WorldWideScience

Sample records for circe devices

  1. Single-arm evaluation of the AccuCirc device for early infant male circumcision in Botswana.

    Science.gov (United States)

    Plank, Rebeca M; Wirth, Kathleen E; Ndubuka, Nnamdi O; Abdullahi, Rasak; Nkgau, Maggie; Lesetedi, Chiapo; Powis, Kathleen M; Mmalane, Mompati; Makhema, Joseph; Shapiro, Roger; Lockman, Shahin

    2014-05-01

    : Existing devices for early infant male circumcision (EIMC) have inherent limitations. We evaluated the newly developed AccuCirc device by circumcising 151 clinically well, full-term male infants with birth weight ≥2.5 kg within the first 10 days of life from a convenience sample in 2 hospitals in Botswana. No major adverse events were observed. There was 1 local infection, 5 cases of minor bleeding, and 1 case of moderate bleeding. In 3 cases, the device made only partial incisions that were completed immediately by the provider without complications. Parental satisfaction was high: >96% of mothers stated that they would circumcise a future son. The pre-assembled, sterile AccuCirc kit has the potential to overcome obstacles related to supply chain management and on-site instrument disinfection that can pose challenges in resource-limited settings. In our study, the AccuCirc was safe and it should be considered for programmatic EIMC in resource-limited settings.

  2. Estimating the Cost of Early Infant Male Circumcision in Zimbabwe: Results From a Randomized Noninferiority Trial of AccuCirc Device Versus Mogen Clamp

    Science.gov (United States)

    Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K.; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M.; Thirumurthy, Harsha

    2015-01-01

    Background: Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Methods: Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. Results: The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. Conclusions: EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization. PMID:26017658

  3. Estimating the Cost of Early Infant Male Circumcision in Zimbabwe: Results From a Randomized Noninferiority Trial of AccuCirc Device Versus Mogen Clamp.

    Science.gov (United States)

    Mangenah, Collin; Mavhu, Webster; Hatzold, Karin; Biddle, Andrea K; Madidi, Ngonidzashe; Ncube, Getrude; Mugurungi, Owen; Ticklay, Ismail; Cowan, Frances M; Thirumurthy, Harsha

    2015-08-15

    Safe and cost-effective programs for implementing early infant male circumcision (EIMC) in Africa need to be piloted. We present results on a relative cost analysis within a randomized noninferiority trial of EIMC comparing the AccuCirc device with Mogen clamp in Zimbabwe. Between January and June 2013, male infants who met inclusion criteria were randomized to EIMC through either AccuCirc or Mogen clamp conducted by a doctor, using a 2:1 allocation ratio. We evaluated the overall unit cost plus the key cost drivers of EIMC using both AccuCirc and Mogen clamp. Direct costs included consumable and nonconsumable supplies, device, personnel, associated staff training, and environmental costs. Indirect costs comprised capital and support personnel costs. In 1-way sensitivity analyses, we assessed potential changes in unit costs due to variations in main parameters, one at a time, holding all other values constant. The unit costs of EIMC using AccuCirc and Mogen clamp were $49.53 and $55.93, respectively. Key cost drivers were consumable supplies, capacity utilization, personnel costs, and device price. Unit prices are likely to be lowest at full capacity utilization and increase as capacity utilization decreases. Unit prices also fall with lower personnel salaries and increase with higher device prices. EIMC has a lower unit cost when using AccuCirc compared with Mogen clamp. To minimize unit costs, countries planning to scale-up EIMC using AccuCirc need to control costs of consumables and personnel. There is also need to negotiate a reasonable device price and maximize capacity utilization.

  4. CircRNA-0004904, CircRNA-0001855, and PAPP-A: Potential Novel Biomarkers for the Prediction of Preeclampsia

    Directory of Open Access Journals (Sweden)

    Min Jiang

    2018-05-01

    Full Text Available Background/Aims: Circular RNAs (circRNAs are transcribed prevalently in the genome; however, their potential roles in multiple cardiovascular diseases, particularly preeclampsia (PE, are not yet well understood. This study investigated the expression profiles of circRNAs and explored circRNA-mediated pregnancy-associated plasma protein A (PAPP-A expression as a potential biomarker for PE before 20 weeks of pregnancy. Methods: A nested case-control two-phase screening/validation study was performed in pregnant women before 20 weeks of gestation (before clinical diagnosis at Guangzhou Women and Children’s Medical Center from 2012 to 2015. In the screening phase, circRNA expression profiles of blood cells were assessed using a human circRNA microarray, which was designed to detect simultaneously 5396 circRNAs, in 5 patients with PE and 5 age- and gestational week-matched controls. In the validation phase, 18 circRNAs in blood cells predicted by bioinformatics tools were validated by quantitative reverse transcription PCR in a cohort of 60 patients (PE and age-, gestational week-, and sample storage time-matched controls. Then, we examined the involvement of circRNAs in PE-related pathways via interactions with miRNAs by multiple bioinformatics approaches. Bioinformatics analysis predicted that hsa_circ_0004904 and hsa_circ_0001855 miRNA sponges directly target PAPP-A. PAPP-A was verified in the serum of the same cohort of patients using an enzyme-linked immunosorbent assay. Finally, we combined PAPP-A with circRNAs to create a novel preclinical diagnostic model for PE with logistic regression and evaluated the efficiency of this model with receiver operating curve analysis. Results: Volcano plot analysis using various parameters showed that circRNAs were differentially expressed among both groups (P < 0.01, fold change > 2. In the screening phase, we found that 2178 circRNAs were differentially expressed between the control and PE groups, in

  5. Reduced expression of circRNA hsa_circ_0003159 in gastric cancer and its clinical significance.

    Science.gov (United States)

    Tian, Mengqian; Chen, Ruoyu; Li, Tianwen; Xiao, Bingxiu

    2018-03-01

    Circular RNAs (circRNAs) play a crucial role in the occurrence of several diseases including cancers. However, little is known about circRNAs' diagnostic values for gastric cancer, one of the worldwide most common diseases of mortality. The hsa_circ_0003159 levels in 108 paired gastric cancer tissues and adjacent non-tumorous tissues from surgical patients with gastric cancer were first detected by real-time quantitative reverse transcription-polymerase chain reaction. Then, the relationships between hsa_circ_0003159 expression levels in gastric cancer tissues and the clinicopathological factors of patients with gastric cancer were analyzed. Finally, its diagnostic value was evaluated through the receiver operating characteristic curve. Compared with paired adjacent non-tumorous tissues, hsa_circ_0003159 expression was significantly down-regulated in gastric cancer tissues. What is more, we found that hsa_circ_0003159 expression levels were significantly negatively associated with gender, distal metastasis, and tumor-node-metastasis stage. All of the results suggest that hsa_circ_0003159 may be a potential cancer marker of patients with gastric cancer. © 2017 Wiley Periodicals, Inc.

  6. Genome-Wide Identification of circRNAs in Pathogenic Basidiomycetous Yeast Cryptococcus neoformans Suggests Conserved circRNA Host Genes over Kingdoms

    Directory of Open Access Journals (Sweden)

    Liang Huo

    2018-02-01

    Full Text Available Circular RNAs (circRNAs, a novel class of ubiquitous and intriguing noncoding RNA, have been found in a number of eukaryotes but not yet basidiomycetes. In this study, we identified 73 circRNAs from 39.28 million filtered RNA reads from the basidiomycete Cryptococcus neoformans JEC21 using next-generation sequencing (NGS and the bioinformatics tool circular RNA identification (CIRI. Furthermore, mapping of newly found circRNAs to the genome showed that 73.97% of the circRNAs originated from exonic regions, whereas 20.55% were from intergenic regions and 5.48% were from intronic regions. Enrichment analysis of circRNA host genes was conducted based on the Gene Ontology and Kyoto Encyclopedia of Genes and Genomes pathway databases. The results reveal that host genes are mainly responsible for primary metabolism and, interestingly, ribosomal protein production. Furthermore, we uncovered a high-level circRNA that was a transcript from the guanosine triphosphate (GTPase gene CNM01190 (gene ID: 3255052 in our yeast. Coincidentally, YPT5, CNM01190′s ortholog of the GTPase in Schizosaccharomyces pombe, protists, and humans, has already been proven to generate circRNAs. Additionally, overexpression of RNA debranching enzyme DBR1 had varied influence on the expression of circRNAs, indicating that multiple circRNA biosynthesis pathways exist in C. neoformans. Our study provides evidence for the existence of stable circRNAs in the opportunistic human pathogen C. neoformans and raises a question regarding their role related to pathogenesis in this yeast.

  7. CIRCE, the Coherent Infrared Center at the ALS

    International Nuclear Information System (INIS)

    Byrd, John M.; De Santis, Stefano; Jung, Jin-Young; Li, Derun; Martin, Michael C.; McKinney, W.; Munson, Dawn; Nishimura, Hiroshi; Robin, David S.; Sannibale, Fernando; Schlueter, Ross; Venturini, Marco; Wan, Weishi; Zolotorev, Max

    2004-01-01

    CIRCE (Coherent InfraRed CEnter) is a proposal for a new electron storage ring to be built at the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory (LBNL). The ring design is optimized for the generation of coherent synchrotron radiation (CSR) in the terahertz frequency range. Among others, CIRCE operation includes three interesting CSR modes: ultra stable, femtosecond laser slicing and broadband bursting. CSR allows CIRCE to generate an extremely high flux in the terahertz frequency region. The many orders of magnitude increase in the intensity over that presently achievable by conventional sources, has the potential to enable new science experiments. The characteristics of CIRCE and of the different modes of operation are described in this paper

  8. Correlation of circRNAs’ differential expression to negative- positive symptoms of patients with schizophrenia

    Directory of Open Access Journals (Sweden)

    Ling-ming KONG

    2017-11-01

    Full Text Available Objective To explore the correlation of circRNAs' expression level to the negative- and positive symptoms of patients with schizophrenia (SZ. Methods Gene chip screening was performed with the peripheral blood samples from each five of SZ patients and normal controls. Nine circRNAs showing differentiate expression were confirmed, and further verification was done by real-time fluorescence quantitative PCR in 102 SZ patients and 103 normal controls. All the SZ patients were assessed with Positive and Negative Symptom Scale (PANSS. Results It was revealed that the expression levels of circRNA_102101, circRNA_102315, circRNA_104597, circRNA_101835 and circRNA_101836 were significantly down-regulated (P<0.01 or P<0.05, and circRNA_103102 and circRNA_103704 were up-regulated in SZ group (P<0.01. The ΔCT value of circRNA_102101 and circRNA_103102 was positively correlated to the positive symptoms (P<0.01 or P<0.05, and the ΔCT value of circRNA_103704 also showed positive correlation with positive symptoms and general psychopathological symptoms (P<0.01 or P<0.05. The ΔCT values of circRNA_102101, circRNA_103102, circRNA_102315, circRNA_103704 and circRNA_102802 were correlated with thinking disorder (P<0.01 or P<0.05, and the ΔCT values of circRNA_102101, circRNA_103102, circRNA_104597, circRNA_103704 and circRNA_102802 were correlated with the activation (P<0.01 or P<0.05. The ΔCT values of circRNA_102101, circRNA_103102, circRNA_103704 and circRNA_102802 were positively correlated with paranoid (P<0.01 or P<0.05, and of circRNA_102101, circRNA_103102, circRNA_103704 and circRNA_102802 were markedly correlated with assault (P<0.01 or P<0.05. Therefore, circRNA_103704 was chosen into regressive equation of positive symptoms (P<0.01, and circRNA_103704 and circRNA_102315 were chosen into regressive equation of general pathological findings (P<0.01 or P<0.05. Conclusion The expression levels of circRNA_103704 and circRNA_103102 are obviously up

  9. A Study on Uncertainty Quantification of Reflood Model using CIRCE Methodology

    International Nuclear Information System (INIS)

    Jeon, Seongsu; Hong, Soonjoon; Oh, Deogyeon; Bang, Youngseok

    2013-01-01

    The CIRCE method is intended to quantify the uncertainties of the correlations of a code. It may replace the expert judgment generally used. In this study, an uncertainty quantification of reflood model was performed using CIRCE methodology. In this paper, the application process of CIRCE methodology and main results are briefly described. This research is expected to be useful to improve the present audit calculation methodology, KINS-REM. In this study, an uncertainty quantification of reflood model was performed using CIRCE methodology. The application of CIRCE provided the satisfactory results. This research is expected to be useful to improve the present audit calculation methodology, KINS-REM

  10. Corrosion behavior of austenitic and ferritic/martensitic steels in oxygen-saturated liquid Pb-Bi eutectic at 450circC and 550circC

    OpenAIRE

    倉田 有司; 二川 正敏; 斎藤 滋

    2005-01-01

    Static corrosion tests of various austenitic and ferritic/martensitic steels were conducted in oxygen-saturated liquid Pb-Bi at 450circC and 550circC for 3000h to study the effects of temperature and alloying elements on corrosion behavior. Oxidation, grain boundary corrosion, dissolution and penetration were observed. The corrosion depth decreases at 450circC with increasing Cr content in steels regardless of ferritic/martensitic or austenitic steels. Appreciable dissolution of Ni and Cr doe...

  11. Expression of hsa_circ_PVT1 in human hepatocellular carcinoma and its clinical significance

    Directory of Open Access Journals (Sweden)

    Yuan-xin ZHU

    2018-03-01

    Full Text Available Objective To determine the expression and clinical significance of circ-PVT1 in human hepatocellular carcinoma (HCC and its effect on HCC cell proliferation. Methods The expressions of circ-PVT1 in hepatocellular carcinoma and the matched tumor-adjacent tissues were detected by RT-qPCR and the relationship between pathological indexes and the expression level was analyzed in 46 patients. The expressions of circ-PVT1 in human normal liver cell line (L02 and hepatocellular carcinoma cell lines (HepG2, SMMC-7721, MHCC-97H, MHCC-97L, HCC-LM3 were detected by RT-qPCR and were compared thereafter. With knocking down the expression of circ-PVT1, si-circPVT1 was transfected into HepG2 and SMMC-7721 cells by using lipofectamine technique in vitro, with the si-NC being taken as negative control. After interfering the expression of circ-PVT1, the effect on the proliferation of hepatocellular carcinoma cells was detected by CCK-8 and EDU experiments and flow cytometry was conducted to observe the effect of circ-PVT1 on cell cycle. Results The expression level of circ-PVT1 was significantly higher in HCC tissues than in adjacent tissues (P<0.01, and its high expression level was significantly correlated with tumor size, TNM stage and differentiation degree. Similarly, in human hepatocellular carcinoma cell lines (HepG2, SMMC-7721, MHCC-97H, MHCC-97L, HCC-LM3, the expression level of circ-PVT1 was also higher than that in human normal liver cell line L02 (P<0.05. Compared with the negative control group, silencing of circ-PVT1 resulted in remarkable reduction in cell proliferation of HepG2 and SMMC-7721. Conclusion circ-PVT1 may act as a potential biomarker for HCC diagnosis and may become a novel proliferation factor. DOI: 10.11855/j.issn.0577-7402.2018.03.06

  12. Integrative analysis of circRNAs acting as ceRNAs involved in ethylene pathway in tomato.

    Science.gov (United States)

    Wang, Yunxiang; Wang, Qing; Gao, Lipu; Zhu, Benzhong; Luo, Yunbo; Deng, Zhiping; Zuo, Jinhua

    2017-11-01

    Circular RNAs (circRNAs) are a large class of non-coding endogenous RNAs that could act as competing endogenous RNAs (ceRNAs) to terminate the mRNA targets' suppression of miRNAs. To elucidate the intricate regulatory roles of circRNAs in the ethylene pathway in tomato fruit, deep sequencing and bioinformatics methods were performed. After strict screening, a total of 318 circRNAs were identified. Among these circRNAs, 282 were significantly differentially expressed among wild-type and sense-/antisense-LeERF1 transgenic tomato fruits. Besides, 1254 target genes were identified and a large amount of them were found to be involved in ethylene pathway. In addition, a sophisticated regulatory model consisting of circRNAs, target genes and ethylene was set up. Importantly, 61 circRNAs were found to be potential ceRNAs to combine with miRNAs and some of the miRNAs had been revealed to participate in the ethylene signaling pathway. This research further raised the possibility that the ethylene pathway in tomato fruit may be under the regulation of various circRNAs and provided a new perspective of the roles of circRNAs. © 2017 Scandinavian Plant Physiology Society.

  13. CIRCE: A dedicated storage ring for coherent THz synchrotron radiation

    International Nuclear Information System (INIS)

    Byrd, J.M.; Martin, Michael C.; McKinney, W.R.; Munson, D.V.; Nishimura, H.; Robin, D.S.; Sannibale, F.; Schlueter, R.D.; Thur, W.G.; Jung, J.Y.; Wan, W.

    2003-01-01

    We present the concepts for an electron storage ring dedicated to and optimized for the production of stable coherent synchrotron radiation (CSR) over the far-infrared terahertz wavelength range from 200 mm to about one cm. CIRCE (Coherent InfraRed CEnter) will be a 66 m circumference ring located on top of the ALS booster synchrotron shielding tunnel and using the existing ALS injector. This location provides enough floor space for both the CIRCE ring, its required shielding, and numerous beamlines. We briefly outline a model for CSR emission in which a static bunch distortion induced by the synchrotron radiation field is used to significantly extend the stable CSR emission towards higher frequencies. This model has been verified with experimental CSR results. We present the calculated CIRCE photon flux where a gain of 6-9 orders of magnitude is shown compared to existing far-IR sources. Additionally, the particular design of the dipole vacuum chamber has been optimized to allow an excellent transmission of these far-infrared wavelengths. We believe that the CIRCE source can be constructed for a modest cost

  14. Keefektifan Model CIRC Berbasis Joyful Learning Terhadap Kemampuan Penalaran Matematis Siswa SMP

    Directory of Open Access Journals (Sweden)

    Rian Triastuti

    2013-12-01

    Full Text Available AbstrakTujuan penelitian ini adalah untuk mengetahui apakah implementasi model pembelajaran CIRC berbasis Joyfull Learning efektif terhadap kemampuan penalaran matematis siswa pada materi Teorema Pythagoras. Pengumpulan data dilakukan dengan metode dokumen-tasi, tes, dan observasi. Berdasarkan hasil penelitian menunjukkan bahwa siswa pada kelas eksperimen telah mencapai ketuntasan klasikal. Hasil uji perbedaan dua rata-rata menun-jukkan bahwa rata-rata hasil tes kemampuan penalaran matematis siswa kelas eksperimen lebih dari rata-rata hasil tes kemampuan penalaran matematis siswa kelas kontrol. Berdasar-kan hasil tersebut dapat diketahui bahwa rata-rata kemampuan penalaran matematis siswa kelas eksperimen lebih baik daripada rata-rata kemampuan penalaran matematis siswa kelas kontrol. Hasil observasi menunjukkan bahwa persentase keaktifan siswa dalam pelaksanaan pembelajaran CIRC berbasis Joyfull Learning lebih tinggi daripada persentase keaktifan siswa pada pembelajaran ekspositori, dan aktivitas guru dalam mengelola pembelajaran CIRC berbasis Joyfull Learning mencapai kriteria sangat baik. Kata kunci:       CIRC; Joyfull Learning; Kemampuan Penalaran Matematis.  AbstractThe purpose of this study was to determine whether the implementation of the CIRC based Joyful Learning models effective against student’s mathematical reasoning skills on the material Pythagorean Theorem. The population in this study is the eighth grade students of Junior High School of 1 Tlogowungu. Based on the results of the study showed that students in the experimental class have reached the classical completeness. The test results mean the difference of two shows that the average test results of mathematical reasoning skills experimental class students more than the average test results of student’s mathematical reasoning skills control class. Based on these results it can be seen that the average of student’s mathematical reasoning skills experimental

  15. KEMAMPUAN SISWA MENCERITAKAN PENGALAMAN MELALUI MODEL COOPERATIF INTEGREAD READING AND COMPOSITION (CIRC

    Directory of Open Access Journals (Sweden)

    Rahman Rahman

    2018-03-01

    Full Text Available AbstractThis study aims to determine whether Cooperative Integread Reading and Composition (CIRC learning model can improve the students’ ability in telling impressive experiences. The esearcher used classroom action research design with data retrieval method on the test in the form of test. The learning model used is Cooperative Integread Reading and Composition (CIRC. Subjects in this study are the first semester students of class VII, MTs Negeri Sukoharjo academic year 2017/2018 which amounted to 34 students. From the result of data analysis, it is known that telling impressive experience in writing in cycle I obtained the average value of 72,74 and the complete student reaches 64,7% while in cycle II it is obtained the average 80,55 and student complete 100%. Thus the use of appropriate learning model such CIRC can improve students' learning ability in telling the written story.Key Words: Cooperative Integread Reading and Composition (CIRC, written story.

  16. circRNA Mediates Silica-Induced Macrophage Activation Via HECTD1/ZC3H12A-Dependent Ubiquitination

    Science.gov (United States)

    Zhou, Zewei; Jiang, Rong; Yang, Xiyue; Guo, Huifang; Fang, Shencun; Zhang, Yingming; Cheng, Yusi; Wang, Jing; Yao, Honghong; Chao, Jie

    2018-01-01

    Rationale: Phagocytosis of silicon dioxide (SiO2) into lung cells causes an inflammatory cascade that results in fibroblast proliferation and migration, followed by fibrosis. Circular RNAs (circRNAs) are a subclass of non-coding RNAs detected within mammalian cells; however, researchers have not determined whether circRNAs are involved in the pathophysiological process of silicosis. The upstream molecular mechanisms and functional effects on cell apoptosis, proliferation and migration were investigated to elucidate the role of circRNAs in SiO2-induced inflammation in pulmonary macrophages. Methods: Primary cultures of alveolar macrophages from healthy donors and patients as well as the RAW264.7 macrophage cell line were used to explore the functions of circHECTD1 (HECT domain E3 ubiquitin protein ligase 1) in macrophage activation. Results: The results of the experiments indicated that 1) SiO2 concomitantly decreased circHECTD1 levels and increased HECTD1 protein expression; 2) circHECTD1 and HECTD1 were involved in SiO2-induced macrophage activation via ubiquitination; and 3) SiO2-activated macrophages promoted fibroblast proliferation and migration via the circHECTD1/HECTD1 pathway. Tissue samples from silicosis patients confirmed the upregulation of HECTD1. Conclusions: Our study elucidated a link between SiO2-induced macrophage activation and the circHECTD1/HECTD1 pathway, thereby providing new insight into the potential use of HECTD1 in the development of novel therapeutic strategies for treating silicosis. PMID:29290828

  17. circRNA Mediates Silica-Induced Macrophage Activation Via HECTD1/ZC3H12A-Dependent Ubiquitination.

    Science.gov (United States)

    Zhou, Zewei; Jiang, Rong; Yang, Xiyue; Guo, Huifang; Fang, Shencun; Zhang, Yingming; Cheng, Yusi; Wang, Jing; Yao, Honghong; Chao, Jie

    2018-01-01

    Rationale: Phagocytosis of silicon dioxide (SiO 2 ) into lung cells causes an inflammatory cascade that results in fibroblast proliferation and migration, followed by fibrosis. Circular RNAs (circRNAs) are a subclass of non-coding RNAs detected within mammalian cells; however, researchers have not determined whether circRNAs are involved in the pathophysiological process of silicosis. The upstream molecular mechanisms and functional effects on cell apoptosis, proliferation and migration were investigated to elucidate the role of circRNAs in SiO 2 -induced inflammation in pulmonary macrophages. Methods: Primary cultures of alveolar macrophages from healthy donors and patients as well as the RAW264.7 macrophage cell line were used to explore the functions of circHECTD1 (HECT domain E3 ubiquitin protein ligase 1) in macrophage activation. Results: The results of the experiments indicated that 1) SiO 2 concomitantly decreased circHECTD1 levels and increased HECTD1 protein expression; 2) circHECTD1 and HECTD1 were involved in SiO 2 -induced macrophage activation via ubiquitination; and 3) SiO 2 -activated macrophages promoted fibroblast proliferation and migration via the circHECTD1/HECTD1 pathway. Tissue samples from silicosis patients confirmed the upregulation of HECTD1. Conclusions: Our study elucidated a link between SiO 2 -induced macrophage activation and the circHECTD1/HECTD1 pathway, thereby providing new insight into the potential use of HECTD1 in the development of novel therapeutic strategies for treating silicosis.

  18. PENERAPAN MODEL PEMBELAJARAN TIPE CIRC UNTUK MENINGKATKAN HASIL BELAJAR MATEMATIKA

    Directory of Open Access Journals (Sweden)

    Lina Salantina

    2018-01-01

    Full Text Available Keberhasilan belajar matematika, salah satunya ditentukan oleh minat siswa, dan untuk membangkitkan minat siswa tersebut ditentukan oleh kemampuan guru dalam menggunakan pendekatan mengajarnya yang dapat mengakibatkan siswa lebih tertarik, mengerti, berperan serta aktif, mencari dan menemukan sendiri. Untuk bahan penelitian, pokok bahasan yang diambil adalah perbandingan senilai (seharga dan perbandingan berbalik nilai (berbalik harga. Dengan menerapkan model pembelajaran Cooperative Learning tipe Cooperative Integrated Reading and Composition (CIRC,ternyata hasil belajar dapat meningkat bila dibandingkan dengan hasil belajar sebelumnya.Hal ini diduga karena guru kurang tepat dalam mengambil model pembelajaran untuk materi tersebut. Permasalahan yang diangkat pada penelitian ini adalah apakah penggunaan model pembelajaran Cooperative Learning Tipe Cooperative Integrated Reading And Composition (CIRC dapat meningkatkan hasil belajar siswa pada pokok bahasan perbandingan. Subyek penelitian ini adalah siswa kelas VII B SMP Negeri 3 Kuningan tahun pelajaran 2015/2016, dengan jumlah siswa 40 orang yang terdiri dari 18 siswa putri, dan 22 siswa putra. Prosedur tindakan kelas ini ditempuh dalam 3 siklus. Langkah-langkah siklus terdiri dari perencanaan, tindakan, pengamatan, dan refleksi. Cara pengambilan data dalam penelitian ini dengan menggunakan tes, penilaian kinerja, dan observasi. Sebagai tolok ukur keberhasilan adalah nilai rata-rata silkus I, II, dan III berturut-turut 63,4, 63,0, 65,6 dan ketuntasan belajar klasikal berturut-turut 72,5%, 67,5%, dan 80,0%. Simpulan yang dapat peneliti ambil adalah penggunaan Model Pembelajaran Cooperative Learning Tipe Cooperative Integrated Reading And Compositon (CIRC dapat meningkatkan hasil belajar. Sedangkan peneliti menyarankan guru hendaknya menggunakan model pembelajaran ini untuk pokok-pokok bahasan perbandingan. Kata kunci: Penerapan Model Pembelajaran Tipe CIRC.

  19. Hot-electron-plasma accumulation in the CIRCE mirror experiment

    International Nuclear Information System (INIS)

    Bardet, R.; Briand, P.; Dupas, L.; Gormezano, C.; Melin, G.

    1975-01-01

    In the CIRCE experiment, the plasma is obtained by the trapping of a plasma injected into a magnetic bottle by electron heating at cyclotron resonance. The plasma density lies between 5x10 11 cm -3 and 10 12 cm -3 , the electron temperature is about 100 keV and the ion temperature is in the range of few hundred electronvolts. Gross instabilities are not observed. The ratio of the plasma density to the neutral-gas density inside the plasma is higher than 100. A few kilowatts of r.f. power at 8 GHz are sufficient to obtain these results, a fact which looks encouraging as far as the creation of a more effective fast-neutral-target plasma using the CIRCE-experiment concept is concerned. (author)

  20. Regional assessment of Climate change impacts in the Mediterranean: the CIRCE project

    Science.gov (United States)

    Iglesias, A.

    2011-12-01

    The CIRCE project has developed for the first time an assessment of the climate change impacts in the Mediterranean area. The objectives of the project are: to predict and to quantify physical impacts of climate change in the Mediterranean area; to evaluate the consequences of climate change for the society and the economy of the populations located in the Mediterranean area; to develop an integrated approach to understand combined effects of climate change; and to identify adaptation and mitigation strategies in collaboration with regional stakeholders. The CIRCE Project, coordinated by the Instituto Nazionale di Geofisca e Vulcanologia, started on 1st April 2007 and ended in a policy conference in Rome on June 2011. CIRCE involves 64 partners from Europe, Middle East and North Africa working together to evaluate the best strategies of adaptation to the climate change in the Mediterranean basin. CIRCE wants to understand and to explain how climate will change in the Mediterranean area bringing together the natural sciences community and social community in a new integrated and comprehensive way. The project has investigated how global and Mediterranean climates interact, how the radiative properties of the atmosphere and the radiative fluxes vary, the interaction between cloudiness and aerosol, the modifications in the water cycle. Recent observed modifications in the climate variables and detected trends will be compared. The economic and social consequences of climate change are evaluated by analysing direct impacts on migration, tourism and energy markets together with indirect impacts on the economic system. CIRCE has produced results about the consequences on agriculture, forests and ecosystems, human health and air quality. The variability of extreme events in the future scenario and their impacts is also assessed. A rigorous common framework, including a set of quantitative indicators developed specifically for the Mediterranean environment was be developed

  1. Circular RNA profiling reveals that circCOL3A1-859267 regulate type I collagen expression in photoaged human dermal fibroblasts

    International Nuclear Information System (INIS)

    Peng, Yating; Song, Xiaojing; Zheng, Yue; Wang, Xinyi; Lai, Wei

    2017-01-01

    Production of type I collagen declines is a main characteristic during photoaging, but the mechanism is still not fully understood. Circular RNAs (circRNAs) are a class of newly identified non-coding RNAs with regulatory potency by sequestering miRNAs like a sponge. It's more stable than linear RNAs, and would be a useful tool for regulation of gene expression. However, the role of circRNAs in collagen expression during photoaging is still unclear. Here we performed deep sequencing of RNA generated from UVA irradiated and no irradiated human dermal fibroblasts (HDFs) and identified 29 significantly differentially expressed circRNAs (fold change ≥ 1.5, P < 0.05), 12 circRNAs were up-regulated and 17 circRNAs were down-regulated.3 most differentially expressed circRNAs were verified by qRT-PCR and the down-regulated circCOL3A1-859267 exhibited the most significantly altered in photoaged HDFs. Overexpression of circCOL3A1-859267 inhibited UVA-induced decrease of type I collagen expression and silencing of it reduced type I collagen intensity. Via a bioinformatic method, 44 miRNAs were predicted to binding with circCOL3A1-859267, 5 of them have been confirmed or predicted to interact with type I collagen. This study show that circCOL3A1-859267 regulate type I collagen expression in photoaged HDFs, suggesting it may be a novel target for interfering photoaging.

  2. The Potential Role of circRNA in Tumor Immunity Regulation and Immunotherapy

    OpenAIRE

    Xu, Zihao; Li, Peiyao; Fan, Li; Wu, Minghua

    2018-01-01

    Non-coding RNAs (ncRNAs) can be divided into circular non-coding RNAs (circRNAs) and linear ncRNAs. ncRNAs exist in different cell types, including normal cells, tumor cells and immunocytes. Linear ncRNAs, such as long ncRNAs and microRNAs, have been found to play important roles in the regulation of tumor immunity and immunotherapy; however, the functions of circRNAs in tumor immunity and immunotherapy are less known. Here, we review the current status of ncRNAs in the regulation of tumor im...

  3. Hsa_circ_0054633 in peripheral blood can be used as a diagnostic biomarker of pre-diabetes and type 2 diabetes mellitus.

    Science.gov (United States)

    Zhao, Zhenzhou; Li, Xuejie; Jian, Dongdong; Hao, Peiyuan; Rao, Lixin; Li, Muwei

    2017-03-01

    The purpose of the current study was to investigate the characteristic expression of circular RNAs (circRNAs) in the peripheral blood of type 2 diabetes mellitus (T2DM) patients and their potential as diagnostic biomarkers for pre-diabetes and T2DM. CircRNAs in the peripheral blood from six healthy individuals and six T2DM patients were collected for microarray analysis, and an independent cohort study consisting of 20 normal cases, 20 pre-diabetes patients and 20 T2DM patients was conducted to verify the five chosen circRNAs. We then tested hsa_circ_0054633 in a third cohort (control group, n = 60; pre-diabetes group, n = 63; and T2DM group, n = 64) by quantitative real-time polymerase chain reaction (Q-PCR). In total, 489 circRNAs were discovered to be differentially expressed between the two groups, and of these, 78 were upregulated and 411 were downregulated in the T2DM group. Five circRNAs were then selected as candidate biomarkers and further verified in a second cohort. Hsa_circ_0054633 was found to have the largest area under the curve (AUC). The diagnostic capacity of hsa_circ_0054633 was tested in a third cohort. After introducing the risk factors of T2DM, the hsa_circ_0054633 AUCs for the diagnosis of pre-diabetes and T2DM slightly increased from 0.751 (95% confidence interval [0.666-0.835], P diabetes and T2DM.

  4. Genome-Wide Maps of m6A circRNAs Identify Widespread and Cell-Type-Specific Methylation Patterns that Are Distinct from mRNAs

    Directory of Open Access Journals (Sweden)

    Chan Zhou

    2017-08-01

    Full Text Available N6-methyladenosine (m6A is the most abundant internal modification of mRNAs and is implicated in all aspects of post-transcriptional RNA metabolism. However, little is known about m6A modifications to circular (circ RNAs. We developed a computational pipeline (AutoCirc that, together with depletion of ribosomal RNA and m6A immunoprecipitation, defined thousands of m6A circRNAs with cell-type-specific expression. The presence of m6A circRNAs is corroborated by interaction between circRNAs and YTHDF1/YTHDF2, proteins that read m6A sites in mRNAs, and by reduced m6A levels upon depletion of METTL3, the m6A writer. Despite sharing m6A readers and writers, m6A circRNAs are frequently derived from exons that are not methylated in mRNAs, whereas mRNAs that are methylated on the same exons that compose m6A circRNAs exhibit less stability in a process regulated by YTHDF2. These results expand our understanding of the breadth of m6A modifications and uncover regulation of circRNAs through m6A modification.

  5. Studi Perbedaan Keefektifan Pembelajaran LC-5E dan CIRC Terhadap Kemampuan Pemecahan Masalah Matematika

    Directory of Open Access Journals (Sweden)

    E. Sulastri

    2015-06-01

    Full Text Available membandingkan keefektifan model pembelajaran kooperatif tipe LC-5E (Learning Cycle 5E dan tipe CIRC(Cooperative Integrated Reading and Composition terhadap kemampuan pemecahan masalah matematika peserta didik. Populasi penelitian adalah peserta didik kelas X SMA Negeri 2 Ungaran. Sampel diambil secara cluster random sampling. Data akhir mengenai kemampuan pemecahan masalah diambil menggunakan metode tes. Teknik analisis data menggunakan uji proporsi, uji Anava dan uji lanjut LSD. Hasil penelitian menunjukkan kelas yang dikenai perlakuan pembelajaran LC-5Edan CIRCmencapai ketuntasan belajar. Dari uji Anava diketahui bahwa ada perbedaan rata-rata yang signifikan. Selanjutnya dilakukan uji lanjut LSDmenunjukkan Kelompok Eksperimen 1 paling baik. Simpulan dari penelitian ini adalah model pembelajaran LC-5Elebih efektif dibandingkan tipe CIRC terhadap kemampuan pemecahan masalah peserta didik. Saran yang dapat direkomendasikan adalah pembelajaran LC-5E dapat digunakan sebagai alternatif dalam mengembangkan kemampuan pemecahan masalah peserta didik. The purpose of this research was tocomparethe effectiveness of cooperative learning models type LC-5E (Learning Cycle 5E and type CIRC (Cooperative Integrated Reading and Composition toward students’ mathematic problem solving ability. The population of this research was students grade X of SMA Negeri 2 Ungaran.The samples were taken by cluster random sampling. The final data about students’ problem solving ability were taken used test method. Data were analysed used propotion test, ANOVA test, and LSD test. The result shown that classes that given LC-5E and CIRC learning models achieved mastery learning. From ANOVA test known that the averages are different significantly.From LSD test is known that the experiment group was the best. The conclusions from this research are LC-5E is more effective than CIRC learning model toward students’ problem solving ability. The suggestion is LC-5E model can be

  6. Circe: a tool for calculating the uncertainties of the constitutive relationships of Cathare 2

    International Nuclear Information System (INIS)

    Crecy, A. de

    1997-01-01

    This paper presents Circe, a methodology for determining the uncertainties of the constitutive relationships in Cathare 2 code. It is a compulsory step for calculating the final uncertainty of a given response, or in other words for performing any uncertainty analysis. First, the general principles of Circe are explained. The problem is rather difficult because the constitutive relationships (also called correlations) cannot be directly measured in experiments used to establish them. The results of these experiments are consequently considered to obtain information about the correlations. More precisely, a statistical approach is used, combining the differences between code and experiment results. The uncertainties are given in the form of a covariance matrix of the parameters associated with the correlations. The application of Circe to three correlations and three experiments is then presented. Although there is not a one-to-one correspondance between correlations and experiments, the application was successfully performed. Finally, two improvements to Circe are presented. The first one deals with bias calculation. Biases concerning the correlations can be suspected when there is a systematic shift of the calculated results with respect to the experimental ones. Taking them into account makes it possible to improve code results. The second one deals with the calculation of the accuracy of the terms of the calculated covariance matrix, using a bootstrap technique. (author)

  7. Prototype CIRCE plant - industrial demonstration of heavy water production from reformed hydrogen source

    International Nuclear Information System (INIS)

    Spagnolo, D.A.; Boniface, H.A.; Sadhankar, R.R.; Everatt, A.E.; Miller, A.I.; Blouin, J.

    2002-01-01

    Heavy water (D 2 0) production has been dominated by the Girdler-Sulphide (G-S) process, which suffers several intrinsic disadvantages that lead to high production costs. Processes based on hydrogen/water exchange have become more attractive with the development of proprietary wetproofed catalysts by AECL. One process that is synergistic with industrial hydrogen production by steam methane reforming (SMR), the Combined Industrial Reforming and Catalytic Exchange (CIRCE) process, offers the best prospect for commercialization. SMRs are common globally in the oil-upgrading and ammonia industries. To study the CIRCE process in detail, AECL, in collaboration with Air Liquide Canada, constructed a prototype CIRCE plant (PCP) in Hamilton, Ontario. The plant became fully operational in 2000 July and is expected to operate to at least late fall of 2002. To-date, plant operation has confirmed the adequacy of the design and the capability of enriching deuterium to produce heavy water without compromising hydrogen production. The proprietary wetproofed catalyst has performed as expected, both in activity and in robustness. (author)

  8. CircSMARCA5 Inhibits Migration of Glioblastoma Multiforme Cells by Regulating a Molecular Axis Involving Splicing Factors SRSF1/SRSF3/PTB

    Directory of Open Access Journals (Sweden)

    Davide Barbagallo

    2018-02-01

    Full Text Available Circular RNAs (circRNAs have recently emerged as a new class of RNAs, highly enriched in the brain and very stable within cells, exosomes and body fluids. To analyze their involvement in glioblastoma multiforme (GBM pathogenesis, we assayed the expression of twelve circRNAs, physiologically enriched in several regions of the brain, through real-time PCR in a cohort of fifty-six GBM patient biopsies and seven normal brain parenchymas. We focused on hsa_circ_0001445 (circSMARCA5: it was significantly downregulated in GBM biopsies as compared to normal brain tissues (p-value < 0.00001, student’s t-test, contrary to its linear isoform counterpart that did not show any differential expression (p-value = 0.694, student’s t-test. Analysis of a public dataset revealed a negative correlation between the expression of circSMARCA5 and glioma’s histological grade, suggesting its potential negative role in the progression to malignancy. Overexpressing circSMARCA5 in U87MG cells significantly decreased their migration, but not their proliferation rate. In silico scanning of circSMARCA5 sequence revealed an enrichment in binding motifs for several RNA binding proteins (RBPs, specifically involved in splicing. Among them, serine and arginine rich splicing factor 1 (SRSF1, a splicing factor known to be a positive controller of cell migration and known to be overexpressed in GBM, was predicted to bind circSMARCA5 by three different prediction tools. Direct interaction between circSMARCA5 and SRSF1 is supported by enhanced UV crosslinking and immunoprecipitation (eCLIP data for SRSF1 in K562 cells from Encyclopedia of DNA Elements (ENCODE. Consistently, U87MG overexpressing circSMARCA5 showed an increased expression of serine and arginine rich splicing factor 3 (SRSF3 RNA isoform containing exon 4, normally skipped in a SRSF1-dependent manner, resulting in a non-productive non-sense mediated decay (NMD substrate. Interestingly, SRSF3 is known to interplay

  9. Prototype CIRCE plant-industrial demonstration of heavy-water production from a reformed hydrogen source

    Energy Technology Data Exchange (ETDEWEB)

    Spagnolo, D.A.; Boniface, H.A.; Sadhankar, R.R.; Everatt, A.E.; Miller, A.I. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Blouin, J. [Air Liquide Canada, Hamilton, Ontario (Canada)

    2002-09-01

    Heavy-water (D{sub 2}0) production has been dominated by the Girdler-Sulphide (G-S) process, which suffers several intrinsic disadvantages that lead to high production costs. Processes based on hydrogen/water exchange have become more attractive with the development of proprietary wetproofed catalysts by AECL. One process that is synergistic with industrial hydrogen production by steam methane reforming (SMR), the combined industrial reforming and catalytic exchange (CIRCE) process, offers the best prospect for commercialization. SMRs are common globally in the oil upgrading and ammonia industries. To study the CIRCE process in detail, AECL, in collaboration with Air Liquide Canada, constructed a prototype CIRCE plant (PCP) in Hamilton, ON. The plant became fully operational in 2000 July and is expected to operate to at least the late fall of 2002. To date, plant operation has confirmed the adequacy of the design and the capability of enriching deuterium to produce heavy water without compromising hydrogen production. The proprietary wetproofed catalyst has performed as expected, both in activity and in robustness. (author)

  10. Prototype CIRCE plant-industrial demonstration of heavy-water production from a reformed hydrogen source

    International Nuclear Information System (INIS)

    Spagnolo, D.A.; Boniface, H.A.; Sadhankar, R.R.; Everatt, A.E.; Miller, A.I.; Blouin, J.

    2002-09-01

    Heavy-water (D 2 0) production has been dominated by the Girdler-Sulphide (G-S) process, which suffers several intrinsic disadvantages that lead to high production costs. Processes based on hydrogen/water exchange have become more attractive with the development of proprietary wetproofed catalysts by AECL. One process that is synergistic with industrial hydrogen production by steam methane reforming (SMR), the combined industrial reforming and catalytic exchange (CIRCE) process, offers the best prospect for commercialization. SMRs are common globally in the oil upgrading and ammonia industries. To study the CIRCE process in detail, AECL, in collaboration with Air Liquide Canada, constructed a prototype CIRCE plant (PCP) in Hamilton, ON. The plant became fully operational in 2000 July and is expected to operate to at least the late fall of 2002. To date, plant operation has confirmed the adequacy of the design and the capability of enriching deuterium to produce heavy water without compromising hydrogen production. The proprietary wetproofed catalyst has performed as expected, both in activity and in robustness. (author)

  11. Pengaruh Model Pembelajaran Kooperatif Tipe Cooperative Integrated Reading And Composition (CIRC Bermuatan Nilai Karakter terhadap Kemampuan Menulis Cerpen Siswa Kelas VII

    Directory of Open Access Journals (Sweden)

    Mhd. Jasri Ilham

    2017-03-01

    Full Text Available Abstract: This study aimed at investigating the effect of cooperative learning of CIRC type with character values on short story seventh graders’ writing achievement at junior high school. In addition to that, a quantitative method with a quasi experimental design (pretest-posttest control group design was conducted. It turned out that there was a significant effect of using cooperative learning of CIRC type with character values on short story seventh graders’ writing achievement at State Senior High School 5 Muara Bungo in (1 developing theme (3,383 e” 2,0086, (2 using the language (2,533 e” 2,0086, (3 developing the background (2,469 e” 2,0086, (4 developing characters (2,319 e” 2,0086, (5 developing the plot (2,087 e” 2,0086, and (6 implementing character values in cooperative learning of CIRC type in writing short story ran well. The finding was corroborated by the mean of students’ character values (3,16 and was categorized as good. Key Words: writing learning, short story, CIRC cooperative learning, character value Abstrak: Tujuan penulisan artikel ini untuk mendeskripsikan pengaruh model pembelajaran kooperatif tipe CIRC bermuatan nilai karakter terhadap kemampuan menulis cerpen siswa kelas VII SMP. Metode yang digunakan adalah metode kuantitatif dengan rancangan kuasi eksperimen (quasi experimental dengan desain pretest-posttest control group design. Hasil penelitian menunjukkan bahwa, terdapat pengaruh yang signifikan penggunaan model pembelajaran kooperatif tipe CIRC bermuatan nilai karakter terhadap kemampuan menulis cerpen siswa kelas VII SMPN 5 Muara Bungo; dalam (1 mengembangkan tema (3,383 e” 2,0086, (2 menggunakan bahasa (2,533 e” 2,0086, (3 mengembangkan latar (2,469 e” 2,0086, (4 mengembangkan penokohan (2,319 e” 2,0086, (5 mengembangkan alur (2,087 e” 2,0086, dan (6 pengimplentasian nilai karakter dalam pembelajaran kooperatif tipe CIRC dalam menulis cerpen terlaksana dengan baik. Hal ini terbuktikan

  12. Comprehensive profile of differentially expressed circular RNAs reveals that hsa_circ_0000069 is upregulated and promotes cell proliferation, migration, and invasion in colorectal cancer

    Directory of Open Access Journals (Sweden)

    Guo J

    2016-12-01

    Full Text Available Jia-ni Guo,* Jin Li,* Chang-li Zhu,* Wan-ting Feng, Jing-xian Shao, Li Wan, Ming-de Huang, Jing-dong He Department of Medical Oncology, Huai’an First People’s Hospital, Nanjing Medical University, Huai’an City, Jiangsu Province, People’s Republic of China *These authors contributed equally to this work Background: Nowadays, despite great progress in cancer research, the detailed mechanisms of colorectal cancer (CRC are still poorly understood. Circular RNAs (circRNAs, a new star of the non-coding RNA network, have been identified as critical regulators in various cancers, including CRC. Methods and results: In this study, by using unsupervised hierarchical clustering analysis, a novel dysregulated circRNA, hsa_circ_0000069, was found. The expression of hsa_circ_0000069 was measured in 30 paired CRC tissues and adjacent noncancerous tissues using quantitative polymerase chain reaction. A high expression of hsa_circ_0000069 was observed in CRC tissues and correlated with patients’ age and tumor, node, metastasis (TNM stage (P<0.05. Furthermore, by using specifically designed siRNAs in CRC cells, a functional analysis was performed which revealed that hsa_circ_0000069 knockdown could notably inhibit cell proliferation, migration, and invasion, and induce G0/G1 phase arrest of cell cycle in vitro. Conclusion: This study’s findings are the first to demonstrate that hsa_circ_0000069, an important regulator in cancer progression, could be a promising target in the diagnosis and therapy in colorectal cancer. Keywords: circular RNA, colorectal cancer, regulation, hsa_circ_0000069

  13. circHECTD1 promotes the silica-induced pulmonary endothelial-mesenchymal transition via HECTD1.

    Science.gov (United States)

    Fang, Shencun; Guo, Huifang; Cheng, Yusi; Zhou, Zewei; Zhang, Wei; Han, Bing; Luo, Wei; Wang, Jing; Xie, Weiping; Chao, Jie

    2018-03-14

    Excessive proliferation and migration of fibroblasts contribute to pulmonary fibrosis in silicosis, and both epithelial cells and endothelial cells participate in the accumulation of fibroblasts via the epithelial-mesenchymal transition (EMT) and the endothelial-mesenchymal transition (EndMT), respectively. A mouse endothelial cell line (MML1) was exposed to silicon dioxide (SiO 2 , 50 μg/cm 2 ), and immunofluorescence and western blot analyses were performed to evaluate levels of specific endothelial and mesenchymal markers and to elucidate the mechanisms by which SiO 2 induces the EndMT. Functional changes were evaluated by analyzing cell migration and proliferation. The mRNA and circular RNA (circRNA) levels were measured using qPCR and fluorescent in situ hybridization (FISH). Lung tissue samples from both Tie2-GFP mice exposed to SiO 2 and silicosis patients were applied to confirm the observations from in vitro experiments. Based on the results from the current study, SiO 2 increased the expression of mesenchymal markers (type I collagen (COL1A1), type III collagen (COL3A1) and alpha smooth muscle actin (α-SMA/Acta2)) and decreased the expression of endothelial markers (vascular endothelial cadherin (VE-Cad/Cdh 5) and platelet endothelial cell adhesion molecule-1 (PECAM1)), indicating the occurrence of the EndMT in response to SiO 2 exposure both in vivo and in vitro. SiO 2 concomitantly increased circHECTD1 expression, which, in turn, inhibited HECTD1 protein expression. SiO 2 -induced increases in cell proliferation, migration, and changes in marker levels were restored by either a small interfering RNA (siRNA) targeting circHECTD1 or overexpression of HECTD1 via the CRISPR/Cas9 system, confirming the involvement of the circHECTD1/HECTD1 pathway in the EndMT. Moreover, tissue samples from SiO 2 -exposed mice and silicosis patients confirmed the EndMT and change in HECTD1 expression. Our findings reveal a potentially new function for the circHECTD1/HECTD

  14. Effect of alkylglycerone phosphate synthase on the expression profile of circRNAs in the human thyroid cancer cell line FRO.

    Science.gov (United States)

    Hou, Shasha; Tan, Jian; Yang, Bing; He, Lu; Zhu, Yu

    2018-05-01

    Thyroid cancer is a common primary tumor in China. Therefore, it is important to investigate the underlying molecular mechanism of thyroid cancer in order to achieve effective individualized treatments. In our previous study, a positive correlation between the expression of alkylglycerone phosphate synthase (AGPS) and the malignant phenotype of thyroid cancer cell lines was identified. The inactivation of AGPS was able to decrease the malignancy of cancer, and inhibit tumor growth and invasion. However, the function of AGPS on thyroid cancer was unclear. In the present study, it was revealed that AGPS was able to regulate the expression of circular RNAs (circRNAs), which may be the mechanism of its anticancer activity. Therefore, the effects of AGPS silencing and knockout on circRNA expression in the thyroid cancer cell line FRO were investigated using circRNAs microarray, and Gene Ontology and Kyoto Encyclopedia of Genes and Genomes pathway enrichment analyses were performed in order to investigate the underlying molecular mechanism of AGPS for the regulation of thyroid cancer through circRNAs.

  15. Interconnecting sensors and people to improve the knowledge and sustainable management in rural and alpine environment: the CIRCE project

    Science.gov (United States)

    Cavallo, Eugenio; Biddoccu, Marcella; Bagagiolo, Giorgia; De Marziis, Massimo; Gaia Forni, Emanuela; Alemanno, Laura; Ferraris, Stefano; Canone, Davide; Previati, Maurizio; Turconi, Laura; Arattano, Massimo; Coviello, Velio

    2016-04-01

    Environmental sensor monitoring is continuously developing, both in terms of quantity (i.e. measurement sites), and quality (i.e. technological innovation). Environmental monitoring is carried out by either public or private entities for their own specific purposes, such as scientific research, civil protection, support to industrial and agricultural activities, services for citizens, security, education, and information. However, the acquired dataset could be cross-appealing, hence, being interesting for purposes that diverted from their main intended use. The CIRCE project (Cooperative Internet-of-Data Rural-alpine Community Environment) aimed to gather, manage, use and distribute data obtained from sensors and from people, in a multipurpose approach. The CIRCE project was selected within a call for tender launched by Piedmont Region (in collaboration with CSI Piemonte) in order to improve the digital ecosystem represented by YUCCA, an open source platform oriented to the acquisition, sharing and reuse of data resulting both from real-time and on-demand applications. The partnership of the CIRCE project was made by scientific research bodies (IMAMOTER-CNR, IRPI-CNR, DIST) together with SMEs involved in environmental monitoring and ICT sectors (namely: 3a srl, EnviCons srl, Impresa Verde Cuneo srl, and NetValue srl). Within the project a shared network of agro-meteo-hydrological sensors has been created. Then a platform and its interface for collection, management and distribution of data has been developed. The CIRCE network is currently constituted by a total amount of 171 sensors remotely connected and originally belonging to different networks. They are settled-up in order to monitor and investigate agro-meteo-hydrological processes in different rural and mountain areas of Piedmont Region (NW-Italy), including some very sensitive locations, but difficult to access. Each sensor network differs from each other, in terms of purpose of monitoring, monitored

  16. The Implementation of Cooperative Integrated Reading and Composition (CIRC Method in Teaching Narrative Text to Improve Students’ Reading Comprehension at the Eleventh Grade Students of MAN 2 Model Makassar

    Directory of Open Access Journals (Sweden)

    Darmayanti Darmayanti

    2014-08-01

    Full Text Available This study is aimed to improve the reading comprehension of eleventh grade students at MAN 2 Model Makassar by using CIRC Method. CIRC Method is chosen to practice the communication in the target language. The research problems are: (1. Does the use of CIRC method improve reading comprehension of the eleventh grade students of MAN 2 Model Makassar? (2. Are the students interested in teaching Narrative text through CIRC method of the eleventh grade students of MAN 2 Model Makassar? The objectives of the research were (1 to find out whether or not the use of CIRC method can improve reading comprehension of the eleventh grade students of MAN 2 Model Makassar. (2 to find out the students’ interest toward teaching Narrative text through CIRC method. The research applied Quasi-experimental Design. The population of the research was the Eleventh Grade students of MAN 2 Model Makassar in academic year 2013/2014. The sample was IPS 2 as Experimental Group consisting of 33 students and IPA 2 as Control Group consisting of 37 students, with the total sample 70 students. The researcher used Cluster Random Sampling, two classes of the eleventh grade of MAN 2 Model Makassar were took as the experimental class and the control class. The experimental class taught by using CIRC Method while the control class taught by conventional learning method. The data were collected through reading tests namely Pre test and Post test, that were analyzed by using SPSS 20.0 version. The result of the data showed that there was significant difference between the students’ score who were taught CIRC method and non CIRC method. It proven by the mean score of the experimental group that was higher than control group in the post test. The result of the test indicated that using CIRC method significantly improved the students’ reading comprehension. Then, the questionnaires were analyzed by using Likert Scale that showed the students were interested in learning English

  17. Analyzing the interactions of mRNAs, miRNAs, lncRNAs and circRNAs to predict competing endogenous RNA networks in glioblastoma.

