WorldWideScience

Sample records for chip study protocol

  1. Protocol: methodology for chromatin immunoprecipitation (ChIP in Chlamydomonas reinhardtii

    Directory of Open Access Journals (Sweden)

    Strenkert Daniela

    2011-11-01

    Full Text Available Abstract We report on a detailed chromatin immunoprecipitation (ChIP protocol for the unicellular green alga Chlamydomonas reinhardtii. The protocol is suitable for the analysis of nucleosome occupancy, histone modifications and transcription factor binding sites at the level of mononucleosomes for targeted and genome-wide studies. We describe the optimization of conditions for crosslinking, chromatin fragmentation and antibody titer determination and provide recommendations and an example for the normalization of ChIP results as determined by real-time PCR.

  2. Design of a 1-chip IBM-3270 protocol handler

    NARCIS (Netherlands)

    Spaanenburg, L.

    1989-01-01

    The single-chip design of a 20MHz IBM-3270 coax protocol handler in a conventional 3 μ CMOS process-technology is discussed. The harmonious combination of CMOS circuit tricks and high-level design disciplines allows the 50k transistor design to be compiled and optimized into a 35 mm**2 chip in 4

  3. Developing an optimum protocol for thermoluminescence dosimetry with gr-200 chips using Taguchi method

    International Nuclear Information System (INIS)

    Sadeghi, Maryam; Faghihi, Reza; Sina, Sedigheh

    2017-01-01

    Thermoluminescence dosimetry (TLD) is a powerful technique with wide applications in personal, environmental and clinical dosimetry. The optimum annealing, storage and reading protocols are very effective in accuracy of TLD response. The purpose of this study is to obtain an optimum protocol for GR-200; LiF: Mg, Cu, P, by optimizing the effective parameters, to increase the reliability of the TLD response using Taguchi method. Taguchi method has been used in this study for optimization of annealing, storage and reading protocols of the TLDs. A number of 108 GR-200 chips were divided into 27 groups, each containing four chips. The TLDs were exposed to three different doses, and stored, annealed and read out by different procedures as suggested by Taguchi Method. By comparing the signal-to-noise ratios the optimum dosimetry procedure was obtained. According to the results, the optimum values for annealing temperature (de.C), Annealing Time (s), Annealing to Exposure time (d), Exposure to Readout time (d), Pre-heat Temperature (de.C), Pre-heat Time (s), Heating Rate (de.C/s), Maximum Temperature of Readout (de.C), readout time (s) and Storage Temperature (de.C) are 240, 90, 1, 2, 50, 0, 15, 240, 13 and -20, respectively. Using the optimum protocol, an efficient glow curve with low residual signals can be achieved. Using optimum protocol obtained by Taguchi method, the dosimetry can be effectively performed with great accuracy. (authors)

  4. On-chip COMA cache-coherence protocol for microgrids of microthreaded cores

    NARCIS (Netherlands)

    Zhang, L.; Jesshope, C.

    2008-01-01

    This paper describes an on-chip COMA cache coherency protocol to support the microthread model of concurrent program composition. The model gives a sound basis for building multi-core computers as it captures concurrency, abstracts communication and identifies resources, such as processor groups

  5. Developing an Optimum Protocol for Thermoluminescence Dosimetry with GR-200 Chips using Taguchi Method.

    Science.gov (United States)

    Sadeghi, Maryam; Faghihi, Reza; Sina, Sedigheh

    2017-06-15

    Thermoluminescence dosimetry (TLD) is a powerful technique with wide applications in personal, environmental and clinical dosimetry. The optimum annealing, storage and reading protocols are very effective in accuracy of TLD response. The purpose of this study is to obtain an optimum protocol for GR-200; LiF: Mg, Cu, P, by optimizing the effective parameters, to increase the reliability of the TLD response using Taguchi method. Taguchi method has been used in this study for optimization of annealing, storage and reading protocols of the TLDs. A number of 108 GR-200 chips were divided into 27 groups, each containing four chips. The TLDs were exposed to three different doses, and stored, annealed and read out by different procedures as suggested by Taguchi Method. By comparing the signal-to-noise ratios the optimum dosimetry procedure was obtained. According to the results, the optimum values for annealing temperature (°C), Annealing Time (s), Annealing to Exposure time (d), Exposure to Readout time (d), Pre-heat Temperature (°C), Pre-heat Time (s), Heating Rate (°C/s), Maximum Temperature of Readout (°C), readout time (s) and Storage Temperature (°C) are 240, 90, 1, 2, 50, 0, 15, 240, 13 and -20, respectively. Using the optimum protocol, an efficient glow curve with low residual signals can be achieved. Using optimum protocol obtained by Taguchi method, the dosimetry can be effectively performed with great accuracy. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. An optimized protocol for isolating primary epithelial cell chromatin for ChIP.

    Directory of Open Access Journals (Sweden)

    James A Browne

    Full Text Available A critical part of generating robust chromatin immunoprecipitation (ChIP data is the optimization of chromatin purification and size selection. This is particularly important when ChIP is combined with next-generation sequencing (ChIP-seq to identify targets of DNA-binding proteins, genome-wide. Current protocols refined by the ENCODE consortium generally use a two-step cell lysis procedure that is applicable to a wide variety of cell types. However, the isolation and size selection of chromatin from primary human epithelial cells may often be particularly challenging. These cells tend to form sheets of formaldehyde cross-linked material in which cells are resistant to membrane lysis, nuclei are not released and subsequent sonication produces extensive high molecular weight contamination. Here we describe an optimized protocol to prepare high quality ChIP-grade chromatin from primary human bronchial epithelial cells. The ENCODE protocol was used as a starting point to which we added the following key steps to separate the sheets of formaldehyde-fixed cells prior to lysis. (1 Incubation of the formaldehyde-fixed adherent cells in Trypsin-EDTA (0.25% room temperature for no longer than 5 min. (2 Equilibration of the fixed cells in detergent-free lysis buffers prior to each lysis step. (3 The addition of 0.5% Triton X-100 to the complete cell membrane lysis buffer. (4 Passing the cell suspension (in complete cell membrane lysis buffer through a 25-gauge needle followed by continuous agitation on ice for 35 min. Each step of the modified protocol was documented by light microscopy using the Methyl Green-Pyronin dual dye, which stains cytoplasm red (Pyronin and the nuclei grey-blue (Methyl green. This modified method is reproducibly effective at producing high quality sheared chromatin for ChIP and is equally applicable to other epithelial cell types.

  7. Introduction to Open Core Protocol Fastpath to System-on-Chip Design

    CERN Document Server

    Schwaderer, W David

    2012-01-01

    This book introduces Open Core Protocol (OCP), not as a conventional hardware communications protocol but as a meta-protocol: a means for describing and capturing the communications requirements of an IP core, and mapping them to a specific set of signals with known semantics.  Readers will learn the capabilities of OCP as a semiconductor hardware interface specification that allows different System-On-Chip (SoC) cores to communicate.  The OCP methodology presented enables intellectual property designers to design core interfaces in standard ways. This facilitates reusing OCP-compliant cores across multiple SoC designs which, in turn, drastically reduces design times, support costs, and overall cost for electronics/SoCs. Provides a comprehensive introduction to Open Core Protocol, which is more accessible than the full specification; Designed as a hands-on, how-to guide to semiconductor design; Includes numerous, real “usage examples” which are not available in the full specification; Integrates coverag...

  8. IFSA: a microfluidic chip-platform for frit-based immunoassay protocols

    Science.gov (United States)

    Hlawatsch, Nadine; Bangert, Michael; Miethe, Peter; Becker, Holger; Gärtner, Claudia

    2013-03-01

    Point-of-care diagnostics (POC) is one of the key application fields for lab-on-a-chip devices. While in recent years much of the work has concentrated on integrating complex molecular diagnostic assays onto a microfluidic device, there is a need to also put comparatively simple immunoassay-type protocols on a microfluidic platform. In this paper, we present the development of a microfluidic cartridge using an immunofiltration approach. In this method, the sandwich immunoassay takes place in a porous frit on which the antibodies have immobilized. The device is designed to be able to handle three samples in parallel and up to four analytical targets per sample. In order to meet the critical cost targets for the diagnostic market, the microfluidic chip has been designed and manufactured using high-volume manufacturing technologies in mind. Validation experiments show comparable sensitivities in comparison with conventional immunofiltration kits.

  9. Adaptive Code Division Multiple Access Protocol for Wireless Network-on-Chip Architectures

    Science.gov (United States)

    Vijayakumaran, Vineeth

    Massive levels of integration following Moore's Law ushered in a paradigm shift in the way on-chip interconnections were designed. With higher and higher number of cores on the same die traditional bus based interconnections are no longer a scalable communication infrastructure. On-chip networks were proposed enabled a scalable plug-and-play mechanism for interconnecting hundreds of cores on the same chip. Wired interconnects between the cores in a traditional Network-on-Chip (NoC) system, becomes a bottleneck with increase in the number of cores thereby increasing the latency and energy to transmit signals over them. Hence, there has been many alternative emerging interconnect technologies proposed, namely, 3D, photonic and multi-band RF interconnects. Although they provide better connectivity, higher speed and higher bandwidth compared to wired interconnects; they also face challenges with heat dissipation and manufacturing difficulties. On-chip wireless interconnects is one other alternative proposed which doesn't need physical interconnection layout as data travels over the wireless medium. They are integrated into a hybrid NOC architecture consisting of both wired and wireless links, which provides higher bandwidth, lower latency, lesser area overhead and reduced energy dissipation in communication. However, as the bandwidth of the wireless channels is limited, an efficient media access control (MAC) scheme is required to enhance the utilization of the available bandwidth. This thesis proposes using a multiple access mechanism such as Code Division Multiple Access (CDMA) to enable multiple transmitter-receiver pairs to send data over the wireless channel simultaneously. It will be shown that such a hybrid wireless NoC with an efficient CDMA based MAC protocol can significantly increase the performance of the system while lowering the energy dissipation in data transfer. In this work it is shown that the wireless NoC with the proposed CDMA based MAC protocol

  10. Characterizing Rat PNS Electrophysiological Response to Electrical Stimulation Using in vitro Chip-Based Human Investigational Platform (iCHIP)

    Energy Technology Data Exchange (ETDEWEB)

    Khani, Joshua [Georgetown Univ., Washington, DC (United States); Prescod, Lindsay [Georgetown Univ., Washington, DC (United States); Enright, Heather [Georgetown Univ., Washington, DC (United States); Felix, Sarah [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Osburn, Joanne [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wheeler, Elizabeth [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kulp, Kris [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-08-18

    Ex vivo systems and organ-on-a-chip technology offer an unprecedented approach to modeling the inner workings of the human body. The ultimate goal of LLNL’s in vitro Chip-based Human Investigational Platform (iCHIP) is to integrate multiple organ tissue cultures using microfluidic channels, multi-electrode arrays (MEA), and other biosensors in order to effectively simulate and study the responses and interactions of the major organs to chemical and physical stimulation. In this study, we focused on the peripheral nervous system (PNS) component of the iCHIP system. Specifically we sought to expound on prior research investigating the electrophysiological response of rat dorsal root ganglion cells (rDRGs) to chemical exposures, such as capsaicin. Our aim was to establish a protocol for electrical stimulation using the iCHIP device that would reliably elicit a characteristic response in rDRGs. By varying the parameters for both the stimulation properties – amplitude, phase width, phase shape, and stimulation/ return configuration – and the culture conditions – day in vitro and neural cell types - we were able to make several key observations and uncover a potential convention with a minimal number of devices tested. Future work will seek to establish a standard protocol for human DRGs in the iCHIP which will afford a portable, rapid method for determining the effects of toxins and novel therapeutics on the PNS.

  11. Space division multiplexing chip-to-chip quantum key distribution

    DEFF Research Database (Denmark)

    Bacco, Davide; Ding, Yunhong; Dalgaard, Kjeld

    2017-01-01

    nodes of the quantum keys to their respective destinations. In this paper we present an experimental demonstration of a photonic integrated silicon chip quantum key distribution protocols based on space division multiplexing (SDM), through multicore fiber technology. Parallel and independent quantum...

  12. Opto-electronic DNA chip-based integrated card for clinical diagnostics.

    Science.gov (United States)

    Marchand, Gilles; Broyer, Patrick; Lanet, Véronique; Delattre, Cyril; Foucault, Frédéric; Menou, Lionel; Calvas, Bernard; Roller, Denis; Ginot, Frédéric; Campagnolo, Raymond; Mallard, Frédéric

    2008-02-01

    Clinical diagnostics is one of the most promising applications for microfluidic lab-on-a-chip or lab-on-card systems. DNA chips, which provide multiparametric data, are privileged tools for genomic analysis. However, automation of molecular biology protocol and use of these DNA chips in fully integrated systems remains a great challenge. Simplicity of chip and/or card/instrument interfaces is amongst the most critical issues to be addressed. Indeed, current detection systems for DNA chip reading are often complex, expensive, bulky and even limited in terms of sensitivity or accuracy. Furthermore, for liquid handling in the lab-on-cards, many devices use complex and bulky systems, either to directly manipulate fluids, or to ensure pneumatic or mechanical control of integrated valves. All these drawbacks prevent or limit the use of DNA-chip-based integrated systems, for point-of-care testing or as a routine diagnostics tool. We present here a DNA-chip-based protocol integration on a plastic card for clinical diagnostics applications including: (1) an opto-electronic DNA-chip, (2) fluid handling using electrically activated embedded pyrotechnic microvalves with closing/opening functions. We demonstrate both fluidic and electric packaging of the optoelectronic DNA chip without major alteration of its electronical and biological functionalities, and fluid control using novel electrically activable pyrotechnic microvalves. Finally, we suggest a complete design of a card dedicated to automation of a complex biological protocol with a fully electrical fluid handling and DNA chip reading.

  13. Hybridization of Environmental Microbial Community Nucleic Acids by GeoChip.

    Science.gov (United States)

    Van Nostrand, Joy D; Yin, Huaqin; Wu, Liyou; Yuan, Tong; Zhou, Jizhong

    2016-01-01

    Functional gene arrays, like the GeoChip, allow for the study of tens of thousands of genes in a single assay. The GeoChip array (5.0) contains probes for genes involved in geochemical cycling (N, C, S, and P), metal homeostasis, stress response, organic contaminant degradation, antibiotic resistance, secondary metabolism, and virulence factors as well as genes specific for fungi, protists, and viruses. Here, we briefly describe GeoChip design strategies (gene selection and probe design) and discuss minimum quantity and quality requirements for nucleic acids. We then provide detailed protocols for amplification, labeling, and hybridization of samples to the GeoChip.

  14. Experiment list: SRX810435 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available idity in Shneider S2 Drosophila medium(Gibco) supplement...ster; ChIP-Seq source_name=Cell culture || cell line=S2 || chip antibody=none || growth protocol=S2 cells were grown in 24°C, 95% hum

  15. Experiment list: SRX810433 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available er; ChIP-Seq source_name=Cell culture || cell line=S2 || chip antibody=none || growth protocol=S2 cells were grown in 24°C, 95% humid...ity in Shneider S2 Drosophila medium(Gibco) supplemented

  16. Experiment list: SRX810434 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available idity in Shneider S2 Drosophila medium(Gibco) supplement...ster; ChIP-Seq source_name=Cell culture || cell line=S2 || chip antibody=none || growth protocol=S2 cells were grown in 24°C, 95% hum

  17. The Advances, Challenges and Future Possibilities of Millimeter-Wave Chip-to-Chip Interconnections for Multi-Chip Systems

    Directory of Open Access Journals (Sweden)

    Amlan Ganguly

    2018-02-01

    Full Text Available With aggressive scaling of device geometries, density of manufacturing faults is expected to increase. Therefore, yield of complex Multi-Processor Systems-on-Chips (MP-SoCs will decrease due to higher probability of manufacturing defects especially, in dies with large area. Therefore, disintegration of large SoCs into smaller chips called chiplets will improve yield and cost of complex platform-based systems. This will also provide functional flexibility, modular scalability as well as the capability to integrate heterogeneous architectures and technologies in a single unit. However, with scaling of the number of chiplets in such a system, the shared resources in the system such as the interconnection fabric and memory modules will become performance bottlenecks. Additionally, the integration of heterogeneous chiplets operating at different frequencies and voltages can be challenging. State-of-the-art inter-chip communication requires power-hungry high-speed I/O circuits and data transfer over long wired traces on substrates. This increases energy consumption and latency while decreasing data bandwidth for chip-to-chip communication. In this paper, we explore the advances and the challenges of interconnecting a multi-chip system with millimeter-wave (mm-wave wireless interconnects from a variety of perspectives spanning multiple aspects of the wireless interconnection design. Our discussion on the recent advances include aspects such as interconnection topology, physical layer, Medium Access Control (MAC and routing protocols. We also present some potential paradigm-shifting applications as well as complementary technologies of wireless inter-chip communications.

  18. SNP typing on the NanoChip electronic microarray

    DEFF Research Database (Denmark)

    Børsting, Claus; Sanchez Sanchez, Juan Jose; Morling, Niels

    2005-01-01

    We describe a single nucleotide polymorphism (SNP) typing protocol developed for the NanoChip electronic microarray. The NanoChip array consists of 100 electrodes covered by a thin hydrogel layer containing streptavidin. An electric currency can be applied to one, several, or all electrodes...

  19. Modelling, Synthesis, and Configuration of Networks-on-Chips

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo

    This thesis presents three contributions in two different areas of network-on-chip and system-on-chip research: Application modelling and identifying and solving different optimization problems related to two specific network-on-chip architectures. The contribution related to application modelling...... is an analytical method for deriving the worst-case traffic pattern caused by an application and the cache-coherence protocol in a cache-coherent shared-memory system. The contributions related to network-on-chip optimization problems consist of two parts: The development and evaluation of six heuristics...... for solving the network synthesis problem in the MANGO network-on-chip, and the identification and formalization of the ReNoC configuration problem together with three heuristics for solving it....

  20. Distributed Processing Using Single-chip Microcomputers

    National Research Council Canada - National Science Library

    Pritchett, William

    1996-01-01

    This project investigates the use of single-chip microprocessors as nodes in a token ring control network and explores the implementation of a protocol to manage communication across such a network...

  1. Experiments with Rydberg atoms on a current-carrying atom chip

    NARCIS (Netherlands)

    Cisternas San Martín, N.V.

    2018-01-01

    On one side, atom-chip experiments have demonstrated to be a versatile tool to study quantum physics in cold atoms systems. On the other side, Rydberg atoms have exaggerated properties that makes them good candidates to study quantum information and quantum simulations protocols. In this thesis both

  2. Avoiding Message-Dependent Deadlock in Network-Based Systems on Chip

    NARCIS (Netherlands)

    Hansson, A.; Goossens, K.; Rãdulescu, A.

    2007-01-01

    Networks on chip (NoCs) are an essential component of systems on chip (SoCs) and much research is devoted to deadlock avoidance in NoCs. Prior work focuses on the router network while protocol interactions between NoC and intellectual property (IP) modules are not considered. These interactions

  3. STUDY OF CHIP IGNITION AND CHIP MORPHOLOGY AFTER MILLING OF MAGNESIUM ALLOYS

    Directory of Open Access Journals (Sweden)

    Ireneusz Zagórski

    2016-12-01

    Full Text Available The paper analyses the impact of specified technological parameters of milling (vc, fz, ap on time to ignition. Stages leading to chip ignition were analysed. Metallographic images of magnesium chip were presented. No significant difference was observed in time to ignition in different chip fractions. Moreover, the surface of chips was free of products of ignition and signs of strong oxidation.

  4. "NeuroStem Chip": a novel highly specialized tool to study neural differentiation pathways in human stem cells

    Directory of Open Access Journals (Sweden)

    Li Jia-Yi

    2007-02-01

    Full Text Available Abstract Background Human stem cells are viewed as a possible source of neurons for a cell-based therapy of neurodegenerative disorders, such as Parkinson's disease. Several protocols that generate different types of neurons from human stem cells (hSCs have been developed. Nevertheless, the cellular mechanisms that underlie the development of neurons in vitro as they are subjected to the specific differentiation protocols are often poorly understood. Results We have designed a focused DNA (oligonucleotide-based large-scale microarray platform (named "NeuroStem Chip" and used it to study gene expression patterns in hSCs as they differentiate into neurons. We have selected genes that are relevant to cells (i being stem cells, (ii becoming neurons, and (iii being neurons. The NeuroStem Chip has over 1,300 pre-selected gene targets and multiple controls spotted in quadruplicates (~46,000 spots total. In this study, we present the NeuroStem Chip in detail and describe the special advantages it offers to the fields of experimental neurology and stem cell biology. To illustrate the utility of NeuroStem Chip platform, we have characterized an undifferentiated population of pluripotent human embryonic stem cells (hESCs, cell line SA02. In addition, we have performed a comparative gene expression analysis of those cells versus a heterogeneous population of hESC-derived cells committed towards neuronal/dopaminergic differentiation pathway by co-culturing with PA6 stromal cells for 16 days and containing a few tyrosine hydroxylase-positive dopaminergic neurons. Conclusion We characterized the gene expression profiles of undifferentiated and dopaminergic lineage-committed hESC-derived cells using a highly focused custom microarray platform (NeuroStem Chip that can become an important research tool in human stem cell biology. We propose that the areas of application for NeuroStem microarray platform could be the following: (i characterization of the

  5. Variation Tolerant On-Chip Interconnects

    CERN Document Server

    Nigussie, Ethiopia Enideg

    2012-01-01

    This book presents design techniques, analysis and implementation of high performance and power efficient, variation tolerant on-chip interconnects.  Given the design paradigm shift to multi-core, interconnect-centric designs and the increase in sources of variability and their impact in sub-100nm technologies, this book will be an invaluable reference for anyone concerned with the design of next generation, high-performance electronics systems. Provides comprehensive, circuit-level explanation of high-performance, energy-efficient, variation-tolerant on-chip interconnect; Describes design techniques to mitigate problems caused by variation; Includes techniques for design and implementation of self-timed on-chip interconnect, delay variation insensitive communication protocols, high speed signaling techniques and circuits, bit-width independent completion detection and process, voltage and temperature variation tolerance.                          

  6. "Hook"-calibration of GeneChip-microarrays: Chip characteristics and expression measures

    Directory of Open Access Journals (Sweden)

    Krohn Knut

    2008-08-01

    Full Text Available Abstract Background Microarray experiments rely on several critical steps that may introduce biases and uncertainty in downstream analyses. These steps include mRNA sample extraction, amplification and labelling, hybridization, and scanning causing chip-specific systematic variations on the raw intensity level. Also the chosen array-type and the up-to-dateness of the genomic information probed on the chip affect the quality of the expression measures. In the accompanying publication we presented theory and algorithm of the so-called hook method which aims at correcting expression data for systematic biases using a series of new chip characteristics. Results In this publication we summarize the essential chip characteristics provided by this method, analyze special benchmark experiments to estimate transcript related expression measures and illustrate the potency of the method to detect and to quantify the quality of a particular hybridization. It is shown that our single-chip approach provides expression measures responding linearly on changes of the transcript concentration over three orders of magnitude. In addition, the method calculates a detection call judging the relation between the signal and the detection limit of the particular measurement. The performance of the method in the context of different chip generations and probe set assignments is illustrated. The hook method characterizes the RNA-quality in terms of the 3'/5'-amplification bias and the sample-specific calling rate. We show that the proper judgement of these effects requires the disentanglement of non-specific and specific hybridization which, otherwise, can lead to misinterpretations of expression changes. The consequences of modifying probe/target interactions by either changing the labelling protocol or by substituting RNA by DNA targets are demonstrated. Conclusion The single-chip based hook-method provides accurate expression estimates and chip-summary characteristics

  7. An economic evaluation of a chlorhexidine chip for treating chronic periodontitis: the CHIP (chlorhexidine in periodontitis) study.

    Science.gov (United States)

    Henke, C J; Villa, K F; Aichelmann-Reidy, M E; Armitage, G C; Eber, R M; Genco, R J; Killoy, W J; Miller, D P; Page, R C; Polson, A M; Ryder, M I; Silva, S J; Somerman, M J; Van Dyke, T E; Wolff, L F; Evans, C J; Finkelman, R D

    2001-11-01

    The authors previously suggested that an adjunctive, controlled-release chlorhexidine, or CHX, chip may reduce periodontal surgical needs at little additional cost. This article presents an economic analysis of the CHX chip in general dental practice. In a one-year prospective clinical trial, 484 chronic periodontitis patients in 52 general practices across the United States were treated with either scaling and root planing, or SRP, plus any therapy prescribed by treating, unblinded dentists; or SRP plus other therapy as above but including the CHX chip. Economic data were collected from bills, case report forms and 12-month treatment recommendations from blinded periodontist evaluators. Total dental charges were higher for SRP + CHX chip patients vs. SRP patients when CHX chip costs were included (P = .027) but lower when CHX chip costs were excluded (P = .012). About one-half of the CHX chip acquisition cost was offset by savings in other charges. SRP + CHX chip patients were about 50 percent less likely to undergo surgical procedures than were SRP patients (P = .021). At the end of the trial, periodontist evaluators recommended similar additional procedures for both groups: SRP, about 46 percent; maintenance, about 37 percent; surgery, 56 percent for SRP alone and 63 percent for SRP + CHX chip. Adjunctive CHX chip use for general-practice patients with periodontitis increased costs but reduced surgeries over one year. At study's end, periodontists recommended similar additional surgical treatment for both groups. In general practice, routine use of the CHX chip suggests that costs will be partially offset by reduced surgery over at least one year.

  8. Experiment list: SRX684263 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ce_name=Cell culture || cell line=HEK 293 || chip antibody=none || growth protocol=HEK293 cells were grown in 37°C, 5% CO2, 95% humid...ity in high glucose DMEM (Invitrogen) supplemented with

  9. Experiment list: SRX684265 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ce_name=Cell culture || cell line=HEK 293 || chip antibody=none || growth protocol=HEK293 cells were grown in 37°C, 5% CO2, 95% humid...ity in high glucose DMEM (Invitrogen) supplemented with

  10. μOrgano: A Lego®-Like Plug & Play System for Modular Multi-Organ-Chips.

    Directory of Open Access Journals (Sweden)

    Peter Loskill

    Full Text Available Human organ-on-a-chip systems for drug screening have evolved as feasible alternatives to animal models, which are unreliable, expensive, and at times erroneous. While chips featuring single organs can be of great use for both pharmaceutical testing and basic organ-level studies, the huge potential of the organ-on-a-chip technology is revealed by connecting multiple organs on one chip to create a single integrated system for sophisticated fundamental biological studies and devising therapies for disease. Furthermore, since most organ-on-a-chip systems require special protocols with organ-specific media for the differentiation and maturation of the tissues, multi-organ systems will need to be temporally customizable and flexible in terms of the time point of connection of the individual organ units. We present a customizable Lego®-like plug & play system, μOrgano, which enables initial individual culture of single organ-on-a-chip systems and subsequent connection to create integrated multi-organ microphysiological systems. As a proof of concept, the μOrgano system was used to connect multiple heart chips in series with excellent cell viability and spontaneously physiological beat rates.

  11. μOrgano: A Lego®-Like Plug & Play System for Modular Multi-Organ-Chips.

    Science.gov (United States)

    Loskill, Peter; Marcus, Sivan G; Mathur, Anurag; Reese, Willie Mae; Healy, Kevin E

    2015-01-01

    Human organ-on-a-chip systems for drug screening have evolved as feasible alternatives to animal models, which are unreliable, expensive, and at times erroneous. While chips featuring single organs can be of great use for both pharmaceutical testing and basic organ-level studies, the huge potential of the organ-on-a-chip technology is revealed by connecting multiple organs on one chip to create a single integrated system for sophisticated fundamental biological studies and devising therapies for disease. Furthermore, since most organ-on-a-chip systems require special protocols with organ-specific media for the differentiation and maturation of the tissues, multi-organ systems will need to be temporally customizable and flexible in terms of the time point of connection of the individual organ units. We present a customizable Lego®-like plug & play system, μOrgano, which enables initial individual culture of single organ-on-a-chip systems and subsequent connection to create integrated multi-organ microphysiological systems. As a proof of concept, the μOrgano system was used to connect multiple heart chips in series with excellent cell viability and spontaneously physiological beat rates.

  12. Rapid manufacturing of low-noise membranes for nanopore sensors by trans-chip illumination lithography

    International Nuclear Information System (INIS)

    Janssen, Xander J A; Jonsson, Magnus P; Plesa, Calin; Soni, Gautam V; Dekker, Cees; Dekker, Nynke H

    2012-01-01

    In recent years, the concept of nanopore sensing has matured from a proof-of-principle method to a widespread, versatile technique for the study of biomolecular properties and interactions. While traditional nanopore devices based on a nanopore in a single layer membrane supported on a silicon chip can be rapidly fabricated using standard microfabrication methods, chips with additional insulating layers beyond the membrane region can provide significantly lower noise levels, but at the expense of requiring more costly and time-consuming fabrication steps. Here we present a novel fabrication protocol that overcomes this issue by enabling rapid and reproducible manufacturing of low-noise membranes for nanopore experiments. The fabrication protocol, termed trans-chip illumination lithography, is based on illuminating a membrane-containing wafer from its backside such that a photoresist (applied on the wafer’s top side) is exposed exclusively in the membrane regions. Trans-chip illumination lithography permits the local modification of membrane regions and hence the fabrication of nanopore chips containing locally patterned insulating layers. This is achieved while maintaining a well-defined area containing a single thin membrane for nanopore drilling. The trans-chip illumination lithography method achieves this without relying on separate masks, thereby eliminating time-consuming alignment steps as well as the need for a mask aligner. Using the presented approach, we demonstrate rapid and reproducible fabrication of nanopore chips that contain small (12 μm × 12 μm) free-standing silicon nitride membranes surrounded by insulating layers. The electrical noise characteristics of these nanopore chips are shown to be superior to those of simpler designs without insulating layers and comparable in quality to more complex designs that are more challenging to fabricate. (paper)

  13. Multiplex PCR, amplicon size and hybridization efficiency on the NanoChip electronic microarray

    DEFF Research Database (Denmark)

    Børsting, Claus; Sanchez, Juan J; Morling, Niels

    2004-01-01

    We tested the SNP typing protocol developed for the NanoChip electronic microarray by analyzing the four Y chromosome loci SRY1532, SRY8299, TAT, and 92R7. Amplicons of different lengths containing the same locus were purified and addressed to the NanoChip array and fluorescently labelled reporte...

  14. Edge chipping and flexural resistance of monolithic ceramics☆

    Science.gov (United States)

    Zhang, Yu; Lee, James J.-W.; Srikanth, Ramanathan; Lawn, Brian R.

    2014-01-01

    Objective Test the hypothesis that monolithic ceramics can be developed with combined esthetics and superior fracture resistance to circumvent processing and performance drawbacks of traditional all-ceramic crowns and fixed-dental-prostheses consisting of a hard and strong core with an esthetic porcelain veneer. Specifically, to demonstrate that monolithic prostheses can be produced with a much reduced susceptibility to fracture. Methods Protocols were applied for quantifying resistance to chipping as well as resistance to flexural failure in two classes of dental ceramic, microstructurally-modified zirconias and lithium disilicate glass–ceramics. A sharp indenter was used to induce chips near the edges of flat-layer specimens, and the results compared with predictions from a critical load equation. The critical loads required to produce cementation surface failure in monolithic specimens bonded to dentin were computed from established flexural strength relations and the predictions validated with experimental data. Results Monolithic zirconias have superior chipping and flexural fracture resistance relative to their veneered counterparts. While they have superior esthetics, glass–ceramics exhibit lower strength but higher chip fracture resistance relative to porcelain-veneered zirconias. Significance The study suggests a promising future for new and improved monolithic ceramic restorations, with combined durability and acceptable esthetics. PMID:24139756

  15. Use of a Microprocessor to Implement an ADCCP Protocol (Federal Standard 1003).

    Science.gov (United States)

    1980-07-01

    results of other studies, to evaluate the operational and economic impact of incorporating various options in Federal Standard 1003. The effort...the LSI interface and the microprocessor; the LSI chip deposits bytes in its buffer as the producer, and the MPU reads this data as the consumer...on the interface between the MPU and the LSI protocol chip. This requires two main processes to be running at the same time--transmit and receive. The

  16. Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.

    Science.gov (United States)

    Mauk, Michael G; Liu, Changchun; Qiu, Xianbo; Chen, Dafeng; Song, Jinzhao; Bau, Haim H

    2017-01-01

    Microfluidic cassettes ("chips") for processing and analysis of clinical specimens and other sample types facilitate point-of-care (POC) immunoassays and nucleic acid based amplification tests. These single-use test chips can be self-contained and made amenable to autonomous operation-reducing or eliminating supporting instrumentation-by incorporating laminated, pliable "pouch" and membrane structures for fluid storage, pumping, mixing, and flow control. Materials and methods for integrating flexible pouch compartments and diaphragm valves into hard plastic (e.g., acrylic and polycarbonate) microfluidic "chips" for reagent storage, fluid actuation, and flow control are described. We review several versions of these pouch chips for immunoassay and nucleic acid amplification tests, and describe related fabrication techniques. These protocols thus offer a "toolbox" of methods for storage, pumping, and flow control functions in microfluidic devices.

  17. Unconditionally Secure Credit/Debit Card Chip Scheme and Physical Unclonable Function

    Science.gov (United States)

    Kish, Laszlo B.; Entesari, Kamran; Granqvist, Claes-Göran; Kwan, Chiman

    The statistical-physics-based Kirchhoff-law-Johnson-noise (KLJN) key exchange offers a new and simple unclonable system for credit/debit card chip authentication and payment. The key exchange, the authentication and the communication are unconditionally secure so that neither mathematics- nor statistics-based attacks are able to crack the scheme. The ohmic connection and the short wiring lengths between the chips in the card and the terminal constitute an ideal setting for the KLJN protocol, and even its simplest versions offer unprecedented security and privacy for credit/debit card chips and applications of physical unclonable functions (PUFs).

  18. Route to one-step microstructure mold fabrication for PDMS microfluidic chip

    Science.gov (United States)

    Lv, Xiaoqing; Geng, Zhaoxin; Fan, Zhiyuan; Wang, Shicai; Su, Yue; Fang, Weihao; Pei, Weihua; Chen, Hongda

    2018-04-01

    The microstructure mold fabrication for PDMS microfluidic chip remains complex and time-consuming process requiring special equipment and protocols: photolithography and etching. Thus, a rapid and cost-effective method is highly needed. Comparing with the traditional microfluidic chip fabricating process based on the micro-electromechanical system (MEMS), this method is simple and easy to implement, and the whole fabrication process only requires 1-2 h. Different size of microstructure from 100 to 1000 μm was fabricated, and used to culture four kinds of breast cancer cell lines. Cell viability and morphology was assessed when they were cultured in the micro straight channels, micro square holes and the bonding PDMS-glass microfluidic chip. The experimental results indicate that the microfluidic chip is good and meet the experimental requirements. This method can greatly reduce the process time and cost of the microfluidic chip, and provide a simple and effective way for the structure design and in the field of biological microfabrications and microfluidic chips.

  19. Venom On-a-Chip: A Fast and Efficient Method for Comparative Venomics.

    Science.gov (United States)

    Zancolli, Giulia; Sanz, Libia; Calvete, Juan J; Wüster, Wolfgang

    2017-05-28

    Venom research has attracted an increasing interest in disparate fields, from drug development and pharmacology, to evolutionary biology and ecology, and rational antivenom production. Advances in "-omics" technologies have allowed the characterization of an increasing number of animal venoms, but the methodology currently available is suboptimal for large-scale comparisons of venom profiles. Here, we describe a fast, reproducible and semi-automated protocol for investigating snake venom variability, especially at the intraspecific level, using the Agilent Bioanalyzer on-chip technology. Our protocol generated a phenotype matrix which can be used for robust statistical analysis and correlations of venom variation with ecological correlates, or other extrinsic factors. We also demonstrate the ease and utility of combining on-chip technology with previously fractionated venoms for detection of specific individual toxin proteins. Our study describes a novel strategy for rapid venom discrimination and analysis of compositional variation at multiple taxonomic levels, allowing researchers to tackle evolutionary questions and unveiling the drivers of the incredible biodiversity of venoms.

  20. Experiment list: SRX190205 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available labexpid=SL7110,SL8075 || softwareversion=MACS || cell sex=M || antibody=NRSF ||...ChIP protocol & AMpure XP size selection for ChIP-seq (Myers) || controlid=SL6021 || labexpid=SL7110,SL8075 || replicate=1,2 || softw...areversion=MACS http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/eachData/bw/SRX1902

  1. Metaphase FISH on a Chip: Miniaturized Microfluidic Device for Fluorescence in situ Hybridization

    DEFF Research Database (Denmark)

    Vedarethinam, Indumathi; Shah, Pranjul Jaykumar; Dimaki, Maria

    2010-01-01

    -FISH, the process continues to be a manual, labour intensive, expensive and time consuming technique, often taking over 3-5 days, even in dedicated labs. We have developed a novel microFISH device to perform metaphase FISH on a chip which overcomes many shortcomings of the current laboratory protocols. This work...... also introduces a novel splashing device for preparing metaphase spreads on a microscope glass slide, followed by a rapid adhesive tape-based bonding protocol leading to rapid fabrication of the microFISH device. The microFISH device allows for an optimized metaphase FISH protocol on a chip with over...... a 20-fold reduction in the reagent volume. This is the first demonstration of metaphase FISH on a microfluidic device and offers a possibility of automation and significant cost reduction of many routine diagnostic tests of genetic anomalies....

  2. Implementation of Guaranteed Services in the MANGO Clockless Network-on-Chip

    DEFF Research Database (Denmark)

    Bjerregaard, Tobias; Sparsø, Jens

    2006-01-01

    (clockless implementation, standard socket access points, and guaranteed communication services) make MANGO suitable for a modular SoC design flow is explained. Among the advantages of using clockless circuit techniques are inherent global timing closure, low forward latency in pipelines, and zero dynamic......Shared, segmented, on-chip interconnection networks, known as networks-on-chip (NoC), may become the preferred way of interconnecting intellectual property (IP) cores in future giga-scale system-on-chip (SoC) designs. A NoC can provide the required communication bandwidth while accommodating...... the effects of scaling microchip technologies. Equally important, a NoC facilitates a truly modular and scalable design flow. The MANGO (message-passing asynchronous network-on-chip providing guaranteed services over open core protocol (OCP) interfaces) NoC is presented, and how its key characteristics...

  3. A multilevel Lab on chip platform for DNA analysis.

    Science.gov (United States)

    Marasso, Simone Luigi; Giuri, Eros; Canavese, Giancarlo; Castagna, Riccardo; Quaglio, Marzia; Ferrante, Ivan; Perrone, Denis; Cocuzza, Matteo

    2011-02-01

    Lab-on-chips (LOCs) are critical systems that have been introduced to speed up and reduce the cost of traditional, laborious and extensive analyses in biological and biomedical fields. These ambitious and challenging issues ask for multi-disciplinary competences that range from engineering to biology. Starting from the aim to integrate microarray technology and microfluidic devices, a complex multilevel analysis platform has been designed, fabricated and tested (All rights reserved-IT Patent number TO2009A000915). This LOC successfully manages to interface microfluidic channels with standard DNA microarray glass slides, in order to implement a complete biological protocol. Typical Micro Electro Mechanical Systems (MEMS) materials and process technologies were employed. A silicon/glass microfluidic chip and a Polydimethylsiloxane (PDMS) reaction chamber were fabricated and interfaced with a standard microarray glass slide. In order to have a high disposable system all micro-elements were passive and an external apparatus provided fluidic driving and thermal control. The major microfluidic and handling problems were investigated and innovative solutions were found. Finally, an entirely automated DNA hybridization protocol was successfully tested with a significant reduction in analysis time and reagent consumption with respect to a conventional protocol.

  4. Inherent polarization entanglement generated from a monolithic semiconductor chip

    DEFF Research Database (Denmark)

    Horn, Rolf T.; Kolenderski, Piotr; Kang, Dongpeng

    2013-01-01

    Creating miniature chip scale implementations of optical quantum information protocols is a dream for many in the quantum optics community. This is largely because of the promise of stability and scalability. Here we present a monolithically integratable chip architecture upon which is built...... a photonic device primitive called a Bragg reflection waveguide (BRW). Implemented in gallium arsenide, we show that, via the process of spontaneous parametric down conversion, the BRW is capable of directly producing polarization entangled photons without additional path difference compensation, spectral...... as a serious contender on which to build large scale implementations of optical quantum processing devices....

  5. [A novel biologic electricity signal measurement based on neuron chip].

    Science.gov (United States)

    Lei, Yinsheng; Wang, Mingshi; Sun, Tongjing; Zhu, Qiang; Qin, Ran

    2006-06-01

    Neuron chip is a multiprocessor with three pipeline CPU; its communication protocol and control processor are integrated in effect to carry out the function of communication, control, attemper, I/O, etc. A novel biologic electronic signal measurement network system is composed of intelligent measurement nodes with neuron chip at the core. In this study, the electronic signals such as ECG, EEG, EMG and BOS can be synthetically measured by those intelligent nodes, and some valuable diagnostic messages are found. Wavelet transform is employed in this system to analyze various biologic electronic signals due to its strong time-frequency ability of decomposing signal local character. Better effect is gained. This paper introduces the hardware structure of network and intelligent measurement node, the measurement theory and the signal figure of data acquisition and processing.

  6. Consumption study and identification of methyl salicylate in spicy cassava chips

    International Nuclear Information System (INIS)

    Nirjana, Marlene; Anggadiredja, Kusnandar; Damayanti, Sophi

    2015-01-01

    Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students’ pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam’s addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive

  7. Consumption study and identification of methyl salicylate in spicy cassava chips

    Energy Technology Data Exchange (ETDEWEB)

    Nirjana, Marlene, E-mail: marlenenirjana@gmail.com; Anggadiredja, Kusnandar; Damayanti, Sophi [School of Pharmacy, Institut Teknologi Bandung Jalan Ganesha 10, Bandung 40132 (Indonesia)

    2015-09-30

    Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students’ pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam’s addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive

  8. Consumption study and identification of methyl salicylate in spicy cassava chips

    Science.gov (United States)

    Nirjana, Marlene; Anggadiredja, Kusnandar; Damayanti, Sophi

    2015-09-01

    Spicy cassava chips is a popular snack. However, some news in electronic media reported addition of balsam which is a banned food additives in that product to give extra spicy flavor. This study aimed to determine ITB students' pattern of consumption, health problems caused by spicy chips consumption, and knowledge about illicit use of food additives in that product, and identify the main content of balsam namely methyl salicylate in 10 samples of spicy cassava chips taken from inside and outside about ITB campus. A total of 300 questionnaires distributed to ITB students then data processing was performed. Spicy cassava chips sample macerated in 50 mL of methanol for 24 hours at room temperature, filtered and analyzed using gas chromatography capillary column with OV-1, nitrogen carrier gas and flame ionization detector. Based on questionnaires, 292 (97%) of 300 respondents had consumed spicy chips. A total of 247 (85%) from 292 respondents spicy chips consumed less than 3 times a week. A total of 195 respondents (67%) had experienced health problems after eating spicy chips. There were 137 (47%) of the 292 respondents who knew about the illicit addition of food additives into spicy chips; only 35 respondents (12%) who knew about balsam's addition. There were 126 respondents (43%) who did not pay attention to their health because they will keep eating spicy chips despite the addition of banned food additives. Through the verification of the standard addition method in gas chromatography system with a hydrogen pressure of 1.5 bar, injector temperature 200 °C, detector temperature 230 °C, oven temperature 60 °C for 2 minutes and then increased to 230 °C with rate 6 °C/menit; linearity, limit of detection, limit of quantitation, accuracy, precision, and specificity parameters met the acceptance limits. From 10 spicy cassava chips samples which were analyzed, they did not reveal any content of methyl salicylate. Methyl salicylate contained in the positive control

  9. A VXI-GPIB protocol converter based on DSP

    International Nuclear Information System (INIS)

    Hu Yuanfeng; Yu Xiaoqi; Lu Jingping

    2006-01-01

    A VXI-GPIB protocol converter based on DSP is introduced. The word-serial protocol with the message-based interface is implemented by EPLD and DSP. The GPIB functions are implemented by programming to the GPIB control chip. The transfer from VXI messages to GPIB functions is implemented by DSP. As an example of application, the control functions for oscilloscopes have been implemented in a VXI-GPIB heterogeneous system using such modules. (authors)

  10. Metaphase FISH on a Chip: Miniaturized Microfluidic Device for Fluorescence in situ Hybridization

    Directory of Open Access Journals (Sweden)

    Niels Tommerup

    2010-11-01

    Full Text Available Fluorescence in situ Hybridization (FISH is a major cytogenetic technique for clinical genetic diagnosis of both inherited and acquired chromosomal abnormalities. Although FISH techniques have evolved and are often used together with other cytogenetic methods like CGH, PRINS and PNA-FISH, the process continues to be a manual, labour intensive, expensive and time consuming technique, often taking over 3–5 days, even in dedicated labs. We have developed a novel microFISH device to perform metaphase FISH on a chip which overcomes many shortcomings of the current laboratory protocols. This work also introduces a novel splashing device for preparing metaphase spreads on a microscope glass slide, followed by a rapid adhesive tape-based bonding protocol leading to rapid fabrication of the microFISH device. The microFISH device allows for an optimized metaphase FISH protocol on a chip with over a 20-fold reduction in the reagent volume. This is the first demonstration of metaphase FISH on a microfluidic device and offers a possibility of automation and significant cost reduction of many routine diagnostic tests of genetic anomalies.

  11. Integration of microcoils for on-chip immunosensors based on magnetic nanoparticles capture

    Directory of Open Access Journals (Sweden)

    Olivier Lefebvre

    2017-04-01

    Full Text Available Immunoassays using magnetic nanoparticles (MNP are generally performed under the control of permanent magnet close to the micro-tube of reaction. Using a magnet gives a powerful method for driving MNP but remains unreliable or insufficient for a fully integrated immunoassay on lab-on-chip. The aim of this study is to develop a novel lab-on-chip concept for high efficient immunoassays to detect ovalbumin (Biodefense model molecule with microcoils employed for trapping MNP during the biofunctionalization steps. The objectives are essentially to optimize their efficiency for biological recognition by assuring a better bioactivity (antibodies-ovalbumin, and detect small concentrations of the targeted protein (~10 pg/mL. In this work, we studied the response of immunoassays complex function of ovalbumin concentration. The impact of MNP diameter in the biografting protocol was studied and permitted to choose a convenient MNP size for efficient biorecognition. We realized different immunoassays by controlling MNP in test tube and in microfluidic device using a permanent magnet. The comparison between these two experiments allows us to highlight an improvement of the limit of detection in microfluidic conditions by controlling MNP trapping with a magnet. Keywords: Bacteria, Lab-on-chip, ELISA, Magnetic nanoparticles, Ovalbumin, Microcoils, Fluorescent microscopy

  12. Silicon Chip-to-Chip Mode-Division Multiplexing

    DEFF Research Database (Denmark)

    Baumann, Jan Markus; Porto da Silva, Edson; Ding, Yunhong

    2018-01-01

    A chip-to-chip mode-division multiplexing connection is demonstrated using a pair of multiplexers/demultiplexers fabricated on the silicon-on-insulator platform. Successful mode multiplexing and demultiplexing is experimentally demonstrated, using the LP01, LP11a and LP11b modes.......A chip-to-chip mode-division multiplexing connection is demonstrated using a pair of multiplexers/demultiplexers fabricated on the silicon-on-insulator platform. Successful mode multiplexing and demultiplexing is experimentally demonstrated, using the LP01, LP11a and LP11b modes....

  13. Supply chains of forest chip production in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Kaerhae, Kalle (Metsaeteho Oy, Helsinki (Finland)), e-mail: kalle.karha@metsateho.fi

    2010-07-15

    The Metsaeteho study investigated how logging residue chips, stump wood chips, and chips from small sized thinning wood and large-sized (rotten) roundwood used by heating and power plants were produced in Finland in 2008. Almost all the major forest chip suppliers in Finland were involved in the study. The total volume of forest chips supplied in 2008 by these suppliers was 6.5 TWh. The study was implemented by conducting an e-mail questionnaire survey and telephone interviews. Research data was collected in March-May 2009. The majority of the logging residue chips and chips from small-sized thinning wood were produced using the roadside chipping supply chain in Finland in 2008. The chipping at plant supply chain was also significant in the production of logging residue chips. 70% of all stump wood chips consumed were comminuted at the plant and 29% at terminals. The role of the terminal chipping supply chain was also significant in the production of chips from logging residues and small-sized wood chips. When producing chips from large-sized (rotten) roundwood, nearly a half of chips were comminuted at plants and more than 40% at terminals

  14. Supply systems of forest chip production in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Kaerhae, K. (Metsaeteho Oy, Helsinki (Finland)), e-mail: kalle.karha@metsateho.fi

    2010-07-01

    The Metsaeteho study investigated how logging residue chips, stump wood chips, and chips from small-diameter thinning wood and large-sized (rotten) roundwood used by heating and power plants were produced in Finland in 2009. Almost all the major forest chip suppliers in Finland were involved in the study. The total volume of forest chips supplied in 2009 by these suppliers was 8,4 TWh. The study was implemented by conducting an e-mail questionnaire survey and telephone interviews. Research data was collected from March-May, 2010. The majority of the logging residue chips and chips from small-diameter thinning wood were produced using the roadside chipping supply system in Finland in 2009. The chipping at plant supply system was also significant in the production of logging residue chips. Nearly 70 % of all stump wood chips consumed were comminuted at the plant and 28 % at terminals. The role of the terminal chipping supply system was also significant in the production of chips from logging residues and small-diameter wood chips. When producing chips from large-sized (rotten) roundwood, similarly roughly 70 % of chips were comminuted at plants and 23 % at terminals. (orig.)

