The forward modelling and the prestack reverse time migration of seismic P-SV wave field was carried out in 2-D models of isotropic and anisotropic media which allow separation of P-SV and SH motion. The P-SV wave field can be described by a system of hyperbolic, first order differential equations in terms of particle velocity and stress. The system of five equations and five unknowns, namely horizontal (U) and vertical (V) velocity components, and three components of stress (T{sub xx}, T-z{sub z} and T{sub xz}) was solved numerically using second order space and forth order time finite differences operators. In order to attenuate numerical dispersion, a staggered grid was used. (author). 48 refs., 5 figs
Seismic monitoring at the Las Tres Virgenes, BCS, geothermal field started in 1992 with an analog station of vertical components detecting a large number of earthquakes of varying magnitudes. In February 1993, a seismic network was installed, composed of six digital stations DR-2000-with S-6000 and S-5000 sensors and three registration channels (N-S, E-W and vertical). This was the basis for the development of a program to correct arrival-time data for P and S waves due to instrument drift. From January to April 1994 and May to August 1995, based on the 170 seismic events recorded, a velocity model was proposed. From December 1995 to July 1996, seismic data were processed and interpreted, and zones of occurrence were determined for events according to magnitude and the predominant noise in the field. From September 2003 to December 2004, 10 seismic stations (permanent and temporary) were installed and monitored and it was concluded the most active fault system was El Volcan. From ...
The standards mapping methods are limited by the lack of information between surface measures and wells profiles. The cross well seismic survey has proven being an effective high-resolution method for reservoirs characterization due its high frequency band. In this work, a 2-D finite differences algorithm for numerical cross well seismic simulation was developed, based in the approach of 2nd order for the time derivatives and 4th order for the space derivatives. In relation to the imaging techniques, it was introduced a reverse time migration method based in the solutions of the wave equation in time for cross well seismic data by the method of the finite differences exclusively. The results of reverse time migration has showed that layers with 90 cm thickness for P-waves could be visualized in migrated sections with excellent resolution. The high frequency cross well seismic data combined with reverse time migration have the potential for revealing never seeing reservoir details using ...
Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like the crystal-amorphous transition temperature and the super ...
Current advanced CMOS source/drain engineering involves the use of amorphizing implants with 3D geometry. Upon annealing, the induced transient enhanced diffusion (TED) can only be accurately predicted if the amorphized region is correctly modeled, as well as the formation and evolution of extended defects, particularly 3 1 1's and dislocation loops. In addition to the extended defects, already modeled in the atomistic kinetic Monte-Carlo simulator DADOS, we have developed a physically based modeling approach for the implant-induced damage build-up, amorphization and recrystallization, suitable to handle device-size process simulation. It is based on amorphous pockets (3D, irregular shape agglomerates of an arbitrary number of interstitials and vacancies, plus trapped impurities) with a size-dependent activation energy for recombination. The model is able to reproduce experimental aspects like the crystal-amorphous transition temperature and the super linear ...
We discuss atomistic simulations of ion implantation and annealing of Si over a wide range of ion dose and substrate temperatures. The DADOS Monte Carlo model has been extended to include the formation of amorphous regions, and this allows simulations of dopant diffusion at high doses. As the dose of ions increases, the amorphous regions formed by cascades eventually overlap, and a continuous amorphous layer is formed. In that case, most of the excess interstitials generated by the implantation are swept to the surface as the amorphous layer regrows, and do not diffuse in the crystalline region. This process reduces the amount of transient enhanced diffusion (TED) during annealing. This model also reproduces the dynamic annealing during high temperature implants. In this case, the local amorphous regions regrow as the implant proceeds, without the formation of a continuous amorphous layer. For sufficiently high temperatures, each cascade is annealed out ...
Ion implantation and subsequent annealing are essential stages in today's advanced CMOS processing. Although the dopant implanted profile can be accurately predicted by analytical fits calibrated with SIMS profiles, the damage has to be estimated with a binary collision approximation implant simulator. Some models have been proposed, like the '+n', in an attempt to simplify the anneal simulation. We have used the atomistic kinetic Monte Carlo dados to elucidate which are the implant modeling features most relevant in the simulation of transient enhanced diffusion (TED). For the experimental conditions studied we find that the spatial correlation of the I, V Frenkel pairs is not critical in order to yield the correct I supersaturation, that can be simulated just taking into account the net I-V excess distribution. In contrast to, simulate impurity clustering/deactivation when there is an impurity concentration comparable to the net I-V excess, the full I and V ...
