WorldWideScience
1

The interpolation damage detection method for frames under seismic excitation  

Science.gov (United States)

In this paper a new procedure, addressed as Interpolation Damage Detecting Method (IDDM), is investigated as a possible mean for early detection and location of light damage in a structure struck by an earthquake. Damage is defined in terms of the accuracy of a spline function in interpolating the operational mode shapes (ODS) of the structure. At a certain location a decrease (statistically meaningful) of accuracy, with respect to a reference configuration, points out a localized variation of the operational shapes thus revealing the existence of damage. In this paper, the proposed method is applied to a numerical model of a multistory frame, simulating a damaged condition through a reduction of the story stiffness. Several damage scenarios have been considered and the results ...

2011-10-01

2

Nano photonic sensors for microdamage detection : an exploratory simulation.  

Energy Technology Data Exchange (ETDEWEB)

Nano photonic materials are synthetically manufactured crystals at the nano scale with the target of creating a microstructure with a special electro-magnetic periodicity. Such nano photonic materials have the ability to control light propagation and thus are capable of creating photonic bandgaps in the frequency domain. We propose using nano photonic crystals as sensors to detect microdamage in composite materials. We demonstrate using a simulation model that a nano photonic sensor attached to a composite bar experiences a significant change in its bandgap profile when damage is induced in the composite bar. The model predicts the frequency response of the nano photonic sensor using the transfer matrix method. A damage metric to evaluate the change in the frequency response is developed. Successful developments of nano photonic sensors allow damage identification at scales not ...

2005-04-01

3

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex B - Sensors and non-destructive testing methods for damage detection in wind turbine blades  

Energy Technology Data Exchange (ETDEWEB)

This annex provides a description of the sensor schemes and the non-destructive testing (NDT) methods that have been investigated in this project. Acoustic emission and fibre optic sensors are described in some detail whereas only the key features of well-established NDT methods are presented. Estimates of the cost of different sensor systems are given and the advantages and disadvantages of the different schemes is discussed. (au)

2002-05-01

4

Gear crack level identification based on weighted K nearest neighbor classification algorithm  

British Library Electronic Table of Contents (United Kingdom)

A crack fault is one of the damage modes most frequently occurring in gears. Identifying different crack levels, especially for early cracks is a challenge in gear fault diagnosis. This paper aims to propose a method to classify the different levels of gear cracks automatically and reliably. In this method, feature parameters in time domain, specially designed for gear damage detection and in frequency domain are extracted to characterize the gear conditions. A two-stage feature selection and weighting technique (TFSWT) via Euclidean distance evaluation technique (EDET) is presented and adopted to select sensitive features and remove fault-unrelated features. A weighted K nearest neighbor (WKNN) classification algorithm is utilized to identify the gear crack levels. The gear crack experime...

2009-01-01

6

Fatigue crack detection in aircraft skin structures using eddy current array technique  

International Nuclear Information System (INIS)

Detection of fatigue damage cracks in aircraft skin structures is an ongoing NDT challenge. Cracks growing rate is difficult to predict, and for this reason, it is important to detect them as soon as possible to avoid a catastrophic break. Eddy current methods are known and well-accepted techniques which are relatively simple to carry out. However, with conventional inspection of airframe structures using standard driver-pickup eddy current probes, it is difficult to detect small fatigue cracks initiated in the second layer of the skin and in the shadow region at fastener holes. Such difficulty is related to fasteners length and their spacing which reduces test sensitivity. This report explains the development of improved eddy current probe/technique to detect and visualize fatigue cracks in fasteners. In this study, an eddy current array probe was evaluated and ...

2004-01-01

7

Safety assessment and life time management of nuclear power plants: from reasonable design to reliable structural health monitoring  

International Nuclear Information System (INIS)

Nowadays the safety of Nuclear Power Plants is becoming more and more significant. Therefore consideration of severe accidents shall be included in both design and operating process of Nuclear Power Plants. In particular ground motion forms one of the important natural hazards. For structural analysis both linear-elastic and non-linear methods are specified by the engineering codes for earthquake resistance design. However, time history analysis is required for investigation of non-linear structural behaviour. Moreover, non-linearities are often caused by the presence of damage. This can be detected by means of structural health monitoring and subsequently system identification. In this paper the advantages of both dynamic time history analysis and damage detection by means of wavelet analysis are discussed. First, the non-linear behaviour of a frame structure due to an artificial ...

2005-06-15

8

DMSA scan nomograms for renal length and area: Related to patient age and to body weight, height or surface area  

International Nuclear Information System (INIS)

Aim: To create nomograms for renal size as measured from DMSA renal studies, and to test the nomograms for their ability to separate normal from abnormal kidneys. Method: Renal length was measured from posterior oblique views and renal area from posterior views. Results from 253 patients with bilateral normal kidneys were used to create nomograms for renal size relative to patient age, body height, weight or body surface area (BSA). The nomograms enclosed 95% of the normal kidneys, thus indicating the range for 95% confidence limits, and hence the specificity. Each nomogram was then tested against 46 hypertrophied kidneys and 46 damaged kidneys. Results: The results from nomograms of renal length and renal area, compared to age, body height, body weight and BSA are presented. For each nomogram, the range is presented as a fraction of the mean value, and the number of abnormal kidneys (hypertrophied or damaged) outside the ...

2002-09-01

9

Fundamental study on leak detection of underground gas pipeline using passive acoustic method; Judogata onkyo keisoku ni yoru maisetsu gas dokan hason kasho no kenshutsu ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole diameter, spectra having the ...

1997-05-27

10

Imaging techniques for the injured ankle joint and tarsal bones  

International Nuclear Information System (INIS)

In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. ...

12

Gear crack level identification based on weighted K nearest neighbor classification algorithm  

Science.gov (United States)

A crack fault is one of the damage modes most frequently occurring in gears. Identifying different crack levels, especially for early cracks is a challenge in gear fault diagnosis. This paper aims to propose a method to classify the different levels of gear cracks automatically and reliably. In this method, feature parameters in time domain, specially designed for gear damage detection and in frequency domain are extracted to characterize the gear conditions. A two-stage feature selection and weighting technique (TFSWT) via Euclidean distance evaluation technique (EDET) is presented and adopted to select sensitive features and remove fault-unrelated features. A weighted K nearest neighbor (WKNN) classification algorithm is utilized to identify the gear crack levels. The gear crack experiments were conducted and the vibration signals were captured from the gears under different loads ...

2009-07-01

13

Recommendations for the prevention of damage to steam turbines. 2. rev. ed.  

International Nuclear Information System (INIS)

The purpose of the recommendation is to prevent, to detect, and to remove soiling of guide and retrating blades of steam turbines, e.g. on account of foreign matter in steam dissolved. (TK/LN).

14

Early failure detection of damages of roller bearing in frequency variable wind power gears. Internal analysis methods in CM systems; Fehlerfrueherkennung von Waelzlagerschaeden in drehzahlvariablen Windgetrieben. Interne Analysemethoden in CM-Systemen  

Energy Technology Data Exchange (ETDEWEB)

In the past, Condition Monitoring Systems (CMS) still showed weaknesses during the employment in the damage diagnosis and/or early failure detection of damages of roller bearings in transmissions of wind power plants. This is not only due to the insufficient consideration of the variable frequency of the wind power plants during the internal processing. The presently used methods of analysis result from the communication technology and are used successfully for years at frequency solid systems. Usually, only too few information are at the disposal to the supplier of CMS in order to parametrize their systems on the respective application particularly. An exact knowledge of the internal structure of the object to be diagnosed is compellingly necessary for a successful diagnosis so that a loadable statement based on the acquired measuring data base becomes possible. Furthermore, one must clarify the ...

2010-07-01

15

Damage characteristics of time domain histories  

Energy Technology Data Exchange (ETDEWEB)

It is possible to create nomographs similar to Fig. 2.10 to characterise damage potential of candidate time histories, provided there exists extensive records of earlier time-histories and the damage that they have caused. Thus in order to create such nomographs, one needs the correlated documentation between the input to the structure and the resulting damage. In order to use the Response-Spectra approach, one needs good statistical description of the input to the system. Extensive literature exists on both these methods. The MAC method that has being developed for the present research has yet to be validated. However, if it is successful, it would provide a valuable link between the SEA method and the rational method.

1989-11-01

16

Probabilistic leak before break evaluation of straight pipes of primary heat transport piping of Tarapur-3 and 4 NPP  

International Nuclear Information System (INIS)

Piping systems transporting high-pressure fluid will release a large amount of energy, leading to whipping of the broken pipe as well as impingement of the ejecting fluids on adjacent structures if they fracture unstably. Postulation of such an event in design of piping systems in nuclear power plants often requires various counter measures such as installation of pipe whip restraints or jet impingement shields to prevent such damage. One of the approaches to justify exclusion of unstable fracture from the design conditions is leak-before-break (LBB) analysis. In order to demonstrate LBB behavior, it is necessary to prove that in the presence of a part-through wall flaw in the pipe, this flaw will not grow through the wall under fatigue loading and is stable (level 2 LBB) and that the leak of fluid through the penetration is detected by leak detection systems before unstable fracture occurs (level 3 LBB). If this can be ...

2006-11-01

17

Whey protein isolate attenuates strength decline after eccentrically-induced muscle damage in healthy individuals  

UK PubMed Central (United Kingdom)

BackgroundWe examined the effects of short-term consumption of whey protein isolate on muscle proteins and force recovery after eccentrically-induced muscle damage in healthy individuals.MethodsSeventeen...Full Text Available

18

Multimodal MRI assessment of damage and plasticity caused by status epilepticus in the rat brain  

British Library Electronic Table of Contents (United Kingdom)

Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weighted imaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.

2011-01-01

19

Advanced experimental design applied to damage tolerance of composite materials  

Science.gov (United States)

This paper focuses on a factorial-based design strategy. The approach provides an efficient and statistically reliable means for assessing the influence of multivariable effects. It is applied to the detection and evaluation of damage in impacted composite sandwich panels. The experimental results obtained from this test strategy are utilized to form an empirical response function. The resulting polynomial relates damage area to residual compression strength at values of independent variables for which testing did not occur. The response function also identifies nonlinear interaction effects of key variabes that cannot be easily ascertained by traditional single-variable test strategies. Independent variables evaluated include core thickness, number of face sheet plys and impact energy. The methodology presented allows the designer to predict with more confidence the damage tolerance of a composite ...

1991-01-01

20

Development of SDT sensor based eddy current probe for detection of deep fatigue cracks in multi-layer structure  

British Library Electronic Table of Contents (United Kingdom)

The detection and characterization of deeply buried fatigue damage in thick, multi-layer airframe components pose significant technical challenges to the aviation safety community. Currently, no nondestructive evaluation technique is available to reliably detect such potential damage from the exterior of the airframe, which is highly desirable in light of inspection cost as well as avoidance of structure damage. Recent technological advances in high-sensitivity magnetic sensors, i.e., spin-dependent tunneling (SDT) sensors, make it feasible to employ electromagnetic inspection techniques for deep fatigue crack inspection. In this work, we report on the development and fabrication of a low frequency eddy current probe based on a magnetically shielded SDT pickup sensor concentrically located...

2010-01-01

21

Depth profile analysis on the nanometer scale by a combination of electron probe microanalysis (EPMA) and focused ion beam specimen preparation (FIB)  

International Nuclear Information System (INIS)

Electron probe microanalysis (EPMA) offers high sensitivity and high accuracy in quantitative measurements of chemical compositions and mass coverages. Owing to the low detection limits of the wavelength-dispersive technique, monolayers with mass coverages of about 0.05 pg cm z can be detected. Assuming a density of 5 g cm--3 this corresponds to a thickness of 0.1 nm. With these advantages in mind, EPMA was extended to depth profile analysis in the sub-micron range using a surface removal technique. The present paper shows how depth profile analysis can be improved by combining EPMA and the focused ion beam (FIB) technique. The focused ion beam system uses a Ga+ ion beam. The ion beam allows the milling of defined geometries on the nanometer scale, so that very shallow bevels with exactly defined angles in relation to the surface can be obtained. Low surface damage is expected due to low sputtering effects. Calibrated WDX ...

22

Mechanism of the accumulation effect in laser damage to polymers: appearance of microdamage due to an ionization absorption wave  

Energy Technology Data Exchange (ETDEWEB)

An investigation was made of the accumulation of laser damage to transparent polymers irradiated with nanosecond pulses from neodymium and ruby lasers. The damage was investigated by the method of scattering and luminescence in the visible and near ultraviolet parts of the spectrum. It was established that there were two stages in laser damage by repeated irradiation with pulses of intensity below the single-shot damage threshold. An absorbing defect evolved during the first stage in such a way as to create a thermal instability in the surrounding matrix. During the second stage this thermal instability caused spatial growth of laser damage because of propagation of an ionization-inducing absorption wave with a front traveling at the rate governed by the electron component of the thermal conductivity.

1984-04-01

23

Automated analysis of damages for radiation in plastics surfaces; Analisis automatizado de danos por radiacion en superficies plasticas  

Energy Technology Data Exchange (ETDEWEB)

Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)

1990-02-15

24

Simultaneous Reactivation of Ultraviolet Damage in Xanthium Leaves 1  

UK PubMed Central (United Kingdom)

Experiments on Xanthium leaf discs were carried out to determine whether concomitant photoreactivation could be detected and if so, to compare its effects with photoreactivation due...Full Text Available

1969-12-01

25

Generation and control of sound bullets with a nonlinear acoustic lens  

UK PubMed Central (United Kingdom)

Acoustic lenses are employed in a variety of applications, from biomedical imaging and surgery to defense systems and damage detection in materials. Focused acoustic signals, for example, enable ultrasonic...Full Text Available

2010-04-20

26

An immunochemical approach to the study of DNA damage and repair  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project is to produce antibodies to unique modified DNA bases and develop immunochemical assays to quantitate these lesions in damaged DNA. During this past year we have developed an antibody and chemical test to quantitate a basic sites in DNA and produced antibodies to the 8-oxopurines. This report discusses the detection of a basic sites in DNA and the preparation of antibodies to 8-hydroxyadenine and 8-hydroxyguanine.

1990-11-14

27

Fundamentals for remote structural health monitoring of wind turbine blades - a pre-project. Annex D - Full-scale test of wind turbine blade, using sensors and NDT  

Energy Technology Data Exchange (ETDEWEB)

A 19.1 metre wind turbine blade was subjected to static tests. The purpose of the test series was to verify the abilities of different types of sensors to detect damage in wind turbine blades. Prior to each of the static test-series an artificial damage was made on the blade. The damage made for each test-series was surveyed during each series by acoustic emission, fiber optic micro bend displacement transducers and strain gauges. The propagation of the damage was determined by use of ultra sonic and X-ray surveillance during stops in the test series. By use of acoustic emission it was possible to measure damage propagation before the propagation was of visible size. By use of fiber optic micro bend displacement transducers and strain gauges it was possible to measure minor damage propagation. By use of both ultra sonic, and X-ray ...

2002-05-01

28

Study of modal parameters and vibration signatures of notched concrete prisms  

International Nuclear Information System (INIS)

In the present study, vibration tests have been carried out on notched concrete prisms. The tests have been conducted to study modal parameters and vibration signatures in order to enhance the knowledge of monitoring concrete structures. Notch (artificially introduced crack) of constant widths and varying depths has been introduced in the concrete prisms at different locations. The specimens have been subjected to impact excitations by dropping a specific weight from a fixed height and at a particular location. The natural frequencies of notched and intact prisms have been experimentally measured. The frequency response functions (FRF) as obtained from multichannel pulse analyzer have been synthesized to evaluate the fundamental mode shape of vibration of the prisms by a curve fitting method. These curves have been further post-processed to obtain the modal curvature values. Pattern Recognition Scheme is applied to synthesize vibration signatures for the evaluation ...

2006-03-01

29

A spatial damage energy distribution calculation for ion-implanted materials  

International Nuclear Information System (INIS)

A simple method allowing easy calculation of the spatial damage energy distributions for ion-implanted materials is presented. The direct procedure takes account of the variation with depth of the lateral spreading of implanted ions, as well as the effects of energy transport by the recoiling target atoms. The subsequent computer program LUPIN-3D provides three-dimensional damage distributions and allows the construction of damage energy mappings. Various substrates of technological interest are investigated and several fields of application of the calculation are envisaged. The density of cascades can therefore be determined and heterogeneous amorphization models can be implemented. (orig.).

1989-01-01

30

Detection of pollution-induced forest decline in the Kola Peninsula using remote sensing and mathematical modelling  

Energy Technology Data Exchange (ETDEWEB)

Forests on the Kola Peninsula in Northern Russia grow close to the northern tree line. They are subjected to both natural and anthropogenic stress factors. The Cu-Ni smelter 'Severonikel' (Lat. 67 deg 55'N; Long. 32 deg 57'E) near Monchegorsk is one of the two major sources of sulphur dioxide and heavy metals emissions on the Kola Peninsula. These emissions have caused significant deterioration of the surrounding vegetation. The thesis demonstrates how methods of Remote sensing, ground survey and mathematical modelling can be integrated for monitoring of the smelter's environmental impact on the surrounding vegetation: ground truth data are used for calibration of remote-sensed data, which further serve to verify mathematical models. The study aims were: * to estimate the scale of airborne sulphur pollution from the smelting industry on the Kola Peninsula and its effect on vegetation; * to assess spatial extent of the ...

1998-07-01

31

Advanced phosphors  

Energy Technology Data Exchange (ETDEWEB)

This invention relates to new phosphor materials and to combinatorial methods of synthesizing and detecting the same. In addition, methods of using phosphors to generate luminescence are also disclosed.

2000-01-01

34

Enhanced defect detection and sizing accuracy using matrix phased array ultrasonic tools  

Energy Technology Data Exchange (ETDEWEB)

Although ultrasonic testing inspection technology and tools have improved significantly, there is still a need for more reliable detection, monitoring, and accurate sizing of crack-like and planar defects, complex corrosion damage, and detection of secondary features within deformed pipe. Ultrasonic two dimensional (2D) matrix phased array technology offers some unique advantages that make the technology promising for improving detection and sizing of pipeline flaws resulting from welding or from in-service damage. Ultrasonic modeling and simulation has been conducted to evaluate the detection and sizing capabilities of 2D matrix arrays for various pipeline inspection concepts. Simulations have been performed using both flexible and rigid array probes. Inspection concepts using rigid probes were evaluated for inspections from both the outside and inside pipe ...

2009-07-01

35

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

36

Experiments on determination of damage effect ions "2"2Ne (172 MeV) on UO_2 monocrystals  

International Nuclear Information System (INIS)

Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.

37

Early detection of damage and analysis of damage development in metal structural components. Schaedigungsfrueherkennung und Schadensablauf bei metallischen Bauteilen  

Energy Technology Data Exchange (ETDEWEB)

The topics of these short lectures on the subject of cyclic stress were: Microstructural mechanisms of damage accumulation under a multistage cyclic stress until incipient cracking; influence of surface decarbonizing phenomena on the failure behaviour of steel construction parts subjected to cyclic stress; thermocyclic fatigue of pipe samples of austenitic steel 1.4436; studies on surface structuring, microstructure and fatigue in LCF area. The short lectures on effects of quasi-static and creep stress were: Shear fracture in AlMg alloys as a result of local plastic instability; study of formation and growth of pores for an early recognition of damage and the course of damage in heat-resistant steels under creep test; experimental and numeric studies of the infuence of the microstructure on the course of damage during shear fractures of steel; numerical modelling of ductile fractures on the basis of ...

1989-01-01

38

The construction of earthquake damage estimation system for city gas supply system  

Energy Technology Data Exchange (ETDEWEB)

The regular occurrence of large-scale earthquakes in Japan necessitates the use of earthquake disaster prevention systems that focus on gathering damage information on gas supply facilities immediately after an earthquake strikes and minimizing the damage. This paper discussed the development of an earthquake damage estimation system for city gas pipelines that can show damage information in real-time by using earthquake records obtained from densely deployed earthquake observation networks and the most advanced telecommunication and information technologies. The paper summarized the earthquake damage estimation system (EDES) and Toho Gas disaster prevention measures. Specific topics that were discussed included the Toho Gas supply method; earthquake countermeasures; construction of computer systems; normal and emergency operation of EDES; and verification of ...

2010-07-01

39

Formation of damage symptoms to assess the safety margin of components in the high temperature range; Die Entwicklung von Schaedigungsmerkmalen zur Beurteilung der Sicherheitsspanne von Bauteilen im Hochtemperaturbereich  

Energy Technology Data Exchange (ETDEWEB)

Surface structure analysis, i.e. metallographic analysis of component surfaces with the aid of replicas, is an established method of component monitoring and the only reliable non-destructive method for detecting and analyzing beginning creep damage in the form of creep pores. Creep pore development provides a basis for component condition analysis. It must be noted, however, that the modern martensitic 9-12 % Cr steels - like the established steels 10CrMo9-10 (P22) und X20CrMoV12-1 - have comparatively high creep fracture deformation rates in fatigue tests. This raises the question if these steels can be judged on the basis of data for established steels. The results so far suggest that even with low pore densities (single pores), a higher degree of damage and a shorter time until failure must be assumed. [German] Eine bewaehrte Methode der Bauteilueberwachung ...

2005-07-01

40

Monitoring of DNA and cytogenetic damage in lymphocytes from persons with skin cancer diseases  

International Nuclear Information System (INIS)

There is a lot of interest in the studies that would help to understand whether there is a casual association between cancer and various types of molecular or cytogenetic damage detected in human cells. One major oncogenesis process is activation of proto-oncogenes by point mutations or chromosomal translocation. There are substantial evidence that indicates that the loss of heterozygosity of certain chromosomes is involved in human cancerogenesis. Our study aimed to elicit the possible association between cancer and DNA and cytogenetic abnormalities induced in lymphocytes of people bearing various categories of skin cancer cells. Fresh blood was collected by venipuncture from 25 individuals (including nine prior to cancer treatment). All patients were nonsmoking males, however 42.3 % of them were former smokers. Blood samples were divided into two parts and in the first part of samples cytogenetic studies were performed immediately, while from ...

2004-11-01

41

Theoretical review of techniques for the remote detection of methane in underground coal mines  

Energy Technology Data Exchange (ETDEWEB)

The nature and relationship of methane to coal mines is discussed and sources of information are outlined. Methods of gas analysis in general and methods for the detection of methane in use in coal mines are described. Methods of remote detection of gases and those that have application for use in underground coal mining operations are discussed. The report represents recommendations on remote methane detection systems that may find application in underground coal mines. (20 refs.)

1983-01-01

42

Development of a universal plate-agglutination test for detecting Haemophilus parasuis  

UK PubMed Central (United Kingdom)

Due to the serovar diversity in Haemophilus (H.) parasuis, it is difficult to develop a universal serological method for detection of this pathogen....Full Text Available

2010-12-01

43

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the contrast sensitivity test and to the Snellen ...

2002-01-01

44

First RAVEN flight set for September  

Energy Technology Data Exchange (ETDEWEB)

An unmanned aerial vehicle called RAVEN, said to be capable of remote tracking of onshore and offshore oil and gas facilities, has been developed by a group of graduate students from Memorial University of Newfoundland. RAVEN is claimed to be capable of performing a number of tasks under its own control without the need for human intervention, including checking onshore pipelines for damage, or scouting the path of hazardous icebergs offshore. The RAVEN was created to meet the need for real time iceberg tracking and early hazard detection, supplementing or replacing the present method of RADARSAT images and tracking by manned aircraft. The RAVEN can be launched from any platform; it can fly under conditions that would be too dangerous for a manned aircraft. Currently in the prototype stage, the first trial flight for the RAVEN is expected to take place in September 2002. The first flight will consist of five GPS waypoints ...

2002-08-01

45

Effects of post-irradiation annealing in alpha-particle bombarded molybdenum  

International Nuclear Information System (INIS)

Structural variations in 39-MeV alpha-particle irradiated (Tsub(irr) = 60 deg C) polycrystalline molybdenum during post-irradiation annealing were studied by X-ray and TEM methods. Despite the high density of irradiation induced defects in the structure of the specimen X-ray measurements showed zero relative lattice parameter change after an irradiation dose of 1.1 x 10"-_2 dpa. However, during the annealing #delta#a/a was changed in the positive range, exhibiting two peaks - at 100 and 300 deg C - whereas the damage structure detected by TEM indicated no changes. Analysis of the results leads to the conclusion that in the range 100 to 250 deg C migration of isolated vacancies and their annihilation at interstitial clusters as well as possible formation of new vacancy clusters occur. The second peak on the #delta#a/a temperature dependence curve is related to the transformation (probably, thermal disintegration) of vacancy ...

46

Detection and Toxin Typing of Clostridium perfringens in Formalin-Fixed, Paraffin-Embedded Tissue Samples by PCR?  

UK PubMed Central (United Kingdom)

Since current microbiology methods are not suitable to detect Clostridium perfringens in formalin-fixed, paraffin-embedded tissue samples, we developed a PCR assay to detect toxin-encoding...Full Text Available

2009-03-01

47

Detection and Identification of Ciprofloxacin-Resistant Yersinia pestis by Denaturing High-Performance Liquid Chromatography  

UK PubMed Central (United Kingdom)

Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available

2003-07-01

48

Method for detecting and diagnosing disease caused by pathological protein aggregation  

Energy Technology Data Exchange (ETDEWEB)

A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.

2000-05-16

49

BURST STRENGTH AND NON-DESTRUCTIVE EVALUTION OF COMPOSITE PIPES AND PIPE COUPLINGS WITH DEFECTS (TOP 48)  

Environmental Research Database

ObjectivesObjectives Not AvailableDescriptionTo determine the effects of water penetration on the burst strength of filament wound composite pipes which have been damaged by impact and then subjected to long term pressurisation with sea water. ~%~ To monitor and characterise the damage and effects of sea water penetration using ultrasonic NDT. To determine the burst strength of bonded composite pipe joints with and without defects and to see whether the defects can be detected using ultrasonic NDT. [continued...

1996-01-31

50

Rapid Detection of Ofloxacin Resistance in Mycobacterium tuberculosis by Two Low-Cost Colorimetric Methods: Resazurin and Nitrate Reductase Assays  

UK PubMed Central (United Kingdom)

We have evaluated the performance of two rapid, low-cost methods for the detection of ofloxacin (OFX) resistance with 95 Mycobacterium tuberculosis isolates from countries with high...Full Text Available

2005-04-01

51

Analysis of the Type IV Fimbrial-Subunit Gene fimA of Xanthomonas hyacinthi: Application in PCR-Mediated Detection of Yellow Disease in Hyacinths  

UK PubMed Central (United Kingdom)

A sensitive and specific detection method was developed for Xanthomonas hyacinthi; this method was based on amplification of a subsequence of the type IV fimbrial-subunit gene fimA...Full Text Available

2001-02-01

52

Response surface characterization of impact damage and residual strength degradation in composite sandwich panels  

Science.gov (United States)

The influence of material configuration and impact parameters on the damage tolerance characteristics of sandwich composites comprised of carbon-epoxy woven fabric facesheets and Nomex honeycomb cores was investigated using empirically based response surfaces. A series of carefully selected tests were used to isolate the coupled influence of various combinations of the number of facesheet plies, core density, core thickness, impact energy, impactor diameter, and impact velocity on the damage formation and residual strength degradation due to normal impact. The ranges of selected material parameters were typical of those found in common aircraft applications. The diameter of the planar damage area associated with Through Transmission Ultrasonic C-scan measurements and the peak residual facesheet indentation depth were used to describe the extent of internal and detectable surface ...

2003-01-01

53

Damage process and luminescent characteristics in silica glasses under ion irradiation  

International Nuclear Information System (INIS)

Full text of publication follows: Understanding the dynamic irradiation effects on silica glasses is important for developing the diagnostic systems used in fusion and fission environments. While fundamental defects having an un-pared electron such as the E' center have been extensively studied, the neutral oxygen deficiency defects have been insufficiently clarified for lack of the detection methods. The ion induced luminescence is one of the probes that can be used to detect non-paramagnetic defects, and to observe creation and annihilation behavior dynamically. In the present study, we examined the characteristics of the ion induced luminescence such as energy, fluence flux and temperature dependence of the luminescence efficiency to analyze damage process quantitatively. Samples of SiO2 glasses were commercially available fused and synthesized silica glasses, produced by Toshiba Ceramics, Co. Ltd.. ...

2007-12-10

54

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

55

Economic assessment of air pollution. Economic evaluation of the effects of air pollution  

Energy Technology Data Exchange (ETDEWEB)

The cost incurred every year in West Germany due to air pollution is investigated. Damage to buildings, materials, and vegetation are evaluated as well as the cost of additional cleaning work and changes of location with the objective of getting a picture of the economic value of air pollution abatement. The findings are based on data of immission damage in high-exposure areas. Damage is assessed in consideration of the frequency of repair measures in industrial and country atmosphere. Further research will be necessary in view of the many problems concerning methods and availability of basic statistical data. The sequential cost estimated for a few selected cases of damage show that economic losses due to air pollution amount to several thousand million DM. Air pollution abatement measures thus do not only improve our quality of life but also help to save considerable cost to our ...

1980-01-01

56

The effects of surface damage on RF cavity operation  

Energy Technology Data Exchange (ETDEWEB)

We describe a model of damage in rf cavities and show how this damage can limit cavity operation. We first present a review of mechanisms that may or may not affect the ultimate fields that can be obtained in rf cavities, assuming that mechanical stress explains the triggers of rf breakdown events. We present a method of quantifying the surface damage caused by breakdown events in terms of the spectrum of field enhancement factors, Beta, for asperities on the surface. We then model an equilibrium that can develop between damage and conditioning effects, and show how this equilibrium can determine cavity performance and show experimental evidence for this mechanism. We define three functions that quantify damage, and explain how the parameters that determine this performance can be factored out and measured. We then show how this model can quantitatively explain ...

2006-04-14

57

Detection and classification of bearing flaking using kullback discrimination information; Kullback shikibetsu johoryo (KDI) wo mochiita jikuuke no tendomen hakuri no kenchi to shikibetsu  

Energy Technology Data Exchange (ETDEWEB)

Since bearing is in wide use as basic parts for rotary machines, detection and diagnosis of its defects are important in practical use. To discriminate defect portions by early detection of roller bearing flaking, the conventional parameter method using peakedness is poor. Thus to directly obtain difference in waveform, the new method was applied to such detection which uses KDI as the scale of a difference in waveform, and a most neighborhood classification rule based on KDI. The detection and discrimination abilities of this method was studied mainly in experiment. The experiment used a bench scale rotor and a supporting bearing, and attempted detection and discrimination of no flaking, outer ring flaking and inner ring flaking. As a result, this method could detect and ...

1998-06-15

58

Preliminary studies of tunnel interface response modeling using test data from underground storage facilities.  

Energy Technology Data Exchange (ETDEWEB)

In attempting to detect and map out underground facilities, whether they be large-scale hardened deeply-buried targets (HDBT's) or small-scale tunnels for clandestine border or perimeter crossing, seismic imaging using reflections from the tunnel interface has been seen as one of the better ways to both detect and delineate tunnels from the surface. The large seismic impedance contrast at the tunnel/rock boundary should provide a strong, distinguishable seismic response, but in practice, such strong indicators are often lacking. One explanation for the lack of a good seismic reflection at such a strong contrast boundary is that the damage caused by the tunneling itself creates a zone of altered seismic properties that significantly changes the nature of this boundary. This report examines existing geomechanical data that define the extent of an excavation damage zone around underground tunnels, ...

2010-11-01

59

On the water-chemical regime in steam generators at NPP  

British Library Electronic Table of Contents (United Kingdom)

The effect of the water-chemical regime (WCR) on damage sustained by heating surfaces of steam generators at NPP is analyzed. It is indicated that phosphate treatment with minimal excesses of phosphates in the steamgenerator water is the most optimal method of managing the WCR regime of horizontal steam generators.

