WorldWideScience

Sample records for chinese slimming capsules

  1. Chinese Patent Medicine Tongxinluo Capsule for Hypertension: A Systematic Review of Randomised Controlled Trials

    Directory of Open Access Journals (Sweden)

    Jie Wang

    2014-01-01

    Full Text Available Background. This study was intended to evaluate the efficacy and safety of Tongxinluo capsule for hypertension. Search Strategy. We searched the Cochrane Central Register of Controlled Trials (CENTRAL in the Cochrane Library, The PubMed, EMBASE, Chinese Bio-Medical Literature Database (CBM, Chinese National Knowledge Infrastructure (CNKI, Chinese Scientific Journal Database, and Wan-fang Data started from the first of database to October 28, 2013. No language restriction was applied. We included randomized clinical trials testing Tongxinluo capsule against western medicine, Tongxinluo capsule versus placebo, and Tongxinluo capsule combined with western medicine versus western medicine. Study selection, data extraction, quality assessment, and data analyses were conducted according to the Cochrane standards. Results. 25 trials with 1958 participants were included. The methodological quality of the included trials was evaluated as generally low. The blood pressure (BP lowering effect of Tongxinluo capsule plus western medicine was significantly higher than that of western medicine (systolic blood pressure (SBP: −3.87, −5.32 to −2.41, P<0.00001; and diastolic blood pressure (DBP: −2.72, −4.19 to −1.24, P=0.0003. The BP also decreased significantly from baseline with Tongxinluo capsule than placebo (SBP: −9.40, −10.90 to −7.90, P<0.00001; and DBP: −11.80, −12.40 to −11.20, P<0.00001 or western medicine (SBP: −3.90, −4.93 to −2.87, P<0.00001; and DBP: −3.70, −3.83 to −3.57, P<0.00001. 12 trials reported adverse events without details. Conclusions. There is some but weak evidence about the effectiveness of TXL in treating patients with hypertension.

  2. Pharmacokinetic Study of a Diclofenac Sodium Capsule Filled with Enteric-coated Pellets in Healthy Chinese Volunteers by Liquid Chromatography-electrospray Ionization-tandem Mass Spectrometry.

    Science.gov (United States)

    Ma, J-Y; Liu, M; Yang, M; Zhao, H; Tong, Y; Zhang, Y; Deng, M; Liu, H

    2016-05-01

    The pharmacokinetic study of a diclofenac sodium capsule filled with enteric-coated pellets (abbreviated as CAPSULE) in healthy Chinese subjects was evaluated using liquid chromatography-electrospray ionization-tandem mass spectrometry with simple sample preparation. In a cross-over study, 12 healthy male volunteers were given 50 mg CAPSULE and diclofenac sodium enteric-coated tablet (abbreviated as TABLET, used as a control dosage form) at fasting. The Cmax, AUC0-t, and Tmax of CAPSULE were 1.01±0.52 μg/mL, 1.54±0.18 μg·h/mL, and 1.50±1.31 h, respectively. When compared with TABLET, the pharmacokinetic study showed that although this CAPSULE exhibited similar AUC (only 10% lower), it presented lower maximum plasma concentration, faster absorption and shorter time to reach maximum concentration. When compared with the previous study in Germany, obvious variations on Tmax were found in Chinese subjects taking CAPSULE, but not TABLET. The results indicated that individual difference should be paid attention when prescribing CAPSULE to Chinese patients. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Pharmacovigilance: Tiens Slimming Tea Causes Increased Blood ...

    African Journals Online (AJOL)

    ... possible link between the constituents of the slimming tea and increased blood pressure and also provide evidence of other possible harmful effects that may occur with the use of the slimming tea. Keywords: Pharmacovigilance, hypertension, slimming tea. West African Journal of Pharmacology and Drug Research Vol.

  4. [Post-marketing clinical study of traditional Chinese medicine--lessons learned from comprehensive evaluation of Fufang Zaoren capsule].

    Science.gov (United States)

    Qing, Shan; Gao, Lin; Zhang, Li; Jia, Jian-Ping; Liu, Xin-Min; Ji, Shao-Liang; Yang, Xiao-Hui

    2013-11-01

    By comprehensive review and analysis of post-marketing clinical research on the efficacy and safety,we concluded that Fufang Zaoren capsule has certain therapeutic effects for insomnia, although current clinical research design needs improving. The post-marketing clinical studies also showed that it causes several adverse reactions at the recommended doses, such as chills, fever, dizziness, nausea, shortness of breath, chest tightness and palpitations, whereas high doses of Fufang Zaoren capsule can cause delayed extrapyramidal symptoms. Health Canada government website also prompted the L-tetrahydropalmatine in Fufang Zaoren capsule caused liver damage in pregnant women. The authors summarized the risk points, factors and risk control in the clinical use of Fufang Zaoren capsule and also present their perspective on the research status, existing problems and corresponding countermeasures in the post-marketing clinical re-evaluation of traditional Chinese medicine.

  5. Slim hole drilling and testing strategies

    Science.gov (United States)

    Nielson, Dennis L.; Garg, Sabodh K.; Goranson, Colin

    2017-12-01

    The financial and geologic advantages of drilling slim holes instead of large production wells in the early stages of geothermal reservoir assessment has been understood for many years. However, the practice has not been fully embraced by geothermal developers. We believe that the reason for this is that there is a poor understanding of testing and reservoir analysis that can be conducted in slim holes. In addition to reservoir engineering information, coring through the cap rock and into the reservoir provides important data for designing subsequent production well drilling and completion. Core drilling requires significantly less mud volume than conventional rotary drilling, and it is typically not necessary to cure lost circulation zones (LCZ). LCZs should be tested by either production or injection methods as they are encountered. The testing methodologies are similar to those conducted on large-diameter wells; although produced and/or injected fluid volumes are much less. Pressure, temperature and spinner (PTS) surveys in slim holes under static conditions can used to characterize temperature and pressure distribution in the geothermal reservoir. In many cases it is possible to discharge slim holes and obtain fluid samples to delineate the geochemical properties of the reservoir fluid. Also in the latter case, drawdown and buildup data obtained using a downhole pressure tool can be employed to determine formation transmissivity and well properties. Even if it proves difficult to discharge a slim hole, an injection test can be performed to obtain formation transmissivity. Given the discharge (or injection) data from a slimhole, discharge properties of a large-diameter well can be inferred using wellbore modeling. Finally, slim hole data (pressure, temperature, transmissivity, fluid properties) together with reservoir simulation can help predict the ability of the geothermal reservoir to sustain power production.

  6. DOE HIGH-POWER SLIM-HOLE DRILLING SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Dr. William C. Maurer; John H. Cohen; J. Chris Hetmaniak; Curtis Leitko

    1999-09-01

    This project used a systems approach to improve slim-hole drilling performance. A high power mud motor, having a double-length power section, and hybrid PDC/TSP drill bit were developed to deliver maximum horsepower to the rock while providing a long life down hole. This high-power slim-hole drilling system drills much faster than conventional slim-hole motor and bit combinations and holds significant potential to reduce slim-hole drilling costs. The oil and gas industries have been faced with downward price pressures since the 1980s. These pressures are not expected to be relieved in the near future. To maintain profitability, companies have had to find ways to reduce the costs of producing oil and gas. Drilling is one of the more costly operations in the production process. One method to reduce costs of drilling is to use smaller more mobile equipment. Slim holes have been drilled in the past using this principle. These wells can save money not only from the use of smaller drilling equipment, but also from reduced tubular costs. Stepping down even one casing size results in significant savings. However, slim holes have not found wide spread use for three reasons. First, until recently, the price of oil has been high so there were no forces to move the industry in this direction. Second, small roller bits and motors were not very reliable and they drilled slowly, removing much of the economic benefit. The third and final reason was the misconception that large holes were needed everywhere to deliver the desired production. Several factors have changed that will encourage the use of slim holes. The industry now favors any method of reducing the costs of producing oil and gas. In addition, the industry now understands that large holes are not always needed. Gas, in particular, can have high production rates in smaller holes. New materials now make it possible to manufacture improved bits and motors that drill for long periods at high rates. All that remains is to

  7. Prevention of Type 2 Diabetes with the Chinese Herbal Medicine Tianqi Capsule: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Pang, Bing; Zhang, Ying; Liu, Jing; He, Li-Sha; Zheng, Yu-Jiao; Lian, Feng-Mei; Tong, Xiao-Lin

    2017-12-01

    Prevention of the rapid growth in incidence of type 2 diabetes (T2DM) is a big challenge for clinicians. In China, many trials have indicated that Tianqi capsule, which contains several Chinese herbal medicines as part of a large healing system called traditional Chinese medicine, could decrease the incidence of T2DM. The review assessed the effectiveness of Tianqi capsule in prevention of T2DM. Seven electronic databases were searched to identify eligible trials published from the inception of the databases up until May 1, 2017. Randomized controlled trials (RCTs) of Tianqi capsule for impaired glucose tolerance (IGT) were included. Data extraction and quality assessment were performed according to the Cochrane review standards. A random or a fixed effect model was used to analyze outcomes which were expressed as risk ratios (RRs) or mean differences (MD), and I 2 statistics were used to assess heterogeneity. Six trials were identified that included 1027 subjects. Meta-analysis showed that subjects who received Tianqi capsule plus lifestyle modification (LM) were less likely to progress to T2DM compared to controls (RR 0.55, 95% CI 0.44-0.68). Subjects who received Tianqi capsule plus LM were more likely to have glucose return to normal compared to controls (RR 0.69; 95% CI 0.62-0.78); and they had reduced fasting plasma glucose (FBG) (MD - 0.35; 95% CI - 0.55 to - 0.16) and 2-h plasma glucose (2 h PG) (MD - 1.04; 95% CI - 1.75 to - 0.32). There was no statistical difference between the two groups for IGT stabilized incidence (RR 0.89; 95% CI 0.71-1.12). No obvious adverse events occurred. In patients with IGT, Tianqi capsule reduced the risk of progression to T2DM and increased the possibility of regression toward normoglycemia. As a result of the limited number of RCTs and the methodological drawbacks of the included studies, the results should be interpreted with caution.

  8. Efficacy of Chinese patent medicine Tian Gui Capsule in patients with polycystic ovary syndrome: a randomized controlled trial.

    Science.gov (United States)

    Kuek, Susuana; Wang, Wen-jun; Gui, Sui-qi

    2011-09-01

    Polycystic ovary syndrome (PCOS) is a complex hormonal disorder and one of the most common reproductive endocrinology abnormalities in women. Recently, many studies have been conducted assessing Chinese herbal medicine as an alternative treatment for women with PCOS, it is, therefore, worthwhile to analyze and observe the curative effects of traditional Chinese medicine treatment in PCOS. To evaluate the efficacy of the Chinese patent medicine Tian Gui Capsule, in women with PCOS and compare its effects with metformin and ethinyl estradiol plus cyproterone acetate (Diane-35). A total of 47 PCOS outpatients from the Obstetrics and Gynecology Hospital of Fudan University were randomly divided into 3 groups. Patients in group A (n=19) were given Tian Gui Capsule, patients in group B (n=17) were given metformin, and patients in group C (n=11) were given Diane-35. The 3 groups of patients were treated for 3 months. Serum testosterone (T), sex hormone binding globulin (SHBG) and dehydroepiandrosterone sulfate (DHEA-S) levels, free androgen index (FAI), fasting blood glucose (FPG), fasting insulin (FINS), homeostasis model assessment of insulin resistance (HOMA-IR), insulin sensitive index (ISI) and left and right ovary volumes of the 3 groups were evaluated before and after treatment . After 3 months of treatment, when compared with before treatment data, group A patients showed decreased serum T and SHBG levels, FAI, FINS, and left and right ovary volumes (P<0.05), and increased serum DHEA-S (P<0.05), while the FPG level showed no significant change. Although the level of serum T and FINS among the 3 groups after the treatment were similar, group A demonstrated better results than group B in reducing the FAI and increasing the serum SHBG, but less significant results than group C besides, group B was the only group showed improved insulin sensitivity. Although the level of FPG of the 3 groups after treatment were similar, group C had the most increased FPG. The effects

  9. SLiM 2: Flexible, Interactive Forward Genetic Simulations.

    Science.gov (United States)

    Haller, Benjamin C; Messer, Philipp W

    2017-01-01

    Modern population genomic datasets hold immense promise for revealing the evolutionary processes operating in natural populations, but a crucial prerequisite for this goal is the ability to model realistic evolutionary scenarios and predict their expected patterns in genomic data. To that end, we present SLiM 2: an evolutionary simulation framework that combines a powerful, fast engine for forward population genetic simulations with the capability of modeling a wide variety of complex evolutionary scenarios. SLiM achieves this flexibility through scriptability, which provides control over most aspects of the simulated evolutionary scenarios with a simple R-like scripting language called Eidos. An example SLiM simulation is presented to illustrate the power of this approach. SLiM 2 also includes a graphical user interface for simulation construction, interactive runtime control, and dynamic visualization of simulation output, facilitating easy and fast model development with quick prototyping and visual debugging. We conclude with a performance comparison between SLiM and two other popular forward genetic simulation packages. © The Author 2016. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. [Exploring the clinical characters of Shugan Jieyu capsule through text mining].

    Science.gov (United States)

    Pu, Zheng-Ping; Xia, Jiang-Ming; Xie, Wei; He, Jin-Cai

    2017-09-01

    The study was main to explore the clinical characters of Shugan Jieyu capsule through text mining. The data sets of Shugan Jieyu capsule were downloaded from CMCC database by the method of literature retrieved from May 2009 to Jan 2016. Rules of Chinese medical patterns, diseases, symptoms and combination treatment were mined out by data slicing algorithm, and they were demonstrated in frequency tables and two dimension based network. Then totally 190 literature were recruited. The outcomess suggested that SC was most frequently correlated with liver Qi stagnation. Primary depression, depression due to brain disease, concomitant depression followed by physical diseases, concomitant depression followed by schizophrenia and functional dyspepsia were main diseases treated by Shugan Jieyu capsule. Symptoms like low mood, psychic anxiety, somatic anxiety and dysfunction of automatic nerve were mainy relieved bv Shugan Jieyu capsule.For combination treatment. Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. The research suggested that syndrome types and mining results of Shugan Jieyu capsule were almost the same as its instructions. Syndrome of malnutrition of heart spirit was the potential Chinese medical pattern of Shugan Jieyu capsule. Primary comorbid anxiety and depression, concomitant comorbid anxiety and depression followed by physical diseases, and postpartum depression were potential diseases treated by Shugan Jieyu capsule.For combination treatment, Shugan Jieyu capsule was most commonly used with paroxetine, sertraline and fluoxetine. Copyright© by the Chinese Pharmaceutical Association.

  11. Effects of slim holes on hydrothermal exploration costs

    International Nuclear Information System (INIS)

    Entingh, D.; Petty, S.

    1992-01-01

    This paper estimates hydrothermal exploration costs and the effects that using slim holes could have on those costs using a computer code developed for the US-DOE. The primary goal of exploration is to generate decision driving information about particular geothermal reservoirs. Compared to today's exploration strategies, the main effect of using slim holes would be to reduce the cost of exploration by about 40 percent. Slim hole exploration does not reduce the overall cost of electricity by much; however, the cost burden is shifted later in the project when outside financing is more likely. The reduced costs of slim holes may also encourage developers to drill more holes that better characterize the reservoir, thus reducing long term reservoir risk. The cost of power could then be cut as much as six percent and project financial risks related to reservoir uncertainties could be reduced by up to one quarter. In order to realize these improvements, the amount of reservoir information recovered from small diameter bore holes needs to be significantly increased

  12. SLIM-MAUD - a computer based technique for human reliability assessment

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1985-01-01

    The Success Likelihood Index Methodology (SLIM) is a widely applicable technique which can be used to assess human error probabilities in both proceduralized and cognitive tasks (i.e. those involving decision making, problem solving, etc.). It assumes that expert assessors are able to evaluate the relative importance (or weights) of different factors called Performance Shaping Factors (PSFs), in determining the likelihood of error for the situations being assessed. Typical PSFs are the extent to which good procedures are available, operators are adequately trained, the man-machine interface is well designed, etc. If numerical ratings are made of the PSFs for the specific tasks being evaluated, these can be combined with the weights to give a numerical index, called the Success Likelihood Index (SLI). The SLI represents, in numerical form, the overall assessment of the experts of the likelihood of task success. The SLI can be subsequently transformed to a corresponding human error probability (HEP) estimate. The latest form of the SLIM technique is implemented using a microcomputer based system called MAUD (Multi-Attribute Utility Decomposition), the resulting technique being called SLIM-MAUD. A detailed description of the SLIM-MAUD technique and case studies of applications are available. An illustrative example of the application of SLIM-MAUD in probabilistic risk assessment is given

  13. Measurement of the volume of internal capsule in healthy Chinese adults of the Han nationality on the high-resolution MRI

    International Nuclear Information System (INIS)

    Qin Yuan; Guo Yulin; Zhu Kai; Lai Yanbo; Ma Shuai; Chen Nan; Wang Xing; Li Kuncheng; Zhu Yan; Chen Lin

    2012-01-01

    Objective: To explore the normal range of the volume of internal capsules in Chinese adults of the Han nationality and its relationship with age, body habitus, and craniocerebral volume. Methods: One thousand healthy volunteers (age range =18 to 80 years) were divided into 5 groups according to their age; Group A (18 to 30 years old), group B (31 to 40 years), group C (41 to 50 years), group D (51 to 60 years), and group E (61 to 80 years). Each group consisted of 100 males and 100 females. MR imaging was performed in all of the volunteers using T 1 weighted three-dimensional magnetization prepared rapid acquisition gradient echo sequence. After three dimension data reconstruction, the volumes of bilateral internal capsules were manually measured. The volumes of bilateral internal capsules were compared by paired sample t test. The internal capsule volumes were compared between male and female by independent sample t test, and the differences among 5 age groups were compared by one-way ANOVA. The relationship between the volumes of internal capsule and age, body habitus or cerebral volume were analyzed using bivariate correlation. Results: The left and right internal capsule volumes were (2809 ± 393) and (2677 ± 343 ) mm 3 respectively. The left internal capsule volumes were significantly larger than that of right (t=12.078, P<0.05). The left and right side of internal capsule volumes in male were (2863 ± 396) and (2744 ±358) mm 3 respectively, and (2754 ±385) and (2609 ±314) mm 3 in female. The left and right internal capsule volumes were larger in males than in female (t=1.982, 2.851; P<0.05). The left internal capsule volume of the 5 age groups were (3273 ± 361), (2943 ± 299), (2777 ± 255), (2607 ± 199), (2444 ±213) mm 3 , and the right were (2993 ± 361), (2814 ± 270), (2682 ± 239), (2543 ± 219), (2351 ±210) mm 3 . There were significant differences among 5 age groups between left and right internal capsule volume (F=55.244, 34.493; P<0

  14. The development of the nasal capsule of the silver carp ...

    African Journals Online (AJOL)

    The development of the nasal capsule, including the procartilaginous as well as some mesenchymatous developmental stages, is described in the chinese silver carp,. Hypophthalmichthys molitrix (VaL). In the nasal capsule a primitive feature, namely the presence of a complete paraphysial bridge was observed.

  15. Development of slim-maud: a multi-attribute utility approach to human reliability evaluation

    International Nuclear Information System (INIS)

    Embrey, D.E.

    1984-01-01

    This paper describes further work on the Success Likelihood Index Methodology (SLIM), a procedure for quantitatively evaluating human reliability in nuclear power plants and other systems. SLIM was originally developed by Human Reliability Associates during an earlier contract with Brookhaven National Laboratory (BNL). A further development of SLIM, SLIM-MAUD (Multi-Attribute Utility Decomposition) is also described. This is an extension of the original approach using an interactive, computer-based system. All of the work described in this report was supported by the Human Factors and Safeguards Branch of the US Nuclear Regulatory Commission

  16. Slim Battery Modelling Features

    Science.gov (United States)

    Borthomieu, Y.; Prevot, D.

    2011-10-01

    Saft has developed a life prediction model for VES and MPS cells and batteries. The Saft Li-ion Model (SLIM) is a macroscopic electrochemical model based on energy (global at cell level). The main purpose is to predict the battery performances during the life for GEO, MEO and LEO missions. This model is based on electrochemical characteristics such as Energy, Capacity, EMF, Internal resistance, end of charge voltage. It uses fading and calendar law effects on energy and internal impedance vs. time, temperature, End of Charge voltage. Based on the mission profile, satellite power system characteristics, the model proposes the various battery configurations. For each configuration, the model gives the battery performances using mission figures and profiles: power, duration, DOD, end of charge voltages, temperatures during eclipses and solstices, thermal dissipations and cell failures. For the GEO/MEO missions, eclipse and solstice periods can include specific profile such as plasmic propulsion fires and specific balancing operations. For LEO missions, the model is able to simulate high power peaks to predict radar pulses. Saft's main customers have been using the SLIM model available in house for two years. The purpose is to have the satellite builder power engineers able to perform by themselves in the battery pre-dimensioning activities their own battery simulations. The simulations can be shared with Saft engineers to refine the power system designs. This model has been correlated with existing life and calendar tests performed on all the VES and MPS cells. In comparing with more than 10 year lasting life tests, the accuracy of the model from a voltage point of view is less than 10 mV at end Of Life. In addition, thethe comparison with in-orbit data has been also done. b This paper will present the main features of the SLIM software and outputs comparison with real life tests. b0

  17. Modeling a Million-Node Slim Fly Network Using Parallel Discrete-Event Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, Noah; Carothers, Christopher; Mubarak, Misbah; Ross, Robert; Carns, Philip

    2016-05-15

    As supercomputers close in on exascale performance, the increased number of processors and processing power translates to an increased demand on the underlying network interconnect. The Slim Fly network topology, a new lowdiameter and low-latency interconnection network, is gaining interest as one possible solution for next-generation supercomputing interconnect systems. In this paper, we present a high-fidelity Slim Fly it-level model leveraging the Rensselaer Optimistic Simulation System (ROSS) and Co-Design of Exascale Storage (CODES) frameworks. We validate our Slim Fly model with the Kathareios et al. Slim Fly model results provided at moderately sized network scales. We further scale the model size up to n unprecedented 1 million compute nodes; and through visualization of network simulation metrics such as link bandwidth, packet latency, and port occupancy, we get an insight into the network behavior at the million-node scale. We also show linear strong scaling of the Slim Fly model on an Intel cluster achieving a peak event rate of 36 million events per second using 128 MPI tasks to process 7 billion events. Detailed analysis of the underlying discrete-event simulation performance shows that a million-node Slim Fly model simulation can execute in 198 seconds on the Intel cluster.

  18. Fitness Promotion for Adolescent Girls: The Impact and Effectiveness of Promotional Material which Emphasizes the Slim Ideal.

    Science.gov (United States)

    Shaw, Susan M.; Kemeny, Lidia

    1989-01-01

    Looked at techniques for promoting fitness participation among adolescent girls, in particular those which emphasize the slim ideal. Relative effectiveness of posters using different models (slim, average, overweight) and different messages (slimness, activity, health) was tested using 627 female high school students. Found slim model to be most…

  19. Study of Reaction Forces in a Single Sided Linear Induction Motor (SLIM)

    Science.gov (United States)

    1974-01-01

    SLIM reaction forces were measured on a laboratory model having aluminum and aluminum-iron secondaries and the results were correlated with the theoretical forces derived for different idealized SLIM models. The first part of the report discusses wav...

  20. Chinese medicinal formula Fufang Xueshuantong capsule could inhibit the activity of angiotensin converting enzyme

    Science.gov (United States)

    Sheng, Shujing; Wang, Yonggang; Long, Chaofeng; Su, Weiwei; Rong, Xia

    2014-01-01

    Fufang Xueshuantong (FXST) capsule, a Chinese medicinal formula composed of four herbals – Panax notoginseng, Radix Astragali, Radix Salvia Miltiorrhizae and Radix Scrophulariaceae, has been used to treat cardiovascular diseases for many years, but the pharmacological mechanisms underlying its effects has not been clarified. This study investigates if a connection between FXST and angiotensin converting enzyme (ACE) might be an explanation for its pharmacological effects. ACE inhibition assay was performed on FXST capsule, 50% ethanol extracts from the four herbals and three selected saponins most abundant in P. notoginseng (Ginsenoside Rg1, Ginsenoside Rb1 and Notoginsenoside R1) using a biochemical test. Reversed-phase high-performance liquid chromatography of liberated hippuric acid from the ACE assay was conducted to determine the inhibitory effect. As a result, FXST and extracts from P. notoginseng showed a significant and dose-dependent inhibition on ACE activity with the IC50 values of 115 μg/ml and 179 μg/ml, respectively. But extracts from the other three herbals and the three selected saponins had no significant effect on ACE inhibition. Compared to other reported plant extracts, FXST could be considered as an effective ACE inhibitor. The inhibition of ACE activity supports the traditional use of FXST on blood circulation and the inhibitory property of FXST is mainly caused by P. notoginseng. PMID:26019516

  1. Experimental Study on the Airside Performance of Aluminum Heat Exchangers Having Slim Louver Fins

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Nae Hyun [Incheon Nat’l Univ., Incheon (Korea, Republic of); Cho, Honggi [Samsung Electronics Daejeon, Suwon (Korea, Republic of)

    2017-09-15

    Recent trends in slim air conditioners require heat exchangers of reduced flow depth. In this study, slim louver fin geometry was obtained using predictive correlations. The deduced geometry yielded 10 mm flow depth, 0.9 mm louver pitch, and 35° louver angle. Samples were made and tests were conducted. The new slim sample yielded 36% higher j factor and 2.3% higher f factor compared with those of the standard sample. This implies that 26% reduction of heat exchanger volume was possible by reducing the flow depth. In addition, the j/f1/3 of the slim sample was 55% larger than that of the standard sample. Furthermore, the results are compared with predictions made using existing correlations.

  2. Experimental Study on the Airside Performance of Aluminum Heat Exchangers Having Slim Louver Fins

    International Nuclear Information System (INIS)

    Kim, Nae Hyun; Cho, Honggi

    2017-01-01

    Recent trends in slim air conditioners require heat exchangers of reduced flow depth. In this study, slim louver fin geometry was obtained using predictive correlations. The deduced geometry yielded 10 mm flow depth, 0.9 mm louver pitch, and 35° louver angle. Samples were made and tests were conducted. The new slim sample yielded 36% higher j factor and 2.3% higher f factor compared with those of the standard sample. This implies that 26% reduction of heat exchanger volume was possible by reducing the flow depth. In addition, the j/f1/3 of the slim sample was 55% larger than that of the standard sample. Furthermore, the results are compared with predictions made using existing correlations.

  3. Active Damping Control Methods for Three-Phase Slim DC-link Drive System

    DEFF Research Database (Denmark)

    Yang, Feng; Wang, Dong; Blaabjerg, Frede

    2017-01-01

    for stabilizing such slim dc-link drives together with the benefit of low cost and high flexibility. This paper gives an overview of the state-of-the-art active damping methods for the three-phase slim dc-link drive. The main pros and cons of each method are identified. The theoretical comparison is validated...

  4. SLIMS--a user-friendly sample operations and inventory management system for genotyping labs.

    Science.gov (United States)

    Van Rossum, Thea; Tripp, Ben; Daley, Denise

    2010-07-15

    We present the Sample-based Laboratory Information Management System (SLIMS), a powerful and user-friendly open source web application that provides all members of a laboratory with an interface to view, edit and create sample information. SLIMS aims to simplify common laboratory tasks with tools such as a user-friendly shopping cart for subjects, samples and containers that easily generates reports, shareable lists and plate designs for genotyping. Further key features include customizable data views, database change-logging and dynamically filled pre-formatted reports. Along with being feature-rich, SLIMS' power comes from being able to handle longitudinal data from multiple time-points and biological sources. This type of data is increasingly common from studies searching for susceptibility genes for common complex diseases that collect thousands of samples generating millions of genotypes and overwhelming amounts of data. LIMSs provide an efficient way to deal with this data while increasing accessibility and reducing laboratory errors; however, professional LIMS are often too costly to be practical. SLIMS gives labs a feasible alternative that is easily accessible, user-centrically designed and feature-rich. To facilitate system customization, and utilization for other groups, manuals have been written for users and developers. Documentation, source code and manuals are available at http://genapha.icapture.ubc.ca/SLIMS/index.jsp. SLIMS was developed using Java 1.6.0, JSPs, Hibernate 3.3.1.GA, DB2 and mySQL, Apache Tomcat 6.0.18, NetBeans IDE 6.5, Jasper Reports 3.5.1 and JasperSoft's iReport 3.5.1.

  5. Slim belt induced morphea-Price paid for a slimmer look

    Directory of Open Access Journals (Sweden)

    Tasleem Arif

    2015-07-01

    Full Text Available Morphea, also known as localized scleroderma, encompasses a group of distinct conditions characterized by sclerosis of the skin and the underlying tissues. Many triggering factors have been implicated in the development of morphea like trauma, immobilization, bacille Calmette–Guérin (BCG vaccination, injections of vitamin K, mechanical compression from clothing, etc. but slim belt as a cause of morphea has not been previously reported to the best of our knowledge. We report a 28 year old married obese woman who developed a shiny brownish indurated plaque over the abdomen after three months of use of a slim belt for her obesity. Skin biopsy was consistent with the diagnosis of morphea. She was prescribed topical tacrolimus 0.1% ointment and improved with course of time. The present case illustrates the first description of morphea as a result of use of slim belt which has not been previously reported in the literature.

  6. Erythema multiforme-like eruption from a slimming drug preparation cutaneous adverse drug reaction

    Directory of Open Access Journals (Sweden)

    Linda Tognetti

    2011-01-01

    Full Text Available We report a case of a 34-year-old woman presenting with an erythema multiforme (EM-like eruption. Lesions developed after a 12-day treatment with a slimming drug preparation (food integrator with thermogenic activity and a herbal remedy (pilosella tincture. Serological investigations excluded viral or bacterial infections. Patch testing with galenic preparations of both drugs demonstrated sensitization to the slimming drug preparation. According to literature reports and immune-chemical properties, those components that are likely to have triggered the skin eruption are clorazepate dipotassium and theobromine. Their interaction with other two constituents such as pseudoephedrine hydrochloride and dehydrocholic acid may have caused the adverse reaction by means of a summation effect. There are no reports specifically about EM caused by a slimming drug preparation and no studies have identified thermogenic pills as cause of EM/EM-like eruption. Weight-loss compounds in slimming preparations should be kept in mind as a possible cause of drug-induced EM-like eruption.

  7. Fire resistance of slim floor beams

    NARCIS (Netherlands)

    Fellinger, J.H.H.; Twilt, L.

    1996-01-01

    Slim floor beams support decks on a wide plate welded on the lower flange of an 1- shaped beam. The air gap between the plate and the lower flange increases the fire resistance of the beam. A Finite Element Method (FEM) model, validated with three fire tests, is used to set up simple calculation

  8. KONTRIBUSI MODAL SOSIAL DALAM PENGEMBANGAN OTOMASI PERPUSTAKAAN: STUDI KASUS KOMUNITAS SLiMS (SENAYAN LIBRARY MANAGEMENT SYSTEM YOGYAKARTA

    Directory of Open Access Journals (Sweden)

    Yanuar Yoga Prasetyawan

    2016-11-01

    Full Text Available Today the implementation of information technology in libraries has become a basic need to organize the information, not least in Indonesia. Lack of economic capital (fund and intellectual capital (human resources that have IT educational background cause many library in Indonesia can not be able to buy or self develop the information technology. However SLiMS attend like a panacea, which capable of treating and eliminating the limitations of most libraries in Indonesia. SLiMS is an open source software for the Library Management that can be downloaded and implemented for free. In addition Slims rarely have the power owned by a software (information systems that is a SLiMS User Community. In Indonesia, SLiMS User Community has mushrooming in various regions across Indonesia, one of them in Yogyakarta. Growth and development of SLiMS User Community in Yogyakarta is a manifestation of social capital for the library with lack of information technology implementation. The purpose of this study is to reveal the values and norms are upheld by the Yogyakarta SLiMS User Community that foster social capital which drives community activities as an agent who eliminate the lack of economic capital and intellectual capital that suffered by many libraries in Indonesia. The method used is qualitative method with phenomenological approach. The results showed that the values and norms are upheld together by the Yogyakarta SLiMS User Community is becoming a agent of change of the library conditions in Indonesia, to contribute the automation development in Indonesia. That value and norms are expressed through the sinau bareng. Through sinau bareng, they were learning together to implement SLiMS. Sinau bareng was held each month by a Yogyakarta SLiMS User Community. it became the antidote the lack of libraries. So it will bring justice for all types of libraries to have the right to fulfi ll their basic needs of implementing information technology as library

  9. Shuangshen Ningxin Capsule, a Traditional Chinese Medicinal Preparation, Alleviates Myocardial Ischemia through Autophagy Regulation

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2015-01-01

    Full Text Available Shuangshen Ningxin capsule (SSNX, a modern Chinese formula, has been used to treat cardiovascular diseases in Eastern Asia. Our study focuses on the autophagy regulation of SSNX against coronary artery injuries. Myocardial infarction model was established in Chinese miniswines (CMS by coronary artery balloon injury. SSNX was administered to the CMS for 8 weeks with 4 mg/kg or 16 mg/kg. Myocardial cells were incubated with 20% SSNX medicated serum for 2 hours. Assays were performed to detect the effects of SSNX on (i coronary artery diameter by angiography, (ii hemodynamics by noninvasive hemodynamic monitoring system, (iii plaque burden and plaque volume by intravenous ultrasound (iv coronary artery histology by H&E staining, (v autophagosome by transmission electron microscopy, (vi lactate dehydrogenase (LDH leakage, and (vii Beclin-1 and LC3-I/II expressions by Western blot. The results showed that CMS treated with SSNX exhibited the correction for the disturbed cardiac hemodynamics, increase of coronary artery diameter, reduction of high plaque burden and plaque volume, and decrease of LDH. The inhibitory effect of SSNX on CMS autophagy was demonstrated by the reduction of autophagosome and the downregulation of beclin-1 and LC3-I/II. SSNX may protect coronary artery and increase the stability of plaque through the suppression of myocardial cellular autophagy, which suggests the potentially therapeutic effect of SSNX on ischemic cardiovascular disease.

  10. Psychosis associated with usage of herbal slimming products adulterated with sibutramine: a case series.

    Science.gov (United States)

    Chen, Sammy P L; Tang, Magdalene H Y; Ng, Sau Wah; Poon, Wing Tat; Chan, Albert Y W; Mak, Tony W L

    2010-10-01

    Sibutramine, or its structurally related analogs, is often found as an adulterant in proprietary herbal slimming products in Hong Kong. A few solitary case reports of sibutramine-associated psychosis have been published since 2000. As the only tertiary referral center for clinical toxicology analysis in Hong Kong, we noticed that psychosis was an unusually common feature in patients taking "herbal slimming products" adulterated with sibutramine or its structurally related analogs over the past 5 years. To examine the association between psychosis and the use of sibutramine-adulterated herbal products, in an attempt to elucidate this possible adverse drug reaction. This retrospective study reviewed all cases hospitalized with psychotic symptoms confirmed to have used herbal slimming products adulterated with sibutramine, or its analogs, between January 2004 and October 2009. The cases' clinical features, outcome, drug history, and analytical findings of the offending slimming products were studied. Results. Among the 16 confirmed cases, 15 (94%) were female; the median age was 19 years (range: 15-47). Auditory hallucination was documented in 10 (63%), visual hallucination in 6 (38%), persecutory ideas in 6 (38%), delusions in 4 (25%), and suicidal ideation in 2 (13%). For 20 "herbal" slimming products analyzed, 16 were found to have been adulterated with sibutramine, 2 with N-desmethyl-sibutramine, and 1 with N-bisdesmethyl-sibutramine. Other concomitant adulterants were also found and included phenolphthalein in 9, fenfluramine, mazindol, animal thyroid tissue in 2, hydrochlorothiazide and spironolactone in 1. Eight patients disclosed the source of the products: four through the Internet, one obtained over-the-counter locally, with three acquired outside Hong Kong. Slimming products claimed "herbal" in origin could often be adulterated with sibutramine and other Western medications. We observed an association between the use of these products and psychotic features

  11. Relative bioequivalence evaluation of two oral atomoxetine hydrochloride capsules: a single dose, randomized, open-label, 2-period crossover study in healthy Chinese volunteers under fasting conditions.

    Science.gov (United States)

    Shang, D-W; Guo, W; Zhou, F-C; Wang, X-P; Li, A-N; Zhang, L; Li, W-B; Lu, W; Wang, C-Y

    2013-11-01

    To evaluate the bioequivalence of a new formulation of atomoxetine hydrochloride (CAS 82248-59-7) capsules (test) and an available branded capsules (reference) after administration of a single 40 mg dose, randomized, open-label, 2-period crossover study was conducted in 22 healthy male Chinese subjects with a 1-week wash-out period. This study was designed for/the Honglin Pharmaceutical Co. Ltd and contracted to be done by the Beijing Anding Hospital in order to satisfy Chinese regulatory requirements to allow marketing of this generic product and performed according to the criteria of SFDA. Blood samples were collected before and 0.25, 0.5, 1, 1.5, 2, 3, 4, 6, 9, 12, 16 and 24 h after drug administration. Plasma concentrations were determined by high-performance liquid chromatography (HPLC) with UV detection. A non-compartmental method was used to calculate the pharmacokinetic parameters and evaluate bioequivalence of the 2 formulations. The 90% confidence interval (CI) of the ratios (test/reference) of atomoxetine for AUC0-24, AUC0-∞ and Cmax were 100.9% (93.6-108.8%), 103.1% (95.1-111.7%) and 105.2% (92.8-119.4%), respectively, which fell within the interval of 80-125% and 75-133%. No clinically significant changes or abnormalities were noted in laboratory data and vital signs. From these results it can be concluded that the test formulation of atomoxetine capsules met the regulatory criterion for bioequivalence to the reference formulation. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Input Harmonic Analysis on the Slim DC-Link Drive Using Harmonic State Space Model

    DEFF Research Database (Denmark)

    Yang, Feng; Kwon, Jun Bum; Wang, Xiongfei

    2017-01-01

    The harmonic performance of the slim dc-link adjustable speed drives has shown good performance in some studies but poor in some others. The contradiction indicates that a feasible theoretical analysis is still lacking to characterize the harmonic distortion for the slim dc-link drive. Considerin...... results of the slim dc-link drive, loaded up to 2.0 kW, are presented to validate the theoretical analysis....... variation according to the switching instant, the harmonics at the steady-state condition, as well as the coupling between the multiple harmonic impedances. By using this model, the impaction on the harmonics performance by the film capacitor and the grid inductance is derived. Simulation and experimental...

  13. Improving fluorescence diagnosis of cancer by SLIM

    Science.gov (United States)

    Rück, Angelika; Dolp, Frank; Kinzler, Ingrid; Hauser, Carmen; Scalfi-Happ, Claudia

    2006-02-01

    Although during the last years, significant progress was made in cancer diagnosis, using either intrinsic or specially designed fluorophores, still problems exist, due to difficulties in spectral separation of highly overlapping probes or in lack of specificity. Many of the problems could be circumvented by focusing on time-resolved methods. In combination with spectral resolved detection (spectral fluorescence lifetime imaging, SLIM) highly sophisticated fluorescence lifetime imaging can be performed which might improve specificity of cell diagnosis. To record lifetime images (τ-mapping) with spectral resolution a setup was realized consisting of a laser scanning microscope equipped with a 16 channel array for time-correlated single photon counting (TCSPC) and a spectrograph in front of the array. A Ti:Saphir laser can be used for excitation or alternatively ps diode lasers. With this system the time- and spectral-resolved fluorescence characteristics of different fluorophores were investigated in solution and in cell culture. As an example, not only the mitochondria staining dye rhodamine 123 could be easily distinguished from DAPI, which intercalates into nucleic acids, but also different binding sites of DAPI. This was proved by the appearance of different lifetime components within different spectral channels. Another example is Photofrin, a photosensitizer which is approved for bladder cancer and for palliative lung and esophageal cancer in 20 countries, including the United States, Canada and many European countries. Photofrin is a complex mixture of different monomeric and aggregated porphyrins. The phototoxic efficiency during photodynamic therapy (PDT) seems to be correlated with the relative amounts of monomers and aggregates. With SLIM different lifetimes could be attributed to various, spectrally highly overlapping compounds. In addition, a detailed analysis of the autofluorescence by SLIM could explain changes of mitochondrial metabolism during

  14. Identification of the chemical constituents of Chinese medicine Yi-Xin-Shu capsule by molecular feature orientated precursor ion selection and tandem mass spectrometry structure elucidation.

    Science.gov (United States)

    Wang, Hong-ping; Chen, Chang; Liu, Yan; Yang, Hong-Jun; Wu, Hong-Wei; Xiao, Hong-Bin

    2015-11-01

    The incomplete identification of the chemical components of traditional Chinese medicinal formula has been one of the bottlenecks in the modernization of traditional Chinese medicine. Tandem mass spectrometry has been widely used for the identification of chemical substances. Current automatic tandem mass spectrometry acquisition, where precursor ions were selected according to their signal intensity, encounters a drawback in chemical substances identification when samples contain many overlapping signals. Compounds in minor or trace amounts could not be identified because most tandem mass spectrometry information was lost. Herein, a molecular feature orientated precursor ion selection and tandem mass spectrometry structure elucidation method for complex Chinese medicine chemical constituent analysis was developed. The precursor ions were selected according to their two-dimensional characteristics of retention times and mass-to-charge ratio ranges from herbal compounds, so that all precursor ions from herbal compounds were included and more minor chemical constituents in Chinese medicine were identified. Compared to the conventional automatic tandem mass spectrometry setups, the approach is novel and can overcome the drawback for chemical substances identification. As an example, 276 compounds from the Chinese Medicine of Yi-Xin-Shu capsule were identified. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. IMPLANT-ASSOCIATED PATHOLOGY: AN ALGORITHM FOR IDENTIFYING PARTICLES IN HISTOPATHOLOGIC SYNOVIALIS/SLIM DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    V. Krenn

    2014-01-01

    Full Text Available In histopathologic SLIM diagnostic (synovial-like interface membrane, SLIM apart from diagnosing periprosthetic infection particle identification has an important role to play. The differences in particle pathogenesis and variability of materials in endoprosthetics explain the particle heterogeneity that hampers the diagnostic identification of particles. For this reason, a histopathological particle algorithm has been developed. With minimal methodical complexity this histopathological particle algorithm offers a guide to prosthesis material-particle identification. Light microscopic-morphological as well as enzyme-histochemical characteristics and polarization-optical proporties have set and particles are defined by size (microparticles, macroparticles and supra- macroparticles and definitely characterized in accordance with a dichotomous principle. Based on these criteria, identification and validation of the particles was carried out in 120 joint endoprosthesis pathological cases. A histopathological particle score (HPS is proposed that summarizes the most important information for the orthopedist, material scientist and histopathologist concerning particle identification in the SLIM.

  16. Slim edges in double-sided silicon 3D detectors

    International Nuclear Information System (INIS)

    Povoli, M; Dalla Betta, G-F; Bagolini, A; Boscardin, M; Giacomini, G; Vianello, E; Zorzi, N

    2012-01-01

    Minimization of the insensitive edge area is one of the key requirements for silicon radiation detectors to be used in future silicon trackers. In 3D detectors this goal can be achieved with the active edge, at the expense of a high fabrication process complexity. In the framework of the ATLAS 3D sensor collaboration, we produced modified 3D silicon sensors with a double-sided technology. While this approach is not suitable to obtain active edges, because it does not use a support wafer, it allows for a new type of edge termination, the slim edge. In this paper we report on the development of the slim edge, from numerical simulations to design and testing, proving that it works effectively without increasing the fabrication complexity of silicon 3D detectors, and that it could be further optimized to reduce the insensitive edge region to less than 100 μm.

  17. Topography and refractometry of nanostructures using spatial light interference microscopy (SLIM)

    Science.gov (United States)

    Wang, Zhuo; Chun, Ik Su; Li, Xiuling; Ong, Zhun-Yong; Pop, Eric; Millet, Larry; Gillette, Martha; Popescu, Gabriel

    2010-01-01

    Spatial Light Interference Microscopy (SLIM) is a novel method developed in our laboratory that provides quantitative phase images of transparent structures with 0.3 nm spatial and 0.03 nm temporal accuracy owing to the white light illumination and its common path interferometric geometry. We exploit these features and demonstrate SLIM's ability to perform topography at a single atomic layer in graphene. Further, using a decoupling procedure that we developed for cylindrical structures, we extract the axially-averaged refractive index of semiconductor nanotubes and a neurite of a live hippocampal neuron in culture. We believe that this study will set the basis for novel high-throughput topography and refractometry of man-made and biological nanostructures. PMID:20081970

  18. [Wuling Capsule for climacteric patients with depression and anxiety state: a randomized, positive parallel controlled trial].