    Science.gov (United States)

    Yuan, Yang; Jiaoming, Li; Xiang, Wang; Yanhui, Liu; Shu, Jiang; Maling, Gou; Qing, Mao

    2018-05-01

    Cross-talk between competitive endogenous RNAs (ceRNAs) may play a critical role in revealing potential mechanisms of tumor development and physiology. Glioblastoma is the most common type of malignant primary brain tumor, and the mechanisms of tumor genesis and development in glioblastoma are unclear. Here, to investigate the role of non-coding RNAs and the ceRNA network in glioblastoma, we performed paired-end RNA sequencing and microarray analyses to obtain the expression profiles of mRNAs, lncRNAs, circRNAs and miRNAs. We identified that the expression of 501 lncRNAs, 1999 mRNAs, 2038 circRNAs and 143 miRNAs were often altered between glioblastoma and matched normal brain tissue. Gene ontology and Kyoto Encyclopedia of Genes and Genomes pathway analyses were performed on these differentially expressed mRNAs and miRNA-mediated target genes of lncRNAs and circRNAs. Furthermore, we used a multi-step computational framework and several bioinformatics methods to construct a ceRNA network combining mRNAs, miRNAs, lncRNAs and circRNA, based on co-expression analysis between the differentially expressed RNAs. We identified that plenty of lncRNAs, CircRNAs and their downstream target genes in the ceRNA network are related to glutamatergic synapse, suggesting that glutamate metabolism is involved in glioma biological functions. Our results will accelerate the understanding of tumorigenesis, cancer progression and even therapeutic targeting in glioblastoma.

  18. CirComPara: A Multi‐Method Comparative  Bioinformatics Pipeline to Detect and Study circRNAs from RNA‐seq Data

    Directory of Open Access Journals (Sweden)

    Enrico Gaffo

    2017-02-01

    Full Text Available Circular RNAs (circRNAs are generated by backsplicing of immature RNA forming covalently closed loops of intron/exon RNA molecules. Pervasiveness, evolutionary conservation, massive and regulated expression, and posttranscriptional regulatory roles of circRNAs in eukaryotes have been appreciated and described only recently. Moreover, being easily detectable disease markers, circRNAs undoubtedly represent a molecular class with high bearing on molecular pathobiology. CircRNAs can be detected from RNAseq data using appropriate computational methods to identify the sequence reads spanning backsplice junctions that do not colinearly map to the reference genome. To this end, several programs were developed and critical assessment of various strategies and tools suggested the combination of at least two methods as good practice to guarantee robust circRNA detection. Here,we present CirComPara (http://github.com/egaffo/CirComPara, an automated bioinformatics pipeline, to detect, quantify and annotate circRNAs from RNAseq data using in parallel four different methods for backsplice identification. CirComPara also provides quantification of linear RNAs and gene expression, ultimately comparing and correlating circRNA and gene/transcript expression level. We applied our method to RNAseqdata of monocyte and macrophage samples in relation to haploinsufficiency of the RNAbinding splicing factor Quaking (QKI. The biological relevance of the results, in terms of number, types and variations of circRNAs expressed, illustrates CirComPara potential to enlarge the knowledge of the transcriptome, adding details on the circRNAome, and facilitating further computational and experimental studies.

  19. Uranium beam characterization at CIRCE for background and contamination determinations.

    Science.gov (United States)

    De Cesare, M; De Cesare, N; D'Onofrio, A; Fifield, L K; Gialanella, L; Terrasi, F

    2015-09-01

    The Accelerator Mass Spectrometry (AMS) is the most sensitive technique, compared either to the Inductively Coupled Plasma (ICP-MS) or Thermal Ionization (TI-MS) mass spectrometer, for the actinide (e.g. (236)U, (x)Pu isotopes) measurements. They are present in environmental samples at the ultra trace level since atmospheric tests of Nuclear Weapons (NWs) performed in the past, deliberate dumping of nuclear waste, nuclear fuel reprocessing, on a large scale, and operation of Nuclear Power Plants (NPPs), on a small scale, have led to the release of a wide range of radioactive nuclides in the environment. At the Center for Isotopic Research on Cultural and Environmental heritage (CIRCE) in Caserta, Italy, an upgraded actinide AMS system, based on a 3-MV pelletron tandem accelerator, has been developed and routinely operated. At CIRCE a charge state distribution as a function of terminal voltage, the beam emittance, measured in the 20° actinides dedicated beam line, as well as the energy and position validation of the U ions were performed in order to determine the best measurement conditions. A (236)U/(238)U isotopic ratio background level of about 5×10(-12) or 3×10(-13), depending on the Time of Flight-Energy (TOF-E) configurations, as well as the spatial distribution of the (235)U, (238)U interferences ions and a (236)U contamination mass of about 0.5 fg have been determined. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Androgen receptor (AR) promotes clear cell renal cell carcinoma (ccRCC) migration and invasion via altering the circHIAT1/miR-195-5p/29a-3p/29c-3p/CDC42 signals.

    Science.gov (United States)

    Wang, Kefeng; Sun, Yin; Tao, Wei; Fei, Xiang; Chang, Chawnshang

    2017-05-28

    Increasing evidence has demonstrated that the androgen receptor (AR) plays important roles to promote the metastasis of clear cell renal cell carcinoma (ccRCC). The detailed mechanisms, especially how AR functions via altering the circular RNAs (circRNAs) remain unclear. Here we identified a new circRNA (named as circHIAT1) whose expression was lower in ccRCCs than adjacent normal tissues. Targeting AR could suppress ccRCC cell progression via increasing circHIAT1 expression. ChIP assay and luciferase assay demonstrated that AR suppressed circHIAT1 expression via regulating its host gene, Hippocampus Abundant Transcript 1 (HIAT1) expression at the transcriptional level. The consequences of AR-suppressed circHIAT1 resulted in deregulating miR-195-5p/29a-3p/29c-3p expressions, which increased CDC42 expression to enhance ccRCC cell migration and invasion. Increasing this newly identified signal via circHIAT1 suppressed AR-enhanced ccRCC cell migration and invasion. Together, these results suggested that circHIAT1 functioned as a metastatic inhibitor to suppress AR-enhanced ccRCC cell migration and invasion. Targeting this newly identified AR-circHIAT1-mediated miR-195-5p/29a-3p/29c-3p/CDC42 signals may help us develop potential new therapies to better suppress ccRCC metastasis. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Advances in bioartificial liver assist devices.

    Science.gov (United States)

    Patzer, J F

    2001-11-01

    Rapid advances in development of bioartificial liver assist devices (BLADs) are exciting clinical interest in the application of BLAD technology for support of patients with acute liver failure. Four devices (Circe Biomedical HepatAssist, Vitagen ELAD, Gerlach BELS, and Excorp Medical BLSS) that rely on hepatocytes cultured in hollow-fiber membrane technology are currently in various stages of clinical evaluation. Several alternative approaches for culture and perfusion of hepatocytes have been evaluated in preclinical, large animal models of liver failure, or at a laboratory scale. Engineering design issues with respect to xenotransplantation, BLAD perfusion, hepatocyte functionality and culture maintenance, and ultimate distribution of a BLAD to a clinical site are delineated.

  2. Evaluating the potential of housekeeping genes, rRNAs, snRNAs, microRNAs and circRNAs as reference genes for the estimation of PMI.

    Science.gov (United States)

    Tu, Chunyan; Du, Tieshuai; Shao, Chengchen; Liu, Zengjia; Li, Liliang; Shen, Yiwen

    2018-04-24

    The precise estimation of postmortem interval (PMI) is a critical step in death investigation of forensic cases. Detecting the degradation of RNA in tissues by real time quantitative polymerase chain reaction (RT-qPCR) technology provides a new theoretical basis for estimation of PMI. However, most commonly used reference genes degrade over time, while previous studies seldom consider this when selecting suitable reference genes for the estimation of PMI. Studies have shown microRNAs (miRNAs) are very stable and circular RNAs (circRNAs) have recently emerged as a novel class of RNAs with high stability. We aimed to evaluate the stability of the two kinds of RNAs and normal reference genes using geNorm and NormFinder algorithms to identify tissue-specific reference genes for PMI estimation. The content of candidate RNAs from mouse heart, liver and skeletal muscle tissues were dynamically examined in 8 consecutive days after death. Among the 11 candidate genes (β-actin, Gapdh, Rps18, 5S, 18S, U6, miR-133a, miR-122, circ-AFF1, LC-Ogdh and LC-LRP6), the following genes showed prioritized stability: miR-122, miR-133a and 18S in heart tissues; LC-Ogdh, circ-AFF1 and miR-122 in liver tissues; and miR-133a, circ-AFF1 and LC-LRP6 in skeletal muscle tissues. Our results suggested that miRNAs and circRNAs were more stable as reference genes than other kinds of RNAs regarding PMI estimation. The appropriate internal control genes were not completely the same across tissue types.

  3. AMS {sup 14}C dating at CIRCE: The Major Temple in Cumae (NA – Italy)

    Energy Technology Data Exchange (ETDEWEB)

    Capano, M., E-mail: capano@cerege.fr [Seconda Università degli Studi di Napoli – CIRCE (Centre for Isotopic Research on Cultural and Environmental Heritage), San Nicola la Strada, CE (Italy); Rescigno, C.; Sirleto, R. [Dipartimento di Lettere e Beni Culturali, Seconda Università degli Studi di Napoli, Santa Maria Capua Vetere, CE (Italy); Passariello, I. [INNOVA-CIRCE, San Nicola la Strada, CE (Italy); Marzaioli, F.; D’Onofrio, A.; Terrasi, F. [INNOVA-CIRCE, San Nicola la Strada, CE (Italy); Dipartimento di Matematica e Fisica, Seconda Università degli Studi di Napoli, Caserta (Italy)

    2015-10-15

    We present here one recent CIRCE (Centre for Isotopic Research on Cultural and Environmental Heritage) – Caserta (Italy) project on cultural heritage field, analysing several mice bones, discovered in the Major Temple on the acropolis of Cumae (Napoli, Southern Italy). The bones were found in a vase linked to the holy context. In order to know their dating and formulate an hypothesis on their presence on the site, if it was an accidental rodent inclusion (believed on the base of archaeological context to have occurred during building abandonment periods (IV–V or XIII centuries AD)) or an intentional and ritual remain, the bones were {sup 14}C dated by AMS at CIRCE. The results indicate that the mice bones date to the IV century BC and are contemporaneous with building construction. This dating seems to exclude an accidental rodent presence and it supports the hypothesis of Apollo veneration in the temple, based on the already known link between mice and Apollo worship rituals.

  4. circ-SHKBP1 Regulates the Angiogenesis of U87 Glioma-Exposed Endothelial Cells through miR-544a/FOXP1 and miR-379/FOXP2 Pathways

    Directory of Open Access Journals (Sweden)

    Qianru He

    2018-03-01

    Full Text Available Circular RNAs (circRNAs are a type of endogenous non-coding RNAs, which have been considered to mediate diverse tumorigenesis including angiogenesis. The present study aims to elucidate the potential role and molecular mechanism of circ-SHKBP1 in regulating the angiogenesis of U87 glioma-exposed endothelial cells (GECs. The expression of circ-SHKBP1, but not linear SHKBP1, was significantly upregulated in GECs compared with astrocyte-exposed endothelial cells (AECs. circ-SHKBP1 knockdown inhibited the viability, migration, and tube formation of GECs dramatically. The expressions of miR-379/miR-544a were downregulated in GECs, and circ-SHKBP1 functionally targeted miR-544a/miR-379 in an RNA-induced silencing complex (RISC manner. Dual-luciferase reporter assay demonstrated that forkhead box P1/P2 (FOXP1/FOXP2 were targets of miR-544a/miR-379. The expressions of FOXP1/FOXP2 were upregulated in GECs, and silencing of FOXP1/FOXP2 inhibited the viability, migration, and tube formation of GECs. Meanwhile, FOXP1/FOXP2 promoted angiogenic factor with G patch and FHA domains 1 (AGGF1 expression at the transcriptional level. Furthermore, knockdown of AGGF1 suppressed the viability, migration, and tube formation of GECs via phosphatidylinositol 3-kinase (PI3K/AKT and extracellular signal-regulated kinase (ERK1/2 pathways. Taken together, the present study demonstrated that circ-SHKBP1 regulated the angiogenesis of GECs through miR-544a/FOXP1 and miR-379/FOXP2 pathways, and these findings might provide a potential target and effective strategy for combined therapy of gliomas.

  5. A Novel Regulatory Mechanism of Smooth Muscle α-Actin Expression by NRG-1/circACTA2/miR-548f-5p Axis.

    Science.gov (United States)

    Sun, Yan; Yang, Zhan; Zheng, Bin; Zhang, Xin-Hua; Zhang, Man-Li; Zhao, Xue-Shan; Zhao, Hong-Ye; Suzuki, Toru; Wen, Jin-Kun

    2017-09-01

    Neuregulin-1 (NRG-1) includes an extracellular epidermal growth factor-like domain and an intracellular domain (NRG-1-ICD). In response to transforming growth factor-β1, its cleavage by proteolytic enzymes releases a bioactive fragment, which suppresses the vascular smooth muscle cell (VSMC) proliferation by activating ErbB (erythroblastic leukemia viral oncogene homolog) receptor. However, NRG-1-ICD function in VSMCs remains unknown. Here, we characterize the function of NRG-1-ICD and underlying mechanisms in VSMCs. Immunofluorescence staining, Western blotting, and quantitative real-time polymerase chain reaction showed that NRG-1 was expressed in rat, mouse, and human VSMCs and was upregulated and cleaved in response to transforming growth factor-β1. In the cytoplasm of HASMCs (human aortic smooth muscle cells), the NRG-1-ICD participated in filamentous actin formation by interacting with α-SMA (smooth muscle α-actin). In the nucleus, the Nrg-1-ICD induced circular ACTA2 (alpha-actin-2; circACTA2) formation by recruitment of the zinc-finger transcription factor IKZF1 (IKAROS family zinc finger 1) to the first intron of α-SMA gene. We further confirmed that circACTA2, acting as a sponge binding microRNA (miR)-548f-5p, interacted with miR-548f-5p targeting 3' untranslated region of α-SMA mRNA, which in turn relieves miR-548f-5p repression of the α-SMA expression and thus upregulates α-SMA expression, thereby facilitating stress fiber formation and cell contraction in HASMCs. Accordingly, in vivo studies demonstrated that the localization of the interaction of circACTA2 with miR-548f-5p is significantly decreased in human intimal hyperplastic arteries compared with normal arteries, implicating that dysregulation of circACTA2 and miR-548f-5p expression is involved in intimal hyperplasia. These results suggest that circACTA2 mediates NRG-1-ICD regulation of α-SMA expression in HASMCs via the NRG-1-ICD/circACTA2/miR-548f-5p axis. Our data provide a molecular

  6. A review on the CIRCE methodology to quantify the uncertainty of the physical models of a code

    International Nuclear Information System (INIS)

    Jeon, Seong Su; Hong, Soon Joon; Bang, Young Seok

    2012-01-01

    In the field of nuclear engineering, recent regulatory audit calculations of large break loss of coolant accident (LBLOCA) have been performed with the best estimate code such as MARS, RELAP5 and CATHARE. Since the credible regulatory audit calculation is very important in the evaluation of the safety of the nuclear power plant (NPP), there have been many researches to develop rules and methodologies for the use of best estimate codes. One of the major points is to develop the best estimate plus uncertainty (BEPU) method for uncertainty analysis. As a representative BEPU method, NRC proposes the CSAU (Code scaling, applicability and uncertainty) methodology, which clearly identifies the different steps necessary for an uncertainty analysis. The general idea is 1) to determine all the sources of uncertainty in the code, also called basic uncertainties, 2) quantify them and 3) combine them in order to obtain the final uncertainty for the studied application. Using the uncertainty analysis such as CSAU methodology, an uncertainty band for the code response (calculation result), important from the safety point of view is calculated and the safety margin of the NPP is quantified. An example of such a response is the peak cladding temperature (PCT) for a LBLOCA. However, there is a problem in the uncertainty analysis with the best estimate codes. Generally, it is very difficult to determine the uncertainties due to the empiricism of closure laws (also called correlations or constitutive relationships). So far the only proposed approach is based on the expert judgment. For this case, the uncertainty range of important parameters can be wide and inaccurate so that the confidence level of the BEPU calculation results can be decreased. In order to solve this problem, recently CEA (France) proposes a statistical method of data analysis, called CIRCE. The CIRCE method is intended to quantify the uncertainties of the correlations of a code. It may replace the expert judgment

  7. Ulisse all’Isola di Circe (Brussels 1650: Operatic Transformation of Classical Tradition and Dissolution of Stoic Problems

    Directory of Open Access Journals (Sweden)

    Urbański Piotr

    2015-11-01

    Full Text Available The present article is a close reading of the libretto of the first opera (drama musicale staged in the Netherlands, in Brussels in 1650. The main point of interest is Ascanio Amalteo’s transformation or even breakaway from the classical tradition (esp. Homer and Ovid to create a work with its own message, quite distant from classical texts but, paradoxically, approaching moral and psychological categories in Neo-Stoic mode. Perhaps it is not by chance that a parallel piece, Calderon’s second play on Circe (after the fiesta entitled El mayor encanto, amor, 1635, i.e. the auto sacramentale entitled Los encantos de la culpa (ca. 1650, is also a significant transformation of the motive done in the spirit of the Counter-Reformation. Both plays are the last allegorical interpretations of Circe myth and for the next two-hundred years the last important literary works about Ulysses.

  8. RELAP5 and SIMMER-III code assessment on CIRCE decay heat removal experiments

    International Nuclear Information System (INIS)

    Bandini, Giacomino; Polidori, Massimiliano; Meloni, Paride; Tarantino, Mariano; Di Piazza, Ivan

    2015-01-01

    Highlights: • The CIRCE DHR experiments simulate LOHS+LOF transients in LFR systems. • Decay heat removal by natural circulation through immersed heat exchangers is investigated. • The RELAP5 simulation of DHR experiments is presented. • The SIMMER-III simulation of DHR experiments is presented. • The focus is on the transition from forced to natural convection and stratification in a large pool. - Abstract: In the frame of THINS Project of the 7th Framework EU Program on Nuclear Fission Safety, some experiments were carried out on the large scale LBE-cooled CIRCE facility at the ENEA/Brasimone Research Center to investigate relevant safety aspects associated with the removal of decay heat through heat exchangers (HXs) immersed in the primary circuit of a pool-type lead fast reactor (LFR), under loss of heat sink (LOHS) accidental conditions. The start-up and operation of this decay heat removal (DHR) system relies on natural convection on the primary side and then might be affected by coolant mixing and temperature stratification phenomena occurring in the LBE pool. The main objectives of the CIRCE experimental campaign were to verify the behavior of the DHR system under representative accidental conditions and provide a valuable database for the assessment of both CFD and system codes. The reproduced accidental conditions refer to a station blackout scenario, namely a protected LOHS and loss of flow (LOF) transient. In this paper the results of 1D RELAP5 and 2D SIMMER-III simulations are compared with the experimental data of more representative DHR transients T-4 and T-5 in order to verify the capability of these codes to reproduce both forced and natural convection conditions observed in the primary circuit and the right operation of the DHR system for decay heat removal. Both codes are able to reproduce the stationary conditions and with some uncertainties the transition to natural convection conditions until the end of the transient phase. The trend

  9. Hsa-circRNA11783-2 in peripheral blood is correlated with coronary artery disease and type 2 diabetes mellitus.

    Science.gov (United States)

    Li, Xuejie; Zhao, Zhenzhou; Jian, Dongdong; Li, Wentao; Tang, Haiyu; Li, Muwei

    2017-11-01

    The purpose of this study was to identify the expression characteristics of circular RNAs in the peripheral blood of coronary artery disease patients and type 2 diabetes mellitus patients. Circular RNA in the peripheral blood from 6 control individuals, 6 coronary artery disease patients, 6 type 2 diabetes mellitus patients and 6 coronary artery disease combined with type 2 diabetes mellitus patients was collected for microarray analysis, and a further independent cohort consisting of 20 normal individuals, 20 type 2 diabetes mellitus subjects and 20 coronary artery disease subjects was used to verify the expression of five circular RNAs chosen for further analysis. The findings were then tested in a third cohort using quantitative real-time polymerase chain reaction. In total, 40 circular RNAs differentially expressed between the three experimental groups and the control group were identified by microarray analysis: 13 were upregulated in the experimental groups, while 27 were downregulated. Of the five circular RNAs chosen for further analysis, three were significantly downregulated in the experimental groups. The crude odds ratios and adjusted odds ratios of hsa-circRNA11783-2 showed significant differences in both the coronary artery disease group and type 2 diabetes mellitus group. We then verified hsa-circRNA11783-2 in the third cohort, and it remained closely related to both coronary artery disease and type 2 diabetes mellitus. Hsa-circRNA11783-2 is closely related to both coronary artery disease and type 2 diabetes mellitus.

  10. Circe and other mythological allusions in the story and film of Cortázar

    Directory of Open Access Journals (Sweden)

    Hugo Salcedo Larios

    2018-01-01

    Full Text Available The neat work of Julio Cortázar also included little known exercise dramatic theirs which constitutes a repertoire of several plays of his own, as well as some stories of best broadcasting, and whose thematic axis is fed myths Greek or Mesoamerican, some of which turned into screenplays. The purpose of this work is to mark a reference line in tone to the story his "Circe" from his book Bestiario, and in which the author worked as screenwriter.

  11. Mass and abundance 236U sensitivities at CIRCE

    Science.gov (United States)

    De Cesare, M.; De Cesare, N.; D'Onofrio, A.; Fifield, L. K.; Gialanella, L.; Terrasi, F.

    2015-10-01

    The actinides (e.g. 236U and xPu isotopes) are present in environmental samples at the ultra trace level since atmospheric tests of NWs (Nuclear Weapons) performed in the past, deliberate dumping of nuclear waste, nuclear fuel reprocessing, on a large scale and operation of NPPs (Nuclear Power Plants) on a small scale have led to the release of a wide range of radioactive nuclides in the environment. Their detection requires the most sensitive AMS (Accelerator Mass Spectrometry) techniques and at the Center for Isotopic Research on Cultural and Environmental heritage (CIRCE) in Caserta, Italy, an upgraded actinide AMS system, based on a 3-MV pelletron tandem accelerator, has been operated. In this paper the progress made in order to push the 236U mass sensitivity and 236U/238U isotopic ratio down to the natural levels is reported. A uranium contamination mass of about 0.05 μg and a 236U/238U isotopic ratio sensitivities at the level of 3.2 × 10-13 are presently achievable.

  12. Metastable State Diamond Growth and its Applications to Electronic Devices.

    Science.gov (United States)

    Jeng, David Guang-Kai

    Diamond which consists of a dense array of carbon atoms joined by strong covalent bonds and formed into a tetrahedral crystal structure has remarkable mechanical, thermal, optical and electrical properties suitable for many industrial applications. With a proper type of doping, diamond is also an ideal semiconductor for high performance electronic devices. Unfortunately, natural diamond is rare and limited by its size and cost, it is not surprising that people continuously look for a synthetic replacement. It was believed for long time that graphite, another form of carbon, may be converted into diamond under high pressure and temperature. However, the exact condition of conversion was not clear. In 1939, O. I. Leipunsky developed an equilibrium phase diagram between graphite and diamond based on thermodynamic considerations. In the phase diagram, there is a low temperature (below 1000^ circC) and low pressure (below 1 atm) region in which diamond is metastable and graphite is stable, therefore establishes the conditions for the coexistence of the two species. Leipunsky's pioneer work opened the door for diamond synthesis. In 1955, the General Electric company (GE) was able to produce artificial diamond at 55k atm pressure and a temperature of 2000^ circC. Contrary to GE, B. Derjaguin and B. V. Spitzyn in Soviet Union, developed a method of growing diamonds at 1000^circC and at a much lower pressure in 1956. Since then, researchers, particularly in Soviet Union, are continuously looking for methods to grow diamond and diamond film at lower temperatures and pressures with slow but steady progress. It was only in the early 80's that the importance of growing diamond films had attracted the attentions of researchers in the Western world and in Japan. Recent progress in plasma physics and chemical vapor deposition techniques in integrated electronics technology have pushed the diamond growth in its metastable states into a new era. In this research, a microwave plasma

  13. Mass and abundance {sup 236}U sensitivities at CIRCE

    Energy Technology Data Exchange (ETDEWEB)

    De Cesare, M., E-mail: m.decesare@cira.it [Department of Nuclear Physics, Research School of Physics and Engineering, Australian National University, ACT 0200 Canberra (Australia); CIRCE and Dipartimento di Matematica e Fisica, Seconda Universitá di Napoli, via Vivaldi 43, 81100 Caserta (Italy); De Cesare, N.; D’Onofrio, A. [CIRCE and Dipartimento di Matematica e Fisica, Seconda Universitá di Napoli, via Vivaldi 43, 81100 Caserta (Italy); INFN Sezione di Napoli, via Cintia, Edificio G, 80126 Napoli (Italy); Fifield, L.K. [Department of Nuclear Physics, Research School of Physics and Engineering, Australian National University, ACT 0200 Canberra (Australia); Gialanella, L.; Terrasi, F. [CIRCE and Dipartimento di Matematica e Fisica, Seconda Universitá di Napoli, via Vivaldi 43, 81100 Caserta (Italy); INFN Sezione di Napoli, via Cintia, Edificio G, 80126 Napoli (Italy)

    2015-10-15

    The actinides (e.g. {sup 236}U and {sup x}Pu isotopes) are present in environmental samples at the ultra trace level since atmospheric tests of NWs (Nuclear Weapons) performed in the past, deliberate dumping of nuclear waste, nuclear fuel reprocessing, on a large scale and operation of NPPs (Nuclear Power Plants) on a small scale have led to the release of a wide range of radioactive nuclides in the environment. Their detection requires the most sensitive AMS (Accelerator Mass Spectrometry) techniques and at the Center for Isotopic Research on Cultural and Environmental heritage (CIRCE) in Caserta, Italy, an upgraded actinide AMS system, based on a 3-MV pelletron tandem accelerator, has been operated. In this paper the progress made in order to push the {sup 236}U mass sensitivity and {sup 236}U/{sup 238}U isotopic ratio down to the natural levels is reported. A uranium contamination mass of about 0.05 μg and a {sup 236}U/{sup 238}U isotopic ratio sensitivities at the level of 3.2 × 10{sup −13} are presently achievable.

  14. Investigating the Effects of Group Investigation (GI and Cooperative Integrated Reading and Comprehension (CIRC as the Cooperative Learning Techniques on Learner's Reading Comprehension

    Directory of Open Access Journals (Sweden)

    Mohammad Amin Karafkan

    2015-11-01

    Full Text Available Cooperative learning consists of some techniques for helping students work together more effectively. This study investigated the effects of Group Investigation (GI and Cooperative Integrated Reading and Composition (CIRC as cooperative learning techniques on Iranian EFL learners’ reading comprehension at an intermediate level. The participants of the study were 207 male students who studied at an intermediate level at ILI. The participants were randomly assigned into three equal groups: one control group and two experimental groups. The control group was instructed via conventional technique following an individualistic instructional approach. One experimental group received GI technique. The other experimental group received CIRC technique. The findings showed that there was a meaningful difference between the mean of the reading comprehension score of GI experimental group and CRIC experimental group. CRIC technique is more effective than GI technique in enhancing the reading comprehension test scores of students.

  15. Pre-test analysis of protected loss of primary pump transients in CIRCE-HERO facility

    Science.gov (United States)

    Narcisi, V.; Giannetti, F.; Del Nevo, A.; Tarantino, M.; Caruso, G.

    2017-11-01

    In the frame of LEADER project (Lead-cooled European Advanced Demonstration Reactor), a new configuration of the steam generator for ALFRED (Advanced Lead Fast Reactor European Demonstrator) was proposed. The new concept is a super-heated steam generator, double wall bayonet tube type with leakage monitoring [1]. In order to support the new steam generator concept, in the framework of Horizon 2020 SESAME project (thermal hydraulics Simulations and Experiments for the Safety Assessment of MEtal cooled reactors), the ENEA CIRCE pool facility will be refurbished to host the HERO (Heavy liquid mEtal pRessurized water cOoled tubes) test section to investigate a bundle of seven full scale bayonet tubes in ALFRED-like thermal hydraulics conditions. The aim of this work is to verify thermo-fluid dynamic performance of HERO during the transition from nominal to natural circulation condition. The simulations have been performed with RELAP5-3D© by using the validated geometrical model of the previous CIRCE-ICE test section [2], in which the preceding heat exchanger has been replaced by the new bayonet bundle model. Several calculations have been carried out to identify thermal hydraulics performance in different steady state conditions. The previous calculations represent the starting points of transient tests aimed at investigating the operation in natural circulation. The transient tests consist of the protected loss of primary pump, obtained by reducing feed-water mass flow to simulate the activation of DHR (Decay Heat Removal) system, and of the loss of DHR function in hot conditions, where feed-water mass flow rate is absent. According to simulations, in nominal conditions, HERO bayonet bundle offers excellent thermal hydraulic behavior and, moreover, it allows the operation in natural circulation.

  16. The Effect of Two Methods of Pomegranate (Punica granatum L) Juice Extraction on Quality During Storage at $4^\\circ$ C.

    Science.gov (United States)

    Miguel, Graça; Dandlen, Susana; Antunes, Dulce; Neves, Alcinda; Martins, Denise

    2004-01-01

    The effect of two extraction methods of pomegranate juice on its quality and stability was evaluated. The first method consisted of separation of the seeds from fruits and centrifugation. The second method consisted of squeezing fruit halves with an electric lemon squeezer. During a period of 72 hours of cold storage at $4^\\circ$ C, the juices were evaluated for the presence of sugars, organic acids, and anthocyanins. Delphinidin 3-glucoside was identified to be the major anthocyanin present at the level of 45-69 mg/L. Among the organic acids, oxalic and tartaric acids dominated. The major sugars detected in pomegranate juice were glucose and sucrose. No significant differences in the content of sugars, organic acids, or anthocyanins in juices obtained through application of the two different extraction methods were detected, with the exception of the drastic decrease of cyanidin $3,5$ -diglucoside level in juice obtained by seed centrifugation. The pH did not show differences between treatments. Titrable acidity and the level of sugars expressed as ${}^{\\circ}$ Brix decreased after 32 and 15 hours after extraction, respectively, when juice was obtained by centrifuging the seeds.

  17. Testing and qualification of CIRCE venturi-nozzle flow meter for large scale experiments

    International Nuclear Information System (INIS)

    Ambrosini, W.; Forgione, N.; Oriolo, F.; Tarantino, M.; Agostini, P.; Benamati, G.; Bertacci, G.; Elmi, N.; Alemberti, A.; Cinotti, L.; Scaddozzo, G.

    2005-01-01

    This paper is focused on the tests carried out at the ENEA Brasimone Centre for the qualification of a large Venturi-Nozzle flow meter operating in Lead Bismuth Eutectic (LBE). Such flow meter has been selected to provide flow rate measurements during the thermal-hydraulic tests that will be performed on the experimental facility CIRCE. This large-scale facility is installed at the ENEA Brasimone Centre for studying the fluid-dynamics and operating behaviour of ADS reactor plants, as well as to qualify several components intended to be used in the LBE technology. The Venturi-Nozzle flow meter has been supplied by the Euromisure s.r.l., together with the calculated theoretical characteristic equation. The results obtained by the tests performed allowed to qualify this theoretical curve supplied by the manufacturer, that presents a very good agreement especially at high flow rate values. (authors)

  18. Radiological Safety Aspects of the operation of the Electron Linear Accelerator Linac CIRCE III 10 MeV

    International Nuclear Information System (INIS)

    Naceur, Ahmed

    2014-01-01

    This document is a report about safety and security for the electron accelerator Linac-CIRCE III of the National Center for Nuclear Sciences and Technologies of Tunis. The paper aims to introduce the standards of the International Atomic Energy Agency (IAEA) to the installation in question. Overall, it draws its profit from the official security reports of the IAEA. First, we study the anatomy of the accelerator by breaking it down into various compartments and examining the case of leaks that may arise. This part introduces the particularity of this installation and allows us to meet and provide procedures for some typical scenarios of mechanical malfunction. Second, we recall and adapt some theoretical concepts related to the quantification of the radioactivity, the thickness of the armoring, the utilization factor, and the quality factor. Thus, we become able to list of types of these radiations, dangers, risks and their sources. We also examine the phenomenon of compartments activation, toxic gases production (including ozone), the process of elimination, the danger associated with X-rays generated by high voltage system and the risk of electrocution. In light of this study, we handle mathematically the question of the armoring and the concept of radiation protection. Therefore, we present a practical methodology to implement a monitoring system and a technicality in the interpretation of the measurements. Finally, we discuss the practical aspect by introducing security governance to CIRCE III, and establishing a program of general, radiological and specific security. Then, we evaluate the areas of typical security, and present a comparative radiological study between the results obtained by the IAEA standards and those by the German DIN 6847 standard for direct Bremsstrahlung radiation and scattered radiation.

  19. Ultra-High Precision Half-Life Measurement for the Superallowed &+circ; Emitter ^26Al^m

    Science.gov (United States)

    Finlay, P.; Demand, G.; Garrett, P. E.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Svensson, C. E.; Triambak, S.; Grinyer, G. F.; Leslie, J. R.; Andreoiu, C.; Cross, D.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Djongolov, M.; Ettenauer, S.; Hackman, G.; Pearson, C. J.; Williams, S. J.

    2009-10-01

    The calculated nuclear structure dependent correction for ^26Al^m (δC-δNS= 0.305(27)% [1]) is smaller by nearly a factor of two than the other twelve precision superallowed cases, making it an ideal case to pursue a reduction in the experimental errors contributing to the Ft value. An ultra-high precision half-life measurement for the superallowed &+circ; emitter ^26Al^m has been made at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF in Vancouver, Canada. A beam of ˜10^5 ^26Al^m/s was delivered in October 2007 and its decay was observed using a 4π continuous gas flow proportional counter as part of an ongoing experimental program in superallowed Fermi β decay studies. With a statistical precision of ˜0.008%, the present work represents the single most precise measurement of any superallowed half-life to date. [4pt] [1] I.S. Towner and J.C. Hardy, Phys. Rev. C 79, 055502 (2009).

  20. Bioartificial liver assist devices in support of patients with liver failure.

    Science.gov (United States)

    Patzer II, John F; Lopez, Roberto C; Zhu, Yue; Wang, Zi-Fa; Mazariegos, George V; Fung, John J

    2002-02-01

    Bioartificial liver assist devices (BALs) offer an opportunity for critical care physicians and transplant surgeons to stabilize patients prior to orthotopic liver transplantation. Such devices may also act as a bridge to transplant, providing liver support to patients awaiting transplant, or as support for patients post living-related donor transplant. Four BAL devices that rely on hepatocytes cultured in hollow fiber membrane cartridges (Circe Biomedical HepatAssist(r), Vitagen ELADTM, Gerlach BELS, and Excorp Medical BLSS) are currently in various stages of clinical evaluation. Comparison of the four devices shows that several unique approaches based upon the same overall system architecture are possible. Preliminary results of the Excorp Medical BLSS Phase I safety evaluation at the University of Pittsburgh, after treating four patients (F, 41, acetominophen-induced, two support periods; M, 50, Wilson's disease, one support period; F, 53, acute alcoholic hepatitis, two support periods; F, 24, chemotherapy-induced, one support period, are presented. All patients presented with hypoglycemia and transient hypotension at the start of extracorporeal perfusion. Hypoglycemia was treated by IV dextrose and the transient hypotension responded positively to IV fluid bolus. Heparin anticoagulation was used only in the second patient. No serious or adverse events were noted in the four patients. Moderate Biochemical response to support was noted in all patients. More complete characterization of the safety of the BLSS requires completion of the Phase I safety evaluation.

  1. Forensic applications of {sup 14}C at CIRCE

    Energy Technology Data Exchange (ETDEWEB)

    Marzaioli, F., E-mail: fabio.marzaioli@unina2.it [CIRCE, Dipartimento di Scienze Ambientali, Seconda Universita degli Studi di Napoli and INNOVA, Via Vivaldi 43, 81100 Caserta (Italy); Fiumano, V., E-mail: vittoriofiumano85@libero.it [CIRCE, Dipartimento di Scienze della Vita, Seconda Universita degli Studi di Napoli and INNOVA, Via Vivaldi 43, 81100 Caserta (Italy); Capano, M., E-mail: manuela.capano@unina2.it [CIRCE, Dipartimento di Studio delle Componenti Culturali del Territorio, Seconda Universita degli Studi di Napoli and INNOVA, Piazza S. Francesco, 81055 Santa Maria Capua Vetere, Caserta (Italy); Passariello, I., E-mail: isabella.passariello@unina2.it [CIRCE, Dipartimento di Scienze Ambientali, Seconda Universita degli Studi di Napoli and INNOVA, Via Vivaldi 43, 81100 Caserta (Italy); Cesare, N.De., E-mail: nicola.decesare@unina2.it [CIRCE, Dipartimento di Scienze della Vita, Seconda Universita degli Studi di Napoli and INNOVA, Via Vivaldi 43, 81100 Caserta (Italy); Terrasi, F., E-mail: filippo.terrasi@unina2.it [CIRCE, Dipartimento di Scienze Ambientali, Seconda Universita degli Studi di Napoli and INNOVA, Via Vivaldi 43, 81100 Caserta (Italy)

    2011-12-15

    The decreasing trend of the radiocarbon pulse produced during the atmospheric tests of nuclear weapons (bomb-carbon) coupled with high sensitivity accelerator mass spectrometry (AMS) measurements, drastically increased the precision of radiocarbon age determinations since the second part of the sixties, allowing the application of radiocarbon AMS to a wide range of studies previously not directly involving conventional radiocarbon dating (i.e. food authenticity, forensic, biochemistry). In the framework of authenticity evaluation of artworks, high precision radiocarbon ({sup 14}C) AMS measurements ({Delta}R/R < 0.3%) reduce the conventional uncertainty of the dating to few decades, allowing precise age estimation of materials containing carbon (C). The Centre for Isotopic Research on Cultural and Environmental heritage (CIRCE) during its activity on AMS {sup 14}C dating achieved high precision measurements opening the opportunity to these kinds of applications. This paper presents the main results obtained from radiocarbon measurements on a set of bone samples analyzed for the determination of the post-mortem interval in the framework of an unsolved case investigated by the Rome prosecutor office. The chronological characterization of the wooden support of the 'Acerenza portrait' is also presented with the aim to evaluate its age and to further investigate the possibility to attribute this artwork to Leonardo da Vinci. Bomb-{sup 14}C dating on the lipid and collagen fractions of bones allows the evaluation of the year of the death of the individuals by means of ad hoc calibration data sheet with the typical few years precision and difference between collagen apparent age and the year of death appeared in agreement with the age of one individual estimated by dating of tooth collagen. Conventional radiocarbon dating on both wood and wood extracted cellulose leads to an estimation of the portrait wood board age (2{sigma}) of 1459-1524 AD (57% relative

  2. Neutronic evolution of SENA reactor during the first and second cycles. Comparison between the experimental power distributions obtained from the in-core instrumentation evaluation code CIRCE and the theoretical power values computed with the two-dimensional diffusion-evolution code EVOE

    International Nuclear Information System (INIS)

    Andrieux, Chantal

    1976-03-01

    The neutronic evolution of the reacteur Sena during the first and second cycles is presented. The experimental power distributions, obtained from the in-core instrumentation evaluation code CIRCE are compared with the theoretical powers calculated with the two-dimensional diffusion-evolution code EVOE. The CIRCE code allows: the study of the evolution of the principal parameters of the core, the comparison of the results of measured and theoretical estimates. Therefore this study has a great interest for the knowledge of the neutronic evolution of the core, as well as the validation of the refinement of theoretical estimation methods. The core calculation methods and requisite data for the evaluation of the measurements are presented after a brief description of the SENA core and its inner instrumentation. The principle of the in-core instrumentation evaluation code CIRCE, and calculation of the experimental power distributions and nuclear core parameters are then exposed. The results of the evaluation are discussed, with a comparison of the theoretical and experimental results. Taking account of the approximations used, these results, as far as the first and second cycles at SENA are concerned, are satisfactory, the deviations between theoretical and experimental power distributions being lower than 3% at the middle of the reactor and 9% at the periphery [fr

  3. Estudio del efecto de la adición de distintos mineralizadores en la síntesis cerámica del pigmento rosa coral de hierro-circón

    Directory of Open Access Journals (Sweden)

    Llusar, M.

    1999-06-01

    Full Text Available The addition of several mineralizing agents (alkaline or alkaline-earth halides, KNO3, etc. in the traditional ceramic synthesis of the “coral pink” iron-zircon (Fe-ZrSiO4 ceramic pigment has been analysed, using two different Fe precursors (sulphate and goethite. FeSO4.7H2O employment as Fe precursor allows us to obtain a better reddish colour than with goethite (FeO(OH. Results let us to classify the studied mineralisers in two major groups: i primary or zircon-forming mineralisers, which activate somehow zircon formation with a good occlusion efficiency of hematite into the zircon matrix (NaF, NaCl and BaF2 when using FeSO4 and Na2SiF6 and NaAl3F6 with goethite,. and ii secondary or modifying mineralisers, that have a collateral effect on the pigment synthesis regulating both hematite crystallisation and occlusion (KNO3, Na2SiF6 and NaAl3F6 with FeSO4 and KI and KNO3 with goethite. With regard to the color yield, those compositions mineralised with the binary systems NaF-Na2SiF6, NaF-NaAl3F6 and NaF-KNO3 have been found to develop the best red color.

    Se ha analizado el efecto de la adición de distintos agentes mineralizadores (haluros alcalinos y alcalino-térreos, KNO3, etc. en la síntesis cerámica tradicional del pigmento rosa coral de hierro-circón (Fe-ZrSiO4, usando dos precursores diferentes para el hierro (sulfato y goetita. El empleo de FeSO4.7H2O como fuente de hierro permite obtener mejores coloraciones rojizas que con goetita (FeO(OH. Los resultados obtenidos permiten clasificar a los distintos mineralizadores ensayados en dos grandes grupos: i mineralizadores primarios o “formadores de circón”, los cuales permiten activar el desarrollo del circón con una buena eficiencia en el encapsulamiento de la hematita en los cristales de circón (NaF, NaCl y BaF2 con FeSO4, y Na2SiF6 y NaAl3F6 con goetita, y ii mineralizadores “secundarios o coadyuvantes”, con un efecto colateral sobre la síntesis del pigmento

  4. Experimental study on gas-injection enhanced circulation performed with the CIRCE facility

    International Nuclear Information System (INIS)

    Benamati, G.; Foletti, C.; Forgione, N.; Oriolo, F.; Scaddozzo, G.; Tarantino, M.

    2007-01-01

    This paper describes the results of an experimental campaign concerning the possibility of achieving a steady state circulation by gas-injection in a pool containing lead-bismuth eutectic (LBE) as working fluid. The activity was aimed at gaining information about the basic mechanisms of the gas injection enhanced circulation intended as a pumping system for a liquid metal cooled reactor. In particular, the paper is focused on the experimental work performed in the CIRCE large-scale facility, installed at the ENEA Brasimone Centre for studying the fluid-dynamic and operating behaviour of ADS reactor plants cooled by LBE. The gas enhanced circulation tests were carried out for different LBE temperatures (from 200 to 320 deg. C), under isothermal conditions and with a wide range of argon injected flow rates (from 0.5 to 7.0 Nl/s). The gas is injected from the bottom of the riser, by means of an appropriate nozzle, and the liquid metal flow rate is measured by a Venturi-Nozzle flow meter installed in the single phase part of the test section. The obtained results allowed formulating a characteristic curve of the system and evaluating the void fraction distribution along the riser path by means differential pressure measurements, which play an important role to generating the driving force for the circulation

  5. Study of 236U/238U ratio at CIRCE using a 16-strip silicon detector with a TOF system

    Science.gov (United States)

    De Cesare, M.; De Cesare, N.; D'Onofrio, A.; Gialanella, L.; Terrasi, F.

    2015-04-01

    Accelerator Mass Spectrometry (AMS) is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and xPu isotopes. A new actinide AMS system, based on a 3-MV pelletron tandem accelerator, is operated at the Center for Isotopic Research on Cultural and Environmental Heritage (CIRCE) in Caserta, Italy. In this paper we report on the procedure adopted to increase the 236U abundance sensitivity as low as possible. The energy and position determinations of the 236U ions, using a 16-strip silicon detector have been obtained. A 236U/238U isotopic ratio background level of about 2.9×10-11 was obtained, summing over all the strips, using a Time of Flight-Energy (TOF-E) system with a 16-strip silicon detector (4.9×10-12 just with one strip).

  6. Study of 236U/238U ratio at CIRCE using a 16-strip silicon detector with a TOF system

    Directory of Open Access Journals (Sweden)

    De Cesare M.

    2015-01-01

    Full Text Available Accelerator Mass Spectrometry (AMS is presently the most sensitive technique for the measurement of long-lived actinides, e.g. 236U and xPu isotopes. A new actinide AMS system, based on a 3-MV pelletron tandem accelerator, is operated at the Center for Isotopic Research on Cultural and Environmental Heritage (CIRCE in Caserta, Italy. In this paper we report on the procedure adopted to increase the 236U abundance sensitivity as low as possible. The energy and position determinations of the 236U ions, using a 16-strip silicon detector have been obtained. A 236U/238U isotopic ratio background level of about 2.9×10−11 was obtained, summing over all the strips, using a Time of Flight-Energy (TOF-E system with a 16-strip silicon detector (4.9×10−12 just with one strip.

  7. Extension of the Child-Langmuir law to a beam of particles having an initial velocity; Extension de la loi de Child-Langmuir a un faisceau de particules anime d'une vitesse dirigee

    Energy Technology Data Exchange (ETDEWEB)

    Geller, R [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    A DC ion current of 50 mA/cm{sup 2} has been obtained with approximately 100 volts extraction from the plasma created by the CIRCE device, and a still stronger electron current was obtained with a still lower extraction. These results are an order of magnitude higher than the ordinary characteristics. In the neutral plasma beam produced in the CIRCE device, the ions have mainly longitudinal energy whereas the electron energy is transverse. This situation makes the charge separation easier. In the present paper one tries to explain partially the result on a basis of current increase due to the initial velocity of the particles. (author) [French] On a verifie qu'il etait possible d'extraire, en regime continu, du plasma fourni par la machine CIRCE des courants de protons d'environ 50 mA/cm{sup 2} avec des tensions d'extraction d'environ 100 volts et des courants d'electrons d'une intensite encore plus forte avec quelques volts d'extraction. Ces resultats sont d'un ordre de grandeur superieur aux performances des sources classiques. Dans le faisceau neutre produit par CIRCE les ions sont doues d'une energie essentiellement longitudinale alors que l'energie des electrons est surtout transverse. Cette situation est favorable a une separation. Dans le present rapport nous essayons de donner une explication du mecanisme physique d'une partie du phenomene: celle concernant l'accroissement du courant de protons, du a leur vitesse dirigee. (auteur)

  8. Influence of the nozzle angle on refrigeration performance of a gas wave refrigerator

    Science.gov (United States)

    Liu, P.; Zhu, Y.; Wang, H.; Zhu, C.; Zou, J.; Wu, J.; Hu, D.

    2017-05-01

    A gas wave refrigerator (GWR) is a novel refrigerating device that refrigerates a medium by shock waves and expansion waves generated by gas pressure energy. In a typical GWR, the injection energy losses between the nozzle and the expansion tube are essential factors which influence the refrigeration efficiency. In this study, numerical simulations are used to analyze the underlying mechanism of the injection energy losses. The results of simulations show that the vortex loss, mixing energy loss, and oblique shock wave reflection loss are the main factors contributing to the injection energy losses in the expansion tube. Furthermore, the jet angle of the gas is found to dominate the injection energy losses. Therefore, the optimum jet angle is theoretically calculated based on the velocity triangle method. The value of the optimum jet angle is found to be 4^{circ }, 8^{circ }, and 12^{circ } when the refrigeration efficiency is the first-order, second-order, and third-order maximum value over all working ranges of jet frequency, respectively. Finally, a series of experiments are conducted with the jet angle ranging from -4^{circ } to 12^{circ } at a constant expansion ratio. The results indicate the optimal jet angle obtained by the experiments is in good agreement with the calculated value. The isentropic refrigeration efficiency increased by about 4 % after the jet angle was optimized.

  9. CIRCE2/DEKGEN2: A software package for facilitated optical analysis of 3-D distributed solar energy concentrators. Theory and user manual

    Energy Technology Data Exchange (ETDEWEB)

    Romero, V.J.

    1994-03-01

    CIRCE2 is a computer code for modeling the optical performance of three-dimensional dish-type solar energy concentrators. Statistical methods are used to evaluate the directional distribution of reflected rays from any given point on the concentrator. Given concentrator and receiver geometries, sunshape (angular distribution of incident rays from the sun), and concentrator imperfections such as surface roughness and random deviation in slope, the code predicts the flux distribution and total power incident upon the target. Great freedom exists in the variety of concentrator and receiver configurations that can be modeled. Additionally, provisions for shading and receiver aperturing are included.- DEKGEN2 is a preprocessor designed to facilitate input of geometry, error distributions, and sun models. This manual describes the optical model, user inputs, code outputs, and operation of the software package. A user tutorial is included in which several collectors are built and analyzed in step-by-step examples.

  10. HLM fuel pin bundle experiments in the CIRCE pool facility

    Energy Technology Data Exchange (ETDEWEB)

    Martelli, Daniele, E-mail: daniele.martelli@ing.unipi.it [University of Pisa, Department of Civil and Industrial Engineering, Pisa (Italy); Forgione, Nicola [University of Pisa, Department of Civil and Industrial Engineering, Pisa (Italy); Di Piazza, Ivan; Tarantino, Mariano [Italian National Agency for New Technologies, Energy and Sustainable Economic Development, C.R. ENEA Brasimone (Italy)

    2015-10-15

    Highlights: • The experimental results represent the first set of values for LBE pool facility. • Heat transfer is investigated for a 37-pin electrical bundle cooled by LBE. • Experimental data are presented together with a detailed error analysis. • Nu is computed as a function of the Pe and compared with correlations. • Experimental Nu is about 25% lower than Nu derived from correlations. - Abstract: Since Lead-cooled Fast Reactors (LFR) have been conceptualized in the frame of GEN IV International Forum (GIF), great interest has focused on the development and testing of new technologies related to HLM nuclear reactors. In this frame the Integral Circulation Experiment (ICE) test section has been installed into the CIRCE pool facility and suitable experiments have been carried out aiming to fully investigate the heat transfer phenomena in grid spaced fuel pin bundles providing experimental data in support of European fast reactor development. In particular, the fuel pin bundle simulator (FPS) cooled by lead bismuth eutectic (LBE), has been conceived with a thermal power of about 1 MW and a uniform linear power up to 25 kW/m, relevant values for a LFR. It consists of 37 fuel pins (electrically simulated) placed on a hexagonal lattice with a pitch to diameter ratio of 1.8. The FPS was deeply instrumented by several thermocouples. In particular, two sections of the FPS were instrumented in order to evaluate the heat transfer coefficient along the bundle as well as the cladding temperature in different ranks of sub-channels. Nusselt number in the central sub-channel was therefore calculated as a function of the Peclet number and the obtained results were compared to Nusselt numbers obtained from convective heat transfer correlations available in literature on Heavy Liquid Metals (HLM). Results reported in the present work, represent the first set of experimental data concerning fuel pin bundle behaviour in a heavy liquid metal pool, both in forced and

  11. Troubadour Biographies and the Value of Authentic Love: Daude de Pradas and Uc de Saint Circ

    Directory of Open Access Journals (Sweden)

    Thomas Hinton

    2017-05-01

    Full Text Available The idea of an essential connection between the quality of a song and the sincerity of the emotion it expresses ("I sing because I love" is a topos used in various ways by troubadours, one which lent itself naturally to discussion of their relationship to audiences and to other poets. The topos transferred across to the thirteenth-century biographies (vidas found alongside the songs in numerous manuscripts, as in the arresting claim, made in the vida about Daude de Pradas, that his songs "did not spring from love and therefore did not find favour with audiences." Elsewhere, however, the biographies give a different account of inauthenticity, as the edge which allows troubadours to exercise control over their social environment; significantly, this version of the topos appears in the vida for Uc de Saint Circ, who is believed to be the main author of the corpus. In these contrasting accounts of poetic inauthenticity, we can see the biographies wrestling with questions of control and definition of the cultural capital of troubadour lyric: patron and poet, cleric and lay. The thirteenth century saw authors and their audiences increasingly asserting the lasting cultural value of vernacular literature in general, and (through its association with troubadour production Occitan in particular. Accordingly, these texts reflect the poets' engagement with the court audiences for whom they were writing, at the same time as they look ahead to the enduring record of posterity.