2006-01-01

60

Measurements of accurate x-ray scattering data of protein solutions using small stationary sample cells  

UK PubMed Central (United Kingdom)

In this paper, we report a method of precise in situ x-ray scattering measurements on protein solutions using small stationary sample cells. Although reduction in the radiation damage...Full Text Available

2009-01-01

61

Development and credibility assessment of a metamodel relating water table depth to agricultural production  

British Library Electronic Table of Contents (United Kingdom)

Phreatic groundwater pumping is affecting water availability for crops in areas with a shallow water table. This can reduce crop growth and so affect farm income. There is a need for a generic and transparent method to assess the agricultural damage caused by water table drawdown. This paper proposes such a method that consists of 'damage tables' relating agricultural production losses to the groundwater regime for different soil/crop combinations found in Northern Belgium. The damage tables are constructed based on numerous simulations with the agrohydrological model SWAP, in which the bottom boundary conditions are gradually changed to reflect different groundwater regimes. The credibility of the resulting metamodel is assessed in three ways: using (1) field data, (2) an existing local e...

2010-01-01

62

"9"9"mTechnetium-heat damaged erythrocyte spleen scan  

International Nuclear Information System (INIS)

"9"9"mTechnetium -heat damaged erythrocyte were used as spleen scanning agents in 12 patients from July, 1985 to April, 1986. We used this scan to evaluate situs inversus, asplenia, accessory spleen, hypersplenism, splenic infarction, tumor staging and evaluation of therapy, especially when the "9"9"mTc-tin colloid scans were not definite for diagnosis. The techniques applied to these scans were in vivo/in vitro-labeling method and heating-method to damage the erythrocytes. Liver-to-spleen uptake ratios were increased upto 100:1 and interference from the left lobe of the liver was eliminated. These scans were helpful to evaluate the spleen. (Author).

63

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

64

Comparison of fluorescence in situ hybridisation using peptide nucleic acid probes, Gram stain/acridine orange leukocyte cytospin and differential time to positivity methods for detection of catheter related bloodstream infection in patients after haematopoietic stem cell transplantation  

British Library Electronic Table of Contents (United Kingdom)

Abstract In 46 febrile neutropenic patients who had undergone haematopoietic stem cell transplantation, the fluorescence in situ hybridisation using peptide nucleic acid probes (PNA FISH), Gram stain/acridine orange leukocyte cytospin (Gram/AOLC), and differential time to positivity (DTP) methods were performed for detection of catheter related bloodstream infections (CRBSIs). As compared with the DTP method (which detected 11 patients with CRBSI), the PNA FISH and the Gram/AOLC methods detected ten of 11 CRBSI patients, resulting in a sensitivity, specificity, negative predictive value and positive predictive value of 91%, 100%, 97% and 100%, respectively, for the PNA FISH method as well as for the Gram/AOLC method.

2010-01-01

65

Rapid Detection of Ophiostoma piceae and O. quercus in Stained Wood by PCR  

UK PubMed Central (United Kingdom)

A rapid, sensitive, and simple method was developed to detect the sapstain fungi Ophiostoma piceae and O. quercus in stained wood. By using microwave heating for DNA...Full Text Available

1999-01-01

66

Immunoquantitative Real-Time PCR for Detection and Quantification of Staphylococcus aureus Enterotoxin B in Foods  

UK PubMed Central (United Kingdom)

A real-time immunoquantitative PCR (iqPCR) method for detection of Staphylococcus aureus enterotoxin B (SEB) was developed and evaluated using both pure cultures and foods. The assay...Full Text Available

2006-10-01

67

Evaluation of Colorimetric Methods Using Nicotinamide for Rapid Detection of Pyrazinamide Resistance in Mycobacterium tuberculosis?  

UK PubMed Central (United Kingdom)

The direct detection of pyrazinamide resistance in Mycobacterium tuberculosis is sufficiently difficult that many laboratories do not attempt it. Most pyrazinamide resistance is caused...Full Text Available

2010-08-01

68

Enzyme amplified immunoassay: a novel technique applied to direct detection of Chlamydia trachomatis in clinical specimens.  

UK PubMed Central (United Kingdom)

Endocervical swabs from 212 women and urethral swabs from 100 men were tested by the routine methods for McCoy cell culture and simultaneously by a novel enzyme amplified immunoassay test to detect...Full Text Available

1985-10-01

69

Diarrheal Illness Detected Through Syndromic Surveillance After a Massive Power Outage: New York City, August 2003  

UK PubMed Central (United Kingdom)

Objectives. We investigated increases in diarrheal illness detected through syndromic surveillance after a power outage in New York City on August 14, 2003.Methods....Full Text Available

2006-03-01

70

Detection of cellular responses to toxicants by dielectrophoresis  

UK PubMed Central (United Kingdom)

The dielectrophoretic (DEP) crossover method has been applied to the detection of cell responses to toxicants. Time and dose responses of the human cultured leukemia (HL-60) line were measured...Full Text Available

2002-08-31

71

Cavity detection by the electric method: the 3-dimensional case  

Energy Technology Data Exchange (ETDEWEB)

In this paper the authors prove a uniqueness theorem for the electric detection of cavities in a three dimensional solid from Cauchy data measured on the surface. The cavities, finite in number, are assumed to be insulating. The surfaces of the cavities are assumed to be smooth on the complement of a set that is, in some sense, negligible. (orig.)

2004-02-01

72

A faster pedigree-based generalized multifactor dimensionality reduction method for detecting gene-gene interactions  

UK PubMed Central (United Kingdom)

We proposed a faster pedigree-based generalized multifactor dimensionality reduction algorithm, called PedG-MDR II (PII), to detect gene-gene interactions underlying complex traits. Inherited...Full Text Available

2011-01-01

73

The influence of prior ageing on creep damage development in two variants of Alloy 800  

Energy Technology Data Exchange (ETDEWEB)

The influence of high temperature thermal ageing treatments on the development of intercrystalline creep damage in two variants of Alloy 800 has been investigated. Ageing up to 3000 h and creep testing were carried out at 800 and 900 C. The high temperature behaviour of the 800HT variant is discussed with reference to the effect of heat treatments on the microstructure. The metallographic methods by which the creep damage was quantitatively determined are described. The growth rate of intercrystalline microcracks was described using a statistical model and the dependence of crack growth rate on the thermal history for both 800HT and 800H was determined. The carbide precipitation and growth processes were determined as functions of the exposure temperature and duration. The results showed the three characteristic stages, precipitation, growth and coarsening (Ostwald ripening). The largest increase in the intergranular creep ...

1997-06-01

74

An immunochemical approach to the study of DNA damage and repair. Technical progress report, May 1, 1989--April 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies ...

1992-05-01

75

An immunochemical approach to the study of DNA damage and repair  

Energy Technology Data Exchange (ETDEWEB)

The overall objective of this project has been to develop immunochemical methods to quantitate unique DNA base damages in order to facilitate studies on radiation-induced damage production and repair. Specifically, we have been using antibodies raised to damaged bases to quantitate unique lesions in model systems in order to evaluate their potential biological consequences. Our approach has been to synthesize modified nucleotides or nucleosides, conjugate them to protein carriers, and use the conjugates as immunogens in rabbits or to prepare monoclonal antibodies. We have been studying damages that are stable radiolysis products found in X-irradiated DNA and thus of potential biological consequence. Our aim is to build an in vitro and in vivo data base on the interactions between model DNA lesions and such cellular enzymes as DNA polymerases and repair endonucleases. Initial studies ...

1992-05-01

76

Analysis of thermoluminescence glow curves of minerals sphene and epidote for radiation damage studies  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the ...

1986-01-01

77

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...

2002-03-01

78

Method and device for identifying different species of honeybees  

Energy Technology Data Exchange (ETDEWEB)

A method and device have been provided for distinguishing Africanized honeybees from European honeybees. The method is based on the discovery of a distinct difference in the acoustical signatures of these two species of honeybees in flight. The European honeybee signature has a fundamental power peak in the 210 to 240 Hz range while the Africanized honeybee signature has a fundamental power peak in the 260 to 290 Hz range. The acoustic signal produced by honeybees is analyzed by means of a detecting device to quickly determine the honeybee species through the detection of the presence of frequencies in one of these distinct ranges. The device includes a microphone for acoustical signal detection which feeds the detected signal into a frequency analyzer which is designed to detect the presence of either of the known fundamental wingbeat ...

1989-01-01

79

Rapamycin (sirolimus) protects against hypoxic damage in primary heart cultures via Na^+/Ca^2^+ exchanger activation  

British Library Electronic Table of Contents (United Kingdom)

Aims: Rapamycin (sirolimus) is an antibiotic that inhibits protein synthesis through mammalian targeting of rapamycin (mTOR) signaling, and is used as an immunosuppressant in the treatment of organ rejection in transplant recipients. Rapamycin confers preconditioning-like protection against ischemic-reperfusion injury in isolated mouse heart cultures. Our aim was to further define the role of rapamycin in intracellular Ca^2^+ homeostasis and to investigate the mechanism by which rapamycin protects cardiomyocytes from hypoxic damage. Main methods: We demonstrate here that rapamycin protects rat heart cultures from hypoxic-reoxygenation (H/R) damage, as revealed by assays of lactate dehydrogenase (LDH) and creatine kinase (CK) leakage to the medium, by MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-d...

2011-01-01

80

Impact of Collateral Damage to Endourologic Tools During Laser Lithotripsy???In Vitro Comparison of Three Different Clinical Laser Systems  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background and Purpose: During laser lithotripsy, working instruments are often in close proximity to the distal fiber tip and may be damaged accidentally or even intentionally. The aim of this study was to compare the amount of damage to a standard guidewire and the nitinol wires of endourologic retrieval baskets that were affected by three different clinically available laser systems. Materials and Methods: The impact of pulsed laser irradiation on a standard hydrophilic guidewire and a retrieval basket were investigated. One infrared (IR) laser system (holmium:yttrium-aluminum-garnet [Ho:YAG]: ????=???2100???nm) and two laser systems emitting light in the visible (VIS) spectral range (frequency-doubled double-pulse neodymium:YAG [FREDDY]: ????=???532???nm/1064???nm and flashl...

2011-01-01

81

Development and analysis of stage-damage curves for the Kum River basin  

Energy Technology Data Exchange (ETDEWEB)

In the flood surveys, it is fundamental to set up the relations of stage-damage. And this makes it possible to evaluate the flood regulation effects of the multipurpose dam and/or levee construction for optimum formulation. Unfortunately in the previous basin studies excluding the Han river basin survey, the conventional approaches on this matter have not been performed due to its time-consuming complexity. In this study we attempted a new method based on the disaster status, and constructed six stage-damage curves along the reaches of the Kum river basin, based upon the flood events records for recent 12 years (1981-92). (author). 12 refs., 3 tabs., 13 figs.

1996-10-31

82

Tetracycline ulcers of the oesophagus  

Energy Technology Data Exchange (ETDEWEB)

Two cases of tetracycline ulcers of the oesophagus are reported and compared with thirteen other cases from the literature. In most cases, the patients had taken their capsules with little or no fluid just before going to bed. Some hours later they developed retrosternal pain that was intensified by swallowing. Endoscopy showed sharply demarcated greyish-white areas of mucosal damage which represented layers of stratified squamous cells, separated by oedema, and a dense neutrophilic infiltration of the lamina propria and the muscularis mucosa. Roentgenology was unsuitable to detect the lesions. They healed without complications within one to six weeks. Prolonged retention of the capsules in the oesophagus is thought to cause the mucosal damage. Patients on oral tetracycline or doxycycline treatment should therefore be instructed to take their capsules with a meal or with copious water and not just before going to bed.

1981-11-01

83

Cooperative use of unmanned sea surface and micro aerial vehicles at Hurricane Wilma  

British Library Electronic Table of Contents (United Kingdom)

On Oct. 24, 2005, Hurricane Wilma, a category 5 storm, made landfall at Cape Romano, Florida. Three days later, the Center for Robot-Assisted Search and Rescue at the University of South Florida deployed an iSENYS helicopter and a prototype unmanned water surface vehicle, AEOS-1, to survey damage in parts of Marco Island, 14 km from landfall. The effort was the first known use of unmanned sea surface vehicles (USVs) for emergency response and established their suitability for the recovery phase of disaster management by detecting damage to seawalls and piers, locating submerged debris (moorings and handrails), and determining safe lanes for sea navigation. It provides a preliminary domain theory of postdisaster port and littoral inspection with unmanned vehicles for use by the human-robot ...

2008-01-01

84

The detection and characterization of natural fractures using P-wave reflection data, multicomponent VSP, borehole image logs and the in-situ stress field determination  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this project are to detect and characterize fractures in a naturally fractured tight gas reservoir, using surface seismic methods, borehole imaging logs, and in-situ stress field data. Further, the project aims to evaluate the various seismic methods as to their effectiveness in characterizing the fractures, and to formulate the optimum employment of the seismic methods as regards fracture characterization.

1995-04-01

85

Plagiarism Detection in arXiv  

CERN Document Server

We describe a large-scale application of methods for finding plagiarism in research document collections. The methods are applied to a collection of 284,834 documents collected by arXiv.org over a 14 year period, covering a few different research disciplines. The methodology efficiently detects a variety of problematic author behaviors, and heuristics are developed to reduce the number of false positives. The methods are also efficient enough to implement as a real-time submission screen for a collection many times larger.

2007-01-01

86

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

87

Helium atom doping of molybdenum and its influence on the radiation hardenings  

International Nuclear Information System (INIS)

Experimental results on study of helium concentration influence on degree of molybdenum radiation hardening for various method of cyclotron doping differing in degree and damage character are presented. It is established that accumulation of helium atoms in molybdenum for simultaneous formation of radiation defects caused by low energetic primary-knocked atoms leads to higher degree of hardening than for high energetic ion irradiation. It is shown that with increase of helium atom concentration the degree of radiation hardening for the same level of damage increases. 4 refs.; 3 figs. (author).

1990-05-22

88

Infrared radiation features of coal and rocks under loading  

Energy Technology Data Exchange (ETDEWEB)

Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, ...

1998-10-01

89

Colonoscopy  

Medline Plus

... experts agree-- a colonoscopy is the most accurate test to detect the cancer, but because of cost ... method. Dr. Randall Burt: Colonoscopy is the best test. The question is therefore shouldn't everyone, since ...

90

Asymmetric Totally-corrective Boosting for Real-time Object Detection  

CERN Document Server

Real-time object detection is one of the core problems in computer vision. The cascade boosting framework proposed by Viola and Jones has become the standard for this problem. In this framework, the learning goal for each node is asymmetric, which is required to achieve a high detection rate and a moderate false positive rate. We develop new boosting algorithms to address this asymmetric learning problem. We show that our methods explicitly optimize asymmetric loss objectives in a totally corrective fashion. The methods are totally corrective in the sense that the coefficients of all selected weak classifiers are updated at each iteration. In contract, conventional boosting like AdaBoost is stage-wise in that only the current weak classifier's coefficient is updated. At the heart of the totally corrective boosting is the column generation technique. Experiments on face detection ...

2010-01-01

91
92

A multidimensional hybrid intelligent method for gear fault diagnosis  

British Library Electronic Table of Contents (United Kingdom)

Identifying gear damage categories, especially for early faults and combined faults, is a challenging task in gear fault diagnosis. This paper proposes a new multidimensional hybrid intelligent diagnosis method to identify different categories and levels of gear damage automatically. In this method, Hilbert transform, wavelet packet transform (WPT) and empirical mode decomposition (EMD) are performed on gear vibration signals to extract additional fault characteristic information. Then, multidimensional feature sets including time-domain, frequency-domain and time-frequency-domain features are generated to reveal gear health conditions. Multiple classifiers based on several classification algorithms and input features are combined with genetic algorithm (GA). Because of the use of multidim...

2010-01-01

93

Limitation of immunohistochemical localization of estrogen receptor  

Energy Technology Data Exchange (ETDEWEB)

Although the radioreceptor method is widely used for estrogen receptor assay in human tissue, it has several limitations and a number of alternative methods are being explored. An immunohistochemical method of estrogen receptor assay using a specific antibody to estradiol has been proposed as a suitable alternative. The present study was designed to evaluate the validity of this method in detecting true estrogen receptors in human tumor tissue. Using radioiodinated antibody to estrogen, we have demonstrated that the estrogen antibody can detect the estrogen when it is bound to 4S type receptor but is unable to bind to estrogen when the hormone is bound to 8S type receptor. Our observations suggest that the immunohistochemical method of detection of intracellular cytosolic receptor for estrogen is not a suitable ...

1986-10-01

94

Eddy current signal analysis techniques for assessing degradation of support plate structures in nuclear steam generators  

Energy Technology Data Exchange (ETDEWEB)

The steam generator (SG) is one of the most critical components of the heat transfer system in nuclear generation stations. Testing the structural integrity of SG tubing and SG internals is a key element of the fitness-for-service assessments to assure the safe and continuous operation of nuclear power plants. Recent eddy current (ET) inspections of two nuclear power plants revealed degradation of some of the tube support plate (TSP) structures, which was also confirmed by visual inspection. The phenomena was described as metal loss, caused by flow-accelerated corrosion of the carbon steel trefoil support plate and varying from minor to complete loss of the ligaments. This loss of TSP ligaments results in lack of support for the adjacent tubes making them more susceptible to fretting-wear damage and fatigue cracking. A signal analysis method, based on the responses at low frequency of two types of eddy current probes, has been developed to ...

2006-07-01

95

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features; Modificazioni anatomiche dopo chirurgia radicale e ricostruzione con lembi peduncolati o rivascolarizzati nei tumori cervico-facciali negli stadi avanzati: Aspetti con Tomografia Computerizzata e Risonanza Magnetica  

Energy Technology Data Exchange (ETDEWEB)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened layers with both imaging ...

1997-04-01

96

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features  

International Nuclear Information System (INIS)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened layers with both imaging ...

1997-01-01

97

Supernova Neutrinos Detection On Earth  

CERN Document Server

In this paper, we first discuss the detection of supernova neutrino on Earth. Then we propose a possible method to acquire information about $\\theta_{13}$ smaller than $1.5^\\circ$ by detecting the ratio of the event numbers of different flavor supernova neutrinos. Such an sensitivity cannot yet be achieved by the Daya Bay reactor neutrino experiment.

2009-01-01

98

Detection of Atopobium vaginae in postmenopausal women by cultivation-independent methods warrants further investigation.  

Science.gov (United States)

We sequenced 16S rRNA genes from the vaginal swab contents of a postmenopausal woman with asymptomatic bacterial vaginosis (BV). Sequences from Atopobium vaginae were the most commonly detected. In a survey of 35 other postmenopausal women, this organism was detected in 44% with BV but not in any subjects deemed healthy. PMID:15071062

2004-04-01

99

Dependence of anomalous phosphorus diffusion in silicon on depth position of defects created by ion implantation  

Energy Technology Data Exchange (ETDEWEB)

Transient enhanced diffusion of phosphorus in silicon has been investigated for implants below and above the threshold for a complete amorphization. Rapid thermal processes (electron beam) and conventional furnaces have been used for the annealing. In the case of implants below amorphization, a strong enhanced diffusion, proportional to the amount of damage produced, has been observed. The extent of the phenomenon is practically independent of the damage depth position. In contrast to this, the formation of extended defects at the original amorphous-crystalline interface makes the diffusivity strongly dependent on depth in the case of post-amorphized samples. No enhanced diffusion effect is observed if the dopant is confined in the amorphous layer, while a remarkable increase in the diffusivity is detected for the dopant located in the crystalline region beyond the amorphous-crystalline interface. ...

1989-03-01

100

Detection of intracardiac calcification using Fuji computed radiography  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).

1986-01-01

101

Oil-filled cable surveillance system using newly developed optical fiber gas sensor  

Energy Technology Data Exchange (ETDEWEB)

A new surveillance system for Oil-Filled cable, which can provide continuous monitoring, using a newly developed optical gas sensor that can detect the concentration of the gas dissolved in the oil with extremely high sensitivity has been developed. It was proved that the degree of deterioration of the insulating oil can be detected by measuring C{sub 2}H{sub 2} and CH{sub 4} by investigating the relation between the degree of deterioration and amount of combustible gas generated. In order to detect extremely small amounts of gas, a new gas detecting method using absorption line of the gas using a frequency modulated technique has been developed. The gas detection ability was also confirmed by examination using a 66 kV of cable and the possibility of detection at an early stage is expected.

1996-04-01

102

CT assessment of thoracic gunshot wounds. Our personal experience; Ruolo della Tomografia Computerizzata nelle lesioni da arma da fuoco del torace. Esperienza personale  

Energy Technology Data Exchange (ETDEWEB)

CT is a valuable tool in assessing thoracic gunshot wounds. CT is also the method of choice in emergency, because it permits rapid depiction of bullet damage to the chest and to other body districts. This in turn permits correct assessment of the main thoracic injuries, plus adequate and prompt planning of surgical treatment or support intensive care. It is reported on the role of CT in diagnosing the complex pleuropulmonary, cardiovascular and thoracic wall injuries caused by gunshot wounds, with their specific and acute signs which differ greatly fro those of other types of chest trauma. In the last 4 years, it was observed an amount of 76 cases of gunshot injury, twenty-six of them involved the chest. The patients, 25 men and 1 woman (mean age: 32 years, range: 17-48), were all submitted to emergency CT with iv contrast agent injection and the CT-angiography technique. The reanimator was always presented to monitor the patients' ...

1999-11-01

103

Detection of mice lung cancer by neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).

1995-11-01

104

Full scale testing of wind turbine blade to failure - flapwise loading  

Energy Technology Data Exchange (ETDEWEB)

A 25m wind turbine blade was tested to failure when subjected to a flapwise load. With the test setup, it was possible to test the blade to failure at three diffe-rent locations. The objective of these tests is to learn about how a wind turbine blade fails when exposed to a large flapwise load and how failures propagate. The report shows also results from ultra sonic scan of the surface of the blade and it is seen to be very useful for the detection of defects, especially in the layer between the skin laminate and the load carrying main spar. Acoustic emission was successfully used as sensor for the detection of damages in the blade during the test. The report contains measurements of the total deflection of the blade, the local deflection of the skin and the load carrying main spar and also measurement of strain all as a function of the applied load and up to failure of the blade. The 'post mortem' ...

2004-06-01

105

Effects of focused ion beam milling on the nanomechanical behavior of a molybdenum-alloy single crystal  

International Nuclear Information System (INIS)

Nanoindentation was performed on a Mo-alloy single crystal to investigate effects of focused ion beam (FIB) milling on mechanical behavior. On a non-FIB-milled surface, pop-ins were observed on all load-displacement curves corresponding to a transition from elastic to plastic deformation. Similar pop-ins were not detected on surfaces subjected to FIB milling. This difference indicates that FIB milling introduces damage that obviates the need for dislocation nucleation during subsequent deformation. A second effect of FIB milling is that it increased the surface hardness. Together, these effects could be the source of the size effects reported in the literature on micropillar tests.

2007-09-10

106

Dentascan CT of mandibular incisive canal. Radiological anatomy and therapeutic implications  

International Nuclear Information System (INIS)

The main purpose of this paper is to stress the importance of CT depiction of the mandibular incisive canal. This anatomical structure contains a major neurovascular bundle and is thus very important in the planning of mandibular implants in the canine-incisive area. The importance of careful assessment of the mandibular canal course before implantology is now widely recognized. The same holds true for the canine-incisive region in the jaw, to detect the incisive canal if present and prevent any complications from its accidental damage. CT with a dedicated software showed the incisive canal in a large number of patients, which calls for precise reporting of its presence, course, and relationships with teeth.

1999-11-01

107

Damage tolerance of metalic structures  

Energy Technology Data Exchange (ETDEWEB)

This Workpackage Report describes the introduction of fatigue cracks in bolts with ISO-metric threads M5x0.8, M8x1.0, M12x1.25 made from the materials Ti 6Al 4V, A-286 and INCONEL 718. Introdued cracks are verified by destructive testing. Results of the NDI of these bolts performed with special eddy current probes are reported. The detectability of cracks with a {>=} 0.65 and a/2c {approx equal} 0.3 located in the thread ground perpendicular to the load axis is demonstrated. (orig.).

1991-01-01

108

Particle identification by modified Bragg-curve centroid detection  

Energy Technology Data Exchange (ETDEWEB)

A new article identification method based on the measurement of Bragg-curve centroids using a gas-filled ionization chamber has been improved for detection of low-energy particles around 1 MeV per nucleon by introducing a nonuniform distribution of resistance on the anode electrode. Almost the same quality of Z-resolutions as in the conventional ..delta..E-E method could be obtained up to Z=19.

1987-03-01

109

Method and apparatus for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method and apparatus is provided for detecting explosives by thermal imaging. The explosive material is subjected to a high energy wave which can be either a sound wave or an electromagnetic wave which will initiate a chemical reaction in the explosive material which chemical reaction will produce heat. The heat is then sensed by a thermal imaging device which will provide a signal to a computing device which will alert a user of the apparatus to the possibility of an explosive device being present.

2011-05-10

110

Comparison of C18-Carboxypropylbetaine and Glass Bead DNA Extraction Methods for Detection of Mycobacterium bovis in Bovine Milk Samples and Analysis of Samples by PCR  

UK PubMed Central (United Kingdom)

The purpose of this prospective study was to compare two different milk preparation methods to assay for the presence of Mycobacterium bovis by PCR. Detection by a C18-carboxypropylbetaine...Full Text Available

1998-08-01

111

Structural health monitoring of constrained tapered beamlike structures using natural frequencies and nodal points  

Science.gov (United States)

The integrity and safety of beam-like structures are dependent in part on their boundary conditions which can vary with time due to damage or aging. Structural health monitoring of such structures should therefore include attention to boundary conditions. Where the boundary conditions can be represented by a lumped spring then the identification of associated stiffness parameter values may be a means to quantifying the integrity of the support. This paper investigates such a method for identifying the equivalent translational and rotational stiffness of a constrained tapered beam-like structure. An analytical model of a beam of tapered width and thickness is adopted as a simplified representation of a tower-like structure. The model is used to explore in what scenarios natural frequencies and/or nodal points might be sufficiently sensitive to changes in support conditions to be measurable indicators of damage. The ...

2011-07-01

112

A multi-marker model for detecting chromosomal segments displaying QTL activity  

Science.gov (United States)

A statistical method is presented for detecting quantitative trait loci (QTLs), based on the linear model. Unlike methods able to detect a few well separated QTLs and to estimate their effects and positions, this method considers the genome as a whole and enables the detection of chromosomal segments involved in the differences between two homozygous lines, and their backcross, doubled haploid, or F[sub 2] progenies, for a quantitative trait. Genetic markers must be codominant, but missing markers are accepted, provided they are missing independently from the experiment. Asymptotic properties, which are of practical use, are developed. This method does not rely on strong genetic hypotheses, and thus does not permit any precise genetic analysis of the trait under study, but it does assess which regions of the genome are involved, whatever the ...

1993-08-01

114

Power cables: methods of defects localization; Cables d'energie: methodes de localisation des defauts  

Energy Technology Data Exchange (ETDEWEB)

The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)

2006-08-15

115

Experimental studies on a structure of eddy current probe for detection of magnetic flux disturbed by a flaw  

International Nuclear Information System (INIS)

Bobbin-coil-type eddy current probes, which are conventionally used for nondestructive inspection of steam generator tubes in pressurized-water-type nuclear power plants, have poor detectability for circumferential flaws. Hence a new type of eddy current probe was proposed to detect effectively the magnetic flux component disturbed by a flaw and thus to eliminate the flaw direction dependency on the flaw detectability. In the course of development of the proposed method, structures of the probe were investigated based on the measurement of magnetic fields induced by exciting flat coils with several shapes. The new type of probe proposed here consists of differential pick-up coils detecting magnetic flux and exciting coils having a parallelogrammic shape, and its structure was fabricated experimentally in order to detect flaws independently of their directions. ...

1995-01-01

116

An effective method to estimate multidimensional Gaussian states  

CERN Document Server

A simple and efficient method for characterization of multidimensional Gaussian states is suggested and experimentally demonstrated. Our scheme shows analogies with tomography of finite dimensional quantum states, with the covariance matrix playing the role of the density matrix and homodyne detection providing Stern-Gerlach-like projections. The major difference stems from a different character of relevant noises: while the statistics of Stern-Gerlach-like measurements is governed by binomial statistics, the detection of quadrature variances correspond to chi-square statistics. For Gaussian and near Gaussian states the suggested method provides, compared to standard tomography techniques, more stable and reliable reconstructions. In addition, by putting together reconstruction methods for Gaussian and arbitrary states, we obtain a tool to detect the ...

2009-01-01

117

Giant magnetoresistance sensing technologies for detecting small defects in metallic structures  

Science.gov (United States)

Giant magnetoresistance (GMR) has been used with Eddy current testing to detect small defects not only in thin film structures but also in multilayered metallic structures. This work detected small scratches in the thin film under the surface where these defects were unable to be inspected or monitored by regular testing. In addition, rotational GMR magnetic sensor based Eddy current probes were used for detecting buried corner cracks at the edge of holes in metallic structures. The results of this study proved that giant magnetoresistance is very powerful and effective to sense the magnetic field, which is the result from the perturbation of the Eddy currents caused by a defect. This method can be used for quality control of metallization layers on silicon wafer and to detect cracks in thick structures such as cracks in aging aircraft.

2008-01-01

118

Fuel injection control for diesel engine  

Energy Technology Data Exchange (ETDEWEB)

A method is described for controlling fuel injection in a diesel engine having a fuel injection nozzle, comprising the steps of: detecting an idling state of the diesel engine and pressure in a combustion chamber; obtaining a pressure increment rate from the pressure detected by the detecting step; selecting a valve opening pressure of the fuel injection nozzle at a relatively low level when the idling state is detected by the detecting step, thereby setting a two peaks characteristics of a fuel injection rate; and controlling the fuel injection nozzle in response to the pressure increment rate so that the pressure increment rate in the combustion chamber is maintained within a predetermined value by changing a fuel injection quantity of a pilot injection from the fuel injection nozzle.

1987-11-10

119

Simultaneous ultraviolet spectrophotometric determination of nitrate and nitrite in water  

Energy Technology Data Exchange (ETDEWEB)

A rapid and accurate method for the direct simultaneous determination of nitrate and nitrite is proposed. The method is applied to the determination of nitrate and nitrite in rainwater and wastewater without preliminary separation. The determinations are performed by a CPA matrix method with ultraviolet spectrophotometric detection. The results obtained are in agreement with those obtained by conventional methods for the determination of nitrate and nitrite.

1991-02-01

120

Determination of lead in biological and environmental samples by "2"0"3Pb isotope dilution substoichiometric method  

International Nuclear Information System (INIS)

A procedure for the determination of lead in various biological and environmental samples by "2"0"3Pb radioisotope dilution substoichiometric method is presented. The accuracy of the method by comparison with the literature values of reference materials appears to be good. The standard deviation of the method is less than 10%, and detection limit is about 0.1 #mu#g of lead. (author) 5 refs.

121

Comparison of Ceramic, Metal and Polymer Crevice Formers on the Crevice Corrosopn Behavior of Ni-CR-Mo Alloy C22  

Energy Technology Data Exchange (ETDEWEB)

A necessary condition for crevice corrosion is that a crevice former create a sufficiently tight, restricted geometry on the metal surface to support the development of critical crevice chemistry. Crevice corrosion is affected by the crevice geometry (tightness) and the properties of the crevice former. The objective of this study is to determine the effect of the crevice former material on the evolution of localized corrosion-damage. A standard crevice corrosion test method is modified by (a) the use of ceramic, metal or polymer materials as the crevice former and (b) the variation of size and shape of the crevice. This study focuses on the post initiation stage of crevice corrosion and addresses factors that may limit the initiation of localized corrosion and also slow or stop the continued propagation of corrosion. Controlled crevice corrosion tests are performed under aggressive, accelerated conditions on Ni-Cr-Mo alloy C-22 and other ...