    Science.gov (United States)

    Wang, Xing-juan; Li, Ji; Zou, Qin-di; Jin, Ling

    2009-11-01

    The incidence of menopausal anxiety and depression is increasing. It can induce and aggravate a variety of somatic symptoms. Despite of the good effects of psychotropic drugs on the disease, patients' compliance is poor. Therefore, it is necessary to find a drug which is practical, effective, and easy for patients to take. To evaluate the efficacy of Wuling Capsule (WC), a Chinese herbal medicine, in treatment of female climacteric syndrome with depression and anxiety state. A total of 96 outpatients of female climacteric syndrome from Department of Gynecology of Integrated Traditional Chinese and Western Medicine, Huashan Hospital, Fudan University, Department of Gynecology of Traditional Chinese Medicine, Longhua Hospital, Shanghai University of Traditional Chinese Medicine, and Department of Traditional Chinese Medicine, Obstetrics and Gynecology Hospital, Fudan University were included. The study was designed as a randomized, positive drug parallel controlled trial. The patients were divided into WC group (64 cases) and control group (32 cases) and were orally administered Wuling Capsule and Gengnianan Tablet, respectively. The efficacy was evaluated with Kupperman menopausal index (KMI), Self-rating Depression Scale (SDS), and Self-rating Anxiety Scale (SAS) before treatment, and after 3-week and 6-week treatment. The total response rate was 89.66% (52/58) in the WC group, which was superior to that in the control group [76.67% (23/30)]. Ridit test showed that there was a significant difference between the two groups (Pstate. Wuling Capsule is more effective to alleviate depression and anxiety as compared with Gengnianan Tablet.

  19. Chromatographic fingerprinting through chemometric techniques for herbal slimming pills: A way of adulterant identification.

    Science.gov (United States)

    Shekari, Nafiseh; Vosough, Maryam; Tabar Heidar, Kourosh

    2018-05-01

    In the current study, gas chromatography-mass spectrometry (GC-MS) fingerprinting of herbal slimming pills assisted by chemometric methods has been presented. Deconvolution of two-way chromatographic signals of nine herbal slimming pills into pure chromatographic and spectral patterns was performed. The peak clusters were resolved using multivariate curve resolution-alternating least squares (MCR-ALS) by employing appropriate constraints. It was revealed that more useful chemical information about the composition of the slimming pills can be obtained by employing sophisticated GC-MS method coupled with proper chemometric tools yielding the extended number of identified constituents. The thorough fingerprinting of the complex mixtures proved the presence of some toxic or carcinogen components, such as toluene, furfural, furfuryl alcohol, styrene, itaconic anhydride, citraconic anhydride, trimethyl phosphate, phenol, pyrocatechol, p-propenylanisole and pyrogallol. In addition, some samples were shown to be adulterated with undeclared ingredients, including stimulants, anorexiant and laxatives such as phenolphthalein, amfepramone, caffeine and sibutramine. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. DeepJet: a deep-learned multiclass jet-tagger for slim and fat jets

    CERN Multimedia

    CERN. Geneva; Qu, Huilin; Stoye, Markus; Kieseler, Jan; Verzetti, Mauro

    2018-01-01

    We present a customized neural network architecture for both, slim and fat jet tagging. It is based on the idea to keep the concept of physics objects, like particle flow particles, as a core element of the network architecture. The deep learning algorithm works for most of the common jet classes, i.e. b, c, usd and gluon jets for slim jets and W, Z, H, QCD and top classes for fat jets. The developed architecture promising gains in performance as shown in simulation of the CMS collaboration. Currently the tagger is under test in real data in the CMS experiment.

  1. Characterization of applied fields for ion mobility in traveling wave based structures for lossless ion manipulations (SLIM)

    Energy Technology Data Exchange (ETDEWEB)

    Hamid, Ahmed M.; Prabhakaran Nair Syamala Amma, Aneesh; Garimella, Venkata BS; Ibrahim, Yehia M.; Smith, Richard D.

    2018-03-21

    Ion mobility (IM) is rapidly gaining attention for the analysis of biomolecules due to the ability to distinguish the shapes of ions. However, conventional constant electric field drift tube IM has limited resolving power, constrained by practical limitations on the path length and maximum applied voltage. The implementation of traveling waves (TW) in IM removes the latter limitation, allowing higher resolution to be achieved using extended path lengths. These can be readily obtainable in structures for lossless ion manipulations (SLIM), which are fabricated from electric fields that are generated by appropriate potentials applied to arrays of electrodes patterned on two parallel surfaces. In this work we have investigated the relationship between the various SLIM variables, such as electrode dimensions, inter-surface gap, and the TW applied voltages, that directly impact the fields experienced by ions. Ion simulation and theoretical calculations have been utilized to understand the dependence of SLIM geometry and effective electric field. The variables explored impact both ion confinement and the observed IM resolution in Structures for Lossless Ion Manipulations (SLIM) modules.

  2. Penerapan Peminjaman Mandiri Berbasis SLiMS Versi Desktop: Studi Kasus di Perpustakaan STAIN Kediri

    Directory of Open Access Journals (Sweden)

    Muhamad Hamim

    2016-07-01

    Full Text Available Abstrak; Layanan peminjaman mandiri adalah layanan peminjaman yang dilakukan sendiri oleh pemustaka. Peminjaman mandiri merupakan antarmuka peminjaman koleksi perpustakaan yang terkoneksi dengan database perpustakaan berbasis SLiMS sebagai pusat datanya. Tujuan layanan mandiri adalah untuk mengefektifkan layanan peminjaman di Perpustakaan STAIN Kediri yang memiliki petugas terbatas. Sebelumnya, transaksi peminjaman dilakukan oleh seorang petugas saja. Sering terjadi antrian panjang terutama ketika perpustakaan menjelang tutup atau istirahat. Sehingga diperlukan alternatif pelaksanaan transaksi peminjaman yang lebih efektif dan efisien. Layanan mandiri dikembangkan dengan menggunakan bahasa pemrograman lazarus freepascal dan mengambil data dari aplikasi senayan. Proses peminjaman dilakukan dengan melakukan verifikasi user akun pemustaka, verifikasi koleksi dan verifikasi peminjaman di database SLiMS. Abstract; Selfservice loan isa loan services conducted by the member of library themselves. Self services loan is interface loan transaction that connected to SLiMS Library database server. The purpose is to get more efectivelly loan services at Library of STAIN Kediri because of the lack of staffs. Before hand, Loan services was controlled by one operator. Long waiting line happens almost everyday asspecially at the approach of closing library or break time. however, it needed to develop the loan services that is more effective and eficient. Self sevices loan is developed by using Lazarus free Pascal software and the data is connected to senayan database. Self services loan processed is initiated from the verification of user account, verification of bibliography data and verification of loan data in the SLiMS database.

  3. Developing standardized connection analysis techniques for slim hole core rod designs

    International Nuclear Information System (INIS)

    Fehr, G.; Bailey, E.I.

    1994-01-01

    Slim hole core rod design remains essentially in the proprietary domain. API standardization provides the ability to perform engineering analyses and dimensional inspections through the use of documents, ie: Specifications, Bulletins, and Recommended Practices. In order to provide similar engineering capability for non-API slim hole connections, this paper develops the initial phase of what may evolve into an engineering tool to provide at least an indication of relative serviceability between two connection styles for a given application. The starting point for this process will look at bending strength ratios and connection strength calculations. Since empirical data are yet needed to verify the approaches proposed in this paper, it is recognized that the alternatives presented here are only a first step to developing useful rules of thumb which may lead to later standardization

  4. Simultaneous Determination of 5 Flavonoids and 7 Saponins for Quality Control of Traditional Chinese Medicine Preparation Xinnaoshutong Capsule Using HPLC-VWD-ELSD

    Directory of Open Access Journals (Sweden)

    Jin Li

    2017-01-01

    Full Text Available Xinnaoshutong capsule (XC is a traditional Chinese prescription derived from the ripe fruit of Tribulus terrestris L. (TT. Although XC has long been considered as an important herbal medicine, no analytical method of marker compounds for quality assessment is registered in the Chinese Pharmacopoeia. A simple analytical method of twelve marker components was developed and validated by HPLC-VWD-ELSD method. Chromatographic separation by HPLC was carried out on a Hedera ODS 2 column (4.6 × 250 mm, 5 μm by gradient elution with acetonitrile-water (0.1% formic acid as the mobile phase. Various extraction conditions were optimized to achieve twelve marker compounds with faster extraction and higher recovery. The analytical condition was then validated in terms of the linearity, accuracy and precision, repeatability, and stability. The twelve markers were successfully quantified in 30 batches of commercial samples. The developed HPLC-VWD-ELSD could be used as a rapid and reliable way in the assessment and quality control of XC and TT.

  5. Classifying genes to the correct Gene Ontology Slim term in Saccharomyces cerevisiae using neighbouring genes with classification learning

    Directory of Open Access Journals (Sweden)

    Tsatsoulis Costas

    2010-05-01

    Full Text Available Abstract Background There is increasing evidence that gene location and surrounding genes influence the functionality of genes in the eukaryotic genome. Knowing the Gene Ontology Slim terms associated with a gene gives us insight into a gene's functionality by informing us how its gene product behaves in a cellular context using three different ontologies: molecular function, biological process, and cellular component. In this study, we analyzed if we could classify a gene in Saccharomyces cerevisiae to its correct Gene Ontology Slim term using information about its location in the genome and information from its nearest-neighbouring genes using classification learning. Results We performed experiments to establish that the MultiBoostAB algorithm using the J48 classifier could correctly classify Gene Ontology Slim terms of a gene given information regarding the gene's location and information from its nearest-neighbouring genes for training. Different neighbourhood sizes were examined to determine how many nearest neighbours should be included around each gene to provide better classification rules. Our results show that by just incorporating neighbour information from each gene's two-nearest neighbours, the percentage of correctly classified genes to their correct Gene Ontology Slim term for each ontology reaches over 80% with high accuracy (reflected in F-measures over 0.80 of the classification rules produced. Conclusions We confirmed that in classifying genes to their correct Gene Ontology Slim term, the inclusion of neighbour information from those genes is beneficial. Knowing the location of a gene and the Gene Ontology Slim information from neighbouring genes gives us insight into that gene's functionality. This benefit is seen by just including information from a gene's two-nearest neighbouring genes.

  6. Development of a new magnetic circuit for slim microspeakers

    Science.gov (United States)

    Lee, Chang-Min; Kwon, Joong-Hak; Hwang, Gun-Yong; Hwang, Sang-Moon

    2009-04-01

    In the minimultimedia market, functional diversity, high performance, and design are given top priority. Lightweight mobile phones of unique design especially attract customer interest and are usually considered to be highly competitive items in the marketplace. Therefore, mobile phones need wider and thinner liquid crystal displays and smaller microspeakers with high acoustic performance. There are two main directions for development of slim microspeakers. One is reducing the thickness, and the other is reducing the width. In the case of reducing the width, the total magnet volume is maintained through extending the length of the magnet circuit [S. M. Hwang et al., IEEE Trans. Magn. 39, 2003 (2003)]. In contrast, reducing the thickness results in a reduction in total magnet volume unless width is increased, which causes many difficulties in the manufacturing process. In this paper, we introduce a new magnetic circuit for slim microspeakers. This new magnetic circuit, which excludes the top plate, makes it possible to manufacture slimmer microspeakers more cost-effectively without any loss of acoustic performance.

  7. A Preliminary Study of a Transdermal Radiofrequency Device for Body Slimming.

    Science.gov (United States)

    Key, Douglas J

    2015-11-01

    The use and potential of radiofrequency energy for tissue contracture and body contouring has been established in the literature. Maximum reduction of laxity can be achieved by simultaneously tightening surface tissue and reducing unwanted fat below by the transdermal application of heat to reach and maintain tissue temperature targets within a well-defined range, inducing collagen remodeling in skin as well as apoptosis of fat cells and creating an overall slimming effect. A novel device utilizes transcutaneous monopolar RF for body slimming in this manner, employing a thermistor feedback control mechanism to safely manage energy delivery and tissue temperature. Subjects (n=14) presenting with abdominal laxity were treated up to four times using the transcutaneous monopolar RF device at one or two zones in the abdominal region (at operator's discretion). Non-expert blinded graders rated correction on an arbitrary scale (0=no laxity, 4=maximum laxity) after choosing the order of the before-and-after photo sets. A patient satisfaction survey was also administered. The two graders correctly ordered 10 of 14 photo sets in agreement. Average rated improvement was 0.75 and 0.80 for graders 1 and 2, respectively. Patient survey results revealed average perceived tightening of 2.14 points on a 0 to 4 scale (0=lowest tightening result, 4=highest tightening), and 8 of 14 subjects would recommend treatment to others. Transdermal monopolar RF is a safe and effective modality for non-invasive body slimming.

  8. Field Marshal Sir William J. Slim - Paragon of Moral and Ethical Courage

    National Research Council Canada - National Science Library

    Baylor, Richard

    1998-01-01

    ... during the most desperate and brutal times. This paper looks closely at Field Marshal Slim's ethical development and leadership during his younger years, his senior leader years, and his later years...

  9. How Effective was Field Marshal William Slim as an Operational Artist?

    Science.gov (United States)

    2012-05-17

    Division having conducted an unidentified flanking maneuver to threaten his Division rear area. Slim, bedridden with dysentery, was also surprised at...Ashes: The Indian Army in the Burma Campaign. Westport: Praeger Publishers, 2003. Matheny, Michael R . The Roots of Modern American Operational Art

  10. Uneasy money: the Instituto Carlos Slim de la Salud, tobacco philanthropy and conflict of interest in global health.

    Science.gov (United States)

    Burch, Tiffany; Wander, Nathaniel; Collin, Jeff

    2010-12-01

    In May 2007, the Instituto Carso de la Salud-now Instituto Carlos Slim de la Salud (ICSS)-was endowed with US$500 million to focus on priority health issues in Latin America, notably issues of 'globalisation and non-communicable diseases'. ICSS was soon criticised, however, on the grounds that its funding was derived from tobacco industry profits and that its founder Carlos Slim Hélu remained an active industry principal. Collaboration with ICSS was said to run counter to the WHO Framework Convention on Tobacco Control. The Institute's then Executive President Julio Frenk disputed these charges. This research employs an archive of tobacco industry documents triangulated with materials from commercial, media, regulatory and NGO sources to examine the financial relations between Slim and the tobacco industry. The paper analyses Slim's continuing service to the industry and role in ICSS. It demonstrates a prima facie conflict of interest between ICSS's health mission and its founder's involvement in cigarette manufacturing and marketing, reflected on ICSS's website as a resounding silence on issues of tobacco and health. It is concluded that the reliance of international health agencies upon the commercial sector requires more robust institutional policies to effectively regulate conflicts of interest.

  11. Predictors of lifestyle intervention outcome and dropout: the SLIM study

    NARCIS (Netherlands)

    Roumen, C.; Feskens, E.J.M.; Corpeleijn, E.; Mensink, M.R.; Saris, W.H.M.; Blaak, E.E.

    2011-01-01

    Original Article European Journal of Clinical Nutrition (2011) 65, 1141–1147; doi:10.1038/ejcn.2011.74; published online 18 May 2011 Predictors of lifestyle intervention outcome and dropout: the SLIM study C Roumen1, E J M Feskens2, E Corpeleijn1, M Mensink2, W H M Saris1 and E E Blaak1 1Department

  12. Application of SLIM-MAUD: A test of an interactive computer-based method for organizing expert assessment of human performance and reliability: Volume 2, Appendices

    International Nuclear Information System (INIS)

    Spettell, C.M.; Rosa, E.A.; Humphreys, P.C.; Embrey, D.E.

    1986-10-01

    The US Nuclear Regulatory Commission (NRC) has been conducting a multiyear research program to investigate different methods for using expert judgments to estimate human error probabilities (HEPs) in nuclear power plants. One of the methods investigated, derived from multi-attribute utility theory, is the Success Likelihood Index Methodolocy implemented through Multi-Attribute Utility Decomposition (SLIM-MAUD). This report describes a systematic test application of the SLIM-MAUD methodology. The test application is evaluated on the basis of three criteria: practicality, acceptability, and usefulness. Volume I of this report represents an overview of SLIM-MAUD, describes the procedures followed in the test application, and provides a summary of the results obtained. Volume II consists of technical appendices to support in detail the materials contained in Volume I, and the users' package of explicit procedures to be followed in implementing SLIM-MAUD. The results obtained in the test application provide support for the application of SLIM-MAUD to a wide variety of applications requiring estimates of human errors

  13. The Virginia Slims identity crisis: an inside look at tobacco industry marketing to women.

    Science.gov (United States)

    Toll, B A; Ling, P M

    2005-06-01

    Because no prior studies have comprehensively analysed previously secret tobacco industry documents describing marketing female brands, the Virginia Slims brand was studied to explore how Philip Morris and competitors develop and adapt promotional campaigns targeting women. Analysis of previously secret tobacco industry documents. The majority of the documents used were from Philip Morris. The key to Virginia Slims advertising was creating an aspirational image which women associated with the brand. Virginia Slims co-opted women's liberation slogans to build a modern female image from 1968 through to the 1980s, and its market share grew from 0.24% to 3.16% during that time period. Ironically, the feminist image that worked very well for the brand was also the reason for its subsequent problems. Philip Morris experienced unprecedented losses in market share in the early 1990s, with a decline in market share for four consecutive years from 3.16% to 2.26%; they attributed this decline to both the fact that the brand's feminist image no longer appealed to young women aged 18-24 years, and increased competition from more contemporary and lower priced competitors. Throughout the 1990s, attempts to reacquire young women while retaining Virginia Slims loyal (now older) smokers were made using a "King Size" line extension, new slogans, and loyalty building promotions. Tobacco advertisers initially created distinct female brands with aspirational images; continued appeal to young women was critical for long term growth. The need for established brands to evolve to maintain relevance to young women creates an opportunity for tobacco counter-marketing, which should undermine tobacco brand imagery and promote aspirational smoke-free lifestyle images. Young women age 18-24 are extremely valuable to the tobacco industry and should be a focus for tobacco control programmes.

  14. The Virginia Slims identity crisis: an inside look at tobacco industry marketing to women

    Science.gov (United States)

    Toll, B; Ling, P

    2005-01-01

    Objectives: Because no prior studies have comprehensively analysed previously secret tobacco industry documents describing marketing female brands, the Virginia Slims brand was studied to explore how Philip Morris and competitors develop and adapt promotional campaigns targeting women. Methods: Analysis of previously secret tobacco industry documents. The majority of the documents used were from Philip Morris. Results: The key to Virginia Slims advertising was creating an aspirational image which women associated with the brand. Virginia Slims co-opted women's liberation slogans to build a modern female image from 1968 through to the 1980s, and its market share grew from 0.24% to 3.16% during that time period. Ironically, the feminist image that worked very well for the brand was also the reason for its subsequent problems. Philip Morris experienced unprecedented losses in market share in the early 1990s, with a decline in market share for four consecutive years from 3.16% to 2.26%; they attributed this decline to both the fact that the brand's feminist image no longer appealed to young women aged 18–24 years, and increased competition from more contemporary and lower priced competitors. Throughout the 1990s, attempts to reacquire young women while retaining Virginia Slims loyal (now older) smokers were made using a "King Size" line extension, new slogans, and loyalty building promotions. Conclusions: Tobacco advertisers initially created distinct female brands with aspirational images; continued appeal to young women was critical for long term growth. The need for established brands to evolve to maintain relevance to young women creates an opportunity for tobacco counter-marketing, which should undermine tobacco brand imagery and promote aspirational smoke-free lifestyle images. Young women age 18–24 are extremely valuable to the tobacco industry and should be a focus for tobacco control programmes. PMID:15923467

  15. First experimental results on active and slim-edge silicon sensors for XFEL

    International Nuclear Information System (INIS)

    Pancheri, L.; Benkechcache, M. E. A.; Betta, G.-F. Dalla; Xu, H.; Verzellesi, G.; Ronchin, S.; Boscardin, M.; Ratti, L.; Grassi, M.; Lodola, L.; Malcovati, P.; Vacchi, C.; Manghisoni, M.; Re, V.; Traversi, G.; Batignani, G.; Bettarini, S.; Casarosa, G.; Giorgi, M.; Forti, F.

    2016-01-01

    This work presents the first characterization results obtained on a pilot fabrication run of planar sensors, tailored for X-ray imaging applications at FELs, developed in the framework of INFN project PixFEL. Active and slim-edge p-on-n sensors are fabricated on n-type high-resistivity silicon with 450 μm thickness, bonded to a support wafer. Both diodes and pixelated sensors with a pitch of 110 μm are included in the design. Edge structures with different number of guard rings are designed to comply with the large bias voltage required by the application after accumulating an ionizing radiation dose as large as 1GGy. Preliminary results from the electrical characterization of the produced sensors, providing a first assessment of the proposed approach, are discussed. A functional characterization of the sensors with a pulsed infrared laser is also presented, demonstrating the validity of slim-edge configurations.

  16. Evolution of GH secretion in urine during an in-patient slimming course in obese children.

    Science.gov (United States)

    Lehingue, Y; Locard, E; Vivant, J F; Mounier, A; Serban, A; Remontet, L; Porquet, D; Joly, M O; Mamelle, N

    2000-03-01

    To estimate the change in GH excretion in urine (GH-U) during a slimming course, and if increased, to assess the components of the course related to the increase in obese children. Observational follow-up study of patients admitted for primary obesity to an in-patient slimming course lasting at least 10 weeks. 48 complete observations out of 54 consecutive pre-pubertal patients admitted to a paediatric centre for treatment of primary obesity (BMI greater than the 90th percentile of the national reference curves). GH excretion in urine by immunoradiometric assay, at entry and after 10 weeks, various anthropometric measurements, nutritional intake and departure from the prescribed diet, time spent in physical activity, sleep duration. A mean decrease of 0.90 standard deviations for BMI was accompanied by a 34% increase of GH-U. Time spent in physical activity was the only component of the course found to be related to the magnitude of GH-U increase. The results of this observational study confirm that GH-U is increased after a slimming course in children, and suggest that physical activity is a major contributor to the restoration of normal GH-U levels.

  17. Liquid-liquid displacement in slippery liquid-infused membranes (SLIMs)

    OpenAIRE

    Bazyar, Hanieh; Lv, Pengyu; Wood, Jeffery A.; Porada, Slawomir; Lohse, Detlef; Lammertink, Rob G. H.

    2018-01-01

    Liquid-infused membranes inspired by slippery liquid-infused porous surfaces (SLIPS) have been recently introduced to membrane technology. The gating mechanism of these membranes is expected to give rise to anti-fouling properties and multi-phase transport capabilities. However, the long-term retention of the infusion liquid has not yet been explored. To address this issue, we investigate the retention of the infusion liquid in slippery liquid-infused membranes (SLIMs) via liquid-liquid displ...

  18. To control and to be controlled – understanding the Arabidopsis SLIM1 function in sulfur deficiency through comprehensive investigation of the EIL protein family.

    Directory of Open Access Journals (Sweden)

    Anna eWawrzyńska

    2014-10-01

    Full Text Available SSLIM1, a member of the EIN3-like (EIL family of transcription factors in Arabidopsis, is the regulator of many sulfur-deficiency responsive genes. Among the five other proteins of the family, three regulate ethylene responses and two have unassigned functions. Contrary to the well-defined ethylene signaling, the pathway leading from sensing sulfate status to the activation of its acquisition via SLIM1 is completely unknown. SLIM1 binds to the 20 nt-long specific UPE-box sequence; however, it also recognizes the shorter TEIL sequence, unique for the whole EIL family. SLIM1 takes part in the upregulation and downregulation of various sulfur metabolism genes, but also it controls the degradation of glucosinolates under sulfur deficient conditions. Besides facilitating the increased flux through the sulfate assimilation pathway, SLIM1 induces microRNA395, specifically targeting ATP sulfurylases and a low-affinity sulfate transporter, SULTR2;1, thus affecting sulfate translocation to the shoot. Here, we briefly review the identification, structural characteristics and molecular function of SLIM1 from the perspective of the whole EIL protein family.

  19. Effect of tian meng capsule treatment on serum TGA, TMA levels in patients with hashimoto's disease

    International Nuclear Information System (INIS)

    Huang Qingyi; Chen Jianfei

    2010-01-01

    Objective: To study the effect of tian meng capsule treatment on the serum levels of TGA, TMA in patients with chronic lymphocytic thyroiditis (CLTD or Hashimoto's disease). Methods: Serum TGA and TMA levels were determined with RIA both before and after treatment for 3 months in (1) 30 patients treated with conventional drugs (2) 30 patients treated with conventional drugs plus tian meng capsule (a traditional chinese medicine preparation No.2, tid) and (3) once in 30 controls. Results: Before treatment,the serum TGA and TMA levels in all the patients were significantly, higher than those in controls. After 3 months' treatment, serum TGA and TMA levels in all the patients dropped, but the levels in the patients treated with additional tian meng capsule were significantly lower than those in patients without tian meng capsule treatment. Moreover, 76.7% of the patients with tian meng capsule treatment had their serum TGA and TMA levels decreased over 30%, four patients even had the serum levels became normal. Conclusion: tian meng capsule treatment is very effective in lowering serum TGA and TMA levels in patients with Hashimoto's disease. (authors)

  20. Efficacy of Slimming Cream Containing 3.5% Water-Soluble Caffeine and Xanthenes for the Treatment of Cellulite: Clinical Study and Literature Review

    Science.gov (United States)

    Byun, Sang-Young; Kwon, Soon-Hyo; Heo, Su-Hak; Shim, Jae-Seong; Du, Mi-Hee

    2015-01-01

    Background Cellulite is a 'cottage cheese-like' cutaneous change caused by subcutaneous fat bulging into the dermis that usually leads to cosmetic problems. Slimming cream containing 3.5% water-soluble caffeine and xanthenes exhibits a lipolytic effect with penetration into the dermis. Objective To evaluate the efficacy and safety of slimming cream for the treatment of cellulite. Methods Fifteen subjects with cellulite applied slimming cream to the thighs and inner side of the upper arms twice daily for 6 weeks. Efficacy was assessed using a standard visual scale, changes in the circumferences of the thighs and upper arms, and patient satisfaction by a questionnaire at baseline, week 3, and week 6. Safety was assessed by inquiring about adverse events through questionnaires. Results The standard visual scale score improved significantly by 0.49 points (19.8%) at week 6. Thigh and upper-arm circumferences decreased by 0.7 cm (1.7%) and 0.8 cm (2.3%), respectively, at week 6. Slight itching and transient flushing were commonly reported, but no serious adverse event occurred. Conclusion The slimming cream tested appears to be effective for the treatment of cellulitis without serious adverse effects. However, additional large clinical trials are required to confirm the efficacy and safety of slimming cream for the treatment of cellulitis. PMID:26082579

  1. Marshall Mathers, Eminem og Slim Shady : Vanhellig treenighet

    OpenAIRE

    Hjelen, Olav Inge Kamsvåg

    2008-01-01

    Denne oppgaven er en undersøkelse i Eminems imagekonstruksjoner. Ved hjelp av performansteori ønsker jeg å belyse hvordan Eminem bruker, og spiller på, forskjellige identiteter i musikken sin, og hvordan dette påvirker folks oppfatning av ham. Som oppgavens tittel foreslår, ser jeg primært på identitetene eller personaene Marshall Mathers, Eminem og Slim Shady. Jeg argumenterer for at disse bør leses som forskjellige personer, i motsetning til tre navn på samme person. Jeg foretar en lesni...

  2. Longxuetongluo Capsule Improves Erythrocyte Function against Lipid Peroxidation and Abnormal Hemorheological Parameters in High Fat Diet-Induced ApoE−/− Mice

    Directory of Open Access Journals (Sweden)

    Jiao Zheng

    2016-01-01

    Full Text Available Chinese dragon’s blood, the red resin of Dracaena cochinchinensis, one of the renowned traditional medicines, has been used to facilitate blood circulation and disperse blood stasis for thousands of years. Phenolic compounds are considered to be responsible for its main biological activities. In this study, total phenolic compounds of Chinese dragon’s blood were made into capsule (Longxuetongluo Capsule, LTC and their effects on the abnormal hemorheological properties were examined by high fat diet (HFD induced ApoE−/− mice. Compared to the model group, LTC recovered the abnormal hemorheological parameters in HFD-induced ApoE−/− mice by reducing whole blood viscosity (WBV at high rate and improving erythrocyte function. In conclusion, LTC could ameliorate erythrocyte deformability and osmotic fragility through the reduction of lipid peroxidation on plasma and erythrocyte membranes in HFD-induced ApoE−/− mice, which supported the traditional uses of Chinese dragon’s blood as an effective agent for improving blood microcirculation in hypercholesterolemia.

  3. Serotonin syndrome following overdose of a non-prescription slimming product containing sibutramine: a case report.

    Science.gov (United States)

    Lam, Pui Kin; Leung, K S; Wong, T W; Lee, H H C; Tang, M H Y; Mak, T W L

    2012-04-01

    Non-prescription slimming products are popular and can be easily purchased from the Internet. However, adulteration of these products with undeclared substances including prescription drugs is not uncommon. We report a case of serotonin syndrome after an overdose of a non-prescription product containing sibutramine. A 21-year-old woman presented with somnolence, sinus tachycardia, generalised increase in tone, hyper-reflexia and clonus more prominent in the lower limbs after an intentional overdose of a non-prescription slimming product obtained from the Internet. The product was later found to contain sibutramine and other substances such as animal thyroid tissues, caffeine and phenolphthalein. Quantitative analysis of patient's serum on presentation revealed a sibutramine concentration of 112 ng/mL, which far exceeded the reported peak serum concentration after a single oral dose of 15 mg (the maximum daily recommended dose). No other culpable agent was identified. The overall clinical presentation was compatible with serotonin syndrome associated with sibutramine overdose. The patient made a full recovery after supportive management. This case highlighted the health threat posed by non-prescription slimming products sold over the Internet. Sibutramine overdose can result in serotonin syndrome, as in overdose of other serotonergic agents. Early recognition and timely supportive treatment are essential to ensure a good clinical outcome.

  4. The Impact of Media Literacy Intervention on the Students\\' Attitudes about Self-Medication of Slimming Supplements

    Directory of Open Access Journals (Sweden)

    Mahnaz Solhi

    2016-05-01

    Full Text Available Background and objective: Self-medication of slimming supplements has increased. Media advertising is involved in this field. The aim of the present study was to determine the effect of media literacy educational intervention in the students' attitudes about self-medication of slimming supplements among the female dormitories in University of Medical Sciences in Iran. Methods: In this quasi-experimental study of controlled type, 98 students were selected by multistage cluster sampling method and randomly divided into two groups of 49 tests and 49 control. The data collecting instruments were the researcher-made questionnaire about media literacy and attitude on self-medication of slimming pills, BICI questionnaire of body image, and SEI Cooper Smith's questionnaire of self-esteem. Based on the results obtained from the questionnaires early completion, an appropriate educational intervention was designed and carried out. One and three months after the intervention, data was gathered and analyzed in (16 SPSS software using descriptive and analytical tests. Results: Before the intervention, the mean scores of attitude, body image, self-esteem, and dimensions of media literacy in both groups were moderate, and there was no significant difference between them. Also, positive correlations were observed in the experiment group between attitude and knowledge (r = 0.99, p = 0.001, critical thinking (r = 0.61, p = 0.001 and analysis (r=0.37, p=0.009. One and three months after the intervention, the mean scores of  body image, self-esteem, and dimensions of media literacy were  observed significant in  both groups (p <0.05. Conclusion: Media literacy education was effective in promoting the attitude about slimming supplements. Paper Type: Research Article.

  5. Phase 2 Reese River Geothermal Project Slim Well 56-4 Drilling and Testing

    Energy Technology Data Exchange (ETDEWEB)

    Henkle, William R.; Ronne, Joel

    2008-06-15

    This report covers the drilling and testing of the slim well 56-4 at the Reese River Geothermal Project in Lander County, Nevada. This well was partially funded through a GRED III Cooperative Funding Agreement # DE-FC36-04GO14344, from USDOE.

  6. Mining Concept Maps from News Stories for Measuring Civic Scientific Literacy in Media

    Science.gov (United States)

    Tseng, Yuen-Hsien; Chang, Chun-Yen; Rundgren, Shu-Nu Chang; Rundgren, Carl-Johan

    2010-01-01

    Motivated by a long-term goal in education for measuring Taiwanese civic scientific literacy in media (SLiM), this work reports the detailed techniques to efficiently mine a concept map from 2 years of Chinese news articles (901,446 in total) for SLiM instrument development. From the Chinese news stories, key terms (important words or phrases),…

  7. Chinese Herbs Containing Aristolochic Acid Associated with Renal Failure and Urothelial Carcinoma: A Review from Epidemiologic Observations to Causal Inference

    OpenAIRE

    Yang, Hsiao-Yu; Chen, Pau-Chung; Wang, Jung-Der

    2014-01-01

    Herbal remedies containing aristolochic acid (AA) have been designated to be a strong carcinogen. This review summarizes major epidemiologic evidence to argue for the causal association between AA exposure and urothelial carcinoma as well as nephropathy. The exposure scenarios include the following: Belgian women taking slimming pills containing single material Guang Fang Ji, consumptions of mixtures of Chinese herbal products in the general population and patients with chronic renal failure ...

  8. Simulation of density curve for slim borehole using the Monte Carlo code MCNPX

    International Nuclear Information System (INIS)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu; Lima, Inaya C.B.; Rocha, Paula L.F.

    2010-01-01

    Borehole logging for formation density has been an important geophysical measurement in oil industry. For calibration of the Gamma Ray nuclear logging tool, numerous rock models of different lithology and densities are necessary. However, the full success of this calibration process is determined by a reliable benchmark, where the complete and precise chemical composition of the standards is necessary. Simulations using the Monte Carlo MCNP have been widely employed in well logging application once it serves as a low-cost substitute for experimental test pits, as well as a means for obtaining data that are difficult to obtain experimentally. Considering this, the purpose of this work is to use the code MCNP to obtain density curves for slim boreholes using Gamma Ray logging tools. For this, a Slim Density Gamma Probe, named TRISOND R , and a 100 mCi Cs-137 gamma source has been modeled with the new version of MCNP code MCNPX. (author)

  9. Simulation of density curve for slim borehole using the Monte Carlo code MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Edmilson Monteiro de; Silva, Ademir Xavier da; Lopes, Ricardo Tadeu, E-mail: emonteiro@nuclear.ufrj.b, E-mail: ademir@nuclear.ufrj.b, E-mail: ricardo@lin.ufrj.b [Coordenacao dos Programas de Pos-Graduacao de Engenharia (COPPE/UFRJ), RJ (Brazil). Programa de Engenharia Nuclear; Correa, Samanda Cristine Arruda, E-mail: scorrea@nuclear.ufrj.b [Centro Universitario Estadual da Zona Oeste (CCMAT/UEZO), Rio de Janeiro, RJ (Brazil); Lima, Inaya C.B., E-mail: inaya@lin.ufrj.b [Universidade Estadual do Rio de Janeiro (IPRJ/UERJ) Nova Friburgo, Rio de Janeiro, RJ (Brazil). Instituto Politecnico do Rio de Janeiro; Rocha, Paula L.F., E-mail: ferrucio@acd.ufrj.b [Universidade Federal do Rio de Janeiro (UFRJ) RJ (Brazil). Dept. de Geologia

    2010-07-01

    Borehole logging for formation density has been an important geophysical measurement in oil industry. For calibration of the Gamma Ray nuclear logging tool, numerous rock models of different lithology and densities are necessary. However, the full success of this calibration process is determined by a reliable benchmark, where the complete and precise chemical composition of the standards is necessary. Simulations using the Monte Carlo MCNP have been widely employed in well logging application once it serves as a low-cost substitute for experimental test pits, as well as a means for obtaining data that are difficult to obtain experimentally. Considering this, the purpose of this work is to use the code MCNP to obtain density curves for slim boreholes using Gamma Ray logging tools. For this, a Slim Density Gamma Probe, named TRISOND{sup R}, and a 100 mCi Cs-137 gamma source has been modeled with the new version of MCNP code MCNPX. (author)

  10. Tongxinluo (Tong xin luo or Tong-xin-luo) capsule for unstable angina pectoris.

    Science.gov (United States)

    Wu, Taixiang; Harrison, R A; Chen, Xiaoyan; Ni, Juan; Zhou, Likun; Qiao, Jieqi; Wang, Qin; Wei, Jiafu; Xin, Duan; Zheng, Jie

    2006-10-18

    Tongxinluo capsule is a medicine consisting of traditional Chinese herbs and insects used for cardiovascular diseases in China and some other Asian countries. To date the evidence of its effect has not previously been subject to systematic review, making it difficult to derive robust conclusions about its actual benefits, and indeed, possible harms. To assess systematically the effects of tongxinluo capsule in people with unstable angina pectoris. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library, Issue 4 2004, MEDLINE, EMBASE, Chinese Biomedical Database, China National Knowledge Infrastructure, Japana Centra Revuo Medicina (all 1995 to 2005). We also handsearched the relevant Chinese journals, checked with manufacturers and registers of ongoing studies. Randomised trials comparing either tongxinluo capsule only or standard treatment plus tongxinluo capsule with standard treatment or other anti-angina pectoris drugs, placebo or no intervention. Two authors identified relevant studies for the review independently and went on to abstract data, and assess trial quality. Authors of included studies were contacted to obtain further information as required. 18 short term follow-up trials involving 1413 people were included. The studies did not provide strong support of a benefit of tongxinluo for reducing the combined outcome of acute myocardial infarction, angioplasty (PTCA) coronary artery bypass graft (CABG) and sudden death or all-cause mortality (RR 0.42, 95% CI 0.07 to 2.59, P=0.35; RR 0.33, 95% CI 0.01to 7.78, P=0.49, respectively). Tongxinluo reduced the frequency of acute angina attacks (WMD -1.20, 95%CI -1.38 to -1.02, P<0.00001 and RR -2.36, 95%CI -2.53 to -2.18, P<0.00001, respectively), improved ECG (RR 1.31, 95% CI 1.08 to 1.57, P=0.005) and angina symptoms (RR 1.21, 95% CI 1.06 to 1.40; P=0.007). Tongxinluo in combination with routine angina therapy appears to reduce the risk of subsequent AMI, PTCA or CABG

  11. Crump Geyser Exploration and Drilling Project. High Precision Geophysics and Detailed Structural Exploration and Slim Well Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Fairbank, Brian D. [Nevada Geothermal Power Company, Vancouver (Canada); Smith, Nicole [Nevada Geothermal Power Company, Vancouver (Canada)

    2015-06-10

    The Crump Geyser Exploration and Drilling Project – High Precision Geophysics and Detailed Structural Exploration and Slim Well Drilling ran from January 29, 2010 to September 30, 2013. During Phase 1 of the project, collection of all geophysical surveys was completed as outlined in the Statement of Project Objectives. In addition, a 5000-foot full sized exploration well was drilled by Ormat, and preexisting drilling data was discovered for multiple temperature gradient wells within the project area. Three dimensional modeling and interpretation of results from the geophysical surveys and drilling data gave confidence to move to the project into Phase 2 drilling. Geological and geophysical survey interpretations combined with existing downhole temperature data provided an ideal target for the first slim-hole drilled as the first task in Phase 2. Slim-hole 35-34 was drilled in September 2011 and tested temperature, lithology, and permeability along the primary range-bounding fault zone near its intersection with buried northwest-trending faults that have been identified using geophysical methods. Following analysis of the results of the first slim-hole 35-34, the second slim hole was not drilled and subsequent project tasks, including flowing differential self-potential (FDSP) surveys that were designed to detail the affect of production and injection on water flow in the shallow aquifer, were not completed. NGP sold the Crump project to Ormat in August 2014, afterwards, there was insufficient time and interest from Ormat available to complete the project objectives. NGP was unable to continue managing the award for a project they did not own due to liability issues and Novation of the award was not a viable option due to federal award timelines. NGP submitted a request to mutually terminate the award on February 18, 2015. The results of all of the technical surveys and drilling are included in this report. Fault interpretations from surface geology, aeromag

  12. The Scaling LInear Macroweather model (SLIM): using scaling to forecast global scale macroweather from months to decades

    Science.gov (United States)

    Lovejoy, S.; del Rio Amador, L.; Hébert, R.

    2015-03-01

    At scales of ≈ 10 days (the lifetime of planetary scale structures), there is a drastic transition from high frequency weather to low frequency macroweather. This scale is close to the predictability limits of deterministic atmospheric models; so that in GCM macroweather forecasts, the weather is a high frequency noise. But neither the GCM noise nor the GCM climate is fully realistic. In this paper we show how simple stochastic models can be developped that use empirical data to force the statistics and climate to be realistic so that even a two parameter model can outperform GCM's for annual global temperature forecasts. The key is to exploit the scaling of the dynamics and the enormous stochastic memories that it implies. Since macroweather intermittency is low, we propose using the simplest model based on fractional Gaussian noise (fGn): the Scaling LInear Macroweather model (SLIM). SLIM is based on a stochastic ordinary differential equations, differing from usual linear stochastic models (such as the Linear Inverse Modelling, LIM) in that it is of fractional rather than integer order. Whereas LIM implicitly assumes there is no low frequency memory, SLIM has a huge memory that can be exploited. Although the basic mathematical forecast problem for fGn has been solved, we approach the problem in an original manner notably using the method of innovations to obtain simpler results on forecast skill and on the size of the effective system memory. A key to successful forecasts of natural macroweather variability is to first remove the low frequency anthropogenic component. A previous attempt to use fGn for forecasts had poor results because this was not done. We validate our theory using hindcasts of global and Northern Hemisphere temperatures at monthly and annual resolutions. Several nondimensional measures of forecast skill - with no adjustable parameters - show excellent agreement with hindcasts and these show some skill even at decadal scales. We also compare

  13. Interpolis SlimOpWeg-programma : de AutoModus-app : vragenlijstonderzoek naar het effect van een app om smartphonegebruik in de auto te verminderen.

    NARCIS (Netherlands)

    Groot-Mesken, J. de Wijnen, W. Stelling-Konczak, A. & Commandeur, J.J.F.

    2017-01-01

    Interpolis SlimOpWeg programme: the AutoModus app; Survey into the effect of an app on reducing smartphone use while driving a car. Within the programme SlimOpWeg the Dutch insurance company Interpolis had a smartphone app developed. The purpose of this ‘AutoModus app’ is to help young drivers to

  14. Posterior capsule opacification.

    Science.gov (United States)

    Wormstone, I Michael; Wang, Lixin; Liu, Christopher S C

    2009-02-01

    Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.

  15. Room temperature thin foil SLIM-cut using an epoxy paste: experimental versus theoretical results

    International Nuclear Information System (INIS)

    Bellanger, Pierre; Serra, Joao; Bouchard, Pierre-Olivier; Bernacki, Marc

    2015-01-01

    The stress induced lift-off method (SLIM) -cut technique allows the detachment of thin silicon foils using a stress inducing layer. In this work, results of SLIM-cut foils obtained using an epoxy stress inducing layer at room temperature are presented. Numerical analyses were performed in order to study and ascertain the important experimental parameters. The experimental and simulation results are in good agreement. Indeed, large area (5 × 5 cm 2 ) foils were successfully detached at room temperature using an epoxy thickness of 900 μm and a curing temperature of 150 °C. Moreover, three foils (5 × 3 cm 2 ) with thickness 135, 121 and 110 μm were detached from the same monocrystalline substrate. Effective minority carrier lifetimes of 46, 25 and 20 μs were measured using quasi-steady-state photoconductance technique in these foils after iodine ethanol surface passivation. (paper)

  16. Analysis of Harmonics Suppression by Active Damping Control on Multi Slim DC-link Drives

    DEFF Research Database (Denmark)

    Yang, Feng; Máthé, Lászlo; Lu, Kaiyuan

    2016-01-01

    Compared with conventional dc-link drive, slim dc-link drive is expected to achieve lower cost and longer life time. However, harmonics distortion problem may occur in such drive systems. This paper proposes to use an active damping control method to suppress the harmonic distortion...... with the benefit of low cost and also low loss. A new analysis method, based on the frequency domain impedance model, is presented to explore the mechanism of harmonics suppression. Also, a general method is presented to build the impedance model of a PMSM drive system using Field Oriented Control (FOC) method....... Some design issues, including power levels, current control bandwidth and harmonic interaction, are discussed when the drive system is fed by a weak grid. Case studies on a two-drive system composed by two slim dc-link drive units are provided to verify the proposed analysis method....

  17. [Efficacy and safety of Longjintonglin Capsule for the treatment of type III prostatitis].