  15. Supply chains of forest chip production in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Kaerhae, K. (Metsaeteho Oy, Helsinki (Finland)), Email: kalle.karha@metsateho.fi

    2009-07-01

    The Metsaeteho study investigated how logging residue chips. stump wood chips, and chips from small-sized thinning wood and large-sized (rotten) roundwood used by heating and power plants were produced in Finland in 2008. Almost all the major forest chip suppliers in Finland were involved in the study. The total volume of forest chips supplied in 2008 by these suppliers was 6,5 TWh. The study was implemented by conducting an e-mail questionnaire survey and telephone interviews. Research data was collected in March-May 2009. The majority of the logging residue chips and chips from small-sized thinning wood were produced using the roadside chipping supply chain in Finland in 2008. The chipping at plant supply chain was also significant in the production of logging residue chips. 70% of all stump wood chips consumed were comminuted at the plant and 29% at terminals. The role of the terminal chipping supply chain was also significant in the production of chips from logging residues and small-sized wood chips. When producing chips from large-sized (rotten) roundwood, nearly a half of chips were comminuted at plants and more than 40 % at terminals. (orig.)

  16. MIL-STD-1553B Marconi LSI chip set in a remote terminal application

    Science.gov (United States)

    Dimarino, A.

    1982-11-01

    Marconi Avionics is utilizing the MIL-STD-1553B LSI Chip Set in the SCADC Air Data Computer application to perform all of the required remote terminal MIL-STD-1553B protocol functions. Basic components of the RTU are the dual redundant chip set, CT3231 Transceivers, 256 x 16 RAM and a Z8002 microprocessor. Basic transfers are to/from the RAM command of the bus controller or Z8002 processor. During transfers from the processor to the RAM, the chip set busy bit is set for a period not exceeding 250 microseconds. When the transfer is complete, the busy bit is released and transfers to the data bus occur on command. The LSI Chip Set word count lines are used to locate each data word in the local memory and 4 mode codes are used in the application: reset remote terminal, transmit status word, transmitter shut-down, and override transmitter shutdown.

  17. Publication trends of study protocols in rehabilitation.

    Science.gov (United States)

    Jesus, Tiago S; Colquhoun, Heather L

    2017-09-04

    Growing evidence points for the need to publish study protocols in the health field. To observe whether the growing interest in publishing study protocols in the broader health field has been translated into increased publications of rehabilitation study protocols. Observational study using publication data and its indexation in PubMed. Not applicable. Not applicable. PubMed was searched with appropriate combinations of Medical Subject Headings up to December 2014. The effective presence of study protocols was manually screened. Regression models analyzed the yearly growth of publications. Two-sample Z-tests analyzed whether the proportion of Systematic Reviews (SRs) and Randomized Controlled Trials (RCTs) among study protocols differed from that of the same designs for the broader rehabilitation research. Up to December 2014, 746 publications of rehabilitation study protocols were identified, with an exponential growth since 2005 (r2=0.981; p<0.001). RCT protocols were the most common among rehabilitation study protocols (83%), while RCTs were significantly more prevalent among study protocols than among the broader rehabilitation research (83% vs. 35.8%; p<0.001). For SRs, the picture was reversed: significantly less common among study protocols (2.8% vs. 9.3%; p<0.001). Funding was more often reported by rehabilitation study protocols than the broader rehabilitation research (90% vs. 53.1%; p<0.001). Rehabilitation journals published a significantly lower share of rehabilitation study protocols than they did for the broader rehabilitation research (1.8% vs.16.7%; p<0.001). Identifying the reasons for these discrepancies and reverting unwarranted disparities (e.g. low rate of publication for rehabilitation SR protocols) are likely new avenues for rehabilitation research and its publication. SRs, particularly those aggregating RCT results, are considered the best standard of evidence to guide rehabilitation clinical practice; however, that standard can be improved

  18. Study on irradiation effects of nucleus electromagnetic pulse on single chip computer system

    International Nuclear Information System (INIS)

    Hou Minsheng; Liu Shanghe; Wang Shuping

    2001-01-01

    Intense electromagnetic pulse, namely nucleus electromagnetic pulse (NEMP), lightning electromagnetic pulse (LEMP) and high power microwave (HPM), can disturb and destroy the single chip computer system. To study this issue, the authors made irradiation experiments by NEMPs generated by gigahertz transversal electromagnetic (GTEM) Cell. The experiments show that shutdown, restarting, communication errors of the single chip microcomputer system would occur when it was irradiated by the NEMPs. Based on the experiments, the cause on the effects on the single chip microcomputer system is discussed

  19. Experimental study of the chip morphology in turning hardened AISI D2 steel

    Energy Technology Data Exchange (ETDEWEB)

    Mhamdi, Mohamed Baccar; Bayraktar, Emin [Supmeca, Paris (France); Salem, Sahbi Ben; Boujelbene, Mohamed [National Engineering School of Tunis, Tunis (Turkey)

    2013-11-15

    The study of local mechanisms of material removal is essential in all problems of shaping by machining. Indeed, the mastery of surfaces generated by cutting requires an understanding of cutting mechanisms. The turning of steels with high mechanical properties using the cutting tool, often called 'hard turning,' is a new technique for the mechanical industry, and hence the need to understand the cutting mechanisms. The steel type EN X160CrMoV12 treated to 62 HRC (cold work tool steel: AISI D2 with a martensite matrix and distribution of primary and secondary carbides) is the subject of this study. Hard turning tests were carried out for this steel at different cutting conditions, with the aim to understand the mechanism of chip formation in order to be able to obtain the optimal cutting conditions. The chips obtained were examined under a microscope. The observation showed that the chip formation is influenced by cutting conditions. The chips contained a white layer, and this layer was examined under scanning electronic microscope (SEM) to study its variation depending on cutting parameters. The study shown, that cutting forces decrease with the increase of cutting speed. However, ANOVA method was used to establish the effect of the cutting conditions on experimental obtained results. Analysis of plastic deformation of the chip and the shear angle was made according to cutting conditions. Finally, a microhardness test was carried out to relate the mechanical properties and the microstructures of white layers.

  20. Towards cavitation-enhanced permeability in blood vessel on a chip

    Science.gov (United States)

    De Luca, R.; Silvani, G.; Scognamiglio, C.; Sinibaldi, G.; Peruzzi, G.; Chinappi, M.; Kiani, M. F.; Casciola, C. M.

    2017-08-01

    The development of targeted delivery systems releasing pharmaceutical agents directly at the desired site of action may improve their therapeutic efficiency while minimizing damage to healthy tissues, toxicity to the patient and drug waste. In this context, we have developed a bio-inspired microdevice mimicking the tumour microvasculature which represents a valuable tool for assessing the enhancement of blood vessel permeability due to cavitation. This novel system allows us to investigate the effects of ultrasound-driven microbubbles that temporarily open the endothelial intercellular junctions allowing drug to extravasate blood vessels into tumour tissues. The blood vessel on a chip consists of a tissue chamber and two independent vascular channels (width 200 µm, height 100 µm, length 2762 µm) cultured with endothelial cells placed side-by-side and separated by a series of 3 µm pores. Its geometry and dimensions mimic the three-dimensional morphology, size and flow characteristics of microvessels in vivo. The early stage of this project had a twofold objective: 1. To define the protocol for culturing of Human Umbilical Vein Endothelial Cells (HUVECs) within the vascular channel; 2. To develop a fluorescence based microscopy technique for measuring permeability. We have developed a reliable and reproducible protocol to culture endothelial cells within the artificial vessels in a realistic manner: HUVECs show the typical elongated shape in the direction of flow, exhibit tight junction formation and form a continuous layer with a central lumen that completely covers the channels wall. As expected, the permeability of cell-free device is higher than the one cultured with HUVECs in the vascular channels. The proposed blood vessel on a chip and the permeability measurement protocol have a significant potential to allow for the study of cavitation-enhanced permeability of the endothelium and improve efficiency in screening drug delivery systems.

  1. Implementation of Microfluidic Chip Electrophoresis for the Detection of B-cell Clonality

    Directory of Open Access Journals (Sweden)

    Vazan M

    2016-04-01

    Full Text Available Introduction: A clonal population of B-cells is defined as those cells arising from the mitotic division of a single somatic cell with the same rearrangement of immunoglobulin genes. This gives rise to DNA markers for each individual lymphoid cell and its progenies and enables us to study clonality in different B-cell malignancies using multiplex polymerase chain reaction - PCR. The BIOMED-2 protocol has been implemented for clonality detection in lymphoproliferative diseases and exploits multiplex PCR reaction, subsequently analyzed by heteroduplex analysis (HDA using polyacrylamide gel electrophoresis (PAGE. With the advent of miniaturization and automation of molecular biology methods, lab-on-chip technologies were developed and replace partially the conventional approaches. We tested device for microfluidic chip, which is used for B-cells clonality analysis, using a PCR reaction for three subregions called frameworks (FR of the immunoglobulin heavy locus (IGH gene.

  2. Chromatin Immunoprecipitation (ChIP): Revisiting the Efficacy of Sample Preparation, Sonication, Quantification of Sheared DNA, and Analysis via PCR

    Science.gov (United States)

    Schoppee Bortz, Pamela D.; Wamhoff, Brian R.

    2011-01-01

    The “quantitative” ChIP, a tool commonly used to study protein-DNA interactions in cells and tissue, is a difficult assay often plagued with technical error. We present, herein, the process required to merge multiple protocols into a quick, reliable and easy method and an approach to accurately quantify ChIP DNA prior to performing PCR. We demonstrate that high intensity sonication for at least 30 min is required for full cellular disruption and maximum DNA recovery because ChIP lysis buffers fail to lyse formaldehyde-fixed cells. In addition, extracting ChIP DNA with chelex-100 yields samples that are too dilute for evaluation of shearing efficiency or quantification via nanospectrophotometry. However, DNA extracted from the Mock-ChIP supernatant via the phenol-chloroform-isoamyl alcohol (PCIA) method can be used to evaluate DNA shearing efficiency and used as the standard in a fluorescence-based microplate assay. This enabled accurate quantification of DNA in chelex-extracted ChIP samples and normalization to total DNA concentration prior to performing real-time PCR (rtPCR). Thus, a quick ChIP assay that can be completed in nine bench hours over two days has been validated along with a rapid, accurate and repeatable way to quantify ChIP DNA. The resulting rtPCR data more accurately depicts treatment effects on protein-DNA interactions of interest. PMID:22046253

  3. Flip chip assembly of thinned chips for hybrid pixel detector applications

    International Nuclear Information System (INIS)

    Fritzsch, T; Zoschke, K; Rothermund, M; Oppermann, H; Woehrmann, M; Ehrmann, O; Lang, K D; Huegging, F

    2014-01-01

    There is a steady trend to ultra-thin microelectronic devices. Especially for future particle detector systems a reduced readout chip thickness is required to limit the loss of tracking precision due to scattering. The reduction of silicon thickness is performed at wafer level in a two-step thinning process. To minimize the risk of wafer breakage the thinned wafer needs to be handled by a carrier during the whole process chain of wafer bumping. Another key process is the flip chip assembly of thinned readout chips onto thin sensor tiles. Besides the prevention of silicon breakage the minimization of chip warpage is one additional task for a high yield and reliable flip chip process. A new technology using glass carrier wafer will be described in detail. The main advantage of this technology is the combination of a carrier support during wafer processing and the chip support during flip chip assembly. For that a glass wafer is glue-bonded onto the backside of the thinned readout chip wafer. After the bump deposition process the glass-readout chip stack is diced in one step. Finally the glass carrier chip is released by laser illumination after flip chip assembly of the readout chip onto sensor tile. The results of the flip chip assembly process development for the ATLAS IBL upgrade are described more in detail. The new ATLAS FEI4B chip with a size of 20 × 19 mm 2 is flip chip bonded with a thickness of only 150 μm, but the capability of this technology has been demonstrated on hybrid modules with a reduced readout chip thickness of down to 50 μm which is a major step for ultra-thin electronic systems

  4. Study of silicon chip soldering in high-power transistor housing

    Directory of Open Access Journals (Sweden)

    Vasily S. Anosov

    2017-09-01

    We experimentally assessed the effect of outer housing layer materials and back side chip metallization. For lead-silver soldering of silicon chips, the best housing is that with a nickel outer layer rather than with a gold-plated one, because the resultant thermal resistance is lower and the absence of gold makes the technology cheaper. We obtained a 0.6 K/W thermal resistance for a 24 mm2 chip area.

  5. Price of forest chips decreasing

    International Nuclear Information System (INIS)

    Hakkila, P.

    2001-01-01

    Use of forest chips was studied in 1999 in the national Puuenergia (Wood Energy) research program. Wood combusting heating plants were questioned about are the main reasons restricting the increment of the use of forest chips. Heating plants, which did not use forest chips at all or which used less than 250 m 3 (625 bulk- m 3 ) in 1999 were excluded. The main restrictions for additional use of forest chips were: too high price of forest chips; lack of suppliers and/or uncertainty of deliveries; technical problems of reception and processing of forest chips; insufficiency of boiler output especially in winter; and unsatisfactory quality of chips. The price of forest chips becomes relatively high because wood biomass used for production of forest chips has to be collected from wide area. Heavy equipment has to be used even though small fragments of wood are processed, which increases the price of chips. It is essential for forest chips that the costs can be pressed down because competition with fossil fuels, peat and industrial wood residues is hard. Low market price leads to the situation in which forest owner gets no price of the raw material, the entrepreneurs operate at the limit of profitability and renovation of machinery is difficult, and forest chips suppliers have to sell the chips at prime costs. Price of forest chips has decreased significantly during the past decade. Nominal price of forest chips is now lower than two decades ago. The real price of chips has decreased even more than the nominal price, 35% during the past decade and 20% during the last five years. Chips, made of small diameter wood, are expensive because the price includes the felling costs and harvesting is carried out at thinning lots. Price is especially high if chips are made of delimbed small diameter wood due to increased the work and reduced amount of chips. The price of logging residue chips is most profitable because cutting does not cause additional costs. Recovery of chips is

  6. Study on boiling heat transfer from diode elements in an integrated circuit chip

    Energy Technology Data Exchange (ETDEWEB)

    Hijikata, Kunio; Nagasaki, Takao; Kurata, Naoki (Tokyo Institute of Technology Faculty of Engineering (Japan))

    1989-02-25

    By temperature measurement of elements in boiling experiments with diodes in an integrated circuit (IC) chip, characteristics of boiling heat transfer from tiny heat generating elements in an IC chip and thermal transfer characteristics of multiple heating elements adjoining positioned were studied. The Package of an IC was removed by acid to expose the IC chip. Electricity is applied to the diode in the IC to study the heat transfer properties. The heat transfer rate from a tiny heating element on an IC is greater than that from the conventional continual heated surface. In the case of heat generation by two adjoining elements, the relationship between the total amount of heat and the temperature of elements shows the same characteristics as in the case with a single element. The boiling heat transfer properties of an element in an IC chip are influenced by such microstructure surrounding the element as the pattern of wiring. Heat transfer increases with the decreasing size of the heating element by the heat transfer to the substrate beneath the element. 10 refs., 15 figs.

  7. Low-Cost Energy-Efficient 3-D Nano-Spikes-Based Electric Cell Lysis Chips

    KAUST Repository

    Riaz, Kashif

    2017-05-04

    Electric cell lysis (ECL) is a promising technique to be integrated with portable lab-on-a-chip without lysing agent due to its simplicity and fast processing. ECL is usually limited by the requirements of high power/voltage and costly fabrication. In this paper, we present low-cost 3-D nano-spikes-based ECL (NSP-ECL) chips for efficient cell lysis at low power consumption. Highly ordered High-Aspect-Ratio (HAR). NSP arrays with controllable dimensions were fabricated on commercial aluminum foils through scalable and electrochemical anodization and etching. The optimized multiple pulse protocols with minimized undesirable electrochemical reactions (gas and bubble generation), common on micro parallel-plate ECL chips. Due to the scalability of fabrication process, 3-D NSPs were fabricated on small chips as well as on 4-in wafers. Phase diagram was constructed by defining critical electric field to induce cell lysis and for cell lysis saturation Esat to define non-ECL and ECL regions for different pulse parameters. NSP-ECL chips have achieved excellent cell lysis efficiencies ηlysis (ca 100%) at low applied voltages (2 V), 2~3 orders of magnitude lower than that of conventional systems. The energy consumption of NSP-ECL chips was 0.5-2 mJ/mL, 3~9 orders of magnitude lower as compared with the other methods (5J/mL-540kJ/mL). [2016-0305

  8. A volumetric meter chip for point-of-care quantitative detection of bovine catalase for food safety control

    International Nuclear Information System (INIS)

    Cui, Xingye; Hu, Jie; Choi, Jane Ru; Huang, Yalin; Wang, Xuemin; Lu, Tian Jian; Xu, Feng

    2016-01-01

    A volumetric meter chip was developed for quantitative point-of-care (POC) analysis of bovine catalase, a bioindicator of bovine mastitis, in milk samples. The meter chip displays multiplexed quantitative results by presenting the distance of ink bar advancement that is detectable by the naked eye. The meter chip comprises a poly(methyl methacrylate) (PMMA) layer, a double-sided adhesive (DSA) layer and a glass slide layer fabricated by the laser-etching method, which is typically simple, rapid (∼3 min per chip), and cost effective (∼$0.2 per chip). Specially designed “U shape” reaction cells are covered by an adhesive tape that serves as an on-off switch, enabling the simple operation of the assay. As a proof of concept, we employed the developed meter chip for the quantification of bovine catalase in raw milk samples to detect catalase concentrations as low as 20 μg/mL. The meter chip has great potential to detect various target analytes for a wide range of POC applications. - Highlights: • The meter chip is a standalone point-of-care diagnostic tool with visible readouts of quantification results. • A fast and low cost fabrication protocol (~3 min and ~$0.2 per chip) of meter chip was proposed. • The chip may hold the potential for rapid scaning of bovine mastitis in cattle farms for food safety control.

  9. A volumetric meter chip for point-of-care quantitative detection of bovine catalase for food safety control

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Xingye; Hu, Jie; Choi, Jane Ru; Huang, Yalin; Wang, Xuemin [The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049 (China); Bioinspired Engineering and Biomechanics Center (BEBC), Xi' an Jiaotong University, Xi' an, 710049 (China); Lu, Tian Jian, E-mail: tjlu@mail.xjtu.edu.cn [Bioinspired Engineering and Biomechanics Center (BEBC), Xi' an Jiaotong University, Xi' an, 710049 (China); Xu, Feng, E-mail: fengxu@mail.xjtu.edu.cn [The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi' an Jiaotong University, Xi' an, 710049 (China); Bioinspired Engineering and Biomechanics Center (BEBC), Xi' an Jiaotong University, Xi' an, 710049 (China)

    2016-09-07

    A volumetric meter chip was developed for quantitative point-of-care (POC) analysis of bovine catalase, a bioindicator of bovine mastitis, in milk samples. The meter chip displays multiplexed quantitative results by presenting the distance of ink bar advancement that is detectable by the naked eye. The meter chip comprises a poly(methyl methacrylate) (PMMA) layer, a double-sided adhesive (DSA) layer and a glass slide layer fabricated by the laser-etching method, which is typically simple, rapid (∼3 min per chip), and cost effective (∼$0.2 per chip). Specially designed “U shape” reaction cells are covered by an adhesive tape that serves as an on-off switch, enabling the simple operation of the assay. As a proof of concept, we employed the developed meter chip for the quantification of bovine catalase in raw milk samples to detect catalase concentrations as low as 20 μg/mL. The meter chip has great potential to detect various target analytes for a wide range of POC applications. - Highlights: • The meter chip is a standalone point-of-care diagnostic tool with visible readouts of quantification results. • A fast and low cost fabrication protocol (~3 min and ~$0.2 per chip) of meter chip was proposed. • The chip may hold the potential for rapid scaning of bovine mastitis in cattle farms for food safety control.

  10. Wax-bonding 3D microfluidic chips

    KAUST Repository

    Gong, Xiuqing; Yi, Xin; Xiao, Kang; Li, Shunbo; Kodzius, Rimantas; Qin, Jianhua; Wen, Weijia

    2013-01-01

    We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes . The hot-melt adhesive wax can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate (PMMA) film, glass sheets, or metal plate. The bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by vacuating and venting the chip in a hot-water bath. To study the biocompatibility and applicability of the wax-based microfluidic chip, we tested the PCR compatibility with the chip materials first. Then we applied the wax-paper based microfluidic chip to HeLa cell electroporation (EP ). Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein (GFP) recombinant Escherichia coli (E. coli) bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration.

  11. Wax-bonding 3D microfluidic chips

    KAUST Repository

    Gong, Xiuqing

    2013-10-10

    We report a simple, low-cost and detachable microfluidic chip incorporating easily accessible paper, glass slides or other polymer films as the chip materials along with adhesive wax as the recycling bonding material. We use a laser to cut through the paper or film to form patterns and then sandwich the paper and film between glass sheets or polymer membranes . The hot-melt adhesive wax can realize bridge bonding between various materials, for example, paper, polymethylmethacrylate (PMMA) film, glass sheets, or metal plate. The bonding process is reversible and the wax is reusable through a melting and cooling process. With this process, a three-dimensional (3D) microfluidic chip is achievable by vacuating and venting the chip in a hot-water bath. To study the biocompatibility and applicability of the wax-based microfluidic chip, we tested the PCR compatibility with the chip materials first. Then we applied the wax-paper based microfluidic chip to HeLa cell electroporation (EP ). Subsequently, a prototype of a 5-layer 3D chip was fabricated by multilayer wax bonding. To check the sealing ability and the durability of the chip, green fluorescence protein (GFP) recombinant Escherichia coli (E. coli) bacteria were cultured, with which the chemotaxis of E. coli was studied in order to determine the influence of antibiotic ciprofloxacin concentration on the E. coli migration.

  12. Fundamental study of microelectronic chip response under laser ultrasonic-interferometric inspection using C-scan method

    Science.gov (United States)

    Yang, Lei; Gong, Jie; Ume, I. Charles

    2014-02-01

    In modern surface mount packaging technologies, such as flip chips, chip scale packages, and ball grid arrays(BGA), chips are attached to the substrates/printed wiring board (PWB) using solder bump interconnections. The quality of solder bumps between the chips and the substrate/board is difficult to inspect. Laser ultrasonic-interferometric technique was proved to be a promising approach for solder bump inspection because of its noncontact and nondestructive characteristics. Different indicators extracted from received signals have been used to predict the potential defects, such as correlation coefficient, error ratio, frequency shifting, etc. However, the fundamental understanding of the chip behavior under laser ultrasonic inspection is still missing. Specifically, it is not sure whether the laser interferometer detected out-of-plane displacements were due to wave propagation or structural vibration when the chip was excited by pulsed laser. Plus, it is found that the received signals are chip dependent. Both challenges impede the interpretation of acquired signals. In this paper, a C-scan method was proposed to study the underlying phenomenon during laser ultrasonic inspection. The full chip was inspected. The response of the chip under laser excitation was visualized in a movie resulted from acquired signals. Specifically, a BGA chip was investigated to demonstrate the effectiveness of this method. By characterizing signals using discrete wavelet transform(DWT), both ultrasonic wave propagation and vibration were observed. Separation of them was successfully achieved using ideal band-pass filter and visualized in resultant movies, too. The observed ultrasonic waves were characterized and their respective speeds were measured by applying 2-D FFT. The C-scan method, combined with different digital signal processing techniques, was proved to be an very effective methodology to learn the behavior of chips under laser excitation. This general procedure can be

  13. Silanization of silica and glass slides for DNA microarrays by impregnation and gas phase protocols: A comparative study

    International Nuclear Information System (INIS)

    Phaner-Goutorbe, Magali; Dugas, Vincent; Chevolot, Yann; Souteyrand, Eliane

    2011-01-01

    Surface immobilization of oligonucleotide probes (oligoprobes) is a key issue in the development of DNA-chips. The immobilization protocol should guarantee good availability of the probes, low non-specific adsorption and reproducibility. We have previously reported a silanization protocol with tert-butyl-11-(dimethylamino)silylundecanoate performed by impregnation (Impregnation Protocol, IP) of silica substrates from dilute silane solutions, leading to surfaces bearing carboxylic groups. In this paper, the Impregnation protocol is compared with a Gas phase Protocol (GP) which is more suited to industrial requirements such as reliable and robust processing, cost efficiency, etc.... The morphology of the oligoprobe films at the nanoscale (characterized by Atomic Force Microscopy) and the reproducibility of subsequent oligoprobes immobilization steps have been investigated for the two protocols on thermal silica (Si/SiO 2 ) and glass slide substrates. IP leads to smooth surfaces whereas GP induces the formation of islands features suggesting a non-continuous silane layer. The reproducibility of the overall surface layer (18.75 mm 2 ) has been evaluated through the covalent immobilization of a fluorescent oligoprobes. Average fluorescent signals of 6 (a.u.) and 4 (a.u.) were observed for IP and GP, respectively, with a standard deviation of 1 for both protocols. Thus, despite a morphological difference of the silane layer at the nanometer scale, the density of the immobilized probes remained similar.

  14. An On-Chip interconnect and protocol stack for multiple communication paradigms and programming models

    NARCIS (Netherlands)

    Hansson, A.; Goossens, Kees

    2009-01-01

    A growing number of applications, with diverse requirements, are integrated on the same System on Chip (SoC) in the form of hardware and software Intellectual Property (IP). The diverse requirements, coupled with the IPs being developed by unrelated design teams, lead to multiple communication

  15. An on-chip interconnect and protocol stack for multiple communication paradigms and programming models

    NARCIS (Netherlands)

    Hansson, M.A.; Goossens, K.G.W.

    2009-01-01

    A growing number of applications, with diverse requirements, are integrated on the same System on Chip (SoC) in the form of hardware and software Intellectual Property (IP). The diverse requirements, coupled with the IPs being developed by unrelated design teams, lead to multiple communication

  16. On-chip real-time single-copy polymerase chain reaction in picoliter droplets

    Energy Technology Data Exchange (ETDEWEB)

    Beer, N R; Hindson, B; Wheeler, E; Hall, S B; Rose, K A; Kennedy, I; Colston, B

    2007-04-20

    The first lab-on-chip system for picoliter droplet generation and PCR amplification with real-time fluorescence detection has performed PCR in isolated droplets at volumes 10{sup 6} smaller than commercial real-time PCR systems. The system utilized a shearing T-junction in a silicon device to generate a stream of monodisperse picoliter droplets that were isolated from the microfluidic channel walls and each other by the oil phase carrier. An off-chip valving system stopped the droplets on-chip, allowing them to be thermal cycled through the PCR protocol without droplet motion. With this system a 10-pL droplet, encapsulating less than one copy of viral genomic DNA through Poisson statistics, showed real-time PCR amplification curves with a cycle threshold of {approx}18, twenty cycles earlier than commercial instruments. This combination of the established real-time PCR assay with digital microfluidics is ideal for isolating single-copy nucleic acids in a complex environment.

  17. Data transmission protocol for Pi-of-the-Sky cameras

    Science.gov (United States)

    Uzycki, J.; Kasprowicz, G.; Mankiewicz, M.; Nawrocki, K.; Sitek, P.; Sokolowski, M.; Sulej, R.; Tlaczala, W.

    2006-10-01

    The large amount of data collected by the automatic astronomical cameras has to be transferred to the fast computers in a reliable way. The method chosen should ensure data streaming in both directions but in nonsymmetrical way. The Ethernet interface is very good choice because of its popularity and proven performance. However it requires TCP/IP stack implementation in devices like cameras for full compliance with existing network and operating systems. This paper describes NUDP protocol, which was made as supplement to standard UDP protocol and can be used as a simple-network protocol. The NUDP does not need TCP protocol implementation and makes it possible to run the Ethernet network with simple devices based on microcontroller and/or FPGA chips. The data transmission idea was created especially for the "Pi of the Sky" project.

  18. Study of cutting speed on surface roughness and chip formation when machining nickel-based alloy

    International Nuclear Information System (INIS)

    Khidhir, Basim A.; Mohamed, Bashir

    2010-01-01

    Nickel- based alloy is difficult-to-machine because of its low thermal diffusive property and high strength at higher temperature. The machinability of nickel- based Hastelloy C-276 in turning operations has been carried out using different types of inserts under dry conditions on a computer numerical control (CNC) turning machine at different stages of cutting speed. The effects of cutting speed on surface roughness have been investigated. This study explores the types of wear caused by the effect of cutting speed on coated and uncoated carbide inserts. In addition, the effect of burr formation is investigated. The chip burr is found to have different shapes at lower speeds. Triangles and squares have been noticed for both coated and uncoated tips as well. The conclusion from this study is that the transition from thick continuous chip to wider discontinuous chip is caused by different types of inserts. The chip burr has a significant effect on tool damage starting in the line of depth-of-cut. For the coated insert tips, the burr disappears when the speed increases to above 150 m/min with the improvement of surface roughness; increasing the speed above the same limit for uncoated insert tips increases the chip burr size. The results of this study showed that the surface finish of nickel-based alloy is highly affected by the insert type with respect to cutting speed changes and its effect on chip burr formation and tool failure

  19. A microfluidic chip for electrochemical conversions in drug metabolism studies

    NARCIS (Netherlands)

    Odijk, Mathieu; Baumann, A.; Lohmann, W.; van den Brink, Floris Teunis Gerardus; Olthuis, Wouter; Karst, U.; van den Berg, Albert

    2009-01-01

    We have designed a microfluidic microreactor chip for electrochemical conversion of analytes, containing a palladium reference electrode and platinum working and counter electrodes. The counter electrode is placed in a separate side-channel on chip to prevent unwanted side-products appearing in the

  20. Flip chip assembly of thinned chips for hybrid pixel detector applications

    CERN Document Server

    Fritzsch, T; Woehrmann, M; Rothermund, M; Huegging, F; Ehrmann, O; Oppermann, H; Lang, K.D

    2014-01-01

    There is a steady trend to ultra-thin microelectronic devices. Especially for future particle detector systems a reduced readout chip thickness is required to limit the loss of tracking precision due to scattering. The reduction of silicon thickness is performed at wafer level in a two-step thinning process. To minimize the risk of wafer breakage the thinned wafer needs to be handled by a carrier during the whole process chain of wafer bumping. Another key process is the flip chip assembly of thinned readout chips onto thin sensor tiles. Besides the prevention of silicon breakage the minimization of chip warpage is one additional task for a high yield and reliable flip chip process. A new technology using glass carrier wafer will be described in detail. The main advantage of this technology is the combination of a carrier support during wafer processing and the chip support during flip chip assembly. For that a glass wafer is glue-bonded onto the backside of the thinned readout chip wafer. After the bump depo...

  1. Study on VCSEL laser heating chip in nuclear magnetic resonance gyroscope

    Science.gov (United States)

    Liang, Xiaoyang; Zhou, Binquan; Wu, Wenfeng; Jia, Yuchen; Wang, Jing

    2017-10-01

    In recent years, atomic gyroscope has become an important direction of inertial navigation. Nuclear magnetic resonance gyroscope has a stronger advantage in the miniaturization of the size. In atomic gyroscope, the lasers are indispensable devices which has an important effect on the improvement of the gyroscope performance. The frequency stability of the VCSEL lasers requires high precision control of temperature. However, the heating current of the laser will definitely bring in the magnetic field, and the sensitive device, alkali vapor cell, is very sensitive to the magnetic field, so that the metal pattern of the heating chip should be designed ingeniously to eliminate the magnetic field introduced by the heating current. In this paper, a heating chip was fabricated by MEMS process, i.e. depositing platinum on semiconductor substrates. Platinum has long been considered as a good resistance material used for measuring temperature The VCSEL laser chip is fixed in the center of the heating chip. The thermometer resistor measures the temperature of the heating chip, which can be considered as the same temperature of the VCSEL laser chip, by turning the temperature signal into voltage signal. The FPGA chip is used as a micro controller, and combined with PID control algorithm constitute a closed loop control circuit. The voltage applied to the heating resistor wire is modified to achieve the temperature control of the VCSEL laser. In this way, the laser frequency can be controlled stably and easily. Ultimately, the temperature stability can be achieved better than 100mK.

  2. On-chip concentration of bacteria using a 3D dielectrophoretic chip and subsequent laser-based DNA extraction in the same chip

    International Nuclear Information System (INIS)

    Cho, Yoon-Kyoung; Kim, Tae-hyeong; Lee, Jeong-Gun

    2010-01-01

    We report the on-chip concentration of bacteria using a dielectrophoretic (DEP) chip with 3D electrodes and subsequent laser-based DNA extraction in the same chip. The DEP chip has a set of interdigitated Au post electrodes with 50 µm height to generate a network of non-uniform electric fields for the efficient trapping by DEP. The metal post array was fabricated by photolithography and subsequent Ni and Au electroplating. Three model bacteria samples (Escherichia coli, Staphylococcus epidermidis, Streptococcus mutans) were tested and over 80-fold concentrations were achieved within 2 min. Subsequently, on-chip DNA extraction from the concentrated bacteria in the 3D DEP chip was performed by laser irradiation using the laser-irradiated magnetic bead system (LIMBS) in the same chip. The extracted DNA was analyzed with silicon chip-based real-time polymerase chain reaction (PCR). The total process of on-chip bacteria concentration and the subsequent DNA extraction can be completed within 10 min including the manual operation time.

  3. Chips 2020

    CERN Document Server

    2016-01-01

    The release of this second volume of CHIPS 2020 coincides with the 50th anniversary of Moore’s Law, a critical year marked by the end of the nanometer roadmap and by a significantly reduced annual rise in chip performance. At the same time, we are witnessing a data explosion in the Internet, which is consuming 40% more electrical power every year, leading to fears of a major blackout of the Internet by 2020. The messages of the first CHIPS 2020, published in 2012, concerned the realization of quantum steps for improving the energy efficiency of all chip functions. With this second volume, we review these messages and amplify upon the most promising directions: ultra-low-voltage electronics, nanoscale monolithic 3D integration, relevant-data, brain- and human-vision-inspired processing, and energy harvesting for chip autonomy. The team of authors, enlarged by more world leaders in low-power, monolithic 3D, video, and Silicon brains, presents new vistas in nanoelectronics, promising  Moore-like exponential g...

  4. A software defined RTU multi-protocol automatic adaptation data transmission method

    Science.gov (United States)

    Jin, Huiying; Xu, Xingwu; Wang, Zhanfeng; Ma, Weijun; Li, Sheng; Su, Yong; Pan, Yunpeng

    2018-02-01

    Remote terminal unit (RTU) is the core device of the monitor system in hydrology and water resources. Different devices often have different communication protocols in the application layer, which results in the difficulty in information analysis and communication networking. Therefore, we introduced the idea of software defined hardware, and abstracted the common feature of mainstream communication protocols of RTU application layer, and proposed a uniformed common protocol model. Then, various communication protocol algorithms of application layer are modularized according to the model. The executable codes of these algorithms are labeled by the virtual functions and stored in the flash chips of embedded CPU to form the protocol stack. According to the configuration commands to initialize the RTU communication systems, it is able to achieve dynamic assembling and loading of various application layer communication protocols of RTU and complete the efficient transport of sensor data from RTU to central station when the data acquisition protocol of sensors and various external communication terminals remain unchanged.

  5. Tin-Silver Alloys for Flip-Chip Bonding Studied with a Rotating Cylinder Electrode

    DEFF Research Database (Denmark)

    Tang, Peter Torben; Pedersen, E.H.; Bech-Nielsen, G.

    1999-01-01

    Electrodeposition of solder for flip-chip bonding is studied in the form of a pyrophosphate/iodide tin-silver alloy bath. The objective is to obtain a uniform alloy composition, with 3.8 At.% silver, over a larger area. This specific alloy will provide an eutectic solder melting at 221°C (or 10°C...... photoresist, have shown a stable and promising alternative to pure tin and tin-lead alloys for flip-chip bonding applications....

  6. Optimizing the high-resolution manometry (HRM) study protocol.

    Science.gov (United States)

    Patel, A; Ding, A; Mirza, F; Gyawali, C P

    2015-02-01

    Intolerance of the esophageal manometry catheter may prolong high-resolution manometry (HRM) studies and increase patient distress. We assessed the impact of obtaining the landmark phase at the end of the study when the patient has acclimatized to the HRM catheter. 366 patients (mean age 55.4 ± 0.8 years, 62.0% female) undergoing esophageal HRM over a 1-year period were studied. The standard protocol consisted of the landmark phase, 10 5 mL water swallows 20-30 s apart, and multiple rapid swallows where 4-6 2 mL swallows were administered in rapid succession. The modified protocol consisted of the landmark phase at the end of the study after test swallows. Study duration, technical characteristics, indications, and motor findings were compared between standard and modified protocols. Of the 366 patients, 89.6% underwent the standard protocol (study duration 12.9 ± 0.3 min). In 10.4% with poor catheter tolerance undergoing the modified protocol, study duration was significantly longer (15.6 ± 1.0 min, p = 0.004) despite similar duration of study maneuvers. Only elevated upper esophageal sphincter basal pressures at the beginning of the study segregated modified protocol patients. The 95th percentile time to landmark phase in the standard protocol patients was 6.1 min; as many as 31.4% of modified protocol patients could not obtain their first study maneuver within this period (p = 0.0003). Interpretation was not impacted by shifting the landmark phase to the end of the study. Modification of the HRM study protocol with the landmark phase obtained at the end of the study optimizes study duration without compromising quality. © 2014 John Wiley & Sons Ltd.

  7. Lab-on a-Chip

    Science.gov (United States)

    1999-01-01

    Labs on chips are manufactured in many shapes and sizes and can be used for numerous applications, from medical tests to water quality monitoring to detecting the signatures of life on other planets. The eight holes on this chip are actually ports that can be filled with fluids or chemicals. Tiny valves control the chemical processes by mixing fluids that move in the tiny channels that look like lines, connecting the ports. Scientists at NASA's Marshall Space Flight Center (MSFC) in Huntsville, Alabama designed this chip to grow biological crystals on the International Space Station (ISS). Through this research, they discovered that this technology is ideally suited for solving the challenges of the Vision for Space Exploration. For example, thousands of chips the size of dimes could be loaded on a Martian rover looking for biosignatures of past or present life. Other types of chips could be placed in handheld devices used to monitor microbes in water or to quickly conduct medical tests on astronauts. The portable, handheld Lab-on-a Chip Application Development Portable Test System (LOCAD-PTS) made its debut flight aboard Discovery during the STS-116 mission launched December 9, 2006. The system allowed crew members to monitor their environment for problematic contaminants such as yeast, mold, and even E.coli, and salmonella. Once LOCAD-PTS reached the ISS, the Marshall team continued to manage the experiment, monitoring the study from a console in the Payload Operations Center at MSFC. The results of these studies will help NASA researchers refine the technology for future Moon and Mars missions. (NASA/MSFC/D.Stoffer)

  8. Performance Analysis of an Optical CDMA MAC Protocol With Variable-Size Sliding Window

    Science.gov (United States)

    Mohamed, Mohamed Aly A.; Shalaby, Hossam M. H.; Abdel-Moety El-Badawy, El-Sayed

    2006-10-01

    A media access control protocol for optical code-division multiple-access packet networks with variable length data traffic is proposed. This protocol exhibits a sliding window with variable size. A model for interference-level fluctuation and an accurate analysis for channel usage are presented. Both multiple-access interference (MAI) and photodetector's shot noise are considered. Both chip-level and correlation receivers are adopted. The system performance is evaluated using a traditional average system throughput and average delay. Finally, in order to enhance the overall performance, error control codes (ECCs) are applied. The results indicate that the performance can be enhanced to reach its peak using the ECC with an optimum number of correctable errors. Furthermore, chip-level receivers are shown to give much higher performance than that of correlation receivers. Also, it has been shown that MAI is the main source of signal degradation.

  9. Strong Authentication Protocol based on Java Crypto Chip as a Secure Element

    Directory of Open Access Journals (Sweden)

    Majid Mumtaz

    2016-10-01

    Full Text Available Smart electronic devices and gadgets and their applications are becoming more and more popular. Most of those devices and their applications handle personal, financial, medical and other sensitive data that require security and privacy protection. In this paper we describe one aspect of such protection – user authentication protocol based on the use of X.509 certificates. The system uses Public Key Infrastructure (PKI, challenge/response protocol, mobile proxy servers, and Java cards with crypto capabilities used as a Secure Element. Innovative design of the protocol, its implementation, and evaluation results are described. In addition to end-user authentication, the described solution also supports the use of X.509 certificates for additional security services – confidentiality, integrity, and non-repudiation of transactions and data in an open network environment. The system uses Application Programming Interfaces (APIs to access Java cards functions and credentials that can be used as add-ons to enhance any mobile application with security features and services.

  10. Influence of passivation process on chip performance

    NARCIS (Netherlands)

    Lu, J.; Kovalgin, Alexeij Y.; Schmitz, Jurriaan

    2009-01-01

    In this work, we have studied the performance of CMOS chips before and after a low temperature post-processing step. In order to prevent damage to the IC chips by the post-processing steps, a first passivation layers is needed on top of the IC chips. Two different passivation layer deposition

  11. Wood chip delivery and research project at Mikkeli region

    International Nuclear Information System (INIS)

    Saksa, T.; Auvinen, P.

    1995-01-01

    In 1994, a large-scale energywood production chain was started as a co-operation project by the Mikkeli city forest office and local forestry societies. Over 60 000 m 3 (about 46 000 MWh of energy) of forest processed chips were delivered to Pursiala heat and power plant in Mikkeli. About 60 % of these chips was whole tree chips from improvement cuttings of young forest stands and the rest was logging waste chips from regeneration cutting areas. The average total delivery costs of forest processed chips after reduction of energywood and other subsidies were approximately 51 FIM/m 3 (68 FIM/MWh) for the whole tree chips and 40 FIM/m 3 (53 FIM/MWh) for logging waste chips. The delivery costs of wood chips could compete with those of fuel peat only in the most favourable cases. The resources of forest processed chips were studied on the basis of forestry plans. According to the study, there is enough raw material for permanent, large-scale delivery of forest processed chips (up to 250 000 m 3 /a) in the forests located at a distance of under 40 road kilometers from the Pursiala heat and power plant. The following project stages will involve further development of the wood chip delivery chain logistics, as well as improvement of logging and chipping equipment and methods in energywood and logging waste production. Also the effects of wood energy production on the economy and environment of the whole Mikkeli region will be studied. (author)

  12. Comprehensive Study of Microgel Electrode for On-Chip Electrophoretic Cell Sorting

    Science.gov (United States)

    Hattori, Akihiro; Yasuda, Kenji

    2010-06-01

    We have developed an on-chip cell sorting system and microgel electrode for applying electrostatic force in microfluidic pathways in the chip. The advantages of agarose electrodes are 1) current-driven electrostatic force generation, 2) stability against pH change and chemicals, and 3) no bubble formation caused by electrolysis. We examined the carrier ion type and concentration dependence of microgel electrode impedance, and found that CoCl2 has less than 1/10 of the impedance from NaCl, and the reduction of the impedance of NaCl gel electrode was plateaued at 0.5 M. The structure control of the microgel electrode exploiting the surface tension of sol-state agarose was also introduced. The addition of 1% (w/v) trehalose into the microgel electrode allowed the frozen storage of the microgel electrode chip. The experimental results demonstrate the potential of our system and microgel electrode for practical applications in microfluidic chips.

  13. Study protocol

    DEFF Research Database (Denmark)

    Smith, Benjamin E; Hendrick, Paul; Bateman, Marcus

    2017-01-01

    avoidance behaviours, catastrophising, self-efficacy, sport and leisure activity participation, and general quality of life. Follow-up will be 3 and 6 months. The analysis will focus on descriptive statistics and confidence intervals. The qualitative components will follow a thematic analysis approach....... DISCUSSION: This study will evaluate the feasibility of running a definitive large-scale trial on patients with patellofemoral pain, within the NHS in the UK. We will identify strengths and weaknesses of the proposed protocol and the utility and characteristics of the outcome measures. The results from...... this study will inform the design of a multicentre trial. TRIAL REGISTRATION: ISRCTN35272486....

  14. Lab-On-a-Chip Application Development (LOCAD): Bridging Technology Readiness for Exploration

    Science.gov (United States)

    Spearing, Scott F.; Jenkins, Andy

    2004-01-01

    At Marshall Space Flight Center we have established a capability to investigate the use of microfluidics for space flight. The Lab-On-a-Chip Application Development (LOCAD) team has created a program for advancing Technology Readiness Levels (TRL) of 1 and 2 to TRL 6 and 7, quickly and economically for Lab-On-a-Chip (LOC) applications. Scientists and engineers can utilize LOCAD'S process to efficiently learn about microfluidics and determine if microfluidics is applicable to their needs. Once the applicability has been determined, LOCAD can then perform tests to develop the new fluidic protocols which are different from macro-scale chemical reaction protocols. With this information new micro-fluidic devices can be created and tested. Currently, LOCAD is focused on using microfluidics for both Environmental Monitoring & Control, and Medical Systems. Eventually, handheld portable units utilizing LOC technology will perform rapid tests to determine water quality, and microbial contamination levels. Since LOC technology is drastically reduced in physical size, it thereby reduces power, weight, volume, and sample requirements, a big advantage considering the resource constraints associated with spaceflight. Another one of LOCAD's current activities is the development of a microfluidic system to aid in the search for life on Mars.

  15. Management of Chronic Periodontitis Using Chlorhexidine Chip and Diode Laser-A Clinical Study

    Science.gov (United States)

    Ambooken, Majo; Mathew, Jayan Jacob; Issac, Annie Valayil; Kunju, Ajithkumar Parachalil; Parameshwaran, Renjith Athirkandathil

    2016-01-01

    Introduction The use of adjuncts like chlorhexidine local delivery and diode laser decontamination have been found to improve the clinical outcomes of scaling and root planing in non-surgical periodontal therapy in patients with chronic periodontitis. Aim To evaluate the effects of diode laser and chlorhexidine chip as adjuncts to scaling and root planing in the management of chronic periodontitis. The objective is to evaluate the outcome of chlorhexidine chip and diode laser as adjuncts to scaling and root planing on clinical parameters like Plaque Index, Gingival Index, probing pocket depth and clinical attachment level. Study and Design Department of Periodontics. Randomized clinical trial with split mouth design. Materials and Methods Fifteen chronic periodontitis patients having a probing pocket depth of 5mm-7mm on at least one interproximal site in each quadrant of the mouth were included in the study. After initial treatment, four sites in each patient were randomly subjected to scaling and root planing (control), chlorhexidine chip application (CHX chip group), diode laser (810 nm) decontamination (Diode laser group) or combination of both (Diode laser and chip group). Plaque Index (PI), Gingival Index (GI), probing pocket depth (PPD) and clinical attachment level (CAL) were assessed at baseline, one month and three months. Statistical analysis Results were statistically analysed using paired T test, one-way ANOVA, Tukey’s HSD test and repeated measure ANOVA. Results Post-treatment, the test and control sites showed a statistically significant reduction in PI, GI, PPD, and CAL. After three months, a mean PPD reduction of 1.47±0.52 mm in control group, 1.40±0.83 mm in diode laser group, 2.67±0.62 mm in CHX group, and 2.80± 0.77 mm in combination group was seen. The mean gain in CAL were 1.47±0.52 mm in the control group, 1.40±0.83 mm in diode laser group, 2.67± 0.49 mm in CHX group and 2.67± 0.82 mm in combination group respectively. The

  16. Comparative studies on storage and drying of chips and chunks in Norway

    Energy Technology Data Exchange (ETDEWEB)

    Gjoelsjoe, S. (Norwegian Forest Research Inst. (Norway))

    1988-11-01

    Knowledge of sporulation and alteration in moisture content and dry-matter content is essential when trying to determine optimal conditions for storage of wood fuel. The object of this experiment has been to study the progression of these variables in wood fuel of varying sizes. The material used was debranched stemwood of birch. The wood was comminuted up and stored in three different sizes. The sizes were chips (length approx. 3 cm), chunkwood (approx. 8 cm) and firewood (approx. 15 cm). The fuelwood was stored in bines of 10 m{sup 3} with netting floor and netting walls. Six of the bins were covered, the remaining six were without cover. The highest temperature increase was found in chips, particularly during the first stages of storage when temperature reached approximately 30 C. The other fuel sizes had temperature close to ambient temperature. At the start of the test, moisture content was approximately 40 %. By the end of the test the moisture content was below 20% for firewood and chunkwood under cover. The moisture was measured 50 cm from the top and 50 cm from the sidewall of the bin. Whilst chips without cover had a moisture content of more than 60%. Storage under cover resulted in a higher reduction of moisture content than storage without cover. The smaller sizes exhibited the greatest difference in moisture content. The highest dry-matter loss during the storage time was found in chips stored under cover, approximately 1.2% per month. Dry-matter loss was lowest in firewood stored under cover 0.07% per month. Dry-matter loss decreased with increasing size. Spores and dust particles had the highest concentrations in chips and lowest in firewood. (12 refs., 10 figs., 8 tabs.) (au).