2006-05-08

122

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

123

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

124

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

125

A quantitative method to detect explosives and selected semivolatiles in soil samples by Fourier transform infrared spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a novel Fourier transform infrared (FTIR) spectroscopic method that can be used to rapidly screen soil samples from potentially hazardous waste sites. Samples are heated in a thermal desorption unit and the resultant vapors are collected and analyzed in a long-path gas cell mounted in a FTIR. Laboratory analysis of a soil sample by FTIR takes approximately 10 minutes. This method has been developed to identify and quantify microgram concentrations of explosives in soil samples and is directly applicable to the detection of selected volatile organics, semivolatile organics, and pesticides.

1995-06-01

126

Significance of cranial computer tomography for the early diagnosis of peri- and postnatal damage  

Energy Technology Data Exchange (ETDEWEB)

It is reported on examination-technical possibilities with craniocerebral Computer Tomography in the peri- and postnatal period. Some typical tomographic images from a 17 1/2 months period in our own patient material of 327 children are demonstrated. The special advantages of this new technical-extensive method are: exact diagnoses, observation possibility of the longitudinal section, and the absolute harmlessness to the child.

1981-01-01

127

Risk-orientated analysis of the SNR 300. Technical report 1  

International Nuclear Information System (INIS)

The study required by the West German Ministry of Research and Technology (RS 605) for the Committee on 'Future Nuclear Energy Policy' of the 9th German Parliament is concerned with the following main points: 1) Assessment of technical risks from the social aspect; 2) Discussion of terms and quantification of risks; 3) 'Engineering judgment' and 'questionable' methods in the Fast Breeder analysis of the Society for Reactor Safety (GRS); 4) Assessment criteria of potential damage. (HP).

128

Radiation damage on amorphous metals. [Helium ion, neutron and gamma ray irradiation  

Energy Technology Data Exchange (ETDEWEB)

The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.

1982-04-01

129

Neural classifier construction using regularization, pruning and test error estimation.  

Science.gov (United States)

In this paper we propose a method for construction of feed-forward neural classifiers based on regularization and adaptive architectures. Using a penalized maximum likelihood scheme, we derive a modified form of the entropic error measure and an algebraic estimate of the test error. In conjunction with optimal brain damage pruning, a test error estimate is used to select the network architecture. The scheme is evaluated on four classification problems. PMID:12662736

1998-12-01

130

Diagnosis of early human myocardial ischemic damage with electron probe microanalysis  

Energy Technology Data Exchange (ETDEWEB)

We determined the Na/K x-ray intensity ratio in frozen sections of myocardial tissues obtained at autopsy from patients who died from various causes, using electron probe analysis. We have been able to distinguish between the ischemically injured and normal cells. The method is simple, fast, and dependable even when the duration of ischemia is only 30 minutes.

1983-03-01

131

A statistical pattern recognition paradigm for structural health monitoring  

Energy Technology Data Exchange (ETDEWEB)

The process of implementing a damage detection strategy for aerospace, civil and mechanical engineering infrastructure is referred to as structural health monitoring (SHM). Here damage is defined as changes to the material and/or geometric properties of these systems, including changes to the boundary conditions and system connectivity, which adversely affect the system's current or future performance. Our approach is to address the SHM problem in the context of a statistical pattern recognition paradigm (Farrar, Nix and Doebling, 2001). In this paradigm, the process can be broken down into four parts: (1) Operational Evaluation, (2) Data Acquisition, (3) Feature Extraction, and (4) Statistical Model Development for Feature Discrimination. When one attempts to apply this paradigm to data from 'real-world' structures, it quickly becomes apparent that data cleansing, normalization, fusion and ...

2004-01-01

132

Harm to the cell and harm to the individual  

International Nuclear Information System (INIS)

Exposures from most natural and artificial sources, with the exception of those from medical radiology, are received at average dose rates of only a few microsieverts a day. Such risks as may be caused by these exposures are most unlikely to be determined with precision directly by epidemiological studies of populations exposed at these low rates. They may, however, be reliably inferred from the observed risks of exposure to rather larger doses delivered at higher dose rates in the light of the increasing knowledge of the phenomena involved in the initial cellular damage, the extent to which such damage is incorrectly repaired, and the processes which intervene between the genetic or other harm to cells and the likelihood of its final expression in inherited abnormality, in cancer development, or in defective foetal or embryonic growth. Current studies are of great importance, therefore, in examining the circumstances in which coding sections ...

1983-04-11

133

Use of a point-of-care beta-hydroxybutyrate sensor for detection of ketonemia in dogs.  

Science.gov (United States)

The urine test strip is the most common test used to detect ketones in veterinary patients, but it can underestimate the degree of ketonuria and hence, ketonemia. Additionally, adequate urine samples for analysis may be difficult to obtain from dehydrated animals. The standard method used to detect and monitor ketonemia in human medicine is measurement of serum or whole blood beta-hydroxybutyrate (?HOB). A point-of-care (POC) analyzer has been validated for this purpose in humans. This study compared the accuracy of the POC device to an enzymatic reaction laboratory method for measurement of ?HOB in dogs. Although the POC sensor tended to overestimate ?HOB concentrations, there was good correlation (R(2) = 0.96) and good agreement between the 2 methods with a bias +/- precision of 0.0860 +/- 0.3410 mmol/L ?HOB. The POC ?HOB sensor can be useful for assessing ketonemia in dogs. ...

2010-09-01

134

Liquid chromatography with ultraviolet and dual parallel mass spectrometric detection for analysis of vitamin D in retail fortified orange juice  

British Library Electronic Table of Contents (United Kingdom)

Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...

2011-01-01

135

Hybrid Camera Surveillance System Using Robust Human Detection  

Science.gov (United States)

We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.

2007-01-01

136

Electrochemical noise in corrosion  

International Nuclear Information System (INIS)

By varying different variables (potential, chloride content, surface pretreatment etc.) it is possible to show the effect of increasingly harsher corrosion conditions on passive-layer stability. These changes will not be detected by conventional methods e.g. measurement of passive current density, until a very late stage. Electrochemical noise measurement will allow the action of inhibitors to be detected in a rapid and effective manner. High-alloy steels and titanium claddings subjected to pitting corrosion in chloride-containing media demonstrate how to use this method for problem solutions and to open up new practical applications. The effect of mechanical stresses (natural, tensile) on the corrosion system can be detected by electrochemical noise which opens up new methods for crack corrosion studying and monitoring. (orig./DG).

1993-10-07

137

Configurable Middleware-Level Intrusion Detection for Embedded Systems  

Energy Technology Data Exchange (ETDEWEB)

Embedded systems have become integral parts of a diverse range of systems from automobiles to critical infrastructure applications such as gas and electric power distribution. Unfortunately, research on computer security in general and intrusion detection in particular, has not kept pace. Furthermore, embedded systems, by their very nature, are application specific and therefore frameworks for developing application-specific intrusion detection systems for distributed embedded systems must be researched, designed, and implemented. In this paper, we present a configurable middleware-based intrusion detection framework. In particular, this paper presents a system model and a concrete implementation of a highly configurable intrusion detection framework that is integrated into MicroQoSCORBA, a highly configurable middleware framework developed for embedded systems. By exploiting the application-specific ...

2005-06-20

138

Sample preparation for nanoanalytical electron microscopy using the FIB lift-out method and low energy ion milling  

International Nuclear Information System (INIS)

Thinning specimens to electron transparency for electron microscopy analysis can be done by conventional (2-4 kV) argon ion milling or focused ion beam (FIB) lift-out techniques. Both these methods tend to leave 'mottling' visible on thin specimen areas, and this is believed to be surface damage caused by ion implantation and amorphisation. A low energy (250-500 V) Argon ion polish has been shown to greatly improve specimen quality for crystalline silicon samples. Here we investigate the preparation of technologically important materials for nanoanalysis using conventional and lift-out methods followed by a low energy polish in a GentleMill"T"M low energy ion mill. We use a low energy, low angle (6-8 deg.) ion beam to remove the surface damage from previous processing steps. We assess this method for the preparation of technologically important materials, such as steel, silicon and ...

2006-02-22

139

Surface effects of total coal-seam extraction by underground mining methods  

Energy Technology Data Exchange (ETDEWEB)

The paper gives a detailed overview of the history of subsidence engineering in South African collieries. Surface displacements resulting from total-seam extraction are discussed, and the important role of local geology is highlighted. It is shown that the differences in subsidence behaviour between South African and European collieries can be attributed to the presence of competent strata in the overburden of South African coal seams. Criteria are given for the prediction of the most important subsidence parameters, and a new model for the simulation of surface subsidence above total-extraction panels is introduced. The final section of the paper deals with the damage to surface structures caused by total-seam extraction. A brief summary of the most important undermining experiments in South African collieries is given, and it is concluded that local experiences of damage compare with those in Europe. 32 refs., 9 figs., 3 tabs.

1991-07-01

140

Microcantilever detector for explosives  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus for detecting the presence of explosives by analyzing a vapor sample from the suspect vicinity utilize at least one microcantilever. Explosive gas molecules which have been adsorbed onto the microcantilever are subsequently heated to cause combustion. Heat, along with momentum transfer from combustion, causes bending and a transient resonance response of the microcantilever which may be detected by a laser diode which is focused on the microcantilever and a photodetector which detects deflection of the reflected laser beam caused by heat-induced deflection and resonance response of the microcantilever. 2 figs.

1999-06-29

141

A high-sensitivity scintillation chamber for radon in gas  

Energy Technology Data Exchange (ETDEWEB)

A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))

1994-06-15

142

Improvement of detectability for circumferential crack of Steam Generator tube by eddy current and ultrasonic testing method  

International Nuclear Information System (INIS)

Steam Generator (SG) tubes in PWR plant are periodically inspected using eddy current testing (ECT) method. In Japan, bobbin coil type dual function probe is used for full length inspection, but the detectability for circumferential crack is very poor, and to improve detectability for circumferential crack and supplement regular ECT, various kinds of multi segment eddy current probes and multi transducer ultrasonic testing (UT) method have been developed. ECT probes are constructed of multiple surfaceriding special winding differential type coils and UT probe consists of 16 transducers which are spaced equally around the probe circumference for 360deg wall coverage. Both of those EC and UT probes are designed effective to detect circumferential crack. On the other hand, various kinds of laboratory induced circumferential cracks have been made and destroyed to prove the ...

1991-08-01

143

Effects of iodine deficiency on metabolism of metal ions in the rat brain by nuclear analytical techniques  

International Nuclear Information System (INIS)

Iodine deficiency disorders (IDD) are one of most common nutritional deficiencies in the world. The nuclear analytical methods (ENAA, SRXRF and XRF) were employed to study the effect of iodine deficiency on the metal ion changes during the stage of brain development, combined with biochemical methods. The results show that the distributions of iron, copper and zinc varied to different extent in different brain regions and subcellular fractions of the ID rat brains. These distributional changes of trace elements might be associated with the brain damage caused by the iodine deficiency. (author)

2006-09-01

144

Effective removal of Ga residue from focused ion beam using a plasma cleaner  

International Nuclear Information System (INIS)

Samples prepared using the focused ion beam (FIB) inevitably contain the surface damage induced by energetic Ga"+ ions. An effective method of removing the surface damage is demonstrated using a plasma cleaner, a device which is widely used to minimize the surface contamination in scanning transmission electron microscopy (STEM). Surface bombardment with low-energy Ar"+ ions was induced by biasing the sample immersed in the plasma source, so as to etch off the surface materials. The etch rates of SiO_2, measured with a bias voltage of 100-300 V, were found to vary linearly with both the time and bias and were able to be controlled from 1.4 to 9 nm/min. The removal of the Ga residue was confirmed using energy dispersive spectroscopy (EDS) after the plasma processing of the FIB-prepared sample. When the FIB-prepared sample was processed via plasma etching for 10 min with a bias of 150 V, the surface Ga ...

145

Chemical source identifications for natural resource injury/damage assessments and site assessments  

International Nuclear Information System (INIS)

Current regulations guiding technical aspects of natural resource damage assessments combine source, exposure pathway, resource injury, and monetary damage components. In order to associate any observed injury to the uncontrolled release of chemicals (e.g. oil spills, contaminated sediments, in-place toxics, etc.), it is important to link the chemical ''release'' to the injured resource. In complex environmental settings where multiple sources of similar chemicals are combined, multicomponent chemical methods must be used to link the release to the environmental distribution of chemicals. Three examples of the utility of multicomponent organic chemical analyses linked to comprehensive and representative sampling strategies will be discussed--the Shell Martinez Refinery oil spill, the Exxon Valdez oil spill, and a contaminated sediment assessment. These NRDA-based source identifications are based on use of polycyclic ...

1993-11-14

146

Laboratory Evaluation of an Electrochemical Noise System for Detection of Localized and General Corrosion of Natural Gas Transmission Pipelines  

Energy Technology Data Exchange (ETDEWEB)

Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of environments: (1) aqueous solutions typical of those found within gas ...

2003-03-16

147

Focused ion beam etching of nanometer-size GaN/AlGaN device structures and their optical characterization by micro-photoluminescence/Raman mapping  

Energy Technology Data Exchange (ETDEWEB)

The authors report on the nano-fabrication of GaN/AlGaN device structures using focused ion beam (FIB) etching, illustrated on a GaN/AlGaN heterostructure field effect transistor (HFET). Pillars as small as 20nm to 300nm in diameter were fabricated from the GaN/AlGaN HFET. Micro-photoluminescence and UV micro-Raman maps were recorded from the FIB-etched pattern to assess its material quality. Photoluminescence was detected from 300nm-size GaN/AlGaN HFET pillars, i.e., from the AlGaN as well as the GaN layers in the device structure, despite the induced etch damage. Properties of the GaN and the AlGaN layers in the FIB-etched areas were mapped using UV Micro-Raman spectroscopy. Damage introduced by FIB-etching was assessed. The fabricated nanometer-size GaN/AlGaN structures were found to be of good quality. The results demonstrate the potential of FIB-etching for the nano-fabrication of III-V nitride devices.

2000-07-01

148

Antioxidant and toxicity tests of roasted noni (Morinda citrifolia) leaf infusion  

British Library Electronic Table of Contents (United Kingdom)

Summary The antioxidant properties and toxicity profile of roasted noni (Morinda citrifolia L.) leaf infusion were evaluated. The 2,2-diphenylpicrylhydrazyl (DPPH) radical scavenging activity was greater than green tea infusion (81.6 +- 0.9% vs. 57.5 +- 1.8%, P < 0.001). The mean quercetin and kaempferol contents of roasted noni leaf infusion, as prepared by the consumer, were 0.24 +- 0.01 and 0.14 +- 0.01 mg mL-1, respectively. Tannic acid content was 10 +- 1 mg mL-1. The infusion was non-mutagenic in the reverse mutation test in Salmonella typhimurium and did not induce primary DNA damage in E. coli PQ37. Further, no significant primary DNA damage was induced by 5,15-dimethylmorindol, which was the only detectable anthraquinone in noni leaves. The infusion was not cytotoxic in the 24 h b...

2009-01-01

149

Study of cosmic ray nuclei detection by an image calorimeter  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.

1995-09-01

150

Radiation treatment of crude drugs. Development of suitable methods of detection. Strahlenbehandlung von Arzneidrogen. Entwicklung geeigneter Nachweismethoden  

Energy Technology Data Exchange (ETDEWEB)

It may be necessary to reduce microbiological contamination of crude drugs (medicinal plants or their parts like roots, leaves, flowers). This can be done by treating the drugs with ionizing radiation. Meethods for detection of such an irradiation were developed. It could be pointed out that measurements of luminescence, viscosity and electron spin resonance were suitable for specific drugs, but not for all drugs. (orig.).

1992-09-01

151

Evaluation of the Bactec MGIT 960 system in combination with the MGIT TBc identification test for detection of Mycobacterium tuberculosis complex in respiratory specimens.  

Science.gov (United States)

The sensitivity and specificity of the MGIT TBc identification (TBc ID) test for Mycobacterium tuberculosis complex (MTC) detection in positive Bactec MGIT cultures were 95.2% and 99.2%, respectively. When MTC-positive results obtained from two additional molecular methods were included, the sensitivity of the MGIT TBc ID test was 85.4%, while that of culture was 95.7%. PMID:21450949

2011-03-30

152

Detection of aortoarterial graft infections by leukocyte scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.

1983-09-01

153

A rapid and simple DNA extraction procedure to detect Salmonella spp. and Listeria monocytogenes from fresh produce using real-time PCR  

Science.gov (United States)

DNA isolation procedures significantly influence the outcome of PCR-based detection of human pathogens. Unlike clinical samples, DNA isolation from food samples such as fresh and fresh-cut produce has remained a formidable task and has hampered the sensitivity and accuracy of molecular methods. We...

154

Histopathological and immunohistochemical findings of 20 autopsy cases with 2009 H1N1 virus infection.  

Science.gov (United States)

Twenty autopsy cases with 2009 pandemic influenza A (2009 H1N1) virus infection, performed between August 2009 and February 2010, were histopathologically analyzed. Hematoxylin-eosin staining, immunohistochemistry for type A influenza nucleoprotein antigen, and real-time reverse transcription-PCR assay for viral RNA were performed on formalin-fixed and paraffin-embedded specimens. In addition, the D222G amino acid substitution in influenza virus hemagglutinin, which binds to specific cell receptors, was analyzed in formalin-fixed and paraffin-embedded trachea and lung sections by direct sequencing of PCR-amplified products. There were several histopathological patterns in the lung according to the most remarkable findings in each case: acute diffuse alveolar damage (DAD) with a hyaline membrane (four cases), organized DAD (one case), acute massive intra-alveolar edema with variable degrees of hemorrhage (three cases), neutrophilic bronchopneumonia (five cases) and ...

2011-08-26

155

Novel Method for Processing Respiratory Specimens for Detection of Mycobacteria by Using C18-Carboxypropylbetaine: Blinded Study  

UK PubMed Central (United Kingdom)

A novel method for processing respiratory specimens to improve culture and acid-fast staining of mycobacteria is introduced. This new method utilized N,N-dimethyl-N-(n-octadecyl)-N-(3-carboxypropyl)ammonium...Full Text Available

1998-07-01

156

Determination of lead in soil samples by "2"0"3Pb radioisotope dilution substoichiometric method  

International Nuclear Information System (INIS)

A procedure for the determination of lead in soil samples by "2"0"3Pb radioisotope dilution substoichiometric method is described. Japan NIES No.2 river clay standard sample and 83-40 Tibet soil standard sample were determined. The obtained values were in good agreement with reference values. The standard deviation of the method was less then 5%. Detection limit was about 0.1 #mu#g Pb.

157

The Blind NasoTracheal Aspiration Method Is Not a Useful Tool for Pathogen Detection of Pneumonia in Children  

UK PubMed Central (United Kingdom)

BackgroundAcute lower respiratory infection (ALRI) is a major cause of hospitalization for children in China, while the etiological diagnosis of ALRI remains a challenge. This study...Full Text Available

158

Species-specific Fungal DNA in Airborne Dust as Surrogate for Occupational Mycotoxin Exposure?  

UK PubMed Central (United Kingdom)

Possible health risks associated with occupational inhalation of mycotoxin-containing dust remain largely unknown, partly because methods for mycotoxin detection are not sensitive enough for the small...Full Text Available

159

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

160

ProMoST: A tool for calculating the pI and molecular mass of phosphorylated and modified proteins on 2 dimensional gels  

UK PubMed Central (United Kingdom)

Protein modifications such as phosphorylation are often studied by two-dimensional gel electrophoresis since the perturbation in the protein’s pI value is readily detected by this method....Full Text Available

2009-01-01

161

Power of grammatical evolution neural networks to detect gene-gene interactions in the presence of error  

UK PubMed Central (United Kingdom)

BackgroundWith the advent of increasingly efficient means to obtain genetic information, a great insurgence of data has resulted, leading to the need for methods for analyzing this...Full Text Available

162

LED Arrays as Cost Effective and Efficient Light Sources for Widefield Microscopy  

UK PubMed Central (United Kingdom)

New developments in fluorophores as well as in detection methods have fueled the rapid growth of optical imaging in the life sciences. Commercial widefield microscopes generally use arc lamps, excitation/emission...Full Text Available

163

Improved DNA Sequencing Accuracy and Detection of Heterozygous Alleles Using Manganese Citrate and Different Fluorescent Dye Terminators  

UK PubMed Central (United Kingdom)

The use of dideoxynucleotide triphosphates labeled with different fluorescent dyes (dye terminators) is the most versatile method for automated DNA sequencing. However, variation in peak heights reduces...Full Text Available

1999-06-01

164

Host-Encoded Reporters for the Detection and Purification of Multiple Enveloped Viruses  

UK PubMed Central (United Kingdom)

The identification of host cell factors for virus replication holds great promise for the development of new anti-viral therapies. Recently, high-throughput screening methods have emerged as...Full Text Available

2010-08-01

165

High-density multiplex detection of nucleic acid sequences: oligonucleotide ligation assay and sequence-coded separation.  

UK PubMed Central (United Kingdom)

We describe a non-isotopic, semi-automated method for large-scale multiplex analysis of nucleic acid sequences, using the cystic fibrosis transmembrane regulator (CFTR) gene as an example. Products...Full Text Available

1994-10-25

166

High-Throughput Screen for Poly-3-Hydroxybutyrate in Escherichia coli and Synechocystis sp. Strain PCC6803  

UK PubMed Central (United Kingdom)

A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available

2006-05-01

167

Gene expression analysis of interferon ? in laser capture microdissected cervical epithelium  

UK PubMed Central (United Kingdom)

Optimal sample handling techniques for tissue preparation and storage, RNA extraction and quantification, and target gene detection are crucial for reliable gene expression analysis. Methods...Full Text Available

2008-10-01

168

Gear fault detection using customized multiwavelet lifting schemes  

Science.gov (United States)

Fault symptoms of running gearboxes must be detected as early as possible to avoid serious accidents. Diverse advanced methods are developed for this challenging task. However, for multiwavelet transforms, the fixed basis functions independent of the input dynamic response signals will possibly reduce the accuracy of fault diagnosis. Meanwhile, for multiwavelet denoising technique, the universal threshold denoising tends to overkill important but weak features in gear fault diagnosis. To overcome the shortcoming, a novel method incorporating customized (i.e., signal-based) multiwavelet lifting schemes with sliding window denoising is proposed in this paper. On the basis of Hermite spline interpolation, various vector prediction and update operators with the desirable properties of biorthogonality, symmetry, short support and vanishing moments are constructed. The customized lifting-based multiwavelets for feature matching ...

2010-07-01

169

Failure to detect circulating DNA--anti-DNA complexes by four radioimmunological methods in patients with systemic lupus erythematosus.  

UK PubMed Central (United Kingdom)

The presence of DNA-anti-DNA complexes in sera from patients with systemic lupus erythematosus (SLE) was investigated by two new radioimmunoassays (RIA) developed for this purpose and by measuring the...Full Text Available

1977-12-01

170

Effective audit trails--a taxonomy for determination of information requirements.  

UK PubMed Central (United Kingdom)

Current methods of detecting confidentiality breaches in electronic medical record systems are inadequate, partially due to the lack of necessary information at the point of audit trail analysis. In...Full Text Available

1999-01-01

171

Detection of Unculturable Bacteria in Periodontal Health and Disease by PCR  

UK PubMed Central (United Kingdom)

Recently developed molecular methods have made it possible to characterize mixed microflora in their entirety, including the substantial numbers of bacteria which do not grow on artificial culture media....Full Text Available

1999-05-01

172

Detection of Chlamydia trachomatis in genital swabs: comparison of commercial and in house amplification methods with culture  

UK PubMed Central (United Kingdom)

AIMS: To evaluate the sensitivity of the Roche Cobas, Roche Amplicor plate kit, ligase chain reaction (LCR), and an in house polymerase chain reaction (PCR) by titration of purified elementary bodies...Full Text Available

1998-08-01

173

Detection of Atopobium vaginae in Postmenopausal Women by Cultivation-Independent Methods Warrants Further Investigation  

UK PubMed Central (United Kingdom)

We sequenced 16S rRNA genes from the vaginal swab contents of a postmenopausal woman with asymptomatic bacterial vaginosis (BV). Sequences from Atopobium vaginae were the most commonly...Full Text Available

2004-04-01

174

Comparative experimental study of dual energy subtraction and conventional digital radiography on chest  

International Nuclear Information System (INIS)

Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR ...

2005-06-01

175

Clinical significance of Fas and FasL protein expression in gastric carcinoma and local lymph node tissues  

UK PubMed Central (United Kingdom)

AIM: To investigate the relation of Fas and Fas ligand (FasL) protein expression with carcinogenesis and metastasis of gastric carcinoma.METHODS: Immunohistochemistry was used to detect Fas and...Full Text Available

2010-03-14

176

Analysis of Quantitative Interactions between Two Species of Arbuscular Mycorrhizal Fungi, Glomus mosseae and G. intraradices, by Real-Time PCR  

UK PubMed Central (United Kingdom)

Arbuscular mycorrhizal fungi (AMF) are obligate biotrophs, known to play an important role in ecological processes. Conventional light microscopy is the most common method used to detect their presence...Full Text Available

2006-06-01

177

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

178

A convenient and sensitive allergy test: IgE crosslinking-induced luciferase expression in cultured mast cells  

UK PubMed Central (United Kingdom)

BackgroundFor the detection of allergen-specific IgE in sera, solid-phase IgE-binding assays like the CAP test are commonly used. Although such immunochemical methods are very sensitive,...Full Text Available

2010-10-01

179

A Simple Colorimetric Assay for Specific Detection of Glutathione-S Transferase Activity Associated with DDT Resistance in Mosquitoes  

UK PubMed Central (United Kingdom)

BackgroundInsecticide-based methods represent the most effective means of blocking the transmission of vector borne diseases. However, insecticide resistance poses a serious threat...Full Text Available

180

A Hybrid Capillary-Microfluidic Device for the Separation, Lysis, and Electrochemical Detection of Vesicles  

UK PubMed Central (United Kingdom)

The primary method for neuronal communication involves the extracellular release of small molecules that are packaged in secretory vesicles. We have developed a platform to separate, lyse, and...Full Text Available

2009-03-15

181

Analysis of o-tyrosine as a method for the identification of irradiated chicken and the comparison with other methods (analysis of volatiles and ESR-spectroscopy)  

Energy Technology Data Exchange (ETDEWEB)

With the mentioned method to analyse O-tyrosine with HPLC/fluorescence-detection, the irradiation of chicken meat can be determined in a simple and fast way. The formation of o-tyrosine is proportional to the applied dose but because it is also depending on the applied dose rate and the temperature during the irradiation, it is not possible to control the irradiation dose. Since unirradiated chicken can contain little amounts of o-tyrosine and to confirm some results, a second method is needed. Together with one of the other mentioned methods (analysis of the volatiles or esr-spectroscopy) it is possible to recognize irradiated chicken with a high security. (author).

1990-01-01

182

New remote sensing techniques for the detection and quantification of earth surface CO2 degassing  

British Library Electronic Table of Contents (United Kingdom)

Earth degassing specifically of carbon dioxide CO2 is of increasing interest with respect to the global carbon budget, related climate effects, earthquake and volcano eruption mechanisms, as well as plant physiological reactions in gas-rich environments. Investigations in all of these disciplines require the detection of surface CO2 degassing structures and quantification of their emissions. We introduce minimal thermal change detection based on infrared imaging as a new remote sensing tool for the detection of earth surface thermal anomalies suiting among others to discover earth degassing locations of any origin. The method allows for seamless areal search and monitoring of degassing structures in any terrain. As proof of concept infrared imaging measurements were performed at the Bossol...

2008-01-01

183

Idaho National Laboratory Supervisory Control and Data Acquisition Intrusion Detection System (SCADA IDS)  

Energy Technology Data Exchange (ETDEWEB)

Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.

2008-05-01

184

Comparison of media and methods for detecting and enumerating Listeria monocytogenes in refrigerated cabbage.  

Science.gov (United States)

Direct plating, selective enrichment, and cold enrichment followed by secondary selective enrichment procedures were compared for detecting and enumerating Listeria monocytogenes in chopped cabbage stored at 5 degrees C for up to 64 days. Addition of Fe3+ to solid media enhanced detection of the organism. Cold enrichment (5 degrees C) in nutrient broth and brain heart infusion broth followed by secondary enrichment (48 h, 30 degrees C) in Trypticase soy-yeast extract-antibiotic broth and thiocyanate-nalidixic acid broth and plating on selective agar media (Doyle and Schoeni selective enrichment agar [minus acriflavin hydrochloride, supplemented with 5 micrograms of Fe3+/ml] and McBride Listeria agar) resulted in the detection of highest populations. PMID:3111369

1987-05-01

185

Comparative studies on titanium and tantalum oxides thin film structures for laser mirrors, deposited by ion assisted gun  

International Nuclear Information System (INIS)

For obtaining radiation less damagable laser mirrors, a preliminary optimization of film fabrication suitable for the analysis of laser damage mechanism has been done as the first step. Here, the optimization requires not only the stable fabrication process but also the ideal film structure i.e., the amorphous and smooth film structure simultaneously, eliminating latently unwanted secondary effects such as light scattering during laser damage test. For this purpose, we adopted the ion assisted deposition (IAD) method and modified the deposition conditions for titanium and tantalum oxide films, both of which compose typical high index layers, and where SiO_2 layers are also chosen as low index layers because of their amorphous and smooth nature, in alternative multilayer laser mirrors. Surface and cross sectional film structures and film crystallinity are compared and characterized, using a high ...

1996-10-07

186

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic method was developed that ...

1995-08-01

187

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

188

Impact of ocean pollution  

Energy Technology Data Exchange (ETDEWEB)

Man's wastes are polluting the oceans from various sources and delivered by various routes. The result has been the loss of habitat and the irreversible altering of marine ecosystems. Development in the coastal zones and offshore activities that disrupt biologically sensitive areas have led to international negotiations to regulate these impacts and develop a law of the sea. Basic to international cooperation, however, is the need to develop answers to questions about the ecological consequences of development programs and the carrying capacity of the oceans. Current information does not demonstrate long-term global impacts, making it difficult to detect and predict incremental changes and causal relationships. Society needs to determine how much environmental damage it will accept and then to develop appropriate technology, such as biomonitoring. Society also needs to reexamine its positions on technology-based regulatory controls to ...

1981-03-01

189

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

190

Effects of ozone on gene expression and lipid peroxidation in adults and larvae of the red flour beetle (Tribolium castaneum)  

British Library Electronic Table of Contents (United Kingdom)

Ozone has in recent years been increasingly investigated for its potential use in the control of insect pests of stored cereals. Ozone is a powerful oxidizing agent that can react directly, or via production of reactive oxygen species, with proteins, DNA and double bonds of polyunsaturated fatty acids (PUFA). The aim of the present study was to investigate the mode of action in ozone toxicity using the red flour beetle, Tribolium castaneum (Herbst), as a relevant model. Transcription of focal genes thought to be involved in protection against ozone, and repair of cellular damage caused by ozone exposure, was studied together with the composition of storage lipid fatty acids and membrane phospholipid fatty acids in order to detect lipid peroxidation. Contrary to expectations, transcription ...

2011-01-01

191

Early-stage focal nodular hyperplasia: US/CT/MR features correlated with histology  

Energy Technology Data Exchange (ETDEWEB)

Two cases of focal nodular hyperplasia (FNH), in which ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MR) studies detected an atypical hemorrhagic pattern associated with an intrahepatic arterio venous malformation (AVM) around the growths, are presented. In both cases, histology demonstrated a very early regenerative stage and necrotic-hemorrhagic areas within the lesions. In these cases, the analysis of radiological findings, surgical specimens and histology seemed to confirm the pathogenetic hypothesis suggested by Wanless: in normal liver parenchyma, a ``blood steal`` phenomenon due to congenital or acquired intrahepatic AVM could cause ischemic damage, appearing as a hemorrhagic necrotic area, the extent of which depends on the degree of residual portal supply. (orig.)