    Science.gov (United States)

    Shang, Xue-Jun; Geng, Qiang; Duan, Jian-Min; Zheng, De-Quan; Xie, Lei; Guo, Jun

    2014-12-01

    To study the therapeutic effect and safety of Longjintonglin Capsule in the treatment of type III prostatitis (chronic prostatitis/chronic pelvic pain syndrome, CP/CPPS). We selected 240 patients with type III prostatitis according to the diagnostic standards of the American National Institute of Health (NIH) and treated them with Longjintonglin Capsule orally 3 capsules once tid for 12 weeks. Based on the NIH chronic prostatitis symptom index (NIH-CPSI), traditional Chinese medicine (TCM) syndrome score, and leukocyte count in the expressed prostatic secretion (EPS), we evaluated the results of treatment. Totally 238 patients completed the treatment, including 108 IIIA and 120 III B prostatitis cases. Before and after 4, 8, and 12 weeks of treatment, the total NIH-CPSI scores were 23.12 ± 6.99, 18.22 ± 6.39, 14.12 ± 5.88, and 12.36 ± 6.04 (P prostatitis patients and 22.01 ± 6.28, 17.56 ± 5.89, 13.67 ± 5.18, and 11.45 ± 5.22 in the III prostatitis patients (P prostatitis, deserves to be recommended for clinical application.

  18. Adapting the SLIM diabetes prevention intervention to a Dutch real-life setting: joint decision making by science and practice.

    Science.gov (United States)

    Jansen, Sophia C; Haveman-Nies, Annemien; Duijzer, Geerke; Ter Beek, Josien; Hiddink, Gerrit J; Feskens, Edith J M

    2013-05-08

    Although many evidence-based diabetes prevention interventions exist, they are not easily applicable in real-life settings. Moreover, there is a lack of examples which describe the adaptation process of these interventions to practice. In this paper we present an example of such an adaptation. We adapted the SLIM (Study on Lifestyle intervention and Impaired glucose tolerance Maastricht) diabetes prevention intervention to a Dutch real-life setting, in a joint decision making process of intervention developers and local health care professionals. We used 3 adaptation steps in accordance with current adaptation frameworks. In the first step, the elements of the SLIM intervention were identified. In the second step, these elements were judged for their applicability in a real-life setting. In the third step, adaptations were proposed and discussed for those elements which were deemed not applicable. Participants invited for this process included intervention developers and local health care professionals (n=19). In the first adaptation step, a total of 22 intervention elements were identified. In the second step, 12 of these 22 intervention elements were judged as inapplicable. In the third step, a consensus was achieved for the adaptations of all 12 elements. The adapted elements were in the following categories: target population, techniques, intensity, delivery mode, materials, organisational structure, and political and financial conditions. The adaptations either lay in changing the SLIM protocol (6 elements) or the real-life working procedures (1 element), or a combination of both (4 elements). The positive result of this study is that a consensus was achieved within a relatively short time period (nine months) between the developers of the SLIM intervention and local health care professionals on the adaptations needed to make SLIM applicable in a Dutch real-life setting. Our example shows that it is possible to combine the perspectives of scientists and

  19. Body image and eating attitudes among adolescent Chinese girls in Hong Kong.

    Science.gov (United States)

    Fung, Maria S C; Yuen, Mantak

    2003-02-01

    The study investigated the relation between body image and eating attitudes among adolescent girls in Hong Kong. A sample of 358 senior secondary school girls completed the measures assessing body-part satisfaction and behaviors associated with eating. Analysis indicated that even though only 4.8% of the girls were overweight, 85.16% desired to weigh less. These Chinese teenage girls were concerned about their weight, and the desire for slimness was widespread. Correlations indicated that higher Body Mass Index was associated with lower satisfaction with weight. Lower scores on weight satisfaction were associated with higher scores on attitudes of dieting and food preoccupation.

  20. Inspiration or deflation? Feeling similar or dissimilar to slim and plus-size models affects self-evaluation of restrained eaters.

    Science.gov (United States)

    Papies, Esther K; Nicolaije, Kim A H

    2012-01-01

    The present studies examined the effect of perceiving images of slim and plus-size models on restrained eaters' self-evaluation. While previous research has found that such images can lead to either inspiration or deflation, we argue that these inconsistencies can be explained by differences in perceived similarity with the presented model. The results of two studies (ns=52 and 99) confirmed this and revealed that restrained eaters with high (low) perceived similarity to the model showed more positive (negative) self-evaluations when they viewed a slim model, compared to a plus-size model. In addition, Study 2 showed that inducing in participants a similarities mindset led to more positive self-evaluations after viewing a slim compared to a plus-size model, but only among restrained eaters with a relatively high BMI. These results are discussed in the context of research on social comparison processes and with regard to interventions for protection against the possible detrimental effects of media images. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Effects of food on a gastrically degraded drug: azithromycin fast-dissolving gelatin capsules and HPMC capsules.

    Science.gov (United States)

    Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa

    2011-07-01

    Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin

  2. Qualitative and Quantitative Analysis of the Major Constituents in Chinese Medical Preparation Lianhua-Qingwen Capsule by UPLC-DAD-QTOF-MS

    Directory of Open Access Journals (Sweden)

    Weina Jia

    2015-01-01

    Full Text Available Lianhua-Qingwen capsule (LQC is a commonly used Chinese medical preparation to treat viral influenza and especially played a very important role in the fight against severe acute respiratory syndrome (SARS in 2002-2003 in China. In this paper, a rapid ultraperformance liquid chromatography coupled with diode-array detector and quadrupole time-of-flight mass spectrometry (UPLC-DAD-QTOF-MS method was established for qualitative and quantitative analysis of the major constituents of LQC. A total of 61 compounds including flavonoids, phenylpropanoids, anthraquinones, triterpenoids, iridoids, and other types of compounds were unambiguously or tentatively identified by comparing the retention times and accurate mass measurement with reference compounds or literature data. Among them, twelve representative compounds were further quantified as chemical markers in quantitative analysis, including salidroside, chlorogenic acid, forsythoside E, cryptochlorogenic acid, amygdalin, sweroside, hyperin, rutin, forsythoside A, phillyrin, rhein, and glycyrrhizic acid. The UPLC-DAD method was evaluated with linearity, limit of detection (LOD, limit of quantification (LOQ, precision, stability, repeatability, and recovery tests. The results showed that the developed quantitative method was linear, sensitive, and precise for the quality control of LQC.

  3. Rare Particle Searches with the high altitude SLIM experiment

    CERN Document Server

    Balestra, S; Fabbri, F; Giacomelli, G; Giacomelli, R; Giorgini, M; Kumar, A; Manzoor, S; McDonald, J; Margiotta, A; Medinaceli, E; Nogales, J; Patrizii, L; Popa, V; Quereshi, I; Saavedra, O; Sher, G; Shahzad, M; Spurio, M; Ticona, R; Togo, V; Velarde, A; Zanini, A

    2005-01-01

    The search for rare particles in the cosmic radiation remains one of the main aims of non-accelerator particle astrophysics. Experiments at high altitude allow lower mass thresholds with respect to detectors at sea level or underground. The SLIM experiment is a large array of nuclear track detectors located at the Chacaltaya High Altitude Laboratory (5290 m a.s.l.). The preliminary results from the analysis of a part of the first 236 sq.m exposed for more than 3.6 y are here reported. The detector is sensitive to Intermediate Mass Magnetic Monopoles and to SQM nuggets and Q-balls, which are possible Dark Matter candidates.

  4. Perilaku Pemustaka Dalam Temu Kembali Koleksi Dengan Menggunakan OPAC Berbasis SLIMS

    Directory of Open Access Journals (Sweden)

    Mujiati Mujiati

    2014-07-01

    Full Text Available Abstract: An  increase of  library collection and  information explosion causes  problems  on    information  retrieval  for  library  users.  Those explosion will be helpful for users using Online Public Access Catalog (OPAC. This article tries to explore the use of OPAC based SLIMs on STAIN Ponorogo  library. OPAC proves  to help users  on  retrieval  be easier and faster, beside its obstacles

  5. Identification of chemical components in Baidianling Capsule based on gas chromatography-mass spectrometry and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui

    2017-08-01

    Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Status of the material capsule irradiation and the development of the new capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Kang, Young-Hwan; Choi, Myoung-Hwan; Cho, Man-Soon; Kim, Bong-Goo

    2006-01-01

    A material capsule system including a main capsule, fixing, control, cutting, and transport systems was developed for an irradiation test of non-fissile materials in HANARO. 14 irradiation capsules (12 instrumented and 2 non-instrumented capsules) have been designed, fabricated and successfully irradiated in the HANARO CT and IR test holes since 1995. The capsules were mainly designed for an irradiation of the RPV (Reactor Pressure Vessel), reactor core materials, and Zr-based alloys. Most capsules were made for KAERI material research projects, but 5 capsules were made as a part of national projects for the promotion of the HANARO utilization for universities. Based on the accumulated irradiation experience and the user's sophisticated requirements, development of new instrumented capsule technologies for a more precise control of the irradiation temperature and fluence of a specimen irrespective of the reactor operation has been performed in HANARO. (author)

  7. A case of dilated cardiomyopathy with massive left ventricular thrombus after use of a sibutramine-containing slimming product.

    Science.gov (United States)

    Heo, Seung Hye; Kang, Min-Ho

    2013-09-01

    Sibutramine, which acts as an anti-obesity drug by inhibiting reuptake of serotonin and norepinephrine, has now been banned due to cardiovascular adverse effects. However, despite being banned, it is not uncommon for people to purchase products with sibutramine or its analogues used as adulterants in non-prescription slimming products or health foods available on the internet. Sibutramine has been associated with rare but serious adverse reactions such as cardiac arrhythmia including QT interval prolongation, myocardial infarction, and cardiomyopathy, as well as increases in blood pressure and pulse rate. Here, we report a case of a 32-year-old male who presented with dilated cardiomyopathy with massive left ventricular thrombus after taking unauthorized sibutramine-containing slimming pills sold over the internet.

  8. [The adipocyte in the history of slimming agents].

    Science.gov (United States)

    Franchi, J; Pellicier, F; André, P; Schnebert, S

    2003-07-01

    Nowadays, in industrialised societies, it is fashionable for women to be slim. However, throughout history, this has not always been the case, especially as "cellulite" (cellulitis) was full of typically feminine symbols. The ideal feminine silhouette has changed with the rhythm of cultures. Cellulitis is an inappropriate term used by women to describe curves which they judge to be too plump and not very aesthetic, mostly around the thighs and hips. This lipodystrophy of the adipose tissue represents approximately 25% of a woman's body weight. It is clinically characterised by an "orange peel" skin surface, which is a result of the excessive development of the volume of the adipocytes organised in lobules within the walls of the unstretchable conjunctive tissue. This phenomenon is associated with an insufficiency of the venous tonus and an increase in the capillary permeability, which both contribute to an increase in the infiltration of water in the tissue. In reality, the understanding of cellulite has truly progressed with research based on adipocyte functions. An adipocyte is a metabolically active cell which plays a central role in the control of the energetic balance of the organism. In order to assume this role, it possesses all the enzymatic equipment necessary for synthesis (lipogenesis) and for triglyceride storage, mobilisation and liberation as free fatty acids (lipolysis). During these last few years, as well as this role as an energetic reserve which manages lipogenesis/lipolysis balance, the adipocyte has acquired the status of an endocrine and paracrine cell through the identification of numerous secreted factors. When we look back at the history of slimming products launched on the market since the 1980's, we can notice the role of the adipocyte tool and understand its functions in the choice of active ingredients, the development of complementary actions, the importance of the texture, the evolution of methods used to evaluate the efficacy on

  9. Summary Report for Capsule Dry Storage Project

    Energy Technology Data Exchange (ETDEWEB)

    JOSEPHSON, W S

    2003-09-04

    There are 1.936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project (CDSP) is conducted under the assumption the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event vitrification of the capsule contents is pursued. A cut away drawing of a typical cesium chloride (CsCI) capsule and the capsule property and geometry information are provided in Figure 1.1. Strontium fluoride (SrF{sub 2}) capsules are similar in design to CsCl capsules. Further details of capsule design, current state, and reference information are given later in this report and its references. Capsule production and life history is covered in WMP-16938, Capsule Characterization Report for Capsule Dry Storage Project, and is briefly summarized in Section 5.2 of this report.

  10. The Relationship between Role Concerns, Preferences for Slimness, and Symptoms of Eating Problems among College Women.

    Science.gov (United States)

    Silverstein, Brett; Perdue, Lauren

    1988-01-01

    Among college women, the desire for slim, noncurvaceous bodies associated with dieting and binging is correlated with an emphasis on physical attractiveness. This desire, associated with purging and underweight, is based on the belief that thin women are perceived as more intelligent. (Author/BJV)

  11. Analytical Model for the Probability Characteristics of a Crack Penetrating Capsules in Capsule-Based Self-Healing Cementitious Materials

    Directory of Open Access Journals (Sweden)

    Zhong LV

    2017-08-01

    Full Text Available Autonomous crack healing using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of capsule-based self-healing materials. Continuing our previous study, in this contribution a more practical rupturing mode of capsules characterizing the rupturing manner of capsules fractured by cracks in cementitious materials is presented, i.e., penetrating mode. With the underlying assumption that a crack penetrating capsules undoubtedly leads to crack healing, geometrical probability theory is employed to develop the quantitative relationship between crack size and capsule size, capsule concentration in capsule-based self-healing virtual cementitious material. Moreover, an analytical expression of probability of a crack penetrating with randomly dispersed capsules is developed in two-dimensional material matrix setup. The influences of the induced rupturing modes of capsules embedded on the self-healing efficiency are analyzed. Much attention is paid to compare the penetrating probability and the hitting probability, in order to assist the designer to make a choice of the optimal rupturing modes of capsules embedded. The accuracy of results of the theoretical model is also compared with Monte-Carlo numerical analysis of crack interacting with capsules. It shows that the developed probability characteristics of a crack interaction with capsules for different rupturing modes is helpful to provide guidelines for designer working with capsule-based self-healing cementitious materials.DOI: http://dx.doi.org/10.5755/j01.ms.23.3.16888

  12. Polydopamine-coated capsules

    Science.gov (United States)

    White, Scott R.; Sottos, Nancy R.; Kang, Sen; Baginska, Marta B.

    2018-04-17

    One aspect of the invention is a polymer material comprising a capsule coated with PDA. In certain embodiments, the capsule encapsulates a functional agent. The encapsulated functional agent may be an indicating agent, healing agent, protecting agent, pharmaceutical drug, food additive, or a combination thereof.

  13. Rapid Surface Enhanced Raman Scattering (SERS) Detection of Sibutramine Hydrochloride in Pharmaceutical Capsules with a β-Cyclodextrin- Ag/Polyvivnyl Alcohol Hydrogel Substrate.

    Science.gov (United States)

    Ouyang, Lei; Jiang, Zuyan; Wang, Nan; Zhu, Lihua; Tang, Heqing

    2017-07-10

    Sibutramine hydrochloride (SH) is a banned weight-loss drug, but its illegal addition to health products is still rampant. This suggests a very urgent need for a fast and precise detection method for SH. Surface Enhanced Raman Scattering (SERS) is a promising candidate for this purpose, but the weak affinity between SH and bare metal limits its direct SERS detection. In the present work, β-cyclodextrin was capped in situ onto the surface of Ag nanoparticles to function as a scaffold to capture SH. The obtained Ag nanoparticles were encapsulated into polyvinyl alcohol (PVA) to fabricate a SERS active hydrogel with excellent reproducibility. A facile SERS strategy based on such substrate was proposed for trace SH quantification with a linear range of 7.0-150.0 µg·mL -1 , and a detection limit low to 3.0 µg·mL -1 . It was applied to analyze seven types of commercial slimming capsules with satisfactory results, showing good prospect for real applications.

  14. [Effects of the body fat mass and blood sugar and plasma resistin to slim exercise prescription for overweight and obesity students].

    Science.gov (United States)

    Bai, Youping; Zhang, Jing; Jiang, Shuangshuang; Sun, Jun; Zheng, Chenfei; Wang, Ke; Qian, Jingjing; Nie, Liuwang

    2013-07-01

    To explore the influences of slim exercise prescription on body fat mass, blood sugar and plasma resistin for overweight and obesity students. Subjects were 9 males and 13 females for simple overweight and obesity students of freshman and junior. The function capacity (FC) were defined after examine of body shape, physical function and exercise capacity. The slim goals and exercise projects were determined according to different objects. The exercise intensity was 60%-70% of FC and 13-15 levels of RPE. Exercise with each time was 60 min, exercise frequency was 5 times perweek, energy metabolism was 500-600 kcal at a time. The relative indexes were detected after 8 weeks. Implementing programmes of slim exercise prescription for 8 weeks, before and after the experiment in the males and females group. The weight, BMI, percentage of body fat (FAT%), waist and hip circumference ratio (WHR), body surface area (BS), fat indexes, the density of body for overweight and obesity the male and female students were significantly decreased (P exercise prescription was safe and sure, and could improve weight, BMI, FAT%, FM, WHR, BS, fat indexes, the density of body, blood sugar, plasma resistin in obesity without the diet control.

  15. Hot cell examination on the surveillance capsule and HANARO capsule in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong Sun; Oh, Wan Ho; Yoo, Byung Ok; Jung, Yang Hong; Ahn, Sang Bok; Baik, Seung Je; Song, Wung Sup; Hong, Kwon Pyo

    2000-01-01

    For the maintenance of integrity and safety of pressurizer of commercial power plant until its life span, it is required by US NRC 10CFR50 APP. G and H and ASTM E185-94 to periodically monitor irradiation embrittlement by neutron irradiation. In order to accomplished the requirement reactor operator has been carrying out the test by extracting the monitoring capsule embeded in reactor during the period of planned preventive maintenance. In relation to this irradiation samples are being used for prediction of reactor vessel life span and reactor vessel's adjusted reference temperature by irradiation of neutron flux enough to reach to end of life span. And also irradiation capsules with and without instrumentation are used for R and D on nuclear materials. Each capsule contains high radioactivity, therefore, post irradiation examination has to be handled by all means in the hot cell. The facility available for this purpose is Irradiated material examination facility (IMEF) to handle such works as capsule receiving, capsule cut and dismantling, sample classification, various examination, and finally development and improvement of examination equipment and instrumentation. (Hong, J. S.)

  16. Search for massive rare particles with the SLIM experiment

    CERN Document Server

    Balestra, S.; Fabbri, F.; Giacomelli, G.; Kumar, A.; Manzoor, S.; McDonald, J.; Medinaceli, E.; Nogales, J.; Patrizii, L.; Pinfold, J.; Popa, V.; Qureshi, I.; Saavedra, O.; Sher, G.; Shahzad, M.; Spurio, M.; Ticona, R.; Togo, V.; Velarde, A.; Zanini, A.

    2005-01-01

    The search for magnetic monopoles in the cosmic radiation remains one of the main aims of non-accelerator particle astrophysics. Experiments at high altitude allow lower mass thresholds with respect to detectors at sea level or underground. The SLIM experiment is a large array of nuclear track detectors at the Chacaltaya High Altitude Laboratory (5290 m a.s.l.). The results from the analysis of 171 m$^2$ exposed for more than 3.5 y are here reported. The completion of the analysis of the whole detector will allow to set the lowest flux upper limit for Magnetic Monopoles in the mass range 10$^5$ - 10$^{12}$ GeV. The experiment is also sensitive to SQM nuggets and Q-balls, which are possible Dark Matter candidates.

  17. Chinese Herbs Containing Aristolochic Acid Associated with Renal Failure and Urothelial Carcinoma: A Review from Epidemiologic Observations to Causal Inference

    Directory of Open Access Journals (Sweden)

    Hsiao-Yu Yang

    2014-01-01

    Full Text Available Herbal remedies containing aristolochic acid (AA have been designated to be a strong carcinogen. This review summarizes major epidemiologic evidence to argue for the causal association between AA exposure and urothelial carcinoma as well as nephropathy. The exposure scenarios include the following: Belgian women taking slimming pills containing single material Guang Fang Ji, consumptions of mixtures of Chinese herbal products in the general population and patients with chronic renal failure in Taiwan, occupational exposure in Chinese herbalists, and food contamination in farming villages in valleys of the Danube River. Such an association is corroborated by detecting specific DNA adducts in the tumor tissue removed from affected patients. Preventive actions of banning such use and education to the healthcare professionals and public are necessary for the safety of herbal remedies.

  18. Chinese herbs containing aristolochic acid associated with renal failure and urothelial carcinoma: a review from epidemiologic observations to causal inference.

    Science.gov (United States)

    Yang, Hsiao-Yu; Chen, Pau-Chung; Wang, Jung-Der

    2014-01-01

    Herbal remedies containing aristolochic acid (AA) have been designated to be a strong carcinogen. This review summarizes major epidemiologic evidence to argue for the causal association between AA exposure and urothelial carcinoma as well as nephropathy. The exposure scenarios include the following: Belgian women taking slimming pills containing single material Guang Fang Ji, consumptions of mixtures of Chinese herbal products in the general population and patients with chronic renal failure in Taiwan, occupational exposure in Chinese herbalists, and food contamination in farming villages in valleys of the Danube River. Such an association is corroborated by detecting specific DNA adducts in the tumor tissue removed from affected patients. Preventive actions of banning such use and education to the healthcare professionals and public are necessary for the safety of herbal remedies.

  19. Exposure to slim images in mass media : television commercials as reminders of restriction in restrained eaters

    NARCIS (Netherlands)

    Anschutz, Doeschka J; van Strien, Tatjana; Engels, Rutger C M E

    OBJECTIVE: The aim of the present study was to explore the effects of exposure to slim images and diet-related products in commercials on actual food intake in relation to dietary restraint. DESIGN: An experimental design was used, in which food intake was measured in 124 female students who watched

  20. Capsule-type pe biogas digester: low-cost and environment friendly system

    International Nuclear Information System (INIS)

    Ahmad, S.; Khan, M.A.; Aslam, M.; Hussain, Z.

    2005-01-01

    The Indian model of the biogas digester has been introduced in the country during the last three decades, whereas the Chinese dome-type design could not be introduced due to the skills required for construction of this digester. The other problem associated with Chinese dome-type digester is that large quantities of solid waste are needed to fill the digester. The Chinese dome-type digester constructed on experimental basis could not perform satisfactorily. The Indian Model, although popular in the country, is not environment friendly and is of high cost, both in terms of capital investment and 0 and M. It creates quite dirty environment around the digester due to the free movement of slurry. It also creates problems of mosquitoes, as the environment. is conducive for their breeding. Taking into consideration, these limitations, design of polyethylene capsule-type digester (with black carbon and UV stabilizers) was developed, using water tanks normally constructed for domestic water storage by the local plastic companies. Modification was made in the PE water tank and one of the local companies collaborated to manufacture the capsule-type digester. Solid waste is introduced from the top, whereas the slurry can be disposed from the bottom through a controlled valve. Thus input of solid waste and slurry-disposal is now within the choice of the owner. The slurry can be disposed into a tank, where it can be composted to reduce the pH, before its use for agriculture. The PE capsule-type black-color digester is also attractive for increasing the temperature of the digester due to black body absorption. The production of gas during summer season might take a few days, whereas additional greenhouse effect during winter can raise the temperature by 10 degree C. Hence, this digester is more suitable for cooler regions where the Indian model is not successful. The design is modular in nature; therefore linking additional modules in series can increase the capacity of biogas

  1. Traditional Chinese and Indian medicine in the treatment of opioid-dependence: a review

    Directory of Open Access Journals (Sweden)

    Fatemeh Doosti

    2013-05-01

    Full Text Available Objective: In this study, the current literatures on the use of herbs and herbal preparations of Traditional Chinese and Indian Medicine for the treatment of opioid addiction were reviewed. Methods: Search was done in databases such as Pub Med, Science Direct, Scopus, Springer Link, and Google Scholar. Results: Among 18 retrieved studies, 3 studies were about asafetida extract, an approved preparation for ameliorating drug abstinence in China. Chinese preparations including Composite Dong Yuan Gao, Qingjunyin and TJ-97 (a water extract of dai-bofu-to as well as Indian ones, Mentate and Shilajit, were reported to have positive effects against opioid withdrawal, dependence, and tolerance. Moreover, Levo-tetrahydropalmatine and L-Stepholidine, in addition to extracts of Caulis Sinomenii and Sinomenium acutum showed similar effects. Banxia Houpu Decoction, Fu-Yuan pellet, Jinniu capsules, Qingjunyin, Tai-Kang-Ning capsule, and Xuan Xia Qudu Jiaonang (WeiniCom from Chinese preparations, showed anti-addiction effects in randomized, double-blind and, in some studies, multicenter clinical trials. Conclusion: Traditional herbal preparations of China and India have anti-addiction effects with less adverse effects than alpha2-adrenergic or opioid agonists.

  2. Network pharmacology-based identification of key pharmacological pathways of Yin–Huang–Qing–Fei capsule acting on chronic bronchitis

    Directory of Open Access Journals (Sweden)

    Yu GH

    2016-12-01

    Full Text Available Guohua Yu,1,2,* Yanqiong Zhang,2,* Weiqiong Ren,3 Ling Dong,1 Junfang Li,2,4 Ya Geng,2,5 Yi Zhang,2 Defeng Li,2 Haiyu Xu,2 Hongjun Yang2 1School of Chinese Materia Medica, Beijing University of Chinese Medicine, 2Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 3The First Affiliated Hospital of Hunan University of Traditional Chinese Medicine, Changsha, 4School of Chinese Materia Medica, Tianjin University of Traditional Chinese Medicine, Tianjin, 5School of Basic Medicine, Shandong University of Chinese Medicine, Jinan, China *These authors contributed equally to this work Abstract: For decades in China, the Yin–Huang–Qing–Fei capsule (YHQFC has been widely used in the treatment of chronic bronchitis, with good curative effects. Owing to the complexity of traditional Chinese herbal formulas, the pharmacological mechanism of YHQFC remains unclear. To address this problem, a network pharmacology-based strategy was proposed in this study. At first, the putative target profile of YHQFC was predicted using MedChem Studio, based on structural and functional similarities of all available YHQFC components to the known drugs obtained from the DrugBank database. Then, an interaction network was constructed using links between putative YHQFC targets and known therapeutic targets of chronic bronchitis. Following the calculation of four topological features (degree, betweenness, closeness, and coreness of each node in the network, 475 major putative targets of YHQFC and their topological importance were identified. In addition, a pathway enrichment analysis based on the Kyoto Encyclopedia of Genes and Genomes pathway database indicated that the major putative targets of YHQFC are significantly associated with various pathways involved in anti-inflammation processes, immune responses, and pathological changes caused by asthma. More interestingly, eight major putative targets of YHQFC (interleukin [IL]-3, IL-4, IL

  3. Passive sorting of capsules by deformability

    Science.gov (United States)

    Haener, Edgar; Juel, Anne

    We study passive sorting according to deformability of liquid-filled ovalbumin-alginate capsules. We present results for two sorting geometries: a straight channel with a half-cylindrical obstruction and a pinched flow fractioning device (PFF) adapted for use with capsules. In the half-cylinder device, the capsules deform as they encounter the obstruction, and travel around the half-cylinder. The distance from the capsule's centre of mass to the surface of the half-cylinder depends on deformability, and separation between capsules of different deformability is amplified by diverging streamlines in the channel expansion downstream of the obstruction. We show experimentally that capsules can be sorted according to deformability with their downstream position depending on capillary number only, and we establish the sensitivity of the device to experimental variability. In the PFF device, particles are compressed against a wall using a strong pinching flow. We show that capsule deformation increases with the intensity of the pinching flow, but that the downstream capsule position is not set by deformation in the device. However, when using the PFF device like a T-Junction, we achieve improved sorting resolution compared to the half-cylinder device.

  4. Microwave left-handed composite material made of slim ferrite rods and metallic wires

    International Nuclear Information System (INIS)

    Fang, Xu; Yang, Bai; Li-Jie, Qiao; Hong-Jie, Zhao; Ji, Zhou

    2009-01-01

    This paper reports on experimental study of the microwave properties of a composite material consisting of ferrite and copper wires. It finds that the slim ferrite rods can modify the magnetic field distribution through their anisotropy, so that the ferrite's negative influence on the copper wires' plasma will be reduced. Left-handed properties are observed even in the specimen with close stuck ferrite rods and copper wires. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  5. Magnetically guided capsule endoscopy.

    Science.gov (United States)

    Shamsudhin, Naveen; Zverev, Vladimir I; Keller, Henrik; Pane, Salvador; Egolf, Peter W; Nelson, Bradley J; Tishin, Alexander M

    2017-08-01

    Wireless capsule endoscopy (WCE) is a powerful tool for medical screening and diagnosis, where a small capsule is swallowed and moved by means of natural peristalsis and gravity through the human gastrointestinal (GI) tract. The camera-integrated capsule allows for visualization of the small intestine, a region which was previously inaccessible to classical flexible endoscopy. As a diagnostic tool, it allows to localize the sources of bleedings in the middle part of the gastrointestinal tract and to identify diseases, such as inflammatory bowel disease (Crohn's disease), polyposis syndrome, and tumors. The screening and diagnostic efficacy of the WCE, especially in the stomach region, is hampered by a variety of technical challenges like the lack of active capsular position and orientation control. Therapeutic functionality is absent in most commercial capsules, due to constraints in capsular volume and energy storage. The possibility of using body-exogenous magnetic fields to guide, orient, power, and operate the capsule and its mechanisms has led to increasing research in Magnetically Guided Capsule Endoscopy (MGCE). This work shortly reviews the history and state-of-art in WCE technology. It highlights the magnetic technologies for advancing diagnostic and therapeutic functionalities of WCE. Not restricting itself to the GI tract, the review further investigates the technological developments in magnetically guided microrobots that can navigate through the various air- and fluid-filled lumina and cavities in the body for minimally invasive medicine. © 2017 American Association of Physicists in Medicine.

  6. Probing cell internalisation mechanics with polymer capsules.

    Science.gov (United States)

    Chen, Xi; Cui, Jiwei; Ping, Yuan; Suma, Tomoya; Cavalieri, Francesca; Besford, Quinn A; Chen, George; Braunger, Julia A; Caruso, Frank

    2016-10-06

    We report polymer capsule-based probes for quantifying the pressure exerted by cells during capsule internalisation (P in ). Poly(methacrylic acid) (PMA) capsules with tuneable mechanical properties were fabricated through layer-by-layer assembly. The P in was quantified by correlating the cell-induced deformation with the ex situ osmotically induced deformation of the polymer capsules. Ultimately, we found that human monocyte-derived macrophage THP-1 cells exerted up to approximately 360 kPa on the capsules during internalisation.

  7. Governance of complex environmental situations through social learning: a synthesis of SLIM's lessons for research, policy and practice

    NARCIS (Netherlands)

    Steyaert, P.; Jiggins, Janice

    2007-01-01

    This synthesis of the SLIM project findings deals with the development and deployment of knowledge and research that is useful for actions that transform at socially and ecologically meaningful scales. A diagnostic framework (DF) is elaborated that aims to transform the findings into a tool that

  8. Domotica Smart Living. Special issue; Domotica Slim Wonden. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Lepelaars, L. [Stichting Smart Homes, eersel (Netherlands); Hamers, E. [Van Dorp Installaties, Zoetermeer (Netherlands); Van Mil, R.

    2011-10-15

    In a few articles (introduction, interview and 3 articles) attention is paid to domotica applications and smart living. The interview is with a professor 'ambient robotics' at the University of Amsterdam. The articles are about (1) the activities of the Smart Homes Foundation, (2) the use of domotica in the health and homecare sector, and (3) the use of domotica to improve comfort, safety and efficiency. [Dutch] In een paar artikelen (voorwoord, interview en 3 artikelen) wordt aandacht besteed aan domotica toepassingen en slim wonen. Het interview betreft een bijzonder hoogleraar 'ambient robotics aan de Universiteit van Amsterdam. De artikelen gaan over de activiteiten van de Stichting Smart Homes, (2) de toepassingen van domotica in de thuiszorg, en (3) het gebruik van domotica om het comfort, de veiligheid en energie efficiency te verbeteren.

  9. Integrated identification, qualification and quantification strategy for pharmacokinetic profile study of Guizhi Fuling capsule in healthy volunteers

    OpenAIRE

    Yun-Xi Zhong; Xiao-Liang Jin; Shi-Yin Gu; Ying Peng; Ke-Rong Zhang; Bing-Chen Ou-Yang; Yu Wang; Wei Xiao; Zhen-Zhong Wang; Ji-Ye Aa; Guang-Ji Wang; Jian-Guo Sun

    2016-01-01

    Guizhi Fuling capsule (GZFL), a traditional Chinese medicine formulation, is widely used in China to relieve pain from dysmenorrhea and is now in a Phase II clinical trial in the USA. Due to the low exposure of the five main medicative ingredients (amygdalin, cinnamic acid, gallic acid, paeoniflorin and paeonol) of GZFL in human, a strategy was built to qualitatively and quantitatively identify the possible metabolites of GZFL and to describe the pharmacokinetic profiles of GZFL in human. In ...

  10. Status of irradiation capsule design

    International Nuclear Information System (INIS)

    Nagata, Hiroshi; Yamaura, Takayuki; Nagao, Yoshiharu

    2013-01-01

    For the irradiation test after the restart of JMTR, further precise temperature control and temperature prediction are required. In the design of irradiation capsule, particularly sophisticated irradiation temperature prediction and evaluation are urged. Under such circumstance, among the conventional design techniques of irradiation capsule, the authors reviewed the evaluation method of irradiation temperature. In addition, for the improvement of use convenience, this study examined and improved FINAS/STAR code in order to adopt the new calculation code that enables a variety of analyses. In addition, the study on the common use of the components for radiation capsule enabled the shortening of design period. After the restart, the authors will apply this improved calculation code to the design of irradiation capsule. (A.O.)

  11. Simultaneous Determination of Ten Constituents in Chaiqin Qingning Capsule by High-performance Liquid Chromatography Coupled with Triple-quadrupole Mass Spectrometry.

    Science.gov (United States)

    Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu

    2017-01-01

    Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass spectrometry Chaiqin Qingning Capsules; HPLC-MS/MS: High liquid

  12. Simultaneous Determination of Ten Constituents in Chaiqin Qingning Capsule by High-performance Liquid Chromatography Coupled with Triple-quadrupole Mass Spectrometry

    Science.gov (United States)

    Li, Ting Yu; Huo, Xiao Kui; Zheng, Lu; Wang, Chao; Cong, Hai Jian; Xiang, Ting; Zhang, Lin; Zhang, Bao Jing; Huang, Shan Shan; Wu, Bin; Li, Xin Yu

    2017-01-01

    Background: Chaiqin Qingning Capsule (CQQNC) was a prescription of Traditional Chinese Medicine with the effects of clearing away heat and removing toxin, harmonizing the exterior and interior, it was widely used in Asian, for example, China and Japan, different batches of the raws materials and different processing time may be the vital factor which raised a challenge to control the quality of the CQQNC. Experimental Methods: In this experiment, a high-performance liquid chromatography-mass spectrometry/MS (HPLC-MS/MS) method was developed to simultaneously determine ten bioactive components for the quality control of CQQNC. Chromatographic separation was achieved using an XBridge BEH C18 column (150 mm × 4.6 mm, 2.5 μm) with a mobile phase composed of 10 mm aqueous ammonium acetate and acetonitrile using a gradient elution in 20 min. This study was conducted by multiple reaction monitoring mode through electrospray ionization resource with a negative ionization mode. Results: The established method was validated with good performance of precision, accuracy, stability, and reproducibility and was utilized to simultaneously quantify ten constituents of CQQNC obtained from seven different batches. Conclusion: It is the first time to report the rapid and simultaneous analysis of the ten compounds in CQQNC by HPLC-MS/MS and apply to determine 10 constituents in 7 batches of CQQNC bought from drug store in china. This method could be considered as good quality criteria to control the quality of CQQNC. SUMMARY In this paper, a simple, specific, and rapid high-performance liquid chromatogram coupled with triple-quadrupole mass spectrometry method for simultaneous quantification of ten constituents in Chaiqin Qingning Capsule has been developed for the first time. This method could be considered as good quality criteria to control the quality of CQQNC. Abbreviations used: CHM: Chinese herbal medicine; TCM: Traditional Chinese Medicine; CQQNC: Triple-quadrupole mass

  13. Intrauterine fertilization capsules--a clinical trial

    DEFF Research Database (Denmark)

    Lenz, S; Lindenberg, S; Sundberg, K

    1991-01-01

    Treatment of 26 women with tubal infertility was attempted using intrauterine capsules loaded with oocytes and spermatozoa. The stimulation protocol was as used for in vitro fertilization and embryo transfer and consisted of short-term use of Buserelin, human menopausal gonadotropin, and human...... and piston from an intrauterine device. Six complete capsules and parts of two other capsules were expelled. None of the women became pregnant, compared with a pregnancy rate of 21% per aspiration following in vitro fertilization and embryo transfer during the same period....... chorionic gonadotropin. Oocytes were collected by ultrasonically guided transvaginal aspiration, and spermatozoa were prepared by swim-up technique. The gametes were placed in agar capsules 4 hr after oocyte collection, and the capsules were introduced to the uterine fundus using an insertion tube...

  14. [Longjintonglin Capsules for type IIIA prostatitis accompanied by abnormal semen liquefaction: A clinical observation].

    Science.gov (United States)

    Cai, Hong-cai; Wan, Chang-chun; Geng, Qiang; Liu, Wei; Zhang, Guo-wei; Shang, Xue-jun; Huang, Yu-feng

    2016-01-01

    To evaluate the therapeutic effect of Longjintonglin Capsules on type IIIA prostatitis accompanied by abnormal semen liquefaction. We selected 140 patients with type IIIA prostatitis accompanied by abnormal semen liquefaction according to the diagnostic standards of the American Institutes of Health (NIH) and treated them with Longjintonglin Capsules orally 3 capsules once tid for 12 weeks. We obtained the NIH Chronic Prostatitis Symptom Indexes (NIH-CPSI), traditional Chinese medicine (TCM) syndrome scores, leukocyte count in the expressed prostatic secretion (EPS), semen liquefaction time, and the results of semen analysis and compared these indicators before and after the treatment. Of the 140 cases, 132 were included in this study, excluding 8 due to their incomplete case histories. Before and after 4, 8 and 12 weeks of medication, the total NIH-CPSI scores were 24.52 ± 5.43, 21.28 ± 4.85, 18.01 ± 4.28, and 14.49 ± 3.65 (P prostatitis were cured and another 72 well responded, with an overall response rate of 78.0%. Of those with abnormal semen liquefaction, 61 were cured, 39 well responded, and 32 failed to respond, with an overall effectiveness rate of 75.8%. Semen analysis showed significantly increased percentage of progressively motile sperm after 4, 8 and 12 weeks of medication as compared with the baseline (P prostatitis accompanied by abnormal semen liquefaction.

  15. High-speed precision weighing of pharmaceutical capsules

    International Nuclear Information System (INIS)

    Bürmen, Miran; Pernuš, Franjo; Likar, Boštjan

    2009-01-01

    In this paper, we present a cost-effective method for fast and accurate in-line weighing of hard gelatin capsules based on the optimized capacitance sensor and real-time processing of the capsule capacitance profile resulting from 5000 capacitance measurements per second. First, the effect of the shape and size of the capacitive sensor on the sensitivity and stability of the measurements was investigated in order to optimize the performance of the system. The method was tested on two types of hard gelatin capsules weighing from 50 mg to 650 mg. The results showed that the capacitance profile was exceptionally well correlated with the capsule weight with the correlation coefficient exceeding 0.999. The mean precision of the measurements was in the range from 1 mg to 3 mg, depending on the size of the capsule and was significantly lower than the 5% weight tolerances usually used by the pharmaceutical industry. Therefore, the method was found feasible for weighing pharmaceutical hard gelatin capsules as long as certain conditions are met regarding the capsule fill properties and environment stability. The proposed measurement system can be calibrated by using only two or three sets of capsules with known weight. However, for most applications it is sufficient to use only empty and nominally filled capsules for calibration. Finally, a practical application of the proposed method showed that a single system is capable of weighing around 75 000 capsules per hour, while using multiple systems could easily increase the inspection rate to meet almost any requirements

  16. Thermoregulation of Capsule Production by Streptococcus pyogenes

    Science.gov (United States)

    Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong

    2012-01-01

    The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992

  17. NIF capsule performance modeling

    Directory of Open Access Journals (Sweden)

    Weber S.

    2013-11-01

    Full Text Available Post-shot modeling of NIF capsule implosions was performed in order to validate our physical and numerical models. Cryogenic layered target implosions and experiments with surrogate targets produce an abundance of capsule performance data including implosion velocity, remaining ablator mass, times of peak x-ray and neutron emission, core image size, core symmetry, neutron yield, and x-ray spectra. We have attempted to match the integrated data set with capsule-only simulations by adjusting the drive and other physics parameters within expected uncertainties. The simulations include interface roughness, time-dependent symmetry, and a model of mix. We were able to match many of the measured performance parameters for a selection of shots.

  18. DC-Link Compensation Method for Slim DC Link Drives Fed by Soft Grid

    DEFF Research Database (Denmark)

    Mathe, Laszlo; Rosendahl Andersen, Henrik; Lazar, Radu

    2010-01-01

    Slim DC-link PWM (AC) drives for lowperformance applications are emerging on the market. Such drives equipped with a small DC-link capacitance exhibit instability tendencies, if installed on a soft line, giving a degraded performance. The total harmonic distortion (THD) and the partially weighted...... harmonic distortion (PWHD) of the line current are degraded, if resonance between the line impedance and the DC-link capacitance occurs. Likewise, the motor performance is affected negatively giving extra torque ripple, vibration and acoustic-noise emission. This paper proposes a novel DC-link compensation...

  19. Treatment of rats with Jiangzhi Capsule improves liquid fructose-induced fatty liver: modulation of hepatic expression of SREBP-1c and DGAT-2.

    Science.gov (United States)

    Zhao, Yuanyang; Pan, Yongquan; Yang, Yifan; Batey, Robert; Wang, Jianwei; Li, Yuhao

    2015-06-02

    Jiangzhi Capsule is an Australian listed patented traditional Chinese medicine and has been used for management of lipid abnormalities over the past 10 years. To obtain a better understanding regarding Jiangzhi Capsule, the present study investigated the effects and underlying mechanisms of Jiangzhi Capsule on chronic fructose overconsumption-induced lipid abnormalities. Male rats were treated with liquid fructose in their drinking water over 14 weeks. Jiangzhi Capsule was co-administered (once daily, by oral gavage) during the last 7 weeks. Indexes of lipid and glucose homeostasis were determined enzymatically, by ELISA and/or histologically. Gene expression was analyzed by real-time PCR, Western blot and/or immunohistochemistry. Treatment with Jiangzhi Capsule (100 mg/kg) attenuated fructose-induced excessive triglyceride accumulation and Oil Red O-stained area in the liver. This effect was accompanied by amelioration of hyperinsulinemia. There was no significant difference in intakes of fructose and chow, and body weight between fructose control and fructose Jiangzhi Capsule-treated groups. Mechanistically, Jiangzhi Capsule downregulated fructose-stimulated hepatic overexpression of sterol regulatory element binding protein (SREBP)-1/1c at the mRNA and protein levels. Accordingly, the SREBP-1c downstream genes, acetyl-CoA carboxylase-1 and stearoyl-CoA desaturase-1, were also inhibited. In addition, acyl-coenzyme A:diacylglycerol acyltransferase (DGAT)-2 expression at the mRNA and protein levels in the liver was also inhibited after Jiangzhi Capsule treatment. In contrast, Jiangzhi Capsule affected neither carbohydrate response element binding protein, peroxisome proliferator-activated receptor (PPAR)-gamma and DGAT-1, nor PPAR-alpha and its target genes. These findings demonstrate the anti-steatotic action of Jiangzhi Capsule in fructose-fed rats, and modulation of hepatic SREBP-1c and DGAT-2 involved in hepatic de novo synthesis of fatty acids and triglyceride

  20. Herniation of the anterior lens capsule

    Directory of Open Access Journals (Sweden)

    Pereira Nolette

    2007-01-01

    Full Text Available Herniation of the anterior lens capsule is a rare abnormality in which the capsule bulges forward in the pupillary area. This herniation can be mistaken for an anterior lenticonus where both the capsule and the cortex bulge forward. The exact pathology behind this finding is still unclear. We report the clinical, ultrasound biomicroscopy (UBM and histopathological findings of a case of herniation of the anterior lens capsule. UBM helped to differentiate this entity from anterior lenticonus. Light microscopy revealed capsular splitting suggestive of capsular delamination and collection of fluid (aqueous in the area of herniation giving it a characteristic appearance.

  1. Diagnostic and therapeutic radio pharmaceutical capsules

    International Nuclear Information System (INIS)

    Haney, T.A.; Wedeking, P.W.; Morcos, N.A.

