, Joo Hyun; Song, Ek Hyun; Hwang, Hee Yong; Chung, Hyo Sun; Park, Sung Hye

    1993-01-01

    Fibrocystic disease of the breast is a frequent cause of abnormal mammogram and ultrasonogram in patients with breast pain. The differentiation of fibrocystic disease form fibroadenoma or carcinoma is often difficult. The present study was performed to evaluate the mammographic and sonographic features of fibrocystic disease of the breast Mammograms and sonogram s of 45 patients with pathologically proven fibrocystic disease of breast were analyzed and correlated retrospectively with the pathologic specimens. Clinically the patients had palpable breast lumps or focal skin thickening. The patients were aged 19 to 64 years(average, 37 years) Histologic examination of 29 patients with abnormal findings in mammograms and/or sonograms revealed stromal fibrosis in 28(97%), cyst formation in 24(83%), epithelial hyperplasia in 29(90%), apocrine metaplasia in 7 (24%), chronic inflammation in 15 (52%), fibroadenomatous change in 2 (7%), large pseudocyst formation in 2 (7%), calcification in 1 (3%), and/or chondroid maseptol in 1 (3%). Of 43 patients with mammograms, 23 showed no detectable lesion, even in retrospect, because of dense mammograms there were well marginated mass in 7, poorly marginated mass in 4, multiple small nodules in 2, mixed density radio opaque mass in 3, radiolucent mass in one, and asymmetrical dense breast in 3. One case had calcification within the mass, and another one had very high density nodules that showed chondroid metaplasia. In 14 patients with sonograms, theechogenicity was variable ; anechoic in 2, hypoechoic in 8, isoechoic in 3, or mixed echoic in one. The shape of the lesion was round in 2, ovoid in 8, tubular in 2, and irregular in 2. The margin was well marginated in 11 and poorly marginated in 3. Fibrocystic breast disease, which is a frequent cause of breast lumps, has variable findings in mammograms and sonograms. Therefore, fibrocystic disease should be included in the differential diagnosis of breast mass when the typical

  9. US and mammographic findings of myofibroblastoma in the female breast: a case report

    International Nuclear Information System (INIS)

    Ko, Seog Wan; Jeon, Soo Bin; Lee, Ji Shin; Kim, Dong Sug

    2005-01-01

    Myofibroblastoma is a rare benign mesenchymal tumor of the breast. It presents as a well circumscribed, solitary nodular mass, and it has been reported to mainly occur in male patients. To our knowledge, few reports have described the radiologic appearance of myofibroblastoma in the female breast and there has been no report from Korea. We describe the mammographic, sonographic and histologic findings of a case of myofibroblastoma that presented as a well defined mass mimicking fibroadenoma in a 44-year-old woman

  10. US and mammographic findings of myofibroblastoma in the female breast: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Seog Wan; Jeon, Soo Bin [Chonbuk University Medical College, Jeonju (Korea, Republic of); Lee, Ji Shin [Chonnam University Medicine College, Gwangju (Korea, Republic of); Kim, Dong Sug [Yeungnam University Medicine College, Daegu (Korea, Republic of)

    2005-07-15

    Myofibroblastoma is a rare benign mesenchymal tumor of the breast. It presents as a well circumscribed, solitary nodular mass, and it has been reported to mainly occur in male patients. To our knowledge, few reports have described the radiologic appearance of myofibroblastoma in the female breast and there has been no report from Korea. We describe the mammographic, sonographic and histologic findings of a case of myofibroblastoma that presented as a well defined mass mimicking fibroadenoma in a 44-year-old woman.

  11. Vacuum-assisted breast biopsy of suspected mammographic breast diagnoses: predictive value of serum proteomic profile

    International Nuclear Information System (INIS)

    Schittulli, F.; Ventrella, V.

    2009-01-01

    The project planned a series of actions oriented to different scientific questions: to complete the prospective collection of serum samples for serum proteomic analysis according to SOPs needed for the Italy-USA program; the identification of different mammographic signs for prediction of histological diagnosis of breast lesions through mammotone; the analysis of relationship between serum proteomic profile and micro histology characteristics of breast lesions

  12. Age as a predictive factor of mammographic breast density in Jamaican women

    International Nuclear Information System (INIS)

    Soares, Deanne; Reid, Marvin; James, Michael

    2002-01-01

    AIM: We sought to determine the relationship between age, and other clinical characteristics such as parity, oestrogen use, dietary factors and menstrual history on breast density in Jamaican women. METHODS AND MATERIALS: A retrospective study was done of 891 patients who attended the breast imaging unit. The clinical characteristics were extracted from the patient records. Mammograms were assessed independently by two radiologists who were blinded to the patient clinical characteristics. Breast densities were assigned using the American College of Radiology (ACR) classification. RESULTS: The concordance between the ACR classification of breast density between the two independent radiologists was 92% with k = 0.76 (SE = 0.02, P -2 vs 26.0 ± 5.2 kg m -2 , P < 0.0001). Mammographic breast density decreased with age. The age adjusted odds ratios (ORs) for predictors significantly related to high breast density were parity, OR = 0.79 (95%CI:0.71, 0.88), weight, OR = 0.92 (95% CI:0.91, 0.95), BMI, OR = 0.83 (95% CI:0.78, 0.89), menopause, OR = 0.51 (95% CI:0.36, 0.74) and a history of previous breast surgery, OR 1.6 (95% CI:1.1, 2.3). CONCLUSION: The rate decline of breast density with age in our population was influenced by parity and body composition. Soares, D. et al. (2002)

  13. Digital radiography

    International Nuclear Information System (INIS)

    Rath, M.; Lissner, J.; Rienmueller, R.; Haendle, J.; Siemens A.G., Erlangen

    1984-01-01

    Using a prototype of an electronic, universal examination unit equipped with a special X-ray TV installation, spotfilm exposures and digital angiographies with high spatial resolution and wide-range contrast could be made in the clinic for the first time. With transvenous contrast medium injection, the clinical results of digital angiography show excellent image quality in the region of the carotids and renal arteries as well as the arteries of the extremities. The electronic series exposures have an image quality almost comparable to the quality obtained with cutfilm changers in conventional angiography. There are certain limitations due to the input field of 25 cm X-ray image intensified used. In respect of the digital angiography imaging technique, the electronic universal unit is fully suitable for clinical application. (orig.) [de

  14. Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Lell, M.; Boehner, C.; Bautz, W.A.; Mertelmeier, T.

    2006-01-01

    Purpose: To compare the sensitivity of conventional two-dimensional (2D) projection imaging with tomosynthesis with respect to the detectability of mammographic phantom lesions. Materials and Methods: Using a breast tomosynthesis prototype based on a commercial FFDM system (Siemens MAMMOMAT Novation DR ), but modified for a wide angle tube motion and equipped with a fast read-out amorphous selenium detector, we acquired standard 2D images and tomosynthesis series of projection views. We used the Wisconsin mammographic random phantom, model RMI 152A. The anode filter combinations Mo/Mo and W/Rh at two different doses were used as typical radiographic techniques. Slice images through the phantom parallel to the detector were reconstructed with a distance of 1 mm employing a filtered back-projection algorithm. The image data sets were read by five radiologists and evaluated with respect to the detectability of the phantom details. Results: For all studied radiographic techniques, the detection rate in the tomosynthesis mode was 100%, i.e. 75 true positive findings out of 75 possible hits. In contrast, the conventional projection mode yielded a detection rate between 80 and 93% (corresponding to 60 and 70 detected details) depending on the dose and X-ray spectrum. Conclusion: Tomosynthesis has the potential to increase the sensitivity of digital mammography. Overlapping structures from out-of-plane tissue can be removed in the tomosynthesis reconstruction process, thereby enhancing the diagnostic accuracy. (orig.)

  15. Impact on breast cancer diagnosis in a multidisciplinary unit after the incorporation of mammography digitalization and computer-aided detection systems.

    Science.gov (United States)

    Romero, Cristina; Varela, Celia; Muñoz, Enriqueta; Almenar, Asunción; Pinto, Jose María; Botella, Miguel

    2011-12-01

    The purpose of this article is to evaluate the impact on the diagnosis of breast cancer of implementing full-field digital mammography (FFDM) in a multidisciplinary breast pathology unit and, 1 year later, the addition of a computer-aided detection (CAD) system. A total of 13,453 mammograms performed between January and July of the years 2004, 2006, and 2007 were retrospectively reviewed using conventional mammography, digital mammography, and digital mammography plus CAD techniques. Mammograms were classified into two subsets: screening and diagnosis. Variables analyzed included cancer detection rate, rate of in situ carcinoma, tumor size at detection, biopsy rate, and positive predictive value of biopsy. FFDM increased the cancer detection rate, albeit not statistically significantly. The detection rate of in situ carcinoma increased significantly using FFDM plus CAD compared with conventional technique (36.8% vs 6.7%; p = 0.05 without Bonferroni statistical correction) for the screening dataset. Relative to conventional mammography, tumor size at detection decreased with digital mammography (T1, 61.5% vs 88%; p = 0.018) and with digital mammography plus CAD (T1, 79.7%; p = 0.03 without Bonferroni statistical correction). Biopsy rates in the general population increased significantly using CAD (10.6/1000 for conventional mammography, 14.7/1000 for digital mammography, and 17.9/1000 for digital mammography plus CAD; p = 0.02). The positive predictive value of biopsy decreased slightly, but not significantly, for both subsets. The incorporation of new techniques has improved the performance of the breast unit by increasing the overall detection rates and earlier detection (smaller tumors), both leading to an increase in interventionism.

  16. Digital management of an electron microscope unit

    International Nuclear Information System (INIS)

    Elea, N.; Dickson, M.; Munroe, P.

    2002-01-01

    Full text: Electron microscope units, especially those such as ours, which operate as a central infrastructural facility are increasingly asked to provide more service, over more instruments with decreasing, or limited, financial resources. We believe that staff time is best used performing electron microscopy, assisting users and maintaining instrumentation rather than in the pursuit of red tape. One solution to this problem has been the creation of a control system which performs all routine acts of data management, such as the archiving and accessing of digital data, providing access to bookings, and most importantly in the era of user pays services, logging time and billing users. The system we have created, developed and expanded allows the users themselves to access our server through any web-browser and make their own bookings or access and manipulate their data. Users themselves must log on to a microscope through swipecard readers before it can be used and log-off after use. Their time is logged precisely and an exquisitely fair user pays systems can be operated by transferring logged usage time to spreadsheets to calculate charges. Furthermore, this system acts as a method of user authentication and can be used to bar incompetent or unauthorised users. The system has recently been upgraded to increase its utility to include sensors that monitor the electron microscope operating environment, such as magnetic field, room temperature, water flow etc, so that if these parameters depart significantly from optimum levels electron microscope unit staff may be alerted. In this presentation the structure of our system will be described and the advantages and disadvantages of such a system will be discussed. Copyright (2002) Australian Society for Electron Microscopy Inc

  17. Mammographic evaluation of suspicious malignant lesions based on ACR(American College of Radiology) breast imaging reporting and data system(BI-RADS)

    International Nuclear Information System (INIS)

    Lee, Jei Hee; Oh, Ki Keun; Chang, So Yong; Kim, Eun Kyung; Kim, Mi Hye

    1999-01-01

    The purpose of this study was to assess the mammographic features and pathologic outcome of category 4 lesions using the Breast Imaging Reporting and Data System(BI-RADS), and to evaluate the significance of final assessment categories. Using BI-RADS, the interpretations of 8,134 mammograms acquired between January 1997 and May 1998 were categorized. From among 161 lesions categorized as '4' ('suspicious abnormality') and pathologically confirmed by surgery or biopsy, we analysed 113, found in 66 patients. The pathologic outcome of these 113 lesions was as follows:infiltrating ductal carcinoma, 17.7%(20/113); DCIS(ductal carcinoma in sitv), 8.0%(9/113); ADH(atypical ductal hyperplasia), 5.3%(6/113); DEH(ductal epithelial hyperplasia), 1.8%(2/113); ductectasia, 0.9%(1/113), FCD(fibrocystic change), 27.4%(31/113); firoadenoma, 7.1%(8/113); stromal fibrosis, 9.7%(11/113); normal parenchyma, 7.1%(8/113); other pathology, 15.0%(17/113). The most frequent mammographic features of BI-RADS category 4 lesions were irregular mass shape(41.2%), spiculated mass margin(52.3%), amorphous calcification(47.3%) and clustered calcification distribution(37.1%). Because category 4 lesions account for about 25.7% of all breast malignancies, mammographic lesions in this category ('suspicious abnormality') should be considered for supplementary study and breast biopsy rather than short-term follow-up. Initial pathologic findings can thus be confirmed

  18. Efficiency of Lu2SiO5:Ce (LSO) powder phosphor as X-ray to light converter under mammographic imaging conditions

    International Nuclear Information System (INIS)

    David, S.; Michail, C.; Valais, I.; Nikolopoulos, D.; Liaparinos, P.; Kalivas, N.; Kalatzis, I.; Toutountzis, A.; Efthimiou, N.; Loudos, G.; Sianoudis, I.; Cavouras, D.; Dimitropoulos, N.; Nomicos, C.D.; Kandarakis, I.; Panayiotakis, G.S.

    2007-01-01

    The aim of the present study was to examine the light emission efficiency of Lu 2 SiO 5 :Ce (LSO) powder scintillator under X-ray mammographic imaging conditions. Powder LSO scintillator has never been used in X-ray imaging. For the purposes of the present study, a 25 mg/cm 2 thick scintillating screen was prepared in our laboratory, by sedimentation of Lu 2 SiO 5 :Ce powder. Absolute luminescence efficiency measurements were performed within the range of X-ray tube voltages (22-49 kVp) used in mammographic applications. Parameters related to X-ray detection, i.e. the energy absorption efficiency (EAE) and the quantum detection efficiency (QDE) were calculated. A theoretical model, describing radiation and light transfer, was employed to fit experimental data and to estimate values of the intrinsic conversion efficiency and the light attenuation coefficients of the screen. The spectral compatibility of the LSO powder scintillator to mammographic X-ray films and to various electronic optical detectors was determined by performing light emission spectrum measurements and by taking into account the spectral sensitivity of the optical detectors. Results in the voltage range used in mammography showed that Lu 2 SiO 5 :Ce powder scintillator has approximately 10% higher values of QDE and 4.5% higher values of EAE than Gd 2 O 2 S:Tb

  19. Reflections on a digital upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Tadjalli, M.

    2013-07-01

    Upon receiving US NRC's approval in 2010, the first RPS/ESPS digital upgrade using TELEPERM® XS technology was successfully installed in Spring of 2011 at the first Unit of a three-unit station, followed by the 2nd Unit installation in spring of 2012. Both Units' systems have been operating flawlessly since installation. After about two years of operation, a reflection on digital upgrades and lessons learned, from a vendor perspective, provides valuable insight for the commercial nuclear power industry.

  20. EnviroAtlas - Percent Land Cover with Potentially Restorable Wetlands on Agricultural Land per 12-Digit HUC - Contiguous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset shows the percent land cover with potentially restorable wetlands on agricultural land for each 12-digit Hydrologic Unit (HUC) watershed in...

  1. [The effect of mammographic screening on tumor size, axillary node status and the degree of histologic anaplasia].

    Science.gov (United States)

    Garami, Zoltán; Benkó, Klára; Kósa, Csaba; Fülöp, Balázs; Lukács, Géza

    2006-10-01

    Breast cancer is the most frequent malignant tumor in women in Hungary. Significant reduction of mortality has been brought about not only by the increasing efficiency of complex therapy but also by regular mammographic screening. Of the histopathological data of 633 patients operated with primary breast tumor at the 1st Surgical Clinic of the Debrecen Medical University between January 1st 2000 and December 31st 2004, the authors analyzed tumor diameter, axillary node status and the degree of histologic anaplasia and compared them with the data of mammographic screening. Of the "screened"patients, 70.7% were diagnosed with T1 size tumors, 28.5% with T2 size, and 0.8% with tumors bigger than that. In the "unscreened" patients, our findings were 44.3%, 45.9% and 9.8% respectively. Within T1 tumors, Tla tumors were found in 11%, TIb in 37.6% and T1c in 51.4% in the "screened" group of patients, while the "unscreened" group's results were 2.3%, 12.6% and 85% respectively. 72.7% of the "screened" patients and 56.2% of the "unscreened" patients were found to be axillary node-negative. A study of the degree of histologic anaplasia showed G-I tumors in 15.6%, G-IIs in 62.1% and G-IIIs in 22.3% of the "screened" patients. The corresponding values for the "unscreened" patients were 6.1%, 53.8% and 40.1%, respectively. The differences were highly significant (p < 0.001) in all the parameters investigated. The authors have found a significant increase in the proportion of node-negative patients and patients with smaller tumors even after the first round of mammographic screening and at less than 50% participation. It is to be hoped that a 20% reduction in mortality can be achieved by further increasing the rate of participation.