  12. Circular RNAs and systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Li, Lian-Ju; Huang, Qing; Pan, Hai-Feng; Ye, Dong-Qing, E-mail: ydqahmu@gmail.com

    2016-08-15

    Circular RNAs (circRNAs) are a large class of noncoding RNAs that form covalently closed RNA circles. The discovery of circRNAs discloses a new layer of gene regulation occurred post-transcriptionally. Identification of endogenous circRNAs benefits from the advance in high-throughput RNA sequencing and remains challenging. Many studies probing into the mechanisms of circRNAs formation occurred cotranscriptionally or posttranscriptionally emerge and conclude that canonical splicing mechanism, sequence properties, and certain regulatory factors are at play in the process. Although our knowledge on functions of circRNAs is rather limited, a few circRNAs are shown to sponge miRNA and regulate gene transcription. The clearest case is one circRNA CDR1as that serves as sponge of miR-7. Researches on circRNAs in human diseases such as cancers highlight the function and physical relevance of circRNAs. Given the implication of miRNAs in the initiation and progression of systemic lupus erythematosus (SLE) and the roles of circRNAs in sponging miRNA and gene regulation, it is appealing to speculate that circRNAs may associate with SLE and may be potential therapeutic targets for treatment of SLE. Future studies should attach more importance to the relationship between circRNAs and SLE. This review will concern identification, biogenesis, and function of circRNAs, introduce reports exploring the association of circRNAs with human diseases, and conjecture the potential roles of circRNAs in SLE. - Highlights: • Studies have discovered thousands of circRNAs and interpreted their biogenesis. • Cytoplasmic circRNAs sponge miRNA and nuclear circRNAs modulate gene transcription. • Aberrant expression of circRNAs has been observed in various cancers. • CircRNAs may partake in the pathogenesis of systemic lupus erythematosus.

  13. Circular RNAs and systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Li, Lian-Ju; Huang, Qing; Pan, Hai-Feng; Ye, Dong-Qing

    2016-01-01

    Circular RNAs (circRNAs) are a large class of noncoding RNAs that form covalently closed RNA circles. The discovery of circRNAs discloses a new layer of gene regulation occurred post-transcriptionally. Identification of endogenous circRNAs benefits from the advance in high-throughput RNA sequencing and remains challenging. Many studies probing into the mechanisms of circRNAs formation occurred cotranscriptionally or posttranscriptionally emerge and conclude that canonical splicing mechanism, sequence properties, and certain regulatory factors are at play in the process. Although our knowledge on functions of circRNAs is rather limited, a few circRNAs are shown to sponge miRNA and regulate gene transcription. The clearest case is one circRNA CDR1as that serves as sponge of miR-7. Researches on circRNAs in human diseases such as cancers highlight the function and physical relevance of circRNAs. Given the implication of miRNAs in the initiation and progression of systemic lupus erythematosus (SLE) and the roles of circRNAs in sponging miRNA and gene regulation, it is appealing to speculate that circRNAs may associate with SLE and may be potential therapeutic targets for treatment of SLE. Future studies should attach more importance to the relationship between circRNAs and SLE. This review will concern identification, biogenesis, and function of circRNAs, introduce reports exploring the association of circRNAs with human diseases, and conjecture the potential roles of circRNAs in SLE. - Highlights: • Studies have discovered thousands of circRNAs and interpreted their biogenesis. • Cytoplasmic circRNAs sponge miRNA and nuclear circRNAs modulate gene transcription. • Aberrant expression of circRNAs has been observed in various cancers. • CircRNAs may partake in the pathogenesis of systemic lupus erythematosus.

  14. High-Throughput Data of Circular RNA Profiles in Human Temporal Cortex Tissue Reveals Novel Insights into Temporal Lobe Epilepsy.

    Science.gov (United States)

    Li, Jiaxin; Lin, Haijun; Sun, Zhenrong; Kong, Guanyi; Yan, Xu; Wang, Yujiao; Wang, Xiaoxuan; Wen, Yanhua; Liu, Xiang; Zheng, Hongkun; Jia, Mei; Shi, Zhongfang; Xu, Rong; Yang, Shaohua; Yuan, Fang

    2018-01-01

    Circular RNAs (circRNAs) are a class of long noncoding RNAs with a closed loop structure that regulate gene expression as microRNA sponges. CircRNAs are more enriched in brain tissue, but knowledge of the role of circRNAs in temporal lobe epilepsy (TLE) has remained limited. This study is the first to identify the global expression profiles and characteristics of circRNAs in human temporal cortex tissue from TLE patients. Temporal cortices were collected from 17 TLE patients and 17 non-TLE patients. Total RNA was isolated, and high-throughput sequencing was used to profile the transcriptome of dysregulated circRNAs. Quantitative PCR was performed for the validation of changed circRNAs. In total, 78983 circRNAs, including 15.29% known and 84.71% novel circRNAs, were detected in this study. Intriguingly, 442 circRNAs were differentially expressed between the TLE and non-TLE groups (fold change≥2.0 and FDR≤0.05). Of these circRNAs, 188 were up-regulated, and 254 were down-regulated in the TLE patient group. Eight circRNAs were validated by real-time PCR. Remarkably, circ-EFCAB2 was intensely up-regulated, while circ-DROSHA expression was significantly lower in the TLE group than in the non-TLE group (P<0.05). Bioinformatic analysis revealed that circ-EFCAB2 binds to miR-485-5p to increase the expression level of the ion channel CLCN6, while circ-DROSHA interacts with miR-1252-5p to decrease the expression level of ATP1A2. The dysregulations of circRNAs may reflect the pathogenesis of TLE and circ-EFCAB2 and circ-DROSHA might be potential therapeutic targets and biomarkers in TLE patients. © 2018 The Author(s). Published by S. Karger AG, Basel.

  15. Scintillating properties of frozen new liquid scintillators

    CERN Document Server

    Britvich, G I; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    The light emission from scintillators which are liquid at room temperature was studied in the interval between $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C, where the phase transition from liquid to solid takes place. The light yield measured at $-120$~$^{\\circ}$C is about twice as much as that observed at $+20$~$^{\\circ}$C. By cooling the scintillator from $+20$~$^{\\circ}$C to $-120$~$^{\\circ}$C and then heating it from $-120$~$^{\\circ}$C to $+20$~$^{\\circ}$C, the light yield varies in steps at well defined temperatures, which are different for the cooling and heating processes. These hysteresis phenomena appear to be related to the solvent rather than to the dopant. The decay time of scintillation light was measured at $+20$~$^{\\circ}$C and $-120$~$^{\\circ}$C. Whilst at room temperature most of the light is emitted with a decay time of 6--8 ns, at $-120$~$^{\\circ}$C a slower component, with a decay time of 25--35 ns, becomes important.

  16. Recherche directe à LHCb du boson de Higgs en production associée et contribution au développement du nouveau trajectographe à fibres scintillantes

    CERN Document Server

    Jaton, Pierre

    The framework of this thesis is the Large Hadron collider, more precisely the LHCb experiment. The technical part of this work focusses on the upgrade project of the LHCb experiment, which is planned to be achieved in 2018. The LPHE is responsible for the development of the new Tracker, based on a scintillating fibers technology. A computer simulation of the fiber lattice is presented in order to estimate the efficiency and the resolution of this new detector device. These values are strongly dependent on the transverse $\\theta$ angle of the incident particles. For small values of $\\theta$ (from 0 to 15$^\\circ$), the resolution is found to be around 50 $\\mu m$ and the efficiency is close to 100 %. For $\\theta$ in the range 15 to 25$^\\circ$, the resolution is degrading to about 79 $\\mu m$ but the efficiency remains stable around 100 %. When the angle reaches values from 25 to 35$^\\circ$, the resolution falls down to 335 $\\mu m$ and the efficiency is merely 50 %. These results have to be compared to the experi...

  17. Circular RNA expression profiling of human granulosa cells during maternal aging reveals novel transcripts associated with assisted reproductive technology outcomes.

    Directory of Open Access Journals (Sweden)

    Jing Cheng

    Full Text Available Circular RNAs (circRNAs are a unique class of endogenous RNAs which could be used as potential diagnostic and prognostic biomarkers of many diseases. Our study aimed to investigate circRNA profiles in human granulosa cells (GCs during maternal aging and to uncover age-related circRNA variations that potentially reflect decreased oocyte competence. CircRNAs in GCs from in vitro fertilization (IVF patients with young age (YA, ≤ 30 years and advanced age (AA, ≥ 38 years were profiled by microarray, and validated in 20 paired samples. The correlation between circRNAs expression and clinical characteristics was analyzed in additional 80 samples. Chip-based analysis revealed 46 up-regulated and 11 down-regulated circRNAs in AA samples (fold change > 2.0. Specifically, circRNA_103829, circRNA_103827 and circRNA_104816 were validated to be up-regulated, while circRNA_101889 was down-regulated in AA samples. After adjustment for gonadotropin treatment, only circRNA_103827 and circRNA_104816 levels were positively associated with maternal age (partial r = 0.332, P = 0.045; partial r = 0.473, P = 0.003; respectively. Moreover, circRNA_103827 and circRNA_104816 expressions in GCs were negatively correlated with the number of top quality embryos (r = -0.235, P = 0.036; r = -0.221, P = 0.049; respectively. Receiver operating characteristic (ROC curve analysis indicated that the performance of circRNA_103827 for live birth prediction reached 0.698 [0.570-0.825], with 77.2% sensitivity and 60.9% specificity (P = 0.006, and that of circRNA_104816 was 0.645 [0.507-0.783] (P = 0.043. Bioinformatics analysis revealed that both circRNAs were potentially involved in glucose metabolism, mitotic cell cycle, and ovarian steroidogenesis. Therefore, age-related up-regulation of circRNA_103827 and circRNA_104816 might be potential indicators of compromised follicular micro-environment which could be used to predict IVF prognosis, and improve female infertility

  18. Circular RNA (circRNA) was an important bridge in the switch from the RNA world to the DNA world.

    Science.gov (United States)

    Soslau, Gerald

    2018-06-14

    osmolarity. Circular RNA, circRNA, is proposed as a critical stable RNA molecule that served as the genetic precursor for the switch to DNA and the replication of circRNA by a rolling circle mechanism gave rise to the RNA complexity required for the genetic functions of the cell. The replicating ribocyte would have required protein synthesis as well as RNA replication and a model for non-coded and primordial coded protein synthesis is proposed. Finally, the switch from the RNA to the DNA world would have involved the synthesis of an RNA:DNA hybrid prior to the formation of dsDNA. If the hybrid was a circular molecule that ultimately yielded a circular dsDNA molecule, it could predict that the primordial DNA cell would evolve into a bacterial cell with a single circular chromosome. One would hope that continued speculation of the origin of life will spur new directions of research that may never fully answer the questions of the past but add to our ability to regulate potentially harmful biological events in the present and in the future. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Differential Expression of Circular RNAs in Glioblastoma Multiforme and Its Correlation with Prognosis

    Directory of Open Access Journals (Sweden)

    Junle Zhu

    2017-04-01

    Full Text Available OBJECTIVE: The present study aimed to explore the expression profiles of circular RNAs (circRNAs in glioblastoma multiforme (GBM in an attempt to identify potential core genes in the pathogenesis of this tumor. METHODS: Differentially expressed circRNAs were screened between tumor tissues from five GBM patients and five normal brain samples using Illumina Hiseq. Bioinformatics analysis was used to analyze their potential function. CircBRAF was further detected in different WHO grades glioma tissues and normal brain tissues. Kaplan-Meier curves and multivariate Cox's analysis were used to analyze the association between circBRAF expression level and prognosis of glioma patients. RESULTS: A total of 1411 differentially expressed circRNAs were identified in GBM patients including 206 upregulated circRNAs and 1205 downregulated circRNAs. Differential expression of circRNAs was closely associated with the biological process and molecular function. The downregulated circRNAs were mainly associated with ErbB and Neurotrophin signaling pathways. Moreover, the expression level of circBRAF in normal brain tissues was significantly higher than that in glioma tissues (P < .001. CircBRAF was significantly lower in glioma patients with high pathological grade (WHO III & IV than those with low grade (WHO I & II (P < .001. Cox analysis revealed that high circBRAF expression was an independent biomarker for predicting good progression-free survival and overall survival in glioma patients (HR = 0.413, 95% CI 0.201-0.849; HR = 0.299, 95% CI 0.135-0.661; respectively. CONCLUSION: The present study identified a profile of dysregulated circRNAs in GBM. Bioinformatics analysis showed that dysregulated circRNAs might be associated with tumorigenesis and development of GBM. In addition, circBRAF could severe as a biomarker for predicting pathological grade and prognosis in glioma patients.

  20. Microarray Expression Profile and Functional Analysis of Circular RNAs in Osteosarcoma

    Directory of Open Access Journals (Sweden)

    Weihai Liu

    2017-09-01

    Full Text Available Background/Aims: Osteosarcoma (OS is the most common primary malignant bone tumor in children and adolescents. However, the molecular mechanisms regulating osteosarcoma tumorigenesis and progression are still poorly understood. Circular RNAs (circRNAs have been identified as microRNA sponges and are involved in many important biological processes. This study aims to investigate the global changes in the expression pattern of circRNAs in osteosarcoma and provide a comprehensive understanding of differentially expressed circRNAs. Methods: Microarray based circRNA expression was determined in osteosarcoma cell lines and compared with hFOB1.19, which was used as the normal control. We confirmed the microarray data by real time-qPCR in both osteosarcoma cell lines and tissues. The circRNA/microRNA/mRNA interaction network was predicted using bioinformatics. Gene Ontology analysis and 4 annotation tools for pathway analysis (KEGG, Biocarta, PANTHER and Reactome were used to predict the functions of differentially expressed circRNAs. Results: We revealed a number of differentially expressed circRNAs and 12 of them were confirmed, which suggests a potential role of circRNAs in OS. Among these differentially expressed circRNAs, hsa_circRNA_103801 was up-regulated in both osteosarcoma cell lines and tissues, while hsa_circRNA_104980 was down-regulated. The most likely potential target miRNAs for hsa_circRNA_103801 include hsa-miR-370-3p, hsa-miR-338-3p and hsa-miR-877-3p, while the most potential target miRNAs of hsa_circRNA_104980 consist of hsa-miR-1298-3p and hsa-miR-660-3p. Functional analysis found that hsa_circRNA_103801 was involved in pathways in cancer, such as the HIF-1, VEGF and angiogenesis pathway, the Rap1 signaling pathway and the PI3K-Akt signaling pathway, while hsa_circRNA_104980 was related to some pathways such as the tight junction pathway. Conclusions: This study has identified the comprehensive expression profile of circRNAs in

  1. Circular RNA Profiling and Bioinformatic Modeling Identify Its Regulatory Role in Hepatic Steatosis.

    Science.gov (United States)

    Guo, Xing-Ya; He, Chong-Xin; Wang, Yu-Qin; Sun, Chao; Li, Guang-Ming; Su, Qing; Pan, Qin; Fan, Jian-Gao

    2017-01-01

    Circular RNAs (circRNAs) exhibit a wide range of physiological and pathological activities. To uncover their role in hepatic steatosis, we investigated the expression profile of circRNAs in HepG2-based hepatic steatosis induced by high-fat stimulation. Differentially expressed circRNAs were subjected to validation using QPCR and functional analyses using principal component analysis, hierarchical clustering, target prediction, gene ontology (GO), and pathway annotation, respectively. Bioinformatic integration established the circRNA-miRNA-mRNA regulatory network so as to identify the mechanisms underlying circRNAs' metabolic effect. Here we reported that hepatic steatosis was associated with a total of 357 circRNAs. Enrichment of transcription-related GOs, especially GO: 0006355, GO: 004589, GO: 0045944, GO: 0045892, and GO: 0000122, demonstrated their specific actions in transcriptional regulation. Lipin 1 (LPIN1) was recognized to mediate the transcriptional regulatory effect of circRNAs on metabolic pathways. circRNA-miRNA-mRNA network further identified the signaling cascade of circRNA_021412/miR-1972/LPIN1, which was characterized by decreased level of circRNA_021412 and miR-1972-based inhibition of LPIN1. LPIN1-induced downregulation of long chain acyl-CoA synthetases (ACSLs) expression finally resulted in the hepatosteatosis. These findings identify circRNAs to be important regulators of hepatic steatosis. Transcription-dependent modulation of metabolic pathways may underlie their effects, partially by the circRNA_021412/miR-1972/LPIN1 signaling.

  2. Regulatory Role of Circular RNAs and Neurological Disorders.

    Science.gov (United States)

    Floris, Gabriele; Zhang, Longbin; Follesa, Paolo; Sun, Tao

    2017-09-01

    Circular RNAs (circRNAs) are a class of long noncoding RNAs that are characterized by the presence of covalently linked ends and have been found in all life kingdoms. Exciting studies in regulatory roles of circRNAs are emerging. Here, we summarize classification, characteristics, biogenesis, and regulatory functions of circRNAs. CircRNAs are found to be preferentially expressed along neural genes and in neural tissues. We thus highlight the association of circRNA dysregulation with neurodegenerative diseases such as Alzheimer's disease. Investigation of regulatory role of circRNAs will shed novel light in gene expression mechanisms during development and under disease conditions and may identify circRNAs as new biomarkers for aging and neurodegenerative disorders.

  3. Diverse alternative back-splicing and alternative splicing landscape of circular RNAs

    Science.gov (United States)

    Zhang, Xiao-Ou; Dong, Rui; Zhang, Yang; Zhang, Jia-Lin; Luo, Zheng; Zhang, Jun; Chen, Ling-Ling; Yang, Li

    2016-01-01

    Circular RNAs (circRNAs) derived from back-spliced exons have been widely identified as being co-expressed with their linear counterparts. A single gene locus can produce multiple circRNAs through alternative back-splice site selection and/or alternative splice site selection; however, a detailed map of alternative back-splicing/splicing in circRNAs is lacking. Here, with the upgraded CIRCexplorer2 pipeline, we systematically annotated different types of alternative back-splicing and alternative splicing events in circRNAs from various cell lines. Compared with their linear cognate RNAs, circRNAs exhibited distinct patterns of alternative back-splicing and alternative splicing. Alternative back-splice site selection was correlated with the competition of putative RNA pairs across introns that bracket alternative back-splice sites. In addition, all four basic types of alternative splicing that have been identified in the (linear) mRNA process were found within circRNAs, and many exons were predominantly spliced in circRNAs. Unexpectedly, thousands of previously unannotated exons were detected in circRNAs from the examined cell lines. Although these novel exons had similar splice site strength, they were much less conserved than known exons in sequences. Finally, both alternative back-splicing and circRNA-predominant alternative splicing were highly diverse among the examined cell lines. All of the identified alternative back-splicing and alternative splicing in circRNAs are available in the CIRCpedia database (http://www.picb.ac.cn/rnomics/circpedia). Collectively, the annotation of alternative back-splicing and alternative splicing in circRNAs provides a valuable resource for depicting the complexity of circRNA biogenesis and for studying the potential functions of circRNAs in different cells. PMID:27365365

  4. Identification of Circular RNAs as a Novel Biomarker for Ovarian Endometriosis

    Directory of Open Access Journals (Sweden)

    Xiao-Xuan Xu

    2018-01-01

    Conclusions: This study provides evidence that circRNAs are differentially expressed between eutopic and normal endometrium, which suggests that circRNAs are candidate factors in the activation of endometriosis. circ_0002198 and circ_0004712 may be potential novel biomarkers for the diagnosis of ovarian endometriosis.

  5. Construction and analysis of circular RNA molecular regulatory networks in liver cancer.

    Science.gov (United States)

    Ren, Shuangchun; Xin, Zhuoyuan; Xu, Yinyan; Xu, Jianting; Wang, Guoqing

    2017-01-01

    Liver cancer is the sixth most prevalent cancer, and the third most frequent cause of cancer-related deaths. Circular RNAs (circRNAs), a kind of special endogenous ncRNAs, have been coming back to the forefront of cancer genomics research. In this study, we used a systems biology approach to construct and analyze the circRNA molecular regulatory networks in the context of liver cancer. We detected a total of 127 differentially expressed circRNAs and 3,235 differentially expressed mRNAs. We selected the top-5 upregulated circRNAs to construct a circRNA-miRNA-mRNA network. We enriched the pathways and gene ontology items and determined their participation in cancer-related pathways such as p53 signaling pathway and pathways involved in angiogenesis and cell cycle. Quantitative real-time PCR was performed to verify the top-five circRNAs. ROC analysis showed circZFR, circFUT8, circIPO11 could significantly distinguish the cancer samples, with an AUC of 0.7069, 0.7575, and 0.7103, respectively. Our results suggest the circRNA-miRNA-mRNA network may help us further understand the molecular mechanisms of tumor progression in liver cancer, and reveal novel biomarkers and therapeutic targets.

  6. Profiling and bioinformatic analysis of circular RNA expression regulated by c-Myc.

    Science.gov (United States)

    Gou, Qiheng; Wu, Ke; Zhou, Jian-Kang; Xie, Yuxin; Liu, Lunxu; Peng, Yong

    2017-09-22

    The c-Myc transcription factor is involved in cell proliferation, cell cycle and apoptosis by activating or repressing transcription of multiple genes. Circular RNAs (circRNAs) are widely expressed non-coding RNAs participating in the regulation of gene expression. Using a high-throughput microarray assay, we showed that Myc regulates the expression of certain circRNAs. A total of 309 up- and 252 down-regulated circRNAs were identified. Among them, randomly selected 8 circRNAs were confirmed by real-time PCR. Subsequently, Myc-binding sites were found to generally exist in the promoter regions of differentially expressed circRNAs. Based on miRNA sponge mechanism, we constructed circRNAs/miRNAs network regulated by Myc, suggesting that circRNAs may widely regulate protein expression through miRNA sponge mechanism. Lastly, we took advantage of Gene Ontology and KEGG analyses to point out that Myc-regulated circRNAs could impact cell proliferation through affecting Ras signaling pathway and pathways in cancer. Our study for the first time demonstrated that Myc transcription factor regulates the expression of circRNAs, adding a novel component of the Myc tumorigenic program and opening a window to investigate the function of certain circRNAs in tumorigenesis.

  7. Microarray expression profile of circular RNAs in chronic thromboembolic pulmonary hypertension

    Science.gov (United States)

    Miao, Ran; Wang, Ying; Wan, Jun; Leng, Dong; Gong, Juanni; Li, Jifeng; Liang, Yan; Zhai, Zhenguo; Yang, Yuanhua

    2017-01-01

    Abstract Background: Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare but debilitating and life-threatening complication of acute pulmonary embolism. Circular RNAs (circRNAs), presenting as covalently closed continuous loops, are RNA molecules with covalently joined 3′- and 5′-ends formed by back-splicing events. circRNAs may be significant biological molecules to understand disease mechanisms and to identify biomarkers for disease diagnosis and therapy. The aim of this study was to investigate the potential roles of circRNAs in CTEPH. Methods: Ten human blood samples (5 each from CTEPH and control groups) were included in the Agilent circRNA chip. The differentially expressed circRNAs were evaluated using t test, with significance set at a P value of < .05. A functional enrichment analysis for differentially expressed circRNAs was performed using DAVID online tools, and a Kyoto Encyclopedia of Genes and Genomes pathway enrichment analysis for target genes of miRNAs was performed using the R package clusterProfiler. Furthermore, miRNAs that interacted with differentially expressed circRNAs were predicted using the miRanda package. mRNAs that had clear biological functions and were regulated by miRNAs were predicted using miRWalk2.0 and then combined into a circRNA–miRNA–mRNA network. Results: In total, 351 differentially expressed circRNAs (122 upregulated and 229 downregulated) between CTEPH and control groups were obtained; among these circRNAs, hsa_circ_0002062 and hsa_circ_0022342 might be important because they can regulate 761 (e.g., hsa-miR-942–5p) and 453 (e.g., hsa-miR-940) miRNAs, respectively. Target genes (e.g., cyclin-dependent kinase 6) of hsa-miR-942–5p were mainly enriched in cancer-related pathways, whereas target genes (e.g., CRK-Like Proto-Oncogene, Adaptor Protein) of hsa-miR-940 were enriched in the ErbB signaling pathway. Therefore, these pathways are potentially important in CTEPH. Conclusions: Our findings

  8. Lung Cancer-Specific Circular RNAs as Biomarkers

    Science.gov (United States)

    2017-08-01

    determine whether differential expression of circular RNAs can also be detected in cell culture models. Third, we will determine whether circular RNAs can...four of them as representative differentially expressed circRNAs in Table 1. For example , hsa_circRNA_400633 and hsa_circRNA_101100 were upregulated...sequence for hsa_circRNA_400633 and hsa_circRNA_101100, as shown in Figs. 1 and 2 as an example . The top part is the actual sequence and the

  9. circHIPK2-mediated σ-1R promotes endoplasmic reticulum stress in human pulmonary fibroblasts exposed to silica.

    Science.gov (United States)

    Cao, Zhouli; Xiao, Qingling; Dai, Xiaoniu; Zhou, Zewei; Jiang, Rong; Cheng, Yusi; Yang, Xiyue; Guo, Huifang; Wang, Jing; Xi, Zhaoqing; Yao, Honghong; Chao, Jie

    2017-12-13

    Silicosis is characterized by fibroblast accumulation and excessive deposition of extracellular matrix. Although the roles of SiO 2 -induced chemokines and cytokines released from alveolar macrophages have received significant attention, the direct effects of SiO 2 on protein production and functional changes in pulmonary fibroblasts have been less extensively studied. Sigma-1 receptor, which has been associated with cell proliferation and migration in the central nervous system, is expressed in the lung, but its role in silicosis remains unknown. To elucidate the role of sigma-1 receptor in fibrosis induced by silica, both the upstream molecular mechanisms and the functional effects on cell proliferation and migration were investigated. Both molecular biological assays and pharmacological techniques, combined with functional experiments, such as migration and proliferation, were applied in human pulmonary fibroblasts from adults to analyze the molecular and functional changes induced by SiO 2 . SiO 2 induced endoplasmic reticulum stress in association with enhanced expression of sigma-1 receptor. Endoplasmic reticulum stress promoted migration and proliferation of human pulmonary fibroblasts-adult exposed to SiO 2 , inducing the development of silicosis. Inhibition of sigma-1 receptor ameliorated endoplasmic reticulum stress and fibroblast functional changes induced by SiO 2 . circHIPK2 is involved in the regulation of sigma-1 receptor in human pulmonary fibroblasts-adult exposed to SiO 2 . Our study elucidated a link between SiO 2 -induced fibrosis and sigma-1 receptor signaling, thereby providing novel insight into the potential use of sigma-1 receptor/endoplasmic reticulum stress in the development of novel therapeutic strategies for silicosis treatment.

  10. Accelerator mass spectrometry 14C dating of lime mortars: Methodological aspects and field study applications at CIRCE (Italy)

    Science.gov (United States)

    Marzaioli, Fabio; Nonni, Sara; Passariello, Isabella; Capano, Manuela; Ricci, Paola; Lubritto, Carmine; De Cesare, Nicola; Eramo, Giacomo; Quirós Castillo, Juan Antonio; Terrasi, Filippo

    2013-01-01

    Centre for Isotopic Research on Cultural and Environmental heritage (CIRCE) has, recently, obtained some promising results in testing the feasibility of mortar radiocarbon dating by means of an ad hoc developed purification procedure (CryoSoniC: Cryobraking, Sonication, Centrifugation) applied to a series of laboratory mortars. Observed results encouraged CryoSoniC accuracy evaluation on genuine mortars sampled from archeological sites of known or independently constrained age (i.e., other 14C dates on different materials). In this study, some 14C measurements performed on genuine mortars will be discussed and compared with independently estimated (i.e., radiocarbon/archaeometrical dating) absolute chronologies of two Spanish sites. Observed results confirm the agreement of the CryoSoniC mortar dates with the archaeological expectations for both examined cases. Several authors reported the possibility of obtaining accurate radiocarbon dates of mortar matrices by analyzing lime lumps: binder-related particles of different sizes exclusively composed of calcium carbonate. In this paper, preliminary data for the absolute chronology reconstruction of the Basilica of the cemetery complex of Ponte della Lama (Canosa di Puglia, Italy) based on lime lumps will also be discussed. Dating accuracy will be quantified by comparing 14C data on mortar lime lumps from a funerary inscription of known age found near the Basilica, in the same study site. For this site, a comparison between absolute chronologies performed by bulk and CryoSoniC purified lime lumps, and charcoal incased in mortars (when found) will also be discussed. Observed results for this site provide evidence of how bulk lime lump dating may introduce systematic overestimations of the analyzed sample while CryoSoniC purification allows accurate dating.

  11. Planck intermediate results. XII: Diffuse Galactic components in the Gould Belt System

    DEFF Research Database (Denmark)

    Planck Collaboration,; Ade, P. A. R.; Aghanim, N.

    2013-01-01

    We perform an analysis of the diffuse low-frequency Galactic components in the Southern part of the Gould Belt system (130^\\circ\\leq l\\leq 230^\\circ and -50^\\circ\\leq b\\leq -10^\\circ). Strong ultra-violet (UV) flux coming from the Gould Belt super-association is responsible for bright diffuse...

  12. Circular RNA alterations are involved in resistance to avian leukosis virus subgroup-J-induced tumor formation in chickens.

    Science.gov (United States)

    Zhang, Xinheng; Yan, Yiming; Lei, Xiaoya; Li, Aijun; Zhang, Huanmin; Dai, Zhenkai; Li, Xinjian; Chen, Weiguo; Lin, Wencheng; Chen, Feng; Ma, Jingyun; Xie, Qingmei

    2017-05-23

    Avian leukosis virus subgroup (ALV-J) is an oncogenic neoplasm-inducing retrovirus that causes significant economic losses in the poultry industry. Recent studies have demonstrated circular RNAs (circRNAs) are implicated in pathogenic processes; however, no research has indicated circRNAs are involved in resistance to disease. In this study, over 1800 circRNAs were detected by circRNA sequencing of liver tissues from ALV-J-resistant (n = 3) and ALV-J-susceptible chickens (n = 3). 32 differentially expressed circRNAs were selected for analyzing including 12 upregulated in ALV-J-resistant chickens and 20 upregulated in ALV-J-susceptible chickens, besides, the top five microRNAs (miRNAs) for 12 upregulated circRNAs in ALV-J-resistant chickens were analyzed. Gene ontology and KEGG pathway analyses were performed for miRNA target genes, the predicted genes were mainly involved in immune pathways. This study provides the first evidence that circRNA alterations are involved in resistance to ALV-J-induced tumor formation. We propose circRNAs may help to mediate tumor induction and development in chickens.

  13. Microarray Expression Profile of Circular RNAs in Heart Tissue of Mice with Myocardial Infarction-Induced Heart Failure

    Directory of Open Access Journals (Sweden)

    Hong-Jin Wu

    2016-06-01

    Full Text Available Background/Aims: Myocardial infarction (MI is a serious complication of atherosclerosis associated with increasing mortality attributable to heart failure. This study is aimed to assess the global changes in and characteristics of the transcriptome of circular RNAs (circRNAs in heart tissue during MI induced heart failure (HF. Methods: Using a post-myocardial infarction (MI model of HF in mice, we applied microarray assay to examine the transcriptome of circRNAs deregulated in the heart during HF. We confirmed the changes in circRNAs by quantitative PCR. Results: We revealed and confirmed a number of circRNAs that were deregulated during HF, which suggests a potential role of circRNAs in HF. Conclusions: The distinct expression patterns of circulatory circRNAs during HF indicate that circRNAs may actively respond to stress and thus serve as biomarkers of HF diagnosis and treatment.

  14. Analysis of human ES cell differentiation establishes that the dominant isoforms of the lncRNAs RMST and FIRRE are circular.

    Science.gov (United States)

    Izuogu, Osagie G; Alhasan, Abd A; Mellough, Carla; Collin, Joseph; Gallon, Richard; Hyslop, Jonathon; Mastrorosa, Francesco K; Ehrmann, Ingrid; Lako, Majlinda; Elliott, David J; Santibanez-Koref, Mauro; Jackson, Michael S

    2018-04-20

    Circular RNAs (circRNAs) are predominantly derived from protein coding genes, and some can act as microRNA sponges or transcriptional regulators. Changes in circRNA levels have been identified during human development which may be functionally important, but lineage-specific analyses are currently lacking. To address this, we performed RNAseq analysis of human embryonic stem (ES) cells differentiated for 90 days towards 3D laminated retina. A transcriptome-wide increase in circRNA expression, size, and exon count was observed, with circRNA levels reaching a plateau by day 45. Parallel statistical analyses, controlling for sample and locus specific effects, identified 239 circRNAs with expression changes distinct from the transcriptome-wide pattern, but these all also increased in abundance over time. Surprisingly, circRNAs derived from long non-coding RNAs (lncRNAs) were found to account for a significantly larger proportion of transcripts from their loci of origin than circRNAs from coding genes. The most abundant, circRMST:E12-E6, showed a > 100X increase during differentiation accompanied by an isoform switch, and accounts for > 99% of RMST transcripts in many adult tissues. The second most abundant, circFIRRE:E10-E5, accounts for > 98% of FIRRE transcripts in differentiating human ES cells, and is one of 39 FIRRE circRNAs, many of which include multiple unannotated exons. Our results suggest that during human ES cell differentiation, changes in circRNA levels are primarily globally controlled. They also suggest that RMST and FIRRE, genes with established roles in neurogenesis and topological organisation of chromosomal domains respectively, are processed as circular lncRNAs with only minor linear species.

  15. Accelerator mass spectrometry {sup 14}C dating of lime mortars: Methodological aspects and field study applications at CIRCE (Italy)

    Energy Technology Data Exchange (ETDEWEB)

    Marzaioli, Fabio, E-mail: fabio.marzaioli@unina2.it [CIRCE, INNOVA and Seconda Universita degli Studi di Napoli, Dipartimento di Scienze Ambientali, Caserta (Italy); Nonni, Sara, E-mail: sara.nonni@uniroma1.it [Dipartimento di Scienze della Terra, ' Sapienza' Universita di Roma (Italy); Passariello, Isabella, E-mail: isabella.passariello@unina2.it [CIRCE, INNOVA and Seconda Universita degli Studi di Napoli, Dipartimento di Scienze Ambientali, Caserta (Italy); Capano, Manuela, E-mail: manuela.capano@unina2.it [CIRCE, INNOVA and Dipartimento di Studio delle Componenti Culturali del Territorio, Seconda Universita degli Studi di Napoli, Santa Maria Capua Vetere, Caserta (Italy); Ricci, Paola, E-mail: paola.ricci@unina2.it [CIRCE, INNOVA and Seconda Universita degli Studi di Napoli, Dipartimento di Scienze Ambientali, Caserta (Italy); Lubritto, Carmine, E-mail: carmine.lubritto@unina2.it [CIRCE, INNOVA and Seconda Universita degli Studi di Napoli, Dipartimento di Scienze Ambientali, Caserta (Italy); De Cesare, Nicola, E-mail: nicola.decesare@unina2.it [CIRCE, INNOVA and Seconda Universita degli Studi di Napoli, Dipartimento di Scienze della Vita, Caserta (Italy); Eramo, Giacomo, E-mail: giacomo.eramo@uniba.it [Dipartimento di Scienze della Terra e Geoambientali, Universita degli Studi di Bari ' Aldo Moro' , Bari (Italy); Quiros Castillo, Juan Antonio, E-mail: quiros.castillo@ehu.es [Universidad del Pais Vasco-Euskal Herriko Unibertsitatea, Dipartimento di Geografia, Prehistoria y Arqueologia, Vitoria-Gasteiz (Spain); and others

    2013-01-15

    Centre for Isotopic Research on Cultural and Environmental heritage (CIRCE) has, recently, obtained some promising results in testing the feasibility of mortar radiocarbon dating by means of an ad hoc developed purification procedure (CryoSoniC: Cryobraking, Sonication, Centrifugation) applied to a series of laboratory mortars. Observed results encouraged CryoSoniC accuracy evaluation on genuine mortars sampled from archeological sites of known or independently constrained age (i.e., other {sup 14}C dates on different materials). In this study, some {sup 14}C measurements performed on genuine mortars will be discussed and compared with independently estimated (i.e., radiocarbon/archaeometrical dating) absolute chronologies of two Spanish sites. Observed results confirm the agreement of the CryoSoniC mortar dates with the archaeological expectations for both examined cases. Several authors reported the possibility of obtaining accurate radiocarbon dates of mortar matrices by analyzing lime lumps: binder-related particles of different sizes exclusively composed of calcium carbonate. In this paper, preliminary data for the absolute chronology reconstruction of the Basilica of the cemetery complex of Ponte della Lama (Canosa di Puglia, Italy) based on lime lumps will also be discussed. Dating accuracy will be quantified by comparing {sup 14}C data on mortar lime lumps from a funerary inscription of known age found near the Basilica, in the same study site. For this site, a comparison between absolute chronologies performed by bulk and CryoSoniC purified lime lumps, and charcoal incased in mortars (when found) will also be discussed. Observed results for this site provide evidence of how bulk lime lump dating may introduce systematic overestimations of the analyzed sample while CryoSoniC purification allows accurate dating.

  16. Circular RNAs: Biogenesis, Function and Role in Human Diseases

    Directory of Open Access Journals (Sweden)

    John Greene

    2017-06-01

    Full Text Available Circular RNAs (circRNAs are currently classed as non-coding RNA (ncRNA that, unlike linear RNAs, form covalently closed continuous loops and act as gene regulators in mammals. They were originally thought to represent errors in splicing and considered to be of low abundance, however, there is now an increased appreciation of their important function in gene regulation. circRNAs are differentially generated by backsplicing of exons or from lariat introns. Unlike linear RNA, the 3′ and 5′ ends normally present in an RNA molecule have been joined together by covalent bonds leading to circularization. Interestingly, they have been found to be abundant, evolutionally conserved and relatively stable in the cytoplasm. These features confer numerous potential functions to circRNAs, such as acting as miRNA sponges, or binding to RNA-associated proteins to form RNA-protein complexes that regulate gene transcription. It has been proposed that circRNA regulate gene expression at the transcriptional or post-transcriptional level by interacting with miRNAs and that circRNAs may have a role in regulating miRNA function in cancer initiation and progression. circRNAs appear to be more often downregulated in tumor tissue compared to normal tissue and this may be due to (i errors in the back-splice machinery in malignant tissues, (ii degradation of circRNAs by deregulated miRNAs in tumor tissue, or (iii increasing cell proliferation leading to a reduction of circRNAs. circRNAs have been identified in exosomes and more recently, chromosomal translocations in cancer have been shown to generate aberrant fusion-circRNAs associated with resistance to drug treatments. In addition, though originally thought to be non-coding, there is now increasing evidence to suggest that select circRNAs can be translated into functional proteins. Although much remains to be elucidated about circRNA biology and mechanisms of gene regulation, these ncRNAs are quickly emerging as

  17. Searching for a Cosmological Preferred Direction with 147 Rotationally Supported Galaxies

    Science.gov (United States)

    Zhou, Yong; Zhao, Zhi-Chao; Chang, Zhe

    2017-10-01

    It is well known that the Milgrom’s modified Newtonian dynamics (MOND) explains well the mass discrepancy problem in galaxy rotation curves. The MOND predicts a universal acceleration scale below which the Newtonian dynamics is still invalid. We get the universal acceleration scale of 1.02 × 10-10 m s-2 by using the Spitzer Photometry and Accurate Rotation Curves (SPARC) data set. Milgrom suggested that the acceleration scale may be a fingerprint of cosmology on local dynamics and related to the Hubble constant g † ˜ cH 0. In this paper, we use the hemisphere comparison method with the SPARC data set to investigate possible spatial anisotropy on the acceleration scale. It is found that the hemisphere of the maximum acceleration scale is in the direction (l,b)=(175\\buildrel{\\circ}\\over{.} {5}-{10^\\circ }+{6^\\circ }, -6\\buildrel{\\circ}\\over{.} {5}-{3^\\circ }+{9^\\circ }) with g †,max = 1.10 × 10-10 m s-2, while the hemisphere of the minimum acceleration scale is in the opposite direction (l,b)=(355\\buildrel{\\circ}\\over{.} {5}-{10^\\circ }+{6^\\circ }, 6\\buildrel{\\circ}\\over{.} {5}-{9^\\circ }+{3^\\circ }) with g †,min = 0.76 × 10-10 m s-2. The level of anisotropy reaches up to 0.37 ± 0.04. Robust tests show that such an anisotropy cannot be reproduced by a statistically isotropic data set. We also show that the spatial anisotropy on the acceleration scale is less correlated with the non-uniform distribution of the SPARC data points in the sky. In addition, we confirm that the anisotropy of the acceleration scale does not depend significantly on other physical parameters of the SPARC galaxies. It is interesting to note that the maximum anisotropy direction found in this paper is close with other cosmological preferred directions, particularly the direction of the “Australia dipole” for the fine structure constant.

  18. Circular RNA: a new star in neurological diseases.

    Science.gov (United States)

    Li, Tao-Ran; Jia, Yan-Jie; Wang, Qun; Shao, Xiao-Qiu; Lv, Rui-Juan

    2017-08-01

    Circular RNAs (circRNAs) are novel endogenous non-coding RNAs characterized by the presence of a covalent bond linking the 3' and 5' ends generated by backsplicing. In this review, we summarize a number of the latest theories regarding the biogenesis, properties and functions of circRNAs. Specifically, we focus on the advancing characteristics and functions of circRNAs in the brain and neurological diseases. CircRNAs exhibit the characteristics of species conservation, abundance and tissue/developmental-stage-specific expression in the brain. We also describe the relationship between circRNAs and several neurological diseases and highlight their functions in neurological diseases.

  19. Caracterización de la curva de termoluminiscencia del circón a partir de su contenido radiactivo y del análisis térmico diferencial

    Directory of Open Access Journals (Sweden)

    Correcher, V.

    2003-12-01

    Full Text Available Zircon (ZrSiO4 is a mineral widely employed in the production of refractories, pigments, glazed tiles etc. The high radioactive content of this mineral stems from the presence of natural alpha emitters as U and Th. The radioactive activity of the 238U, 235U and 234U, 228Th, 230Th and 232Th radionuclides was measured by alpha spectrometry after isolation by radiochemical techniques. The alpha-emitters uranium and thorium irradiates internally the ceramic modifying the luminescence properties, this involves a potential use for dosimetric purposes. The thermoluminescence (TL glow curve intensity of zircon is higher than the observed in other aluminosilicates measured under the same conditions. The TL maxima appearing at 280, 360 and 445oC are fairly well correlated with the differential thermal analysis (DTA. It suggests that this TL peaks could be linked to: (1 partial processes of local phase transitions and (2 alkali self-diffusion dehydroxylation phenomena when the sample is heated during the analytical measurement routine.

    El circón (ZrSiO4 es un material que se utiliza habitualmente en la fabricación de refractarios, esmaltes para azulejos, pigmentos, etc. Este mineral tiene un alto contenido radiactivo debido a la presencia de emisores alfa naturales como U y Th. En este trabajo se ha determinado el contenido isotópico de estos radionucleidos (238U, 235U y 234U, 228Th, 230Th y 232Th utilizando técnicas de separación radioquímicas y cuantificando la actividad mediante espectrometría alfa. Estos radioisótopos naturales producen una irradiación interna en el material cerámico que se manifiesta en sus propiedades luminiscentes lo que implica que pueda ser utilizado con fines dosimétricos. Se ha observado que la curva de termoluminiscencia (TL del circón muestra una intensidad considerablemente mayor (más de un orden de magnitud que la de otros silicatos medidos en idénticas condiciones. Los máximos que aparecen en la curva

  20. Identification of circular RNA in the Bombyx mori silk gland.

    Science.gov (United States)

    Gan, Huaiyan; Feng, Tieshan; Wu, Yuqian; Liu, Chun; Xia, Qingyou; Cheng, Tingcai

    2017-10-01

    Bombyx mori is an economically important holometabolous lepidopteran insect. In B. mori endogenous noncoding RNAs such as microRNAs (miRNAs) and Piwi-interacting RNAs play crucial biological functions in metamorphosis and sex determination. In addition, circular RNAs (circRNAs) have been recently identified as noncoding RNAs in most common model organisms and show potential as gene regulators. However, to date, there have been few studies on the circRNAs present in the B. mori genome conducted to date. Here, we identified 3916 circRNAs by deep circular transcriptome sequencing using the silk gland of B. mori. 3155 circRNAs were found to be derived from 1727 parental genes. The circRNAs displayed tissue-specific expression between the middle silk gland (MSG) and posterior silk gland (PSG), with 2532 and 880 being upregulated circRNAs in the MSG and PSG, respectively. Gene Ontology and Kyoto Encyclopedia of Genes and Genomes pathway analyses showed that the parental genes from the MSG and PSG were generally annotated to similar categories and pathways. The interaction network of circRNAs and miRNAs showed that circRNAs might act as miRNA sponges or interact with miRNAs in some other way. Overall, the results revealed the complicated patterns of circRNAs in the B. mori silk gland providing a new angle from which to explore the mechanisms of complex gene regulation and efficient silk protein synthesis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Spatio-temporal regulation of circular RNA expression during porcine embryonic brain development

    DEFF Research Database (Denmark)

    Venø, Morten T; Hansen, Thomas B; Venø, Susanne T

    2015-01-01

    BACKGROUND: Recently, thousands of circular RNAs (circRNAs) have been discovered in various tissues and cell types from human, mouse, fruit fly and nematodes. However, expression of circRNAs across mammalian brain development has never been examined. RESULTS: Here we profile the expression of circ......RNA in five brain tissues at up to six time-points during fetal porcine development, constituting the first report of circRNA in the brain development of a large animal. An unbiased analysis reveals a highly complex regulation pattern of thousands of circular RNAs, with a distinct spatio-temporal expression...... are functionally conserved between mouse and human. Furthermore, we observe that "hot-spot" genes produce multiple circRNA isoforms, which are often differentially expressed across porcine brain development. A global comparison of porcine circRNAs reveals that introns flanking circularized exons are longer than...

  2. Étude expérimentale du comportement cyclique d'un acier du type 316 L sous chargement multiaxial complexe en traction-torsion-pressions interne et externe

    Science.gov (United States)

    Bocher, L.; Delobelle, P.

    1997-09-01

    This paper is concerned with the experimental determination of the behaviour of a 316 L austenitic stainless steel at room temperature and under non proportional cyclic strainings in tension-torsion- internal and external pressures. The two or three sinusoïdal strains were applied both in and out-of-phase and the main investigations deal with the additional hardening due to multiaxiality of the loadings. Typical stabilized hysteresis loops are presented. With respect to the maximum additional hardening the different tests can be classified as follows : in phase tests, out-of-phase internal-external pressures tests, out-of-phase tension-torsion tests and finally tension-torsion-pressure with significant phase angles A device is presented which allows cyclic tests to be performed on tubes for loadings in tension-torsion-internal and external pressures. It is composed of a medium pressure chamber enclosing the gage length of the test specimen, directly fixed on the specimen and connected to two pressure regulators. The specimen is also fastened to the jaws of a hydraulic tensile-torsion machine through two extension rods. The entire device is controlled with the help of strain gauges set directly on the gage zone of the test specimen. Different tests have been performed at ambient temperature on an austenitic stainless steel which has the particularity of presenting a strong supplementary hardening connected to the non-radiality of the loadings. The influence of the phase shift parameters, namely the angles δ and \\varphi (δ: tension-torsion, \\varphi: tension-pressures) for two or three cyclic sinusoïdal components and for a total equivalent strain amplitude level imposed at 0.4% was studied. The ratios of the maximum strain amplitudes were respectively fixed at r_2 = 1 and r_1 = ± 1 (r_2: tension-torsion and r_1: tension-pressures). These tests allowed both the hypotheses made in stress calculations and the whole of the experimental set up to be validated. They

  3. Effect of Circular RNA UBAP2 Silencing on Proliferation and Invasion of Human Lung Cancer A549 Cells and Its Mechanism

    Directory of Open Access Journals (Sweden)

    Yujing YIN

    2017-12-01

    Full Text Available Background and objective It has been proven that circular RNAs (circRNAs play an important role on the process of many types cancer and circUBAP2 was a cancer-promoting circRNA, however, the role and mechanism in lung cancer was not clear. The aim of this study is to investigate the effects of circUBAP2 on cell proliferation and invasion of human lung cancer A549 cells. Methods CCK-8 assay was employed to detect the effect of circUBAP2 sliencing on cell proliferation of A549 cells. Fow cytometry was applied to detect the impact of circUBAP2 sliencing on cell cycle and cell anoikis, and Transwell invasion assay was applied to determine cell invasion of A549 cells. We also employed Western blot and Real-time PCR to determine the expressions of CDK6, cyclin D1, p27 and c-IAP1, Bcl-2, Survivin, Bax, FAK, Rac1 and MMP2, and the activities of JNK and ERK1/2, luciferase report gene assay was used to detect the targets. Results CCK-8 assay showed that the inhibition of cell proliferation in the circUBAP2-siRNA group compared to untreated group and siRNA control group. Results of cell cycle detected by flow cytometry showed that cell cycle arrestd at G0/G1 after circUBAP2 silencing, cell apoptosis rate increased also. We also found that after circUBAP2 silencing, cell invasion of A549 cells was significantly inhibited. Western blot and Real-time PCR results showed that expression of CDK6, cyclin D1, c-IAP1, Bcl-2, Survivin, FAK, Rac1 and MMP2 were down-regulated, and the expression of p27 and Bax were up-regulated. Moreover, the activities of JNK and ERK1/2 were inhibited because of circUBAP2 silencing, the target genes were miR-339-5p, miR-96-3p and miR-135b-3p. Conclusion CircUBAP2 plays an important role in the proliferation and invasion of human lung cancer. Silencing of circUBAP2 might be a novel target for molecular targeted therapy of patients with lung cancer.

  4. Circular RNAs

    DEFF Research Database (Denmark)

    Han, Yi-Neng; Xia, Shengqiang; Zhang, Yuan-Yuan

    2017-01-01

    Circular RNAs (circRNAs) are a novel type of universal and diverse endogenous noncoding RNAs (ncRNAs) and they form a covalently closed continuous loop without 5' or 3' tails unlike linear RNAs. Most circRNAs are presented with characteristics of abundance, stability, conservatism, and often exhi...... and expression regulators, RBP sponges in cancer as well as current research methods of circRNAs, providing evidence for the significance of circRNAs in cancer diagnosis and clinical treatment....

  5. Circular RNA Signature Predicts Gemcitabine Resistance of Pancreatic Ductal Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Feng Shao

    2018-06-01

    Full Text Available Gemcitabine resistance is currently the main problem of chemotherapy for advanced pancreatic cancer patients. The resistance is thought to be caused by altered drug metabolism or reduced apoptosis of cancer cells. However, the underlying mechanism of Gemcitabine resistance in pancreatic cancer remains unclear. In this study, we established Gemcitabine resistant PANC-1 (PANC-1-GR cell lines and compared the circular RNAs (circRNAs profiles between PANC-1 cells and PANC-1-GR cells by RNA sequencing. Differentially expressed circRNAs were demonstrated using scatter plot and cluster heatmap analysis. Gene ontology and pathway analysis were performed to systemically map the genes which are functionally associated to those differentially expressed circRNAs identified from our data. The expression of the differentially expressed circRNAs picked up by RNAseq in PANC-1-GR cells was further validated by qRT-PCR and two circRNAs were eventually identified as the most distinct targets. Consistently, by analyzing plasma samples form pancreatic ductal adenocarcinoma (PDAC patients, the two circRNAs showed more significant expression in the Gemcitabine non-responsive patients than the responsive ones. In addition, we found that silencing of the two circRNAs could restore the sensitivity of PANC-1-GR cells to Gemcitabine treatment, while over-expression of them could increase the resistance of normal PANC-1 and MIA PACA-2 cells, suggesting that they might serve as drug targets for Gemcitabine resistance. Furthermore, the miRNA interaction networks were also explored based on the correlation analysis of the target microRNAs of these two circRNAs. In conclusion, we successfully established new PANC-1-GR cells, systemically characterized the circRNA and miRNA profiles, and identified two circRNAs as novel biomarkers and potential therapeutic targets for Gemcitabine non-responsive PDAC patients.

  6. Deuterated silicon nitride photonic devices for broadband optical frequency comb generation

    Science.gov (United States)

    Chiles, Jeff; Nader, Nima; Hickstein, Daniel D.; Yu, Su Peng; Briles, Travis Crain; Carlson, David; Jung, Hojoong; Shainline, Jeffrey M.; Diddams, Scott; Papp, Scott B.; Nam, Sae Woo; Mirin, Richard P.

    2018-04-01

    We report and characterize low-temperature, plasma-deposited deuterated silicon nitride thin films for nonlinear integrated photonics. With a peak processing temperature less than 300$^\\circ$C, it is back-end compatible with pre-processed CMOS substrates. We achieve microresonators with a quality factor of up to $1.6\\times 10^6 $ at 1552 nm, and $>1.2\\times 10^6$ throughout $\\lambda$ = 1510 -- 1600 nm, without annealing or stress management. We then demonstrate the immediate utility of this platform in nonlinear photonics by generating a 1 THz free spectral range, 900-nm-bandwidth modulation-instability microresonator Kerr comb and octave-spanning, supercontinuum-broadened spectra.