    1981-01-01

    An improved pharmaceutical radioactive capsule consisting of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contact with fluids of the gastro-intestinal tract is described. Each capsule is provided with filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract. The capsule is preferably of gelatin, methyl cellulose or polyvinyl alcohol and the filler is a polyethylene glycol. The radioactive compound may be iodine e.g. sodium radioiodide I-131 or 123. The capsule may also contain a reducing agent e.g. sodium thiosulphate, sulphite, or bisulphite. (author)

  2. Rapid Surface Enhanced Raman Scattering (SERS Detection of Sibutramine Hydrochloride in Pharmaceutical Capsules with a β-Cyclodextrin- Ag/Polyvivnyl Alcohol Hydrogel Substrate

    Directory of Open Access Journals (Sweden)

    Lei Ouyang

    2017-07-01

    Full Text Available Sibutramine hydrochloride (SH is a banned weight-loss drug, but its illegal addition to health products is still rampant. This suggests a very urgent need for a fast and precise detection method for SH. Surface Enhanced Raman Scattering (SERS is a promising candidate for this purpose, but the weak affinity between SH and bare metal limits its direct SERS detection. In the present work, β-cyclodextrin was capped in situ onto the surface of Ag nanoparticles to function as a scaffold to capture SH. The obtained Ag nanoparticles were encapsulated into polyvinyl alcohol (PVA to fabricate a SERS active hydrogel with excellent reproducibility. A facile SERS strategy based on such substrate was proposed for trace SH quantification with a linear range of 7.0–150.0 µg·mL–1, and a detection limit low to 3.0 µg·mL−1. It was applied to analyze seven types of commercial slimming capsules with satisfactory results, showing good prospect for real applications.

  3. Increasing Z-pinch vacuum hohlraum capsule coupling efficiency

    International Nuclear Information System (INIS)

    Callahan, Debbie; Vesey, Roger Alan; Cochrane, Kyle Robert; Nikroo, A.; Bennett, Guy R.; Schroen, Diana Grace; Ruggles, Laurence E.; Porter, John L.; Streit, Jon; Mehlhorn, Thomas Alan; Cuneo, Michael Edward

    2004-01-01

    Symmetric capsule implosions in the double-ended vacuum hohlraum (DEH) on Z have demonstrated convergence ratios of 14-21 for 2.15-mm plastic ablator capsules absorbing 5-7 kJ of x-rays, based on backlit images of the compressed ablator remaining at peak convergence (1). Experiments with DD-filled 3.3-mm diameter capsules designed to absorb 14 kJ of x-rays have begun as an integrated test of drive temperature and symmetry, complementary to thin-shell symmetry diagnostic capsules. These capsule implosions are characterized by excellent control of symmetry (< 3% time-integrated), but low hohlraum efficiency (< 2%). Possible methods to increase the capsule absorbed energy in the DEH include mixed-component hohlraums, large diameter foam ablator capsules, transmissive shine shields between the z-pinch and capsule, higher spoke electrode x-ray transmission, a double-sided power feed, and smaller initial radius z-pinch wire arrays. Simulations will explore the potential for each of these modifications to increase the capsule coupling efficiency for near-term experiments on Z and ZR

  4. 21 CFR 520.1660b - Oxytetracycline hydrochloride capsules.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride capsules. 520.1660b... Oxytetracycline hydrochloride capsules. (a) Specifications. The drug is in capsule form with each capsule containing 125 or 250 milligrams of oxytetracycline hydrochloride. Oxytetracycline is the antibiotic...

  5. Thermal characteristic test for saturated temperature type capsule

    International Nuclear Information System (INIS)

    Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki; Ohuchi, Mitsuo; Harayama, Yasuo

    1989-08-01

    The Japan Material Testing Reactor Project is developing a new type capsule so-called 'Saturated Temperature Capsule', as a part of irradiation technique improvement program. This type capsule, in which the water is supplied and boiled, bases on the conception of keeping the coolant at the saturated temperature and facilitating the temperature setting of specimens heated by gamma-ray in reactor. However, out-pile test was planned, because there were few usable data for design and operation of the capsule into which the coolant was injected. A out-pile apparatus, simulated the capsule with electric heaters, was fabricated and experiments were carried out, to obtain data concerning design and operation for the capsule into which the water was injected. As a structure of simulated capsule, a type of downward coolant supply was adopted. The downward coolant tube type injectes the water in the bottom of capsule by tube through the upper flange. Major objects of experiences were to grasp thermal features under operation and to provide performances of capsule control equipment. Experimental results proved that the temperature of water within the capsule was easily varied by controlling supply water flow rate, and that the control equipment was operated stably and safety. (author)

  6. Health discourses, slimness ideals and attitudes to physical activities

    DEFF Research Database (Denmark)

    Pfister, Gertrud Ursula; With-Nielsen, Ninna; Lenneis, Verena

    2017-01-01

    Studies conducted in Denmark reveal that many young women drop out of sport and exercise in their teenage years even though they possess good knowledge about health recommendations and the benefits of physical activity. This raises the question as to how they interpret and make use of the current...... messages about a healthy and active lifestyle. Based on five focus-group interviews and a survey among 784 female students aged 16-20, we explored their attitudes and practices with regard to physical activity and health. The analysis of the material is theoretically informed by the work of Foucauldian...... scholars who have used the concepts of governmentality and disciplinary power to explore current public health policies and young people’s health-related attitudes and practices. We found that for the participants in our study ‘health’ was inextricably intertwined with slimness and fitness, to which...

  7. Capsule safety analysis of PRTF irradiation facility

    International Nuclear Information System (INIS)

    Suwarto

    2013-01-01

    Power Ramp Test Facility (PRTF) is an irradiation facility used for fuel testing of power reactor. PRTF has a capsule which is a test fuel rod container. During operation, pressurized water of 160 bars flows through in the capsule. Due to the high pressure it should be analyzed the impact of the capsule on reactor core safety. This analysis has purpose to calculate the ability of capsule pressure capacity. The analysis was carried out by calculating pressure capacity. From the calculating results it can be concluded that the capsule with pressure capacity of 438 bars will be safe to prevent the operation pressure of PRTF. (author)

  8. Slimness is associated with greater intercourse and lesser masturbation frequency.

    Science.gov (United States)

    Brody, Stuart

    2004-01-01

    I examined the relationship of recalled and diary recorded frequency of penile-vaginal intercourse (FSI), noncoital partnered sexual activity, and masturbation to measured waist and hip circumference in 120 healthy adults aged 19-38. Slimmer waist (in men and in the sexes combined) and slimmer hips (in men and women) were associated with greater FSI. Slimmer waist and hips were associated with rated importance of intercourse for men. Noncoital partnered sexual activity had a less consistent association with slimness. Slimmer waist and hips were associated with less masturbation (in men and in the sexes combined). I discuss the results in terms of differences between different sexual behaviors, attractiveness, emotional relatedness, physical sensitivity, sexual dysfunction, sociobiology, psychopharmacological aspects of excess fat and carbohydrate consumption, and implications for sex therapy.

  9. Adhesive capsulitis of the shoulder: MR arthrography

    International Nuclear Information System (INIS)

    Kim, Hyun Jeong; Han, Tae Il; Lee, Kwang Won; Choi, Youn Seon; Kim, Dae Hong; Han, Hyun Young; Song, Mun Kab; Kwon, Soon Tae

    2001-01-01

    Adhesive capsulitis is a clinical syndrome involving pain and decreased joint motion caused by thickening and contraction of the joint capsule. The purpose of this study is to describe the MR arthrographic findings of this syndrome. Twenty-nine sets of MR arthrographic images were included in the study. Fourteen patients had adhesive capsulitis diagnosed by physical examination and arthrography, and their MR arthrographic findings were compared with those of 15 subjects in the control group. The images were retrospectively reviewed with specific attention to the thickness of the joint capsule, volume of the axillary pouch (length, width, height(depth)), thinkness of the coracohumeral ligament, presence of extra-articular contrast extravasation, and contrst filling of the subcoracoid bursa. Mean capsular thickness measured at the inferior portion of the axillary pouch was 4.1 mm in patients with adhesive capsulitis and 1.5 mm in the control group. The mean width of the axillary pouch was 2.5 mm in patients and 9.5 mm in controls. In patients, the capsule was significantly thicker and the axillary pouch significantly narrower than in controls (p<0.05). Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch (sensitivity 93%, specificity 80%) and a pouch narrower than 3.5 mm (sensitivity 93%, specificity 100%) were useful criteria for the diagnosis of adhesive capsulitis. In patients with this condition, extra-articular contrast extravasation was noted in six patients (43%) and contrast filling of the subcoracoid bursa in three (21%). The MR arthrographic findings of adhesive capsulitis are capsular thickening, a low-volume axillary pouch, extra-articular contrast extravasation, and contrast filling of the subcoracoid bursa. Capsule thickness greater than 2.5 mm at the inferior portion of the axillary pouch and a pouch width of less than 3.5 mm are useful diagnostic imaging characteristics

  10. [Current research situation of nephrotoxicity of Chinese herbal medicine].

    Science.gov (United States)

    Feng, Xue; Fang, Sai-Nan; Gao, Yu-Xin; Liu, Jian-Ping; Chen, Wei

    2018-02-01

    To provide the basis for the future research on the nephrotoxicity of Chinese herbal medicine through systematic and comprehensive summary of all the Chinese herbal medicines which may lead to nephrotoxicity. Foreign resources included PubMed and Cochrane library, and domestic research resources was China Food and Drug Administration(CDFA) Adverse Drug Reaction Monitoring Center database. The databases were searched from establishment to January 1, 2017. There was no limitation on research type. 28 English studies were found, including 97 Chinese herbs or prescriptions with the risk of nephrotoxicity. The following six Chinese herbal medicines with the risk of nephrotoxicity had a large number of studies: aristolochic acid(5 studies), Tripterygium wilfordii(4 studies), Erycibe obtusifolia(2 studies), Rheum palmatum(2 studies), Ephedra sinica(2 studies), and Atractylodes lances(2 studies). The remaining 91 Chinese medicines were reported with risk of nephrotoxicity in only 1 study respectively. CDFA reported 16 Chinese herbal medicines with the risk of nephrotoxicity, including Ganmaoqing Pian(capsule), Zhenju Jiangya Pian, T. wilfordii preparation, Vc-Yinqiao Pian, Chuanhuning injection, Shuanghuanglian injection, Qingkailing injection, Lianbizhi injection, herbal decoction containing Aristolochiae Radix, Guanxin Suhe Wan, Shugan Liqi Wan, Ershiwuwei Songshi Wan, herbal decoction containing Aristolochia Fangchi, herbal granules containing root of Kaempfer Dutchmanspipe, Ganmaotong(tablets), and Longdan Xiegan Wan. Currently, in addition to aristolochic acids, the most reported Chinese herbal medicine with the risk of nephrotoxicity is T. wilfordii preparation. Copyright© by the Chinese Pharmaceutical Association.

  11. Reinforcing effects of caffeine in coffee and capsules.

    Science.gov (United States)

    Griffiths, R R; Bigelow, G E; Liebson, I A

    1989-09-01

    In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.

  12. A New Family of Capsule Polymerases Generates Teichoic Acid-Like Capsule Polymers in Gram-Negative Pathogens.

    Science.gov (United States)

    Litschko, Christa; Oldrini, Davide; Budde, Insa; Berger, Monika; Meens, Jochen; Gerardy-Schahn, Rita; Berti, Francesco; Schubert, Mario; Fiebig, Timm

    2018-05-29

    Group 2 capsule polymers represent crucial virulence factors of Gram-negative pathogenic bacteria. They are synthesized by enzymes called capsule polymerases. In this report, we describe a new family of polymerases that combine glycosyltransferase and hexose- and polyol-phosphate transferase activity to generate complex poly(oligosaccharide phosphate) and poly(glycosylpolyol phosphate) polymers, the latter of which display similarity to wall teichoic acid (WTA), a cell wall component of Gram-positive bacteria. Using modeling and multiple-sequence alignment, we showed homology between the predicted polymerase domains and WTA type I biosynthesis enzymes, creating a link between Gram-negative and Gram-positive cell wall biosynthesis processes. The polymerases of the new family are highly abundant and found in a variety of capsule-expressing pathogens such as Neisseria meningitidis , Actinobacillus pleuropneumoniae , Haemophilus influenzae , Bibersteinia trehalosi , and Escherichia coli with both human and animal hosts. Five representative candidates were purified, their activities were confirmed using nuclear magnetic resonance (NMR) spectroscopy, and their predicted folds were validated by site-directed mutagenesis. IMPORTANCE Bacterial capsules play an important role in the interaction between a pathogen and the immune system of its host. During the last decade, capsule polymerases have become attractive tools for the production of capsule polymers applied as antigens in glycoconjugate vaccine formulations. Conventional production of glycoconjugate vaccines requires the cultivation of the pathogen and thus the highest biosafety standards, leading to tremendous costs. With regard to animal husbandry, where vaccines could avoid the extensive use of antibiotics, conventional production is not sufficiently cost-effective. In contrast, enzymatic synthesis of capsule polymers is pathogen-free and fast, offers high stereo- and regioselectivity, and works with high efficacy

  13. Oxygen fugacity and piston cylinder capsule assemblies

    Science.gov (United States)

    Jakobsson, S.

    2011-12-01

    A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)

  14. Isolation and structural characterization of a novel sibutramine analogue, chlorosipentramine, in a slimming dietary supplement, by using HPLC-PDA, LC-Q-TOF/MS, FT-IR, and NMR.

    Science.gov (United States)

    Yun, Jisuk; Shin, Kye Jung; Choi, Jangduck; Jo, Cheon-Ho

    2018-05-01

    A novel sibutramine analogue was detected in a slimming formula by high performance liquid chromatography with a photo diode detector array (HPLC-PDA). The unknown compound exhibited an ultraviolet (UV) spectrum that was similar to that of chlorosibutramine, despite having a different HPLC retention time. Further analysis of the slimming formula by LC-quadrupole time-of-flight mass spectrometry (LC-Q-TOF/MS) showed that the unknown compound had the formula C 18 H 27 Cl 2 N. To elucidate the structure of this new sibutramine analogue, the target compound in the slimming formula was isolated on a preparative-LC system equipped with a PDA. After analysis by fourier transform infrared (FT-IR) and nuclear magnetic resonance (NMR) spectroscopy, the unknown compound was identified as a sibutramine analogue in which the iso-butyl group on the side chain is replaced with an iso-pentyl group. This new sibutramine analogue was identified to be 1-(1-(3,4-dichlorophenyl)cyclobutyl)-N,N,4-trimethylpentan-1-amine and has been named as chlorosipentramine. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. 2,4-Dinitrophenol: A threat to Chinese body-conscious groups

    Directory of Open Access Journals (Sweden)

    Han Chih Hencher Lee

    2014-08-01

    Full Text Available 2,4-Dinitrophenol (2,4-DNP, a yellowish compound, has historically been used in the manufacture of dyes, explosives, and fungicides. As it uncouples mitochondrial oxidative phosphorylation, the compound was also used as an antiobesity agent early in the past century. The compound was subsequently banned by the United States Food and Drug Administration in 1938 due to its potentially fatal adverse effects, including hyperthermia, cataract, agranulocytosis, hepatoxicity, nephrotoxicity, and cardiotoxicity. However, the popularity of 2,4-DNP as a slimming aid has appeared to increase again in recent years. The Hong Kong Hospital Authority Toxicology Reference Laboratory recently confirmed two cases of self-administered 2,4-DNP with different clinical presentations to hospitals in the area. Here we describe those two cases, in an attempt to underscore the potential of misuse of this substance by body-conscious groups among the Chinese population.

  16. Vortex rings from Sphagnum moss capsules

    Science.gov (United States)

    Whitaker, Dwight; Strassman, Sam; Cha, Jung; Chang, Emily; Guo, Xinyi; Edwards, Joan

    2010-11-01

    The capsules of Sphagnum moss use vortex rings to disperse spores to suitable habitats many kilometers away. Vortex rings are created by the sudden release of pressurized air when the capsule ruptures, and are an efficient way to carry the small spores with low terminal velocities to heights where they can be carried by turbulent wind currents. We will present our computational model of these explosions, which are carried out using a 2-D large eddy simulation (LES) on FLUENT. Our simulations can reproduce the observed motion of the spore clouds observed from moss capsules with high-speed videos, and we will discuss the roles of bursting pressure, cap mass, and capsule morphology on the formation and quality of vortex rings created by this plant.

  17. [Evaluation of nopal capsules in diabetes mellitus].

    Science.gov (United States)

    Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R

    1992-01-01

    To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.

  18. Pixel Sensors with slim edges and small pitches for the CMS upgrades for HL-LHC

    CERN Document Server

    AUTHOR|(CDS)2084134; Bolla, Gino; Rivera, Ryan Allen; Uplegger, Lorenzo; Zoi, Irene

    2016-01-01

    Planar n-in-n silicon detectors with small pitches and slim edges are being investigated for the innermost layers of tracking devices for the foreseen upgrades of the LHC. Sensor prototypes compatible with the CMS readout, fabricated by Sintef, were tested in the laboratory and with a 120~GeV/c proton beam at the Fermilab test beam facility before and after irradiation with up to 2x10$^{15}$ n$_{eq}/$cm$^2$ fluence. Preliminary results of the data analysis are presented.

  19. Design and fabrication of non-instrumented capsule

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility.

  20. Design and fabrication of non-instrumented capsule

    International Nuclear Information System (INIS)

    Kim, Yong Sung; Lee, Jeong Young; Kim, Joon Yeon; Lee, Sung Ho; Ji, Dae Young; Kim, Suk Hoon; Ahn, Sung Ho

    1995-04-01

    The use of non-instrumented capsule designed and fabricated in this time is for the evaluation of material irradiation performance, it is to be installed in the inner core of HANARO. The design process of non-instrumented capsule was accomplished by the decision of the quality of material and the shape, thermal analysis, structural analysis. The temperature of the specimen and the stress in capsule during irradiation test was calculated by the thermal analysis and the structural analysis. GGENGTC code and ABAQUS code were used for the calculation of non-instrumented capsule. In case of installing the capsule in irradiation hole, the coolant flow rate and the pressure drop in the hole is changed, which will affect the coolant flow rate of the fuel region. Eventually the coolant flow rate outside capsule have to be restricted to the allowable range. In order to obtain the required pressure drop, the flow rate control mechanism, end plate and orifice ring were used in this test. The test results are compared with 36-element fuel pressure drop data which AECL performed by the SCTR facility

  1. Effect of Smilax China Capsules and azithromycin combined therapy on chronic annexitis

    Directory of Open Access Journals (Sweden)

    Rong-Jun Cong

    2016-11-01

    Full Text Available Objective: To explore the mechanism of Smilax China (Chinese spelling: Jingangteng Capsules and Azithromycin combined therapy for chronic annexitis, and offer help to patients with chronic annexitis on relevant clinical therapies. Methods: A total of 170 cases of patients with chronic annexitis were selected from the gynecological department in our hospital, and randomly divided to be the combination therapy group and the control group by digital table, 85 cases for each group. Patients in control group were treated with Azithromycin. Patients in combination therapy group were treated by giving Smilax China capsules based on the Azithromycin treatment. Relevant indexes of lymphocyte subsets (CD3+ , CD4+ , CD8+ and CD4+ /CD8+ , cytokines (TNF-α, IL-2, IL-6 and IL-10 and hemorheology (blood viscosity, plasma viscosity, hematocrit, red blood cell aggregation index in patients of the two groups were detected before and after treatment. Results: Before treatment, no statistical significance found on the differences of lymphocyte subsets, cytokines and hemorheology between the two groups of patients (P>0.05; After treatment received on the two groups of patients, indexes of CD3+ , CD4+ and CD4+ /CD8+ were dramatically increased, CD8+ , cytokines (TNF-α, IL-2, IL-6 and IL-10 and hemorheology in the combination therapy group were significantly decreased compared with patients in the control group; Statistical significance existed in differences between the two groups (P<0.05. Conclusions: Patients who received Azithromycin therapy added with Smilax China capsules concurrently could be significantly improved levels of lymphocyte subsets, cytokines and hemorheology index. It is of clinical importance for treatment of patients with chronic annexitis.

  2. Evolutionary enhancement of the SLIM-MAUD method of estimating human error rates

    International Nuclear Information System (INIS)

    Zamanali, J.H.; Hubbard, F.R.; Mosleh, A.; Waller, M.A.

    1992-01-01

    The methodology described in this paper assigns plant-specific dynamic human error rates (HERs) for individual plant examinations based on procedural difficulty, on configuration features, and on the time available to perform the action. This methodology is an evolutionary improvement of the success likelihood index methodology (SLIM-MAUD) for use in systemic scenarios. It is based on the assumption that the HER in a particular situation depends of the combined effects of a comprehensive set of performance-shaping factors (PSFs) that influence the operator's ability to perform the action successfully. The PSFs relate the details of the systemic scenario in which the action must be performed according to the operator's psychological and cognitive condition

  3. Systematic review and meta-analysis of the efficacy and safety of Biqi capsule in rheumatoid arthritis patients.

    Science.gov (United States)

    Chen, Xiu-Min; Wu, Jia-Qi; Huang, Qing-Chun; Zhang, Jian-Yong; Pen, Jian-Hong; Huang, Zhi-Sheng; Chu, Yong-Liang; He, Xiao-Hong; Wang, Mao-Jie; Huang, Run-Yue

    2018-06-01

    Biqi capsule is a Traditional Chinese Medicine preparation for treating rheumatoid arthritis (RA), and clinical studies have indicatedthat its effect may be more beneficial than that of Western medicine. The present study aimed to estimate the efficacy and safety of Biqi capsule alone or combined with methotrexate (MTX) compared with MTX alone for treating RA by performing a meta-analysis of randomized controlled trials and controlled clinical trials. A systematic literature search of studies published until March 2017 was performed. References from relevant studies were screened to obtain additional articles. The results were independently evaluated for relevance, and full-text studies were assessed for eligibility. The risk of bias was assessed using the Cochrane collaboration tool for assessing risk of bias. Out of 558 citations that were initially retrieved, a total of 5 studies comprising 522 patients met the inclusion criteria. The risk of bias of these trials was generally unclear or high. Meta-analysis indicated that Biqi capsule had better effects on C-reactive protein [standardized mean difference (SMD), -7.05; 95% CI -(10.77-3.33)] and tender joint count [SMD, -3.02; 95% CI, -(3.81-2.22)] and fewer adverse effects (AEs) than MTX [relative risk (RR), 0.19; 95% CI, 0.08-0.43]. Biqi capsule plus MTX was superior to MTX in terms of the total effect (RR, 1.17; 95% CI, 1.06-1.28), rheumatoid factor [SMD, -12.54; 95% CI, -(16.87-8.20)], swollen joint count [SMD, -1.50; 95% CI, -(1.99-1.01)], score of joint swelling [SMD -2.07; 95% CI, -(2.76-1.38)], tender joint count [SMD, -2.16; 95% CI, -(2.86-1.47)] and score of joint tenderness [SMD, -4.69; 95% CI, -(5.92-3.47)]. There was no difference in AEs between Biqi capsule plus MTX and MTX (RR, 0.71; 95% CI, 0.34-1.50). In conclusion, the present study indicated that compared with MTX, Biqi capsule plus MTX appeared to have more benefits but that Biqi capsule alone was not better for RA patients than MTX. In the

  4. Food, nutrition and slimming messages in British women's magazines, 1950-1998.

    Science.gov (United States)

    Barker, M E; McNeir, K; Sameer, S; Russell, J

    2014-04-01

    The present study examined temporality in the representation of food in two popular British women's magazines between 1950 and 1998. A quantitative content analysis of (i) prevalence of cooking, slimming, nutrition advice in articles; (ii) prevalence of food advertising by food type; and (iii) likelihood of various nutrition and consumer messages in advertising was performed on a sample comprising 200 magazines, with 3045 advertisements and 88 articles. The prevalence of food advertisements decreased (P < 0.001), whereas food articles increased, across decades (P < 0.001). Cooking tips dominated 1950s food writing (100%), contrasting with miniscule coverage in the 1990s (5%). Slimming advice was not represented in 1950s articles and was most common in 1970s articles (55% of articles). Food advertising for all food types decreased in the 1990s decade. There were greater bread and cereals (P < 0.001), protein foods (P = 0.001) and dairy (P < 0.001) advertising in later decades; advertising for sugar- and fat-rich foods (P < 0.001), condiments and baking ingredients (P < 0.001) and beverages (P < 0.001) was greater in earlier decades. Odds of advertising claims for energy, easy digestion, nourishment, general health, economy, good for family (all P < 0.01), pleased others (P = 0.017) and convenience (P = 0.031) were greater in the 1950s and decreased thereafter. Claims around taste and quality were highest in the 1960s (all P < 0.01). Mineral, additive-free, and protein claims were most likely to be invoked in 1970s advertising (all P < 0.01). Low-fat, low-calorie and fibre claims peaked in the 1980s (all P < 0.01), whereas the odds of specific fat claims was greatest in the 1990s (P = 0.015). Representation of food resonated with prevailing food culture but was not always congruent with nutrition policy. © 2013 The Authors Journal of Human Nutrition and Dietetics © 2013 The British Dietetic Association Ltd.

  5. Capsule endoscopy—A mechatronics perspective

    Science.gov (United States)

    Lin, Lin; Rasouli, Mahdi; Kencana, Andy Prima; Tan, Su Lim; Wong, Kai Juan; Ho, Khek Yu; Phee, Soo Jay

    2011-03-01

    The recent advances in integrated circuit technology, wireless communication, and sensor technology have opened the door for development of miniature medical devices that can be used for enhanced monitoring and treatment of medical conditions. Wireless capsule endoscopy is one of such medical devices that has gained significant attention during the past few years. It is envisaged that future wireless capsule endoscopies replace traditional endoscopy procedures by providing advanced functionalities such as active locomotion, body fluid/tissue sampling, and drug delivery. Development of energy-efficient miniaturized actuation mechanisms is a key step toward achieving this goal. Here, we review some of the actuators that could be integrated into future wireless capsules and discuss the existing challenges.

  6. First clinical exploration of Buddleja officinalis and Xueshuangtong capsule on mild and moderate simple diabetic retinopathy

    Directory of Open Access Journals (Sweden)

    Hong Hu

    2013-11-01

    Full Text Available AIM: To observe the clinical effect of Buddleja officinalis and Xueshuangtong capsule treating the mild and moderate simple diabetic retinopathy(sDR. METHODS: Based on the strict control of blood glucose and blood pressure, eighty patients(160 eyeswith mild and moderate sDR were randomized into two groups equally: Buddleja officinalis(15g,tidand Xueshuangtong capsule administered to group A and only Xueshuangtong capsule administered to group B. They are taken before meals half an hour. The vision, funduscopy, FFA, fundus photography and traditional chinese medcine symptoms(TCMSwere evalutated before and after treatment in 7d,42 d respectively.RESULTS: There were no significant difference between two groups in terms of patients' gender, age, DM course, visual acuity, course of disease and TCM syndrome.(χ 2 sex=0.472, P>0.05; tage=1.742,tDM condition=0.716,tvision=0.662,tDR degree=1.276,tDR condition=0.562,t TCMS=0.616,P >0.05; Follow up for 42d on average after treatment the effective rate of fundus lesions of group A was 56%and the total effective rate was 82%,while the effective rate of group B was 32% and the total effective rate was 66%. The result showed that the curative effect of group A was better than that of group B. There were statistically significant difference for the effective rate between the two groups(χ2=8.025, Pχ 2=5.980,PCONCLUSION: Buddleja officinalis and Xueshuangtong capsule can improve the vision of patients with the mild and moderate sDR patients, the fundus lesions and the TCMS.

  7. Isolation of Capsulate Bacteria from Acute Dentoalveolar Abscesses

    OpenAIRE

    Lewis, M. A. O.; Milligan, S. G.; MacFarlane, T. W.; Carmichael, F. A.

    2011-01-01

    The presence of a capsule was determined for 198 bacterial strains (57 facultative anaerobes, 141 strict anaerobes) isobdted from pus samples aspirated from 40 acute dentoalveolar abscesses. A total of 133 (67 per cent) of the isolates (42 facultative anaerobes, 91 strict anaerobes) were found to have a capsule. Possession ofa capsule may in part explain the apparent pathogenicity of the bacterial species encountered in acute dentoalveolar abscess.Keywords - Bacterial capsule; Acute dentoalve...

  8. Pixel sensors with slim edges and small pitches for the CMS upgrades for HL-LHC

    Energy Technology Data Exchange (ETDEWEB)

    Vernieri, Caterina, E-mail: cvernier@fnal.gov [Fermilab, Batavia, IL 60510 (United States); Bolla, Gino; Rivera, Ryan; Uplegger, Lorenzo [Fermilab, Batavia, IL 60510 (United States); Zoi, Irene [Fermilab, Batavia, IL 60510 (United States); University of Florence, Firenze, 50121 (Italy)

    2017-02-11

    Planar n-in-n silicon detectors with small pitches and slim edges are being investigated for the innermost layers of tracking devices for the foreseen upgrades of the LHC experiments. Sensor prototypes compatible with the CMS readout, fabricated by Sintef, were tested in the laboratory and with a 120 GeV/c proton beam at the Fermilab test beam facility before and after irradiation with up to 2×10{sup 15} n{sub eq}/cm{sup 2} fluence. Preliminary results of the data analysis are presented.

  9. Slim 198gold-grain implanter loaded with standard royal marsden 14-grain magazines

    International Nuclear Information System (INIS)

    Delclos, L.; Moore, E.B.

    1979-01-01

    We designed a slim gold-grain implanter with adaptable lengths to implant areas accessible only through long, narrow, examining instruments, such as a suspension laryngoscope. The implanter is loaded with the same 14-grain magazine designed for and supplied with the Royal Marsden gun. The simplicity of the loading mechanism with a minimum of moving parts makes the instrument practically trouble free. Although it is designed to be used along narrow examining instruments, it can also be used in any situation in which a permanent implant is required, for instance, prostatic cancer and pelvic recurrences in cancer of the uterine cervix previously treated by external and intracavitary irradiation

  10. Capsule Endoscopy

    Science.gov (United States)

    ... because experience with it is limited and traditional upper endoscopy is widely available. Why it's done Your doctor might recommend a capsule endoscopy procedure to: Find the cause of gastrointestinal bleeding. If you have unexplained bleeding in your digestive ...

  11. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B G; Joo, K N [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  12. Capsule development and utilization for material irradiation tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules

  13. Exporting an Inherently Harmful Product: The Marketing of Virginia Slims Cigarettes in the United States, Japan, and Korea.

    Science.gov (United States)

    Dewhirst, Timothy; Lee, Wonkyong B; Fong, Geoffrey T; Ling, Pamela M

    2016-11-01

    Ethical issues surrounding the marketing and trade of controversial products such as tobacco require a better understanding. Virginia Slims, an exclusively women's cigarette brand first launched in 1968 in the USA, was introduced during the mid 1980s to major Asian markets, such as Japan and Korea, dominated by male smokers. By reviewing internal corporate documents, made public from litigation, we examine the marketing strategies used by Philip Morris as they entered new markets such as Japan and Korea and consider the extent that the company attempted to appeal to women in markets where comparatively few women were smokers. The case study of Virginia Slims reveals that the classification of "vulnerable" consumers is variable depending on culture, tobacco firms display responsive efforts and strategies when operating within a "mature" market, and cultural values played a role in informing Philip Morris' strategic decision to embrace an adaptive marketing approach, particularly when entering the Korean market. Finally, moral questions are raised with tobacco being identified as a priority product for export and international trade agreements being used by corporations, governments, or trade partners in efforts to undermine domestic public health policies.

  14. Exporting an Inherently Harmful Product: The Marketing of Virginia Slims Cigarettes in the United States, Japan, and Korea

    Science.gov (United States)

    Lee, Wonkyong B.; Fong, Geoffrey T.; Ling, Pamela M.

    2015-01-01

    Ethical issues surrounding the marketing and trade of controversial products such as tobacco require a better understanding. Virginia Slims, an exclusively women’s cigarette brand first launched in 1968 in the USA, was introduced during the mid 1980s to major Asian markets, such as Japan and Korea, dominated by male smokers. By reviewing internal corporate documents, made public from litigation, we examine the marketing strategies used by Philip Morris as they entered new markets such as Japan and Korea and consider the extent that the company attempted to appeal to women in markets where comparatively few women were smokers. The case study of Virginia Slims reveals that the classification of “vulnerable” consumers is variable depending on culture, tobacco firms display responsive efforts and strategies when operating within a “mature” market, and cultural values played a role in informing Philip Morris’ strategic decision to embrace an adaptive marketing approach, particularly when entering the Korean market. Finally, moral questions are raised with tobacco being identified as a priority product for export and international trade agreements being used by corporations, governments, or trade partners in efforts to undermine domestic public health policies. PMID:28025588

  15. Adsorption and desorption of phosphorus in ceramic capsules

    International Nuclear Information System (INIS)

    Almeida, J.R.F. de.

    1983-01-01

    Experiments were carried out in order to analyse the capacity of adsorving P from water using ceramic capsules with 32P, in the presence and absence of water flow through the capsule. Also studied was the desorption of 32 P from the capsule in water, with and without water flow. The desorption of residual 32 P was analysed by isotopic exchange with 31 P, also with and without water flow. It was observed that, in the presence of a flow, the capsule retained 32 P from the solution, which was weakly desorbed by water but was isotopically exchanged with 31 P. In the absence of a flow, the capsule was not an efficient P adsorber. (Author) [pt

  16. Production, deformation and mechanical investigation of magnetic alginate capsules

    Science.gov (United States)

    Zwar, Elena; Kemna, Andre; Richter, Lena; Degen, Patrick; Rehage, Heinz

    2018-02-01

    In this article we investigated the deformation of alginate capsules in magnetic fields. The sensitivity to magnetic forces was realised by encapsulating an oil in water emulsion, where the oil droplets contained dispersed magnetic nanoparticles. We solved calcium ions in the aqueous emulsion phase, which act as crosslinking compounds for forming thin layers of alginate membranes. This encapsulating technique allows the production of flexible capsules with an emulsion as the capsule core. It is important to mention that the magnetic nanoparticles were stable and dispersed throughout the complete process, which is an important difference to most magnetic alginate-based materials. In a series of experiments, we used spinning drop techniques, capsule squeezing experiments and interfacial shear rheology in order to determine the surface Young moduli, the surface Poisson ratios and the surface shear moduli of the magnetically sensitive alginate capsules. In additional experiments, we analysed the capsule deformation in magnetic fields. In spinning drop and capsule squeezing experiments, water droplets were pressed out of the capsules at elevated values of the mechanical load. This phenomenon might be used for the mechanically triggered release of water-soluble ingredients. After drying the emulsion-filled capsules, we produced capsules, which only contained a homogeneous oil phase with stable suspended magnetic nanoparticles (organic ferrofluid). In the dried state, the thin alginate membranes of these particles were rather rigid. These dehydrated capsules could be stored at ambient conditions for several months without changing their properties. After exposure to water, the alginate membranes rehydrated and became flexible and deformable again. During this swelling process, water diffused back in the capsule. This long-term stability and rehydration offers a great spectrum of different applications as sensors, soft actuators, artificial muscles or drug delivery systems.

  17. Capsule endoscopy: Beyond small bowel

    Directory of Open Access Journals (Sweden)

    Samuel N Adler

    2012-01-01

    Full Text Available In this article the brief and dramatic history of capsule endoscopy of the digestive tract is reviewed. Capsule endoscopy offers a non invasive method to diagnose diseases that affect the esophagus, small bowel and colon. Technological improvements relating to optics, software, data recorders with two way communication have revolutionized this field. These advancements have produced better diagnostic performance.

  18. Capsule development and utilization for material irradiation tests

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N. [and others

    2000-05-01

    The development program of advanced nuclear structural and fuel materials includes the in-pile tests using the instrumented capsule at HANARO. The tests were performed in the in-core test holes of CT, IR 1 and 2 and OR 4 and 5 of HANARO. Extensive efforts have also been made to establish design and manufacturing technology for the instrumented capsule and its related system, which should be compatible with the HANARO's characteristics. Since the first instrumented capsule(97M-01K) had been designed and successfully fabricated, five tests were done to support the users and provided the economic benefits to user by generating the essential in-pile information on the performance and structural integrity of materials. This paper describes the present status and future plans of these R and D activities for the development of the instrumented capsule including in-situ material property measurement capsules and nuclear fuel test capsules.

  19. Motion of an elastic capsule in a square microfluidic channel.

    Science.gov (United States)

    Kuriakose, S; Dimitrakopoulos, P

    2011-07-01

    In the present study we investigate computationally the steady-state motion of an elastic capsule along the centerline of a square microfluidic channel and compare it with that in a cylindrical tube. In particular, we consider a slightly over-inflated elastic capsule made of a strain-hardening membrane with comparable shearing and area-dilatation resistance. Under the conditions studied in this paper (i.e., small, moderate, and large capsules at low and moderate flow rates), the capsule motion in a square channel is similar to and thus governed by the same scaling laws with the capsule motion in a cylindrical tube, even though in the channel the cross section in the upstream portion of large capsules is nonaxisymmetric (i.e., square-like with rounded corners). When the hydrodynamic forces on the membrane increase, the capsule develops a pointed downstream edge and a flattened rear (possibly with a negative curvature) so that the restoring tension forces are increased as also happens with droplets. Membrane tensions increase significantly with the capsule size while the area near the downstream tip is the most probable to rupture when a capsule flows in a microchannel. Because the membrane tensions increase with the interfacial deformation, a suitable Landau-Levich-Derjaguin-Bretherton analysis reveals that the lubrication film thickness h for large capsules depends on both the capillary number Ca and the capsule size a; our computations determine the latter dependence to be (in dimensionless form) h ~ a(-2) for the large capsules studied in this work. For small and moderate capsule sizes a, the capsule velocity Ux and additional pressure drop ΔP+ are governed by the same scaling laws as for high-viscosity droplets. The velocity and additional pressure drop of large thick capsules also follow the dynamics of high-viscosity droplets, and are affected by the lubrication film thickness. The motion of our large thick capsules is characterized by a Ux-U ~ h ~ a(-2

  20. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    Science.gov (United States)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-03-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  1. Development of remote welding techniques for in-pile IASCC capsules and evaluation of material integrity on capsules for long irradiation period

    International Nuclear Information System (INIS)

    Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.

    2012-01-01

    To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0–3.9 × 10 26 n/m 2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03–1.0 × 10 26 n/m 2 . Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.

  2. Polar tent for reduced perturbation of NIF ignition capsules

    Science.gov (United States)

    Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.

    2016-10-01

    In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.

  3. Diagnostic and therapeutic capsules and method of producing

    International Nuclear Information System (INIS)

    Morcos, N.A.; Haney, T.A.; Wedeking, P.W.

    1981-01-01

    An article of manufacture comprising a pharmaceutical radioactive capsule formed essentially of a non-toxic, water soluble material adapted to being ingested and rapidly disintegrating on contract with fluids of the gastro-intestinal tract, and having a filler material supporting a pharmaceutically useful radioactive compound absorbable from the gastro-intestinal tract said filler material being supported by said capsule. And a method of filling a pharmaceutical radioactive capsule comprising providing filler material supporting a pharmaceutically useful radioactive compound and transporting said filler material carrying a pharmaceutically useful radioactive compound into the chamber of said capsule

  4. Evidence for an intact polysaccharide capsule in Bordetella pertussis.

    Science.gov (United States)

    Neo, YiLin; Li, Rui; Howe, Josephine; Hoo, Regina; Pant, Aakanksha; Ho, SiYing; Alonso, Sylvie

    2010-03-01

    Polysaccharide capsules contribute to the pathogenesis of many bacteria species by providing resistance against various defense mechanisms. The production of a capsule in Bordetella pertussis, the etiologic agent of whooping cough, has remained controversial; earlier studies reported this pathogen as a capsulated microorganism whereas the recent B. pertussis genome analysis revealed the presence of a truncated capsule locus. In this work, using transmission electron microscopy and immunostaining approaches, we provide a formal evidence for the presence of an intact microcapsule produced at the surface of both laboratory strain and clinical isolates of B. pertussis. In agreement with previous studies, we found that the capsule is optimally produced in avirulent phase. Unexpectedly, the presence of the capsule was also detected at the surface of virulent B. pertussis bacteria. Consistently, a substantial transcriptional activity of the capsule operon was detected in virulent phase, suggesting that the capsular polysaccharide may play a role during pertussis pathogenesis. In vitro assays indicated that the presence of the capsule does not affect B. pertussis adherence to mammalian cells and does not further protect the bacterium from phagocytosis, complement-mediated killing or antimicrobial peptide attack. Copyright 2009. Published by Elsevier SAS.

  5. Identification of adulterants in a Chinese herbal medicine by LC-HRMS and LC-MS-SPE/NMR and comparative in vivo study with standards in a hypertensive rat model

    DEFF Research Database (Denmark)

    Kesting, Julie Regitze; Huang, JingQi; Sørensen, Dan

    2010-01-01

    Based on anecdotal evidence of anti-hypertensive effect of Gold Nine Soft Capsules, an in vivo study of this complex Chinese "herbal-based" medicine was initiated. Dosage of the content of Gold Nine capsules in spontaneous hypertensive rats showed a remarkably good effect. This led to further...... of a combination of commercially purchased standards was shown to be equivalent to that of the capsule content. Adulteration of herbal remedies and dietary supplements with synthetic drugs is an increasing problem that may lead to serious adverse effects. LC-MS-SPE/NMR as a method for the rapid identification...

  6. Endurance test for DUPIC capsule

    International Nuclear Information System (INIS)

    Chung, Heung June; Bae, K. K.; Lee, C. Y.; Park, J. M.; Ryu, J. S.

    1999-07-01

    This report presents the pressure drop, vibration and endurance test results for mini-plate fuel rig which were designed fabricately by KAERI. From the pressure drop test results, it is noted that the flow rate across the capsule corresponding to the pressure drop of 200 kPa is measured to be about 9.632 kg/sec. Vibration frequency for the capsule ranges from 14 to 18.5 Hz. RMS (Root Mean Square) displacement for the fuel rig is less than 14 μm, and the maximum displacement is less than 54 μm. Based on the endurance test results, the appreciable fretting wear for the DUPIC capsule was not detected. Oxidation on the support tube is observed, also tiny trace of wear between contact points observed. (author). 4 refs., 10 tabs., 45 figs

  7. A simple method for preparing radioactive capsules in colon transit study

    International Nuclear Information System (INIS)

    Wang Shyhjen; Lin Wanyu; Tsai Shihchuan; Chen Granhun

    2000-01-01

    Colon transit study is currently performed by delivering technetium-99m or indium-111 labelled activated charcoal to the colon in a methacrylate-coated capsule (coated capsule). However, the coating procedure is complicated and methacrylate has not been approved by the Food and Drug Administration. Therefore, a simpler method is needed for the clinical routine use of colon transit study. In this study, we used a commercial empty enteric capsule and a coated capsule for the measurement of colon transit time. We compared the in vitro stability and in vivo scintigraphy of 99m Tc-labelled activated charcoal in the coated capsule and the enteric capsule to evaluate the possibility of clinical usage of the enteric capsule for colon transit time study. Activated charcoal powder was mixed with 99m Tc-diethylene triamine penta-acetic acid (DTPA) and vaporized to dryness. The dry 99m Tc-DTPA activated charcoal was loaded into the coated capsule and the enteric capsule. In vitro stability study was performed by immersing these capsules in a colourless buffer of variable pH which mimicked the conditions in the stomach and the small bowel. Capsule disruption was determined. Colon transit scintigraphy with 99m Tc-DTPA charcoal was performed in five normal volunteers using these two capsules. The in vitro stability of these two types of capsule was similar and the colon transit scintigraphy findings were almost identical. Most capsules dissolved in the ascending colon and very few in the terminal ileum. It is concluded that enteric capsule is a suitable alternative to coated capsule for measurement of colon transit. (orig.)

  8. Traditional Chinese medicine formula Bi-Qi capsule alleviates rheumatoid arthritis-induced inflammation, synovial hyperplasia, and cartilage destruction in rats.