  17. Usability of human Infinium MethylationEPIC BeadChip for mouse DNA methylation studies.

    Science.gov (United States)

    Needhamsen, Maria; Ewing, Ewoud; Lund, Harald; Gomez-Cabrero, David; Harris, Robert Adam; Kular, Lara; Jagodic, Maja

    2017-11-15

    The advent of array-based genome-wide DNA methylation methods has enabled quantitative measurement of single CpG methylation status at relatively low cost and sample input. Whereas the use of Infinium Human Methylation BeadChips has shown great utility in clinical studies, no equivalent tool is available for rodent animal samples. We examined the feasibility of using the new Infinium MethylationEPIC BeadChip for studying DNA methylation in mouse. In silico, we identified 19,420 EPIC probes (referred as mEPIC probes), which align with a unique best alignment score to the bisulfite converted reference mouse genome mm10. Further annotation revealed that 85% of mEPIC probes overlapped with mm10.refSeq genes at different genomic features including promoters (TSS1500 and TSS200), 1st exons, 5'UTRs, 3'UTRs, CpG islands, shores, shelves, open seas and FANTOM5 enhancers. Hybridization of mouse samples to Infinium Human MethylationEPIC BeadChips showed successful measurement of mEPIC probes and reproducibility between inter-array biological replicates. Finally, we demonstrated the utility of mEPIC probes for data exploration such as hierarchical clustering. Given the absence of cost and labor convenient genome-wide technologies in the murine system, our findings show that the Infinium MethylationEPIC BeadChip platform is suitable for investigation of the mouse methylome. Furthermore, we provide the "mEPICmanifest" with genomic features, available to users of Infinium Human MethylationEPIC arrays for mouse samples.

  18. Chip-to-Chip Half Duplex Spiking Data Communication over Power Supply Rails

    Science.gov (United States)

    Hashida, Takushi; Nagata, Makoto

    Chip-to-chip serial data communication is superposed on power supply over common Vdd/Vss connections through chip, package, and board traces. A power line transceiver demonstrates half duplex spiking communication at more than 100Mbps. A pair of transceivers consumes 1.35mA from 3.3V, at 130Mbps. On-chip power line LC low pass filter attenuates pseudo-differential communication spikes by 30dB, purifying power supply current for internal circuits. Bi-directional spiking communication was successfully examined in a 90-nm CMOS prototype setup of on-chip waveform capturing. A micro controller forwards clock pulses to and receives data streams from a comparator based waveform capturer formed on a different chip, through a single pair of power and ground traces. The bit error rate is small enough not to degrade waveform acquisition capability, maintaining the spurious free dynamic range of higher than 50dB.

  19. Extraction protocols for orthodontic treatment: A retrospective study

    Directory of Open Access Journals (Sweden)

    Vaishnevi N Thirunavukkarasu

    2016-01-01

    Full Text Available Background and Objectives: Various extraction protocols have been followed for successful orthodontic treatment. The purpose of this study was to evaluate the extraction protocols in patients who had previously undergone orthodontic treatment and also who had reported for continuing orthodontic treatment from other clinics. Materials and Methods: One hundred thirty eight patients who registered for orthodontic treatment at the Faculty of Dentistry were divided into 10 extraction protocols based on the Orthodontic treatment protocol given by Janson et al. and were evaluated for statistical significance. Results: The descriptive statistics of the study revealed a total of 40 (29% patients in protocol 1, 43 (31.2% in protocol 2, 18 (13% in protocol 3, 16 (11.6% in protocol 5, and 12 (8.7% in Type 3 category of protocol 9. The Type 3 category in protocol 9 was statistically significant compared to other studies. Midline shift and collapse of the arch form were noticed in these individuals. Conclusion: Extraction of permanent teeth such as canine and lateral incisors without rational reasons could have devastating consequences on the entire occlusion. The percentage of cases wherein extraction of permanent teeth in the crowded region was adopted as a treatment option instead of orthodontic treatment is still prevalent in dental practice. The shortage of orthodontists in Malaysia, the long waiting period, and lack of subjective need for orthodontic treatment at an earlier age group were the reasons for the patient's to choose extraction of the mal-aligned teeth such as the maxillary canine or maxillary lateral incisors.

  20. A proposed holistic approach to on-chip, off-chip, test, and package interconnections

    Science.gov (United States)

    Bartelink, Dirk J.

    1998-11-01

    The term interconnection has traditionally implied a `robust' connection from a transistor or a group of transistors in an IC to the outside world, usually a PC board. Optimum system utilization is done from outside the IC. As an alternative, this paper addresses `unimpeded' transistor-to-transistor interconnection aimed at reaching the high circuit densities and computational capabilities of neighboring IC's. In this view, interconnections are not made to some human-centric place outside the IC world requiring robustness—except for system input and output connections. This unimpeded interconnect style is currently available only through intra-chip signal traces in `system-on-a-chip' implementations, as exemplified by embedded DRAMs. Because the traditional off-chip penalty in performance and wiring density is so large, a merging of complex process technologies is the only option today. It is suggested that, for system integration to move forward, the traditional robustness requirement inherited from conventional packaging interconnect and IC manufacturing test must be discarded. Traditional system assembly from vendor parts requires robustness under shipping, inspection and assembly. The trend toward systems on a chip signifies willingness by semiconductor companies to design and fabricate whole systems in house, so that `in-house' chip-to-chip assembly is not beyond reach. In this scenario, bare chips never leave the controlled environment of the IC fabricator while the two major contributors to off-chip signal penalty, ESD protection and the need to source a 50-ohm test head, are avoided. With in-house assembly, ESD protection can be eliminated with the precautions already familiar in plasma etching. Test interconnection impacts the fundamentals of IC manufacturing, particularly with clock speeds approaching 1GHz, and cannot be an afterthought. It should be an integral part of the chip-to-chip interconnection bandwidth optimization, because—as we must

  1. A scalable single-chip multi-processor architecture with on-chip RTOS kernel

    NARCIS (Netherlands)

    Theelen, B.D.; Verschueren, A.C.; Reyes Suarez, V.V.; Stevens, M.P.J.; Nunez, A.

    2003-01-01

    Now that system-on-chip technology is emerging, single-chip multi-processors are becoming feasible. A key problem of designing such systems is the complexity of their on-chip interconnects and memory architecture. It is furthermore unclear at what level software should be integrated. An example of a

  2. Autogenous Partial Bone Chip Grafting on the Exposed Inferior Alveolar Nerve After Cystic Enucleation.

    Science.gov (United States)

    Seo, Mi Hyun; Eo, Mi Young; Cho, Yun Ju; Kim, Soung Min; Lee, Suk Keun

    2018-03-01

    This prospective study evaluated the clinical effectiveness of the new approach of partial autogenous bone chip grafts for the treatment of mandibular cystic lesions related to the inferior alveolar nerve (IAN). A total of 38 patients treated for mandibular cysts or benign tumors were included in this prospective study and subsequently divided into 3 groups depending on the bone grafting method used: cystic enucleation without a bone graft (group 1), partial bone chip graft covering the exposed IAN (group 2), and autogenous bone graft covering the entire defect (group 3). We evaluated the symptoms, clinical signs, and radiographic changes using dental panorama preoperatively, immediate postoperatively, and at 1, 3, 6, and 12 months postoperatively. Radiographic densities were compared using Adobe Photoshop CS5 (Adobe Systems Inc., San Jose, CA). Repeated measures analysis of variance was used for statistical evaluation with SPSS 22.0 (SPSS Inc, Chicago, IL), and P < 0.05 was considered statistically significant.Radiopacities were the most increased at 1 year postoperative in group 3; groups 2 and 3 did not show statistically significant differences, whereas groups 1 and 3 were statistically significant. In terms of radiographic bone healing with clinical regeneration of the exposed IAN, healing occurred in all patients, although the best healing was achieved in group 2.This autogenous partial bone chip grafting procedure to cover the exposed IAN is suggested as a new surgical protocol for the treatment of cystic lesions associated with the IAN.

  3. Efficient generation of single and entangled photons on a silicon photonic integrated chip

    International Nuclear Information System (INIS)

    Mower, Jacob; Englund, Dirk

    2011-01-01

    We present a protocol for generating on-demand, indistinguishable single photons on a silicon photonic integrated chip. The source is a time-multiplexed spontaneous parametric down-conversion element that allows optimization of single-photon versus multiphoton emission while realizing high output rate and indistinguishability. We minimize both the scaling of active elements and the scaling of active element loss with multiplexing. We then discuss detection strategies and data processing to further optimize the procedure. We simulate an improvement in single-photon-generation efficiency over previous time-multiplexing protocols, assuming existing fabrication capabilities. We then apply this system to generate heralded Bell states. The generation efficiency of both nonclassical states could be increased substantially with improved fabrication procedures.

  4. Chip compacting press; Jido kirikuzu asshukuki

    Energy Technology Data Exchange (ETDEWEB)

    Oura, K. [Yuken Kogyo Co. Ltd., Kanagawa (Japan)

    1998-08-15

    The chips exhausted from various machine tools are massy, occupy much space and make working environment worse by staying added cutting oil to lower part. The chips are exhausted as a result of machining and have not constant quality. Even if used material is same the chips have various shapes and properties by kinds and machining methods of used machine tools, and are troublesome materials from a standpoint of their treatment. Pressing and solidification of the chips have frequently been tried. A chip compacting press introduced in this paper, a relatively cheap chip compacting press aimed for relatively small scale chip treatment, and has such characteristics and effects as follows. Chips are pressed and solidified by each raw material, so fractional management can be easily conducted. As casting metal chips and curled chips of iron and aluminum can be pressed to about 1/3 to 1/5 and about 1/40, respectively, space saving can be conducted. Chip compacting pressing upgrades its transporting efficiency to make possible to reduce its transporting cost. As chip solidification controls its oxidation and most cutting oil are removed, chips are easy to recycle. 2 figs., 1 tab.

  5. Decoy-state BB84 protocol using space division multiplexing in silicon photonics

    DEFF Research Database (Denmark)

    Bacco, Davide; Ding, Yunhong; Dalgaard, Kjeld

    2017-01-01

    Quantum key distribution (QKD), a technique based on quantum physics, provides unconditional secure quantum keys to be shared between two or more clients (Alice and Bob) [1]. Most QKD systems are implemented in a point-to-point link using bulky and expensive devices. Consequently a large scale...... experiments have already demonstrated conventional binary QKD systems, using polarization and phase reference degrees of freedom [2, 3]. In this paper, we show the first silicon chip-to-chip decoy-state BB84 protocol based on spatial degrees of freedom (the cores of a multi-core fiber-MCF-). By tuning...... the superposition of the quantum state between cores, combined with a positive/negative phase relation. A train of weak coherent pulses (5 kHz repetition and 10 ns wide) are injected into the transmitter chip (Alice), where multiple variable optical attenuators (VOAs) are used to decrease the number of photons per...

  6. On-chip electrochromic micro display for a disposable bio-sensor chip

    Science.gov (United States)

    Zhu, Yanjun; Tsukamoto, Takashiro; Tanaka, Shuji

    2017-12-01

    This paper reports an on-chip electrochromic micro display made of polyaniline (PANi) which can be easily made on a CMOS chip. Micro-patterned PANi thin films were selectively deposited on pre-patterned microelectrodes by using electrodeposition. The optimum conditions for deposition and electrochromism were investigated. An 8-pixel on-chip micro display was made on a Si chip. The color of each PANi film could be independently but simultaneously controlled, which means any 1-byte digital data could be displayed on the display. The PANi display had a response time as fast as about 100 ms, which means the transfer data rate was as fast as 80 bits per second.

  7. Organs-on-a-chip: Current applications and consideration points for in vitro ADME-Tox studies.

    Science.gov (United States)

    Ishida, Seiichi

    2018-02-01

    Assay systems using in vitro cultured cells are increasingly applied for evaluation of the efficacy, safety, and toxicity of drug candidates. In vitro cell-based assays have two main applications in the drug discovery process: searching for a compound that is effective against the target disease (seed investigation) and confirmation of safety during use of the identified compounds (safety assessment). Currently available in vitro cell-based assays have been designed to evaluate the efficacy and toxicity in single organs, but the in vivo pharmacokinetics and pharmacodynamics of the administered drug candidates have not been considered. Thus, an evaluation system that interconnects cell culture units, one of which has appropriate drug metabolism activities and the other assesses the efficacy and toxicity of compounds, is needed. Accordingly, the in vitro ADME-Tox culture system known as organs-on-a-chip has been proposed. In this review, after introducing the organs-on-a-chip system, the evaluation of enterohepatic circulation and the gut-liver axis relationship will be presented as an example of the application of the organs-on-a-chip system for ADME studies based on inter-organ network. Additionally, the functions required for the organs-on-a-chip system and the necessity of standardization of cells mounted on the chip system will be discussed. Copyright © 2018 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  8. Least cost supply strategies for wood chips

    DEFF Research Database (Denmark)

    Möller, Bernd

    The abstract presents a study based on a geographical information system, which produce  cost-supply curves by location for forest woods chips in Denmark.......The abstract presents a study based on a geographical information system, which produce  cost-supply curves by location for forest woods chips in Denmark....

  9. Pixel detector readout chip

    CERN Multimedia

    1991-01-01

    Close-up of a pixel detector readout chip. The photograph shows an aera of 1 mm x 2 mm containing 12 separate readout channels. The entire chip contains 1000 readout channels (around 80 000 transistors) covering a sensitive area of 8 mm x 5 mm. The chip has been mounted on a silicon detector to detect high energy particles.

  10. Management of Chronic Periodontitis Using Chlorhexidine Chip and Diode Laser-A Clinical Study.

    Science.gov (United States)

    Jose, Kachapilly Arun; Ambooken, Majo; Mathew, Jayan Jacob; Issac, Annie Valayil; Kunju, Ajithkumar Parachalil; Parameshwaran, Renjith Athirkandathil

    2016-04-01

    The use of adjuncts like chlorhexidine local delivery and diode laser decontamination have been found to improve the clinical outcomes of scaling and root planing in non-surgical periodontal therapy in patients with chronic periodontitis. To evaluate the effects of diode laser and chlorhexidine chip as adjuncts to scaling and root planing in the management of chronic periodontitis. The objective is to evaluate the outcome of chlorhexidine chip and diode laser as adjuncts to scaling and root planing on clinical parameters like Plaque Index, Gingival Index, probing pocket depth and clinical attachment level. Department of Periodontics. Randomized clinical trial with split mouth design. Fifteen chronic periodontitis patients having a probing pocket depth of 5mm-7mm on at least one interproximal site in each quadrant of the mouth were included in the study. After initial treatment, four sites in each patient were randomly subjected to scaling and root planing (control), chlorhexidine chip application (CHX chip group), diode laser (810 nm) decontamination (Diode laser group) or combination of both (Diode laser and chip group). Plaque Index (PI), Gingival Index (GI), probing pocket depth (PPD) and clinical attachment level (CAL) were assessed at baseline, one month and three months. Results were statistically analysed using paired T test, one-way ANOVA, Tukey's HSD test and repeated measure ANOVA. Post-treatment, the test and control sites showed a statistically significant reduction in PI, GI, PPD, and CAL. After three months, a mean PPD reduction of 1.47±0.52 mm in control group, 1.40±0.83 mm in diode laser group, 2.67±0.62 mm in CHX group, and 2.80± 0.77 mm in combination group was seen. The mean gain in CAL were 1.47±0.52 mm in the control group, 1.40±0.83 mm in diode laser group, 2.67± 0.49 mm in CHX group and 2.67± 0.82 mm in combination group respectively. The differences in PPD reduction and CAL gain between control group and CHX chip and combination

  11. Preservation of forest wood chips

    Energy Technology Data Exchange (ETDEWEB)

    Kofman, P.D.; Thomsen, I.M.; Ohlsson, C.; Leer, E.; Ravn Schmidt, E.; Soerensen, M.; Knudsen, P.

    1999-01-01

    As part of the Danish Energy Research Programme on biomass utilisation for energy production (EFP), this project concerns problems connected to the handling and storing of wood chips. In this project, the possibility of preserving wood chips of the Norway Spruce (Picea Abies) is addressed, and the potential improvements by anaerobic storage are tested. Preservation of wood chips aims at reducing dry matter losses from extensive heating during storage and to reduce production of fungal spores. Fungal spores pose a health hazards to workers handling the chips. Further the producers of wood chips are interested in such a method since it would enable them to give a guarantee for the delivery of homogeneous wood chips also during the winter period. Three different types of wood chips were stored airtight and further one of these was stored in accordance with normal practise and use as reference. The results showed that airtight storage had a beneficial impact on the quality of the chips: no redistribution of moisture, low dry matter losses, unfavourable conditions for microbial activity of most fungi, and the promotion of yeasts instead of fungi with airborne spores. Likewise the firing tests showed that no combustion problems, and no increased risk to the environment or to the health of staff is caused by anaerobic storage of wood chips. In all, the tests of the anaerobic storage method of forest wood chips were a success and a large-scale test of the method will be carried out in 1999. (au)

  12. Mac protocols for wireless sensor network (wsn): a comparative study

    International Nuclear Information System (INIS)

    Arshad, J.; Akram, Q.; Saleem, Y.

    2014-01-01

    Data communication between nodes is carried out under Medium Access Control (MAC) protocol which is defined at data link layer. The MAC protocols are responsible to communicate and coordinate between nodes according to the defined standards in WSN (Wireless Sensor Networks). The design of a MAC protocol should also address the issues of energy efficiency and transmission efficiency. There are number of MAC protocols that exist in the literature proposed for WSN. In this paper, nine MAC protocols which includes S-MAC, T-MAC, Wise-MAC, Mu-MAC, Z-MAC, A-MAC, D-MAC, B-MAC and B-MAC+ for WSN have been explored, studied and analyzed. These nine protocols are classified in contention based and hybrid (combination of contention and schedule based) MAC protocols. The goal of this comparative study is to provide a basis for MAC protocols and to highlight different mechanisms used with respect to parameters for the evaluation of energy and transmission efficiency in WSN. This study also aims to give reader a better understanding of the concepts, processes and flow of information used in these MAC protocols for WSN. A comparison with respect to energy reservation scheme, idle listening avoidance, latency, fairness, data synchronization, and throughput maximization has been presented. It was analyzed that contention based MAC protocols are less energy efficient as compared to hybrid MAC protocols. From the analysis of contention based MAC protocols in term of energy consumption, it was being observed that protocols based on preamble sampling consume lesser energy than protocols based on static or dynamic sleep schedule. (author)

  13. Real-time studies of chemical reactions in lab-on-a-chip devices

    NARCIS (Netherlands)

    Brivio, M.

    2005-01-01

    The realization of a lab-on-a-chip system in which chemical reactions are carried out in a continuous flow mode and monitored on-line by a suitable analytical technique is the main topic of this thesis. Two types of a lab-on-a-chip were realized, both using mass spectrometry (MS) as the on-line

  14. The impact of CHIP premium increases on insurance outcomes among CHIP eligible children.

    Science.gov (United States)

    Nikolova, Silviya; Stearns, Sally

    2014-03-03

    Within the United States, public insurance premiums are used both to discourage private health policy holders from dropping coverage and to reduce state budget costs. Prior research suggests that the odds of having private coverage and being uninsured increase with increases in public insurance premiums. The aim of this paper is to test effects of Children's Health Insurance Program (CHIP) premium increases on public insurance, private insurance, and uninsurance rates. The fact that families just below and above a state-specific income cut-off are likely very similar in terms of observable and unobservable characteristics except the premium contribution provides a natural experiment for estimating the effect of premium increases. Using 2003 Medical Expenditure Panel Survey (MEPS) merged with CHIP premiums, we compare health insurance outcomes for CHIP eligible children as of January 2003 in states with a two-tier premium structure using a cross-sectional regression discontinuity methodology. We use difference-in-differences analysis to compare longitudinal insurance outcomes by December 2003. Higher CHIP premiums are associated with higher likelihood of private insurance. Disenrollment from CHIP in response to premium increases over time does not increase the uninsurance rate. When faced with higher CHIP premiums, private health insurance may be a preferable alternative for CHIP eligible families with higher incomes. Therefore, competition in the insurance exchanges being formed under the Affordable Care Act could enhance choice.

  15. Advanced flip chip packaging

    CERN Document Server

    Lai, Yi-Shao; Wong, CP

    2013-01-01

    Advanced Flip Chip Packaging presents past, present and future advances and trends in areas such as substrate technology, material development, and assembly processes. Flip chip packaging is now in widespread use in computing, communications, consumer and automotive electronics, and the demand for flip chip technology is continuing to grow in order to meet the need for products that offer better performance, are smaller, and are environmentally sustainable. This book also: Offers broad-ranging chapters with a focus on IC-package-system integration Provides viewpoints from leading industry executives and experts Details state-of-the-art achievements in process technologies and scientific research Presents a clear development history and touches on trends in the industry while also discussing up-to-date technology information Advanced Flip Chip Packaging is an ideal book for engineers, researchers, and graduate students interested in the field of flip chip packaging.

  16. UW VLSI chip tester

    Science.gov (United States)

    McKenzie, Neil

    1989-12-01

    We present a design for a low-cost, functional VLSI chip tester. It is based on the Apple MacIntosh II personal computer. It tests chips that have up to 128 pins. All pin drivers of the tester are bidirectional; each pin is programmed independently as an input or an output. The tester can test both static and dynamic chips. Rudimentary speed testing is provided. Chips are tested by executing C programs written by the user. A software library is provided for program development. Tests run under both the Mac Operating System and A/UX. The design is implemented using Xilinx Logic Cell Arrays. Price/performance tradeoffs are discussed.

  17. Development of a bio-chip dedicated to planetary exploration. First step: resistance studies to space conditions

    International Nuclear Information System (INIS)

    Le Postollec, A.; Dobrijevic, M.; Incerti, S.; Moretto, Ph.; Seznec, H.; Desorgher, L.; Santin, G.; Nieminen, P.; Dartnell, L.; Vandenabeele-Trambouze, O.; Coussot, G.

    2008-02-01

    For upcoming exploration missions, space agencies advocate the development of a new promising technique to search for traces of extent or extinct life: the bio-chip use. A bio-chip is a miniaturized device composed of biological sensitive systems fixed on a solid substrate. As space is a hazardous environment, a main concern relies on the resistance of a bio-chip to a panel of harsh constraints among which the resistance to radiations. Within the framework of the BiOMAS (Bio-chip for Organic Matter Analysis in Space) project, our team is currently developing a bio-chip especially designed for planetary exploration. We present here the methodology adopted and the beginning experiments to select the best constituents, to determine resistance levels and to define well-adapted protection for the bio-chip

  18. Cache-aware network-on-chip for chip multiprocessors

    Science.gov (United States)

    Tatas, Konstantinos; Kyriacou, Costas; Dekoulis, George; Demetriou, Demetris; Avraam, Costas; Christou, Anastasia

    2009-05-01

    This paper presents the hardware prototype of a Network-on-Chip (NoC) for a chip multiprocessor that provides support for cache coherence, cache prefetching and cache-aware thread scheduling. A NoC with support to these cache related mechanisms can assist in improving systems performance by reducing the cache miss ratio. The presented multi-core system employs the Data-Driven Multithreading (DDM) model of execution. In DDM thread scheduling is done according to data availability, thus the system is aware of the threads to be executed in the near future. This characteristic of the DDM model allows for cache aware thread scheduling and cache prefetching. The NoC prototype is a crossbar switch with output buffering that can support a cache-aware 4-node chip multiprocessor. The prototype is built on the Xilinx ML506 board equipped with a Xilinx Virtex-5 FPGA.

  19. Biomass energy from wood chips: Diesel fuel dependence?

    International Nuclear Information System (INIS)

    Timmons, Dave; Mejia, Cesar Viteri

    2010-01-01

    Most renewable energy sources depend to some extent on use of other, non-renewable sources. In this study we explore use of diesel fuel in producing and transporting woody biomass in the state of New Hampshire, USA. We use two methods to estimate the diesel fuel used in woody biomass production: 1) a calculation based on case studies of diesel consumption in different parts of the wood chip supply chain, and 2) to support extrapolating those results to a regional system, an econometric study of the variation of wood-chip prices with respect to diesel fuel prices. The econometric study relies on an assumption of fixed demand, then assesses variables impacting supply, with a focus on how the price of diesel fuel affects price of biomass supplied. The two methods yield similar results. The econometric study, representing overall regional practices, suggests that a $1.00 per liter increase in diesel fuel price is associated with a $5.59 per Mg increase in the price of wood chips. On an energy basis, the diesel fuel used directly in wood chip production and transportation appears to account for less than 2% of the potential energy in the wood chips. Thus, the dependence of woody biomass energy production on diesel fuel does not appear to be extreme. (author)

  20. Experiment list: SRX122496 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available || chip antibody=Rel || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip ant...ibody catalog number 1=sc-71 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc

  1. Smart vision chips: An overview

    Science.gov (United States)

    Koch, Christof

    1994-01-01

    This viewgraph presentation presents four working analog VLSI vision chips: (1) time-derivative retina, (2) zero-crossing chip, (3) resistive fuse, and (4) figure-ground chip; work in progress on computing motion and neuromorphic systems; and conceptual and practical lessons learned.

  2. Experiment list: SRX122465 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 6 || chip antibody=Relb || treatment=LPS || time=120 min || chip antibody manufacturer 1=Bethyl || chip anti...body catalog number 1=A302-183A || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2

  3. Experiment list: SRX122555 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available chip antibody=Stat1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip anti...body catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-7

  4. Microfluidic organ-on-chip technology for blood-brain barrier research.

    Science.gov (United States)

    van der Helm, Marinke W; van der Meer, Andries D; Eijkel, Jan C T; van den Berg, Albert; Segerink, Loes I

    2016-01-01

    Organs-on-chips are a new class of microengineered laboratory models that combine several of the advantages of current in vivo and in vitro models. In this review, we summarize the advances that have been made in the development of organ-on-chip models of the blood-brain barrier (BBBs-on-chips) and the challenges that are still ahead. The BBB is formed by specialized endothelial cells and separates blood from brain tissue. It protects the brain from harmful compounds from the blood and provides homeostasis for optimal neuronal function [corrected]. Studying BBB function and dysfunction is important for drug development and biomedical research. Microfluidic BBBs-on-chips enable real-time study of (human) cells in an engineered physiological microenvironment, for example incorporating small geometries and fluid flow as well as sensors. Examples of BBBs-on-chips in literature already show the potential of more realistic microenvironments and the study of organ-level functions. A key challenge in the field of BBB-on-chip development is the current lack of standardized quantification of parameters such as barrier permeability and shear stress. This limits the potential for direct comparison of the performance of different BBB-on-chip models to each other and existing models. We give recommendations for further standardization in model characterization and conclude that the rapidly emerging field of BBB-on-chip models holds great promise for further studies in BBB biology and drug development.

  5. On-chip digital power supply control for system-on-chip applications

    NARCIS (Netherlands)

    Meijer, M.; Pineda de Gyvez, J.; Otten, R.H.J.M.

    2005-01-01

    The authors presented an on-chip, fully-digital, power-supply control system. The scheme consists of two independent control loops that regulate power supply variations due to semiconductor process spread, temperature, and chip's workload. Smart power-switches working as linear voltage regulators

  6. Large-scale analysis of antisense transcription in wheat using the Affymetrix GeneChip Wheat Genome Array

    Directory of Open Access Journals (Sweden)

    Settles Matthew L

    2009-05-01

    Full Text Available Abstract Background Natural antisense transcripts (NATs are transcripts of the opposite DNA strand to the sense-strand either at the same locus (cis-encoded or a different locus (trans-encoded. They can affect gene expression at multiple stages including transcription, RNA processing and transport, and translation. NATs give rise to sense-antisense transcript pairs and the number of these identified has escalated greatly with the availability of DNA sequencing resources and public databases. Traditionally, NATs were identified by the alignment of full-length cDNAs or expressed sequence tags to genome sequences, but an alternative method for large-scale detection of sense-antisense transcript pairs involves the use of microarrays. In this study we developed a novel protocol to assay sense- and antisense-strand transcription on the 55 K Affymetrix GeneChip Wheat Genome Array, which is a 3' in vitro transcription (3'IVT expression array. We selected five different tissue types for assay to enable maximum discovery, and used the 'Chinese Spring' wheat genotype because most of the wheat GeneChip probe sequences were based on its genomic sequence. This study is the first report of using a 3'IVT expression array to discover the expression of natural sense-antisense transcript pairs, and may be considered as proof-of-concept. Results By using alternative target preparation schemes, both the sense- and antisense-strand derived transcripts were labeled and hybridized to the Wheat GeneChip. Quality assurance verified that successful hybridization did occur in the antisense-strand assay. A stringent threshold for positive hybridization was applied, which resulted in the identification of 110 sense-antisense transcript pairs, as well as 80 potentially antisense-specific transcripts. Strand-specific RT-PCR validated the microarray observations, and showed that antisense transcription is likely to be tissue specific. For the annotated sense

  7. ReseqChip: Automated integration of multiple local context probe data from the MitoChip array in mitochondrial DNA sequence assembly

    Directory of Open Access Journals (Sweden)

    Spang Rainer

    2009-12-01

    Full Text Available Abstract Background The Affymetrix MitoChip v2.0 is an oligonucleotide tiling array for the resequencing of the human mitochondrial (mt genome. For each of 16,569 nucleotide positions of the mt genome it holds two sets of four 25-mer probes each that match the heavy and the light strand of a reference mt genome and vary only at their central position to interrogate all four possible alleles. In addition, the MitoChip v2.0 carries alternative local context probes to account for known mtDNA variants. These probes have been neglected in most studies due to the lack of software for their automated analysis. Results We provide ReseqChip, a free software that automates the process of resequencing mtDNA using multiple local context probes on the MitoChip v2.0. ReseqChip significantly improves base call rate and sequence accuracy. ReseqChip is available at http://code.open-bio.org/svnweb/index.cgi/bioperl/browse/bioperl-live/trunk/Bio/Microarray/Tools/. Conclusions ReseqChip allows for the automated consolidation of base calls from alternative local mt genome context probes. It thereby improves the accuracy of resequencing, while reducing the number of non-called bases.

  8. Wood chips procurement and research project at the Mikkeli region

    International Nuclear Information System (INIS)

    Saksa, T.; Auvinen, P.

    1996-01-01

    In 1993-94, a large-scale energywood production chain started as a co-operation project by the Mikkeli city forest office and local forestry societies. In 1995 over 115 000 m 3 (about 85 000 MWh of energy) of wood chips were delivered to Pursiala heat and power plant in Mikkeli. About 75 % of these chips was forest processed chips. About 70 % of the forest processed chips was whole tree chips from improvement cuttings of young forest stands and the rest was logging waste chips from regeneration cutting areas. The average total delivery costs of forest processed chips after reduction of energywood and other subsidies were approximately 45 FIM/m 3 (60 FIM/MWh) for the whole tree chips and 38 FIM/m 3 (50 FIM/MWh) for logging waste chips. The delivery costs of forest processed chips could meet the target of Bioenergy Research Programme (45 FIM/MWh) only in the most favourable cases. In an average the delivery costs were about 9 FIM/MWh more than the price obtained when sold to the heat and power plant. However the wood chip production created 27 new jobs and the increase of income to the local economy was about 2.2 milj. FIM /year. The local communities got new tax revenue about 3 FIM/MWh. The gain for the forestry was approximated to be 5 - 6 FIM/MWh. The resources of forest processed chips were studied on the basis of stand measurements. According to the study the most remarkable energywood resources were in young thinning stands on Oxalis-Myrtillus and Myrtillus forest site types. On Oxalis-Myrtillus type almost every and on Myrtillus type every second stand included energywood more than 40 m 3 /ha

  9. Microfluidic Organ-on-a-Chip Models of Human IntestineSummary

    Directory of Open Access Journals (Sweden)

    Amir Bein

    Full Text Available Microfluidic organ-on-a-chip models of human intestine have been developed and used to study intestinal physiology and pathophysiology. In this article, we review this field and describe how microfluidic Intestine Chips offer new capabilities not possible with conventional culture systems or organoid cultures, including the ability to analyze contributions of individual cellular, chemical, and physical control parameters one-at-a-time; to coculture human intestinal cells with commensal microbiome for extended times; and to create human-relevant disease models. We also discuss potential future applications of human Intestine Chips, including how they might be used for drug development and personalized medicine. Keywords: Organs-on-Chips, Gut-on-a-Chip, Intestine-on-a-Chip, Microfluidic

  10. Transcript profiling of common bean (Phaseolus vulgaris L. using the GeneChip® Soybean Genome Array: optimizing analysis by masking biased probes

    Directory of Open Access Journals (Sweden)

    Gronwald John W

    2010-05-01

    Full Text Available Abstract Background Common bean (Phaseolus vulgaris L. and soybean (Glycine max both belong to the Phaseoleae tribe and share significant coding sequence homology. This suggests that the GeneChip® Soybean Genome Array (soybean GeneChip may be used for gene expression studies using common bean. Results To evaluate the utility of the soybean GeneChip for transcript profiling of common bean, we hybridized cRNAs purified from nodule, leaf, and root of common bean and soybean in triplicate to the soybean GeneChip. Initial data analysis showed a decreased sensitivity and accuracy of measuring differential gene expression in common bean cross-species hybridization (CSH GeneChip data compared to that of soybean. We employed a method that masked putative probes targeting inter-species variable (ISV regions between common bean and soybean. A masking signal intensity threshold was selected that optimized both sensitivity and accuracy of measuring differential gene expression. After masking for ISV regions, the number of differentially-expressed genes identified in common bean was increased by 2.8-fold reflecting increased sensitivity. Quantitative RT-PCR (qRT-PCR analysis of 20 randomly selected genes and purine-ureide pathway genes demonstrated an increased accuracy of measuring differential gene expression after masking for ISV regions. We also evaluated masked probe frequency per probe set to gain insight into the sequence divergence pattern between common bean and soybean. The sequence divergence pattern analysis suggested that the genes for basic cellular functions and metabolism were highly conserved between soybean and common bean. Additionally, our results show that some classes of genes, particularly those associated with environmental adaptation, are highly divergent. Conclusions The soybean GeneChip is a suitable cross-species platform for transcript profiling in common bean when used in combination with the masking protocol described. In

  11. Single chip camera active pixel sensor

    Science.gov (United States)

    Shaw, Timothy (Inventor); Pain, Bedabrata (Inventor); Olson, Brita (Inventor); Nixon, Robert H. (Inventor); Fossum, Eric R. (Inventor); Panicacci, Roger A. (Inventor); Mansoorian, Barmak (Inventor)

    2003-01-01

    A totally digital single chip camera includes communications to operate most of its structure in serial communication mode. The digital single chip camera include a D/A converter for converting an input digital word into an analog reference signal. The chip includes all of the necessary circuitry for operating the chip using a single pin.

  12. Spectroscopy study of imaging devices based on silicon Pixel Array Detector coupled to VATAGP7 read-out chips

    International Nuclear Information System (INIS)

    Linhart, V; Lacasta, C; Llosa, G; Stankova, V; Burdette, D; Chessi, E; Cochran, E; Honscheid, K; Kagan, H; Weilhammer, P; Cindro, V; Grosicar, B; Mikuz, M; Studen, A; Zontar, D; Clinthorne, N H

    2011-01-01

    Spectroscopic and timing response studies have been conducted on a detector module consisting of a silicon Pixel Array Detector bonded on two VATAGP7 read-out chips manufactured by Gamma-Medica Ideas using laboratory gamma sources and the internal calibration facilities (the calibration system of the read-out chips). The performed tests have proven that the chips have (i) non-linear calibration curves which can be approximated by power functions, (ii) capability to measure the energy of photons with energy resolution better than 2 keV (exact range and resolution depend on experimental setup), (iii) the internal calibration facility which provides 6 out of 16 available internal calibration charges within our region of interest (spanning the Compton edge of 511 keV photons). The peaks induced by the internal calibration facility are suitable for a fit of the calibration curves. However, they are not suitable for measurements of equivalent noise charge because their full width at half maximum varies with their amplitude. These facts indicate that the VATAGP7 chips are useful and precise tools for a wide variety of spectroscopic devices. We have also explored time walk of the module and peaking time of the spectroscopy signals provided by the chips. We have observed that (iv) the time walk is caused partly by the peaking time of the signals provided by the fast shaper of the chips and partly by the timing uncertainty related to the varying position of the photon interaction, (v) the peaking time of the spectroscopy signals provided by the chips increases with increasing pulse height.

  13. Studies for an upgrade of ALICE Inner Tracking System: Pixel chip characterization

    Directory of Open Access Journals (Sweden)

    Park Jonghan

    2017-01-01

    Full Text Available Inner Tracking System (ITS of ALICE is used for vertex determination and tracking. Future heavy-ion program at the LHC aims to run with high luminosity. To address this challenge, upgrade program of ITS is underway, which aims at better position resolution (factor of 3, high detection efficiency (>99%, high-rate readout capabilities (100 kHz for Pb-Pb and moderate radiation hardness (> 700 krad. The new ITS will be composed with 7 layers of silicon pixel chip based on Monolithic Active Pixel Sensor (MAPS technology. The characterization test of various version of prototype chips at different phases of development has been performed. This contribution will provide the main characterization results obtained from the measurements performed at laboratories and using test beam for finalizing the pixel chip specification.

  14. Interactive verification of Markov chains: Two distributed protocol case studies

    Directory of Open Access Journals (Sweden)

    Johannes Hölzl

    2012-12-01

    Full Text Available Probabilistic model checkers like PRISM only check probabilistic systems of a fixed size. To guarantee the desired properties for an arbitrary size, mathematical analysis is necessary. We show for two case studies how this can be done in the interactive proof assistant Isabelle/HOL. The first case study is a detailed description of how we verified properties of the ZeroConf protocol, a decentral address allocation protocol. The second case study shows the more involved verification of anonymity properties of the Crowds protocol, an anonymizing protocol.

  15. Ultra-thin chip technology and applications

    CERN Document Server

    2010-01-01

    Ultra-thin chips are the "smart skin" of a conventional silicon chip. This book shows how very thin and flexible chips can be fabricated and used in many new applications in microelectronics, microsystems, biomedical and other fields. It provides a comprehensive reference to the fabrication technology, post processing, characterization and the applications of ultra-thin chips.

  16. Photonic network-on-chip design

    CERN Document Server

    Bergman, Keren; Biberman, Aleksandr; Chan, Johnnie; Hendry, Gilbert

    2013-01-01

    This book provides a comprehensive synthesis of the theory and practice of photonic devices for networks-on-chip. It outlines the issues in designing photonic network-on-chip architectures for future many-core high performance chip multiprocessors. The discussion is built from the bottom up: starting with the design and implementation of key photonic devices and building blocks, reviewing networking and network-on-chip theory and existing research, and finishing with describing various architectures, their characteristics, and the impact they will have on a computing system. After acquainting

  17. Solid state silicon based condenser microphone for hearing aid, has transducer chip and IC chip between intermediate chip and openings on both sides of intermediate chip, to allow sound towards diaphragm

    DEFF Research Database (Denmark)

    2000-01-01

    towards diaphragm. Surface of the chip (2) has electrical conductors (14) to connect chip with IC chip (3). USE - For use in miniature electroacoustic devices such as hearing aid. ADVANTAGE - Since sound inlet is covered by filter, dust, moisture and other impurities do not obstruct interior and sound...... inlet of microphone. External electrical connection can be made economically reliable and the thermal stress is avoided with the small size solid state silicon based condenser microphone....

  18. Experiment list: SRX214086 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available entiated || cell line=KH2 || chip antibody 1=none || chip antibody manufacturer 1=none || chip antibody 2=none || chip antibody manuf...acturer 2=none http://dbarchive.biosciencedbc.jp/kyushu-

  19. Optical lattice on an atom chip

    DEFF Research Database (Denmark)

    Gallego, D.; Hofferberth, S.; Schumm, Thorsten

    2009-01-01

    Optical dipole traps and atom chips are two very powerful tools for the quantum manipulation of neutral atoms. We demonstrate that both methods can be combined by creating an optical lattice potential on an atom chip. A red-detuned laser beam is retroreflected using the atom chip surface as a high......-quality mirror, generating a vertical array of purely optical oblate traps. We transfer thermal atoms from the chip into the lattice and observe cooling into the two-dimensional regime. Using a chip-generated Bose-Einstein condensate, we demonstrate coherent Bloch oscillations in the lattice....

  20. Perspective: Fabrication of integrated organ-on-a-chip via bioprinting.

    Science.gov (United States)

    Yang, Qingzhen; Lian, Qin; Xu, Feng

    2017-05-01

    Organ-on-a-chip has emerged as a powerful platform with widespread applications in biomedical engineering, such as pathology studies and drug screening. However, the fabrication of organ-on-a-chip is still a challenging task due to its complexity. For an integrated organ-on-a-chip, it may contain four key elements, i.e., a microfluidic chip, live cells/microtissues that are cultured in this chip, components for stimulus loading to mature the microtissues, and sensors for results readout. Recently, bioprinting has been used for fabricating organ-on-a-chip as it enables the printing of multiple materials, including biocompatible materials and even live cells in a programmable manner with a high spatial resolution. Besides, all four elements for organ-on-a-chip could be printed in a single continuous procedure on one printer; in other words, the fabrication process is assembly free. In this paper, we discuss the recent advances of organ-on-a-chip fabrication by bioprinting. Light is shed on the printing strategies, materials, and biocompatibility. In addition, some specific bioprinted organs-on-chips are analyzed in detail. Because the bioprinted organ-on-a-chip is still in its early stage, significant efforts are still needed. Thus, the challenges presented together with possible solutions and future trends are also discussed.

  1. Experiment list: SRX214071 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Undifferentiated || treatment=Overexpress Sox2-V5 tagged || cell line=KH2 || chip antibody 1=none || chip antibody manufacture...r 1=none || chip antibody 2=V5 || chip antibody manufacturer 2=

  2. Experiment list: SRX214075 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available age=Undifferentiated || treatment=Overexpress Sox17EK-V5 tagged || cell line=KH2 || chip antibody 1=none || chip antibody manufacture...r 1=none || chip antibody 2=V5 || chip antibody manufacture

  3. Experiment list: SRX214074 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ge=Undifferentiated || treatment=Overexpress Sox17EK-V5 tagged || cell line=KH2 || chip antibody 1=none || chip antibody manufacture...r 1=none || chip antibody 2=V5 || chip antibody manufacture

  4. Experiment list: SRX214072 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available e=Undifferentiated || treatment=Overexpress Sox2KE-V5 tagged || cell line=KH2 || chip antibody 1=none || chip antibody manufacture...r 1=none || chip antibody 2=V5 || chip antibody manufacture

  5. Experiment list: SRX214067 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available fferentiated || cell line=F9 || chip antibody 1=Pou5f1/Oct4 || chip antibody manufacture...r 1=Santa Cruz || chip antibody 2=none || chip antibody manufacturer 2=none http://dbarchive.bioscien

  6. Experiment list: SRX122523 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Irf2 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab65048 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-498 http://

  7. Experiment list: SRX122414 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Junb || treatment=LPS || time=30 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http://d

  8. Experiment list: SRX214077 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available erentiated || treatment=Overexpress Sox17_V5 tagged || cell line=KH2 || chip antibody 1=Sox17 || chip antibody manufacture...r 1=R&D || chip antibody 2=V5 || chip antibody manufacturer 2=Invit

  9. Experiment list: SRX122485 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Atf3 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antibody ...catalog number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100

  10. Experiment list: SRX122521 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Irf2 || treatment=LPS || time=30 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab65048 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-498 http://

  11. Experiment list: SRX122417 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Junb || treatment=LPS || time=60 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http://d

  12. Experiment list: SRX122520 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Irf2 || treatment=LPS || time=30 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab65048 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-498 http://

  13. Experiment list: SRX122413 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Junb || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody catalo...g number 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http:/

  14. Experiment list: SRX122412 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Junb || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody catalo...g number 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http:/

  15. Experiment list: SRX122406 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Irf1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalog... number 1=ab52520 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-640 http:/

  16. Experiment list: SRX122415 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Junb || treatment=LPS || time=30 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http://d

  17. Experiment list: SRX122416 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Junb || treatment=LPS || time=60 min || chip antibody manufacturer 1=Abcam || chip antibody catalog ...number 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http://d

  18. Experiment list: SRX122565 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat2 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalog... number 1=ab53149 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-839 http:/

  19. Experiment list: SRX122510 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Egr1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalog... number 1=ab54966-100 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-110 ht

  20. Experiment list: SRX122519 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Irf2 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody catalo...g number 1=ab65048 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-498 http:

  1. Experiment list: SRX122472 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Runx1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalo...g number 1=ab61753 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-8564 http

  2. Experiment list: SRX122473 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Runx1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody ca...talog number 1=ab61753 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-8564

  3. Experiment list: SRX122497 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Rel || treatment=LPS || time=30 min || chip antibody manufacturer 1=Santa Cruz || chip antibody cat...alog number 1=sc-71 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-70 http:

  4. Experiment list: SRX122410 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Junb || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalog n...umber 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http://db

  5. Experiment list: SRX186172 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 1=YY1 || chip antibody manufacturer 1=Abcam || chip antibody 2=YY1 || chip antibody manufacturer 2=Santa Cru...ip-Seq; Mus musculus; ChIP-Seq source_name=Rag1 -/- pro-B cells || chip antibody

  6. Experiment list: SRX122493 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Atf4 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody catal...og number 1=ab28830-100 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-200

  7. Experiment list: SRX122571 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat2 || treatment=LPS || time=30 min || chip antibody manufacturer 1=Abcam || chip antibody catal...og number 1=ab53149 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-839 http

  8. Experiment list: SRX122411 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Junb || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalog n...umber 1=ab28838 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-46 http://db

  9. Experiment list: SRX122498 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Rel || treatment=LPS || time=60 min || chip antibody manufacturer 1=Santa Cruz || chip antibody cat...alog number 1=sc-71 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-70 http:

  10. Experiment list: SRX122516 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Irf2 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody catalo...g number 1=ab65048 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-498 http:

  11. Experiment list: SRX122495 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Rel || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody catal...og number 1=sc-71 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-70 http://

  12. Experiment list: SRX122563 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Santa Cruz || chip antibody ...catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A h

  13. Experiment list: SRX122564 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Santa Cruz || chip antibody ...catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A h

  14. Experiment list: SRX122488 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Atf3 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antibody c...atalog number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100 h

  15. Experiment list: SRX122491 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Atf3 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Santa Cruz || chip antibody cat...alog number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100 htt

  16. Experiment list: SRX122548 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody... catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A

  17. Experiment list: SRX122468 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Rela || treatment=LPS || time=0 min || chip antibody manufacturer 1=Bethyl || chip antibody catalo...g number 1=A301-824A || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-372 htt

  18. Experiment list: SRX122561 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=30 min || chip antibody manufacturer 1=Santa Cruz || chip antibody ...catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A h

  19. Experiment list: SRX122409 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Irf1 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Abcam || chip antibody cata...log number 1=ab52520 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-640 htt

  20. Experiment list: SRX122487 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Atf3 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antibody c...atalog number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100 h

  1. Experiment list: SRX122552 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Stat1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antibo...dy catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753

  2. Experiment list: SRX122408 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available p antibody=Irf1 || treatment=LPS || time=30 min || chip antibody manufacturer 1=Abcam || chip antibody catal...og number 1=ab52520 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-640 http

  3. Experiment list: SRX122513 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available p antibody=Egr1 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Abcam || chip antibody catal...og number 1=ab54966-100 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-110

  4. Experiment list: SRX122567 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available p antibody=Stat2 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody cat...alog number 1=ab53149 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-839 ht

  5. Experiment list: SRX122490 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Atf3 || treatment=LPS || time=30 min || chip antibody manufacturer 1=Santa Cruz || chip antibody cat...alog number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100 htt

  6. Experiment list: SRX122558 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available hip antibody=Stat1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antib...ody catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-75

  7. Experiment list: SRX122494 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available hip antibody=Atf4 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody ca...talog number 1=ab28830-100 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-2

  8. Experiment list: SRX122557 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available hip antibody=Stat1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antib...ody catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-75

  9. Experiment list: SRX122492 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Atf3 || treatment=LPS || time=60 min || chip antibody manufacturer 1=Santa Cruz || chip antibody cat...alog number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100 htt

  10. Experiment list: SRX122549 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody... catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A

  11. Experiment list: SRX122484 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ntibody=Atf3 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody cata...log number 1=sc-188 || chip antibody manufacturer 2=Abcam || chip antibody catalog number 2=ab70005-100 http

  12. Experiment list: SRX122514 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available tibody=Irf2 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Abcam || chip antibody catalog nu...mber 1=ab65048 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-498 http://db

  13. Experiment list: SRX122570 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available p antibody=Stat2 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody cat...alog number 1=ab53149 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-839 ht

  14. Experiment list: SRX122569 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Stat2 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody ca...talog number 1=ab53149 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-839 h

  15. Experiment list: SRX122511 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Egr1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Abcam || chip antibody cat...alog number 1=ab54966-100 || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-11

  16. Experiment list: SRX122471 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Rela || treatment=LPS || time=60 min || chip antibody manufacturer 1=Bethyl || chip antibody cat...alog number 1=A301-824A || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-372

  17. Experiment list: SRX122554 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ip antibody=Stat1 || treatment=LPS || time=120 min || chip antibody manufacturer 1=Santa Cruz || chip antibo...dy catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753

  18. Experiment list: SRX122551 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody ca...talog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A htt

  19. Experiment list: SRX122546 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available p antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody ...catalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A h

  20. Experiment list: SRX122547 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody c...atalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A ht

  1. Experiment list: SRX214084 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available turer 1=Santa Cruz || chip antibody 2=V5 || chip antibody manufacture...ge=Undifferentiated || treatment=Overexpress Sox17-V5 tagged || cell line=KH2 || chip antibody 1=Pou5f1/Oct4 || chip antibody manufac

  2. Experiment list: SRX122544 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody c...atalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A ht

  3. Experiment list: SRX214082 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available facturer 1=Santa Cruz || chip antibody 2=V5 || chip antibody manufacture...age=Undifferentiated || treatment=Overexpress Sox17EK-V5 tagged || cell line=KH2 || chip antibody 1=Pou5f1/Oct4 || chip antibody manu

  4. Experiment list: SRX122466 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available p antibody=Relb || treatment=LPS || time=30 min || chip antibody manufacturer 1=Bethyl || chip antibody cata...log number 1=A302-183A || chip antibody manufacturer 2=Santa Cruz || chip antibody catalog number 2=sc-226 h

  5. Experiment list: SRX122545 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available antibody=Stat1 || treatment=LPS || time=0 min || chip antibody manufacturer 1=Santa Cruz || chip antibody c...atalog number 1=sc-346 || chip antibody manufacturer 2=Bethyl || chip antibody catalog number 2=A302-753A ht

  6. Experiment list: SRX214080 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available cturer 1=Santa Cruz || chip antibody 2=V5 || chip antibody manufacture...ge=Undifferentiated || treatment=Overexpress Sox2KE-V5 tagged || cell line=KH2 || chip antibody 1=Pou5f1/Oct4 || chip antibody manufa

  7. Experiment list: SRX214081 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available cturer 1=Santa Cruz || chip antibody 2=V5 || chip antibody manufacture...ge=Undifferentiated || treatment=Overexpress Sox2KE-V5 tagged || cell line=KH2 || chip antibody 1=Pou5f1/Oct4 || chip antibody manufa

  8. Reagent-loaded plastic microfluidic chips for detecting homocysteine

    International Nuclear Information System (INIS)

    Suk, Ji Won; Jang, Jae-Young; Cho, Jun-Hyeong

    2008-01-01

    This report describes the preliminary study on plastic microfluidic chips with pre-loaded reagents for detecting homocysteine (Hcy). All reagents needed in an Hcy immunoassay were included in a microfluidic chip to remove tedious assay steps. A simple and cost-effective bonding method was developed to realize reagent-loaded microfluidic chips. This technique uses an intermediate layer between two plastic substrates by selectively patterning polydimethylsiloxane (PDMS) on the embossed surface of microchannels and fixing the substrates under pressure. Using this bonding method, the competitive immunoassay for SAH, a converted form of Hcy, was performed without any damage to reagents in chips, and the results showed that the fluorescent signal from antibody antigen binding decreased as the SAH concentration increased. Based on the SAH immunoassay, whole immunoassay steps for Hcy detection were carried out in plastic microfluidic chips with all necessary reagents. These experiments demonstrated the feasibility of the Hcy immunoassay in microfluidic devices

  9. Chipping operations and efficiency in different operational environments

    Energy Technology Data Exchange (ETDEWEB)

    Roeser, D.; Mola-Yudego, B.; Prinz, R.; Emer, B.; Sikanen, L., e-mail: dominik.roser@metla.fi

    2012-11-01

    This research analyses the productivity of energy wood chipping operations at several sites in Austria and Finland. The aim of the work is to examine the differences in productivity and the effects of the operational environment for the chipping of bioenergy at the roadside. Furthermore, the study quantifies the effects of different variables such as forest energy assortments, tree species, sieve size and machines on the overall productivity of chipping. The results revealed that there are significant differences in the chipping productivity in Austria and Finland which are largely based on the use of different sieve sizes. Furthermore, the different operational environments in both countries, as well as the characteristics of the raw material also seem to have an effect on productivity. In order to improve the chipping productivity, particularly in Central European conditions, all relevant stakeholders need to work jointly to find solutions that will allow a greater variation of chip size. Furthermore, in the future more consideration has to be given to the close interlinkage between the chipper, crane and grapple. As a result, investments costs can be optimized and operational costs and stress on the machines reduced. (orig.)