1994-02-01

195

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI ...

196

Hierarchical Kohonenen net for anomaly detection in network security.  

Science.gov (United States)

A novel multilevel hierarchical Kohonen Net (K-Map) for an intrusion detection system is presented. Each level of the hierarchical map is modeled as a simple winner-take-all K-Map. One significant advantage of this multilevel hierarchical K-Map is its computational efficiency. Unlike other statistical anomaly detection methods such as nearest neighbor approach, K-means clustering or probabilistic analysis that employ distance computation in the feature space to identify the outliers, our approach does not involve costly point-to-point computation in organizing the data into clusters. Another advantage is the reduced network size. We use the classification capability of the K-Map on selected dimensions of data set in detecting anomalies. Randomly selected subsets that contain both attacks and normal records from the KDD Cup 1999 benchmark data are used to train the hierarchical net. We use a confidence ...

2005-04-01

197

Sorbent extraction and high performance liquid chromatography (HPLC) of homidium bromide and isometamidium chloride in bovine plasma  

International Nuclear Information System (INIS)

Homidium bromide and isometamidium chloride are used extensively in the treatment of bovine trypanosomiasis in Africa, but no specific and sensitive method to detect the drug in plasma has been published yet. Comparing the methods of other investigators it was found that they could not overcome the protein binding of these drugs which reduced the available and determined drug to 10% of the real concentrations. These techniques overcome the protein binding by enzyme digestion and an alteration of the pH before adding the sample directly on clean-up columns. Drug recover rates above 80% were obtained. For the detection, the HPLC was employed using a C18 reversed phase analytical column and UV detection, determining both drugs as intact molecules. (author).

1992-01-01

198

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

199

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach ...

1986-04-01

200

Identification of oxidation states of ultra-trace elements by radiation detection  

International Nuclear Information System (INIS)

The determination of the oxidation state of ultra-trace elements in the environment, especially in the case of actinides, is of importance in many ways. Speciation techniques using radiation may comprise methods based on the detection of the nuclear and atomic radiations emitted in radioactive decay or methods using external sources of excitation. In the former instance, information can be obtained from the energy and intensity of radiation, but at present the partition method is still the most commonly used, although its reliability is questionable. Excitation with intense laser beams, as is currently being used for trace element analysis in photoacoustic and thermal lensing spectroscopic techniques, could conceivably be applied under suitable conditions to ultra-trace elements with a sensitivity approaching that of the radiochemical methods.

1989-11-01

201

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be ...

2009-07-23

202

Fault detection by Turam TEM survey. Numerical model studies and a case history; TEM ho Turam sokutei haichi ni yoru danso kenshutsu no kokoromi. Model keisan to jisshirei  

Energy Technology Data Exchange (ETDEWEB)

With an objective to detect faults estimated to exist along the Shigesumi valley in the Kamioka mine, discussions were given by using electromagnetic survey, which uses the Turam measurement arrangement based on the TEM method, and three-dimensional model calculations. The Turam measurement arrangement, which installs transmission loop fixedly, is used to identify nature and distribution of electrically conductive objects upon noticing abnormal portions in magnetic fields in the measurement data. In the model calculation, the plate model calculation method and the FDTD method were used, and so was the calculation code TEM3DL. The result revealed that strong topographical influence is seen from steep V-shaped valley existing along the traverse line in the measurement data, but an abnormal resistivity band accompanying remarkable distortion in the curve was detected. According to the ...

1997-05-27

203

Self-lubricating performance and durability of ball bearings for the LE-7 liquid oxygen rocket-turbopump  

Energy Technology Data Exchange (ETDEWEB)

The durability of ball bearings, 32-mm- and 45-mm-bore, with a retainer or glass cloth-polytetrafluoroethylene (PTFE) laminate was tested under a high radial load at a speed of 20,000 rpm in LOX or LN2. The retainers were characterized as good self-lubricators because the abrasive glass-cloth fiber tips exposed on the retainer were chemicaly etched away with hydrofluoric acid (HF). During testing, the bearing-cartridge-acceleration was monitored to detect bearing damage. Testing in LOX for about 2.2 hr showed that excellent lubricating conditions were obtained for all bearings. Testing in LN2 for about 5.1 hr detected that the fatigue life of the bearing was about the same as the calculated B10 fatigue life. The HF chemical treatment resulted in a reacted fluoride-oxide material which remained in the etched part of the glass fiber. Several chemical products, particularly MgO, CaO, and CaCO3, enhanced adhesion of PTFE ...

1993-09-01

204

Lipiodol-CT in the detection of tumor persistence in hepatocellular carcinoma treated with percutaneous ethanol injection  

Energy Technology Data Exchange (ETDEWEB)

Our purpose was to investigate the usefulness of Lipiodol-CT for detection of residual viable neoplastic tissue in hepatocellular carcinoma (HCC) lesions treated by means of percutaneous ethanol injection (PEI). An emulsion of 5 to 20 ml iodized oil and 50 to 70 mg doxorubicin hydrochloride was intraarterially injected in 18 patients with 25 HCC lesions treated by means of PEI one to 24 months before. At CT performed 3 to 5 weeks after injection, retention of Lipiodol was observed in 9 of 13 tumors that still contained viable neoplastic tissue and in 2 of 12 tumors proven to have undergone complete necrosis after PEI. The sensitivity and specificity of Lipiodol-CT were 69.2% and 83.3%, respectively. Thus, Lipiodol-CT seems to have limited diagnostic value after PEI, probably as a consequence of the alcohol-induced vascular damage, accounting for both false-negative and false-positive results. (orig.).

1994-07-01

205

Hydrogen-plasticity interactions in pearlitic steel: a fractographic and numerical study  

Energy Technology Data Exchange (ETDEWEB)

A fractographic and numerical approach is presented to analyze hydrogen-plasticity interactions in pearlitic steel and to elucidate the main hydrogen transport mechanism in this material under triaxial stress states produced by notches. Fractographic analysis showed that the microdamage produced by the hydrogen was clearly detectable by scanning electron microscopy (SEM), through a specific microscopic topography associated with hydrogen effects (tearing topography surface or TTS). Numerical computations obtained by using an elastic-plastic finite element program gave the progressive spreading of the plastic zone, closely associated with the movement of dislocations. In the majority of cases, the plastic zone (PZ) clearly exceeds the hydrogen affected region (TTS) and has no relation with it. In some tests, however, the hydrogen-induced micro-damage surpasses the only region in which there is dislocation movement, and in this case the net ...

1996-11-30

206

Demonstration of mobile accelerator neutron radiography for in situ detection of moisture and corrosion in aircraft structures  

Energy Technology Data Exchange (ETDEWEB)

A demonstration of the first mobile 'on-off' neutron radiography system, developed by Vought Corporation Advanced Technology Center, has been conducted at McClellan Air Force Base. On-site neutron radiography operations with the engineering model were carried out to demonstrate the potential of such a system for in situ detection of hidden moisture and corrosion in aircraft structures, and to assess the performance of the unique hardware system in a depot environment. Inspections were performed on F-111 and F-106 aircraft, and several structures removed from T-39 and A-10 aircraft were also inspected. The effectiveness of the new N-ray system for imaging moisture and corrosion was confirmed after subsequent removal of skins from some of the F-111 structures. Excellent correlation of radiographic images with actual moisture and corrosion damage was attained. Both film and real time/near real time neutron imaging were ...

1983-01-01

207

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular ...

1987-01-01

208

Unidirectional growth, linear and nonlinear optical, dielectric and mechanical properties of organic adduct of L-tartaric acid nicotinamide  

International Nuclear Information System (INIS)

An attempt has been made to grow L-tartaric acid nicotinamide (LTN); a complex of tartaric acid, by employing a modified unidirectional method. The crystalline structure and quality are investigated by single crystal XRD and rocking curve studies. The linear and nonlinear optical properties are studied by UV-vis-NIR spectral analysis, SHG test, phase matching and laser induced damage threshold measurement. For comparison, parallel growth of the crystal was carried out by conventional method and the properties of the LTN samples grown by the conventional and unidirectional methods are investigated. The mechanical, photoconductivity and dielectric behavior of LTN crystals are also investigated.

2011-03-15

209

Projective goals - concepts and pragmatic aspects based on the terminology and methodology of safety science  

International Nuclear Information System (INIS)

Protective goals set the line of orientation of tasks and activities in the field of accident prevention. They have to be based on safety-science methods in order to develop from the conceptual idea to the practically feasible solution, while using the scientific methods to take into account the facts and the capabilities of a situation and, proceeding from them, finding an efficient and rational, optimal pragmatic approach by way of various strategies or tactics. In this process, the activities of defining, informing, thinking and developing need the proper terminology. Safety is absence of danger, protection is limitation of danger and prevention of damage. So it is protection what is needed with danger being given, and risks have to be minimized. Riskology is a novel method of safety science, combining risk analysis and risk control into a systematic concept which is practice-oriented. Applying this ...

210

Shielded and unshielded geometries in the search for orphan sources  

Energy Technology Data Exchange (ETDEWEB)

A car-borne NaI(Tl) spectrometric system was used together with a {sup 137}Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-15

211

Shielded and unshielded geometries in the search for orphan sources  

International Nuclear Information System (INIS)

A car-borne NaI(Tl) spectrometric system was used together with a "1"3"7Cs source to obtain realistic data in the search for unshielded and semi-shielded orphan sources. The potassium-stripped counts (PSC) method was used to estimate the influence by the shielding on the detection ability. A reduction of about 5% in the critical distance was obtained for the semi-shielded source. A curve fitting method was also developed and evaluated. Results from the curve fitting method showed inferior ability to find the source compared to the PSC method. However, it can be a useful complementary tool, for characterisation of the source shielding, and estimation of the distance from the road.

2006-05-01

212

Nondestructive testing of metal coating thickness and control of chemical composition using radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

The principle is described of a method using low-activity emitters as the primary radiation source for analysis. The selection of the radiation source and the detection methods including the assessment of the applicability of various radiation detectors are discussed. The benefits and the constraints of the method are considered. Practical examples are presented showing the application possibilities of the method for testing the thickness of bearing layers, piston ring coats, lead layers, etc. The possibility is shown of applying the rapid test for the composition of tungsten and chromium alloyed metal materials in testing complex systems. (J.K.).

1974-12-03

213

A Two-Step Etching Method to Fabricate Nanopores in Silicon  

CERN Document Server

A cost effectively method to fabricate nanopores in silicon by only using the conventional wet-etching technique is developed in this research. The main concept of the proposed method is a two-step etching process, including a premier double-sided wet etching and a succeeding track-etching. A special fixture is designed to hold the pre-etched silicon wafer inside it such that the track-etching can be effectively carried out. An electrochemical system is employed to detect and record the ion diffusion current once the pre-etched cavities are etched into a through nanopore. Experimental results indicate that the proposed method can cost effectively fabricate nanopores in silicon.

2008-01-01

214

QTL mapping in outbred half-sib families using Bayesian model selection.  

Science.gov (United States)

In this article, we propose a model selection method, the Bayesian composite model space approach, to map quantitative trait loci (QTL) in a half-sib population for continuous and binary traits. In our method, the identity-by-descent-based variance component model is used. To demonstrate the performance of this model, the method was applied to map QTL underlying production traits on BTA6 in a Chinese half-sib dairy cattle population. A total of four QTLs were detected, whereas only one QTL was identified using the traditional least square (LS) method. We also conducted two simulation experiments to validate the efficiency of our method. The results suggest that the proposed method based on a multiple-QTL model is efficient in mapping multiple QTL for an outbred half-sib population and is more powerful than the LS method ...

2011-04-13

215

User's manual of SECOM2: a computer code for seismic system reliability analysis  

International Nuclear Information System (INIS)

This report is the user's manual of seismic system reliability analysis code SECOM2 (Seismic Core Melt Frequency Evaluation Code Ver.2) developed at the Japan Atomic Energy Research Institute for systems reliability analysis, which is one of the tasks of seismic probabilistic safety assessment (PSA) of nuclear power plants (NPPs). The SECOM2 code has many functions such as: Calculation of component failure probabilities based on the response factor method, Extraction of minimal cut sets (MCSs), Calculation of conditional system failure probabilities for given seismic motion levels at the site of an NPP, Calculation of accident sequence frequencies and the core damage frequency (CDF) with use of the seismic hazard curve, Importance analysis using various indicators, Uncertainty analysis, Calculation of the CDF taking into account the effect of the correlations of responses and capacities of components, and Efficient sensitivity analysis by ...

216

Present status and problems of high temperature coatings by thermal spraying system. Yosha ho ni yoru koon coatings by thermal spraying system  

Energy Technology Data Exchange (ETDEWEB)

This report outlines on the corrosive damage which is inherent to a high temperature environment and introduces on thermal spraying system taking an example of a gas turbine. The recent coatings by thermal spraying for high temperature environment are positively used in such applications as a hearth roll for continuous annealing, a roll for hot dipped steelplate, a solid electrolyte for fuel cell, boilers and rockets. The coating formed will be positively used because of a convenient thermal spraying and availability of various sprayable materials. This report describes the following items. Corrosive damage under the high temperature environment. Types of high temperature corrosive coating by a thermal spraying and utilization thereof. Outline of MCrAlX alloy, and merits thereof. Coating to a turbine wing by rduced pressure plasma thermal spraying. In general, it is urgently needed to establish the methods of ...

1990-10-30

217

Elephant's foot phenomenon in liquid storage tanks  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a method for analyzing the seismic response of a flat bottomed cylindrical liquid storage tank to vertical earthquake excitation. Here, vertical earthquake acceleration is considered to correspond to an increase in the density of a stored liquid. Taking into account the vertical and horizontal earthquake loads, hydrostatic pressure, and considering restrictive moment and shear forces at shell-bottom welded joint, the author has calculated circumferential and longitudinal stresses. These are combined to more accurately approximate the stresses at the base shell course. The calculated result closely conforms to the actual damage, termed ''elephant's foot,'' observed in the fuel storage tanks damaged in the Tangshan earthquake. This result shows that the ''elephant's foot'' phenomenon is not caused by buckling of the ...

1983-01-01

218

[Development of efficient DNA isolation procedures for Cryptosporidium and Trichinella PCR detection in fecal samples].  

Science.gov (United States)

PCR detection of genetic material of the parasites present in faeces may be an alternative for microscopic and serological tests routinely used for diagnosing parasitic enteral infections. However, small amount of target DNA combined with low efficiency of total DNA extraction, and presence of PCR inhibitors in the samples to be amplified, may cause false negative detection results. The aim of this work was to evaluate the impact of DNA isolation procedure used on the amplification of DNA fragments from the genomes of protozoan Cryptosporidium parvum and the nematode Trichinella spiralis. Two methods based on different principles of biological material lysis were evaluated; NucliSENS miniMAG employing simultaneously applied chemical lysis and mechanical disruption or mechanical disruption followed by enzymatic lysis in case of QIAamp DNA Stool Mini Kit. Both of the analyzed systems for nucleic acids purification allowed ...

2009-01-01

219

Robustness of timber structures in seismic areas  

British Library Electronic Table of Contents (United Kingdom)

Major similarities between robustness assessment and seismic design exist, and significant information can be brought from seismic design to robustness design. As will be discussed, although some methods and limitations considered in seismic design can improve robustness, the capacity of the structure to sustain limited damage without disproportionate effects is significantly more complex. In fact, seismic design can either improve or reduce the resistance of structures to unforeseeable events, depending on the structural type, triggering event, structural material, among others. Based on a case study, the influence of redundancy and ductility on the seismic behavior and robustness of a long-span timber structure is assessed.

2011-01-01

220

Risk-orientated analysis of the SNR 300. Technical report 1. Risk assessment of the fast breeder reactor. Risikoorientierte Analyse zum SNR 300. Fachbericht 1. Risikobewertung des Schnellen Brueters  

Energy Technology Data Exchange (ETDEWEB)

The study required by the West German Ministry of Research and Technology (RS 605) for the Committee on 'Future Nuclear Energy Policy' of the 9th German Parliament is concerned with the following main points: 1) Assessment of technical risks from the social aspect; 2) Discussion of terms and quantification of risks; 3) 'Engineering judgment' and 'questionable' methods in the Fast Breeder analysis of the Society for Reactor Safety (GRS); 4) Assessment criteria of potential damage.

1983-09-01

221

Radiation-stimulated diffusion of aerosols  

Energy Technology Data Exchange (ETDEWEB)

The diffusion coefficient of particles in radioactive gases has been calculated with account of random wandering of aerosols (occurrence of local fields affecting the particles; recoils accompanying radiation emitted by particles, etc.). To determine the diffusion coefficient, the method of Fokker-Planck equation derivation was used. A formula is presented for calculating the radiation-stimulated diffusion coefficient. A linear growth of the diffusion coefficient with radioactivity is noted according to the formula, the diffusion coefficient is mainly determined by the field in the radiation damage region. The aerosol radioactivity may result in a more rapid deposition of aerosols in the pipelines and aerosol purification systems. The diffusion rate grows not only in the presence of intrinsic radioactivity but in case of external radiation exposure as well.

1984-04-01

222

Probabilistic safety assessment of station blackout accident and 5th emergency diesel in Daya Bay NPP  

International Nuclear Information System (INIS)

In this paper, probabilistic safety assessment (PSA) of the station blackout (SBO) and 5th emergency diesel in Daya Bay NPP has been carried out, the calculation method of non-recover factors of power supplies is given, and sensitivity analysis on the connection duration of 5th emergency diesel has been executed. It is concluded that the core damage frequency (CDF) induced by SBO is relatively large, the addition of 5th emergency diesel is very helpful for the CDF reduction, and the connection duration of this diesel has great effect on the CDF reduction

2004-08-01

223

Leachability of neutron irradiated fly ash  

Science.gov (United States)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-11-01

224

Leachability of neutron irradiated fly ash  

International Nuclear Information System (INIS)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-01-01

225

Application of fracture mechanics to cementitious composites  

Energy Technology Data Exchange (ETDEWEB)

This work contains 27 chapters which cover recent advances in fracture mechanics applied to cement-based composites: concrete, reinforced concrete, and fiber reinforced concrete. The book, based on a NATO Advanced Study Institute, is a comprehensive survey of treating nonlinearity associated with crack growth in brittle materials such as cement composites, rocks and ice. The book is divided into 8 major themes: advances in nonlinear fracture mechanics; fracture processes; numerical modelling of fracture; experimental methods of determining fracture parameters; damage and continuum modelling; strain-rate and dynamic effects of crack propagation; stress-corrosion, time and temperature effects on fracture; and implications for concrete structures.

1985-01-01

226

Particle Detection with drift Chambers  

CERN Document Server

Particle Detection with drift Chambers

2008-01-01

227

Laser flash effects on chromatic discrimination in monkeys. Final report, April 1986-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Detecting a camouflaged target in a visually noisy background depends on the ability of the observer to discriminate the target from the surrounding terrain. Visible laser irradiation at less than damage levels can act as a masking source by compromising or reducing the observer's ability to resolve differences in the visual scene. Previous research has examined this concept by investigating laser flash effects on: acuity (size discrimination); tracking (motion discrimination); visual sensitivity (color); and contrast sensitivity functions (luminance contrast). In all cases, flashes from continuous-wave (CW) sources have proven more effective visually than pulsed (Q-switched) sources, when compared on peak-energy criteria (i.e., MPE), even though Q-switched lasers induce damage at lower energy doses. Additionally, the inherent safety of ultra-short laser pulses has been questioned. Past animal research has shown ...

1987-10-01

228

Statistical characterization of pitting corrosion process and life prediction  

International Nuclear Information System (INIS)

In order to prevent corrosion failures of machines and structures, it is desirable to know in advance when the corrosion damage will take place, and appropriate measures are needed to mitigate the damage. The corrosion predictions are needed both at development as well as operational stage of machines and structures. There are several forms of corrosion process through which varying degrees of damage can occur. Under certain conditions these corrosion processes at alone and in other set of conditions, several of these processes may occur simultaneously. For a certain type of machine elements and structures, such as gears, bearing, tubes, pipelines, containers, storage tanks etc., are particularly prone to pitting corrosion which is an insidious form of corrosion. The corrosion predictions are usually based on experimental results obtained from test coupons and/or field experiences of similar machines or parts of a ...

229

Optimal design of perforating completion for gas well  

Energy Technology Data Exchange (ETDEWEB)

The productivity characteristics of perforated gas well are investigated for the first time under real conditions considering drilling damage, perforation compacted zone and anisotropy in this paper. A non-linear finite element model for non-Darcy flow in perforated gas reservoir is built to consider the effects of twelve factors on productivity ratio (PR) of perforated gas well. The nomographs for two cases are presented in this paper. Compared with previous works, the following results are found: (1) the effects of drilling damage and perforation diameter on PR of gas well are more remarkable than that in oil well; (2) any perforation phase may be the best or the worst as to perforating gas well, which depends on anisotropy, drawdown and that whether or not perforations are beyond drilling damage zone; (3) the increase in perforation length hardly improve PR of gas well when perforations have been beyond drilling ...

1995-10-01

230

Detection of basepair substitution mutation at a frequency of 1 x 10(-7) by combining two genotypic selection methods, MutEx enrichment and allele-specific competitive blocker PCR.  

Science.gov (United States)

The detection of rare mutations has many important applications, including risk assessment of drugs and chemicals, measuring environmental exposures to genotoxins, and cancer cell detection. A sensitive genotypic selection method has been developed that combines two different mutant allele selection techniques, MutEx enrichment and allele-specific competitive blocker PCR (ACB-PCR). This method was developed and evaluated for the detection of a CAA --> AAA mutation at codon 61 of the mouse H-ras gene. The MutEx enrichment is based on MutS binding to a mismatched basepair in heteroduplex DNA. The bound MutS protects the mutant allele from degradation during subsequent exonuclease treatment. ACB-PCR preferentially amplifies a mutant allele in a PCR reaction using a primer that has more mismatches to the wild-type allele than the mutant allele. By combining these two approaches, the ...

1998-01-01

231

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

232

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

233

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

234

Instantaneous energy density as a feature for gear fault detection  

Science.gov (United States)

In this work, energy-based features for gear fault diagnosis and prediction are proposed. The instantaneous energy density is shown to obtain high values when defected teeth are engaged. Three methods are compared in terms of sensitivity, reliability and computation effectiveness. The Wigner Ville distribution is contrasted to the wavelet transform and the newly proposed empirical mode decomposition scheme. It is shown that all three methods are capable of a reliable prediction. An empirical law, which relates the energy content to the crack magnitude is established.

2006-07-01

235

Detection of acute myocardial infarction in spontaneously hypertensive rats by /sup 99m/Tc-Pyrrolidino methyl tetracycline  

Energy Technology Data Exchange (ETDEWEB)

The myocardial infarct induced by isoproterenol in spontaneously hypertensive rats accumulates higher activities of /sup 99/sup(m)Tc-PM tetracycline compared with the cardiac infarct in normotensive rats caused by the same method. The isoproterenol model of the myocardial necrosis was induced in intact rats without opening the thorax and is a convenient method for experimental radioisotope studies.

1983-01-01

236

Computer tomography used in tumour diagnosis in children  

Energy Technology Data Exchange (ETDEWEB)

Computer tomography used in the diagnosis of tumours is described in the light of particularly great diagnostic difficulties in children. Computer tomography was applied in 12 cases. A high diagnostic value of this method was demonstrated, which makes possible a more accurate diagnosis of the position of the tumour, its size, and expanding tendency. The possibility of estimating healthy tissues and organs, and those with pathological changes on the basis of differences in their density with a detection threshold at 0.5% density difference facilitates not infrequently preoperative diagnosis raising the value of the method.

1981-01-01

237

CT colonography. Virtual coloscopy; CT-Kolonographie. Virtuelle Koloskopie  

Energy Technology Data Exchange (ETDEWEB)

The CT colonography or virtual coloscopy is a new diagnostic method that allows the presentation of the whole colon using minimal invasive procedures. The method allows the detection of colorectal polyps and colorectal carcinomas. The book includes the following chapters: indications for CT colonography, diagnostic procedures, data processing and interpretation, diagnostic findings, preparation of the diagnostic result description and documentation, screening.

2009-07-01

238

Particle Swarm Optimization and gravitational wave data analysis: Performance on a binary inspiral testbed  

CERN Document Server

The detection and estimation of gravitational wave (GW) signals belonging to a parameterized family of waveforms requires, in general, the numerical maximization of a data-dependent function of the signal parameters. Due to noise in the data, the function to be maximized is often highly multi-modal with numerous local maxima. Searching for the global maximum then becomes computationally expensive, which in turn can limit the scientific scope of the search. Stochastic optimization is one possible approach to reducing computational costs in such applications. We report results from a first investigation of the Particle Swarm Optimization (PSO) method in this context. The method is applied to a testbed motivated by the problem of detection and estimation of a binary inspiral signal. Our results show that PSO works well in the presence of high multi-modality, making it a viable candidate ...

2010-01-01

239

Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasi...

2011-01-01

240

Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage  

Energy Technology Data Exchange (ETDEWEB)

The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.

1995-06-01

241

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

242

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in ...

2005-08-15

243

A Laplacian approach to multi-oriented text detection in video.  

Science.gov (United States)

In this paper, we propose a method based on the Laplacian in the frequency domain for video text detection. Unlike many other approaches which assume that text is horizontally-oriented, our method is able to handle text of arbitrary orientation. The input image is first filtered with Fourier-Laplacian. K-means clustering is then used to identify candidate text regions based on the maximum difference. The skeleton of each connected component helps to separate the different text strings from each other. Finally, text string straightness and edge density are used for false positive elimination. Experimental results show that the proposed method is able to handle graphics text and scene text of both horizontal and nonhorizontal orientation. PMID:20733217

2011-02-01

244

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of ...

2009-07-15

245

The mask detection technology for occluded face analysis in the surveillance system.  

Science.gov (United States)

The surveillance systems have been widely used in automatic teller machines (ATMs), banks, convenient stores, etc. For example, when a customer uses the ATM, the surveillance systems will record his/her face information. The information will help us understand and trace who withdrew money. However, when criminals use the ATM to withdraw illegal money, they usually block their faces with something (in Taiwan, criminals usually use safety helmets or masks to block their faces). That will degrade the purpose of the surveillance system. In previous work, we already proposed a technology for safety helmet detection. In this paper, we propose a mask detection technology based upon automatic face recognition methods. We use the Gabor filters to generate facial features and utilize geometric analysis algorithms for mask detection. The technology can give an early warning to save-guards when any "customer" or ...

2005-05-01

246

Results of UT training for defect detection and sizing technique using specimens with fatigue crack and SCC  

International Nuclear Information System (INIS)

At the importance increase of UT (ultrasonic testing) with the application of rules on fitness-for-service for nuclear power plants, JAPEIC (Japan power engineering and inspection corporation) started education training for defect detection and sizing technique. Weld joints specimen with EDM (Electro-Discharged Machining) notches, fatigue cracks and intergranular stress corrosion cracks were tested and practiced repeatedly based on a modified ultrasonic method and the defect size measuring accuracy of the trainees was surely improved. Results of the blind test confirmed effectiveness of education training. (T. Tanaka)

2005-04-01

247

On the Generation of a Robust Residual for Closed-loopControl systems that Exhibit Sensor Faults  

DEFF Research Database (Denmark)

This paper presents a novel design methodology, based on shaping the system frequency response, for the generation of an appropriate residual signal that is sensitive to sensor faults in the presence of model uncertainty and exogenous unknown (unmeasured) disturbances. An integrated feedback controller design and robust frequency-based fault detection approach is proposed for Single-Input/Single-Output systems. The effciency of the proposed method is demonstrated on a Single Machine Innite Bus (SMIB) power system that achieves a coordinate power system stabilizer with satisfactory sensor fault detection capabilities.

2007-01-01

248

Method for limiting scram discharge water  

International Nuclear Information System (INIS)

Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).

249

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening.

1987-08-01

250

Lung cancer screening program using annual chest radiographs with computed radiography (FCR)  

International Nuclear Information System (INIS)

In the Wajima lung cancer screening program conducted under the auspices of Kanazawa University Hospital, Fuji Computed Radiography (FCR) was utilized in a new chest radiography trial. The results of the screening program are that the necessity of repeat examinations due to poor image quality are less common and the method enables detection of small pulmonary nodular shadows which are possibly candidates for surgery. Oblique chest X-ray with FCR is remarkably effective for the detection and the identification of small lesions. However, the disadvantage of slow processing and high cost must be fully satisfied if FCR is to become a new imaging modality for mass screening. (author).

1987-01-01

251

Leak detection on petroleum pipelines  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a unique method, currently under evaluation, that can continuously track pipeline operation providing essentially instantaneous responses to leaks or ruptures without causing a pressure drop or energy loss. Using the highly linear characteristics of a very accurate and repeatable meter and then correlating it to a second identical unit, a dynamic leak detection system is planned that can be retrofitted on existing pipelines without a major construction effort nor destroying the integrity of the existing transmission line. Initial tests performed on a crude oil transmission line verified the equipment's performance and established that the repeatability limits are sufficient to continue development of the concept.

1984-04-01

252

Generation and detection of superstrong shock waves during ablation of an aluminum surface by intense femtosecond laser pulses  

British Library Electronic Table of Contents (United Kingdom)

Superstrong shock waves of multimegabar level generated during ablation of an aluminum surface by intense (<1 PW/cm2) femtosecond laser pulses have been detected by observing the propagation of a shock wave in air from the ablated surface to a broadband piezoelectric receiver. The estimated initial pressure and velocity of the shock wave (ablation plume) agree well with data obtained earlier by various methods for shock waves propagating inside ablated targets.

2011-01-01

253

Accurate determination of detection efficiency and self-absorption factors in measuring radon daughter  

International Nuclear Information System (INIS)

The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.

254

A Grafcet-based expert system for process control; Un systeme expert base sur le Grafcet pour le controle de procede  

Energy Technology Data Exchange (ETDEWEB)

This article describes a hierarchical and functional model for continuous process control aid. The expertise is represented by graphs from a simple functional restructuring of the Grafcet, which is the formalism used by the designers of the command-control program. The new structure is familiar to the operator, and it is settled in an expert system. The application built on the basis of this method detects some default types which are not detected by the control-command. It proposes a diagnosis to the operator, and can explain and justify the state of the process. (authors) 9 refs.

1997-11-01

255

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase  

British Library Electronic Table of Contents (United Kingdom)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60degreeC). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at hi...

2010-01-01

256

Identification and staging of bladder carcinoma  

International Nuclear Information System (INIS)

The purpose of the present study was to compare the effectiveness of MRI, CT and radioimmunoscintigraphy in the staging and detection of bladder cancers in 28 patients. We distinguish two groups: Group I included the tumour stages CIS-T_3_A and the second group the deep infiltrative tumours T_3_B-T_4. MRI was slightly superior to CT in respect of tumour staging (75% correct results as compared to 63%). No understaging occurred with MRI, whereas in 22% of the cases the stage of the tumour was underestimated using CT diagnostics. Overstaging occurred in 25% of the MRI and 15% of the CT-diagnostics, respectively. RIS cannot distinguish the tumour groups, and hence this method is useful only for the detection of the primary tumour and metastases. In 77% of cases the tumour was detected and in 15% the tumour could be safely excluded. (orig.).

257

Fault detection and diagnosis of a gearbox in marine propulsion systems using bispectrum analysis and artificial neural networks  

British Library Electronic Table of Contents (United Kingdom)

A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic sign...