  2. Mammographic density and risk of breast cancer by tumor characteristics: a case-control study.

    Science.gov (United States)

    Krishnan, Kavitha; Baglietto, Laura; Stone, Jennifer; McLean, Catriona; Southey, Melissa C; English, Dallas R; Giles, Graham G; Hopper, John L

    2017-12-16

    In a previous paper, we had assumed that the risk of screen-detected breast cancer mostly reflects inherent risk, and the risk of whether a breast cancer is interval versus screen-detected mostly reflects risk of masking. We found that inherent risk was predicted by body mass index (BMI) and dense area (DA) or percent dense area (PDA), but not by non-dense area (NDA). Masking, however, was best predicted by PDA but not BMI. In this study, we aimed to investigate if these associations vary by tumor characteristics and mode of detection. We conducted a case-control study nested within the Melbourne Collaborative Cohort Study of 244 screen-detected cases matched to 700 controls and 148 interval cases matched to 446 controls. DA, NDA and PDA were measured using the Cumulus software. Tumor characteristics included size, grade, lymph node involvement, and ER, PR, and HER2 status. Conditional and unconditional logistic regression were applied as appropriate to estimate the Odds per Adjusted Standard Deviation (OPERA) adjusted for age and BMI, allowing the association with BMI to be a function of age at diagnosis. For screen-detected cancer, both DA and PDA were associated to an increased risk of tumors of large size (OPERA ~ 1.6) and positive lymph node involvement (OPERA ~ 1.8); no association was observed for BMI and NDA. For risk of interval versus screen-detected breast cancer, the association with risk for any of the three mammographic measures did not vary by tumor characteristics; an association was observed for BMI for positive lymph nodes (OPERA ~ 0.6). No associations were observed for tumor grade and ER, PR and HER2 status of tumor. Both DA and PDA were predictors of inherent risk of larger breast tumors and positive nodal status, whereas for each of the three mammographic density measures the association with risk of masking did not vary by tumor characteristics. This might raise the hypothesis that the risk of breast tumours with poorer prognosis

  3. Fibrocystic change in breast; mammographic and ultrasonographic findings in lower risk lesions

    International Nuclear Information System (INIS)

    Kook, Shin Ho; Jung, Kyung Jae; Noh, In Gye

    1996-01-01

    We performed this study to define the characteristic mammographic and ultrasonographic findings in lower risk lesions of fibrocystic change and also tried to evaluate the role of both modalities in planning the treatment of these lesions. We retrospectively reviewed 38 cases of mammography and 46 cases of ultrasonography in biopsy proven 55 cases of fibrocystic change, histologically showing the nonproliferative pattern or proliferative pattern without atypia. We analyzed the mammographic and ultrasonographic findings, final assessments, and compared the effectiveness of each modality. On mammography, there were no abnormatlities in 20 cases(53%), nodules or masses in 9 cases(24%), microcalcifications in 6 cases(16%) and asymmetric density in 5 cases(14%). On ultrasonography, there were 40 cases(87%) of focal sonographic abnormality and no abnormality in 6 cases(13%). Most focal sonographic abnormalities were smooth(40 cases, 93%), well-defined(21 cases, 49%) or ill-defined(22 cases, 51%) round or oval(36 cases, 84%) shaped, homogeneous(31 cases, 67%), hypoechoic(30 cases, 65%) lesions. Final assessment revealed that only 7 cases(18%) of mammography and 8 cases(18%) of ultrasound examinations were included into the category of indeterminate and malignancy groups which were recommended biopsy. Mammography was excellent to demonstrate the microcalcifications and ultrasonography was effective in depiction of the focal lesions. The mammography and ultrasonography findings were not specific in diagnosing lower risk group of fibrocystic change. But complementary study of both modalities in conjunction with clinical findings will be helpful in making decision among biopsy, fine needle aspiration, and simple close follow up of the lesions

  4. Fibrocystic change in breast; mammographic and ultrasonographic findings in lower risk lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kook, Shin Ho; Jung, Kyung Jae; Noh, In Gye [Kangbuk Samsung Hospital, Seoul (Korea, Republic of)

    1996-01-01

    We performed this study to define the characteristic mammographic and ultrasonographic findings in lower risk lesions of fibrocystic change and also tried to evaluate the role of both modalities in planning the treatment of these lesions. We retrospectively reviewed 38 cases of mammography and 46 cases of ultrasonography in biopsy proven 55 cases of fibrocystic change, histologically showing the nonproliferative pattern or proliferative pattern without atypia. We analyzed the mammographic and ultrasonographic findings, final assessments, and compared the effectiveness of each modality. On mammography, there were no abnormatlities in 20 cases(53%), nodules or masses in 9 cases(24%), microcalcifications in 6 cases(16%) and asymmetric density in 5 cases(14%). On ultrasonography, there were 40 cases(87%) of focal sonographic abnormality and no abnormality in 6 cases(13%). Most focal sonographic abnormalities were smooth(40 cases, 93%), well-defined(21 cases, 49%) or ill-defined(22 cases, 51%) round or oval(36 cases, 84%) shaped, homogeneous(31 cases, 67%), hypoechoic(30 cases, 65%) lesions. Final assessment revealed that only 7 cases(18%) of mammography and 8 cases(18%) of ultrasound examinations were included into the category of indeterminate and malignancy groups which were recommended biopsy. Mammography was excellent to demonstrate the microcalcifications and ultrasonography was effective in depiction of the focal lesions. The mammography and ultrasonography findings were not specific in diagnosing lower risk group of fibrocystic change. But complementary study of both modalities in conjunction with clinical findings will be helpful in making decision among biopsy, fine needle aspiration, and simple close follow up of the lesions.

  5. Occult inflammatory breast cancer: review of clinical, mammographic, US and pathologic signs

    International Nuclear Information System (INIS)

    Cumo, Francesca; Gaioni, Maria Berenice; Bonetti, Franco; Manfrin, Erminia; Remo, Andrea; Pattaro, Christian; Policlinico G.B. Rossi, Verona

    2005-01-01

    Purpose: To examine the clinical, radiologic and pathologic findings of occult inflammatory breast cancer (OIBC) in order to identify features useful for diagnosis. Materials and methods: We retrospectively reviewed the records of 19 women with OIBC observed at our Department between 1992 and 2001. We analysed the clinical history, mammographic, ultrasonographic, and pathologic findings and investigated overall survival (OS), prognostic variables and radio-pathologic correlations. Results: The most common mammographic findings were: diffusely density (52.63%), trabecular thickening (42.1%), mass (36.84%). The most common US findings were axillary lymphadenopathy (68,75%), skin thickening (43.75%) and mass (56.25%). At least one inflammatory sign was found in 14 women (74%) at mammography (subcutaneous thickening, trabecular thickening, diffuse increase of density) or at US (subcutaneous thickening, diffuse increase in echogenicity due to oedema, lymph vessel dilatation). Estrogen receptors (ER) were present in 63.2% and Progesterone receptors (PgR) in 36.8%. Significant prognostic variables were ER and Ki 67. Conclusions: The typical radiological pattern of clinical inflammatory breast carcinoma is less frequently present in OIBC; nevertheless the radiologist must pay attention because frequently OIBC presents just one radiological sign and this should be enough for a diagnostic suspicion. Moreover, the absence of clinical and radiological inflammatory signs does not exclude inflammatory breasts cancer because OIBC can manifest at imaging as a mass or isolated calcification. ER and PgR are positive in a high percentage of patients and confirm that OIBC has a better prognosis that clinical inflammatory breast cancer [it

  6. Computerized classification of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Giger, M.L.; Doi, K.; Yin, F.F.; Schmidt, R.A.; Vyborny, C.J.

    1989-01-01

    Subjective classification of masses on mammograms is a difficult task. On average, about 25% of masses referred for surgical biopsy are actually malignant. The authors are developing, as an aid to radiologists, a computerized scheme for the classification of lesions in mammograms to reduce the false-negative and false-positive diagnoses of malignancies. The classification scheme involves the extraction of border information from the mammographic lesion in order to quantify the degree of spiculation, which is related to the possibility of malignancy. Clinical film mammograms are digitized with an optical drum scanner (0.1-mm pixel size) for analysis on a Micro VAX 3500 computer. Border information (fluctuations) is obtained from the difference between the lesion border and its smoothed border. Using the rms variation of the frequency content of these fluctuations, approximately 85% of the cancerous lesions were correctly classified as malignant, while 15% of benign lesions were misclassified, in a preliminary study

  7. Morphological topology generation of a digital fluid power displacement unit using Chebychev-Grübler-Kutzbach constraint

    DEFF Research Database (Denmark)

    Johansen, Per; Roemer, Daniel Beck; Andersen, Torben O.

    2015-01-01

    The task of designing a digital fluid power displacement unit entails a choice of topology. Consequently, this choice entails a need for knowledge of the various applicable topologies to choose from. In this paper a morphological topology generation approach is used to derive a series of radial...

  8. Controlled single-blind clinical evaluation of low-dose mammographic screen: film systems

    International Nuclear Information System (INIS)

    Sickles, E.A.; Genant, H.K.

    1979-01-01

    The ability of five low-dose mammographic screen-film systems to portray normal and abnormal breast structures was evaluated in parallel with a study of physical image properties. Single-blind evaluations of the visibility of normal breast architecture, mass lesions, and calcifications were made on the mammograms of 100 patients radiographed with each of the systems. There was increased noise and slightly poorer resolution of the faster recording systems, but there was no difference in final diagnostic impressions among the five systems. These results suggest that the faster systems will result in substantial dose reduction without sacrificing diagnostic accuracy

  9. Teleradiology in a neonatal intensive care unit: Comparison between the interpretation of transmitted digital images and film radiographs

    International Nuclear Information System (INIS)

    McFee, W.H.; Bramson, R.T.; Cates, J.D.; Curran, J.S.

    1987-01-01

    Using a Raytel teleradiology system, a prospective comparison was made between the interpretations of 700 transmitted digital images and the film radiographs from which these digital images were made. The original films consisted of all of the radiographs obtained from the infants in a 40-bed level III neonatal intensive care unit over a 6-week period. Interpretations were done by two radiologists, initially from transmitted images and subsequently from the original films. Comparison of the interpretations demonstrates a remarkably high degree of correlation, with less than 0.5% clinically significant discrepancies reported

  10. Affinity proteomic profiling of plasma for proteins associated to area-based mammographic breast density.

    Science.gov (United States)

    Byström, Sanna; Eklund, Martin; Hong, Mun-Gwan; Fredolini, Claudia; Eriksson, Mikael; Czene, Kamila; Hall, Per; Schwenk, Jochen M; Gabrielson, Marike

    2018-02-14

    Mammographic breast density is one of the strongest risk factors for breast cancer, but molecular understanding of how breast density relates to cancer risk is less complete. Studies of proteins in blood plasma, possibly associated with mammographic density, are well-suited as these allow large-scale analyses and might shed light on the association between breast cancer and breast density. Plasma samples from 1329 women in the Swedish KARMA project, without prior history of breast cancer, were profiled with antibody suspension bead array (SBA) assays. Two sample sets comprising 729 and 600 women were screened by two different SBAs targeting a total number of 357 proteins. Protein targets were selected through searching the literature, for either being related to breast cancer or for being linked to the extracellular matrix. Association between proteins and absolute area-based breast density (AD) was assessed by quantile regression, adjusting for age and body mass index (BMI). Plasma profiling revealed linear association between 20 proteins and AD, concordant in the two sets of samples (p density and processes of tissue homeostasis, DNA repair, cancer development and/or progression in breast cancer. Further validation and follow-up studies of the shortlisted protein candidates in independent cohorts will be needed to infer their role in breast density and its progression in premenopausal and postmenopausal women.

  11. Impact of Breast Reader Assessment Strategy on mammographic radiologists' test reading performance.

    Science.gov (United States)

    Suleiman, Wasfi I; Rawashdeh, Mohammad A; Lewis, Sarah J; McEntee, Mark F; Lee, Warwick; Tapia, Kriscia; Brennan, Patrick C

    2016-06-01

    The detection of breast cancer is somewhat limited by human factors, and thus there is a need to improve reader performance. This study assesses whether radiologists who regularly undertake the education in the form of the Breast Reader Assessment Strategy (BREAST) demonstrate any changes in mammography interpretation performance over time. In 2011, 2012 and 2013, 14 radiologists independently assessed a year-specific BREAST mammographic test-set. Radiologists read a different single test-set once each year, with each comprising 60 digital mammogram cases. Radiologists marked the location of suspected lesions without computer-aided diagnosis (CAD) and assigned a confidence rating of 2 for benign and 3-5 for malignant lesions. The mean sensitivity, specificity, location sensitivity, JAFROC FOM and ROC AUC were calculated. A Kruskal-Wallis test was used to compare the readings for the 14 radiologists across the 3 years. Wilcoxon signed rank test was used to assess comparison between pairs of years. Relationships between changes in performance and radiologist characteristics were examined using a Spearman's test. Significant increases were noted in mean sensitivity (P = 0.01), specificity (P = 0.01), location sensitivity (P = 0.001) and JAFROC FOM (P = 0.001) between 2011 and 2012. Between 2012 and 2013, significant improvements were noted in mean sensitivity (P = 0.003), specificity (P = 0.002), location sensitivity (P = 0.02), JAFROC FOM (P = 0.005) and ROC AUC (P = 0.008). No statistically significant correlations were shown between the levels of improvement and radiologists' characteristics. Radiologists' who undertake the BREAST programme demonstrate significant improvements in test-set performance during a 3-year period, highlighting the value of ongoing education through the use of test-set. © 2016 The Royal Australian and New Zealand College of Radiologists.

  12. A Survey On Mean Glandular Dose From Full-Field Digital Mammography Systems, Operate Using Mo/ Mo And W/Rh Target/ Filter Combinations

    International Nuclear Information System (INIS)

    Noriah Jamal; Siti Selina Abdul Hamid; Humairah Samad Cheung; Siti Kamariah Che Mohamed; Ellyda Muhammed Nordin; Radhiana Hassan; Rehir Dahalan

    2013-01-01

    We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems (FFDM) operate using Molybdenum/ Molybdenum (Mo/ Mo) and Tungsten/ Rhodium (W/ Rh) target/ filter combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely National Cancer Society and International Islamic University of Malaysia. The first centre operates using a W/ Rh, while the second centre operates using an Mo/ Mo target/ filter combinations. On the basis of recorded information, data on mammographic views, MGD, age and Compressed Breast Thickness (CBT) were recorded for 100 patients, for each mammographic centre respectively. The MGD data were analyzed for variation with age group, with 5 years increment. The MGD data were also analyzed for variation with CBT, with 5 mm increment. We found that for both CC and MLO views, FFDM systems operated using Mo/ Mo and W/ Rh target/ filter combinations present the same trend on MGD. The average MGD decreases as age increases. While average MGD increases with the increasing of CBT. However, FFDM system operates using Mo/ Mo gives higher MGD as compared with FFDM system operates using W/ Rh. (author)

  13. In the digital era, architectural distortion remains a challenging radiological task

    International Nuclear Information System (INIS)

    Suleiman, W.I.; McEntee, M.F.; Lewis, S.J.; Rawashdeh, M.A.; Georgian-Smith, D.; Heard, R.; Tapia, K.; Brennan, P.C.

    2016-01-01

    Aim: To compare readers' performance in detecting architectural distortion (AD) compared with other breast cancer types using digital mammography. Materials and methods: Forty-one experienced breast screen readers (20 US and 21 Australian) were asked to read a single test set of 30 digitally acquired mammographic cases. Twenty cases had abnormal findings (10 with AD, 10 non-AD) and 10 cases were normal. Each reader was asked to locate and rate any abnormalities. Lesion and case-based performance was assessed. For each collection of readers (US; Australian; combined), jackknife free-response receiver operating characteristic (JAFROC), figure of merit (FOM), and inferred receiver operating characteristic (ROC), area under curve (Az) were calculated using JAFROC v.4.1 software. Readers' sensitivity, location sensitivity, JAFROC, FOM, ROC, Az scores were compared between cases groups using Wilcoxon's signed ranked test statistics. Results: For lesion-based analysis, significantly lower location sensitivity (p=0.001) was shown on AD cases compared with non-AD cases for all reader collections. The case-based analysis demonstrated significantly lower ROC Az values (p=0.02) for the first collection of readers, and lower sensitivity for the second collection of readers (p=0.04) and all-readers collection (p=0.008), for AD compared with non-AD cases. Conclusions: The current work demonstrates that AD remains a challenging task for readers, even in the digital era. - Highlights: • Architectural Distortion interpretation remains challenging for readers even with digital acquisition. • Significantly lower location sensitivity and sensitivity values for the AD were shown.

  14. Combining different views of mammographic texture resemblance (MTR) marker of breast cancer risk

    DEFF Research Database (Denmark)

    Sun, S.; Karemore, Gopal; Chernoff, Konstantin

    the subsequent 4 years whereas 245 cases had a diagnosis 2-4 years post mammography. We employed the MTR supervised texture learning framework to perform risk evaluation from a single mammography view. In the framework 20,000 pixels were sampled and classified by a kNN pixel classifier. A feature selection step......PURPOSE Mammographic density is a well established breast cancer risk factor. Texture analysis in terms of the Mammographoc Texture Resemblance (MTR) marker has recently shown to add to risk segregation. Hitherto only single view MTR analysis has been performed. Standard mammography examinations...

  15. Using Five Machine Learning for Breast Cancer Biopsy Predictions Based on Mammographic Diagnosis

    OpenAIRE

    Oyewola, David; Hakimi, Danladi; Adeboye, Kayode; Shehu, Musa Danjuma

    2017-01-01

    Breast cancer is one of thecauses of female death in the world. Mammography  is commonly  used for  distinguishing  malignant tumors  from benign  ones. In this research,  a mammographic  diagnostic method  is  presented for breast  cancer  biopsy outcome  predictions  using  fivemachine learning which includes: Logistic Regression(LR), Linear DiscriminantAnalysis(LDA), Quadratic Discriminant Analysis(QDA), Random Forest(RF) andSupport  Vector Machine(SVM)  classification.  The testing result...

  16. Fertility drug use and mammographic breast density in a mammography screening cohort of premenopausal women

    OpenAIRE

    Sprague, Brian L.; Trentham-Dietz, Amy; Terry, Mary Beth; Nichols, Hazel B.; Bersch, Andy J.; Buist, Diana S. M.

    2008-01-01

    The widespread use of ovulation-inducing drugs to enhance fertility has raised concerns regarding potential effects on breast cancer risk, as ovarian stimulation is associated with increases in estrogen and progesterone levels. We investigated the short-term relation between fertility drug use and mammographic breast density, a strong marker of breast cancer risk, among participants in the Group Health Breast Cancer Screening Program. Data linkage with Group Health’s automated pharmacy record...

  17. Variability of breast density assessment in short-term reimaging with digital mammography

    International Nuclear Information System (INIS)

    Kim, Won Hwa; Moon, Woo Kyung; Kim, Sun Mi; Yi, Ann; Chang, Jung Min; Koo, Hye Ryoung; Lee, Su Hyun; Cho, Nariya

    2013-01-01

    Objective: To evaluate the variability of breast density assessments in short-term reimaging with digital mammography. Materials and methods: In 186 women, short term (mean interval, 27.6 days) serial digital mammograms including CC and MLO views were obtained without any treatment. Mammographic density assessments were performed by three blinded radiologists for Breast Imaging Report and Data System (BI-RADS, grades 1–4) and visual percentage density (PD) estimation, and by one radiologist for computer-aided PD estimation. The variability of assessments was analyzed according to the age, breast density, and mammography types by multivariate logistic regression. Results: In BI-RADS assessments, 29% (161 of 558) of breast density categories were assessed differently after short-term reimaging and the mean absolute difference in PD for CC and MLO view was 7.6% and 8.1% for visual assessments, and 7.4% and 6.4% for computer-aided assessments, respectively. Among all computer-aided assessments, 29% (54 of 186) of CC view and 22% (41 of 186) of MLO view assessments had discrepancy over 10% in PD. Younger age (<50), greater breast density (grades 3 and 4), and different mammography types were significantly associated with the variability. Conclusion: Considerable variability in breast density assessments occurred in short-term reimaging with digital mammography, particularly in women with younger age and greater breast density and when examined using different types of mammography

  18. Variability of breast density assessment in short-term reimaging with digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Hwa [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Moon, Woo Kyung, E-mail: moonwk@snu.ac.kr [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Sun Mi [Department of Radiology, Seoul National University Bundang Hospital, Gyeonggi-do (Korea, Republic of); Yi, Ann [Department of Radiology, Seoul Metropolitan Government Seoul National University, Boramae Medical Center, Seoul (Korea, Republic of); Chang, Jung Min; Koo, Hye Ryoung; Lee, Su Hyun; Cho, Nariya [Department of Radiology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2013-10-01

    Objective: To evaluate the variability of breast density assessments in short-term reimaging with digital mammography. Materials and methods: In 186 women, short term (mean interval, 27.6 days) serial digital mammograms including CC and MLO views were obtained without any treatment. Mammographic density assessments were performed by three blinded radiologists for Breast Imaging Report and Data System (BI-RADS, grades 1–4) and visual percentage density (PD) estimation, and by one radiologist for computer-aided PD estimation. The variability of assessments was analyzed according to the age, breast density, and mammography types by multivariate logistic regression. Results: In BI-RADS assessments, 29% (161 of 558) of breast density categories were assessed differently after short-term reimaging and the mean absolute difference in PD for CC and MLO view was 7.6% and 8.1% for visual assessments, and 7.4% and 6.4% for computer-aided assessments, respectively. Among all computer-aided assessments, 29% (54 of 186) of CC view and 22% (41 of 186) of MLO view assessments had discrepancy over 10% in PD. Younger age (<50), greater breast density (grades 3 and 4), and different mammography types were significantly associated with the variability. Conclusion: Considerable variability in breast density assessments occurred in short-term reimaging with digital mammography, particularly in women with younger age and greater breast density and when examined using different types of mammography.