  7. Circular RNA expression is abundant and correlated to aggressiveness in early-stage bladder cancer

    DEFF Research Database (Denmark)

    Okholm, Trine Line Hauge; Nielsen, Morten Muhlig; Hamilton, Mark

    2017-01-01

    The functions and biomarker potential of circular RNAs (circRNAs) in various cancer types are a rising field of study, as emerging evidence relates circRNAs to tumorigenesis. Here, we profiled the expression of circRNAs in 457 tumors from patients with non-muscle-invasive bladder cancer (NMIBC). We...

  8. Circular RNAs in cancer

    DEFF Research Database (Denmark)

    Kristensen, L S; Hansen, T B; Venø, M T

    2018-01-01

    Circular RNA (circRNA) is a novel member of the noncoding cancer genome with distinct properties and diverse cellular functions, which is being explored at a steadily increasing pace. The list of endogenous circRNAs involved in cancer continues to grow; however, the functional relevance of the vast...... for circRNA cancer research and current caveats, which must be addressed to facilitate the translation of basic circRNA research into clinical use.Oncogene advance online publication, 9 October 2017; doi:10.1038/onc.2017.361....

  9. Circular RNA expression profiles in hippocampus from mice with perinatal glyphosate exposure.

    Science.gov (United States)

    Yu, Ning; Tong, Yun; Zhang, Danni; Zhao, Shanshan; Fan, Xinli; Wu, Lihui; Ji, Hua

    2018-05-19

    Glyphosate is the active ingredient in numerous herbicide formulations. The roles of glyphosate in embryo-toxicity and neurotoxicity have been reported in human and animal models. Recently, several studies have reported evidence linking neurodevelopmental disorders (NDDs) with gestational glyphosate exposure. However, the role of glyphosate in neuronal development is still not fully understood. Our previous study found that perinatal glyphosate exposure resulted in differential microRNA expression in the prefrontal cortex of mouse offspring. However, the mechanism of glyphosate-induced neurotoxicity in the developing brain is still not fully understood. Considering the pivotal role of Circular RNAs (circRNAs) in the regulation of gene expression, a circRNA microarray method was used in this study to investigate circRNA expression changes in the hippocampus of mice with perinatal glyphosate exposure. The circRNA microarrays revealed that 663 circRNAs were significantly altered in the perinatal glyphosate exposure group compared with the control group. Among them, 330 were significantly upregulated, and the other 333 were downregulated. Furthermore, the relative expression levels of mmu-circRNA-014015, mmu-circRNA-28128 and mmu-circRNA-29837 were verified using quantitative real-time polymerase chain reaction (qRT-PCR). Gene Ontology (GO) and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathway analyses demonstrated that stress-associated steroid metabolism pathways, such as aldosterone synthesis and secretion pathways, may be involved in the neurotoxicity of glyphosate. These results showed that circRNAs are aberrantly expressed in the hippocampus of mice with perinatal glyphosate exposure and play potential roles in glyphosate-induced neurotoxicity. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. FUCHS—towards full circular RNA characterization using RNAseq

    Directory of Open Access Journals (Sweden)

    Franziska Metge

    2017-02-01

    Full Text Available Circular RNAs (circRNAs belong to a recently re-discovered species of RNA that emerge during RNA maturation through a process called back-splicing. A downstream 5′ splice site is linked to an upstream 3′ splice site to form a circular transcript instead of a canonical linear transcript. Recent advances in next-generation sequencing (NGS have brought circRNAs back into the focus of many scientists. Since then, several studies reported that circRNAs are differentially expressed across tissue types and developmental stages, implying that they are actively regulated and not merely a by-product of splicing. Though functional studies have shown that some circRNAs could act as miRNA-sponges, the function of most circRNAs remains unknown. To expand our understanding of possible roles of circular RNAs, we propose a new pipeline that could fully characterizes candidate circRNA structure from RNAseq data—FUCHS: FUll CHaracterization of circular RNA using RNA-Sequencing. Currently, most computational prediction pipelines use back-spliced reads to identify circular RNAs. FUCHS extends this concept by considering all RNA-seq information from long reads (typically >150 bp to learn more about the exon coverage, the number of double break point fragments, the different circular isoforms arising from one host-gene, and the alternatively spliced exons within the same circRNA boundaries. This new knowledge will enable the user to carry out differential motif enrichment and miRNA seed analysis to determine potential regulators during circRNA biogenesis. FUCHS is an easy-to-use Python based pipeline that contributes a new aspect to the circRNA research.

  11. Analyzing the Gamma-Ray Sky with Wavelets

    Energy Technology Data Exchange (ETDEWEB)

    Balaji, Bhaskaran [Johns Hopkins U.; Cholis, Ilias [Johns Hopkins U.; Fox, Patrick J. [Fermilab; McDermott, Samuel D. [Fermilab

    2018-03-05

    We analyze the gamma-ray sky at energies of 0.5 to 50 GeV using the undecimated wavelet transform on the sphere. Focusing on the inner $60^{\\circ} \\times 60^{\\circ}$ of the sky, we identify and characterize four separate residuals beyond the expected Milky Way diffuse emission. We detect the \\textit{Fermi} Bubbles, finding compelling evidence that they are diffuse in nature and contain very little small-scale structure. We detect the "cocoon" inside the Southern Bubble, and we also identify its northern counterpart above 2 GeV. The Northern Cocoon lies along the same axis but is $\\sim 30 \\%$ dimmer than the southern one. We characterize the Galactic center excess, which we find extends up to $20^{\\circ}$ in $|b|$. At latitudes $|b| \\leq 5^{\\circ}$ we find evidence for power in small angular scales that could be the result of point-source contributions, but for $|b| \\geq 5^{\\circ}$ the Galactic center excess is dominantly diffuse in its nature. Our findings show that either the Galactic center excess and {\\it Fermi} Bubbles connect smoothly or that the Bubbles brighten significantly below $15^\\circ$ in latitude. We find that the Galactic center excess appears off-center by a few degrees towards negative $\\ell$. Additionally, we find and characterize two emissions along the Galactic disk centered at $\\ell \\simeq +25^{\\circ}$ and $-20^{\\circ}$. These emissions are significantly more elongated along the Galactic disk than the Galactic center excess.

  12. Altered expression pattern of circular RNAs in primary and metastatic sites of epithelial ovarian carcinoma.

    Science.gov (United States)

    Ahmed, Ikhlak; Karedath, Thasni; Andrews, Simeon S; Al-Azwani, Iman K; Mohamoud, Yasmin Ali; Querleu, Denis; Rafii, Arash; Malek, Joel A

    2016-06-14

    Recently, a class of endogenous species of RNA called circular RNA (circRNA) has been shown to regulate gene expression in mammals and their role in cellular function is just beginning to be understood. To investigate the role of circRNAs in ovarian cancer, we performed paired-end RNA sequencing of primary sites, peritoneal and lymph node metastases from three patients with stage IIIC ovarian cancer. We developed an in-house computational pipeline to identify and characterize the circRNA expression from paired-end RNA-Seq libraries. This pipeline revealed thousands of circular isoforms in Epithelial Ovarian Carcinoma (EOC). These circRNAs are enriched for potentially effective miRNA seed matches. A significantly larger number of circRNAs are differentially expressed between tumor sites than mRNAs. Circular and linear expression exhibits an inverse trend for many cancer related pathways and signaling pathways like NFkB, PI3k/AKT and TGF-β typically activated for mRNA in metastases are inhibited for circRNA expression. Further, circRNAs show a more robust expression pattern across patients than mRNA forms indicating their suitability as biomarkers in highly heterogeneous cancer transcriptomes. The consistency of circular RNA expression may offer new candidates for cancer treatment and prognosis.

  13. Triple differential cross-sections of Ne (2s2) in coplanar to perpendicular plane geometry

    Science.gov (United States)

    Chen, L. Q.; Khajuria, Y.; Chen, X. J.; Xu, K. Z.

    2003-10-01

    The distorted wave Born approximation (DWBA) with the spin averaged static exchange potential has been used to calculate the triple differential cross-sections (TDCSs) for Ne (2s^2) ionization by electron impact in coplanar to perpendicular plane symmetric geometry at 110.5 eV incident electron energy. The present theoretical results at gun angles Psi = 0^circ (coplanar symmetric geometry) and Psi = 90^circ (perpendicular plane geometry) are in satisfactory agreement with the available experimental data. A deep interference minimum appears in the TDCS in the coplanar symmetric geometry and a strong peak at scattering angle xi = 90^circ caused by the single collision mechanism has been observed in the perpendicular plane geometry. The TDCSs at the gun angles Psi = 30^circ, and Psi = 60^circ are predicted.

  14. The Stage of Imagination: Visual Devices in the "Circe" Episode of James Joyce's Ulysses

    National Research Council Canada - National Science Library

    Benn, Elizabeth

    2002-01-01

    ... and undercurrents of thought and memory. Employing Deleuze's discussion of the captured time image as a moment of possibility and consideration, I argue that the new realm of the subconscious is designed and expressed in a theatric style...

  15. Compact Design of an Electrically Tunable and Rotatable Polarizer Based on a Liquid Crystal Photonic Bandgap Fiber

    DEFF Research Database (Denmark)

    Wei, Lei; Alkeskjold, Thomas Tanggaard; Bjarklev, Anders Overgaard

    2009-01-01

    In this letter, a compact electrically controlled broadband liquid crystal (LC) photonic bandgap fiber polarizer is designed and fabricated. A good fiber coupling quality between two single-mode fibers and one 10-mm-long LC-filled photonic crystal fiber is obtained and protected by using SU-8 fiber...... fixing structures during the device assembly. The total insertion loss of this all-in-fiber device is 2.7 dB. An electrically tunable polarization extinction ratio of 21.3 dB is achieved with 45$^{circ}$ rotatable transmission axis as well as switched on and off in the wavelength range of 1300–1600 nm....

  16. Measurement of the CKM angle $\\gamma$ from a combination of $B^{\\pm} \\to Dh^{\\pm}$ analyses

    CERN Document Server

    INSPIRE-00258707; Abellan Beteta, C; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicheur, A; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; Mc Skelly, B; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rama, M; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, N A; Smith, E; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Sun, L; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-01-01

    A combination of three LHCb measurements of the CKM angle $\\gamma$ is presented. The decays $B^\\pm\\to DK^\\pm$ and $B^\\pm\\to D\\pi^\\pm$ are used, where $D$ denotes an admixture of $D^0$ and $\\overline{D^0}$ mesons, decaying into $K^+K^-$, $\\pi^+\\pi^-$, $K^\\pm \\pi^\\mp$, $K^\\pm \\pi^\\mp \\pi^\\pm \\pi^\\mp$, $K_S\\pi^+\\pi^-$, or $K_S K^+K^-$ final states. All measurements use a dataset corresponding to 1.0 fb$^{-1}$ of data. Combining results from $B^\\pm\\to DK^\\pm$ decays alone a best-fit value of $\\gamma = 72.0^\\circ$ is found, and confidence intervals are set \\begin{align*} \\gamma \\in [56.4,86.7]^\\circ \\quad &{\\rm at\\ 68\\%\\,CL}\\,,\\\\ \\gamma \\in [42.6,99.6]^\\circ \\quad &{\\rm at\\ 95\\%\\,CL}\\,. \\end{align*} The best-fit value of $\\gamma$ found from a combination of results from $B^\\pm\\to D\\pi^\\pm$ decays alone, is $\\gamma = 18.9^\\circ$, and the confidence intervals \\begin{align*} \\gamma \\in [7.4,99.2]^\\circ \\quad \\cup \\quad [167.9,176.4]^\\circ \\quad &{\\rm at\\ 68\\%\\,CL}\\, \\end{align*} are set, without constrai...

  17. A determination of the CP violation parameter $\\eta_{+-}$ from the decay of strangeness-tagged neutral kaons

    CERN Document Server

    Apostolakis, Alcibiades J; Backenstoss, Gerhard; Bargassa, P; Behnke, O; Benelli, A; Bertin, V; Blanc, F; Bloch, P; Carlson, P J; Carroll, M; Cawley, E; Chertok, M B; Danielsson, M; Dejardin, M; Derré, J; Ealet, A; Eleftheriadis, C; Fetscher, W; Fidecaro, Maria; Filipcic, A; Francis, D; Fry, J; Gabathuler, Erwin; Gamet, R; Gerber, H J; Go, A; Haselden, A; Hayman, P J; Henry-Coüannier, F; Hollander, R W; Jon-And, K; Kettle, P R; Kokkas, P; Kreuger, R; Le Gac, R; Leimgruber, F; Mandic, I; Manthos, N; Marel, Gérard; Mikuz, M; Miller, J; Montanet, François; Müller, A; Nakada, Tatsuya; Pagels, B; Papadopoulos, I M; Pavlopoulos, P; Polivka, G; Rickenbach, R; Roberts, B L; Ruf, T; Sakelliou, L; Schäfer, M; Schaller, L A; Schietinger, T; Schopper, A; Tauscher, Ludwig; Thibault, C; Touchard, F; Touramanis, C; van Eijk, C W E; Vlachos, S; Weber, P; Wigger, O; Wolter, M; Yéche, C; Zavrtanik, D; Zimmerman, D

    1999-01-01

    We report a measurement of the CP violation parameter $\\eta$ from the time-dependent asymmetry between the decay rates of initially tagged \\kn\\ and \\knb . The results are based on the complete data sample collected by the CPLEAR collaboration. With $\\dm = (530.1 \\pm 1.4) \\times 10^{7}\\hbar s^{-1}$ and $\\ts = (89.32 \\pm 0.08)$ ps, the values obtained are $\\mita = (2.264 \\pm 0.023_\\mathrm{{stat}} \\pm 0.026_\\mathrm{{syst}} \\pm 0.007_{\\ts}) \\times 10^{-3}$ and $\\fas = 43.19^{\\circ} \\pm 0.53^{\\circ}_\\mathrm{{st at}} \\pm 0.28^{\\circ}_\\mathrm{{syst}} \\pm 0.42^{\\circ}_{\\dm}$.

  18. Detection and Analysis of Circular RNAs by RT-PCR.

    Science.gov (United States)

    Panda, Amaresh C; Gorospe, Myriam

    2018-03-20

    Gene expression in eukaryotic cells is tightly regulated at the transcriptional and posttranscriptional levels. Posttranscriptional processes, including pre-mRNA splicing, mRNA export, mRNA turnover, and mRNA translation, are controlled by RNA-binding proteins (RBPs) and noncoding (nc)RNAs. The vast family of ncRNAs comprises diverse regulatory RNAs, such as microRNAs and long noncoding (lnc)RNAs, but also the poorly explored class of circular (circ)RNAs. Although first discovered more than three decades ago by electron microscopy, only the advent of high-throughput RNA-sequencing (RNA-seq) and the development of innovative bioinformatic pipelines have begun to allow the systematic identification of circRNAs (Szabo and Salzman, 2016; Panda et al ., 2017b; Panda et al ., 2017c). However, the validation of true circRNAs identified by RNA sequencing requires other molecular biology techniques including reverse transcription (RT) followed by conventional or quantitative (q) polymerase chain reaction (PCR), and Northern blot analysis (Jeck and Sharpless, 2014). RT-qPCR analysis of circular RNAs using divergent primers has been widely used for the detection, validation, and sometimes quantification of circRNAs (Abdelmohsen et al ., 2015 and 2017; Panda et al ., 2017b). As detailed here, divergent primers designed to span the circRNA backsplice junction sequence can specifically amplify the circRNAs and not the counterpart linear RNA. In sum, RT-PCR analysis using divergent primers allows direct detection and quantification of circRNAs.

  19. Update of the LHCb combination of the CKM angle $\\gamma$

    CERN Document Server

    Kenzie, Matthew William; The LHCb Collaboration

    2018-01-01

    A combination of tree-level measurements of the CKM angle $\\gamma$ at LHCb is performed. The results are obtained from time-integrated measurements of $B^{+}\\to D K^{+}$, $B^{+}\\to D^{*}K^{+}$, $B^{+}\\to DK^{*+}$, $B^{0}\\to D K^{*0}$, $B^{0}\\to D K^{+}\\pi^{-}$ and $B^{+}\\to DK^{+}\\pi^{+}\\pi^{-}$ decays and time-dependent analyses of $B_{s}^{0}\\to D_{s}^{\\mp}K^{\\pm}$ and $B^{0}\\to D^{\\mp}\\pi^{\\pm}$ decays. This combination includes new and updated results compared to the previous LHCb combination, giving a best fit value of $\\gamma = 74.0^\\circ$ with confidence intervals, set using a frequentist procedure, of $\\gamma \\in [68.2,79.0]^\\circ$ at 68.3 % confidence level (CL) and $\\gamma \\in [61.6,83.7]^\\circ$ at 95.5 % CL, where all values are modulo $180^\\circ$. This gives the result \\begin{align*} \\gamma = (74.0^{+5.0}_{-5.8})^\\circ\\,, \\end{align*} where the uncertainty includes both statistical and systematic contributions.

  20. Silica-induced initiation of circular ZC3H4 RNA/ZC3H4 pathway promotes the pulmonary macrophage activation.

    Science.gov (United States)

    Yang, Xiyue; Wang, Jing; Zhou, Zewei; Jiang, Rong; Huang, Jie; Chen, Lulu; Cao, Zhouli; Chu, Han; Han, Bing; Cheng, Yusi; Chao, Jie

    2018-01-22

    Phagocytosis of silicon dioxide (SiO 2 ) into lung cells causes an inflammatory cascade that results in fibroblast proliferation and migration, followed by fibrosis. Circular RNAs (circRNAs) are a subclass of noncoding RNAs that are present within mammalian cells; however, researchers have not determined whether circRNAs are involved in the pathophysiologic process of silicosis. To elucidate the role of these RNAs in SiO 2 -induced inflammation in pulmonary macrophages, we investigated the upstream molecular mechanisms and functional effects of circRNAs on cell apoptosis, proliferation, and migration. Primary cultures of alveolar macrophages from healthy donors and from patients and the RAW264.7 macrophage cell line were used to explore the functions of circZC3H4 RNA in macrophage activation. The experimental results indicated the following: 1) SiO 2 concomitantly increased circZC3H4 RNA expression and increased ZC3H4 protein levels; 2) circular ZC3H4 (circZC3H4) RNA and ZC3H4 protein participated in SiO 2 -induced macrophage activation; and 3) SiO 2 -activated macrophages promoted fibroblast proliferation and migration via the circZC3H4 RNA/ZC3H4 pathway. The up-regulation of the ZC3H4 protein was confirmed in tissue samples from patients with silicosis. Our study elucidates a link between SiO 2 -induced macrophage activation and the circZC3H4 RNA/ZC3H4 pathway, thereby providing novel insight into the potential use of ZC3H4 to develop novel therapeutic strategies for silicosis.-Yang, X., Wang, J., Zhou, Z., Jiang, R., Huang, J., Chen, L., Cao, Z., Chu, H., Han, B., Cheng, Y., Chao, J. Silica-induced initiation of circular ZC3H4 RNA/ZC3H4 pathway promotes the pulmonary macrophage activation.

  1. In-flight radiation measurements aboard French airliners

    International Nuclear Information System (INIS)

    Montagne, C.; Donne, J.P.; Pelcot, D.; Nguyen, V.D.; Bouisset, P.; Kerlau, G.

    1993-01-01

    Routine radiation monitoring has been carried out for more than 15 years aboard Air France airliners. Annual dose received by aircrews can be estimated in the 2-3 mSv range for subsonic long-haul aircrews. Recent dosimetric measurements, using CIRCE devices based on low-pressure TEPC microdosimetry techniques and by using new types of bubble damage detectors, seem to confirm partly these results. More investigations by these new techniques could be undertaken at other phases of the 11 year solar cycle. (author)

  2. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  3. A Meta-Analysis of the Diagnostic Accuracy of Circular RNAs in Digestive System Malignancy.

    Science.gov (United States)

    Chen, Zhiqiang; Zhang, Long; Han, Guoyong; Zuo, Xueliang; Zhang, Yao; Zhu, Qin; Wu, Jindao; Wang, Xuehao

    2018-01-01

    Circular RNAs (circRNAs), a novel class of noncoding RNAs, have been found to be dysregulated in various cancers. However, the clinical application value of these circRNAs in digestive system cancers remains to be clarified. We aimed to comprehensively explore the potential role of circRNAs as diagnostic indicators in digestive system malignancies. Relevant studies were systematically retrieved from PubMed, Web of Science and the Cochrane Library. The data that were required to complete 2 × 2 contingency tables were obtained from the included studies. Stratified analyses by cancer type, sample size and publication year were performed. Thirteen studies with 2,276 individuals were included in the meta-analysis. The pooled sensitivity and specificity of circRNAs in the diagnosis of digestive system malignancy were 0.72 [95% confidence interval (CI): 0.65-0.77] and 0.77 (95% CI: 0.72-0.81), respectively. The overall positive likelihood ratio was 3.09 (95% CI: 2.64-3.62), and the overall negative likelihood ratio was 0.37 (95% CI: 0.31-0.44). The pooled diagnostic odds ratio was 8.38 (95% CI: 6.86-10.25), and the overall area under the curve was 0.81 (95% CI: 0.77-0.84), indicating good discriminative ability of circRNAs as biomarkers for digestive system malignancy. circRNAs distinguish patients with digestive system cancer from controls with relatively high diagnostic accuracy. circRNAs may be used as potential biomarkers for the diagnosis of digestive system malignancy. © 2018 The Author(s). Published by S. Karger AG, Basel.

  4. Device-Centric Monitoring for Mobile Device Management

    Directory of Open Access Journals (Sweden)

    Luke Chircop

    2016-03-01

    Full Text Available The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centric properties (e.g. the user may not send more than 100 messages per day across all applications being difficult or impossible to verify. In this paper we present a device-centric approach to runtime verify the device behaviour against a device policy with the different applications acting as independent components contributing to the overall behaviour of the device. We also present an implementation for Android devices, and evaluate it on a number of device-centric policies, reporting the empirical results obtained.

  5. Power source device for thermonuclear device

    International Nuclear Information System (INIS)

    Ozaki, Akira.

    1992-01-01

    The present invention provides a small sized and economical power source device for a thermonuclear device. That is, the device comprises a conversion device having a rated power determined by a power required during a plasma current excitation period and a conversion device having a rated power determined by a power required during a plasma current maintaining period, connected in series to each other. Then, for the former conversion device, power is supplied from an electric power generator and, for the latter, power is supplied from a power system. With such a constitution, during the plasma electric current maintaining period for substantially continuous operation, it is possible to conduct bypassing paired operation for the former conversion device while the electric power generator is put under no load. Further, since a short period rated power may be suffice for the former conversion device and the electric power generator having the great rated power required for the plasma electric current excitation period, they can be reduced in the size and made economical. On the other hand, since the power required for the plasma current maintaining period is relatively small, the capacity of the continuous rated conversion device may be small, and the power can be received from the power system. (I.S.)

  6. An economic and environmental analysis of biomass-solar hybrid system for the textile industry in India

    OpenAIRE

    MAHADEVAN, MAHALAKSHMI; SALAI, LATHA

    2015-01-01

    This paper focuses on the design and analysis of a hybrid biomass-solar photovoltaic system for the textile industry with the goal of minimizing the cost and greenhouse gas emissions. The feasibility analysis of the hybrid system is performed based on the resource availability and the power generation potential of the existing biomass power plant near the textile plant at T.Kallupatti in Tamil Nadu, India. The power plant located at the site (9.66$^{\\circ}$N, 77.79$^{\\circ}$E) has an averag...

  7. Iron zircon pigment synthesis: Proposal of a mixing index for the raw materials mixtures; Síntesis del pigmento de hierro-circón: Propuesta de un índice de mezclado para mezclas de materias primas

    Energy Technology Data Exchange (ETDEWEB)

    Zumaquero, E.; Ortsb, M.J.; Sanz, V.; Mestre, S.

    2017-11-01

    Iron zircon coral pigments are very interesting from an industrial point of view because of their high colouring power and their stability at high temperatures. However, the pigment's synthesis is particularly troublesome due to its specific reaction mechanism. As an encapsulated pigment it becomes very important how the raw materials are distributed in the reaction mixture. To evaluate the effectiveness of the mixing process, it would be convenient to define a parameter, that is the mixing index, to estimate the degree of homogeneity of the system. In the current investigation, a mixing index is proposed derived from the power spectrum of Fourier transform of scanning electron microscope (SEM) images of the raw material mixture. Concretely, the number of pixels in a certain range of values in the image of the power spectrum, seems to behave relatively well as mixing index. This index allows us to distinguish between samples with different zirconia and iron oxide used as precursors. The proposed mixing index seems to be related to the colouring power of the final pigment when the synthesis generates enough zircon to encapsulate hematite particles. [Spanish] Los pigmentos coral de hierro-circón son muy interesantes desde el punto de vista industrial ya que n un alto poder colorante y estabilidad a altas temperaturas. Sin embargo, la síntesis del pigmento es particularmente problemática debido a su mecanismo de reacción. Al tratarse de un pigmento encapsulado, resulta fundamental cómo se encuentran distribuidas las materias primas en la mezcla de reacción. Para evaluar la efectividad del proceso de mezclado, es conveniente definir un parámetro, que es el índice de mezclado, para estimar el grado de homogeneidad del sistema. En el presente trabajo de investigación se propone un índice de mezclado basado en el espectro de potencia de la transformada de Fourier de imágenes obtenidas con el microscopio electrónico de barrido de las mezclas de materias

  8. Device-Centric Monitoring for Mobile Device Management

    OpenAIRE

    Chircop, Luke; Colombo, Christian; Pace, Gordon J.

    2016-01-01

    The ubiquity of computing devices has led to an increased need to ensure not only that the applications deployed on them are correct with respect to their specifications, but also that the devices are used in an appropriate manner, especially in situations where the device is provided by a party other than the actual user. Much work which has been done on runtime verification for mobile devices and operating systems is mostly application-centric, resulting in global, device-centri...

  9. A time series study on the effects of heat on mortality and evaluation of heterogeneity into European and Eastern-Southern Mediterranean cities: results of EU CIRCE project.

    Science.gov (United States)

    Leone, Michela; D'Ippoliti, Daniela; De Sario, Manuela; Analitis, Antonis; Menne, Bettina; Katsouyanni, Klea; De' Donato, Francesca K; Basagana, Xavier; Salah, Afif Ben; Casimiro, Elsa; Dörtbudak, Zeynep; Iñiguez, Carmen; Peretz, Chava; Wolf, Tanja; Michelozzi, Paola

    2013-07-03

    The Mediterranean region is particularly vulnerable to the effect of summer temperature.Within the CIRCE project this time-series study aims to quantify for the first time the effect of summer temperature in Eastern-Southern Mediterranean cities and compared it with European cities around the Mediterranean basin, evaluating city characteristics that explain between-city heterogeneity. The city-specific effect of maximum apparent temperature (Tappmax) was assessed by Generalized Estimation Equations, assuming a linear threshold model. Then, city-specific estimates were included in a random effect meta-regression analysis to investigate the effect modification by several city characteristics. Heterogeneity in the temperature-mortality relationship was observed among cities. Thresholds recorded higher values in the warmest cities of Tunis (35.5°C) and Tel-Aviv (32.8°C) while the effect of Tappmax above threshold was greater in the European cities. In Eastern-Southern Mediterranean cities a higher effect was observed among younger age groups (0-14 in Tunis and 15-64 in Tel-Aviv and Istanbul) in contrast with the European cities where the elderly population was more vulnerable. Climate conditions explained most of the observed heterogeneity and among socio-demographic and economic characteristics only health expenditure and unemployment rate were identified as effect modifiers. The high vulnerability observed in the young populations in Eastern-Southern Mediterranean cities represent a major public health problem. Considering the large political and economic changes occurring in this region as well future temperature increase due to climate change, it is important to strengthen research and public health efforts in these Mediterranean countries.

  10. Ontology-Based Device Descriptions and Device Repository for Building Automation Devices

    Directory of Open Access Journals (Sweden)

    Dibowski Henrik

    2011-01-01

    Full Text Available Device descriptions play an important role in the design and commissioning of modern building automation systems and help reducing the design time and costs. However, all established device descriptions are specialized for certain purposes and suffer from several weaknesses. This hinders a further design automation, which is strongly needed for the more and more complex building automation systems. To overcome these problems, this paper presents novel Ontology-based Device Descriptions (ODDs along with a layered ontology architecture, a specific ontology view approach with virtual properties, a generic access interface, a triple store-based database backend, and a generic search mask GUI with underlying query generation algorithm. It enables a formal, unified, and extensible specification of building automation devices, ensures their comparability, and facilitates a computer-enabled retrieval, selection, and interoperability evaluation, which is essential for an automated design. The scalability of the approach to several ten thousand devices is demonstrated.

  11. Multi-Device to Multi-Device (MD2MD Content-Centric Networking Based on Multi-RAT Device

    Directory of Open Access Journals (Sweden)

    Cheolhoon Kim

    2017-11-01

    Full Text Available This paper proposes a method whereby a device can transmit and receive information using a beacon, and also describes application scenarios for the proposed method. In a multi-device to multi-device (MD2MD content-centric networking (CCN environment, the main issue involves searching for and connecting to nearby devices. However, if a device can’t find another device that satisfies its requirements, the connection is delayed due to the repetition of processes. It is possible to rapidly connect to a device without repetition through the selection of the optimal device using the proposed method. Consequently, the proposed method and scenarios are advantageous in that they enable efficient content identification and delivery in a content-centric Internet of Things (IoT environment, in which multiple mobile devices coexist.

  12. Slope Estimation from ICESat/GLAS

    Directory of Open Access Journals (Sweden)

    Craig Mahoney

    2014-10-01

    Full Text Available We present a novel technique to infer ground slope angle from waveform LiDAR, known as the independent slope method (ISM. The technique is applied to large footprint waveforms (\\(\\sim\\ mean diameter from the Ice, Cloud and Land Elevation Satellite (ICESat Geoscience Laser Altimeter System (GLAS to produce a slope dataset of near-global coverage at \\(0.5^{\\circ} \\times 0.5^{\\circ}\\ resolution. ISM slope estimates are compared against high resolution airborne LiDAR slope measurements for nine sites across three continents. ISM slope estimates compare better with the aircraft data (R\\(^{2}=0.87\\ and RMSE\\(=5.16^{\\circ}\\ than the Shuttle Radar Topography Mission Digital Elevation Model (SRTM DEM inferred slopes (R\\(^{2}=0.71\\ and RMSE\\(=8.69^{\\circ}\\ ISM slope estimates are concurrent with GLAS waveforms and can be used to correct biophysical parameters, such as tree height and biomass. They can also be fused with other DEMs, such as SRTM, to improve slope estimates.

  13. Hyperfine interactions in MnAs studied by perturbed angular correlations of $\\gamma$-rays using the probe $^{77}$Br $\\rightarrow ^{77}$Se and first principles calculations for MnAs and other Mn pnictides

    CERN Document Server

    Gonçalves, J N; Correia, J G; Lopes, A M L

    2011-01-01

    The MnAs compound shows a first-order transition at T$_{c}$≈ 42$^{\\circ}$C, and a second-order transition at T$_{t}$ ≈120$^{\\circ}$C. The first-order transition, with structural (hexagonal-orthorhombic), magnetic (FM-PM) and electrical conductivity changes, is associated to magnetocaloric, magnetoelastic, and magnetoresistance effects. We report a study in a large temperature range from −196$^{\\circ}$C up to 140$^{\\circ}$C, using the $\\gamma\\!-\\!\\gamma$ perturbed angular correlations method with the radioactive probe $^{77}$Br→$^{77}$Se, produced at the ISOLDE-CERN facility. The electric field gradients and magnetic hyperfine fields are determined across the first- and second-order phase transitions encompassing the pure and mixed phase regimes in cooling and heating cycles. The temperature irreversibility of the 1st order phase transition is seen locally, at the nanoscopic scale sensitivity of the hyperfine field, by its hysteresis, detailing and complementing information obtained with macroscopic me...

  14. Graphene device and method of using graphene device

    Science.gov (United States)

    Bouchiat, Vincent; Girit, Caglar; Kessler, Brian; Zettl, Alexander K.

    2015-08-11

    An embodiment of a graphene device includes a layered structure, first and second electrodes, and a dopant island. The layered structure includes a conductive layer, an insulating layer, and a graphene layer. The electrodes are coupled to the graphene layer. The dopant island is coupled to an exposed surface of the graphene layer between the electrodes. An embodiment of a method of using a graphene device includes providing the graphene device. A voltage is applied to the conductive layer of the graphene device. Another embodiment of a method of using a graphene device includes providing the graphene device without the dopant island. A dopant island is placed on an exposed surface of the graphene layer between the electrodes. A voltage is applied to the conductive layer of the graphene device. A response of the dopant island to the voltage is observed.

  15. Humanitarian Use Devices/Humanitarian Device Exemptions in cardiovascular medicine.

    Science.gov (United States)

    Kaplan, Aaron V; Harvey, Elisa D; Kuntz, Richard E; Shiran, Hadas; Robb, John F; Fitzgerald, Peter

    2005-11-01

    The Second Dartmouth Device Development Symposium held in October 2004 brought together leaders from the medical device community, including clinical investigators, senior representatives from the US Food and Drug Administration, large and small device manufacturers, and representatives from the financial community to examine difficult issues confronting device development. The role of the Humanitarian Use Device/Humanitarian Device Exemption (HUD/HDE) pathway in the development of new cardiovascular devices was discussed in this forum. The HUD/HDE pathway was created by Congress to facilitate the availability of medical devices for "orphan" indications, ie, those affecting HDEs have been granted (23 devices, 6 diagnostic tests). As the costs to gain regulatory approval for commonly used devices increase, companies often seek alternative ways to gain market access, including the HUD/HDE pathway. For a given device, there may be multiple legitimate and distinct indications, including indications that meet the HUD criteria. Companies must choose how and when to pursue each of these indications. The consensus of symposium participants was for the HUD/HDE pathway to be reserved for true orphan indications and not be viewed strategically as part of the clinical development plan to access a large market.

  16. DeviceNet-based device-level control in SSRF

    CERN Document Server

    Leng Yong Bin; Lu Cheng Meng; Miao Hai Feng; Liu Song Qiang; Shen Guo Bao

    2002-01-01

    The control system of Shanghai Synchrotron Radiation Facility is an EPICS-based distributed system. One of the key techniques to construct the system is the device-level control. The author describes the design and implementation of the DeviceNet-based device controller. A prototype of the device controller was tested in the experiments of magnet power supply and the result showed a precision of 3 x 10 sup - sup 5

  17. Numerical and Experimental Studies of Transient Natural Convection with Density Inversion

    Science.gov (United States)

    Mizutani, Satoru; Ishiguro, Tatsuji; Kuwahara, Kunio

    1996-11-01

    In beer manufacturing process, we cool beer in storage tank down from 8 to -1 ^circC. The understanding of cooling process is very important for designing a fermentation tank. In this paper, flow and temperature distribution in a rectangular enclosure was studied. The unsteady incompressible Navier-Stokes equations were integrated by using the multi-directional third-order upwind finite difference method(MUFDM). A parabolic density-temperature relationship was assumed in water which has the maximum density at 3.98 ^circC. Cooling down from 8 to 0 ^circC of water in 10 cm cubical enclosure (Ra=10^7) was numerically done by keeping a vertical side wall at 0 ^circC. Vortex was caused by density inversion of water which was cooled bellow 4 ^circC, and it rose near the cold wall and reached water surface after 33 min from the start of cooling. Finally, cooling proceeded from upper surface. At the aim of verifing the accuracy of the numerical result, temperature distribution under the same condition was experimentally visualized using temperature sensitive liquid crystal. The results will be presented by using video movie. Comparison between the computation and the experiment showed that the present direct simulation based on the MUFDM was powerful tool for the understanding of the natural convection with density inversion and the application of cooling phenomenon to the design of beer storage tanks.

  18. QoE-Aware Device-to-Device Multimedia Communications

    Directory of Open Access Journals (Sweden)

    Liang ZHOU

    2015-08-01

    Full Text Available Multimedia services over mobile device-to-device (D2D networks has recently received considerable attention. In this scenario, each device is equipped with a cellular communication interface, as well as a D2D interface over a shared medium. In this work, we study the performance properties of the mobile D2D communications in the framework of user satisfaction, and develop a fully distributed QoE-aware multimedia communication scheme (QAMCS. Specifically, we translate the opportunistic multimedia communications issue into a stochastic optimization problem, which opens up a new degree of performance to exploit. Moreover, QAMCS is designed for a heterogeneous and dynamic environment, in which user demand, device mobility, and transmission fashion may vary across different devices and applications. Importantly, QAMCS is able to maximize the user satisfaction and only needs each device to implement its own scheme individually in the absence of a central controller.

  19. Virtual MIMO Beamforming and Device Pairing Enabled by Device-to-Device Communications for Multidevice Networks

    Directory of Open Access Journals (Sweden)

    Yeonjin Jeong

    2017-01-01

    Full Text Available We consider a multidevice network with asymmetric antenna configurations which supports not only communications between an access point and devices but also device-to-device (D2D communications for the Internet of things. For the network, we propose the transmit and receive beamforming with the channel state information (CSI for virtual multiple-input multiple-output (MIMO enabled by D2D receive cooperation. We analyze the sum rate achieved by a device pair in the proposed method and identify the strategies to improve the sum rate of the device pair. We next present a distributed algorithm and its equivalent algorithm for device pairing to maximize the throughput of the multidevice network. Simulation results confirm the advantages of the transmit CSI and D2D cooperation as well as the validity of the distributive algorithm.

  20. The Climate Impacts Research Consortium: Lessons Learned from the Evaluation of Co-production projects

    Science.gov (United States)

    Sokolovska, I.; Andrepont, J. A.; Lach, D.

    2017-12-01

    The Pacific Northwest Climate Impacts Research Consortium (CIRC) is a climate-science-to-climate-action team funded by the National Oceanic and Atmospheric Administration (NOAA), member of NOAA's Regional Integrated Sciences and Assessments (RISA) program. The internal evaluation of the last 6 years of CIRC's work focused on the co-production of knowledge process. The evaluation was based on CIRC's Reflection and Logic model and used a mixed methods design. During regular monthly meetings in 2014/15, all CIRC PIs reflected on the co-production process and presented their evaluation of the projects they worked on. Additionally, we conducted semi-structured interviews with CIRC participants, purposefully targeting key informants. The Climate Impacts Research Consortium teams also administered surveys to assess participants' experiences of the coproduction process as they were engaging in it. Identifying and cultivating an informant from the local stakeholder group with deep, accessible roots within the target community can lead to better coproduction results than having to build those relationships from naught. Across projects, most participants agreed that the project increased their understanding of their area's hazards and by the end of the project most participants were confident the project would produce useful results for themselves. Finally, most participants intended to share what they had learned from this experience with their colleagues and we found that co-production built capacities necessary for communities to incorporate climate change in discussions even after the end of CIRC's participation. During the projects, the involvement of non-traditional participants along with experts was critical to success and a lot of work and preparation needs to be put into the planning of any co-production meeting to overcome various barriers to communication and build trust.

  1. Release strategies for making transferable semiconductor structures, devices and device components

    Science.gov (United States)

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  2. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  3. The structure of the muscle protein complex 4Ca2+ ·troponin C · troponin

    International Nuclear Information System (INIS)

    Olah, G.A.; Trewhella, J.

    1994-01-01

    Analysis of scattering data based on a Monte Carlo integration method was used to 2+ obtain a low resolution model of the 4Ca 2+ circ troponin C circ troponin I complex. This modeling method allows rapid testing of plausible structures where the best fit model can be ascertained by a comparison between model structure scattering profiles and measured scattering data. In the best fit model, troponin I appears as a spiral structure 2+ that wraps around 4Ca 2+ circ troponin C which adopts an extended dumbbell conformation similar to that observed in the crystal structures of troponin C. The Monte Carlo modeling method can be applied to other biological systems in which detailed structural information is lacking

  4. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  5. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  6. Practical microwave electron devices

    CERN Document Server

    Meurant, Gerard

    2013-01-01

    Practical Microwave Electron Devices provides an understanding of microwave electron devices and their applications. All areas of microwave electron devices are covered. These include microwave solid-state devices, including popular microwave transistors and both passive and active diodes; quantum electron devices; thermionic devices (including relativistic thermionic devices); and ferrimagnetic electron devices. The design of each of these devices is discussed as well as their applications, including oscillation, amplification, switching, modulation, demodulation, and parametric interactions.

  7. Results from a combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter

    CERN Document Server

    Ajaltouni, Ziad J; Alifanov, A; Amaral, P; Ambrosini, G; Amorim, A; Anderson, K J; Astvatsaturov, A R; Aubert, Bernard; Augé, E; Autiero, D; Azuelos, Georges; Badaud, F; Baisin, L; Battistoni, G; Bazan, A; Bee, C P; Bellettini, Giorgio; Berglund, S R; Berset, J C; Blaj, C; Blanchot, G; Blucher, E; Bogush, A A; Bohm, C; Boldea, V; Borisov, O N; Bosman, M; Bouhemaid, N; Brette, P; Bromberg, C; Brossard, M; Budagov, Yu A; Buono, S; Calôba, L P; Camin, D V; Canton, B; Casado, M P; Cavalli, D; Cavalli-Sforza, M; Cavasinni, V; Chadelas, R; Chase, Robert L; Chekhtman, A; Chevaleyre, J C; Chevalley, J L; Chirikov-Zorin, I E; Chlachidze, G; Chollet, J C; Cobal, M; Cogswell, F; Colas, Jacques; Collot, J; Cologna, S; Constantinescu, S; Costa, G; Costanzo, D; Cozzi, L; Crouau, M; Dargent, P; Daudon, F; David, M; Davidek, T; Dawson, J; De, K; de La Taille, C; Del Prete, T; Depommier, P; de Saintignon, P; De Santo, A; Dinkespiler, B; Di Girolamo, B; Dita, S; Dolejsi, J; Dolezal, Z; Downing, R; Dugne, J J; Duval, P Y; Dzahini, D; Efthymiopoulos, I; Errede, D; Errede, S; Etienne, F; Evans, H; Fassnacht, P; Fedyakin, N N; Ferrari, A; Ferreira, P; Ferrer, A; Flaminio, Vincenzo; Fouchez, D; Fournier, D; Fumagalli, G; Gallas, E J; Gaspar, M; Gianotti, F; Gildemeister, O; Gingrich, D M; Glagolev, V V; Golubev, V B; Gómez, A; González, J; Gordon, H A; Grabskii, V; Hakopian, H H; Haney, M; Hellman, S; Henriques, A; Holmgren, S O; Honoré, P F; Hostachy, J Y; Huston, J; Ivanyushenkov, Yu M; Jézéquel, S; Johansson, E K; Jon-And, K; Jones, R; Juste, A; Kakurin, S; Karapetian, G V; Karyukhin, A N; Khokhlov, Yu A; Klioukhine, V I; Kolomoets, V; Kopikov, S V; Kostrikov, M E; Kovtun, V E; Kukhtin, V V; Kulagin, M; Kulchitskii, Yu A; Laborie, G; Lami, S; Lapin, V; Lebedev, A; Lefebvre, M; Le Flour, T; Leitner, R; León-Florián, E; Leroy, C; Le Van-Suu, A; Li, J; Liba, I; Linossier, O; Lokajícek, M; Lomakin, Yu F; Lomakina, O V; Lund-Jensen, B; Mahout, G; Maio, A; Malyukov, S N; Mandelli, L; Mansoulié, B; Mapelli, Livio P; Marin, C P; Marroquin, F; Martin, L; Mazzanti, M; Mazzoni, E; Merritt, F S; Michel, B; Miller, R; Minashvili, I A; Miotto, A; Miralles, L; Mnatzakanian, E A; Monnier, E; Montarou, G; Mornacchi, Giuseppe; Muanza, G S; Nagy, E; Némécek, S; Nessi, Marzio; Nicoleau, S; Noppe, J M; Olivetto, C; Orteu, S; Padilla, C; Pallin, D; Pantea, D; Parrour, G; Pereira, A; Perini, L; Perlas, J A; Pétroff, P; Pilcher, J E; Pinfold, James L; Poggioli, Luc; Poirot, S; Polesello, G; Price, L; Protopopov, Yu; Proudfoot, J; Pukhov, O; Radeka, V; Rahm, David Charles; Reinmuth, G; Renardy, J F; Renzoni, G; Resconi, S; Richards, R; Riu, I; Romanov, V; Ronceux, B; Rumyantsev, V; Rusakovitch, N A; Sala, P R; Sanders, H; Sauvage, G; Savard, P; Savoy-Navarro, Aurore; Sawyer, L; Says, L P; Schaffer, A C; Scheel, C V; Schwemling, P; Schindling, J; Seguin-Moreau, N; Seixas, J M; Selldén, B; Seman, M; Semenov, A A; Senchyshyn, V G; Serin, L; Shchelchkov, A S; Shevtsov, V P; Shochet, M J; Sidorov, V; Simaitis, V J; Simion, S; Sissakian, A N; Solodkov, A A; Sonderegger, P; Soustruznik, K; Stanek, R; Starchenko, E A; Stephani, D; Stephens, R; Studenov, S; Suk, M; Surkov, A; Tang, F; Tardell, S; Tas, P; Teiger, J; Teubert, F; Thaler, J J; Tisserant, S; Tokár, S; Topilin, N D; Trka, Z; Turcot, A S; Turcotte, M; Valkár, S; Vartapetian, A H; Vazeille, F; Vichou, I; Vinogradov, V; Vorozhtsov, S B; Vuillemin, V; Wagner, D; White, Alan R; Wingerter-Seez, I; Yamdagni, N; Yarygin, G; Yosef, C; Zaitsev, A; Zdrazil, M; Zitoun, R; Zolnierowski, Y

    1996-01-01

    The first combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 20 to 300~GeV at an incident angle $\\theta$ of about 11$^\\circ$ is well-described by the expression $\\sigma/E = ((46.5 \\pm 6.0)\\%/\\sqrt{E} +(1.2 \\pm 0.3)\\%) \\oplus (3.2 \\pm 0.4)~\\mbox{GeV}/E$. Shower profiles, shower leakage, and the angular resolution of hadronic showers were also studied.

  8. The structure of the muscle protein complex 4Ca{sup 2+} {center_dot}troponin C {center_dot} troponin

    Energy Technology Data Exchange (ETDEWEB)

    Olah, G.A.; Trewhella, J. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    Analysis of scattering data based on a Monte Carlo integration method was used to 2+ obtain a low resolution model of the 4Ca{sup 2+}{circ} troponin C{circ}troponin I complex. This modeling method allows rapid testing of plausible structures where the best fit model can be ascertained by a comparison between model structure scattering profiles and measured scattering data. In the best fit model, troponin I appears as a spiral structure 2+ that wraps around 4Ca{sup 2+}{circ}troponin C which adopts an extended dumbbell conformation similar to that observed in the crystal structures of troponin C. The Monte Carlo modeling method can be applied to other biological systems in which detailed structural information is lacking.

  9. Medical Devices; General Hospital and Personal Use Devices; Classification of the Ultraviolet Radiation Chamber Disinfection Device. Final order.

    Science.gov (United States)

    2015-11-20

    The Food and Drug Administration (FDA or the Agency) is classifying the ultraviolet (UV) radiation chamber disinfection device into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the UV radiation chamber disinfection device classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  10. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  11. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  12. High voltage semiconductor devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2018-01-23

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  13. Process control device

    International Nuclear Information System (INIS)

    Hayashi, Toshifumi; Kobayashi, Hiroshi.

    1994-01-01

    A process control device comprises a memory device for memorizing a plant operation target, a plant state or a state of equipments related with each other as control data, a read-only memory device for storing programs, a plant instrumentation control device or other process control devices, an input/output device for performing input/output with an operator, and a processing device which conducts processing in accordance with the program and sends a control demand or a display demand to the input/output device. The program reads out control data relative to a predetermined operation target, compares and verify them with actual values to read out control data to be a practice premise condition which is further to be a practice premise condition if necessary, thereby automatically controlling the plant or requiring or displaying input. Practice presuming conditions for the operation target can be examined succesively in accordance with the program without constituting complicated logical figures and AND/OR graphs. (N.H.)

  14. Natural RNA circles function as efficient microRNA sponges

    DEFF Research Database (Denmark)

    Hansen, Thomas Birkballe; Jensen, Trine I; Clausen, Bettina Hjelm

    2013-01-01

    MicroRNAs (miRNAs) are important post-transcriptional regulators of gene expression that act by direct base pairing to target sites within untranslated regions of messenger RNAs. Recently, miRNA activity has been shown to be affected by the presence of miRNA sponge transcripts, the so-called comp......MicroRNAs (miRNAs) are important post-transcriptional regulators of gene expression that act by direct base pairing to target sites within untranslated regions of messenger RNAs. Recently, miRNA activity has been shown to be affected by the presence of miRNA sponge transcripts, the so......-called competing endogenous RNA in humans and target mimicry in plants. We previously identified a highly expressed circular RNA (circRNA) in human and mouse brain. Here we show that this circRNA acts as a miR-7 sponge; we term this circular transcript ciRS-7 (circular RNA sponge for miR-7). ciRS-7 contains more...... sponge, suggesting that miRNA sponge effects achieved by circRNA formation are a general phenomenon. This study serves as the first, to our knowledge, functional analysis of a naturally expressed circRNA....

  15. A Green Bank Telescope Survey of Large Galactic H II Regions

    Science.gov (United States)

    Anderson, L. D.; Armentrout, W. P.; Luisi, Matteo; Bania, T. M.; Balser, Dana S.; Wenger, Trey V.

    2018-02-01

    As part of our ongoing H II Region Discovery Survey (HRDS), we report the Green Bank Telescope detection of 148 new angularly large Galactic H II regions in radio recombination line (RRL) emission. Our targets are located at a declination of δ > -45^\\circ , which corresponds to 266^\\circ > {\\ell }> -20^\\circ at b=0^\\circ . All sources were selected from the Wide-field Infrared Survey Explorer Catalog of Galactic H II Regions, and have infrared angular diameters ≥slant 260\\prime\\prime . The Galactic distribution of these “large” H II regions is similar to that of the previously known sample of Galactic H II regions. The large H II region RRL line width and peak line intensity distributions are skewed toward lower values, compared with that of previous HRDS surveys. We discover seven sources with extremely narrow RRLs 100 {pc}, making them some of the physically largest known H II regions in the Galaxy. This survey completes the HRDS H II region census in the Northern sky, where we have discovered 887 H II regions and more than doubled the size of the previously known census of Galactic H II regions.

  16. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  17. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  18. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  19. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  20. 21 CFR 864.9195 - Blood mixing devices and blood weighing devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood mixing devices and blood weighing devices. 864.9195 Section 864.9195 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That...

  1. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  2. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  3. Identification of Novel Long Non-coding and Circular RNAs in Human Papillomavirus-Mediated Cervical Cancer

    Directory of Open Access Journals (Sweden)

    Hongbo Wang

    2017-09-01

    Full Text Available Cervical cancer is the third most common cancer worldwide and the fourth leading cause of cancer-associated mortality in women. Accumulating evidence indicates that long non-coding RNAs (lncRNAs and circular RNAs (circRNAs may play key roles in the carcinogenesis of different cancers; however, little is known about the mechanisms of lncRNAs and circRNAs in the progression and metastasis of cervical cancer. In this study, we explored the expression profiles of lncRNAs, circRNAs, miRNAs, and mRNAs in HPV16 (human papillomavirus genotype 16 mediated cervical squamous cell carcinoma and matched adjacent non-tumor (ATN tissues from three patients with high-throughput RNA sequencing (RNA-seq. In total, we identified 19 lncRNAs, 99 circRNAs, 28 miRNAs, and 304 mRNAs that were commonly differentially expressed (DE in different patients. Among the non-coding RNAs, 3 lncRNAs and 44 circRNAs are novel to our knowledge. Functional enrichment analysis showed that DE lncRNAs, miRNAs, and mRNAs were enriched in pathways crucial to cancer as well as other gene ontology (GO terms. Furthermore, the co-expression network and function prediction suggested that all 19 DE lncRNAs could play different roles in the carcinogenesis and development of cervical cancer. The competing endogenous RNA (ceRNA network based on DE coding and non-coding RNAs showed that each miRNA targeted a number of lncRNAs and circRNAs. The link between part of the miRNAs in the network and cervical cancer has been validated in previous studies, and these miRNAs targeted the majority of the novel non-coding RNAs, thus suggesting that these novel non-coding RNAs may be involved in cervical cancer. Taken together, our study shows that DE non-coding RNAs could be further developed as diagnostic and therapeutic biomarkers of cervical cancer. The complex ceRNA network also lays the foundation for future research of the roles of coding and non-coding RNAs in cervical cancer.