2011-01-01

258

False discovery rate: setting the probability of false claim of detection  

CERN Document Server

When testing multiple hypothesis in a survey --e.g. many different source locations, template waveforms, and so on-- the final result consists in a set of confidence intervals, each one at a desired confidence level. But the probability that at least one of these intervals does not cover the true value increases with the number of trials. With a sufficiently large array of confidence intervals, one can be sure that at least one is missing the true value. In particular, the probability of false claim of detection becomes not negligible. In order to compensate for this, one should increase the confidence level, at the price of a reduced detection power. False discovery rate control is a relatively new statistical procedure that bounds the number of mistakes made when performing multiple hypothesis tests. We shall review this method, discussing exercise applications to the field of gravitational wave surveys.

2005-01-01

259

Ergosterol analyses of oil palm seedlings and plants infected with Ganoderma  

British Library Electronic Table of Contents (United Kingdom)

Basal stem rot of oil palm (OP) by Ganoderma boninense is of major economic concern and it is the predominant disease of OP in SE Asia. Also, other plantation crops are affected by Ganoderma. The early detection of symptoms is crucial for control, although effective methods remain elusive. Ergosterol is the principal sterol of fungi and plays an essential role in the cell membrane and other cellular constituents. The analysis of ergosterol is useful for fungal detection in solid plant substrates. The present report compares ergosterol concentration in sound and decayed OP seedlings and mature plants using HPLC with diode array detection. The disease of OP requires to be considered as a white rot process where fungal biomass will increase from a low to high level as the infection progresses...

2011-01-01

260

Direct detection of Salmonella without pre-enrichment in milk, ice-cream and fruit juice by PCR against hilA gene  

British Library Electronic Table of Contents (United Kingdom)

A novel PCR based assay was devised to specifically detect contamination of any Salmonella serovar in milk, fruit juice and ice-cream without pre-enrichment. This method utilizes primers against hilA gene which is conserved in all Salmonella serovars and absent from the close relatives of Salmonella. An optimized protocol, in terms time and money, is provided for the reduction of PCR contaminants from milk, ice-cream and juice through the use of routine laboratory chemicals. The simplicity, efficiency (time taken 3-4 h) and sensitivity (to about 5-10 CFU/ml) of this technique confers a unique advantage over other previously used time consuming detection techniques. This technique does not involve pre-enrichment of the samples or extensive sample processing, which was a pre-requisite in mos...

2012-01-01

261

Diagnostic and Prognostic Utility of t(14;18) in Follicular Lymphoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract Background: Follicular lymphoma (FL) is one of the most common non-Hodgkin's lymphomas of B cells, being closely associated with a t(14;18) translocation. Detection of t(14;18), which is present in 70-95% of FL, might aid in FL diagnosis. Objective: To compare the efficacy of routine polymerase chain reaction (PCR) and fluorescence in situ hybridization (FISH) techniques in detecting t(14;18) in paraffin-embedded tissue samples of FL patients at different stages. Combined with other immunophenotypic biological determinants, detection of t(14;18) might help to determine patients at increased risk according to the FL International Prognostic Index (FLIPI) and therefore facilitate appropriate treatment. Design and Methods: This study was mainly based on a retrospective examination of...

2007-01-01

262

Determination of low-molecular-weight organic acids and inorganic anions by gradient elution chromatography  

Energy Technology Data Exchange (ETDEWEB)

Conditions of the separation and detection of organic and inorganic anions by gradient ion chromatography and suppressed conductivity detection were studied, and the procedure of gradient elution was optimized. A detection limit of 1 x 10{sup -3} {mu}g x L{sup -1} was obtained using the pre-concentrated column and most relative standard deviations obtained in the determination of seven organic and inorganic anions were below 5%. This method was proved to be simple, rapid and accurate for the separation and determination of low-molecular-weight organic acids and inorganic anions and could be applied in the analysis of the samples from water and steam systems of thermal power plants with satisfactory results. (orig.)

2007-03-15

263

Detecting hot spots at hazardous-waste sites  

Energy Technology Data Exchange (ETDEWEB)

Evaluating the need for remedial cleanup at a waste site involves both finding the average contaminant concentration and identifying highly contaminated areas, or hot spots. A nomographic procedure to determine the sample configuration needed to locate a hot spot is presented. The technique can be used to develop a waste-site sampling plant - to determine either the grid spacing required to detect a hot spot at a given level of confidence, or the probability of finding a hot spot of a certain size, given a particular grid spacing. The method and computer program (ELIPGRID) were developed for locating geologic deposits, but the basic procedure can also be used to detect hot spots at chemical- or nuclear-waste disposal sites. Nomographs based on the original program are presented for three sampling-grid configurations - square, rectangular and triangular.

1984-07-09

264

A Comprehensive Survey of Data Mining-based Fraud Detection Research  

CERN Document Server

This survey paper categorises, compares, and summarises from almost all published technical and review articles in automated fraud detection within the last 10 years. It defines the professional fraudster, formalises the main types and subtypes of known fraud, and presents the nature of data evidence collected within affected industries. Within the business context of mining the data to achieve higher cost savings, this research presents methods and techniques together with their problems. Compared to all related reviews on fraud detection, this survey covers much more technical articles and is the only one, to the best of our knowledge, which proposes alternative data and solutions from related domains.

2010-01-01

265

An innovative method of providing total breaker failure protection  

Energy Technology Data Exchange (ETDEWEB)

Breaker failure relaying has been generally achieved through the use of a current monitoring relay to determine whether current continues to flow into a fault after a breaker has been instructed to interrupt the circuit. If current continues to flow after a predefined period of time, the circuit breaker is considered to have failed. Steps must then be taken to trip the next set of upstream breakers in the power system to remove the faulted circuit and prevent system damage. However, with industrial power systems, this may be the utility`s breakers on the feeding transmission line. Regardless, breaker failure schemes must be designed to isolate both the faulted circuit and the failed circuit breaker. This paper discusses a new and innovative method of protecting a circuit breaker from the failure described above, plus other failures that go unprotected with conventional schemes, this providing total breaker failure protection.

1996-09-01

266

Method for syndrome coding and its application to fast hardware data selection based on the processors operating in the GF(2sup(m)) Galois field  

International Nuclear Information System (INIS)

The method of syndrome coding for data compression read out from multiwire proportional chambers that has been previously proposed is generalized in case of its application to registration of the coordinates of events detected. The questions of execution of arithmetic and algebraic operations on the Galois field elements and their hardware implementation are considered. The method of computation is presented of a specialized processor for parallel computing the coordinates of three sparks. The estimate of its speed is equal to 185 ns. Data compression, data selection and coordinate calculations are performed without use of memory elements and timing pulses.

267

Coverage and large scale anisotropies estimation methods for the Pierre Auger Observatory  

Energy Technology Data Exchange (ETDEWEB)

When searching for anisotropies in the arrival directions of Ultra High Energy Cosmic Rays, one must estimate the number of events expected in each direction of the sky in the case of a perfect isotropy. We present in this article a new method, developed for the Auger Observatory, based on a smooth estimate of the zenith angle distribution obtained from the data itself (which is essentially unchanged in the case of the presence of a large scale anisotropy pattern). We also study the sensitivity of several methods to detect large-scale anisotropies in the cosmic ray arrival direction distribution : Rayleigh analysis, dipole fitting and angular power spectrum estimation.

2005-07-01

268

Analytical methods for heavy metals in herbal medicines  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction - It is estimated that about 70-80% of the world's population relies on non-conventional medicine, mainly of herbal origin. However, owing to the nature and sources of herbal medicines, they are sometimes contaminated with toxic heavy metals such as lead, arsenic, mercury and cadmium, which impose serious health risks to consumers. It is critical to analyse source materials for heavy metals in order to ensure that their concentrations meet the related standards or regulations limiting their concentrations in herbal medicines. In this review, different analytical methods for analysis of heavy metals in herbal medicines are discussed. Objective - To provide a comprehensive review of the current state of the art in analytical methods used to detect heavy metals in herbal...

2011-01-01

269

An optical fiber methane sensing system employing a two-step reference measuring method  

British Library Electronic Table of Contents (United Kingdom)

An optical fiber methane sensing system utilizing a super-luminescent diode (SLD) in the 1.33-mm band and a fiber Fabry-Perot tunable filter (FFP-TF) is developed. A two-step reference measuring method, which is based on differential absorption technique, is employed; a reference channel is introduced to eliminate the fluctuation of the illuminant spectrum, and the reference wavelength acquired by tuning the FFP-TF is introduced to eliminate the environmental influence. The two-step reference measuring method has improved the reliability and stability of the system. A minimum detectable methane concentration of 0.3% has been experimentally achieved.

2008-01-01

270

Features of laser damage to elastic polymers  

Energy Technology Data Exchange (ETDEWEB)

Threshold pump intensity values leading to irreversible damage to colored laser elements based on elastic polymers were measured. The damage to colored elastomers is connected with absorbing microinclusions but is independent of molecular absorption. It is shown that damage to the elastomers has a pronounced threshold character in contrast to the microdamage accumulation effect in glassy polymers. The damage threshold for elastomers is 1.5 times higher, which is connected with the absence of microstresses (characteristics for organic glasses) in the specimens. 13 references.

1988-03-01

271

Statistical Methods and Software for the Analysis of Occupational Exposure Data with Non-detectable Values  

Energy Technology Data Exchange (ETDEWEB)

Environmental exposure measurements are, in general, positive and may be subject to left censoring; i.e,. the measured value is less than a ''detection limit''. In occupational monitoring, strategies for assessing workplace exposures typically focus on the mean exposure level or the probability that any measurement exceeds a limit. Parametric methods used to determine acceptable levels of exposure, are often based on a two parameter lognormal distribution. The mean exposure level, an upper percentile, and the exceedance fraction are used to characterize exposure levels, and confidence limits are used to describe the uncertainty in these estimates. Statistical methods for random samples (without non-detects) from the lognormal distribution are well known for each of these situations. In this report, methods for estimating these quantities based on ...

2005-09-20

272

Assessment of soil-gas, soil, and water contamination at the former 19th Street landfill, Fort Gordon, Georgia, 2009-2010  

Science.gov (United States)

Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the presence of total petroleum hydrocarbon (TPH) and octane above ...

2011-01-01

273

Computed tomography of the thorax: a status report  

Energy Technology Data Exchange (ETDEWEB)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. ...

1981-11-01

274

Computed tomography of the thorax: a status report  

International Nuclear Information System (INIS)

Computed tomography (CT) of the thorax shows early promise of important diagnostic advances. We believe that CT often provides information superior to that provided by standard roentgenographic techniques, is capable of significantly influencing patient management, and in selected instances, offers unique information not available by other methods. Computed tomography permits the imaging of mediastinal structures not possible with conventional roentgenographic methods and can diagnose with certainty benign mediastinal conditions such as pericardial cysts and focal or diffuse accumulations of fat. It is ideal for detecting pleural abnormalities and for displaying underlying parenchymal disease in patients with complex pleuroparenchymal shadows on conventional films. Pulmonary metastases unseen on the plain chest film can be detected with greater sensitivity than by any other method. ...

275

Waterjet resection of brain metastases - first clinical results with 10 patients.  

Science.gov (United States)

The waterjet technique enables precise tissue dissection without thermal damage and with preservation of vessels in general surgery. In neurosurgery, these qualities could help to avoid damage of intact brain parenchyma in tumour resections. The present study reports our first results with this technique in brain metastases. Ten patients with intracranial metastases underwent surgery with the aid of the waterjet. Resection was performed in combination with conventional neurosurgical methods. The follow-up consisted of neurological examination and MRI studies. Intraoperatively, the device was easy to handle. No complications due to the device were observed. Vessels were preserved at pressures below 20 bars. Six of the tumours consisted of soft tissue which was poorly demarcated from the surrounding brain. In these tumours, the waterjet was very helpful. It enabled tumour debulking by aspiration and - more important - precise ...

2003-05-01

276

Understanding and controlling transient enhanced dopant diffusion in silicon  

Energy Technology Data Exchange (ETDEWEB)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during initial annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, the authors have used B doping marker layers in Si to probe the injection of interstitials from near-surface, non-amorphizing Si implants during annealing. The in-diffusion of interstitials is limited by trapping at impurities and has an activation energy of {approximately}3.5 eV. Substitutional C is the dominant trapping center with a binding energy of 2--2.5 eV. The high interstitial supersaturation adjacent to the implant damage drives substitutional B into metastable clusters at concentrations below the B solid solubility limit. Transmission electron microscopy shows that the interstitials driving TED are emitted from {l_brace}311{r_brace} defect clusters in the damage region at a rate which also exhibits an activation energy of 3.6 ...

1995-12-31

277

Understanding and controlling transient enhanced dopant diffusion in silicon  

International Nuclear Information System (INIS)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during initial annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, the authors have used B doping marker layers in Si to probe the injection of interstitials from near-surface, non-amorphizing Si implants during annealing. The in-diffusion of interstitials is limited by trapping at impurities and has an activation energy of #approx#3.5 eV. Substitutional C is the dominant trapping center with a binding energy of 2--2.5 eV. The high interstitial supersaturation adjacent to the implant damage drives substitutional B into metastable clusters at concentrations below the B solid solubility limit. Transmission electron microscopy shows that the interstitials driving TED are emitted from #left brace#311#right brace# defect clusters in the damage region at a rate which also exhibits an activation energy of 3.6 ...

278

Thermal diffusivity measurements of irradiated UO_2 pellets  

International Nuclear Information System (INIS)

Thermal diffusivity was measured with a laser flash method up to 2000 K for UO_2 pellets irradiated in a commercial reactor. Measurements were done on micro samples of disks (2 mm diameter) or regular prisms (1.5 or 2 mm square cross sections). Thermal diffusivity degraded on extending burnup in agreement with reported values for UO_2 irradiated in test reactors, and it showed hysteresis during the laser flash experiments. Thermal diffusivity began to recover above 750 K and almost completely recovered above 1400 K, which corresponded with the reported radiation damage recovery. The obtained data were in agreement with predictions applying the thermal conductivity expression for irradiated UO_2 proposed by Amaya and Hirai. The sample experiencing power ramp showed higher thermal diffusivity than that of the base irradiated sample and had no obvious hysteresis. This suggested that the radiation damage which degraded thermal ...

1998-08-01

279

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).

280

Radiation damage and hardening of molybdenum in 29 MeV alpha particle straggling zone  

International Nuclear Information System (INIS)

Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.

281

Dose, exposure time, and resolution in Serial X-ray Crystallography  

CERN Document Server

The resolution of X-ray diffraction microscopy is limited by the maximum dose that can be delivered prior to sample damage. In the proposed Serial Crystallography method, the damage problem is addressed by distributing the total dose over many identical hydrated macromolecules running continuously in a single-file train across a continuous X-ray beam, and resolution is then limited only by the available molecular and X-ray fluxes and molecular alignment. Orientation of the diffracting molecules is achieved by laser alignment. We evaluate the incident X-ray fluence (energy/area) required to obtain a given resolution from (1) an analytical model, giving the count rate at the maximum scattering angle for a model protein, (2) explicit simulation of diffraction patterns for a GroEL-GroES protein complex, and (3) the frequency cut off of the transfer function following iterative solution of the phase problem, and reconstruction ...

2007-01-01

282

Corrosion test and service result of materials used for fuel injection nozzles in marine diesel engines  

Energy Technology Data Exchange (ETDEWEB)

Corrosion test, as a material selection test method of nozzle to be used in the marine diesel engine, was adopted and discussed. Due to the heightening in output power and lengthening in stroke of the marine diesel engine, the fuel injection nozzle became so severe in working condition that the nozzle tip became in lift 1/6 to 1/18 time as long as that of short stroke type in past. Then upon investigating cause of damage, the damage was confirmed to be mainly caused by the high temperature sulfidization corrosion. Then by preparing 20 kinds of candidate test piece and making sulfidization corrosion test in accordance with the high temperature corrosion test procedure, corrosiveness was evaluated through change in weight between before and after testing. As a result of testing, three kinds of test piece, inclusive of high Ni-Cr-Al alloy's, showed a high anti-corrosiveness. Those kinds of test piece were then field ...

1989-06-15

283

The influence of different SPECT reconstruction algorithms on cardiac ischemia with the use artificial neural networks  

International Nuclear Information System (INIS)

The aim of the study was the attempt to evaluate the influence of two different methods of cardiac perfusion SPECT reconstruction (FBP and ITW) on clinical efficacy in diagnosing the coronary artery disease as well as the cardiac ischemia detection in three areas of heart vascularized by main coronary arteries: LAD, LCX and RCA with the use of artificial neural networks (ANN). The study was performed retrospectively with the use of the diagnostic image records as well as clinical dataset of 43 patients. Myocardial perfusion stress/rest SPECT study and X-ray coronarography data were evaluated for each patient. The results of coronary angiography were considered the reference method. The cardiac SPECT data were reconstructed using the two different methods: filtered backprojection (FBP) and iterative Wallis method (ITW). The local perfusion deficits denominated in stress and rest ...

284

Statistical methods for environmental pollution monitoring  

Energy Technology Data Exchange (ETDEWEB)

This volume covers planning, design, and data analysis. It offers statistical methods for designing environmental sampling and monitoring programs as well as analyzing the resulting data. Statistical sample survey methods to problems of estimating average and total amounts of environmental pollution are presented in detail. The book also provides a broad array of statistical analysis methods for many purposes...numerous examples...three case studies...end-of-chapter questions...computer codes (showing what output looks like along with its interpretation)...a discussion of Kriging methods for estimating pollution concentration contours over space and/or time...nomographs for determining the number of samples required to detect hot spots with specified confidence...and a description and tables for conducting Rosner's test to identify outlaying (usually large) pollution ...

1986-01-01

285

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average ...

1992-11-12

286

Development of a leak location system for use on underground electric power transmission cable. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes a study to evaluate methods for locating leaks of dielectric fluid from buried high-voltage cable systems. Two primary types of leak location systems were investigated: (1) systems that will rapidly isolate the leak within a manhole section, typically 1000-m long on a feeder that might be 30-km long; and (2) systems that will then pinpoint the location of the leak. Rapid leak isolation was accomplished by developing an enhanced conductivity oil probe which allows the injection of a small quantity of conductive oil and which indicates the path of the oil as it drifts downstream in the direction of the leak. Two methods for pinpointing the leak were proven. The more successful method was the use of trained leak location dogs which were found to have far better sensitivity than instruments and which could detect cable oil alone without the need for additives. A tracer gas injection ...

1982-10-01

287

Performance Evaluation of Several Types of Pulsed Eddy Current Probes for Detecting Wall Thickness Reduction  

Science.gov (United States)

In this paper, four different types of pulsed eddy current (PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction is achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the ...

2010-02-01

288

Partial unmixing as a tool for single surface class detection and time series analysis  

British Library Electronic Table of Contents (United Kingdom)

In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...

2008-01-01

289

No evidence of over-reporting of SARS in mainland China  

British Library Electronic Table of Contents (United Kingdom)

Summary Objective To find out whether there was over-reporting of SARS patients in mainland China in view of the relatively low case fatality ratio in mainland China, in comparison with other affected countries and areas. Methods We searched PubMed for all SARS antibody detection papers (in English or Chinese language) using the keywords `SARS' and `antibody'. Then the resulting articles were further read through to select the SARS detection results using ELISA methods of serum samples collected at least 1 month after disease onset. A multi-level logistic regression was applied to test for possible differences in the proportions positive between locations of the study. Results A total of 48 studies were identified, including 39 from mainland China and nine from elsewhere (Hong Kong, Taiwan...

2009-01-01

290

Gear fault detection using customized multiwavelet lifting schemes  

British Library Electronic Table of Contents (United Kingdom)

Fault symptoms of running gearboxes must be detected as early as possible to avoid serious accidents. Diverse advanced methods are developed for this challenging task. However, for multiwavelet transforms, the fixed basis functions independent of the input dynamic response signals will possibly reduce the accuracy of fault diagnosis. Meanwhile, for multiwavelet denoising technique, the universal threshold denoising tends to overkill important but weak features in gear fault diagnosis. To overcome the shortcoming, a novel method incorporating customized (i.e., signal-based) multiwavelet lifting schemes with sliding window denoising is proposed in this paper. On the basis of Hermite spline interpolation, various vector prediction and update operators with the desirable properties of biorthog...

2010-01-01

291

Dynamic construction of outage lists for safety analysis of power transmission lines. Dynamische Erstellung von Ausfallisten fuer die Sicherheitsanalyse elektrischer Energieuebertragungssysteme  

Energy Technology Data Exchange (ETDEWEB)

An adaptive contingency selection process is set up which produces outage lists in order to guarantee on-line network security control. The quality index system used so far did not detect and reveal all critical variables due to observation problems in the mapping of two functions. The new process uses the results of the outage simulation computing of the system status just past for the drawing up of an up-to-date outage list. A linear correcting function transform the G{sub 2}-values of the standard quality index method - which still incorporate the observation problem effect - into improved values G. Studies which use data from realstic high-voltage networks prove that the detection of critical variables is far superior to ordinary methods. (orig.).

1990-04-23

292

Determination and removal of malondialdehyde and other 2-thiobarbituric acid reactive substances in waste cooking oil  

British Library Electronic Table of Contents (United Kingdom)

Waste cooking oil can be recovered and processed into animal feed additives after purification. Unfortunately, the traditional purification processes are insufficient for the removal of the harmful compounds formed during frying, mainly about malondialdehyde and other 2-thiobarbituric acid reactive substances. In the present paper, firstly, a simple and reliable HPLC method was developed to measure the content of malondialdehyde in purified waste cooking oil. The detection limit and the standard recovery of the analysis method are 1.20x10-5gl-1 and 96.5-99.2%, respectively, which is accurate and valid enough for the detection of malondialdehyde in waste cooking oil. Furthermore, the removal of malondialdehyde and other 2-thiobarbituric acid reactive substances from waste cooking oil was in...

2011-01-01

293

Biomagnetic separation of Salmonella Typhimurium with high affine and specific ligand peptides isolated by phage display technique  

Energy Technology Data Exchange (ETDEWEB)

Analyses of food-borne pathogens are of great importance in order to minimize the health risk for customers. Thus, very sensitive and rapid detection methods are required. Current conventional culture techniques are very time consuming. Modern immunoassays and biochemical analysis also require pre-enrichment steps resulting in a turnaround time of at least 24 h. Biomagnetic separation (BMS) is a promising more rapid method. In this study we describe the isolation of high affine and specific peptides from a phage-peptide library, which combined with BMS allows the detection of Salmonella spp. with a similar sensitivity as that of immunomagnetic separation using antibodies.

2007-04-15

294

From Attachment to Damage: Defined Genes of Candida albicans Mediate Adhesion, Invasion and Damage during Interaction with Oral Epithelial Cells  

UK PubMed Central (United Kingdom)

Candida albicans frequently causes superficial infections by invading and damaging epithelial cells, but may also cause systemic infections by...Full Text Available

295

DNA Damage during G2 Phase Does Not Affect Cell Cycle Progression of the Green Alga Scenedesmus quadricauda  

UK PubMed Central (United Kingdom)

DNA damage is a threat to genomic integrity in all living organisms. Plants and green algae are particularly susceptible to DNA damage especially that caused by UV light, due to their light dependency...Full Text Available

296

Beam-induced damage on diffractive hard X-ray optics  

UK PubMed Central (United Kingdom)

The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available

2010-11-01

297

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase.  

Science.gov (United States)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60 degrees C). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at high temperatures is desired to weaken or melt secondary structure motifs. To demonstrate the ability of Taq M1 for RNA ...

2010-02-01

298

A pilot application of risk-based methods to establish in-service inspection priorities for nuclear components at Surry Unit 1 Nuclear Power Station  

International Nuclear Information System (INIS)

As part of the Nondestructive Evaluation Reliability Program sponsored by the US Nuclear Regulatory Commission, the Pacific Northwest Laboratory is developing a method that uses risk-based approaches to establish in-service inspection plans for nuclear power plant components. This method uses probabilistic risk assessment (PRA) results and Failure Modes and Effects Analysis (FEMA) techniques to identify and prioritize the most risk-important systems and components for inspection. The Surry Nuclear Power Station Unit 1 was selected for pilot applications of this method. The specific systems addressed in this report are the reactor pressure vessel, the reactor coolant, the low-pressure injection, and the auxiliary feedwater. The results provide a risk-based ranking of components within these systems and relate the target risk to target failure probability values for individual components. These results will be used to guide ...

299

Development of methodics for the characterization of the composition of the ion-collision-induced secondary-particle flux by comparison of the yield contributions of photoinduced ion formation processes; Entwicklung einer Methodik zur Charakterisierung der Zusammensetzung des ionenbeschussinduzierten Sekundaerteilchenflusses durch Vergleich der Ausbeuteanteile photoinduzierter Ionenbildungsprozesse  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to develop a method to distinguish between different ion formation processes and to determine the influence of these processes on the total number of detected monatomic ions of a certain element. A vector/matrix-formalism was developed, which describes the physical processes of sputtering, ion formation, mass separation and detection in laser-SNMS. In the framework of the method developed, based on this theoretic formalism, changes in the secondary flux contribution of the respective element were observed by comparing the detected monatomic ion yield obtained in specifically aligned (SIMS and) laser-SNMS experiments. The yields resulting from these experiments were used to calculate characteristic numbers to compare the flux composition from different surfaces. The potential of the method was demonstrated for the elements boron, iron and ...

2008-10-13

300

Vertebrate Damage Control Research in Agriculture, Fiscal ...  

Science.gov (United States)

... The revised work plan emphasized the research priorities of preharvest rodent damage to rice, the importance of postharvest food losses to rodents ...

1993-09-30

301

Size Effects in Impact Damage of Composite Sandwich Panels Alan ...  

Science.gov (United States)

Wade. Jackson. - Army. VTD at NASA. Langley. ABSTRACT. Panel size has a large effect on the impact response and resultant damage level of honeycomb sandwich ...

302

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compounds in EBR-II and FFTF  

Energy Technology Data Exchange (ETDEWEB)

Radiation Damage Calculations for the FUBR and BEATRIX Irradiations of Lithium Compunds in EBR-II and FFTF

1999-05-01

303

Oxidative Damage and the Prevention of Age-Related Cataracts  

UK PubMed Central (United Kingdom)

PurposeCataracts are often considered to be an unavoidable consequence of aging. Oxidative damage is a major cause or consequence of cortical and nuclear cataracts, the most common...Full Text Available

2010-09-01

305

ESR study in radiation damage in pyrimidines. 3-year comprehensive progress report  

International Nuclear Information System (INIS)

General mechanisms of radiation damage to biomolecules was studied by using substituted pyrimidines, particularly barbituric acid derivatives.

306

The detection of spiral arm modulation in the stellar disk of an optically flocculent and an optically grand design galaxy  

CERN Document Server

Two dimensional Fourier spectra of near-infrared images of galaxies provide a powerful diagnostic tool for the detection of spiral arm modulation in stellar disks. Spiral arm modulation may be understood in terms of interference patterns of outgoing and incoming density wave packets or modes. The brightness along a spiral arm will be increased where two wave crests meet and constructively interfere, but will be decreased where a wave crest and a wave trough destructively interfere. Spiral arm modulation has hitherto only been detected in grand design spirals (such as Messier 81). Spiral arm amplitude variations have the potential to become a powerful constraint for the study of galactic dynamics. We illustrate our method in two galaxies: NGC 4062 and NGC 5248. In both cases, we have detected trailing and leading m=2 waves with similar pitch angles. This suggests that the amplification mechanism is the ...

2000-01-01

307

Real World Evaluation of Dual-Zone ICD and CRT-D Programming Compared to Single-Zone Programming: The ALTITUDE REDUCES Study  

British Library Electronic Table of Contents (United Kingdom)

Tachycardia Detection, ICD, CRT-D Devices, Appropriate and Inappropriate Shock.-Introduction: We evaluated the frequency of appropriate and inappropriate shocks and survival in patients using dual-zone programming versus single-zone programming. Methods and Results: For the ALTITUDE REDUCES study, patients were followed for 1.6 1.1 years. The 12-month incidence of any shock was lower for dual-versus single-zone programmed detection at rates -170 bpm and between 170-200 bpm (P < 0.001). Appropriate shock rates at 1 year were also lower with dual-zone programming in these rate intervals (single zone 9.1%, 5.4%, P < 0.001, dual zone 6.7%, 4.7%, P < 0.02). There were no detectable differences between single- and dual-zone shock incidence at detection rates - 200 bpm (P = 0.14). Inappropriate s...

2011-01-01

308

Pressure based leak detection system implanted on the business Unit Exploration and Production of PETROBRAS in Rio Grande do Norte e Ceara; Sistema de deteccao de vazamentos em dutos baseado em pressao implantado na Unidade de Negocios de Exploracao e Producao da PETROBRAS no Rio de Grande do Norte e Ceara  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the experience faced by people who works in PETROBRAS Business Unit (UN-RNCE), located in Rio Grande do Norte Province, Brazil, during the implementation of a pipeline leak detection system. That application involved nine multiphase oil pipelines distributed along several production facilities. Because of the emergency after the leakage that polluted the Guanabara bay and due to the two phases and multi phases pipelines characteristics, the UN-RNCE decided to apply the Pressure Point Analysis (PPA) technology in order to detect leakages. It is a statistical method for leak detection e uses a very simple instrumentation which facilitates the installation and maintenance. However, in order to get the best performance of the system, it is necessary to know thoroughly the whole process and have a fast and reliable SCADA system for long distance communication. Finally it will be shown the ...

2003-07-01

309

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed ...

2009-11-02

310

Turbine blade protective coat damage; Schutzschichtschaeden an Gasturbinenschaufeln  

Energy Technology Data Exchange (ETDEWEB)

Damage survey of protective coats of modern gas turbine blade shows that most damages are not due to classic wear mechanisms such as oxydation or high-temperature corrosion but caused by foreign bodies, poor coating during manufacturing, or operation-caused cracks. Mere visual inspection of cracks is often not sufficient to tell whether cracks are superficial or whether they have already progressed into the base material. Non-destructive methods such as ultrasonic inspection or eddy-current testing are helpful tools but there is not yet a fully matured testing concept at hand. Metallographical tests can give important information about crack mechanisms and thermal, chemical and mechanical stresses.(orig.) [German] Die Schadenerfahrung mit Schutzschichten moderner Gasturbinenschaufeln zeigt, dass die meisten Schaeden nicht auf die klassischen Verbrauchsmechanismen wie Oxydation und Hochtemperaturkorrosion zurueckzufuehren ...

1998-07-01

311

Propolis derivatives inhibit the systemic inflammatory response and protect hepatic and neuronal cells in acute septic shock  

Scientific Electronic Library Online (English)

Abstract in english BACKGROUND: Severe pathogenic infection triggers excessive release of cytokines as part of the massive inflammatory response associated with septic shock. OBJECTIVES: To investigate the protective effect of caffeic acid phenethye ester (CAPE) against lipopolysaccharide (LPS) induced endotoxemia, hepatic and neuronal damage and the associated systemic inflammatory response (SIR). METHODS: Fifty male Wister rats were divided into: control, LPS, and CAPE+LPS groups. Plasma c (more) oncentrations of various cytokines, including TNF-?, IL-1?, IL-1?, IL-6, IL-4, IL-10, and sICAM-1 were evaluated. In addition, the histopathological changes in the hepatic and neural cells were assessed. RESULTS: The LPS group showed high inflammatory cytokines and sICAM-1 levels reflecting the presence of SIR. Hepatocyte necrosis, apoptosis, extensive hemorrhage and inflammatory cellular infiltration together with brain astrocytes swelling, early ...

2011-08-01

312

Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon  

Energy Technology Data Exchange (ETDEWEB)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5{times}10{sup 12} to 1{times}10{sup 14}/cm{sup 2} evolves into a distribution of {l_brace}311{r_brace} interstitial agglomerates during the initial annealing stages at 670{endash}815{degree}C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution ...