  10. Experiment list: SRX214068 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available inoic acid || cell line=F9 || chip antibody 1=Pou5f1/Oct4 || chip antibody manufacturer 1=Santa Cruz || chip... antibody 2=none || chip antibody manufacturer 2=none http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/eachDat

  11. Machinery for Forest Chip Production in Finland in 2007 and in the Future

    Energy Technology Data Exchange (ETDEWEB)

    Kaerhae, Kalle (Metsaeteho Oy, P.O. Box 101, FI-00171 Helsinki (Finland))

    2008-10-15

    Metsaeteho Oy's study consisted of a survey of the production machinery for forest chips used by energy plants in 2007. The major forest chip suppliers in Finland were involved in the study. In addition, the machinery and equipment stocked by the manufacturers and vendors of energy wood harvester heads, stump lifting devices, and chippers were also surveyed. The study provided also an estimate of future machinery requirements for forest chip production in Finland. The study estimated that a total of 1,100 machine and truck units were employed in the production of forest chips for energy plants in 2007. A total of 770 machine and truck units were contracted for the major forest chip suppliers in 2007. Increasing forest chip consumption will considerable increase the demand for additional forest chip production resources in the future. If the consumption of forest chips by energy plants in 2015 reaches 15 TWh, i.e. about 7.5 mill. m3, then the forest machine and truck requirement will be over 1,700 units. The corresponding machinery requirement at an energy plant with a forest chip consumption of 25 TWh (approx. 12.5 mill. m3), will be close to 2,300 machine and truck units

  12. ALICE chip processor

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    This tiny chip provides data processing for the time projection chamber on ALICE. Known as the ALICE TPC Read Out (ALTRO), this device was designed to minimize the size and power consumption of the TPC front end electronics. This single chip contains 16 low-power analogue-to-digital converters with six million transistors of digital processing and 8 kbits of data storage.

  13. The economic efficiency of forest energy wood chip production in regional use – A case study

    Directory of Open Access Journals (Sweden)

    Dalibor Šafařík

    2013-01-01

    Full Text Available This regional project case study deals with the limiting factors of economic efficiency in the production of forest energy wood chips. The evaluation of production efficiency made use of data obtained from the Lesy města Brna, a.s. (Forest of the City of Brno, Corp., which were subjected to two static methods of investment evaluation: an analysis of the tipping point and determination of the limit of variable costs and a dynamic modified tipping point analysis using cash flow (i.e. cash break even analysis. The results have confirmed an established hypothesis, namely that the decisive factor in the profitability of the production of forest energy wood chips hinges on the costs incurred in the gathering of raw material and the distribution of the produced chips. The results include a further limiting factor: transportation costs to the final consumption location. The output of the study is a recommendation that the concentration of residual forest materials not exceed a distance of 250 m from the place of production to the point of disintegration and that the transport distance of energy chips not exceed 50 km from the place of disintegration to the final consumption point. These limiting values help quantify the full internal costs per cost unit, full internal cost profitability, total revenue profitability and annual profitability expressed in terms of fixed assets depreciation without factoring in financial aid.

  14. Quality assessment of buccal versus blood genomic DNA using the Affymetrix 500 K GeneChip

    Directory of Open Access Journals (Sweden)

    Martin Lisa J

    2007-11-01

    Full Text Available Abstract Background With the advent of genome-wide genotyping, the utility of stored buccal brushes for DNA extraction and genotyping has been questioned. We sought to describe the genomic DNA yield and concordance between stored buccal brushes and blood samples from the same individuals in the context of Affymetrix 500 K Human GeneChip genotyping. Results Buccal cytobrushes stored for ~7 years at -80°C prior to extraction yielded sufficient double stranded DNA (dsDNA to be successfully genotyped on the Affymetrix ~262 K NspI chip, with yields between 536 and 1047 ng dsDNA. Using the BRLMM algorithm, genotyping call rates for blood samples averaged 98.4%, and for buccal samples averaged 97.8%. Matched blood samples exhibited 99.2% concordance, while matched blood and buccal samples exhibited 98.8% concordance. Conclusion Buccal cytobrushes stored long-term result in sufficient dsDNA concentrations to achieve high genotyping call rates and concordance with stored blood samples in the context of Affymetrix 500 K SNP genotyping. Thus, given high-quality collection and storage protocols, it is possible to use stored buccal cytobrush samples for genome-wide association studies.

  15. Adjunctive Effects of A Piscean Collagen-Based Controlled-Release Chlorhexidine Chip in the Treatment of Chronic Periodontitis: A Clinical and Microbiological Study

    Science.gov (United States)

    John, Priya; Lazarus, Flemingson; Selvam, Arul; Prabhuji, Munivenkatappa Lakshmaiah Venkatesh

    2015-01-01

    Introduction PerioChip a bovine origin gelatine based CHX chip has shown beneficial effects in the management of Chronic Periodontitis. A new fish collagen based CHX chip similar to PerioChip is currently available; however this product has not been thoroughly researched. Aim The aim of the present study was to evaluate the effectiveness of a new Piscean collagen-based controlled-release chlorhexidine chip (CHX chip) as an adjunctive therapy to scaling and root planing (SRP). Settings and Design The study was conducted as a randomised, split-mouth, controlled clinical trial at Krishnadevaraya College of Dental Sciences, Bangalore, India. Materials and Methods In a split–mouth study involving 20 sites in 10 patients with chronic periodontitis, control sites received scaling and root planing and test sites received scaling and root planing (SRP) and the intrapocket CHX chip placement as an adjunct. Subgingival plaque samples were collected from both control and test sites at baseline, 11 days and 11 weeks and the anaerobic colony count were assessed. Clinical parameters that were recorded at baseline and 11 weeks were gingival index, Plaque index, Probing pocket depth (PPD), and Clinical attachment level (CAL). Plaque index was recorded additionally at 11 days. Results In the test group there was a statistically significant reduction in the total anaerobic colony count, gingival index and plaque scores from baseline as compared to control sites at all time intervals. An additional 0.8mm reduction in mean probing pocket depth was noted in the test group. Gain in Clinical attachment level was comparable in both groups. Conclusion The adjunctive use of the new collagen-based CHX chip yielded significant antimicrobial benefit accompanied by a reduction in probing depth and a clinical attachment level gain as compared to SRP alone. This suggests that it may be a useful treatment option of nonsurgical periodontal treatment of chronic periodontitis. PMID:26155567

  16. Compact Modbus TCP/IP protocol for data acquisition systems based on limited hardware resources

    Science.gov (United States)

    Bai, Q.; Jin, B.; Wang, D.; Wang, Y.; Liu, X.

    2018-04-01

    The Modbus TCP/IP has been a standard industry communication protocol and widely utilized for establishing sensor-cloud platforms on the Internet. However, numerous existing data acquisition systems built on traditional single-chip microcontrollers without sufficient resources cannot support it, because the complete Modbus TCP/IP protocol always works dependent on a full operating system which occupies abundant hardware resources. Hence, a compact Modbus TCP/IP protocol is proposed in this work to make it run efficiently and stably even on a resource-limited hardware platform. Firstly, the Modbus TCP/IP protocol stack is analyzed and the refined protocol suite is rebuilt by streamlining the typical TCP/IP suite. Then, specific implementation of every hierarchical layer is respectively presented in detail according to the protocol structure. Besides, the compact protocol is implemented in a traditional microprocessor to validate the feasibility of the scheme. Finally, the performance of the proposed scenario is assessed. The experimental results demonstrate that message packets match the frame format of Modbus TCP/IP protocol and the average bandwidth reaches to 1.15 Mbps. The compact protocol operates stably even based on a traditional microcontroller with only 4-kB RAM and 12-MHz system clock, and no communication congestion or frequent packet loss occurs.

  17. Cytotoxicity of cadmium-containing quantum dots based on a study using a microfluidic chip

    International Nuclear Information System (INIS)

    Zheng Xiannuo; Weng Lixing; Tian Jing; Wang Lianhui; Wu Lei; Jin Qinghui; Zhao Jianlong

    2012-01-01

    There is a lack of reliable nanotoxicity assays available for monitoring and quantifying multiple cellular events in cultured cells. In this study, we used a microfluidic chip to systematically investigate the cytotoxicity of three kinds of well-characterized cadmium-containing quantum dots (QDs) with the same core but different shell structures, including CdTe core QDs, CdTe/CdS core–shell QDs, and CdTe/CdS/ZnS core–shell–shell QDs, in HEK293 cells. Using the microfluidic chip combined with fluorescence microscopy, multiple QD-induced cellular events including cell morphology, viability, proliferation, and QD uptake were simultaneously analysed. The three kinds of QDs showed significantly different cytotoxicities. The CdTe QDs, which are highly toxic to HEK293 cells, resulted in remarkable cellular and nuclear morphological changes, a dose-dependent decrease in cell viability, and strong inhibition of cell proliferation; the CdTe/CdS QDs were moderately toxic but did not significantly affect the proliferation of HEK293 cells; while the CdTe/CdS/ZnS QDs had no detectable influence on cytotoxicity with respect to cell morphology, viability, and proliferation. Our data indicated that QD cytotoxicity was closely related to their surface structures and specific physicochemical properties. This study also demonstrated that the microfluidic chip could serve as a powerful tool to systematically evaluate the cytotoxicity of nanoparticles in multiple cellular events. (paper)

  18. Cytotoxicity of cadmium-containing quantum dots based on a study using a microfluidic chip

    Science.gov (United States)

    Zheng, Xiannuo; Tian, Jing; Weng, Lixing; Wu, Lei; Jin, Qinghui; Zhao, Jianlong; Wang, Lianhui

    2012-02-01

    There is a lack of reliable nanotoxicity assays available for monitoring and quantifying multiple cellular events in cultured cells. In this study, we used a microfluidic chip to systematically investigate the cytotoxicity of three kinds of well-characterized cadmium-containing quantum dots (QDs) with the same core but different shell structures, including CdTe core QDs, CdTe/CdS core-shell QDs, and CdTe/CdS/ZnS core-shell-shell QDs, in HEK293 cells. Using the microfluidic chip combined with fluorescence microscopy, multiple QD-induced cellular events including cell morphology, viability, proliferation, and QD uptake were simultaneously analysed. The three kinds of QDs showed significantly different cytotoxicities. The CdTe QDs, which are highly toxic to HEK293 cells, resulted in remarkable cellular and nuclear morphological changes, a dose-dependent decrease in cell viability, and strong inhibition of cell proliferation; the CdTe/CdS QDs were moderately toxic but did not significantly affect the proliferation of HEK293 cells; while the CdTe/CdS/ZnS QDs had no detectable influence on cytotoxicity with respect to cell morphology, viability, and proliferation. Our data indicated that QD cytotoxicity was closely related to their surface structures and specific physicochemical properties. This study also demonstrated that the microfluidic chip could serve as a powerful tool to systematically evaluate the cytotoxicity of nanoparticles in multiple cellular events.

  19. Pelly Crossing wood chip boiler

    Energy Technology Data Exchange (ETDEWEB)

    1985-03-11

    The Pelly wood chip project has demonstrated that wood chips are a successful fuel for space and domestic water heating in a northern climate. Pelly Crossing was chosen as a demonstration site for the following reasons: its extreme temperatures, an abundant local supply of resource material, the high cost of fuel oil heating and a lack of local employment. The major obstacle to the smooth operation of the boiler system was the poor quality of the chip supply. The production of poor quality chips has been caused by inadequate operation and maintenance of the chipper. Dull knives and faulty anvil adjustments produced chips and splinters far in excess of the one centimetre size specified for the system's design. Unanticipated complications have caused costs of the system to be higher than expected by approximately $15,000. The actual cost of the project was approximately $165,000. The first year of the system's operation was expected to accrue $11,600 in heating cost savings. This estimate was impossible to confirm given the system's irregular operation and incremental costs. Consistent operation of the system for a period of at least one year plus the installation of monitoring devices will allow the cost effectiveness to be calculated. The wood chip system's impact on the environment was estimated to be minimal. Wood chip burning was considered cleaner and safer than cordwood burning. 9 refs., 6 figs., 6 tabs.

  20. An innovative container supply chain for forest chips

    Energy Technology Data Exchange (ETDEWEB)

    Karttunen, Kalle; Korpinen, Olli-Jussi; Laettilae, Lauri; Foehr, Jarno; Ranta, Tapio [Lappeenranta Univ. of Technology, Mikkeli (Finland)], e-mail: kalle.karttunen@lut.fi

    2012-11-01

    Most forest chips are transported by trucks with a solid frame. Forest-chip volumes will at least double before 2020, which means longer transport distances from the supply areas to the largest demand sites in Finland. The study concentrates on an innovative container solution based on a channel composite structure, creating a lighter, temperature-isolated, and more durable structure. In addition to the structural benefits, the container includes an innovative supply chain with a beneficial handling operation, interchangeability and maximising of the payload capacity, resulting in an energy- and cost-efficient solution. This innovative-container-based supply chain for forest chips has been studied via cost analysis, GIS analysis, and discrete-event simulation methods. The purpose of the study was to compare a truck of interchangeable containers with solid-frame trucks. The option of interchangeable containers allows combining truck logistics with other modes of transport, such as trains and waterways. The study showed the cost-efficiency potential of container truck logistics, stemming from the cost and payload savings and the supply-chain productivity advantages over solid-frame trucks. The innovative solution for interchangeable-container logistics is an option for large-scale supply of forest chips.

  1. Biostability of an implantable glucose sensor chip

    Science.gov (United States)

    Fröhlich, M.; Birkholz, M.; Ehwald, K. E.; Kulse, P.; Fursenko, O.; Katzer, J.

    2012-12-01

    Surface materials of an implantable microelectronic chip intended for medical applications were evaluated with respect to their long-term stability in bio-environments. The sensor chip shall apply in a glucose monitor by operating as a microviscosimeter according to the principle of affinity viscosimetry. A monolithic integration of a microelectromechanical system (MEMS) into the sensor chip was successfully performed in a combined 0.25 μm CMOS/BiCMOS technology. In order to study material durability and biostability of the surfaces, sensor chips were exposed to various in vitro and in vivo tests. Corrosional damage of SiON, SiO2 and TiN surfaces was investigated by optical microscopy, ellipsometry and AFM. The results served for optimizing the Back-end-of-Line (BEoL) stack, from which the MEMS was prepared. Corrosion of metal lines could significantly be reduced by improving the topmost passivation layer. The experiments revealed no visible damage of the actuator or other functionally important MEMS elements. Sensor chips were also exposed to human body fluid for three month by implantation into the abdomen of a volunteer. Only small effects were observed for layer thickness and Ra roughness after explantation. In particular, TiN as used for the actuator beam showed no degradation by biocorrosion. The highest degradation rate of about 50 nm per month was revealed for the SiON passivation layer. These results suggest that the sensor chip may safely operate in subcutaneous tissue for a period of several months.

  2. Biostability of an implantable glucose sensor chip

    International Nuclear Information System (INIS)

    Fröhlich, M; Ehwald, K E; Kulse, P; Fursenko, O; Katzer, J; Birkholz, M

    2012-01-01

    Surface materials of an implantable microelectronic chip intended for medical applications were evaluated with respect to their long-term stability in bio-environments. The sensor chip shall apply in a glucose monitor by operating as a microviscosimeter according to the principle of affinity viscosimetry. A monolithic integration of a microelectromechanical system (MEMS) into the sensor chip was successfully performed in a combined 0.25 μm CMOS/BiCMOS technology. In order to study material durability and biostability of the surfaces, sensor chips were exposed to various in vitro and in vivo tests. Corrosional damage of SiON, SiO 2 and TiN surfaces was investigated by optical microscopy, ellipsometry and AFM. The results served for optimizing the Back-end-of-Line (BEoL) stack, from which the MEMS was prepared. Corrosion of metal lines could significantly be reduced by improving the topmost passivation layer. The experiments revealed no visible damage of the actuator or other functionally important MEMS elements. Sensor chips were also exposed to human body fluid for three month by implantation into the abdomen of a volunteer. Only small effects were observed for layer thickness and R a roughness after explantation. In particular, TiN as used for the actuator beam showed no degradation by biocorrosion. The highest degradation rate of about 50 nm per month was revealed for the SiON passivation layer. These results suggest that the sensor chip may safely operate in subcutaneous tissue for a period of several months.

  3. Washing scaling of GeneChip microarray expression

    Directory of Open Access Journals (Sweden)

    Krohn Knut

    2010-05-01

    Full Text Available Abstract Background Post-hybridization washing is an essential part of microarray experiments. Both the quality of the experimental washing protocol and adequate consideration of washing in intensity calibration ultimately affect the quality of the expression estimates extracted from the microarray intensities. Results We conducted experiments on GeneChip microarrays with altered protocols for washing, scanning and staining to study the probe-level intensity changes as a function of the number of washing cycles. For calibration and analysis of the intensity data we make use of the 'hook' method which allows intensity contributions due to non-specific and specific hybridization of perfect match (PM and mismatch (MM probes to be disentangled in a sequence specific manner. On average, washing according to the standard protocol removes about 90% of the non-specific background and about 30-50% and less than 10% of the specific targets from the MM and PM, respectively. Analysis of the washing kinetics shows that the signal-to-noise ratio doubles roughly every ten stringent washing cycles. Washing can be characterized by time-dependent rate constants which reflect the heterogeneous character of target binding to microarray probes. We propose an empirical washing function which estimates the survival of probe bound targets. It depends on the intensity contribution due to specific and non-specific hybridization per probe which can be estimated for each probe using existing methods. The washing function allows probe intensities to be calibrated for the effect of washing. On a relative scale, proper calibration for washing markedly increases expression measures, especially in the limit of small and large values. Conclusions Washing is among the factors which potentially distort expression measures. The proposed first-order correction method allows direct implementation in existing calibration algorithms for microarray data. We provide an experimental

  4. The GenoChip: a new tool for genetic anthropology.

    Science.gov (United States)

    Elhaik, Eran; Greenspan, Elliott; Staats, Sean; Krahn, Thomas; Tyler-Smith, Chris; Xue, Yali; Tofanelli, Sergio; Francalacci, Paolo; Cucca, Francesco; Pagani, Luca; Jin, Li; Li, Hui; Schurr, Theodore G; Greenspan, Bennett; Spencer Wells, R

    2013-01-01

    The Genographic Project is an international effort aimed at charting human migratory history. The project is nonprofit and nonmedical, and, through its Legacy Fund, supports locally led efforts to preserve indigenous and traditional cultures. Although the first phase of the project was focused on uniparentally inherited markers on the Y-chromosome and mitochondrial DNA (mtDNA), the current phase focuses on markers from across the entire genome to obtain a more complete understanding of human genetic variation. Although many commercial arrays exist for genome-wide single-nucleotide polymorphism (SNP) genotyping, they were designed for medical genetic studies and contain medically related markers that are inappropriate for global population genetic studies. GenoChip, the Genographic Project's new genotyping array, was designed to resolve these issues and enable higher resolution research into outstanding questions in genetic anthropology. The GenoChip includes ancestry informative markers obtained for over 450 human populations, an ancient human (Saqqaq), and two archaic hominins (Neanderthal and Denisovan) and was designed to identify all known Y-chromosome and mtDNA haplogroups. The chip was carefully vetted to avoid inclusion of medically relevant markers. To demonstrate its capabilities, we compared the FST distributions of GenoChip SNPs to those of two commercial arrays. Although all arrays yielded similarly shaped (inverse J) FST distributions, the GenoChip autosomal and X-chromosomal distributions had the highest mean FST, attesting to its ability to discern subpopulations. The chip performances are illustrated in a principal component analysis for 14 worldwide populations. In summary, the GenoChip is a dedicated genotyping platform for genetic anthropology. With an unprecedented number of approximately 12,000 Y-chromosomal and approximately 3,300 mtDNA SNPs and over 130,000 autosomal and X-chromosomal SNPs without any known health, medical, or phenotypic

  5. The GenoChip: A New Tool for Genetic Anthropology

    Science.gov (United States)

    Elhaik, Eran; Greenspan, Elliott; Staats, Sean; Krahn, Thomas; Tyler-Smith, Chris; Xue, Yali; Tofanelli, Sergio; Francalacci, Paolo; Cucca, Francesco; Pagani, Luca; Jin, Li; Li, Hui; Schurr, Theodore G.; Greenspan, Bennett; Spencer Wells, R.

    2013-01-01

    The Genographic Project is an international effort aimed at charting human migratory history. The project is nonprofit and nonmedical, and, through its Legacy Fund, supports locally led efforts to preserve indigenous and traditional cultures. Although the first phase of the project was focused on uniparentally inherited markers on the Y-chromosome and mitochondrial DNA (mtDNA), the current phase focuses on markers from across the entire genome to obtain a more complete understanding of human genetic variation. Although many commercial arrays exist for genome-wide single-nucleotide polymorphism (SNP) genotyping, they were designed for medical genetic studies and contain medically related markers that are inappropriate for global population genetic studies. GenoChip, the Genographic Project’s new genotyping array, was designed to resolve these issues and enable higher resolution research into outstanding questions in genetic anthropology. The GenoChip includes ancestry informative markers obtained for over 450 human populations, an ancient human (Saqqaq), and two archaic hominins (Neanderthal and Denisovan) and was designed to identify all known Y-chromosome and mtDNA haplogroups. The chip was carefully vetted to avoid inclusion of medically relevant markers. To demonstrate its capabilities, we compared the FST distributions of GenoChip SNPs to those of two commercial arrays. Although all arrays yielded similarly shaped (inverse J) FST distributions, the GenoChip autosomal and X-chromosomal distributions had the highest mean FST, attesting to its ability to discern subpopulations. The chip performances are illustrated in a principal component analysis for 14 worldwide populations. In summary, the GenoChip is a dedicated genotyping platform for genetic anthropology. With an unprecedented number of approximately 12,000 Y-chromosomal and approximately 3,300 mtDNA SNPs and over 130,000 autosomal and X-chromosomal SNPs without any known health, medical, or phenotypic

  6. Study of a Microfluidic Chip Integrating Single Cell Trap and 3D Stable Rotation Manipulation

    Directory of Open Access Journals (Sweden)

    Liang Huang

    2016-08-01

    Full Text Available Single cell manipulation technology has been widely applied in biological fields, such as cell injection/enucleation, cell physiological measurement, and cell imaging. Recently, a biochip platform with a novel configuration of electrodes for cell 3D rotation has been successfully developed by generating rotating electric fields. However, the rotation platform still has two major shortcomings that need to be improved. The primary problem is that there is no on-chip module to facilitate the placement of a single cell into the rotation chamber, which causes very low efficiency in experiment to manually pipette single 10-micron-scale cells into rotation position. Secondly, the cell in the chamber may suffer from unstable rotation, which includes gravity-induced sinking down to the chamber bottom or electric-force-induced on-plane movement. To solve the two problems, in this paper we propose a new microfluidic chip with manipulation capabilities of single cell trap and single cell 3D stable rotation, both on one chip. The new microfluidic chip consists of two parts. The top capture part is based on the least flow resistance principle and is used to capture a single cell and to transport it to the rotation chamber. The bottom rotation part is based on dielectrophoresis (DEP and is used to 3D rotate the single cell in the rotation chamber with enhanced stability. The two parts are aligned and bonded together to form closed channels for microfluidic handling. Using COMSOL simulation and preliminary experiments, we have verified, in principle, the concept of on-chip single cell traps and 3D stable rotation, and identified key parameters for chip structures, microfluidic handling, and electrode configurations. The work has laid a solid foundation for on-going chip fabrication and experiment validation.

  7. A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection

    Directory of Open Access Journals (Sweden)

    Diwei He

    2015-07-01

    Full Text Available Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 µm CMOS process. The chip includes photodiode, transimpedance amplifier, analogue band-pass filters, analogue-to-digital converters, digital signal processor and LED timing control. The experimentally measured AC and DC characteristics of individual circuits including the DC output voltage of the transimpedance amplifier, transimpedance gain of the transimpedance amplifier, and the central frequency and bandwidth of the analogue band-pass filters, show a good match (within 1% with the circuit simulations. With modulated light source and integrated lock-in detection the sensor effectively suppresses the interference from ambient light and 1/f noise. In a breath hold and release experiment the single chip sensor demonstrates consistent and comparable performance to commercial pulse oximetry devices with a mean of 1.2% difference. The single-chip sensor enables a compact and robust design solution that offers a route towards wearable devices for health monitoring.

  8. A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection.

    Science.gov (United States)

    He, Diwei; Morgan, Stephen P; Trachanis, Dimitrios; van Hese, Jan; Drogoudis, Dimitris; Fummi, Franco; Stefanni, Francesco; Guarnieri, Valerio; Hayes-Gill, Barrie R

    2015-07-14

    Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 µm CMOS process. The chip includes photodiode, transimpedance amplifier, analogue band-pass filters, analogue-to-digital converters, digital signal processor and LED timing control. The experimentally measured AC and DC characteristics of individual circuits including the DC output voltage of the transimpedance amplifier, transimpedance gain of the transimpedance amplifier, and the central frequency and bandwidth of the analogue band-pass filters, show a good match (within 1%) with the circuit simulations. With modulated light source and integrated lock-in detection the sensor effectively suppresses the interference from ambient light and 1/f noise. In a breath hold and release experiment the single chip sensor demonstrates consistent and comparable performance to commercial pulse oximetry devices with a mean of 1.2% difference. The single-chip sensor enables a compact and robust design solution that offers a route towards wearable devices for health monitoring.

  9. Identifying Professional Competencies of the Flip-Chip Packaging Engineer in Taiwan

    Science.gov (United States)

    Guu, Y. H.; Lin, Kuen-Yi; Lee, Lung-Sheng

    2014-01-01

    This study employed a literature review, expert interviews, and a questionnaire survey to construct a set of two-tier competencies for a flip-chip packaging engineer. The fuzzy Delphi questionnaire was sent to 12 flip-chip engineering experts to identify professional competencies that a flip-chip packaging engineer must have. Four competencies,…

  10. Chip-Level Electromigration Reliability for Cu Interconnects

    International Nuclear Information System (INIS)

    Gall, M.; Oh, C.; Grinshpon, A.; Zolotov, V.; Panda, R.; Demircan, E.; Mueller, J.; Justison, P.; Ramakrishna, K.; Thrasher, S.; Hernandez, R.; Herrick, M.; Fox, R.; Boeck, B.; Kawasaki, H.; Haznedar, H.; Ku, P.

    2004-01-01

    Even after the successful introduction of Cu-based metallization, the electromigration (EM) failure risk has remained one of the most important reliability concerns for most advanced process technologies. Ever increasing operating current densities and the introduction of low-k materials in the backend process scheme are some of the issues that threaten reliable, long-term operation at elevated temperatures. The traditional method of verifying EM reliability only through current density limit checks is proving to be inadequate in general, or quite expensive at the best. A Statistical EM Budgeting (SEB) methodology has been proposed to assess more realistic chip-level EM reliability from the complex statistical distribution of currents in a chip. To be valuable, this approach requires accurate estimation of currents for all interconnect segments in a chip. However, no efficient technique to manage the complexity of such a task for very large chip designs is known. We present an efficient method to estimate currents exhaustively for all interconnects in a chip. The proposed method uses pre-characterization of cells and macros, and steps to identify and filter out symmetrically bi-directional interconnects. We illustrate the strength of the proposed approach using a high-performance microprocessor design for embedded applications as a case study

  11. Study protocol for the Cities Changing Diabetes programme

    DEFF Research Database (Denmark)

    Napier, A David; Nolan, John J; Bagger, Malene

    2017-01-01

    and management are improving, complications remain common, and diabetes is among the leading causes of vision loss, amputation, neuropathy and renal and cardiovascular disease worldwide. We present a research protocol for exploring the drivers of type 2 diabetes and its complications in urban settings through...... the Cities Changing Diabetes (CCD) partnership programme. METHODS AND ANALYSIS: A global study protocol is implemented in eight collaborating CCD partner cities. In each city, academic institutions, municipal representatives and local stakeholders collaborate to set research priorities and plan...... Assessment explores the urban context in vulnerability to type 2 diabetes and identifies social factors and cultural determinants relevant to health, well-being and diabetes. ETHICS AND DISSEMINATION: The protocol steers the collection of primary and secondary data across the study sites. Research ethics...

  12. Hardware-Enabled Security Through On-Chip Reconfigurable Fabric

    Science.gov (United States)

    2016-02-05

    level language (SystemC) instead of in RTL such as Verilog and VHDL . To evaluate our approach, we implemented a set of monitors including soft...techniques can be implemented after chip fabrication. The study showed that such programmable architectures can indeed support a broad range of run- time...accelerators where security techniques can be implemented after chip fabrication. The study showed that such programmable architectures can indeed support a

  13. CHIP: Commodity based Hazard Identification Protocol for emerging diseases in plants and animals

    NARCIS (Netherlands)

    Bremmer, J.; Swanenburg, M.; Galen, van M.A.; Hoek, Maarten; Rau, M.L.; Hennen, W.H.G.J.; Benninga, J.; Ge, L.; Breukers, M.L.H.

    2012-01-01

    This project comprised the development of a commodity-based hazard identification protocol for biological hazards in plants and animals as a decision support tree programmed in Excel. The content of the decision tree is based on the results of a systematic review of pest and pathogen

  14. A Study of Shared-Memory Mutual Exclusion Protocols Using CADP

    Science.gov (United States)

    Mateescu, Radu; Serwe, Wendelin

    Mutual exclusion protocols are an essential building block of concurrent systems: indeed, such a protocol is required whenever a shared resource has to be protected against concurrent non-atomic accesses. Hence, many variants of mutual exclusion protocols exist in the shared-memory setting, such as Peterson's or Dekker's well-known protocols. Although the functional correctness of these protocols has been studied extensively, relatively little attention has been paid to their non-functional aspects, such as their performance in the long run. In this paper, we report on experiments with the performance evaluation of mutual exclusion protocols using Interactive Markov Chains. Steady-state analysis provides an additional criterion for comparing protocols, which complements the verification of their functional properties. We also carefully re-examined the functional properties, whose accurate formulation as temporal logic formulas in the action-based setting turns out to be quite involved.

  15. Production of conjugated linoleic acid-rich potato chips.

    Science.gov (United States)

    Jain, Vishal P; Proctor, Andrew

    2007-01-01

    Conjugated linoleic acid (CLA) is found primarily in diary and beef products, but the health benefits of CLA can only be realized if they are consumed at much greater levels than a normal healthy dietary intake. We have recently shown that a CLA-rich soy oil can be produced by simple isomerization of linoleic acid in soy oil by photoirradiation. This oil may allow greatly increased dietary CLA without significantly elevating fat intake. The objective of this study was to prepare CLA-rich potato chips by frying in CLA-rich soy oil. Soy oil was photoisomerized in the presence of iodine catalyst with UV/visible light. The irradiated oil was clay processed to remove the residual iodine and this oil was then used to fry potato chips. Oil was extracted from fried chips and analyzed for its CLA content with gas chromatography. A 1-oz serving of CLA-rich potato chips contained approximately 2.4 g CLA as compared to 0.1 g CLA in 3-oz serving of steak fillet and 0.06 g CLA in 8-oz serving of whole milk. The peroxide value of the oil extracted from potato chips was found to be 1 meq/1000 g sample, which was within the acceptable commercial standards. This study may lead to the commercialization of CLA-rich food products.

  16. The CHIPS Randomized Controlled Trial (Control of Hypertension in Pregnancy Study): Is Severe Hypertension Just an Elevated Blood Pressure?

    Science.gov (United States)

    Magee, Laura A; von Dadelszen, Peter; Singer, Joel; Lee, Terry; Rey, Evelyne; Ross, Susan; Asztalos, Elizabeth; Murphy, Kellie E; Menzies, Jennifer; Sanchez, Johanna; Gafni, Amiram; Helewa, Michael; Hutton, Eileen; Koren, Gideon; Lee, Shoo K; Logan, Alexander G; Ganzevoort, Wessel; Welch, Ross; Thornton, Jim G; Moutquin, Jean-Marie

    2016-11-01

    To determine whether clinical outcomes differed by occurrence of severe hypertension in the international CHIPS trial (Control of Hypertension in Pregnancy Study), adjusting for the interventions of "less tight" (target diastolic blood pressure [dBP] 100 mm Hg) versus "tight" control (target dBP 85 mm Hg). In this post-hoc analysis of CHIPS data from 987 women with nonsevere nonproteinuric preexisting or gestational hypertension, mixed effects logistic regression was used to compare the following outcomes according to occurrence of severe hypertension, adjusting for allocated group and the influence of baseline factors: CHIPS primary (perinatal loss or high-level neonatal care for >48 hours) and secondary outcomes (serious maternal complications), birth weight hypertension that was associated with all outcomes examined except for maternal readmission (P=0.20): CHIPS primary outcome, birth weight hypertension and serious maternal complications was seen only in less tight control (P=0.02). Adjustment for preeclampsia (464, 47.3%) did not negate the relationship between severe hypertension and the CHIPS primary outcome (Phypertension is a risk marker for adverse maternal and perinatal outcomes, independent of BP control or preeclampsia co-occurrence. URL: http://pre-empt.cfri.ca/. Unique identifier: ISRCTN 71416914. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT01192412. © 2016 The Authors.

  17. A UHF RFID system with on-chip-antenna tag for short range communication

    International Nuclear Information System (INIS)

    Peng Qi; Zhang Chun; Zhao Xijin; Wang Zhihua

    2015-01-01

    A UHF RF identification system based on the 0.18 μm CMOS process has been developed for short range and harsh size requirement applications, which is composed of a fully integrated tag and a special reader. The whole tag chip with the antenna takes up an area of 0.36 mm 2 , which is smaller than other reported tags with an on-chip antenna (OCA) using the standard CMOS process. A self-defined protocol is proposed to reduce the power consumption, and minimize the size of the tag. The specialized SOC reader system consists of the RF transceiver, digital baseband, MCU and host interface. Its power consumption is about 500 mW. Measurement results show that the system's reading range is 2 mm with 20 dBm reader output power. With an inductive antenna printed on a paper substrate around the OCA tag, the reading range can be extended from several centimeters to meters, depending on the shape and size of the inductive antenna. (paper)

  18. Chip cleaning and regeneration for electrochemical sensor arrays

    Energy Technology Data Exchange (ETDEWEB)

    Bhalla, Vijayender [Biochemistry Department ' G.Moruzzi' , University of Bologna, Via Irnerio 48, 40126 Bologna (Italy); Carrara, Sandro, E-mail: sandro.carrara@epfl.c [Biochemistry Department ' G.Moruzzi' , University of Bologna, Via Irnerio 48, 40126 Bologna (Italy); Stagni, Claudio [Department DEIS, University of Bologna, viale Risorgimento 2, 40136 Bologna (Italy); Samori, Bruno [Biochemistry Department ' G.Moruzzi' , University of Bologna, Via Irnerio 48, 40126 Bologna (Italy)

    2010-04-02

    Sensing systems based on electrochemical detection have generated great interest because electronic readout may replace conventional optical readout in microarray. Moreover, they offer the possibility to avoid labelling for target molecules. A typical electrochemical array consists of many sensing sites. An ideal micro-fabricated sensor-chip should have the same measured values for all the equivalent sensing sites (or spots). To achieve high reliability in electrochemical measurements, high quality in functionalization of the electrodes surface is essential. Molecular probes are often immobilized by using alkanethiols onto gold electrodes. Applying effective cleaning methods on the chip is a fundamental requirement for the formation of densely-packed and stable self-assembly monolayers. However, the available well-known techniques for chip cleaning may not be so reliable. Furthermore, it could be necessary to recycle the chip for reuse. Also in this case, an effective recycling technique is required to re-obtain well cleaned sensing surfaces on the chip. This paper presents experimental results on the efficacy and efficiency of the available techniques for initial cleaning and further recycling of micro-fabricated chips. Piranha, plasma, reductive and oxidative cleaning methods were applied and the obtained results were critically compared. Some interesting results were attained by using commonly considered cleaning methodologies. This study outlines oxidative electrochemical cleaning and recycling as the more efficient cleaning procedure for electrochemical based sensor arrays.

  19. Integrated sample-to-detection chip for nucleic acid test assays.

    Science.gov (United States)

    Prakash, R; Pabbaraju, K; Wong, S; Tellier, R; Kaler, K V I S

    2016-06-01

    Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.

  20. Optimal selection of TLD chips

    International Nuclear Information System (INIS)

    Phung, P.; Nicoll, J.J.; Edmonds, P.; Paris, M.; Thompson, C.

    1996-01-01

    Large sets of TLD chips are often used to measure beam dose characteristics in radiotherapy. A sorting method is presented to allow optimal selection of chips from a chosen set. This method considers the variation

  1. Biocoder: A programming language for standardizing and automating biology protocols.

    Science.gov (United States)

    Ananthanarayanan, Vaishnavi; Thies, William

    2010-11-08

    Published descriptions of biology protocols are often ambiguous and incomplete, making them difficult to replicate in other laboratories. However, there is increasing benefit to formalizing the descriptions of protocols, as laboratory automation systems (such as microfluidic chips) are becoming increasingly capable of executing them. Our goal in this paper is to improve both the reproducibility and automation of biology experiments by using a programming language to express the precise series of steps taken. We have developed BioCoder, a C++ library that enables biologists to express the exact steps needed to execute a protocol. In addition to being suitable for automation, BioCoder converts the code into a readable, English-language description for use by biologists. We have implemented over 65 protocols in BioCoder; the most complex of these was successfully executed by a biologist in the laboratory using BioCoder as the only reference. We argue that BioCoder exposes and resolves ambiguities in existing protocols, and could provide the software foundations for future automation platforms. BioCoder is freely available for download at http://research.microsoft.com/en-us/um/india/projects/biocoder/. BioCoder represents the first practical programming system for standardizing and automating biology protocols. Our vision is to change the way that experimental methods are communicated: rather than publishing a written account of the protocols used, researchers will simply publish the code. Our experience suggests that this practice is tractable and offers many benefits. We invite other researchers to leverage BioCoder to improve the precision and completeness of their protocols, and also to adapt and extend BioCoder to new domains.

  2. On-chip generation of heralded photon-number states

    Science.gov (United States)

    Vergyris, Panagiotis; Meany, Thomas; Lunghi, Tommaso; Sauder, Gregory; Downes, James; Steel, M. J.; Withford, Michael J.; Alibart, Olivier; Tanzilli, Sébastien

    2016-10-01

    Beyond the use of genuine monolithic integrated optical platforms, we report here a hybrid strategy enabling on-chip generation of configurable heralded two-photon states. More specifically, we combine two different fabrication techniques, i.e., non-linear waveguides on lithium niobate for efficient photon-pair generation and femtosecond-laser-direct-written waveguides on glass for photon manipulation. Through real-time device manipulation capabilities, a variety of path-coded heralded two-photon states can be produced, ranging from product to entangled states. Those states are engineered with high levels of purity, assessed by fidelities of 99.5 ± 8% and 95.0 ± 8%, respectively, obtained via quantum interferometric measurements. Our strategy therefore stands as a milestone for further exploiting entanglement-based protocols, relying on engineered quantum states, and enabled by scalable and compatible photonic circuits.

  3. Experiment list: SRX110782 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available e3 (ab6002, abcam), Pol II (CTD4H8, Millipore) || chip antibody 1 manufacturer=ab...cam || chip antibody 2=Pol II (CTD4H8, Millipore) || chip antibody 2 manufacturer=Millipore http://dbarchive

  4. Thermometry in dielectrophoresis chips for contact-free cell handling

    International Nuclear Information System (INIS)

    Jaeger, M S; Mueller, T; Schnelle, T

    2007-01-01

    Cell biology applications, protocols in immunology and stem cell research, require that individual cells are handled under strict control of their contacts to other cells or synthetic surfaces. Dielectrophoresis (DEP) in microfluidic chips is an established technique to investigate, group, wash, cultivate and sort cells contact-free under physiological conditions: microelectrode octode cages, versatile dielectrophoretic elements energized with radio frequency electric fields, stably trap single cells or cellular aggregates. For medical applications and cell cultivation, possible side effects of the dielectrophoretic manipulation, such as membrane polarization and Joule heating, have to be quantified. Therefore, we characterized the electric field-induced warming in dielectrophoretic cages using ohmic resistance measurements, fluorometry, liquid crystal beads, infra-red thermography and bubble size thermometry. We compare the results of these techniques with respect to the influences of voltage, electric conductivity of buffer, frequency, cage size and electrode surface. We conclude that in the culture medium thermal effects may be neglected if low voltages and an electric field-reducing phase pattern are used. Our experimental results provide explicit values for estimating the thermal effect on dielectrophoretically caged cells and show that Joule heating is best minimized by optimizing the cage geometry and reducing the buffer conductivity. The results may additionally serve to evaluate and improve theoretical predictions on field-induced effects. Based on present-day chip processing possibilities, DEP is well suited for the manipulation of cells

  5. Chromatin immunoprecipitation (ChIP) of plant transcription factors followed by sequencing (ChIP-SEQ) or hybridization to whole genome arrays (ChIP-CHIP)

    NARCIS (Netherlands)

    Kaufmann, K.; Muiño, J.M.; Østerås, M.; Farinelli, L.; Krajewski, P.; Angenent, G.C.

    2010-01-01

    Chromatin immunoprecipitation (ChIP) is a powerful technique to study interactions between transcription factors (TFs) and DNA in vivo. For genome-wide de novo discovery of TF-binding sites, the DNA that is obtained in ChIP experiments needs to be processed for sequence identification. The sequences

  6. Avaliação da aceitação de "chips" de mandioca Acceptance evaluation of cassava chips

    Directory of Open Access Journals (Sweden)

    Regina Kitagawa Grizotto

    2003-12-01

    Full Text Available Pré-tratamentos como o cozimento, a fermentação natural e a secagem parcial foram aplicados em raízes de mandioca, visando a obtenção de "chips" comestíveis. A avaliação sensorial foi feita com base na aceitação e aparência dos "chips" das variedades IAC Mantiqueira e IAC 576.70. Trinta consumidores potenciais do produto foram selecionados em função da disponibilidade e interesse em participar dos testes. Foi utilizada escala hedônica de 7 pontos, onde os provadores avaliaram as amostras delineadas em blocos casualizados. Os resultados obtidos mostraram que os "chips" controle e pré-cozidos foram aceitos sensorialmente, apresentado médias de 5,1 (gostei ligeiramente para IAC Mantiqueira e 6,0 (gostei moderadamente para IAC 576.70. Os "chips" pré-fermentados de ambas variedades foram rejeitados. Os termos de agrado mais comentados pelos provadores foram "sabor de mandioca", "crocância" e "textura". Os termos de desagrado mais citados incluem "textura dura", "falta sabor de mandioca" e "gosto de óleo". Os provadores consideraram adequada a aparência dos "chips" de ambas variedades, sendo ligeiramente preferida a aparência dos "chips" da IAC 576.70, com exceção dos "chips" cozidos por 8 minutos e os fermentados, rejeitados pelos consumidores. A cor amarela da polpa pode ter influenciado a aceitação da variedade IAC 576.70. A composição centesimal e o teor de fibras na mandioca in natura e, o teor de lipídeos em "chips" de mandioca, também foram apresentados.Pre-treatments such as cooking, natural fermentation and partial drying were applied to cassava roots, aimed at obtaining edible cassava chips. The sensory evaluation was based on the acceptance and appearance of the chips, using the varieties IAC Mantiqueira and IAC 576.70. Thirty potential consumers of the product were selected based on their availability and interest. A 7-point hedonic scale was used, all the judges evaluating all the samples using a randomised

  7. Fully Automated On-Chip Imaging Flow Cytometry System with Disposable Contamination-Free Plastic Re-Cultivation Chip

    Directory of Open Access Journals (Sweden)

    Tomoyuki Kaneko

    2011-06-01

    Full Text Available We have developed a novel imaging cytometry system using a poly(methyl methacrylate (PMMA based microfluidic chip. The system was contamination-free, because sample suspensions contacted only with a flammable PMMA chip and no other component of the system. The transparency and low-fluorescence of PMMA was suitable for microscopic imaging of cells flowing through microchannels on the chip. Sample particles flowing through microchannels on the chip were discriminated by an image-recognition unit with a high-speed camera in real time at the rate of 200 event/s, e.g., microparticles 2.5 μm and 3.0 μm in diameter were differentiated with an error rate of less than 2%. Desired cells were separated automatically from other cells by electrophoretic or dielectrophoretic force one by one with a separation efficiency of 90%. Cells in suspension with fluorescent dye were separated using the same kind of microfluidic chip. Sample of 5 μL with 1 × 106 particle/mL was processed within 40 min. Separated cells could be cultured on the microfluidic chip without contamination. The whole operation of sample handling was automated using 3D micropipetting system. These results showed that the novel imaging flow cytometry system is practically applicable for biological research and clinical diagnostics.