  4. Identification of Novel Long Non-coding and Circular RNAs in Human Papillomavirus-Mediated Cervical Cancer

    Science.gov (United States)

    Wang, Hongbo; Zhao, Yingchao; Chen, Mingyue; Cui, Jie

    2017-01-01

    Cervical cancer is the third most common cancer worldwide and the fourth leading cause of cancer-associated mortality in women. Accumulating evidence indicates that long non-coding RNAs (lncRNAs) and circular RNAs (circRNAs) may play key roles in the carcinogenesis of different cancers; however, little is known about the mechanisms of lncRNAs and circRNAs in the progression and metastasis of cervical cancer. In this study, we explored the expression profiles of lncRNAs, circRNAs, miRNAs, and mRNAs in HPV16 (human papillomavirus genotype 16) mediated cervical squamous cell carcinoma and matched adjacent non-tumor (ATN) tissues from three patients with high-throughput RNA sequencing (RNA-seq). In total, we identified 19 lncRNAs, 99 circRNAs, 28 miRNAs, and 304 mRNAs that were commonly differentially expressed (DE) in different patients. Among the non-coding RNAs, 3 lncRNAs and 44 circRNAs are novel to our knowledge. Functional enrichment analysis showed that DE lncRNAs, miRNAs, and mRNAs were enriched in pathways crucial to cancer as well as other gene ontology (GO) terms. Furthermore, the co-expression network and function prediction suggested that all 19 DE lncRNAs could play different roles in the carcinogenesis and development of cervical cancer. The competing endogenous RNA (ceRNA) network based on DE coding and non-coding RNAs showed that each miRNA targeted a number of lncRNAs and circRNAs. The link between part of the miRNAs in the network and cervical cancer has been validated in previous studies, and these miRNAs targeted the majority of the novel non-coding RNAs, thus suggesting that these novel non-coding RNAs may be involved in cervical cancer. Taken together, our study shows that DE non-coding RNAs could be further developed as diagnostic and therapeutic biomarkers of cervical cancer. The complex ceRNA network also lays the foundation for future research of the roles of coding and non-coding RNAs in cervical cancer. PMID:28970820

  5. Radioactive waste processing device

    International Nuclear Information System (INIS)

    Inaguma, Masahiko; Takahara, Nobuaki; Hara, Satomi.

    1996-01-01

    In a processing device for filtering laundry liquid wastes and shower drains incorporated with radioactive materials, a fiber filtration device is disposed and an activated carbon filtration device is also disposed subsequent to the fiber filtration device. In addition, a centrifugal dewatering device is disposed for dewatering spent granular activated carbon in the activated carbon filtration device, and a minute filtering device is disposed for filtering the separated dewatering liquid. Filtrates filtered by the minute filtration device are recovered in a collecting tank. Namely, at first, suspended solid materials in laundry liquid wastes and shower drains are captured, and then, ingredients concerning COD are adsorbed in the activated carbon filtration device. The radioactive liquid wastes of spent granular activated carbon in the activated carbon filtration device are reduced by dewatering them by the centrifugal dewatering device, and then the granular activated carbon is subjected to an additional processing. Further, it is separated by filtration using the minute filtration device and removed as cakes. Since the filtrates are recovered to the collecting tank and filtered again, the water quality of the drains is not degraded. (N.H.)

  6. High heat flux device of thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo.

    1994-01-01

    The present invention provides an equipments for high heat flux device (divertor) of a thermonuclear device, which absorbs thermal deformation during operation, has a high installation accuracy, and sufficiently withstands for thermal stresses. Namely, a heat sink member is joined to a structural base. Armour tiles are joined on the heat sink member. Cooling pipes are disposed between the heat sink member and the armour tiles. With such a constitution, the heat sink member using a highly heat conductive material having ductility, such as oxygen free copper, the cooling pipes using a material having excellent high temperature resistance and excellent elongation, such as aluminum-dispersed reinforced copper, and the armour tiles are completely joined on the structural base. Therefore, when thermal deformation tends to cause in the high heat flux device such as a divertor, cooling pipes cause no plastic deformation because of their high temperature resistance, but the heat sink member such as a oxygen free copper causes plastic deformation to absorb thermal deformation. As a result, the high heat flux device such as a divertor causes no deformation. (I.S.)

  7. Repairing method and device for thermonuclear device

    International Nuclear Information System (INIS)

    Sakurai, Akiko; Masumoto, Hiroshi; Tachikawa, Nobuo.

    1995-01-01

    The present invention provides a method of and a device for repairing a first wall and a divertor disposed in a vacuum vessel of a thermonuclear device. Namely, an armour tile of the divertor secured, by a brazing material, in a vacuum vessel of the thermonuclear device in which high temperature plasmas of deuterium and tritium are confined to cause fusion reaction is induction-heated or heated by microwaves to melt the brazing material. Only the armour tile is thus exchanged by its attachment/detachment. This device comprises, in the vacuum vessel, an armour tile attaching/detaching manipulator and a repairing manipulator comprising a heating manipulator having induction heating coils at the top end thereof. Induction heating coils are connected to an AC power source. According to the present invention, the armour tile is exchanged without taking the divertor out of the vacuum vessel. Therefore, cutting of a divertor cooling tube for taking the divertor out of the vacuum vessel and re-welding of the divertor for attaching it to the vacuum vessel again are no more necessary. (I.S.)

  8. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  9. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  10. Methodological aspects about the use of the radicarbon dating in historical time sites

    OpenAIRE

    Lubritto, Carmine

    2009-01-01

    In this paper basic concepts concerning radiocarbon dating and Accelerator Mass Spectrometry (AMS) technique, and specifically the Centre for Isotopic Research on Cultural and Environmental heritage (CIRCE Laboratory) AMS facility, will be given. Problem of contaminations in radiocarbon AMS measurements will be introduced, and the sample preparation laboratory and the graphitisation lines that are used at the CIRCE Laboratory will be presented. Moreover problems of sampling and interpretation...

  11. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-06-10

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... certain electronic devices, including wireless communication devices, portable music and data processing...

  12. Novel Concepts for Device to Device Communication using Network Coding

    DEFF Research Database (Denmark)

    Pahlevani, Peyman; Hundebøll, Martin; Pedersen, Morten Videbæk

    2014-01-01

    Device-to-device communication is currently a hot research topic within 3GPP. Even though D2D communication has been part of previous ad hoc, meshed and sensor networks proposals, the main contribution by 3GPP is that the direct communication among two devices is carried out over a dynamically as...

  13. Device configuration-management system

    International Nuclear Information System (INIS)

    Nowell, D.M.

    1981-01-01

    The Fusion Chamber System, a major component of the Magnetic Fusion Test Facility, contains several hundred devices which report status to the Supervisory Control and Diagnostic System for control and monitoring purposes. To manage the large number of diversity of devices represented, a device configuration management system was required and developed. Key components of this software tool include the MFTF Data Base; a configuration editor; and a tree structure defining the relationships between the subsystem devices. This paper will describe how the configuration system easily accomodates recognizing new devices, restructuring existing devices, and modifying device profile information

  14. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  15. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  16. Device-independent randomness amplification with a single device

    International Nuclear Information System (INIS)

    Plesch, Martin; Pivoluska, Matej

    2014-01-01

    Expansion and amplification of weak randomness with untrusted quantum devices has recently become a very fruitful topic of research. Here we contribute with a procedure for amplifying a single weak random source using tri-partite GHZ-type entangled states. If the quality of the source reaches a fixed threshold R=log 2 ⁡(10), perfect random bits can be produced. This technique can be used to extract randomness from sources that can't be extracted neither classically, nor by existing procedures developed for Santha–Vazirani sources. Our protocol works with a single fault-free device decomposable into three non-communicating parts, that is repeatedly reused throughout the amplification process. - Highlights: • We propose a protocol for device independent randomness amplification. • Our protocol repeatedly re-uses a single device decomposable into three parts. • Weak random sources with min-entropy rate greater than 1/4 log 2 ⁡(10) can be amplified. • Security against all-quantum adversaries is achieved

  17. Smart portable rehabilitation devices

    Directory of Open Access Journals (Sweden)

    Leahey Matt

    2005-07-01

    Full Text Available Abstract Background The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s. Methods In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Results Laboratory tests of the devices

  18. Smart portable rehabilitation devices.

    Science.gov (United States)

    Mavroidis, Constantinos; Nikitczuk, Jason; Weinberg, Brian; Danaher, Gil; Jensen, Katherine; Pelletier, Philip; Prugnarola, Jennifer; Stuart, Ryan; Arango, Roberto; Leahey, Matt; Pavone, Robert; Provo, Andrew; Yasevac, Dan

    2005-07-12

    The majority of current portable orthotic devices and rehabilitative braces provide stability, apply precise pressure, or help maintain alignment of the joints with out the capability for real time monitoring of the patient's motions and forces and without the ability for real time adjustments of the applied forces and motions. Improved technology has allowed for advancements where these devices can be designed to apply a form of tension to resist motion of the joint. These devices induce quicker recovery and are more effective at restoring proper biomechanics and improving muscle function. However, their shortcoming is in their inability to be adjusted in real-time, which is the most ideal form of a device for rehabilitation. This introduces a second class of devices beyond passive orthotics. It is comprised of "active" or powered devices, and although more complicated in design, they are definitely the most versatile. An active or powered orthotic, usually employs some type of actuator(s). In this paper we present several new advancements in the area of smart rehabilitation devices that have been developed by the Northeastern University Robotics and Mechatronics Laboratory. They are all compact, wearable and portable devices and boast re-programmable, real time computer controlled functions as the central theme behind their operation. The sensory information and computer control of the three described devices make for highly efficient and versatile systems that represent a whole new breed in wearable rehabilitation devices. Their applications range from active-assistive rehabilitation to resistance exercise and even have applications in gait training. The three devices described are: a transportable continuous passive motion elbow device, a wearable electro-rheological fluid based knee resistance device, and a wearable electrical stimulation and biofeedback knee device. Laboratory tests of the devices demonstrated that they were able to meet their design

  19. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Incore instrumentation device

    International Nuclear Information System (INIS)

    Fujita, Kazuhiko.

    1996-01-01

    A position of a detector is detected by a driving device, and the detected values are sampled by a newly disposed central processing unit for sampling the detected values depending on the sampling position of the detected values. Since the sampling position of the detected values is detected by the driving device, the sampling position for the detection values does not rely on the speed of the driving motor of the driving device. The load on the central processing device for controlling the device is lowered by newly disposing the central processing unit for sampling detected values. When the values for the position of the detector counted after conversion to digital values reach the digital values corresponding to the detection value sampling position outputted from the central processing unit for controlling the device, a counted value comparison circuit causes the central processing unit for controlling the device to sample the detection values outputted from the detector. Then, the processing speed can be increased without interruption processings, which can save the central processing unit for sampling detection values. In addition, software can be simplified and loads can be lowered. (N.H.)

  1. Reference values for blood pressure response to cycle ergometry in the first two decades of life: comparison with patients with a repaired coarctation of the aorta.

    Science.gov (United States)

    Kaafarani, Mirna; Schroer, Christian; Takken, Tim

    2017-12-01

    Hemodynamic responses to exercise are used as markers of diagnosis for cardiac diseases, systolic blood pressure (SBP) especially. However, the reference values for SBP in children at peak exertion level are outdated. This study aimed to establish current reference values for SBP, rate pressure product (RPP), and circulatory power (CircP). Data from children who previously underwent cardiopulmonary exercise testing were categorized as healthy (N = 184; age 12.6 ± 2.9 years), and CoA patients (N = 25; age 13.0 ± 3.2 years). With the Lambda-Mu-Sigma (LMS) method, percentile curves were made for SBP, CircP, and RPP in function of peak work rate (Wpeak). Data of CoA patients were used to validate the reference values. Wpeak was the best predictor of peak SBP during exercise. The prediction equations for SBP, CircP and RPP were: (0.2853 x Wpeak) + 111.46; (10.56 x Wpeak) + 2550.2 and (61.879 x Wpeak) + 19.887, respectively. CoA patients showed significantly increased values for peak SBP (Z-score 1.063 ± 1.347). This study provides reference values for SBP, RPP, and CircP at peak exercise. These values can be used for objective evaluation of participants 6-18 years of age in a Dutch population.

  2. Constraints on Short, Hard Gamma-Ray Burst Beaming Angles from Gravitational Wave Observations

    Science.gov (United States)

    Williams, D.; Clark, J. A.; Williamson, A. R.; Heng, I. S.

    2018-05-01

    The first detection of a binary neutron star merger, GW170817, and an associated short gamma-ray burst confirmed that neutron star mergers are responsible for at least some of these bursts. The prompt gamma-ray emission from these events is thought to be highly relativistically beamed. We present a method for inferring limits on the extent of this beaming by comparing the number of short gamma-ray bursts (SGRBs) observed electromagnetically with the number of neutron star binary mergers detected in gravitational waves. We demonstrate that an observing run comparable to the expected Advanced LIGO (aLIGO) 2016–2017 run would be capable of placing limits on the beaming angle of approximately θ \\in (2\\buildrel{\\circ}\\over{.} 88,14\\buildrel{\\circ}\\over{.} 15), given one binary neutron star detection, under the assumption that all mergers produce a gamma-ray burst, and that SGRBs occur at an illustrative rate of {{ \\mathcal R }}grb}=10 {Gpc}}-3 {yr}}-1. We anticipate that after a year of observations with aLIGO at design sensitivity in 2020, these constraints will improve to θ \\in (8\\buildrel{\\circ}\\over{.} 10,14\\buildrel{\\circ}\\over{.} 95), under the same efficiency and SGRB rate assumptions.

  3. Inspection device in liquid

    International Nuclear Information System (INIS)

    Nagaoka, Etsuo.

    1996-01-01

    The present invention provides an inspection device in PWR reactor core in which inspection operations are made efficient by stabilizing a posture of the device in front-to-back, vertical and left-to-right directions by a simple structure. When the device conducts inspection while running in liquid, the front and the back directions of the device main body are inspected using a visual device while changing the posture by operating a front-to-back direction propulsion device and a right-to-left direction propulsion device, and a vertical direction propulsion device against to rolling, pitching and yawing of the device main body. In this case, a spherical magnet moves freely in the gravitational direction in a vibration-damping fluid in a non-magnetic spherical shell following the change of the posture of the device main body, in which the vibrations due to the movement of the spherical magnet is settled by the vibration-damping fluid thereby stabilizing the posture of the device main body. At a typical inspection posture, the settling effect is enhanced by the attraction force between the spherical magnets in the spherical shell and each of magnetic force-attracted magnetic members disposed to the outer circumference of the shell, and the posture of the device main body can be confirmed in front-to-back, right-to-left and vertical directions by each of the posture confirming magnetic sensors. (N.H.)

  4. 78 FR 16865 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-03-19

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... certain electronic devices, including wireless communication devices, portable music and data processing...

  5. Predistortion control device and method, assembly including a predistortion control device

    NARCIS (Netherlands)

    Kokkeler, Andre B.J.

    2003-01-01

    A predistortion control device (1). The device has a first predistortion control input connectable to a power amplifier output (21); a second predistortion control input (11) connectable to a signal contact of a predistortion device; and a predistortion control output (12) connectable to a control

  6. 78 FR 1247 - Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media...

    Science.gov (United States)

    2013-01-08

    ... Wireless Communication Devices, Tablet Computers, Media Players, and Televisions, and Components Thereof... devices, including wireless communication devices, tablet computers, media players, and televisions, and... wireless communication devices, tablet computers, media players, and televisions, and components thereof...

  7. Initiation devices, initiation systems including initiation devices and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Michael A.; Condit, Reston A.; Rasmussen, Nikki; Wallace, Ronald S.

    2018-04-10

    Initiation devices may include at least one substrate, an initiation element positioned on a first side of the at least one substrate, and a spark gap electrically coupled to the initiation element and positioned on a second side of the at least one substrate. Initiation devices may include a plurality of substrates where at least one substrate of the plurality of substrates is electrically connected to at least one adjacent substrate of the plurality of substrates with at least one via extending through the at least one substrate. Initiation systems may include such initiation devices. Methods of igniting energetic materials include passing a current through a spark gap formed on at least one substrate of the initiation device, passing the current through at least one via formed through the at least one substrate, and passing the current through an explosive bridge wire of the initiation device.

  8. High energy devices versus low energy devices in orthopedics treatment modalities

    Science.gov (United States)

    Schultheiss, Reiner

    2003-10-01

    The orthopedic consensus group defined in 1997 the 42 most likely relevant parameters of orthopedic shock wave devices. The idea of this approach was to correlate the different clinical outcomes with the physical properties of the different devices with respect to their acoustical waves. Several changes in the hypothesis of the dose effect relationship have been noticed since the first orthopedic treatments. The relation started with the maximum pressure p+, followed by the total energy, the energy density; and finally the single treatment approach using high, and then the multiple treatment method using low energy. Motivated by the reimbursement situation in Germany some manufacturers began to redefine high and low energy devices independent of the treatment modality. The OssaTron as a high energy, single treatment electro hydraulic device gained FDA approval as the first orthopedic ESWT device for plantar fasciitis and, more recently, for lateral epicondylitis. Two low energy devices have now also gained FDA approval based upon a single treatment. Comparing the acoustic data, differences between the OssaTron and the other devices are obvious and will be elaborated upon. Cluster analysis of the outcomes and the acoustical data are presented and new concepts will be suggested.

  9. 77 FR 70464 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-11-26

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... wireless communication devices, portable music and data processing devices, and tablet computers, by reason...

  10. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  11. 77 FR 60720 - Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-10-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers... communication devices, portable music and data processing devices, and tablet computers, imported by Apple Inc...

  12. 78 FR 29672 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-05-21

    .... FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for... proposed rule (44 FR 13426, March 9, 1979), the Cardiovascular Device Classification Panel (the 1979 Panel... of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular devices...

  13. Recoil transporter devices

    International Nuclear Information System (INIS)

    Madhavan, N.

    2005-01-01

    The study of sparsely produced nuclear reaction products in the direction of intense primary beam is a challenging task, the pursuit of which has given rise to the advent or several types of selective devices. These range from a simple parallel plate electrostatic deflector to state-of-the-art electromagnetic separators. There is no single device which can satisfy all the requirements of an ideal recoil transporter, simultaneously. An overview of such devices and their building blocks is presented, which may help in the proper choice of the device as per the experimental requirements. (author)

  14. Multiplexed charge-locking device for large arrays of quantum devices

    Energy Technology Data Exchange (ETDEWEB)

    Puddy, R. K., E-mail: rkp27@cam.ac.uk; Smith, L. W; Chong, C. H.; Farrer, I.; Griffiths, J. P.; Ritchie, D. A.; Smith, C. G. [Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE (United Kingdom); Al-Taie, H.; Kelly, M. J. [Cavendish Laboratory, University of Cambridge, Cambridge CB3 0HE (United Kingdom); Centre for Advanced Photonics and Electronics, Electrical Engineering Division, Department of Engineering, 9 J. J. Thomson Avenue, University of Cambridge, Cambridge CB3 0FA (United Kingdom); Pepper, M. [Department of Electronic and Electrical Engineering, University College London, WC1E 7JE (United Kingdom)

    2015-10-05

    We present a method of forming and controlling large arrays of gate-defined quantum devices. The method uses an on-chip, multiplexed charge-locking system and helps to overcome the restraints imposed by the number of wires available in cryostat measurement systems. The device architecture that we describe here utilises a multiplexer-type scheme to lock charge onto gate electrodes. The design allows access to and control of gates whose total number exceeds that of the available electrical contacts and enables the formation, modulation and measurement of large arrays of quantum devices. We fabricate such devices on n-type GaAs/AlGaAs substrates and investigate the stability of the charge locked on to the gates. Proof-of-concept is shown by measurement of the Coulomb blockade peaks of a single quantum dot formed by a floating gate in the device. The floating gate is seen to drift by approximately one Coulomb oscillation per hour.

  15. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    Science.gov (United States)

    Riggert, C.; Ziegler, M.; Schroeder, D.; Krautschneider, W. H.; Kohlstedt, H.

    2014-10-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit.

  16. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    International Nuclear Information System (INIS)

    Riggert, C; Ziegler, M; Kohlstedt, H; Schroeder, D; Krautschneider, W H

    2014-01-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit. (paper)

  17. FLUIDICS DEVICE FOR ASSAY

    DEFF Research Database (Denmark)

    2007-01-01

    The present invention relates to a device for use in performing assays on standard laboratory solid supports whereon chemical entities are attached. The invention furthermore relates to the use of such a device and a kit comprising such a device. The device according to the present invention is a...

  18. Electronic security device

    Science.gov (United States)

    Eschbach, Eugene A.; LeBlanc, Edward J.; Griffin, Jeffrey W.

    1992-01-01

    The present invention relates to a security device having a control box (12) containing an electronic system (50) and a communications loop (14) over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system (50) and a detection module (72) capable of registering changes in the voltage and phase of the signal transmitted over the loop.

  19. Electronic security device

    International Nuclear Information System (INIS)

    Eschbach, E.A.; LeBlanc, E.J.; Griffin, J.W.

    1992-01-01

    The present invention relates to a security device having a control box containing an electronic system and a communications loop over which the system transmits a signal. The device is constructed so that the communications loop can extend from the control box across the boundary of a portal such as a door into a sealed enclosure into which access is restricted whereby the loop must be damaged or moved in order for an entry to be made into the enclosure. The device is adapted for detecting unauthorized entries into such enclosures such as rooms or containers and for recording the time at which such entries occur for later reference. Additionally, the device detects attempts to tamper or interfere with the operation of the device itself and records the time at which such events take place. In the preferred embodiment, the security device includes a microprocessor-based electronic system and a detection module capable of registering changes in the voltage and phase of the signal transmitted over the loop. 11 figs

  20. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  1. Three fundamental devices in one: a reconfigurable multifunctional device in two-dimensional WSe2

    Science.gov (United States)

    Dhakras, Prathamesh; Agnihotri, Pratik; Lee, Ji Ung

    2017-06-01

    The three pillars of semiconductor device technologies are (1) the p-n diode, (2) the metal-oxide-semiconductor field-effect transistor and (3) the bipolar junction transistor. They have enabled the unprecedented growth in the field of information technology that we see today. Until recently, the technological revolution for better, faster and more efficient devices has been governed by scaling down the device dimensions following Moore’s Law. With the slowing of Moore’s law, there is a need for alternative materials and computing technologies that can continue the advancement in functionality. Here, we describe a single, dynamically reconfigurable device that implements these three fundamental device functions. The device uses buried gates to achieve n- and p-channels and fits into a larger effort to develop devices with enhanced functionalities, including logic functions, over device scaling. As they are all surface conducting devices, we use one material parameter, the interface trap density of states, to describe the key figure-of-merit of each device.

  2. Devices, Distractions and Digital Literacy: "Bring Your Own Device" to Polytech

    Science.gov (United States)

    Drew, Leoni; Forbes, Dianne

    2017-01-01

    The purpose of this study is to investigate the ways polytechnic students use personal mobile devices to support their learning. This study used purposive sampling and mixed methods to generate data about student ownership and use of mobile digital devices within a single institution. Findings reveal patterns of device ownership, insights into how…

  3. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  4. Metallic spintronic devices

    CERN Document Server

    Wang, Xiaobin

    2014-01-01

    Metallic Spintronic Devices provides a balanced view of the present state of the art of metallic spintronic devices, addressing both mainstream and emerging applications from magnetic tunneling junction sensors and spin torque oscillators to spin torque memory and logic. Featuring contributions from well-known and respected industrial and academic experts, this cutting-edge work not only presents the latest research and developments but also: Describes spintronic applications in current and future magnetic recording devicesDiscusses spin-transfer torque magnetoresistive random-access memory (STT-MRAM) device architectures and modelingExplores prospects of STT-MRAM scaling, such as detailed multilevel cell structure analysisInvestigates spintronic device write and read optimization in light of spintronic memristive effectsConsiders spintronic research directions based on yttrium iron garnet thin films, including spin pumping, magnetic proximity, spin hall, and spin Seebeck effectsProposes unique solutions for ...

  5. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  6. Rewriting Classical Myths: Women's Voices in “Los motivos de Circe” and “Penélope” by Lourdes Ortiz

    Directory of Open Access Journals (Sweden)

    Morgado, Nuria

    2013-06-01

    Full Text Available The purpose of this article is to explore the mythical representations in two of the six short stories that make up Lourdes Ortiz's Voces de mujer (2007, previously published under the title Los motivos de Circe. It is well known that most rewritings of the classical myths have been faithful to the “official truth” of the original versions. But recent works in search of other meanings, have explored dimensions often hidden or blurred by the “official” version. This is the case of the short stories in this collection whose protagonists are six archetypal or mythical women and their respectful references to the biblical, Homeric and pictorial world: Eve, Circe, Penelope, Betsabé, Salomé and Gioconda. The perspective offered by Lourdes Ortiz about the history of these myths allows us to read the story from the point of view of her female heroines. As such, then, in this article I will focus on two female characters from the Homeric epic: Circe and Penelope.El propósito de este artículo es explorar las representaciones míticas en dos de los seis cuentos que componen Voces de mujer (2007, de Lourdes Ortiz, publicado anteriormente bajo el título Los Motivos de Circe. Es bien sabido que la mayoría de las reescrituras de los mitos clásicos han sido fieles a la “verdad oficial” de las versiones originales. Sin embargo, trabajos recientes han explorado las dimensiones a menudo silenciadas por la versión “oficial”. Este es el caso de los cuentos de esta colección cuyas protagonistas son seis mujeres arquetípicas o míticas, y sus referencias con el mundo bíblico, homérico y pictórico: Eva, Circe, Penélope, Betsabé, Salomé y Gioconda. La perspectiva ofrecida por Lourdes Ortiz sobre estos mitos nos permite leer la historia desde el punto de vista de sus heroínas femeninas. Este artículo se centra en dos personajes femeninos de la épica de Homero: Circe y Penélope.

  7. Delay reduction in multi-hop device-to-device communication using network coding

    KAUST Repository

    Douik, Ahmed S.; Sorour, Sameh; Al-Naffouri, Tareq Y.; Yang, Hong-Chuan; Alouini, Mohamed-Slim

    2015-01-01

    This paper considers the problem of reducing the broadcast delay of wireless networks using instantly decodable network coding (IDNC) based device-to-device (D2D) communications. In D2D-enabled networks, devices help hasten the recovery of the lost

  8. Temperature indicating device

    International Nuclear Information System (INIS)

    Angus, J.P.; Salt, D.

    1988-01-01

    A temperature indicating device comprises a plurality of planar elements some undergoing a reversible change in appearance at a given temperature the remainder undergoing an irreversible change in appearance at a given temperature. The device is useful in indicating the temperature which an object has achieved as well as its actual temperature. The reversible change is produced by liquid crystal devices. The irreversible change is produced by an absorbent surface carrying substances e.g. waxes which melt at predetermined temperatures and are absorbed by the surface; alternatively paints may be used. The device is used for monitoring processes of encapsulation of radio active waste. (author)

  9. PROPERTIES OF BULGELESS DISK GALAXIES. II. STAR FORMATION AS A FUNCTION OF CIRCULAR VELOCITY

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Linda C. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Martini, Paul; Wong, Man-Hong [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Lisenfeld, Ute [Departamento de Fisica Teorica y del Cosmos, Universidad de Granada, 18071 Granada (Spain); Boeker, Torsten [European Space Agency, Keplerlaan 1, 2200 AG Noordwijk (Netherlands); Schinnerer, Eva, E-mail: lwatson@cfa.harvard.edu [Max-Planck-Institut fuer Astronomie, Koenigstuhl 17, D-69117 Heidelberg (Germany)

    2012-06-01

    We study the relation between the surface density of gas and star formation rate in 20 moderately inclined, bulgeless disk galaxies (Sd-Sdm Hubble types) using CO(1-0) data from the IRAM 30 m telescope, H I emission line data from the VLA/EVLA, H{alpha} data from the MDM Observatory, and polycyclic aromatic hydrocarbon emission data derived from Spitzer IRAC observations. We specifically investigate the efficiency of star formation as a function of circular velocity (v{sub circ}). Previous work found that the vertical dust structure and disk stability of edge-on, bulgeless disk galaxies transition from diffuse dust lanes with large scale heights and gravitationally stable disks at v{sub circ} < 120 km s{sup -1} (M{sub *} {approx}< 10{sup 10} M{sub Sun }) to narrow dust lanes with small scale heights and gravitationally unstable disks at v{sub circ} > 120 km s{sup -1}. We find no transition in star formation efficiency ({Sigma}{sub SFR}/{Sigma}{sub Hi+H{sub 2}}) at v{sub circ} = 120 km s{sup -1} or at any other circular velocity probed by our sample (v{sub circ} = 46-190 km s{sup -1}). Contrary to previous work, we find no transition in disk stability at any circular velocity in our sample. Assuming our sample has the same dust structure transition as the edge-on sample, our results demonstrate that scale height differences in the cold interstellar medium of bulgeless disk galaxies do not significantly affect the molecular fraction or star formation efficiency. This may indicate that star formation is primarily affected by physical processes that act on smaller scales than the dust scale height, which lends support to local star formation models.

  10. Thermal energy storage devices, systems, and thermal energy storage device monitoring methods

    Science.gov (United States)

    Tugurlan, Maria; Tuffner, Francis K; Chassin, David P.

    2016-09-13

    Thermal energy storage devices, systems, and thermal energy storage device monitoring methods are described. According to one aspect, a thermal energy storage device includes a reservoir configured to hold a thermal energy storage medium, a temperature control system configured to adjust a temperature of the thermal energy storage medium, and a state observation system configured to provide information regarding an energy state of the thermal energy storage device at a plurality of different moments in time.

  11. EPICS GPIB device support

    International Nuclear Information System (INIS)

    Winans, J.

    1993-01-01

    A GPIB device support module is used to provide access to the operating parameters of a GPIB device. GPIB devices may be accessed via National Instruments 1014 cards or via Bitbus Universal Gateways. GPIB devices typically have many parameters, each of which may be thought of in terms of the standard types of database records available in EPICS. It is the job of the device support module designer to decide how the mapping of these parameters will be made to the available record types. Once this mapping is complete, the device support module may be written. The writing of the device support module consists primarily of the construction of a parameter table. This table is used to associate the database record types with the operating parameters of the GPIB instrument. Other aspects of module design include the handling of SRQ events and errors. SRQ events are made available to the device support module if so desired. The processing of an SRQ event is completely up to the designer of the module. They may be ignored, tied to event based record processing, or anything else the designer wishes. Error conditions may be handled in a similar fashion

  12. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    Energy Technology Data Exchange (ETDEWEB)

    Lijuan Zou

    2003-08-05

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm{sup 2}, the optimal radiance R could reach 0.38 mW/cm{sup 2}, and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be {approx} 10{sup -5} cm{sup 2}/Vs and {approx} 10{sup -4} cm{sup 2}/Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces.

  13. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    International Nuclear Information System (INIS)

    Lijuan Zou

    2003-01-01

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm 2 , the optimal radiance R could reach 0.38 mW/cm 2 , and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be ∼ 10 -5 cm 2 /Vs and ∼ 10 -4 cm 2 /Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces

  14. 77 FR 51571 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-08-24

    ... Music and Data Processing Devices, Computers, and Components Thereof; Notice of Receipt of Complaint... complaint entitled Wireless Communication Devices, Portable Music and Data Processing Devices, Computers..., portable music and data processing devices, computers, and components thereof. The complaint names as...

  15. Genome-Wide Search for Competing Endogenous RNAs Responsible for the Effects Induced by Ebola Virus Replication and Transcription Using a trVLP System

    Directory of Open Access Journals (Sweden)

    Zhong-Yi Wang

    2017-11-01

    Full Text Available Understanding how infected cells respond to Ebola virus (EBOV and how this response changes during the process of viral replication and transcription are very important for establishing effective antiviral strategies. In this study, we conducted a genome-wide screen to identify long non-coding RNAs (lncRNAs, circular RNAs (circRNAs, micro RNAs (miRNAs, and mRNAs differentially expressed during replication and transcription using a tetracistronic transcription and replication-competent virus-like particle (trVLP system that models the life cycle of EBOV in 293T cells. To characterize the expression patterns of these differentially expressed RNAs, we performed a series cluster analysis, and up- or down-regulated genes were selected to establish a gene co-expression network. Competing endogenous RNA (ceRNA networks based on the RNAs responsible for the effects induced by EBOV replication and transcription in human cells, including circRNAs, lncRNAs, miRNAs, and mRNAs, were constructed for the first time. Based on these networks, the interaction details of circRNA-chr19 were explored. Our results demonstrated that circRNA-chr19 targeting miR-30b-3p regulated CLDN18 expression by functioning as a ceRNA. These findings may have important implications for further studies of the mechanisms of EBOV replication and transcription. These RNAs potentially have important functions and may be promising targets for EBOV therapy.

  16. Integrated control rod monitoring device

    International Nuclear Information System (INIS)

    Saito, Katsuhiro

    1997-01-01

    The present invention provides a device in which an entire control rod driving time measuring device and a control rod position support device in a reactor building and a central control chamber are integrated systematically to save hardwares such as a signal input/output device and signal cables between boards. Namely, (1) functions of the entire control rod driving time measuring device for monitoring control rods which control the reactor power and a control rod position indication device are integrated into one identical system. Then, the entire devices can be made compact by the integration of the functions. (2) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated in a central operation board and a board in the site. Then, the place for the installation of them can be used in common in any of the cases. (3) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated to one identical system to save hardware to be used. Then, signal input/output devices and drift branching panel boards in the site and the central operation board can be saved, and cables for connecting both of the boards is no more necessary. (I.S.)

  17. 76 FR 45860 - In the Matter of Certain Electronic Devices, Including Wireless Communication Devices, Portable...

    Science.gov (United States)

    2011-08-01

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... electronic devices, including wireless communication devices, portable music and data processing devices, and...''). The complaint further alleges that an industry in the United States exists or is in the process of...

  18. Medical devices; exemption from premarket notification; class II devices; wheelchair elevator. Final order.

    Science.gov (United States)

    2013-03-04

    The Food and Drug Administration (FDA) is publishing an order granting a petition requesting exemption from premarket notification requirements for wheelchair elevator devices commonly known as inclined platform lifts and vertical platform lifts. These devices are used to provide a means for a person with a mobility impairment caused by injury or other disease to move from one level to another, usually in a wheelchair. This order exempts wheelchair elevators, class II devices, from premarket notification and establishes conditions for exemption for this device that will provide a reasonable assurance of the safety and effectiveness of the device without submission of a premarket notification (510(k)). This exemption from 510(k), subject to these conditions, is immediately in effect for wheelchair elevators. All other devices classified under FDA's wheelchair elevator regulations, including attendant-operated stair climbing devices for wheelchairs and portable platform lifts, continue to require submission of 510(k)s. FDA is publishing this order in accordance with the section of the Food, Drug, and Cosmetic Act (the FD&C Act) permitting the exemption of a device from the requirement to submit a 510(k).

  19. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  20. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2018-06-05

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  1. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  2. Fuel pattern recognition device

    International Nuclear Information System (INIS)

    Sato, Tomomi.

    1995-01-01

    The device of the present invention monitors normal fuel exchange upon fuel exchanging operation carried out in a reactor of a nuclear power plant. Namely, a fuel exchanger is movably disposed to the upper portion of the reactor and exchanges fuels. An exclusive computer receives operation signals of the fuel exchanger during operation as inputs, and outputs reactor core fuel pattern information signals to a fuel arrangement diagnosis device. An underwater television camera outputs image signals of a fuel pattern in the reactor core to an image processing device. If there is any change in the image signals for the fuel pattern as a result of the fuel exchange operation of the fuel exchanger, the image processing device outputs the change as image signals to the fuel pattern diagnosis device. The fuel pattern diagnosis device compares the pattern information signals from the exclusive computer with the image signals from the image processing device, to diagnose the result of the fuel exchange operation performed by the fuel exchanger and inform the diagnosis by means of an image display. (I.S.)

  3. 77 FR 58576 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-09-21

    ... Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof; Institution of... communication devices, portable music and data processing devices, computers, and components thereof by reason... alleges that an industry in the United States exists as required by subsection (a)(2) of section 337. The...

  4. Firewood preparation devices in 1994

    International Nuclear Information System (INIS)

    Mutikainen, A.

    1994-01-01

    A review of the market situation regarding firewood preparation devices is presented. The information was collected from the answers to a mail questionnaire. The review is assumed to include all the leading manufacturers and importers. Firewood production devices were available from 26 manufacturers. The range of models amounted to over 70. These may be divided into three categories: 1. cutting devices: the most common solution being a cross-cutting circular saw. There were only a few of these on sale as it is quite easy to include a splitting device on the same frame. 2. Splitting devices: e.g. screw splitter and hydraulically powered splitter. About 20 models are available on the markets. Cross cutting and splitting devices: these are the most popular devices. A cross-cutting circular saw with screw or hydraulic splitter is the most common type. There are about 50 models available on the markets. Cross-cutting and splitting devices are often equipped with conveyor for transferring the split wood e.g. into a trailer. Chopping devices are delivered as tractor powered devices, as electric motor powered devices or as combustion engine powered devices. Some of them are equipped with a time saving feeding device enabling the next stem to be lifted into position while the previous one is being chopped. The Finnish Work Efficiency Institute's studies show that when cross-cutting and splitting of stems into pieces of 35-50 cm in length, productivity for one operator varies in between 0.8 - 3.2 m 3 /h, depending on the device and work method used. (6 refs., 1 fig., 2 tabs.)

  5. Flaw detection device

    International Nuclear Information System (INIS)

    Sasahara, Toshihiko

    1998-01-01

    The present invention provides a device for detecting welded portions of a reactor pressure vessel. Namely, the device of the present invention comprises (1) a casing to be disposed on the surface to be detected, (2) a probe driving means loaded to the casing, (3) a probe driven along the surface to be detected and (4) a pressure reduction means for keeping the hollow portion in the casing to an evacuated atmosphere. The casing comprises a flexible suction edge to be tightly in contact with the surface to be tested for maintaining the air tight state, (6) a guide wheel for moving the casing along the surface to be tested and (7) a handle for performing transferring operation. The flaw detection device thus constituted has following features. The working efficiency upon conducting detection is improved. The influence of the weight of the device on the detection is small. The device can be applied on the surface of a nonmagnetic material. The efficiency for the flaw detection can be improved. (I.S.)

  6. Fuel inspection device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi.

    1990-01-01

    The fuel inspection device of the present invention has a feature of obtaining an optimum illumination upon fuel rod interval inspection operation in a fuel pool. That is, an illumination main body used underwater is connected to a cable which is led out on a floor. A light control device is attached to the other end of the cable and an electric power cable is connected to the light control device. A light source (for example, incandescent lamp) is incorporated in the casing of the illumination main body, and a diffusion plate is disposed at the front to provide a plane light source. The light control device has a light control knob capable of remote-controlling the brightness of the light of the illumination main body. In the fuel inspection device thus constituted, halation is scarcely caused on the image screen upon inspection of fuels by a submerged type television camera to facilitate control upon inspection. Accordingly, efficiency of the fuel inspection can be improved to shorten the operation time. (I.S.)

  7. Medical Devices; Immunology and Microbiology Devices; Classification of the Device To Detect and Identify Microbial Pathogen Nucleic Acids in Cerebrospinal Fluid. Final order.

    Science.gov (United States)

    2017-10-20

    The Food and Drug Administration (FDA or we) is classifying the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid into class II (special controls). The special controls that will apply to the device type are identified in this order and will be part of the codified language for the device to detect and identify microbial pathogen nucleic acids in cerebrospinal fluid’s classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  8. Smart devices are different

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Bhattacharya, Sourav

    2015-01-01

    research results. This is due to variations in training and test device hardware and their operating system characteristics among others. In this paper, we systematically investigate sensor-, device- and workload-specific heterogeneities using 36 smartphones and smartwatches, consisting of 13 different...... device models from four manufacturers. Furthermore, we conduct experiments with nine users and investigate popular feature representation and classification techniques in HAR research. Our results indicate that on-device sensor and sensor handling heterogeneities impair HAR performances significantly...

  9. Rooting an Android Device

    Science.gov (United States)

    2015-09-01

    1. Overview The purpose of this document is to demonstrate how to gain administrative privileges on an Android device. The term “rooting” is...is applicable for the Samsung Galaxy S3 as well as many other Android devices, but there are several steps involved in rooting an Android device (as...root access has been granted. 4. Conclusion This document serves as a tutorial on how to grant user administrative privilege to an Android device by

  10. Novel Magnetic Devices

    National Research Council Canada - National Science Library

    Schuller, Ivan

    2007-01-01

    ...: ballistic magnetoresistance, magnetic field proximity effect and spin drag. These three phenomena would then be exploited for the design of novel device architectures and to investigate the physical principles behind these devices...

  11. Evaluating imaging devices

    International Nuclear Information System (INIS)

    Rollo, F.D.

    1977-01-01

    The performance of any imaging device depends on two principal factors inherent to the device, namely, plane sensitivity and spatial resolution. These factors may be defined as follows: plane sensitivity is the counts per second recorded by the imaging device for each disintegration per second per square centimeter occurring within a plane sheet of radioactivity. Spatial resolution may be defined as the fidelity with which the imaging device reproduces the activity distribution of an object in the image plane. In all imaging devices, a trade-off exists between these two parameters; that is, as sensitivity improves, spatial resolution is degraded, and vice versa. Therefore, to fully evaluate an imaging system a technique should be selected that measures both parameters and reflects the trade-off between the two. In addition, the method should approximate the clinical problem, namely, the detection of a focal lesion within an activity distribution. Several methods have been described to evaluate nuclear imaging devices. The more common techniques include the use of organ phantoms, bar phantoms, line-spread functions, modulation transfer functions, contrast efficiency functions, and performance index functions. Each of these techniques is briefly described in this chapter, and their advantages and disadvantages are discussed. In addition, a phantom that can be used to simply and completely measure overall imaging system performance is described

  12. Measurement of the CP-violating phase $\\beta$ in $B^0\\rightarrow J/\\psi \\pi^+\\pi^-$ decays and limits on penguin effects

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bertolin, Alessandro; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brett, David; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casanova Mohr, Raimon; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew Christopher; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Di Domenico, Antonio; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gascon, David; Gaspar, Clara; Gastaldi, Ugo; Gauld, Rhorry; Gavardi, Laura; Gazzoni, Giulio; Geraci, Angelo; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Gianì, Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, Vladimir; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Lohn, Stefan; Longstaff, Iain; Lopes, Jose; Lowdon, Peter; Lucchesi, Donatella; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Moggi, Niccolò; Molina Rodriguez, Josue; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Otto, Adam; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Pesen, Erhan; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz, Hugo; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skillicorn, Ian; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Steinkamp, Olaf; Stenyakin, Oleg; Sterpka, Christopher Francis; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Todd, Jacob; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viana Barbosa, Joao Vitor; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Whitehead, Mark; Wiedner, Dirk; Wilkinson, Guy; Wilkinson, Michael; Williams, Matthew; Williams, Mike; Wilschut, Hans; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Xu, Zhirui; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang

    2015-01-01

    Time-dependent CP violation is measured in the $B^0\\rightarrow J/\\psi\\pi^+\\pi^-$ channel for each $\\pi^+\\pi^-$ resonant final state using data collected with an integrated luminosity of 3.0 fb$^{-1}$ in $pp$ collisions using the LHCb detector. The final state with the largest rate, $J/\\psi\\rho^0(770)$, is used to measure the CP-violating angle $2\\beta^{\\rm eff}$ to be $(41.7\\pm 9.6_{-6.3}^{+2.8})^{\\circ}$. This result can be used to limit the size of penguin amplitude contributions to CP violation measurements in, for example, $B_s^0\\rightarrow J/\\psi\\phi$ decays. Assuming approximate SU(3) flavour symmetry and neglecting higher order diagrams, the shift in the CP-violating phase $\\phi_s$ is limited to be within the interval [$-1.05^\\circ$, +$1.18^\\circ$] at 95% confidence level. Changes to the limit due to SU(3) symmetry breaking effects are also discussed.

  13. Ergonomic material-handling device

    Science.gov (United States)

    Barsnick, Lance E.; Zalk, David M.; Perry, Catherine M.; Biggs, Terry; Tageson, Robert E.

    2004-08-24

    A hand-held ergonomic material-handling device capable of moving heavy objects, such as large waste containers and other large objects requiring mechanical assistance. The ergonomic material-handling device can be used with neutral postures of the back, shoulders, wrists and knees, thereby reducing potential injury to the user. The device involves two key features: 1) gives the user the ability to adjust the height of the handles of the device to ergonomically fit the needs of the user's back, wrists and shoulders; and 2) has a rounded handlebar shape, as well as the size and configuration of the handles which keep the user's wrists in a neutral posture during manipulation of the device.

  14. Materials for electrochemical device safety

    Science.gov (United States)

    Vissers, Daniel R.; Amine, Khalil; Thackeray, Michael M.; Kahaian, Arthur J.; Johnson, Christopher S.

    2015-04-07

    An electrochemical device includes a thermally-triggered intumescent material or a gas-triggered intumescent material. Such devices prevent or minimize short circuits in a device that could lead to thermal run-away. Such devices may include batteries or supercapacitors.

  15. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  16. Plasma shutdown device

    International Nuclear Information System (INIS)

    Hosogane, Nobuyuki; Nakayama, Takahide.

    1985-01-01

    Purpose: To prevent concentration of plasma currents to the plasma center upon plasma shutdown in a torus type thermonuclear device by the injection of fuels to the plasma center thereby prevent plasma disruption at the plasma center. Constitution: The plasma shutdown device comprises a plasma current measuring device that measures the current distribution of plasmas confined within a vacuum vessel and outputs a control signal for cooling the plasma center when the plasma currents concentrate to the plasma center and a fuel supply device that supplies fuels to the plasma center for cooling the center. The fuels are injected in the form of pellets into the plasmas. The direction and the velocity of the injection are set such that the pellets are ionized at the center of the plasmas. (Horiuchi, T.)

  17. Photovoltaic device and method

    Science.gov (United States)

    Cleereman, Robert J; Lesniak, Michael J; Keenihan, James R; Langmaid, Joe A; Gaston, Ryan; Eurich, Gerald K; Boven, Michelle L

    2015-01-27

    The present invention is premised upon an improved photovoltaic device ("PVD") and method of use, more particularly to an improved photovoltaic device with an integral locator and electrical terminal mechanism for transferring current to or from the improved photovoltaic device and the use as a system.

  18. Communication equipment radiation resistance ensurance

    International Nuclear Information System (INIS)

    Myrova, L.O.; Chelizhenko, A.Z.

    1983-01-01

    A review of works on radiation resistance of electronic equipment (epsilon epsilon) for 15 years is presented. The effect of ionizing radiation appearing as a result of nuclear explosions in nuclear facilities and in outerspace on epsilon epsilon has been considered. Types of radiation effects in epsilon epsilon, radiation effect on semiconductor devices and integrated circUits, types of epsilon epsilon failures, as well as the procass of radiation-resistant epsilon epsilon designing and selection of its main parameters have been described. The methods of epsilon epsilon flowsheet optimization, application of mathematical simulation and peculiarities of ensurance of epsilon epsilon radiation resistance of communication systems are considered. Peculiarities of designing of radiation-resistant quartz generators, secondary power supply sources and amplifiers are discussed

  19. Magnet-assisted device-level alignment for the fabrication of membrane-sandwiched polydimethylsiloxane microfluidic devices

    International Nuclear Information System (INIS)

    Lu, J-C; Liao, W-H; Tung, Y-C

    2012-01-01

    Polydimethylsiloxane (PDMS) microfluidic device is one of the most essential techniques that advance microfluidics research in recent decades. PDMS is broadly exploited to construct microfluidic devices due to its unique and advantageous material properties. To realize more functionalities, PDMS microfluidic devices with multi-layer architectures, especially those with sandwiched membranes, have been developed for various applications. However, existing alignment methods for device fabrication are mainly based on manual observations, which are time consuming, inaccurate and inconsistent. This paper develops a magnet-assisted alignment method to enhance device-level alignment accuracy and precision without complicated fabrication processes. In the developed alignment method, magnets are embedded into PDMS layers at the corners of the device. The paired magnets are arranged in symmetric positions at each PDMS layer, and the magnetic attraction force automatically pulls the PDMS layers into the aligned position during assembly. This paper also applies the method to construct a practical microfluidic device, a tunable chaotic micromixer. The results demonstrate the successful operation of the device without failure, which suggests the accurate alignment and reliable bonding achieved by the method. Consequently, the fabrication method developed in this paper is promising to be exploited to construct various membrane-sandwiched PDMS microfluidic devices with more integrated functionalities to advance microfluidics research. (paper)

  20. Hot gas handling device and motorized vehicle comprising the device

    NARCIS (Netherlands)

    Klein Geltink, J.; Beukers, A.; Van Tooren, M.J.L.; Koussios, S.

    2012-01-01

    The invention relates to a device for handling hot exhaust gasses discharged from an internal combustion engine. The device comprises a housing (2), enclosing a space (3) for transporting the exhaust gasses. The housing (2) is provided with an entrance - opening (4) for the exhaust gasses discharged

  1. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  2. Output hardcopy devices

    CERN Document Server

    Durbeck, Robert

    1988-01-01

    Output Hardcopy Devices provides a technical summary of computer output hardcopy devices such as plotters, computer output printers, and CRT generated hardcopy. Important related technical areas such as papers, ribbons and inks, color techniques, controllers, and character fonts are also covered. Emphasis is on techniques primarily associated with printing, as well as the plotting capabilities of printing devices that can be effectively used for computer graphics in addition to their various printing functions. Comprised of 19 chapters, this volume begins with an introduction to vector and ras

  3. Powering biomedical devices

    CERN Document Server

    Romero, Edwar

    2013-01-01

    From exoskeletons to neural implants, biomedical devices are no less than life-changing. Compact and constant power sources are necessary to keep these devices running efficiently. Edwar Romero's Powering Biomedical Devices reviews the background, current technologies, and possible future developments of these power sources, examining not only the types of biomedical power sources available (macro, mini, MEMS, and nano), but also what they power (such as prostheses, insulin pumps, and muscular and neural stimulators), and how they work (covering batteries, biofluids, kinetic and ther

  4. 78 FR 24775 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2013-04-26

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers... '826 patent''). The complaint further alleges the existence of a domestic industry. The Commission's...

  5. 77 FR 38826 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2012-06-29

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof, Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers... further alleges the existence of a domestic industry. The Commission's notice of investigation named Apple...

  6. 78 FR 12785 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2013-02-25

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Commission Decision... importation of certain wireless communication devices, portable music and data processing devices, computers... further alleges the existence of a domestic industry. The Commission's notice of investigation named Apple...

  7. Humanitarian Use Device and Humanitarian Device Exemption regulatory programs: pros and cons.

    Science.gov (United States)

    Bernad, Daniel Maxwell

    2009-03-01

    The US FDA established the Humanitarian Use Device (HUD) and Humanitarian Device Exemption (HDE) program to encourage medical device firms to address rare diseases. Despite being in existence for over a decade, there has only been one peer-reviewed publication examining this field. The objective of this report is to investigate how the HUD/HDE program differs from the standard regulatory system, discuss its potential advantages and disadvantages, and to speculate which humanitarian devices will be brought to market within the next 5 years. A total of 40 semistructured interviews with stakeholders, representing approximately half (n = 20, 49%) of the firms that have successfully obtained HDE-approved products, were performed in order to acquire the primary data for this paper. There appear to be short-term gains and long-term drains associated with launching humanitarian devices to market. This report aims to provide sponsors with information that may allow them to make better decisions during their product development of humanitarian devices and may, hopefully, also play a role in encouraging other sponsors to take the necessary steps forward in helping to find treatments for patients with rare diseases.

  8. 2002 Industry Studies: News Media

    Science.gov (United States)

    2002-01-01

    USAF CAPT John W. Coleman II, USN Reserve Col Christos Dellas , Greek Army Col Tim Fletcher USAF Lt Col Tim Malinski USAF Lt Col Deb Martinez USAF Ms...Majority Support Government Restrictions on War Coverage,” Washington Post, 29 November 2001, Sec. C, p.1. 54 Lucia Moses, “E&P Survey: Circ Bump was...Afghan War,” The Washington Post, 7 December 2001, Sec. A, p. 43. Moses, Lucia , “E&P Survey: Circ Bump was Modest,” Editor & Publisher, 22 April 2002

  9. 77 FR 14272 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-03-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus... AND MICROBIOLOGY DEVICES 0 1. The authority citation for 21 CFR part 866 continues to read as follows...

  10. 21 CFR 882.5050 - Biofeedback device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Biofeedback device. 882.5050 Section 882.5050 Food... DEVICES NEUROLOGICAL DEVICES Neurological Therapeutic Devices § 882.5050 Biofeedback device. (a) Identification. A biofeedback device is an instrument that provides a visual or auditory signal corresponding to...

  11. 77 FR 52759 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers and...

    Science.gov (United States)

    2012-08-30

    ... Devices, Portable Music and Data Processing Devices, Computers and Components Thereof; Notice of... communication devices, portable music and data processing devices, computers and components thereof by reason of... complaint further alleges the existence of a domestic industry. The Commission's notice of investigation...

  12. Plasma facing device of thermonuclear device

    International Nuclear Information System (INIS)

    Sumita, Hideo; Ioki, Kimihiro.

    1993-01-01

    The present invention improves integrity of thermal structures of a plasma facing device. That is, in the plasma facing device, an armour block portion from a metal cooling pipe to a carbon material comprises a mixed material of the metal as the constituent material of the cooling pipe and ceramics. Then, the mixing ratio of the composition is changed continuously or stepwise to suppress peakings of remaining stresses upon production and thermal stresses upon exertion of thermal loads. Accordingly, thermal integrity of the structural materials can further be improved. In this case, a satisfactory characteristic can be obtained also by using ceramics instead of carbon for the mixed material, and the characteristic such as heat expansion coefficient is similar to that of the armour tile. (I.S.)