A plan has been put forth to strategically thin northern California forests to reduce fire danger and improve forest health. The resulting biomass residue, instead of being open burned, can be converted into ethanol that can be used as a fuel oxygenate or an octane enhancer. Economic potential for a biomass-to-ethanol facility using this softwood biomass was evaluated for two cases: Stand-alone and co-located. The co-located case refers to a specific site with an existing biomass power facility owned by Wheelabrator Environmental Systems Inc. near Martell, California. A two-stage dilute acid hydrolysis process is used for the production of ethanol from softwoods, and the residual lignin is used to generate steam and electricity. For a plant processing 800 dry tonnes per day of feedstock, the co-located case is an economically attractive concept. Total estimated capital investment is approximately $ 70 million for the co-located case. The resulting internal rate of return is about 24% ...
Objective: To retrospectively evaluate the results of conservative therapy using escorpal iodine-125 (model 6711, Amershan) plaque for brachytherapy of choroidal melanoma. Materials And Methods: We evaluated 49 patients with choroidal melanoma treated at 'Hospital do Cancer', Sao Paulo, Brazil, from March 2001 to January 2003. The following clinical parameters were analyzed and correlated with local control and survival rate: gender, age, lesion dimension, treatment duration, as well as doses in apex and base of the tumors. Results: The maximum diameter and height of the base of the tumors treated were 17 mm and 12 mm, respectively. Doses at those points ranged from 213 to 463 Gy (median: 347 Gy) and 51 to 250 Gy (median: 91 Gy), respectively. The actuarial rates of ocular preservation, disease free survival and ocular preservation in 2-years were 96%, 93.5% and 96.3%, respectively. A tumor height < 6 mm was the only predictive factor for local control (p = ...
In this article the methodology followed to diagnose the performance of the equipment where heat is transferred from the feed water, condensate and circulation water systems in fossil power plants (FPP). The data collection is made with the unit in normal operation, using local instrumentation without taking the equipment out of service for its installation. The equipment diagnosis is made through the analysis of the collected data in actual operation and the design data; for this purpose a thermal balance of the interested systems is performed to obtain all the conditions an operation data. Later on the performance indicative parameters (PIP) of actual operation and design are calculated and compared one against the other. Such a comparison reveals the performance deterioration and the possible equipment faults. The data obtained and the supplementary information are stored in a data base whose objective is that Comision Federal de Electricidad has on hand a prompt access to them in ...
The hospitals are important consumers of energy. At the General Hospital of Zone (HGZ) N of the IMSS in Aguscalientes (HGZ N . IMSS Ags.), the diesel oil is the main fuel that is used to satisfy the requirements of thermal energy of the hospital. According to the data collected by this author, this fuel represented in 2001, 75% of its total energy consumption and the 67.9% of its total costs in energy that ascended to $396.131 (December 2001 Dollars) Since this last amount represents an important percentage of the total expenses of the hospital (29.367 million dollars) it is important to determine the technical-economic possibilities of thermal energy saving of the hospital. The HGZ N 1 IMSS Ags. is located in a ampler conglomerate where the IMSS units are located, such as, the regional laundry, the sport unit, the center of social security, the familiar medicine unit N 1 and the hospital. Nevertheless departing from the installation of the electrical systems and the provision of steam ...
It turns out of interest to Comision Federal de Electricidad and Petroleos Mexicanos to reduce costs of fuel oil, reducing the viscosity of the residues petroleum of high vacuum distillation emulsifying these with water. The parameters that define the characteristics of the emulsions are mainly the relation of their components, viscosity, size and drop distribution and its stability. The experimental work began producing emulsions in form of lots, using samples of approximately 500 milliliters of vacuum residue. In this first stage, at different concentrations, were examined eight different surfactants, as well as combinations among them, also seven different stabilizers were used. With these tests it has been managed to identify the concentrations, as well as the most adequate relations of surfactants and stabilizers for the production of emulsions of vacuum residues in water. The size and drop distribution has been determined by means of an optical LEICA microscope, model DMLS, that ...