  19. Insulin-like growth factor-I (IGF-1), IGF-binding protein-3 (IGFBP-3) and mammographic features.

    Science.gov (United States)

    Izzo, L; Meggiorini, M L; Nofroni, I; Pala, A; De Felice, C; Meloni, P; Simari, T; Izzo, S; Pugliese, F; Impara, L; Merlini, G; Di Cello, P; Cipolla, V; Forcione, A R; Paliotta, A; Domenici, L; Bolognese, A

    2012-05-01

    The IGF system has recently been shown to play an important role in the regulation of breast tumor cell proliferation. However, also breast density is currently considered as the strongest breast cancer risk factor. It is not yet clear whether these factors are interrelated and if and how they are influenced by menopausal status. The purpose of this study was to examine the possible effects of IGF-1 and IGFBP-3 and IGF-1/IGFBP-3 molar ratio on mammographic density stratified by menopausal status. A group of 341 Italian women were interviewed to collect the following data: family history of breast cancer, reproductive and menstrual factors, breast biopsies, previous administration of hormonal contraceptive therapy, hormone replacement therapy (HRT) in menopause and lifestyle information. A blood sample was drawn for determination of IGF-1, IGFBP-3 levels. IGF-1/ IGFBP-3 molar ratio was then calculated. On the basis of recent mammograms the women were divided into two groups: dense breast (DB) and non-dense breast (NDB). Student's t-test was employed to assess the association between breast density and plasma level of IGF-1, IGFBP-3 and molar ratio. To assess if this relationship was similar in subgroups of pre- and postmenopausal women, the study population was stratified by menopausal status and Student's t-test was performed. Finally, multivariate analysis was employed to evaluate if there were confounding factors that might influence the relationship between growth factors and breast density. The analysis of the relationship between mammographic density and plasma level of IGF-1, IGFBP-3 and IGF-1/ IGFBP-3 molar ratio showed that IGF-1 levels and molar ratio varied in the two groups resulting in higher mean values in the DB group (IGF-1: 109.6 versus 96.6 ng/ml; p= 0.001 and molar ratio 29.4 versus 25.5 ng/ml; p= 0.001) whereas IGFBP-3 showed similar values in both groups (DB and NDB). Analysis of plasma level of IGF-1, IGFBP-3 and IGF-1/IGFBP-3 molar ratio

  20. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. Mammographic evaluation of suspicious malignant lesions based on ACR(American College of Radiology) breast imaging reporting and data system(BI-RADS)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jei Hee; Oh, Ki Keun; Chang, So Yong; Kim, Eun Kyung; Kim, Mi Hye [Yonsei Univ. College of Medicine, Research Institute of Radiological Science, Yonsei Univ., Seoul (Korea, Republic of)

    1999-12-01

    The purpose of this study was to assess the mammographic features and pathologic outcome of category 4 lesions using the Breast Imaging Reporting and Data System(BI-RADS), and to evaluate the significance of final assessment categories. Using BI-RADS, the interpretations of 8,134 mammograms acquired between January 1997 and May 1998 were categorized. From among 161 lesions categorized as '4' ('suspicious abnormality') and pathologically confirmed by surgery or biopsy, we analysed 113, found in 66 patients. The pathologic outcome of these 113 lesions was as follows:infiltrating ductal carcinoma, 17.7%(20/113); DCIS(ductal carcinoma in sitv), 8.0%(9/113); ADH(atypical ductal hyperplasia), 5.3%(6/113); DEH(ductal epithelial hyperplasia), 1.8%(2/113); ductectasia, 0.9%(1/113), FCD(fibrocystic change), 27.4%(31/113); firoadenoma, 7.1%(8/113); stromal fibrosis, 9.7%(11/113); normal parenchyma, 7.1%(8/113); other pathology, 15.0%(17/113). The most frequent mammographic features of BI-RADS category 4 lesions were irregular mass shape(41.2%), spiculated mass margin(52.3%), amorphous calcification(47.3%) and clustered calcification distribution(37.1%). Because category 4 lesions account for about 25.7% of all breast malignancies, mammographic lesions in this category ('suspicious abnormality') should be considered for supplementary study and breast biopsy rather than short-term follow-up. Initial pathologic findings can thus be confirmed.

  2. EnviroAtlas - Biological nitrogen fixation in natural/semi-natural ecosystems by 12-digit HUC for the Conterminous United States, 2006

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset contains data on the mean biological nitrogen fixation in natural/semi-natural ecosystems per 12-digit Hydrologic Unit (HUC) in 2006....

  3. A Medipix2-based imaging system for digital mammography with silicon pixel detectors

    CERN Document Server

    Bisogni, M G; Fantacci, M E; Mettivier, G; Montesi, M C; Novelli, M; Quattrocchi, M; Rosso, V; Russo, P; Stefanini, A

    2004-01-01

    In this paper we present the first tests of a digital imaging system based on a silicon pixel detector bump-bonded to an integrated circuit operating in single photon counting mode. The X-rays sensor is a 300 mu m thick silicon, 14 by 14 mm/sup 2/, upon which a matrix of 256 * 256 pixels has been built. The read-out chip, named MEDIPIX2, has been developed at CERN within the MEDIPIX2 Collaboration and it is composed by a matrix of 256 * 256 cells, 55 * 55 mu m/sup 2/. The spatial resolution properties of the system have been assessed by measuring the square wave resolution function (SWRF) and first images of a standard mammographic phantom were acquired using a radiographic tube in the clinical irradiation condition. (5 refs).

  4. Case base classification on digital mammograms: improving the performance of case base classifier

    Science.gov (United States)

    Raman, Valliappan; Then, H. H.; Sumari, Putra; Venkatesa Mohan, N.

    2011-10-01

    Breast cancer continues to be a significant public health problem in the world. Early detection is the key for improving breast cancer prognosis. The aim of the research presented here is in twofold. First stage of research involves machine learning techniques, which segments and extracts features from the mass of digital mammograms. Second level is on problem solving approach which includes classification of mass by performance based case base classifier. In this paper we build a case-based Classifier in order to diagnose mammographic images. We explain different methods and behaviors that have been added to the classifier to improve the performance of the classifier. Currently the initial Performance base Classifier with Bagging is proposed in the paper and it's been implemented and it shows an improvement in specificity and sensitivity.

  5. Comparison of subjective and fully automated methods for measuring mammographic density.

    Science.gov (United States)

    Moshina, Nataliia; Roman, Marta; Sebuødegård, Sofie; Waade, Gunvor G; Ursin, Giske; Hofvind, Solveig

    2018-02-01

    Background Breast radiologists of the Norwegian Breast Cancer Screening Program subjectively classified mammographic density using a three-point scale between 1996 and 2012 and changed into the fourth edition of the BI-RADS classification since 2013. In 2015, an automated volumetric breast density assessment software was installed at two screening units. Purpose To compare volumetric breast density measurements from the automated method with two subjective methods: the three-point scale and the BI-RADS density classification. Material and Methods Information on subjective and automated density assessment was obtained from screening examinations of 3635 women recalled for further assessment due to positive screening mammography between 2007 and 2015. The score of the three-point scale (I = fatty; II = medium dense; III = dense) was available for 2310 women. The BI-RADS density score was provided for 1325 women. Mean volumetric breast density was estimated for each category of the subjective classifications. The automated software assigned volumetric breast density to four categories. The agreement between BI-RADS and volumetric breast density categories was assessed using weighted kappa (k w ). Results Mean volumetric breast density was 4.5%, 7.5%, and 13.4% for categories I, II, and III of the three-point scale, respectively, and 4.4%, 7.5%, 9.9%, and 13.9% for the BI-RADS density categories, respectively ( P for trend density categories was k w  = 0.5 (95% CI = 0.47-0.53; P density increased with increasing density category of the subjective classifications. The agreement between BI-RADS and volumetric breast density categories was moderate.

  6. Easy digital engineering

    International Nuclear Information System (INIS)

    Jin, Dal Bok

    2002-02-01

    This book lists basic of digital engineering, number system and digital code, Boolean algebra and basic logic circuit, simplify of logical expression, combinational circuit, arithmetic circuit, multivibrator circuit, sequential circuit, memory unit of semiconductor and logical element for program, D/A converter and A/D converter, logic element and integrated circuit and logic circuit and micro controller. It has exercises and answers about digital engineering and summary in the end of each chapter.

  7. Construction of mammographic examination process ontology using bottom-up hierarchical task analysis.

    Science.gov (United States)

    Yagahara, Ayako; Yokooka, Yuki; Jiang, Guoqian; Tsuji, Shintarou; Fukuda, Akihisa; Nishimoto, Naoki; Kurowarabi, Kunio; Ogasawara, Katsuhiko

    2018-03-01

    Describing complex mammography examination processes is important for improving the quality of mammograms. It is often difficult for experienced radiologic technologists to explain the process because their techniques depend on their experience and intuition. In our previous study, we analyzed the process using a new bottom-up hierarchical task analysis and identified key components of the process. Leveraging the results of the previous study, the purpose of this study was to construct a mammographic examination process ontology to formally describe the relationships between the process and image evaluation criteria to improve the quality of mammograms. First, we identified and created root classes: task, plan, and clinical image evaluation (CIE). Second, we described an "is-a" relation referring to the result of the previous study and the structure of the CIE. Third, the procedural steps in the ontology were described using the new properties: "isPerformedBefore," "isPerformedAfter," and "isPerformedAfterIfNecessary." Finally, the relationships between tasks and CIEs were described using the "isAffectedBy" property to represent the influence of the process on image quality. In total, there were 219 classes in the ontology. By introducing new properties related to the process flow, a sophisticated mammography examination process could be visualized. In relationships between tasks and CIEs, it became clear that the tasks affecting the evaluation criteria related to positioning were greater in number than those for image quality. We developed a mammographic examination process ontology that makes knowledge explicit for a comprehensive mammography process. Our research will support education and help promote knowledge sharing about mammography examination expertise.

  8. Investigation on location-dependent detectability of a small mass for digital breast tomosynthesis evaluation

    Science.gov (United States)

    Lee, Changwoo; Baek, Jongduk; Park, Subok

    2016-03-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality for improved breast cancer detection and diagnosis [1-5]. Numerous efforts have been made to find quantitative metrics associated with mammographic image quality assessment, such as the exponent β of anatomical noise power spectrum, glandularity, contrast noise ratio, etc. [6-8]. In addition, with the use of Fourier-domain detectability for a task-based assessment of DBT, a stationarity assumption on reconstructed image statistics was often made [9-11], resulting in the use of multiple regions-of-interest (ROIs) from different locations in order to increase sample size. While all these metrics provide some information on mammographic image characteristics and signal detection, the relationship between these metrics and detectability in DBT evaluation has not been fully understood. In this work, we investigated spatial-domain detectability trends and levels as a function of the number of slices Ns at three different ROI locations on the same image slice, where background statistics differ in terms of the aforementioned metrics. Detectabilities for the three ROI locations were calculated using multi-slice channelized Hotelling observers with 2D/3D Laguerre-Gauss channels. Our simulation results show that detectability levels and trends as a function of Ns vary across these three ROI locations. They also show that the exponent β, mean glandularity, and mean attenuation coefficient vary across the three ROI locations but they do not necessarily predict the ranking of detectability levels and trends across these ROI locations.

  9. Functional integration of digital radiologic equipment

    International Nuclear Information System (INIS)

    Agnifili, A.; DiStefano, G.; Salcito, G.; Passariello, R.

    1989-01-01

    This paper reports on a pilot project for the functional integration of digital radiologic equipment. Four different systems (a digital subtraction angiography unit, a DF unit, a computer radiography prototype, and a film digitizer) were connected with a link in an Ethernet LAN.ACR-NEMA standards were used to process the images of the different units in the same way. The central computer manages the long-term optical archive and the film laser printer. Some graphic workstations are connected to the picture archiving and communications system, which allows fast retrieval and processing of the images. Patients; data are acquired through the RIS and stored together with the images

  10. Technique for evaluation of spatial resolution and microcalcifications in digital and scanned images of a standard breast phantom

    International Nuclear Information System (INIS)

    Santana, Priscila do C.; Gomes, Danielle S.; Oliveira, Marcio A.; Oliveira, Paulo Marcio C. de; Meira-Belo, Luiz C.; Nogueira-Tavares, Maria S.

    2011-01-01

    In this work, an automated methodology to evaluate digital and scanned images of a standard phantom (Phantom Mama) was studied. The Phantom Mama was used as an important tool to check the quality of mammographs. The scanned images were digitized using a ScanMaker 9800XL, with resolution of 900 dpi. The aim of this work is to test an automatic methodology for evaluation of spatial resolution and microcalcifications group of phantom mama images acquired with the same parameters in the same equipment. In order to analyze the images we have used the ImageJ software (in Java) which is public domain. We have used the Fast Fourier transform technique to evaluate the spatial resolution and used the ImageJ function Subtract Background and the Light Background plus Sliding Paraboloid on the evaluation of the five groups of microcalcifications on the breast phantom to assess the viability of using automated methods for both types of images. The methodology was adequate for evaluated the microcalcifications group and the spatial resolution in scanned and digital images, but the Phantom Mama doesn't provide sufficient parameters to evaluate the spatial resolution in this images. (author)

  11. The power and the pain: Mammographic compression research from the service-users' perspective

    International Nuclear Information System (INIS)

    Robinson, Leslie; Hogg, Peter; Newton-Hughes, Ann

    2013-01-01

    Purpose: to explore the value service-users can add to our understanding of inter-practitioner compression variability in mammography. Imaging of the breast for the screening and detection of breast carcinoma is generally carried out by mammographic examination the technique for which includes compression of the breast. Evolving research calls into question compression practice in terms of practitioner consistency thus raising the possibility that strong compression may not be required. We were interested to know whether this was important to service-users and if such knowledge might influence their behaviour. Methods: and sample: A qualitative study involving 3 focus groups interviews (n = 4, 6 and 5). Participants were first asked to reflect on their own experiences of breast compression within the context of a breast screening examination, then interpret the results of the evolving research detailed above. We then explored whether these participants might behave differently during future mammography in light being appraised of these research findings. Results: A grounded approach was used to analyse the data into themes. The two overarching themes were i) Service-User Empowerment, which illustrates the difficulties participants believe women would encounter in exercising power in the breast screening mammographic examination; and ii) Service User Experience of Mammography, which unearthed unanticipated aspects of the examination, other than compression, that contribute to pain and discomfort and which therefore need investigation. Conclusion: Involving service-users more collaboratively in research can help investigators understand the impact of their work and highlight patient-relevant areas for further investigation

  12. Design and implementation of interface units for high speed fiber optics local area networks and broadband integrated services digital networks

    Science.gov (United States)

    Tobagi, Fouad A.; Dalgic, Ismail; Pang, Joseph

    1990-01-01

    The design and implementation of interface units for high speed Fiber Optic Local Area Networks and Broadband Integrated Services Digital Networks are discussed. During the last years, a number of network adapters that are designed to support high speed communications have emerged. This approach to the design of a high speed network interface unit was to implement package processing functions in hardware, using VLSI technology. The VLSI hardware implementation of a buffer management unit, which is required in such architectures, is described.

  13. Development of prototype digital LLRF system at RRCAT

    International Nuclear Information System (INIS)

    Tiwari, Nitesh; Bagduwal, Pritam S.; Sharma, Dheeraj; Chakraborty, Shoubhik; Lad, Mahendra; Hannurkar, P.R.

    2013-01-01

    RF field is used in accelerator to accelerate the charge particles. The beam parameters depend highly on the stability of the RF field. Due to dynamic beam loading conditions the variations in RF parameters of accelerating structures needs to be controlled precisely, hence low level RF feedback control system plays vital role. Considering revolutionary development in the field of digital electronics and inherent advantages of digital systems, digital LLRF control system work was taken up. The digital LLRF system consists of two major units namely RF processing and digital processing. RF processing unit uses I/Q modulator for amplitude and phase control. This unit provides synchronized clock using ÷16 pre-scalar and also performs up conversion and down conversion for synchronized LO and IF generation respectively, along with required amplification and filtering. Digital processing unit takes down converted IF signal with appropriate sampling rate for I/Q detection. To extract the amplitude and phase information I/Q data is digitally filtered and processed using CORDIC algorithm in FPGA. I/Q modulator is used for controlling the amplitude and phase of RF field. Prototype development of digital LLRF control system for 325 MHz, 650 MHz is in progress. Digital LLRF system at 505 MHz has been installed in one RF station of Indus-2 RF system. In this paper development of prototype Digital LLRF system at RFSD, Raja Ramanna Centre for Advanced Technology and results are presented. (author)

  14. Basic digital signal processing

    CERN Document Server

    Lockhart, Gordon B

    1985-01-01

    Basic Digital Signal Processing describes the principles of digital signal processing and experiments with BASIC programs involving the fast Fourier theorem (FFT). The book reviews the fundamentals of the BASIC program, continuous and discrete time signals including analog signals, Fourier analysis, discrete Fourier transform, signal energy, power. The text also explains digital signal processing involving digital filters, linear time-variant systems, discrete time unit impulse, discrete-time convolution, and the alternative structure for second order infinite impulse response (IIR) sections.

  15. Software Unit Testing during the Development of Digital Reactor Protection System of HTR-PM

    International Nuclear Information System (INIS)

    Guo Chao; Xiong Huasheng; Li Duo; Zhou Shuqiao; Li Jianghai

    2014-01-01

    Reactor Protection System (RPS) of High Temperature Gas-Cooled Reactor - Pebble bed Module (HTR-PM) is the first digital RPS designed and to be operated in the Nuclear Power Plant (NPP) of China, and its development process has receives a lot of concerns around the world. As a 1E-level safety system, the RPS has to be designed and developed following a series of nuclear laws and technical disciplines including software verification and validation (software V&V). Software V&V process demonstrates whether all stages during the software development are performed correctly, completely, accurately, and consistently, and the results of each stage are testable. Software testing is one of the most significant and time-consuming effort during software V&V. In this paper, we give a comprehensive introduction to the software unit testing during the development of RPS in HTR-PM. We first introduce the objective of the testing for our project in the aspects of static testing, black-box testing, and white-box testing. Then the testing techniques, including static testing and dynamic testing, are explained, and the testing strategy we employed is also introduced. We then introduce the principles of three kinds of coverage criteria we used including statement coverage, branch coverage, and the modified condition/decision coverage. As a 1E-level safety software, testing coverage needs to be up to 100% mandatorily. Then we talk the details of safety software testing during software development in HTR-PM, including the organization, methods and tools, testing stages, and testing report. The test result and experiences are shared and finally we draw a conclusion for the unit testing process. The introduction of this paper can contribute to improve the process of unit testing and software development for other digital instrumentation and control systems in NPPs. (author)

  16. Manufacture of Platform Prototype for Digital Safety System

    International Nuclear Information System (INIS)

    Lee, S. Y.; Kim, J. S.; Kim, J. M.

    2010-01-01

    Unit controller is a basic unit of digital safety system platform prototype. The typical unit controller is comprised of CPB(CPU board), CMB(communication board), AIB(Analog input board), AOB(Analog output board), CIB(contact input board), COB(contact output board), and a subrack. It is developed according to H/W development procedure and S/W development life cycle. A digital safety system(for example, plant protection system) is the assemblies of unit controllers. CPB performs the function of each system. DSP(digital signal processor) is built in CPB. CMB is responsible for communication between unit controllers. NSD(Network Switching Device) exchanges data between the unit controllers. Each unit controller of the platform are connected to NSD through CMB. Reliability analyses on unit controller and NSD are performed. These reliability data are used as input of technical validation

  17. Mammographic and sonographic findings of steatocystoma multiplex presenting as breast lumps.

    Science.gov (United States)

    Wan, John Mun Chin; Wong, Jill Su Lin; Tee, Shang-Ian

    2012-12-01

    Steatocystoma multiplex (SM) is an uncommon cutaneous disorder characterised by multiple intradermal cysts distributed over the trunk and proximal extremities. This condition affects both genders and is often inherited as an autosomal dominant trait, although sporadic cases have been described. This report describes the mammographic and sonographic features of the cysts, which presented as breast lumps, for evaluation. The cysts appeared as numerous well-circumscribed, radiolucent nodules with thin radiodense rims on mammography. On sonography, the cysts could be hypoechoic, isoechoic or demonstrate mixed echoes containing debris-fluid levels, depending on the amount of clear oily liquid and keratinous material. SM can be diagnosed based on a clinical setting of multiple asymptomatic small intradermal nodules over the trunk and proximal extremities, positive family history and imaging findings.