1997-05-01

313

Physical mechanisms of transient enhanced dopant diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

Implanted B and P dopants in Si exhibit transient enhanced diffusion (TED) during annealing which arises from the excess interstitials generated by the implant. In order to study the mechanisms of TED, transmission electron microscopy measurements of implantation damage were combined with B diffusion experiments using doping marker structures grown by molecular-beam epitaxy (MBE). Damage from nonamorphizing Si implants at doses ranging from 5x10"1"2 to 1x10"1"4/cm"2 evolves into a distribution of #left brace#311#right brace# interstitial agglomerates during the initial annealing stages at 670 endash 815 degree C. The excess interstitial concentration contained in these defects roughly equals the implanted ion dose, an observation that is corroborated by atomistic Monte Carlo simulations of implantation and annealing processes. The injection of interstitials from the damage region involves the dissolution of #left ...

314

Hydroxyl radical formation by UV-irradiated epidermal cells  

International Nuclear Information System (INIS)

To elucidate the mechanism of sunlight-induced skin damage, guinea pigs exposed to UV light (280-320 nm, UV B, 4J/cm"2) and a homogenate of the epidermis was examined by means of the thiobarbituric acid (TBA) test. Three hours after the exposure, TBA-malondialdehyde adducts had increased while glutathione reductase activity had decreased, indicating lipid peroxidation. To detect the initial species, spin trapping with 5,5-dimethyl-1-pyrroline-N-oxide (DMPO) was applied to a suspension of illuminated epidermal cells (0.5 J/cm"2). An ESR signal obtained only with irradiation comprised a 1 : 2 : 2 : 1 quartet [a (N) =a (#beta#H) =1.49 mT] attributable to a spin adduct of hydroxyl radicals. These results suggest that sunlight exposure of skin may lead to hydroxyl radical generation and simultaneous lipid peroxidation. (author).

315

Extreme sensitivity of some intestinal crypt cells to X and #gamma# irradiation  

International Nuclear Information System (INIS)

Reference is made to Cheng and Leblond (Amer. J. Anat.; 141:537 (1974)) who used tritiated thymidine to kill cells synthesising DNA in the crypts of the small intestine. Amongst their findings was that very low doses caused measurable cell killing and that the killing was not random throughout the crypt but occurred selectively at the crypt base where stem cells are presumably located. It is here reported that the presence of hypersensitive cells at the base of the crypts can be demonstrated after whole-body X- or gamma-irradiation, and the time sequence for the production and loss of the killed cells is described together with their dose-response relationship. The studies were conducted on mice. The data were expressed as surviving rather than killed cells, and it was established that the crypt are amongst the most sensitive of mammalian cells. The mechanism by which these sensitive cells are killed is not known, but DNA damage can be ...

1977-10-01

316

Trans-generational radiation-induced chromosomal instability in the female enhances the action of chemical mutagens  

Energy Technology Data Exchange (ETDEWEB)

Genomic instability can be produced by ionising radiation, so-called radiation-induced genomic instability, and chemical mutagens. Radiation-induced genomic instability occurs in both germinal and somatic cells and also in the offspring of irradiated individuals, and it is characterised by genetic changes including chromosomal rearrangements. The majority of studies of trans-generational, radiation-induced genomic instability have been described in the male germ line, whereas the authors who have chosen the female as a model are scarce. The aim of this work is to find out the radiation-induced effects in the foetal offspring of X-ray-treated female rats and, at the same time, the possible impact of this radiation-induced genomic instability on the action of a chemical mutagen. In order to achieve both goals, the quantity and quality of chromosomal damage were analysed. In order to detect trans-generational genomic instability, a total of 4806 ...

2008-04-02

317

Pathogenesis of trypanosome infections in cattle  

International Nuclear Information System (INIS)

The potential application of radioisotopes are not discussed in this review of trypanosome pathogenesis in cattle. Initially, structural changes in the lymphoid system are characterized by marked proliferation and germinal centre formation, whereas in long-standing infections the lymphoid organs become depleted. These changes appear associated with immunodepression. Anaemia dominates the clinical disease syndrome in bovine trypanosomiasis. It develops with the onset of parasitaemia and is largely haemolytic, resulting from increased red blood cell destruction by phagocytosis. Several factors may be involved in this process including haemolysins produced by the trypanosome, immunological mechanisms, fever, disseminated intravascular coagulation and an expanded and active mononuclear phagocytic system. During this phase of the disease, cattle respond well to chemotherapy. However, in later phases of the disease, when trypanosomes cannot be detected, the anaemia ...

1979-05-11

318

Recent advances in analytical determination of cisplatin and its hydrolysis products  

International Nuclear Information System (INIS)

Cisplatin (cis-diaminedichloroplatinum [II] is a coordination compound, used in the treatment of several solid tumors. Cisplatin and its hydrolysis products exhibit a great pharmacological effect but are very toxic and probably carcinogenic. The present review summarizes the most important advances in the last years in the techniques employed for the detection and quantification of cisplatin and its hydrolysis products and in the different matrixes studied. The new emerging techniques and their modifications recently developed, fundamentally the combined use of detection and separation techniques for the analysis of platinum species and their impact on the speed, sensitivity and specificity of the analytical determination, with regard to the techniques used in the last century are discussed. High-Performance Liquid Chromatography and Capillary Electrophoresis, coupled with detection methods such as Mass ...

2009-01-01

319

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to ...

2007-08-21

320

Electrochemical detection of DNA hybridization based on silver-enhanced gold nanoparticle label  

Energy Technology Data Exchange (ETDEWEB)

An electrochemical detection method for analyzing sequence-specific DNA using gold nanoparticle DNA probes and subsequent signal amplification step by silver enhancement is described. The assay relies on the electrostatic adsorption of target oligonucleotides onto the sensing surface of the glassy carbon electrode (GCE) and its hybridization to the gold nanoparticle-labeled oligonucleotides DNA probe. After silver deposition onto gold nanoparticles, binding events between probe and target were monitored by the differential pulse voltammetry (DPV) signal of the large number of silver atoms anchored on the hybrids at the electrode surface. The signal intensity difference permits to distinguish between the match of two perfectly matched DNA strands and the near-perfect match where just one base pair was wrong. Coupled with this 'nanoparticle-promoted' reduction of silver signal amplification method, the ...

2002-10-03

321

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

322

European multicentre evaluation of the Super Aution SA-4220 urinalysis analyser.  

Science.gov (United States)

A multicentre evaluation of the urine test strip analyser Super Aution-4220 was carried out in six laboratories. The analytical performance of the instrument with regard to imprecision, linearity, detection limit, drift, carry-over and method comparison was studied. Using the Aution stick 8 test strip the pH, glucose, protein, ketones, bilirubin, blood, urobilinogen and leukocyte esterase were analysed. Specific gravity measurements were performed by refractive index method. Within-run and between-run imprecision determined at three levels of analyte were good. No carry-over was observed. Obtained results were linear through all the described analytical range. No significant drift was detected. Method comparison with some quantitative methods was performed and showed a good correlation with most of the analytes. The study of interferences showed minor ...

1998-12-01

323

Security of mobile agents: a new concept of the integrity protection  

CERN Document Server

The recent developments in the mobile technology (mobile phones, middleware) created a need for new methods of protecting the code transmitted through the network. The proposed mechanisms not only secure the compiled program, but also the data, that can be gathered during its "journey". The oldest and the simplest methods are more concentrated on integrity of the code itself and on the detection of unauthorized manipulation. Other, more advanced proposals protect not only the code but also the execution state and the collected data. The paper is divided into two parts. The first one is mostly devoted to different methods of securing the code and protecting its integrity; starting from watermarking and fingerprinting, up to methods designed specially for mobile agent systems: encrypted function, cryptographic traces, time limited black-box security, chained-MAC protocol, ...

2005-01-01

324

Optical dating: insufficiently bleached sediments  

International Nuclear Information System (INIS)

Although infrared-stimulated luminescence (IRSL) signals in feldspars can be bleached rapidly by sunlight, there could still be a small amount of IRSL signal remaining in sediment grains if they have experienced only relatively short sunlight exposure before deposition. This remaining signal results in a ''remnant dose'' stored in the grain and is important for young samples but negligible for old samples. Several methods have been introduced to detect insufficient bleaching, and some of them can provide information on the extent of the bleaching. Others can only distinguish between samples bleached for a very long time and for a short time. Empirical methods are introduced to evaluate the possible values of equivalent dose accumulated since the grains were deposited. These methods involve the analysis of the equivalent doses and the natural IRSL signals obtained using single-disc dose determination ...

1993-07-01

325

Headspace gas chromatographic method for determination of methyl bromide in food ingredients  

Energy Technology Data Exchange (ETDEWEB)

A headspace gas chromatographic (GC) method, which can be automated, has been developed for determination of methyl bromide. This method has been applied to wheat, flour, cocoa, and peanuts. Samples to be analyzed are placed in headspace sample vials, water is added, and the vials are sealed with Teflon-lined septa. After an appropriate equilibration time at 32 degrees C, the samples are analyzed within 10 h. A sample of the headspace is withdrawn and analyzed on a gas chromatograph equipped with an electron capture detector (ECD). Methyl bromide levels were quantitated by comparison of peak area with a standard. The standard was generated by adding a known amount of methyl bromide to a portion of the matrix being analyzed and which was known to be methyl bromide free. The detection limit of the method was 0.4 ppb. The coefficient of variation (CV) was 6.5% for wheat, 8.3% for flour, 3.3% for cocoa, and ...

1985-11-01

326

X-ray fluorescence analysis as auxiliary method of restorers  

International Nuclear Information System (INIS)

The principle is described of X-ray fluorescence analysis and the manner of detecting the emitted characteristic radiation. The advantages are presented of radionuclide X-ray fluorescence analysis which consist primarily in the possibility of conducting a totally non-destructive analysis, and of accurate and relatively narrow localization of the analyzed area, the simultaneous qualitative and quantitative determinations of a large number of elements in the order of concentrations 10"1 to 10"-"4%, stability of excitation radiation flux, simple design and relatively low capital costs. The so-called matrix effect is pointed to. A number of examples is given of the use of the cited method, including its use in the analysis of art objects. (J.B.).

1987-09-07

327

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

Energy Technology Data Exchange (ETDEWEB)

Doubly-excited 2s{sup -1}2p{sup -1}3pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

328

Observation of high-lying weak autoionizing resonances of Ne, and Mg atoms by charge-separated photoion-yield method  

International Nuclear Information System (INIS)

Doubly-excited 2s-12p-13pnp autoionizing resonance series of Ne atom as well as autoionizing resonances in the 2s region of Na and Mg atoms have been studied with monochromatized synchrotron radiation. Use of charge-separated photoion-yield method allowed us to detect these weak resonances in a clarified way in the yield curves of doubly-charged ions. The observed resonance states have been interpreted with the help of MCDF calculations, and the decay processes of these resonance states are discussed briefly.

2007-03-01

329

Method of combustion for dual fuel engine  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and a method of introducing a primary fuel, which may be a coal water slurry, and a high combustion auxiliary fuel, which may be a conventional diesel oil, into an internal combustion diesel engine comprises detecting the load conditions of the engine, determining the amount of time prior to the top dead center position of the piston to inject the main fuel into the combustion chamber, and determining the relationship of the timing of the injection of the auxiliary fuel into the combustion chamber to achieve a predetermined specific fuel consumption, a predetermined combustion efficiency, and a predetermined peak cylinder firing pressure. 19 figures.

1993-12-21

330

LET-dependence of the trapping parameters in TLD-100 determined with a computerised curve fitting method  

International Nuclear Information System (INIS)

With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).

1985-10-22

331

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

332

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

333

Uptake of oleate from albumin solutions by rat liver. Failure to detect catalysis of the dissociation of oleate from albumin by an albumin receptor.  

UK PubMed Central (United Kingdom)

The hepatic removal of albumin-bound substances from plasma requires that they dissociate from albumin. Using indirect methods, we and others have proposed that dissociation may be catalyzed by interaction...Full Text Available

1987-04-01

334

Uncommon bone tumors of the skull: Ewing's sarcoma and Triton's tumor  

International Nuclear Information System (INIS)

Ewing's sarcoma and Triton's tumor are two uncommon bone tumors of the skull that have nonspecific clinical and imaging features. However, imaging methods are important in the detection of the lesions during the diagnostic investigation in order to evaluate the extent of the bone lesions, involvement of the soft tissues and brain, and to determine the presence of local recurrence and metastases. The confirmatory diagnosis relies on histological studies and immunohistochemistry. The authors report two cases of patients with these tumors and present the radiological findings. (author)

335

Thorium different-ligand complexes with morin as analytic form for extraction-photometric determination of thorium microamounts  

International Nuclear Information System (INIS)

Consideration is given to results of investigation into thorium complexing with morin (H_2Mor) in extraction systems containing different carboxylic acids as well as different salt background. The obtained data enabled to suggest the method of photometric determination of thorium in the form of Th(HMor)_2Benz_2 different-ligand complex (where Benz-anion of benzilic acid) with 0.25 #mu#g/ml detection limit.

1989-01-01

336

Study of complexing reactions and ligand exchange of zirconium and hafnium tetrachlorides with substituted derivative of O-naphthoquinonediazide  

Energy Technology Data Exchange (ETDEWEB)

Using the PMR method the interaction of zirconium and hafnium tetrachlorides with tri.tet.butylphenyl ester of 1,2- naphthoquinonediazide (2)-5-sulfonic acid is studied. The formation of MCl/sub 4/xNQD complexes is established, the equilibrium constants and thermodynamic parameters of complexing reaction are determined. The presence of rapid ligand exchange, proceeding according to associative mechanism, is detected. The rate constants and activation energies of the exchange reaction are calculated.

1981-11-01

337

Study of complexing reactions and ligand exchange of zirconium and hafnium tetrachlorides with substituted derivative of O-naphthoquinonediazide  

International Nuclear Information System (INIS)

Using the PMR method the interaction of zirconium and hafnium tetrachlorides with tri.tet.butylphenyl ester of 1,2- naphthoquinonediazide (2)-5-sulfonic acid is studied. The formation of MCl_4xNQD complexes is established, the equilibrium constants and thermodynamic parameters of complexing reaction are determined. The presence of rapid ligand exchange, proceeding according to associative mechanism, is detected. The rate constants and activation energies of the exchange reaction are calculated.

338

Spectrophotometric technique quantitatively determines NaMBT inhibitor in ethylene glycol-water solutions  

Science.gov (United States)

Spectrophotometric method, using a ratio-recording ultraviolet-absorption spectrophotometer, permits analysis of NaMBT in ethylene glycol-water solutions with high accuracy. It reduces analysis time, requires smaller samples, and is able to detect extremely small concentrations of mercaptobenzothiazole.

1967-01-01

339

Spectrophotometric determination of rhenium with acetylacetone  

Energy Technology Data Exchange (ETDEWEB)

The optimum conditions of complex formation of rhenium(IV) with acetylacetone in water-ethanol medium were found, and a spectrophotometric method for determining rhenium with limit of detection 0.1 ..mu..g/ml was proposed. Rhenium can be determined in the presence of a 1000-fold excess of molybdenum. The procedure was tested on model solutions and used for the determination of rhenium in alloys.

1987-10-10

340

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

341

Potential U.S. contributions to in-reactor experiments for fast reactor surveillance systems  

International Nuclear Information System (INIS)

It is maintained that special features of FFTF make it an ideal system to test sodium boiling detection techniques by acoustic/neutronic methods and to test the response of acoustic/neutronic sensors to vibrations. It is shown that accumulated research results indicate that such tests in FFTF are feasible, predictable, promising and safe. (author).

342

Pollution control instrumentation for oil and effluents  

Energy Technology Data Exchange (ETDEWEB)

This book provides discusses recent developments in oil pollution control instrumentation. Some of the topics covered are as follows: 1. Technical requirements of the IMCO International Performance and Test Specification A393x concerning oil content meters; and 2. Oil in water detection; and 3. Methods for the disposal of recovered oil and oily sludge; and 4. Oil content monitoring at ballast water treatment facilities and offshore production platforms.

1986-01-01

343

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

344

Nitrogen isotope identification by Bragg-curve spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Projectilelike fragments following the 80 MeV /sup 16/O+/sup 27/Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.

1984-07-14

345

Nitrogen isotope identification by Bragg-curve spectroscopy  

International Nuclear Information System (INIS)

Projectilelike fragments following the 80 MeV "1"6O+"2"7Al reaction have been detected using a Bragg-curve spectroscopy ionization chamber (BCS-IC). The atomic number is deduced from the Bragg-peak amplitude. Nitrogen isotopes are clearly resolved using either range or energy loss data. This is the first application of the BCS method for complete ion identification in a heavy-ion-induced reaction.

346

Monitoring for Xenon Radionuclides and CTBT Verification  

International Nuclear Information System (INIS)

The Comprehensive Nuclear-Test-Ban-Treaty (CTBT), which was opened for signature in 1996, bans all nuclear explosions in all environments. Republic of Korea has been working to monitor compliance with CTBT by deterring and detecting any nuclear explosions conducted anywhere on Earth. For the verification of CTBT, several techniques are implemented. Radionuclide monitoring is of particular importance since it is the only method which can provide absolute assurance that a nuclear detonation has occurred

2010-10-01

347

Lyme myocarditis diagnosed by indium-111-antimyosin antibody scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

We report a new case of Lyme disease with cardiac manifestations, which has been possible to follow during the long period of 12 years. We have detected the usual ECG abnormalities, and concentric hypertrophic myocardiopathy, by echocardiography. The acute myocarditis was demonstrated by /sup 111/In-antimyosin scintigraphy, which showed global myocardial uptake of the tracer, constituting the first report, to our knowledge, of Lyme myocarditis diagnosed by this method.

1989-06-01

348

Long-range correlation analysis of earthquake-related geochemical variations recorded in Central Italy  

Energy Technology Data Exchange (ETDEWEB)

The long-range correlation properties in the hourly time variability of geochemical signals measured in a 70 m depth well at Triponzo (Umbria region), are investigated by the detrended fluctuation analysis (DFA). DFA is a data processing method that allows for the detection of scaling behaviors in observational time series even in the presence of non-stationarities. The procedure adopted has allowed for the unambiguous identification of possible correlations among the recorded signals and local earthquakes.

2004-07-01

349

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

Energy Technology Data Exchange (ETDEWEB)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out.

1983-01-01

350

Identification and determination of elements in Taraxacum officinale plant from different Bratislava localities  

International Nuclear Information System (INIS)

Elements Ti, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb and Sr were determined by the method of radionuclide X-ray fluorescence analysis with semiconductor detection in samples of Taraxacum officinale from various localities of Bratislava. The dependence of their content on the source and the degree of the air pollution was found out. (author).

1983-01-01

351

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

352

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

353

Gene rearrangement and radiation carcinogenesis  

International Nuclear Information System (INIS)

The development of leukemia and thyroid cancer is characterized by activation of the abl oncogene and ret oncogene, respectively. In order to clarify the relationship between these gene aberrations and radiation, the pro-myelogenous leukemia-derived cell line HL60 and the thyroid cancer-derived cell line 8505C, were irradiated in vitro with 100Gy of X-rays. RNA was then extracted from 10"8 cells of the respective cell lines and examined by the reverse transcription PCR method for rearrangements of abl and ret genes. Five kinds of positive bands were observed in the HL-60 cells irradiated with 100Gy of X-ray. Similarly, six positive bands were also observed in the 8505C cells irradiated with 100Gy. In vitro X-irradiation activation of oncogenes found in radiation induced cancers imply that gene rearrangement by X-rays is involved in the development of malignant tumors. Furthermore, in an experiment to detect radiation effects in A-bomb ...

1993-11-01

354

Determination of [sup 99]Tc in sea water at ultra low levels  

Energy Technology Data Exchange (ETDEWEB)

A method based on the collection of [sup 99]Tc from 500 l sea water samples by anion exchange and further extraction of TcO[sub 4][sup -] into 5% triisooctylamine-xylene has been improved to include a decontamination factor 6.5x10[sup 5] for uranium. The detection limit for [sup 99]Tc is thereby reduced to 3 mBq/m[sup 3].

1994-01-20

355

Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 Nucleic Acid Extraction Systems for Detection of RNA and DNA Respiratory Viruses in Nasopharyngeal Aspirate Samples?  

UK PubMed Central (United Kingdom)

The NucliSens easyMAG and BioRot 9604 automated nucleic acid extraction systems were evaluated and compared with the manual QIAamp (Qiagen) extraction method for their abilities to extract nucleic acid...Full Text Available

2008-07-01

356

Clinical translation of ultraviolet autofluorescence microscopy towards endomicroscopy for early detection of cancer  

Science.gov (United States)

The non-invasiveness of autofluorescence technology may reduce sampling error and time delay for histopathology diagnosis. We establish biophotonic methods and guidelines to visualize and interpret early epithelial tissue changes that signify disease. Flexible and rigid fiber endomicroscopy instrumentation design parameters feasible for translation towards clinical use are in development.

2010-12-01

357

Analysis of TL glow curves in differently doped LiF:Mg,Ti  

International Nuclear Information System (INIS)

A computerised curve-fitting method was developed to calculate the trapping parameters in LiF TLD-100 and LiF:Mg, Ti. After irradiation in a "6"0Co field and with X rays emitted at different voltages the TL process is best described by first-order kinetics. A dependence of the trapping parameters on both the concentration of Mg and Ti and photon energy was detected. (author).

358

Wind turbine fault diagnosis based on Morlet wavelet transformation and Wigner-Ville distribution  

British Library Electronic Table of Contents (United Kingdom)

Based on the Morlet wavelet transformation and Wigner-Ville distribution (WVD), we present a wind turbine fault diagnosis method in this paper. Wind turbine can be damaged by moisture absorption, fatigue, wind gusts or lightening strikes. Due to this reason, there is an increasing need to monitor the health of these structures. Vibration analysis is the best-known technology applied in wind turbine condition monitoring, in which the time-frequency analysis techniques such as Wigner-Ville distribution (WVD) are widely used. Theoretically WVD has an infinite resolution in time-frequency domain. For early wind turbine fault signals, however, there are two main difficulties in WVD analysis. One is strong noise signals in the background and the other is cross terms in WVD itself. In this paper,...

2010-01-01

359

Submitochondrial distribution of cAMP in its incubation with rat liver mitochondria  

Energy Technology Data Exchange (ETDEWEB)

When labeled cAMP is incubated with isolated mitochondria from rat liver, it penetrates not only through the outer membrane of the mitochondria but also into the mitoplasts, where it is accumulated chiefly in the matrix. Damage to the mitochondrial membrane by freezing-thawing promotes not an influx but an efflux of cAMP out of the mitoplasts. A substantial part of the labeled nucleotide in all the investigated submitochondrial fractions was identified as intact cAMP by the method of thin-layer chromatography. The transport of cAMP into the mitochondria can explain the activation of their functions by the hormones that activate cytoplasmic adenylate cyclase and by extramitochondrial (cytosol) cAMP, as well as the presence of cAMP-dependent protein kinase and cAMP-phosphodiesterase in the mitochondria.

1986-03-20

360

Seismic evaluation and upgrading of critical tower pile foundations in liquefiable soils  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro has been assessing and upgrading its facilities and implementing response alternatives to potential damage resulting from a major earthquake. This paper reviews the utility`s seismic evaluation of its overhead transmission system, focusing on the Lower Mainland area where most of the tall critical river-crossing towers are located. The paper gives an overview of the geologic environment of the Lower Mainland and outlines the criteria used for assessing existing structures for their ability to withstand design seismic loads. It then describes the investigation and analysis methods used in the assessment, including geotechnical field tests, ground response analysis, determination of soil liquefaction potential, and dynamic analysis of structures and piles. Options for seismic upgrades are discussed and illustrated by the case of the Pitt River crossing, where tower foundations were reinforced with steel pipe piles.

1995-12-31

361

Revenue management: the impact on business-to-business relationships  

British Library Electronic Table of Contents (United Kingdom)

Purpose - This paper aims to explore the links between revenue management and business-to-business (B2B) relationships and explains how revenue management can both support and damage B2B relationships. Design/methodology/approach - A single case study method was employed to conduct qualitative research into a company and its key accounts. In-depth data were collected from three divergent sources (company revenue managers, company account managers and nine of the company's key accounts) through semi-structured interviews, observations and document studies. Findings - The research findings reveal that from the company's perspective, managers acknowledge that revenue management has positively influenced the process of identifying and analysing key account activities and conducting contractual...

2009-01-01

362

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

363

Reliability-based design optimization of an FPSO riser support using moving least squares response surface meta-models  

British Library Electronic Table of Contents (United Kingdom)

The paper deals with the reliability-based design optimization (RBDO) of a riser support installed on a floating production storage and offloading (FPSO) unit under operation, extreme, damaged, and one line failure cases and installation loading conditions. The optimization problem is formulated such that probabilistic thickness variables described with random characteristics are determined by minimizing the weight of the riser support structure subjected to stress constraints for the given target reliability. The initial design model is generated based on actual FPSO riser support specifications. The finite element analysis is conducted using NASTRAN, and the probabilistic optimal solutions are obtained via the moving least squares method in the context of RBDO using a response surface me...

2011-01-01

364

Partial natural-gas firing of a cupola furnace. Delvis naturgasfyring af kupolovne; Litteraturstudie  

Energy Technology Data Exchange (ETDEWEB)

A survey was undertaken of literature on the conversion of coke-fired cupola furnaces so that they can be fuelled, either wholly or partially, with natural gas. The aim was to determine the most suitable method for a specific furnace. Substitution with natural gas can result in speedier adjustment and control of the smelting process and in addition operational costs are reduced as natural gas is a cheaper fuel. The payback period would be one year. Pollutive emissions would be reduced. It was concluded that the most satisfactory solution would be that 3-4 gas burners should be placed immediately above the smelting zone in the furnace. Each burner should be placed in a separate combustion box in which the complete combustion process could take place. The burners should be placed symmetrically about the furnace, pointing at a small degree downwards. In this way the combustion chamber will not be filled with materials from the furnace and the burners will not be ...

1992-12-01

365

Experimental characterisation and modelling of crack initiation and short crack propagation for fatigue life prediction of a #beta#-titanium alloy  

International Nuclear Information System (INIS)

Up to 90% of the life time of cyclically loaded components is determined by short crack initiation and propagation. This stage of the fatigue damage process is strongly influenced by microstructural features, e.g. grain boundaries and crystallographic grain orientation. Therefore LEFM can not be applied in a reasonable manner explaining the demand for a mechanism-related modelling method. The present study deals with mechanical testing and microstructural examinations applied to the relatively new #beta#-titanium alloy LCB. The results are used as data base to develop a new short crack model that is based on the model of Navarro and de los Rios. By using various techniques such as electron back-scattered diffraction and finite-element calculations the origin of crack initiation is revealed and the characteristics of crack propagation is determined. (orig.)

2000-02-24

366

Environmental effects and energy efficiency in building design: A green building approach. Part 2. Basic data for environmental effects. Research report  

Energy Technology Data Exchange (ETDEWEB)

The development of comfort in buildings throughout the centuries was influenced by the demand for progress, wealth and innovation in various respects. At present, it seems that progress may only be possible by taking into account the environment and creating methods of reducing further damage to the environment. The innovative feature of future progress my be reducing the impact on the environment from human and building activities by using appropriate technology. As it is impossible to build without any impact on the environment and this is likely to be so in the future, the objective is and will be to find solutions for buildings which are more compatible with the environment. The objective is to demonstrate that it is viable to design buildings with minimized impact on the environment, while still maintaining appropriate comfort levels.

1993-01-01

367

De-icing technologies: Introduction to Manitoba Hydro's use of ice melting and ice rolling technologies to remove ice from subtransmission and 115 kV transmission lines  

International Nuclear Information System (INIS)

Manitoba Hydro's Ice Storm Management Program to reduce ice damage to overhead power lines in the voltage range of 8 kV to 115 kV is described. Overhead power lines are de-iced either by AC ice melting, which involves placing a three-phase short at a calculated point, or ice rolling, which is a process of mechanically stripping ice from conductors. Direct current heating and underground distribution systems are also accepted prevention measures. Advantages and disadvantages of each of these methods of de-icing are reviewed. Material for this paper has been extracted from a workshop manual prepared for the 1993 and 1998 Ice Storm Management workshops organized by Manitoba Hydro through the Canadian Electrical Association. 1 ref.

1999-03-29

368

Biological pest control  

Energy Technology Data Exchange (ETDEWEB)

For the purposes of energy forests, biological pest control should be interpreted as any method of using natural organisms or their products for the regulation of herbivores, below the economic threshold. The organisms include the energy forest crop species and natural enemies of pest herbivores. Examples are provided of three-trophic-level interactions, including some on willows and poplars. Bottom-up effects may be particularly strong in juvenile Salicaceae, which are used in energy forest production, because plants are growing vigorously, and many herbivores respond positively. Some major pests on willows and poplars appear to have weak top-down regulation, and they may be influenced most by bottom-up effects such as plant resistance through genetic variation, ontogenetic aging and physiological aging. Balancing the bottom-up and top-down forces in energy forests may be difficult in short-rotation crops, but harvesting may prove to be important as a control ...

1994-01-01

369

Behaviour of the steam generators in the Belgian nuclear power plants  

International Nuclear Information System (INIS)

After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).

1986-04-15

370

A study on the transient piping vibration of power plant. Secondary piping system of Wolsung 1 unit  

Energy Technology Data Exchange (ETDEWEB)

In order to maintain a safe operation and availability of generating facilities, qualitative and quantitative assessment of piping vibration was performed vibration sources and damages of piping support was identified on the second piping system of Wolsung nuclear power plant unit 1 .Inspected piping supports and structures in both hot and cold condition .Established evaluation procedures of piping vibration .Performed the static analysis of 2 nd piping system .Established optimal vibration reducing method .The measured vibration level after installing rigid supports and energy absorbing type restraint was reduced about 7 times in velocity unit (author). 24 refs., 95 figs.

1996-08-01

371

Using the in situ lift-out technique to prepare TEM specimens on a single-beam FIB instrument  

International Nuclear Information System (INIS)

Transmission electron microscope (TEM) specimens are today routinely prepared using focussed ion beam (FIB) instruments. Specifically, the lift-out method has become an increasingly popular technique and involves removing thin cross-sections from site-specific locations and transferring them to a TEM grid. This lift-out process can either be performed ex situ or in situ. The latter is mainly carried out on combined dual-beam FIB and scanning electron microscope (SEM) systems whereas conventional single-beam instruments often are limited to the traditional ex situ method. It is nevertheless desirable to enhance the capabilities of existing single-beam instruments to allow for in situ lift-out preparation to be performed since this technique offers a number of advantages over the older ex situ method. A single-beam FIB instrument was therefore modified to incorporate an in situ micromanipulator fitted with a tungsten needle, ...

2008-08-01

372

Numerical flow simulation in ship and ocean engineering; Senpaku kaiyo suiri bun`ta deno ryutai suchi simulation  

Energy Technology Data Exchange (ETDEWEB)

The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against and damaged the tank ...

1995-01-01

376

Incidents of major damage to steam turbines  

International Nuclear Information System (INIS)

The author furnishes a review of incidents of major damage to high-output steam turbines. At the same time, he thereby underlines the call for an improvement in the exchange of experience on such damage and its causes at international level. Only the careful observance of past damage experience - including that of foreign manufacturers and operators - complete and modern monitoring equipment and the painstaking evaluation of all data furnished by such equipment can keep the risk of new technical development within economically tolerable limits. (orig.).