  8. Identification of a research protocol to study orthodontic tooth movement

    Directory of Open Access Journals (Sweden)

    Annalisa Dichicco

    2014-06-01

    Full Text Available Aim: The orthodontic movement is associated with a process of tissue remodeling together with the release of several chemical mediators in periodontal tissues. Each mediator is a potential marker of tooth movement and expresses biological processes as: tissue inflammation and bone remodeling. Different amounts of every mediator are present in several tissues and fluids of the oral cavity. Therefore, there are different methods that allow sampling with several degrees of invasiveness. Chemical mediators are also substances of different molecular nature, and multiple kind of analysis methods allow detection. The purpose of this study was to draft the best research protocol for an optimal study on orthodontic movement efficiency. Methods: An analysis of the international literature have been made, to identify the gold standard of each aspect of the protocol: type of mediator, source and method of sampling and analysis method. Results: From the analysis of the international literature was created an original research protocol for the study and the assessment of the orthodontic movement, by using the biomarkers of the tooth movement. Conclusions: The protocol created is based on the choice of the gold standard of every aspect already analyzed in the literature and in existing protocols for the monitoring of orthodontic tooth movement through the markers of tooth movement. Clinical trials re required for the evaluation and validation of the protocol created.

  9. Chip-to-chip SnO2 nanowire network sensors for room temperature H2 detection

    Science.gov (United States)

    Köck, A.; Brunet, E.; Mutinati, G. C.; Maier, T.; Steinhauer, S.

    2012-06-01

    The employment of nanowires is a very powerful strategy to improve gas sensor performance. We demonstrate a gas sensor device, which is based on silicon chip-to-chip synthesis of ultralong tin oxide (SnO2) nanowires. The sensor device employs an interconnected SnO2 nanowire network configuration, which exhibits a huge surface-to-volume ratio and provides full access of the target gas to the nanowires. The chip-to-chip SnO2 nanowire device is able to detect a H2 concentration of only 20 ppm in synthetic air with ~ 60% relative humidity at room temperature. At an operating temperature of 300°C a concentration of 50 ppm H2 results in a sensitivity of 5%. At this elevated temperature the sensor shows a linear response in a concentration range between 10 ppm and 100 ppm H2. The SnO2-nanowire fabrication procedure based on spray pyrolysis and subsequent annealing is performed at atmospheric pressure, requires no vacuum and allows upscale of the substrate to a wafer size. 3D-integration with CMOS chips is proposed as viable way for practical realization of smart nanowire based gas sensor devices for the consumer market.

  10. ChIP on SNP-chip for genome-wide analysis of human histone H4 hyperacetylation

    Directory of Open Access Journals (Sweden)

    Porter Christopher J

    2007-09-01

    Full Text Available Abstract Background SNP microarrays are designed to genotype Single Nucleotide Polymorphisms (SNPs. These microarrays report hybridization of DNA fragments and therefore can be used for the purpose of detecting genomic fragments. Results Here, we demonstrate that a SNP microarray can be effectively used in this way to perform chromatin immunoprecipitation (ChIP on chip as an alternative to tiling microarrays. We illustrate this novel application by mapping whole genome histone H4 hyperacetylation in human myoblasts and myotubes. We detect clusters of hyperacetylated histone H4, often spanning across up to 300 kilobases of genomic sequence. Using complementary genome-wide analyses of gene expression by DNA microarray we demonstrate that these clusters of hyperacetylated histone H4 tend to be associated with expressed genes. Conclusion The use of a SNP array for a ChIP-on-chip application (ChIP on SNP-chip will be of great value to laboratories whose interest is the determination of general rules regarding the relationship of specific chromatin modifications to transcriptional status throughout the genome and to examine the asymmetric modification of chromatin at heterozygous loci.

  11. Simulating the Effect of Modulated Tool-Path Chip Breaking On Surface Texture and Chip Length

    Energy Technology Data Exchange (ETDEWEB)

    Smith, K.S.; McFarland, J.T.; Tursky, D. A.; Assaid, T. S.; Barkman, W. E.; Babelay, Jr., E. F.

    2010-04-30

    One method for creating broken chips in turning processes involves oscillating the cutting tool in the feed direction utilizing the CNC machine axes. The University of North Carolina at Charlotte and the Y-12 National Security Complex have developed and are refining a method to reliably control surface finish and chip length based on a particular machine's dynamic performance. Using computer simulations it is possible to combine the motion of the machine axes with the geometry of the cutting tool to predict the surface characteristics and map the surface texture for a wide range of oscillation parameters. These data allow the selection of oscillation parameters to simultaneously ensure broken chips and acceptable surface characteristics. This paper describes the machine dynamic testing and characterization activities as well as the computational method used for evaluating and predicting chip length and surface texture.

  12. Decapsulation Method for Flip Chips with Ceramics in Microelectronic Packaging

    Science.gov (United States)

    Shih, T. I.; Duh, J. G.

    2008-06-01

    The decapsulation of flip chips bonded to ceramic substrates is a challenging task in the packaging industry owing to the vulnerability of the chip surface during the process. In conventional methods, such as manual grinding and polishing, the solder bumps are easily damaged during the removal of underfill, and the thin chip may even be crushed due to mechanical stress. An efficient and reliable decapsulation method consisting of thermal and chemical processes was developed in this study. The surface quality of chips after solder removal is satisfactory for the existing solder rework procedure as well as for die-level failure analysis. The innovative processes included heat-sink and ceramic substrate removal, solder bump separation, and solder residue cleaning from the chip surface. In the last stage, particular temperatures were selected for the removal of eutectic Pb-Sn, high-lead, and lead-free solders considering their respective melting points.

  13. Toxicity of invert drilling muds composted with wood/bark chips

    Energy Technology Data Exchange (ETDEWEB)

    Bessie, K. [EBA Engineering Consultants Ltd., Calgary, AB (Canada)

    2006-07-01

    Since the early to mid 1990s, many companies have composted invert (diesel) drilling muds with wood chips/bark chips in the green (forestry) zone as a method of drilling mud treatment. This presentation addressed the toxicity of invert drilling muds composted with wood/bark chips and provided some background on composted invert drilling mud (CIDM). EBA Engineering monitored 22 third-party sites in 2002, some of which were biopiles, and others land treatment areas (LTAs). Active treatment started between 1995 and 1999 and some LTAs were seeded with varying degrees of success. Composted materials had hydrocarbon odour and staining and were very moist. Materials exceeded Alberta Environment guidelines for petroleum hydrocarbons (PHCs) and sometimes barium. Most sites were within areas that had forestry production/wildlife as end land use. Receptors included plants, soil invertebrates by soil contact, and wildlife by ingestion. Stakeholder meetings were held for their input and an ecotoxicity study was developed. Material tested, tests and species used as well as results of the ecotoxicity study were presented. A comparison of results to other EBA composting studies was also given. It was concluded that CIDM affects the reproduction of earthworms and springtails, and plant growth; wood/barks chips themselves can be ecotoxic; and, other compost studies with finely ground sawdust and no bark chips had less ecotoxicity. tabs., figs.

  14. Chip shape and secondary fragmentation through TBM excavation

    International Nuclear Information System (INIS)

    Tsusaka, Kimikazu; Tanimoto, Chikaosa; Ueno, Takaaki; Koizumi, Yu; Nakane, Tatsuto

    2008-01-01

    The chips through TBM tunneling are well-known for one of useful indices to reflect the geological conditions. The flat and elongated chips whose width are equal to the spacing of cutter trace indicate the cutting face with less joints and good practice of TBM excavation with less secondary fragmentation rate. Through a case history in granitic rock, the authors proposed the new index, which is the ratio of length of major axis to thickness. Also the authors studied the relationship between the index and the excavation efficiencies. In conclusion, it was clarified that chips with the new index over 3.5 were generally observed when a TBM drove with less than 30% the secondary fragmentation rate. (author)

  15. Dr. Monaco Examines Lab-on a-Chip

    Science.gov (United States)

    2003-01-01

    Dr. Lisa Monaco, Marshall Space Flight Center's (MSFC's) project scientist for the Lab-on-a-Chip Applications Development (LOCAD) program, examines a lab on a chip. The small dots are actually ports where fluids and chemicals can be mixed or samples can be collected for testing. Tiny channels, only clearly visible under a microscope, form pathways between the ports. Many chemical and biological processes, previously conducted on large pieces of laboratory equipment, can now be performed on these small glass or plastic plates. Monaco and other researchers at MSFC in Huntsville, Alabama, are customizing the chips to be used for many space applications, such as monitoring microbes inside spacecraft and detecting life on other planets. The portable, handheld Lab-on-a Chip Application Development Portable Test System (LOCAD-PTS) made its debut flight aboard Discovery during the STS-116 mission launched December 9, 2006. The system allowed crew members to monitor their environment for problematic contaminants such as yeast, mold, and even E.coli, and salmonella. Once LOCAD-PTS reached the International Space Station (ISS), the Marshall team continued to manage the experiment, monitoring the study from a console in the Payload Operations Center at MSFC. The results of these studies will help NASA researchers refine the technology for future Moon and Mars missions. (NASA/MSFC/D.Stoffer)

  16. Power-aware transceiver design for half-duplex bidirectional chip-to-chip optical interconnects

    International Nuclear Information System (INIS)

    Sangirov Jamshid; Ukaegbu Ikechi Augustine; Lee Tae-Woo; Park Hyo-Hoon; Sangirov Gulomjon

    2013-01-01

    A power-aware transceiver for half-duplex bidirectional chip-to-chip optical interconnects has been designed and fabricated in a 0.13 μm complementary metal–oxide–semiconductor (CMOS) technology. The transceiver can detect the presence and absence of received signals and saves 55% power in Rx enabled mode and 45% in Tx enabled mode. The chip occupies an area of 1.034 mm 2 and achieves a 3-dB bandwidth of 6 GHz and 7 GHz in Tx and Rx modes, respectively. The disabled outputs for the Tx and Rx modes are isolated with 180 dB and 139 dB, respectively, from the enabled outputs. Clear eye diagrams are obtained at 4.25 Gbps for both the Tx and Rx modes. (semiconductor integrated circuits)

  17. A Chip-Capillary Hybrid Device for Automated Transfer of Sample Pre-Separated by Capillary Isoelectric Focusing to Parallel Capillary Gel Electrophoresis for Two-Dimensional Protein Separation

    Science.gov (United States)

    Lu, Joann J.; Wang, Shili; Li, Guanbin; Wang, Wei; Pu, Qiaosheng; Liu, Shaorong

    2012-01-01

    In this report, we introduce a chip-capillary hybrid device to integrate capillary isoelectric focusing (CIEF) with parallel capillary sodium dodecyl sulfate – polyacrylamide gel electrophoresis (SDS-PAGE) or capillary gel electrophoresis (CGE) toward automating two-dimensional (2D) protein separations. The hybrid device consists of three chips that are butted together. The middle chip can be moved between two positions to re-route the fluidic paths, which enables the performance of CIEF and injection of proteins partially resolved by CIEF to CGE capillaries for parallel CGE separations in a continuous and automated fashion. Capillaries are attached to the other two chips to facilitate CIEF and CGE separations and to extend the effective lengths of CGE columns. Specifically, we illustrate the working principle of the hybrid device, develop protocols for producing and preparing the hybrid device, and demonstrate the feasibility of using this hybrid device for automated injection of CIEF-separated sample to parallel CGE for 2D protein separations. Potentials and problems associated with the hybrid device are also discussed. PMID:22830584

  18. A Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection

    OpenAIRE

    Diwei He; Stephen P. Morgan; Dimitrios Trachanis; Jan van Hese; Dimitris Drogoudis; Franco Fummi; Francesco Stefanni; Valerio Guarnieri; Barrie R. Hayes-Gill

    2015-01-01

    Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 ?m CMOS process. The chip includes photodiode, transimpedance amplifier, analogue band-pass filters, analogue-to-digital converters, digital signal processor and LED timing control. The experimentally measured AC and DC characteristics of individual circuits including the DC output voltage of the...

  19. Experiment list: SRX485203 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346544: Rhino ChIP from control germline knock-down ovaries, replicate 2; Drosophila melanogaster; ChIP-Seq ...source_name=Rhino ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult ||... Sex=female || tissue=ovary || germline knock-down=control || chip antibody=custo

  20. Experiment list: SRX485202 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346543: Rhino ChIP from control germline knock-down ovaries, replicate 1; Drosophila melanogaster; ChIP-Seq ...source_name=Rhino ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult ||... Sex=female || tissue=ovary || germline knock-down=control || chip antibody=custo

  1. Experiment list: SRX485210 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 6551: Deadlock ChIP from deadlock germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_name...=Deadlock ChIP from deadlock germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=fe...male || tissue=ovary || germline knock-down=deadlock || chip antibody=custom-made

  2. Experiment list: SRX485211 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346552: Cutoff ChIP from control germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_name=...Cutoff ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female... || tissue=ovary || germline knock-down=control || chip antibody=custom-made rabb

  3. On-chip antenna: Practical design and characterization considerations

    KAUST Repository

    Shamim, Atif; Salama, Khaled N.; Sedky, S.; Soliman, E. A.

    2012-01-01

    This paper highlights the challenges of an emergent field, namely, on-chip antenna design. Consistent with the RF System-on-Chip (SoC) concept, co-design strategy for circuits and on-chip antennas is described. A number of design and layout issues, arising from the highly integrated nature of this kind of systems, are discussed. The characterization difficulties related to on-chip antennas radiation properties are also highlighted. Finally, a novel on-wafer test fixture is proposed to measure the gain and radiation pattern of the on-chip antennas in the anechoic chamber.

  4. On-chip antenna: Practical design and characterization considerations

    KAUST Repository

    Shamim, Atif

    2012-07-28

    This paper highlights the challenges of an emergent field, namely, on-chip antenna design. Consistent with the RF System-on-Chip (SoC) concept, co-design strategy for circuits and on-chip antennas is described. A number of design and layout issues, arising from the highly integrated nature of this kind of systems, are discussed. The characterization difficulties related to on-chip antennas radiation properties are also highlighted. Finally, a novel on-wafer test fixture is proposed to measure the gain and radiation pattern of the on-chip antennas in the anechoic chamber.

  5. Experiment list: SRX485205 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 46546: Rhino ChIP from deadlock germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_name=R...hino ChIP from deadlock germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female ...|| tissue=ovary || germline knock-down=deadlock || chip antibody=custom-made rabb

  6. Experiment list: SRX485212 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346553: Cutoff ChIP from cutoff germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_name=C...utoff ChIP from cutoff germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female |...| tissue=ovary || germline knock-down=cutoff || chip antibody=custom-made rabbit

  7. Experiment list: SRX485206 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346547: Rhino ChIP from cutoff germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_name=Rh...ino ChIP from cutoff germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female || ...tissue=ovary || germline knock-down=cutoff || chip antibody=custom-made rabbit po

  8. Experiment list: SRX485209 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346550: Deadlock ChIP from control germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_nam...e=Deadlock ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=fe...male || tissue=ovary || germline knock-down=control || chip antibody=custom-made

  9. The use of forest chips in Finland

    International Nuclear Information System (INIS)

    Hakkila, P.

    2001-01-01

    International commitments require the industrial world to restrict their greenhouse gas emissions. In Finland, where the annual timber cut per capita is more than ten times the average cut in the other EU countries, the primary means to reduce CO 2 emissions is to replace fossil fuels with forest biomass. The annual consumption of wood-based energy corresponds to 6 million tonnes of oil equivalent (toe) or almost 20% of the total primary energy consumption. The goal is to rise the annual production of wood-based energy to 7.8 million toe by 2010. Substantial part of the targeted increase could be obtained by forest chips produced of unmerchantable small-diameter trees and logging residues. The goal for 2010 is to use 5 million solid m 3 of forest chips, which equals to 0.9 million toe. The use of forest chips is increasing. About 474 000 solid m 3 of forest chips were used as fuel in 1999. At the moment, the growth is rapid especially in cogeneration plants producing both heat and electricity. The growth is based primarily on chips obtained from logging residues. The price of forest chips decreased considerably during the 1990s but the price range remained wide. Chips made of logging residues are cheaper than those made of small trees. The average price of forest chips at the plant, VAT excluded, is about 53 FIM per MWh. In Sweden, the average price is more than 40% higher

  10. Radioactivity changes during burning of peat and chip

    International Nuclear Information System (INIS)

    Hedvall, R.; Erlandsson, B.; Mattsson, S.

    1985-01-01

    The increasing use of peat and chip as fuel materials in fossil-fuel power plants has resulted in the need for information about the change in radionuclides concentration in fuel after combustion. The paper describes a study of natural radionuclides from the uranium- and the thorium series and 40 K, as well as fission products from atmospheric nuclear explosions, in ashes from five peat and chip fuelled power plants in Sweden

  11. Experiment list: SRX485220 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 53 GSM1346561: RNA Polymerase II ChIP from rhino germline knock-down ovaries; Drosophila melanogaster; ChIP-...Seq source_name=RNA Polymerase II ChIP from rhino germline knock-down ovaries || developmental stage=4-6 day...s old adult || Sex=female || tissue=ovary || germline knock-down=rhino || chip an

  12. Experiment list: SRX485204 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346545: Rhino ChIP from rhino germline knock-down ovaries; Drosophila melanogaster; ChIP-Seq source_name=Rhi...no ChIP from rhino germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female || ti...ssue=ovary || germline knock-down=rhino || chip antibody=custom-made rabbit polyc

  13. Experiment list: SRX485208 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 346549: Rhino ChIP from piwi germline knock-down ovaries, replicate 2; Drosophila melanogaster; ChIP-Seq sou...rce_name=Rhino ChIP from piwi germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=f...emale || tissue=ovary || germline knock-down=piwi || chip antibody=custom-made ra

  14. Microsystems for liquid-liquid extraction of radionuclides in the analytical protocols

    International Nuclear Information System (INIS)

    Helle, Gwendolyne

    2014-01-01

    Radiochemical analyses are necessary to numerous steps for nuclear wastes management and for the control of the environment. An analytical protocol generally includes different steps of chemical separations which are lengthy, manual and complicated to implement because of their confinement in glove boxes and because of the hostile chemical and radiochemical media. Thus there is a huge importance to propose innovative and robust solutions to automate these steps but also to reduce the volumes of the radioactive and chemical wastes at the end of the analytical cycle. One solution consists in the miniaturization of the analyses through the use of lab-on-chip. The objective of this thesis work was to propose a rational approach to the conception of separative microsystems for the liquid-liquid extraction of radionuclides. To achieve this, the hydrodynamic behavior as well as the extraction performances have been investigated in one chip for three different chemical systems: Eu(III)-HNO 3 /DMDBTDMA, Eu(III)-AcO(H,Na)-HNO 3 /HDEHP and U(VI)-HCl/Aliquat336. A methodology has been developed for the implementation of the liquid-liquid extraction in micro-system for each chemical system. The influence of various geometric parameters such as channel length or specific interfacial area has been studied and the comparison of the liquid-liquid extraction performances has led to highlight the influence of the phases viscosities ratio on the flows. Thanks to the modeling of both hydrodynamics and mass transfer in micro-system, the criteria related to physical and kinetic properties of the chemical systems have been distinguished to propose a rational conception of tailor-made chips. Finally, several examples of the liquid-liquid extraction implementation in micro-system have been described for analytical applications in the nuclear field: U/Co separation by Aliquat336, Eu/Sm separation by DMDBTDMA or even the coupling between a liquid-liquid extraction chip and the system of

  15. On-chip quantum interference of a superconducting microsphere

    Science.gov (United States)

    Pino, H.; Prat-Camps, J.; Sinha, K.; Prasanna Venkatesh, B.; Romero-Isart, O.

    2018-04-01

    We propose and analyze an all-magnetic scheme to perform a Young’s double slit experiment with a micron-sized superconducting sphere of mass ≳ {10}13 amu. We show that its center of mass could be prepared in a spatial quantum superposition state with an extent of the order of half a micrometer. The scheme is based on magnetically levitating the sphere above a superconducting chip and letting it skate through a static magnetic potential landscape where it interacts for short intervals with quantum circuits. In this way, a protocol for fast quantum interferometry using quantum magnetomechanics is passively implemented. Such a table-top earth-based quantum experiment would operate in a parameter regime where gravitational energy scales become relevant. In particular, we show that the faint parameter-free gravitationally-induced decoherence collapse model, proposed by Diósi and Penrose, could be unambiguously falsified.

  16. Atomic structure of machined semiconducting chips: An x-ray absorption spectroscopy study

    Energy Technology Data Exchange (ETDEWEB)

    Paesler, M.; Sayers, D.

    1988-12-01

    X-ray absorption spectroscopy (XAS) has been used to examine the atomic structure of chips of germanium that were produced by single point diamond machining. It is demonstrated that although the local (nearest neighbor) atomic structure is experimentally quite similar to that of single crystal specimens information from more distant atoms indicates the presence of considerable stress. An outline of the technique is given and the strength of XAS in studying the machining process is demonstrated.

  17. METAL CHIP HEATING PROCESS INVESTIGATION (Part I

    Directory of Open Access Journals (Sweden)

    O. M. Dyakonov

    2007-01-01

    Full Text Available The main calculation methods for heat- and mass transfer in porous heterogeneous medium have been considered. The paper gives an evaluation of the possibility to apply them for calculation of metal chip heating process. It has been shown that a description of transfer processes in a chip has its own specific character that is attributed to difference between thermal and physical properties of chip material and lubricant-coolant components on chip surfaces. It has been determined that the known expressions for effective heat transfer coefficients can be used as basic ones while approaching mutually penetrating continuums. A mathematical description of heat- and mass transfer in chip medium can be considered as a basis of mathematical modeling, numerical solution and parameter optimization of the mentioned processes.

  18. Energy Harvesting Chip and the Chip Based Power Supply Development for a Wireless Sensor Network.

    Science.gov (United States)

    Lee, Dasheng

    2008-12-02

    In this study, an energy harvesting chip was developed to scavenge energy from artificial light to charge a wireless sensor node. The chip core is a miniature transformer with a nano-ferrofluid magnetic core. The chip embedded transformer can convert harvested energy from its solar cell to variable voltage output for driving multiple loads. This chip system yields a simple, small, and more importantly, a battery-less power supply solution. The sensor node is equipped with multiple sensors that can be enabled by the energy harvesting power supply to collect information about the human body comfort degree. Compared with lab instruments, the nodes with temperature, humidity and photosensors driven by harvested energy had variation coefficient measurement precision of less than 6% deviation under low environmental light of 240 lux. The thermal comfort was affected by the air speed. A flow sensor equipped on the sensor node was used to detect airflow speed. Due to its high power consumption, this sensor node provided 15% less accuracy than the instruments, but it still can meet the requirement of analysis for predicted mean votes (PMV) measurement. The energy harvesting wireless sensor network (WSN) was deployed in a 24-hour convenience store to detect thermal comfort degree from the air conditioning control. During one year operation, the sensor network powered by the energy harvesting chip retained normal functions to collect the PMV index of the store. According to the one month statistics of communication status, the packet loss rate (PLR) is 2.3%, which is as good as the presented results of those WSNs powered by battery. Referring to the electric power records, almost 54% energy can be saved by the feedback control of an energy harvesting sensor network. These results illustrate that, scavenging energy not only creates a reliable power source for electronic devices, such as wireless sensor nodes, but can also be an energy source by building an energy efficient

  19. Energy Harvesting Chip and the Chip Based Power Supply Development for a Wireless Sensor Network

    Science.gov (United States)

    Lee, Dasheng

    2008-01-01

    In this study, an energy harvesting chip was developed to scavenge energy from artificial light to charge a wireless sensor node. The chip core is a miniature transformer with a nano-ferrofluid magnetic core. The chip embedded transformer can convert harvested energy from its solar cell to variable voltage output for driving multiple loads. This chip system yields a simple, small, and more importantly, a battery-less power supply solution. The sensor node is equipped with multiple sensors that can be enabled by the energy harvesting power supply to collect information about the human body comfort degree. Compared with lab instruments, the nodes with temperature, humidity and photosensors driven by harvested energy had variation coefficient measurement precision of less than 6% deviation under low environmental light of 240 lux. The thermal comfort was affected by the air speed. A flow sensor equipped on the sensor node was used to detect airflow speed. Due to its high power consumption, this sensor node provided 15% less accuracy than the instruments, but it still can meet the requirement of analysis for predicted mean votes (PMV) measurement. The energy harvesting wireless sensor network (WSN) was deployed in a 24-hour convenience store to detect thermal comfort degree from the air conditioning control. During one year operation, the sensor network powered by the energy harvesting chip retained normal functions to collect the PMV index of the store. According to the one month statistics of communication status, the packet loss rate (PLR) is 2.3%, which is as good as the presented results of those WSNs powered by battery. Referring to the electric power records, almost 54% energy can be saved by the feedback control of an energy harvesting sensor network. These results illustrate that, scavenging energy not only creates a reliable power source for electronic devices, such as wireless sensor nodes, but can also be an energy source by building an energy efficient

  20. Energy Harvesting Chip and the Chip Based Power Supply Development for a Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Dasheng Lee

    2008-12-01

    Full Text Available In this study, an energy harvesting chip was developed to scavenge energy from artificial light to charge a wireless sensor node. The chip core is a miniature transformer with a nano-ferrofluid magnetic core. The chip embedded transformer can convert harvested energy from its solar cell to variable voltage output for driving multiple loads. This chip system yields a simple, small, and more importantly, a battery-less power supply solution. The sensor node is equipped with multiple sensors that can be enabled by the energy harvesting power supply to collect information about the human body comfort degree. Compared with lab instruments, the nodes with temperature, humidity and photosensors driven by harvested energy had variation coefficient measurement precision of less than 6% deviation under low environmental light of 240 lux. The thermal comfort was affected by the air speed. A flow sensor equipped on the sensor node was used to detect airflow speed. Due to its high power consumption, this sensor node provided 15% less accuracy than the instruments, but it still can meet the requirement of analysis for predicted mean votes (PMV measurement. The energy harvesting wireless sensor network (WSN was deployed in a 24-hour convenience store to detect thermal comfort degree from the air conditioning control. During one year operation, the sensor network powered by the energy harvesting chip retained normal functions to collect the PMV index of the store. According to the one month statistics of communication status, the packet loss rate (PLR is 2.3%, which is as good as the presented results of those WSNs powered by battery. Referring to the electric power records, almost 54% energy can be saved by the feedback control of an energy harvesting sensor network. These results illustrate that, scavenging energy not only creates a reliable power source for electronic devices, such as wireless sensor nodes, but can also be an energy source by building an

  1. Mobile Phone Chips Reduce Increases in EEG Brain Activity Induced by Mobile Phone-Emitted Electromagnetic Fields

    Science.gov (United States)

    Henz, Diana; Schöllhorn, Wolfgang I.; Poeggeler, Burkhard

    2018-01-01

    Recent neurophysiological studies indicate that exposure to electromagnetic fields (EMFs) generated by mobile phone radiation can exert effects on brain activity. One technical solution to reduce effects of EMFs in mobile phone use is provided in mobile phone chips that are applied to mobile phones or attached to their surfaces. To date, there are no systematical studies on the effects of mobile phone chip application on brain activity and the underlying neural mechanisms. The present study investigated whether mobile phone chips that are applied to mobile phones reduce effects of EMFs emitted by mobile phone radiation on electroencephalographic (EEG) brain activity in a laboratory study. Thirty participants volunteered in the present study. Experimental conditions (mobile phone chip, placebo chip, no chip) were set up in a randomized within-subjects design. Spontaneous EEG was recorded before and after mobile phone exposure for two 2-min sequences at resting conditions. During mobile phone exposure, spontaneous EEG was recorded for 30 min during resting conditions, and 5 min during performance of an attention test (d2-R). Results showed increased activity in the theta, alpha, beta and gamma bands during EMF exposure in the placebo and no chip conditions. Application of the mobile phone chip reduced effects of EMFs on EEG brain activity and attentional performance significantly. Attentional performance level was maintained regarding number of edited characters. Further, a dipole analysis revealed different underlying activation patterns in the chip condition compared to the placebo chip and no chip conditions. Finally, a correlational analysis for the EEG frequency bands and electromagnetic high-frequency (HF) emission showed significant correlations in the placebo chip and no chip condition for the theta, alpha, beta, and gamma bands. In the chip condition, a significant correlation of HF with the theta and alpha bands, but not with the beta and gamma bands was

  2. Mobile Phone Chips Reduce Increases in EEG Brain Activity Induced by Mobile Phone-Emitted Electromagnetic Fields.

    Science.gov (United States)

    Henz, Diana; Schöllhorn, Wolfgang I; Poeggeler, Burkhard

    2018-01-01

    Recent neurophysiological studies indicate that exposure to electromagnetic fields (EMFs) generated by mobile phone radiation can exert effects on brain activity. One technical solution to reduce effects of EMFs in mobile phone use is provided in mobile phone chips that are applied to mobile phones or attached to their surfaces. To date, there are no systematical studies on the effects of mobile phone chip application on brain activity and the underlying neural mechanisms. The present study investigated whether mobile phone chips that are applied to mobile phones reduce effects of EMFs emitted by mobile phone radiation on electroencephalographic (EEG) brain activity in a laboratory study. Thirty participants volunteered in the present study. Experimental conditions (mobile phone chip, placebo chip, no chip) were set up in a randomized within-subjects design. Spontaneous EEG was recorded before and after mobile phone exposure for two 2-min sequences at resting conditions. During mobile phone exposure, spontaneous EEG was recorded for 30 min during resting conditions, and 5 min during performance of an attention test (d2-R). Results showed increased activity in the theta, alpha, beta and gamma bands during EMF exposure in the placebo and no chip conditions. Application of the mobile phone chip reduced effects of EMFs on EEG brain activity and attentional performance significantly. Attentional performance level was maintained regarding number of edited characters. Further, a dipole analysis revealed different underlying activation patterns in the chip condition compared to the placebo chip and no chip conditions. Finally, a correlational analysis for the EEG frequency bands and electromagnetic high-frequency (HF) emission showed significant correlations in the placebo chip and no chip condition for the theta, alpha, beta, and gamma bands. In the chip condition, a significant correlation of HF with the theta and alpha bands, but not with the beta and gamma bands was

  3. A contact-lens-shaped IC chip technology

    International Nuclear Information System (INIS)

    Liu, Ching-Yu; Yang, Frank; Teng, Chih-Chiao; Fan, Long-Sheng

    2014-01-01

    We report on novel contact-lens-shaped silicon integrated circuit chip technology for applications such as forming a conforming retinal prosthesis. This is achieved by means of patterning thin films of high residual stress on top of a shaped thin silicon substrate. Several strategies are employed to achieve curvatures of various amounts. Firstly, high residual stress on a thin film makes a thin chip deform into a designed three-dimensional shape. Also, a series of patterned stress films and ‘petal-shaped’ chips were fabricated and analyzed. Large curvatures can also be formed and maintained by the packaging process of bonding the chips to constraining elements such as thin-film polymer ring structures. As a demonstration, a complementary metal oxide semiconductor transistor (CMOS) image-sensing retina chip is made into a contact-lens shape conforming to a human eyeball 12.5 mm in radius. This non-planar and flexible chip technology provides a desirable device surface interface to soft tissues or non-planar bio surfaces and opens up many other possibilities for biomedical applications. (paper)

  4. Experiment list: SRX485222 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 4me2 ChIP from control germline knock-down ovaries, replicate 2; Drosophila melanogaster; ChIP-Seq source_na...me=H3K4me2 ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=fe...male || tissue=ovary || germline knock-down=control || chip antibody=Anti-dimethy

  5. Experiment list: SRX485221 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available K4me2 ChIP from control germline knock-down ovaries, replicate 1; Drosophila melanogaster; ChIP-Seq source_n...ame=H3K4me2 ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=f...emale || tissue=ovary || germline knock-down=control || chip antibody=Anti-dimeth

  6. Rework of flip chip bonded radiation pixel detectors

    International Nuclear Information System (INIS)

    Vaehaenen, S.; Heikkinen, H.; Pohjonen, H.; Salonen, J.; Savolainen-Pulli, S.

    2008-01-01

    In this paper, some practical aspects of reworking flip chip hybridized pixel detectors are discussed. As flip chip technology has been advancing in terms of placement accuracy and reliability, large-area hybrid pixel detectors have been developed. The area requirements are usually fulfilled by placing several readout chips (ROCs) on single sensor chip. However, as the number of ROCs increases, the probability of failure in the hybridization process and the ROC operation also increases. Because high accuracy flip chip bonding takes time, a significant part of the price of a pixel detector comes from the flip chip assembly process itself. As large-area detector substrates are expensive, and many flip chip placements are required, the price of an assembled detector can become very high. In a typical case, there is just one bad ROC (out of several) on a faulty detector to be replaced. Considering the high price of pixel detectors and the fact that reworking faulty ROCs does not take much longer than the original placement, it is worthwhile to investigate the feasibility of a rework process

  7. Rework of flip chip bonded radiation pixel detectors

    Energy Technology Data Exchange (ETDEWEB)

    Vaehaenen, S. [VTT MEMS and Micropackaging, Espoo 02150 (Finland)], E-mail: sami.vahanen@vtt.fi; Heikkinen, H.; Pohjonen, H.; Salonen, J.; Savolainen-Pulli, S. [VTT MEMS and Micropackaging, Espoo 02150 (Finland)

    2008-06-11

    In this paper, some practical aspects of reworking flip chip hybridized pixel detectors are discussed. As flip chip technology has been advancing in terms of placement accuracy and reliability, large-area hybrid pixel detectors have been developed. The area requirements are usually fulfilled by placing several readout chips (ROCs) on single sensor chip. However, as the number of ROCs increases, the probability of failure in the hybridization process and the ROC operation also increases. Because high accuracy flip chip bonding takes time, a significant part of the price of a pixel detector comes from the flip chip assembly process itself. As large-area detector substrates are expensive, and many flip chip placements are required, the price of an assembled detector can become very high. In a typical case, there is just one bad ROC (out of several) on a faulty detector to be replaced. Considering the high price of pixel detectors and the fact that reworking faulty ROCs does not take much longer than the original placement, it is worthwhile to investigate the feasibility of a rework process.

  8. Multimedia-Based Chip Design Education.

    Science.gov (United States)

    Catalkaya, Tamer; Golze, Ulrich

    This paper focuses on multimedia computer-based training programs on chip design. Their development must be fast and economical, in order to be affordable by technical university institutions. The self-produced teaching program Illusion, which demonstrates a monitor controller as an example of a small but complete chip design, was implemented to…

  9. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols.

    Science.gov (United States)

    Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen

    2010-12-01

    The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.

  10. A single chip with multiple talents

    CERN Multimedia

    Francesco Poppi

    2010-01-01

    The Medipix chips developed at CERN are being used in a variety of fields: from medicine to education and back to high-tech engineering. The scene is set for a bright future for this versatile technology.   The Medipix chip. It didn’t take long for a brilliant team of physicists and engineers who were working on pixel detectors for the LHC to realize that the technology had great potential in medical imaging. This was the birth of the Medipix project. Fifteen years later, with the collaboration of 18 research institutes, the team has produced an advanced version of the initial ideas: Medipix3 is a device that can measure very accurately the position and energy of the photons (one by one) that hit the associated detector. Radiography and computed tomography (CT) use X-ray photons to study the human body. The different energies of the photons in the beam can be thought of as the colours of the X-ray spectrum. This is why the use of Medipix3 chips in such diagnostic techniques is referred...

  11. A study on oxidation treatment of uranium metal chip under controlling atmosphere for safe storage

    International Nuclear Information System (INIS)

    Kim, Chang Kyu; Ji, Chul Goo; Bae, Sang Oh; Woo, Yoon Myeoung; Kim, Jong Goo; Ha, Yeong Keong

    2011-01-01

    The U metal chips generated in developing nuclear fuel and a gamma radioisotope shield have been stored under immersion of water in KAERI. When the water of the storing vessels vaporizes or drains due to unexpected leaking, the U metal chips are able to open to air. A new oxidation treatment process was raised for a long time safe storage with concepts of drying under vacuum, evaporating the containing water and organic material with elevating temperature, and oxidizing the uranium metal chips at an appropriate high temperature under conditions of controlling the feeding rate of oxygen gas. In order to optimize the oxidation process the uranium metal chips were completely dried at higher temperature than 300 .deg. C and tested for oxidation at various temperatures, which are 300 .deg. C, 400 .deg. C, and 500 .deg. C. When the oxidation temperature was 400 .deg. C, the oxidized sample for 7 hours showed a temperature rise of 60 .deg. C in the self-ignition test. But the oxidized sample for 14 hours revealed a slight temperature rise of 7 .deg. C representing a stable behavior in the self-ignition test. When the temperature was 500 .deg. C, the shorter oxidation for 7 hours appeared to be enough because the self-ignition test represented no temperature rise. By using several chemical analyses such as carbon content determination, X-ray deflection (XRD), Infrared spectra (IR) and Thermal gravimetric analysis (TGA) on the oxidation treated samples, the results of self-ignition test of new oxidation treatment process for U metal chip were interpreted and supported

  12. Cassava chips quality as influenced by cultivar, blanching time and ...

    African Journals Online (AJOL)

    Currently, fried cassava chips and crisps are increasingly being consumed as snacks; and fried cassava chips are produced by street processors. The quality and safety of these products is not known, therefore, the current study was to establish the influence of cassava cultivar, blanching time and slice thickness on quality ...

  13. Experiment list: SRX485218 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available K9me3 ChIP from piwi germline knock-down ovaries, replicate 2; Drosophila melanogaster; ChIP-Seq source_name...=H3K9me3 ChIP from piwi germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female ...|| tissue=ovary || germline knock-down=piwi || chip antibody=Histone H3K9me3 anti

  14. Experiment list: SRX485213 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available K9me3 ChIP from control germline knock-down ovaries, replicate 1; Drosophila melanogaster; ChIP-Seq source_n...ame=H3K9me3 ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=f...emale || tissue=ovary || germline knock-down=control || chip antibody=Histone H3K

  15. Experiment list: SRX485214 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available K9me3 ChIP from control germline knock-down ovaries, replicate 2; Drosophila melanogaster; ChIP-Seq source_n...ame=H3K9me3 ChIP from control germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=f...emale || tissue=ovary || germline knock-down=control || chip antibody=Histone H3K

  16. 75 FR 16149 - Medicaid and CHIP Programs; Meeting of the CHIP Working Group-April 26, 2010

    Science.gov (United States)

    2010-03-31

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Medicare & Medicaid Services [CMS-2312-N] DEPARTMENT OF LABOR Employee Benefits Security Administration Medicaid and CHIP Programs; Meeting of the CHIP Working Group-- April 26, 2010 AGENCIES: Centers for Medicare & Medicaid Services (CMS), Department of...

  17. Study and development of a remote biometric authentication protocol

    OpenAIRE

    Bistarelli, Stefano; Claudio, Viti

    2003-01-01

    This paper reports the phases of study and implementation of a remote biometric authentication protocol developed during my internship at the I.i.t. of the C.n.r. in Pisa. Starting from the study of authentication history we had a look from the first system used since the 60ies to the latest technology; this helped us understand how we could realize a demonstration working protocol that could achieve a web remote authentication granting good reliability: to do this we choosed to modify the SS...

  18. Atom chips: mesoscopic physics with cold atoms

    International Nuclear Information System (INIS)

    Krueger, P.; Wildermuth, S.; Hofferberth, S.; Haller, E.; GAllego Garcia, D.; Schmiedmayer, J.

    2005-01-01

    Full text: Cold neutral atoms can be controlled and manipulated in microscopic potentials near surfaces of atom chips. These integrated micro-devices combine the known techniques of atom optics with the capabilities of well established micro- and nanofabrication technology. In analogy to electronic microchips and integrated fiber optics, the concept of atom chips is suitable to explore the domain of mesoscopic physics with matter waves. We use current and charge carrying structures to form complex potentials with high spatial resolution only microns from the surface. In particular, atoms can be confined to an essentially one-dimensional motion. In this talk, we will give an overview of our experiments studying the manipulation of both thermal atoms and BECs on atom chips. First experiments in the quasi one-dimensional regime will be presented. These experiments profit from strongly reduced residual disorder potentials caused by imperfections of the chip fabrication with respect to previously published experiments. This is due to our purely lithographic fabrication technique that proves to be advantageous over electroplating. We have used one dimensionally confined BECs as an ultra-sensitive probe to characterize these potentials. These smooth potentials allow us to explore various aspects of the physics of degenerate quantum gases in low dimensions. (author)

  19. Human iPSC-Derived Endothelial Cells and Microengineered Organ-Chip Enhance Neuronal Development

    Directory of Open Access Journals (Sweden)

    Samuel Sances

    2018-04-01

    Full Text Available Summary: Human stem cell-derived models of development and neurodegenerative diseases are challenged by cellular immaturity in vitro. Microengineered organ-on-chip (or Organ-Chip systems are designed to emulate microvolume cytoarchitecture and enable co-culture of distinct cell types. Brain microvascular endothelial cells (BMECs share common signaling pathways with neurons early in development, but their contribution to human neuronal maturation is largely unknown. To study this interaction and influence of microculture, we derived both spinal motor neurons and BMECs from human induced pluripotent stem cells and observed increased calcium transient function and Chip-specific gene expression in Organ-Chips compared with 96-well plates. Seeding BMECs in the Organ-Chip led to vascular-neural interaction and specific gene activation that further enhanced neuronal function and in vivo-like signatures. The results show that the vascular system has specific maturation effects on spinal cord neural tissue, and the use of Organ-Chips can move stem cell models closer to an in vivo condition. : Sances et al. combine Organ-Chip technology with human induced pluripotent stem cell-derived spinal motor neurons to study the maturation effects of Organ-Chip culture. By including microvascular cells also derived from the same patient line, the authors show enhancement of neuronal function, reproduction of vascular-neuron pathways, and specific gene activation that resembles in vivo spinal cord development. Keywords: organ-on-chip, spinal cord, iPSC, disease modeling, amyotrophic lateral sclerosis, microphysiological system, brain microvascular endothelial cells, spinal motor neurons, vasculature, microfluidic device

  20. Studying protocol-based pain management in the emergency department

    Directory of Open Access Journals (Sweden)

    Akkamahadevi Patil

    2017-01-01

    Full Text Available Background: Majority of the patients presenting to emergency department (ED have pain. ED oligoanalgesia remains a challenge. Aims: This study aims to study the effect of implementing a protocol-based pain management in the ED on (1 time to analgesia and (2 adequacy of analgesia obtained. Settings and Design: Cross-sectional study in the ED. Methods: Patients aged 18–65 years of age with pain of numeric rating scale (NRS ≥4 were included. A series of 100 patients presenting before introduction of the protocol-based pain management were grouped “pre-protocol,” and managed as per existing practice. Following this, a protocol for management of all patients presenting to ED with pain was implemented. Another series of 100 were grouped as “post-protocol” and managed as per the new pain management protocol. The data of patients from both the groups were collected and analyzed. Statistical Analysis Used: Descriptive statistical tests such as percentage, mean and standard deviation and inferential statistical tests such as Pearson coefficient, Student's t-test were applied. Differences were interpreted as significant when P < 0.05. Results: Mean time to administer analgesic was significantly lesser in the postprotocol group (preprotocol 20.30 min vs. postprotocol 13.05 min; P < 0.001. There was significant difference in the pain relief achieved (change in NRS between the two groups, with greater pain relief achieved in the postprotocol group (preprotocol group 4.6800 vs. postprotocol group 5.3600; P < 0.001. Patients' rating of pain relief (assessed on E5 scale was significantly higher in the postprotocol group (preprotocol 3.91 vs. postprotocol 4.27; P = 0.001. Patients' satisfaction (North American Spine Society scale with the overall treatment was also compared and found to be significantly higher in postprotocol group (mean: preprotocol 1.59 vs. postprotocol 1.39; P = 0.008. Conclusion: Protocol-based pain management provided timely and

  1. Individualized Pixel Synthesis and Characterization of Combinatorial Materials Chips

    Directory of Open Access Journals (Sweden)

    Xiao-Dong Xiang

    2015-06-01

    Full Text Available Conventionally, an experimentally determined phase diagram requires studies of phase formation at a range of temperatures for each composition, which takes years of effort from multiple research groups. Combinatorial materials chip technology, featuring high-throughput synthesis and characterization, is able to determine the phase diagram of an entire composition spread of a binary or ternary system at a single temperature on one materials library, which, though significantly increasing efficiency, still requires many libraries processed at a series of temperatures in order to complete a phase diagram. In this paper, we propose a “one-chip method” to construct a complete phase diagram by individually synthesizing each pixel step by step with a progressive pulse of energy to heat at different temperatures while monitoring the phase evolution on the pixel in situ in real time. Repeating this process pixel by pixel throughout the whole chip allows the entire binary or ternary phase diagram to be mapped on one chip in a single experiment. The feasibility of this methodology is demonstrated in a study of a Ge-Sb-Te ternary alloy system, on which the amorphous-crystalline phase boundary is determined.

  2. Study on Improving Thickness Uniformity of Microfluidic Chip Mold in the Electroforming Process

    Directory of Open Access Journals (Sweden)

    Liqun Du

    2016-01-01

    Full Text Available Electroformed microfluidic chip mold faces the problem of uneven thickness, which decreases the dimensional accuracy of the mold, and increases the production cost. To fabricate a mold with uniform thickness, two methods are investigated. Firstly, experiments are carried out to study how the ultrasonic agitation affects the thickness uniformity of the mold. It is found that the thickness uniformity is maximally improved by about 30% after 2 h electroforming under 200 kHz and 500 W ultrasonic agitation. Secondly, adding a second cathode, a method suitable for long-time electroforming is studied by numerical simulation. The simulation results show that with a 4 mm width second cathode used, the thickness uniformity is improved by about 30% after 2 h of electroforming, and that with electroforming time extended, the thickness uniformity is improved more obviously. After 22 h electroforming, the thickness uniformity is increased by about 45%. Finally, by comparing two methods, the method of adding a second cathode is chosen, and a microfluidic chip mold is made with the help of a specially designed second cathode. The result shows that the thickness uniformity of the mold is increased by about 50%, which is in good agreement with the simulation results.

  3. Numerical study on fabricating rectangle microchannel in microfluidic chips by glass molding process

    Science.gov (United States)

    Wang, Tao; Chen, Jing; Zhou, Tianfeng

    2017-09-01

    This paper studied the glass molding process (GMP) for fabricating a typical microstructure of glass microfluidic chips, i. e., rectangle microchannel, on soda-lime glass by finite element method. More than 100 models were established on the platform of Abaqus/Standard. The influence of parameters, i. e., temperature, aspect ratio, side wall angle and friction coefficient on deformation were studied, and the predicted morphology of the molded microchannel were presented as well. The research could provide fundamental experience for optimizing GMP process in the future.

  4. Research of Dielectric Breakdown Micro fluidic Sampling Chip

    International Nuclear Information System (INIS)

    Jiang, F.; Lei, Y.; Yu, J.

    2013-01-01

    Micro fluidic chip is mainly driven electrically by external electrode and array electrode, but there are certain disadvantages in both of ways, which affect the promotion and application of micro fluidic technology. This paper discusses a scheme that uses the conductive solution in a microchannel made by PDMS, replacing electrodes and the way of dielectric breakdown to achieve microfluidic chip driver. It could reduce the driving voltage and simplify the chip production process. To prove the feasibility of this method, we produced a micro fluidic chip used in PDMS material with the lithography technology and experimented it. The results showed that using the dielectric breakdown to achieve microfluidic chip driver is feasible, and it has certain application prospect.

  5. A study of SEU-tolerant latches for the RD53A chip

    CERN Document Server

    Fougeron, Denis

    2018-01-01

    The RD53 collaboration was established to develop the next generation of pixel readout chips needed by ATLAS and CMS at the HL-LHC and requiring extreme rate and radiation tolerance. The 65 nm CMOS process has been adopted in order to satisfy the high level of integration requirement. However, the SEU immunity should be carefully considered for a deep submicron process like the 65 nm. Indeed, the device dimensions are small and the capacitance of the storage nodes becomes very low. A chip prototype including different SEU tolerant structures was designed in a 65 nm technology. Several proton irradiation tests were carried out in order to estimate the SEU tolerance of the proposed structures and the level of improvement comparing with a standard architecture.

  6. Experiment list: SRX485216 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 3K9me3 ChIP from rhino germline knock-down ovaries, replicate 2; Drosophila melanogaster; ChIP-Seq source_na...me=H3K9me3 ChIP from rhino germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=fema...le || tissue=ovary || germline knock-down=rhino || chip antibody=Histone H3K9me3

  7. Experiment list: SRX485215 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available K9me3 ChIP from rhino germline knock-down ovaries, replicate 1; Drosophila melanogaster; ChIP-Seq source_nam...e=H3K9me3 ChIP from rhino germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=femal...e || tissue=ovary || germline knock-down=rhino || chip antibody=Histone H3K9me3 a

  8. Experiment list: SRX485217 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 3K9me3 ChIP from piwi germline knock-down ovaries, replicate 1; Drosophila melanogaster; ChIP-Seq source_nam...e=H3K9me3 ChIP from piwi germline knock-down ovaries || developmental stage=4-6 days old adult || Sex=female... || tissue=ovary || germline knock-down=piwi || chip antibody=Histone H3K9me3 ant

  9. Real-time and time-integrated PM2.5 and CO from prescribed burns in chipped and non-chipped plots: firefighter and community exposure and health implications

    Science.gov (United States)

    Luke P. Naeher; Gary L. Achtemeier; Jeff S. Glitzenstein; Donna R. Streng; David Macintosh

    2006-01-01

    In this study, smoke data were collected from two plots located on the Francis Marion National Forest in South Carolina during prescribed burns on 12 February 2003. One of the plots had been subjected to mechanical chipping, the other was not. This study is part of a larger investigation of fire behavior related to mechanical chipping, parts of which are presented...