    Science.gov (United States)

    Wang, Kai; Zhang, Dongmei; Liu, Yan; Wang, Xuan; Zhao, Jiantong; Sun, Tingting; Jin, Tingting; Li, Baoli; Pathak, Janak L

    2018-03-14

    Traditional Chinese medicine (TCM) formula Bi-Qi capsule (Bi-Qi) is a commonly prescribed drug to treat rheumatoid arthritis (RA). However, the mechanism of Bi-Qi-mediated amelioration of RA pathogenesis is still a mystery. Collagen induced arthritis (CIA) in rats is an established model that shares many similarities with RA in humans. In this study we investigated the effect of Bi-Qi on the pathogenesis of CIA in rats. CIA was developed in Sprague-Dawley (S.D) rats (n = 60, female) and used as a model resembling RA in humans. Rats were treated with a high or moderate dose of Bi-Qi, or methotrexate (MTX). Effects of the treatment on local joint and systemic inflammation, synovial hyperplasia, cartilage destruction, and other main features in the pathogenesis of CIA were analyzed. Inflamed and swollen ankles and joints were observed in arthritic rats, while Bi-Qi or MTX treatment alleviated these symptoms. Only the Bi-Qi moderate dose decreased RA-induced serum levels of tumor necrosis factor-alpha (TNF-α). Both Bi-Qi and MTX reduced the interleukin (IL)-18 serum level. Protein levels of cartilage oligomeric matrix protein and osteopontin in serum, synovium, and cartilage were elevated in arthritic rats, while Bi-Qi alleviated these effects. Synovial hyperplasia, inflammatory cell infiltration in synovium and a high degree of cartilage degradation was observed in RA, and Bi-Qi or MTX alleviated this effect. Bi-Qi at the moderate dose was the most effective in mitigating CIA-related clinical complications. Our findings showed that Bi-Qi alleviates CIA-induced inflammation, synovial hyperplasia, cartilage destruction, and the other main features in the pathogenesis of CIA. This provides fundamental evidence for the anti-arthritic properties of Bi-Qi and corroborates the use of Bi-Qi TCM formula for the treatment of RA.

  9. Failure of the capsule for coated particles irradiation

    International Nuclear Information System (INIS)

    Yamaki, Jikei; Nomura, Yasushi; Nagamatsuya, Takaaki; Yamahara, Takeshi; Sakai, Haruyuki

    1975-10-01

    During operation cycle No. 27 of the JMTR (Japan Material Testing Reactor) on May 20, 1974, leakage of the fission product gas occurred from the capsule 72F-7A, which contained coated particles for the irradiation; the coated particles are for the development of a multi-purpose high temperature gas cooled reactor. The capsule was designed for heat 1600 0 C. Three nickel plates as the heat reflector were sandwiched in between the plates of titanium and zirconium, which were adsorbents for the impurity gases in the cladding tube (Nb-1%Zr). Temperatures of the plates were about 1000 0 C under the irradiation, so one metal diffused into the other metal through interfaces, resulting in the formation of an alloy. Its melting point was lower than those of metals in the capsule. The cladding material Nb-1%Zr was melted by the alloy and finally a pin hole developed through the cladding. The process of failure, design of the capsule, post-irradiation test of the capsule and the failure-reproducing experiment with a mock-up capsule are described. (auth.)

  10. Liquid-core nanocellulose-shell capsules with tunable oxygen permeability.

    Science.gov (United States)

    Svagan, A J; Bender Koch, C; Hedenqvist, M S; Nilsson, F; Glasser, G; Baluschev, S; Andersen, M L

    2016-01-20

    Encapsulation of oxygen sensitive components is important in several areas, including those in the food and pharmaceutical sectors, in order to improve shelf-life (oxidation resistance). Neat nanocellulose films demonstrate outstanding oxygen barrier properties, and thus nanocellulose-based capsules are interesting from the perspective of enhanced protection from oxygen. Herein, two types of nanocellulose-based capsules with liquid hexadecane cores were successfully prepared; a primary nanocellulose polyurea-urethane capsule (diameter: 1.66 μm) and a bigger aggregate capsule (diameter: 8.3 μm) containing several primary capsules in a nanocellulose matrix. To quantify oxygen permeation through the capsule walls, an oxygen-sensitive spin probe was dissolved within the liquid hexadecane core, allowing non-invasive measurements (spin-probe oximetry, electron spin resonance, ESR) of the oxygen concentration within the core. It was observed that the oxygen uptake rate was significantly reduced for both capsule types compared to a neat hexadecane solution containing the spin-probe, i.e. the slope of the non-steady state part of the ESR-curve was approximately one-third and one-ninth for the primary nanocellulose capsule and aggregated capsule, respectively, compared to that for the hexadecane sample. The transport of oxygen was modeled mathematically and by fitting to the experimental data, the oxygen diffusion coefficients of the capsule wall was determined. These values were, however, lower than expected and one plausible reason for this was that the ESR-technique underestimate the true oxygen uptake rate in the present systems at non-steady conditions, when the overall diffusion of oxygen was very slow. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Deformation of ovalbumin-alginate capsules in a T-Junction

    Science.gov (United States)

    Häner, Edgar; Juel, Anne

    2015-11-01

    We study experimentally the flow-induced deformation of liquid-filled ovalbumin-alginate capsules in a T-junction. In applications, capsules/cells often negotiate branched networks with junctions thus experiencing large deformations. We investigate the constant volume-flux viscous flow of buoyancy-neutral thin-walled capsules close to the centreline of rectangular channels, by comparison to near-rigid gelled beads. The motion of the capsules in straight channels scales with the capillary number - the ration of viscous to elastic forces. However, the effect of elastic deformation on the motion is sufficiently weak that a rigid sphere model predicts the velocity of capsules with diameters of up to 70% of that of the channel to within 5%. In the T-junction, systematic selection of daughter channel (right-left) occurs outside a finite region around the channel centreline, by contrast with near-rigid gelled beads, where the actual centreline is the separator. We quantify the behaviour of capsules in terms of their longitudinal stretching (up to a factor of three without rupture). We show the large range of deformations encountered can be applied to the measurement of the elastic properties of capsules as well as to the geometric-induced sorting and manipulation of capsules.

  12. Development of a Low Temperature Irradiation Capsule for Research Reactor Materials

    International Nuclear Information System (INIS)

    Choo, Kee Nam; Cho, Man Soon; Lee, Cheol Yong; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Kang, Suk Hoon; Kang, Young Hwan; Park, Sang Jun

    2013-01-01

    A new capsule design was prepared and tested at HANARO for a neutron irradiation of core materials of research reactors as a part of the research reactor development project. Irradiation testing of the materials including graphite, beryllium, and zircaloy-4 that are supposed to be used as core materials in research reactors was required for irradiation at up to 8 reactor operation cycles at low temperature (<100 .deg. C). Therefore, three instrumented capsules were designed and fabricated for an evaluation of the neutron irradiation properties of the core materials (Graphite, Be, Zircaloy-4) of research reactors. The capsules were first designed and fabricated to irradiate materials at low temperature (<100 .deg. C) for a long cycle of 8 irradiation cycles at HANARO. Therefore, the safety of the new designed capsule should be fully checked before irradiation testing. Out-pile performance and endurance testing before HANARO irradiation testing was performed using a capsule under a 110% condition of a reactor coolant flow amount. The structural integrity of the capsule was analyzed in terms of a vibration-induced fatigue cracking of a rod tip of the capsule that is suspected to be the most vulnerable part of a capsule. Another two capsules were irradiated at HANARO for 4 cycles, and one capsule was transferred to a hot cell to examine the integrity of the rod tip of the capsule. After confirming the soundness of the 4 cycle-irradiated capsule, the remaining capsule was irradiated at up to 8 cycles at HANARO. Based on the structural integrity analysis of the capsule, an improved capsule design will be suggested for a longer irradiation test at HANARO

  13. Three-dimensional simulations of Nova capsule implosion experiments

    International Nuclear Information System (INIS)

    Marinak, M.M.; Tipton, R.E.; Landen, O.L.

    1995-01-01

    Capsule implosion experiments carried out on the Nova laser are simulated with the three-dimensional HYDRA radiation hydrodynamics code. Simulations of ordered near single mode perturbations indicate that structures which evolve into round spikes can penetrate farthest into the hot spot. Bubble-shaped perturbations can burn through the capsule shell fastest, however, causing even more damage. Simulations of a capsule with multimode perturbations shows spike amplitudes evolving in good agreement with a saturation model during the deceleration phase. The presence of sizable low mode asymmetry, caused either by drive asymmetry or perturbations in the capsule shell, can dramatically affect the manner in which spikes approach the center of the hot spot. Three-dimensional coupling between the low mode shell perturbations intrinsic to Nova capsules and the drive asymmetry brings the simulated yields into closer agreement with the experimental values

  14. Equilibrium ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lackner, K.S.; Colgate, S.A.; Johnson, N.L.; Kirkpatrick, R.C.; Menikoff, R.; Petschek, A.G.

    1993-01-01

    There are two fundamentally different approaches to igniting DT fuel in an ICF capsule which can be described as equilibrium and hot spot ignition. In both cases, a capsule which can be thought of as a pusher containing the DT fuel is imploded until the fuel reaches ignition conditions. In comparing high-gain ICF targets using cryogenic DT for a pusher with equilibrium ignition targets using high-Z pushers which contain the radiation. The authors point to the intrinsic advantages of the latter. Equilibrium or volume ignition sacrifices high gain for lower losses, lower ignition temperature, lower implosion velocity and lower sensitivity of the more robust capsule to small fluctuations and asymmetries in the drive system. The reduction in gain is about a factor of 2.5, which is small enough to make the more robust equilibrium ignition an attractive alternative

  15. Positron radiography of ignition-relevant ICF capsules

    Science.gov (United States)

    Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.

    2017-12-01

    Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.

  16. Capsule-odometer: a concept to improve accurate lesion localisation.

    Science.gov (United States)

    Karargyris, Alexandros; Koulaouzidis, Anastasios

    2013-09-21

    In order to improve lesion localisation in small-bowel capsule endoscopy, a modified capsule design has been proposed incorporating localisation and - in theory - stabilization capabilities. The proposed design consists of a capsule fitted with protruding wheels attached to a spring-mechanism. This would act as a miniature odometer, leading to more accurate lesion localization information in relation to the onset of the investigation (spring expansion e.g., pyloric opening). Furthermore, this capsule could allow stabilization of the recorded video as any erratic, non-forward movement through the gut is minimised. Three-dimensional (3-D) printing technology was used to build a capsule prototype. Thereafter, miniature wheels were also 3-D printed and mounted on a spring which was attached to conventional capsule endoscopes for the purpose of this proof-of-concept experiment. In vitro and ex vivo experiments with porcine small-bowel are presented herein. Further experiments have been scheduled.

  17. Production of 131I gelatin capsules

    International Nuclear Information System (INIS)

    Freud, A.; Hirshfeld, N.; Canfi, A.; Melamud, Y.

    1997-01-01

    Radioiodine ( 131 I) hard-gelatin capsules are widely used for the diagnosis and treatment of various thyroid disorders. Until 1980 radioiodine was supplied by us as a liquid dosage. This proved to be a rather inconvenient form since it resulted in inaccurate dosing by the physicians and caused frequent contamination of the patients and the hospital personnel. In an attempt to overcome these problems we have designed and constructed a production facility for capsules in which 1311 is packaged. Because of the extreme precautions necessary in handling radioactive compounds, encapsulation of radioactive materials requires specifically designed production techniques, special instrumentation and unique quality control procedures that are not encountered in the standard capsule production processes in the pharmaceutical industry

  18. Pneumatic capsule with a measuring system for in-pile irradiation

    International Nuclear Information System (INIS)

    Oshima, Keiichi; Yamazaki, Yasaburo; Hirata, Mitsuho; Ishii, Toshio; Shimozawa, Ryohei.

    1967-01-01

    A prior-art in-pile irradiation apparatus wherein a rabbit containing an irradiation specimen therein is inserted into and removed from a pile by a pneumatic system does not include means for measuring the temperature and pressure of the specimen under irradiation. When the rabbit is deformed during irradiation, it cannot be reliably recovered. A pneumatic capsule assembly with a measuring system according to this invention has a double structure which consists of an inner capsule containing the specimen therein and an outer capsule evacuated or filled with a gas. A thermocouple lace wire and a strain gauge are welded on the outside surface of the inner capsule as detection terminals for measuring the temperature and pressure. A rupture plate which bursts when the pressure in the inner capsule reaches a predetermined value is provided at a part of the inner capsule, and a fin for heat transmission is provided between the inner and outer capsules to thus prevent the deformation of the pneumatic capsule assembly as a whole. (Takasuka, S.)

  19. No stabilizing effect of the elbow joint capsule. A kinematic study

    DEFF Research Database (Denmark)

    Nielsen, K K; Olsen, Bo Sanderhoff

    1999-01-01

    We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule.......We dissected 7 cadaveric elbow specimens, leaving the collateral ligaments and the joint capsule intact. The anterior and the posterior capsule were sequentially transected, followed by kinematic testings. We found no change in joint laxity after total transection of the capsule....

  20. Radioactive gas-containing polymeric capsule

    International Nuclear Information System (INIS)

    Winchell, H.S.; Lewis, R.E.

    1975-01-01

    A disposable ventilation study system for dispensing a single patient dosage of gaseous radioisotopes to patients for pulmonary function studies is disclosed. A gas impermeable capsule encloses the gaseous radioisotope and is stored within a radioactivity shielding body of valve means which shears the capsule to dispense the radioisotope to the patient. A breathing bag receives the patient's exhalation of the radioisotope and permits rebreathing of the radioisotope by the patient. 18 claims, 7 drawing figures

  1. Design procedure of capsule with multistage heater control (named MUSTAC)

    International Nuclear Information System (INIS)

    Someya, Hiroyuki; Endoh, Yasuichi; Hoshiya, Taiji; Niimi, Motoji; Harayama, Yasuo

    1990-11-01

    A capsule with electric heaters at multistage (named MUSTAC) is a type of capsule used in JMTR. The heaters are assembled in the capsule. Supply electric current to the heaters can be independently adjusted with a control systems that keeps irradiation specimens to constant temperature. The capsule being used, the irradiation specimen are inserted into specimen holders. Gas-gap size, between outer surface of specimen holders and inner surface of capsule casing, is calculated and determined to be flatten temperature of loaded specimens over the region. The rise or drop of specimen temperature in accordance with reactor power fluctuations is corrected within the target temperature of specimen by using the heaters filled into groove at specimen holder surface. The present report attempts to propose a reasonable design procedure of the capsules by means of compiling experience for designs, works and irradiation data of the capsules and to prepare for useful informations against onward capsule design. The key point of the capsule lies on thermal design. Now design thermal calculations are complicated in case of specimen holder with multihole. Resolving these issues, it is considered from new on that an emphasis have to placed on settling a thermal calculation device, for an example, a computer program on calculation specimen temperature. (author)

  2. Ingestible capsule for remote controlled release of a substance

    DEFF Research Database (Denmark)

    2014-01-01

    The application relates to an ingestible capsule (102) for delivery of a substance e.g. a pharmaceutical drug, to a human or animal. The ingestible capsule comprises a capsule wall structure (202) forming a substantially sealed reservoir or lumen holding the substance (204). An electrical resonance...

  3. Compression Ratio Ion Mobility Programming (CRIMP) Accumulation and Compression of Billions of Ions for Ion Mobility-Mass Spectrometry Using Traveling Waves in Structures for Lossless Ion Manipulations (SLIM)

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Liulin; Garimella, Venkata BS; Hamid, Ahmed M.; Webb, Ian K.; Attah, Isaac K.; Norheim, Randolph V.; Prost, Spencer A.; Zheng, Xueyun; Sandoval, Jeremy A.; Baker, Erin M.; Ibrahim, Yehia M.; Smith, Richard D.

    2017-05-25

    We report on the implementation of a traveling wave (TW) based compression ratio ion mobility programming (CRIMP) approach within Structures for Lossless Ion Manipulations (SLIM) that enables both greatly enlarged trapped ion charge capacities and also their subsequent efficient compression for use in ion mobility (IM) separations. Ion accumulation is conducted in a long serpentine path TW SLIM region after which CRIMP allows the large ion populations to be ‘squeezed’. The compression process occurs at an interface between two SLIM regions, one operating conventionally and the second having an intermittently pausing or ‘stuttering’ TW, allowing the contents of multiple bins of ions from the first region to be merged into a single bin in the second region. In this initial work stationary voltages in the second region were used to block ions from exiting the first (trapping) region, and the resumption of TWs in the second region allows ions to exit, and the population to also be compressed if CRIMP is applied. In our initial evaluation we show that the number of charges trapped for a 40 s accumulation period was ~5×109, more than two orders of magnitude greater than the previously reported charge capacity using an ion funnel trap. We also show that over 1×109 ions can be accumulated with high efficiency in the present device, and that the extent of subsequent compression is only limited by the space charge capacity of the trapping region. Lower compression ratios allow increased IM peak heights without significant loss of signal, while excessively large compression ratios can lead to ion losses and other artifacts. Importantly, we show that extended ion accumulation in conjunction with CRIMP and multiple passes provides the basis for a highly desirable combination of ultra-high sensitivity and ultra-high resolution IM separations using SLIM.

  4. Spheroidal and conical shapes of ferrofluid-filled capsules in magnetic fields

    Science.gov (United States)

    Wischnewski, Christian; Kierfeld, Jan

    2018-04-01

    We investigate the deformation of soft spherical elastic capsules filled with a ferrofluid in external uniform magnetic fields at fixed volume by a combination of numerical and analytical approaches. We develop a numerical iterative solution strategy based on nonlinear elastic shape equations to calculate the stretched capsule shape numerically and a coupled finite element and boundary element method to solve the corresponding magnetostatic problem and employ analytical linear response theory, approximative energy minimization, and slender-body theory. The observed deformation behavior is qualitatively similar to the deformation of ferrofluid droplets in uniform magnetic fields. Homogeneous magnetic fields elongate the capsule and a discontinuous shape transition from a spheroidal shape to a conical shape takes place at a critical field strength. We investigate how capsule elasticity modifies this hysteretic shape transition. We show that conical capsule shapes are possible but involve diverging stretch factors at the tips, which gives rise to rupture for real capsule materials. In a slender-body approximation we find that the critical susceptibility above which conical shapes occur for ferrofluid capsules is the same as for droplets. At small fields capsules remain spheroidal and we characterize the deformation of spheroidal capsules both analytically and numerically. Finally, we determine whether wrinkling of a spheroidal capsule occurs during elongation in a magnetic field and how it modifies the stretching behavior. We find the nontrivial dependence between the extent of the wrinkled region and capsule elongation. Our results can be helpful in quantitatively determining capsule or ferrofluid material properties from magnetic deformation experiments. All results also apply to elastic capsules filled with a dielectric liquid in an external uniform electric field.

  5. Conceptual design of the SlimCS fusion DEMO reactor

    International Nuclear Information System (INIS)

    Tobita, Kenji; Nishio, Satoshi; Enoeda, Mikio; Nakamura, Hirofumi; Hayashi, Takumi; Asakura, Nobuyuki; Utoh, Hiroyasu; Tanigawa, Hiroyasu; Nishitani, Takeo; Isono, Takaaki; Sakurai, Shinji; Kurita, Genichi; Hayashi, Takao; Oyama, Naoyuki; Liu Changle; Hamamatsu, Kiyotaka; Inoue, Takashi; Ozeki, Takahisa; Sato, Masayasu; Suzuki, Satoshi; Kawashima, Hisato; Ezato, Koichiro; Tsuru, Daigo; Koizumi, Norikiyo; Sakamoto, Keiji; Ando, Masami; Sakamoto, Yoshiteru; Shibama, Yusuke; Suzuki, Takahiro; Takechi, Manabu; Takahashi, Koji; Hirose, Takanori; Sato, Satoru; Nozawa, Takashi; Tanigawa, Hisashi; Kakudate, Satoshi; Kawamura, Yoshinori; Yamanishi, Toshihiko; Hoshino, Tsuyoshi; Ochiai, Kentaro; Ide, Shunsuke; Aiba, Nobuyuki; Shimizu, Katsuhiro; Honda, Mitsuru; Nakamichi, Masaru; Nishi, Hiroshi; Seki, Yoji; Nakamura, Yukiharu; Tsuchiya, Kunihiko; Yoshida, Tohru; Song Yuntao

    2010-08-01

    This report describes the results of the conceptual design study of the SlimCS fusion DEMO reactor aiming at demonstrating fusion power production in a plant scale and allowing to assess the economic prospects of a fusion power plant. The design study has focused on a compact and low aspect ratio tokamak reactor concept with a reduced-sized central solenoid, which is novel compared with previous tokamak reactor concept such as SSTR (Steady State Tokamak Reactor). Owing to low aspect ratio, the reactor will be capable of having comparatively high beta limit and high elongation (which can elevate the Greenwald density limit), having potential for high power density. The reactor has the main parameters of a major radius of 5.5 m, aspect ratio of 2.6, elongation of 2.0, normalized beta of 4.3, fusion out put of 2.95 GW and average neutron wall load of 3 MW/m 2 . This report covers various aspects of design study including systematic design, physics design, torus configuration, blanket, superconducting magnet, maintenance and building, which were carried out increase the engineering feasibility of the concept. (author)

  6. Scaling effects in spiral capsule robots.

    Science.gov (United States)

    Liang, Liang; Hu, Rong; Chen, Bai; Tang, Yong; Xu, Yan

    2017-04-01

    Spiral capsule robots can be applied to human gastrointestinal tracts and blood vessels. Because of significant variations in the sizes of the inner diameters of the intestines as well as blood vessels, this research has been unable to meet the requirements for medical applications. By applying the fluid dynamic equations, using the computational fluid dynamics method, to a robot axial length ranging from 10 -5 to 10 -2  m, the operational performance indicators (axial driving force, load torque, and maximum fluid pressure on the pipe wall) of the spiral capsule robot and the fluid turbulent intensity around the robot spiral surfaces was numerically calculated in a straight rigid pipe filled with fluid. The reasonableness and validity of the calculation method adopted in this study were verified by the consistency of the calculated values by the computational fluid dynamics method and the experimental values from a relevant literature. The results show that the greater the fluid turbulent intensity, the greater the impact of the fluid turbulence on the driving performance of the spiral capsule robot and the higher the energy consumption of the robot. For the same level of size of the robot, the axial driving force, the load torque, and the maximum fluid pressure on the pipe wall of the outer spiral robot were larger than those of the inner spiral robot. For different requirements of the operating environment, we can choose a certain kind of spiral capsule robot. This study provides a theoretical foundation for spiral capsule robots.

  7. Dynamics of an elastic capsule in moderate Reynolds number Poiseuille flow

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Sung, Hyung Jin

    2012-01-01

    Highlights: ► Dynamics of a capsule in moderate Re Poiseuille flow were explored numerically. ► Capsule tends to tumbling motion for larger membrane elasticity and higher Re flow. ► Capsule undergoes swinging motion for larger size and aspect ratio of the capsule. ► Capsule tends to migrate to a specific lateral equilibrium as Re increases. ► Equilibrium position varies differently around the transition of the dynamic motion. - Abstract: The dynamic motions and lateral equilibrium positions of a two-dimensional elastic capsule in a Poiseuille flow were explored at moderate Reynolds number (10 ⩽ Re ⩽ 100) as a function of the initial lateral position (y 0 ), Re, aspect ratio (ε), size ratio (λ), membrane stretching coefficient (φ) and bending coefficient (γ). The transition between tank-treading (TT) and swinging (SW) to tumbling (TU) motions was observed and the lateral equilibrium positions of the capsules varied according to the conditions. The initial behavior of the elastic capsule was influenced by variation in the initial lateral position (y 0 ), but the equilibrium position and dynamic motion of the capsule were not affected by such variation. The capsules had a stronger tendency toward TU motion at higher values of Re, φ and γ, whereas the capsules underwent TT or SW motion as the values of ε and λ increased. Under moderate Re Poiseuille flows, capsules tended to migrate across streamlines to a specific equilibrium position. The lateral equilibrium position shifted toward the centerline at larger λ and migrated toward the wall at larger ε,φandγ. As Re increased, the equilibrium position first shifted toward the bottom wall, then toward the channel center. However, different equilibrium position trends were obtained around the SW–TU transition. The capsule undergoing TU motion tended to migrate downward toward the bottom wall more than the capsule undergoing SW motion, all other conditions being similar.

  8. Blood-nourishing and Hard-softening Capsule Costs Less in the Management of Osteoarthritic Knee Pain: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Yuelong Cao

    2005-01-01

    Full Text Available The blood-nourishing and hard-softening (BNHS capsule is a traditional Chinese formula used in the symptomatic treatment of inflammation and pain. We conducted this randomized controlled trial to compare the efficacy of BNHS with other commonly prescribed drugs. We recruited 120 patients from two teaching hospitals; 30 patients in each hospital were randomly assigned to receive BNH In one hospital, the 30 controls were given another traditional Chinese drug; whereas a Western medicine (chondroprotection drug/Viartril-s was used as the control in the other hospital. Intervention was carried out over a period of 4 weeks. Primary outcome measures included self-reported pain level, and changes in stiffness and functional ability as measured by the Western Ontario McMaster Universities Osteoarthritis (WOMAC index. Mixed models were used for statistical analysis. Substantial improvements in disease-specific symptoms were observed, after 4 weeks of treatment, in patients taking BNHS capsules. As assessed by the WOMAC index, pain level of the BNHS group decreased by 57% [95% confidence interval (CI = 50, 63], stiffness by 63% (95% CI = 55, 71 and functional ability increased by 56% (95% CI = 50, 63. No significant differences were found in any of the outcome measures between the BNHS group and either of the comparison groups. No severe adverse effects were reported. However, this study lacked a placebo group; therefore, we conclude that BNHS appears to be as effective as commonly prescribed medicines for the relief of pain and dysfunction in knee osteoarthritis patients, but costs a lot less than other Western and herbal drugs in the study.

  9. Design of Endoscopic Capsule With Multiple Cameras.

    Science.gov (United States)

    Gu, Yingke; Xie, Xiang; Li, Guolin; Sun, Tianjia; Wang, Dan; Yin, Zheng; Zhang, Pengfei; Wang, Zhihua

    2015-08-01

    In order to reduce the miss rate of the wireless capsule endoscopy, in this paper, we propose a new system of the endoscopic capsule with multiple cameras. A master-slave architecture, including an efficient bus architecture and a four level clock management architecture, is applied for the Multiple Cameras Endoscopic Capsule (MCEC). For covering more area of the gastrointestinal tract wall with low power, multiple cameras with a smart image capture strategy, including movement sensitive control and camera selection, are used in the MCEC. To reduce the data transfer bandwidth and power consumption to prolong the MCEC's working life, a low complexity image compressor with PSNR 40.7 dB and compression rate 86% is implemented. A chipset is designed and implemented for the MCEC and a six cameras endoscopic capsule prototype is implemented by using the chipset. With the smart image capture strategy, the coverage rate of the MCEC prototype can achieve 98% and its power consumption is only about 7.1 mW.

  10. Capsule Shields the Function of Short Bacterial Adhesins

    OpenAIRE

    Schembri, Mark A.; Dalsgaard, Dorte; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can occur in other gram-negative bacteria. Likewise, we show that other short adhesins exemplified by the AIDA-I protein are blocked by the presence of a capsule. The results support the notion that cap...

  11. Forensic identification of CITES protected slimming cactus (Hoodia) using DNA barcoding.

    Science.gov (United States)

    Gathier, Gerard; van der Niet, Timotheus; Peelen, Tamara; van Vugt, Rogier R; Eurlings, Marcel C M; Gravendeel, Barbara

    2013-11-01

    Slimming cactus (Hoodia), found only in southwestern Africa, is a well-known herbal product for losing weight. Consequently, Hoodia extracts are sought-after worldwide despite a CITES Appendix II status. The failure to eradicate illegal trade is due to problems with detecting and identifying Hoodia using morphological and chemical characters. Our aim was to evaluate the potential of molecular identification of Hoodia based on DNA barcoding. Screening of nrITS1 and psbA-trnH DNA sequences from 26 accessions of Ceropegieae resulted in successful identification, while conventional chemical profiling using DLI-MS led to inaccurate detection and identification of Hoodia. The presence of Hoodia in herbal products was also successfully established using DNA sequences. A validation procedure of our DNA barcoding protocol demonstrated its robustness to changes in PCR conditions. We conclude that DNA barcoding is an effective tool for Hoodia detection and identification which can contribute to preventing illegal trade. © 2013 American Academy of Forensic Sciences.

  12. Moisture diffusion and permeability characteristics of hydroxypropylmethylcellulose and hard gelatin capsules.

    Science.gov (United States)

    Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie

    2015-01-30

    The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Utilization of the capsule out-pile test facilities(2000-2003)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Oh, J. M.; Cho, Y. G. and others

    2003-06-01

    Two out-pile test facilities were installed and being utilized for the non-irradiation tests outside the HANARO. The names of the facilities are the irradiation equipment design verification test facilities and the one-channel flow test device. In these facilities, the performance test of all capsules manufactured before loading in the HANARO and the design verification test for newly developed capsules were performed. The tests in these facilities include loading/unloading, pressure drop, endurance and vibration test etc. of capsules. In the period 2000{approx}2003, the performance tests for 8 material capsules of 99M-01K{approx}02M-05U were carried out, and the design verification tests of creep and fuel capsules developed newly were performed. For development of the creep capsule, pressure drop measurement, operation test of heater, T/C, LVDT and stress loading test were performed. In the design stage of the fuel capsule, the endurance and vibration test besides the above mentioned tests were carried out for verification of the safe operation during irradiation test in the HANARO. And in-chimeny bracket and the capsule supporting system were fixed and the flow tubes and the handling tools were manufactured for use at the facilities.

  14. Respiratory disorders in paediatric age: orthodontic diagnosis and treatment in dysmetabolic obese children and allergic slim children.

    Science.gov (United States)

    Favero, L; Arreghini, A; Cocilovo, F; Favero, V

    2013-09-01

    Obesity and allergic susceptibility are worsening problems in the most industrialised countries. With different mechanisms, they both lead to a deterioration of children's life quality because they affect the respiratory system, leading to asthma and respiratory disorders such as mouth breathing and obstructive sleep apnoea. The latter are related to specific types of malocclusions that require an early diagnosis and specific multidisciplinary treatment. The purpose of this work is to show the characteristic signs and symptoms of these disorders in children of the two phenotypes (allergic and slim, obese and dysmetabolic). Intercepting such issues allows both pediatricians and paediatric dentists to refer the child to a multidisciplinary team of specialists able to deal, in a holistic way, with both the physical and behavioural causes, and also with the consequences on systemic and craniofacial development in particular. The literature available on this topic in the years between 1997 and 2011 was reviewed, paying special attention to prevention, paediatric visits, diagnostic tools and treatment options for each of the two conditions. Dysmetabolic obese children and allergic slim children have specific respiratory problems during rest and exercise. Mouth breathing and obstructive sleep apnoea are due to an abnormal craniofacial development and can cause serious systemic problems in adulthood. Intercepting early signs of pathognomonic symptoms of sleep aponea and mouth breathing permits to treat children with an early multidisciplinary approach, and allows for proper physical and psychological development of the child.

  15. Scanning Laser Infrared Molecular Spectrometer (SLIMS)

    Science.gov (United States)

    Scott, David C.; Rickey, Kelly; Ksendzov, Alexander; George, Warren P.; Aljabri, Abdullah S.; Steinkraus, Joel M.

    2012-01-01

    This prototype innovation is a novel design that achieves very long, effective laser path lengths that are able to yield ppb (parts per billion) and sub-ppb measurements of trace gases. SLIMS can also accommodate multiple laser channels covering a wide range of wavelengths, resulting in detection of more chemicals of interest. The mechanical design of the mirror cell allows for the large effective path length within a small footprint. The same design provides a robust structure that lends itself to being immune to some of the alignment challenges that similar cells face. By taking a hollow cylinder and by cutting an elliptically or spherically curved surface into its inner wall, the basic geometry of a reflecting ring is created. If the curved, inner surface is diamond-turned and highly polished, a surface that is very highly reflective can be formed. The surface finish can be further improved by adding a thin chrome or gold film over the surface. This creates a high-quality, curved, mirrored surface. A laser beam, which can be injected from a small bore hole in the wall of the cylinder, will be able to make many low-loss bounces around the ring, creating a large optical path length. The reflecting ring operates on the same principle as the Herriott cell. The difference exists in the mirror that doesn't have to be optically aligned, and which has a relatively large, internal surface area that lends itself to either open air or evacuated spectroscopic measurements. This solid, spherical ring mirror removes the possibility of mirror misalignment caused by thermal expansion or vibrations, because there is only a single, solid reflecting surface. Benefits of the reflecting ring come into play when size constraints reduce the size of the system, especially for space missions in which mass is at a premium.

  16. Development of Multiple Capsule Robots in Pipe

    Directory of Open Access Journals (Sweden)

    Shuxiang Guo

    2018-05-01

    Full Text Available Swallowable capsule robots which travel in body cavities to implement drug delivery, minimally invasive surgery, and diagnosis have provided great potential for medical applications. However, the space constraints of the internal environment and the size limitations of the robots are great challenges to practical application. To address the fundamental challenges of narrow body cavities, a different-frequency driven approach for multiple capsule robots with screw structure manipulated by external electromagnetic field is proposed in this paper. The multiple capsule robots are composed of driven permanent magnets, joint permanent magnets, and a screw body. The screw body generates a propulsive force in a fluidic environment. Moreover, robots can form new constructions via mutual docking and release. To provide manipulation guidelines for active locomotion, a dynamic model of axial propulsion and circumferential torque is established. The multiple start and step-out frequencies for multiple robots are defined theoretically. Moreover, the different-frequency driven approach based on geometrical parameters of screw structure and the overlap angles of magnetic polarities is proposed to drive multiple robots in an identical electromagnetic field. Finally, two capsule robots were prototyped and experiments in a narrow pipe were conducted to verify the different motions such as docking, release, and cooperative locomotion. The experimental results demonstrated the validity of the driven approach for multiple capsule robots in narrow body cavities.

  17. Dynamic computed tomography of hepatocellular carcinoma with particular reference to capsule

    Energy Technology Data Exchange (ETDEWEB)

    Otsuji, Hideaki [Nara Prefectural Hospital (Japan); Uchida, Hideo; Ohishi, H

    1983-11-01

    Dynamic CT of 117 hepatocellular carcinoma was analyzed about the capsule. Capsules were detected in 57 cases (49%) and they were classified into three types. The tumor showed high density during 15 to 26 sec after bolus injection of conrast medium, but the capsule was not enhanced. Incidence of the capsule enhanced as ring high density was 73% during 37 to 90 sec and over 90% after 4 min. Dynamic CT was very useful in the elucidation of hemodynamics of capsules of hepatocellular carcinoma.

  18. Results from annual testing of ARECO cesium capsules from 1990-1994

    Energy Technology Data Exchange (ETDEWEB)

    Lundeen, J.E.

    1994-10-01

    The purpose of this report is to compile the results of the cesium capsule inspections and testing at the Applied Radiant Energy Corporation (ARECO) facility in Lynchburg, VA, performed in 1990, 1991, 1992, 1993, and 1994. The 25 cesium capsules at the ARECO facility were visually identified and clunk tested. A Go/No Go gauge test was required for capsules failing the clunk test. A visual inspection of capsules was required for the initial testing (1990). All 25 capsules passed the inspections and testing each year.

  19. Update on scribe–cleave–passivate (SCP) slim edge technology for silicon sensors: Automated processing and radiation resistance

    Energy Technology Data Exchange (ETDEWEB)

    Fadeyev, V., E-mail: fadeyev@ucsc.edu [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Ely, S.; Galloway, Z.; Ngo, J.; Parker, C.; Sadrozinski, H.F.-W. [Santa Cruz Institute for Particle Physics, University of California, Santa Cruz, CA 95064 (United States); Christophersen, M.; Phlips, B.F. [U.S. Naval Research Laboratory, Code 7654, 4555 Overlook Avenue, Southwest Washington, DC 20375 (United States); Pellegrini, G.; Rafi, J.M.; Quirion, D. [Instituto de Microelectrónica de Barcelona, IMB-CNM-CSIC, Bellaterra, Barcelona (Spain); Dalla Betta, G.-F. [INFN and University of Trento, Via Sommarive, 14, 38123 Povo di Trento (Italy); Boscardin, M. [Fondazione Bruno Kessler, Via Sommarive, 18, 38123 Povo di Trento (Italy); Casse, G. [Department of Physics, University of Liverpool, O. Lodge Laboratory, Oxford Street, Liverpool L69 7ZE (United Kingdom); Gorelov, I.; Hoeferkamp, M.; Metcalfe, J.; Seidel, S. [Department of Physics and Astronomy, University of New Mexico, MSC 07 4220, 1919 Lomas Boulevard NE, Albuquerque, NM 87131 (United States); Gaubas, E.; Ceponis, T. [Institute of Applied Research, Vilnius University, Sauletekio 9, LT-10222 Vilnius (Lithuania); and others

    2014-11-21

    We pursue scribe–cleave–passivate (SCP) technology for making “slim edge” sensors. The goal is to reduce the inactive region at the periphery of the devices while maintaining their performance. In this paper we report on two aspects of the current efforts. The first one involves fabrication options for mass production. We describe the automated cleaving tests and a simplified version of SCP post-processing of n-type devices. Another aspect is the radiation resistance of the passivation. We report on the radiation tests of n- and p-type devices with protons and neutrons.

  20. High-gain capsule design for the HIDIF project

    International Nuclear Information System (INIS)

    Honrubia, J.J.; Cerrada, J.A.; Gomez, R.

    2000-01-01

    A high-gain capsule has been designed for the HIDIF project. The goal has been to relax the accelerator requirements by using a radiation pulse with lower peak temperature (220 eV) than previous designs (260 eV). The ablator material is beryllium doped with a very low concentration (0.2 atom %) of copper. The capsule absorbs 1.3 MJ and yields, approximately, 450 MJ in I-D simulations. The effect of the opacity of the ablator on capsule performance has been studied in detail. (authors)

  1. Treatment of Common Cold Patients with the Shi-Cha Capsule: A Multicenter, Double-Blind, Randomized, Placebo-Controlled, Dose-Escalation Trial

    Science.gov (United States)

    Chang, Jing; Dong, Shou-Jin; She, Bin; Zhang, Rui-Ming; Meng, Mao-Bin; Xu, Yan-Ling; Wan, Li-Ling; Shi, Ke-Hua; Pan, Jun-Hun; Mao, Bing

    2012-01-01

    This study was designed to determine the therapeutic efficacy and safety of the Shi-cha capsule, a Chinese herbal formula, in the treatment of patients with wind-cold type common cold. In our multi-center, prospective, double-blind, randomized, placebo-controlled, dose-escalation trial, patients with wind-cold type common cold received 0.6 g of Shi-cha capsule plus 0.6 g placebo (group A), 1.2 g of Shi-cha capsule (group B), or 1.2 g placebo (group C), three times daily for 3 days and followed up to 10 days. The primary end point was all symptom duration. The secondary end points were main symptom duration, minor symptom duration, the changes in cumulative symptom score, main symptom score, and minor symptom score 4 days after the treatment, as well as adverse events. A total of 377 patients were recruited and 360 met the inclusive criteria; 120 patients constituted each treatment group. Compared with patients in group C, patients in groups A and B had significant improvement in the all symptom duration, main symptom duration, minor symptom duration, as well as change from baseline of cumulative symptom score, main symptom score, and minor symptom score at day 4. The symptom durations and scores showed slight superiority of group B over group A, although these differences were not statistically significant. There were no differences in adverse events. The Shi-cha capsule is efficacious and safe for the treatment of patients with wind-cold type common cold. Larger trials are required to fully assess the benefits and safety of this treatment for common cold. PMID:23346193

  2. Capsule endoscopy in the diagnosis of Crohn’s disease

    Directory of Open Access Journals (Sweden)

    Niv Y

    2013-05-01

    Full Text Available Yaron NivDepartment of Gastroenterology, Rabin Medical Center, Tel Aviv University, Petah Tikva, IsraelAbstract: Crohn’s disease is a chronic inflammatory disorder affecting any part of the gastrointestinal tract, but frequently involves the small and large bowel. Typical presenting symptoms include abdominal pain and diarrhea. Patients with this disorder may also have extraintestinal manifestations, including arthritis, uveitis, and skin lesions. The PillCam™SB capsule is an ingestible disposable video camera that transmits high quality images of the small intestinal mucosa. This enables the small intestine to be readily accessible to physicians investigating for the presence of small bowel disorders, such as Crohn’s disease. Four meta-analyses have demonstrated that capsule endoscopy identifies Crohn’s disease when other methods are not helpful. It should be noted that it is the best noninvasive procedure for assessing mucosal status, but is not superior to ileocolonoscopy, which remains the gold standard for assessment of ileocolonic disease. Mucosal healing along the small bowel can only be demonstrated by an endoscopic procedure such as capsule endoscopy. Achievement of long-term mucosal healing has been associated with a trend towards a decreased need for hospitalization and a decreased requirement for corticosteroid treatment in patients with Crohn’s disease. Recently, we have developed and validated the Capsule Endoscopy Crohn’s Disease Activity Index (also known as the Niv score for Crohn’s disease of the small bowel. The next step is to expand our score to the colon, and to determine the role and benefit of a capsule endoscopy activity score in patients suffering from Crohn’s ileocolitis and/or colitis. This scoring system will also serve to improve our understanding of the impact of capsule endoscopy, and therefore treatment, on the immediate outcome of this disorder. As the best procedure available for assessing

  3. Capsule Development and Utilization for Material Irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, B. G.; Joo, K. N.

    2003-05-01

    The objective of this project was to establish basic capsule irradiation technology using the multi-purpose research reactor [HANARO] to eventually support national R and D projects of advanced fuel and materials related to domestic nuclear power plants and next generation reactors. There are several national nuclear projects in KAERI, which require several irradiation tests to investigate in-pile behavior of nuclear reactor fuel and materials for the R and D of several types of fuels such as advanced PWR and DUPIC fuels and for the R and D of structural materials such as RPV(reactor pressure vessel) steel, Inconel, zirconium alloy, and stainless steel. At the moment, internal and external researchers in institutes, industries and universities are interested in investigating the irradiation characteristics of materials using the irradiation facilities of HANARO. For these kinds of material irradiation tests, it is important to develop various capsules using our own techniques. The development of capsules requires several leading-edge technologies and our own experiences related to design and fabrication. In the second phase from April 1,2000 to March 31, 2003, the utilization technologies were developed using various sensors for the measurements of temperature, pressure and displacement, and instrumented capsule technologies for the required fuel irradiation tests were developed. In addition, the improvement of the existing capsule technologies and the development of an in-situ measurable creep capsule for specific purposes were done to meet the various requirements of users

  4. Crosslinking studies in gelatin capsules treated with formaldehyde and in capsules exposed to elevated temperature and humidity.

    Science.gov (United States)

    Ofner, C M; Zhang, Y E; Jobeck, V C; Bowman, B J

    2001-01-01

    Incomplete in vitro capsule shell dissolution and subsequent drug release problems have recently received attention. A modified USP dissolution method was used to follow capsule shell dissolution, and a 2,4,6-trinitrobenzenesulfonic acid (TNBS) assay was used to follow loss of epsilon-amino groups to study this shell dissolution problem postulated to be due to gelatin crosslinking. The dissolution problems were simulated using hard gelatin capsule (HGC) shells previously treated with formaldehyde to crosslink the gelatin. These methods were also used to study the effect of uncrosslinked HGC stored under stressed conditions (37 degrees C and 81% RH) with or without the presence of soft gelatin capsule shells (SGC). A 120 ppm formaldehyde treatment reduced gelatin shell dissolution to 8% within 45 min in water at 37 degrees C. A 200 ppm treatment reduced gelatin epsilon-amino groups to 83% of the original uncrosslinked value. The results also support earlier reports of non-amino group crosslinking by formaldehyde in gelatin. Under stressed conditions, HGC stored alone showed little change over 21 weeks. However, by 12 to 14 weeks, the HGC exposed to SGC showed a 23% decrease in shell dissolution and an 8% decrease in the number of epsilon-amino groups. These effects on the stressed HGC are ascribed to a volatile agent from SGC shells, most likely formaldehyde, that crosslinked nearby HGC shells. This report also includes a summary of the literature on agents that reduce gelatin and capsule shell dissolution and the possible mechanisms of this not-so-simple problem. Copyright 2001 Wiley-Liss, Inc. and the American Pharmaceutical Association J Pharm Sci 90: 79-88, 2001

  5. Traditional Chinese Medicine for Refractory Nephrotic Syndrome: Strategies and Promising Treatments

    Science.gov (United States)

    Tu, Yuan-Chao

    2018-01-01

    Refractory nephrotic syndrome (RNS) is an immune-related kidney disease with poor clinical outcomes. Standard treatments include corticosteroids as the initial therapy and other immunosuppressants as second-line options. A substantial proportion of patients with RNS are resistant to or dependent on immunosuppressive drugs and often experience unremitting edema and proteinuria, cycles of remission and relapse, and/or serious adverse events due to long-term immunosuppression. Traditional Chinese medicine has a long history of treating complicated kidney diseases and holds great potential for providing effective treatments for RNS. This review describes the Chinese medical theories relating to the pathogenesis of RNS and discusses the strategies and treatment options using Chinese herbal medicine. Available preclinical and clinical evidence strongly supports the integration of traditional Chinese medicine and Western medicine for improving the outcome of RNS. Herbal medicine such as Astragalus membranaceus, Stephania tetrandra S. Moore, and Tripterygium wilfordii Hook F can serve as the alternative therapy when patients fail to respond to immunosuppression or as the complementary therapy to improve therapeutic efficacy and reduce side effects of immunosuppressive agents. Wuzhi capsules (Schisandra sphenanthera extract) with tacrolimus and tetrandrine with corticosteroids are two herb-drug combinations that have shown great promise and warrant further studies. PMID:29507594

  6. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    Science.gov (United States)

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  7. Triggered Release from Polymer Capsules

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Kahn, Aaron P. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Odom, Susan A. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry; Sottos, Nancy R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Materials Science and Engineering; White, Scott R. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Aerospace Engineering; Moore, Jeffrey S. [Univ. of Illinois, Urbana, IL (United States). Beckman Inst. for Advanced Science and Technology and Dept. of Chemistry

    2011-07-06

    Stimuli-responsive capsules are of interest in drug delivery, fragrance release, food preservation, and self-healing materials. Many methods are used to trigger the release of encapsulated contents. Here we highlight mechanisms for the controlled release of encapsulated cargo that utilize chemical reactions occurring in solid polymeric shell walls. Triggering mechanisms responsible for covalent bond cleavage that result in the release of capsule contents include chemical, biological, light, thermal, magnetic, and electrical stimuli. We present methods for encapsulation and release, triggering methods, and mechanisms and conclude with our opinions on interesting obstacles for chemically induced activation with relevance for controlled release.