386

On-line measurement and inspection technologies of surface properties of steel sheets; Koban hyomen hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In steel production lines such as pickling lines, cold rolling mills and coil processing lines, the needs for on-line continuous measurement of surface quality and property of products and on-line inspection of surface defects have become strong. This is because user requirements for the surface quality of various products have become severer than before and besides, expectations are running high on the side of manufacturers for higher speeds of production lines and higher quality by the adoption of automatic inspection. As for the measurement of surface quality, continuous measurements along the full length of a steel strip are required in order to overcome problems derived from off-line, batch measurements that cannot satisfy user's demands for quality assurance. As for surface defects detection, various kinds of methods have been practically applied to production lines. However, it is the matter of fact that performances of these ...

1999-12-01

387

Station set residual : event classification using historical distribution of observing stations.  

Science.gov (United States)

Analysts working at the International Data Centre in support of treaty monitoring through the Comprehensive Nuclear-Test-Ban Treaty Organization spend a significant amount of time reviewing hypothesized seismic events produced by an automatic processing system. When reviewing these events to determine their legitimacy, analysts take a variety of approaches that rely heavily on training and past experience. One method used by analysts to gauge the validity of an event involves examining the set of stations involved in the detection of an event. In particular, leveraging past experience, an analyst can say that an event located in a certain part of the world is expected to be detected by Stations A, B, and C. Implicit in this statement is that such an event would usually not be detected by Stations X, Y, or Z. For some well understood parts of the world, the absence of one or more ...

2010-04-01

388

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-08-01

389

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-01-01

390

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best possible adaptation ...

2006-12-21

391

The use of molecular biology techniques for the diagnosis and epidemiological study of foot-and-mouth disease virus in Thailand  

International Nuclear Information System (INIS)

The detection of foot-and-mouth disease (FMD) virus from various kinds of field samples (tissue extract and cell culture isolate) was studied using the polymerase chain reaction (PCR) technique. The gene selected for diagnosis was the polymerase gene and an amplification target product of 454 bp in length was produced using AP5/AP6 primer sets. The PCR product was further examined by NcoI endonuclease digestion. The presence of the internal restriction site was confirmed by demonstration of two small fragments of 330 bp and 124 bp in length. Forty-nine samples that gave positive and negative results by ELISA typing and were positive by the PCR test were tested by NcoI digestion to confirm the results. About 10% of PCR products could not be confirmed by the method. Furthermore the FMD RNA polymerase gene could be detected by the PCR method in samples negative in both ELISA typing and the virus isolation ...

2000-05-01

392

The use of combustible metals in explosive incendiary devices  

Energy Technology Data Exchange (ETDEWEB)

We have investigated tailoring damage effects of explosive devices by addition of unconventional materials, specifically combustible metals. Initial small-scale as well as full-scale testing has been performed. The explosives functioned to disperse and ignite these materials. Incendiary, enhanced-blast, and fragment-damage effect have been identified. These types of effects can be used to extend the damage done to hardened facilities. In other cases it is desirable to disable the target with minimal collateral damage. Use of unconventional materials allows the capability to tailor the damage and effects of explosive devices for these and other applications. Current work includes testing of an incendiary warhead for a penetrator.

1996-08-01

393

Genotoxic damage in polychaetes: A study of species and cell-type sensitivities  

British Library Electronic Table of Contents (United Kingdom)

The marine environment is becoming increasingly contaminated by environmental pollutants with the potential to damage DNA, with marine sediments acting as a sink for many of these contaminants. Understanding genotoxic responses in sediment-dwelling marine organisms, such as polychaetes, is therefore of increasing importance. This study is an exploration of species-specific and cell-specific differences in cell sensitivities to DNA-damaging agents in polychaete worms, aimed at increasing fundamental knowledge of their responses to genotoxic damage. The sensitivities of coelomocytes from three polychaetes species of high ecological relevance, i.e. the lugworm Arenicola marina, the harbour ragworm Nereis diversicolor and the king ragworm Nereis virens to genotoxic damage are compared, and dif...

2008-01-01

394

Damage to rotor blades in axial steam turbines  

International Nuclear Information System (INIS)

A statistical evaluation of rotor blade damage in axial steam turbines affords an insight into the extent of the repair costs incurred and reveals the types of defects and shortcomings which cause such damage. The great amount of rotor blade damage discovered during control inspections will surprise even many turbine experts. The statistical evaluation is followed by a review of the more frequent causes of damage and their characteristic features, illustrated on the basis of practical examples. This contribution is intended as an aid to both the manufacturers and operators of steam turbines in preventing the oft almost classic types of faults which constantly recur. (orig.).

395

Effects of Multi-ion Irradiation on Microstructural Changes in Lithium Titanate  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Li{sub 2}TiO{sub 3} is regarded as one of the most suitable candidates for the solid tritium breeder material of D-T fusion reactors. It is known that, in an operating fusion reactor, the radiation damage in Li{sub 2}TiO{sub 3} will be caused by fast neutrons, energetic tritons and helium ions generated in {sup 6}Li(n,{alpha}){sup 3}H reaction. The irradiation damage caused by such radiation may result in the microstructural changes, and the changes may affect the characteristics of Li{sub 2}TiO{sub 3} such as tritium release behavior. Thus the study of irradiation defects and microstructural changes caused by irradiation in Li{sub 2}TiO{sub 3} is essential to evaluate its irradiation performance. Simulation of the fusion reactor environment and hence the study of a synergistic effect of atomic displacement damage in Li{sub 2}TiO{sub 3} are approached by a simultaneous irradiation with ...

2007-07-01

396

Current Status on Stress Diagnostic Kit and Detection Technology  

Energy Technology Data Exchange (ETDEWEB)

The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases ...

2008-06-15

397

The map equation  

CERN Document Server

Many real-world networks are so large that we must simplify their structure before we can extract useful information about the systems they represent. As the tools for doing these simplifications proliferate within the network literature, researchers would benefit from some guidelines about which of the so-called community detection algorithms are most appropriate for the structures they are studying and the questions they are asking. Here we show that different methods highlight different aspects of a network's structure and that the the sort of information that we seek to extract about the system must guide us in our decision. For example, many community detection algorithms, including the popular modularity maximization approach, infer module assignments from an underlying model of the network formation process. However, we are not always as interested in how a system's network structure was formed, as we are in how a ...

2009-01-01

398

The Galactic Exoplanet Survey Telescope (GEST)  

CERN Document Server

The Galactic Exoplanet Survey Telescope (GEST) will observe a 2 square degree field in the Galactic bulge to search for extra-solar planets using a gravitational lensing technique. This gravitational lensing technique is the only method employing currently available technology that can detect Earth-mass planets at high signal-to-noise, and can measure the frequency of terrestrial planets as a function of Galactic position. GEST's sensitivity extends down to the mass of Mars, and it can detect hundreds of terrestrial planets with semi-major axes ranging from 0.7 AU to infinity. GEST will be the first truly comprehensive survey of the Galaxy for planets like those in our own Solar System.

2002-01-01

399

Rocky Mountain spotted fever in areas of high and low prevalence: survey for canine antibodies to spotted fever rickettsiae.  

Science.gov (United States)

Antibodies to Rickettsia rickettsii were detected by indirect immunofluorescence in sera from 149 of 467 dogs (32%) examined from 4 military installations located in Kentucky, North Carolina, Pennsylvania, and Virginia. The prevalence at individual installations ranged from 4.3% at Fort Knox, Ky, to 63.4% at Fort Bragg, NC. Most of the seropositive dogs were in the working and sporting groups of dogs. The difference in antibody prevalence between sexes was not significant. Serologic responses were related to R rickettsii infection, although antibodies to R montana also were detected in a few of the sera. Comparison of serodiagnostic methods indicated that the indirect fluorescent antibody test was more sensitive than was the indirect hemagglutination test for obtaining survey data on the prevalence of Rocky Mountain spotted fever in the area. PMID:6808878

1982-08-01

400

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

401

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

402

Properties of different eddy-current probes for steam generator tube testing  

Energy Technology Data Exchange (ETDEWEB)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection.

1981-01-01

403

Properties of different eddy-current probes for steam generator tube testing  

International Nuclear Information System (INIS)

With steam generator check testing, the numerous types of defect not only have to be detected reliably but also to be identified correctly and classified according to depth. A priori, no signals are provided by the physical eddy-current mechanism, i.e. the disturbance of an excited eddy-current field by a defect, which will allow unambiguous identification and classification of the defects. The task, therefore, consists in designing the eddy-current method in terms of measurement technology in such a way as to obtain useful detection, identification and classification by a translation of the signals as simple and as save as possible. Internal through-flow wils and internal rotating probes were examined for their suitability to fulfill this three-pronged task with steam generator inspection. (orig./RW).

1981-01-01

404

Progress Report Towards the ICANOE Detector  

CERN Document Server

We present a proposal for a combined ICARUS & NOE general purpose detector, to be installed in Hall B of the Gran Sasso Laboratory.The main scientific goal is the one of elucidating in a comprehensive way the pattern of neutrino $9 masses and mixings, following both (1) the S-KAM results and (2) the predictions on atmospheric neutrinos of the large solution of the Solar Neutrinos deficit. To achieve these goals, the experimental method is based upon the $9 complementary and simultaneous detection of CERN beam (CNGS) and cosmic ray (CR) events. This is made possible because of the complete isotropy of the detection technique. For the currently allowed values of the S-KAM results, both $9 CNGS and cosmic ray data will give independent measurements and provide a precise $(sin^{2}2\\theta; \\Delta m^{2})$ determination rather than a wide band of allowed values. Since we can observe and unambiguously identify $9 $\

1999-01-01

405

Monoclonal antibodies: new agents for cancer detection and targeted therapy  

International Nuclear Information System (INIS)

Antibodies directed against markers on cancer cells are gaining in importance for the purpose of targeting diagnostic and therapeutic agents. In the past, this approach has had very limited success principally because the classical methods for producing antibodies from blood serum of animals immunized with cancer cells or extracts were unsatisfactory. The situation has changed dramatically since 1975 following the design of procedures for 'immortalizing' antibody-producing cells (lymphocytes) by fusing them with cultured myeloma cells to form hybridomas which continuously secrete antibodies. Since these hybridomas produce antibodies coded for by a single antibody-producing cell, the antibodies are called monoclonal. Building on these advances in biomedical research, it is now possible to reproducibly manufacture monoclonal antibodies on a scale suitable for use in cancer detection and therapy.

406

Microdialysis unit for molecular weight separation  

Energy Technology Data Exchange (ETDEWEB)

The present invention relates generally to an apparatus and method for separating high molecular weight molecules from low molecular weight molecules. More specifically, the invention relates to the use of microdialysis for removal of the salt (low molecular weight molecules) from a nucleotide sample (high molecular weight molecules) for ESI-MS analysis. The dialysis or separation performance of the present invention is improved by (1) increasing dialysis temperature thereby increasing desalting efficiency and improving spectrum quality; (2) adding piperidine and imidazole to the dialysis buffer solution and reducing charge states and further increasing detection sensitivity for DNA; (3) using low concentrations of dialysis buffer and shifting the DNA negative ions to higher charge states, producing a nearly 10-fold increase in detection sensitivity and a slightly decreased desalting efficiency, or (4) any combination of ...

1999-09-21

407

In vivo chicken model for peripheral intravascular human fibrin clot detection  

Energy Technology Data Exchange (ETDEWEB)

A chicken model was prepared that provides a simple and economical method of evaluating the use of fibrin-specific monoclonal antibody 64C5 in the detection of peripheral vascular thrombi. Human fibrin was clotted in segments of a chicken's femoral artery and vein prior to intravenous injection of radioiodinated antibody 64C5. After a 3-hr perfusion time, the thrombosed and contralateral control segments of the vessels were excised and counted for radioactivity. The radiolabeled 64C5 uptake ratio of the thrombosed segment to the control segment was 5.4 +/- 1.2 (p less than 0.007) in the femoral artery, and 3.8 +/- 1.1 (p less than 0.02) in the femoral vein. This in vivo chicken model may also find application in studies of targeting agents for human fibrin.

1988-08-01

408

Field results using measurement-while-drilling directional systems in Long Beach, California  

Energy Technology Data Exchange (ETDEWEB)

One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.

1981-01-01

409

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be considered in the appropriate selection of a device. (author)

410

Estimating personal costs incurred by a woman participating in mammography screening in the National Breast and Cervical Cancer Early Detection Program  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND.The National Breast and Cervical Cancer Early Detection Program (NBCCEDP) covers the direct clinical costs of breast and cervical cancer screening and diagnostic follow-up for medically underserved, low-income women. Personal costs are not covered. In this report, the authors estimated personal costs per woman participating in NBCCEDP mammography screening by race/ethnicity and also estimated lifetime personal costs (ages 50-74 years).METHODS.A decision analysis model was constructed and parameterized by using empiric data from a retrospective cohort survey of mammography rescreening among women ages 50 years to 64 years who participated in the NBCCEDP. Data from 1870 women were collected from 1999 to 2000. The model simulated the flow of resources incurred by a woman participat...

2008-01-01

411

Eddy current probe development based on a magnetic sensor array; Developpement d'un imageur magnetique pour le controle non destructif par courants de Foucault  

Energy Technology Data Exchange (ETDEWEB)

This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications.

2007-06-15

412

Detection of previous neutron irradiation and reprocessing of uranium materials for nuclear forensic purposes  

International Nuclear Information System (INIS)

The paper describes novel analytical methods developed for the detection of previous neutron irradiation and reprocessing of illicit nuclear materials, which is an important characteristic of nuclear materials of unknown origin in nuclear forensics. Alpha spectrometry and inductively coupled plasma sector-field mass spectrometry (ICP-SFMS) using solution nebulization and direct, quasi-non-destructive laser ablation as sample introduction were applied for the measurement of trace-level "2"3"2U, "2"3"6U and plutonium isotopes deriving from previous neutron irradiation of uranium-containing nuclear materials. The measured radionuclides and isotope ratios give important information on the raw material used for fuel production and enable confirm the supposed provenance of illicit nuclear material.

2009-04-01

413

Detection of Visual Deficits in Aging DBA/2J Mice by Two Behavioral Assays  

British Library Electronic Table of Contents (United Kingdom)

Purpose: The DBA/2J mice have been used as an animal model for human pigmentary glaucoma. However, these mice develop various degrees of disease symptoms at different ages, making it difficult to detect pathological changes of retinal degeneration at glaucoma onset. The purpose of this study is to develop a non-invasive assay to identify individual mice that develop visual deficits. Materials and Methods: We apply two behavioral tests, a swimming test of visual discrimination and a test of optomotor response, to identify glaucomatous DBA/2J mice. We then examine whether the elevation of intraocular pressure (IOP), the common risk factor for glaucoma, affects visual performances of the DBA/2J mice. We further compare the retinal ganglion cell death, one of the signature glaucoma symptoms, i...

2011-01-01

414

Cryo-irradiation as a terminal method for the sterilization of drug aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study is to evaluate the specificities of the irradiation of drugs in frozen aqueous solution. The structures of the degradation products were determined to gain insight into the radiolysis mechanisms occurring in frozen aqueous solutions. Metoclopramide hydrochloride and metoprolol tartrate were chosen as models. The frozen solutions were irradiated at dry ice temperature by high energy electrons at various doses. The drug purity (chemical potency) and the radiolysis products were quantified by HPLC-DAD. Characterization of the degradation products was performed by LC-APCI-MS-MS. The structures of the radiolysis products detected in irradiated frozen aqueous solutions were compared to those detected in solid-state and aqueous solutions (previous studies). For both metoclop...

2008-01-01

415

Coupling of magnetostriction and electrostriction in the porous rheological composite  

Energy Technology Data Exchange (ETDEWEB)

The production method of the elastic composite containing ferrous particles and titanium barium particles dispersed in the porous silicone matrix is described in this article. Since it contains ferrous and titanium barium particles, this composite shows magnetorheological and also electrorheological properties. The electrostriction of composite samples in the electric field with maximal intensity 1.5x10{sup 6} V/m was investigated. The magnetostriction in the magnetic field with maximal induction 1 T was also investigated. It was found that samples elongate with increased electric field intensity, and the magnetic field induction was detected. By increasing the samples' elongation with increase of ferrous particles, titanium barium particles and pores number were also detected. In the investigated division of the electric and magnetic field the elongation changed in a linear way. The maximal elongation achieved was ...

2008-08-15

416

Cosmic ray antiproton/electron discrimination capability of the CAPRICE silicon-tungsten calorimeter using neural networks  

Energy Technology Data Exchange (ETDEWEB)

A data analysis based on an artificial neural network classifier is proposed to identify cosmic ray antiprotons detected with the CAPRICE silicon-tungsten imaging calorimeter against electron background in the energy range 1.2-4.0 GeV. A set of new physical variables, describing the events inside the calorimeter on the base of their different patterns, are introduced in order to discriminate between hadronic and electromagnetic showers. The ability of the artificial neural network classifier to perform a careful multidimensional analysis gives the possibility to identify antiprotons with an electron rejection 408{+-}85 (stat) at 95.0{+-}0.2 (stat)% of signal detection efficiency. The high accuracy achieved by this method improves substantially the efficiency in the evaluation of the cosmic ray antiproton spectrum. (orig.).

1996-11-01

417

Catalyst and method for reduction of nitrogen oxides  

Energy Technology Data Exchange (ETDEWEB)

A Selective Catalytic Reduction (SCR) catalyst was prepared by slurry coating ZSM-5 zeolite onto a cordierite monolith, then subliming an iron salt onto the zeolite, calcining the monolith, and then dipping the monolith either into an aqueous solution of manganese nitrate and cerium nitrate and then calcining, or by similar treatment with separate solutions of manganese nitrate and cerium nitrate. The supported catalyst containing iron, manganese, and cerium showed 80 percent conversion at 113 degrees Celsius of a feed gas containing nitrogen oxides having 4 parts NO to one part NO.sub.2, about one equivalent ammonia, and excess oxygen; conversion improved to 94 percent at 147 degrees Celsius. N.sub.2O was not detected (detection limit: 0.6 percent N.sub.2O).

2008-08-19

418

Catalyst and method for reduction of nitrogen oxides  

Energy Technology Data Exchange (ETDEWEB)

A Selective Catalytic Reduction (SCR) catalyst was prepared by slurry coating ZSM-5 zeolite onto a cordierite monolith, then subliming an iron salt onto the zeolite, calcining the monolith, and then dipping the monolith either into an aqueous solution of manganese nitrate and cerium nitrate and then calcining, or by similar treatment with separate solutions of manganese nitrate and cerium nitrate. The supported catalyst containing iron, manganese, and cerium showed 80 percent conversion at 113 degrees Celsius of a feed gas containing nitrogen oxides having 4 parts NO to one part NO.sub.2, about one equivalent ammonia, and excess oxygen; conversion improved to 94 percent at 147 degrees Celsius. N.sub.2O was not detected (detection limit: 0.6 percent N.sub.2O).

2008-05-27

419

Authentication of byte sequences  

Energy Technology Data Exchange (ETDEWEB)

Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.

1991-06-01

420

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery ...

2006-08-25

421

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. (author)

422

Effective multiplication factor measurement by feynman-{alpha} method. 3  

Energy Technology Data Exchange (ETDEWEB)

The sub-criticality monitoring system has been developed for criticality safety control in nuclear fuel handling plants. In the past experiments performed with the Deuterium Critical Assembly (DCA), it was confirmed that the detection of sub-criticality was possible to k{sub eff} = 0.3. To investigate the applicability of the method to more generalized system, experiments were performed in the light-water-moderated system of the modified DCA core. From these experiments, it was confirmed that the prompt decay constant ({alpha}), which was a index of the sub-criticality, was detected between k{sub eff} = 0.623 and k{sub eff} = 0.870 and the difference of 0.05 - 0.1{Delta}k could be distinguished. The {alpha} values were numerically calculated with 2D transport code TWODANT and monte carlo code KENO V.a, and the results were compared with the measured values. The differences between calculated and measured values were proved ...

1998-06-01

423

Determination of low level sulfides in environmental waters by automated gas dialysis/methylene blue colorimetry  

Energy Technology Data Exchange (ETDEWEB)

A sensitive and rapid automated method has been developed for the selective analysis of acid extractable sulfide in environmental samples by combining gas dialysis separation techniques with methylene blue detection procedures. Acid extractable sulfide is separated from the sample matrix by the gas dialysis membrane and subsequently trapped in a dilute sodium hydroxide receiving stream. This stream is reacted with N,N-dimethyl-p-phenylenediamine and ferric chloride to produce methylene blue which is then quantitated colorimetrically at 660 nm. For standards and nonturbid environmental samples, there is good agreement between the results obtained by this procedure and the standard methylene blue method. The effect of interferences on the accurate determination of sulfide by both methods was also examined and it was found that cupric ions significantly interfered with sulfide estimation. To obtain ...

1990-01-01

424

Analysis of pesticides in dried hops by liquid chromatography-tandem mass spectrometry.  

Science.gov (United States)

An analytical method was developed for the determination of eleven agrochemicals [abamectin (as B1a), bifenazate, bifenthrin, carfentrazone-ethyl, cymoxanil, hexythiazox, imidacloprid, mefenoxam, pymetrozine, quinoxyfen, and trifloxystrobin] in dried hops. The method utilized polymeric and NH2 solid phase extraction (SPE) column cleanups and liquid chromatography with mass spectrometry (LC-MS/MS). Method validation and concurrent recoveries from untreated dried hops ranged from 71 to 126% for all compounds over three levels of fortification (0.10, 1.0, and 10.0 ppm). Commercially grown hop samples collected from several field sites had detectable residues of bifenazate, bifenthrin, hexythiazox, and quinoxyfen. The control sample used was free of contamination below the 0.050 ppm level for all agrochemicals of interest. The limit of quantitation and limit of detection for all ...

2008-07-02

425

The Sorcerer II Global Ocean Sampling Expedition: Expanding theUniverse of Protein Families  

Energy Technology Data Exchange (ETDEWEB)

Metagenomics projects based on shotgun sequencing of populations of micro-organisms yield insight into protein families. We used sequence similarity clustering to explore proteins with a comprehensive dataset consisting of sequences from available databases together with 6.12 million proteins predicted from an assembly of 7.7 million Global Ocean Sampling (GOS) sequences. The GOS dataset covers nearly all known prokaryotic protein families. A total of 3,995 medium- and large-sized clusters consisting of only GOS sequences are identified, out of which 1,700 have no detectable homology to known families. The GOS-only clusters contain a higher than expected proportion of sequences of viral origin, thus reflecting a poor sampling of viral diversity until now. Protein domain distributions in the GOS dataset and current protein databases show distinct biases. Several protein domains that were previously categorized as kingdom specific are shown to have GOS examples in ...

2006-03-23

426

Synthesis of Si nanowires for MEMS cantilever sensor applications  

Science.gov (United States)

We present a new approach for growing Si nanowires directly from a silicon substrate, without the use of a metal catalyst, silicon vapor or CVD gasses. The growth can be performed in a furnace type configuration at moderate temperatures or in localized regions by resistive heating. Since the silicon wires grow directly from the silicon substrate, they do not need to be manipulated nor aligned for subsequent applications. Wires in the 20-50 nm diameter range with lengths over 80 ?m can be grown by this technique. We have studied the effects of various growth parameters, including temperature, substrate orientation, initial sample cleaning and carrier gasses. Results indicate that most important parameters in the growth of the nanowires are the surface cleaning, the temperature and the type of carrier gas used. A model is proposed, which involves an oxide catalyst for the process, with the growth of the nanowires enabled by a significantly enhanced silicon surface diffusion process, due ...

2004-12-01

427

The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)  

International Nuclear Information System (INIS)

The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole ...

2009-04-15

428

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the ...

429

A liquid chromatography?fluorimetric method for the in vitro estimation of the skin penetration of disodium phenyldibenzimidazole tetrasulfonate from sunscreen formulations through human skin  

British Library Electronic Table of Contents (United Kingdom)

Disodium phenyldibenzimidazole tetrasulfonate (PDT) is a new organic UV filter with hydrophilic properties used in modern sunscreen spray formulations. The aim of this work was to develop and validate an analytical method that can be used to study skin absorption of PDT from sunscreens. Results obtained in vitro for human skin showed a low level of absorption. The proposed in vitro method employs a diffusion cell. Sunscreen lotion was applied onto pretreated human skin, which was then placed in the cell. PDT was collected in a receptor liquid, the surface of which was in contact with the skin. The solutions obtained were diluted appropriately and analyzed by liquid chromatography without any interference. The analytical features of chromatographic determination with fluorimetic detection w...

2006-01-01

430

Limitations of traveling wave relaying for overhead EHV transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Limitations of traveling wave relaying schemes for protection of overhead extra-high voltage transmission lines are investigated. A method of analysis of traveling wave phenomena for three phase transmission lines is developed in which the interdependent phase voltages and currents are decoupled into their modal counterparts, which are approximately independent. A time domain digital simulation program is used to solve the modal transmission line equations to obtain the fault induced traveling waves detected at the relay location. The frequency dependence of the aerial modes is ignored but their losses are included. A lumped element analysis method, originally developed for transient analysis of lossy coaxial cables, is adapted here to obtain approximate solution for the fault induced traveling waves of the ground mode. Excellent agreement is found between the results obtained by this method and ...

1986-01-01

431

Ultrasensitive fluorescence detection of DNA  

Science.gov (United States)

Progress on Ultrasensitive fluorescence detection of DNA is briefly described. (CBS)

1991-01-01

432

Fluorescent Silicate Materials for the Detection of Paraoxon  

Science.gov (United States)

... significantly lower limits of detection. The complex fluorescence spectra of these constructs indicated that only a portion ...

2010-03-19

433

Thermal modelling of underground coal fires in Northern China  

Energy Technology Data Exchange (ETDEWEB)

The thesis describes work undertaken as part of a larger remote sensing based project which aims to detect, measure and monitor coal fires in two test areas in northern China. The first main topic addressed in this thesis is the detection of fires using several different thermal remote sensing data sets. The synergistic use of the different data sets is emphasised. The second major part of the thesis deals with thermal modelling of the coal fires. Three different models are developed, which allow a fire's depth, temperature, extent, total heat output and rate of movement to be determined. The models are tested both in the laboratory and using various field data sets. A model based on the assumption that the fire is a point heat source and that the temperature distribution around it is spherically symmetrical is shown to be the most effective. A simpler, one-dimensional coal fire model and a model based on the finite element ...

1998-07-01

434

Tau Boo b: Hunting for reflected starlight  

CERN Document Server

Aims. We attempt to detect starlight reflected from the hot Jupiter orbiting the main-sequence star Tau Boo, in order to determine the albedo of the planetary atmosphere, the orbital inclination of the planetary system and the exact mass of the planetary companion. Methods. We analyze high-precision, high-resolution spectra, collected over two half nights using UVES at the VLT/UT2, by way of data synthesis. We interpret our data using two different atmospheric models for hot Jupiters. Results. Although a weak candidate signal appears near the most probable radial velocity amplitude, its statistical significance is insufficient for us to claim a detection. However, this feature agrees very well with a completely independently obtained result by another research group, which searched for reflected light from Tau Boo b. As a consequence of the non-detection of reflected light, we place upper limits to the ...

2010-01-01

435

State-of-the-art techniques for internal quality measurements in steel sheets production processes; Hakkoban seizo ni okeru naibu hinshitsu no onrain keisoku oyobi kensa gijutsu  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the state-of-the-art ultrasonic and magnetic measuring techniques developed at Kawasaki Steel and used in the production process of steel sheets are described. Representative examples shown here are as follows: (1) Magnetic flux leakage testing system for the detection of nonmetallic inclusions, (2) Nondestructive orientation measurement for secondary re-crystallized grains in grain-oriented electrical steel by ultrasonic interferometry, (3) Immersion testing method for the detection of nonmetallic inclusions, (4) Surface wave probe for the detection of surface flaws in rolls used in rolling mills. Developments of these techniques and their applications to actual steel sheets production processes have contributed to advance in technologies for quality assurance and control. With the help of these techniques, steel sheet products with advanced and uniform properties are being continuously ...

1999-12-01

436

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection  

Energy Technology Data Exchange (ETDEWEB)

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and corrected, such that a more ...

2009-11-23

437

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between tube plate holes, ultrasonic compression wave probes have been used. (U.K.).

1976-03-09

438

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...

1985-04-25

439

Detection of the heavy Higgs boson at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We consider the possibility of detecting a heavy Higgs boson (m_H>2m_Z) in proposed #gamma##gamma# colliders through the semileptonic mode #gamma##gamma##->#H#->#ZZ#->#q bar ql"+l-. We show that due to the nonmonochromatic nature of the photon beams produced by the laser-backscattering method, the resultant cross section for Higgs production is much smaller than the on-resonance cross section, and generally decreases with increasing collider energy. Although continuum ZZ production is expected to be negligible, we demonstrate the presence of, and calculate sizable backgrounds from, #gamma##gamma##->#l"+l-Z,q bar qZ, with Z#->#q bar q,l"+l-, respectively, and #gamma##gamma##->#t bar t#->#b bar bl"+l-#nu# bar #nu#. This channel may be used to detect a Higgs boson of mass m_H up to around 350 GeV at a 0.5 TeV e"+e- collider, assuming a nominal yearly luminosity of 10--20 fb"-"1.

440

Containment of genetically engineered organisms after application to subsurface environments. Technical completion report  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of containing genetically engineered bacteria with enhanced dehalogenating properties for in situ bioremediation was investigated. (1) An agarose matrix microbead protocol and a detection system for contained microorganisms or DNA were developed. Multiplex Polymerase Chain Reaction (PCR) allowed tracking of a consortium of encapsulated organisms or several gene targets from a single species. Gene sequences encoding the enzymes responsible for initiating the biodegradation of toluene, octane, and 2,4-D were detected by multiplex PCR and nucleic acid probes from similar to 1-10 biodegradative cells/g soil. Improved DNA extraction methods resulted in PCR reactions detecting similar to 6 cells/g soil. (2) The pcpB gene (for the broad-spectrum detoxicant pentachlorophenol (PCP) hydroxylase) isolated from Flavobacterium sp. strain ATCC 39723 was used in attempts to develop an improved ...

1993-06-01

441

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...

1987-12-01

442

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. ...

1987-01-01

443

Community Detection using a Measure of Global Influence  

CERN Document Server

The growing popularity of online social networks has provided researchers with access to large amount of social network data. This, coupled with the ever increasing computation speed, storage capacity and data mining capabilities, led to the renewal of interest in automatic community detection methods. Surprisingly, there is no universally accepted definition of the community. One frequently used definition states that ``communities, that have more and/or better-connected `internal edges' connecting members of the set than `cut edges' connecting the set to the rest of the world''[Leskovec et al. 20008]. This definition inspired the modularity-maximization class of community detection algorithms, which look for regions of the network that have higher than expected density of edges within them. We introduce an alternative definition which states that a community is composed of individuals who have more influence on others ...

2008-01-01

444

Coal mine fire inventory and monitoring in Jharia coalfield Bihar, India, using thematic mapper thermal IR data  

Energy Technology Data Exchange (ETDEWEB)

Largest coal mine fires in the world are reported from Jharia coalfield in Dhanbad district, Bihar State of India. In this paper we report the utility of day and night time Thematic Mapper thermal IR data (120 m x 120 m) for detecting and monitoring mine fires in Jharia. For this purpose, seven sets of TM data acquired between 1985 to 1995 have been analysed. Data processing methods include geometric and radiometric corrections, conversion of DN values to at-satellite temperatures and colour coding of temperature images. The pixel-integrated temperatures of 50{degrees}C and above have been classified as mine fires and achieved an accuracy of 81.2%. Also, assessed year wise, colliery-wise and geological formation-wise mine fire distribution in this area. Although TM thermal data is of coarser resolution, it enabled detection of mine fires mainly because of the large areal extent and high temperature range of mine fires. It ...