  10. Study on Cloud Security Based on Trust Spanning Tree Protocol

    Science.gov (United States)

    Lai, Yingxu; Liu, Zenghui; Pan, Qiuyue; Liu, Jing

    2015-09-01

    Attacks executed on Spanning Tree Protocol (STP) expose the weakness of link layer protocols and put the higher layers in jeopardy. Although the problems have been studied for many years and various solutions have been proposed, many security issues remain. To enhance the security and credibility of layer-2 network, we propose a trust-based spanning tree protocol aiming at achieving a higher credibility of LAN switch with a simple and lightweight authentication mechanism. If correctly implemented in each trusted switch, the authentication of trust-based STP can guarantee the credibility of topology information that is announced to other switch in the LAN. To verify the enforcement of the trusted protocol, we present a new trust evaluation method of the STP using a specification-based state model. We implement a prototype of trust-based STP to investigate its practicality. Experiment shows that the trusted protocol can achieve security goals and effectively avoid STP attacks with a lower computation overhead and good convergence performance.

  11. Thermal-Aware Scheduling for Future Chip Multiprocessors

    Directory of Open Access Journals (Sweden)

    Pedro Trancoso

    2007-04-01

    Full Text Available The increased complexity and operating frequency in current single chip microprocessors is resulting in a decrease in the performance improvements. Consequently, major manufacturers offer chip multiprocessor (CMP architectures in order to keep up with the expected performance gains. This architecture is successfully being introduced in many markets including that of the embedded systems. Nevertheless, the integration of several cores onto the same chip may lead to increased heat dissipation and consequently additional costs for cooling, higher power consumption, decrease of the reliability, and thermal-induced performance loss, among others. In this paper, we analyze the evolution of the thermal issues for the future chip multiprocessor architectures and show that as the number of on-chip cores increases, the thermal-induced problems will worsen. In addition, we present several scenarios that result in excessive thermal stress to the CMP chip or significant performance loss. In order to minimize or even eliminate these problems, we propose thermal-aware scheduler (TAS algorithms. When assigning processes to cores, TAS takes their temperature and cooling ability into account in order to avoid thermal stress and at the same time improve the performance. Experimental results have shown that a TAS algorithm that considers also the temperatures of neighboring cores is able to significantly reduce the temperature-induced performance loss while at the same time, decrease the chip's temperature across many different operation and configuration scenarios.

  12. GaN-based integrated photonics chip with suspended LED and waveguide

    Science.gov (United States)

    Li, Xin; Wang, Yongjin; Hane, Kazuhiro; Shi, Zheng; Yan, Jiang

    2018-05-01

    We propose a GaN-based integrated photonics chip with suspended LED and straight waveguide with different geometric parameters. The integrated photonics chip is prepared by double-side process. Light transmission performance of the integrated chip verse current is quantitatively analyzed by capturing light transmitted to waveguide tip and BPM (beam propagation method) simulation. Reduction of the waveguide width from 8 μm to 4 μm results in an over linear reduction of the light output power while a doubling of the length from 250 μm to 500 μm only results in under linear decrease of the output power. Free-space data transmission with 80 Mbps random binary sequence of the integrated chip is capable of achieving high speed data transmission via visible light. This study provides a potential approach for GaN-based integrated photonics chip as micro light source and passive optical device in VLC (visible light communication).

  13. Chip bonding of low-melting eutectic alloys by transmitted laser radiation

    Science.gov (United States)

    Hoff, Christian; Venkatesh, Arjun; Schneider, Friedrich; Hermsdorf, Jörg; Bengsch, Sebastian; Wurz, Marc C.; Kaierle, Stefan; Overmeyer, Ludger

    2017-06-01

    Present-day thermode bond systems for the assembly of radio-frequency identification (RFID) chips are mechanically inflexible, difficult to control, and will not meet future manufacturing challenges sufficiently. Chip bonding, one of the key processes in the production of integrated circuits (ICs), has a high potential for optimization with respect to process duration and process flexibility. For this purpose, the technologies used, so far, are supposed to be replaced by a transmission laser-bonding process using low-melting eutectic alloys. In this study, successful bonding investigations of mock silicon chips and of RFID chips on flexible polymer substrates are presented using the low-melting eutectic alloy, 52In48Sn, and a laser with a wavelength of 2 μm.

  14. 75 FR 30046 - Medicaid and CHIP Programs; Meeting of the CHIP Working Group-June 14, 2010

    Science.gov (United States)

    2010-05-28

    ..., Employee Benefits Security Administration, DOL at (202) 693-8335. News media representatives must contact... eligible for benefits under titles XIX or XXI of the Social Security Act (the Act) to enable them to enroll...] DEPARTMENT OF LABOR Employee Benefits Security Administration Medicaid and CHIP Programs; Meeting of the CHIP...

  15. Instrument for measuring moisture in wood chips

    Energy Technology Data Exchange (ETDEWEB)

    Werme, L

    1980-06-01

    A method to determine the moisture content in wood chips, in batch and on-line, has been investigated. The method can be used for frozen and non frozen chips. Samples of wood chips are thawn and dryed with microwaves. During the drying the sample is weighed continously and the rate of drying is measured. The sample is dried t 10 percent moisture content. The result is extrapolated to the drying rate zero. The acccuracy at the method is 1.6 to 1.7 percent for both frozen and non frozen chips. The accuracy of the method is considered acceptable, but sofisticated sampling equipment is necessary. This makes the method too complex to make the instrument marketable.

  16. On-chip power delivery and management

    CERN Document Server

    Vaisband, Inna P; Popovich, Mikhail; Mezhiba, Andrey V; Köse, Selçuk; Friedman, Eby G

    2016-01-01

    This book describes methods for distributing power in high speed, high complexity integrated circuits with power levels exceeding many tens of watts and power supplies below a volt. It provides a broad and cohesive treatment of power delivery and management systems and related design problems, including both circuit network models and design techniques for on-chip decoupling capacitors, providing insight and intuition into the behavior and design of on-chip power distribution systems. Organized into subareas to provide a more intuitive flow to the reader, this fourth edition adds more than a hundred pages of new content, including inductance models for interdigitated structures, design strategies for multi-layer power grids, advanced methods for efficient power grid design and analysis, and methodologies for simultaneously placing on-chip multiple power supplies and decoupling capacitors. The emphasis of this additional material is on managing the complexity of on-chip power distribution networks.

  17. Materials Characterization of CIGS solar cells on Top of CMOS chips

    NARCIS (Netherlands)

    Lu, J.; Liu, W.; Kovalgin, A.Y.; Sun, Y.; Schmitz, J.; Venkatasubramanian, R.; Radousky, H.; Liang, H.

    2011-01-01

    In the current work, we present a detailed study on the material properties of the CIGS layers, fabricated on top of the CMOS chips, and compare the results with the fabrication on standard glass substrates. Almost identical elemental composition on both glass and CMOS chips (within measurement

  18. Modified precision-husky progrind H-3045 for chipping biomass

    Science.gov (United States)

    Dana Mitchell; Fernando Seixas; John. Klepac

    2008-01-01

    A specific size of whole tree chip was needed to co-mill wood chips with coal. The specifications are stringent because chips must be mixed with coal, as opposed to a co-firing process. In co-firing, two raw products are conveyed separately to a boiler. In co-milling, such as at Alabama Power's Plant Gadsden, the chip and coal mix must pass through a series of...

  19. Marker Pen Lithography for Flexible and Curvilinear On-Chip Energy Storage

    KAUST Repository

    Jiang, Qiu

    2015-07-14

    On-chip energy storage using microsupercapacitors can serve the dual role of supplementing batteries for pulse power delivery, and replacement of bulky electrolytic capacitors in ac-line filtering applications. Despite complexity and processing costs, microfabrication techniques are being employed in fabricating a great variety of microsupercapacitor devices. Here, a simple, cost-effective, and versatile strategy is proposed to fabricate flexible and curvilinear microsupercapacitors (MSCs). The protocol involves writing sacrificial ink patterns using commercial marker pens on rigid, flexible, and curvilinear substrates. It is shown that this process can be used in both lift-off and etching modes, and the possibility of multistack design of active materials using simple pen lithography is demonstrated. As a prototype, this method is used to produce conducting polymer MSCs involving both poly(3,4-ethylenedioxythiophene), polyaniline, and metal oxide (MnO2) electrode materials. Typical values of energy density in the range of 5-11 mWh cm-3 at power densities of 1-6 W cm-3 are achieved, which is comparable to thin film batteries and superior to the carbon and metal oxide based microsupercapacitors reported in the literature. The simplicity and broad scope of this innovative strategy can open up new avenues for easy and scalable fabrication of a wide variety of on-chip energy storage devices. © 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim.

  20. Marker Pen Lithography for Flexible and Curvilinear On-Chip Energy Storage

    KAUST Repository

    Jiang, Qiu; Kurra, Narendra; Alshareef, Husam N.

    2015-01-01

    On-chip energy storage using microsupercapacitors can serve the dual role of supplementing batteries for pulse power delivery, and replacement of bulky electrolytic capacitors in ac-line filtering applications. Despite complexity and processing costs, microfabrication techniques are being employed in fabricating a great variety of microsupercapacitor devices. Here, a simple, cost-effective, and versatile strategy is proposed to fabricate flexible and curvilinear microsupercapacitors (MSCs). The protocol involves writing sacrificial ink patterns using commercial marker pens on rigid, flexible, and curvilinear substrates. It is shown that this process can be used in both lift-off and etching modes, and the possibility of multistack design of active materials using simple pen lithography is demonstrated. As a prototype, this method is used to produce conducting polymer MSCs involving both poly(3,4-ethylenedioxythiophene), polyaniline, and metal oxide (MnO2) electrode materials. Typical values of energy density in the range of 5-11 mWh cm-3 at power densities of 1-6 W cm-3 are achieved, which is comparable to thin film batteries and superior to the carbon and metal oxide based microsupercapacitors reported in the literature. The simplicity and broad scope of this innovative strategy can open up new avenues for easy and scalable fabrication of a wide variety of on-chip energy storage devices. © 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim.

  1. Experiment list: SRX319558 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available | cell type=mouse embryonic stem cells || genotype/variation=expressing control BirA || chip beads=Dynabeads... MyOne Streptavidin T1 || chip beads vendor=Invitrogen http://dbarchive.bioscienc

  2. Experiment list: SRX319557 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available se embryonic stem cells || genotype/variation=expressing Flag-bio tagged Nanog || chip beads=Dynabeads MyOne... Streptavidin T1 || chip beads vendor=Invitrogen http://dbarchive.biosciencedbc.j

  3. Characteristics of wood chip fuel demand and supply in south-west Japan

    Energy Technology Data Exchange (ETDEWEB)

    Teraoka, Y.; Sato, M.; Ijichi, S. [Faculty of Agriculture, Kagoshima Univ., Kagoshima (Japan)

    2012-11-01

    Although fossil fuel has been still important energy source in Japan, business managers who examine to sift energy source from oil to bio-fuels would increase for reducing CO{sub 2} emission and high energy cost. It would be quite reasonable choice for Japanese people to use woody biomass for energy sources but woody biomass fuel market hasn't been expanded. One of the reasons is that the Japanese timber production, processing and distribution sectors haven't considered the wood fuel production as by-product. Therefore, this study investigated a potential wood chip boiler demand in south-west Japan through a questionnaire survey for industrial sectors. Second aim is to explain the importance of management information such as a quantity of chip fuel production or distribution and a moisture content of chips from the example cases of installed chip boiler facilities. Expected facilities that would introduce a chip boiler are a hotel, a large hospital, a liquor factory and an aquaculture pool. There will be an annual wood chip fuel demand of 0.756 million green-ton (6.0 PJ) in Kagoshima Prefecture. Problems in more chip boilers introduction are a stable fuel supply and fuel moisture control in addition to the reduction of an initial and operational running cost.

  4. Characterisation of capacitively coupled HV/HR-CMOS sensor chips for the CLIC vertex detector

    Science.gov (United States)

    Kremastiotis, I.

    2017-12-01

    The capacitive coupling between an active sensor and a readout ASIC has been considered in the framework of the CLIC vertex detector study. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is a High-Voltage CMOS sensor chip produced in a commercial 180 nm HV-CMOS process for this purpose. The sensor was designed to be connected to the CLICpix2 readout chip. It therefore matches the dimensions of the readout chip, featuring a matrix of 128×128 square pixels with 25μm pitch. The sensor chip has been produced with the standard value for the substrate resistivity (~20 Ωcm) and it has been characterised in standalone testing mode, before receiving and testing capacitively coupled assemblies. The standalone measurement results show a rise time of ~20 ns for a power consumption of 5μW/pixel. Production of the C3PD HV-CMOS sensor chip with higher substrate resistivity wafers (~20, 80, 200 and 1000 Ωcm) is foreseen. The expected benefits of the higher substrate resistivity will be studied using future assemblies with the readout chip.

  5. A simple clockless Network-on-Chip for a commercial audio DSP chip

    DEFF Research Database (Denmark)

    Stensgaard, Mikkel Bystrup; Bjerregaard, Tobias; Sparsø, Jens

    2006-01-01

    We design a very small, packet-switched, clockless Network-on-Chip (NoC) as a replacement for the existing crossbar-based communication infrastructure in a commercial audio DSP chip. Both solutions are laid out in a 0.18 um process, and compared in terms of area, power consumption and routing...... to the existing crossbar, it allows all blocks to communicate. The total wire length is decreased by 22% which eases the layout process and makes the design less prone to routing congestion. Not least, the communicating blocks are decoupled by means of the NoC, providing a Globally-Asynchronous, Locally...

  6. Experiment list: SRX319556 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ype=mouse embryonic stem cells || genotype/variation=expressing Flag-bio tagged Dax1 || chip beads=Dynabeads... MyOne Streptavidin T1 || chip beads vendor=Invitrogen http://dbarchive.bioscienc

  7. Experiment list: SRX319553 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available se embryonic stem cells || genotype/variation=expressing Flag-bio tagged Tip60 || chip beads=Dynabeads MyOne... Streptavidin T1 || chip beads vendor=Invitrogen http://dbarchive.biosciencedbc.j

  8. Experiment list: SRX319555 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ype=mouse embryonic stem cells || genotype/variation=expressing Flag-bio tagged Dax1 || chip beads=Dynabeads... MyOne Streptavidin T1 || chip beads vendor=Invitrogen http://dbarchive.bioscienc

  9. Experiment list: SRX319551 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available use embryonic stem cells || genotype/variation=expressing Flag-bio tagged Dmap1 || chip beads=Dynabeads MyOn...e Streptavidin T1 || chip beads vendor=Invitrogen http://dbarchive.biosciencedbc.

  10. Design and Development of a Portable Metal Chip Baler using A System Design Approach

    Directory of Open Access Journals (Sweden)

    Hassan Mohd Fahrul

    2017-01-01

    Full Text Available A large amount of metal chips at workplace will result in untidy and unsafe condition thus measurements of safety are needed in some industries, where the metal chips will be collected and put into a container until the volume is sufficient to be recycled. Due to that reason, the metal chips require a lot of spaces for storage before going to recycle. In this study, a portable metal chip baler as a device for compacting those metal chips is presented based on a system approach of engineering design. Basically, the system design evolves through four phases of development that are started from conceptual design, preliminary system design, detail design and development to system test and evaluation. The portable metal chip baler uses current technology such as pneumatic cylinder to compress the metal chips so that the system capable to operate efficiently. The output from this system is the metal chips are compacted into a block shape and a working prototype was developed to prove the concept of the system. As a summary, the conceptual design of portable metal chip baler was proven and was presented using the philosophy of the systems design approach. This tool may assists workers especially in the Small-Medium Enterprise (SME manufacturing industries, school or universities’ workshops for managing metal chips easily and systematically.

  11. A Comparative Study of Wireless Sensor Networks and Their Routing Protocols

    Directory of Open Access Journals (Sweden)

    Subhajit Pal

    2010-11-01

    Full Text Available Recent developments in the area of micro-sensor devices have accelerated advances in the sensor networks field leading to many new protocols specifically designed for wireless sensor networks (WSNs. Wireless sensor networks with hundreds to thousands of sensor nodes can gather information from an unattended location and transmit the gathered data to a particular user, depending on the application. These sensor nodes have some constraints due to their limited energy, storage capacity and computing power. Data are routed from one node to other using different routing protocols. There are a number of routing protocols for wireless sensor networks. In this review article, we discuss the architecture of wireless sensor networks. Further, we categorize the routing protocols according to some key factors and summarize their mode of operation. Finally, we provide a comparative study on these various protocols.

  12. Wood harvesting as chunkwood chips and multi-stage chipping; Puun korjuu palahakkeena ja monivaiheinen lastuaminen

    Energy Technology Data Exchange (ETDEWEB)

    Kaipainen, H; Seppaenen, V

    1997-12-31

    The task for the year 1995 was to define the preliminary results of the previous years, to measure the productivity of a harvester, designed for production of chunkwood, and the properties of the chunks. The costs of the PALAPUU method from the felling site to pulpwood chips were to be examined on this basis. Because the prototype of the harvester was not yet available for field tests, the costs were partially calculated on the basis of previous measurements, completed by productivity data obtained from the time-consumption measurements of a multi-tree harvester, applied with minor alteration for this purpose. According to the calculations the PALAPUU method cannot compete with partial-tree or shortwood methods. The profitability of the method could be improved by adding the transportation density and the productivity of the harvester. It is also possible to procure timber to the mill as partial-trees and to chunk it while feeding it into the drum. Chipping tests were made using the steel-frame-chipper owned by VTT Construction Technology. The blade construction of the chipper was changed so, that it was possible to adjust the cutting thickness of the chips to 4 mm, while in the previous mill-tests it had been 6 mm. The chips were used for cooking tests in the Department of Chemistry of the University of Jyvaeskylae. The results showed that the thinner chips were cooked further under the same cooking conditions. By using the chunkwood method it is possible to harvest 10-70 more biomass for the mills, than it is possible in the pulpwood harvesting

  13. Wood harvesting as chunkwood chips and multi-stage chipping; Puun korjuu palahakkeena ja monivaiheinen lastuaminen

    Energy Technology Data Exchange (ETDEWEB)

    Kaipainen, H.; Seppaenen, V.

    1996-12-31

    The task for the year 1995 was to define the preliminary results of the previous years, to measure the productivity of a harvester, designed for production of chunkwood, and the properties of the chunks. The costs of the PALAPUU method from the felling site to pulpwood chips were to be examined on this basis. Because the prototype of the harvester was not yet available for field tests, the costs were partially calculated on the basis of previous measurements, completed by productivity data obtained from the time-consumption measurements of a multi-tree harvester, applied with minor alteration for this purpose. According to the calculations the PALAPUU method cannot compete with partial-tree or shortwood methods. The profitability of the method could be improved by adding the transportation density and the productivity of the harvester. It is also possible to procure timber to the mill as partial-trees and to chunk it while feeding it into the drum. Chipping tests were made using the steel-frame-chipper owned by VTT Construction Technology. The blade construction of the chipper was changed so, that it was possible to adjust the cutting thickness of the chips to 4 mm, while in the previous mill-tests it had been 6 mm. The chips were used for cooking tests in the Department of Chemistry of the University of Jyvaeskylae. The results showed that the thinner chips were cooked further under the same cooking conditions. By using the chunkwood method it is possible to harvest 10-70 more biomass for the mills, than it is possible in the pulpwood harvesting

  14. Comparison of a Ring On-Chip Network and a Code-Division Multiple-Access On-Chip Network

    Directory of Open Access Journals (Sweden)

    Xin Wang

    2007-01-01

    Full Text Available Two network-on-chip (NoC designs are examined and compared in this paper. One design applies a bidirectional ring connection scheme, while the other design applies a code-division multiple-access (CDMA connection scheme. Both of the designs apply globally asynchronous locally synchronous (GALS scheme in order to deal with the issue of transferring data in a multiple-clock-domain environment of an on-chip system. The two NoC designs are compared with each other by their network structures, data transfer principles, network node structures, and their asynchronous designs. Both the synchronous and the asynchronous designs of the two on-chip networks are realized using a hardware-description language (HDL in order to make the entire designs suit the commonly used synchronous design tools and flow. The performance estimation and comparison of the two NoC designs which are based on the HDL realizations are addressed. By comparing the two NoC designs, the advantages and disadvantages of applying direct connection and CDMA connection schemes in an on-chip communication network are discussed.

  15. Experiment list: SRX319550 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available e embryonic stem cells || genotype/variation=expressing Flag-bio tagged Myc || chip beads=Dynabeads MyOne Streptavidin T1 || chip bea...ds vendor=Invitrogen http://dbarchive.biosciencedbc.jp/k

  16. Nitrogen Immobilization in Plant Growth Substrates: Clean Chip Residual, Pine Bark, and Peatmoss

    Directory of Open Access Journals (Sweden)

    Cheryl R. Boyer

    2012-01-01

    Full Text Available Rising costs of potting substrates have caused horticultural growers to search for alternative, lower-cost materials. Objectives of this study were to determine the extent of nitrogen immobilization and microbial respiration in a high wood-fiber content substrate, clean chip residual. Microbial activity and nitrogen availability of two screen sizes (0.95 cm and 0.48 cm of clean chip residual were compared to control treatments of pine bark and peatmoss in a 60-day incubation experiment. Four rates (0, 1, 2, or 3 mg of supplemental nitrogen were assessed. Peatmoss displayed little microbial respiration over the course of the study, regardless of nitrogen rate; followed by pine bark, 0.95 cm clean chip residual, and 0.48 cm clean chip residual. Respiration increased with increasing nitrogen. Total inorganic nitrogen (plant available nitrogen was greatest with peatmoss; inorganic nitrogen in other treatments were similar at the 0, 1, and 2 mg supplemental nitrogen rates, while an increase occurred with the highest rate (3 mg. Clean chip residual and pine bark were similar in available nitrogen compared to peatmoss. This study suggests that nitrogen immobilization in substrates composed of clean chip residual is similar to pine bark and can be treated with similar fertilizer amendments during nursery production.

  17. Implementing the GBT data transmission protocol in FPGAs

    CERN Document Server

    Baron, S; Marin, F; Moreira, P; Soos, C

    2009-01-01

    The GBT chip [1] is a radiation tolerant ASIC that can be used to implement bidirectional multipurpose 4.8Gb/s optical links for high-energy physics experiments. It will be proposed to the LHC experiments for combined transmission of physics data, trigger, timing, fast and slow control and monitoring. Although radiation hardness is required on detectors, it is not necessary for the electronics located in the counting rooms, where the GBT functionality can be realized using Commercial Off-The-Shelf (COTS) components. This paper describes efficient physical implementation of the GBT protocol achieved for FPGA devices on Altera and Xilinx devices with source codes developed in Verilog and VHDL. The current platforms are based on Altera StratixIIGX and Xilinx Virtex5.

  18. A fast template matching method for LED chip Localization

    Directory of Open Access Journals (Sweden)

    Zhong Fuqiang

    2015-01-01

    Full Text Available Efficiency determines the profits of the semiconductor producers. So the producers spare no effort to enhance the efficiency of every procedure. The purpose of the paper is to present a method to shorten the time to locate the LED chips on wafer. The method consists of 3 steps. Firstly, image segmentation and blob analyzation are used to predict the positions of potential chips. Then predict the orientations of potential chips based on their dominant orientations. Finally, according to the positions and orientations predicted above, locate the chips precisely based on gradient orientation features. Experiments show that the algorithm is faster than the traditional method we choose to locate the LED chips. Besides, even the orientations of the chips on wafer are of big deviation to the orientation of the template, the efficiency of this method won't be affected.

  19. Experiment list: SRX180159 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available sd || cell type=hemogenic endothelium || chip antibody=CEBPb || chip antibody vendor=santa cruz biotechnol...ogy http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/eachData/bw/SRX180159.bw http://

  20. Experiment list: SRX112178 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available line=OS25 ES cells || chip antibody=8WG16 (MMS-126R, Covance) || chip antibody manufacturer=Covance || chromatin=Fixed || beads...=Magnetic beads http://dbarchive.biosciencedbc.jp/kyushu-u/mm

  1. Tunable on chip optofluidic laser

    DEFF Research Database (Denmark)

    Bakal, Avraham; Vannahme, Christoph; Kristensen, Anders

    2016-01-01

    On chip tunable laser is demonstrated by realizing a microfluidic droplet array. The periodicity is controlled by the pressure applied to two separate inlets, allowing to tune the lasing frequency over a broad spectral range.......On chip tunable laser is demonstrated by realizing a microfluidic droplet array. The periodicity is controlled by the pressure applied to two separate inlets, allowing to tune the lasing frequency over a broad spectral range....

  2. Wood chip production technology and costs for fuel in Namibia

    Energy Technology Data Exchange (ETDEWEB)

    Leinonen, A.

    2007-12-15

    This work has been done in the project where the main target is to evaluate the technology and economy to use bush biomass for power production in Namibia. The project has been financed by the Ministry for Foreign Affairs of Finland and the Ministry of Agriculture, Water and Forestry of the Republic of Namibia. The target of this study is to calculate the production costs of bush chips at the power plant using the current production technology and to look possibilities to develop production technology in order to mechanize production technology and to decrease the production costs. The wood production costs are used in feasibility studies, in which the technology and economy of utilization of wood chips for power generation in 5, 10 and 20 MW electric power plants and for power generation in Van Eck coal fired power plant in Windhoek are evaluated. Field tests were made at Cheetah Conservation Farm (CCF) in Otjiwarongo region. CCF is producing wood chips for briquette factory in Otjiwarongo. In the field tests it has been gathered information about this CCF semi-mechanized wood chip production technology. Also new machines for bush biomass chip production have been tested. A new mechanized production chain has been designed on the basis of this information. The production costs for the CCF semi-mechanized and the new production chain have been calculated. The target in the moisture content to produce wood chips for energy is 20 w-%. In the semi-mechanized wood chip production chain the work is done partly manually, and the supply chain is organized into crews of 4.8 men. The production chain consists of manual felling and compiling, drying, chipping with mobile chipper and manual feeding and road transport by a tractor with two trailers. The CCF production chain works well. The chipping and road transport productivity in the semimechanized production chain is low. New production machines, such as chainsaw, brush cutter, lawn mover type cutter, rotator saw in skid

  3. Neural Cell Chip Based Electrochemical Detection of Nanotoxicity.

    Science.gov (United States)

    Kafi, Md Abdul; Cho, Hyeon-Yeol; Choi, Jeong Woo

    2015-07-02

    Development of a rapid, sensitive and cost-effective method for toxicity assessment of commonly used nanoparticles is urgently needed for the sustainable development of nanotechnology. A neural cell with high sensitivity and conductivity has become a potential candidate for a cell chip to investigate toxicity of environmental influences. A neural cell immobilized on a conductive surface has become a potential tool for the assessment of nanotoxicity based on electrochemical methods. The effective electrochemical monitoring largely depends on the adequate attachment of a neural cell on the chip surfaces. Recently, establishment of integrin receptor specific ligand molecules arginine-glycine-aspartic acid (RGD) or its several modifications RGD-Multi Armed Peptide terminated with cysteine (RGD-MAP-C), C(RGD)₄ ensure farm attachment of neural cell on the electrode surfaces either in their two dimensional (dot) or three dimensional (rod or pillar) like nano-scale arrangement. A three dimensional RGD modified electrode surface has been proven to be more suitable for cell adhesion, proliferation, differentiation as well as electrochemical measurement. This review discusses fabrication as well as electrochemical measurements of neural cell chip with particular emphasis on their use for nanotoxicity assessments sequentially since inception to date. Successful monitoring of quantum dot (QD), graphene oxide (GO) and cosmetic compound toxicity using the newly developed neural cell chip were discussed here as a case study. This review recommended that a neural cell chip established on a nanostructured ligand modified conductive surface can be a potential tool for the toxicity assessments of newly developed nanomaterials prior to their use on biology or biomedical technologies.

  4. Neural Cell Chip Based Electrochemical Detection of Nanotoxicity

    Directory of Open Access Journals (Sweden)

    Md. Abdul Kafi

    2015-07-01

    Full Text Available Development of a rapid, sensitive and cost-effective method for toxicity assessment of commonly used nanoparticles is urgently needed for the sustainable development of nanotechnology. A neural cell with high sensitivity and conductivity has become a potential candidate for a cell chip to investigate toxicity of environmental influences. A neural cell immobilized on a conductive surface has become a potential tool for the assessment of nanotoxicity based on electrochemical methods. The effective electrochemical monitoring largely depends on the adequate attachment of a neural cell on the chip surfaces. Recently, establishment of integrin receptor specific ligand molecules arginine-glycine-aspartic acid (RGD or its several modifications RGD-Multi Armed Peptide terminated with cysteine (RGD-MAP-C, C(RGD4 ensure farm attachment of neural cell on the electrode surfaces either in their two dimensional (dot or three dimensional (rod or pillar like nano-scale arrangement. A three dimensional RGD modified electrode surface has been proven to be more suitable for cell adhesion, proliferation, differentiation as well as electrochemical measurement. This review discusses fabrication as well as electrochemical measurements of neural cell chip with particular emphasis on their use for nanotoxicity assessments sequentially since inception to date. Successful monitoring of quantum dot (QD, graphene oxide (GO and cosmetic compound toxicity using the newly developed neural cell chip were discussed here as a case study. This review recommended that a neural cell chip established on a nanostructured ligand modified conductive surface can be a potential tool for the toxicity assessments of newly developed nanomaterials prior to their use on biology or biomedical technologies.

  5. Experiment list: SRX185907 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Homo sapiens; ChIP-Seq source_name=MCF-7 breast adenocarcinoma cells, control, FOXM1 ChIP || cell_line=MCF-...7 || cell_type=ER-positive breast adenocarcinoma cells || treatment=DMSO || chip_

  6. Experiment list: SRX319552 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available embryonic stem cells || genotype/variation=expressing Flag-bio tagged E2F4 || chip beads=Dynabeads MyOne Streptavidin T1 || chip bea...ds vendor=Invitrogen http://dbarchive.biosciencedbc.jp/k

  7. Experiment list: SRX112184 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available line=OS25 ES cells || chip antibody=CTD4H8 (MMS-128P, Covance) || chip antibody manufacturer=Covance || chromatin=Fixed || beads...=Sepharose beads http://dbarchive.biosciencedbc.jp/kyushu-u/m

  8. Experiment list: SRX367328 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available nology) || sirna transfection=siCTL http://dbarchive.bio...=HEK293T cell || cell line=Human Embryonic Kidney 293 cells || chip antibody=CDK9 || chip antibody details=2316S (Cell Signaling Tech

  9. Experiment list: SRX543048 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available nology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/ea...CID.adh murine thymic lymphoma || development stage=DN3 || chip antibody=rabbit anti-Miz-1 || chip antibody vendor=Santa Cruz Biotech

  10. On-chip plasmon-induced transparency based on plasmonic coupled nanocavities.

    Science.gov (United States)

    Zhu, Yu; Hu, Xiaoyong; Yang, Hong; Gong, Qihuang

    2014-01-17

    On-chip plasmon-induced transparency offers the possibility of realization of ultrahigh-speed information processing chips. Unfortunately, little experimental progress has been made to date because it is difficult to obtain on-chip plasmon-induced transparency using only a single meta-molecule in plasmonic circuits. Here, we report a simple and efficient strategy to realize on-chip plasmon-induced transparency in a nanoscale U-shaped plasmonic waveguide side-coupled nanocavity pair. High tunability in the transparency window is achieved by covering the pair with different organic polymer layers. It is possible to realize ultrafast all-optical tunability based on pump light-induced refractive index change of a graphene cover layer. Compared with previous reports, the overall feature size of the plasmonic nanostructure is reduced by more than three orders of magnitude, while ultrahigh tunability of the transparency window is maintained. This work also provides a superior platform for the study of the various physical effects and phenomena of nonlinear optics and quantum optics.

  11. Design of Networks-on-Chip for Real-Time Multi-Processor Systems-on-Chip

    DEFF Research Database (Denmark)

    Sparsø, Jens

    2012-01-01

    This paper addresses the design of networks-on-chips for use in multi-processor systems-on-chips - the hardware platforms used in embedded systems. These platforms typically have to guarantee real-time properties, and as the network is a shared resource, it has to provide service guarantees...... (bandwidth and/or latency) to different communication flows. The paper reviews some past work in this field and the lessons learned, and the paper discusses ongoing research conducted as part of the project "Time-predictable Multi-Core Architecture for Embedded Systems" (T-CREST), supported by the European...

  12. CMOS Image Sensors: Electronic Camera On A Chip

    Science.gov (United States)

    Fossum, E. R.

    1995-01-01

    Recent advancements in CMOS image sensor technology are reviewed, including both passive pixel sensors and active pixel sensors. On- chip analog to digital converters and on-chip timing and control circuits permit realization of an electronic camera-on-a-chip. Highly miniaturized imaging systems based on CMOS image sensor technology are emerging as a competitor to charge-coupled devices for low cost uses.

  13. X-CHIP: an integrated platform for high-throughput protein crystallization and on-the-chip X-ray diffraction data collection

    International Nuclear Information System (INIS)

    Kisselman, Gera; Qiu, Wei; Romanov, Vladimir; Thompson, Christine M.; Lam, Robert; Battaile, Kevin P.; Pai, Emil F.; Chirgadze, Nickolay Y.

    2011-01-01

    The X-CHIP (X-ray Crystallography High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The X-CHIP (X-ray Crystallization High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The system has been designed for crystallization condition screening, visual crystal inspection, initial X-ray screening and data collection in a high-throughput fashion. X-ray diffraction data acquisition can be performed directly on-the-chip at room temperature using an in situ approach. The capabilities of the chip eliminate the necessity for manual crystal handling and cryoprotection of crystal samples, while allowing data collection from multiple crystals in the same drop. This technology would be especially beneficial for projects with large volumes of data, such as protein-complex studies and fragment-based screening. The platform employs hydrophilic and hydrophobic concentric ring surfaces on a miniature plate transparent to visible light and X-rays to create a well defined and stable microbatch crystallization environment. The results of crystallization and data-collection experiments demonstrate that high-quality well diffracting crystals can be grown and high-resolution diffraction data sets can be collected using this technology. Furthermore, the quality of a single-wavelength anomalous dispersion data set collected with the X-CHIP at room temperature was sufficient to generate interpretable electron-density maps. This technology is highly resource-efficient owing to the use of nanolitre-scale drop volumes. It does not require any modification for most in-house and synchrotron beamline systems and offers

  14. X-CHIP: an integrated platform for high-throughput protein crystallization and on-the-chip X-ray diffraction data collection

    Energy Technology Data Exchange (ETDEWEB)

    Kisselman, Gera; Qiu, Wei; Romanov, Vladimir; Thompson, Christine M.; Lam, Robert [Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2C4 (Canada); Battaile, Kevin P. [Argonne National Laboratory, Argonne, Illinois 60439 (United States); Pai, Emil F.; Chirgadze, Nickolay Y., E-mail: nchirgad@uhnresearch.ca [Ontario Cancer Institute, Princess Margaret Hospital, University Health Network, Toronto, Ontario M5G 2C4 (Canada); University of Toronto, Toronto, Ontario M5S 1A8 (Canada)

    2011-06-01

    The X-CHIP (X-ray Crystallography High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The X-CHIP (X-ray Crystallization High-throughput Integrated Platform) is a novel microchip that has been developed to combine multiple steps of the crystallographic pipeline from crystallization to diffraction data collection on a single device to streamline the entire process. The system has been designed for crystallization condition screening, visual crystal inspection, initial X-ray screening and data collection in a high-throughput fashion. X-ray diffraction data acquisition can be performed directly on-the-chip at room temperature using an in situ approach. The capabilities of the chip eliminate the necessity for manual crystal handling and cryoprotection of crystal samples, while allowing data collection from multiple crystals in the same drop. This technology would be especially beneficial for projects with large volumes of data, such as protein-complex studies and fragment-based screening. The platform employs hydrophilic and hydrophobic concentric ring surfaces on a miniature plate transparent to visible light and X-rays to create a well defined and stable microbatch crystallization environment. The results of crystallization and data-collection experiments demonstrate that high-quality well diffracting crystals can be grown and high-resolution diffraction data sets can be collected using this technology. Furthermore, the quality of a single-wavelength anomalous dispersion data set collected with the X-CHIP at room temperature was sufficient to generate interpretable electron-density maps. This technology is highly resource-efficient owing to the use of nanolitre-scale drop volumes. It does not require any modification for most in-house and synchrotron beamline systems and offers

  15. Experiment list: SRX185915 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available mo sapiens; ChIP-Seq source_name=MCF-7 breast adenocarcinoma cells, control, FOXM1 ChIP || cell_line=MCF-7 |...| cell_type=ER-positive breast adenocarcinoma cells || treatment=DMSO || chip_tar

  16. Experiment list: SRX185909 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available omo sapiens; ChIP-Seq source_name=MCF-7 breast adenocarcinoma cells, control, FOXM1 ChIP || cell_line=MCF-7 ...|| cell_type=ER-positive breast adenocarcinoma cells || treatment=DMSO || chip_ta

  17. Experiment list: SRX185917 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available omo sapiens; ChIP-Seq source_name=MCF-7 breast adenocarcinoma cells, control, FOXM1 ChIP || cell_line=MCF-7 ...|| cell_type=ER-positive breast adenocarcinoma cells || treatment=DMSO || chip_ta

  18. Experiment list: SRX112179 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available =OS25 ES cells || chip antibody=H5 (MMS-129R, Covance) || chip antibody manufacturer=Covance || chromatin=Fixed || beads=Magnetic bea...ds http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/eachDa

  19. Experiment list: SRX367330 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available nology) || sirna transfection=siBrd4 http://dbarchive.bi...=HEK293T cell || cell line=Human Embryonic Kidney 293 cells || chip antibody=CDK9 || chip antibody details=2316S (Cell Signaling Tech

  20. Design of a passive UHF RFID tag for the ISO18000-6C protocol

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yao; Wen Guangjun; Mao Wei; He Yanli; Zhu Xueyong, E-mail: wangyao220597@yahoo.com.cn [RFIC Laboratory CICS, School of Communication and Information Engineering, University of Electronic Science and Technology of China, Chengdu 611731 (China)

    2011-05-15

    This paper presents a new fully integrated wide-range UHF passive RFID tag chip design that is compatible with the ISO18000-6C protocol. In order to reduce the die area, an ultra-low power CMOS voltage regulator without resistors and an area-efficient amplitude shift keying demodulator with a novel adaptive average generator are both adopted. A low power clock generator is designed to guarantee the accuracy of the clock under {+-}4%. As the clock gating technology is employed to reduce the power consumption of the baseband processor, the total power consumption of the tag is about 14 {mu}W with a sensitivity of -9.5 dBm. The detection distance can reach about 5 m under 4 W effective isotropic radiated power. The whole tag is fabricated in TSMC 0.18 {mu}m CMOS technology and the chip size is 880 x 880 {mu}m{sup 2}. (semiconductor integrated circuits)

  1. Design of a passive UHF RFID tag for the ISO18000-6C protocol

    International Nuclear Information System (INIS)

    Wang Yao; Wen Guangjun; Mao Wei; He Yanli; Zhu Xueyong

    2011-01-01

    This paper presents a new fully integrated wide-range UHF passive RFID tag chip design that is compatible with the ISO18000-6C protocol. In order to reduce the die area, an ultra-low power CMOS voltage regulator without resistors and an area-efficient amplitude shift keying demodulator with a novel adaptive average generator are both adopted. A low power clock generator is designed to guarantee the accuracy of the clock under ±4%. As the clock gating technology is employed to reduce the power consumption of the baseband processor, the total power consumption of the tag is about 14 μW with a sensitivity of -9.5 dBm. The detection distance can reach about 5 m under 4 W effective isotropic radiated power. The whole tag is fabricated in TSMC 0.18 μm CMOS technology and the chip size is 880 x 880 μm 2 . (semiconductor integrated circuits)

  2. Fate of clinical research studies after ethical approval--follow-up of study protocols until publication.

    Directory of Open Access Journals (Sweden)

    Anette Blümle

    Full Text Available Many clinical studies are ultimately not fully published in peer-reviewed journals. Underreporting of clinical research is wasteful and can result in biased estimates of treatment effect or harm, leading to recommendations that are inappropriate or even dangerous.We assembled a cohort of clinical studies approved 2000-2002 by the Research Ethics Committee of the University of Freiburg, Germany. Published full articles were searched in electronic databases and investigators contacted. Data on study characteristics were extracted from protocols and corresponding publications. We characterized the cohort, quantified its publication outcome and compared protocols and publications for selected aspects.Of 917 approved studies, 807 were started and 110 were not, either locally or as a whole. Of the started studies, 576 (71% were completed according to protocol, 128 (16% discontinued and 42 (5% are still ongoing; for 61 (8% there was no information about their course. We identified 782 full publications corresponding to 419 of the 807 initiated studies; the publication proportion was 52% (95% CI: 0.48-0.55. Study design was not significantly associated with subsequent publication. Multicentre status, international collaboration, large sample size and commercial or non-commercial funding were positively associated with subsequent publication. Commercial funding was mentioned in 203 (48% protocols and in 205 (49% of the publications. In most published studies (339; 81% this information corresponded between protocol and publication. Most studies were published in English (367; 88%; some in German (25; 6% or both languages (27; 6%. The local investigators were listed as (co-authors in the publications corresponding to 259 (62% studies.Half of the clinical research conducted at a large German university medical centre remains unpublished; future research is built on an incomplete database. Research resources are likely wasted as neither health care

  3. The recycling through melting machining chips: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Luiz A.T.; Rossi, Jesualdo L., E-mail: luiz.atp@uol.com.br, E-mail: jelrossi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro de Ciência e Tecnologia de Materiais

    2017-07-01

    PWR (Pressurized Water Reactor) reactors employ as nuclear fuel UO{sub 2} pellets packed in zirconium alloy tubes, called cladding. In the manufacture of the tubes, machining chips are generated which cannot be discarded, since the recycling of this material is strategic in terms of nuclear technology, legislation, economics and the environment. These nuclear alloys are very expensive and are not produced in Brazil and are imported for the manufacture of nuclear fuel. In this work, it will examined methods not yet studied to recycle Zircaloy chips using electron beam furnace in order to obtain ingots. In addition, it is intended to carry out the melting of new Zircaloy alloys, from the melting of zirconium sponge obtained in IPEN and imported and Zircaloy bars. The mechanical properties and the present phases of the material should be determined, as well as, the characterization of the microstructures by optical microscopy. This work, therefore, aims at the creation of a new line of research where methods will be approached to recycle the Zircaloy chips and to reduce in 30 times the volume by means of melting the enormous amount of material stored in the form of machining chips, being able to do others components for nuclear or chemical industry use, as well as conducting basic development research. (author)

  4. A primary battery-on-a-chip using monolayer graphene

    Science.gov (United States)

    Iost, Rodrigo M.; Crespilho, Frank N.; Kern, Klaus; Balasubramanian, Kannan

    2016-07-01

    We present here a bottom-up approach for realizing on-chip on-demand batteries starting out with chemical vapor deposition-grown graphene. Single graphene monolayers contacted by electrode lines on a silicon chip serve as electrodes. The anode and cathode are realized by electrodeposition of zinc and copper respectively onto graphene, leading to the realization of a miniature graphene-based Daniell cell on a chip. The electrolyte is housed partly in a gel and partly in liquid form in an on-chip enclosure molded using a 3d printer or made out of poly(dimethylsiloxane). The realized batteries provide a stable voltage (∼1.1 V) for many hours and exhibit capacities as high as 15 μAh, providing enough power to operate a pocket calculator. The realized batteries show promise for deployment as on-chip power sources for autonomous systems in lab-on-a-chip or biomedical applications.

  5. Experiment list: SRX112176 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available e=OS25 ES cells || chip antibody=CTD4H8 (MMS-128P, Covance) || chip antibody manufacturer=Covance || chromatin=Fixed || beads...=Magnetic beads http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/e

  6. Developing an Integrated Design Strategy for Chip Layout Optimization

    NARCIS (Netherlands)

    Wits, Wessel Willems; Jauregui Becker, Juan Manuel; van Vliet, Frank Edward; te Riele, G.J.

    2011-01-01

    This paper presents an integrated design strategy for chip layout optimization. The strategy couples both electric and thermal aspects during the conceptual design phase to improve chip performances; thermal management being one of the major topics. The layout of the chip circuitry is optimized

  7. Alpha radiation detection using silicon memory chips - preliminary studies

    International Nuclear Information System (INIS)

    Pace, R.; Paix, D.; Haskard, M.

    1993-01-01

    Alpha radiation dosage is an important occupational health factor in the mining of uranium and mineral sands. Alpha radiation induced errors in the data of silicon based memory chips provide the foundation for a new type of sensor, with the potential for affordable and prompt measurement of personal alpha doses. With particular reference to Dynamic Random Access Memories (DRAM) this paper introduces the operating principle of a memory based radiation sensor, which is the error mechanism in silicon integrated circuits. 14 refs., 3 figs

  8. Integrated lasers for polymer Lab-on-a-Chip systems

    DEFF Research Database (Denmark)

    Mappes, Timo; Vannahme, Christoph; Grosmann, Tobias

    2012-01-01

    We develop optical Lab-on-a-Chips on different platforms for marker-based and label-free biophotonic sensor applications. Our chips are based on polymers and fabricated by mass production technologies to integrate microfluidic channels, optical waveguides and miniaturized lasers.......We develop optical Lab-on-a-Chips on different platforms for marker-based and label-free biophotonic sensor applications. Our chips are based on polymers and fabricated by mass production technologies to integrate microfluidic channels, optical waveguides and miniaturized lasers....

  9. Wood chips procurement and research project at the Mikkeli region; Puuhakkeen hankinta- ja tutkimusprojekti Mikkelin seudulla

    Energy Technology Data Exchange (ETDEWEB)

    Saksa, T [Finnish Forest Research Inst., Suonenjoki (Finland). Suonenjoki Research Station; Auvinen, P [Mikkeli city (Finland). Dept. of Agriculture and Forestry

    1997-12-31

    In 1993-94, a large-scale energywood production chain started as a co-operation project by the Mikkeli city forest office and local forestry societies. In 1995 over 115 000 m{sup 3} (about 85 000 MWh of energy) of wood chips were delivered to Pursiala heat and power plant in Mikkeli. About 75 % of these chips was forest processed chips. About 70 % of the forest processed chips was whole tree chips from improvement cuttings of young forest stands and the rest was logging waste chips from regeneration cutting areas. The average total delivery costs of forest processed chips after reduction of energywood and other subsidies were approximately 45 FIM/m{sup 3} (60 FIM/MWh) for the whole tree chips and 38 FIM/m{sup 3} (50 FIM/MWh) for logging waste chips. The delivery costs of forest processed chips could meet the target of Bioenergy Research Programme (45 FIM/MWh) only in the most favourable cases. In an average the delivery costs were about 9 FIM/MWh more than the price obtained when sold to the heat and power plant. However the wood chip production created 27 new jobs and the increase of income to the local economy was about 2.2 milj. FIM /year. The local communities got new tax revenue about 3 FIM/MWh. The gain for the forestry was approximated to be 5 - 6 FIM/MWh. The resources of forest processed chips were studied on the basis of stand measurements. According to the study the most remarkable energywood resources were in young thinning stands on Oxalis-Myrtillus and Myrtillus forest site types. On Oxalis-Myrtillus type almost every and on Myrtillus type every second stand included energywood more than 40 m{sup 3}/ha

  10. Wood chips procurement and research project at the Mikkeli region; Puuhakkeen hankinta- ja tutkimusprojekti Mikkelin seudulla

    Energy Technology Data Exchange (ETDEWEB)

    Saksa, T. [Finnish Forest Research Inst., Suonenjoki (Finland). Suonenjoki Research Station; Auvinen, P. [Mikkeli city (Finland). Dept. of Agriculture and Forestry

    1996-12-31

    In 1993-94, a large-scale energywood production chain started as a co-operation project by the Mikkeli city forest office and local forestry societies. In 1995 over 115 000 m{sup 3} (about 85 000 MWh of energy) of wood chips were delivered to Pursiala heat and power plant in Mikkeli. About 75 % of these chips was forest processed chips. About 70 % of the forest processed chips was whole tree chips from improvement cuttings of young forest stands and the rest was logging waste chips from regeneration cutting areas. The average total delivery costs of forest processed chips after reduction of energywood and other subsidies were approximately 45 FIM/m{sup 3} (60 FIM/MWh) for the whole tree chips and 38 FIM/m{sup 3} (50 FIM/MWh) for logging waste chips. The delivery costs of forest processed chips could meet the target of Bioenergy Research Programme (45 FIM/MWh) only in the most favourable cases. In an average the delivery costs were about 9 FIM/MWh more than the price obtained when sold to the heat and power plant. However the wood chip production created 27 new jobs and the increase of income to the local economy was about 2.2 milj. FIM /year. The local communities got new tax revenue about 3 FIM/MWh. The gain for the forestry was approximated to be 5 - 6 FIM/MWh. The resources of forest processed chips were studied on the basis of stand measurements. According to the study the most remarkable energywood resources were in young thinning stands on Oxalis-Myrtillus and Myrtillus forest site types. On Oxalis-Myrtillus type almost every and on Myrtillus type every second stand included energywood more than 40 m{sup 3}/ha

  11. Experiment list: SRX262781 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available _name=NIH3T3_SRF_15 || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=SRF || chip antibody vendor=Santa Cruz Biotec...hnology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/e

  12. Experiment list: SRX262786 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available H3T3_MRTFA_15 || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=MRTF-A || chip antibody vendor=Santa Cruz Biotechno...logy http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/each

  13. Experiment list: SRX262791 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available IH3T3_MRTFB_LAT || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=MRTF-B || chip antibody vendor=Santa Cruz Biotech...nology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/ea

  14. Experiment list: SRX262782 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available echnology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9...ce_name=NIH3T3_SRF_15 || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=SRF || chip antibody vendor=Santa Cruz Biot

  15. Experiment list: SRX262788 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available IH3T3_MRTFA_UO || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=MRTF-A || chip antibody vendor=Santa Cruz Biotechn...ology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/eac

  16. Experiment list: SRX262787 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available IH3T3_MRTFA_LAT || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=MRTF-A || chip antibody vendor=Santa Cruz Biotech...nology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/ea

  17. Experiment list: SRX262780 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available chnology http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/...e_name=NIH3T3_SRF_03 || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=SRF || chip antibody vendor=Santa Cruz Biote

  18. 3D Printing of Organs-On-Chips.