  8. Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2: 2013 protocols.

    Science.gov (United States)

    Bing, Sen; Chen, Kang; Hou, Hong; Zhang, Weijuan; Li, Linyi; Wei, Jiao; Shu, Chang; Wan, Yi

    2016-04-01

    This study aimed to determine the accuracy of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors according to the European Society of Hypertension International Protocol revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols. The devices were assessed on 33 participants according to the European Society of Hypertension requirements and were then tested on 85 participants according to the ANSI/AAMI/ISO 81060-2:2013 criteria. Procedures and data analysis were carried out following protocol guidelines precisely. The Microlife BP A200 Comfort and W2 Slim devices passed the criteria of the European Society of Hypertension International Protocol revision 2010 for both systolic blood pressure and diastolic blood pressure. The devices also fulfilled the ANSI/AAMI/ISO 81060-2:2013 criteria, with mean differences of SBP and DPB between the devices and observers of 0.38±5.12 and 0.28±4.29 mmHg for the BP A200 Comfort and 1.01±6.80 and 0.34±5.62 mmHg for the W2 Slim, respectively. The Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors fulfilled the European Society of Hypertension revision 2010 and the ANSI/AAMI/ISO 81060-2:2013 protocols, and can be recommended for self-measurement in the general population.

  9. What we have learned and what to expect from capsule endoscopy.

    Science.gov (United States)

    Adler, Samuel N; Bjarnason, Ingvar

    2012-10-16

    Capsule endoscopy was conceived by Gabriel Iddan and Paul Swain independently two decades ago. These applications include but are not limited to Crohn's disease of the small bowel, occult gastrointestinal bleeding, non steroidal anti inflammatory drug induced small bowel disease, carcinoid tumors of the small bowel, gastro intestinal stromal tumors of the small bowel and other disease affecting the small bowel. Capsule endoscopy has been compared to traditional small bowel series, computerized tomography studies and push enteroscopy. The diagnostic yield of capsule endoscopy has consistently been superior in the diagnosis of small bowel disease compared to the competing methods (small bowel series, computerized tomography, push enteroscopy) of diagnosis. For this reason capsule endoscopy has enjoyed a meteoric success. Image quality has been improved with increased number of pixels, automatic light exposure adaptation and wider angle of view. Further applications of capsule endoscopy of other areas of the digestive tract are being explored. The increased transmission rate of images per second has made capsule endoscopy of the esophagus a realistic possibility. Technological advances that include a double imager capsule with a nearly panoramic view of the colon and a variable frame rate adjusted to the movement of the capsule in the colon have made capsule endoscopy of the colon feasible. The diagnostic rate for the identification of patients with polyps equal to or larger than 6 mm is high. Future advances in technology and biotechnology will lead to further progress. Capsule endoscopy is following the successful modern trend in medicine that replaces invasive tests with less invasive methodology.

  10. An exploration of therapeutic evaluation of traditional Chinese medicine in treatment of hepatic fibrosis

    Directory of Open Access Journals (Sweden)

    XU Lieming

    2017-05-01

    Full Text Available China has become one of the leading counties in the world to treat hepatic fibrosis with Chinese patent drugs. The therapeutic effect of traditional Chinese medicine (TCM should be evaluated from the aspects of short-term therapeutic effect, long-term therapeutic effect, and effect of relief of symptoms. This article introduces the results of our exploration of the application of liver stiffness measurement to evaluate therapeutic effect, five-year survival rate to assess long-term therapeutic effect, and a “TCM syndrome scale” to evaluate effect of relief of symptoms, suggesting that the Chinese patent drug Fuzheng Huayu capsules/tablets have a marked clinical effect in the treatment of hepatic fibrosis. It is recommended to use serological diagnostic models, conduct prospective studies with long-term follow-up, and analyze the samples and data accumulated over a long period of time, in order to perfect the methods for evaluating the outcome of hepatic fibrosis.

  11. Safety evaluation for packaging (onsite) singly encapsulated cesium chloride capsules

    International Nuclear Information System (INIS)

    Smyth, W.W.

    1997-01-01

    Three nonstandard Waste Encapsulation and Storage Facility (WESF) cesium chloride capsules are being shipped from WESF (225B building) to the 324 building. They would normally be shipped in the Beneficial Uses Shipping System (BUSS) cask under its US Department of Energy (DOE) license (DOE 1996), but these capsules are nonstandard: one has a damaged or defective weld in the outer layer of encapsulation, and two have the outer encapsulation removed. The 3 capsules, along with 13 other capsules, will be overpacked in the 324 building to meet the requirements for storage in WESF's pool

  12. Capsule shields the function of short bacterial adhesins

    DEFF Research Database (Denmark)

    Schembri, Mark; Dalsgaard, D.; Klemm, Per

    2004-01-01

    Bacterial surface structures such as capsules and adhesins are generally regarded as important virulence factors. Here we demonstrate that capsules block the function of the self-recognizing protein antigen 43 through physical shielding. The phenomenon is not restricted to Escherichia coli but can...

  13. Toward an integrated model of capsule regulation in Cryptococcus neoformans.

    Directory of Open Access Journals (Sweden)

    Brian C Haynes

    2011-12-01

    Full Text Available Cryptococcus neoformans is an opportunistic fungal pathogen that causes serious human disease in immunocompromised populations. Its polysaccharide capsule is a key virulence factor which is regulated in response to growth conditions, becoming enlarged in the context of infection. We used microarray analysis of cells stimulated to form capsule over a range of growth conditions to identify a transcriptional signature associated with capsule enlargement. The signature contains 880 genes, is enriched for genes encoding known capsule regulators, and includes many uncharacterized sequences. One uncharacterized sequence encodes a novel regulator of capsule and of fungal virulence. This factor is a homolog of the yeast protein Ada2, a member of the Spt-Ada-Gcn5 Acetyltransferase (SAGA complex that regulates transcription of stress response genes via histone acetylation. Consistent with this homology, the C. neoformans null mutant exhibits reduced histone H3 lysine 9 acetylation. It is also defective in response to a variety of stress conditions, demonstrating phenotypes that overlap with, but are not identical to, those of other fungi with altered SAGA complexes. The mutant also exhibits significant defects in sexual development and virulence. To establish the role of Ada2 in the broader network of capsule regulation we performed RNA-Seq on strains lacking either Ada2 or one of two other capsule regulators: Cir1 and Nrg1. Analysis of the results suggested that Ada2 functions downstream of both Cir1 and Nrg1 via components of the high osmolarity glycerol (HOG pathway. To identify direct targets of Ada2, we performed ChIP-Seq analysis of histone acetylation in the Ada2 null mutant. These studies supported the role of Ada2 in the direct regulation of capsule and mating responses and suggested that it may also play a direct role in regulating capsule-independent antiphagocytic virulence factors. These results validate our experimental approach to dissecting

  14. Non-destructive tests of capsules for JMTR irradiation examination

    International Nuclear Information System (INIS)

    Tanaka, Hidetaka; Nagao, Yoshiharu; Sato, Masashi; Osawa, Kenji

    2007-03-01

    Irradiation examination are increasing in advanced irradiation research for accurate prediction control and evaluation of irradiation parameter such as neutron fluence, etc. by using JMTR. Irradiation capsule internals are therefore structurally complicated recently. This report described the procedure of non destructive tests such as radiographic test, penetrant test, ultrasonic test, etc. for inspection of irradiation capsules in JMTR, and the result of Test-case of confirmation procedure for internal parts of irradiation capsules. (author)

  15. Regional Variation Is Present in Elbow Capsules after Injury

    OpenAIRE

    Germscheid, Niccole M.; Hildebrand, Kevin A.

    2006-01-01

    Myofibroblast numbers and α-smooth muscle actin expression are increased in anterior joint capsules of patients with posttraumatic elbow contractures. The purpose of our study was to determine whether these changes occur regionally or throughout the entire joint capsule. We hypothesized that the α-smooth muscle actin mRNA expression and the myofibroblast numbers in posterior joint capsules would be elevated in elbows obtained from patients with posttraumatic joint contractures compared with j...

  16. SATCAP-C : a program for thermal hydraulic design of pressurized water injection type capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Asoh, Tomokazu; Niimi, Motoji

    1992-10-01

    There are capsules called 'Pressure Water Injection Type Capsule' as a kind of irradiation devices at the Japan Materials Testing Reactor (JMTR). A type of the capsules is a 'Boiling Water Capsule' (usually named BOCA). The other type is a 'Saturated Temperature Capsule' (named SATCAP). When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature so far as the water does not fully change to steam. These type capsules are designed on the basis of the conception of applying the water characteristic to the control of irradiation temperature of specimens in the capsules. In designing of the capsules in which the pressurized water is injected, thermal performances have to be understood as exactly as possible. It is not easy however to predict thermal performances such as axially temperature distribution of water injected in the capsule, because there are heat-sinks at both side of inner and outer of capsule casing as the result that the water is fluid. Then, a program (named SATCAP-C) for the BOCA and SATCAP was compiled to grasp the thermal performances in the capsules and has been used the design of the capsules and analysis of the data obtained from some actual irradiation capsules. It was confirmed that the program was effective in thermal analysis for the capsules. The analysis found out the values for heat transfer coefficients at various surfaces of capsule components and some thermal characteristics of capsules. (author)

  17. Simulations of indirectly driven gas-filled capsules at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Weber, S. V.; Casey, D. T.; Eder, D. C.; Pino, J. E.; Smalyuk, V. A.; Remington, B. A.; Rowley, D. P.; Yeamans, C. B.; Tipton, R. E.; Barrios, M.; Benedetti, R.; Berzak Hopkins, L.; Bleuel, D. L.; Bond, E. J.; Bradley, D. K.; Caggiano, J. A.; Callahan, D. A.; Cerjan, C. J.; Clark, D. S.; Divol, L. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2014-11-15

    Gas-filled capsules imploded with indirect drive on the National Ignition Facility have been employed as symmetry surrogates for cryogenic-layered ignition capsules and to explore interfacial mix. Plastic capsules containing deuterated layers and filled with tritium gas provide a direct measure of mix of ablator into the gas fuel. Other plastic capsules have employed DT or D{sup 3}He gas fill. We present the results of two-dimensional simulations of gas-filled capsule implosions with known degradation sources represented as in modeling of inertial confinement fusion ignition designs; these are time-dependent drive asymmetry, the capsule support tent, roughness at material interfaces, and prescribed gas-ablator interface mix. Unlike the case of cryogenic-layered implosions, many observables of gas-filled implosions are in reasonable agreement with predictions of these simulations. Yields of TT and DT neutrons as well as other x-ray and nuclear diagnostics are matched for CD-layered implosions. Yields of DT-filled capsules are over-predicted by factors of 1.4–2, while D{sup 3}He capsule yields are matched, as well as other metrics for both capsule types.

  18. The first capsule implosion experiments on Orion

    International Nuclear Information System (INIS)

    Garbett, W J; Horsfield, C J; Gales, S G; Leatherland, A E; Rubery, M S; Coltman, J E; Meadowcroft, A E; Rice, S J; Simons, A J; Woolhead, V E

    2016-01-01

    Direct drive capsule implosions are being developed on the Orion laser at AWE as a platform for ICF and HED physics experiments. The Orion facility combines both long pulse and short-pulse beams, making it well suited for studying the physics of alternative ignition approaches. Orion implosions also provide the opportunity to study aspects of polar direct drive. Limitations on drive symmetry from the relatively small number of laser beams makes predictive modelling of the implosions challenging, resulting in some uncertainty in the expected capsule performance. Initial experiments have been fielded to evaluate baseline capsule performance and inform future design optimization. Highly promising DD fusion neutron yields in excess of 10 9 have been recorded. Results from the experiments are presented alongside radiation-hydrocode modelling. (paper)

  19. [Academic discussion of adverse reaction of clinical trials of new traditional Chinese medicines and relevant influencing factors].

    Science.gov (United States)

    Wang, Wen-ping; Yu, Ming; Wang, Li; Jiang, Xi-ren; Li, Xiao-bin; Wang, Hua-wei; Cao, Ying; Liu, Kai; Huang, Lu-qi

    2015-01-01

    Data of clinical trial projects involved by clinical trial institutions certified by the State Food and Drug Administration from 2002 to November 2012 were collected to summarize adverse reactions in project summary/statistical reports, analyze the rate of adverse reactions of clinical trials of new traditional Chinese medicines and relevant influencing factors, and increase the awareness of the safety of new traditional Chinese medicines. A total of 73 050 cases in 209 projects of 14 specialties were collected, including 49 689 cases in the new traditional Chinese medicine group and 271 adverse reaction cases, with an incidence rate of adverse reactions at 0.55%. The adverse reaction rate in 3 months 0.63% for injection > 0.50% for oral. In the administration of only the test drug, the adverse reaction rate of patches was the highest (2.68%), whereas that of aerosols and suppositories was lowest (0). In the combined administration of the test drug and the simulation agent, the adverse reaction rate of external test patch + capsule was the highest (3.38%), whereas that of capsule + oral liquid, pills + granules, tablets + oral liquid, tablets + pills, tablet + capsule was the lowest (0). In the administration of only the test drug, the adverse reaction rate was 0.47%; In the combined administration with simulation agent (drug volume increase), the adverse reaction rate was 0.74%. Different doses caused adverse reaction different rates; The adverse reaction rate of drugs with whole-course dose between 1 100-1 200 g was the highest (3.36%), that for whole-course doses of 500-600, 900-1 000, 1 400-1 500, 1 600-1 700, 1 800-1 900 g was the lowest (0). In conclusion, the adverse reaction rate of new traditional Chinese medicines was still up to 0.55%, with the adverse reaction rate between 0.47% and 0.72% over the 11 years, without significant difference in each year. The adverse reaction rate was closely related to course of treatment, approach of administration

  20. Residual mercury content and leaching of mercury and silver from used amalgam capsules.

    Science.gov (United States)

    Stone, M E; Pederson, E D; Cohen, M E; Ragain, J C; Karaway, R S; Auxer, R A; Saluta, A R

    2002-06-01

    The objective of this investigation was to carry out residual mercury (Hg) determinations and toxicity characteristic leaching procedure (TCLP) analysis of used amalgam capsules. For residual Hg analysis, 25 capsules (20 capsules for one brand) from each of 10 different brands of amalgam were analyzed. Total residual Hg levels per capsule were determined using United States Environmental Protection Agency (USEPA) Method 7471. For TCLP analysis, 25 amalgam capsules for each of 10 brands were extracted using a modification of USEPA Method 1311. Hg analysis of the TCLP extracts was done with USEPA Method 7470A. Analysis of silver (Ag) concentrations in the TCLP extract was done with USEPA Method 6010B. Analysis of the residual Hg data resulted in the segregation of brands into three groups: Dispersalloy capsules, Group A, retained the most Hg (1.225 mg/capsule). These capsules were the only ones to include a pestle. Group B capsules, Valliant PhD, Optaloy II, Megalloy and Valliant Snap Set, retained the next highest amount of Hg (0.534-0.770 mg/capsule), and were characterized by a groove in the inside of the capsule. Group C, Tytin regular set double-spill, Tytin FC, Contour, Sybraloy regular set, and Tytin regular set single-spill retained the least amount of Hg (0.125-0.266 mg/capsule). TCLP analysis of the triturated capsules showed Sybraloy and Contour leached Hg at greater than the 0.2 mg/l Resource Conservation and Recovery Act (RCRA) limit. This study demonstrated that residual mercury may be related to capsule design features and that TCLP extracts from these capsules could, in some brands, exceed RCRA Hg limits, making their disposal problematic. At current RCRA limits, the leaching of Ag is not a problem.

  1. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Versatile Loading of Diverse Cargo into Functional Polymer Capsules.

    Science.gov (United States)

    Richardson, Joseph J; Maina, James W; Ejima, Hirotaka; Hu, Ming; Guo, Junling; Choy, Mei Y; Gunawan, Sylvia T; Lybaert, Lien; Hagemeyer, Christoph E; De Geest, Bruno G; Caruso, Frank

    2015-02-01

    Polymer microcapsules are of particular interest for applications including self-healing coatings, catalysis, bioreactions, sensing, and drug delivery. The primary way that polymer capsules can exhibit functionality relevant to these diverse fields is through the incorporation of functional cargo in the capsule cavity or wall. Diverse functional and therapeutic cargo can be loaded into polymer capsules with ease using polymer-stabilized calcium carbonate (CaCO 3 ) particles. A variety of examples are demonstrated, including 15 types of cargo, yielding a toolbox with effectively 500+ variations. This process uses no harsh reagents and can take less than 30 min to prepare, load, coat, and form the hollow capsules. For these reasons, it is expected that the technique will play a crucial role across scientific studies in numerous fields.

  3. Method of forming capsules containing a precise amount of material

    Science.gov (United States)

    Grossman, M.W.; George, W.A.; Maya, J.

    1986-06-24

    A method of forming a sealed capsule containing a submilligram quantity of mercury or the like, the capsule being constructed from a hollow glass tube, by placing a globule or droplet of the mercury in the tube. The tube is then evacuated and sealed and is subsequently heated so as to vaporize the mercury and fill the tube therewith. The tube is then separated into separate sealed capsules by heating spaced locations along the tube with a coiled heating wire means to cause collapse spaced locations there along and thus enable separation of the tube into said capsules. 7 figs.

  4. Iodometric determination of ampicillin in proprietary capsules | Ejele ...

    African Journals Online (AJOL)

    The concentration of ampicillin in ampicillin capsule preparations purchased in Owerri main market, Imo State of Nigeria, was determined using the iodometric titration method. The results showed that the ampicillin concentrations in the capsules contained between 250 and 260 mg/cap of ampicillin trihydrate. Statistical ...

  5. Video-based measurements for wireless capsule endoscope tracking

    International Nuclear Information System (INIS)

    Spyrou, Evaggelos; Iakovidis, Dimitris K

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions. (paper)

  6. Video-based measurements for wireless capsule endoscope tracking

    Science.gov (United States)

    Spyrou, Evaggelos; Iakovidis, Dimitris K.

    2014-01-01

    The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.

  7. Yangjing Capsule Ameliorates Spermatogenesis in Male Mice Exposed to Cyclophosphamide

    Directory of Open Access Journals (Sweden)

    Hongle Zhao

    2015-01-01

    Full Text Available Yangjing capsule (YC, a traditional Chinese compound herbal preparation, has been proven as an effective drug to improve spermatogenesis in clinical practice. However, its pharmacological mechanisms were not fully clarified. This study was designed to investigate the protective effects of YC on spermatogenesis in the mouse model of spermatogenesis dysfunction induced by cyclophosphamide (CP. The administration of YC significantly increased the epididymal index, sperm count, and sperm motility of model mice. Histopathological changes demonstrated that CP caused obvious structural damage to testis, which were reversed by the administration of YC. Results from TUNEL assay showed that treatment with YC dramatically decreased the apoptosis of spermatogenic cell induced by CP. Moreover, YC treatment could inhibit the mRNA and protein expression of Bax to Bcl-2 and also raised expression of AR at both mRNA and protein levels. These data suggest that YC might ameliorate spermatogenesis in male mice exposed to CP through inhibiting the apoptosis of spermatogenic cell and enhancing the actions of testosterone in spermatogenesis.

  8. Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.

    Science.gov (United States)

    Mapara, Sanyat S; Patravale, Vandana B

    2017-09-10

    The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been

  9. SLIM-MAUD: an approach to assessing human error probabilities using structured expert judgment. Volume II. Detailed analysis of the technical issues

    International Nuclear Information System (INIS)

    Embrey, D.E.; Humphreys, P.; Rosa, E.A.; Kirwan, B.; Rea, K.

    1984-07-01

    This two-volume report presents the procedures and analyses performed in developing an approach for structuring expert judgments to estimate human error probabilities. Volume I presents an overview of work performed in developing the approach: SLIM-MAUD (Success Likelihood Index Methodology, implemented through the use of an interactive computer program called MAUD-Multi-Attribute Utility Decomposition). Volume II provides a more detailed analysis of the technical issues underlying the approach

  10. Bowman Capsulitis Predicts Poor Kidney Allograft Outcome in T Cell-Mediated Rejection.

    Science.gov (United States)

    Gallan, Alexander J; Chon, W James; Josephson, Michelle A; Cunningham, Patrick N; Henriksen, Kammi J; Chang, Anthony

    2018-02-28

    Acute T cell-mediated rejection (TCMR) is an important cause of renal allograft loss. The Banff classification for tubulointerstitial (type I) rejection is based on the extent of both interstitial inflammation and tubulitis. Lymphocytes may also be present between parietal epithelial cells and Bowman capsules in this setting, which we have termed "capsulitis." We conducted this study to determine the clinical significance of capsulitis. We identified 42 patients from the pathology archives at the University of Chicago with isolated Banff type I TCMR from 2010-2015. Patient demographic data, Banff classification, and graft outcome measurements were compared between capsulitis and non-capsulitis groups using Mann-Whitney U test. Capsulitis was present in 26 (62%), and was more frequently seen in Banff IB than IA TCMR (88% vs 44%, P=.01). Patients with capsulitis had a higher serum creatinine at biopsy (4.6 vs 2.9mg/dL, P=.04) and were more likely to progress to dialysis (42% vs 13%, P=.06) with fewer recovering their baseline serum creatinine (12% vs 38%, P=.08). Patients with both Banff IA TCMR and capsulitis have clinical outcomes similar or possibly worse than Banff IB TCMR compared to those with Banff IA and an absence of capsulitis. Capsulitis is an important pathologic parameter in the evaluation of kidney transplant biopsies with potential diagnostic, prognostic, and therapeutic implications in the setting of TCMR. Copyright © 2018. Published by Elsevier Inc.

  11. The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules

    Science.gov (United States)

    Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko

    2016-03-01

    The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.

  12. Alginate/sodium caseinate aqueous-core capsules: a pH-responsive matrix.

    Science.gov (United States)

    Ben Messaoud, Ghazi; Sánchez-González, Laura; Jacquot, Adrien; Probst, Laurent; Desobry, Stéphane

    2015-02-15

    Alginate capsules have several applications. Their functionality depends considerably on their permeability, chemical and mechanical stability. Consequently, the creation of composite system by addition of further components is expected to control mechanical and release properties of alginate capsules. Alginate and alginate-sodium caseinate composite liquid-core capsules were prepared by a simple extrusion. The influence of the preparation pH and sodium caseinate concentration on capsules physico-chemical properties was investigated. Results showed that sodium caseinate influenced significantly capsules properties. As regards to the membrane mechanical stability, composite capsules prepared at pH below the isoelectric point of sodium caseinate exhibited the highest surface Young's modulus, increasing with protein content, explained by potential electrostatic interactions between sodium caseinate amino-groups and alginate carboxylic group. The kinetic of cochineal red A release changed significantly for composite capsules and showed a pH-responsive release. Sodium caseinate-dye mixture studied by absorbance and fluorescence spectroscopy confirmed complex formation at pH 2 by electrostatic interactions between sodium caseinate tryptophan residues and cochineal red sulfonate-groups. Consequently, the release mechanism was explained by membrane adsorption process. This global approach is useful to control release mechanism from macro and micro-capsules by incorporating guest molecules which can interact with the entrapped molecule under specific conditions. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Analysis of lomustine drug content in FDA-approved and compounded lomustine capsules.

    Science.gov (United States)

    KuKanich, Butch; Warner, Matt; Hahn, Kevin

    2017-02-01

    OBJECTIVE To determine the lomustine content (potency) in compounded and FDA-approved lomustine capsules. DESIGN Evaluation study. SAMPLE 2 formulations of lomustine capsules (low dose [7 to 11 mg] and high dose [40 to 48 mg]; 5 capsules/dose/source) from 3 compounders and from 1 manufacturer of FDA-approved capsules. PROCEDURES Lomustine content was measured by use of a validated high-pressure liquid chromatography method. An a priori acceptable range of 90% to 110% of the stated lomustine content was selected on the basis of US Pharmacopeia guidelines. RESULTS The measured amount of lomustine in all compounded capsules was less than the stated content (range, 59% to 95%) and was frequently outside the acceptable range (failure rate, 2/5 to 5/5). Coefficients of variation for lomustine content ranged from 4.1% to 16.7% for compounded low-dose capsules and from 1.1% to 10.8% for compounded high-dose capsules. The measured amount of lomustine in all FDA-approved capsules was slightly above the stated content (range, 104% to 110%) and consistently within the acceptable range. Coefficients of variation for lomustine content were 0.5% for low-dose and 2.3% for high-dose FDA-approved capsules. CONCLUSIONS AND CLINICAL RELEVANCE Compounded lomustine frequently did not contain the stated content of active drug and had a wider range of lomustine content variability than did the FDA-approved product. The sample size was small, and larger studies are needed to confirm these findings; however, we recommend that compounded veterinary formulations of lomustine not be used when appropriate doses can be achieved with FDA-approved capsules or combinations of FDA-approved capsules.

  14. Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.

    Science.gov (United States)

    Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha

    2016-01-01

    Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.

  15. Irradiation capsules VISA-2a-f, chapter VI

    International Nuclear Information System (INIS)

    Pavicevic, M.

    1962-01-01

    Irradiation capsules VISA-2a, b,c,d, and e were constructed in Saclay according to the drawings from Vinca and according to the demand of the experimentators. This chapter VI includes documentation for each type of capsule, review about each experiment within the VISA-2 project, the objective and purpose of the experiment as well as experimental device. Irradiation capsule VISA-2f was placed in the RA reactor core in September 1962. It was completely manufactured in Vinca including sample holders and leak tight shells. It will remain in the reactor core for about month in order to obtain the integral fast neutron flux [sr

  16. Some views on mechanical safety of capsules for radioactive waste

    International Nuclear Information System (INIS)

    Nilsson, F.

    1978-02-01

    Three different concepts for encapsulation of used nuclear fuel are discussed with respect to their mechanical safety. In the first concept the burnt out fuel elements are encapsulated into a copper capsule. The material properties of copper are discussed especially with reference to toughness and creep. A simple fracture mechanical analysis shows that the risk for direct fracture is negligible at the actual stress levels. The loads on the capsule are studied and are found to be normally less than 40 MPa (residual stresses). Transient loads that might arise in the handling of the capsule might however be dangerous to its integrity. The next concept is encapsulation of the fuel elements into a sintered aluminium oxide capsule. A fracture probability analysis based on Weibull's statistical fracture theory gives fracture probabilities that are acceptable. Extended studies of this concept, especially of the risk for delayed fracture, is recommended. The last concept is a Pb-Ti capsule for glassed refined fuel. An analysis of the relaxation of internal stresses is performed. The critical point of these capsules appears to be the welds on the titanium shell where the risk for a direct fracture is not neglibigle

  17. Quantitative evaluation of in vitro effects and interactions of active fractions in a Chinese medicinal formula (Yaotongning Capsule) on rat chondrocytes.

    Science.gov (United States)

    Zhang, Li-Guo; Ouyang, Xiao-Wen; Wu, Ting-Ting; Ni, Li-Jun; Shi, Wan-Zhong

    2014-09-29

    Yaotongning Capsule (YTNC) is a Traditional Chinese Medicinal (TCM) formula that has been demonstrated to be effective for osteoarthritis (OA) treatment in clinical use. Many compounds and 10 component medicinal materials (CMMs for short, i.e., the fundamental elements used in TCM formulas) in YTNC are challenging to study the pharmacological effects and interactions of the CMMs. Besides, it is difficult to know whether the YTNC formula is reasonable, and if YTNC formula could be improved without comparing YTNC with other TCM formulas of treating OA. Based on different combinations of the active fractions from the 10 CMMs of YTNC and eight additional herbs frequently used in the TCM formulas of treating OA, the present study evaluated systematically the in vitro effects of these active fractions and the interactions among the active fractions from YTNC on rat chondrocytes to find possible solutions of the above questions. Based on the formulation of YTNC and the concept of combinatorial chemistry, the active fractions were applied to form the whole YTNC prescription (i.e., the combination of all YTNC active fractions and the extract of YTNC׳s vehicle), five disassembled formulas of YTNC (i.e., the combinations of some active fractions in YTNC) and 21 TCM samples consisted of different kinds of active fractions. The degenerated chondrocytes were induced with interleukin-1β (IL-1β), and then the half-effective concentration (EC50) value of the proliferation activity was analyzed to evaluate the 27 TCM samples. Nine samples were screened for the following evaluation on glycosaminoglycan (GAG) synthesis. Rat articular cartilage was obtained from six Sprague-Dawley rats (seven days of age), and then chondrocytes were isolated through enzymatic digestion with 0.2% Collagenase II. Proliferations of chondrocytes were examined through Cell Counting Kit-8 assay, when the intracellular levels of GAG were detected by 1,9-Dimethylmethylene blue staining. The interactions

  18. The Antiphagocytic Activity of SeM of Streptococcus equi Requires Capsule.

    Science.gov (United States)

    Timoney, John F; Suther, Pranav; Velineni, Sridhar; Artiushin, Sergey C

    2014-01-01

    Resistance to phagocytosis is a crucial virulence property of Streptococcus equi (Streptococcus equi subsp. equi; Se), the cause of equine strangles. The contribution and interdependence of capsule and SeM to killing in equine blood and neutrophils were investigated in naturally occurring strains of Se. Strains CF32, SF463 were capsule and SeM positive, strains Lex90, Lex93 were capsule negative and SeM positive and strains Se19, Se1-8 were capsule positive and SeM deficient. Phagocytosis and killing of Se19, Se1-8, Lex90 and Lex93 in equine blood and by neutrophils suspended in serum were significantly (P ≤ 0.02) greater compared to CF32 and SF463. The results indicate capsule and SeM are both required for resistance to phagocytosis and killing and that the anti-phagocytic property of SeM is greatly reduced in the absence of capsule.

  19. Membrane support of accelerated fuel capsules for inertial fusion energy reactors

    International Nuclear Information System (INIS)

    Petzoldt, R.W.; Moir, R.W.

    1993-01-01

    The use of a thin membrane to suspend an (inertial fusion energy) fuel capsule in a holder for injection into a reactor chamber is investigated. Capsule displacement and membrane deformation angle are calculated for an axisymmetric geometry for a range of membrane strain and capsule size. This information is used to calculate maximum target accelerations. Membranes must be thin (perhaps of order one micron) to minimize their effect on capsule implosion symmetry. For example, a 5 μm thick cryogenic mylar membrane is calculated to allow 1,000 m/s 2 acceleration of a 3 mm radius, 100 mg capsule. Vibration analysis (for a single membrane support) shows that if membrane vibration is not deliberately minimized, allowed acceleration may be reduced by a factor of four. A two membrane alternative geometry would allow several times greater acceleration. Therefore, alternative membrane geometry's should be used to provide greater target acceleration potential and reduce capsule displacement within the holder (for a given membrane thickness)

  20. Experimental Investigation of the Spiral Structure of a Magnetic Capsule Endoscope

    Directory of Open Access Journals (Sweden)

    Wanan Yang

    2016-06-01

    Full Text Available Fitting a wireless capsule endoscope (WCE with a navigation feature can maximize its functional benefits. The rotation of a spiral-type capsule can be converted to translational motion. The study investigated how the spiral structure and rotational speed affected the capsule's translation speed. A hand-held instrument, including two permanent magnets, a stepper motor, a controller and a power supplier, were designed to generate rotational magnetic fields. The surfaces of custom-built permanent magnet rings magnetized radially were mounted in spiral lines with different lead angles and diameters, acting as mock-up capsules. The experimental results demonstrate that the rotational speed of the magnetic field and the spiral have significant effects on the translational speed of a capsule. The spiral line with a larger lead angle and the rotating magnetic field with a higher speed can change the capsule's rotation into a translational motion more efficiently in the intestine.

  1. A Standardized Traditional Chinese Medicine Preparation Named Yejuhua Capsule Ameliorates Lipopolysaccharide-Induced Acute Lung Injury in Mice via Downregulating Toll-Like Receptor 4/Nuclear Factor-κB

    Directory of Open Access Journals (Sweden)

    Chu-Wen Li

    2015-01-01

    Full Text Available A standardized traditional Chinese medicine preparation named Yejuhua capsule (YJH has been clinically used in treatments of various acute respiratory system diseases with high efficacy and low toxicity. In this study, we were aiming to evaluate potential effects and to elucidate underlying mechanisms of YJH against lipopolysaccharide- (LPS- induced acute lung injury (ALI in mice. Moreover, the chemical analysis and chromatographic fingerprint study were performed for quality evaluation and control of this drug. ALI was induced by intratracheal instillation of LPS (5 mg/kg into the lung in mice and dexamethasone (5 mg/kg, p.o. was used as a positive control drug. Results demonstrated that pretreatments with YJH (85, 170, and 340 mg/kg, p.o. effectively abated LPS-induced histopathologic changes, attenuated the vascular permeability enhancement and edema, inhibited inflammatory cells migrations and protein leakages, suppressed the ability of myeloperoxidase, declined proinflammatory cytokines productions, and downregulated activations of nuclear factor-κB (NF-κB and expressions of toll-like receptor 4 (TLR4. This study demonstrated that YJH exerted potential protective effects against LPS-induced ALI in mice and supported that YJH was a potential therapeutic drug for ALI in clinic. And its mechanisms were at least partially associated with downregulations of TLR4/NF-κB pathways.

  2. Effect of Heat Flux on the Specimen Temperature of an LBE Capsule

    International Nuclear Information System (INIS)

    Kang, Y. H.; Park, S. J.; Cho, M. S.; Choo, K. N.; Lee, Y. S.

    2011-01-01

    For application of high-temperature irradiation tests in the HANARO reactor for Gen IV reactor material development, a number of newly designed LBE capsules have been investigated at KAERI since 2008. Recent study on heat transfer experiment of an LBE capsule with a single heater has shown that the specimen temperature of the mock-up increased linearly with an increase of heat input. The work highlighted only the heat transfer capability of an LBE capsule with a single heater as a simulated specimen in a liquid metal medium. Hence, a new LBE capsule with multi specimen sets has been designed and fabricated for the heat transfer experiment of an LBE capsule of 11M-01K. In this paper, a series of thermal analyses and heat transfer experiments for a newly designed LBE capsule was implemented to study the effect of an increase in the value of heat input and its influence on temperature distribution in the capsule mock-up

  3. Adhesive capsulitis of the shoulder: evaluation with MR arthrography

    International Nuclear Information System (INIS)

    Jung, Joon-Yong; Jee, Won-Hee; Chun, Ho Jong; Kim, Yang-Soo; Chung, Yang Guk; Kim, Jung-Man

    2006-01-01

    The purpose of this study was to determine the usefulness of magnetic resonance (MR) arthrography for diagnosing adhesive capsulitis. Shoulder MR images of 28 patients with (n=14) and without (n=14) adhesive capsulitis were retrospectively analyzed. MR images were assessed for capsule and synovium thickness as well as the width of the axillary recess on oblique coronal fat-suppressed T1-weighted images and T2-weighted images, respectively. On oblique sagittal fat-suppressed T1-weighted images, the width of the rotator interval and the presence of abnormal tissue in the interval were evaluated. Significant differences were found between the two groups in capsule and synovium thickness on both sides of the recess on oblique coronal T2-weighted images (P=0.000), whereas thickness on the humeral aspect showed no significant difference on oblique coronal fat-suppressed T1-weighted images (P=0.109). On oblique coronal T2-weighted images, a cut-off value of 3-mm thickness gave the highest diagnostic accuracy for adhesive capsulitis with sensitivity, specificity, and accuracy of 79% (11/14), 100% (14/14), and 89% (25/28) at the humeral side and 93% (13/14), 86% (12/14), and 89% (25/28) at the glenoid side, respectively. There were significant differences in rotator interval width, presence of abnormal tissue in the rotator interval, and axillary recess width between the two groups (P<0.05). Thickness of capsule and synovium of the axillary recess greater than 3 mm is a practical MR criterion for diagnosing adhesive capsulitis when measured on oblique coronal T2-weighted MR arthrography images without fat suppression. The presence of abnormal tissue in the rotator interval showed high sensitivity but rather low specificity. (orig.)

  4. Wireless powered capsule endoscopy for colon diagnosis and treatment

    International Nuclear Information System (INIS)

    Chen, Wenwen; Yan, Guozheng; He, Shu; Ke, Quan; Wang, Zhiwu; Liu, Hua; Jiang, Pingping

    2013-01-01

    This paper presents a wireless power transfer system integrated with an active locomotion and biopsy module in an endoscopic capsule for colon inspection. The capsule, which can move automatically, is designed for non-invasive biopsy and visual inspection of the intestine. To supply enough power for multiple functions and ensure safety for the human body, the efficiency of the current power transmission system needs to be improved. To take full advantage of the volume in the capsule body, a novel structure of receiving coils wound on a multi-core of MnZn ferrite hollow cylinder was used; with this new core, the efficiency increased to more than 7.98%. Up to 1.4 W of dc power can be delivered to the capsule as it travels along the gastrointestinal tract. Three micro motors were integrated for pumping, anchoring, locomotion and biopsy. A user interface and RF communication enables the operator to drive the capsule in an intuitive manner. To gauge the efficacy of the wireless power supply in a simulated real-world application, the biopsy and locomotion capabilities of the device were successfully tested in a slippery, soft tube and gut environment in vitro. (paper)

  5. Chord length distribution for a compound capsule

    International Nuclear Information System (INIS)

    Pitřík, Pavel

    2017-01-01

    Chord length distribution is a factor important in the calculation of ionisation chamber responses. This article describes Monte Carlo calculations of the chord length distribution for a non-convex compound capsule. A Monte Carlo code was set up for generation of random chords and calculation of their lengths based on the input number of generations and cavity dimensions. The code was written in JavaScript and can be executed in the majority of HTML viewers. The plot of occurrence of cords of different lengths has 3 peaks. It was found that the compound capsule cavity cannot be simply replaced with a spherical cavity of a triangular design. Furthermore, the compound capsule cavity is directionally dependent, which must be taken into account in calculations involving non-isotropic fields of primary particles in the beam, unless equilibrium of the secondary charged particles is attained. (orig.)

  6. Comparative assessment of hepatic Glisson's capsule and bovine pericardium in heart valve bioprostheses.

    Science.gov (United States)

    Kagramanov, I I; Kokshenev, I V; Dobrova, N B; Kastava, V T; Serov, R A; Zaets, S B

    1998-05-01

    The optimal material for heart valve bioprostheses remains disputable. This investigation was initiated to compare the properties of hepatic Glisson's capsule, clinical experience of which in cardiovascular surgery is minimal, with those of bovine pericardium. Hepatic Glisson's capsule was harvested from bull calves and used to create composite pulmonary arterial monocusp grafts and bioprostheses. Comparison of the strength and elastic properties of Glisson's capsule and bovine pericardium, as well as the hydrodynamic characteristics of valves made from these materials, was performed. Late results of operations using these materials were estimated echocardiographically. Although Glisson's capsule tissue is thinner than the bovine pericardium, its elasticity modulus is greater. However, the hydrodynamic characteristics of heart valves made from either tissue are similar. Moreover, valves made from Glisson's capsule have a lower systolic pressure gradient on the prosthesis and a higher effective orifice area. Composite pulmonary arterial xenopericardial grafts with a monocusp of Glisson's capsule were used in 30 patients during tetralogy of Fallot repair. Glisson's capsule was also used for tricuspid valve reconstruction and as a bioprosthesis in six patients with Ebstein's anomaly. At 1-2 years after surgery, the Glisson's capsule tissue remained thin and flexible, with no calcification. Although the hydrodynamic properties of hepatic Glisson's capsule and the bovine pericardium are similar, the capsule tissue is thinner and has a greater elasticity modulos. Thus, Glisson's capsule may be used for bioprosthesis construction both independently and in combination with bovine pericardium.

  7. Harmonic Coupling Analysis of a Multi-Drive System with Slim DC-link Drive

    DEFF Research Database (Denmark)

    Yang, Feng; Kwon, Jun Bum; Blaabjerg, Frede

    2017-01-01

    One of the problems with slim dc-link adjustable speed drive is the difficulties to analyze the harmonic coupling when it is integrated into a multi-drive system. The traditional methods analyze this harmonic issue by neglecting the harmonic coupling, and base on the linear time-invariant methods....... Its disadvantages include the time consumption and large computer memory. This paper proposes to do harmonic analysis by using the harmonic state-space modeling method by using the linear time-periodic theory. By using the proposed model, the harmonic couplings, between dc-link and point of common...... coupling in different drives, are all analyzed in the multi-drive system. In the meantime, the effects of the small film dc-link capacitance and the nonlinear characteristic of the diode rectifier are considered. The detailed modeling procedure, the simulations and the lab experiment on a two-drive system...

  8. Capsule Performance Optimization for the National Ignition Facility

    Science.gov (United States)

    Landen, Otto

    2009-11-01

    The overall goal of the capsule performance optimization campaign is to maximize the probability of ignition by experimentally correcting for likely residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. This will be accomplished using a variety of targets that will set key laser, hohlraum and capsule parameters to maximize ignition capsule implosion velocity, while minimizing fuel adiabat, core shape asymmetry and ablator-fuel mix. The targets include high Z re-emission spheres setting foot symmetry through foot cone power balance [1], liquid Deuterium-filled ``keyhole'' targets setting shock speed and timing through the laser power profile [2], symmetry capsules setting peak cone power balance and hohlraum length [3], and streaked x-ray backlit imploding capsules setting ablator thickness [4]. We will show how results from successful tuning technique demonstration shots performed at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design meet the required sensitivity and accuracy. We will also present estimates of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors, and show that these get reduced after a number of shots and iterations to meet an acceptable level of residual uncertainty. Finally, we will present results from upcoming tuning technique validation shots performed at NIF at near full-scale. Prepared by LLNL under Contract DE-AC52-07NA27344. [4pt] [1] E. Dewald, et. al. Rev. Sci. Instrum. 79 (2008) 10E903. [0pt] [2] T.R. Boehly, et. al., Phys. Plasmas 16 (2009) 056302. [0pt] [3] G. Kyrala, et. al., BAPS 53 (2008) 247. [0pt] [4] D. Hicks, et. al., BAPS 53 (2008) 2.

  9. Thermal analysis of an instrumented capsule using an ANSYS program

    International Nuclear Information System (INIS)

    Choi, Myoung Hwan; Choo, Kee Nam; Kang, Young Hwan; Cho, Man Soon; Sohn, Jae Min; Kim, Bong Goo

    2006-01-01

    An instrumented capsule has been used for an irradiation test of various nuclear materials in the research reactor, HANARO. To obtain the design data of the instrumented capsule, a thermal analysis is performed using a finite element analysis program, ANSYS. The 2-dimensional model for a cross section of the capsule including the specimens is generated, and a gamma-heating rate of the materials for the HANARO power of 24 or 30 MW is considered as an input force. The effect of the gap size and the control rod position on the temperature of the specimens or other components is discussed. From the analysis it is found that the gap between the thermal media and the external tube has a significant effect on the temperature of the specimen. In the case of the material capsule, the maximum temperature for the reactor power of 24 MW is 255degC for an irradiation test and 257degC for a FE analysis at the center stage of the capsule in the axial direction. It is expected that the analysis models using an ANSYS program will be useful in designing the instrumented capsules for an irradiation test and estimating the test results. (author)

  10. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    International Nuclear Information System (INIS)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J.