1996-08-01

445

Visualization of strong around motion calculated from the numerical simulation of Hyogo-ken Nanbu earthquake; Suchi simulation de miru Hyogoken nanbu jishin no kyoshindo  

Energy Technology Data Exchange (ETDEWEB)

Hyogo-ken Nanbu earthquake with a focus in the Akashi straits has given huge earthquake damages in and around Awaji Island and Kobe City in 1995. It is clear that the basement structure, which is steeply deepened at Kobe City from Rokko Mountains towards the coast, and the focus under this related closely to the local generation of strong ground motion. Generation process of the strong ground motion was discussed using 2D and 3D numerical simulation methods. The 3D pseudospectral method was used for the calculation. Space of 51.2km{times}25.6km{times}25.6km was selected for the calculation. This space was discretized with the lattice interval of 200m. Consequently, it was found that the basement structure with a steeply deepened basement, soft and weak geological structure thickly deposited on the basement, and earthquake faults running under the boundary of base rock and sediments related greatly to the generation of ...

1996-10-01

446

Trial design of pile foundation by limit state design; Genkai jotai sekkeiho ni yoru kui kiso no shisekkeirei  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces the summary of design guideline (draft) for the limit state design method for foundation structures, and examples of calculations on pile foundations. The limit states were set using the load to transformation curves, and the limit state No. 3 in particular assumed a large earthquake, a state that a foundation is fatally damaged because of rarely acting loads that lead to generation of displacement and loss of stability and functions. Ground survey coefficient, ground resistance coefficient, and ground property coefficient were defined especially as the safety coefficients. With respect to the displacement in the limit state No. 3, a restriction value was set for the plasticity of the foundation. Loads were given considerations of combination of permanent load, variation load, and accidental load, each having been set with a load coefficient. It was decided regarding earthquakes to discuss strength and toughness of ...

1994-09-01

447

Seismic response of pile-supported structure considering nonlinearity of superstructure and pile, and liquefaction of surrounding ground; Shuhen jiban no ekijoka oyobi kui no hisenkeisei wo koryoshita kui shiji tatemono no jishin oto kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Recent earthquake disasters have revealed the importance of countermeasures against soil Liquefaction in seismic design. In particular, the 1995 Hyogoken Nanbu earthquake caused several types of severe damages to pile foundations. This paper describes an analysis method for soil liquefaction using simple parameters such as SPT-N values and seismic response analyses for the pile-supported structure to consider soil-structure interaction effects and soil non-linearity using a modified Penzien model. It is important to find a way to determine the region of surrounding soil whose behavior is identical to that of piles. This paper adopts the thin layer element method to systematically determine the volume of the surrounding soil. The responses of pile-supported structure are similar, whether soil liquefaction and nonlinearity of pile are considered or not. However, the bending moment of pile become large as to soil liquefaction, ...

2000-01-10

448

PRA and Risk Informed Analysis  

Science.gov (United States)

The Boiler and Pressure Vessel Code (BPVC) of the American Society of Mechanical Engineers (ASME) has introduced a risk based approach into Section XI that covers Rules for Inservice Inspection of Nuclear Power Plant Components. The risk based approach requires application of the probabilistic risk assessments (PRA). Because no industry consensus standard existed for PRAs, ASME has developed a standard to evaluate the quality level of an available PRA needed to support a given risk based application. The paper describes the PRA standard, Section XI application of PRAs, and plans for broader applications of PRAs to other ASME nuclear codes and standards. The paper addresses several specific topics of interest to Section XI. Important consideration are special methods (surrogate components) used to overcome the lack of PRA treatments of passive components in PRAs. The approach allows calculations of conditional core damage probabilities ...

2006-01-01

449

PRA and Risk Informed Analysis  

Energy Technology Data Exchange (ETDEWEB)

The Boiler and Pressure Vessel Code (BPVC) of the American Society of Mechanical Engineers (ASME) has introduced a risk based approach into Section XI that covers Rules for Inservice Inspection of Nuclear Power Plant Components. The risk based approach requires application of the probabilistic risk assessments (PRA). Because no industry consensus standard existed for PRAs, ASME has developed a standard to evaluate the quality level of an available PRA needed to support a given risk based application. The paper describes the PRA standard, Section XI application of PRAs, and plans for broader applications of PRAs to other ASME nuclear codes and standards. The paper addresses several specific topics of interest to Section XI. Important consideration are special methods (surrogate components) used to overcome the lack of PRA treatments of passive components in PRAs. The approach allows calculations of conditional core damage probabilities both for ...

2006-01-01

450

PRA and Risk Informed Analysis  

International Nuclear Information System (INIS)

The Boiler and Pressure Vessel Code (BPVC) of the American Society of Mechanical Engineers (ASME) has introduced a risk based approach into Section XI that covers Rules for Inservice Inspection of Nuclear Power Plant Components. The risk based approach requires application of the probabilistic risk assessments (PRA). Because no industry consensus standard existed for PRAs, ASME has developed a standard to evaluate the quality level of an available PRA needed to support a given risk based application. The paper describes the PRA standard, Section XI application of PRAs, and plans for broader applications of PRAs to other ASME nuclear codes and standards. The paper addresses several specific topics of interest to Section XI. Important consideration are special methods (surrogate components) used to overcome the lack of PRA treatments of passive components in PRAs. The approach allows calculations of conditional core damage probabilities both for ...

451

Optimizing power plant cycling operations while reducing generating plant damage and costs  

Energy Technology Data Exchange (ETDEWEB)

This presentation describes a method for analyzing, quantifying, and minimizing the total cost of fossil, combined cycle, and pumped hydro power plant cycling operation. The method has been developed, refined, and applied during engineering studies at some 160 units in the United States and 8 units at the Irish Electric Supply Board (ESB) generating system. The basic premise of these studies was that utilities are underestimating the cost of cycling operation. The studies showed that the cost of cycling conventional boiler/turbine fossil power plants can range from between $2,500 and $500,000 per start-stop cycle. It was found that utilities typically estimate these costs by factors of 3 to 30 below actual costs and, thus, often significantly underestimate their true cycling costs. Knowledge of the actual, or total, cost of cycling will reduce power production costs by enabling utilities to more accurately dispatch their units to manage unit ...

1998-12-31

452

Materials issues in coal-fired combined cycle power generation systems: laboratory versus plant testing  

Energy Technology Data Exchange (ETDEWEB)

The successful development of coal-fired combined cycle power generation systems require that all component parts are manufactured from appropriate materials and that these materials give predictable in-service performance. High temperature corrosion resulting from coal-derived particulates, deposition and gaseous species, is potentially life limiting for many components in these systems. Realistic laboratory test methods are outlined for gasifier and gas turbine environments and these have been combined with a materials assessment method based on accurate dimensional metrology. Such tests have allowed the production of models of materials performance as well as accurate comparisons between laboratory and plant derived data. These initial models predict the performance of materials well in the gas turbine environment, but tend to under-predict the damage observed in real gasifier environments. The differences found between ...

1997-12-31

453

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process (forming and welding), ...

2010-07-01

454

Management of pitfalls for the successful clinical use of hypothermia treatment.  

Science.gov (United States)

Therapeutic hypothermia is a promising method for controlling intracranial pressure (ICP) in severely brain-injured patients. However, clinical data regarding the effect of brain hypothermia on overall outcome of these patients is limited. This may be because there are specific pitfalls associated with the clinical management of induced hypothermia in patients with severe traumatic brain injury (TBI). These pitfalls may be avoided by preventing specific risk factors when cooling is induced and with rewarming. However, these risk factors have not been well systematically discussed in the literature. In this paper, three categories of clinical issues regarding the management of brain hypothermia are discussed: (1) stress-induced secondary brain injury mechanisms; (2) technical aspects of intensive care unit (ICU) cooling management; and (3) rewarming rates and methods. For patients with a Glasgow Coma Scale (GCS) score of less than 8, management ...

2009-03-01

455

Intrapartum FHR monitoring and neonatal CT brain scan  

Energy Technology Data Exchange (ETDEWEB)

The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) ...

1982-12-01

456

Intrapartum FHR monitoring and neonatal CT brain scan  

International Nuclear Information System (INIS)

The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged ...

1982-01-01

457

Environmental risk assessment. A method for determination and evaluation of the risks of harmful changes in air, water and soils due to hazardous substances which are handled in technical facilities - aspects which are relevant to the Environmental Liabilities Law. Die Beurteilung von Umweltrisiken. Eine Methode zur Ermittlung und Bewertung der Risiken einer schaedlichen Veraenderung der Umweltmedien durch umweltgefaehrdende Stoffe in technischen Anlagen unter dem Aspekt des Umwelthaftungsgesetzes  

Energy Technology Data Exchange (ETDEWEB)

The criterion the study is based on in evaluating environmental risks is the possibility of harmful changes in air, water and soils rather than the harmful environmental impacts these changes are caused by. The two significant criteria, i.e. the evaluated environmental hazards potentials or 'value parameters', and the evaluated damage-to-the-environment probabilities or 'safety parameters', reveal the respective environmental risks or 'risk factors'. These risk factors are classified by 23 environmental risk parameters for differentiation between low-risk and high-aid for pollution abatement measures provided that one fixes acceptance limits for the environmental parameters. As a rule the environmental risks of technical facilities which handle hazardous materials can be evaluated appropriately and the results can be compared. (orig./HSCH).

1992-02-07

458

Development of production methods of volume source by the resinous solution which has hardening  

CERN Document Server

Volume sources is used for standard sources by radioactive measurement using Ge semiconductor detector of environmental sample, e.g. water, soil and etc. that require large volume. The commercial volume source used in measurement of the water sample is made of agar-agar, and that used in measurement of the soil sample is made of alumina powder. When the plastic receptacles of this two kinds of volume sources were damaged, the leakage contents cause contamination. Moreover, if hermetically sealing performance of volume source made of agar-agar fell, volume decrease due to an evaporation off moisture gives an error to radioactive measurement. Therefore, we developed the two type methods using unsaturated polyester resin, vinilester resin, their hardening agent and acrylicresin. The first type is due to dispersing the hydrochloric acid solution included the radioisotopes uniformly in each resin and hardening the resin. The second is due to ...

2002-01-01

459

In-situ measurement of epithelial tissue optical properties: Development and implementation of diffuse reflectance spectroscopy techniques  

Science.gov (United States)

Cancer is a severe threat to human health. Early detection is considered the best way to increase the chance for survival. While the traditional cancer detection method, biopsy, is invasive, noninvasive optical diagnostic techniques are revolutionizing the way that cancer is diagnosed. Reflectance spectroscopy is one of these optical spectroscopy techniques showing promise as a diagnostic tool for pre-cancer detection. When a neoplasia occurs in tissue, morphologic and biochemical changes happen in the tissue, which in turn results in the change of optical properties and reflectance spectroscopy. Therefore, a pre-cancer can be detected by extracting optical properties from reflectance spectroscopy. This dissertation described the construction of a fiberoptic based reflectance system and the development of a series of modeling studies. This research is aimed at establishing an ...

2009-01-01

460

Textured silicon nitride: processing and anisotropic properties  

International Nuclear Information System (INIS)

Textured silicon nitride (Si_3N_4) has been intensively studied over the past 15 years because of its use for achieving its superthermal and mechanical properties. In this review we present the fundamental aspects of the processing and anisotropic properties of textured Si_3N_4, with emphasis on the anisotropic and abnormal grain growth of #beta#-Si_3N_4, texture structure and texture analysis, processing methods and anisotropic properties. On the basis of the texturing mechanisms, the processing methods described in this article have been classified into two types: hot-working (HW) and templated grain growth (TGG). The HW method includes the hot-pressing, hot-forging and sinter-forging techniques, and the TGG method includes the cold-pressing, extrusion, tape-casting and strong magnetic field alignment techniques for #beta#-Si_3N_4 seed crystals. Each processing technique is thoroughly discussed in ...

2008-07-01

461

Schottky barrier and homojunction gallium arsenide solar cells  

Energy Technology Data Exchange (ETDEWEB)

New techniques were developed to construct Schottky barrier and homojunction solar cells on GaAs substrates. Schottky barrier metal-semiconductor solar cells were produced for the first time on p-type GaAs substrate using a sputter-deposition method to form the barrier. The sputter deposition of gold or gold/palladium is the key to the method since normal thermal evaporation of gold onto p-type GaAs produces ohmic contacts. The results of this investigation are consistent with the idea that sputter damage produces donor type surface states on GaAs. Barrier heights were measured for both p-type sputtered and n-type thermally evaporated diodes using current-voltage and capacitance-voltage methods. Deep-level transient spectroscopy was used to identify the trap center concentration and energy levels for both diodes in an effort to explain the relatively large dark current in the p-type sputtered diodes. ...

1983-01-01

462

Partitioning Tracers for In-Situ Measurement of Nonaqueous Phase Liquids in the Subsurface - Final Report - 09/15/1996 - 09/14/2000  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifer systems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This proposal outlines an ...

2000-09-14

463

Discovery of low-affinity preproinsulin epitopes and detection of autoreactive CD8 T-cells using combinatorial MHC multimers.  

Science.gov (United States)

Autoreactive cytotoxic CD8 T-cells (CTLs) play a key pathogenic role in the destruction of insulin-producing beta-cells resulting in type 1 diabetes. However, knowledge regarding their targets is limited, restricting the ability to monitor the course of the disease and immune interventions. In a multi-step discovery process to identify novel CTL epitopes in human preproinsulin (PPI), PPI was digested with purified human proteasomes, and resulting COOH-fragments aligned with algorithm-predicted HLA-binding peptides to yield nine potential HLA-A1, -A2, -A3 or -B7-restricted candidates. An UV-exchange method allowed the generation of a repertoire of multimers including low-affinity HLA-binding peptides. These were labeled with quantum dot-fluorochromes and encoded in a combinatorial fashion, allowing parallel and sensitive detection of specific, low-avidity T-cells. Significantly increased frequencies of T-cells against four novel PPI epitopes ...

2011-05-31

464

Real-time monitoring of dosimetry and image quality during digital radiology examinations  

International Nuclear Information System (INIS)

Objective: To explore the feasibility of real-time monitoring exposure dose and image quality by using the data stored in the DICOM image archive of direct digital radiography system. Methods: Model TO. 16 was exposed, the current increased gradually from 0.5 to 125 mAs. The displayed number of model A( diameter 11.1 mm), D (diameter 4.0 mm) and J( diameter 0.7 mm) were recorded, and the detect factors (H_T) was also calculated. Images were sent to workstation before the end of DR examination. An automatic procedure was implemented to extract dose data and exposure parameters from the DICOM header file. Maximum, minimum and 3rd quartile values were preinstalled. Mean values exceeding the threshold trigger alarm signal to guide radiologist to explore the cause. Results: When the current of point A was less than 10 mAs and the current of point D and J were less than 16 mAs, the detect factor (H_T) increased with the rise of ...

2009-12-01

465

Fault detection and diagnosis of a gearbox in marine propulsion systems using bispectrum analysis and artificial neural networks  

Science.gov (United States)

A marine propulsion system is a very complicated system composed of many mechanical components. As a result, the vibration signal of a gearbox in the system is strongly coupled with the vibration signatures of other components including a diesel engine and main shaft. It is therefore imperative to assess the coupling effect on diagnostic reliability in the process of gear fault diagnosis. For this reason, a fault detection and diagnosis method based on bispectrum analysis and artificial neural networks (ANNs) was proposed for the gearbox with consideration given to the impact of the other components in marine propulsion systems. To monitor the gear conditions, the bispectrum analysis was first employed to detect gear faults. The amplitude-frequency plots containing gear characteristic signals were then attained based on the bispectrum technique, which could be regarded as an index actualizing forepart gear faults diagnosis. ...

2011-03-01

466

DNA rearrangements from #gamma#-irradiated normal human fibroblasts preferentially occur in transcribed regions of the genome  

International Nuclear Information System (INIS)

Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of ...

2003-08-17

467

Machine fault signature analysis by midpoint-based empirical mode decomposition  

Science.gov (United States)

The fault signature can be revealed by vibration analysis in machine fault detection and diagnosis. Empirical mode decomposition (EMD) is a self-adaptive method that can decompose a vibration signal into informative intrinsic mode functions (IMFs). This paper addresses the improvement of the weakness of the traditional EMD algorithm and presents a new midpoint-based EMD method for effective fault signature analysis of a rotating machine. In the proposed method, geometrical midpoints of successive extrema are employed to estimate the local mean of an analyzed signal. Signal decomposition is then self-adaptively performed to achieve IMFs through removal of the midpoint-based local means. The representative IMF containing fault information is selected for identifying the fault signature. The effectiveness of the proposed method was verified by means of simulation and an application to ...

2011-01-01

468

Diagnosis of breast cancer with MR imaging using the magnetization transfer contrast and a newly-developed breast surface coil for the supine position  

Energy Technology Data Exchange (ETDEWEB)

We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation ...

1998-09-01

469

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be ...

1978-04-01

470

Comparison of methods to measure the rate of neutral free radical production by photo-deionization of negative ion beams  

Energy Technology Data Exchange (ETDEWEB)

Two measurement methods to determine the rate of neutral free radical production by the photo-deionization of negative ion beams (PDINIB) are introduced. These methods, namely, photoelectron-current measurement by low-frequency electro-modulation probe (PMMP) and measurement of decrease in the negative-ion beam current (DNIC) were employed to evaluate the production rate in a trial surface-processing apparatus developed in the author's laboratory utilizing a steady-flux refined beam of neutral free radicals (RBNR) produced by the PDINIB procedure. A {sup 63}Cu{sup -} negative ion beam of kinetic energy E{sub i} varied up to 15 keV was irradiated with a 514.5 nm visible light beam from a 25 W CW Ar{sup +} ion laser. The detection limit of the production rate by the PMMP setup was as high as 6 x 10{sup 9} s{sup -1} under the condition that E{sub i}=15 keV, the negative-ion beam current I{sub i}=4 {mu}A and the laser ...

2003-05-01

471

The utilization of non-destructive method for in-service inspections in nuclear power components  

International Nuclear Information System (INIS)

To ensure safe and reliable power production nuclear power plants must be operated at high level. Non destructive in-service inspections are inseparable part of the effort. Non destructive in-service inspections are essential on the ground of degradation mechanisms existence in nuclear power components. Degradation processes are constituent of operation of each industrial installation including nuclear power plants. Mission of non-destructive testing is degradation detection, closer characterization of its parameters (dimensions) and to supply as much information as possible to nuclear power plant operator. Eddy current testing method can be assigned to surface - volumetric methods. Method enables inspection of electrically conductive materials. It is particularly suitable for inspection of non-ferromagnetic materials like austenitic stainless steel and brass. The method is used for ...

2006-01-01

472

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-11-16

473

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-07-01

474

Realistic Earth matter effects and a method to measure small \\theta_{13} in the detection of supernova neutrinos  

CERN Document Server

In this paper, we first calculate the realistic Earth matter effects on the detection of type II supernova neutrinos at the Daya Bay reactor neutrino experiment which is currently under construction. It is found that the Earth matter effects depend on the neutrino incident angle \\theta, the neutrino mass hierarchy \\Delta m_{31}^{2}, the crossing probability at the high resonance region inside the supernova, P_H, the neutrino temperature, T_{\\alpha}, and the pinching parameter in the neutrino spectrum, \\eta_{\\alpha}. We give the expression for the dependence of P_H on the neutrino mixing angle \\theta_{13}. With this we obtain the relations between \\theta_{13} and the event numbers for various reaction channels of supernova neutrinos. Using these relations, we propose a possible way to measure \\theta_{13} smaller than 1.5^\\circ. Such a sensitivity cannot be achieved by the Daya Bay neutrino experiment (the sensitivity of the Daya Bay experiment is ...

2008-01-01

475

Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic ...

1997-05-27

476

Method for controlling the liquid level of a steam generator for a sodium-cooled fast breeder reactor  

International Nuclear Information System (INIS)

Object: To control the average liquid level of each steam generator at a constant level irrespective of the flow rate of sodium thereby to decrease change in the retained amount of sodium and at the same time to improve the load response characteristic. Construction: A method for decreasing to as large an extent as possible a change in the amount of sodium retained in a steam generator due to change in the flow rate, which comprises the steps of detecting the main recirculating flow rate of liquid sodium by the use of a sodium flow rate detector, amplifying the detected flow rate signal depending upon the ratio between the flow rates respectively in a super-heater and a re-heater (distribution ratio), delivering the amplified signal to a function generator which generates a liquid level setting signal for maintaining the respective average liquid levels of the super-heater and the re-heater at constant levels irrespective ...

477

MRI, CT, sonography and thallium-technetium subtraction scintigraphy for the detection of parathyroid disease: a four-year experience  

International Nuclear Information System (INIS)

Sonography, subtraction scintigraphy, computed tomography and MRI were compared in 100 patients who had surgery 105 times for hyperparathyroidism (HPT). Surgical and pathological data were available for all operations. A total of 105 MR, 77 CT, 84 sonograms and 70 subtraction scintigrams were performed. The ability of the imaging modalities, individually and in combination, to detect HPT, histology, size, concomitant thyroid disease and location of the diseased glands has been evaluated. For primary HPT, sensitivity ranged from 68% for MRI to 40% for scintigraphy but was much lower for tertiary HPT with all modalities. The ability to identify diseased glands was strongly size dependent for all methods. If patients had had previous neck surgery, the most sensitive methods were MRI and scintigraphy and this also held true for patients with concomitant thyroid disease and ectopically located glands. The findings presented ...

478

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative characterization of ...

2009-12-01

479

Detecting exposure to environmental organic toxins in individual cells: towards development of a micro-fabricated device  

Energy Technology Data Exchange (ETDEWEB)

A new method is being developed to quickly screen for the human exposure potential to polycyclic aromatic hydrocarbons (PAHs) and organochlorines (OCs). The development involves two key elements: identifying suitable signals that represent intracellular changes that are specific to PAH and OC exposure, and constructing a device to guide the biological cell growth so that signals from individual cells are consistent and reproducible. We are completing the identification of suitable signals by using synchrotron radiation-based (SR) Fourier-transform infrared (FTIR) spectromicroscopy in the mid-infrared region (4000-400 cm-1). Distinct changes have been observed in the IR spectra after treatment of human cells in culture medium with PAHs and OCs. The potential use of this method for detecting exposure to PAHs and OCs has been tested and compared to a reverse transcription polymerase chain reaction (RT-PCR) assay that ...

1999-01-10

480

Automated method for determining location and magnitude of leaks inside a PWR containment  

Energy Technology Data Exchange (ETDEWEB)

Thermal-hydraulics analysis can be used to determine location and magnitude of leaks inside a pressurized water reactor (PWR) containment, as required by plant technical specifications. The major advantage of this detection method is that it minimizes radiation exposure of maintenance personnel because most of the leak detection process is performed from the control room outside the containment. In addition, such a program allows for the elimination of pipe whip restraints and jet impingement shields, eliminating costs for maintenance of these supports and shields in older plants and lowering construction costs for new plants. Previously, only simple single-node containment models were used for determining leakage magnitude. This paper presents a more sophisticated multinode approach for determining the magnitude and location. The resulting sensitivities to leak can be programmed into the plant's computer system. ...

1986-01-01

481

Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion  

International Nuclear Information System (INIS)

Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.

1993-01-01

482

Simultaneous measurement of the neutron capture and fission yields of "2"3"3U  

International Nuclear Information System (INIS)

We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)

2007-04-22

483

Radiolabelling of. cap alpha. -bungarotoxin to high specific radioactivity with complete retention of biological activity  

Energy Technology Data Exchange (ETDEWEB)

Radioiodinated ..cap alpha..-bungarotoxin, the venom of Bungarus multicinctus, is commonly used for the detection and quantification of nicotinic acetylcholine receptors (nAChR) and anti-nAChR antibodies. A radioiodination method is described which is simple and yields a fully active product which, after fractionation, has a specific activity tenfold higher (900 Ci/mmol) than those routinely used, resulting in enhanced sensitivity of assays and conservation of material, especially muscle extracts.

1984-10-01

484

Pitting corrosion of copper and copper alloys. (Latest citations from the Metals Abstracts alloys index database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the pitting corrosion of copper and copper alloys, in different media, with some references to methods for protecting against such corrosion. Included are factors contributing to the onset of pitting corrosion. Emphasis is placed on exposure to water, especially in tubing for heat exchangers and water conduits. Many of the citations present studies on exposure to sea water. Some references pertain to the detection of pitting corrosion in installations and the evaluation of the degree of pitting present. (Contains 250 citations and includes a subject term index and title list.)

1993-09-01

485

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

486

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

487

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

488

Monitoring of "1"1"0"mAg in the Daya Bay marine environment  

International Nuclear Information System (INIS)

The author describes the Gamma -spectrum analysis results of "1"1"0"mAg, the method used, and the coincidence correction theory on which the analysis is based. The samples were placed at the upper end of the detector. The monitoring results of "1"1"0"mAg in the surrounding marine area from the beginning of operation of the Daya Bay nuclear power plant are reviewed as well. The results showed that "1"1"0"mAg traces were detected in some marine species. However, the concentrations observed are far below the National Standard limits

1999-09-20

489

Modular symmetry in parametrically excited quantum oscillators  

Energy Technology Data Exchange (ETDEWEB)

It is shown that when a quantum mechanical oscillator is parametrically excited there are special values of the parameters for which the system will pass periodically through a lattice of coherent states associated with the modular group [Gamma]. It is shown that these [Gamma] transits can be used to determine unknown parameters. A method is given for detecting the transits experimentally and is made possible by the existence of three families of states associated with modular forms that are orthogonal to the lattice. For isotropic states the three families occur in [ital D]-mode systems with [ital D][gt]10, 14, and 26.

1993-11-29

490

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

491

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

492

Heliophysics Event Knowledgebase for the Solar Dynamics Observatory and Beyond  

CERN Document Server

The immense volume of data generated by the suite of instruments on SDO requires new tools for efficient identifying and accessing data that is most relevant to research investigations. We have developed the Heliophysics Events Knowledgebase (HEK) to fill this need. The HEK system combines automated data mining using feature-detection methods and high-performance visualization systems for data markup. In addition, web services and clients are provided for searching the resulting metadata, reviewing results, and efficiently accessing the data. We review these components and present examples of their use with SDO data.

2010-01-01

493

Gases in insulating oil - analysis of dissolved gases using a portable chromatograph  

Energy Technology Data Exchange (ETDEWEB)

New technological advances make it possible to perform on site gas-in-oil analysis quickly and efficiently. Gas-in-oil analysis is crucial in assessing the status of oil-filled electrical equipment. The new technique is used for extracting and measuring gases dissolved in electrical insulating oil. On-site sampling requires the use of a specially designed 100 ml capacity syringe. Extraction of the dissolved gases is made with a precise ratio of oil to air. A comparison was made between the analysis of the on-site and the laboratory techniques. Results showed that the detection limits of the on-site technique were comparable to those obtained by laboratory methods.

1996-07-01

494

Flow cytogenetics methodology and applications  

Energy Technology Data Exchange (ETDEWEB)

Flow cytogenetics is a rapidly developing technology which complements rather than supplants the traditional methods of cytogenetic analysis. As an adjunctive approach to chromosome classification, flow systems measurements of isolated chromosomes give new information relative to the enrichment of A-T or G-C base sequences on specific chromosomes. As a result, chromosomal fluorescence polymorphisms both within and among individuals that are not always associated with banding polymorphisms can be detected. Finally, flow sorting provides bulk quantities of highly purified chromosomes for use in biochemical studies. Methodology is detailed. (PSB)

1982-10-17

495

Computed tomography in spinal osteoblastoma  

International Nuclear Information System (INIS)

In order to stress the role of computed tomography (CT) in the evaluation of benign spinal osteoblastoma, the authors examined by CT 10 patients with surgically and histologically proved osteoblastomas of the spine. Basing on surgical and histopathological findings CT proved to be a very important method for attesting the presence of the tumors (usually showed by radiographic examination), and specially for their staging and follow-up. CT in fact showed the real extent of the tumor into the spinal canal and towards the paraspinal soft tissues, and allowed the aerly detection of post surgical relapses. The authors conclude that CT is a primary diagnostic modality for preoperative planning and follow-up of benign osteoblastoma.

1986-01-01

496

A new method for sealing containers with liquid samples for radioactivity measurements  

International Nuclear Information System (INIS)

It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)

2002-08-01

497

Sol-gel-immobilized Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography  

International Nuclear Information System (INIS)

The sol-gel-immobilized Tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy)_3 "2"+] electrogenerated chemiluminescence (ECL) sensor was applied to the reversed-phase high-performance liquid chromatography (HPLC) determination of phenothiazine derivatives (promazine, chlorpromazine, triflupromazine, thioridazine, and trifluoperazine) and erythromycin in human urine samples. In this method, Ru(bpy)_3 "2"+ was immobilized in sol-gel-derived titania (TiO_2)-Nafion nanocomposite films coated on a dual platinum electrode. This method eliminates an extra pump needed for the delivery of Ru(bpy)_3 "2"+ reagent into a reaction/observation zone in front of photomultiplier tube because the immobilized-Ru(bpy)_3 "2"+ is recycled on the electrode surface by an applied potential at +1.3 V versus Ag/AgCl (3 M NaCl) reference electrode. The resulting analytical performances such as detection limit, working range, sensitivity, and measurement ...

2005-06-13

498

Sol-gel-immobilized Tris(2,2'-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography  

Energy Technology Data Exchange (ETDEWEB)

The sol-gel-immobilized Tris(2,2'-bipyridyl)ruthenium(II) [Ru(bpy){sub 3} {sup 2+}] electrogenerated chemiluminescence (ECL) sensor was applied to the reversed-phase high-performance liquid chromatography (HPLC) determination of phenothiazine derivatives (promazine, chlorpromazine, triflupromazine, thioridazine, and trifluoperazine) and erythromycin in human urine samples. In this method, Ru(bpy){sub 3} {sup 2+} was immobilized in sol-gel-derived titania (TiO{sub 2})-Nafion nanocomposite films coated on a dual platinum electrode. This method eliminates an extra pump needed for the delivery of Ru(bpy){sub 3} {sup 2+} reagent into a reaction/observation zone in front of photomultiplier tube because the immobilized-Ru(bpy){sub 3} {sup 2+} is recycled on the electrode surface by an applied potential at +1.3 V versus Ag/AgCl (3 M NaCl) reference electrode. The resulting analytical performances such as detection limit, ...

2005-06-13

499

Modeling pitting corrosion damage of high-level radioactive-waste containers, with emphasis on the stochastic approach  

Energy Technology Data Exchange (ETDEWEB)

Recent efforts to identify methods of modeling pitting corrosion damage of high-level radioactive-waste containers are described. The need to develop models that can provide information useful to higher level system performance assessment models is emphasized, and examples of how this could be accomplished are described. Work to date has focused upon physically-based phenomenological stochastic models of pit initiation and growth. These models may provide a way to distill information from mechanistic theories in a way that provides the necessary information to the less detailed performance assessment models. Monte Carlo implementations of the stochastic theory have resulted in simulations that are, at least qualitatively, consistent with a wide variety of experimental data. The effects of environment on pitting corrosion have been included in the model using a set of simple phenomenological equations relating the parameters of the stochastic ...

1993-01-01

500

Application of constraint-sensitive fracture mechanics to the assessment of girth weld integrity  

Energy Technology Data Exchange (ETDEWEB)

The dominant fracture parameters used in fracture mechanics analyses of pipelines are related to the asymptotic crack-tip stress and strain fields at the crack tip. This paper reviewed new developments in constraint-sensitive fracture mechanics for the assessment of pipeline girth weld integrity. Constraint theories and experimental studies were evaluated. Constraint models included brittle fracture models and ductile fracture models. Constraint models for brittle fracture are based on weakest link statistics and Weibull distribution. Specifically designed experimental tests are often necessary to derive the damage parameters of ductile fracture models. Experimental test data must then be calibrated with finite element analyses (FEA) to ensure that the correct damage parameters are chosen. The effects of specimen geometry and loading condition are characterized by the T stress, while Q stress is the hydrostatic stress defined by the difference ...

2004-07-01