    Science.gov (United States)

    Yi, Hee-Gyeong; Lee, Hyungseok; Cho, Dong-Woo

    2017-01-25

    Organ-on-a-chip engineering aims to create artificial living organs that mimic the complex and physiological responses of real organs, in order to test drugs by precisely manipulating the cells and their microenvironments. To achieve this, the artificial organs should to be microfabricated with an extracellular matrix (ECM) and various types of cells, and should recapitulate morphogenesis, cell differentiation, and functions according to the native organ. A promising strategy is 3D printing, which precisely controls the spatial distribution and layer-by-layer assembly of cells, ECMs, and other biomaterials. Owing to this unique advantage, integration of 3D printing into organ-on-a-chip engineering can facilitate the creation of micro-organs with heterogeneity, a desired 3D cellular arrangement, tissue-specific functions, or even cyclic movement within a microfluidic device. Moreover, fully 3D-printed organs-on-chips more easily incorporate other mechanical and electrical components with the chips, and can be commercialized via automated massive production. Herein, we discuss the recent advances and the potential of 3D cell-printing technology in engineering organs-on-chips, and provides the future perspectives of this technology to establish the highly reliable and useful drug-screening platforms.

  19. Chip-based microtrap arrays for cold polar molecules

    Science.gov (United States)

    Hou, Shunyong; Wei, Bin; Deng, Lianzhong; Yin, Jianping

    2017-12-01

    Compared to the atomic chip, which has been a powerful platform to perform an astonishing range of applications from rapid Bose-Einstein condensate (BEC) production to the atomic clock, the molecular chip is only in its infant stages. Recently a one-dimensional electric lattice was demonstrated to trap polar molecules on a chip. This excellent work opens up the way to building a molecular chip laboratory. Here we propose a two-dimensional (2D) electric lattice on a chip with concise and robust structure, which is formed by arrays of squared gold wires. Arrays of microtraps that originate in the microsize electrodes offer a steep gradient and thus allow for confining both light and heavy polar molecules. Theoretical analysis and numerical calculations are performed using two types of sample molecules, N D3 and SrF, to justify the possibility of our proposal. The height of the minima of the potential wells is about 10 μm above the surface of the chip and can be easily adjusted in a wide range by changing the voltages applied on the electrodes. These microtraps offer intriguing perspectives for investigating cold molecules in periodic potentials, such as quantum computing science, low-dimensional physics, and some other possible applications amenable to magnetic or optical lattice. The 2D adjustable electric lattice is expected to act as a building block for a future gas-phase molecular chip laboratory.

  20. An Energy-Efficient Reconfigurable Circuit Switched Network-on-Chip

    NARCIS (Netherlands)

    Wolkotte, P.T.; Smit, Gerardus Johannes Maria; Rauwerda, G.K.; Smit, L.T.

    Network-on-Chip (NoC) is an energy-efficient on-chip communication architecture for multi-tile System-on-Chip (SoC) architectures. The SoC architecture, including its run-time software, can replace inflexible ASICs for future ambient systems. These ambient systems have to be flexible as well as

  1. Energy Model of Networks-on-Chip and a Bus

    NARCIS (Netherlands)

    Wolkotte, P.T.; Smit, Gerardus Johannes Maria; Kavaldjiev, N.K.; Becker, Jens E.; Becker, Jürgen; Nurmi, J.; Takala, J.; Hamalainen, T.D.

    2005-01-01

    A Network-on-Chip (NoC) is an energy-efficient onchip communication architecture for Multi-Processor Systemon-Chip (MPSoC) architectures. In earlier papers we proposed two Network-on-Chip architectures based on packet-switching and circuit-switching. In this paper we derive an energy model for both

  2. Logistics of in-wood chipping and trucking of chips; Palstahaketuksen logistinen ketju

    Energy Technology Data Exchange (ETDEWEB)

    Nuuja, J [Joensuu Univ. (Finland). Faculty of Forestry; Asikainen, A [Metsaeosaamiskeskus, Joensuu (Finland). Joensuu Science Park

    1997-12-31

    In this study a in wood chipper and truck transport of chips were modelled and studied by discrete-event simulation. The input data, which included stand characteristics and information about transport distances was compiled by GRASS-program. This data based on the inventory done by Forestry Center TAPIO. With the model various transport alternatives were compared and the effect of work condition factors were studied. It was find out, that a long distance transport with interchangeable container truck gives better productivity than a truck with a trailer. This results from shorter loading time for the interchangeable container truck

  3. Logistics of in-wood chipping and trucking of chips; Palstahaketuksen logistinen ketju

    Energy Technology Data Exchange (ETDEWEB)

    Nuuja, J. [Joensuu Univ. (Finland). Faculty of Forestry; Asikainen, A. [Metsaeosaamiskeskus, Joensuu (Finland). Joensuu Science Park

    1996-12-31

    In this study a in wood chipper and truck transport of chips were modelled and studied by discrete-event simulation. The input data, which included stand characteristics and information about transport distances was compiled by GRASS-program. This data based on the inventory done by Forestry Center TAPIO. With the model various transport alternatives were compared and the effect of work condition factors were studied. It was find out, that a long distance transport with interchangeable container truck gives better productivity than a truck with a trailer. This results from shorter loading time for the interchangeable container truck

  4. Measuring the attenuation length of water in the CHIPS-M water Cherenkov detector

    Energy Technology Data Exchange (ETDEWEB)

    Amat, F.; Bizouard, P. [Aix Marseille University Saint-Jerome, 13013 Marseille (France); Bryant, J. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Carroll, T.J.; Rijck, S. De [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Germani, S. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Joyce, T. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Kriesten, B. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Marshak, M.; Meier, J. [School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455 (United States); Nelson, J.K. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Perch, A.J.; Pfützner, M.M. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Salazar, R. [Department of Physics, University of Texas at Austin, Austin, TX 78712 (United States); Thomas, J., E-mail: jennifer.thomas@ucl.ac.uk [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Trokan-Tenorio, J. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Vahle, P. [Department of Physics, College of William & Mary, Williamsburg, VA 23187 (United States); Wade, R. [Avenir Consulting, Abingdon, Oxfordshire (United Kingdom); Wendt, C. [Department of Physics, University of Wisconsin, Madison, WI 53706 (United States); Whitehead, L.H. [Department of Physics and Astronomy, UCL, Gower St, London WC1E 6BT (United Kingdom); and others

    2017-02-01

    The water at the proposed site of the CHIPS water Cherenkov detector has been studied to measure its attenuation length for Cherenkov light as a function of filtering time. A scaled model of the CHIPS detector filled with water from the Wentworth 2W pit, proposed site of the CHIPS deployment, in conjunction with a 3.2 m vertical column filled with this water, was used to study the transmission of 405 nm laser light. Results consistent with attenuation lengths of up to 100 m were observed for this wavelength with filtration and UV sterilization alone.

  5. Experiment list: SRX262797 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 3T3_SAP1_03 || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=SAP-1a || chip antibody vendor=Santa Cruz Biotechnolo...gy http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/eachDa

  6. Experiment list: SRX262799 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available H3T3_SAP1_LAT || cell line=NIH3T3 fibroblasts || genotype=normal || chip antibody=SAP-1a || chip antibody vendor=Santa Cruz Biotechno...logy http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/each

  7. Experiment list: SRX352046 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available SM1232564: CSB M CHIP; Homo sapiens; ChIP-Seq source_name=fibroblast_menadione_CSB-ChIP || cell type=fibroblast || treated with=menad...ione || chip antibody=Mouse monoclonal anti-CSB N Terminus (1B1) http://dbarchive.b

  8. Microneedle Array Interface to CE on Chip

    NARCIS (Netherlands)

    Lüttge, Regina; Gardeniers, Johannes G.E.; Vrouwe, E.X.; van den Berg, Albert; Northrup, M.A.; Jensen, K.F; Harrison, D.J.

    2003-01-01

    This paper presents a microneedle array sampler interfaced to a capillary electrophoresis (CE) glass chip with integrated conductivity detection electrodes. A solution of alkali ions was electrokinetically loaded through the microneedles onto the chip and separation was demonstrated compared to a

  9. Experiment list: SRX144526 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available stein-Barr Virus transformed 11803840,92.5,91.6,38 GSM922971: NRF2 ChIP vehicle treated rep2; Homo sapiens; ...ChIP-Seq source_name=NRF2 ChIP vehicle treated || biomaterial_provider=Coriell; h

  10. Experiment list: SRX151245 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 0: CTCF ChIPSeq; Homo sapiens; ChIP-Seq source_name=BCBL1 pleural effusion lymphoma, CTCF ChIP || cell line=...BCBL1 || cell type=KSHV-infected pleural effusion lymphoma cells || chip antibody=rabbit anti-CTCF || antibo

  11. On-chip Magnetic Separation and Cell Encapsulation in Droplets

    Science.gov (United States)

    Chen, A.; Byvank, T.; Bharde, A.; Miller, B. L.; Chalmers, J. J.; Sooryakumar, R.; Chang, W.-J.; Bashir, R.

    2012-02-01

    The demand for high-throughput single cell assays is gaining importance because of the heterogeneity of many cell suspensions, even after significant initial sorting. These suspensions may display cell-to-cell variability at the gene expression level that could impact single cell functional genomics, cancer, stem-cell research and drug screening. The on-chip monitoring of individual cells in an isolated environment could prevent cross-contamination, provide high recovery yield and ability to study biological traits at a single cell level These advantages of on-chip biological experiments contrast to conventional methods, which require bulk samples that provide only averaged information on cell metabolism. We report on a device that integrates microfluidic technology with a magnetic tweezers array to combine the functionality of separation and encapsulation of objects such as immunomagnetically labeled cells or magnetic beads into pico-liter droplets on the same chip. The ability to control the separation throughput that is independent of the hydrodynamic droplet generation rate allows the encapsulation efficiency to be optimized. The device can potentially be integrated with on-chip labeling and/or bio-detection to become a powerful single-cell analysis device.

  12. Enabling rapid behavioral ecotoxicity studies using an integrated lab-on-a-chip systems

    Science.gov (United States)

    Huang, Yushi; Nugegoda, Dayanthi; Wlodkowic, Donald

    2015-12-01

    Behavioral ecotoxicity tests are gaining an increasing recognition in environmental toxicology. Behavior of sensitive bioindicator species can change rapidly in response to an acute exposure to contaminants and thus has a much higher sensitivity as compared to conventional LC50 mortality tests. Furthermore, behavioral endpoints seems to be very good candidates to develop early-warning biomonitoring systems needed for rapid chemical risk assessment. Behavioral tests are non-invasive, fast, do not harm indicator organisms (behavioural changes are very rapid) and are thus fully compatible with 3R (Replacement - Reduction - Refinement) principle encouraging alternatives to conventional animal testing. These characteristics are essential when designing improved ecotoxicity tests for chemical risk assessment. In this work, we present a pilot development of miniaturized Lab-on-a-Chip (LOC) devices for studying toxin avoidance behaviors of small aquatic crustaceans. As an investigative tool, LOCs represent a new direction that may miniaturize and revolutionize behavioral ecotoxicology. Specifically our innovative microfluidic prototype: (i) enables convening "caging" of specimens for real-time videomicroscopy; (ii) eliminates the evaporative water loss thus providing an opportunity for long-term behavioral studies; (iii) exploits laminar fluid flow under low Reynolds numbers to generate discrete domains and gradients enabling for the first time toxin avoidance studies on small aquatic crustaceans; (iv) integrates off-the-chip mechatronic interfaces and video analysis algorithms for single animal movement analysis. We provide evidence that by merging innovative bioelectronic and biomicrofluidic technologies we can deploy inexpensive and reliable systems for culture, electronic tracking and complex computational analysis of behavior of bioindicator organisms.

  13. Airtight storage of wood chips for use as a fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lamond, W.J.; Graham, R.; Boyd, J.E.L.; Harling, R.; Lowe, J.F.

    1993-11-01

    This study was carried out to see if airtight storage was a possible alternative to drying as a procedure for the successful storage of chipped wood for fuel. Twelve insulated bins, with a capacity of approximately 0.1 m{sup 3} each, were filled with freshly cut Sitka Spruce wood chips. Ten of these bins were sealed immediately after filling and the remaining two left unsealed for the duration of the experiment (12 months). The programme of sampling for gas, moisture content, mycology and bacteriology is described. The results showed that sealed storage reduced the overall dry matter loss in the bins to around 1% per month compared to 2% for the unsealed bins. This compares favourably with losses of around 3% per month which have been reported for open stacks of chips with much lower initial moisture contents than that used in these experiments. There was a slight reduction in the colorific value of oven dried chips between the initial and after storage samples. The moisture content of the chips in all the bins increased over the storage period. The average energy loss was 2.9% per month for sealed and 2.0% per month for unsealed treatment. A typical ecological succession was shown by the chips, commencing with field fungi and terminating with a dominant yeast population. Potential costs for suitable stores vary from Pounds 1.27 per m{sup 3} per year for a plastic covered outdoor stack to Pounds 11.72 per m{sup 3} per year for a vitreous enamel silo. (UK)

  14. Synthesis of on-chip control circuits for mVLSI biochips

    DEFF Research Database (Denmark)

    Potluri, Seetal; Schneider, Alexander Rüdiger; Hørslev-Petersen, Martin

    2017-01-01

    them to laboratory environments. To address this issue, researchers have proposed methods to reduce the number of offchip pressure sources, through integration of on-chip pneumatic control logic circuits fabricated using three-layer monolithic membrane valve technology. Traditionally, mVLSI biochip......-chip control circuit design and (iii) the integration of on-chip control in the placement and routing design tasks. In this paper we present a design methodology for logic synthesis and physical synthesis of mVLSI biochips that use on-chip control. We show how the proposed methodology can be successfully...... applied to generate biochip layouts with integrated on-chip pneumatic control....

  15. Experiment list: SRX150568 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available is=Adenocarcinoma 59265240,72.4,16.4,4779 GSM935489: Harvard ChipSeq HeLa-S3 RPC155 std source_name=HeLa-S3 ...|| biomaterial_provider=ATCC || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipS

  16. Experiment list: SRX150661 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available is=Adenocarcinoma 59396606,71.7,11.1,1200 GSM935582: Harvard ChipSeq HeLa-S3 BRF1 std source_name=HeLa-S3 ||... biomaterial_provider=ATCC || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipSeq

  17. Experiment list: SRX150495 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available is=Adenocarcinoma 62508352,67.6,8.4,1556 GSM935416: Harvard ChipSeq HeLa-S3 ZZZ3 std source_name=HeLa-S3 || ...biomaterial_provider=ATCC || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipSeq

  18. Experiment list: SRX150565 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available =Adenocarcinoma 54953593,74.3,12.2,1703 GSM935486: Harvard ChipSeq HeLa-S3 BDP1 std source_name=HeLa-S3 || b...iomaterial_provider=ATCC || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipSeq |

  19. Performance evaluation of chip seals in Idaho.

    Science.gov (United States)

    2010-08-01

    The intent of this research project is to identify a wide variety of parameters that influence the performance of pavements treated via chip seals within the State of Idaho. Chip sealing is currently one of the most popular methods of maintenance for...

  20. Experiment list: SRX507380 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available + (wildtype) || age of animals=1-5 day old || tissue=Ovaries || chip antibody=anti-HP1 || chip antibody vend...1770: WT anti-HP1- replicate#2; Drosophila melanogaster; ChIP-Seq source_name=WT_WT_anti-HP1 || strain=piwi/

  1. Experiment list: SRX176054 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available nosis=Carcinoma 13338805,91.2,4.9,792 GSM984386: LNCAP AR vehicle; Homo sapiens; ChIP-Seq source_name=prosta...te cancer cells || cell line=LNCaP || chip antibody=AR || chip antibody manufacturer=Abcam || treatment=EtOH vehicle

  2. Experiment list: SRX144525 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available neage=mesoderm|Description=parental cell type to lymphoblastoid cell lines 14487710,85.8,82.8,188 GSM922970: NRF2 ChIP vehicle... treated rep1; Homo sapiens; ChIP-Seq source_name=NRF2 ChIP vehicle treated || biomaterial

  3. Experiment list: SRX144524 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available neage=mesoderm|Description=parental cell type to lymphoblastoid cell lines 4766716,6.2,89.4,0 GSM922969: NRF2 ChIP vehicle... treated pilot; Homo sapiens; ChIP-Seq source_name=NRF2 ChIP vehicle treated || biomaterial_pr

  4. Experiment list: SRX151246 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 11: SMC1 ChIPSeq; Homo sapiens; ChIP-Seq source_name=BCBL1 pleural effusion lymphoma, SMC1 ChIP || cell line...=BCBL1 || cell type=KSHV-infected pleural effusion lymphoma cells || chip antibody=rabbit anti-SMC1 || antib

  5. New generation of single-chip microcomputers focused on cost performance

    Energy Technology Data Exchange (ETDEWEB)

    Akao, Y.; Iwashita, H. (Hitachi, Ltd., Tokyo (Japan))

    1993-06-01

    A single-chip microcomputer which incorporates a CPU (central processing unit), memory, and peripheral functions in one chip has been increasingly applied to various fields as the heart of electronic equipment in terms of its economy, compactness, lightness, and suitability for mass production. In response to a wide variety of needs, a lineup must have substantial breadth with regard to performance, on-chip memory capacity, on-chip peripheral functions, operating voltage, and packaging. In particular, low-voltage high-speed operation, high integration, expanded address space, and improved software productivity, which are required for mobile communication terminals, are the common needs for single-chip microcomputers. In accordance with these needs, Hitachi has been actively developing new products. The present paper introduces Hitachi's lineup of single-chip microcomputers. 10 figs., 1 tab.

  6. Cassava chip (Manihot esculenta Crantz as an energy source for ruminant feeding

    Directory of Open Access Journals (Sweden)

    Metha Wanapat

    2015-12-01

    Full Text Available Cassava (Manihot esculenta Crantz is widely grown in sub-tropical and tropical areas, producing roots as an energy source while the top biomass including leaves and immature stems can be sun-dried and used as cassava hay. Cassava roots can be processed as dried chip or pellet. It is rich in soluble carbohydrate (75 to 85% but low in crude protein (2 to 3%. Its energy value is comparable to corn meal but has a relatively higher rate of rumen degradation. Higher levels of non-protein nitrogen especially urea (1 to 4% can be successfully incorporated in concentrates containing cassava chip as an energy source. Cassava chip can also be processed with urea and other ingredients (tallow, sulfur, raw banana meal, cassava hay, and soybean meal to make products such as cassarea, cassa-ban, and cassaya. Various studies have been conducted in ruminants using cassava chip to replace corn meal in the concentrate mixtures and have revealed satisfactory results in rumen fermentation efficiency and the subsequent production of meat and milk. In addition, it was advantageous when used in combination with rice bran in the concentrate supplement. Practical home-made-concentrate using cassava chip can be easily prepared for use on farms. A recent development has involved enriching protein in cassava chips, yielding yeast fermented cassava chip protein (YEFECAP of up to 47.5% crude protein, which can be used to replace soybean meal. It is therefore, recommended to use cassava chip as an alternative source of energy to corn meal when the price is economical and it is locally available.

  7. Development of a cell microarray chip for detection of circulating tumor cells

    Science.gov (United States)

    Yamamura, S.; Yatsushiro, S.; Abe, K.; Baba, Y.; Kataoka, M.

    2012-03-01

    Detection of circulating tumor cells (CTCs) in the peripheral blood of metastatic cancer patients has clinical significance in earlier diagnosis of metastases. In this study, a novel cell microarray chip for accurate and rapid detection of tumor cells from human leukocytes was developed. The chip with 20,944 microchambers (105 μm diameter and 50 μm depth) was made from polystyrene, and the surface was rendered to hydrophilic by means of reactive-ion etching, which led to the formation of mono-layers of leukocytes on the microchambers. As the model of CTCs detection, we spiked human bronchioalveolar carcinoma (H1650) cells into human T lymphoblastoid leukemia (CEM) cells suspension and detected H1650 cells using the chip. A CEM suspension contained with H1650 cells was dispersed on the chip surface, followed by 10 min standing to allow the cells to settle down into the microchambers. About 30 CEM cells were accommodated in each microchamber, over 600,000 CEM cells in total being on a chip. We could detect 1 H1650 cell per 106 CEM cells on the microarray by staining with fluorescence-conjugated antibody (Anti-Cytokeratin) and cell membrane marker (DiD). Thus, this cell microarray chip has highly potential to be a novel tool of accurate and rapid detection of CTCs.

  8. Experiment list: SRX150586 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available -Barr Virus 33195472,90.4,25.9,15633 GSM935507: Harvard ChipSeq GM12878 NF-YB IgG-mus source_name=GM12878 ||...?PgId=165&q=GM12878 || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipSeq || dat

  9. Experiment list: SRX150496 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available ein-Barr Virus 63040797,85.0,19.7,1435 GSM935417: Harvard ChipSeq GM12878 SPT20 std source_name=GM12878 || b...gId=165&q=GM12878 || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipSeq || datat

  10. Experiment list: SRX150585 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available -Barr Virus 32926476,94.0,12.0,2668 GSM935506: Harvard ChipSeq GM12878 NF-YA IgG-mus source_name=GM12878 || ...PgId=165&q=GM12878 || lab=Harvard || lab description=Struhl - Harvard University || datatype=ChipSeq || data

  11. A Chip for an Implantable Neural Stimulator

    DEFF Research Database (Denmark)

    Gudnason, Gunnar; Bruun, Erik; Haugland, Morten

    2000-01-01

    This paper describes a chip for a multichannel neural stimulator for functional electrical stimulation (FES). The purpose of FES is to restore muscular control in disabled patients. The chip performs all the signal processing required in an implanted neural stimulator. The power and digital data...

  12. Experiment list: SRX153146 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available -Seq source_name=Human breast adenocarcinoma cell-line MCF7 || cell-line=MCF7 || passage=5 || chip antibody=...n=Pleura|Tissue Diagnosis=Adenocarcinoma 60170246,98.4,5.7,16756 GSM946850: MCF7 H3K27ac; Homo sapiens; ChIP

  13. Experiment list: SRX176063 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available =Carcinoma 11279321,95.5,3.6,13985 GSM984395: LNCAP ACH3 vehicle; Homo sapiens; ChIP-Seq source_name=prostat...e cancer cells || cell line=LNCaP || chip antibody=AcH3 || chip antibody manufacturer=Millipore || treatment=EtOH vehicle

  14. Experiment list: SRX176057 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available nosis=Carcinoma 21582823,90.1,7.3,1074 GSM984389: 22RV1 AR vehicle; Homo sapiens; ChIP-Seq source_name=prost...ate cancer cells || cell line=22RV1 || chip antibody=AR || chip antibody manufacturer=Abcam || treatment=EtOH vehicle

  15. Experiment list: SRX144527 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available neage=mesoderm|Description=parental cell type to lymphoblastoid cell lines 8704444,92.1,92.5,9 GSM922972: NRF2 ChIP vehicle... treated rep3; Homo sapiens; ChIP-Seq source_name=NRF2 ChIP vehicle treated || biomaterial_pr

  16. Experiment list: SRX160914 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available M970829: IgG for KSHV LANA; Homo sapiens; ChIP-Seq source_name=BCBL1 pleural effusion lymphoma, IgG ChIP || ...cell line=BCBL1 || cell type=KSHV-infected pleural effusion lymphoma cells || chip antibody=Rabbit IgG [Sant

  17. Experiment list: SRX160915 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available M970828: IgG for CTCF SMC1; Homo sapiens; ChIP-Seq source_name=BCBL1 pleural effusion lymphoma, IgG ChIP || ...cell line=BCBL1 || cell type=KSHV-infected pleural effusion lymphoma cells || chip antibody=Mouse IgG [Santa

  18. Analysis of oversulfation in biglycan chondroitin/dermatan sulfate oligosaccharides by chip-based nanoelectrospray ionization multistage mass spectrometry.

    Science.gov (United States)

    Flangea, Corina; Sisu, Eugen; Seidler, Daniela G; Zamfir, Alina D

    2012-01-15

    Biglycan (BGN) is a small proteoglycan that consists of a protein core containing leucine-rich repeat regions and two glycosaminoglycan (GAG) chains of either chondroitin sulfate (CS) or dermatan sulfate (DS) type. The development of novel, highly efficient analytical methods for structural identification of BGN-derived CS/DS motifs, possibly implicated in biological events, is currently the focus of research. In this work, an improved analytical method based on fully automated chip-nanoelectrospray ionization (nanoESI) in conjunction with high-capacity ion trap (HCT) multistage mass spectrometry (MS) by collision-induced dissociation (CID) was for the first time applied to BGN CS/DS oligosaccharide analysis. The CS/DS chains were released from transfected 293 BGN by β-elimination. The chain was digested with AC I lyase, and the resulting mixture was purified and subsequently separated by size exclusion chromatography (SEC). Di- and tetrasaccharide fractions were pooled and characterized in detail using the developed chip-nanoESI protocol. The chip-nanoESI MS profile in the negative ion mode revealed the presence of under-, regularly, and oversulfated species in both di- and tetrasaccharide fractions. CID MS(2)-MS(3) yielded sequence patterns consistent with unusual oversulfated 4,5-Δ-GlcA(2S)-GalNAc(4S) and 4,5-Δ-GlcA(2S)-GalNAc(6S)-IdoA(2S)-GalNAc(6S) motifs. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Scratching experiments on quartz crystals: Orientation effects in chipping

    Science.gov (United States)

    Tellier, C. R.; Benmessaouda, D.

    1994-06-01

    The deformation and microfracture properties of quartz crystals were studied by scratching experiments. The critical load at which microfractures are initiated was found to be orientation dependent, whereas the average width of ductile grooves and chips remained relatively insensitive to crystal orientation. In contrast, a marked anisotropy in the shape of chips was observed. This anisotropy has been interpreted in terms of microfractures propagating preferentially along slip planes. Simple geometrical conditions for the SEM (scanning electron microscopy) observation of active slip planes are proposed.

  20. Ion Chromatography-on-a-chip for Water Quality Analysis

    Science.gov (United States)

    Kidd, R. D.; Noell, A.; Kazarians, G.; Aubrey, A. D.; Scianmarello, N.; Tai, Y.-C.

    2015-01-01

    We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

  1. 3D Printing of Organs-On-Chips

    Science.gov (United States)

    Yi, Hee-Gyeong; Lee, Hyungseok; Cho, Dong-Woo

    2017-01-01

    Organ-on-a-chip engineering aims to create artificial living organs that mimic the complex and physiological responses of real organs, in order to test drugs by precisely manipulating the cells and their microenvironments. To achieve this, the artificial organs should to be microfabricated with an extracellular matrix (ECM) and various types of cells, and should recapitulate morphogenesis, cell differentiation, and functions according to the native organ. A promising strategy is 3D printing, which precisely controls the spatial distribution and layer-by-layer assembly of cells, ECMs, and other biomaterials. Owing to this unique advantage, integration of 3D printing into organ-on-a-chip engineering can facilitate the creation of micro-organs with heterogeneity, a desired 3D cellular arrangement, tissue-specific functions, or even cyclic movement within a microfluidic device. Moreover, fully 3D-printed organs-on-chips more easily incorporate other mechanical and electrical components with the chips, and can be commercialized via automated massive production. Herein, we discuss the recent advances and the potential of 3D cell-printing technology in engineering organs-on-chips, and provides the future perspectives of this technology to establish the highly reliable and useful drug-screening platforms. PMID:28952489

  2. Emission of organic substances from chip-boards

    Energy Technology Data Exchange (ETDEWEB)

    Deppe, H.J.

    1982-01-01

    A relatively small number of investigations on emissions of organic substances from chip-board is available up to now. The emissions known to date are caused by glues or other additives rather than by the wood itself. As concerns aminoplast glues (urea-formaldehyde or melamine-formaldehyde resins) the most important point of public interest has been the off-gassing of formaldehyde from chip-board. Chip-board with phenol-formaldehyde glues has been known in some cases to give off phenol. The formation of diamino diphenyl methane from isocyanate glues is still a matter of discussion. A further source for possible emissions are wood and fire protectives which are added during the manufacturing process. Finally, coating of chip-board may lead to emissions of organic substances. The lack of adequate detection methods has so far delayed the treatment of questions in relation to emissions from chip-board. Even now, there are numerous problems in this field especially when investigating isocyanate glues. Problems in relation to the origin of emissions due to the kind of glue used and the manufacturing process are discussed, and proposals are made how to solve some of these problems. The question of the health risk is dealt with from the view-point of the civil engineer and in an general economic context.

  3. 3D Printing of Organs-On-Chips

    Directory of Open Access Journals (Sweden)

    Hee-Gyeong Yi

    2017-01-01

    Full Text Available Organ-on-a-chip engineering aims to create artificial living organs that mimic the complex and physiological responses of real organs, in order to test drugs by precisely manipulating the cells and their microenvironments. To achieve this, the artificial organs should to be microfabricated with an extracellular matrix (ECM and various types of cells, and should recapitulate morphogenesis, cell differentiation, and functions according to the native organ. A promising strategy is 3D printing, which precisely controls the spatial distribution and layer-by-layer assembly of cells, ECMs, and other biomaterials. Owing to this unique advantage, integration of 3D printing into organ-on-a-chip engineering can facilitate the creation of micro-organs with heterogeneity, a desired 3D cellular arrangement, tissue-specific functions, or even cyclic movement within a microfluidic device. Moreover, fully 3D-printed organs-on-chips more easily incorporate other mechanical and electrical components with the chips, and can be commercialized via automated massive production. Herein, we discuss the recent advances and the potential of 3D cell-printing technology in engineering organs-on-chips, and provides the future perspectives of this technology to establish the highly reliable and useful drug-screening platforms.

  4. Vertical Protocol Composition

    DEFF Research Database (Denmark)

    Groß, Thomas; Mödersheim, Sebastian Alexander

    2011-01-01

    The security of key exchange and secure channel protocols, such as TLS, has been studied intensively. However, only few works have considered what happens when the established keys are actually used—to run some protocol securely over the established “channel”. We call this a vertical protocol.......e., that the combination cannot introduce attacks that the individual protocols in isolation do not have. In this work, we prove a composability result in the symbolic model that allows for arbitrary vertical composition (including self-composition). It holds for protocols from any suite of channel and application...

  5. Genomic prediction of starch content and chipping quality in tetraploid potato using genotyping-by-sequencing

    DEFF Research Database (Denmark)

    Sverrisdóttir, Elsa; Byrne, Stephen; Nielsen, Ea Høegh Riis

    2017-01-01

    continue to fall. In this study, we have generated genomic prediction models for starch content and chipping quality in tetraploid potato to facilitate varietal development. Chipping quality was evaluated as the colour of a potato chip after frying following cold induced sweetening. We used genotyping...... genomic estimated breeding values. Cross-validated prediction correlations of 0.56 and 0.73 were obtained within the training population for starch content and chipping quality, respectively, while correlations were lower when predicting performance in the test panel, at 0.30–0.31 and 0...

  6. An automatic chip structure optical inspection system for electronic components

    Science.gov (United States)

    Song, Zhichao; Xue, Bindang; Liang, Jiyuan; Wang, Ke; Chen, Junzhang; Liu, Yunhe

    2018-01-01

    An automatic chip structure inspection system based on machine vision is presented to ensure the reliability of electronic components. It consists of four major modules, including a metallographic microscope, a Gigabit Ethernet high-resolution camera, a control system and a high performance computer. An auto-focusing technique is presented to solve the problem that the chip surface is not on the same focusing surface under the high magnification of the microscope. A panoramic high-resolution image stitching algorithm is adopted to deal with the contradiction between resolution and field of view, caused by different sizes of electronic components. In addition, we establish a database to storage and callback appropriate parameters to ensure the consistency of chip images of electronic components with the same model. We use image change detection technology to realize the detection of chip images of electronic components. The system can achieve high-resolution imaging for chips of electronic components with various sizes, and clearly imaging for the surface of chip with different horizontal and standardized imaging for ones with the same model, and can recognize chip defects.

  7. Analyzing the effect of routing protocols on media access control protocols in radio networks

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, C. L. (Christopher L.); Drozda, M. (Martin); Marathe, A. (Achla); Marathe, M. V. (Madhav V.)

    2002-01-01

    We study the effect of routing protocols on the performance of media access control (MAC) protocols in wireless radio networks. Three well known MAC protocols: 802.11, CSMA, and MACA are considered. Similarly three recently proposed routing protocols: AODV, DSR and LAR scheme 1 are considered. The experimental analysis was carried out using GloMoSim: a tool for simulating wireless networks. The main focus of our experiments was to study how the routing protocols affect the performance of the MAC protocols when the underlying network and traffic parameters are varied. The performance of the protocols was measured w.r.t. five important parameters: (i) number of received packets, (ii) average latency of each packet, (iii) throughput (iv) long term fairness and (v) number of control packets at the MAC layer level. Our results show that combinations of routing and MAC protocols yield varying performance under varying network topology and traffic situations. The result has an important implication; no combination of routing protocol and MAC protocol is the best over all situations. Also, the performance analysis of protocols at a given level in the protocol stack needs to be studied not locally in isolation but as a part of the complete protocol stack. A novel aspect of our work is the use of statistical technique, ANOVA (Analysis of Variance) to characterize the effect of routing protocols on MAC protocols. This technique is of independent interest and can be utilized in several other simulation and empirical studies.

  8. Effect of microwell chip structure on cell microsphere production of various animal cells.

    Science.gov (United States)

    Sakai, Yusuke; Yoshida, Shirou; Yoshiura, Yukiko; Mori, Rhuhei; Tamura, Tomoko; Yahiro, Kanji; Mori, Hideki; Kanemura, Yonehiro; Yamasaki, Mami; Nakazawa, Kohji

    2010-08-01

    The formation of three-dimensional cell microspheres such as spheroids, embryoid bodies, and neurospheres has attracted attention as a useful culture technique. In this study, we investigated a technique for effective cell microsphere production by using specially prepared microchip. The basic chip design was a multimicrowell structure in triangular arrangement within a 100-mm(2) region in the center of a polymethylmethacrylate (PMMA) plate (24x24 mm(2)), the surface of which was modified with polyethylene glycol (PEG) to render it nonadhesive to cells. We also designed six similar chips with microwell diameters of 200, 300, 400, 600, 800, and 1000 microm to investigate the effect of the microwell diameter on the cell microsphere diameter. Rat hepatocytes, HepG2 cells, mouse embryonic stem (ES) cells, and mouse neural progenitor/stem (NPS) cells formed hepatocyte spheroids, HepG2 spheroids, embryoid bodies, and neurospheres, respectively, in the microwells within 5 days of culture. For all the cells, a single microsphere was formed in each microwell under all the chip conditions, and such microsphere configurations remained throughout the culture period. Furthermore, the microsphere diameters of each type of cell were strongly positively correlated with the microwell diameters of the chips, suggesting that microsphere diameter can be factitiously controlled by using different chip conditions. Thus, this chip technique is a promising cellular platform for tissue engineering or regenerative medicine research, pharmacological and toxicological studies, and fundamental studies in cell biology. Copyright 2010 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  9. Transparent Nanopore Cavity Arrays Enable Highly Parallelized Optical Studies of Single Membrane Proteins on Chip.

    Science.gov (United States)

    Diederichs, Tim; Nguyen, Quoc Hung; Urban, Michael; Tampé, Robert; Tornow, Marc

    2018-06-13

    Membrane proteins involved in transport processes are key targets for pharmaceutical research and industry. Despite continuous improvements and new developments in the field of electrical readouts for the analysis of transport kinetics, a well-suited methodology for high-throughput characterization of single transporters with nonionic substrates and slow turnover rates is still lacking. Here, we report on a novel architecture of silicon chips with embedded nanopore microcavities, based on a silicon-on-insulator technology for high-throughput optical readouts. Arrays containing more than 14 000 inverted-pyramidal cavities of 50 femtoliter volumes and 80 nm circular pore openings were constructed via high-resolution electron-beam lithography in combination with reactive ion etching and anisotropic wet etching. These cavities feature both, an optically transparent bottom and top cap. Atomic force microscopy analysis reveals an overall extremely smooth chip surface, particularly in the vicinity of the nanopores, which exhibits well-defined edges. Our unprecedented transparent chip design provides parallel and independent fluorescent readout of both cavities and buffer reservoir for unbiased single-transporter recordings. Spreading of large unilamellar vesicles with efficiencies up to 96% created nanopore-supported lipid bilayers, which are stable for more than 1 day. A high lipid mobility in the supported membrane was determined by fluorescent recovery after photobleaching. Flux kinetics of α-hemolysin were characterized at single-pore resolution with a rate constant of 0.96 ± 0.06 × 10 -3 s -1 . Here, we deliver an ideal chip platform for pharmaceutical research, which features high parallelism and throughput, synergistically combined with single-transporter resolution.

  10. Experiment list: SRX153147 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available -Seq source_name=Human breast adenocarcinoma cell-line MCF7 || cell-line=MCF7 || passage=5 || chip antibody=...on=Pleura|Tissue Diagnosis=Adenocarcinoma 64054379,98.7,5.2,764 GSM946851: MCF7 H3K27me3; Homo sapiens; ChIP

  11. Experiment list: SRX153148 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available -Seq source_name=Human breast adenocarcinoma cell-line MCF7 || cell-line=MCF7 || passage=5 || chip antibody=...n=Pleura|Tissue Diagnosis=Adenocarcinoma 57306360,95.7,15.1,2666 GSM946852: MCF7 H3K9me3; Homo sapiens; ChIP

  12. On-chip integrated lasers for biophotonic applications

    DEFF Research Database (Denmark)

    Mappes, Timo; Wienhold, Tobias; Bog, Uwe

    Meeting the need of biomedical users, we develop disposable Lab-on-a-Chip systems based on commercially available polymers. We are combining passive microfluidics with active optical elements on-chip by integrating multiple solid-state and liquid-core lasers. While covering a wide range of laser ...

  13. Chip-olate’ and dry-film resists for efficient fabrication, singulation and sealing of microfluidic chips

    Science.gov (United States)

    Temiz, Yuksel; Delamarche, Emmanuel

    2014-09-01

    This paper describes a technique for high-throughput fabrication and efficient singulation of chips having closed microfluidic structures and takes advantage of dry-film resists (DFRs) for efficient sealing of capillary systems. The technique is illustrated using 4-inch Si/SiO2 wafers. Wafers carrying open microfluidic structures are partially diced to about half of their thickness. Treatments such as surface cleaning are done at wafer-level, then the structures are sealed using low-temperature (45 °C) lamination of a DFR that is pre-patterned using a craft cutter, and ready-to-use chips are finally separated manually like a chocolate bar by applying a small force (≤ 4 N). We further show that some DFRs have low auto-fluorescence at wavelengths typically used for common fluorescent dyes and that mechanical properties of some DFRs allow for the lamination of 200 μm wide microfluidic structures with negligible sagging (~1 μm). The hydrophilicity (advancing contact angle of ~60°) of the DFR supports autonomous capillary-driven flow without the need for additional surface treatment of the microfluidic chips. Flow rates from 1 to 5 µL min-1 are generated using different geometries of channels and capillary pumps. In addition, the ‘chip-olate’ technique is compatible with the patterning of capture antibodies on DFR for use in immunoassays. We believe this technique to be applicable to the fabrication of a wide range of microfluidic and lab-on-a-chip devices and to offer a viable alternative to many labor-intensive processes that are currently based on wafer bonding techniques or on the molding of poly(dimethylsiloxane) (PDMS) layers.

  14. Error Control for Network-on-Chip Links

    CERN Document Server

    Fu, Bo

    2012-01-01

    As technology scales into nanoscale regime, it is impossible to guarantee the perfect hardware design. Moreover, if the requirement of 100% correctness in hardware can be relaxed, the cost of manufacturing, verification, and testing will be significantly reduced. Many approaches have been proposed to address the reliability problem of on-chip communications. This book focuses on the use of error control codes (ECCs) to improve on-chip interconnect reliability. Coverage includes detailed description of key issues in NOC error control faced by circuit and system designers, as well as practical error control techniques to minimize the impact of these errors on system performance. Provides a detailed background on the state of error control methods for on-chip interconnects; Describes the use of more complex concatenated codes such as Hamming Product Codes with Type-II HARQ, while emphasizing integration techniques for on-chip interconnect links; Examines energy-efficient techniques for integrating multiple error...

  15. Characterisation of capacitively coupled HV/HR-CMOS sensor chips for the CLIC vertex detector

    CERN Document Server

    AUTHOR|(SzGeCERN)756402

    2017-01-01

    The capacitive coupling between an active sensor and a readout ASIC has been considered in the framework of the CLIC vertex detector study. The CLICpix Capacitively Coupled Pixel Detector (C3PD) is a High-Voltage CMOS sensor chip produced in a commercial 180 nm HV-CMOS process for this purpose. The sensor was designed to be connected to the CLICpix2 readout chip. It therefore matches the dimensions of the readout chip, featuring a matrix of 128 × 128 square pixels with 25 μm pitch. The sensor chip has been produced with the standard value for the substrate resistivity (∼ 20 Ωcm) and it has been characterised in standalone testing mode, before receiving and testing capacitively coupled assemblies. The standalone measurement results show a rise time of ∼ 20 ns for a power consumption of 5 μW/pixel. Production of the C3PD HV-CMOS sensor chip with higher substrate resistivity wafers (∼ 20, 80, 200 and 1000 Ωcm) is foreseen. The expected benefits of the higher substrate resistivity will be studied using...

  16. FISH & CHIPS: Four Electrode Conductivity / Salinity Sensor on a Silicon Multi-sensor chip for Fisheries Research

    DEFF Research Database (Denmark)

    Hyldgård, Anders; Olafsdottir, Iris; Olesen, M.

    2005-01-01

    The design and fabrication of a single chip silicon salinity, temperature, pressure and light multisensor is presented. The behavior 2- and 4-electrode conductivity microsensors are described and methods for precise determination of water conductivity are given......The design and fabrication of a single chip silicon salinity, temperature, pressure and light multisensor is presented. The behavior 2- and 4-electrode conductivity microsensors are described and methods for precise determination of water conductivity are given...

  17. Local structure of metallic chips examined by X-ray microdiffraction

    International Nuclear Information System (INIS)

    Saksl, K.; Rokicki, P.; Siemers, C.; Ostroushko, D.; Bednarčík, J.; Rütt, U.

    2013-01-01

    Highlights: •We present a detailed microstructure and phase analysis of chips produced by cutting. •3D analysis proved mixed nature of shear bands propagation to the material. •We examine phase composition of the chips by focused X-ray beam. •Crystallites in segment and shear band change their orientation up to 10°. -- Abstract: Nickel-base alloys are used in high-temperature applications whenever steels or titanium alloys cannot be applied anymore. This class of alloys is furthermore used in low-temperature applications in the oil or gas industry in case the corrosion resistance of stainless steels in related liquid media is not sufficient and titanium alloys would be too expensive. Nickel-base alloys, however, due to their high strength and toughness can be machined only at low cutting speeds as otherwise poor surface quality and enhanced tool wear is observed. From all aspects influencing the machinability, the chip formation mechanism is the key factor and only a thorough understanding of this mechanism can lead to an optimisation of the cutting process. In the current study, a detailed microstructure and phase analysis of Alloy 625 chips produced in an orthogonal cutting process at conventional cutting speeds is presented. Utilising hard monochromatic X-rays focused down to micrometre size, microstructural differences between distinct structural units of the chips, namely, the segments and shear bands, are investigated. Scanning cross sections of the chips with this small beam allowed us to determine misorientation between the segments and shear bands crystal lattices which as we found are not changing abruptly but continuously, with an absolute difference up to 10°

  18. A hidden Ising model for ChIP-chip data analysis

    KAUST Repository

    Mo, Q.

    2010-01-28

    Motivation: Chromatin immunoprecipitation (ChIP) coupled with tiling microarray (chip) experiments have been used in a wide range of biological studies such as identification of transcription factor binding sites and investigation of DNA methylation and histone modification. Hidden Markov models are widely used to model the spatial dependency of ChIP-chip data. However, parameter estimation for these models is typically either heuristic or suboptimal, leading to inconsistencies in their applications. To overcome this limitation and to develop an efficient software, we propose a hidden ferromagnetic Ising model for ChIP-chip data analysis. Results: We have developed a simple, but powerful Bayesian hierarchical model for ChIP-chip data via a hidden Ising model. Metropolis within Gibbs sampling algorithm is used to simulate from the posterior distribution of the model parameters. The proposed model naturally incorporates the spatial dependency of the data, and can be used to analyze data with various genomic resolutions and sample sizes. We illustrate the method using three publicly available datasets and various simulated datasets, and compare it with three closely related methods, namely TileMap HMM, tileHMM and BAC. We find that our method performs as well as TileMap HMM and BAC for the high-resolution data from Affymetrix platform, but significantly outperforms the other three methods for the low-resolution data from Agilent platform. Compared with the BAC method which also involves MCMC simulations, our method is computationally much more efficient. Availability: A software called iChip is freely available at http://www.bioconductor.org/. Contact: moq@mskcc.org. © The Author 2010. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org.

  19. Local structure of metallic chips examined by X-ray microdiffraction

    Energy Technology Data Exchange (ETDEWEB)

    Saksl, K., E-mail: ksaksl@imr.saske.sk [Institut of Materials Research, Slovak Academy of Sciences, Watsonova 47, 040 01 Košice (Slovakia); Rokicki, P. [The Faculty of Mechanical Engineering and Aeronautics, Rzeszow University of Technology, Al. Powstancow Warszawy 12, 35-959 Rzeszow (Poland); Siemers, C. [Institut fuer Werkstoffe, Technische Universitaet Braunschweig, Langer Kamp 8, 38106 Braunschweig (Germany); Ostroushko, D. [Faculty of Metallurgy and Materials Engineering, VŠB – Technical University of Ostrava, 17.listopadu 15, 708 33 Ostrava (Czech Republic); Bednarčík, J.; Rütt, U. [HASYLAB at DESY, Notkestr. 85, D-22607 Hamburg (Germany)

    2013-12-25

    Highlights: •We present a detailed microstructure and phase analysis of chips produced by cutting. •3D analysis proved mixed nature of shear bands propagation to the material. •We examine phase composition of the chips by focused X-ray beam. •Crystallites in segment and shear band change their orientation up to 10°. -- Abstract: Nickel-base alloys are used in high-temperature applications whenever steels or titanium alloys cannot be applied anymore. This class of alloys is furthermore used in low-temperature applications in the oil or gas industry in case the corrosion resistance of stainless steels in related liquid media is not sufficient and titanium alloys would be too expensive. Nickel-base alloys, however, due to their high strength and toughness can be machined only at low cutting speeds as otherwise poor surface quality and enhanced tool wear is observed. From all aspects influencing the machinability, the chip formation mechanism is the key factor and only a thorough understanding of this mechanism can lead to an optimisation of the cutting process. In the current study, a detailed microstructure and phase analysis of Alloy 625 chips produced in an orthogonal cutting process at conventional cutting speeds is presented. Utilising hard monochromatic X-rays focused down to micrometre size, microstructural differences between distinct structural units of the chips, namely, the segments and shear bands, are investigated. Scanning cross sections of the chips with this small beam allowed us to determine misorientation between the segments and shear bands crystal lattices which as we found are not changing abruptly but continuously, with an absolute difference up to 10°.

  20. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  1. Exploration within the Network-on-Chip Paradigm

    NARCIS (Netherlands)

    Wolkotte, P.T.