  18. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  19. EnviroAtlas - Average Direct Normal Solar resources kWh/m2/Day by 12-Digit HUC for the Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — The annual average direct normal solar resources by 12-Digit Hydrologic Unit (HUC) was estimated from maps produced by the National Renewable Energy Laboratory for...

  20. Mammographic features of isolated tuberculous mastitis.

    Science.gov (United States)

    Al-Marri, Mohammed R; Aref, Essam; Omar, Ahamed J

    2005-04-01

    To present the mammography findings in 8 patients with tuberculosis (TB) of the breast, with a review of the literature. This study is a retrospective data collection. Each chart with confirmed breast TB based on bacteriology or pathologic findings was analyzed for clinical presentation, gender, nationality, demographic data, prior history of TB, investigation, management, mammographic findings and ultrasound, when available. Mammograms were reviewed by 2 consultant radiologists without knowing the previous diagnosis or the nature of the study. The study was carried out at The State Tuberculosis Registry and Radiology Department, Hamad General Hospital, State of Qatar, from 1990 to 2002. Out of 13 females with TB mastitis, only 8 cases had mammograms preoperatively. The incidence of breast TB in Qatar is rare (1/1000 mammograms per year). Three types of TB mastitis were identified in our study; the nodular (50%), the diffuse (37.5%) of which 77% were limited to one sector of the breast and the sclerosing (12.5%) mastitis. Three patients (43%) were reported as carcinoma. Although mammography identified 3 types of TB, it was not helpful in differentiating TB from carcinoma of the breast. However, the careful evaluation of the degree of density and trabecular thickening of the mass in relation to it size might reduce the number of false positive cases of carcinoma diagnosed with mammograms. Biopsy specimen remains the best diagnostic tool in TB mastitis.

  1. Mammographic features of screening detected pT1 (a–b) invasive breast cancer using BI-RADS lexicon

    Energy Technology Data Exchange (ETDEWEB)

    Bargalló, Xavier, E-mail: xbarga@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain); Santamaría, Gorane, E-mail: gsanta@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain); Velasco, Martín, E-mail: mvelasco@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain); Amo, Montse del, E-mail: mdelamo@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain); Arguis, Pedro, E-mail: parguis@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain); Burrel, Marta, E-mail: mburrel@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain); Capurro, Sebastian, E-mail: scapurro@clinic.ub.es [Department of Radiology (CDIC), Hospital Clínic de Barcelona, C/Villarroel, 170, 08036 Barcelona (Spain)

    2012-10-15

    Aim: To describe mammographic features in screening detected invasive breast cancer less than or equal to 10 mm using Breast Imaging Reporting and Data System lexicon in full-field digital mammography. Patients and methods: A retrospective analysis of 123 pT1 (a–b) invasive breast cancers in women aged 50–69 years from our screening program. Radiologic patterns were: masses, calcifications, distortions, asymmetries and mixed. Masses: shape, margins and density, and calcifications: morphology, number of flecks and size of the cluster were taken into account, following Breast Imaging Reporting and Data System terminology. Results: We found 61 masses (49.6%), 8 masses with calcifications (6.5%), 30 groups of calcifications (24.4%), 19 architectural distortions (15.4%), 1 architectural distortion with calcifications (0.8%), 4 asymmetries (3.2%). Sixty out of 69 masses were irregular in shape, 6 lobular, 2 ovals and 1 round. Thirty-four showed ill-defined margins, 29 spiculated and 6 microlobulated. Most of them showed a density similar to surrounding fibroglandular tissue. Calcifications were pleomorphic or fine linear in 24 of 30 (80%). Most of cases showed more than 10 flecks and a size greater than 1 cm. Conclusion: The predominant radiologic finding is an irregular, isodense mass those margins tend to share different descriptors, being ill-defined margins the most constant finding. Calcifications representing invasive cancer are predominantly pleomorphic with more than 10 flecks per cm. Architectural distortion and invasive tubular carcinoma are more common than reported in general series.

  2. Mammographic features of screening detected pT1 (a–b) invasive breast cancer using BI-RADS lexicon

    International Nuclear Information System (INIS)

    Bargalló, Xavier; Santamaría, Gorane; Velasco, Martín; Amo, Montse del; Arguis, Pedro; Burrel, Marta; Capurro, Sebastian

    2012-01-01

    Aim: To describe mammographic features in screening detected invasive breast cancer less than or equal to 10 mm using Breast Imaging Reporting and Data System lexicon in full-field digital mammography. Patients and methods: A retrospective analysis of 123 pT1 (a–b) invasive breast cancers in women aged 50–69 years from our screening program. Radiologic patterns were: masses, calcifications, distortions, asymmetries and mixed. Masses: shape, margins and density, and calcifications: morphology, number of flecks and size of the cluster were taken into account, following Breast Imaging Reporting and Data System terminology. Results: We found 61 masses (49.6%), 8 masses with calcifications (6.5%), 30 groups of calcifications (24.4%), 19 architectural distortions (15.4%), 1 architectural distortion with calcifications (0.8%), 4 asymmetries (3.2%). Sixty out of 69 masses were irregular in shape, 6 lobular, 2 ovals and 1 round. Thirty-four showed ill-defined margins, 29 spiculated and 6 microlobulated. Most of them showed a density similar to surrounding fibroglandular tissue. Calcifications were pleomorphic or fine linear in 24 of 30 (80%). Most of cases showed more than 10 flecks and a size greater than 1 cm. Conclusion: The predominant radiologic finding is an irregular, isodense mass those margins tend to share different descriptors, being ill-defined margins the most constant finding. Calcifications representing invasive cancer are predominantly pleomorphic with more than 10 flecks per cm. Architectural distortion and invasive tubular carcinoma are more common than reported in general series

  3. Digital Authenticity and Integrity: Digital Cultural Heritage Documents as Research Resources

    Science.gov (United States)

    Bradley; Rachael

    2005-01-01

    This article presents the results of a survey addressing methods of securing digital content and ensuring the content's authenticity and integrity, as well as the perceived importance of authenticity and integrity. The survey was sent to 40 digital repositories in the United States and Canada between June 30 and July 19, 2003. Twenty-two…

  4. Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization--a laboratory study.

    Science.gov (United States)

    Keul, Christine; Stawarczyk, Bogna; Erdelt, Kurt-Jürgen; Beuer, Florian; Edelhoff, Daniel; Güth, Jan-Frederik

    2014-04-01

    To analyse the marginal fit of 4-unit fixed dental prostheses (FDPs) and the accuracy of three-dimensional cast-datasets using both approaches to Computer Aided Design (CAD)/Computer Aided Manufacturing (CAM): direct and indirect digitalization. A titanium model of a 4-unit FDP was digitized by an intraoral scanning device (iTero, Align Technology, Carlstadt, US; DD, n=12). Additionally 12 conventional impressions were taken and referring master casts were digitized by a laboratory scanner (CS2, Straumann, Basel, Switzerland; ID, n=12). Frameworks were fabricated (CARES CADCAM GmbH, Straumann, Markkleeberg, Germany) from base metal alloy (coron, Straumann; DD-C: n=12; ID-C: n=12) and zirconia (zerion, Straumann; DD-Z: n=12; ID-Z: n=12) from the same datasets. The marginal fit of the resulting frameworks and the accuracy of the underlying datasets from DD and ID were evaluated. Data were analyzed by unpaired two sample Student's t-test with Levene-test (pdigitalization methods (DD-Z: 127.23±66.87 μm, ID-Z: 141.08±193.17 μm) could be observed. Base metal alloy frameworks exhibited significantly better marginal fit than zirconia frameworks (DD: pdigitalization lead to clinically acceptable marginal fit of 4-unit FDPs from base metal alloy and zirconia. Higher accuracy of datasets from DD leads to better marginal fit of frameworks from base metal alloy but not for ones from zirconia. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  5. Minimal impact of adjuvant exemestane or tamoxifen treatment on mammographic breast density in postmenopausal breast cancer patients: A Dutch TEAM trial analysis

    NARCIS (Netherlands)

    J.G.H. van Nes; L.V. Beex (Louk); C.M. Seynaeve (Caroline); H. Putter (Hein); A. Sramek (Alexandr); S. Lardenoije (Susanne); M.D.-D.E. Carpentier (Marjolijn Duijm-D.E.); I. Van Rongen (Inge); J.W.R. Nortier (Johan W. R.); H.M. Zonderland (Harmine); C.J.H. van de Velde (Cornelis)

    2015-01-01

    textabstractBackground. Mammographic breast density is one of the strongest independent risk factors for developing breast cancer. We examined the effect of exemestane and tamoxifen on breast density in Dutch postmenopausal early breast cancer patients participating in the Tamoxifen Exemestane

  6. Analogue to digital upgrade project-boiler feedwater control system for Bruce Power nuclear units 1 & 2

    International Nuclear Information System (INIS)

    Long, R.

    2012-01-01

    Bruce Power Nuclear Generating Station A, “Bruce A” is in the final stages of its Restart Project. This capital project will see a large scale rehabilitation of Units 1 and 2 resulting in addition of 1500MW of safe, reliable, clean electricity to the Ontario grid. Restart Project Scope 375, Boiler Feedwater Controls Upgrade was sanctioned to replace obsolete analog devices with a modern digital control system. This project replaced the existing Foxboro H Line analog controls which comprised of 81 individual control modules and support instrumentation. The replacement system was a Triconex Triple Modular Redundant PLC which interfaces with two redundant touch screen monitors. The upgraded digital system incorporates the following controls: 1. Boiler Level Control Loops 2. Dearator Level Control Loops 3. Dearator Pressure Control Loops 4. Boiler Feedwater Recirculation Flow Control Loops A number of technical challenges were addressed when installing a new digital system within the existing plant configuration. Interfaces to new, old and refurbished field devices must be understood as well as implications of connecting to the plant’s Digital Control Computers (DCC’s) and newly installed Steam Generators. The overall project involved many stakeholders to address various requirements from conceptual / design stage through procurement, construction, commissioning and return to service. In addition, the project highlighted the unique requirements found in Nuclear Industry with respect to Human Factors and Software Quality Assurance. (author)

  7. Evaluation of the optimum region for mammographic system using computer simulation to study modulation transfer functions

    International Nuclear Information System (INIS)

    Oliveira, Isaura N. Sombra; Schiable, Homero; Porcel, Naider T.; Frere, Annie F.; Marques, Paulo M.A.

    1996-01-01

    An investigation of the 'optimum region' of the radiation field considering mammographic systems is studied. Such a region was defined in previous works as the field range where the system has its best performance and sharpest images. This study is based on a correlation of two methods for evaluating radiologic imaging systems, both using computer simulation in order to determine modulation transfer functions (MTFs) due to the X-ray tube focal spot in several field orientation and locations

  8. Breast nodules detection in images of ultrasonographic and mammographic simulators; Deteccao de nodulos mamarios em imagens de simuladores ultrassonografico e mamografico

    Energy Technology Data Exchange (ETDEWEB)

    Marcomini, Karem D.; Schiabel, Homero, E-mail: karem.dm@usp.br [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Dept. de Engenharia Eletrica; Carneiro, Antonio Adilton O. [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica

    2013-08-15

    Due to the high incidence rate of breast cancer in women, many procedures have been developed to assist in the diagnosis and early detection. Mammography and ultrasonography stand out as the main breast imaging techniques. In this context, the schemes of computer-aided diagnosis have provided to the specialist a more accurate and reliable second opinion by minimizing the visual subjectivity inter-observer. Thus, we propose the application of an automated method of segmentation, through the neural network SOM, to provide accurate information regarding the border of the lesion. The tests were employed in 100 mammographic images and 70 sonographic, both cases obtained by simulation. In order to verify the accuracy of the boundaries demarcated by the automatic detector, quantitative measurements were extracted to compare these images with the manually delineated by an experienced radiologist. The proposed technique presented high accuracy and sensitivity, and low error rate in correctly representing the mammographic and sonographic findings. (author)

  9. Age as a predictive factor of mammographic breast density in Jamaican women

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Deanne; Reid, Marvin; James, Michael

    2002-06-01

    AIM: We sought to determine the relationship between age, and other clinical characteristics such as parity, oestrogen use, dietary factors and menstrual history on breast density in Jamaican women. METHODS AND MATERIALS: A retrospective study was done of 891 patients who attended the breast imaging unit. The clinical characteristics were extracted from the patient records. Mammograms were assessed independently by two radiologists who were blinded to the patient clinical characteristics. Breast densities were assigned using the American College of Radiology (ACR) classification. RESULTS: The concordance between the ACR classification of breast density between the two independent radiologists was 92% with k = 0.76 (SE = 0.02, P < 0.001). Women with low breast density were heavier (81.3 {+-} 15.5 kg vs 68.4 {+-} 14.3 kg,P < 0.0001, mean {+-} standard deviation (SD)) and more obese (body mass index (BMI), 30.3 {+-} 5.8 kg m{sup -2} vs 26.0 {+-} 5.2 kg m{sup -2}, P < 0.0001). Mammographic breast density decreased with age. The age adjusted odds ratios (ORs) for predictors significantly related to high breast density were parity, OR = 0.79 (95%CI:0.71, 0.88), weight, OR = 0.92 (95% CI:0.91, 0.95), BMI, OR = 0.83 (95% CI:0.78, 0.89), menopause, OR = 0.51 (95% CI:0.36, 0.74) and a history of previous breast surgery, OR 1.6 (95% CI:1.1, 2.3). CONCLUSION: The rate decline of breast density with age in our population was influenced by parity and body composition. Soares, D. et al. (2002)

  10. Digitization of Microfilm: A Scottish Perspective.

    Science.gov (United States)

    Lauder, John

    1995-01-01

    Discusses the Scottish Newspapers Microfilming Unit's interest in conversion of microfilm to digital technology. Concerns include cost, potential market, reliability of digital technology as a preservation medium, and the necessity to have both microfilm and digital formats for preservation. Solicits feedback and information from colleagues on the…

  11. Application of Digital Technology for the Plant Protection System in Ulchin Nuclear Power Plant Units 5 and 6

    International Nuclear Information System (INIS)

    Deucksoo, Lee; Insik, Kim

    2006-01-01

    Since the completion of construction of Ulchin Nuclear Power Plant Units 3 and 4 (UCN 3 and 4), the first units of the OPR (Optimized Power Reactor) series, various advanced design features have been incorporated to the following OPRs. The Ulchin Nuclear Power Plant Units 5 and 6(UCN 5 and 6) which started commercial operation in Korea from 2004 and 2005 respectively, are designed to provide improvements in safety, reliability and costs by applying both advanced proven technology and experiences gained from the construction and operation of the previous OPRs. Among those improvements, the digital plant protection system (DPPS) and the digital engineered safety feature actuation system (DESFAS) are the key elements to the UCN 5 and 6 designs. The DPPS and DESFAS utilizing the digital computer technology offer a solution to the obsolescence problem of analog system. These features also provide the potential for additional benefits such as ease of maintenance, increased performance, reduction of internal and external cross channel wiring, improvement of the surveillance testability and flexibility of control logic programming change. During the initial design stage, the Korean regulatory body had evaluated these design concepts intensively and concluded it to be acceptable for the safety point of view. Also, in-depth review on the detailed design and the special evaluation/audit for the software design process has been performed to secure the quality of the software. As a result, every issue raised during licensing review has been clarified and the operating licenses for the UCN 5 and 6 were issued in October, 2003 and October, 2004 respectively, by the government. In this paper, design characteristics of the UCN 5 and 6 are introduced, and advanced design features and implementation process are presented focused on the DPPS/DESFAS with some benefit analysis results. (authors)

  12. Mammographic detection of breast arterial calcification as an independent predictor of coronary atherosclerotic disease in a single ethnic cohort of African American women

    NARCIS (Netherlands)

    Newallo, Domnique; Meinel, Felix G.; Schoepf, U. Joseph; Baumann, Stefan; De Cecco, Carlo N.; Leddy, Rebecca J.; Vliegenthart, Rozemarijn; Moellmann, Helge; Hamm, Christian W.; Morris, Pamela B.; Renker, Matthias

    Objective: Accumulating data on predominantly Caucasian women suggests an association between breast arterial calcification (BAC) and coronary artery disease (CAD). We sought to comprehensively examine the correlation between mammographic BAC and CAD endpoints detected by cardiac computed tomography

  13. Mammographic image restoration using maximum entropy deconvolution

    International Nuclear Information System (INIS)

    Jannetta, A; Jackson, J C; Kotre, C J; Birch, I P; Robson, K J; Padgett, R

    2004-01-01

    An image restoration approach based on a Bayesian maximum entropy method (MEM) has been applied to a radiological image deconvolution problem, that of reduction of geometric blurring in magnification mammography. The aim of the work is to demonstrate an improvement in image spatial resolution in realistic noisy radiological images with no associated penalty in terms of reduction in the signal-to-noise ratio perceived by the observer. Images of the TORMAM mammographic image quality phantom were recorded using the standard magnification settings of 1.8 magnification/fine focus and also at 1.8 magnification/broad focus and 3.0 magnification/fine focus; the latter two arrangements would normally give rise to unacceptable geometric blurring. Measured point-spread functions were used in conjunction with the MEM image processing to de-blur these images. The results are presented as comparative images of phantom test features and as observer scores for the raw and processed images. Visualization of high resolution features and the total image scores for the test phantom were improved by the application of the MEM processing. It is argued that this successful demonstration of image de-blurring in noisy radiological images offers the possibility of weakening the link between focal spot size and geometric blurring in radiology, thus opening up new approaches to system optimization

  14. Fast transient digitizer

    International Nuclear Information System (INIS)

    Villa, F.

    1982-01-01

    Method and apparatus for sequentially scanning a plurality of target elements with an electron scanning beam modulated in accordance with variations in a high-frequency analog signal to provide discrete analog signal samples representative of successive portions of the analog signal; coupling the discrete analog signal samples from each of the target elements to a different one of a plurality of high speed storage devices; converting the discrete analog signal samples to equivalent digital signals; and storing the digital signals in a digital memory unit for subsequent measurement or display

  15. Association of infertility and fertility treatment with mammographic density in a large screening-based cohort of women: a cross-sectional study.