  13. Cybersecurity for Connected Diabetes Devices.

    Science.gov (United States)

    Klonoff, David C

    2015-04-16

    Diabetes devices are increasingly connected wirelessly to each other and to data-displaying reader devices. Threats to the accurate flow of information and commands may compromise the function of these devices and put their users at risk of health complications. Sound cybersecurity of connected diabetes devices is necessary to maintain confidentiality, integrity, and availability of the data and commands. Diabetes devices can be hacked by unauthorized agents and also by patients themselves to extract data that are not automatically provided by product software. Unauthorized access to connected diabetes devices has been simulated and could happen in reality. A cybersecurity standard designed specifically for connected diabetes devices will improve the safety of these products and increase confidence of users that the products will be secure. © 2015 Diabetes Technology Society.

  14. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Dick Sawyer

    1998-01-01

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  15. Radiation emitting devices act

    International Nuclear Information System (INIS)

    1970-01-01

    This Act, entitled the Radiation Emitting Devices Act, is concerned with the sale and importation of radiation emitting devices. Laws relating to the sale, lease or import, labelling, advertising, packaging, safety standards and inspection of these devices are listed as well as penalties for any person who is convicted of breaking these laws

  16. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  17. 76 FR 69034 - Microbiology Devices; Classification of In Vitro Diagnostic Device for Yersinia Species Detection

    Science.gov (United States)

    2011-11-07

    ... Drug Administration 21 CFR Part 866 Microbiology Devices; Classification of In Vitro Diagnostic Device... CFR Part 866 [Docket No. FDA-2011-N-0729] Microbiology Devices; Classification of In Vitro Diagnostic... of the Microbiology Devices Advisory Panel (the panel). FDA is publishing in this document the...

  18. 76 FR 28689 - Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus Species Detection

    Science.gov (United States)

    2011-05-18

    .... FDA-2011-N-0103] Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus... of the Microbiology Devices Advisory Panel (the Panel). In addition, the proposed rule would... in the Federal Register. 1. Transcript of the FDA Microbiology Devices Panel meeting, March 7, 2002...

  19. Organic bistable light-emitting devices

    Science.gov (United States)

    Ma, Liping; Liu, Jie; Pyo, Seungmoon; Yang, Yang

    2002-01-01

    An organic bistable device, with a unique trilayer structure consisting of organic/metal/organic sandwiched between two outmost metal electrodes, has been invented. [Y. Yang, L. P. Ma, and J. Liu, U.S. Patent Pending, U.S. 01/17206 (2001)]. When the device is biased with voltages beyond a critical value (for example 3 V), the device suddenly switches from a high-impedance state to a low-impedance state, with a difference in injection current of more than 6 orders of magnitude. When the device is switched to the low-impedance state, it remains in that state even when the power is off. (This is called "nonvolatile" phenomenon in memory devices.) The high-impedance state can be recovered by applying a reverse bias; therefore, this bistable device is ideal for memory applications. In order to increase the data read-out rate of this type of memory device, a regular polymer light-emitting diode has been integrated with the organic bistable device, such that it can be read out optically. These features make the organic bistable light-emitting device a promising candidate for several applications, such as digital memories, opto-electronic books, and recordable papers.

  20. Semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2011-03-15

    Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  1. Secure-Network-Coding-Based File Sharing via Device-to-Device Communication

    OpenAIRE

    Wang, Lei; Wang, Qing

    2017-01-01

    In order to increase the efficiency and security of file sharing in the next-generation networks, this paper proposes a large scale file sharing scheme based on secure network coding via device-to-device (D2D) communication. In our scheme, when a user needs to share data with others in the same area, the source node and all the intermediate nodes need to perform secure network coding operation before forwarding the received data. This process continues until all the mobile devices in the netw...

  2. Positioning devices for patients

    International Nuclear Information System (INIS)

    Heavens, M.

    1981-01-01

    It has been suggested that it is very important to position patients reproducibly at different stages of radiotherapy treatment planning and treatment, or similar procedures. Devices have been described for positioning a patient's upper and lower thorax. This invention provides reproducible positioning for a female patient's breasts, for example in planning treatment of and treating breast tumours. The patient is placed prone, using for example an upper thorax device. A support device is placed central to and beneath her breasts to partially displace them outwards. The device may be triangular in section with one apex contacting the chest wall at the sternum. Restraining straps may be provided to hold the breasts against the support device. Means may be provided to take a healthy breast from the path of radiation through the tumour. (author)

  3. 78 FR 26786 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  4. 76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  5. Solar panel foundation device

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1983-03-29

    A transportable solar panel foundation device which has a bottom member, at least one upstanding side member, and an essentially open top. The side members are angled to permit nesting of a plurality of the foundation devices, and reinforcement pads are carried by the foundation device to support legs for one or more solar panels.

  6. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  7. After-heat removing device

    International Nuclear Information System (INIS)

    Iwashige, Kengo; Otsuka, Masaya; Yokoyama, Iwao; Yamakawa, Masanori.

    1990-01-01

    The present invention concerns an after-heat removing device for first reactors. A heat accumulation portion provided in a cooling channel of an after-heat removing device is disposed before a coil-like heat conduction pipe for cooling of the after-heat removing device. During normal reactor operation, the temperature in the heat accumulation portion is near the temperature of the high temperature plenum due to heat conduction and heat transfer from the high temperature plenum. When the reactor is shutdown and the after-heat removing device is started, coolants cooled in the air cooler start circulation. The coolants arriving at the heat accumulation portion deprive heat from the heat accumulation portion and, ion turn, increase their temperature and then reach the cooling coil. Subsequently, the heat calorie possessed in the heat accumulation portion is reduced and the after-heat removing device is started for the operation at a full power. This can reduce the thermal shocks applied to the cooling coil or structures in a reactor vessel upon starting the after-heat removing device. (I.N.)

  8. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  9. Hardware device binding and mutual authentication

    Science.gov (United States)

    Hamlet, Jason R; Pierson, Lyndon G

    2014-03-04

    Detection and deterrence of device tampering and subversion by substitution may be achieved by including a cryptographic unit within a computing device for binding multiple hardware devices and mutually authenticating the devices. The cryptographic unit includes a physically unclonable function ("PUF") circuit disposed in or on the hardware device, which generates a binding PUF value. The cryptographic unit uses the binding PUF value during an enrollment phase and subsequent authentication phases. During a subsequent authentication phase, the cryptographic unit uses the binding PUF values of the multiple hardware devices to generate a challenge to send to the other device, and to verify a challenge received from the other device to mutually authenticate the hardware devices.

  10. Partial Device Fingerprints

    NARCIS (Netherlands)

    Ciere, M.; Hernandez Ganan, C.; van Eeten, M.J.G.

    2017-01-01

    In computing, remote devices may be identified by means of device fingerprinting, which works by collecting a myriad of clientside attributes such as the device’s browser and operating system version, installed plugins, screen resolution, hardware artifacts, Wi-Fi settings, and anything else

  11. Incore monitoring device

    International Nuclear Information System (INIS)

    Tai, Ichiro; Shirayama, Shin-pei; Nozaki, Shin-ichi.

    1978-01-01

    Purpose: To provide an incore monitoring device wherein both radiation monitoring and acoustic monitoring are carried out simultaneously by one detector, whereby installation of the device and signal pick-up are facilitated. Incore conditions are accurately grasped. Constitution: When a neutron is irradiated in a state where a DC voltage is applied between the electrode and the vessel in the device, an ionization current is occured by (n.γ) reaction of the transformed substance as in an ionization chamber, Accordingly, a voltage drop occurs at both ends of the resistor of the radiation signal processing system, as a result of which a neutron flux can be detected. Further, when a sound is generated in the reactor, the monitoring device bottom wall which formed by a piezoelectric element detects the sound-waves. This output signal is picked up by the acoustic signal processing system to judge the generation of sound. (Aizawa, K.)

  12. High-Fidelity Piezoelectric Audio Device

    Science.gov (United States)

    Woodward, Stanley E.; Fox, Robert L.; Bryant, Robert G.

    2003-01-01

    ModalMax is a very innovative means of harnessing the vibration of a piezoelectric actuator to produce an energy efficient low-profile device with high-bandwidth high-fidelity audio response. The piezoelectric audio device outperforms many commercially available speakers made using speaker cones. The piezoelectric device weighs substantially less (4 g) than the speaker cones which use magnets (10 g). ModalMax devices have extreme fabrication simplicity. The entire audio device is fabricated by lamination. The simplicity of the design lends itself to lower cost. The piezoelectric audio device can be used without its acoustic chambers and thereby resulting in a very low thickness of 0.023 in. (0.58 mm). The piezoelectric audio device can be completely encapsulated, which makes it very attractive for use in wet environments. Encapsulation does not significantly alter the audio response. Its small size (see Figure 1) is applicable to many consumer electronic products, such as pagers, portable radios, headphones, laptop computers, computer monitors, toys, and electronic games. The audio device can also be used in automobile or aircraft sound systems.

  13. Nuclear fuel shipping inspection device

    International Nuclear Information System (INIS)

    Takahashi, Toshio; Hada, Koji.

    1988-01-01

    Purpose: To provide an nuclear fuel shipping inspection device having a high detection sensitivity and capable of obtaining highly reliable inspection results. Constitution: The present invention concerns a device for distinguishing a fuel assembly having failed fuel rods in LMFBR type reactors. Coolants in a fuel assembly to be inspected are collected by a sampling pipeway and transferred to a filter device. In the filter device, granular radioactive corrosion products (CP) in the coolants are captured, to reduce the background. The coolants, after being passed through the filter device, are transferred to an FP catching device and gamma-rays of iodine and cesium nuclides are measured in FP radiation measuring device. Subsequently, the coolants transferred to a degasing device to separate rare gas FP in the coolants from the liquid phase. In a case if rare gas fission products are detected by the radiation detector, it means that there is a failed fuel rod in the fuel assembly to be inspected. Since the CP and the soluble FP are separated and extracted for the radioactivity measurement, the reliability can be improved. (Kamimura, M.)

  14. Wide-field 12CO (J=2-1) and 13CO (J=2-1) Observations toward the Aquila Rift and Serpens Molecular Cloud Complexes. I. Molecular Clouds and Their Physical Properties

    Science.gov (United States)

    Nakamura, Fumitaka; Dobashi, Kazuhito; Shimoikura, Tomomi; Tanaka, Tomohiro; Onishi, Toshikazu

    2017-03-01

    We present the results of wide-field 12CO (J=2{--}1) and 13CO (J=2{--}1) observations toward the Aquila Rift and Serpens molecular cloud complexes (25^\\circ < l< 33^\\circ and 1^\\circ < b< 6^\\circ ) at an angular resolution of 3.‧4 (≈ 0.25 pc) and at a velocity resolution of 0.079 km s-1 with velocity coverage of -5 {km} {{{s}}}-1< {V}{LSR}< 35 {km} {{{s}}}-1. We found that the 13CO emission better traces the structures seen in the extinction map, and derived the {X}{13{CO}}-factor of this region. Applying SCIMES to the 13CO data cube, we identified 61 clouds and derived their mass, radii, and line widths. The line width-radius relation of the identified clouds basically follows those of nearby molecular clouds. The majority of the identified clouds are close to virial equilibrium, although the dispersion is large. By inspecting the 12CO channel maps by eye, we found several arcs that are spatially extended to 0.°2-3° in length. In the longitude-velocity diagrams of 12CO, we also found two spatially extended components that appear to converge toward Serpens South and the W40 region. The existence of two components with different velocities and arcs suggests that large-scale expanding bubbles and/or flows play a role in the formation and evolution of the Serpens South and W40 cloud.

  15. Relationship between segmental thallium-201 uptake and regional myocardial blood flow in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Nichols, A.B.; Weiss, M.B.; Sciacca, R.R.; Cannon, P.J.; Blood, D.K.

    1983-01-01

    The relationship between the spatial distribution of thallium-201 in myocardial perfusion scintigrams and the distribution of left ventricular regional myocardial blood flow was examined in 25 patients undergoing coronary arteriography. Thallium-201 myocardial scintigrams were obtained after symptom-limited exercise and after a 4 hr delay. Regional myocardial blood flow was measured by the xenon-133 clearance method in patients at rest and during rapid atrial pacing to a double product comparable with that achieved during exercise stress testing. Patterns of regional thallium-201 activity and regional myocardial blood flow, recorded in similar left anterior oblique projections, were compared for left ventricular segments supplied by the left anterior descending (LAD) and left circumflex (CIRC) arteries. In 11 patients without significant lesions of the left coronary artery (group 1), thallium-201 was homogeneously distributed in the LAD and CIRC distributions in scintigrams taken during peak exercise; these scintigrams correspond to homogeneous regional myocardial blood flow in the LAD and CIRC regions during pacing-induced stress. In 14 patients with significant lesions of the left coronary artery (group 2), ratios of regional thallium-201 activity in the LAD and CIRC distributions of exercise scintigrams correlated well (r . .84) with ratios of regional myocardial blood flow measured during rapid pacing. Background subtraction altered the relationship between relative thallium-201 uptake and regional myocardial blood flow, causing overestimation of the magnitude of flow reduction on exercise scintigrams

  16. Delay reduction in multi-hop device-to-device communication using network coding

    KAUST Repository

    Douik, Ahmed S.

    2015-08-12

    This paper considers the problem of reducing the broadcast delay of wireless networks using instantly decodable network coding (IDNC) based device-to-device (D2D) communications. In D2D-enabled networks, devices help hasten the recovery of the lost packets of devices in their transmission range by sending network coded packets. To solve the problem, the different events occurring at each device are identified so as to derive an expression for the probability distribution of the decoding delay. The joint optimization problem over the set of transmitting devices and the packet combinations of each is formulated. Due to the high complexity of finding the optimal solution, this paper focuses on cooperation without interference between the transmitting users. The optimal solution, in such interference-less scenario, is expressed using a graph theory approach by introducing the cooperation graph. Extensive simulations compare the decoding delay experienced in the Point to Multi-Point (PMP), the fully connected D2D (FC-D2D) and the more practical partially connected D2D (PC-D2D) configurations and suggest that the PC-D2D outperforms the FC-D2D in all situations and provides an enormous gain for poorly connected networks.

  17. Triboluminescent tamper-indicating device

    Science.gov (United States)

    Johnston, Roger G.; Garcia, Anthony R. E.

    2002-01-01

    A tamper-indicating device is described. The device has a transparent or translucent cylindrical body that includes triboluminescent material, and an outer opaque layer that prevents ambient light from entering. A chamber in the body holds an undeveloped piece of photographic film bearing an image. The device is assembled from two body members. One of the body members includes a recess for storing film and an optical assembly that can be adjusted to prevent light from passing through the assembly and exposing the film. To use the device with a hasp, the body members are positioned on opposite sides of a hasp, inserted through the hasp, and attached. The optical assembly is then manipulated to allow any light generated from the triboluminescent materials during a tampering activity that damages the device to reach the film and destroy the image on the film.

  18. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  19. Diamond semiconducting devices

    International Nuclear Information System (INIS)

    Polowczyk, M.; Klugmann, E.

    1999-01-01

    Many efforts to apply the semiconducting diamond for construction of electronic elements: resistors, thermistors, photoresistors, piezoresistors, hallotrons, pn diodes, Schottky diodes, IMPATT diodes, npn transistor, MESFETs and MISFETs are reviewed. Considering the possibilities of acceptor and donor doping, electrical resistivity and thermal conductivity of diamond as well as high electric-field breakdown points, that diamond devices could be used at about 30-times higher frequency and more then 8200 times power than silicon devices. Except that, due to high heat resistant of diamond, it is concluded that diamond devices can be used in environment at high temperature, range of 600 o C. (author)

  20. A gauge device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1982-01-01

    A readily transportable device of relative light weight comprising a pair of tensioned guides for providing accurate and stable reference planes. An embodiment comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a pair of arcuate compression members. The tensioned guides provide planes of reference for measuring devices moved therealong adjacent to a component to be measured. The device is especially useful for making on-site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (author)

  1. Digital communication device

    DEFF Research Database (Denmark)

    2005-01-01

    The invention concerns a digital communication device like a hearing aid or a headset. The hearing aid or headset has a power supply, a signal processing device, means for receiving a wireless signal and a receiver or loudspeaker, which produces an audio signal based on a modulated pulsed signal...... point is provided which is in electrical contact with the metal of the metal box and whereby this third connection point is connected to the electric circuitry of the communication device at a point having a stable and well defined electrical potential. In this way the electro-and magnetic radiation...

  2. Resource management for device-to-device underlay communication

    CERN Document Server

    Song, Lingyang; Xu, Chen

    2013-01-01

    Device-to-Device (D2D) communication will become a key feature supported by next generation cellular networks, a topic of enormous importance to modern communication. Currently, D2D serves as an underlay to the cellular network as a means to increase spectral efficiency. Although D2D communication brings large benefits in terms of system capacity, it also causes interference as well as increased computation complexity to cellular networks as a result of spectrum sharing. Thus, efficient resource management must be performed to guarantee a target performance level of cellular communication.This

  3. Articulating feedstock delivery device

    Science.gov (United States)

    Jordan, Kevin

    2013-11-05

    A fully articulable feedstock delivery device that is designed to operate at pressure and temperature extremes. The device incorporates an articulating ball assembly which allows for more accurate delivery of the feedstock to a target location. The device is suitable for a variety of applications including, but not limited to, delivery of feedstock to a high-pressure reaction chamber or process zone.

  4. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  5. The SMOS Validation Campaign 2010 in the Upper Danube Catchment: A Data Set for Studies of Soil Moisture, Brightness Temperature, and Their Spatial Variability Over a Heterogeneous Land Surface

    DEFF Research Database (Denmark)

    T. dall' Amico, Johanna; Schlenz, Florian; Loew, Alexander

    2013-01-01

    resolutions from roughly 400 m to 2 km. The contemporaneous distributed ground measurements include surface soil moisture, a detailed land cover map, vegetation height, phenology, and biomass. Furthermore, several ground stations provide continuous measurements of soil moisture and soil temperature as well...... infrared and L-band passive microwave data were collected together with spatially distributed in situ measurements. Two airborne radiometers, EMIRAD and HUT-2D, were used during the campaigns providing two complementary sets of measurements at incidence angles from 0$^{circ}$ to 40$^{circ}$ and with ground...

  6. Organic 'Plastic' Optoelectronic Devices

    International Nuclear Information System (INIS)

    Sariciftci, N.S.

    2006-01-01

    Recent developments on conjugated polymer based photovoltaic diodes and photoactive organic field effect transistors (photOFETs) are discussed. The photophysics of such devices is based on the photoinduced charge transfer from donor type semiconducting conjugated polymers onto acceptor type conjugated polymers or acceptor molecules such as Buckminsterfullerene, C 6 0. Potentially interesting applications include sensitization of the photoconductivity and photovoltaic phenomena as well as photoresponsive organic field effect transistors (photOFETs). Furthermore, organic polymeric/inorganic nanoparticle based 'hybrid' solar cells will be discussed. This talk gives an overview of materials' aspect, charge-transport, and device physics of organic diodes and field-effect transistors. Furthermore, due to the compatibility of carbon/hydrogen based organic semiconductors with organic biomolecules and living cells there can be a great opportunity to integrate such organic semiconductor devices (biOFETs) with the living organisms. In general the largely independent bio/lifesciences and information technology of today, can be thus bridged in an advanced cybernetic approach using organic semiconductor devices embedded in bio-lifesciences. This field of bio-organic electronic devices is proposed to be an important mission of organic semiconductor devices

  7. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  8. Control rod drive hydraulic device

    International Nuclear Information System (INIS)

    Takekawa, Toru.

    1994-01-01

    The device of the present invention can reliably prevent a possible erroneous withdrawal of control rod driving mechanism when the pressure of a coolant line is increased by isolation operation of hydraulic control units upon periodical inspection for a BWR type reactor. That is, a coolant line is connected to the downstream of a hydraulic supply device. The coolant line is connected to a hydraulic control unit. A coolant hydraulic detection device and a pressure setting device are disposed to the coolant line. A closing signal line and a returning signal line are disposed, which connect the hydraulic supply device and a flow rate control valve for the hydraulic setting device. In the device of the present invention, even if pressure of supplied coolants is elevated due to isolation of hydraulic control units, the elevation of the hydraulic pressure can be prevented. Accordingly, reliability upon periodical reactor inspection can be improved. Further, the facility is simplified and the installation to an existent facility is easy. (I.S.)

  9. Device for cutting protrusions

    Science.gov (United States)

    Bzorgi, Fariborz M [Knoxville, TN

    2011-07-05

    An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

  10. Recent progress in power electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Yasuhiko; Yatsuo, Tsutomu

    1987-02-01

    Recent progress and future trends of power semiconductor devices (especially with respect to motor speed control) were described. Conventional discrete devices such as thyristors, bipolar transistors, unipolar transistors and Bi-MOS devices were referenced to. Reference was also made to High Voltage ICs. There has been steady progress with each of these power devices in current carrying capability, voltage blocking capability and switching speed. The Bipolar-MOS integreated device and the High Voltage IC are particularly interesting because their abilities and performances are much enhanced by skillful combination with conventional discrete devices. However, no one device meets all the needs, and it will always be necessary to select the right device for a specific task. (11 figs, 35 refs)

  11. Magnetic sensor device

    NARCIS (Netherlands)

    2009-01-01

    The present invention provides a sensor device and a method for detg. the presence and/or amt. of target moieties in a sample fluid, the target moieties being labeled with magnetic or magnetizable objects. The sensor device comprises a magnetic field generating means adapted for applying a retention

  12. Firewood processing devices in Finland 2002

    International Nuclear Information System (INIS)

    Mutikainen, A.; Kaerhae, K.

    2002-01-01

    This Forestry Bulletin presents a review of the market situation for firewood processing devices in Finland during March 2002. The review is based on a questionnaire sent to device manufacturers. The firewood processing devices have traditionally been divided into three groups according to their functions: cross-cutting devices, splitting devices and cross-cutting and splitting devices. With a cross-cutting device the tree can be cross-cut only. Because it is easily possible to build the splitting function into a cross-cutting device, merely manufacturing a cross-cutting devices is rare. In all the splitting machines on the market, the splitting is carried out on a horizontally operated hydraulic cylinder pushing against a splitting blade. The types of cross-cutting blade mostly used in cross-cutting and splitting devices are circular i.e. circular saw blade, and chain saw. These devices are called firewood sawing machines. In firewood chopping machines that have a chopping blade, the wood is cross-cut using a spiral or guillotine blade. The splitting is done by a wedge blade or an axe blade. The firewood chopping machines can cross-cut and split stems up to a maximum of 20-22 cm in diameter. Circular blade firewood machines use either a cone screw or hydraulic cylinder and counter blade for splitting. They can handle wood of 20-30 cm thick in diameter. Machines using a chain saw can process stems of a maximum 30-45 cm thick in diameter. All firewood machines that work with a chain saw use a hydraulic cylinder and counter blade for splitting. According to the questionnaire responses, there were 14 (12 Finnish, one Norwegian and one Italian) manufacturers of firewood processing devices in the market. There were over 80 device models. There were only three cross-cutting devices, thirty splitting devices and forty cross-cutting splitting devices. The price range of the devices was 500-66,000 euros (including 22% VAT). According to the MTT Agrifood Research Finland

  13. Meniscal repair devices.

    Science.gov (United States)

    Barber, F A; Herbert, M A

    2000-09-01

    Meniscal repair devices not requiring accessory incisions are attractive. Many factors contribute to their clinical effectiveness including their biomechanical characteristics. This study compared several new meniscal repair devices with standard meniscal suture techniques. Using a porcine model, axis-of-insertion loads were applied to various meniscal sutures and repair devices. A single device or stitch was placed in a created meniscal tear and a load applied. Both loads and modes of failure were recorded. The load-to-failure data show stratification into 4 distinct statistical groups. Group A, 113 N for a double vertical stitch; group B, 80 N for a single vertical stitch; group C, 57 N for the BioStinger, 56 N for a horizontal mattress stitch, and 50 N for the T-Fix stitch; and group D, 33 N for the Meniscus Arrow (inserted by hand or gun), 32 N for the Clearfix screw, 31 N for the SDsorb staple, 30 N for the Mitek meniscal repair system, and 27 N for the Biomet staple. The failure mechanism varied. Sutures broke away from the knot. The Meniscus Arrow and BioStinger pulled through the inner rim with the crossbar intact. The Clearfix screw failed by multiple mechanisms, whereas 1 leg of the SDsorb staple always pulled out of the outer rim. The Mitek device usually failed by pullout from the inner rim. The Biomet staple always broke at the crosshead or just below it. Although the surgeon should be aware of the material properties of the repair technique chosen for a meniscal repair, this information is only an indication of device performance and may not correlate with clinical healing results.

  14. Characterization and Analysis of Whole Transcriptome of Giant Panda Spleens: Implying Critical Roles of Long Non-Coding RNAs in Immunity.

    Science.gov (United States)

    Peng, Rui; Liu, Yuliang; Cai, Zhigang; Shen, Fujun; Chen, Jiasong; Hou, Rong; Zou, Fangdong

    2018-01-01

    Giant pandas, an endangered species, are a powerful symbol of species conservation. Giant pandas may suffer from a variety of diseases. Owing to their highly specialized diet of bamboo, giant pandas are thought to have a relatively weak ability to resist diseases. The spleen is the largest organ in the lymphatic system. However, there is little known about giant panda spleen at a molecular level. Thus, clarifying the regulatory mechanisms of spleen could help us further understand the immune system of the giant panda as well as its conservation. The two giant panda spleens were from two male individuals, one newborn and one an adult, in a non-pathological condition. The whole transcriptomes of mRNA, lncRNA, miRNA, and circRNA in the two spleens were sequenced using the Illumina HiSeq platform. EBseq and IDEG6 were used to observe the differentially expressed genes (DEGs) between these two spleens. Gene Ontology and KEGG analyses were used to annotate the function of DEGs. Furthermore, networks between non-coding RNAs and protein-coding genes were constructed to investigate the relationship between non-coding RNAs and immune-associated genes. By comparative analysis of the whole transcriptomes of these two spleens, we found that one of the major roles of lncRNAs could be involved in the regulation of immune responses of giant panda spleens. In addition, our results also revealed that microRNAs and circRNAs may have evolved to regulate a large set of biological processes of giant panda spleens, and circRNAs may function as miRNA sponges. To our knowledge, this is the first report of lncRNAs and circRNAs in giant panda, which could be a useful resource for further giant panda research. Our study reveals the potential functional roles of miRNAs, lncRNAs, and circRNAs in giant panda spleen. © 2018 The Author(s). Published by S. Karger AG, Basel.

  15. UHE Cosmic Ray Observations Using the Cygnus Water - Array

    Science.gov (United States)

    Dion, Cynthia L.

    1995-01-01

    The CYGNUS water-Cerenkov array, consisting of five surface water-Cerenkov detectors, was built in the CYGNUS extensive air shower array at Los Alamos, New Mexico (latitude 36^circ N, longitude 107^circ W, altitude 2310 meters) to search for point sources of ultra-high energy particles (>1014 eV per particle) with the CYGNUS extensive air shower array. The water-Cerenkov detectors are used to improve the angular resolution of the extensive air shower array. This experiment searches for point sources of UHE gamma-radiation that may be of galactic or extra-galactic origin. The data set from December 1991 to January 1994 consists of data from both the water-Cerenkov array and the CYGNUS extensive air shower array. These data are combined, and the angular resolution of this combined data set is measured to be 0.34^circ+0.03 ^circ-0.04^circ. The measurement is made by observing the cosmic-ray shadowing of the Sun and the Moon. Using a subset of these data, three potential sources of UHE emission are studied: the Crab Pulsar, and the active galactic nuclei Markarian 421 and Markarian 501. A search is conducted for continuous emission from these three sources, and emission over shorter time scales. This experiment is particularly sensitive to emission over these shorter time scales. There is no evidence of UHE emission from these three sources over any time scales studied, and upper bounds to the flux of gamma radiation are determined. The flux upper limit for continuous emission from the Crab Pulsar is found to be 1.2times10^ {-13}/rm cm^2/s above 70 TeV. The flux upper limit for continuous emission from Markarian 421 is found to be 1.3times10^ {-13}/rm cm^2/s above 50 TeV. The flux upper limit for continuous emission from Markarian 501 is found to be 3.8times10^ {-13}/rm cm^2/s above 50 TeV.

  16. Characterization and Analysis of Whole Transcriptome of Giant Panda Spleens: Implying Critical Roles of Long Non-Coding RNAs in Immunity

    Directory of Open Access Journals (Sweden)

    Rui Peng

    2018-04-01

    Full Text Available Background/Aims: Giant pandas, an endangered species, are a powerful symbol of species conservation. Giant pandas may suffer from a variety of diseases. Owing to their highly specialized diet of bamboo, giant pandas are thought to have a relatively weak ability to resist diseases. The spleen is the largest organ in the lymphatic system. However, there is little known about giant panda spleen at a molecular level. Thus, clarifying the regulatory mechanisms of spleen could help us further understand the immune system of the giant panda as well as its conservation. Methods: The two giant panda spleens were from two male individuals, one newborn and one an adult, in a non-pathological condition. The whole transcriptomes of mRNA, lncRNA, miRNA, and circRNA in the two spleens were sequenced using the Illumina HiSeq platform. EBseq and IDEG6 were used to observe the differentially expressed genes (DEGs between these two spleens. Gene Ontology and KEGG analyses were used to annotate the function of DEGs. Furthermore, networks between non-coding RNAs and protein-coding genes were constructed to investigate the relationship between non-coding RNAs and immune-associated genes. Results: By comparative analysis of the whole transcriptomes of these two spleens, we found that one of the major roles of lncRNAs could be involved in the regulation of immune responses of giant panda spleens. In addition, our results also revealed that microRNAs and circRNAs may have evolved to regulate a large set of biological processes of giant panda spleens, and circRNAs may function as miRNA sponges. Conclusion: To our knowledge, this is the first report of lncRNAs and circRNAs in giant panda, which could be a useful resource for further giant panda research. Our study reveals the potential functional roles of miRNAs, lncRNAs, and circRNAs in giant panda spleen.

  17. Examination of Experimental Data for Irradiation - Creep in Nuclear Graphite

    Science.gov (United States)

    Mobasheran, Amir Sassan

    The objective of this dissertation was to establish credibility and confidence levels of the observed behavior of nuclear graphite in neutron irradiation environment. Available experimental data associated with the OC-series irradiation -induced creep experiments performed at the Oak Ridge National Laboratory (ORNL) were examined. Pre- and postirradiation measurement data were studied considering "linear" and "nonlinear" creep models. The nonlinear creep model considers the creep coefficient to vary with neutron fluence due to the densification of graphite with neutron irradiation. Within the range of neutron fluence involved (up to 0.53 times 10^{26} neutrons/m ^2, E > 50 KeV), both models were capable of explaining about 96% and 80% of the variation of the irradiation-induced creep strain with neutron fluence at temperatures of 600^circC and 900^circC, respectively. Temperature and reactor power data were analyzed to determine the best estimates for the actual irradiation temperatures. It was determined according to thermocouple readouts that the best estimate values for the irradiation temperatures were well within +/-10 ^circC of the design temperatures of 600^circC and 900 ^circC. The dependence of the secondary creep coefficients (for both linear and nonlinear models) on irradiation temperature was determined assuming that the variation of creep coefficient with temperature, in the temperature range studied, is reasonably linear. It was concluded that the variability in estimate of the creep coefficients is definitely not the results of temperature fluctuations in the experiment. The coefficients for the constitutive equation describing the overall growth of grade H-451 graphite were also studied. It was revealed that the modulus of elasticity and the shear modulus are not affected by creep and that the electrical resistivity is slightly (less than 5%) changed by creep. However, the coefficient of thermal expansion does change with creep. The consistency of

  18. Proton therapy device

    International Nuclear Information System (INIS)

    Tronc, D.

    1994-01-01

    The invention concerns a proton therapy device using a proton linear accelerator which produces a proton beam with high energies and intensities. The invention lies in actual fact that the proton beam which is produced by the linear accelerator is deflected from 270 deg in its plan by a deflecting magnetic device towards a patient support including a bed the longitudinal axis of which is parallel to the proton beam leaving the linear accelerator. The patient support and the deflecting device turn together around the proton beam axis while the bed stays in an horizontal position. The invention applies to radiotherapy. 6 refs., 5 figs

  19. 78 FR 79304 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-12-30

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 870 [Docket No. FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for...--CARDIOVASCULAR DEVICES 0 1. The authority citation for 21 CFR part 870 continues to read as follows: Authority...

  20. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 892 [Docket No. FDA-2008-N-0273] Medical Devices; Radiology Devices; Reclassification of Full- Field Digital... and Drugs, 21 CFR part 892 is amended as follows: PART 892--RADIOLOGY DEVICES 0 1. The authority...

  1. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min

    2017-01-01

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured

  2. 21 CFR 866.2580 - Gas-generating device.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2580 Gas-generating device. (a) Identification. A gas-generating device is a device intended for medical purposes that produces...

  3. 77 FR 18829 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  4. 76 FR 71983 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  5. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  6. Compound semiconductor device modelling

    CERN Document Server

    Miles, Robert

    1993-01-01

    Compound semiconductor devices form the foundation of solid-state microwave and optoelectronic technologies used in many modern communication systems. In common with their low frequency counterparts, these devices are often represented using equivalent circuit models, but it is often necessary to resort to physical models in order to gain insight into the detailed operation of compound semiconductor devices. Many of the earliest physical models were indeed developed to understand the 'unusual' phenomena which occur at high frequencies. Such was the case with the Gunn and IMPATI diodes, which led to an increased interest in using numerical simulation methods. Contemporary devices often have feature sizes so small that they no longer operate within the familiar traditional framework, and hot electron or even quantum­ mechanical models are required. The need for accurate and efficient models suitable for computer aided design has increased with the demand for a wider range of integrated devices for operation at...

  7. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  8. Fluid circulation control device

    International Nuclear Information System (INIS)

    Benard, Henri; Henocque, Jean.

    1982-01-01

    Horizontal fluid circulation control device, of the type having a pivoting flap. This device is intended for being fitted in the pipes of hydraulic installation, particularly in a bleed and venting system of a nuclear power station shifting radioactive or contaminated liquids. The characteristic of this device is the cut-out at the top of the flap to allow the air contained in the pipes to flow freely [fr

  9. 75 FR 61507 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-10-05

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...

  10. Sodium aerosol recovering device

    International Nuclear Information System (INIS)

    Fujimori, Koji; Ueda, Mitsuo; Tanaka, Kazuhisa.

    1997-01-01

    A main body of a recovering device is disposed in a sodium cooled reactor or a sodium cooled test device. Air containing sodium aerosol is sucked into the main body of the recovering device by a recycling fan and introduced to a multi-staged metal mesh filter portion. The air about against each of the metal mesh filters, and the sodium aerosol in the air is collected. The air having a reduced sodium aerosol concentration circulates passing through a recycling fan and pipelines to form a circulation air streams. Sodium aerosol deposited on each of the metal mesh filters is scraped off periodically by a scraper driving device to prevent clogging of each of the metal filters. (I.N.)

  11. 75 FR 57968 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-09-23

    ...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...

  12. 78 FR 21129 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-09

    ... radiofrequency band ranging between 13 megahertz to 27.12 megahertz and is intended for the treatment of medical...] Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices...

  13. 76 FR 55398 - Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of...

    Science.gov (United States)

    2011-09-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...

  14. A New Tool for Assessing Mobile Device Proficiency in Older Adults: The Mobile Device Proficiency Questionnaire.

    Science.gov (United States)

    Roque, Nelson A; Boot, Walter R

    2018-02-01

    Mobile device proficiency is increasingly required to participate in society. Unfortunately, there still exists a digital divide between younger and older adults, especially with respect to mobile devices (i.e., tablet computers and smartphones). Training is an important goal to ensure that older adults can reap the benefits of these devices. However, efficient/effective training depends on the ability to gauge current proficiency levels. We developed a new scale to accurately assess the mobile device proficiency of older adults: the Mobile Device Proficiency Questionnaire (MDPQ). We present and validate the MDPQ and a short 16-question version of the MDPQ (MDPQ-16). The MDPQ, its subscales, and the MDPQ-16 were found to be highly reliable and valid measures of mobile device proficiency in a large sample. We conclude that the MDPQ and MDPQ-16 may serve as useful tools for facilitating mobile device training of older adults and measuring mobile device proficiency for research purposes.

  15. Extraglottic airway devices: technology update

    Directory of Open Access Journals (Sweden)

    Sharma B

    2017-08-01

    Full Text Available Bimla Sharma, Chand Sahai, Jayashree Sood Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India Abstract: Extraglottic airway devices (EADs have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS formed the Airway Device Evaluation Project Team (ADEPT to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues. Keywords: extraglottic airway devices, laryngeal mask airway, other extraglottic airway devices, safety, technology update

  16. Biomedical devices and systems security.

    Science.gov (United States)

    Arney, David; Venkatasubramanian, Krishna K; Sokolsky, Oleg; Lee, Insup

    2011-01-01

    Medical devices have been changing in revolutionary ways in recent years. One is in their form-factor. Increasing miniaturization of medical devices has made them wearable, light-weight, and ubiquitous; they are available for continuous care and not restricted to clinical settings. Further, devices are increasingly becoming connected to external entities through both wired and wireless channels. These two developments have tremendous potential to make healthcare accessible to everyone and reduce costs. However, they also provide increased opportunity for technology savvy criminals to exploit them for fun and profit. Consequently, it is essential to consider medical device security issues. In this paper, we focused on the challenges involved in securing networked medical devices. We provide an overview of a generic networked medical device system model, a comprehensive attack and adversary model, and describe some of the challenges present in building security solutions to manage the attacks. Finally, we provide an overview of two areas of research that we believe will be crucial for making medical device system security solutions more viable in the long run: forensic data logging, and building security assurance cases.

  17. Uranium material removing and recovering device

    International Nuclear Information System (INIS)

    Takita, Shin-ichi.

    1997-01-01

    A uranium material removing and recovering device for use in removing surplus uranium heavy metal (UO 2 ) generated in a uranium handling facility comprises a uranium material removing device and a uranium material recovering device. The uranium material removing device comprises an adsorbing portion filled with a uranium adsorbent, a control portion for controlling the uranium adsorbent of the uranium adsorbing portion by a controlling agent, a uranium adsorbing device connected thereto and a jetting device for jetting the adsorbing liquid to equipments deposited with uranium. The recovering device comprises a recovering apparatus for recovering uranium materials deposited with the adsorbent liquid removed by the jetting device and a recovering tank for storing the recovered uranium materials. The device of the present invention can remove surplus uranium simply and safely, mitigate body's load upon removing and recovering operations, facilitate the processing for the exchange of the adsorbent and reduces the radioactive wastes. (T.M.)

  18. Deformable paper origami optoelectronic devices

    KAUST Repository

    He, Jr-Hau

    2017-01-19

    Deformable optoelectronic devices are provided, including photodetectors, photodiodes, and photovoltaic cells. The devices can be made on a variety of paper substrates, and can include a plurality of fold segments in the paper substrate creating a deformable pattern. Thin electrode layers and semiconductor nanowire layers can be attached to the substrate, creating the optoelectronic device. The devices can be highly deformable, e.g. capable of undergoing strains of 500% or more, bending angles of 25° or more, and/or twist angles of 270° or more. Methods of making the deformable optoelectronic devices and methods of using, e.g. as a photodetector, are also provided.

  19. Plasma devices for hydrocarbon reformation

    KAUST Repository

    Cha, Min Suk

    2017-02-16

    Plasma devices for hydrocarbon reformation are provided. Methods of using the devices for hydrocarbon reformation are also provided. The devices can include a liquid container to receive a hydrocarbon source, and a plasma torch configured to be submerged in the liquid. The plasma plume from the plasma torch can cause reformation of the hydrocarbon. The device can use a variety of plasma torches that can be arranged in a variety of positions in the liquid container. The devices can be used for the reformation of gaseous hydrocarbons and/or liquid hydrocarbons. The reformation can produce methane, lower hydrocarbons, higher hydrocarbons, hydrogen gas, water, carbon dioxide, carbon monoxide, or a combination thereof.

  20. [Innovation of characteristic medicinal cupping devices].

    Science.gov (United States)

    Li, Jianping; Zhang, Hui; Yang, Jianmei; Xu, Xinchun; Niu, Yanxia; Cai, Jun

    2015-08-01

    To compare the differences in the characteristic medicinal cupping therapy between the traditional cupping device and the innovated cupping device. Fifty patients of neck and low back pain were selected. The self-comparison was adopted. The cupping therapy was applied to the acupoints located on the left or right side with the traditional cupping device and the innovated cupping device. The cupping sites were centered at bilateral Quyuan (SI 13) and Dachangshu (BL 25). The cups were retained for 10 min. The traditional cupping device was the glass with smooth border, 100mL. The innovated cupping device was the vacuum-sucking cup. The operative time, medicinal leakage, comfort and cupping marks were observed for the two different cupping devices. The operative time with the innovated medicinal cupping device was shorter obviously compared with the traditional one at Quyuan (SI 13) and Dachangshu (BL 25, both Pcupping device was remarkably improved as compared with the traditional one at the two acupoints (both Pcupping operation (both P>0. 05). The cupping marks with the innovated medicinal cupping device were much deeper than those with the traditional one after cupping therapy. The innovated cupping device is more convenent and comfortable in operation during the characteristic medicinal cupping therapy.

  1. Methods of forming semiconductor devices and devices formed using such methods

    Science.gov (United States)

    Fox, Robert V; Rodriguez, Rene G; Pak, Joshua

    2013-05-21

    Single source precursors are subjected to carbon dioxide to form particles of material. The carbon dioxide may be in a supercritical state. Single source precursors also may be subjected to supercritical fluids other than supercritical carbon dioxide to form particles of material. The methods may be used to form nanoparticles. In some embodiments, the methods are used to form chalcopyrite materials. Devices such as, for example, semiconductor devices may be fabricated that include such particles. Methods of forming semiconductor devices include subjecting single source precursors to carbon dioxide to form particles of semiconductor material, and establishing electrical contact between the particles and an electrode.

  2. 21 CFR 872.1740 - Caries detection device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Caries detection device. 872.1740 Section 872.1740...) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1740 Caries detection device. (a) Identification. The caries detection device is a device intended to show the existence of decay in a patient's tooth...

  3. 76 FR 64223 - Cardiovascular Devices; Reclassification of External Pacemaker Pulse Generator Devices

    Science.gov (United States)

    2011-10-17

    ... Drug Administration 21 CFR Part 870 Cardiovascular Devices; Reclassification of External Pacemaker... Special Controls Guidance Document: External Pacemaker Pulse Generator; Availability; Proposed Rule and... [Docket No. FDA-2011-N-0650] Cardiovascular Devices; Reclassification of External Pacemaker Pulse...

  4. Mobile Device Encryption Systems

    OpenAIRE

    Teufl , Peter; Zefferer , Thomas; Stromberger , Christof

    2013-01-01

    Part 4: Software Security; International audience; The initially consumer oriented iOS and Android platforms, and the newly available Windows Phone 8 platform start to play an important role within business related areas. Within the business context, the devices are typically deployed via mobile device management (MDM) solutions, or within the bring-your-own-device (BYOD) context. In both scenarios, the security depends on many platform security functions, such as permission systems, manageme...

  5. Magnetic-bubble devices

    International Nuclear Information System (INIS)

    Fairholme, R.J.

    1978-01-01

    Magnetic bubbles were first described only ten years ago when research workers were discussing orthoferrites containing μm diameter bubbles. However, problems of material fabrication limit crystals to a few mm across which severely curtailed device development. Since then materials have changed and rare-earth-iron garnet films can be grown up 3 inches in diameter with bubble diameters down to sizes below 1 μm. The first commercial products have device capacities in the range 64 000 to 100 000 bits with bubble diameters between 4 and 6 μm. Chip capacities of 1 Mbit are presently under development in the laboratory, as are new techniques to use submicrometre bubbles. The operation and fabrication of a bubble device is described using the serial loop devices currently being manufactured at Plessey as models. Chip organization is one important variable which directly affects the access time. A range of access times and capacities is available which offers a wide range of market opportunities, ranging from consumer products to fixed head disc replacements. some of the application areas are described. (author)

  6. Underwater running device

    International Nuclear Information System (INIS)

    Kogure, Sumio; Matsuo, Takashiro; Yoshida, Yoji

    1996-01-01

    An underwater running device for an underwater inspection device for detecting inner surfaces of a reactor or a water vessel has an outer frame and an inner frame, and both of them are connected slidably by an air cylinder and connected rotatably by a shaft. The outer frame has four outer frame legs, and each of the outer frame legs is equipped with a sucker at the top end. The inner frame has four inner frame legs each equipped with a sucker at the top end. The outer frame legs and the inner frame legs are each connected with the outer frame and the inner frame by the air cylinder. The outer and the inner frame legs can be elevated or lowered (or extended or contracted) by the air cylinder. The sucker is connected with a jet pump-type negative pressure generator. The device can run and move by repeating attraction and releasing of the outer frame legs and the inner frame legs alternately while maintaining the posture of the inspection device stably. (I.N.)

  7. Neutron measuring device

    International Nuclear Information System (INIS)

    Hatayama, Akiyoshi; Seki, Eiji; Kita, Yoshio; Nishitani, Takeo.

    1993-01-01

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  8. Plant monitoring device

    International Nuclear Information System (INIS)

    Moriyama, Kunio.

    1991-01-01

    The monitoring device of the present invention is most suitable to early detection for equipment abnormality, or monitoring of state upon transient conditions such as startup and shutdown of an electric power plant, a large-scaled thermonuclear device and an accelerator plant. That is, in existent moitoring devices, acquired data are stored and the present operation states are monitored in comparison. A plant operation aquisition data reproduction section is disposed to the device. From the past operation conditions stored in the plant operation data aquisition reproducing section, the number of operation cycles that agrees with the present plant operation conditions is sought, to determine the agreed aquired data. Since these aquired data are time sequential data measured based on the standard time determined by the operation sequence, aquired data can be reproduced successively on every sample pitches. With such a constitution, aquired data under the same operation conditions as the present conditions are displayed together with the measured data. Accordingly, accurate monitoring can be conducted from the start-up to the shutdown of the plant. (I.S.)

  9. Criticality alarm device

    International Nuclear Information System (INIS)

    Kasai, Kenji.

    1994-01-01

    The device of the present invention is utilized, for example, to a reprocessing facility for storing and processing nuclear fuels and measures and controls the nuclear fuel assembly system so as not to exceed criticality. That is, a conventional criticality alarm device applies a predetermined processing to neutron fluxes generated from a nuclear fuel assembly system containing nuclear fuels and outputs an alarm. The device of the present invention comprises (1) a neutron flux supply source for increasing and decreasing neutron fluxes periodically and supplying them to nuclear fuel assemblies, (2) a detector for detecting neutron fluxes in the nuclear fuel assemblies, (3) a critical state judging section for judging the critical state of the nuclear fuel assemblies based on the periodically changing signals obtained from the detector (2) and (4) an alarm section for outputting criticality alarms depending on the result of the judgement. The device of the present invention can accurately recognize the critical state of the nuclear fuel assembly system and can forecast reaching of the nuclear fuel assembly to criticality or prompt neutron critical state. (I.S.)

  10. The IceCube Neutrino Observatory, the Pierre Auger Observatory and the Telescope Array: Joint Contribution to the 34th International Cosmic Ray Conference (ICRC 2015)

    Energy Technology Data Exchange (ETDEWEB)

    Aartsen, M.G.; et al.

    2015-11-06

    We have conducted three searches for correlations between ultra-high energy cosmic rays detected by the Telescope Array and the Pierre Auger Observatory, and high-energy neutrino candidate events from IceCube. Two cross-correlation analyses with UHECRs are done: one with 39 cascades from the IceCube `high-energy starting events' sample and the other with 16 high-energy `track events'. The angular separation between the arrival directions of neutrinos and UHECRs is scanned over. The same events are also used in a separate search using a maximum likelihood approach, after the neutrino arrival directions are stacked. To estimate the significance we assume UHECR magnetic deflections to be inversely proportional to their energy, with values $3^\\circ$, $6^\\circ$ and $9^\\circ$ at 100 EeV to allow for the uncertainties on the magnetic field strength and UHECR charge. A similar analysis is performed on stacked UHECR arrival directions and the IceCube sample of through-going muon track events which were optimized for neutrino point-source searches.

  11. Supernova pointing with low- and high-energy neutrino detectors

    CERN Document Server

    Tomás, R; Raffelt, Georg G; Kachelriess, M; Dighe, Amol S

    2003-01-01

    A future galactic SN can be located several hours before the optical explosion through the MeV-neutrino burst, exploiting the directionality of $nu$-$e$-scattering in a water Cherenkov detector such as Super-Kamiokande. We study the statistical efficiency of different methods for extracting the SN direction and identify a simple approach that is nearly optimal, yet independent of the exact SN neutrino spectra. We use this method to quantify the increase in the pointing accuracy by the addition of gadolinium to water, which tags neutrons from the inverse beta decay background. We also study the dependence of the pointing accuracy on neutrino mixing scenarios and initial spectra. We find that in the ``worst case'' scenario the pointing accuracy is $8^circ$ at 95% C.L. in the absence of tagging, which improves to $3^circ$ with a tagging efficiency of 95%. At a megaton detector, this accuracy can be as good as $0.6^circ$. A TeV-neutrino burst is also expected to be emitted contemporaneously with the SN optical ex...

  12. Impact of AlO x layer on resistive switching characteristics and device-to-device uniformity of bilayered HfO x -based resistive random access memory devices

    Science.gov (United States)

    Chuang, Kai-Chi; Chung, Hao-Tung; Chu, Chi-Yan; Luo, Jun-Dao; Li, Wei-Shuo; Li, Yi-Shao; Cheng, Huang-Chung

    2018-06-01

    An AlO x layer was deposited on HfO x , and bilayered dielectric films were found to confine the formation locations of conductive filaments (CFs) during the forming process and then improve device-to-device uniformity. In addition, the Ti interposing layer was also adopted to facilitate the formation of oxygen vacancies. As a result, the resistive random access memory (RRAM) device with TiN/Ti/AlO x (1 nm)/HfO x (6 nm)/TiN stack layers demonstrated excellent device-to-device uniformity although it achieved slightly larger resistive switching characteristics, which were forming voltage (V Forming) of 2.08 V, set voltage (V Set) of 1.96 V, and reset voltage (V Reset) of ‑1.02 V, than the device with TiN/Ti/HfO x (6 nm)/TiN stack layers. However, the device with a thicker 2-nm-thick AlO x layer showed worse uniformity than the 1-nm-thick one. It was attributed to the increased oxygen atomic percentage in the bilayered dielectric films of the 2-nm-thick one. The difference in oxygen content showed that there would be less oxygen vacancies to form CFs. Therefore, the random growth of CFs would become severe and the device-to-device uniformity would degrade.

  13. Network-Assisted Device-to-Device (D2D) Direct Proximity Discovery with Underlay Communication

    DEFF Research Database (Denmark)

    Pratas, Nuno; Popovski, Petar

    2015-01-01

    ) direct communication between proximate devices. While (ii) is treated extensively in the recent literature, (i) has received relatively little attention. In this paper we analyze a network-assisted underlay proximity discovery protocol, where a cellular device can take the role of: announcer (which......Device-to-Device communications are expected to play an important role in current and future cellular generations, by increasing the spatial reuse of spectrum resources and enabling lower latency communication links. This paradigm has two fundamental building blocks: (i) proximity discovery and (ii......, we consider the case where the announcers underlay their messages in the downlink transmissions that are directed towards the monitoring devices. We propose a power control scheme applied to the downlink transmission, which copes with the underlay transmission via additional power expenditure, while...

  14. CIRSE Vascular Closure Device Registry

    NARCIS (Netherlands)

    Reekers, Jim A.; Müller-Hülsbeck, Stefan; Libicher, Martin; Atar, Eli; Trentmann, Jens; Goffette, Pierre; Borggrefe, Jan; Zeleňák, Kamil; Hooijboer, Pieter; Belli, Anna-Maria

    2011-01-01

    Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. The CIRSE registry of closure devices

  15. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  16. Compressed optimization of device architectures

    Energy Technology Data Exchange (ETDEWEB)

    Frees, Adam [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Gamble, John King [Microsoft Research, Redmond, WA (United States). Quantum Architectures and Computation Group; Ward, Daniel Robert [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Center for Computing Research; Blume-Kohout, Robin J [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States). Center for Computing Research; Eriksson, M. A. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Friesen, Mark [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics; Coppersmith, Susan N. [Univ. of Wisconsin, Madison, WI (United States). Dept. of Physics

    2014-09-01

    Recent advances in nanotechnology have enabled researchers to control individual quantum mechanical objects with unprecedented accuracy, opening the door for both quantum and extreme- scale conventional computation applications. As these devices become more complex, designing for facility of control becomes a daunting and computationally infeasible task. Here, motivated by ideas from compressed sensing, we introduce a protocol for the Compressed Optimization of Device Architectures (CODA). It leads naturally to a metric for benchmarking and optimizing device designs, as well as an automatic device control protocol that reduces the operational complexity required to achieve a particular output. Because this protocol is both experimentally and computationally efficient, it is readily extensible to large systems. For this paper, we demonstrate both the bench- marking and device control protocol components of CODA through examples of realistic simulations of electrostatic quantum dot devices, which are currently being developed experimentally for quantum computation.