    2008-12-01

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials

  11. Therapeutic applications of radioactive 131iodine: Procedures and incidents with capsules

    International Nuclear Information System (INIS)

    Al Aamri, Marwa; Ravichandran, Ramamoorthy; Binukumar, John Pichy; Al Balushi, Naima

    2016-01-01

    Treatments for thyrotoxicosis and carcinoma thyroid are carried out by oral administration of radioactive iodine ( 131 I) in the form of liquid or capsules. The liquid form of 131 I has higher risk factors such as vapourization, spillage and need for management of higher activity wastes. Use of 131 I in capsule form simplify procedures of handling compared to liquid form of 131 I. The guidelines of safe handling and quality assurance aspects for therapeutic use 131 I are well outlined by International Atomic Energy Agency (IAEA) reports. A few unusual incidents with I-131 capsules encountered in the past need to be highlighted from health physics point of view. In Royal Hospital, Oman, I-131 is imported in capsules, and the total activity handled/year steadily increased over 10 years. Discrete activities range from 185 MBq (5 mCi) up to 7.4 GBq (200 mCi). In four incidents deviations in standard operational procedures were recorded. Nature of incidents is described as follows: (1) After assay of activity, the capsule was directly put in the lead container with missing of inner cap. (2) Patient poured water in the Perspex tube, when the capsule was handed over to her, making an emergency situation. (3) In 3 high activity capsules (2 nos 2.96 GBq, 1 no. 4.26 GBq), observed sticky behavior in capsule holder on the 2 nd day post receipt, which were in order on the 1 st day. (4) A capsule could not be swallowed by a patient, which was taken back from the mouth. Monitoring of patient later did not show residual ingested activity. The report documents some of the unusual incidents for information to other centers engaged in such radioactive administrations

  12. Myofibroblast Numbers are Elevated in Human Elbow Capsules After Trauma

    OpenAIRE

    Hildebrand, Kevin A.; Zhang, Mei; van Snellenberg, Wistara; King, Graham J. W.; Hart, David A.

    2004-01-01

    Elbow contractures, a frequent problem after injury, can be treated by excision of the joint capsule. However, the underlying changes in the joint capsule are poorly understood. Based on skin healing work, we examined the hypotheses that myofibroblast numbers and expression of a myofibroblast marker α-smooth muscle actin, are elevated in patients with posttraumatic joint contractures. Anterior capsules were obtained from six patients who had operative release of posttraumatic contractures gre...

  13. Fabrication of Non-instrumented capsule for DUPIC simulated fuel irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.G.; Kang, Y.H.; Park, S.J.; Shin, Y.T. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In order to develope DUPIC nuclear fuel, the irradiation test for simulated DUPIC fuel was planed using a non-instrumented capsule in HANARO. Because DUPIC fuel is highly radioactive material the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO was designed to remotely assemble and disassemble in hot cell. And then, according to the design requirements the non-instrumented DUPIC capsule was successfully manufactured. Also, the manufacturing technologies of the non-instrumented capsule for irradiating the nuclear fuel in HANARO were established, and the basic technology for the development of the instrumented capsule technology was accumulated. This report describes the manufacturing of the non-instrumented capsule for simulated DUPIC fuel. And, this report will be based to develope the instrumented capsule, which will be utilized to irradiate the nuclear fuel in HANARO. 26 refs., 4 figs. (Author)

  14. Associations Between Egg Capsule Morphology and Predation Among Populations of the Marine Gastropod, Nucella emarginata.

    Science.gov (United States)

    Rawlings, T A

    1990-12-01

    Intraspecific variation in the morphology of egg capsules is ideal for assessing the costs and benefits of encapsulation, yet little is known about the extent of such variation among populations of a single species. In the present study, I compared capsule morphology among three populations of the intertidal gastropod, Nucella emarginata. Significant differences were found both in capsule wall thickness and capsule strength. Mean capsule wall thickness varied as much as 25% among populations, with the dry weight of capsular cases differing accordingly. Capsule strength, measured as resistance to puncturing and squeezing forces, also varied among populations, but did not directly reflect differences in capsule wall thickness. Despite extensive variation in capsule morphology within this species, the number and size of eggs contained within capsules of equal volume did not differ significantly among populations. I also compared the type of capsule-eating predators that were present at each site. Shore crabs, Hemigrapsus spp., were abundant at all three sites; however, the predatory isopods Idotea wosnesenskii were only present at sites containing relatively thick-walled capsules. Although Hemigrapsus and Idotea were able to chew through both thick- and thin-walled capsules, laboratory experiments revealed that Idotea preferentially opened thin-walled capsules. These results suggest that variation in capsule morphology among populations of N. emarginata may, at least in part, reflect selection for the protection of embryos against predation.

  15. Factors affecting capsule size and production by lactic acid bacteria used as dairy starter cultures.

    Science.gov (United States)

    Hassan, A N; Frank, J F; Shalabi, S I

    2001-02-28

    The effects of sugar substrates on capsule size and production by some capsule-forming nonropy and ropy dairy starter cultures were studied. Test sugars (glucose, lactose, galactose, or sucrose) were used as a sole carbohydrate source and the presence of a capsule and its size were determined by using confocal scanning laser microscopy. Nonropy strains produced maximum capsule size when grown in milk. Strains that did not produce capsules in milk did not produce them in any other growth medium. Specific sugars required for capsule production were strain-dependent. Increasing lactose content of Elliker broth from 0.5 to 5% or adding whey protein or casein digest produced larger capsules. Whey protein concentrate stimulated production of larger capsules than did casamino acids or casitone. Some Streptococcus thermophilus strains produced capsules when grown on galactose only. Nonropy strains of Lactobacillus delbrueckii subsp. bulgaricus produced capsules on lactose, but not on glucose. A ropy strain of Lactobacillus delbrueckii subsp. bulgaricus produced a constant capsule size regardless of the growth medium. The ability of some strains of Streptococcus thermophilus to use galactose in capsule production could reduce browning of mozzarella cheese during baking by removing a source of reducing sugar. Media that do not support capsule production may improve cell harvesting.

  16. First beryllium capsule implosions on the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kline, J. L.; Yi, S. A.; Simakov, A. N.; Olson, R. E.; Wilson, D. C.; Kyrala, G. A.; Perry, T. S.; Batha, S. H.; Zylstra, A. B. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Dewald, E. L.; Tommasini, R.; Ralph, J. E.; Strozzi, D. J.; MacPhee, A. G.; Callahan, D. A.; Hinkel, D. E.; Hurricane, O. A.; Milovich, J. L.; Rygg, J. R.; Khan, S. F. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); and others

    2016-05-15

    The first indirect drive implosion experiments using Beryllium (Be) capsules at the National Ignition Facility confirm the superior ablation properties and elucidate possible Be-ablator issues such as hohlraum filling by ablator material. Since the 1990s, Be has been the preferred Inertial Confinement Fusion (ICF) ablator because of its higher mass ablation rate compared to that of carbon-based ablators. This enables ICF target designs with higher implosion velocities at lower radiation temperatures and improved hydrodynamic stability through greater ablative stabilization. Recent experiments to demonstrate the viability of Be ablator target designs measured the backscattered laser energy, capsule implosion velocity, core implosion shape from self-emission, and in-flight capsule shape from backlit imaging. The laser backscatter is similar to that from comparable plastic (CH) targets under the same hohlraum conditions. Implosion velocity measurements from backlit streaked radiography show that laser energy coupling to the hohlraum wall is comparable to plastic ablators. The measured implosion shape indicates no significant reduction of laser energy from the inner laser cone beams reaching the hohlraum wall as compared with plastic and high-density carbon ablators. These results indicate that the high mass ablation rate for beryllium capsules does not significantly alter hohlraum energetics. In addition, these data, together with data for low fill-density hohlraum performance, indicate that laser power multipliers, required to reconcile simulations with experimental observations, are likely due to our limited understanding of the hohlraum rather than the capsule physics since similar multipliers are needed for both Be and CH capsules as seen in experiments.

  17. Potential of sago starch/carrageenan mixture as gelatin alternative for hard capsule material

    Science.gov (United States)

    Poeloengasih, Crescentiana Dewi; Pranoto, Yudi; Anggraheni, Frida Dwi; Marseno, Djagal Wiseso

    2017-03-01

    In order to replace gelatin in capsule shell production, blends of sago starch and carrageenan were developed. Films and capsules were prepared with 10% (w/v) of sago starch, 25% (w/w starch) of glycerol and various carrageenan concentration (1, 2, 3% w/w starch) in two different kappa/iota-carrageenan ratio (1:3 and 3:1). The resulted films and capsules were characterized by mechanical property, water vapor and oxygen permeability. In addition, moisture absorption and solubility of capsule in acid solution were investigated. The results reveal that addition of carrageenan makes the films stronger and less permeable. Higher kappa-carrageenan content improved tensile strength and barrier properties of the films, whereas higher iota-carrageenan content produced films with higher elongation, moisture absorption and capsule solubility in acid solution. Capsule with 2% (w/w starch) of carrageenan at kappa-/iota-ratio 3:1 had the lowest moisture absorption, whereas capsule with 3% (w/w starch) of carrageenan at kappa/iota ratio 1:3 had the highest solubility. It is illustrated that sago starch/carrageenan blends can be used as hard capsule material.

  18. Learning to Diagnose Cirrhosis with Liver Capsule Guided Ultrasound Image Classification

    Directory of Open Access Journals (Sweden)

    Xiang Liu

    2017-01-01

    Full Text Available This paper proposes a computer-aided cirrhosis diagnosis system to diagnose cirrhosis based on ultrasound images. We first propose a method to extract a liver capsule on an ultrasound image, then, based on the extracted liver capsule, we fine-tune a deep convolutional neural network (CNN model to extract features from the image patches cropped around the liver capsules. Finally, a trained support vector machine (SVM classifier is applied to classify the sample into normal or abnormal cases. Experimental results show that the proposed method can effectively extract the liver capsules and accurately classify the ultrasound images.

  19. Improvement and utilization of irradiation capsule technology in HANARO

    International Nuclear Information System (INIS)

    Choo, Kee-Nam; Cho, Man-Soon; Kim, Bong-Goo; Lee, Cheol-Yong; Yang, Sung-Woo; Shin, Yoon-Taek; Park, Seng-Jae; Jung, Hoan-Sung

    2012-01-01

    Several improvements of irradiation capsule technology regarding irradiation test parameters, such as temperature and neutron flux/fluence, and regarding instrumentation have progressed at HANARO since the last KAERI-JAERI joint seminar held in 2008. The standard HANARO capsule technology that was developed for use in a commercial power plant temperature of about 300degC was improved to apply to a temperature range of 100-1000degC for the irradiation test of materials of new research reactors and future nuclear systems. Low-flux and long-term irradiation technologies have been developed at HANARO. As a beginning step of the localization of capsule instrumentation technology, the irradiation performance of a domestically produced thermocouple and LVDT will be examined at HANARO. The accuracy of an evaluation of neutron fluence and precise welding technology are also being examined at HANARO. Based on these accumulated capsule technologies, a HANARO irradiation capsule system is being actively utilized for the national R and D programme on commercial nuclear reactors and nuclear fuel cycle technology in Korea. HANARO has recently started the irradiation support of R and D relevant to future nuclear systems including SMART, VHTR, and SFR, and HANARO is preparing new support relevant to new research and Fusion reactors. (author)

  20. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    International Nuclear Information System (INIS)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  1. Thermohydraulic design of saturated temperature capsule for IASCC irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ide, Hiroshi; Matsui, Yoshinori; Itabashi, Yukio [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment] [and others

    2002-10-01

    An advanced water chemistry controlled irradiation research device is being developed in JAERI, to perform irradiation tests for irradiation assisted stress corrosion cracking (IASCC) research concerned with aging of LWR. This device enables the irradiation tests under the water chemistry condition and the temperature, which simulate the conditions for BWR core internals. The advanced water chemistry controlled irradiation research device is composed of saturated temperature capsule inserted into the JMTR core and the water chemistry control unit installed in the reactor building. Regarding the saturated temperature capsule, the Thermohydraulic design of capsule structure was done, aimed at controlling the specimen's temperature, feeding water velocity on specimen's surface to the environment of BWR nearer. As the result of adopting the new capsule structure based on the design study, it was found out that feeding water velocity at the surface of specimen's is increased to about 10 times as much as before, and nuclear heat generated in the capsule components can be removed safely even in the abnormal event such as the case of loss of feeding water. (author)

  2. Adhesive capsulitis: contrast-enhansed shoulder MRI findings

    International Nuclear Information System (INIS)

    Gokalp, Gokhan; Yildirim, Nalan; Yazici, Zeynep; Algin, Oktay

    2011-01-01

    Full text: Evaluation of contrast-enhanced magnetic resonance imaging (CE-MRI) findings in cases clinically diagnosed as adhesive capsulitis (AC). CE-MRI images of 12 cases diagnosed as AC (13 shoulder joints) and nine control cases were retrospectively evaluated. AC diagnosis was establlished based on the history and clinical symptoms. MR signal intensity changes in the axillary pouch, rotator interval, biceps anchor and anterior posterior capsules were analysed with regard to the presence of abnormal soft tissue and contrast enhancement. Capsular and synovial thickening were measured in the axillary recess and rotator interval on coronal oblique CE T1-weighted images. Patient and control groups were compared by Fisher's exact and McNemar tests in terms of signal intensity changes and contrast enhancement in the described areas. Results: Comparison of the group with AC and the control group regarding intensity changes showed a statistically significant difference in the axillary pouch (P 0.05). Comparison of AC and control groups in terms of contrast enhancement revealed statistically significant differences in the axillary pouch, rotator interval, biceps anchor and anterior-posterior capsules (P < 0.001). A significant difference was determined between the AC and control groups with regard to thickening in axillary pouch and rotator interval (P < 0.001). CE studies are useful for diagnosis of AC as it demonstrates thickening of specific soft-tissue areas like joint capsule and synovium.

  3. Criteria for cesium capsules to be shipped as special form radioactive material

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this report is to compile all the documentation which defines the criteria for Waste Encapsulation and Storage Facility (WESF) cesium capsules at the IOTECH facility and Applied Radiant Energy Corporation (ARECO) to be shipped as special form radioactive material in the Beneficial Uses Shipping System (BUSS) Cask. The capsules were originally approved as special form in 1975, but in 1988 the integrity of the capsules came into question. WHC developed the Pre-shipment Acceptance Test Criteria for capsules to meet in order to be shipped as special form material. The Department of Energy approved the criteria and directed WHC to ship the capsules at IOTECH and ARECO meeting this criteria to WHC as special form material

  4. Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water

    Energy Technology Data Exchange (ETDEWEB)

    Nussinovitch, A., E-mail: amos.nussi@mail.huji.ac.il; Dagan, O.

    2015-12-15

    Highlights: • Novel liquid-core capsules with a non-crosslinked alginate core were produced. • Capsules demonstrated highest efficiency adsorption of ∼300 mg Pb{sup 2+}/g alginate. • Regeneration was carried out by suspending capsules in 1 M HNO{sub 3} for 24 h. • Adsorption capacities of the capsules followed the order: Pb{sup 2+} > Cu{sup 2+} > Cd{sup 2+} > Ni{sup 2+}. - Abstract: Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan–alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb{sup 2+}/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb{sup +2}/g dry alginate vs. 267 mg Pb{sup +2}/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules’ ability to adsorb other heavy-metal cations – copper (Cu{sup 2+}), cadmium (Cd{sup 2+}) and nickel (Ni{sup 2+}) – was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation’s affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1 M nitric acid suspension for 24 h. Capsules could undergo three regeneration cycles before becoming damaged.

  5. Clinical effect of Resina Draconis capsules on primary dysmenorrhoea

    African Journals Online (AJOL)

    Clinical effect of Resina Draconis capsules on primary dysmenorrhoea. Li Sun, Jia Wang. Abstract. Purpose: To examine the effectiveness of Resina Draconis capsules in the treatment of primary dysmenorrhoea. Methods: In total, 324 patients with primary dysmenorrhoea were randomly allocated to three groups based on ...

  6. Design Improvements of a Fuel Capsule for Re-irradiation Tests

    International Nuclear Information System (INIS)

    Kang, Young-Hwan; Choi, Myung-Hwan; Kim, Jong Kiun; Youm, Ki Un; Yoon, Ki Byeong; Kim, Bong Goo

    2006-01-01

    The development of an advanced reactor system such as the next generation nuclear plant and other generation IV systems require new fuels, claddings, and structural materials. To characterize the performance of these new materials, it is necessary for us to have leading-edge technology to satisfy the specific test requirements of the recent R and D activities such as the high-fluence- and high burnup- related tests. Thus, new capsule assembling technology and re-instrumentation technology has been developed to meet the demands for the high burnup test at HANARO since 2003. In 2003, a mockup of the capsule assembly machine was designed and fabricated. The performance test which started in 2004 was undertaken to determine and present the main performance characteristics of the capsule assembly machine (CAM) including the special tools. In 2005, a series of analyses using a finite element analysis program, ANSYS and full scale tests in air were performed to improve the design of the capsule's components for an effective utilization of the CAM. The handling tools were fully qualified through the performance tests in 2006. KAERI is now reviewing the water flow area in the top region of a fuel capsule main body for re-irradiation tests and optimizing the design of the central region area of a capsule to be joined with special bolts

  7. Adhesive capsulitis: review of imaging and treatment

    International Nuclear Information System (INIS)

    Harris, Guy; Bou-Haider, Pascal; Harris, Craig

    2013-01-01

    Adhesive capsulitis is one of the most common conditions affecting the shoulder; however, early clinical diagnosis can be challenging. Treatment is most effective when commenced prior to the onset of capsular thickening and contracture; consequently, the role of imaging is increasing. The aim of this review is to demonstrate the typical imaging appearances of adhesive capsulitis and to examine some of the evidence regarding each of these imaging modalities. An evaluation of the various management options available to the clinician is also presented.

  8. Validity, Reliability, and Inertia of Four Different Temperature Capsule Systems.

    Science.gov (United States)

    Bongers, Coen C W G; Daanen, Hein A M; Bogerd, Cornelis P; Hopman, Maria T E; Eijsvogels, Thijs M H

    2018-01-01

    Telemetric temperature capsule systems are wireless, relatively noninvasive, and easily applicable in field conditions and have therefore great advantages for monitoring core body temperature. However, the accuracy and responsiveness of available capsule systems have not been compared previously. Therefore, the aim of this study was to examine the validity, reliability, and inertia characteristics of four ingestible temperature capsule systems (i.e., CorTemp, e-Celsius, myTemp, and VitalSense). Ten temperature capsules were examined for each system in a temperature-controlled water bath during three trials. The water bath temperature gradually increased from 33°C to 44°C in trials 1 and 2 to assess the validity and reliability, and from 36°C to 42°C in trial 3 to assess the inertia characteristics of the temperature capsules. A systematic difference between capsule and water bath temperature was found for CorTemp (0.077°C ± 0.040°C), e-Celsius (-0.081°C ± 0.055°C), myTemp (-0.003°C ± 0.006°C), and VitalSense (-0.017°C ± 0.023°C; P 0.05). Comparable inertia characteristics were found for CorTemp (25 ± 4 s), e-Celsius (21 ± 13 s), and myTemp (19 ± 2 s), whereas the VitalSense system responded more slowly (39 ± 6 s) to changes in water bath temperature (P inertia were observed between capsule systems, an excellent validity, test-retest reliability, and inertia was found for each system between 36°C and 44°C after removal of outliers.

  9. Strontium and cesium radionuclide leak detection alternatives in a capsule storage pool

    International Nuclear Information System (INIS)

    Larson, D.E.; Crawford, T.W.; Joyce, S.M.

    1981-08-01

    A study was performed to assess radionuclide leak-detection systems for use in locating a capsule leaking strontium-90 or cesium-137 into a water-filled pool. Each storage pool contains about 35,000 L of water and up to 715 capsules, each of which contains up to 150 kCi strontium-90 or 80 kCi cesium-137. Potential systems assessed included instrumental chemical analyses, radionuclide detection, visual examination, and other nondestructive nuclear-fuel examination techniques. Factors considered in the assessment include: cost, simplicity of maintenance and operation, technology availability, reliability, remote operation, sensitivity, and ability to locate an individual leaking capsule in its storage location. The study concluded that an adaption of the spent nuclear-fuel examination technique of wet sipping be considered for adaption. In the suggested approoch, samples would be taken continuously from pool water adjacent to the capsule(s) being examined for remote radiation detection. In-place capsule isolation and subsequent water sampling would confirm that a capsule was leaking radionuclides. Additional studies are needed before implementing this option. Two other techniques that show promise are ultrasonic testing and eddy-current testing

  10. State diagram for adhesion dynamics of deformable capsules under shear flow.

    Science.gov (United States)

    Luo, Zheng Yuan; Bai, Bo Feng

    2016-08-17

    Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca state no longer appears, since capsules exhibit large deviation from the spherical shape.

  11. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y H; Cho, M S [and others

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  12. Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

    Science.gov (United States)

    Batur, Muhammed; Seven, Erbil; Tekin, Serek; Yasar, Tekin

    2017-11-01

    The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX). This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded. Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81). With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

  13. Characterisation of two AGATA asymmetric high purity germanium capsules

    International Nuclear Information System (INIS)

    Colosimo, S.J.; Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S.; Lazarus, I.H.; Nolan, P.J.; Simpson, J.; Unsworth, C.

    2015-01-01

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array

  14. Characterisation of two AGATA asymmetric high purity germanium capsules

    Energy Technology Data Exchange (ETDEWEB)

    Colosimo, S.J., E-mail: sjc@ns.ph.liv.ac.uk [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Moon, S.; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Harkness-Brennan, L.; Judson, D.S. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Nolan, P.J. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury, Daresbury, Warrington WA4 4AD (United Kingdom); Unsworth, C. [Department of Physics, Oliver Lodge Laboratory, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2015-02-11

    The AGATA spectrometer is an array of highly segmented high purity germanium detectors. The spectrometer uses pulse shape analysis in order to track Compton scattered γ-rays to increase the efficiency of nuclear spectroscopy studies. The characterisation of two high purity germanium detector capsules for AGATA of the same A-type has been performed at the University of Liverpool. This work will examine the uniformity of performance of the two capsules, including a comparison of the resolution and efficiency as well as a study of charge collection. The performance of the capsules shows good agreement, which is essential for the efficient operation of the γ-ray tracking array.

  15. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  16. Capsule Performance Optimization in the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2009-10-13

    A capsule performance optimization campaign will be conducted at the National Ignition Facility to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  17. Capsule performance optimization in the national ignition campaign

    International Nuclear Information System (INIS)

    Landen, O L; MacGowan, B J; Haan, S W; Edwards, J

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  18. Capsule performance optimization in the national ignition campaign

    Science.gov (United States)

    Landen, O. L.; MacGowan, B. J.; Haan, S. W.; Edwards, J.

    2010-08-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [1] to substantially increase the probability of ignition. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the Omega facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  19. Integrity Assessment of HANARO Irradiation Capsule for Long-Term Irradiation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Kee Nam; Cho, Man Soon; Yang, Sung Woo; Shin, Yoon Taek; Park, Seng Jae; Yang, Tae Ho; Jun, Byung Hyuk; Kim, Myong Seop [KAERI, Daejeon (Korea, Republic of); Hong, Sang Hyun [Chungnam University, Daejeon (Korea, Republic of)

    2016-05-15

    The capsule technology was basically developed for irradiation testing under a commercial reactor operation environment. Most irradiation testing using capsules has been performed at around 300 .deg. C within four reactor operation cycles (about 100 days equivalent to 1.5 dpa (displacement for atom)) at HANARO. Based on the accumulated experience as well as the sophisticated requirements of users, HANARO has recently been required to support national R and D projects requiring much higher neutron fluence. To scope the user requirements for higher neutron irradiation fluence, several efforts using an instrumented capsule have been applied at HANARO. In this paper, the applied stresses on the capsule are estimated because the capsule was suspected to be susceptible to fatigue failure during irradiation testing. In addition, the on-going design improvements of the irradiation capsule for higher neutron irradiation fluence at HANARO are described. The applied stresses on the rod tip were analyzed using the ANSYS program. The applied stresses on the rod tip can be classified into stresses by the designed bottom spring, by the upward flowing coolant, by the capsule vibration, and by the welding residual stress. The maximal stresses due to the first three factors were estimated as 5.4 MPa, 132.9 MPa, and 161 MPa, respectively. These stresses do not exceed the known fatigue strength of stainless steels (∼300 MPa). Residual stress by welding is another possible stress and it is known to occur at up to about 300 MPa.

  20. WESF cesium capsule behavior at high temperature or during thermal cycling

    International Nuclear Information System (INIS)

    Tingey, G.L.; Gray, W.J.; Shippell, R.J.; Katayama, Y.B.

    1985-06-01

    Double-walled stainless steel (SS) capsules prepared for storage of radioactive 137 Cs from defense waste are now being considered for use as sources for commercial irradiation. Cesium was recovered at B-plant from the high-level radioactive waste generated during processing of defense nuclear fuel. It was then purified, converted to the chloride form, and encapsulated at the Hanford Waste Encapsulation and Storage Facility (WESF). The molten cesium chloride salt was encapsulated by pouring it into the inner of two concentric SS cylinders. Each cylinder was fitted with a SS end cap that was welded in place by inert gas-tungsten arc welding. The capsule configuration and dimensions are shown in Figure 1. In a recent review of the safety of these capsules, Tingey, Wheelwright, and Lytle (1984) indicated that experimental studies were continuing to produce long-term corrosion data, to reaffirm capsule integrity during a 90-min fire where capsule temperatures reached 800 0 C, to monitor mechanical properties as a function of time, and to assess the effects of thermal cycling due to periodic transfer of the capsules from a water storage pool to the air environment of an irradiator facility. This report covers results from tests that simulated the effects of the 90-min fire and from thermal cycling actual WESF cesium capsules for 3845 cycles over a period of six months. 11 refs., 39 figs., 9 tabs

  1. Sub-Scale Re-entry Capsule Drop via High Altitude Balloons

    Data.gov (United States)

    National Aeronautics and Space Administration — The project objective is to develop and test a sub-scale version of the Maraia Entry Capsule on a high altitude balloon. The capsule is released at 100,000 ft. The...

  2. Development of glia and blood vessels in the internal capsule of rats.

    Science.gov (United States)

    Earle, K L; Mitrofanis, J

    1998-02-01

    We have explored two aspects of internal capsule development that have not been described previously, namely, the development of glia and of blood vessels. To these ends, we used antibodies to glial fibrillary acidic protein (GFAP) and to vimentin (to identify astrocytes and to radial glia) and Griffonia simplicifolia (lectin; to identify microglia and blood vessels). Further, we made intracardiac injections of Evans Blue to examine the permeability of this dye in the vessels of the internal capsule during neonatal development. Our results show that large numbers of radial glia, astrocytes and microglia are not labelled with these markers in the white matter of the internal capsule until about birth; very few are labelled earlier, during the critical stages of corticofugal and corticopetal axonal ingrowth (E15-E20). The large glial labelling in the internal capsule at birth is accompanied by a dense vascular innervation of the capsule; as with the glia, very few labelled patent vessels are seen earlier. After intracardiac injections of Evans Blue, we find that the blood vessels of the internal capsule are not particularly permeable to Evans Blue. At each age examined (P0, P5, P15), blood vessels are outlined very clearly and there is no diffuse haze of fluorescence within the extracellular space, which is indicative of a leaky vessel. There are three striking differences between the glial environment of the internal capsule and that of the adjacent thalamus. First, the internal capsule is never rich with radial glial fibres (vimentin- and GFAP-immunoreactive) during development (except at P0), whereas the thalamus has many radial fibres from very early development (E15-E17). Second, astrocytes (vimentin- and GFAP-immunoreactive) first become apparent in the internal capsule (E20-P0) well before they do in the thalamus (P15). Third, the internal capsule houses a large transient population of amoeboid microglia (P0-P22), whereas the thalamus does not; only ramified

  3. A legged anchoring mechanism for capsule endoscopes using micropatterned adhesives.

    Science.gov (United States)

    Glass, Paul; Cheung, Eugene; Sitti, Metin

    2008-12-01

    This paper presents a new concept for an anchoring mechanism to enhance existing capsule endoscopes. The mechanism consists of three actuated legs with compliant feet lined with micropillar adhesives to be pressed into the intestine wall to anchor the device at a fixed location. These adhesive systems are inspired by gecko and beetle foot hairs. Single-leg and full capsule mathematical models of the forces generated by the legs are analyzed to understand capsule performance. Empirical friction models for the interaction of the adhesives with an intestinal substrate were experimentally determined in vitro using dry and oil-coated elastomer micropillar arrays with 140 microm pillar diameter, 105 microm spacing between pillars, and an aspect ratio of 1:1 on fresh porcine small intestine specimens. Capsule prototypes were also tested in a simulated intestine environment and compared with predicted peristaltic loads to assess the viability of the proposed design. The experimental results showed that a deployed 10 gr capsule robot can withstand axial peristaltic loads and anchor reliably when actuation forces are greater than 0.27 N using dry micropillars. Required actuation forces may be reduced significantly by using micropillars coated with a thin silicone oil layer.

  4. A disposable and multifunctional capsule for easy operation of microfluidic elastomer systems

    International Nuclear Information System (INIS)

    Thorslund, Sara; Läräng, Thomas; Kreuger, Johan; Nguyen, Hugo; Barkefors, Irmeli

    2011-01-01

    The global lab-on-chip and microfluidic markets for cell-based assays have been predicted to grow considerably, as novel microfluidic systems enable cell biologists to perform in vitro experiments at an unprecedented level of experimental control. Nevertheless, microfluidic assays must, in order to compete with conventional assays, be made available at easily affordable costs, and in addition be made simple to operate for users having no previous experience with microfluidics. We have to this end developed a multifunctional microfluidic capsule that can be mass-produced at low cost in thermoplastic material. The capsule enables straightforward operation of elastomer inserts of optional design, here exemplified with insert designs for molecular gradient formation in microfluidic cell culture systems. The integrated macro–micro interface of the capsule ensures reliable connection of the elastomer fluidic structures to an external perfusion system. A separate compartment in the capsule filled with superabsorbent material is used for internal waste absorption. The capsule assembly process is made easy by integrated snap-fits, and samples within the closed capsule can be analyzed using both inverted and upright microscopes. Taken together, the capsule concept presented here could help accelerate the use of microfluidic-based biological assays in the life science sector. (technical note)

  5. Effect of preparation conditions on properties and permeability of chitosan-sodium hexametaphosphate capsules.

    Science.gov (United States)

    Angelova, N; Hunkeler, D

    2001-01-01

    Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.

  6. SATCAP: a program for thermal-hydraulic design of saturated temperature capsule

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Niimi, Motoji; Someya, Hiroyuki; Kobayashi, Toshiki.

    1988-02-01

    For material irradiation tests at JMTR, user's technical requirements are gradually becoming more rigid, permitting only a small temperature deviation from the desired during irradiation of test materials. As specimen temperature control equipment, several conception were proposed and some of them were translated into actual machines with the capsule having electrical seath heaters in it. This system is highly reliable unless the integrity of the heaters is threatened. However, in a test with the object of achieving a high exposure of specimen to neutrons, the break of a heater or deterioration of a heater caused by irradiation lowers the reliability of the system. To cope with this drawback, as a part of the irradiation technique improvement program, ''Satulated Temperature Capsule'' has been developing. This type capsule, in which the water suplied is boiled, bases on the conception of keeping the coolant at the saturated temperature facilitates the temperature control. Though there are various types of capsules employed at JMTR, the experience of the capsule into which the coolant is injected lacks. In designing, thermal performances have to fully understood. Therefore, a program was compiled to evaluate the thermal behavior in the capsule. The present report describes the calculation procedure and guides of input and output for the program. (author)

  7. Capsule Development and Utilization for Material Irradiation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Goo; Kang, Y. H.; Cho, M. S. (and others)

    2007-06-15

    The essential technology for an irradiation test of materials and nuclear fuel has been successively developed and utilized to meet the user's requirements in Phase I(July 21, 1997 to March 31, 2000). It enables irradiation tests to be performed for a non-fissile material under a temperature control(300{+-}10 .deg. C) in a He gas environment, and most of the irradiation tests for the internal and external users are able to be conducted effectively. The basic technology was established to irradiate a nuclear fuel, and a creep capsule was also developed to measure the creep property of a material during an irradiation test in HANARO in Phase II(April 1, 2000 to March 31, 2003). The development of a specific purpose capsule, essential technology for a re-irradiation of a nuclear fuel, advanced technology for an irradiation of materials and a nuclear fuel were performed in Phase III(April 1, 2003 to February 28, 2007). Therefore, the technology for an irradiation test was established to support the irradiation of materials and a nuclear fuel which is required for the National Nuclear R and D Programs. In addition, an improvement of the existing capsule design and fabrication technology, and the development of an instrumented capsule for a nuclear fuel and a specific purpose will be able to satisfy the user's requirements. In order to support the irradiation test of materials and a nuclear fuel for developing the next generation nuclear system, it is also necessary to continuously improve the design and fabrication technology of the existing capsule and the irradiation technology.

  8. Remote-welding technique for assembling in-pile IASCC capsule in hot cell

    International Nuclear Information System (INIS)

    Kawamata, Kazuo; Ishii, Toshimitsu; Kanazawa, Yoshiharu; Iwamatsu, Shigemi; Ohmi, Masao; Shimizu, Michio; Matsui, Yoshinori; Saito, Jun-ichi; Ugachi, Hirokazu; Kaji, Yoshiyuki; Tsukada, Takashi

    2006-01-01

    In order to investigate behavior of the irradiation assisted stress corrosion cracking (IASCC) caused by the simultaneous effects of neutron irradiation and high temperature water environment in such a light water reactor (LWR), it is necessary to perform crack growth tests in an in-pile IASCC capsule irradiated in the Japan Materials Testing Reactor (JMTR). The development of the remote-welding technique is essential for remotely assembling the in-pile IASCC capsule installing the pre-irradiated CT specimens. This report describes a new remote-welding machine developed for assembling the in-pile IASCC capsule. The remote-welding technique that the capsule tube is rotated light under the fixed torch was applied to the machine for the welding of thick and large-diameter tubes. The assembly work of four in-pile IASCC capsules having pre-irradiated CT specimens in the hot cell was succeeded for performing the crack growth test under the neutron irradiation in JMTR. The irradiation test of two capsules has been already finished in JMTR without problems. (author)

  9. Development of target capsules for muon catalyzed fusion experiments

    International Nuclear Information System (INIS)

    Watts, K.D.; Jones, S.E.; Caffrey, A.J.

    1983-01-01

    A series of Muon Catalyzed Fusion experiments has been conducted at the Los Alamos Meson Physics Facility to determine how many fusion reactions one muon would catalyze under various temperature, pressure, contamination, and tritium concentration conditions. Target capsules to contain deuterium and tritium at elevated temperatures and pressures were engineered for a maximum temperature of 540 K (512 0 F) and a maximum pressure of 103 MPa (15,000 psig). Experimental data collected with these capsules indicated that the number of fusion reactions per muon continued to increase with temperature up to the 540-K design limit. Theory had indicated that the reaction rate should peak at approximately 540 K, but this was not confirmed during the experiments. A second generation of capsules which have a maximum design temperature of 800 K (980 0 F) and a maximum design pressure of 103 MPa (15,000 psig) has now been engineered. These new capsules will be used to further study the muon catalysis rate versus deuterium-tritium mixture temperature

  10. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment.

    Directory of Open Access Journals (Sweden)

    Thanh Nho Do

    Full Text Available Intra-gastric balloons (IGB have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient's stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient's stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight.

  11. Temporary presence of myofibroblasts in human elbow capsule after trauma

    NARCIS (Netherlands)

    Doornberg, Job N.; Bosse, Tjalling; Cohen, Mark S.; Jupiter, Jesse B.; Ring, David; Kloen, Peter

    2014-01-01

    Elbow stiffness is a common complication after elbow trauma. The elbow capsule is often thickened, fibrotic, and contracted at the time of surgical release. The limited studies available suggest that the capsule is contracted because of fibroblast-to-myofibroblast differentiation. We hypothesize

  12. Non-small-bowel abnormalities identified during small bowel capsule endoscopy

    NARCIS (Netherlands)

    Hoedemakers, Reinier; Westerhof, Jessie; Weersma, Rinse K.; Koornstra, Jan J.

    2014-01-01

    AIM: To investigate the incidence of non-small-bowel abnormalities in patients referred for small bowel capsule endoscopy, this single center study was performed. METHODS: Small bowel capsule endoscopy is an accepted technique to investigate obscure gastrointestinal bleeding. This is defined as

  13. Transport of solid commodities via freight pipeline: freight pipeline technology. Volume II. First year final report. [Slurry, pneumatic, pneumo-capsule, and hydro-capsule

    Energy Technology Data Exchange (ETDEWEB)

    Zandi, I.; Gimm, K.K.

    1976-07-01

    In order to determine the feasibility of pipeline as an intercity freight transportation mode, it was necessary to examine its technological feasibility and reliability. This report describes the technology of the major generic freight pipelines in terms of both historical and current trends and operations. Additionally, it presents a state-of-the-art review of calculating energy requirements of various generic freight pipelines. It was concluded that slurry and pneumatic pipelines are technologically feasible and reliable. There are many commercial installations of both types operating around the world. Based on European experience with pneumo-capsule pipelines for mail delivery and Russian gravel- and sand-transport installations, it appears that a pneumo-capsule pipeline is a technologically feasible and operationally reliable mode for transport of solids. Since no commercial pneumo-capsule pipeline installations yet exist in the U.S., it seems desirable that a service demonstration of the advantages and feasibility of this mode of transport be undertaken to attract the shippers' confidence. Hydro-capsule pipelines are technologically feasible, but its reliability within a commercial environment remains to be tested.

  14. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Science.gov (United States)

    Rendueles, Olaya; Garcia-Garcerà, Marc; Néron, Bertrand; Touchon, Marie; Rocha, Eduardo P C

    2017-07-01

    Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by-product of environmental

  15. Abundance and co-occurrence of extracellular capsules increase environmental breadth: Implications for the emergence of pathogens.

    Directory of Open Access Journals (Sweden)

    Olaya Rendueles

    2017-07-01

    Full Text Available Extracellular capsules constitute the outermost layer of many bacteria, are major virulence factors, and affect antimicrobial therapies. They have been used as epidemiological markers and recently became vaccination targets. Despite the efforts to biochemically serotype capsules in a few model pathogens, little is known of their taxonomic and environmental distribution. We developed, validated, and made available a computational tool, CapsuleFinder, to identify capsules in genomes. The analysis of over 2500 prokaryotic genomes, accessible in a database, revealed that ca. 50% of them-including Archaea-encode a capsule. The Wzx/Wzy-dependent capsular group was by far the most abundant. Surprisingly, a fifth of the genomes encode more than one capsule system-often from different groups-and their non-random co-occurrence suggests the existence of negative and positive epistatic interactions. To understand the role of multiple capsules, we queried more than 6700 metagenomes for the presence of species encoding capsules and showed that their distribution varied between environmental categories and, within the human microbiome, between body locations. Species encoding capsules, and especially those encoding multiple capsules, had larger environmental breadths than the other species. Accordingly, capsules were more frequent in environmental bacteria than in pathogens and, within the latter, they were more frequent among facultative pathogens. Nevertheless, capsules were frequent in clinical samples, and were usually associated with fast-growing bacteria with high infectious doses. Our results suggest that capsules increase the environmental range of bacteria and make them more resilient to environmental perturbations. Capsules might allow opportunistic pathogens to profit from empty ecological niches or environmental perturbations, such as those resulting from antibiotic therapy, to colonize the host. Capsule-associated virulence might thus be a by

  16. Formulation, process development and evaluation of artemether and lumefantrine soft gelatin capsule

    Directory of Open Access Journals (Sweden)

    A Patel

    2012-01-01

    Full Text Available Artemether and Lumefantrine capsules are indicated for the treatment of P. falciparum malaria cases resistant to both chloroquine and sulphadoxine, pyrimethamine combination. Both artemether and lumefantrine act as blood schizontocides. Artemether is a sesquiterpene lactone derived from artemisinin. Artemisinin is a compound derived from the sweet wormwood plant and has been used for centuries in traditional Chinese medicine to treat fever. Lumefantrine is a synthetic aryl-amino alcohol antimalarial (quinine, mefloquine and halofantrine are members of the same group. Artemether is absorbed fairly rapidly with peak plasma concentrations reached about 2 hours after dosing. Absorption of lumefantrine, a highly lipophilic compound, starts after a lag period of up to 2 hours, with peak plasma concentration about 6-8 hours after dosing. In order to overcome this problem, we have observed that when the drug is given in the soft gelatin dosage form, the bioavailability of the drug is increased. Thus, increasing the absorption of the drug and peak plasma concentration is reached earlier then the conventional dosage form.

  17. SLiM : an improved soil moisture balance method to simulate runoff and potential groundwater recharge processes using spatio-temporal weather and catchment characteristics

    OpenAIRE

    Wang, Lei; Barkwith, Andrew; Jackson, Christopher; Ellis, Michael

    2012-01-01

    The numerical modelling of runoff and groundwater recharge plays an important role in water resource management. The methodologies developed for these simulations should represent the key physical processes, and be applicable in a wide variety of climates for routine simulations using readily available field information. This paper describes the development of a Soil and Landuse based rainfall-runoff and recharge Model (SLiM) based on Rushton’s method – a single soil layer groundwater recharg...

  18. NMR relaxation dispersion of Miglyol molecules confined inside polymeric micro-capsules.

    Science.gov (United States)

    Nechifor, Ruben; Ardelean, Ioan; Mattea, Carlos; Stapf, Siegfried; Bogdan, Mircea

    2011-11-01

    Frequency dependent NMR relaxation studies have been carried out on Miglyol molecules confined inside core shell polymeric capsules to obtain a correlation between capsule dimension and the measurable parameters. The polymeric capsules were prepared using an interfacial polymerization technique for three different concentrations of Miglyol. It was shown that the variation of Miglyol concentration influences the capsule dimension. Their average size was estimated using the pulsed field gradient diffusometry technique. The relaxation dispersion curves were obtained at room temperature by a combined use of a fast field cycling instrument and a high-field instrument. The frequency dependence of relaxation rate shows a transition from a diffusion-limited to a surface-limited relaxation regime. Copyright © 2011 John Wiley & Sons, Ltd.

  19. X-ray drive of beryllium capsule implosions at the National Ignition Facility

    International Nuclear Information System (INIS)

    Wilson, D C; Yi, S A; Simakov, A N; Kline, J L; Kyrala, G A; Olson, R E; Zylstra, A B; Dewald, E L; Tommasini, R; Ralph, J E; Strozzi, D J; Celliers, P M; Schneider, M B; MacPhee, A G; Callahan, D A; Hurricane, O A; Milovich, J L; Hinkel, D E; Rygg, J R; Rinderknecht, H G

    2016-01-01

    National Ignition Facility experiments with beryllium capsules have followed a path begun with “high-foot” plastic capsule implosions. Three shock timing keyhole targets, one symmetry capsule, a streaked backlit capsule, and a 2D backlit capsule were fielded before the DT layered shot. After backscatter subtraction, laser drive degradation is needed to match observed X-ray drives. VISAR measurements determined drive degradation for the picket, trough, and second pulse. Time dependence of the total Dante flux reflects degradation of the of the third laser pulse. The same drive degradation that matches Dante data for three beryllium shots matches Dante and bangtimes for plastic shots N130501 and N130812. In the picket of both Be and CH hohlraums, calculations over-estimate the x-ray flux > 1.8 keV by ∼100X, while calculating the total flux correctly. In beryllium calculations these X-rays cause an early expansion of the beryllium/fuel interface at ∼3 km/s. VISAR measurements gave only ∼0.3 km/s. The X-ray drive on the Be DT capsule was further degraded by an unplanned decrease of 9% in the total picket flux. This small change caused the fuel adiabat to rise from 1.8 to 2.3. The first NIF beryllium DT implosion achieved 29% of calculated yield, compared to CH capsules with 68% and 21%. (paper)

  20. Fabrication and operation of HFIR-MFE RB* spectrally tailored irradiation capsules

    International Nuclear Information System (INIS)

    Longest, A.W.; Pawel, J.E.; Heatherly, D.W.; Sitterson, R.G.; Wallace, R.L.

    1993-01-01

    Fabrication and operation of four HFIR-MFE RB * capsules (60, 200, 330, and 400 degrees C) to accommodate MFE specimens previously irradiated in spectrally tailored experiments in the ORR are proceeding satisfactorily. With the exception of the 60 degrees C capsule, where the test specimens were in direct contact with the reactor cooling water, specimen temperatures (monitored by 21 thermocouples) are controlled by varying the thermal conductance of a thin gap region between the specimen holder outer sleeve and containment tube. Irradiation of the 60 and 330 degrees C capsules, which started on July 17, 1990, was completed on November 14, 1992, after 24 cycles of irradiation to an incremental damage level of approximately 10.9 displacements per atom (dpa). Assembly of the follow-up 200 and 400 degrees C capsules was completed in November 1992, and their planned 20-cycle irradiation to approximately 9.1 incremental dpa was started on November 21, 1992. As of February 11, 1993, the 200 and 400 degrees C capsules had successfully completed three cycles of irradiation to approximately 1.4 incremental dpa

  1. Imaging of High-Z doped, Imploded Capsule Cores

    Science.gov (United States)

    Prisbrey, Shon T.; Edwards, M. John; Suter, Larry J.