    Science.gov (United States)

    Lundberg, Frida E; Johansson, Anna L V; Rodriguez-Wallberg, Kenny; Brand, Judith S; Czene, Kamila; Hall, Per; Iliadou, Anastasia N

    2016-04-13

    Ovarian stimulation drugs, in particular hormonal agents used for controlled ovarian stimulation (COS) required to perform in vitro fertilization, increase estrogen and progesterone levels and have therefore been suspected to influence breast cancer risk. This study aims to investigate whether infertility and hormonal fertility treatment influences mammographic density, a strong hormone-responsive risk factor for breast cancer. Cross-sectional study including 43,313 women recruited to the Karolinska Mammography Project between 2010 and 2013. Among women who reported having had infertility, 1576 had gone through COS, 1429 had had hormonal stimulation without COS and 5958 had not received any hormonal fertility treatment. Percent and absolute mammographic densities were obtained using the volumetric method Volpara™. Associations with mammographic density were assessed using multivariable generalized linear models, estimating mean differences (MD) with 95 % confidence intervals (CI). After multivariable adjustment, women with a history of infertility had 1.53 cm(3) higher absolute dense volume compared to non-infertile women (95 % CI: 0.70 to 2.35). Among infertile women, only those who had gone through COS treatment had a higher absolute dense volume than those who had not received any hormone treatment (adjusted MD 3.22, 95 % CI: 1.10 to 5.33). No clear associations were observed between infertility, fertility treatment and percent volumetric density. Overall, women reporting infertility had more dense tissue in the breast. The higher absolute dense volume in women treated with COS may indicate a treatment effect, although part of the association might also be due to the underlying infertility. Continued monitoring of cancer risk in infertile women, especially those who undergo COS, is warranted.

  16. Circulating insulin-like growth factor-I, insulin-like growth factor binding protein-3 and terminal duct lobular unit involution of the breast: a cross-sectional study of women with benign breast disease.

    Science.gov (United States)

    Horne, Hisani N; Sherman, Mark E; Pfeiffer, Ruth M; Figueroa, Jonine D; Khodr, Zeina G; Falk, Roni T; Pollak, Michael; Patel, Deesha A; Palakal, Maya M; Linville, Laura; Papathomas, Daphne; Geller, Berta; Vacek, Pamela M; Weaver, Donald L; Chicoine, Rachael; Shepherd, John; Mahmoudzadeh, Amir Pasha; Wang, Jeff; Fan, Bo; Malkov, Serghei; Herschorn, Sally; Hewitt, Stephen M; Brinton, Louise A; Gierach, Gretchen L

    2016-02-18

    Terminal duct lobular units (TDLUs) are the primary structures from which breast cancers and their precursors arise. Decreased age-related TDLU involution and elevated mammographic density are both correlated and independently associated with increased breast cancer risk, suggesting that these characteristics of breast parenchyma might be linked to a common factor. Given data suggesting that increased circulating levels of insulin-like growth factors (IGFs) factors are related to reduced TDLU involution and increased mammographic density, we assessed these relationships using validated quantitative methods in a cross-sectional study of women with benign breast disease. Serum IGF-I, IGFBP-3 and IGF-I:IGFBP-3 molar ratios were measured in 228 women, ages 40-64, who underwent diagnostic breast biopsies yielding benign diagnoses at University of Vermont affiliated centers. Biopsies were assessed for three separate measures inversely related to TDLU involution: numbers of TDLUs per unit of tissue area ("TDLU count"), median TDLU diameter ("TDLU span"), and number of acini per TDLU ("acini count"). Regression models, stratified by menopausal status and adjusted for potential confounders, were used to assess the associations of TDLU count, median TDLU span and median acini count per TDLU with tertiles of circulating IGFs. Given that mammographic density is associated with both IGF levels and breast cancer risk, we also stratified these associations by mammographic density. Higher IGF-I levels among postmenopausal women and an elevated IGF-I:IGFBP-3 ratio among all women were associated with higher TDLU counts, a marker of decreased lobular involution (P-trend = 0.009 and breast cancer risk. If confirmed in prospective studies with cancer endpoints, these data may suggest that evaluation of IGF signaling and its downstream effects may have value for risk prediction and suggest strategies for breast cancer chemoprevention through inhibition of the IGF system.

  17. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    Science.gov (United States)

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  18. Mammographic and sonographic findings of unilateral breast edema in congestive heart failure : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung; Lee, Seung Koo; Oh, Ki Keun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-06-01

    Unilateral breast edema has many causes, though among these, congestive heart failure is rare. We report mammographic and sonographic findings of unilateral breast edema due to congestive heart failure. Mammography showed diffuse increase density and skin thickening but no evidence of mass or calcification. Ultrasonography showed skin thickening and increased echogenicity in the subcutaneous fat layer, while in the dermal layer, with tubular and reticular anechoic structures suggestive of dilated lymphatics were seen. After treatment of the heart failure, resolution of the abnormalities seen on mammogram established that these were secondary findings.

  19. Mammographic and sonographic findings of unilateral breast edema in congestive heart failure : a case report

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Lee, Seung Koo; Oh, Ki Keun

    1997-01-01

    Unilateral breast edema has many causes, though among these, congestive heart failure is rare. We report mammographic and sonographic findings of unilateral breast edema due to congestive heart failure. Mammography showed diffuse increase density and skin thickening but no evidence of mass or calcification. Ultrasonography showed skin thickening and increased echogenicity in the subcutaneous fat layer, while in the dermal layer, with tubular and reticular anechoic structures suggestive of dilated lymphatics were seen. After treatment of the heart failure, resolution of the abnormalities seen on mammogram established that these were secondary findings

  20. Mammographic features of isolated tuberculous mastitis

    International Nuclear Information System (INIS)

    Al-Marri, Mohammed R.; Aref, Essam; Omar, Ahamed J.

    2005-01-01

    To present the mammography findings in 8 patients with tuberculosis (TB) of the breast, with a review of the literature. This study is a retrospective data collection. Each chart with confirmed breast TB based on bacteriology or pathologic findings was analyzed for clinical presentation, gender, nationality, demographic data, prior history of TB, investigation, management, mammographic findings and ultrasound, when available. Mammograms were reviewed by 2 consultant radiologists without knowing the previous diagnosis or the nature of the study. The study was carried out at The State Tuberculosis Registry and Radiology Department, Hamad General Hospital, State of Qatar, from 1990 to 2002. Out of 13 females with TB mastitis, only 8 cases had mammograms preoperatively. The incidence of breast TB in Qatar is rare (1/1000 mammograms per year). Three types of TB mastitis were identified in our study; the nodular (50%), the diffuse (37.5%) of which 77% were limited to one sector of the breast and the sclerosing (12.5%) mastitis. Three patients (43%) were reported as carcinoma. Although mammography identified 3 types of TB, it was not helpful in differentiating TB from carcinoma of the breast. However, the careful evaluation of the degree of density and trabecular thickening of the mass in relation to it size might reduce the number of false positive cases of carcinoma diagnosed with mammograms. Biopsy specimen remains the best diagnostic tool in TB mastitis. (author)

  1. Quantitative breast density analysis using tomosynthesis and comparison with MRI and digital mammography.

    Science.gov (United States)

    Moon, Woo Kyung; Chang, Jie-Fan; Lo, Chung-Ming; Chang, Jung Min; Lee, Su Hyun; Shin, Sung Ui; Huang, Chiun-Sheng; Chang, Ruey-Feng

    2018-02-01

    Breast density at mammography has been used as markers of breast cancer risk. However, newly introduced tomosynthesis and computer-aided quantitative method could provide more reliable breast density evaluation. In the experiment, 98 tomosynthesis image volumes were obtained from 98 women. For each case, an automatic skin removal was used and followed by a fuzzy c-mean (FCM) classifier which separated the fibroglandular tissues from other tissues in breast area. Finally, percent of breast density and breast volume were calculated and the results were compared with MRI. In addition, the percent of breast density and breast area of digital mammography calculated using the software Cumulus (University of Toronto, Toronto, ON, Canada.) were also compared with 3-D modalities. Percent of breast density and breast volume, which were computed from tomosynthesis, MRI and digital mammography were 17.37% ± 4.39% and 607.12 cm 3  ± 323.01 cm 3 , 20.3% ± 8.6% and 537.59 cm 3  ± 287.74 cm 3 , and 12.03% ± 4.08%, respectively. There were significant correlations on breast density as well as volume between tomosynthesis and MRI (R = 0.482 and R = 0.805), tomosynthesis and breast density with breast area of digital mammography (R = 0.789 and R = 0.877), and MRI and breast density with breast area of digital mammography (R = 0.482 and R = 0.857) (all P values density and breast volume evaluated from tomosynthesis, MRI and breast density and breast area of digital mammographic images have significant correlations and indicate that tomosynthesis could provide useful 3-D information on breast density through proposed method. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Fast digital recorders of signal shaping

    International Nuclear Information System (INIS)

    Meleshko, E.A.

    1997-01-01

    Methodology of fast digital registration and pulse signals through fast-action analog-to-digital converters is considered. Systems of digital recorders: sampling and storage devices and operational memory units are described. Main attention is paid to developing parallel analog-to-digital converters, making it possible to bring the conversion frequencies up to several gigahertzes are described. Parallel-sequential analog-to-digital converters, combining high action with increased accuracy are also considered. Concrete examples of designing universal and specialized digital signal recorders, applied in experimental physics, are presented. 44 refs., 12 figs

  3. EnviroAtlas - Manure application to agricultural lands from confined animal feeding operations by 12-digit HUC for the Conterminous United States, 2006

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas dataset contains data on the mean livestock manure application to cultivated crop and hay/pasture lands by 12-digit Hydrologic Unit (HUC) in 2006....

  4. Image quality and dose in mammographic images obtained in Mexico City hospitals

    International Nuclear Information System (INIS)

    Ruiz-Trejo, C.; Brandan, M.-E.; Verdejo, M.; Flores, A.; Guevara, M.; Martin, J.; Madero-Preciado, L.

    2001-01-01

    The performance of three mammographic systems in large Mexican hospitals has been evaluated, as well as the image quality and associated dose. Quality control tests include examination of X-ray equipment, darkroom conditions, film processor, and viewboxes. Systems referred to as '1', '2', and '3' passed 50%, 75% and 75% of these tests, respectively. Quality image is assessed using five images obtained under similar nominal conditions in each X-ray equipment. System 1 generates no image of acceptable quality, while equipment 2 and 3 produce one and two, respectively. The mean glandular dose for the best images obtained in each service with an accreditation phantom has been measured, and the values are 1.4 mGy, 1.6 mGy, and 1.0 mGy, respectively. (author)

  5. Cigarette smoking and mammographic density in the Danish Diet, Cancer and Health cohort.

    Science.gov (United States)

    Jacobsen, Katja Kemp; Lynge, Elsebeth; Vejborg, Ilse; Tjønneland, Anne; von Euler-Chelpin, My; Andersen, Zorana J

    2016-02-01

    Smoking before first childbirth increases breast cancer risk, but the biological mechanism remains unknown and may involve mammographic density (MD), one of the strongest biomarkers of breast cancer risk. We aimed to examine whether active smoking and passive smoking were associated with MD. For the 5,356 women (4,489 postmenopausal) from the Danish Diet, Cancer and Health cohort (1993-1997) who attended mammographic screening in Copenhagen (1993-2001), we used MD (mixed/dense or fatty) assessed at the first screening after cohort entry. Active smoking (status, duration, and intensity) and passive smoking were assessed at cohort baseline (1993-1997) via questionnaire, together with other breast cancer risk factors. Logistic regression was used to estimate associations (odds ratios, 95 % confidence intervals) between smoking and MD, adjusting for confounders. Two thousand and twenty-six (56.5 %) women had mixed/dense MD, 2,214 (41.4 %) were current, and 1,175 (21.9 %) former smokers. Current smokers had significantly lower odds (0.86, 0.75-0.99) of having mixed/dense MD compared to never smokers, while former smoking was not associated with MD. Inverse association between smoking and MD was strongest in women who initiated smoking before age of 16 years (0.79, 0.64-0.96), smoked ≥15 cigarettes/day (0.83, 0.71-0.98), smoked ≥5 pack-years (0.62, 0.43-0.89), smoked >30 years (0.86, 0.75-0.99), and smoked ≥11 years before first childbirth (0.70, 0.51-0.96). Association between smoking and MD diminished after smoking cessation, with increased odds of having mixed/dense breasts in women who quit smoking >20 years ago as compared to current smokers (1.37, 1.01-1.67). There was no association between passive smoking and MD. We found an inverse association between active smoking and MD.

  6. Detecting mammographically occult cancer in women with dense breasts using Radon Cumulative Distribution Transform: a preliminary analysis

    Science.gov (United States)

    Lee, Juhun; Nishikawa, Robert M.; Rohde, Gustavo K.

    2018-02-01

    We propose using novel imaging biomarkers for detecting mammographically-occult (MO) cancer in women with dense breast tissue. MO cancer indicates visually occluded, or very subtle, cancer that radiologists fail to recognize as a sign of cancer. We used the Radon Cumulative Distribution Transform (RCDT) as a novel image transformation to project the difference between left and right mammograms into a space, increasing the detectability of occult cancer. We used a dataset of 617 screening full-field digital mammograms (FFDMs) of 238 women with dense breast tissue. Among 238 women, 173 were normal with 2 - 4 consecutive screening mammograms, 552 normal mammograms in total, and the remaining 65 women had an MO cancer with a negative screening mammogram. We used Principal Component Analysis (PCA) to find representative patterns in normal mammograms in the RCDT space. We projected all mammograms to the space constructed by the first 30 eigenvectors of the RCDT of normal cases. Under 10-fold crossvalidation, we conducted quantitative feature analysis to classify normal mammograms and mammograms with MO cancer. We used receiver operating characteristic (ROC) analysis to evaluate the classifier's output using the area under the ROC curve (AUC) as the figure of merit. Four eigenvectors were selected via a feature selection method. The mean and standard deviation of the AUC of the trained classifier on the test set were 0.74 and 0.08, respectively. In conclusion, we utilized imaging biomarkers to highlight differences between left and right mammograms to detect MO cancer using novel imaging transformation.

  7. Evaluation of mean glandular dose in a full-field digital mammography unit in Tabriz (IR)

    International Nuclear Information System (INIS)

    Riabi, H. A.; Mehnati, P.; Mesbahi, A.

    2010-01-01

    This study was aimed at evaluating the mean glandular dose (MGD) and affecting factors during mammography examinations by a full-field digital mammography unit. An extensive quality control program was performed to assure that the unit is properly working. Required information including compressed breast thickness (CBT), breast parenchymal pattern and technical factors used for imaging were recorded. An entrance skin exposure measurement was also performed using slabs of polymethylmethacrylate with 2-8 cm thickness. On the basis of recorded information and measured data, the MGD was estimated for 1145 mammography examinations obtained from 298 patients. Mean CBTs of 4.9 and 5.8 cm and MGDs of 2 and 2.4 mGy were observed for cranio-caudal and medio-lateral oblique views, respectively. Significant correlation was seen between MGD and CBT, breast parenchymal pattern and applied kVp and mAs. (authors)

  8. Brachytherapy, diagnostic radiology, mammographic radiology and ophthalmic applicators. An assessment of current and future needs in the UK and the role of NPL

    International Nuclear Information System (INIS)

    Angliss, R.; Bass, G.; Sander, T.

    2001-01-01

    Several UK hospitals were visited by NPL staff to discuss the current practises and future developments in brachytherapy, diagnostic and mammographic radiology and ophthalmic applicators. The results of the discussions are presented here, including NPL's role in each of these areas is discussed. (author)

  9. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  10. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  11. Stereotaxic core needle biopsy of breast microcalcifications obtained using a standard mammography table with an add-on unit

    International Nuclear Information System (INIS)

    Ward, S.E.; Taves, D.H.; McCurdy, L.I.

    2000-01-01

    To demonstrate the reliability of stereotaxic biopsy of indeterminate microcalcifications using a standard mammography table with an add-on unit. In 121 cases of indeterminate microcalcifications, core biopsy was performed using a standard mammography table with an add-on stereotaxic unit. Microcalcifications were identified on radiography of core specimens. Microcalcifications and a definitive histologic diagnosis were obtained in 112 core biopsies (92.6%), with no significant complications. In 23 lesions frank malignancy was diagnosed, and all of these diagnoses were confirmed on surgery. Pathologic examination suggested carcinoma in 4 lesions, and open biopsy confirmed malignancy in 3 of these cases. Four lesions showed atypical ductal hyperplasia. Benign disease was diagnosed in 81 lesions, of which 78 remained stable on mammographic follow-up (mean 16 months later) and 3 were subjected to surgical biopsy (of which 1 was malignant and 2 were benign). Nine cases were technically unsatisfactory because microcalcifications were not sampled. Stereotaxic core biopsy performed with an add-on unit is a safe and reliable technique for biopsy of indeterminate microcalcifications. For successful biopsy, microcalcifications must be harvested. Pathologic results should be correlated with mammographic findings. The accuracy rate compares favourably with results reported using prone biopsy tables. In an era of cost containment, this alternative to prone biopsy tables could result m significant savings in terms of capital investment and use of hospital rooms. In this study, surgical biopsy could have been avoided in 64.5% of cases. (author)

  12. Human observer detection experiments with mammograms and power-law noise

    International Nuclear Information System (INIS)

    Burgess, Arthur E.; Jacobson, Francine L.; Judy, Philip F.