    2009-01-01

    A general purpose processor used to consist of a single processing core, which performed and controlled all tasks on the chip. Its functionality and maximum clock frequency grew steadily over the years. Due to the continuous increase of the number of transistors available on-chip and the operational

  2. Experiment list: SRX119679 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 8,18360 GSM874985: ES.H3K27me3; Homo sapiens; ChIP-Seq source_name=H1 human Embryonic stem cells || cell line=H1 || treatment=diagnos...tic sample (pre-treatment) || chip antibody=H3K27me3 || chip antibody manufacturer=

  3. Experiment list: SRX119684 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 2,13603 GSM874990: ES.H3K79me2; Homo sapiens; ChIP-Seq source_name=H1 human Embryonic stem cell || cell line=H1 || treatment=diagnost...ic sample (pre-treatment) || chip antibody=H3K79me2 || chip antibody manufacturer=A

  4. Modelling the clamping force distribution among chips in press-pack IGBTs using the finite element method

    DEFF Research Database (Denmark)

    Hasmasan, Adrian Augustin; Busca, Christian; Teodorescu, Remus

    2012-01-01

    In this paper, a FEM (finite element method) based mechanical model for PP (press-pack) IGBTs (insulated gate bipolar transistors) is presented, which can be used to calculate the clamping force distribution among chips under various clamping conditions. The clamping force is an important parameter...... for the chip, because it influences contact electrical resistance, contact thermal resistance and power cycling capability. Ideally, the clamping force should be equally distributed among chips, in order to maximize the reliability of the PP IGBT. The model is built around a hypothetical PP IGBT with 9 chips......, and it has numerous simplifications in order to reduce the simulation time as much as possible. The developed model is used to analyze the clamping force distribution among chips, in various study cases, where uniform and non-uniform clamping pressures are applied on the studied PP IGBT....

  5. Self-powered integrated systems-on-chip (energy chip)

    KAUST Repository

    Hussain, Muhammad Mustafa

    2010-04-23

    In today\\'s world, consumer driven technology wants more portable electronic gadgets to be developed, and the next big thing in line is self-powered handheld devices. Therefore to reduce the power consumption as well as to supply sufficient power to run those devices, several critical technical challenges need to be overcome: a. Nanofabrication of macro/micro systems which incorporates the direct benefit of light weight (thus portability), low power consumption, faster response, higher sensitivity and batch production (low cost). b. Integration of advanced nano-materials to meet the performance/cost benefit trend. Nano-materials may offer new functionalities that were previously underutilized in the macro/micro dimension. c. Energy efficiency to reduce power consumption and to supply enough power to meet that low power demand. We present a pragmatic perspective on a self-powered integrated System on Chip (SoC). We envision the integrated device will have two objectives: low power consumption/dissipation and on-chip power generation for implementation into handheld or remote technologies for defense, space, harsh environments and medical applications. This paper provides insight on materials choices, intelligent circuit design, and CMOS compatible integration.

  6. Self-powered integrated systems-on-chip (energy chip)

    Science.gov (United States)

    Hussain, M. M.; Fahad, H.; Rojas, J.; Hasan, M.; Talukdar, A.; Oommen, J.; Mink, J.

    2010-04-01

    In today's world, consumer driven technology wants more portable electronic gadgets to be developed, and the next big thing in line is self-powered handheld devices. Therefore to reduce the power consumption as well as to supply sufficient power to run those devices, several critical technical challenges need to be overcome: a. Nanofabrication of macro/micro systems which incorporates the direct benefit of light weight (thus portability), low power consumption, faster response, higher sensitivity and batch production (low cost). b. Integration of advanced nano-materials to meet the performance/cost benefit trend. Nano-materials may offer new functionalities that were previously underutilized in the macro/micro dimension. c. Energy efficiency to reduce power consumption and to supply enough power to meet that low power demand. We present a pragmatic perspective on a self-powered integrated System on Chip (SoC). We envision the integrated device will have two objectives: low power consumption/dissipation and on-chip power generation for implementation into handheld or remote technologies for defense, space, harsh environments and medical applications. This paper provides insight on materials choices, intelligent circuit design, and CMOS compatible integration.

  7. Chip-Oriented Fluorimeter Design and Detection System Development for DNA Quantification in Nano-Liter Volumes

    Directory of Open Access Journals (Sweden)

    Da-Sheng Lee

    2009-12-01

    Full Text Available The chip-based polymerase chain reaction (PCR system has been developed in recent years to achieve DNA quantification. Using a microstructure and miniature chip, the volume consumption for a PCR can be reduced to a nano-liter. With high speed cycling and a low reaction volume, the time consumption of one PCR cycle performed on a chip can be reduced. However, most of the presented prototypes employ commercial fluorimeters which are not optimized for fluorescence detection of such a small quantity sample. This limits the performance of DNA quantification, especially low experiment reproducibility. This study discusses the concept of a chip-oriented fluorimeter design. Using the analytical model, the current study analyzes the sensitivity and dynamic range of the fluorimeter to fit the requirements for detecting fluorescence in nano-liter volumes. Through the optimized processes, a real-time PCR on a chip system with only one nano-liter volume test sample is as sensitive as the commercial real-time PCR machine using the sample with twenty micro-liter volumes. The signal to noise (S/N ratio of a chip system for DNA quantification with hepatitis B virus (HBV plasmid samples is 3 dB higher. DNA quantification by the miniature chip shows higher reproducibility compared to the commercial machine with respect to samples of initial concentrations from 103 to 105 copies per reaction.

  8. Effect of chipping on emergence of the redbay ambrosia beetle (Coleoptera: Curculionidae: Scolytinae) and recovery of the laurel wilt pathogen from infested wood chips.

    Science.gov (United States)

    Spence, D J; Smith, J A; Ploetz, R; Hulcr, J; Stelinski, L L

    2013-10-01

    Significant mortality ofredbay trees (Persea borbonia (L.) Spreng.) in the southeastern United States has been caused by Raffaelea lauricola, T.C. Harr., Fraedrich, & Aghayeva (Harrington et al. 2008), a fungal symbiont of the exotic redbay ambrosia beetle, Xyleborus glabratus, Eichhoff (Fraedrich et al. 2008). This pathogen causes laurel wilt, which is an irreversible disease that can kill mature trees within a few weeks in summer. R. lauricola has been shown to be lethal to most native species of Lauraceae and cultivated avocado (Persea americana Mill.) in the southeastern United States. In this study, we examined the survival of X. glabratus and R. lauricola in wood chips made from infested trees by using a standard tree chipper over a 10-wk period. After 2 wk, 14 X. glabratus were recovered from wood chips, whereas 339 X. glabratus emerged from nonchipped bolts. R. lauricola was not found 2 d postchipping from wood chips, indicating that the pathogen is not likely to survive for long inside wood chips. In contrast, R. lauricola persisted in dead, standing redbay trees for 14 mo. With large volumes of wood, the potential for infested logs to be moved between states or across U.S. borders is significant. Results demonstrated that chipping wood from laurel wilt-killed trees can significantly reduce the number of X. glabratus and limit the persistence of R. lauricola, which is important for sanitation strategies aimed at limiting the spread of this disease.

  9. Characterization of Ni/SnPb-TiW/Pt Flip Chip Interconnections in Silicon Pixel Detector Modules

    CERN Document Server

    Karadzhinova, Aneliya; Härkönen, Jaakko; Luukka, Panja-riina; Mäenpää, Teppo; Tuominen, Eija; Haeggstrom, Edward; Kalliopuska, Juha; Vahanen, Sami; Kassamakov, Ivan

    2014-01-01

    In contemporary high energy physics experiments, silicon detectors are essential for recording the trajectory of new particles generated by multiple simultaneous collisions. Modern particle tracking systems may feature 100 million channels, or pixels, which need to be individually connected to read-out chains. Silicon pixel detectors are typically connected to readout chips by flip-chip bonding using solder bumps. High-quality electro-mechanical flip-chip interconnects minimizes the number of dead read-out channels in the particle tracking system. Furthermore, the detector modules must endure handling during installation and withstand heat generation and cooling during operation. Silicon pixel detector modules were constructed by flip-chip bonding 16 readout chips to a single sensor. Eutectic SnPb solder bumps were deposited on the readout chips and the sensor chips were coated with TiW/Pt thin film UBM (under bump metallization). The modules were assembled at Advacam Ltd, Finland. We studied the uniformity o...

  10. A Neuron- and a Synapse Chip for Artificial Neural Networks

    DEFF Research Database (Denmark)

    Lansner, John; Lehmann, Torsten

    1992-01-01

    A cascadable, analog, CMOS chip set has been developed for hardware implementations of artificial neural networks (ANN's):I) a neuron chip containing an array of neurons with hyperbolic tangent activation functions and adjustable gains, and II) a synapse chip (or a matrix-vector multiplier) where...

  11. A polymer chip-integrable piezoelectric micropump with low backpressure dependence

    DEFF Research Database (Denmark)

    Conde, A. J.; Bianchetti, A.; Veiras, F. E.

    2015-01-01

    We describe a piezoelectric micropump constructed in polymers with conventional machining methods. The micropump is self-contained and can be built as an independent device or as an on-chip module within laminated microfluidic chips. We demonstrate on-chip integrability by the fabrication and tes...

  12. A Microfluidic Device for Preparing Next Generation DNA Sequencing Libraries and for Automating Other Laboratory Protocols That Require One or More Column Chromatography Steps

    Science.gov (United States)

    Tan, Swee Jin; Phan, Huan; Gerry, Benjamin Michael; Kuhn, Alexandre; Hong, Lewis Zuocheng; Min Ong, Yao; Poon, Polly Suk Yean; Unger, Marc Alexander; Jones, Robert C.; Quake, Stephen R.; Burkholder, William F.

    2013-01-01

    Library preparation for next-generation DNA sequencing (NGS) remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation. PMID:23894273

  13. A microfluidic device for preparing next generation DNA sequencing libraries and for automating other laboratory protocols that require one or more column chromatography steps.

    Directory of Open Access Journals (Sweden)

    Swee Jin Tan

    Full Text Available Library preparation for next-generation DNA sequencing (NGS remains a key bottleneck in the sequencing process which can be relieved through improved automation and miniaturization. We describe a microfluidic device for automating laboratory protocols that require one or more column chromatography steps and demonstrate its utility for preparing Next Generation sequencing libraries for the Illumina and Ion Torrent platforms. Sixteen different libraries can be generated simultaneously with significantly reduced reagent cost and hands-on time compared to manual library preparation. Using an appropriate column matrix and buffers, size selection can be performed on-chip following end-repair, dA tailing, and linker ligation, so that the libraries eluted from the chip are ready for sequencing. The core architecture of the device ensures uniform, reproducible column packing without user supervision and accommodates multiple routine protocol steps in any sequence, such as reagent mixing and incubation; column packing, loading, washing, elution, and regeneration; capture of eluted material for use as a substrate in a later step of the protocol; and removal of one column matrix so that two or more column matrices with different functional properties can be used in the same protocol. The microfluidic device is mounted on a plastic carrier so that reagents and products can be aliquoted and recovered using standard pipettors and liquid handling robots. The carrier-mounted device is operated using a benchtop controller that seals and operates the device with programmable temperature control, eliminating any requirement for the user to manually attach tubing or connectors. In addition to NGS library preparation, the device and controller are suitable for automating other time-consuming and error-prone laboratory protocols requiring column chromatography steps, such as chromatin immunoprecipitation.

  14. Generation of segmental chips in metal cutting modeled with the PFEM

    Science.gov (United States)

    Rodriguez Prieto, J. M.; Carbonell, J. M.; Cante, J. C.; Oliver, J.; Jonsén, P.

    2017-09-01

    The Particle Finite Element Method, a lagrangian finite element method based on a continuous Delaunay re-triangulation of the domain, is used to study machining of Ti6Al4V. In this work the method is revised and applied to study the influence of the cutting speed on the cutting force and the chip formation process. A parametric methodology for the detection and treatment of the rigid tool contact is presented. The adaptive insertion and removal of particles are developed and employed in order to sidestep the difficulties associated with mesh distortion, shear localization as well as for resolving the fine-scale features of the solution. The performance of PFEM is studied with a set of different two-dimensional orthogonal cutting tests. It is shown that, despite its Lagrangian nature, the proposed combined finite element-particle method is well suited for large deformation metal cutting problems with continuous chip and serrated chip formation.

  15. Determining wood chip size: image analysis and clustering methods

    Directory of Open Access Journals (Sweden)

    Paolo Febbi

    2013-09-01

    Full Text Available One of the standard methods for the determination of the size distribution of wood chips is the oscillating screen method (EN 15149- 1:2010. Recent literature demonstrated how image analysis could return highly accurate measure of the dimensions defined for each individual particle, and could promote a new method depending on the geometrical shape to determine the chip size in a more accurate way. A sample of wood chips (8 litres was sieved through horizontally oscillating sieves, using five different screen hole diameters (3.15, 8, 16, 45, 63 mm; the wood chips were sorted in decreasing size classes and the mass of all fractions was used to determine the size distribution of the particles. Since the chip shape and size influence the sieving results, Wang’s theory, which concerns the geometric forms, was considered. A cluster analysis on the shape descriptors (Fourier descriptors and size descriptors (area, perimeter, Feret diameters, eccentricity was applied to observe the chips distribution. The UPGMA algorithm was applied on Euclidean distance. The obtained dendrogram shows a group separation according with the original three sieving fractions. A comparison has been made between the traditional sieve and clustering results. This preliminary result shows how the image analysis-based method has a high potential for the characterization of wood chip size distribution and could be further investigated. Moreover, this method could be implemented in an online detection machine for chips size characterization. An improvement of the results is expected by using supervised multivariate methods that utilize known class memberships. The main objective of the future activities will be to shift the analysis from a 2-dimensional method to a 3- dimensional acquisition process.

  16. Experiment list: SRX507384 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available + (wildtype) || age of animals=1-5 day old || tissue=Ovaries || chip antibody=Anti-H3K4me2 || chip antibody ... Anti-H3K4me2- replicate#2; Drosophila melanogaster; ChIP-Seq source_name=WT_WT_Anti-H3K4me2 || strain=piwi/

  17. Experiment list: SRX507382 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available + (wildtype) || age of animals=1-5 day old || tissue=Ovaries || chip antibody=Anti-H3K9me3 || chip antibody ... Anti-H3K9me3- replicate#2; Drosophila melanogaster; ChIP-Seq source_name=WT_WT_Anti-H3K9me3 || strain=piwi/

  18. Experiment list: SRX037432 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available s from PBMC, normal || gender=male || cell type=aTconv cells || chip antibody=H3K4me1 || chip antibody vendo...=peripheral blood mononuclear cells 14792460,17.0,2.9,5804 GSM648494: aTconv-H3K4me1 source_name=aTconv cell

  19. Diffusion driven optofluidic dye lasers encapsulated into polymer chips

    DEFF Research Database (Denmark)

    Wienhold, Tobias; Breithaupt, Felix; Vannahme, Christoph

    2012-01-01

    Lab-on-a-chip systems made of polymers are promising for the integration of active optical elements, enabling e.g. on-chip excitation of fluorescent markers or spectroscopy. In this work we present diffusion operation of tunable optofluidic dye lasers in a polymer foil. We demonstrate that these ......Lab-on-a-chip systems made of polymers are promising for the integration of active optical elements, enabling e.g. on-chip excitation of fluorescent markers or spectroscopy. In this work we present diffusion operation of tunable optofluidic dye lasers in a polymer foil. We demonstrate...... that these first order distributed feedback lasers can be operated for more than 90 min at a pulse repetition rate of 2 Hz without fluidic pumping. Ultra-high output pulse energies of more than 10 μJ and laser thresholds of 2 μJ are achieved for resonator lengths of 3 mm. By introducing comparatively large on......-chip dye solution reservoirs, the required exchange of dye molecules is accomplished solely by diffusion. Polymer chips the size of a microscope cover slip (18 × 18 mm2) were fabricated in batches on a wafer using a commercially available polymer (TOPAS® Cyclic Olefin Copolymer). Thermal imprinting...

  20. Prototype detection unit for the CHIPS experiment

    Science.gov (United States)

    Pfützner, Maciej M.

    2017-09-01

    CHIPS (CHerenkov detectors In mine PitS) is an R&D project aiming to develop novel cost-effective neutrino detectors, focused on measuring the CP-violating neutrino mixing phase (δ CP). A single detector module, containing an enclosed volume of purified water, would be submerged in an existing lake, located in a neutrino beam. A staged approach is proposed with first detectors deployed in a flooded mine pit in Northern Minnesota, 7 mrad off-axis from the existing NuMI beam. A small proof-of-principle model (CHIPS-M) has already been tested and the first stage of a fully functional 10 kt module (CHIPS-10) is planned for 2018. One of the instruments submerged on board of CHIPS-M in autumn 2015 was a prototype detection unit, constructed at Nikhef. The unit contains hardware borrowed from the KM3NeT experiment, including 16 3 inch photomultiplier tubes and readout electronics. In addition to testing the mechanical design and data acquisition, the detector was used to record a large sample of cosmic ray muon events. The collected data is valuable for characterising the cosmic muon background and validating a Monte Carlo simulation used to optimise future designs. This paper introduces the CHIPS project, describes the design of the prototype unit, and presents the results of a preliminary data analysis.

  1. CHIP promotes thyroid cancer proliferation via activation of the MAPK and AKT pathways

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Li [Department of Pharmacy, Urumchi General Hospital of Lanzhou Military Region, Urumchi, Xinjiang 830000 (China); Liu, Lianyong [Medical College of Soochow University, Suzhou, Jiangsu 215123 (China); Department of Endocrinology, Shanghai Punan Hospital, Shanghai 200125 (China); He, Xiaohua; Shen, Yunling; Liu, Xuerong; Wei, Jing; Yu, Fang [Department of Endocrinology, Urumchi General Hospital of Lanzhou Military Region, Urumchi, Xinjiang 830000 (China); Tian, Jianqing, E-mail: jianqing0991@163.com [Department of Endocrinology, Urumchi General Hospital of Lanzhou Military Region, Urumchi, Xinjiang 830000 (China)

    2016-08-26

    The carboxyl terminus of Hsp70-interacting protein (CHIP) is a U box-type ubiquitin ligase that plays crucial roles in various biological processes, including tumor progression. To date, the functional mechanism of CHIP in thyroid cancer remains unknown. Here, we obtained evidence of upregulation of CHIP in thyroid cancer tissues and cell lines. CHIP overexpression markedly enhanced thyroid cancer cell viability and colony formation in vitro and accelerated tumor growth in vivo. Conversely, CHIP knockdown impaired cell proliferation and tumor growth. Notably, CHIP promoted cell growth through activation of MAPK and AKT pathways, subsequently decreasing p27 and increasing cyclin D1 and p-FOXO3a expression. Our findings collectively indicate that CHIP functions as an oncogene in thyroid cancer, and is therefore a potential therapeutic target for this disease. - Highlights: • CHIP is significantly upregulated in thyroid cancer cells. • Overexpression of CHIP facilitates proliferation and tumorigenesis of thyroid cancer cells. • Silencing of CHIP inhibits the proliferation and tumorigenesis of thyroid cancer cells. • CHIP promotes thyroid cancer cell proliferation via activating the MAPK and AKT pathways.

  2. Fabrication and characterization of SPR chips with the modified bovine serum albumin

    Science.gov (United States)

    Chen, Xing; Zhang, Lu-lu; Cui, Da-fu

    2016-03-01

    A facile surface plasmon resonance (SPR) chip is developed for small molecule determination and analysis. The SPR chip was prepared based on a self assembling principle, in which the modified bovine serum albumin (BSA) was directly self-assembled onto the bare gold surface. The surface morphology of the chip with the modified BSA was investigated by atomic force microscopy (AFM) and its optical properties were characterized. The surface binding capacity of the bare facile SPR chip with a uniform morphology is 8 times of that of the bare control SPR chip. Based on the experiments of immune reaction between cortisol antibody and cortisol derivative, the sensitivity of the facile SPR chip with the modified BSA is much higher than that of the control SPR chip with the un-modified BSA. The facile SPR chip has been successfully used to detect small molecules. The lowest detection limit is 5 ng/mL with a linear range of 5—100 ng/mL for cortisol analysis. The novel facile SPR chip can also be applied to detect other small molecules.

  3. Chip-olate’ and dry-film resists for efficient fabrication, singulation and sealing of microfluidic chips

    International Nuclear Information System (INIS)

    Temiz, Yuksel; Delamarche, Emmanuel

    2014-01-01

    This paper describes a technique for high-throughput fabrication and efficient singulation of chips having closed microfluidic structures and takes advantage of dry-film resists (DFRs) for efficient sealing of capillary systems. The technique is illustrated using 4-inch Si/SiO 2 wafers. Wafers carrying open microfluidic structures are partially diced to about half of their thickness. Treatments such as surface cleaning are done at wafer-level, then the structures are sealed using low-temperature (45 °C) lamination of a DFR that is pre-patterned using a craft cutter, and ready-to-use chips are finally separated manually like a chocolate bar by applying a small force (≤ 4 N). We further show that some DFRs have low auto-fluorescence at wavelengths typically used for common fluorescent dyes and that mechanical properties of some DFRs allow for the lamination of 200 μm wide microfluidic structures with negligible sagging (∼1 μm). The hydrophilicity (advancing contact angle of ∼60°) of the DFR supports autonomous capillary-driven flow without the need for additional surface treatment of the microfluidic chips. Flow rates from 1 to 5 µL min -1 are generated using different geometries of channels and capillary pumps. In addition, the ‘chip-olate’ technique is compatible with the patterning of capture antibodies on DFR for use in immunoassays. We believe this technique to be applicable to the fabrication of a wide range of microfluidic and lab-on-a-chip devices and to offer a viable alternative to many labor-intensive processes that are currently based on wafer bonding techniques or on the molding of poly(dimethylsiloxane) (PDMS) layers. (technical note)

  4. Experiment list: SRX176067 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available sis=Carcinoma 6619400,91.7,7.2,13648 GSM984399: LNCAP H3K4ME3 vehicle; Homo sapiens; ChIP-Seq source_name=pr...ostate cancer cells || cell line=LNCaP || chip antibody=H3K4Me3 || chip antibody manufacturer=Millipore || treatment=EtOH vehicle

  5. Experiment list: SRX485219 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available 56 GSM1346560: RNA Polymerase II ChIP from control germline knock-down ovaries; Drosophila melanogaster; ChI...P-Seq source_name=RNA Polymerase II ChIP from control germline knock-down ovaries || developmental stage=4-6... days old adult || Sex=female || tissue=ovary || germline knock-down=control || c

  6. Experiment list: SRX107410 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Adenocarcinoma 37378122,96.3,56.7,376 GSM838388: h3k36me3 si23 ChIP-Seq; Homo sapiens; ChIP-Seq source_name=Hela cells knock...down Med23 || chip antibody=H3K36me3 || treatment=knockdown Med23 || cell line=HeLa || chip

  7. Effect of residual chips on the material removal process of the bulk metallic glass studied by in situ scratch testing inside the scanning electron microscope

    Directory of Open Access Journals (Sweden)

    Hu Huang

    2012-12-01

    Full Text Available Research on material removal mechanism is meaningful for precision and ultra-precision manufacturing. In this paper, a novel scratch device was proposed by integrating the parasitic motion principle linear actuator. The device has a compact structure and it can be installed on the stage of the scanning electron microscope (SEM to carry out in situ scratch testing. Effect of residual chips on the material removal process of the bulk metallic glass (BMG was studied by in situ scratch testing inside the SEM. The whole removal process of the BMG during the scratch was captured in real time. Formation and growth of lamellar chips on the rake face of the Cube-Corner indenter were observed dynamically. Experimental results indicate that when lots of chips are accumulated on the rake face of the indenter and obstruct forward flow of materials, materials will flow laterally and downward to find new location and direction for formation of new chips. Due to similar material removal processes, in situ scratch testing is potential to be a powerful research tool for studying material removal mechanism of single point diamond turning, single grit grinding, mechanical polishing and grating fabrication.

  8. Standardization of a Videofluoroscopic Swallow Study Protocol to Investigate Dysphagia in Dogs.

    Science.gov (United States)

    Harris, R A; Grobman, M E; Allen, M J; Schachtel, J; Rawson, N E; Bennett, B; Ledyayev, J; Hopewell, B; Coates, J R; Reinero, C R; Lever, T E

    2017-03-01

    Videofluoroscopic swallow study (VFSS) is the gold standard for diagnosis of dysphagia in veterinary medicine but lacks standardized protocols that emulate physiologic feeding practices. Age impacts swallow function in humans but has not been evaluated by VFSS in dogs. To develop a protocol with custom kennels designed to allow free-feeding of 3 optimized formulations of contrast media and diets that address limitations of current VFSS protocols. We hypothesized that dogs evaluated by a free-feeding VFSS protocol would show differences in objective swallow metrics based on age. Healthy juvenile, adult, and geriatric dogs (n = 24). Prospective, experimental study. Custom kennels were developed to maintain natural feeding behaviors during VFSS. Three food consistencies (thin liquid, pureed food, and dry kibble) were formulated with either iohexol or barium to maximize palatability and voluntary prehension. Dogs were evaluated by 16 swallow metrics and compared across age groups. Development of a standardized VFSS protocol resulted in successful collection of swallow data in healthy dogs. No significant differences in swallow metrics were observed among age groups. Substantial variability was observed in healthy dogs when evaluated under these physiologic conditions. Features typically attributed to pathologic states, such as gastric reflux, were seen in healthy dogs. Development of a VFSS protocol that reflects natural feeding practices may allow emulation of physiology resulting in clinical signs of dysphagia. Age did not result in significant changes in swallow metrics, but additional studies are needed, particularly in light of substantial normal variation. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  9. Chips in banknotes for a banknote electronic signature

    Science.gov (United States)

    Perron, Maurice; Grimal, Jean-Michel; Beauchet, Frederic; Dell'Ova, Francis

    2004-06-01

    A lot of information can be found in the media about the possibility of using micro-chips in banknotes. This mostly comes from chip manufacturers whose technology is becoming mature for this application. A lot of patents have been applied therefore but what must be noticed is that all these patents concern the processes to insert chips in banknotes and not a lot is said about the product itself and for what use. The Banque de France is a Central Bank involved in all tasks concerning banknotes from design, production, issue, recirculation and sorting, action against counterfeiting and finally destruction. These activities concern, of course, the banknotes in circulation in France (formerly the French francs notes, presently the Euro notes as Banque de France is part of the Eurosystem) and in other countries in the world. The Banque de France approach in looking to the future of chips in banknotes is at first a product approach. Banknotes are means of payment for which security of authentication is fundamental. They could carry chips to provide more security in the transactions but without altering their nature: the anonyminity and immediacy of the transactions.

  10. Simple photolithographic rapid prototyping of microfluidic chips

    DEFF Research Database (Denmark)

    Kunstmann-Olsen, Casper; Hoyland, James; Rubahn, Horst-Günter

    2012-01-01

    Vi præsenterer en simpel metode til at producere støbeforme til støbning af PDMS mikrofluide chips vha. fotolitografi, med 35mm fotonegativer som masker. Vi demonstrer metodens muligheder og begrænsninger. Vi har optimeret processen til at fremstille planare lab-on-a-chip strukturer med meget høj...

  11. New immobilisation protocol for the template used in solid-phase synthesis of MIP nanoparticles

    Science.gov (United States)

    Chen, Lu; Muhammad, Turghun; Yakup, Burabiye; Piletsky, Sergey A.

    2017-06-01

    As a novel imprinting method, solid-phase synthesis has proven to be a promising approach to prepare polymer nanoparticles with specific recognition sites for a template molecule. In this method, imprinted polymer nanoparticles were synthesized using template immobilized on a solid support. Herein, preparation of immobilized templates on quartz chips through homogeneous route was reported as an efficient alternative strategy to heterogeneous one. The template molecule indole-3-butyric acid (IBA) was reacted with 3-aminopropyltriethoxysilane (APTES) to produce silylated template (IBA-APTES), and it was characterized by IR, 1H NMR and GC-MS. Then, the silylated template molecule was grafted onto the activated surfaces of quartz chip to prepare immobilized template (SiO2@IBA-APTES). The immobilization was confirmed by contact angle, XPS, UV and fluorescence measurement. Immobilization protocol has shown good reproducibility and stability of the immobilized template. MIP nanoparticles were prepared with high selectivity toward the molecule immobilized onto the solid surface. This provides a new approach for the development of molecularly imprinted nanoparticles.

  12. Microengineered physiological biomimicry: organs-on-chips.

    Science.gov (United States)

    Huh, Dongeun; Torisawa, Yu-suke; Hamilton, Geraldine A; Kim, Hyun Jung; Ingber, Donald E

    2012-06-21

    Microscale engineering technologies provide unprecedented opportunities to create cell culture microenvironments that go beyond current three-dimensional in vitro models by recapitulating the critical tissue-tissue interfaces, spatiotemporal chemical gradients, and dynamic mechanical microenvironments of living organs. Here we review recent advances in this field made over the past two years that are focused on the development of 'Organs-on-Chips' in which living cells are cultured within microfluidic devices that have been microengineered to reconstitute tissue arrangements observed in living organs in order to study physiology in an organ-specific context and to develop specialized in vitro disease models. We discuss the potential of organs-on-chips as alternatives to conventional cell culture models and animal testing for pharmaceutical and toxicology applications. We also explore challenges that lie ahead if this field is to fulfil its promise to transform the future of drug development and chemical safety testing.

  13. Monitoring moisture content, temperature, and humidity in whole-tree pine chip piles

    Science.gov (United States)

    John Klepac; Dana Mitchell; Jason Thompson

    2015-01-01

    Two whole-tree chip piles were monitored for moisture content, temperature, and relative humidity from October 8th, 2010 to March 16th, 2011 at a location in south Alabama. Initial moisture content samples were collected immediately after chips were delivered to the study location on October 8th for Pile 1 and October 22nd for Pile 2. During pile construction, Lascar...

  14. Microfluidic organ-on-chip technology for blood-brain barrier research

    NARCIS (Netherlands)

    van der Helm, Marieke Willemijn; van der Meer, Andries Dirk; Eijkel, Jan C.T.; van den Berg, Albert; Segerink, Loes Irene

    2016-01-01

    Organs-on-chips are a new class of microengineered laboratory models that combine several of the advantages of current in vivo and in vitro models. In this review, we summarize the advances that have been made in the development of organ-on-chip models of the blood-brain barrier (BBBs-on-chips) and

  15. Experiment list: SRX150629 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available sue Diagnosis=Fibrocystic Disease 27949151,89.1,5.9,589 GSM935550: Harvard ChipSeq MCF10A-Er-Src EtOH 0.01pc...t 12hr Input std source_name=MCF10A-Er-Src || biomaterial_provider=Struhl laboratory || lab=Harvard || lab description=Struhl - Harva...rd University || datatype=ChipSeq || datatype descriptio

  16. Experiment list: SRX150494 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available n-Barr Virus 44912180,85.6,7.7,1806 GSM935415: Harvard ChipSeq GM12878 GCN5 std source_name=GM12878 || bioma...ard || lab description=Struhl - Harvard University || datatype=ChipSeq || datatype ...terial_provider=Coriell; http://ccr.coriell.org/Sections/Search/Search.aspx?PgId=165&q=GM12878 || lab=Harv

  17. Experiment list: SRX150667 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available t|Tissue Diagnosis=Fibrocystic Disease 69172664,86.5,35.3,28780 GSM935588: Harvard ChipSeq MCF10A-Er-Src EtO...H 0.01pct Pol2 std source_name=MCF10A-Er-Src || biomaterial_provider=Struhl laboratory || lab=Harvard || lab description=Struhl - Har...vard University || datatype=ChipSeq || datatype descript

  18. Experiment list: SRX150535 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available t|Tissue Diagnosis=Fibrocystic Disease 69171580,86.8,43.7,20874 GSM935456: Harvard ChipSeq MCF10A-Er-Src 4OH...TAM 1uM 36hr Pol2 std source_name=MCF10A-Er-Src || biomaterial_provider=Struhl laboratory || lab=Harvard || ...lab description=Struhl - Harvard University || datatype=ChipSeq || datatype descr

  19. Experiment list: SRX150562 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available -Barr Virus 57294082,73.4,6.6,1909 GSM935483: Harvard ChipSeq GM12878 ZZZ3 std source_name=GM12878 || biomat...rd || lab description=Struhl - Harvard University || datatype=ChipSeq || datatype d...erial_provider=Coriell; http://ccr.coriell.org/Sections/Search/Search.aspx?PgId=165&q=GM12878 || lab=Harva

  20. Experiment list: SRX688848 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available d prostate cancer cell line || treatment=vehicle || chip antibody=rabbit anti-ASH... prostate cancer cells, vehicle, ASH2 ChIP || cell line=VCaP || cell type=vertebral metastatic lesion-derive...agnosis=Carcinoma 25750434,89.3,6.2,7152 GSM1489926: vcap ash2l veh; Homo sapiens; ChIP-Seq source_name=VCaP

  1. Development of a systematic observation protocol of physical exposure of the back: a preliminary study.

    Science.gov (United States)

    Tousignant, M; Tougas, G; Rossignol, M; Goulet, L

    2002-04-01

    At present there is no systematic observation protocol for the assessment of the multi-factorial aspects of physical exposure related to the back used within the constraints of occupational epidemiological research. In this context, a new preliminary systematic observation protocol is proposed to assess exposure to physical loading of the back using nine categories of physical risk factors: the SOPE back protocol. The objective of this study was to investigate whether the new protocol can correctly identify the level of exposure related to measured physical loading of the back. The subjects of this closed cohort study were 451 manual workers at a natural gas distribution company. The assessment of exposure was made with the protocol using groups with different job titles. The workers were followed for a 2 yr period to establish the risk of a new occurrence of complete disability related to the back (NOCD back injury) in each job grouping. Based on the median of the total scores derived from the protocol, two levels of exposure were identified (high and low). Taking into account the limitations of this study, the protocol in development may be a good tool to establish two levels of exposure to physical loading of the back in large epidemiological studies of occupational low back pain. Further research is needed to replicate these results with larger samples and to test the reliability and predictive validity of the protocol.

  2. Forecasting forest chip energy production in Finland 2008-2014

    International Nuclear Information System (INIS)

    Linden, Mikael

    2011-01-01

    Energy policy measures aim to increase energy production from forest chips in Finland to 10 TWh by year 2010. However, on the regional level production differences are large, and the regional estimates of the potential base of raw materials for the production of forest chips are heterogeneous. In order to analyse the validity of the above target, two methods are proposed to derive forecasts for region-level energy production from forest chips in Finland in the years 2008-2014. The plant-level data from 2003-2007 gives a starting point for a detailed statistical analysis of present and future region-level forest chip production. Observed 2008 regional levels are above the estimated prediction 95% confidence intervals based on aggregation of plant-level time averages. A simple time trend model with fixed-region effects provides accurate forecasts for the years 2008-2014. Forest chip production forecast confidence intervals cover almost all regions for the 2008 levels and the estimates of potential production levels for 2014. The forecast confidence intervals are also derived with re-sampling methods, i.e. with bootstrap methods, to obtain more reliable results. Results confirm that a general materials shortfall is not expected in the near future for forest chip energy production in Finland.

  3. Laser Soldering and Thermal Cycling Tests of Monolithic Silicon Pixel Chips

    CERN Document Server

    Strand, Frode Sneve

    2015-01-01

    An ALPIDE-1 monolithic silicon pixel sensor prototype has been laser soldered to a flex printed circuit using a novel interconnection technique using lasers. This technique is to be optimised to ensure stable, good quality connections between the sensor chips and the FPCs. To test the long-term stability of the connections, as well as study the effects on hit thresholds and noise in the sensor, it was thermally cycled in a climate chamber 1200 times. The soldered connections showed good qualities like even melting and good adhesion on pad/flex surfaces, and the chip remained in working condition for 1080 cycles. After this, a few connections failed, having cracks in the soldering tin, rendering the chip unusable. Threshold and noise characteristics seemed stable, except for the noise levels of sector 2 in the chip, for 1000 cycles in a temperature interval of "10^{\\circ}" and "50^{\\circ}" C. Still, further testing with wider temperature ranges and more cycles is needed to test the limitations of the chi...

  4. Bioprinting cell-laden matrigel for radioprotection study of liver by pro-drug conversion in a dual-tissue microfluidic chip

    International Nuclear Information System (INIS)

    Snyder, J E; Hamid, Q; Wang, C; Chang, R; Sun, W; Emami, K; Wu, H

    2011-01-01

    The objective of this paper is to introduce a novel cell printing and microfluidic system to serve as a portable ground model for the study of drug conversion and radiation protection of living liver tissue analogs. The system is applied to study behavior in ground models of space stress, particularly radiation. A microfluidic environment is engineered by two cell types to prepare an improved higher fidelity in vitro micro-liver tissue analog. Cell-laden Matrigel printing and microfluidic chips were used to test radiation shielding to liver cells by the pro-drug amifostine. In this work, the sealed microfluidic chip regulates three variables of interest: radiation exposure, anti-radiation drug treatment and single- or dual-tissue culture environments. This application is intended to obtain a scientific understanding of the response of the multi-cellular biological system for long-term manned space exploration, disease models and biosensors.

  5. Bioprinting cell-laden matrigel for radioprotection study of liver by pro-drug conversion in a dual-tissue microfluidic chip

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, J E; Hamid, Q; Wang, C; Chang, R; Sun, W [Department of Mechanical Engineering, Drexel University, Philadelphia, PA 19104 (United States); Emami, K; Wu, H, E-mail: sunwei@drexel.edu, E-mail: weisun@tsinghua.edu.cn [Radiation Biophysics Lab, NASA Johnson Space Center, Houston, TX 77586 (United States)

    2011-09-15

    The objective of this paper is to introduce a novel cell printing and microfluidic system to serve as a portable ground model for the study of drug conversion and radiation protection of living liver tissue analogs. The system is applied to study behavior in ground models of space stress, particularly radiation. A microfluidic environment is engineered by two cell types to prepare an improved higher fidelity in vitro micro-liver tissue analog. Cell-laden Matrigel printing and microfluidic chips were used to test radiation shielding to liver cells by the pro-drug amifostine. In this work, the sealed microfluidic chip regulates three variables of interest: radiation exposure, anti-radiation drug treatment and single- or dual-tissue culture environments. This application is intended to obtain a scientific understanding of the response of the multi-cellular biological system for long-term manned space exploration, disease models and biosensors.

  6. 60 GHz system-on-chip (SoC) with built-in memory and an on-chip antenna

    KAUST Repository

    Ghaffar, Farhan A.

    2014-04-01

    A novel 60 GHz transmitter SoC with an on-chip antenna and integrated memory in CMOS 65 nm technology is presented in this paper. This highly integrated transmitter design can support a data rate of 2 GBPS with a transmission range of 1 m. The transmitter consists of a fundamental frequency 60 GHz PLL which covers the complete ISM band. The modulator following the PLL can support both BPSK and OOK modulation schemes. Both stored data on the integrated memory or directly from an external source can be transmitted. A tapered slot on chip antenna is integrated with the power amplifier to complete the front end of the transmitter design. Size of the complete transmitter with on-chip antenna is only 1.96 mm × 1.96 mm. The core circuits consume less than 100 mW of power. The high data rate capability of the design makes it extremely suitable for bandwidth hungry applications such as unencrypted HD video streaming and transmission.

  7. 60 GHz system-on-chip (SoC) with built-in memory and an on-chip antenna

    KAUST Repository

    Ghaffar, Farhan A.; Arsalan, Muhammad; Cheema, Hammad; Salama, Khaled N.; Shamim, Atif

    2014-01-01

    A novel 60 GHz transmitter SoC with an on-chip antenna and integrated memory in CMOS 65 nm technology is presented in this paper. This highly integrated transmitter design can support a data rate of 2 GBPS with a transmission range of 1 m. The transmitter consists of a fundamental frequency 60 GHz PLL which covers the complete ISM band. The modulator following the PLL can support both BPSK and OOK modulation schemes. Both stored data on the integrated memory or directly from an external source can be transmitted. A tapered slot on chip antenna is integrated with the power amplifier to complete the front end of the transmitter design. Size of the complete transmitter with on-chip antenna is only 1.96 mm × 1.96 mm. The core circuits consume less than 100 mW of power. The high data rate capability of the design makes it extremely suitable for bandwidth hungry applications such as unencrypted HD video streaming and transmission.

  8. Acrylamide mitigation in potato chips by using NaCl

    DEFF Research Database (Denmark)

    Pedreschi, Franco; Risum, Jørgen; Granby, Kit

    2009-01-01

    Acrylamide is known to cause cancer in laboratory animals but there is no direct evidence that this substance causes cancer in humans. In April 2002, Swedish researchers shocked the world when they presented preliminary findings on the presence of acrylamide in fried and baked foods, most notably...... potato chips and French fries, at levels of 30-2300 ppb. The objective of this research was to study the effect of immersing potato slices in a NaCI solution in relation to acrylamide formation in the prepared potato chips. Potato slices (Verdi variety, diameter: 40 mm, width: 2.0 mm) were fried at 170...

  9. Electrochemical Migration on Electronic Chip Resistors in Chloride Environments

    DEFF Research Database (Denmark)

    Minzari, Daniel; Jellesen, Morten Stendahl; Møller, Per

    2009-01-01

    Electrochemical migration behavior of end terminals on ceramic chip resistors (CCRs) was studied using a novel experimental setup in varying sodium chloride concentrations from 0 to 1000 ppm. The chip resistor used for the investigation was 10-kΩ CCR size 0805 with end terminals made of 97Sn3Pb...... rate of the Sn and stability of Sn ions in the solution layer play a significant role in the formation of dendrites, which is controlled by chloride concentration and potential bias. Morphology, composition, and resistance of the dendrites were dependent on chloride concentration and potential....

  10. Radiation effects on the Viking-2 preamplifier-readout chip

    International Nuclear Information System (INIS)

    Fallot-Burghardt, W.; Hawblitzel, C.; Hofmann, W.; Knoepfle, K.T.; Seeger, M.; Brenner, R.; Nygaard, E.; Rudge, A.; Toker, O.; Weilhammer, P.; Yoshioka, K.

    1994-01-01

    We have studied the radiation sensitivity of the Viking-2 VLSI circuit which has been designed for the readout of silicon strip detectors and manufactured at Mietec in 1.5 μm CMOS technology. Both biased and unbiased chips have been irradiated with a 137 Cs γ source up to a total dose of 2 kGy (200 krad) after which all tested chips were still fully functional. We report the characteristic changes of device parameters with dose, including equivalent noise charge for different capacitive loads, and determine transistor threshold shifts and change of mobilities. ((orig.))

  11. Fungal pretreatment of albizia chips for enhanced biogas production by solid-state anaerobic digestion

    Science.gov (United States)

    Albizia biomass is a forestry waste, and holds a great potential in biogas production by solid-state anaerobic digestion (SS-AD). However, low methane yields from albizia chips were observed due to their recalcitrant structure. In this study, albizia chips were pretreated by Ceriporiopsis subvermisp...

  12. Highly expressed loci are vulnerable to misleading ChIP localization of multiple unrelated proteins

    NARCIS (Netherlands)

    Teytelman, L.; Thurtle, D.M.; Rine, J.; van Oudenaarden, A.

    2013-01-01

    Chromatin immunoprecipitation (ChIP) is the gold-standard technique for localizing nuclear proteins in the genome. We used ChIP, in combination with deep sequencing (Seq), to study the genome-wide distribution of the Silent information regulator (Sir) complex in Saccharomyces cerevisiae. We analyzed

  13. Firing with wood chips in heating and cogeneration plants

    International Nuclear Information System (INIS)

    Kofman, P.D.

    1992-01-01

    The document was produced for use as detailed teaching material aimed at spreading information on the use of wood chips as fuel for heating and cogeneration plants. It includes information and articles on wood fuels generally, combustion values, chopping machines, suppliers, occupational health hazards connected with the handling of wood chips, measuring amounts, the selection of types, prices, ash, environmental aspects and information on the establishment of a wood-chip fired district heating plant. (AB)

  14. Runtime adaptive multi-processor system-on-chip: RAMPSoC

    OpenAIRE

    Göhringer, D.; Hübner, M.; Schatz, V.; Becker, J.

    2008-01-01

    Current trends in high performance computing show, that the usage of multiprocessor systems on chip are one approach for the requirements of computing intensive applications. The multiprocessor system on chip (MPSoC) approaches often provide a static and homogeneous infrastructure of networked microprocessor on the chip die. A novel idea in this research area is to introduce the dynamic adaptivity of reconfigurable hardware in order to provide a flexible heterogeneous set of processing elemen...

  15. The Chip-Scale Atomic Clock - Recent Development Progress

    Science.gov (United States)

    2004-09-01

    35th Annual Precise Time and Time Interval (PTTI) Meeting 467 THE CHIP-SCALE ATOMIC CLOCK – RECENT DEVELOPMENT PROGRESS R. Lutwak ...1] R. Lutwak , et al., 2003, “The Chip-Scale Atomic Clock – Coherent Population Trapping vs. Conventional Interrogation,” in

  16. A two-dimensional simulation model for the molded underfill process in flip chip packaging

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Xue Ru; Young, Wen Bin [National Cheng Kung University, Tainan (China)

    2015-07-15

    The flip chip process involves the deposition of solder bumps on the chip surface and their subsequent direct attachment and connection to a substrate. Underfilling traditional flip chip packaging is typically performed following a two-step approach. The first step uses capillary force to fill the gap between the chip and the substrate, and the second step uses epoxy molding compound (EMC) to overmold the package. Unlike traditional flip chip packaging, the molded underfill (MUF) concept uses a single-step approach to simultaneously achieve both underfill and overmold. MUF is a simpler and faster process. In this study, a 2D numerical model is developed to simulate the front movement of EMC flow and the void formation for different geometric parameters. The 2D model simplifies the procedures of geometric modeling and reduces the modeling time for the MUF simulation. Experiments are conducted to verify the prediction results of the model. The effect on void formation for different geometric parameters is investigated using a 2D model.

  17. Micro flow-through PCR in a PMMA chip fabricated by KrF excimer laser.

    Science.gov (United States)

    Yao, Liying; Liu, Baoan; Chen, Tao; Liu, Shibing; Zuo, Tiechuan

    2005-09-01

    As the third PCR technology, micro flow-through PCR chip can amplify DNA specifically in an exponential fashion in vitro. Nowadays many academies in the world have successfully amplified DNA using their own-made flow-through PCR chip. In this paper, the ablation principle of PMMA at 248 nm excimer laser was studied, then a PMMA based flow-through PCR chip with 20 cycles was fabricated by excimer laser at 19 kv and 18 mm/min. The chip was bonded together with another cover chip at 105( composite function)C, 160 N and 20 minutes. In the end, it was integrated with electrical thermal thin films and Pt 100 temperature sensors. The temperature controllers was built standard PID digital temperature controller, the temperature control precision was +/- 0.2( composite function)C. The temperature grads between the three temperature zones were 16.5 and 22.2( composite function)C respectively, the gaps between the temperature zones could realize heat insulation.

  18. Flip-chip bonded optoelectronic integration based on ultrathin silicon (UTSi) CMOS

    Science.gov (United States)

    Hong, Sunkwang; Ho, Tawei; Zhang, Liping; Sawchuk, Alexander A.

    2003-06-01

    We describe the design and test of flip-chip bonded optoelectronic CMOS devices based on Peregrine Semiconductor's 0.5 micron Ultra-Thin Silicon on sapphire (UTSi) technology. The UTSi process eliminates the substrate leakage that typically results in crosstalk and reduces parasitic capacitance to the substrate, providing many benefits compared to bulk silicon CMOS. The low-loss synthetic sapphire substrate is optically transparent and has a coefficient of thermal expansion suitable for flip-chip bonding of vertical cavity surface emitting lasers (VCSELs) and detectors. We have designed two different UTSi CMOS chips. One contains a flip-chip bonded 1 x 4 photodiode array, a receiver array, a double edge triggered D-flip flop-based 2047-pattern pseudo random bit stream (PRBS) generator and a quadrature-phase LC-voltage controlled oscillator (VCO). The other chip contains a flip-chip bonded 1 x 4 VCSEL array, a driver array based on high-speed low-voltage differential signals (LVDS) and a full-balanced differential LC-VCO. Each VCSEL driver and receiver has individual input and bias voltage adjustments. Each UTSi chip is mounted on different printed circuit boards (PCBs) which have holes with about 1 mm radius for optical output and input paths through the sapphire substrate. We discuss preliminary testing of these chips.

  19. Estimate the thermomechanical fatigue life of two flip chip packages

    International Nuclear Information System (INIS)

    Pash, R.A.; Ullah, H.S.; Khan, M.Z.

    2005-01-01

    The continuing demand towards high density and low profile integrated circuit packaging has accelerated the development of flip chip structures as used in direct chip attach (DCA) technology, ball grid array (BOA) and chip scale package (CSP). In such structures the most widely used flip chip interconnects are solder joints. The reliability of flip chip structures largely depends on the reliability of solder joints. In this work solder joint fatigue life prediction for two chip scale packages is carried out. Elasto-plastic deformation behavior of the solder was simulated using ANSYS. Two dimensional plain strain finite element models were developed for each package to numerically compute the stress and total strain of the solder joints under temperature cycling. These stress and strain values are then used to predict the solder joint lifetime through modified Coffin Manson equation. The effect of solder joint's distance from edge of silicon die on life of the package is explored. The solder joint fatigue response is modeled for a typical temperature cycling of -60 to 140 degree C. (author)

  20. Quality wood chips - an alternative to pellets; Alternative zu Pellets. Qualischnitzel

    Energy Technology Data Exchange (ETDEWEB)

    Keel, A.

    2008-07-01

    This article takes a look at a new wood-chip product that features wood-chips that are dryer than traditional ones. The new 'quality chips' are also of a calibrated size and are supplied dust-free. Their low water content permits their use in the same areas as wood pellets, where, especially in summer, low water-content is important. The increasing use of pellets and the growing shortages of clean sawdust and shavings for their production is commented on, as is the use of forestry wastes in pellet production. The new wood-chip product is further discussed as being a direct alternative to pellets. The low 'grey energy' content for tree-felling, hacking, transport and the drying of the chips is quoted as being less than 5% of the energy in the chippings.