Absorbent for removal of heavy metal impurities from gases and its production
Energy Technology Data Exchange (ETDEWEB)
This is an adsorbent for removal of heavy metal impurities from gases. In addition to activated charcoal and ferric chloride, it contains a nonwoven dacron filter material to increase the purification level. The filter material has the following mass % composition: 27-54 activated charcoal, 7-35 ferric chloride, the remainder dacron filter material. The activated charcoal is applied to the dacron filter and the resulting mixture is treated with a ferric chloride solution. The activated charcoal is applied in the form of a suspension with a particle diameter of 0.1-0.16 mm. The treatment solution is 3-20% ferric chloride.
1981-03-23
Quantification of the thrombogenicity of Dacron aortic prostheses
International Nuclear Information System (INIS)
Eight patients with double-velour Dacron aorto-femoral grafts implanted for 2-60 months were studied. Indium-111-labelled platelets were found to have a shortened mean platelet lifespan (MPLS) of 138 +- 32 hours compared with the normal platelet lifespan of 224 +- 23 hours. Labelled platelets accumulated on all grafts, irrespective of graft age, to a maximum of 1,80 +- 0,83% of whole body radioactivity; thereafter graft radio-activity decreased. This suggests that platelets on the graft are in dynamic equilibrium with those in the circulation. Platelets may be lost from the graft by embolization or radioactivity may be released because of platelet lysis. Although MPLS may depend on the age and surface area of the graft, concomitant arterial disease probably also contributes to the shortened MPLS.
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an alternative therapy to ...
1998-03-01
Platelet thrombosis in cardiac-valve prostheses
International Nuclear Information System (INIS)
The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day ...
1989-06-08
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