    2001-01-01

    We determined contrast thresholds for lesion detection as a function of lesion size in both mammograms and filtered noise backgrounds with the same average power spectrum, P(f )=B/f 3 . Experiments were done using hybrid images with digital images of tumors added to digitized normal backgrounds, displayed on a monochrome monitor. Four tumors were extracted from digitized specimen radiographs. The lesion sizes were varied by digital rescaling to cover the range from 0.5 to 16 mm. Amplitudes were varied to determine the value required for 92% correct detection in two-alternative forced-choice (2AFC) and 90% for search experiments. Three observers participated, two physicists and a radiologist. The 2AFC mammographic results demonstrated a novel contrast-detail (CD) diagram with threshold amplitudes that increased steadily (with slope of 0.3) with increasing size for lesions larger than 1 mm. The slopes for prewhitening model observers were about 0.4. Human efficiency relative to these models was as high as 90%. The CD diagram slopes for the 2AFC experiments with filtered noise were 0.44 for humans and 0.5 for models. Human efficiency relative to the ideal observer was about 40%. The difference in efficiencies for the two types of backgrounds indicates that breast structure cannot be considered to be pure random noise for 2AFC experiments. Instead, 2AFC human detection with mammographic backgrounds is limited by a combination of noise and deterministic masking effects. The search experiments also gave thresholds that increased with lesion size. However, there was no difference in human results for mammographic and filtered noise backgrounds, suggesting that breast structure can be considered to be pure random noise for this task. Our conclusion is that, in spite of the fact that mammographic backgrounds have nonstationary statistics, models based on statistical decision theory can still be applied successfully to estimate human performance

  13. Effects of Different Compression Techniques on Diagnostic Accuracies of Breast Masses on Digitized Mammograms

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Yanhui Yang; Dongdong Rong; Xinyu Y ao; Kuncheng Li

    2008-01-01

    Background: The JPEG 2000 compression technique has recently been introduced into the medical imaging field. It is critical to understand the effects of this technique on the detection of breast masses on digitized images by human observers. Purpose: To evaluate whether lossless and lossy techniques affect the diagnostic results of malignant and benign breast masses on digitized mammograms. Material and Methods: A total of 90 screen-film mammograms including craniocaudal and lateral views obtained from 45 patients were selected by two non-observing radiologists. Of these, 22 cases were benign lesions and 23 cases were malignant. The mammographic films were digitized by a laser film digitizer, and compressed to three levels (lossless and lossy 20:1 and 40:1) using the JPEG 2000 wavelet-based image compression algorithm. Four radiologists with 10-12 years' experience in mammography interpreted the original and compressed images. The time interval was 3 weeks for each reading session. A five-point malignancy scale was used, with a score of 1 corresponding to definitely not a malignant mass, a score of 2 referring to not a malignant mass, a score of 3 meaning possibly a malignant mass, a score of 4 being probably a malignant mass, and a score of 5 interpreted as definitely a malignant mass. The radiologists' performance was evaluated using receiver operating characteristic analysis. Results: The average Az values for all radiologists decreased from 0.8933 for the original uncompressed images to 0.8299 for the images compressed at 40:1. This difference was not statistically significant. The detection accuracy of the original images was better than that of the compressed images, and the Az values decreased with increasing compression ratio. Conclusion: Digitized mammograms compressed at 40:1 could be used to substitute original images in the diagnosis of breast cancer

  14. Evaluasi Tingkat Kesiapan Organisasi dalam Rangka Preservasi Digital (Studi Kasus Pada Unit Repositori Flinders Academic Commons Of Flinders University Library (FACFUL, Adelaide, Australia Selatan

    Directory of Open Access Journals (Sweden)

    Rattahpinnusa Haresariu Handisa

    2017-12-01

    Full Text Available Penelitian ini bertujuan mengidentifikasi tingkat kesiapan lembaga repositori dalam rangka preservasi digital pada Flinders Academic Commons Flinders University Library (FACFUL dan mengidentifikasi faktor-faktor yang berpengaruh terhadap tingkat kesiapan organisasi. Terdapat tiga aspek yang diteliti meliputi: kesiapan infrastruktur, kesiapan teknologi serta sumber daya yang dibutuhkan bagi preservasi digital. Penelitian ini menggunakan metode studi kasus dengan  intesity sampel. Adapun instrumen pengumpulan data menggunakan Cornell University Survey of Institutional Readiness Checklist. Selanjutnya, tehnik pengambilan data menggunakan tehnik wawancara dengan Ms. Liz-Walkley Hall selaku pustakawati yang bertanggung jawab terhadap unit repositori digital FACFUL. Adapun informasi penunjang diperoleh melalui studi kepustakaan merujuk pada website Perpustakaan Universitas  Flinders. Data yang terkumpul dianalisis secara deskriptif menggunakan indikator kesiapan organisasi Cornel University Model. Hasil penelitian menunjukkan bahwa unit repositori pada FACFUL kurang siap dalam menjalankan preservasi digital. Tingkat kesiapan organisasi Perpustakaan Universitas  Flinders dalam pelestarian digital berapa pada level terbawah yakni Acknowledgement . Pada tingkat tersebut, Perpustakaan Flinders masih dalam tahap pengembangan kesadaran tentang pentingnya preservasi digital. Selanjutnya, faktor-faktor yang mempengaruhi rendahnya tingkat kesiapan organisasi tersebut adalah tidak adanya pernyataan pentingya preservasi digital pada kebijakan pengembangan koleksi; keterbatasan pendanaan dan keterbatasan sumber daya manusia yang kompeten dalam preservasi digital. Penelitian ini merekomendasikan Perpustakaan Universitas Flinders untuk  melakukan uji kelayakan bagi preservasi digital. Salah satu model bisnis yang sesuai dengan kondisi Perpustakaan Universitas  Flinders adalah Meta Archive Model (MAM. Model tersebut berbasis komunitas bagi preservasi digital

  15. Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression.

    Science.gov (United States)

    Su, Ting-Shu; Sun, Jian

    2016-09-01

    For 20 years, the intraoral digital impression technique has been applied to the fabrication of computer aided design and computer aided manufacturing (CAD-CAM) fixed dental prostheses (FDPs). Clinical fit is one of the main determinants of the success of an FDP. Studies of the clinical fit of 3-unit ceramic FDPs made by means of a conventional impression versus a digital impression technology are limited. The purpose of this in vitro study was to evaluate and compare the internal fit and marginal fit of CAD-CAM, 3-unit ceramic FDP frameworks fabricated from an intraoral digital impression and a conventional impression. A standard model was designed for a prepared maxillary left canine and second premolar and missing first premolar. The model was scanned with an intraoral digital scanner, exporting stereolithography (STL) files as the experimental group (digital group). The model was used to fabricate 10 stone casts that were scanned with an extraoral scanner, exporting STL files to a computer connected to the scanner as the control group (conventional group). The STL files were used to produce zirconia FDP frameworks with CAD-CAM. These frameworks were seated on the standard model and evaluated for marginal and internal fit. Each framework was segmented into 4 sections per abutment teeth, resulting in 8 sections per framework, and was observed using optical microscopy with ×50 magnification. Four measurement points were selected on each section as marginal discrepancy (P1), mid-axial wall (P2), axio-occusal edge (P3), and central-occlusal point (P4). Mean marginal fit values of the digital group (64 ±16 μm) were significantly smaller than those of the conventional group (76 ±18 μm) (Pdigital group (111 ±34 μm) were significantly smaller than those of the conventional group (132 ±44 μm) (Pdigital and conventional impressions showed clinically acceptable marginal and internal fit. The marginal and internal fit of frameworks fabricated from the intraoral

  16. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  17. Towards a Disruptive Digital Platform Model

    DEFF Research Database (Denmark)

    Kazan, Erol

    that digital platforms leverage on three strategic design elements (i.e., business, architecture, and technology design) to create supportive conditions for facilitating disruption. To shed light on disruptive digital platforms, I opted for payment platforms as my empirical context and unit of analysis......Digital platforms are layered modular information technology architectures that support disruption. Digital platforms are particularly disruptive, as they facilitate the quick release of digital innovations that may replace established innovations. Yet, despite their support for disruption, we have...... not fully understood how such digital platforms can be strategically designed and configured to facilitate disruption. To that end, this thesis endeavors to unravel disruptive digital platforms from the supply perspective that are grounded on strategic digital platform design elements. I suggest...

  18. Cost-effectiveness of annual versus biennial screening mammography for women with high mammographic breast density.

    Science.gov (United States)

    Pataky, Reka; Ismail, Zahra; Coldman, Andrew J; Elwood, Mark; Gelmon, Karen; Hedden, Lindsay; Hislop, Greg; Kan, Lisa; McCoy, Bonnie; Olivotto, Ivo A; Peacock, Stuart

    2014-12-01

    The sensitivity of screening mammography is much lower among women who have dense breast tissue, compared with women who have largely fatty breasts, and they are also at much higher risk of developing the disease. Increasing mammography screening frequency from biennially to annually has been suggested as a policy option to address the elevated risk in this population. The purpose of this study was to assess the cost-effectiveness of annual versus biennial screening mammography among women aged 50-79 with dense breast tissue. A Markov model was constructed based on screening, diagnostic, and treatment pathways for the population-based screening and cancer care programme in British Columbia, Canada. Model probabilities and screening costs were calculated from screening programme data. Costs for breast cancer treatment were calculated from treatment data, and utility values were obtained from the literature. Incremental cost-effectiveness was expressed as cost per quality adjusted life year (QALY), and probabilistic sensitivity analysis was conducted. Compared with biennial screening, annual screening generated an additional 0.0014 QALYs (95% CI: -0.0480-0.0359) at a cost of $819 ($ = Canadian dollars) per patient (95% CI: 506-1185), resulting in an incremental cost effectiveness ratio of $565,912/QALY. Annual screening had a 37.5% probability of being cost-effective at a willingness-to-pay threshold of $100,000/QALY. There is considerable uncertainty about the incremental cost-effectiveness of annual mammography. Further research on the comparative effectiveness of screening strategies for women with high mammographic breast density is warranted, particularly as digital mammography and density measurement become more widespread, before cost-effectiveness can be reevaluated. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  19. Estimation of breast percent density in raw and processed full field digital mammography images via adaptive fuzzy c-means clustering and support vector machine segmentation

    International Nuclear Information System (INIS)

    Keller, Brad M.; Nathan, Diane L.; Wang Yan; Zheng Yuanjie; Gee, James C.; Conant, Emily F.; Kontos, Despina

    2012-01-01

    Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., “FOR PROCESSING”) and vendor postprocessed (i.e., “FOR PRESENTATION”), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which

  20. Breast tissue classification in digital breast tomosynthesis images using texture features: a feasibility study

    Science.gov (United States)

    Kontos, Despina; Berger, Rachelle; Bakic, Predrag R.; Maidment, Andrew D. A.

    2009-02-01

    Mammographic breast density is a known breast cancer risk factor. Studies have shown the potential to automate breast density estimation by using computerized texture-based segmentation of the dense tissue in mammograms. Digital breast tomosynthesis (DBT) is a tomographic x-ray breast imaging modality that could allow volumetric breast density estimation. We evaluated the feasibility of distinguishing between dense and fatty breast regions in DBT using computer-extracted texture features. Our long-term hypothesis is that DBT texture analysis can be used to develop 3D dense tissue segmentation algorithms for estimating volumetric breast density. DBT images from 40 women were analyzed. The dense tissue area was delineated within each central source projection (CSP) image using a thresholding technique (Cumulus, Univ. Toronto). Two (2.5cm)2 ROIs were manually selected: one within the dense tissue region and another within the fatty region. Corresponding (2.5cm)3 ROIs were placed within the reconstructed DBT images. Texture features, previously used for mammographic dense tissue segmentation, were computed. Receiver operating characteristic (ROC) curve analysis was performed to evaluate feature classification performance. Different texture features appeared to perform best in the 3D reconstructed DBT compared to the 2D CSP images. Fractal dimension was superior in DBT (AUC=0.90), while contrast was best in CSP images (AUC=0.92). We attribute these differences to the effects of tissue superimposition in CSP and the volumetric visualization of the breast tissue in DBT. Our results suggest that novel approaches, different than those conventionally used in projection mammography, need to be investigated in order to develop DBT dense tissue segmentation algorithms for estimating volumetric breast density.

  1. High mammographic density is associated with an increase in stromal collagen and immune cells within the mammary epithelium.

    Science.gov (United States)

    Huo, Cecilia W; Chew, Grace; Hill, Prue; Huang, Dexing; Ingman, Wendy; Hodson, Leigh; Brown, Kristy A; Magenau, Astrid; Allam, Amr H; McGhee, Ewan; Timpson, Paul; Henderson, Michael A; Thompson, Erik W; Britt, Kara

    2015-06-04

    Mammographic density (MD), after adjustment for a women's age and body mass index, is a strong and independent risk factor for breast cancer (BC). Although the BC risk attributable to increased MD is significant in healthy women, the biological basis of high mammographic density (HMD) causation and how it raises BC risk remain elusive. We assessed the histological and immunohistochemical differences between matched HMD and low mammographic density (LMD) breast tissues from healthy women to define which cell features may mediate the increased MD and MD-associated BC risk. Tissues were obtained between 2008 and 2013 from 41 women undergoing prophylactic mastectomy because of their high BC risk profile. Tissue slices resected from the mastectomy specimens were X-rayed, then HMD and LMD regions were dissected based on radiological appearance. The histological composition, aromatase immunoreactivity, hormone receptor status and proliferation status were assessed, as were collagen amount and orientation, epithelial subsets and immune cell status. HMD tissue had a significantly greater proportion of stroma, collagen and epithelium, as well as less fat, than LMD tissue did. Second harmonic generation imaging demonstrated more organised stromal collagen in HMD tissues than in LMD tissues. There was significantly more aromatase immunoreactivity in both the stromal and glandular regions of HMD tissues than in those regions of LMD tissues, although no significant differences in levels of oestrogen receptor, progesterone receptor or Ki-67 expression were detected. The number of macrophages within the epithelium or stroma did not change; however, HMD stroma exhibited less CD206(+) alternatively activated macrophages. Epithelial cell maturation was not altered in HMD samples, and no evidence of epithelial-mesenchymal transition was seen; however, there was a significant increase in vimentin(+)/CD45(+) immune cells within the epithelial layer in HMD tissues. We confirmed increased

  2. Development of Automatic Cluster Algorithm for Microcalcification in Digital Mammography

    International Nuclear Information System (INIS)

    Choi, Seok Yoon; Kim, Chang Soo

    2009-01-01

    Digital Mammography is an efficient imaging technique for the detection and diagnosis of breast pathological disorders. Six mammographic criteria such as number of cluster, number, size, extent and morphologic shape of microcalcification, and presence of mass, were reviewed and correlation with pathologic diagnosis were evaluated. It is very important to find breast cancer early when treatment can reduce deaths from breast cancer and breast incision. In screening breast cancer, mammography is typically used to view the internal organization. Clusterig microcalcifications on mammography represent an important feature of breast mass, especially that of intraductal carcinoma. Because microcalcification has high correlation with breast cancer, a cluster of a microcalcification can be very helpful for the clinical doctor to predict breast cancer. For this study, three steps of quantitative evaluation are proposed : DoG filter, adaptive thresholding, Expectation maximization. Through the proposed algorithm, each cluster in the distribution of microcalcification was able to measure the number calcification and length of cluster also can be used to automatically diagnose breast cancer as indicators of the primary diagnosis.

  3. Description and benefits of dynamic collimation in digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Popova, Y.; Hersemeule, G.; Klausz, R.; Souchay, H.

    2015-01-01

    X-ray field to image receptor active area alignment is usually tested in mammographic QC. In digital breast tomosynthesis (dBT), the source moves during the acquisition, generating a displacement of the X-ray beam edges relative to the detector, in or out of the detector active area. To minimise unnecessary radiation while maximising the useful field of view, a solution consisting in adjusting the collimation with the source rotation was implemented on the GE SenoClaire dBT system. This solution is described and tested using three different methods based on: (1) images from the detector, (2) a non-screen film and (3) a semiconductor tool providing the X-ray intensity profile. Method 1 demonstrated a maximum positioning error of 0.3 mm. Method 2 was found non-applicable; Method 3 provided measurements within 1.5 mm. Dynamic collimation enables maintaining an X-ray field to detector congruence comparable with 2D. Measuring the position of the X-ray field edges using a dedicated tool makes routine QC possible. (authors)

  4. Feature extraction using convolutional neural network for classifying breast density in mammographic images

    Science.gov (United States)

    Thomaz, Ricardo L.; Carneiro, Pedro C.; Patrocinio, Ana C.

    2017-03-01

    Breast cancer is the leading cause of death for women in most countries. The high levels of mortality relate mostly to late diagnosis and to the direct proportionally relationship between breast density and breast cancer development. Therefore, the correct assessment of breast density is important to provide better screening for higher risk patients. However, in modern digital mammography the discrimination among breast densities is highly complex due to increased contrast and visual information for all densities. Thus, a computational system for classifying breast density might be a useful tool for aiding medical staff. Several machine-learning algorithms are already capable of classifying small number of classes with good accuracy. However, machinelearning algorithms main constraint relates to the set of features extracted and used for classification. Although well-known feature extraction techniques might provide a good set of features, it is a complex task to select an initial set during design of a classifier. Thus, we propose feature extraction using a Convolutional Neural Network (CNN) for classifying breast density by a usual machine-learning classifier. We used 307 mammographic images downsampled to 260x200 pixels to train a CNN and extract features from a deep layer. After training, the activation of 8 neurons from a deep fully connected layer are extracted and used as features. Then, these features are feedforward to a single hidden layer neural network that is cross-validated using 10-folds to classify among four classes of breast density. The global accuracy of this method is 98.4%, presenting only 1.6% of misclassification. However, the small set of samples and memory constraints required the reuse of data in both CNN and MLP-NN, therefore overfitting might have influenced the results even though we cross-validated the network. Thus, although we presented a promising method for extracting features and classifying breast density, a greater database is

  5. Mammographic manifestations of mammary hamartoma (with an analysis of 10 cases)

    International Nuclear Information System (INIS)

    Yu Cheng; Luo Zebin; Chen Yun; Lin Wenmiao; Diao Shenglin

    2006-01-01

    Objective: To analyze the mammographic characteristics and the pathological basis of mammary hamartoma. Methods: The mammogram of 10 cases of mammary hamartoma proved by pathology were retrospectively analyzed. The patients aged from 25 to 56 years with an average age of (40.1 ± 5.4 years ). Results: According to the fat/parenchyma ratio, the mammgraphic manifestations of mammary hamartoma were divided into three types. 2 highly radiolucent lesions were classified as fat type, 2 lesions with high density were classified as dense type and the rest 6 lesions were the mixed type composed of adipose and glandular tissue. The mixed type was the most distinctive, while the dense or rat type was easy to be misdiagnosed. Accurate diagnosis was made in 6 cases out of, and the overall diagnostic accuracy was 60%. Conclusion: Mammography is the choice of diagnosis, and an accurate diagnosis will help surgical planning. (authors)

  6. Interaction of mammographic breast density with menopausal status and postmenopausal hormone use in relation to the risk of aggressive breast cancer subtypes.

    Science.gov (United States)

    Yaghjyan, Lusine; Tamimi, Rulla M; Bertrand, Kimberly A; Scott, Christopher G; Jensen, Matthew R; Pankratz, V Shane; Brandt, Kathy; Visscher, Daniel; Norman, Aaron; Couch, Fergus; Shepherd, John; Fan, Bo; Chen, Yunn-Yi; Ma, Lin; Beck, Andrew H; Cummings, Steven R; Kerlikowske, Karla; Vachon, Celine M

    2017-09-01

    We examined the associations of mammographic breast density with breast cancer risk by tumor aggressiveness and by menopausal status and current postmenopausal hormone therapy. This study included 2596 invasive breast cancer cases and 4059 controls selected from participants of four nested case-control studies within four established cohorts: the Mayo Mammography Health Study, the Nurses' Health Study, Nurses' Health Study II, and San Francisco Mammography Registry. Percent breast density (PD), absolute dense (DA), and non-dense areas (NDA) were assessed from digitized film-screen mammograms using a computer-assisted threshold technique and standardized across studies. We used polytomous logistic regression to quantify the associations of breast density with breast cancer risk by tumor aggressiveness (defined as presence of at least two of the following tumor characteristics: size ≥2 cm, grade 2/3, ER-negative status, or positive nodes), stratified by menopausal status and current hormone therapy. Overall, the positive association of PD and borderline inverse association of NDA with breast cancer risk was stronger in aggressive vs. non-aggressive tumors (≥51 vs. 11-25% OR 2.50, 95% CI 1.94-3.22 vs. OR 2.03, 95% CI 1.70-2.43, p-heterogeneity = 0.03; NDA 4th vs. 2nd quartile OR 0.54, 95% CI 0.41-0.70 vs. OR 0.71, 95% CI 0.59-0.85, p-heterogeneity = 0.07). However, there were no differences in the association of DA with breast cancer by aggressive status. In the stratified analysis, there was also evidence of a stronger association of PD and NDA with aggressive tumors among postmenopausal women and, in particular, current estrogen+progesterone users (≥51 vs. 11-25% OR 3.24, 95% CI 1.75-6.00 vs. OR 1.93, 95% CI 1.25-2.98, p-heterogeneity = 0.01; NDA 4th vs. 2nd quartile OR 0.43, 95% CI 0.21-0.85 vs. OR 0.56, 95% CI 0.35-0.89, p-heterogeneity = 0.01), even though the interaction was not significant. Our findings suggest that associations of mammographic

  7. Mammographic, pathologic, and treatment-related factors associated with local recurrence in patients with early-stage breast cancer treated with breast conserving therapy

    International Nuclear Information System (INIS)

    Kini, Vijay R.; Vicini, Frank A.; Frazier, Robert; Victor, Sandra J.; Wimbish, Kathryn; Martinez, Alvaro A.