  17. Baking exhaustion device in thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Mitsunori.

    1987-02-02

    Purpose: To rapidly remove tritium and impurity from the vacuum region in the access port of the baking exhaustion device in a thermonuclear device. Constitution: Each of the gaps at the boundary between a fixed shielding member and a blanket module and at the boundary between the blanket and a divertor is made extremely small so as to minimize the neutron streaming from plasmas. Accordingly, in the case of evacuating the vacuum region in the access port, the gap conductance is extremely poor and the exhaustion speed is low. Then, baking pipeways for flowing high temperature fluids are embedded to the surface layer at the position facing to the vacuum region and the plasma evacuation duct and the vacuum region are connected with an evacuation duct of the access port. By flowing high temperature fluids in the pipeways and conducting evacuation, baking exhaustion can be carried out rapidly. (Kamimura, M.).

  18. Geometry and Cloaking Devices

    Science.gov (United States)

    Ochiai, T.; Nacher, J. C.

    2011-09-01

    Recently, the application of geometry and conformal mappings to artificial materials (metamaterials) has attracted the attention in various research communities. These materials, characterized by a unique man-made structure, have unusual optical properties, which materials found in nature do not exhibit. By applying the geometry and conformal mappings theory to metamaterial science, it may be possible to realize so-called "Harry Potter cloaking device". Although such a device is still in the science fiction realm, several works have shown that by using such metamaterials it may be possible to control the direction of the electromagnetic field at will. We could then make an object hidden inside of a cloaking device. Here, we will explain how to design invisibility device using differential geometry and conformal mappings.

  19. Nuclear reactor monitoring device

    International Nuclear Information System (INIS)

    Mihashi, Ishi; Honma, Hitoshi.

    1993-01-01

    The monitoring device of the present invention comprises a reactor core/reactor system data measuring and controlling device, a radioactivity concentration calculation device for activated coolants for calculating a radioactivity concentration of activated coolants in a main steam and reactor water by using an appropriate physical model, a radioactivity concentration correlation and comparison device for activated coolants for comparing correlationship with a radiation dose and an abnormality alarm device. Since radioactivity of activated primary coolants is monitored at each of positions in the reactor system and occurrence of leakage and the amount thereof from a primary circuit to a secondary circuit is monitored if the reactor has secondary circuit, integrity of the reactor system can be ensured and an abnormality can be detected rapidly. Further, radioactivity concentration of activated primary circuit coolants, represented by 16 N or 15 C, is always monitored at each of positions of PWR primary circuits. When a heat transfer pipe is ruptured in a steam generator, leakage of primary circuit coolants is detected rapidly, as well as the amount of the leakage can be informed. (N.H.)

  20. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  1. Encapsulation methods for organic electrical devices

    Science.gov (United States)

    Blum, Yigal D.; Chu, William Siu-Keung; MacQueen, David Brent; Shi, Yijian

    2013-06-18

    The disclosure provides methods and materials suitable for use as encapsulation barriers in electronic devices. In one embodiment, for example, there is provided an electroluminescent device or other electronic device encapsulated by alternating layers of a silicon-containing bonding material and a ceramic material. The encapsulation methods provide, for example, electronic devices with increased stability and shelf-life. The invention is useful, for example, in the field of microelectronic devices.

  2. Implantation damage in silicon devices

    International Nuclear Information System (INIS)

    Nicholas, K.H.

    1977-01-01

    Ion implantation, is an attractive technique for producing doped layers in silicon devices but the implantation process involves disruption of the lattice and defects are formed, which can degrade device properties. Methods of minimizing such damage are discussed and direct comparisons made between implantation and diffusion techniques in terms of defects in the final devices and the electrical performance of the devices. Defects are produced in the silicon lattice during implantation but they are annealed to form secondary defects even at room temperature. The annealing can be at a low temperature ( 0 C) when migration of defects in silicon in generally small, or at high temperature when they can grow well beyond the implanted region. The defect structures can be complicated by impurity atoms knocked into the silicon from surface layers by the implantation. Defects can also be produced within layers on top of the silicon and these can be very important in device fabrication. In addition to affecting the electrical properties of the final device, defects produced during fabrication may influence the chemical properties of the materials. The use of these properties to improve devices are discussed as well as the degradation they can cause. (author)

  3. An introduction to electrooptic devices

    CERN Document Server

    Kaminow, Ivan P

    1974-01-01

    An Introduction to Electrooptic Devices aims to present an introduction to the electrooptic effect and to summarize work on devices employing the electrooptic effect. The book provides the necessary background in classical crystal optics. The text then discusses topics including crystal symmetry, the tensor description of linear dielectric properties, propagation in anisotropic media, and passive crystal optic devices. The book also describes the phenomenological description of tensor nonlinear dielectric properties of crystals, with emphasis on the electrooptic effect; device design and appli

  4. Medical Devices; Obstetrical and Gynecological Devices; Classification of the Fetal Head Elevator. Final order.

    Science.gov (United States)

    2017-12-19

    The Food and Drug Administration (FDA or we) is classifying the fetal head elevator into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the fetal head elevator's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  5. A microfluidic device with pillars

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a microfluidic device for mixing liquid reagents, the device comprises, a chip forming at least one reaction chamber between a bottom and a top and extending between an inlet and an outlet. To enable manufacturing from less rigid materials, the device comprises pillars...

  6. 76 FR 44489 - Medical Devices; Neurological Devices; Classification of Repetitive Transcranial Magnetic...

    Science.gov (United States)

    2011-07-26

    ... is an external device that delivers transcranial repetitive pulsed magnetic fields of sufficient... premarket notification, prior to marketing the device, which contains information about the rTMS system they... significant effect on the human environment. Thus, neither an environmental assessment nor an environmental...

  7. Quality factor and dose equivalent investigations aboard the Soviet Space Station Mir

    Science.gov (United States)

    Bouisset, P.; Nguyen, V. D.; Parmentier, N.; Akatov, Ia. A.; Arkhangel'Skii, V. V.; Vorozhtsov, A. S.; Petrov, V. M.; Kovalev, E. E.; Siegrist, M.

    1992-07-01

    Since Dec 1988, date of the French-Soviet joint space mission 'ARAGATZ', the CIRCE device, had recorded dose equivalent and quality factor values inside the Mir station (380-410 km, 51.5 deg). After the initial gas filling two years ago, the low pressure tissue equivalent proportional counter is still in good working conditions. Some results of three periods are presented. The average dose equivalent rates measured are respectively 0.6, 0.8 and 0.6 mSv/day with a quality factor equal to 1.9. Some detailed measurements show the increasing of the dose equivalent rates through the SAA and near polar horns. The real time determination of the quality factors allows to point out high linear energy transfer events with quality factors in the range 10-20.

  8. Reactor water clean-up device

    International Nuclear Information System (INIS)

    Tanaka, Koji; Egashira, Yasuo; Shimada, Fumie; Igarashi, Noboru.

    1983-01-01

    Purpose: To save a low temperature reactor water clean-up system indispensable so far and significantly simplify the system by carrying out the reactor water clean-up solely in a high temperature reactor water clean-up system. Constitution: The reactor water clean-up device comprises a high temperature clean-up pump and a high temperature adsorption device for inorganic adsorbents. The high temperature adsorption device is filled with amphoteric ion adsorbing inorganic adsorbents, or amphoteric ion adsorbing inorganic adsorbents and anionic adsorbing inorganic adsorbents. The reactor water clean-up device introduces reactor water by the high temperature clean-up pump through a recycling system to the high temperature adsorption device for inorganic adsorbents. Since cations such as cobalt ions and anions such as chlorine ions in the reactor water are simultaneously removed in the device, a low temperature reactor water clean-up system which has been indispensable so far can be saved to realize the significant simplification for the entire system. (Seki, T.)

  9. Graphene nanoribbons for electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Geng, Zhansong; Granzner, Ralf; Kittler, Mario; Schwierz, Frank [FG Festkoerperelektronik, Institut fuer Mikro- und Nanoelektronik und Institut fuer Mikro- und Nanotechnologien MacroNano registered, Technische Universitaet Ilmenau (Germany); Haehnlein, Bernd; Auge, Manuel; Pezoldt, Joerg [FG Nanotechnologie, Institut fuer Mikro- und Nanoelektronik und Institut fuer Mikro- und Nanotechnologien MacroNano registered, Technische Universitaet Ilmenau (Germany); Lebedev, Alexander A. [National Research University of Information Technologies, Mechanics and Optics, St. Petersburg (Russian Federation); Division Solid State Electronics, Ioffe Institute, Sankt-Peterburg (Russian Federation); Davydov, Valery Y. [Division Solid State Electronics, Ioffe Institute, Sankt-Peterburg (Russian Federation)

    2017-11-15

    Graphene nanoribbons show unique properties and have attracted a lot of attention in the recent past. Intensive theoretical and experimental studies on such nanostructures at both the fundamental and application-oriented levels have been performed. The present paper discusses the suitability of graphene nanoribbons devices for nanoelectronics and focuses on three specific device types - graphene nanoribbon MOSFETs, side-gate transistors, and three terminal junctions. It is shown that, on the one hand, experimental devices of each type of the three nanoribbon-based structures have been reported, that promising performance of these devices has been demonstrated and/or predicted, and that in part they possess functionalities not attainable with conventional semiconductor devices. On the other hand, it is emphasized that - in spite of the remarkable progress achieved during the past 10 years - graphene nanoribbon devices still face a lot of problems and that their prospects for future applications remain unclear. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  10. Value-based procurement of medical devices: Application to devices for mechanical thrombectomy in ischemic stroke.

    Science.gov (United States)

    Trippoli, Sabrina; Caccese, Erminia; Marinai, Claudio; Messori, Andrea

    2018-03-01

    In the acute ischemic stroke, endovascular devices have shown promising clinical results and are also likely to represent value for money, as several modeling studies have shown. Pharmacoeconomic evaluations in this field, however, have little impact on the procurement of these devices. The present study explored how complex pharmacoeconomic models that evaluate effectiveness and cost can be incorporated into the in-hospital procurement of thrombectomy devices. As regards clinical modeling, we extracted outcomes at three months from randomized trials conducted for four thrombectomy devices, and we projected long-term results using standard Markov modeling. In estimating QALYs, the same model was run for the four devices. As regards economic modeling, we firstly estimated for each device the net monetary benefit (NMB) per patient (threshold = $60,000 per QALY); then, we simulated a competitive tender across the four products by determining the tender-based score (on a 0-to-100 scale). Prices of individual devices were obtained from manufacturers. Extensive sensitivity testing was applied to our analyses. For the four devices (Solitaire, Trevo, Penumbra, Solumbra), QALYs were 1.86, 1.52, 1,79, 1.35, NMB was $101,824, $83,546, $101,923, $69,440, and tender-based scores were 99.70, 43.43, 100, 0, respectively. Sensitivity analysis confirmed findings from base-case. Our results indicate that, in the field of thrombectomy devices, incorporating the typical tools of cost-effectiveness into the processes of tenders and procurement is feasible. Bridging the methodology of cost-effectiveness with the every-day practice of in-hospital procurement can contribute to maximizing the health returns that are generated by in-hospital expenditures for medical devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Fragment capture device

    Science.gov (United States)

    Payne, Lloyd R.; Cole, David L.

    2010-03-30

    A fragment capture device for use in explosive containment. The device comprises an assembly of at least two rows of bars positioned to eliminate line-of-sight trajectories between the generation point of fragments and a surrounding containment vessel or asset. The device comprises an array of at least two rows of bars, wherein each row is staggered with respect to the adjacent row, and wherein a lateral dimension of each bar and a relative position of each bar in combination provides blockage of a straight-line passage of a solid fragment through the adjacent rows of bars, wherein a generation point of the solid fragment is located within a cavity at least partially enclosed by the array of bars.

  12. Bolometric Device Based on Fluxoid Quantization

    Science.gov (United States)

    Bonetti, Joseph A.; Kenyon, Matthew E.; Leduc, Henry G.; Day, Peter K.

    2010-01-01

    The temperature dependence of fluxoid quantization in a superconducting loop. The sensitivity of the device is expected to surpass that of other superconducting- based bolometric devices, such as superconducting transition-edge sensors and superconducting nanowire devices. Just as important, the proposed device has advantages in sample fabrication.

  13. Fingerprinting 802.11 Devices

    National Research Council Canada - National Science Library

    Ellch, Jonathan P

    2006-01-01

    The research presented in this thesis provides the reader with a set of algorithms and techniques that enable the user to remotely determine what chipset and device driver an 802.11 device is using...

  14. Device Applications of Nonlinear Dynamics

    CERN Document Server

    Baglio, Salvatore

    2006-01-01

    This edited book is devoted specifically to the applications of complex nonlinear dynamic phenomena to real systems and device applications. While in the past decades there has been significant progress in the theory of nonlinear phenomena under an assortment of system boundary conditions and preparations, there exist comparatively few devices that actually take this rich behavior into account. "Device Applications of Nonlinear Dynamics" applies and exploits this knowledge to make devices which operate more efficiently and cheaply, while affording the promise of much better performance. Given the current explosion of ideas in areas as diverse as molecular motors, nonlinear filtering theory, noise-enhanced propagation, stochastic resonance and networked systems, the time is right to integrate the progress of complex systems research into real devices.

  15. Electronic Payments using Mobile Communication Devices

    NARCIS (Netherlands)

    Waaij, B.D. van der; Siljee, B.I.J.; Broekhuijsen, B.J.; Ponsioen, C.; Maas, A.; Aten, R.M.; Hoepman, J.H.; Loon, J.H. van; Smit, M.

    2009-01-01

    A method of making a payment uses a first mobile communication device (1) and a second mobile communication device (2), each mobile communication device being provided with a respective near field communication unit (11, 21) and at least one of the mobile communication devices being provided with an

  16. Nanoscale MOS devices: device parameter fluctuations and low-frequency noise (Invited Paper)

    Science.gov (United States)

    Wong, Hei; Iwai, Hiroshi; Liou, J. J.

    2005-05-01

    It is well-known in conventional MOS transistors that the low-frequency noise or flicker noise is mainly contributed by the trapping-detrapping events in the gate oxide and the mobility fluctuation in the surface channel. In nanoscale MOS transistors, the number of trapping-detrapping events becomes less important because of the large direct tunneling current through the ultrathin gate dielectric which reduces the probability of trapping-detrapping and the level of leakage current fluctuation. Other noise sources become more significant in nanoscale devices. The source and drain resistance noises have greater impact on the drain current noise. Significant contribution of the parasitic bipolar transistor noise in ultra-short channel and channel mobility fluctuation to the channel noise are observed. The channel mobility fluctuation in nanoscale devices could be due to the local composition fluctuation of the gate dielectric material which gives rise to the permittivity fluctuation along the channel and results in gigantic channel potential fluctuation. On the other hand, the statistical variations of the device parameters across the wafer would cause the noise measurements less accurate which will be a challenge for the applicability of analytical flicker noise model as a process or device evaluation tool for nanoscale devices. Some measures for circumventing these difficulties are proposed.

  17. Device independence for two-party cryptography and position verification with memoryless devices

    Science.gov (United States)

    Ribeiro, Jérémy; Thinh, Le Phuc; Kaniewski, Jedrzej; Helsen, Jonas; Wehner, Stephanie

    2018-06-01

    Quantum communication has demonstrated its usefulness for quantum cryptography far beyond quantum key distribution. One domain is two-party cryptography, whose goal is to allow two parties who may not trust each other to solve joint tasks. Another interesting application is position-based cryptography whose goal is to use the geographical location of an entity as its only identifying credential. Unfortunately, security of these protocols is not possible against an all powerful adversary. However, if we impose some realistic physical constraints on the adversary, there exist protocols for which security can be proven, but these so far relied on the knowledge of the quantum operations performed during the protocols. In this work we improve the device-independent security proofs of Kaniewski and Wehner [New J. Phys. 18, 055004 (2016), 10.1088/1367-2630/18/5/055004] for two-party cryptography (with memoryless devices) and we add a security proof for device-independent position verification (also memoryless devices) under different physical constraints on the adversary. We assess the quality of the devices by observing a Bell violation, and, as for Kaniewski and Wehner [New J. Phys. 18, 055004 (2016), 10.1088/1367-2630/18/5/055004], security can be attained for any violation of the Clauser-Holt-Shimony-Horne inequality.

  18. Location tracking forensics on mobile devices

    Science.gov (United States)

    Sack, Stefan; Kröger, Knut; Creutzburg, Reiner

    2013-03-01

    The spread of navigation devices has increased significantly over the last 10 years. With the help of the current development of even smaller navigation receiver units it is to navigate with almost any current smart phone. Modern navigation systems are no longer limited to satellite navigation, but use current techniques, e.g. WLAN localization. Due to the increased use of navigation devices their relevance to forensic investigations has risen rapidly. Because navigation, for example with navigation equipment and smartphones, have become common place these days, also the amount of saved navigation data has risen rapidly. All of these developments lead to a necessary forensic analysis of these devices. However, there are very few current procedures for investigating of navigation devices. Navigation data is forensically interesting because by the position of the devices in most cases the location and the traveled path of the owner can be reconstructed. In this work practices for forensic analysis of navigation devices are developed. Different devices will be analyzed and it is attempted, by means of forensic procedures to restore the traveled path of the mobile device. For analysis of the various devices different software and hardware is used. There will be presented common procedures for securing and testing of mobile devices. Further there will be represented the specials in the investigation of each device. The different classes considered are GPS handhelds, mobile navigation devices and smartphones. It will be attempted, wherever possible, to read all data of the device. The aim is to restore complete histories of the navigation data and to forensically study and analyze these data. This is realized by the usage of current forensic software e.g. TomTology or Oxygen Forensic Suite. It is also attempted to use free software whenever possible. Further alternative methods are used (e.g. rooting) to access locked data of the unit. To limit the practical work the

  19. 75 FR 47606 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of... General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee scheduled for August...

  20. Control rod selecting and driving device

    International Nuclear Information System (INIS)

    Isobe, Hideo.

    1981-01-01

    Purpose: To simultaneously drive a predetermined number of control rods in a predetermined mode by the control of addresses for predetermined number of control rods and read or write of driving codified data to and from the memory by way of a memory controller. Constitution: The system comprises a control rod information selection device for selecting predetermined control rods from a plurality of control rods disposed in a reactor and outputting information for driving them in a predetermined mode, a control rod information output device for codifying the information outputted from the above device and outputting the addresses to the predetermined control rods and driving mode coded data, and a driving device for driving said predetermined control rods in a predetermined mode in accordance with the codified data outputted from the above device, said control rod infromation output device comprising a memory device capable of storing a predetermined number of the codified data and a memory control device for storing the predetermined number of data into the above memory device at a predetermined timing while successively outputting the thus stored predetermined number of data at a predetermined timing. (Seki, T.)

  1. Providing Device Independence to Mobile Services

    OpenAIRE

    Nylander, Stina; Bylund, Markus

    2002-01-01

    People want user interfaces to services that are functional and well suited to the device they choose for access. To provide this, services must be able to offer device specific user interfaces for the wide range of devices available today. We propose to combine the two dominant approaches to platform independence, "Write Once, Run Every-where™" and "different version for each device", to create multiple device specific user interfaces for mobile services. This gives possibilities to minimize...

  2. Streamline-based microfluidic device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Kasdan, Harvey (Inventor)

    2013-01-01

    The present invention provides a streamline-based device and a method for using the device for continuous separation of particles including cells in biological fluids. The device includes a main microchannel and an array of side microchannels disposed on a substrate. The main microchannel has a plurality of stagnation points with a predetermined geometric design, for example, each of the stagnation points has a predetermined distance from the upstream edge of each of the side microchannels. The particles are separated and collected in the side microchannels.

  3. Physics of photonic devices

    CERN Document Server

    Chuang, Shun Lien

    2009-01-01

    The most up-to-date book available on the physics of photonic devices This new edition of Physics of Photonic Devices incorporates significant advancements in the field of photonics that have occurred since publication of the first edition (Physics of Optoelectronic Devices). New topics covered include a brief history of the invention of semiconductor lasers, the Lorentz dipole method and metal plasmas, matrix optics, surface plasma waveguides, optical ring resonators, integrated electroabsorption modulator-lasers, and solar cells. It also introduces exciting new fields of research such as:

  4. Nanoelectronic device applications handbook

    CERN Document Server

    Morris, James E

    2013-01-01

    Nanoelectronic Device Applications Handbook gives a comprehensive snapshot of the state of the art in nanodevices for nanoelectronics applications. Combining breadth and depth, the book includes 68 chapters on topics that range from nano-scaled complementary metal-oxide-semiconductor (CMOS) devices through recent developments in nano capacitors and AlGaAs/GaAs devices. The contributors are world-renowned experts from academia and industry from around the globe. The handbook explores current research into potentially disruptive technologies for a post-CMOS world.These include: Nanoscale advance

  5. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  6. Mobile device security for dummies

    CERN Document Server

    Campagna, Rich; Krishnan, Ashwin

    2011-01-01

    The information you need to avoid security threats on corporate mobile devices Mobile devices have essentially replaced computers for corporate users who are on the go and there are millions of networks that have little to no security. This essential guide walks you through the steps for securing a network and building a bulletproof framework that will protect and support mobile devices in the enterprise. Featuring real-world case scenarios, this straightforward guide shares invaluable advice for protecting mobile devices from the loss of sensitive and confidential corporate informati

  7. 78 FR 16684 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  8. 77 FR 20642 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  9. 76 FR 14415 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  10. 76 FR 62419 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-10-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  11. 75 FR 49940 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  12. 78 FR 30928 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  13. 76 FR 39882 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0478] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  14. A revised definition of high-level radioactive wastes unsuitable for dumping at sea

    International Nuclear Information System (INIS)

    Morley, F.

    1979-01-01

    The IAEA is responsible for defining these wastes, and makes recommendations to be used as a basis for the issue of special permits for the dumping at sea of those radioactive materials not defined as 'unsuitable'. Two IAEA information Circulars list in detail the Provisional (INF CIRC/205/Add. 1. Vienna, IAEA (January 1975)) and Revised (INF/ CIRC/205/Add. 1/Rev. 1. Vienna, IAEA (August 1978)) Definitions with annex material. These two definitions are set out for comparison purposes. The definitions were based on oceanographic and radiological evidence, and a summary is given of the procedures followed during their preparation. (U.K.)

  15. Impact of NaCl Contamination and Climatic Conditions on the Reliability of Printed Circuit Board Assemblies

    DEFF Research Database (Denmark)

    Verdingovas, Vadimas; Jellesen, Morten Stendahl; Ambat, Rajan

    2014-01-01

    The effect of climatic conditions and ionic contamination on the reliability of printed circuit board assembly has been investigated in terms of leakage current (LC) and electrochemical migration susceptibility. The change in LC as a function of relative humidity (RH) and temperature was measured...... and 15 $^{\\circ}\\hbox{C}$ –65 $^{\\circ}\\hbox{C}$. The variation of RH at the surface of the test specimens was imposed by 1) increasing the RH of the surrounding air and 2) reducing the temperature of the printed circuit boards using a cooling stage, while maintaining a constant climatic condition...

  16. Methodological aspects about the use of the radicarbon dating in historical time sites

    Directory of Open Access Journals (Sweden)

    Lubritto, Carmine

    2009-01-01

    Full Text Available In this paper basic concepts concerning radiocarbon dating and Accelerator Mass Spectrometry (AMS technique, and specifically the Centre for Isotopic Research on Cultural and Environmental heritage (CIRCE Laboratory AMS facility, will be given. Problem of contaminations in radiocarbon AMS measurements will be introduced, and the sample preparation laboratory and the graphitisation lines that are used at the CIRCE Laboratory will be presented. Moreover problems of sampling and interpretation of the archaeological radiocarbon dates will be treated in consideration of the nature of interdisciplinary research and of the impact of radiocarbon dating on archaeology.

  17. Devices for hearing loss

    Science.gov (United States)

    ... the sounds you want to hear. Assistive listening devices bring certain sounds directly to your ears. This can ... a small room or on a stage. Other devices can bring the sound from your TV, radio, or music ...

  18. Secure-Network-Coding-Based File Sharing via Device-to-Device Communication

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2017-01-01

    Full Text Available In order to increase the efficiency and security of file sharing in the next-generation networks, this paper proposes a large scale file sharing scheme based on secure network coding via device-to-device (D2D communication. In our scheme, when a user needs to share data with others in the same area, the source node and all the intermediate nodes need to perform secure network coding operation before forwarding the received data. This process continues until all the mobile devices in the networks successfully recover the original file. The experimental results show that secure network coding is very feasible and suitable for such file sharing. Moreover, the sharing efficiency and security outperform traditional replication-based sharing scheme.

  19. Device independent quantum key distribution secure against coherent attacks with memoryless measurement devices

    International Nuclear Information System (INIS)

    McKague, Matthew

    2009-01-01

    Device independent quantum key distribution (QKD) aims to provide a higher degree of security than traditional QKD schemes by reducing the number of assumptions that need to be made about the physical devices used. The previous proof of security by Pironio et al (2009 New J. Phys. 11 045021) applies only to collective attacks where the state is identical and independent and the measurement devices operate identically for each trial in the protocol. We extend this result to a more general class of attacks where the state is arbitrary and the measurement devices have no memory. We accomplish this by a reduction of arbitrary adversary strategies to qubit strategies and a proof of security for qubit strategies based on the previous proof by Pironio et al and techniques adapted from Renner.

  20. Mobile Device Usage in Higher Education

    Science.gov (United States)

    Delcker, Jan; Honal, Andrea; Ifenthaler, Dirk

    2016-01-01

    This paper focuses on mobile device usage of students in higher education. While more and more students embrace mobile devices in their daily life, institutions attempt to profit from those devices for educational purposes. It is therefore crucial for institutional development to identify students' needs and how mobile devices may facilitate these…

  1. Electrical device fabrication from nanotube formations

    Science.gov (United States)

    Nicholas, Nolan Walker; Kittrell, W. Carter; Kim, Myung Jong; Schmidt, Howard K.

    2013-03-12

    A method for forming nanotube electrical devices, arrays of nanotube electrical devices, and device structures and arrays of device structures formed by the methods. Various methods of the present invention allow creation of semiconducting and/or conducting devices from readily grown SWNT carpets rather than requiring the preparation of a patterned growth channel and takes advantage of the self-controlling nature of these carpet heights to ensure a known and controlled channel length for reliable electronic properties as compared to the prior methods.

  2. Loose part monitoring device

    International Nuclear Information System (INIS)

    Nomura, Hiroshi.

    1992-01-01

    The device of the present invention estimates a place where loose parts occur and structural components as the loose parts in a fluid flow channel of a reactor device, to provide information thereof to a plant operator. That is, the device of the present invention comprises (1) a plurality of detectors disposed to each of equipments constituting fluid channels, (2) an abnormal sound sensing device for sensing signals from the detectors, (3) an estimation section for estimating the place where the loose parts occur and the structural components thereof based on the signals sensed by the abnormal sound sensing section, (4) a memory section for storing data of the plant structure necessary for the estimation, and (5) a display section for displaying the result of the estimation. In such a device, the position where the loose parts collide against the plant structural component and the energy thereof are estimated. The dropping path of the loose parts is estimated from the estimation position. Parts to be loose parts in the path are listed up. The parts on the list is selected based on the estimated energy thereby enabling to determine the loose parts. (I.S.)

  3. Reactor container cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Koji; Kinoshita, Shoichiro

    1995-11-10

    The device of the present invention efficiently lowers pressure and temperature in a reactor container upon occurrence of a severe accident in a BWR-type reactor and can cool the inside of the container for a long period of time. That is, (1) pipelines on the side of an exhaustion tower of a filter portion in a filter bent device of the reactor container are in communication with pipelines on the side of a steam inlet of a static container cooling device by way of horizontal pipelines, (2) a back flow check valve is disposed to horizontal pipelines, (3) a steam discharge valve for a pressure vessel is disposed closer to the reactor container than the joint portion between the pipelines on the side of the steam inlet and the horizontal pipelines. Upon occurrence of a severe accident, when the pressure vessel should be ruptured and steams containing aerosol in the reactor core should be filled in the reactor container, the inlet valve of the static container cooling device is closed. Steams are flown into the filter bent device of the reactor container, where the aerosols can be removed. (I.S.).

  4. MRI-powered biomedical devices.

    Science.gov (United States)

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  5. Reactor noise monitoring device

    International Nuclear Information System (INIS)

    Yamanaka, Hiroto.

    1990-01-01

    The present invention concerns a reactor noise monitoring device by detecting abnormal sounds in background noises. Vibration sounds detected by accelerometers are applied to a loose parts detector. The detector generates high alarm if there are sudden impact sounds in the background noises and applies output signals to an accumulation device. If there is slight impact sounds in the vicinity of any of the accelerometers, the accumulation device accumulates the abnormal sounds assumed to be generated from an identical site while synchronizing the waveforms for all of the channels. Then, the device outputs signals in which the background noises are cancelled, as detection signals. Therefore, S/N ratio can be improved and the abnormal sounds contained in the background noises can be detected, to thereby improve the accuracy for estimating the position where the abnormal sounds are generated. (I.S.)

  6. Integrated Ultrasonic-Photonic Devices

    DEFF Research Database (Denmark)

    Barretto, Elaine Cristina Saraiva

    in channel waveguides and Mach-Zehnder interferometers. Numerical models are developed based on the finite element method, and applied to several scenarios, such as optimization of the geometrical parameters of waveguides, use of slow light in photonic crystal waveguides and use of Lamb waves in membranized......This thesis deals with the modeling, design, fabrication and characterization of integrated ultrasonic-photonic devices, with particular focus on the use of standard semiconductor materials such as GaAs and silicon. The devices are based on the use of guided acoustic waves to modulate the light...... investigated. Comparisons are made with the numerical and experimental results, and they validate the obtained response of the acoustic and photonic components of the device. Finally, a new design for an optical frequency shifter is proposed, posing several advantages over existing devices in terms of size...

  7. [Design of SCM inoculation device].

    Science.gov (United States)

    Qian, Mingli; Xie, Haiyuan

    2014-01-01

    The first step of bacilli culture is inoculation bacteria on culture medium. Designing a device to increase efficiency of inoculation is significative. The new device is controlled by SCM. The stepper motor can drive the culture medium rotating, accelerating, decelerating, overturn and suspending. The device is high practicability and efficient, let inoculation easy for operator.

  8. Spill-Detector-and-Shutoff Device

    Science.gov (United States)

    Jarvis, M. R.; Fulton, D. S.

    1985-01-01

    Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.

  9. Evolution of atherectomy devices.

    Science.gov (United States)

    Al Khoury, G; Chaer, R

    2011-08-01

    Percutaneous atherectomy provides an alternative approach to the endovascular treatment of peripheral atherosclerotic occlusive disease beyond angioplasty and stenting, and has the theoretical advantage of lesion debulking and minimizing barotrauma to the vessel wall. Atherectomy has evolved greatly during the last decade, with currently four FDA approved devices for the treatment of peripheral arterial disease. Several reports have focused on the initial technical success rates, and demonstrated the safety and short as well as mid-term efficacy of atherectomy devices. This article will review the evolution of current atherectomy devices and the associated literature.

  10. Fundamentals of semiconductor devices

    CERN Document Server

    Lindmayer, Joseph

    1965-01-01

    Semiconductor properties ; semiconductor junctions or diodes ; transistor fundamentals ; inhomogeneous impurity distributions, drift or graded-base transistors ; high-frequency properties of transistors ; band structure of semiconductors ; high current densities and mechanisms of carrier transport ; transistor transient response and recombination processes ; surfaces, field-effect transistors, and composite junctions ; additional semiconductor characteristics ; additional semiconductor devices and microcircuits ; more metal, insulator, and semiconductor combinations for devices ; four-pole parameters and configuration rotation ; four-poles of combined networks and devices ; equivalent circuits ; the error function and its properties ; Fermi-Dirac statistics ; useful physical constants.

  11. Electronic devices and circuits

    CERN Document Server

    Pridham, Gordon John

    1972-01-01

    Electronic Devices and Circuits, Volume 3 provides a comprehensive account on electronic devices and circuits and includes introductory network theory and physics. The physics of semiconductor devices is described, along with field effect transistors, small-signal equivalent circuits of bipolar transistors, and integrated circuits. Linear and non-linear circuits as well as logic circuits are also considered. This volume is comprised of 12 chapters and begins with an analysis of the use of Laplace transforms for analysis of filter networks, followed by a discussion on the physical properties of

  12. Compound semiconductor device physics

    CERN Document Server

    Tiwari, Sandip

    2013-01-01

    This book provides one of the most rigorous treatments of compound semiconductor device physics yet published. A complete understanding of modern devices requires a working knowledge of low-dimensional physics, the use of statistical methods, and the use of one-, two-, and three-dimensional analytical and numerical analysis techniques. With its systematic and detailed**discussion of these topics, this book is ideal for both the researcher and the student. Although the emphasis of this text is on compound semiconductor devices, many of the principles discussed will also be useful to those inter

  13. Multifunctional Energy Storage and Conversion Devices.

    Science.gov (United States)

    Huang, Yan; Zhu, Minshen; Huang, Yang; Pei, Zengxia; Li, Hongfei; Wang, Zifeng; Xue, Qi; Zhi, Chunyi

    2016-10-01

    Multifunctional energy storage and conversion devices that incorporate novel features and functions in intelligent and interactive modes, represent a radical advance in consumer products, such as wearable electronics, healthcare devices, artificial intelligence, electric vehicles, smart household, and space satellites, etc. Here, smart energy devices are defined to be energy devices that are responsive to changes in configurational integrity, voltage, mechanical deformation, light, and temperature, called self-healability, electrochromism, shape memory, photodetection, and thermal responsivity. Advisable materials, device designs, and performances are crucial for the development of energy electronics endowed with these smart functions. Integrating these smart functions in energy storage and conversion devices gives rise to great challenges from the viewpoint of both understanding the fundamental mechanisms and practical implementation. Current state-of-art examples of these smart multifunctional energy devices, pertinent to materials, fabrication strategies, and performances, are highlighted. In addition, current challenges and potential solutions from materials synthesis to device performances are discussed. Finally, some important directions in this fast developing field are considered to further expand their application. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Testing device for pipeline groups and control method for testing device

    International Nuclear Information System (INIS)

    Naito, Shinji; Kajiyama, Shigeru; Takahashi, Fuminobu; Tsuchida, Kenji; Tachibana, Yukio; Shigehiro, Katsuya; Mahara, Yoichi.

    1995-01-01

    The device of the present invention comprises a testing device main body disposed to a rail, a movable mechanism positioning from a reference point, a circumferential direction scanning mechanism, an axial direction scanning mechanism, a posture control mechanism, and a testing probe. Upon testing of pipelines, the detection device main body and auxiliary members are moved from a reference point previously set on a rail for numerical control toward pipelines to be tested in a state where the axial direction scanning mechanism and the testing probe are suspended in the axial direction. The testing is conducted by controlling the position of the testing probe in the axial direction of the pipeline by means of the axial direction scanning mechanism, and scanning the testing probe to the outer circumference of the pipeline along the circumferential track by way of the circumferential direction scanning mechanism. The device can be extremely reduced in the thickness, and can be moved with no interference with pipelines and other obstacles by remote operation even under such undesired condition as the pipelines being crowded, so that non-destructive testing can be conducted accurately. (N.H.)

  15. RF and dc desensitized electroexplosive device

    Science.gov (United States)

    Krainiak, John W.; Speaks, Paul D.; Cornett, Michael S.

    1989-07-01

    This patent application relates to electroexplosive devices (EEDs) such as detonators, blasting caps and squibs, in particular to a method and device for desensitizing EEDs to electromagnetic radiation and electrostatic charges with the added ability to desensitize the device to essentially dc currents. An insensitive electroexplosive device to electrically ignite explosive is disclosed. This device is inherently immune to radio frequency (RF) radiation, and also provides protection against dc or very low frequency RF induced by arcing. A central feature is use of zeners and capacitors to form a reactively balanced bridge circuit. When constructed in semiconductor form, as described in this application, the device is capable of incorporation in small caliber ordnance.

  16. Unconventional device concepts for polymer solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Veenstra, S.C.; Slooff, L.H.; Verhees, W.J.H.; Cobussen-Pool, E.M.; Lenzmann, F.O.; Kroon, J.M. [ECN Solar Energy, Petten (Netherlands); Sessolo, M.; Bolink, H.J. [Instituto de Ciencia Molecular, Universidad de Valencia, Valencia (Spain)

    2009-09-15

    The inclusion of metal-oxide layers in polymer solar cells enables the fabrication of a series of unconventional device architectures. These devices include: semi-transparent polymer solar cells, devices with inverted polarity, as well as devices with air stable electrodes. A proof-of-principle of these devices is presented. The anticipated benefits of these novel device structures over conventional polymer solar cells are discussed.

  17. Unconventional Quantum Computing Devices

    OpenAIRE

    Lloyd, Seth

    2000-01-01

    This paper investigates a variety of unconventional quantum computation devices, including fermionic quantum computers and computers that exploit nonlinear quantum mechanics. It is shown that unconventional quantum computing devices can in principle compute some quantities more rapidly than `conventional' quantum computers.

  18. Radiation effects in optoelectronic devices

    International Nuclear Information System (INIS)

    Barnes, C.E.

    1977-03-01

    A summary is given of studies on radiation effects in light-emitting diodes, laser diodes, detectors, optical isolators and optical fibers. It is shown that the study of radiation damage in these devices can provide valuable information concerning the nature of the devices themselves, as well as methods of hardening these devices for applications in radiation environments

  19. Digital device for synchronous storage

    International Nuclear Information System (INIS)

    Kobzar', Yu.M.; Kovtun, V.G.; Pashechko, N.I.

    1991-01-01

    Synchronous storage digital device for IR electron-photon emission spectrometer operating with analogue-to-digital converter F4223 or monocrystal converter K572PV1 is described. The device accomplished deduction of noise-background in each storage cycle. Summation and deduction operational time equals 90 ns, device output code discharge - 20, number of storages -2 23

  20. Social-Aware Relay Selection for Cooperative Multicast Device-to-Device Communications

    Directory of Open Access Journals (Sweden)

    Francesco Chiti

    2017-12-01

    Full Text Available The increasing use of social networks such as Facebook, Twitter, and Instagram to share photos, video streaming, and music among friends has generated a huge increase in the amount of data traffic over wireless networks. This social behavior has triggered new communication paradigms such as device-to-device (D2D and relaying communication schemes, which are both considered as strong drivers for the next fifth-generation (5G cellular systems. Recently, the social-aware layer and its relationship to and influence on the physical communications layer have gained great attention as emerging focus points. We focus here on the case of relaying communications to pursue the multicast data dissemination to a group of users forming a social community through a relay node, according to the extension of the D2D mode to the case of device-to-many devices. Moreover, in our case, the source selects the device to act as the relay among different users of the multicast group by taking into account both the propagation link conditions and the relay social-trust level with the constraint of minimizing the end-to-end content delivery delay. An optimization procedure is also proposed in order to achieve the best performance. Finally, numerical results are provided to highlight the advantages of considering the impact of social level on the end-to-end delivery delay in the integrated social–physical network in comparison with the classical relay-assisted multicast communications for which the relay social-trust level is not considered.

  1. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  2. Automatic liquid nitrogen feeding device

    International Nuclear Information System (INIS)

    Gillardeau, J.; Bona, F.; Dejachy, G.

    1963-01-01

    An automatic liquid nitrogen feeding device has been developed (and used) in the framework of corrosion tests realized with constantly renewed uranium hexafluoride. The issue was to feed liquid nitrogen to a large capacity metallic trap in order to condensate uranium hexafluoride at the exit of the corrosion chambers. After having studied various available devices, a feeding device has been specifically designed to be robust, secure and autonomous, as well as ensuring a high liquid nitrogen flowrate and a highly elevated feeding frequency. The device, made of standard material, has been used during 4000 hours without any problem [fr

  3. Detecting device of atomic probe

    International Nuclear Information System (INIS)

    Nikonenkov, N.V.

    1979-01-01

    Operation of an atomic-probe recording device is discussed in detail and its flowsheet is given. The basic elements of the atomic-probe recording device intented for microanalysis of metals and alloys in an atomic level are the storage oscillograph with a raster-sweep unit, a two-channel timer using frequency meters, a digital printer, and a control unit. The digital printer records information supplied by four digital devices (two frequency meters and two digital voltmeters) in a four-digit binary-decimal code. The described device provides simultaneous recording of two ions produced per one vaporation event

  4. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    Science.gov (United States)

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  5. Progress and Prospects in Stretchable Electroluminescent Devices

    Directory of Open Access Journals (Sweden)

    Wang Jiangxin

    2017-03-01

    Full Text Available Stretchable electroluminescent (EL devices are a new form of mechanically deformable electronics that are gaining increasing interests and believed to be one of the essential technologies for next generation lighting and display applications. Apart from the simple bending capability in flexible EL devices, the stretchable EL devices are required to withstand larger mechanical deformations and accommodate stretching strain beyond 10%. The excellent mechanical conformability in these devices enables their applications in rigorous mechanical conditions such as flexing, twisting, stretching, and folding.The stretchable EL devices can be conformably wrapped onto arbitrary curvilinear surface and respond seamlessly to the external or internal forces, leading to unprecedented applications that cannot be addressed with conventional technologies. For example, they are in demand for wide applications in biomedical-related devices or sensors and soft interactive display systems, including activating devices for photosensitive drug, imaging apparatus for internal tissues, electronic skins, interactive input and output devices, robotics, and volumetric displays. With increasingly stringent demand on the mechanical requirements, the fabrication of stretchable EL device is encountering many challenges that are difficult to resolve. In this review, recent progresses in the stretchable EL devices are covered with a focus on the approaches that are adopted to tackle materials and process challenges in stretchable EL devices and delineate the strategies in stretchable electronics. We first introduce the emission mechanisms that have been successfully demonstrated on stretchable EL devices. Limitations and advantages of the different mechanisms for stretchable EL devices are also discussed. Representative reports are reviewed based on different structural and material strategies. Unprecedented applications that have been enabled by the stretchable EL devices are

  6. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.; Buttner, Ulrich; Yi, Ying

    2016-01-01

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  7. Drug delivery device including electrolytic pump

    KAUST Repository

    Foulds, Ian G.

    2016-03-31

    Systems and methods are provided for a drug delivery device and use of the device for drug delivery. In various aspects, the drug delivery device combines a “solid drug in reservoir” (SDR) system with an electrolytic pump. In various aspects an improved electrolytic pump is provided including, in particular, an improved electrolytic pump for use with a drug delivery device, for example an implantable drug delivery device. A catalytic reformer can be incorporated in a periodically pulsed electrolytic pump to provide stable pumping performance and reduced actuation cycle.

  8. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  9. Projected phase-change memory devices.

    Science.gov (United States)

    Koelmans, Wabe W; Sebastian, Abu; Jonnalagadda, Vara Prasad; Krebs, Daniel; Dellmann, Laurent; Eleftheriou, Evangelos

    2015-09-03

    Nanoscale memory devices, whose resistance depends on the history of the electric signals applied, could become critical building blocks in new computing paradigms, such as brain-inspired computing and memcomputing. However, there are key challenges to overcome, such as the high programming power required, noise and resistance drift. Here, to address these, we present the concept of a projected memory device, whose distinguishing feature is that the physical mechanism of resistance storage is decoupled from the information-retrieval process. We designed and fabricated projected memory devices based on the phase-change storage mechanism and convincingly demonstrate the concept through detailed experimentation, supported by extensive modelling and finite-element simulations. The projected memory devices exhibit remarkably low drift and excellent noise performance. We also demonstrate active control and customization of the programming characteristics of the device that reliably realize a multitude of resistance states.

  10. 21 CFR 864.6100 - Bleeding time device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bleeding time device. 864.6100 Section 864.6100 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6100 Bleeding time device...

  11. Effects of bacteria on CdS thin films used in technological devices

    Science.gov (United States)

    Alpdoğan, S.; Adıgüzel, A. O.; Sahan, B.; Tunçer, M.; Metin Gubur, H.

    2017-04-01

    Cadmium sulfide (CdS) thin films were fabricated on glass substrates by the chemical bath deposition method at 70 {}^\\circ \\text{C} considering deposition times ranging from 2 h to 5 h. The optical band gaps of CdS thin films were found to be in the 2.42-2.37 eV range. CdS thin films had uniform spherical nano-size grains which had polycrystalline, hexagonal and cubic phases. The films had a characteristic electrical resistivity of the order of {{10}5} Ω \\text{cm} and n-type conductivity at room condition. CdS thin films were incubated in cultures of B.domonas aeruginosa and Staphylococcus aureus, which exist abundantly in the environment, and form biofilms. SEM images showed that S. aureus and K. pneumonia were detected significantly on the film surfaces with a few of P. aeruginosa and B. subtilis cells attached. CdS thin film surface exhibits relatively good resistance to the colonization of P. aeruginosa and B. subtilis. Optical results showed that the band gap of CdS thin films which interacted with the bacteria is 2.42 \\text{eV} . The crystal structure and electrical properties of CdS thin films were not affected by bacterial adhesion. The antimicrobial effect of CdS nanoparticles was different for different bacterial strains.

  12. Smoothing type buffer memory device

    International Nuclear Information System (INIS)

    Podorozhnyj, D.M.; Yashin, I.V.

    1990-01-01

    The layout of the micropower 4-bit smoothing type buffer memory device allowing one to record without counting the sequence of input randomly distributed pulses in multi-channel devices with serial poll, is given. The power spent by a memory cell for one binary digit recording is not greater than 0.15 mW, the device dead time is 10 mus

  13. 47 CFR 2.801 - Radiofrequency device defined.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Radiofrequency device defined. 2.801 Section 2... MATTERS; GENERAL RULES AND REGULATIONS Marketing of Radio-frequency Devices § 2.801 Radiofrequency device defined. As used in this part, a radiofrequency device is any device which in its operation is capable of...

  14. Medical devices; neurological devices; classification of the transcranial magnetic stimulator for headache. Final order.

    Science.gov (United States)

    2014-07-08

    The Food and Drug Administration (FDA) is classifying the transcranial magnetic stimulator for headache into class II (special controls). The special controls that will apply to the device are identified in this order, and will be part of the codified language for the transcranial magnetic stimulator for headache classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  15. Analysis and simulation of semiconductor devices

    CERN Document Server

    Selberherr, Siegfried

    1984-01-01

    The invention of semiconductor devices is a fairly recent one, considering classical time scales in human life. The bipolar transistor was announced in 1947, and the MOS transistor, in a practically usable manner, was demonstrated in 1960. From these beginnings the semiconductor device field has grown rapidly. The first integrated circuits, which contained just a few devices, became commercially available in the early 1960s. Immediately thereafter an evolution has taken place so that today, less than 25 years later, the manufacture of integrated circuits with over 400.000 devices per single chip is possible. Coincident with the growth in semiconductor device development, the literature concerning semiconductor device and technology issues has literally exploded. In the last decade about 50.000 papers have been published on these subjects. The advent of so called Very-Large-Scale-Integration (VLSI) has certainly revealed the need for a better understanding of basic device behavior. The miniaturization of the s...

  16. [Medical Devices Law for pain therapists].

    Science.gov (United States)

    Regner, M; Sabatowski, R

    2016-08-01

    Medical Devices Law is a relatively new legal system, which has replaced the Medical Devices Regulations still well-known in Germany. German Medical Devices Law is based on European directives, which are, in turn, incorporated into national law by the Medical Devices Act. The Medical Devices Act is a framework law and covers a number of regulations that address specific topics within Medical Devices Law. In turn, in individual regulations, reference is made to guidelines, recommendations, etc. from other sources that provide detailed technical information on specific topics. Medical Devices Law is a very complex legal system, which needs to be permanently observed due to constant updating and adjustment. In the current article, the design and the structure of the system will be described, but special emphasis will be laid on important problem areas that need to be considered when applying and operating medical products, in this case by pain therapists in particular.

  17. Medical Devices; Neurological Devices; Classification of the External Vagal Nerve Stimulator for Headache. Final order.

    Science.gov (United States)

    2017-12-27

    The Food and Drug Administration (FDA or we) is classifying the external vagal nerve stimulator for headache into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the external vagal nerve stimulator for headache's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  18. Processes for multi-layer devices utilizing layer transfer

    Science.gov (United States)

    Nielson, Gregory N; Sanchez, Carlos Anthony; Tauke-Pedretti, Anna; Kim, Bongsang; Cederberg, Jeffrey; Okandan, Murat; Cruz-Campa, Jose Luis; Resnick, Paul J

    2015-02-03

    A method includes forming a release layer over a donor substrate. A plurality of devices made of a first semiconductor material are formed over the release layer. A first dielectric layer is formed over the plurality of devices such that all exposed surfaces of the plurality of devices are covered by the first dielectric layer. The plurality of devices are chemically attached to a receiving device made of a second semiconductor material different than the first semiconductor material, the receiving device having a receiving substrate attached to a surface of the receiving device opposite the plurality of devices. The release layer is etched to release the donor substrate from the plurality of devices. A second dielectric layer is applied over the plurality of devices and the receiving device to mechanically attach the plurality of devices to the receiving device.

  19. Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device.

    Science.gov (United States)

    Gibelli, Daniele; Pucciarelli, Valentina; Cappella, Annalisa; Dolci, Claudia; Sforza, Chiarella

    2018-01-31

    Modern 3-dimensional (3D) image acquisition systems represent a crucial technologic development in facial anatomy because of their accuracy and precision. The recently introduced portable devices can improve facial databases by increasing the number of applications. In the present study, the VECTRA H1 portable stereophotogrammetric device was validated to verify its applicability to 3D facial analysis. Fifty volunteers underwent 4 facial scans using portable VECTRA H1 and static VECTRA M3 devices (2 for each instrument). Repeatability of linear, angular, surface area, and volume measurements was verified within the device and between devices using the Bland-Altman test and the calculation of absolute and relative technical errors of measurement (TEM and rTEM, respectively). In addition, the 2 scans obtained by the same device and the 2 scans obtained by different devices were registered and superimposed to calculate the root mean square (RMS; point-to-point) distance between the 2 surfaces. Most linear, angular, and surface area measurements had high repeatability in M3 versus M3, H1 versus H1, and M3 versus H1 comparisons (range, 82.2 to 98.7%; TEM range, 0.3 to 2.0 mm, 0.4° to 1.8°; rTEM range, 0.2 to 3.1%). In contrast, volumes and RMS distances showed evident differences in M3 versus M3 and H1 versus H1 comparisons and reached the maximum when scans from the 2 different devices were compared. The portable VECTRA H1 device proved reliable for assessing linear measurements, angles, and surface areas; conversely, the influence of involuntary facial movements on volumes and RMS distances was more important compared with the static device. Copyright © 2018 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  1. Operation training aid device

    International Nuclear Information System (INIS)

    Yoshimura, Sadanori.

    1994-01-01

    The device of the present invention evaluates the propriety of an operation which is conducted optionally by a trainee depending on the state of the plant, analyzes the cause of an operation error and aids the preparation of training policy and teaching materials based on the results of the evaluation and the analysis. Namely, an operation data collection device collects operation data for the plant operation conducted by the trainee and the state of the plant during the operation. Since an operation evaluation device evaluates the plant operation in a short period of time based on the evaluation criteria of an operation evaluation knowledge base, an operation error is never overlooked. Accordingly, uniform and highly reliable operation training at definite evaluation criteria can be obtained. In addition, an error-cause analyzing device and a training policy knowledge base analyze the cause of an error inherent to each of the trainee, and it is recorded systematically independently on every trainees. Since a training policy guide device retrieves and presents an operation error and a cause of the error, there can be prepared a training policy incorporating training with respect to the operation error that each of the trainee tends to commit. (I.S.)

  2. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  3. Microfluidic chip-capillary electrophoresis devices

    CERN Document Server

    Fung, Ying Sing; Du, Fuying; Guo, Wenpeng; Ma, Tongmei; Nie, Zhou; Sun, Hui; Wu, Ruige; Zhao, Wenfeng

    2015-01-01

    Capillary electrophoresis (CE) and microfluidic chip (MC) devices are relatively mature technologies, but this book demonstrates how they can be integrated into a single, revolutionary device that can provide on-site analysis of samples when laboratory services are unavailable. By introducing the combination of CE and MC technology, Microfluidic Chip-Capillary Electrophoresis Devices broadens the scope of chemical analysis, particularly in the biomedical, food, and environmental sciences. The book gives an overview of the development of MC and CE technology as well as technology that now allows for the fabrication of MC-CE devices. It describes the operating principles that make integration possible and illustrates some achievements already made by the application of MC-CE devices in hospitals, clinics, food safety, and environmental research. The authors envision further applications for private and public use once the proof-of-concept stage has been passed and obstacles to increased commercialization are ad...

  4. 77 FR 19534 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-04-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological Reagents; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; correction...

  5. 76 FR 21237 - Medical Devices; Obstetrical and Gynecological Devices; Classification of the Hemorrhoid...

    Science.gov (United States)

    2011-04-15

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... directs agencies to assess all costs and benefits of available regulatory alternatives and, when... economic, environmental, public health and safety, and other advantages; distributive impacts; and equity...

  6. Fibre Optic Communication Key Devices

    CERN Document Server

    Grote, Norbert

    2012-01-01

    The book gives an in-depth description of the key devices of current and next generation fibre optic communication networks. In particular, the book covers devices such as semiconductor lasers, optical amplifiers, modulators, wavelength filters, and detectors but the relevant properties of optical fibres as well. The presentations include the physical principles underlying the various devices, the technologies used for the realization of the different devices, typical performance characteristics and limitations, and development trends towards more advanced components are also illustrated. Thus the scope of the book spans relevant principles, state-of-the-art implementations, the status of current research and expected future components.