    1999-01-01

    Background: We retrospectively reviewed our institution's experience treating early-stage breast cancer patients with breast conserving therapy (BCT) to determine clinical, pathologic, mammographic, and treatment-related factors associated with outcome. Methods: Between January 1980 and December 1987, 400 cases of Stage I and II breast cancer were managed with BCT at William Beaumont Hospital, Royal Oak, Michigan. All patients underwent at least an excisional biopsy. Radiation treatment consisted of delivering 45-50 Gy to the whole breast, followed by a boost to the tumor bed to at least 60 Gy in all patients. The median follow-up in the 292 surviving patients is 118 months. Multiple clinical, pathologic, mammographic, and treatment-related factors were analyzed for an association with local recurrence and survival. Results: A total of 37 local recurrences developed in the treated breast, for a 5- and 10-year actuarial rate of 4% and 10%, respectively. On univariate analysis, patient age ≤ 35 years (25% vs. 7%, p = 0.004), and positive surgical margins (17% vs. 6%, p = 0.018) were associated with an increased risk of local recurrence at 10 years. On multivariate analysis, only age ≤ 35 years remained significant. A subset analysis of 214 patients with evaluable mammographic findings was performed. On univariate analysis, age ≤ 35 years (38% vs. 8%, p = 0.0029) and the presence of calcifications on preoperative mammography (22% vs. 6%, p = 0.0016) were associated with an increased risk of local recurrence. On multivariate analysis, both of these factors remained significant. The presence of calcifications on preoperative mammography did not affect the rates of overall survival, disease-free survival, and cause-specific survival. Conclusion: In patients with early-stage breast cancer treated with BCT, age ≤ 35 years and calcifications on preoperative mammography appear to be associated with an increased risk of local recurrence

  8. Evaluation of the observation of breast glands condition in mammographic early detection programme

    International Nuclear Information System (INIS)

    Kleszczewska, J.; Zomer-Drozda, J.; Tarlowska, L.; Romejko, M.

    1993-01-01

    The results of mammography tests were evaluated for 542 female employees of higher schools during an observation continued over 1 to 7.5 years, and they were compared with the results of the first test. Among 22 cancers detected and confirmed by macroscopic examination, mammography result turned out to be false negative in 2 cases. A positive error occurred in 7 cases. Cancer developed during observation in 8 women, that is, in 4 women from the group of 365 who earlier had correct mammography results (1.1%) and another 4 in the group of 154 women originally showing benign changes in their breast glands (2.6%). This work confirms the importance of regular checkups in the mammographic early detection programme. (author)

  9. Deep learning in breast cancer risk assessment: evaluation of convolutional neural networks on a clinical dataset of full-field digital mammograms.

    Science.gov (United States)

    Li, Hui; Giger, Maryellen L; Huynh, Benjamin Q; Antropova, Natalia O

    2017-10-01

    To evaluate deep learning in the assessment of breast cancer risk in which convolutional neural networks (CNNs) with transfer learning are used to extract parenchymal characteristics directly from full-field digital mammographic (FFDM) images instead of using computerized radiographic texture analysis (RTA), 456 clinical FFDM cases were included: a "high-risk" BRCA1/2 gene-mutation carriers dataset (53 cases), a "high-risk" unilateral cancer patients dataset (75 cases), and a "low-risk dataset" (328 cases). Deep learning was compared to the use of features from RTA, as well as to a combination of both in the task of distinguishing between high- and low-risk subjects. Similar classification performances were obtained using CNN [area under the curve [Formula: see text]; standard error [Formula: see text

  10. [Conventional radiology, digital radiology with photostimulable phosphor, laser digitalization of thoracic radiographic films at the bedside. A comparative study].

    Science.gov (United States)

    Miceli, M; Stamati, R; Burci, P; Guidarelli, G; Sartoni Galloni, S

    1992-10-01

    The bedside chest images obtained with conventional radiology and with "on line" and "off line" digital modalities were compared to evaluate the respective capabilities in visualizing chest anatomical structures. Seventy patients were submitted to bedside chest examinations with a portable unit; both a conventional film and a digital system (PCR Graphics 1, Philips) with photostimulable phosphor imaging plate were fitted in the radiographic cassette. The former was digitized using an "off line" laser beam unit (FD 2000, Dupont); the latter was subsequently postprocessed by modifying contrast, optical density and spatial frequencies. Thus, 4 different viewing modalities were obtained for each examination: a) conventional radiography; b) standard digital radiography; c) postprocessed digital radiography; d) digitized conventional radiography. Detectability rates of chest anatomical structures were analyzed by 4 independent radiologists on the different images and expressed by a score 1-4. The values were always higher with digital modalities than with the conventional one and the differences were statistically significant (Student's t-test modified by Bonferroni). In particular, the greatest difference was found between c) and a) in retrocardiac lung parenchyma and in skeletal structures, in favour of c). Concerning the comparative adequacy of the various digital modalities, higher detectability rates of chest anatomical structures were obtained with c), but also with b), than with d).

  11. Comparison of mammographic and sonographic findings in typical and atypical medullary carcinomas of the breast

    International Nuclear Information System (INIS)

    Yilmaz, E.; Lebe, B.; Balci, P.; Sal, S.; Canda, T.

    2002-01-01

    AIM: The aim of this study was to describe the contribution of mammographic and sonographic findings to the discrimination of typical and atypical histopathologic groups of medullary carcinomas of the breast. MATERIALS AND METHODS: Imaging findings were retrospectively assessed in 33 women with medullary carcinomas (15 typical medullary carcinomas and 18 atypical medullary carcinomas) identified during pre-operative mammography. Twenty-nine of these women also had ultrasound and these findings were reviewed. RESULTS: Mammography showed a well circumscribed mass in 10 of the 15 (67%) typical medullary carcinomas and in four of the 17 (24%) atypical medullary carcinomas (P < 0.02). One small tumour in a woman with atypical medullary carcinoma was missed on mammography and was shown only on sonography. Sonographically, an irregular margin surrounding the whole mass or part of it was seen in three out of 14 (21%) patients with typical medullary carcinoma and in nine out of 15 (60%) patients with atypical medullary carcinomas (P < 0.05). Posterior acoustic shadowing was more often observed in the typical medullary carcinoma group than in atypical medullary carcinoma and the difference was found to be statistically significant (P < 0.05). None of the other mammographic and sonographic findings were sufficiently characteristic to allow for a differentiation between two groups. CONCLUSION: When typical medullary carcinomas were compared with atypical medullary carcinomas according to imaging features, they tended to be well circumscribed masses on both mammography and sonography, and a posterior acoustic shadow was not found on sonography. However, the imaging findings in these two subgroups often resembled each other and histopathology will always be required to confirm the diagnosis. Yilmaz, E. et al. (2002)

  12. Comparison of mammographic and sonographic findings in typical and atypical medullary carcinomas of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Yilmaz, E.; Lebe, B.; Balci, P.; Sal, S.; Canda, T

    2002-07-01

    AIM: The aim of this study was to describe the contribution of mammographic and sonographic findings to the discrimination of typical and atypical histopathologic groups of medullary carcinomas of the breast. MATERIALS AND METHODS: Imaging findings were retrospectively assessed in 33 women with medullary carcinomas (15 typical medullary carcinomas and 18 atypical medullary carcinomas) identified during pre-operative mammography. Twenty-nine of these women also had ultrasound and these findings were reviewed. RESULTS: Mammography showed a well circumscribed mass in 10 of the 15 (67%) typical medullary carcinomas and in four of the 17 (24%) atypical medullary carcinomas (P < 0.02). One small tumour in a woman with atypical medullary carcinoma was missed on mammography and was shown only on sonography. Sonographically, an irregular margin surrounding the whole mass or part of it was seen in three out of 14 (21%) patients with typical medullary carcinoma and in nine out of 15 (60%) patients with atypical medullary carcinomas (P < 0.05). Posterior acoustic shadowing was more often observed in the typical medullary carcinoma group than in atypical medullary carcinoma and the difference was found to be statistically significant (P < 0.05). None of the other mammographic and sonographic findings were sufficiently characteristic to allow for a differentiation between two groups. CONCLUSION: When typical medullary carcinomas were compared with atypical medullary carcinomas according to imaging features, they tended to be well circumscribed masses on both mammography and sonography, and a posterior acoustic shadow was not found on sonography. However, the imaging findings in these two subgroups often resembled each other and histopathology will always be required to confirm the diagnosis. Yilmaz, E. et al. (2002)

  13. Digital communication system

    Science.gov (United States)

    Monford, L. G., Jr. (Inventor)

    1974-01-01

    A digital communication system is reported for parallel operation of 16 or more transceiver units with the use of only four interconnecting wires. A remote synchronization circuit produces unit address control words sequentially in data frames of 16 words. Means are provided in each transceiver unit to decode calling signals and to transmit calling and data signals. The transceivers communicate with each other over one data line. The synchronization unit communicates the address control information to the transceiver units over an address line and further provides the timing information over a clock line. A reference voltage level or ground line completes the interconnecting four wire hookup.

  14. EnviroAtlas - NHDPlus V2 Hydrologic Unit Boundaries Web Service - Conterminous United States

    Data.gov (United States)

    U.S. Environmental Protection Agency — This EnviroAtlas web service contains layers depicting hydrologic unit boundary layers and labels for the Subregion level (4-digit HUCs), Subbasin level (8-digit...

  15. A biomechanical model of mammographic compressions.

    Science.gov (United States)

    Chung, J H; Rajagopal, V; Nielsen, P M F; Nash, M P

    2008-02-01

    A number of biomechanical models have been proposed to improve nonrigid registration techniques for multimodal breast image alignment. A deformable breast model may also be useful for overcoming difficulties in interpreting 2D X-ray projections (mammograms) of 3D volumes (breast tissues). If a deformable model could accurately predict the shape changes that breasts undergo during mammography, then the model could serve to localize suspicious masses (visible in mammograms) in the unloaded state, or in any other deformed state required for further investigations (such as biopsy or other medical imaging modalities). In this paper, we present a validation study that was conducted in order to develop a biomechanical model based on the well-established theory of continuum mechanics (finite elasticity theory with contact mechanics) and demonstrate its use for this application. Experimental studies using gel phantoms were conducted to test the accuracy in predicting mammographic-like deformations. The material properties of the gel phantom were estimated using a nonlinear optimization process, which minimized the errors between the experimental and the model-predicted surface data by adjusting the parameter associated with the neo-Hookean constitutive relation. Two compressions (the equivalent of cranio-caudal and medio-lateral mammograms) were performed on the phantom, and the corresponding deformations were recorded using a MRI scanner. Finite element simulations were performed to mimic the experiments using the estimated material properties with appropriate boundary conditions. The simulation results matched the experimental recordings of the deformed phantom, with a sub-millimeter root-mean-square error for each compression state. Having now validated our finite element model of breast compression, the next stage is to apply the model to clinical images.

  16. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Michell, M.J.; Iqbal, A.; Wasan, R.K.; Evans, D.R.; Peacock, C.; Lawinski, C.P.; Douiri, A.; Wilson, R.; Whelehan, P.

    2012-01-01

    Aim: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. Materials and methods: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. Results: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286 (37.68%) as benign, and 269 (35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBT combined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. Conclusion: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities.

  17. The diagnostic accuracy of dual-view digital mammography, single-view breast tomo-synthesis and a dual-view combination of breast tomo-synthesis and digital mammography in a free-response observer performance study

    International Nuclear Information System (INIS)

    Svahn, T.; Andersson, I.; Chakraborty, D.; Svensson, S.; Ikeda, D.; Foernvik, D.; Mattsson, S.; Tingberg, A.; Zackrisson, S.

    2010-01-01

    The purpose of the present study was to compare the diagnostic accuracy of dual-view digital mammography (DM), single view breast tomo-synthesis (BT) and BT combined with the opposite DM view. Patients with subtle lesions were selected to undergo BT examinations. Two radiologists who are non-participants in the study and have experience in using DM and BT determined the locations and extents of lesions in the images. Five expert mammographers interpreted the cases using the free-response paradigm. The task was to mark and rate clinically reportable findings suspicious for malignancy and clinically relevant benign findings. The marks were scored with reference to the outlined regions into lesion localization or non-lesion localization, and analysed by the jackknife alternative free-response receiver operating characteristic method. The analysis yielded statistically significant differences between the combined modality and dual-view DM (p < 0.05). No differences were found between single-view BT and dual-view DM or between single-view BT and the combined modality. (authors)

  18. Mammographic and ultrasound features of invasive lobular carcinoma of the breast

    International Nuclear Information System (INIS)

    Porter, Alan J.; Evans, Elizabeth B.; Foxcraft, Loani M.; Simpson, Peter T.; Lakhani, Sunil R.

    2014-01-01

    Invasive lobular cancer (ILC) is an important contributor to false negative mammography. This study aims to assess the value of digital mammography and to identify imaging features that could assist the radiologist to suggest the diagnosis of ILC prior to biopsy. Three hundred sixty-one cases of pure ILC diagnosed at the Wesley Breast Clinic during the period 1995–2010 were reviewed by one of the authors (AP). Radiological features were categorized, and clinical features and needle sampling results were recorded. Mammography was negative in 29.9% of ILCs. The commonest positive finding was a localized spiculated mass (41.8%). Thirty-four point nine per cent of lesions were visible in only one view, usually cranio-caudal. Calcification was not a feature of ILC. The use of digital mammography in 30% of cases did not decrease the false negative rate for ILC. Breast ultrasound (BUS) showed an abnormality in 97.8%, most commonly a localized irregular hypoechoic mass with shadowing. Digital mammography does not reduce false negative mammography in ILC. The poor visibility of ILCs may be partly related to their low density (mass/unit volume). ILCs may sometimes be poor attenuators of X-rays but excellent attenuators of ultrasound, causing marked acoustic shadowing. Bilateral whole BUS has a very low false negative rate in experienced hands and is mandatory in symptomatic women. The combination of poor visibility on mammography with high visibility on ultrasound, as well as certain characteristic ultrasound appearances of ILC, may enable the radiologist to suggest ILC as a diagnostic possibility, prior to biopsy.

  19. Trends in digital I and C for nuclear power plants

    International Nuclear Information System (INIS)

    Cook, B.M.

    2000-01-01

    Over the past decade, large-scale digital I and C systems have been installed on nuclear power plants as the original systems for plant operations. Examples of these include Sizewell B in the United Kingdom and Temelin NPP in the Czech Republic. Now, this digital technology is being used for replacement and upgrade systems such as those for Ringhals Unit 2 in Sweden and the Kewaunee plant in the United States. Such a digital upgrade is being planned for the Dukovany NPP in the Czech Republic. As the experience base grows with this digital technology on nuclear power plants, certain trends are developing in the application practices and licensing of these systems. This paper discusses these trends and suggests adaptations that may become necessary in the classical roles of vendors, regulators and plant operators. (author)

  20. Glycemic index, glycemic load and mammographic breast density: the EPIC Florence longitudinal study.

    Directory of Open Access Journals (Sweden)

    Giovanna Masala

    Full Text Available A few studies have evaluated the association between diet and mammographic breast density (MBD and results are inconsistent. MBD, a well-recognized risk factor for breast cancer, has been proposed as a marker of cumulative exposure to hormones and growth factors. Diets with a high glycemic index (GI or glycemic load (GL may increase breast cancer risk, via an effect on the insulin-like growth factor axis. We have investigated the association between carbohydrate intake, GI, GL and MBD in a prospective study. We identified a large series of women, in the frame of the EPIC-Florence cohort, with a mammogram taken five years after enrolment, when detailed information on dietary and lifestyle habits and anthropometric measurements had been collected. Mammograms have been retrieved (1,668, 83% and MBD assessed according to Wolfe's classification. We compared women with high MBD (P2+DY Wolfe's categories with those with low MBD (N1+P1 through logistic models adjusted for age, education, body mass index, menopause, number of children, breast feeding, physical activity, non-alcohol energy, fibers, saturated fat and alcohol. A direct association between GL and high MBD emerged in the highest quintile of intake in comparison with the lowest quintile (OR = 1.73, 95%CI 1.13-2.67, p for trend = 0.048 while no association with glycemic index was evident. These results were confirmed after exclusion of women reporting to be on a diet or affected with diabetes, and when Hormone Replacement Therapy at the date of mammographic examination used to assess MBD was considered. The effect was particularly evident among leaner women, although no interaction was found. A positive association was suggested for increasing simple sugar and total carbohydrates intakes limited to the highest quintiles. In this Italian population we observed an association between glycemic load, total and rapidly absorbed carbohydrates and high MBD. These novel results warrant further

  1. Image quality of mammography in Croatian nationwide screening program: Comparison between various types of facilities

    International Nuclear Information System (INIS)

    Brnić, Zoran; Blašković, Darko; Klasić, Branimir; Ramač, Jelena Popić; Flegarić-Bradić, Mirjana; Štimac, Damir; Lubina, Ivan Zvonimir; Brnić, Vedran; Faj, Dario

    2012-01-01

    Purpose: The study was aimed to provide objective evidence about the mammographic image quality in Croatia, to compare it between different types of MG facilities and to identify the most common deficiencies and possible reasons as well as the steps needed to improve image quality. Materials and methods: A total of 420 mammographic examinations collected from 84 mammographic units participating in the Croatian nationwide breast cancer screening program were reviewed in terms of four image quality categories: identification of patient and examination, breast positioning and compression, exposure and contrast, and artifacts. Those were rated using image evaluating system based on American College of Radiology and European Commission proposals. The results were compared among different types of mammographic units, and common image quality deficiencies were identified. Results: Total image quality scores of 12.8, 16.1, 13.0 and 13.7 were found for general hospitals, university hospitals, private clinics and public healthcare centres, respectively. Average score for all mammographic units was 13.5 (out of 25 points). University hospitals were significantly better than all other mammography units in overall image quality, which was mostly contributed by better breast positioning practices. Private clinics showed the worst results in identification, exposure, contrast and artifacts. Conclusions: Serious deficiencies in identification and breast positioning, which might compromise breast cancer screening outcome, were detected in our material. They occur mainly due to subjective reasons and could be corrected through additional staff training and improvement of working discipline.

  2. Attribute-Based Digital Signature System

    NARCIS (Netherlands)

    Ibraimi, L.; Asim, Muhammad; Petkovic, M.

    2011-01-01

    An attribute-based digital signature system comprises a signature generation unit (1) for signing a message (m) by generating a signature (s) based on a user secret key (SK) associated with a set of user attributes, wherein the signature generation unit (1) is arranged for combining the user secret

  3. Tribodynamic Modeling of Digital Fluid Power Motors

    DEFF Research Database (Denmark)

    Johansen, Per

    . In fluid power motoring and pumping units, a significant problem is that loss mechanisms do not scale down with diminishing power throughput. Although machines can reach peak efficiencies above 95%, the actual efficiency during operation, which includes part-load situations, is much lower. The invention...... of digital fluid power displacement units has been able to address this problem. The main idea of the digital fluid power displacement technology is to disable individual chambers, by use of electrical actuated valves. A displacement chamber is disabled by keeping the valve, between the chamber and the low...... design methods and tools are important to the development of digital fluid power machines. The work presented in this dissertation is part of a research program focusing on the development of digital fluid power MW-motors for use in hydraulic drive train in wind turbines. As part of this development...

  4. Mammographic breast density patterns in asymptomatic mexican women.

    Science.gov (United States)

    Calderón-Garcidueñas, Ana Laura; Sanabria-Mondragón, Mónica; Hernández-Beltrán, Lourdes; López-Amador, Noé; Cerda-Flores, Ricardo M

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (χ(2)) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns.

  5. Mammographic Breast Density Patterns in Asymptomatic Mexican Women

    International Nuclear Information System (INIS)

    Garciduenas, A.L.C.; Amador, N.; Mondragon, M.S.; Hernaan, L.; Cerda-Flores, R.M.

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (X 2 ) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns

  6. Mammographic Breast Density Patterns in Asymptomatic Mexican Women

    International Nuclear Information System (INIS)

    Calderón-Garcidueñas, Ana Laura; Sanabria-Mondragón, Mónica; Hernández-Beltrán, Lourdes; López-Amador, Noé; Cerda-Flores, Ricardo M.

    2012-01-01

    Breast density (BD) is a risk factor for breast cancer. Aims. To describe BD patterns in asymptomatic Mexican women and the pathological mammographic findings. Methods and Material. Prospective, descriptive, and comparative study. Women answered a questionnaire and their mammograms were analyzed according to BI-RADS. Univariate (χ 2 ) and conditional logistic regression analyses were performed. Results. In 300 women studied the BD patterns were fat 56.7% (170), fibroglandular 29% (87), heterogeneously dense 5.7% (17), and dense pattern 8.6% (26). Prevalence of fat pattern was significantly different in women under 50 years (37.6%, 44/117) and older than 50 (68.8%, 126/183). Patterns of high breast density (BD) (dense + heterogeneously dense) were observed in 25.6% (30/117) of women ≤50 years and 7.1% (13/183) of women >50. Asymmetry in BD was observed in 22% (66/300). Compression cone ruled out underlying disease in 56 cases. In the remaining 10, biopsy revealed one fibroadenoma, one complex cyst, and 6 invasive and 2 intraductal carcinomas. 2.6% (8/300) of patients had non-palpable carcinomas. Benign lesions were observed in 63.3% (190/300) of cases, vascular calcification in 150 cases (78.9%), and fat necrosis in 38 cases (20%). Conclusions. Mexican women have a low percentage of high-density patterns

  7. Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

    DEFF Research Database (Denmark)

    Diakos, Konstantinos; Wu, Qiuwei; Nielsen, Arne Hejde

    2014-01-01

    that is able to derive and communicate synchrophasor measurements of different parts of the power network and the development of tests, according to IEEE standards, that evaluate the performance of PMUs and PDCs. The tests are created by using a Real Time Digital Simulation (RTDS) system. The results obtained......The main focus of the electrical engineers nowadays, is to develop a smart grid that is able to monitor, evaluate and control the power system operation. The integration of Intelligent Electronic Devices (IED s) to the power network, is a strong indication of the inclination to lead the power...... network to a more reliable, secure and economic operation. The implementation of these devices though, demands the warranty of a secure operation and high-accuracy performance. This paper describes the procedure of establishing a PMU (Phasor Measurement Unit)–PDC (Phasor Data Concentrator) platform...

  8. EnviroAtlas - Big Game Hunting Recreation Demand by 12-Digit HUC in the Conterminous United States

    Science.gov (United States)

    This EnviroAtlas dataset includes the total number of recreational days per year demanded by people ages 18 and over for big game hunting by location in the contiguous United States. Big game includes deer, elk, bear, and wild turkey. These values are based on 2010 population distribution, 2011 U.S. Fish and Wildlife Service (FWS) Fish, Hunting, and Wildlife-Associated Recreation (FHWAR) survey data, and 2011 U.S. Department of Agriculture (USDA) Forest Service National Visitor Use Monitoring program data, and have been summarized by 12-digit hydrologic unit code (HUC). This dataset was produced by the US EPA to support research and online mapping activities related to the EnviroAtlas. EnviroAtlas (https://www.epa.gov/enviroatlas) allows the user to interact with a web-based, easy-to-use, mapping application to view and analyze multiple ecosystem services for the contiguous United States. The dataset is available as downloadable data (https://edg.epa.gov/data/Public/ORD/EnviroAtlas) or as an EnviroAtlas map service. Additional descriptive information about each attribute in this dataset can be found in its associated EnviroAtlas Fact Sheet (https://www.epa.gov/enviroatlas/enviroatlas-fact-sheets).

  9. Results of breast conserving therapy for early breast cancer and the role of mammographic follow-up

    International Nuclear Information System (INIS)

    Grosse, Antje; Schreer, Ingrid; Frischbier, Hans-Joachim; Maass, Heinrich; Loening, Thomas; Bahnsen, Jens

    1997-01-01

    Purpose: The following article is a review of 23 years of breast-conserving therapy in our hospital. This study was performed to assess and improve the follow-up care of women with early breast cancer and to evaluate whether or not biannual mammogram is useful. Methods and Materials: Between 1972 and December 1995, 3072 women with pathological size pT1 and pT2 breast cancer were treated with conservative surgery and radiation therapy. Eighty-five patients developed a recurrence in the treated breast as the first site of failure, 12 of which had positive axillary nodes. In the following patient study, those with an noninvasive recurrence were excluded. A retrospective assessment of the entire mammographic course was made, starting with the mammogram at the time of original diagnosis to the mammogram of the recurrence. Results: In our study group the probability for local failure ranged from 1 to 2% per year. At 5 and 10 years the actuarial rates were 5 and 10%. The median time to recurrence was 41 months (range 8-161). Twenty-six (31%) recurrences were detected by mammography alone, 10 (12%) by clinical examination only, and 35 (41%) by both methods. For the patients with an ipsilateral recurrence, the overall actuarial 5- and 10-year survival after treatment was 87 and 70%, respectively. The 5-year actuarial rate of survival from salvage mastectomy was 61%. Conclusion: Considering the high percentage of recurrences detectable by mammography and the possibility of detection within a short-term interval, we think biannual mammographic follow-up is appropriate for the first years following breast-conserving therapy

  10. THE HIGH-PERFORMANCE RESOURCE-SPARING TECHNOLOGIES IN THE DIAGNOSTIC MAMMOLOGY (On the fifth anniversary of the Russian association of mammologists

    Directory of Open Access Journals (Sweden)

    N. I. Rozhkova

    2008-01-01

    Full Text Available There have been presented the main achievements in the field of mammologic service development in Russia owing to creation and introduction of the domestic mammographic stationary digital and mobile mammographs, organization of the system of the continuous education of the specialists on basis of interdisciplinary integration, as well as introduction of the novel technologies of the radiologi- cal examination, interventional radiology, molecular biology, informational technologies, realization of the wide-ranging information- al educational work. The diagnostic mammology development perspectives are outlined.

  11. Circumscribed breast carcinoma: Mammographic and sonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Lee, Yul; Park, Ki Soon; Lee, Ke Sook [College of Medicine, Hallym University, Seoul (Korea, Republic of)

    1992-03-15

    Circumscribe breast cancer is a well demarcated mass with or without a lobulated border simulating a benign tumor like fibroadenoma on mammography or breast US and is reported as approximate 10% of the incidence among primary breast carcinoma(1.2). Pathologically medullary, colloid, papillary, intraductal and rarely invasive ductal carcinomas are included in this group which show the less intense desmoplastic reaction than the scirrhous type cancer, resulting in the most favorable prognosis of all carcinoma of the breast. Among 214 primary breast carcinoma during the past 8 years, we experienced 6 case of pathologically proven circumscribed breast cancer(2 cases of medullary carcinoma, 1 of colloid carcinoma, 1 of intracystic papillary carcinoma, 2 of comedo type intraductal carcinoma). Clinically 2 cases showed bloody nipple discharge from one hole of a unilateral nipple orifice. Mammography showed a well circumscribed nodule with or without partial lobular contour and no pathologic calcification. Breast sonographic findings were a well defined heterogeneous hypoechoic nodule with weak posterior acoustic enhancement. Characteristically a thin dilated lactiferous duct between the mass and the nipple on US could be detected in 2 cases which clinically was accompanied by bloody nipple discharge. Although the mammographic criteria is promising as benign tumor, the possibility of circumscribed as benign tumor, the possibility of circumscribed breast carcinoma must be considered in heterogeneous hypoechoic nodule with weak posterior acoustic enhancement in US, especially in the presence of a dilated lactiferous duct between the mass and the nipple with bloody nipple discharge.

  12. Selective magnetic resonance imaging (MRI) in invasive lobular breast cancer based on mammographic density: does it lead to an appropriate change in surgical treatment?

    Science.gov (United States)

    Bansal, Gaurav J; Santosh, Divya; Davies, Eleri L

    2016-01-01

    The purpose of this study was to evaluate whether high mammographic density can be used as one of the selection criteria for MRI in invasive lobular breast cancer (ILC). In our institute, high breast density has been used as one of the indications for performing MRI scan in patients with ILC. We divided the patients in two groups, one with MRI performed pre-operatively and other without MRI. We compared their surgical procedures and analyzed whether surgical plan was altered after MRI. In case of alteration of plan, we analyzed whether the change was adequate by comparing post-operative histological findings. Between 2011 and 2015, there were a total of 1601 breast cancers with 97 lobular cancers, out of which 36 had pre-operative MRI and 61 had no MRI scan. 12 (33.3%) had mastectomy following MRI, out of which 9 (25%) had change in surgical plan from conservation to mastectomy following MRI. There were no unnecessary mastectomies in the MRI group. However, utilization of MRI in this cohort of patients did not reduce reoperation rate (19.3%). Lobular carcinoma in situ (LCIS) was identified in 60% of reoperations on post-surgical histology. Patients in the "No MRI" group had higher mastectomy rate 26 (42.6%), which was again appropriate. High mammographic density is a useful risk stratification criterion for selective MRI in ILC within a multidisciplinary team meeting setting. Provided additional lesions identified on MRI are confirmed with biopsy, pre-operative MRI does not cause unnecessary mastectomies. Used in this selective manner, reoperation rates were not eliminated, albeit reduced when compared to literature. High mammographic breast density can be used as one of the selection criteria for pre-operative MRI in ILC without an increase in inappropriate mastectomies with potential time and cost savings. In this cohort, re-excisions were not reduced markedly with pre-operative MRI.

  13. Steerable dyadic wavelet transform and interval wavelets for enhancement of digital mammography

    Science.gov (United States)

    Laine, Andrew F.; Koren, Iztok; Yang, Wuhai; Taylor, Fred J.

    1995-04-01

    This paper describes two approaches for accomplishing interactive feature analysis by overcomplete multiresolution representations. We show quantitatively that transform coefficients, modified by an adaptive non-linear operator, can make more obvious unseen or barely seen features of mammography without requiring additional radiation. Our results are compared with traditional image enhancement techniques by measuring the local contrast of known mammographic features. We design a filter bank representing a steerable dyadic wavelet transform that can be used for multiresolution analysis along arbitrary orientations. Digital mammograms are enhanced by orientation analysis performed by a steerable dyadic wavelet transform. Arbitrary regions of interest (ROI) are enhanced by Deslauriers-Dubuc interpolation representations on an interval. We demonstrate that our methods can provide radiologists with an interactive capability to support localized processing of selected (suspicion) areas (lesions). Features extracted from multiscale representations can provide an adaptive mechanism for accomplishing local contrast enhancement. By improving the visualization of breast pathology can improve changes of early detection while requiring less time to evaluate mammograms for most patients.

  14. Mammographically detected breast arterial calcifications: Indicators for arteriosclerotic diseases?

    International Nuclear Information System (INIS)

    Taskin, Fuesun; Akdilli, Alev; Karaman, Can; Unsal, Alparslan; Koeseoglu, Kutsi; Ergin, Filiz

    2006-01-01

    Purpose: To determine the prevalence of breast arterial calcifications (BAC) detected on mammography and search for conditions that may influence their existence. Materials and methods: The mammograms of 6156 consecutive patients were reevaluated for the presence of BAC. Four hundred eighty-five women having BAC were enrolled in the patient group. Additionally, randomly selected 500 women, without BAC constituted the control group. Hospital records of the participants were reviewed for parity, menopausal status, oral contraceptive agent (OCA) usage, hormone replacement therapy (HRT) usage, presence of diabetes, hypertension, hyperlipidemia, albuminuria and history of myocardial infarction (MI). Results: Prevalence of BAC was 7.9% on mammograms. Ninety-four women were aged between 40 and 49 years, 165 were aged between 50 and 59 years and 226 were over 60 years among BAC positive 485 women. A significant relationship was found for the frequency of BAC versus age and HRT usage in all age groups (p 0.05). Conclusion: Most benign findings like BAC are not routinely reported during mammographic evaluation. Our study showed that, presence of BAC on mammography was strongly related to advancing age. However, these findings may signify a systemic risk and can be used as precautious indicators for undocumented systemic diseases, especially in premenopausal women

  15. Are Qualitative Assessments of Background Parenchymal Enhancement, Amount of Fibroglandular Tissue on MR Images, and Mammographic Density Associated with Breast Cancer Risk?

    Science.gov (United States)

    Dontchos, Brian N.; Partridge, Savannah C.; Korde, Larissa A.; Lam, Diana L.; Scheel, John R.; Peacock, Sue; Lehman, Constance D.

    2015-01-01

    Purpose To investigate whether qualitative magnetic resonance (MR) imaging assessments of background parenchymal enhancement (BPE), amount of fibroglandular tissue (FGT), and mammographic density are associated with risk of developing breast cancer in women who are at high risk. Materials and Methods In this institutional review board–approved HIPAA-compliant retrospective study, all screening breast MR images obtained from January 2006 to December 2011 in women aged 18 years or older and at high risk for but without a history of breast cancer were identified. Women in whom breast cancer was diagnosed after index MR imaging comprised the cancer cohort, and one-to-one matching (age and BRCA status) of each woman with breast cancer to a control subject was performed by using MR images obtained in women who did not develop breast cancer with follow-up time maximized. Amount of BPE, BPE pattern (peripheral vs central), amount of FGT at MR imaging, and mammographic density were assessed on index images. Imaging features were compared between cancer and control cohorts by using conditional logistic regression. Results Twenty-three women at high risk (mean age, 47 years ± 10 [standard deviation]; six women had BRCA mutations) with no history of breast cancer underwent screening breast MR imaging; in these women, a diagnosis of breast cancer (invasive, n = 12; in situ, n = 11) was made during the follow-up interval. Women with mild, moderate, or marked BPE were nine times more likely to receive a diagnosis of breast cancer during the follow-up interval than were those with minimal BPE (P = .007; odds ratio = 9.0; 95% confidence interval: 1.1, 71.0). BPE pattern, MR imaging amount of FGT, and mammographic density were not significantly different between the cohorts (P = .5, P = .5, and P = .4, respectively). Conclusion Greater BPE was associated with a higher probability of developing breast cancer in women at high risk for cancer and warrants further study. © RSNA

  16. Evaluation of mammographic surveillance services in women aged 40-49 years with a moderate family history of breast cancer: a single-arm cohort study.

    Science.gov (United States)

    Duffy, S W; Mackay, J; Thomas, S; Anderson, E; Chen, T H H; Ellis, I; Evans, G; Fielder, H; Fox, R; Gui, G; Macmillan, D; Moss, S; Rogers, C; Sibbering, M; Wallis, M; Warren, R; Watson, E; Whynes, D; Allgood, P; Caunt, J

    2013-03-01

    Women with a significant family history of breast cancer are often offered more intensive and earlier surveillance than is offered to the general population in the National Breast Screening Programme. Up to now, this strategy has not been fully evaluated. To evaluate the benefit of mammographic surveillance for women aged 40-49 years at moderate risk of breast cancer due to family history. The study is referred to as FH01. This was a single-arm cohort study with recruitment taking place between January 2003 and February 2007. Recruits were women aged women were offered annual mammography for at least 5 years and observed for the occurrence of breast cancer during the surveillance period. The age group 40-44 years was targeted so that they would still be aged women, 94% of whom were aged women aged 40-49 years with a significant family history of breast or ovarian cancer is both clinically effective in reducing breast cancer mortality and cost-effective. There is a need to further standardise familial risk assessment, to research the impact of digital mammography and to clarify the role of breast density in this population. National Research Register N0484114809. This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 17, No. 11. See the HTA programme website for further project information.

  17. Vitamin D intake, month the mammogram was taken and mammographic density in Norwegian women aged 50-69.

    Directory of Open Access Journals (Sweden)

    Merete Ellingjord-Dale

    Full Text Available The role of vitamin D in breast cancer etiology is unclear. There is some, but inconsistent, evidence that vitamin D is associated with both breast cancer risk and mammographic density (MD. We evaluated the associations of MD with month the mammogram was taken, and with vitamin D intake, in a population of women from Norway--a country with limited sunlight exposure for a large part of the year.3114 women aged 50-69, who participated in the Norwegian Breast Cancer Screening Program (NBCSP in 2004 or 2006/07, completed risk factor and food frequency (FFQ questionnaires. Dietary and total (dietary plus supplements vitamin D, calcium and energy intakes were estimated by the FFQ. Month when the mammogram was taken was recorded on the mammogram. Percent MD was assessed using a computer assisted method (Madena, University of Southern California after digitization of the films. Linear regression models were used to investigate percent MD associations with month the mammogram was taken, and vitamin D and calcium intakes, adjusting for age, body mass index (BMI, study year, estrogen and progestin therapy (EPT, education, parity, calcium intakes and energy intakes.There was no statistical significant association between the month the mammogram was taken and percent MD. Overall, there was no association between percent MD and quartiles of total or dietary vitamin D intakes, or of calcium intake. However, analysis restricted to women aged <55 years revealed a suggestive inverse association between total vitamin D intake and percent MD (p for trend = 0.03.Overall, we found no strong evidence that month the mammogram was taken was associated with percent MD. We found no inverse association between vitamin D intake and percent MD overall, but observed a suggestive inverse association between dietary vitamin D and MD for women less than 55 years old.

  18. Dissimilarity Application in Digitized Mammographic Images Classification

    Directory of Open Access Journals (Sweden)

    Ubaldo Bottigli

    2006-06-01

    Full Text Available Purpose of this work is the development of an automatic classification system which could be useful for radiologists in the investigation of breast cancer. The software has been designed in the framework of the MAGIC-5 collaboration. In the traditional way of learning from examples of objects the classifiers are built in a feature space. However, an alternative ways can be found by constructing decision rules on dissimilarity (distance representations. In such a recognition process a new object is described by its distances to (a subset of the training samples. The use of the dissimilarities is especially of interest when features are difficult to obtain or when they have a little discriminative power. In the automatic classification system the suspicious regions with high probability to include a lesion are extracted from the image as regions of interest (ROIs. Each ROI is characterized by some features extracted from co-occurrence matrix containing spatial statistics information on ROI pixel grey tones. A dissimilarity representation of these features is made before the classification. A feed-forward neural network is employed to distinguish pathological records, from non-pathological ones by the new features. The results obtained in terms of sensitivity and specificity will be presented.

  19. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    Science.gov (United States)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  20. A study of mammographic and thermographic findings in breast diseases

    International Nuclear Information System (INIS)

    Cho, Won Sik; Jeon, Woo Ki; Kim, Jeong Sook; Han, Chang Yul

    1989-01-01

    The ideal diagnostic methods in breast diseases consist of the physical examination and complementary radiologic examination. In radiologic examination mammography is the most popular screening methods and the older simple complementary method is thermography which is efficient under the conditions of elevated skin temperature in inflammatory and malignant lesions. From Jan. 1st 1987 through Jan. 30th, 1988, 110 pts. with complaints of mammary problems were examined by mammography and thermography at Paik Hospital, Inje University. The authors selected and analyzed 97 cases had been pathologically proved through the operation and the fine needle aspiration biopsy. The results were as follows: 1. The most prevalent age group was 5th decade (40%) in cancer, 4th decade (47%) in mammary dysplasia and followed by fibroadenoma (63%) in 4th decade. 2. The mammographic and thermographic findings were compared between the mammary dysplasia and the infiltrating ductal cancer. In mammary dysplasia abnormal hot emissions were appeared in 9/44 (17%) correlated with atypical hyperchromatic cytoplasm relates to pre-malignant group. 3. We hope and expect the early detection of breast cancer through the follow-up study in pre-malignant group of mammary dysplasia