  7. 21 CFR 892.2040 - Medical image hardcopy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  8. Plant abnormality inspection device

    International Nuclear Information System (INIS)

    Takenaka, Toshio.

    1990-01-01

    The present invention concerns a plant abnormality inspection device for conducting remote or automatic patrolling inspection in a plant and, more particularly, relates to such a device as capable of detecting abnormal odors. That is, the device comprises a moving device for moving to a predetermined position in the plant, a plurality of gas sensors for different kind of gases to be inspected mounted thereon, a comparator for comparing the concentration of a gas detected by the gas sensor with the normal gas concentration at the predetermined position and a judging means for judging the absence or presence of abnormality depending on the combination of the result of the comparison and deliverying a signal if the state is abnormal. As a result, a slight amount of gas responsible to odors released upon abnormality of the plant can be detected by a plurality of gas sensors for different kinds gases to rapidly and easily find abnormal portions in the plant. (I.S.)

  9. Authenticated sensor interface device

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Jody Rustyn; Poland, Richard W.

    2018-05-01

    A system and method for the secure storage and transmission of data is provided. A data aggregate device can be configured to receive secure data from a data source, such as a sensor, and encrypt the secure data using a suitable encryption technique, such as a shared private key technique, a public key encryption technique, a Diffie-Hellman key exchange technique, or other suitable encryption technique. The encrypted secure data can be provided from the data aggregate device to different remote devices over a plurality of segregated or isolated data paths. Each of the isolated data paths can include an optoisolator that is configured to provide one-way transmission of the encrypted secure data from the data aggregate device over the isolated data path. External data can be received through a secure data filter which, by validating the external data, allows for key exchange and other various adjustments from an external source.

  10. Zero-Power Radio Device.

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    This report describes an unpowered radio receiver capable of detecting and responding to weak signals transmit ted from comparatively long distances . This radio receiver offers key advantages over a short range zero - power radio receiver previously described in SAND2004 - 4610, A Zero - Power Radio Receiver . The device described here can be fabricated as an integrated circuit for use in portable wireless devices, as a wake - up circuit, or a s a stand - alone receiver operating in conjunction with identification decoders or other electroni cs. It builds on key sub - components developed at Sandia National Laboratories over many years. It uses surface acoustic wave (SAW) filter technology. It uses custom component design to enable the efficient use of small aperture antennas. This device uses a key component, the pyroelectric demodulator , covered by Sandia owned U.S. Patent 7397301, Pyroelectric Demodulating Detector [1] . This device is also described in Sandia owned U.S. Patent 97266446, Zero Power Receiver [2].

  11. Three-terminal superconducting devices

    International Nuclear Information System (INIS)

    Gallagher, W.J.

    1985-01-01

    The transistor has a number of properties that make it so useful. The authors discuss these and the additional properties a transistor would need to have for high performance applications at temperatures where superconductivity could contribute advantages to system-level performance. These properties then serve as criteria by which to evaluate three-terminal devices that have been proposed for applications at superconducting temperatures. FETs can retain their transistor properties at low temperatures, but their power consumption is too large for high-speed, high-density cryogenic applications. They discuss in detail why demonstrated superconducting devices with three terminals -Josephson effect based devices, injection controlled weak links, and stacked tunnel junction devices such as the superconducting transistor proposed by K. Gray and the quiteron -- each fail to have true transistor-like properties. They conclude that the potentially very rewarding search for a transistor compatible with superconductivity in high performance applications must be in new directions

  12. Fabrication of integrated metallic MEMS devices

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Ravnkilde, Jan Tue; Hansen, Ole

    2002-01-01

    A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators are characteri......A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators...

  13. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  14. Flexible devices: from materials, architectures to applications

    Science.gov (United States)

    Zou, Mingzhi; Ma, Yue; Yuan, Xin; Hu, Yi; Liu, Jie; Jin, Zhong

    2018-01-01

    Flexible devices, such as flexible electronic devices and flexible energy storage devices, have attracted a significant amount of attention in recent years for their potential applications in modern human lives. The development of flexible devices is moving forward rapidly, as the innovation of methods and manufacturing processes has greatly encouraged the research of flexible devices. This review focuses on advanced materials, architecture designs and abundant applications of flexible devices, and discusses the problems and challenges in current situations of flexible devices. We summarize the discovery of novel materials and the design of new architectures for improving the performance of flexible devices. Finally, we introduce the applications of flexible devices as key components in real life. Project supported by the National Key R&D Program of China (Nos. 2017YFA0208200, 2016YFB0700600, 2015CB659300), the National Natural Science Foundation of China (Nos. 21403105, 21573108), and the Fundamental Research Funds for the Central Universities (No. 020514380107).

  15. An evaluation of sharp safety blood evacuation devices.

    Science.gov (United States)

    Ford, Joanna; Phillips, Peter

    This article describes an evaluation of three sharp safety blood evacuation devices in seven Welsh NHS boards and the Welsh Blood Service. Products consisted of two phlebotomy needles possessing safety shields and one phlebotomy device with wings, tubing and a retractable needle. The device companies provided the devices and appropriate training. Participating healthcare workers used the safety device instead of the conventional device to sample blood during the evaluation period and each type of device was evaluated in random order. Participants filled in a questionnaire for each type of device and then a further questionnaire comparing the two shielded evacuation needles with each other Results showed that responses to all three products were fairly positive, although each device was not liked by everyone who used it. When the two shielded evacuation devices were compared with each other, most users preferred the device with the shield positioned directly above the needle to the device with the shield at the side. However, in laboratory tests, the preferred device produced more fluid splatter than the other shielded device on activation.

  16. Wireless device connection problems and design solutions

    Science.gov (United States)

    Song, Ji-Won; Norman, Donald; Nam, Tek-Jin; Qin, Shengfeng

    2016-09-01

    Users, especially the non-expert users, commonly experience problems when connecting multiple devices with interoperability. While studies on multiple device connections are mostly concentrated on spontaneous device association techniques with a focus on security aspects, the research on user interaction for device connection is still limited. More research into understanding people is needed for designers to devise usable techniques. This research applies the Research-through-Design method and studies the non-expert users' interactions in establishing wireless connections between devices. The "Learning from Examples" concept is adopted to develop a study focus line by learning from the expert users' interaction with devices. This focus line is then used for guiding researchers to explore the non-expert users' difficulties at each stage of the focus line. Finally, the Research-through-Design approach is used to understand the users' difficulties, gain insights to design problems and suggest usable solutions. When connecting a device, the user is required to manage not only the device's functionality but also the interaction between devices. Based on learning from failures, an important insight is found that the existing design approach to improve single-device interaction issues, such as improvements to graphical user interfaces or computer guidance, cannot help users to handle problems between multiple devices. This study finally proposes a desirable user-device interaction in which images of two devices function together with a system image to provide the user with feedback on the status of the connection, which allows them to infer any required actions.

  17. High speed serdes devices and applications

    CERN Document Server

    Stauffer, David R; Sorna, Michael A; Dramstad, Kent; Ogilvie, Clarence Rosser; Amanullah, Mohammad; Rockrohr, James Donald

    2008-01-01

    Offers an understanding of the features and functions typically found on HSS devices. This book explains how these HSS devices are used in protocol applications and the analysis which must be performed to use such HSS devices.

  18. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    International Nuclear Information System (INIS)

    Elshurafa, Amro M; El-Masry, Ezz I

    2010-01-01

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch.

  19. 76 FR 36548 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-06-22

    ... information related to the humanitarian device exemption for the Berlin Heart EXCOR Pediatric Ventricular Assist Device (VAD) sponsored by Berlin Heart, Inc. The Berlin Heart EXCOR Pediatric VAD device is a..., please contact AnnMarie Williams, Conference Management Staff, at 301-796-5966, at least 7 days in...

  20. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  1. Performance of Installed Cooking Exhaust Devices

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Delp, William W.; Apte, Michael G.; Price, Philip N.

    2011-11-01

    The performance metrics of airflow, sound, and combustion product capture efficiency (CE) were measured for a convenience sample of fifteen cooking exhaust devices, as installed in residences. Results were analyzed to quantify the impact of various device- and installation-dependent parameters on CE. Measured maximum airflows were 70% or lower than values noted on product literature for 10 of the devices. Above-the-cooktop devices with flat bottom surfaces (no capture hood) – including exhaust fan/microwave combination appliances – were found to have much lower CE at similar flow rates, compared to devices with capture hoods. For almost all exhaust devices and especially for rear-mounted downdraft exhaust and microwaves, CE was substantially higher for back compared with front burner use. Flow rate, and the extent to which the exhaust device extends over the burners that are in use, also had a large effect on CE. A flow rate of 95 liters per second (200 cubic feet per minute) was necessary, but not sufficient, to attain capture efficiency in excess of 75% for the front burners. A-weighted sound levels in kitchens exceeded 57 dB when operating at the highest fan setting for all 14 devices evaluated for sound performance.

  2. Building Evacuation with Mobile Devices

    OpenAIRE

    Merkel, Sabrina

    2014-01-01

    The rapidly growing world population and increasingly dense settlements demand ever-larger and more complex buildings from today's engineers. In comparison to this technological progress, a building's equipment for emergency evacuation has been hardly developed further. This work presents a concept for a building evacuation system based on mobile devices. Furthermore, various algorithms for route planning with mobile devices and for indoor localization of mobile devices are addressed.

  3. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  4. Floating Oil-Spill Containment Device

    Science.gov (United States)

    Jones, Jack A.

    2012-01-01

    Previous oil containment booms have an open top that allows natural gas to escape, and have significant oil leakage due to wave action. Also, a subsea pyramid oil trap exists, but cannot move relative to moving oil plumes from deepsea oil leaks. The solution is to have large, moveable oil traps. One version floats on the sea surface and has a flexible tarp cover and a lower weighted skirt to completely entrap the floating oil and natural gas. The device must have at least three sides with boats pulling at each apex, and sonar or other system to track the slowly moving oil plume, so that the boats can properly locate the booms. The oil trap device must also have a means for removal of the oil and the natural gas. A second design version has a flexible pyramid cover that is attached by lines to ballast on the ocean floor. This is similar to fixed, metal pyramid oil capture devices in the Santa Barbara Channel off the coast of California. The ballast lines for the improved design, however, would have winches that can move the pyramid to always be located above the oil and gas plume. A third design is a combination of the first two. It uses a submerged pyramid to trap oil, but has no anchor and uses boats to locate the trap. It has ballast weights located along the bottom of the tarp and/or at the corners of the trap. The improved floating oil-spill containment device has a large floating boom and weighted skirt surrounding the oil and gas entrapment area. The device is triangular (or more than three sides) and has a flexible tarp cover with a raised gas vent area. Boats pull on the apex of the triangles to maintain tension and to allow the device to move to optimum locations to trap oil and gas. The gas is retrieved from a higher buoyant part of the tarp, and oil is retrieved from the floating oil layer contained in the device. These devices can be operated in relatively severe weather, since waves will break over the devices without causing oil leaking. Also, natural

  5. A monitoring device for pressurised-air-driven diaphragm-based artificial heart assist devices

    NARCIS (Netherlands)

    Hoeben, F.P.; Hoeben, F.P.; de Mul, F.F.M.; Stokkink, J.S.D.; Stokkink, H.S.D.; Koelink, M.H.; Koelink, M.H.; Greve, Jan

    1992-01-01

    A non-invasive device has been developed to monitor the diaphragm position and the blood flow in artificial heart assist devices equipped with a pressurised-air-driven diaphragm. Light scattering from the diaphragm is used as a mechanism for measuring. Information about the position of several

  6. Structure and application of galvanomagnetic devices

    CERN Document Server

    Weiss, H

    1969-01-01

    International Series of Monographs on Semiconductors, Volume 8: Structure and Application of Galvanomagnetic Devices focuses on the composition, reactions, transformations, and applications of galvanomagnetic devices. The book first ponders on basic physical concepts, design and fabrication of galvanomagnetic devices, and properties of galvanomagnetic devices. Discussions focus on changes in electrical properties on irradiation with high-energy particles, magnetoresistor field-plate, Hall generator, preparation of semiconductor films by vacuum deposition, structure of field-plate magnetoresist

  7. Testing the Isotropic Universe Using the Gamma-Ray Burst Data of Fermi/GBM

    Science.gov (United States)

    Řípa, Jakub; Shafieloo, Arman

    2017-12-01

    The sky distribution of gamma-ray bursts (GRBs) has been intensively studied by various groups for more than two decades. Most of these studies test the isotropy of GRBs based on their sky number density distribution. In this work, we propose an approach to test the isotropy of the universe through inspecting the isotropy of the properties of GRBs such as their duration, fluences, and peak fluxes at various energy bands and different timescales. We apply this method on the Fermi/Gamma-ray Burst Monitor (GBM) data sample containing 1591 GRBs. The most noticeable feature we found is near the Galactic coordinates l≈ 30^\\circ , b≈ 15^\\circ , and radius r≈ 20^\\circ {--}40^\\circ . The inferred probability for the occurrence of such an anisotropic signal (in a random isotropic sample) is derived to be less than a percent in some of the tests while the other tests give results consistent with isotropy. These are based on the comparison of the results from the real data with the randomly shuffled data samples. Considering the large number of statistics we used in this work (some of which are correlated with each other), we can anticipate that the detected feature could be a result of statistical fluctuations. Moreover, we noticed a considerably low number of GRBs in this particular patch, which might be due to some instrumentation or observational effects that can consequently affect our statistics through some systematics. Further investigation is highly desirable in order to clarify this result, e.g., utilizing a larger future Fermi/GBM data sample as well as data samples of other GRB missions and also looking for possible systematics.

  8. Spin-Orbit Misalignments of Three Jovian Planets via Doppler Tomography

    Science.gov (United States)

    Johnson, Marshall C.; Cochran, William D.; Addison, Brett C.; Tinney, Chris G.; Wright, Duncan J.

    2017-10-01

    We present measurements of the spin-orbit misalignments of the hot Jupiters HAT-P-41 b and WASP-79 b, and the aligned warm Jupiter Kepler-448 b. We obtain these measurements with Doppler tomography, where we spectroscopically resolve the line profile perturbation during the transit due to the Rossiter-McLaughlin effect. We analyze time series spectra obtained during portions of five transits of HAT-P-41 b, and find a value of the spin-orbit misalignment of λ =-{22.1}-6.0{+0.8^\\circ }. We reanalyze the radial velocity Rossiter-McLaughlin data on WASP-79 b obtained by Addison et al. using Doppler tomographic methodology. We measure λ =-{99.1}-3.9{+4.1^\\circ }, consistent with but more precise than the value found by Addison et al. For Kepler-448 b we perform a joint fit to the Kepler light curve, Doppler tomographic data, and a radial velocity data set from Lillo-Box et al. We find an approximately aligned orbit (λ =-{7.1}-2.8{+4.2^\\circ }), in agreement with the value found by Bourrier et al. Through analysis of the Kepler light curve we measure a stellar rotation period of {P}{rot}=1.27+/- 0.11 days, and use this to argue that the full three-dimensional spin-orbit misalignment is small, \\psi ˜ 0^\\circ . Based in part on observations obtained with the Hobby-Eberly Telescope, which is a joint project of the University of Texas at Austin, the Pennsylvania State University, Stanford University, Ludwig-Maximilians-Universität München, and Georg-August-Universität Göttingen.

  9. Quantitative Proteomics Reveals the Regulatory Networks of Circular RNA CDR1as in Hepatocellular Carcinoma Cells.

    Science.gov (United States)

    Yang, Xue; Xiong, Qian; Wu, Ying; Li, Siting; Ge, Feng

    2017-10-06

    Circular RNAs (circRNAs), a class of widespread endogenous RNAs, play crucial roles in diverse biological processes and are potential biomarkers in diverse human diseases and cancers. Cerebellar-degeneration-related protein 1 antisense RNA (CDR1as), an oncogenic circRNA, is involved in human tumorigenesis and is dysregulated in hepatocellular carcinoma (HCC). However, the molecular mechanisms underlying CDR1as functions in HCC remain unclear. Here we explored the functions of CDR1as and searched for CDR1as-regulated proteins in HCC cells. A quantitative proteomics strategy was employed to globally identify CDR1as-regulated proteins in HCC cells. In total, we identified 330 differentially expressed proteins (DEPs) upon enhanced CDR1as expression in HepG2 cells, indicating that they could be proteins regulated by CDR1as. Bioinformatic analysis revealed that many DEPs were involved in cell proliferation and the cell cycle. Further functional studies of epidermal growth factor receptor (EGFR) found that CDR1as exerts its effects on cell proliferation at least in part through the regulation of EGFR expression. We further confirmed that CDR1as could inhibit the expression of microRNA-7 (miR-7). EGFR is a validated target of miR-7; therefore, CDR1as may exert its function by regulating EGFR expression via targeting miR-7 in HCC cells. Taken together, we revealed novel functions and underlying mechanisms of CDR1as in HCC cells. This study serves as the first proteome-wide analysis of a circRNA-regulated protein in cells and provides a reliable and highly efficient method for globally identifying circRNA-regulated proteins.

  10. Introduction to Semiconductor Devices

    Science.gov (United States)

    Brennan, Kevin F.

    2005-03-01

    This volume offers a solid foundation for understanding the most important devices used in the hottest areas of electronic engineering today, from semiconductor fundamentals to state-of-the-art semiconductor devices in the telecommunications and computing industries. Kevin Brennan describes future approaches to computing hardware and RF power amplifiers, and explains how emerging trends and system demands of computing and telecommunications systems influence the choice, design and operation of semiconductor devices. In addition, he covers MODFETs and MOSFETs, short channel effects, and the challenges faced by continuing miniaturization. His book is both an excellent senior/graduate text and a valuable reference for practicing engineers and researchers.

  11. Wireless Communications Device Wakeup Method and System

    NARCIS (Netherlands)

    Drago, S.; Sebastiano, F.; Leenaerts, D.M.W.; Breems, L.J.

    2008-01-01

    Abstract of WO 2009044368 Disclosed are wakeable wireless communications devices, and methods for waking wireless communications devices, for use in a wireless network of such devices. The devices communicate during respectively-designated timeslots according to a communications protocol. The

  12. Compact disk error measurements

    Science.gov (United States)

    Howe, D.; Harriman, K.; Tehranchi, B.

    1993-01-01

    The objectives of this project are as follows: provide hardware and software that will perform simple, real-time, high resolution (single-byte) measurement of the error burst and good data gap statistics seen by a photoCD player read channel when recorded CD write-once discs of variable quality (i.e., condition) are being read; extend the above system to enable measurement of the hard decision (i.e., 1-bit error flags) and soft decision (i.e., 2-bit error flags) decoding information that is produced/used by the Cross Interleaved - Reed - Solomon - Code (CIRC) block decoder employed in the photoCD player read channel; construct a model that uses data obtained via the systems described above to produce meaningful estimates of output error rates (due to both uncorrected ECC words and misdecoded ECC words) when a CD disc having specific (measured) error statistics is read (completion date to be determined); and check the hypothesis that current adaptive CIRC block decoders are optimized for pressed (DAD/ROM) CD discs. If warranted, do a conceptual design of an adaptive CIRC decoder that is optimized for write-once CD discs.

  13. Adapting to climate change in the Mediterranean: Some questions and answers

    International Nuclear Information System (INIS)

    Bille, R.

    2008-01-01

    Circe (Climate change and impact research: the Mediterranean environment (www.circeproject. eu), an EC -funded 4-year research project, aims at developing for the first time a comprehensive assessment of climate change impacts in the Mediterranean area. CIRCE's rational does not take climate impacts as direct consequences of climate changes: the causal relationship is much more complex since a given climate change leads to very contrasted impacts according to existing policies as well as to socio-economic and political responses. This paper freely draws on some findings from CIRCE 's first stakeholders meeting, organised by IDDRI in October 2007. A high level, focused dialogue among a small group of selected participants, this meeting was articulated around two key questions: 1 - Business models, sector-wide transitions and socio-economic irreversibilities: is there room for manoeuvre? 2 - Succeeding where we failed: can the climate challenge be turned into an opportunity? These questions were examined with regard to three sectors (agriculture, energy and tourism) and two themes (ecosystems protection and urban and regional planning). Important cross-cutting issues for the Mediterranean such as water management, regional security, international migrations, etc., were dealt with in the discussions along the two days. (author)

  14. Predicting Peri-Device Leakage of Left Atrial Appendage Device Closure Using Novel Three-Dimensional Geometric CT Analysis.

    Science.gov (United States)

    Chung, Hyemoon; Jeon, Byunghwan; Chang, Hyuk-Jae; Han, Dongjin; Shim, Hackjoon; Cho, In Jeong; Shim, Chi Young; Hong, Geu-Ru; Kim, Jung-Sun; Jang, Yangsoo; Chung, Namsik

    2015-12-01

    After left atrial appendage (LAA) device closure, peri-device leakage into the LAA persists due to incomplete occlusion. We hypothesized that pre-procedural three-dimensional (3D) geometric analysis of the interatrial septum (IAS) and LAA orifice can predict this leakage. We investigated the predictive parameters of LAA device closure obtained from baseline cardiac computerized tomography (CT) using a novel 3D analysis system. We conducted a retrospective study of 22 patients who underwent LAA device closure. We defined peri-device leakage as the presence of a Doppler signal inside the LAA after device deployment (group 2, n = 5) compared with patients without peri-device leakage (group 1, n = 17). Conventional parameters were measured by cardiac CT. Angles θ and φ were defined between the IAS plane and the line, linking the LAA orifice center and foramen ovale. Group 2 exhibited significantly better left atrial (LA) function than group 1 (p = 0.031). Pre-procedural θ was also larger in this group (41.9° vs. 52.3°, p = 0.019). The LAA cauliflower-type morphology was more common in group 2. Overall, the patients' LA reserve significantly decreased after the procedure (21.7 mm(3) vs. 17.8 mm(3), p = 0.035). However, we observed no significant interval changes in pre- and post-procedural values of θ and φ in either group (all p > 0.05). Angles between the IAS and LAA orifice might be a novel anatomical parameter for predicting peri-device leakage after LAA device closure. In addition, 3D CT analysis of the LA and LAA orifice could be used to identify clinically favorable candidates for LAA device closure.

  15. Design of wheel-type walking-assist device

    International Nuclear Information System (INIS)

    Jung, Seung Ho; Kim, Seung Ho; Kim, Chang Hoi; Seo, Yong Chil; Jung, Kyung Min; Lee, Sung Uk

    2006-03-01

    In this research, a outdoor wheel-type walking-assist device is developed to help an elder having a poor muscular strength at legs for walking, sitting and standing up easily at outdoors, and also for going and downing stairs. In conceptually designing, the environments of an elder's activity, the size of an elder's body and a necessary function of helping an elder are considered. This device has 4 wheels for stability. When an elder walks in incline plane with the proposed device, a rear-wing is rotated to keep the supporting device horizontal, regardless of an angle of inclination. A height-controlling device, which can control the height of the supporting device for adjusting an elder's height, is varied vertically to help an elder to sit and stand-up easily. Moreover, a outdoor wheel-type walking-assist device is conceptually designed and is made. In order to design it, the preview research is investigated firstly. On the basis of the proposed walking-assist device, the outdoor walking-assist device is designed and made. The outdoor wheel-type walking-assist device can go and down stairs automatically. This device go up and down the stair of having maximum 20cm height and an angle of 25 degrees with maximum 4 sec/stairs speed, and move at flatland with 60cm/sec speed

  16. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    KAUST Repository

    Elshurafa, Amro M.

    2010-03-22

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch. © 2010 IOP Publishing Ltd.

  17. Flexural pivot device

    International Nuclear Information System (INIS)

    Flaherty, Robert.

    1986-01-01

    A flexural pivot device or rotational actuator comprises first and sceond tubular members connected by flexural members of shape-memory-alloy. These are curved in the austenitic phase at a first temperature and after cooling to the martensitic phase are flattened. On heating one of the flexural members, it bends causing relative rotation of the tubular members. Heating of another member can produce opposite rotation. Heating is electrical or by hot gas. The device may be used in a nuclear reactor. (author)

  18. 47 CFR 15.103 - Exempted devices.

    Science.gov (United States)

    2010-10-01

    ... any transportation vehicle including motor vehicles and aircraft. (b) A digital device used... digital device utilized exclusively in an appliance, e.g., microwave oven, dishwasher, clothes dryer, air conditioner (central or window), etc. (e) Specialized medical digital devices (generally used at the direction...

  19. S-Band POSIX Device Drivers for RTEMS

    Science.gov (United States)

    Lux, James P.; Lang, Minh; Peters, Kenneth J.; Taylor, Gregory H.

    2011-01-01

    This is a set of POSIX device driver level abstractions in the RTEMS RTOS (Real-Time Executive for Multiprocessor Systems real-time operating system) to SBand radio hardware devices that have been instantiated in an FPGA (field-programmable gate array). These include A/D (analog-to-digital) sample capture, D/A (digital-to-analog) sample playback, PLL (phase-locked-loop) tuning, and PWM (pulse-width-modulation)-controlled gain. This software interfaces to Sband radio hardware in an attached Xilinx Virtex-2 FPGA. It uses plug-and-play device discovery to map memory to device IDs. Instead of interacting with hardware devices directly, using direct-memory mapped access at the application level, this driver provides an application programming interface (API) offering that easily uses standard POSIX function calls. This simplifies application programming, enables portability, and offers an additional level of protection to the hardware. There are three separate device drivers included in this package: sband_device (ADC capture and DAC playback), pll_device (RF front end PLL tuning), and pwm_device (RF front end AGC control).

  20. Memory attacks on device-independent quantum cryptography.

    Science.gov (United States)

    Barrett, Jonathan; Colbeck, Roger; Kent, Adrian

    2013-01-04

    Device-independent quantum cryptographic schemes aim to guarantee security to users based only on the output statistics of any components used, and without the need to verify their internal functionality. Since this would protect users against untrustworthy or incompetent manufacturers, sabotage, or device degradation, this idea has excited much interest, and many device-independent schemes have been proposed. Here we identify a critical weakness of device-independent protocols that rely on public communication between secure laboratories. Untrusted devices may record their inputs and outputs and reveal information about them via publicly discussed outputs during later runs. Reusing devices thus compromises the security of a protocol and risks leaking secret data. Possible defenses include securely destroying or isolating used devices. However, these are costly and often impractical. We propose other more practical partial defenses as well as a new protocol structure for device-independent quantum key distribution that aims to achieve composable security in the case of two parties using a small number of devices to repeatedly share keys with each other (and no other party).

  1. CDC field mapping device - ''ROTOTRACK''

    International Nuclear Information System (INIS)

    Yamada, R.; Hawtree, J.; Kaczar, K.; Leverence, R.; McGuire, K.; Newman-Holmes, C.; Schmidt, E.E.; Shallenberger, J.

    1985-10-01

    A field mapping device for the magnet of the Collider Detector at Fermilab (CDF) was constructed. The device was used for extensive study of the CDF magnetic field distribution. The mechanical and electrical features of the device, as well as the data acquisition system and software, are described. The mechanical system was designed so that the errors on the position and angle of the probe were +-0.75 mm and +-1 mrad, respectively

  2. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  3. Progesterone-releasing devices for cattle estrus induction and synchronization: Device optimization to anticipate shorter treatment durations and new device developments.

    Science.gov (United States)

    de Graaff, W; Grimard, B

    2018-05-01

    Synchronization programs using progesterone-releasing intravaginal devices that allow for fixed time artificial insemination are still finding increasing application in bovine reproduction. This practice is useful for rationalizing livestock management because an increased number of cows can be inseminated in one session without the need for estrus detection. Although much of the innovation related to the design and development of intravaginal devices for use in cattle took place in the previous century, progress in understanding the physiology of the bovine estrous cycle resulted in shorter treatment durations, a trend which is still continuing. In this competitive market, with little functional differentiation between the existing devices, the shorter treatment duration prompted for optimization of the progesterone content in the device, as the cost of the drug significantly contributes to the price per unit. For CIDR ® a reduction of the progesterone content of about 30 per cent was realized. Price reduction remained an important target for further device development. Next to reduction of progesterone content, cheaper and easier to process materials like polyethylene vinyl acetate (EVA) copolymers have been explored to replace the commonly used silicone elastomers. The reengineering effort of CIDR ® demonstrated that knowledge of release kinetics and insight into gradual depletion patterns in the device is critical for optimization of drug content without compromising performance (blood levels). More recent publications related to the use of alternative polymers like EVA and polyisoprene (IP) indicated encouraging results regarding further reduction of progesterone content. The use of EVA seems most promising, because it is in principle a low-cost polymer available in many grades and this thermoplastic polymer can be processed easily by means of commonly used techniques like injection molding and extrusion. The use of thermoplastic polymers, however, requires

  4. Synaptic electronics: materials, devices and applications.

    Science.gov (United States)

    Kuzum, Duygu; Yu, Shimeng; Wong, H-S Philip

    2013-09-27

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented.

  5. Securing IoT Devices at CERN

    CERN Multimedia

    CERN. Geneva

    2018-01-01

    CERN has more than 1000 Internet of Things (IoT) devices, which are connected to the office network. We have been doing the research to find all vulnerable IoT devices in CERN and mitigated them. We are currently working on detecting IoT devices automatically and, moreover, identifying the manufacturer, model and the running firmware version. This will help the CERN Computer Security Team to spot vulnerable devices and to show the security risks associated with them.

  6. Synaptic electronics: materials, devices and applications

    International Nuclear Information System (INIS)

    Kuzum, Duygu; Yu, Shimeng; Philip Wong, H-S

    2013-01-01

    In this paper, the recent progress of synaptic electronics is reviewed. The basics of biological synaptic plasticity and learning are described. The material properties and electrical switching characteristics of a variety of synaptic devices are discussed, with a focus on the use of synaptic devices for neuromorphic or brain-inspired computing. Performance metrics desirable for large-scale implementations of synaptic devices are illustrated. A review of recent work on targeted computing applications with synaptic devices is presented. (topical review)

  7. Flaw detection device for plasma facing wall in thermonuclear device

    International Nuclear Information System (INIS)

    Doi, Akira.

    1996-01-01

    The present invention concerns plasma facing walls of a thermonuclear device and provides a device for detecting a thickness of amour tiles accurately and efficiently with no manual operation. Namely, the position of the plasma facing surface of the amour tile is measured using a structure to which the amour tiles are to be disposed as a reference. Also in a case of disposing new armor tiles, the position of the plasma facing surface of the armor tiles is measured to thereby measure the wearing amount of the amour tiles based on the difference between the reference and the measured value. If a measuring means capable of measuring a plurality of amour tiles at once is used efficiency of the measurement and the detection can be enhanced. Several ten thousands of amour tiles are disposed to the plasma facing wall in a large scaled thermonuclear device, and a plenty of time was required for the detection. However, the present invention can improve the accuracy for the measurement and detection and provide time and labors-saving. (I.S.)

  8. Optoelectronic Devices Advanced Simulation and Analysis

    CERN Document Server

    Piprek, Joachim

    2005-01-01

    Optoelectronic devices transform electrical signals into optical signals and vice versa by utilizing the sophisticated interaction of electrons and light within micro- and nano-scale semiconductor structures. Advanced software tools for design and analysis of such devices have been developed in recent years. However, the large variety of materials, devices, physical mechanisms, and modeling approaches often makes it difficult to select appropriate theoretical models or software packages. This book presents a review of devices and advanced simulation approaches written by leading researchers and software developers. It is intended for scientists and device engineers in optoelectronics, who are interested in using advanced software tools. Each chapter includes the theoretical background as well as practical simulation results that help to better understand internal device physics. The software packages used in the book are available to the public, on a commercial or noncommercial basis, so that the interested r...

  9. Microfabricated fuel heating value monitoring device

    Science.gov (United States)

    Robinson, Alex L [Albuquerque, NM; Manginell, Ronald P [Albuquerque, NM; Moorman, Matthew W [Albuquerque, NM

    2010-05-04

    A microfabricated fuel heating value monitoring device comprises a microfabricated gas chromatography column in combination with a catalytic microcalorimeter. The microcalorimeter can comprise a reference thermal conductivity sensor to provide diagnostics and surety. Using microfabrication techniques, the device can be manufactured in production quantities at a low per-unit cost. The microfabricated fuel heating value monitoring device enables continuous calorimetric determination of the heating value of natural gas with a 1 minute analysis time and 1.5 minute cycle time using air as a carrier gas. This device has applications in remote natural gas mining stations, pipeline switching and metering stations, turbine generators, and other industrial user sites. For gas pipelines, the device can improve gas quality during transfer and blending, and provide accurate financial accounting. For industrial end users, the device can provide continuous feedback of physical gas properties to improve combustion efficiency during use.

  10. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  11. Digital Device Architecture and the Safe Use of Flash Devices in Munitions

    Science.gov (United States)

    Katz, Richard B.; Flowers, David; Bergevin, Keith

    2017-01-01

    Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Digital devices of interest to designers include flash-based microcontrollers and field programmable gate arrays (FPGAs). Almost a decade ago, a study was undertaken to determine if flash-based microcontrollers could be safely used in fuzes and, if so, how should such devices be applied. The results were documented in the Technical Manual for the Use of Logic Devices in Safety Features. This paper will first review the Technical Manual and discuss the rationale behind the suggested architectures for microcontrollers and a brief review of the concern about data retention in flash cells. An architectural feature in the microcontroller under study will be discussed and its use will show how to screen for weak or failed cells during manufacture, storage, or immediately prior to use. As was done for microcontrollers a decade ago, architectures for a flash-based FPGA will be discussed, showing how it can be safely used in fuzes. Additionally, architectures for using non-volatile (including flash-based) storage will be discussed for SRAM-based FPGAs.

  12. Medical device software: defining key terms.

    Science.gov (United States)

    Pashkov, Vitalii; Gutorova, Nataliya; Harkusha, Andrii

    one of the areas of significant growth in medical devices has been the role of software - as an integral component of a medical device, as a standalone device and more recently as applications on mobile devices. The risk related to a malfunction of the standalone software used within healthcare is in itself not a criterion for its qualification or not as a medical device. It is therefore, necessary to clarify some criteria for the qualification of stand-alone software as medical devices Materials and methods: Ukrainian, European Union, United States of America legislation, Guidelines developed by European Commission and Food and Drug Administration's, recommendations represented by international voluntary group and scientific works. This article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. the legal regulation of software which is used for medical purpose in Ukraine limited to one definition. In European Union and United States of America were developed and applying special guidelines that help developers, manufactures and end users to difference software on types standing on medical purpose criteria. Software becomes more and more incorporated into medical devices. Developers and manufacturers may not have initially appreciated potential risks to patients and users such situation could have dangerous results for patients or users. It is necessary to develop and adopt the legislation that will intend to define the criteria for the qualification of medical device software and the application of the classification criteria to such software, provide some illustrative examples and step by step recommendations to qualify software as medical device.

  13. Influence of dissolved gas and temperature on the light yield of new liquid scintillators

    CERN Document Server

    Buontempo, S; Golovkin, S V; Martellotti, G; Medvedkov, A M; Penso, G; Soloviev, A S; Vasilchenko, V G

    1999-01-01

    Sixteen new liquid scintillators, emitting green light, were studied. They are based on four solvents combined with four dopants. The influence of different gas atmospheres was studied. In particular it was shown that by keeping these liquid scintillators in vacuum or in a neutral gas, the light yield increases up to 32~\\% at 20 $^{\\circ}$C and for the best solvent-dopant combinations. The dependance of the light yield on temperature was also studied for these scintillators. In the 20--60 $^{\\circ}$C interval, some exhibit a light yield variation of $\\sim$ 3 \\% which is smaller than that of the NE 102A plastic scintillator.

  14. Nanostructured transparent conducting oxide electrochromic device

    Science.gov (United States)

    Milliron, Delia; Tangirala, Ravisubhash; Llordes, Anna; Buonsanti, Raffaella; Garcia, Guillermo

    2016-05-17

    The embodiments described herein provide an electrochromic device. In an exemplary embodiment, the electrochromic device includes (1) a substrate and (2) a film supported by the substrate, where the film includes transparent conducting oxide (TCO) nanostructures. In a further embodiment, the electrochromic device further includes (a) an electrolyte, where the nanostructures are embedded in the electrolyte, resulting in an electrolyte, nanostructure mixture positioned above the substrate and (b) a counter electrode positioned above the mixture. In a further embodiment, the electrochromic device further includes a conductive coating deposited on the substrate between the substrate and the mixture. In a further embodiment, the electrochromic device further includes a second substrate positioned above the mixture.

  15. Steam cleaning device

    International Nuclear Information System (INIS)

    Karaki, Mikio; Muraoka, Shoichi.

    1985-01-01

    Purpose: To clean complicated and long objects to be cleaned having a structure like that of nuclear reactor fuel assembly. Constitution: Steams are blown from the bottom of a fuel assembly and soon condensated initially at the bottom of a vertical water tank due to water filled therein. Then, since water in the tank is warmed nearly to the saturation temperature, purified water is supplied from a injection device below to the injection device above the water tank on every device. In this way, since purified water is sprayed successively from below to above and steams are condensated in each of the places, the entire fuel assembly elongated in the vertical direction can be cleaned completely. Water in the reservoir goes upward like the steam flow and is drained together with the eliminated contaminations through an overflow pipe. After the cleaning has been completed, a main steam valve is closed and the drain valve is opened to drain water. (Kawakami, Y.)

  16. Photoelectric transfer device

    Energy Technology Data Exchange (ETDEWEB)

    Shinomiya, Takuji; Murao, Fumihide

    1987-12-07

    Concerning the conventional photoelectric transfer device, a short-circuit current of photodiodes is switched over with MOS transistors. However, since the backgate voltage of the MOS transistor which is to be used as the switching element, is provided by the source voltage, the leakage current between the backgate and the source/drain/ channel is great and due to this leakage current, errors occur in the photoelectric transfer power output. Especially, when the leakage current of the photodiodes is small, the error becomes large. In order to solve the above problem, this invention aims at offering a photoelectric transfer device which can provide the high precision photoelectric transfer even the short-circuit current generated in the photodiodes is small and proposes a photoelectric transfer device in which the backgate voltage of the MOS transistor switching over the short-circuit current of the photodiodes is made equal to the electric potential of the mutually connected anodes (or cathodes) of the photodiodes. (3 figs)

  17. Assistive Devices for Students with Disabilities.

    Science.gov (United States)

    Wisniewski, Lech; Sedlak, Robert

    1992-01-01

    Describes a variety of devices that can assist students with disabilities. Highlights recently developed devices for students with specific learning disabilities, and with vision, hearing, health, physical, and speech and language impairments. The devices can help rehabilitate, reeducate, facilitate normalcy, or augment current functioning. (GLR)

  18. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  19. Virtual Reality Interaction Using Mobile Devices

    KAUST Repository

    Aseeri, Sahar A.

    2013-07-01

    With the use of an immersive display system such as CAVE system, the user is able to realize a 3D immersive virtual environment realistically. However, interacting with virtual worlds in CAVE systems using traditional input devices to perform easy operations such as manipulation, object selection, and navigation is often difficult. This difficulty could diminish the immersion and sense of presence when it comes to 3D virtual environment tasks. Our research aims to implement and evaluate alternative approaches of interaction with immersive virtual environments on mobile devices for manipulation and object selection tasks. As many researchers have noted, using a mobile device as an interaction device has a number of advantages, including built-in display, built-in control, and touch screen facility. These advantages facilitate simple tasks within immersive virtual environments. This research proposes new methods using mobile devices like Smart-phones to perform di↵erent kinds of interactions both as an input device, (e.g. performing selection and manipulation of objects) and as an output device (e.g. utilizing the screen as an extra view for a virtual camera or information display). Moreover, we developed a prototype system to demonstrate and informally evaluate these methods. The research conclusion suggests using mobile devices as a 3D-controller. This will be a more intuitive approach to interact within the virtual environment.

  20. Standardization of splash device

    Science.gov (United States)

    Fernández Raga, María; Peters, Piet

    2017-04-01

    The erosion is a complex process that has been studied extensively by numerous researchers, requiring a prolongued time effort and a large economic investment. To be effective, the measurements of erosion should be precise, controlled and replicable, and to assure efectiveness, measurement devices of erosion should be properly designed, constructed, well calibrated and also they should be operated by a trained person (Stroosnijder, 2005). Because researchers try to improve old devices, the equipment is constantly being redesigned, making the measurements not comparable and furthermore, producing a lack of available standarized device. The lack of standardization of erosion equipment is more obvious in the case of the local splash erosion, where the nature of the process makes very difficult to isolate its effects. In this article we compare the results obtained from five of the most common splash erosion devices (selected from more than 16 different currently types), under the same rain conditions, with the objective of facilitate the standardization of the method that will be more easy to build, minimizing the error. A set of six splash devices were setted in well known positions under simulated rain, to measured the differences, among devices and the accuracy of the data recovered after 10 minutes of rainfall simulation under different intensities (from 60 to 130 mm/h). The rainfall simulator of Wageningen was used, using sand as splash erosion source. Differences in the infiltration were also measured, and a calibration of sizes and speeds of the raindrops was done using the photography method (Hamidreza-Sadeghi et al., 2013). The splash devices selected for this study were unbounded splash devices (like the funnel, the cup (Fernandez-Raga et al., 2010) and the splash flume (Jomaa et al., 2010)), and bounded devices that allow the calculation of splash rate, (like the new cup (Scholten et al., 2011) and the Morgan tray). The behaviour of different splash devices

  1. Operation control device under radiation exposure

    International Nuclear Information System (INIS)

    Kimura, Kiichi; Murakami, Toichi.

    1994-01-01

    The device of the present invention performs smooth progress of operation by remote control for a plurality of operations in periodical inspections in controlled areas of a nuclear power plant, thereby reducing the operator's exposure dose. Namely, the device monitors the progressing state of the operation by displaying the progress of operation on a CRT of a centralized control device present in a low dose area remote from an operation field through an ITV camera disposed in the vicinity of the operation field. Further, operation sequence and operation instruction procedures previously inputted in the device are indicated to the operation field through an operation instruction outputting device (field CRT) in accordance with the progress of the operation steps. On the other hand, the operation progress can be aided by inputting information from the operation field such as start or completion of the operation steps. Further, the device of the present invention can monitor the change of operation circumstances and exposure dose of operators based on the information from a radiation dose measuring device disposed in the operation circumstance and to individual operators. (I.S.)

  2. Silicon photonics fundamentals and devices

    CERN Document Server

    Deen, M Jamal

    2012-01-01

    The creation of affordable high speed optical communications using standard semiconductor manufacturing technology is a principal aim of silicon photonics research. This would involve replacing copper connections with optical fibres or waveguides, and electrons with photons. With applications such as telecommunications and information processing, light detection, spectroscopy, holography and robotics, silicon photonics has the potential to revolutionise electronic-only systems. Providing an overview of the physics, technology and device operation of photonic devices using exclusively silicon and related alloys, the book includes: * Basic Properties of Silicon * Quantum Wells, Wires, Dots and Superlattices * Absorption Processes in Semiconductors * Light Emitters in Silicon * Photodetectors , Photodiodes and Phototransistors * Raman Lasers including Raman Scattering * Guided Lightwaves * Planar Waveguide Devices * Fabrication Techniques and Material Systems Silicon Photonics: Fundamentals and Devices outlines ...

  3. Devices for collecting chemical compounds

    Science.gov (United States)

    Scott, Jill R; Groenewold, Gary S

    2013-12-24

    A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from a fixed surface so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

  4. Next-Generation Multifunctional Electrochromic Devices.

    Science.gov (United States)

    Cai, Guofa; Wang, Jiangxin; Lee, Pooi See

    2016-08-16

    The rational design and exploration of electrochromic devices will find a wide range of applications in smart windows for energy-efficient buildings, low-power displays, self-dimming rear mirrors for automobiles, electrochromic e-skins, and so on. Electrochromic devices generally consist of multilayer structures with transparent conductors, electrochromic films, ion conductors, and ion storage films. Synthetic strategies and new materials for electrochromic films and transparent conductors, comprehensive electrochemical kinetic analysis, and novel device design are areas of active study worldwide. These are believed to be the key factors that will help to significantly improve the electrochromic performance and extend their application areas. In this Account, we present our strategies to design and fabricate electrochromic devices with high performance and multifunctionality. We first describe the synthetic strategies, in which a porous tungsten oxide (WO3) film with nearly ideal optical modulation and fast switching was prepared by a pulsed electrochemical deposition method. Multiple strategies, such as sol-gel/inkjet printing methods, hydrothermal/inkjet printing methods, and a novel hybrid transparent conductor/electrochromic layer have been developed to prepare high-performance electrochromic films. We then summarize the recent advances in transparent conductors and ion conductor layers, which play critial roles in electrochromic devices. Benefiting from the developments of soft transparent conductive substrates, highly deformable electrochromic devices that are flexible, foldable, stretchable, and wearable have been achieved. These emerging devices have great potential in applications such as soft displays, electrochromic e-skins, deformable electrochromic films, and so on. We finally present a concept of multifunctional smart glass, which can change its color to dynamically adjust the daylight and solar heat input of the building or protect the users' privacy

  5. An Overview of Biofield Devices

    Science.gov (United States)

    Muehsam, David; Chevalier, Gaétan; Barsotti, Tiffany

    2015-01-01

    Advances in biophysics, biology, functional genomics, neuroscience, psychology, psychoneuroimmunology, and other fields suggest the existence of a subtle system of “biofield” interactions that organize biological processes from the subatomic, atomic, molecular, cellular, and organismic to the interpersonal and cosmic levels. Biofield interactions may bring about regulation of biochemical, cellular, and neurological processes through means related to electromagnetism, quantum fields, and perhaps other means of modulating biological activity and information flow. The biofield paradigm, in contrast to a reductionist, chemistry-centered viewpoint, emphasizes the informational content of biological processes; biofield interactions are thought to operate in part via low-energy or “subtle” processes such as weak, nonthermal electromagnetic fields (EMFs) or processes potentially related to consciousness and nonlocality. Biofield interactions may also operate through or be reflected in more well-understood informational processes found in electroencephalographic (EEG) and electrocardiographic (ECG) data. Recent advances have led to the development of a wide variety of therapeutic and diagnostic biofield devices, defined as physical instruments best understood from the viewpoint of a biofield paradigm. Here, we provide a broad overview of biofield devices, with emphasis on those devices for which solid, peer-reviewed evidence exists. A subset of these devices, such as those based upon EEG- and ECG-based heart rate variability, function via mechanisms that are well understood and are widely employed in clinical settings. Other device modalities, such a gas discharge visualization and biophoton emission, appear to operate through incompletely understood mechanisms and have unclear clinical significance. Device modes of operation include EMF-light, EMF-heat, EMF-nonthermal, electrical current, vibration and sound, physical and mechanical, intentionality and nonlocality

  6. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  7. SOR/72-43 Radiation Emitting Devices Regulations

    International Nuclear Information System (INIS)

    1972-01-01

    These Regulations of 10 February 1972, supplemented by SOR/77-895, lay down the classes of radiation emitting devices for the purposes of the Radiation Emitting Devices Act. They lay down their standards of design and construction and warning sign specifications and provide for the procedure to be followed by inspectors of such devices. The devices include inter alia extra-oral dental x-ray equipment, baggage inspection x-ray devices, laser scanners, television receivers. (NEA)

  8. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Seki, Eiji; Kobayashi, Yoshihiro.

    1989-01-01

    The present invention concerns a device of ionizing radioactive gases to be processed in gaseous nuclear fission products in nuclear fuel reprocessing plants, etc., and injecting them into metal substrates for storage. The device comprises a vessel for a tightly closed type outer electrode in which gases to be processed are introduced, an electrode disposed to the inside of the vessel and the target material, a high DC voltage power source for applying high voltage to the electrodes, etc. There are disposed a first electric discharging portion for preparting discharge plasma for ion injection of different electrode distance and a second electric discharging portion for causing stable discharge between the vessel and the electrode. The first electric discharging portion for the ion injection provides an electrode distance suitable to acceleration sputtering and the second electric discharging portion is used for stable discharge. Accordingly, if the gas pressure in the radioactive gas storage device is reduced by the external disturbance, etc., since the second electric discharging portion satisfies the electric discharging conditions, the device can continue electric discharge. (K.M.)

  9. 21 CFR 882.5940 - Electroconvulsive therapy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroconvulsive therapy device. 882.5940 Section 882.5940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Electroconvulsive therapy device. (a) Identification. An electroconvulsive therapy device is a device used for...

  10. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  11. Nonimaging radiant energy device

    Science.gov (United States)

    Winston, Roland; Ning, Xiaohui

    1993-01-01

    A nonimaging radiant energy device may include a hyperbolically shaped reflective element with a radiant energy inlet and a radiant energy outlet. A convex lens is provided at the radiant energy inlet and a concave lens is provided at the radiant energy outlet. Due to the provision of the lenses and the shape of the walls of the reflective element, the radiant energy incident at the radiant energy inlet within a predetermined angle of acceptance is emitted from the radiant energy outlet exclusively within an acute exit angle. In another embodiment, the radiant energy device may include two interconnected hyperbolically shaped reflective elements with a respective convex lens being provided at each aperture of the device.

  12. Design of the Circulation Improving Resuscitation Care (CIRC) Trial: a new state of the art design for out-of-hospital cardiac arrest research

    NARCIS (Netherlands)

    Lerner, E.B.; Persse, D.; Souders, C.M.; Sterz, F.; Malzer, R.; Lozano, M., Jr.; Westfall, M.; Brouwer, M.A.; Grunsven, P.M. van; Whitehead, A.; Olsen, J.A.; Herken, U.R.; Wik, L.

    2011-01-01

    PURPOSE: Mechanical chest compression devices, such as the AutoPulse((R)), have been developed to overcome problems associated with manual CPR (M-CPR). Animal and human studies have shown that AutoPulse CPR improves hemodynamic parameters over M-CPR. However, human studies conducted in the

  13. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  14. Medical Devices; Clinical Chemistry and Clinical Toxicology Devices; Classification of the Organophosphate Test System. Final order.

    Science.gov (United States)

    2017-10-18

    The Food and Drug Administration (FDA or we) is classifying the organophosphate test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the organophosphate test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  15. Medical Devices; Hematology and Pathology Devices; Classification of a Cervical Intraepithelial Neoplasia Test System. Final order.

    Science.gov (United States)

    2018-01-03

    The Food and Drug Administration (FDA or we) is classifying the cervical intraepithelial neoplasia (CIN) test system into class II (special controls). The special controls that apply to the device type are identified in this order and will be part of the codified language for the CIN test system's classification. We are taking this action because we have determined that classifying the device into class II (special controls) will provide a reasonable assurance of safety and effectiveness of the device. We believe this action will also enhance patients' access to beneficial innovative devices, in part by reducing regulatory burdens.

  16. Organic material reducing device in nuclear power plant

    International Nuclear Information System (INIS)

    Minakata, Noriyuki; Takada, Takao

    1998-01-01

    A total organic carbon (TOC) removing device is disposed between a filtration device and a desalting device or between a condensator and the desalting device disposed to a radioactive liquid waste processing facility or a condensate cleaning system of a BWR type nuclear reactor. Since the removing ratio of the TOC removing device is generally high if impurities are not contained, and ionic ingredients are formed after decomposition, TOC can be decomposed and removed more efficiently and removal in a short period of time can be expected by disposing the TOC device downstream of the filtration device or a condensator to be disposed instead of the filtration device and upstream of the desalting device. Then, further enhanced effect can be expected, if two series of the TOC removing line and the bypass line are disposed between the filtration device or the condensator and the desalting device so as to enable selection of processed liquids. (T.M.)

  17. 77 FR 65580 - Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers...

    Science.gov (United States)

    2012-10-29

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-856] Certain Wireless Communication Devices, Portable Music and Data Processing Devices, Computers, and Components Thereof AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that the U.S. International...

  18. Flexible spin-orbit torque devices

    Energy Technology Data Exchange (ETDEWEB)

    Lee, OukJae; You, Long; Jang, Jaewon; Subramanian, Vivek [Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California 94720 (United States); Salahuddin, Sayeef [Department of Electrical Engineering and Computer Sciences, University of California at Berkeley, Berkeley, California 94720 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States)

    2015-12-21

    We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10{sup 6} successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging.

  19. Flexible spin-orbit torque devices

    International Nuclear Information System (INIS)

    Lee, OukJae; You, Long; Jang, Jaewon; Subramanian, Vivek; Salahuddin, Sayeef

    2015-01-01

    We report on state-of-the-art spintronic devices synthesized and fabricated directly on a flexible organic substrate. Large perpendicular magnetic anisotropy was achieved in ultrathin ferromagnetic heterostructures of Pt/Co/MgO sputtered on a non-rigid plastic substrate at room temperature. Subsequently, a full magnetic reversal of the Co was observed by exploiting the spin orbit coupling in Pt that leads to a spin accumulation at the Pt/Co interface when an in-plane current is applied. Quasi-static measurements show the potential for operating these devices at nano-second speeds. Importantly, the behavior of the devices remained unchanged under varying bending conditions (up to a bending radius of ≈ ±20–30 mm). Furthermore, the devices showed robust operation even after application of 10 6 successive pulses, which is likely sufficient for many flexible applications. Thus, this work demonstrates the potential for integrating high performance spintronic devices on flexible substrates, which could lead to many applications ranging from flexible non-volatile magnetic memory to local magnetic resonance imaging

  20. 21 CFR 864.6400 - Hematocrit measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematocrit measuring device. 864.6400 Section 864.6400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6400 Hematocrit measuring...