    2006-10-01

    The ability to correctly ascertain the shape of imploded fusion capsules is critical to be able to achieve the spherical symmetry needed to maximize the energy yield of proposed fusion experiments for the National Ignition Facility. Implosion of the capsule creates a hot, dense core. The introduction of a high-Z dopant into the gas-filled core of the capsule increases the amount of bremsstrahlung radiation produced in the core and should make the imaging of the imploded core easier. Images of the imploded core can then be analyzed to ascertain the symmetry of the implosion. We calculate that the addition of Ne gas into a deuterium gas core will increase the amount of radiation emission while preserving the surrogacy of the radiation and hydrodynamics in the indirect drive NIF hohlraum in the proposed cryogenic hohlraums. The increased emission will more easily enable measurement of asymmetries and tuning of the implosion.

  2. Alternative hot spot formation techniques using liquid deuterium-tritium layer inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Olson, R. E.; Leeper, R. J.

    2013-01-01

    The baseline DT ice layer inertial confinement fusion (ICF) ignition capsule design requires a hot spot convergence ratio of ∼34 with a hot spot that is formed from DT mass originally residing in a very thin layer at the inner DT ice surface. In the present paper, we propose alternative ICF capsule designs in which the hot spot is formed mostly or entirely from mass originating within a spherical volume of DT vapor. Simulations of the implosion and hot spot formation in two DT liquid layer ICF capsule concepts—the DT wetted hydrocarbon (CH) foam concept and the “fast formed liquid” (FFL) concept—are described and compared to simulations of standard DT ice layer capsules. 1D simulations are used to compare the drive requirements, the optimal shock timing, the radial dependence of hot spot specific energy gain, and the hot spot convergence ratio in low vapor pressure (DT ice) and high vapor pressure (DT liquid) capsules. 2D simulations are used to compare the relative sensitivities to low-mode x-ray flux asymmetries in the DT ice and DT liquid capsules. It is found that the overall thermonuclear yields predicted for DT liquid layer capsules are less than yields predicted for DT ice layer capsules in simulations using comparable capsule size and absorbed energy. However, the wetted foam and FFL designs allow for flexibility in hot spot convergence ratio through the adjustment of the initial cryogenic capsule temperature and, hence, DT vapor density, with a potentially improved robustness to low-mode x-ray flux asymmetry

  3. SATCAP-B: a program for thermal-hydraulic design of 'Saturated Temperature Capsule'

    International Nuclear Information System (INIS)

    Harayama, Yasuo; Someya, Hiroyuki; Niimi, Motoji

    1989-11-01

    As an advanced irradiation technique, the JMTR (Japan Materials Testing Reactor) project is developing a 'Saturated Temperature Capsule' which water is injected in and boiled. When the water is kept at a constant pressure, the water temperature does not become higher than the saturated temperature. This type capsule is based on the conception of keeping the coolant to the saturated temperature and using the temperature control. In designing the capsule in which the inner coolant is injected, thermal performances have to be understood as exactly as possible. Then, a program (named SATCAP) was compiled to graps the thermal performance within the capsule. On the other hand, a 'Saturated Temperature Capsule' was made and irradiated in the JMTR core. It was indicated from supplied water temperatures recorded by thermo-couples attached in the capsule that heat transfer coefficients prefered models due to natural convection to models incorporated in the initial version of the program. Then, the program was revised by adding mainly heat transfer model based on natural convection. The present report describes the calculation procedure and guides of input and output for the revised program (SATCAP version-B). (author)

  4. Mitigate the tent-induced perturbation in ignition capsules by supersonic radiation propagation

    Science.gov (United States)

    Dai, Zhensheng; Gu, Jianfa; Zheng, Wudi

    2017-10-01

    In the inertial confinement fusion (ICF) scheme, to trap the alpha particle products of the D-T reaction, the capsules needs to be imploded and compressed with high symmetry In the laser indirect drive scheme, the capsules are held at the center of high-Z hohlraums by thin membranes (tents). However, the tents are recognized as one of the most important contributors to hot spot asymmetries, areal density perturbations and reduced performance. To improve the capsule implosion performance, various alternatives such as the micro-scale rods, a larger fill-tube and a low-density foam layer around the capsule have been presented. Our simulations show that the radiation propagates supersonically in the low-density foam layer and starts to ablate the capsule before the perturbations induced by the tents reach the ablating fronts. The tent induced perturbations are remarkably weakened when they are propagating in the blow-off plasma.

  5. A hydrogel capsule as gate dielectric in flexible organic field-effect transistors

    Energy Technology Data Exchange (ETDEWEB)

    Dumitru, L. M.; Manoli, K.; Magliulo, M.; Torsi, L., E-mail: luisa.torsi@uniba.it [Department of Chemistry, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Ligonzo, T. [Department of Physics, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Palazzo, G. [Department of Chemistry, University of Bari “Aldo Moro”, Via Orabona 4, Bari I-70126 (Italy); Center of Colloid and Surface Science—CSGI—Bari Unit, Via Orabona 4, Bari I-70126 (Italy)

    2015-01-01

    A jellified alginate based capsule serves as biocompatible and biodegradable electrolyte system to gate an organic field-effect transistor fabricated on a flexible substrate. Such a system allows operating thiophene based polymer transistors below 0.5 V through an electrical double layer formed across an ion-permeable polymeric electrolyte. Moreover, biological macro-molecules such as glucose-oxidase and streptavidin can enter into the gating capsules that serve also as delivery system. An enzymatic bio-reaction is shown to take place in the capsule and preliminary results on the measurement of the electronic responses promise for low-cost, low-power, flexible electronic bio-sensing applications using capsule-gated organic field-effect transistors.

  6. Thin film drainage between pre-inflated capsules or vesicles

    Science.gov (United States)

    Keh, Martin; Walter, Johann; Leal, Gary

    2013-11-01

    Capsules and vesicles are often used as vehicles to carry active ingredients or fragrance in drug delivery and consumer products and oftentimes in these applications the particles may be pre-inflated due to the existence of a small osmotic pressure difference between the interior and exterior fluid. We study the dynamics of thin film drainage between capsules and vesicles in flow as it is crucial to fusion and deposition of the particles and, therefore, the stability and effectiveness of the products. Simulations are conducted using a numerical model coupling the boundary integral method for the motion of the fluids and a finite element method for the membrane mechanics. For low capillary numbers, the drainage behavior of vesicles and capsules are approximately the same, and also similar to that of drops as the flow-independent and uniform tension due to pre-inflation dominates. The tension due to deformation caused by flow will become more important as the strength of the external flow (i.e. the capillary number) increases. In this case, the shapes of the thin film region are fundamentally different for capsules and vesicles, and the drainage behavior in both cases differs from a drop. Funded by P&G.

  7. A probabilistic method for determining the volume fraction of pre-embedded capsules in self-healing materials

    International Nuclear Information System (INIS)

    Lv, Zhong; Chen, Huisu

    2014-01-01

    Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance. (paper)

  8. Isolation and identification of a sibutramine analogue adulterated in slimming dietary supplements.

    Science.gov (United States)

    Kim, Ji Won; Kweon, Soon Jae; Park, Seon Kyung; Kim, Jung Yeon; Lee, Ji Hyun; Han, Kyoung Moon; Cho, Sooyeul; Kim, Jinho; Han, Soon Young; Kim, Hyoung Ja; Kim, Woo Seong

    2013-01-01

    A suspected sibutramine analogue was detected in a slimming functional food by an ultra performance liquid chromatography-electrospray ionisation-time of flight mass spectrometry (UPLC-ESI-TOF/MS) method. The ultraviolet (UV) spectrum of this suspected compound showed close similarity to that of sibutramine. The sample was extracted with 70% MeOH and isolated by semi-preparative column chromatography. The structure of this compound was identified by spectroscopic analyses (nuclear magnetic resonance [NMR] technique, mass and tandem mass etc.). The structure of the unknown compound was demonstrated to be [(±)-dimethyl-1-[1-(3,4-dichlorophenyl)cyclobutyl]-N,N,3-trimethylbutan-1-amine (molecular formula C17H25NCl2) and named as chloro-sibutramine. Compared with sibutramine, it has one more chlorine atom than the 3-cholorophenyl group so was switched to 3,4-dichlorophenyl. Until now, chloro-sibutramine was isolated for the first time from the undeclared ingredient included in dietary supplements. Although the safety of chloro-sibutramine is unknown, there is a potential health risk to consumers because of a similar skeleton to sibutramine. For public health, this sibutramine analogue has been included in the inspection list of illegal adulterants in Korea.

  9. Polysaccharide capsule-mediated resistance to opsonophagocytosis in Klebsiella pneumoniae.

    OpenAIRE

    Domenico, P; Salo, R J; Cross, A S; Cunha, B A

    1994-01-01

    The polysaccharide capsule of Klebsiella pneumoniae is an important virulence factor that confers resistance to phagocytosis. The treatment of encapsulated bacteria with salicylate to inhibit capsule expression was found to enhance the phagocytosis of encapsulated bacteria by human neutrophils only in the presence of cell surface-specific antibodies. Both type-specific rabbit antisera and anticapsular human hyperimmune globulin were employed as opsonins. Salicylate significantly enhanced phag...

  10. Evaluation of hard gelatin capsules and hydroxypropyl methylcellulose containing ampicillin

    Directory of Open Access Journals (Sweden)

    Graziella Gonçalves Weigert

    2012-01-01

    Full Text Available This study aims to develop and evaluate formulations containing ampicillin in capsules of gelatin and hydroxypropyl methylcellulose (HPMC. Two formulations (A and B were developed. The final product quality was evaluated by testing for quality control and the results were in agreement with the Brazilian Pharmacopoeia. The formulations with HPMC capsules showed lower percentages of drug dissolved (99.67%, HPMC-A and 87.70%, HPMC-B than the gelatin (100.18%, GEL-A and 101.16% GEL-B. Because of the delay of the ampicillin release observed in the dissolution profiles, it becomes necessary to evaluate the drugs that can be conditioned in the HPMC capsules.

  11. Prevalence and risk factors of adhesive capsulitis of the shoulder after breast cancer treatment.

    Science.gov (United States)

    Yang, Seoyon; Park, Dae Hwan; Ahn, Sei Hyun; Kim, Jisun; Lee, Jong Won; Han, Jun Young; Kim, Dong Kyu; Jeon, Jae Yong; Choi, Kyoung Hyo; Kim, Won

    2017-04-01

    The present study investigated the prevalence and risk factors of adhesive capsulitis of the shoulder in breast cancer patients between 13 and 18 months after surgery. This study included 271 women who underwent surgery for breast cancer with a postoperative period of 13-18 months. Current adhesive capsulitis was defined as restriction of external rotation and one or more additional directional restrictions with history of shoulder pain. Cumulative adhesive capsulitis was defined as current adhesive capsulitis or a previous history of adhesive capsulitis after breast cancer surgery. Multivariate logistic regression analysis was performed to examine associations between current or cumulative adhesive capsulitis and potential risk factors. Among the 271 study patients, 28 (10.3%) and 21 (7.7%) had cumulative or current adhesive capsulitis, respectively. The incidences of cumulative and current adhesive capsulitis were higher in those aged 50-59 years (odds ratio [OR], 9.912; 95% confidence interval [CI], 1.790-54.880; and OR, 12.395; 95% CI, 1.187-129.444, respectively) and those who underwent mastectomy (OR, 6.805; 95% CI, 1.800-25.733; and OR, 9.645; 95% CI, 2.075-44.829, respectively) or mastectomy with reconstruction (OR, 13.122; 95% CI, 2.488-69.218; and OR, 20.075; 95% CI, 2.873-140.261, respectively). Adhesive capsulitis of the shoulder is a common problem after breast cancer treatment. An age of 50-59 years and mastectomy are major risk factors for adhesive capsulitis, and breast reconstruction additionally increases the risk. Patients with these risk factors require greater attention for early diagnosis and proper treatment.

  12. Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure

    Science.gov (United States)

    Pan, C.; Huang, S.; Chang, Y.; Wen, J.

    2013-12-01

    The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.

  13. Generic Delivery of Payload of Nanoparticles Intracellularly via Hybrid Polymer Capsules for Bioimaging Applications

    Science.gov (United States)

    Sami, Haider; Maparu, Auhin K.; Kumar, Ashok; Sivakumar, Sri

    2012-01-01

    Towards the goal of development of a generic nanomaterial delivery system and delivery of the ‘as prepared’ nanoparticles without ‘further surface modification’ in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM) capsules has been reported, where polystyrene sulfonate (PSS)/polyallylamine hydrochloride (PAH) polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles) in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells), without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb3+ was observed after internalization of LaF3:Tb3+(5%) nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery) without the need of individual cargo design/modification. PMID:22649489

  14. Generic delivery of payload of nanoparticles intracellularly via hybrid polymer capsules for bioimaging applications.

    Directory of Open Access Journals (Sweden)

    Haider Sami

    Full Text Available Towards the goal of development of a generic nanomaterial delivery system and delivery of the 'as prepared' nanoparticles without 'further surface modification' in a generic way, we have fabricated a hybrid polymer capsule as a delivery vehicle in which nanoparticles are loaded within their cavity. To this end, a generic approach to prepare nanomaterials-loaded polyelectrolyte multilayered (PEM capsules has been reported, where polystyrene sulfonate (PSS/polyallylamine hydrochloride (PAH polymer capsules were employed as nano/microreactors to synthesize variety of nanomaterials (metal nanoparticles; lanthanide doped inorganic nanoparticles; gadolinium based nanoparticles, cadmium based nanoparticles; different shapes of nanoparticles; co-loading of two types of nanoparticles in their hollow cavity. These nanoparticles-loaded capsules were employed to demonstrate generic delivery of payload of nanoparticles intracellularly (HeLa cells, without the need of individual nanoparticle surface modification. Validation of intracellular internalization of nanoparticles-loaded capsules by HeLa cells was ascertained by confocal laser scanning microscopy. The green emission from Tb(3+ was observed after internalization of LaF(3:Tb(3+(5% nanoparticles-loaded capsules by HeLa cells, which suggests that nanoparticles in hybrid capsules retain their functionality within the cells. In vitro cytotoxicity studies of these nanoparticles-loaded capsules showed less/no cytotoxicity in comparison to blank capsules or untreated cells, thus offering a way of evading direct contact of nanoparticles with cells because of the presence of biocompatible polymeric shell of capsules. The proposed hybrid delivery system can be potentially developed to avoid a series of biological barriers and deliver multiple cargoes (both simultaneous and individual delivery without the need of individual cargo design/modification.

  15. Influence of different excipients on the properties of hard gelatin capsules with metamizole sodium

    Directory of Open Access Journals (Sweden)

    Rogowska Magdalena

    2016-09-01

    Full Text Available Metamizole is an effective non-opioid analgesic drug used in the treatment of acute and chronic pain. Due to induced potentially life-threatening blood disorders, metamizole was withdrawn from market in many parts of the world, however, it is one of the most popular analgesics in Poland that is available as an over the counter drug. Patients tend to prefer capsules over tablets, as they are easier to swallow and taste better. The powder-filled capsules also have greater bioavailability and require less excipients, as compared to tablets. Polymic excipients are mainly used in capsule filling, and have influence upon the physico-chemical properties of the hard gelatin capsules and the powder formulation. The aim of the study was to determine whether various combinations of polymers impact the disintegration time and pharmaceutical availability of hard gelatin capsules with metamizole sodium. The results of our work demonstrated that the 80% of all active substance was released in all tested formulations within 15 minutes. Herein, the capsule containing lactose monohydrate had the longest release (4% after 2 min., while capsules containing mannitol had the fastest release (81.2% after 2 min.. Moreover, the addition of HPMC to capsules with lactose brought about a slight increase in the metamizole release rate, while the addition of PVP 30 to capsules with microcrystalline cellulose slightly accelerated release. This data suggests that the use of different polymers in capsules formulation brings about changes in the physical properties of powders and modifies the release profile of metamizole. In our study, the most preferred formulation was one containing microcrystalline cellulose (good powder properties and fairly fast release.

  16. U-turn type continuous irradiation method and device for radiation-irradiated capsule

    International Nuclear Information System (INIS)

    Kikuchi, Takayuki.

    1997-01-01

    A capsule to be irradiated is moved while being rotated in one of conveying shafts disposed in a reactor to conduct irradiation treatment. Then, the irradiated capsule is made U-turn in the reactor, inserted to the other conveying shaft and moved while being rotated to conduct irradiation treatment again, and then transported out of the reactor. The device comprises a rotational conveying shaft for moving the irradiated capsule while rotating it, a conveying gear for U-turning the irradiated capsule in the reactor and inserting it to the conveying shaft and a driving mechanism for synchronously rotating the conveying gear relative to the conveying shaft at a constant ratio. Mechanical time loss and manual operation time loss can be reduced upon loading and taking up of the irradiated capsule. Then, the amount of irradiation treatment per unit time is increased, and an optional neutron irradiation amount can be obtained thereby enabling to reduce operator's radiation exposure. (N.H.)

  17. Design and testing of tubular polymeric capsules for self-healing of concrete

    Science.gov (United States)

    Araújo, M.; Van Tittelboom, K.; Feiteira, J.; Gruyaert, E.; Chatrabhuti, S.; Raquez, J.-M.; Šavija, B.; Alderete, N.; Schlangen, E.; De Belie, N.

    2017-10-01

    Polymeric healing agents have proven their efficiency to heal cracks in concrete in an autonomous way. However, the bottleneck for valorisation of self-healing concrete with polymeric healing agents is their encapsulation. In the present work, the suitability of polymeric materials such as poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(lactic acid) (PLA) as carriers for healing agents in self-healing concrete has been evaluated. The durability of the polymeric capsules in different environments (demineralized water, salt water and simulated concrete pore solution) and their compatibility with various healing agents have been assessed. Next, a numerical model was used to simulate capsule rupture when intersected by a crack in concrete and validated experimentally. Finally, two real-scale self-healing concrete beams were made, containing the selected polymeric capsules (with the best properties regarding resistance to concrete mixing and breakage upon crack formation) or glass capsules and a reference beam without capsules. The self-healing efficiency was determined after crack creation by 3-point-bending tests.

  18. Utility of capsule endoscopy for evaluating anthelmintic efficacy in fully conscious dogs.

    Science.gov (United States)

    Lee, Alice C Y; Epe, Christian; Simpson, Kenneth W; Bowman, Dwight D

    2011-11-01

    The current accepted standard for evaluating the efficacy of gastrointestinal anthelmintic drugs is necropsy of infected animals followed by a comparison of worm counts between treated and non-treated groups. In this study capsule endoscopy, a minimally invasive method of imaging the small intestine of humans, is evaluated as a possible alternative to necropsy for the purposes of worm quantification in dogs. Eighteen Beagle dogs were included in this study. These dogs were part of a separate trial intended to determine the efficacy of various candidate parasiticides against Ancylostoma caninum via the necropsy standard. Dogs were inoculated with A. caninum L3s 4 weeks prior to treatment with one of the candidate compounds; a control group (n=8) received no treatment. Capsule endoscopy was performed 6-14 days post-treatment, followed by necropsy the following day. Seventeen dogs had complete examinations, i.e. the capsule traversed the small intestine and reached the colon within the battery life of the capsule. A strong correlation (r(s)=0.87, Pcapsule endoscopy and necropsy. There was no clear relationship between the ability of the capsule endoscope to detect hookworms and either visibility of the intestinal lumen or small intestinal transit time. Generation of a virtual spatial record of hookworm location from the capsule endoscopy data revealed a temporal trend, with the majority of worms present in the proximal small intestine in the morning versus the central to distal small intestine in the afternoon. Worm distribution as determined by capsule endoscopy closely resembled post-mortem findings. In conclusion, capsule endoscopy shows promise as an alternative to necropsy for the enumeration of A. caninum in the canine small intestine, although further work is required to improve completion rates and optimise intestinal examination. Copyright © 2011 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

  19. Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges

    Directory of Open Access Journals (Sweden)

    Guobing Pan

    2012-01-01

    Full Text Available Wireless capsule endoscopy (WCE offers a feasible noninvasive way to detect the whole gastrointestinal (GI tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE is the bottleneck. Wireless power transmission (WPT is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed.

  20. Capsule performance optimization in the National Ignition Campaigna)

    Science.gov (United States)

    Landen, O. L.; Boehly, T. R.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Hoffman, N.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Kyrala, G. A.; Michel, P.; Milovich, J.; Munro, D. H.; Nikroo, A.; Olson, R. E.; Robey, H. F.; Spears, B. K.; Thomas, C. A.; Weber, S. V.; Wilson, D. C.; Marinak, M. M.; Suter, L. J.; Hammel, B. A.; Meyerhofer, D. D.; Atherton, J.; Edwards, J.; Haan, S. W.; Lindl, J. D.; MacGowan, B. J.; Moses, E. I.

    2010-05-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  1. Capsule performance optimization in the National Ignition Campaign

    International Nuclear Information System (INIS)

    Landen, O. L.; Bradley, D. K.; Braun, D. G.; Callahan, D. A.; Celliers, P. M.; Collins, G. W.; Dewald, E. L.; Divol, L.; Glenzer, S. H.; Hamza, A.; Hicks, D. G.; Izumi, N.; Jones, O. S.; Kirkwood, R. K.; Michel, P.; Milovich, J.; Munro, D. H.; Robey, H. F.; Spears, B. K.; Thomas, C. A.

    2010-01-01

    A capsule performance optimization campaign will be conducted at the National Ignition Facility [G. H. Miller et al., Nucl. Fusion 44, 228 (2004)] to substantially increase the probability of ignition by laser-driven hohlraums [J. D. Lindl et al., Phys. Plasmas 11, 339 (2004)]. The campaign will experimentally correct for residual uncertainties in the implosion and hohlraum physics used in our radiation-hydrodynamic computational models before proceeding to cryogenic-layered implosions and ignition attempts. The required tuning techniques using a variety of ignition capsule surrogates have been demonstrated at the OMEGA facility under scaled hohlraum and capsule conditions relevant to the ignition design and shown to meet the required sensitivity and accuracy. In addition, a roll-up of all expected random and systematic uncertainties in setting the key ignition laser and target parameters due to residual measurement, calibration, cross-coupling, surrogacy, and scale-up errors has been derived that meets the required budget.

  2. Technology Insight: current status of video capsule endoscopy.

    Science.gov (United States)

    Cave, David R

    2006-03-01

    Video capsule endoscopy (VCE) is the most recent major practical and conceptual development in the field of endoscopy. The video capsule endoscope-a small, pill-sized, passive imaging device-has been demonstrated to be the pre-eminent imaging device for disorders of the small intestine. The initial use for VCE was to detect the origin of obscure gastrointestinal bleeding. Several other indications have now been justified, or are in the process of evaluation. More than 200,000 of these disposable devices have been used worldwide, with an extraordinarily good safety record: indeed, the device has been approved for use in children as young as 10 years of age. In addition, a double-ended capsule has now been approved for the evaluation of mucosal disease in the esophagus. The now-widespread deployment of the device into gastrointestinal practice in the US and many other countries suggests that VCE has achieved mainstream utility. The development of similar competitor devices, and devices whose movement can be controlled, is in progress.

  3. Structure and selectivity trends in crystalline urea-functionalized anion-binding capsules

    Energy Technology Data Exchange (ETDEWEB)

    Rajbanshi, Arbin [Oak Ridge National Laboratory (ORNL); Custelcean, Radu [ORNL

    2012-01-01

    A tripodal trisurea receptor (L1) persistently self-assembles with various divalent oxoanion salts M{sub n}X (M = Na, K, Mg, Ca, Cd; X = SO{sub 4}{sup 2-}, SO{sub 3}{sup 2-}, SeO{sub 4}{sup 2-}, CrO{sub 4}{sup 2-}) into isomorphous series of crystalline frameworks in three different compositions: MX(L1){sub 2}(H{sub 2}O){sub 6} (M = Mg, Ca, Cd) (1), Na{sub 2}X(L1){sub 2}(H{sub 2}O){sub 4} (2) and K{sub 2}X(L1){sub 2}(H{sub 2}O){sub 2} (3). Single-crystal X-ray structural analysis revealed that all three series of structures adopt a NaCl-type topology, consisting of alternating anionic X(L1){sub 2}{sup 2-} capsules and M(H{sub 2}O){sub 6}{sup 2+}, Na{sub 2}(H{sub 2}O){sub 4}{sup 2+} or K{sub 2}(H{sub 2}O){sub 2}{sup 2+} hydrated cations. The capsules provide a complementary environment to tetrahedral oxoanions via 12 hydrogen bonds from six urea groups lining the cavities of the capsules. The persistent formation of the capsules facilitated the investigation of structural trends and structure-selectivity relationships across series 1-3. First, it was found that the size of the capsules is relatively unresponsive to the change in the encapsulated anion, resulting in good shape and size recognition in the separation of anions by competitive crystallizations. Second, it was found that the size of the capsules varies linearly with the size of the external cation, which provides a way for tuning the anion encapsulation selectivity. However, no straightforward dependence was found between the size of the capsules and the relative selectivity for different-sized tetrahedral oxoanions in competitive crystallizations.

  4. Assessment of patency capsule retention using MR diffusion-weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne [Sheba Medical Center, Department of Diagnostic Imaging, Ramat Gan (Israel); Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami [Tel Aviv University, Sackler Faculty of Medicine, Tel Aviv (Israel); Sheba Medical Center, Department of Gastroenterology, Ramat Gan (Israel)

    2017-12-15

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm{sup 2}/s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  5. Assessment of patency capsule retention using MR diffusion-weighted imaging

    International Nuclear Information System (INIS)

    Klang, Eyal; Rozendorn, Noa; Amitai, Michal Marianne; Kopylov, Uri; Ben-Horin, Shomron; Lahat, Adi; Yablecovitch, Doron; Eliakim, Rami

    2017-01-01

    Evaluate the ability of MR diffusion-weighted imaging (DWI) to predict patency capsule retention in Crohn's disease (CD). Clinical and imaging data were prospectively reviewed for 80 CD patients following patency capsule administration and MR-DWI under institutional review board (IRB) approval with informed consent. Two radiologists separately assessed the presence/absence of restricted diffusion in the distal ileum. Apparent diffusion coefficients (ADC) from three regions of interest on the ileal wall were averaged. The association between restricted diffusion and retention, and sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. Ability of ADC to predict retention was assessed with receiver operating characteristic (ROC) curve analysis. Restricted diffusion in the distal ileum was associated with capsule retention (p = 0.001, p < 0.0001). Sensitivity, specificity, PPV and NPV of restricted diffusion for capsule retention were 100.0%, 46.2%, 30.0%, 100% and 100.0%, 56.9%, 34.9%, 100%, respectively, for two radiologists. Accuracy of ADC to predict retention was high (area under the curve = 0.851, p < 0.0001). An ADC of 1.47 mm 2 /s showed 90.0% sensitivity and 50.0% specificity for retention. Sensitivity and NPV of restricted diffusion for patency capsule retention were 100%, suggesting that DWI may predict gastrointestinal tract capability to pass video camera endoscopy. (orig.)

  6. Development of a design methodology for hydraulic pipelines carrying rectangular capsules

    International Nuclear Information System (INIS)

    Asim, Taimoor; Mishra, Rakesh; Abushaala, Sufyan; Jain, Anuj

    2016-01-01

    The scarcity of fossil fuels is affecting the efficiency of established modes of cargo transport within the transportation industry. Efforts have been made to develop innovative modes of transport that can be adopted for economic and environmental friendly operating systems. Solid material, for instance, can be packed in rectangular containers (commonly known as capsules), which can then be transported in different concentrations very effectively using the fluid energy in pipelines. For economical and efficient design of such systems, both the local flow characteristics and the global performance parameters need to be carefully investigated. Published literature is severely limited in establishing the effects of local flow features on system characteristics of Hydraulic Capsule Pipelines (HCPs). The present study focuses on using a well validated Computational Fluid Dynamics (CFD) tool to numerically simulate the solid-liquid mixture flow in both on-shore and off-shore HCPs applications including bends. Discrete Phase Modelling (DPM) has been employed to calculate the velocity of the rectangular capsules. Numerical predictions have been used to develop novel semi-empirical prediction models for pressure drop in HCPs, which have then been embedded into a robust and user-friendly pipeline optimisation methodology based on Least-Cost Principle. - Highlights: • Local flow characteristics in a pipeline transporting rectangular capsules. • Development of prediction models for the pressure drop contribution of capsules. • Methodology developed for sizing of Hydraulic Capsule Pipelines. • Implementation of the developed methodology to obtain optimal pipeline diameter.

  7. The roles of Tenascin C and Fibronectin 1 in adhesive capsulitis: a pilot gene expression study

    Directory of Open Access Journals (Sweden)

    Carina Cohen

    Full Text Available OBJECTIVES: We evaluated mRNA expression levels of genes that encode TGF-β1; the TGF-β1 receptor; the collagen-modifying enzymes LOX, PLOD1, and PLOD2; and the extracellular matrix proteins COMP, FN1, TNC and TNXB in synovial/capsule specimens from patients with idiopathic adhesive capsulitis. Possible associations between the measured mRNA levels and clinical parameters were also investigated. METHODS: We obtained glenohumeral joint synovium/capsule specimens from 9 patients with idiopathic adhesive capsulitis who had not shown improvement in symptoms after 5 months of physiotherapy. Adhesive capsulitis was confirmed in all patients by magnetic resonance imaging. We also obtained specimens from 8 control patients who had underwent surgery for acute acromioclavicular joint dislocation and who had radiological indication of glenohumeral capsule alteration based on arthroscopic evaluation. mRNA expression in the synovium/capsule specimens was analyzed by quantitative reverse transcription PCR. The B2M and HPRT1 genes were used as references to normalize target gene expression in the shoulder tissue samples. RESULTS: The synovium/capsule samples from the patients with adhesive capsulitis had significantly higher TNC and FN1 expression than those from the controls. Additionally, symptom duration directly correlated with expression of TGFβ1 receptor I. CONCLUSION: Elevated levels of TNC and FN1 expression may be a marker of capsule injury. Upregulation of TGFβ1 receptor I seems to be dependent on symptom duration; therefore, TGFβ signaling may be involved in adhesive capsulitis. As such, TNC, FN1 and TGFβ1 receptor I may also play roles in adhesive capsulitis by contributing to capsule inflammation and fibrosis.

  8. Collapse of experimental capsules under external pressure

    International Nuclear Information System (INIS)

    Simonen, F.A.; Shippell, R.J. Jr.

    1980-01-01

    Stress analyses and developmental tests of capsules fabricated from thick-walled tubing were performed for an external pressure design condition. In the design procedure no credit was taken for the expected margin in pressure between yielding of the capsule wall and catastrophic collapse or flattening. In tests of AISI-1018 low carbon steel capsules, a significant margin was seen between yield and collapse pressure. However, the experimental yield pressures were significantly below predictions, essentially eliminating the safety margin present in the conservative design approach. The differences between predictions and test results are attributed to deficiencies in the plasticity theories commonly in use for engineering stress analyses. The results of this study show that the von Mises yield condition does not accurately describe the yield behavior of the AISI-1018 steel tubing material for the triaxial stress conditions of interest. Finite element stress analyses successfully predicted the transition between uniform inward plastic deformation and ovalization that leads to catastrophic collapse. After adjustments to correct for the unexpected yield behavior of the tube material, the predicted pressure-deflection trends were found to follow the experimental data

  9. The application value of capsule endoscopy in diagnosing small intestinal carcinoma

    Directory of Open Access Journals (Sweden)

    Xiaohuan Li

    2018-01-01

    Conclusion: Capsule endoscopy demonstrated a high diagnostic value for various small bowel diseases, including both tumor and inflammatory lesions. Given its simplicity, safety, and reliability, capsule endoscopy was an important examination tool for the diagnosis of small bowel diseases.

  10. Colon Cancer Detection by ‘Rendezvous Colonoscopy’: Successful Removal of Stuck Colon Capsule by Conventional Colonoscopy

    Directory of Open Access Journals (Sweden)

    István Rácz

    2010-02-01

    Full Text Available Although capsule retention is a known complication of small bowel capsule endoscopy, initial studies with colon capsule endoscopy (CCE have not reported any capsule retention or sticking neither in the small bowel nor in the colon. We report a complication of CCE when the stuck colon capsule was passed through the malignant colon stricture and removed by the aid of a flexible colonoscope. During CCE in a 76-year-old iron deficiency anemia patient the real-time viewing system indicated the colon capsule to be stuck in a malignant ascending colon stricture for more than two hours. With the aim to avoid complete capsule retention, immediate colonoscopy was performed. The stuck capsule was caught by a polypectomy snare, passed through the tumor stricture and finally removed from the large bowel. The current case describes the usefulness of the real-time viewing system. Similar situations may occur during the forthcoming spread of CCE and the present case is an example of how to manage the potentially risky stuck colon capsule condition.

  11. El consumo de tabaco como símbolo de libertad femenina: análisis de las estrategias publicitarias utilizadas por Virginia Slims

    OpenAIRE

    Sánchez Pérez, Sonia

    2018-01-01

    Desde que el tabaco comenzó a industrializarse, las compañías tabacaleras trataron de aumentar sus ventas a través de la publicidad. En un primer momento, el consumo de cigarrillos estaba destinado únicamente a los hombres, pero los movimientos sufragistas y feministas pronto adoptaron el consumo de cigarrillos como símbolo de libertad femenina. Veremos la evolución histórica del tabaco y de su publicidad y analizaremos el caso concreto de la marca estadounidense Virginia Slims...

  12. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    Science.gov (United States)

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Science.gov (United States)

    Caboni, Mariaelena; Pédron, Thierry; Rossi, Omar; Goulding, David; Pickard, Derek; Citiulo, Francesco; MacLennan, Calman A; Dougan, Gordon; Thomson, Nicholas R; Saul, Allan; Sansonetti, Philippe J; Gerke, Christiane

    2015-03-01

    Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg) of the lipopolysaccharide (LPS) plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  14. An O antigen capsule modulates bacterial pathogenesis in Shigella sonnei.

    Directory of Open Access Journals (Sweden)

    Mariaelena Caboni

    2015-03-01

    Full Text Available Shigella is the leading cause for dysentery worldwide. Together with several virulence factors employed for invasion, the presence and length of the O antigen (OAg of the lipopolysaccharide (LPS plays a key role in pathogenesis. S. flexneri 2a has a bimodal OAg chain length distribution regulated in a growth-dependent manner, whereas S. sonnei LPS comprises a monomodal OAg. Here we reveal that S. sonnei, but not S. flexneri 2a, possesses a high molecular weight, immunogenic group 4 capsule, characterized by structural similarity to LPS OAg. We found that a galU mutant of S. sonnei, that is unable to produce a complete LPS with OAg attached, can still assemble OAg material on the cell surface, but a galU mutant of S. flexneri 2a cannot. High molecular weight material not linked to the LPS was purified from S. sonnei and confirmed by NMR to contain the specific sugars of the S. sonnei OAg. Deletion of genes homologous to the group 4 capsule synthesis cluster, previously described in Escherichia coli, abolished the generation of the high molecular weight OAg material. This OAg capsule strongly affects the virulence of S. sonnei. Uncapsulated knockout bacteria were highly invasive in vitro and strongly inflammatory in the rabbit intestine. But, the lack of capsule reduced the ability of S. sonnei to resist complement-mediated killing and to spread from the gut to peripheral organs. In contrast, overexpression of the capsule decreased invasiveness in vitro and inflammation in vivo compared to the wild type. In conclusion, the data indicate that in S. sonnei expression of the capsule modulates bacterial pathogenesis resulting in balanced capabilities to invade and persist in the host environment.

  15. H2 gas pressure calculation of FPM capsule failure at RSG-GAS reactor core

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji; Sunaryo, Geni Rina

    2002-01-01

    RSG-GAS has been irradiated FPM capsule for 236 times, one of those i.e. capsule number 228 has failure. The one of root cause of failure possibility is radiolysis reaction can be occurred in FPM capsule when it is filled with water during irradiation in the reactor core. The safety analysis of the radiolysis reaction in the capsule has been done. The oc cumulative hydrogen gas production can cause high pressure in the capsule then a mechanical damage occurred. The analysis was done at 10 MW of reactor power which equivalent with neutron flux of 0,6929 x 10 1 4 n/cm 2 sec and γ dose rate of 0,63x10 9 rad/hour. The assumption is the capsule is filled with water at maximum volume, i.e. 176.67 ml. The results of calculation showed that radiolysis reaction with γ and neutron produce hydrogen gas for nominal flow rate each are 494 atm and 19683 atm for γ and neutron radiolysis, respectively. H 2 gas pressure for 5% flow rate each are 723 atm. and 25772 atm., for γ and neutron radiolysis, respectively. The changing of the operation condition due to radiolysis together with one way valve' phenomena, can be produce hydrogen gas from water during irradiation in the reactor core and can be the one of root cause of capsule failure. This analysis recommended the FPM capsule preparation must be guaranteed no water or/and there is no possibility of water immersion in the capsule during irradiation in the core by more accurate leak test

  16. Ignition capsules with aerogel-supported liquid DT fuel for the National Ignition Facility

    Directory of Open Access Journals (Sweden)

    Ho D.D.-M.

    2013-11-01

    Full Text Available For high repetition-rate fusion power plant applications, capsules with aerogel-supported liquid DT fuel can have much reduced fill time compared to β-layering a solid DT fuel layer. The melting point of liquid DT can be lowered once liquid DT is embedded in an aerogel matrix, and the DT vapor density is consequently closer to the desired density for optimal capsule design requirement. We present design for NIF-scale aerogel-filled capsules based on 1-D and 2-D simulations. An optimal configuration is obtained when the outer radius is increased until the clean fuel fraction is within 65 – 75% at peak velocity. A scan (in ablator and fuel thickness parameter space is used to optimize the capsule configurations. The optimized aerogel-filled capsule has good low-mode robustness and acceptable high-mode mix.

  17. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  18. Effects of compound amino acids capsule on the immunological function of naval servicemen

    Directory of Open Access Journals (Sweden)

    Hai-zhong ZHONG

    2012-01-01

    Full Text Available Objective  To investigate the effects of the compound amino acids capsule on the immunological function of the naval servicemen during military activity. Methods  The subjects included 100 officers and soldiers, whose Modified Fatigue Rating Scale (MFIS scores were >21 points. The participants were randomly divided into two groups, namely, the amino acids capsule group and placebo group (n=50. Under the condition of military operations, either amino acids capsule (8 kinds of essential amino acids and 11 kinds of vitamins were contained or placebo capsule was given for 14 days continuously. The humoral immune indices, i.e., IgG, IgA, IgM, and complements C3 and C4, were measured with immunoturbidimetry. The percentage of peripheral blood CD subsets was measured using flow cytometry on the first day and 14th day. Results  The levels of IgG, IgM, and complement C3 in the capsule group were significantly higher on the 14th day than on the first day (P+CD4+ T lymphocytes and CD3-CD19+ B lymphocytes in the capsule group on the 14th day were higher than those on the first day, whereas the CD3-CD56+ NK lymphocytes decreased significantly (PConclusion  Compound amino acids capsule can improve the humoral and cellular immunological function of naval servicemen.

  19. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  20. Capsules with evolving brittleness to resist the preparation of self-healing concrete

    Directory of Open Access Journals (Sweden)

    Gruyaert, E.

    2016-09-01

    Full Text Available Capsules for self-healing concrete have to possess multifunctional properties and it would be an enormous advantage in the valorization process when they could also be mixed in. Therefore, we aimed to develop capsules with evolving brittleness. Capsules with high initial flexibility were prepared by adding a plasticizer to an ethyl cellulose matrix. During hardening of the concrete, the plasticizing agent should leach out to the moist environment yielding more brittle capsules which break upon crack appearance. The tested capsules could easily be mixed in during concrete production. However, incompatibility issues between the capsule wall and the inner polymeric healing agent appeared. Moreover, the capsules became insufficiently brittle and the bond strength to the cementitious matrix was too weak. Consequently, multilayer capsules were tested. These capsules had a high impact resistance to endure concrete mixing and were able to break upon crack formation.Las cápsulas para la auto-reparación del hormigón tienen que poseer propiedades multifuncionales. Una enorme ventaja en el proceso para su valorización se obtendría si aquellas pudieran resistir con éxito el mezclado. Por lo tanto, nos propusimos desarrollar cápsulas cuya fragilidad evoluciona. Cápsulas con una alta flexibilidad inicial se prepararon mediante la adición de un plastificante a una matriz de etil celulosa. Durante el endurecimiento del hormigón, el agente plastificante debe filtrarse hacia el medio ambiente húmedo produciendo cápsulas más frágiles que se rompen con el surgimiento de fisuras. Las cápsulas pudieron ser fácilmente mezcladas durante la producción de hormigón. Sin embargo, aparecieron problemas de incompatibilidad entre la pared de la cápsula y el agente de curación polimérico interior. Por otra parte, las cápsulas se comportaron insuficientemente frágiles y con una baja adherencia hacia la matriz cementicia. En consecuencia, se probaron las c

  1. Small-bowel capsule endoscopy in patients with suspected Crohn's disease-diagnostic value and complications.

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  2. Welding iridium heat-source capsules for space missions

    International Nuclear Information System (INIS)

    Kanne, W.R. Jr.

    1982-03-01

    A remote computer-controlled welding station was developed to encapsulate radioactive PuO 2 in iridium. Weld quench cracking caused an interruption in production of capsules for upcoming space missions. Hot crack sensitivity of the DOP-26 iridium alloy was associated with low melting constituents in the grain boundaries. The extent of cracking was reduced but could not be eliminated by changes to the welding operation. An ultrasonic test was developed to detect underbead cracks exceeding a threshold size. Production was continued using the ultrasonic test to reject capsules with detectable cracks

  3. Capsule of parotid gland tumor: evaluation by 3.0 T magnetic resonance imaging using surface coils

    International Nuclear Information System (INIS)

    Ishibashi, Mana; Fujii, Shinya; Nishihara, Keisuke; Matsusue, Eiji; Kodani, Kazuhiko; Kaminou, Toshio; Ogawa, Toshihide; Kawamoto, Katsuyuki

    2010-01-01

    Background: Magnetic resonance (MR) imaging of parotid gland tumors has been widely reported, although few reports have evaluated the capsule of parotid gland tumors in detail. Purpose: To evaluate the diagnostic usefulness of 3.0 T MR imaging with surface coils for detection of the parotid gland tumor capsule, and to clarify the characteristics of the capsules. Material and Methods: Seventy-eight patients with parotid gland tumors (63 benign and 15 malignant) were evaluated. Axial and coronal T2-weighted and contrast-enhanced T1-weighted images were obtained using a 3.0 T MR scanner with 70 mm surface coils. It was retrospectively assessed whether each parotid gland tumor was completely surrounded by a capsule. The capsule was classified as regular or irregular in terms of capsular thickness, and as none, mildly, or strongly enhancing in terms of contrast enhancement. Visual interpretations were compared with histopathological findings to evaluate the diagnostic ability of MR imaging to detect parotid gland tumor capsules. Statistical evaluation was conducted concerning the presence of capsules, capsular irregularity, and the difference in contrast enhancement between benign and malignant tumors, and that between pleomorphic adenomas and Warthin's tumors. Results: Capsules completely surrounding the tumor on MR imaging yielded a sensitivity of 87.7% (50/57), specificity of 90.5% (19/21), and accuracy of 88.5% (69/78). Benign tumors had a capsule completely surrounding the tumor significantly more often than malignant tumors (P = 0.009). Concerning capsular irregularity, malignant tumors tended to have more irregular capsules than benign tumors, although there were no significant differences. The capsules of malignant tumors enhanced significantly more strongly than those of benign tumors (P = 0.018). Conclusion: 3.0 T MR imaging using surface coils could correctly depict parotid gland tumor capsules in most cases. Most benign and some malignant tumors had capsules

  4. Fabrication of mechanical system of the FPM capsule puller

    International Nuclear Information System (INIS)

    Sudirdjo, Hari; Prasetya, Hendra

    2000-01-01

    A mechanical system of the FPM capsule puller has been fabricated, which has a function to pull the irradiated FPM capsule. The construction of the system consist of driving motor equipped with reduction gear, spindle, and puller wire. The system has puller stroke of 700 mm, therefore the puller will be terminated at the outside of the reactor core. A function test had been done and shows that the system has fulfilled the requirements

  5. Neuro-fuzzy Classification System for Wireless-Capsule Endoscopic Images

    OpenAIRE

    Vassilis S. Kodogiannis; John N. Lygouras

    2008-01-01

    In this research study, an intelligent detection system to support medical diagnosis and detection of abnormal lesions by processing endoscopic images is presented. The images used in this study have been obtained using the M2A Swallowable Imaging Capsule - a patented, video color-imaging disposable capsule. Schemes have been developed to extract texture features from the fuzzy texture spectra in the chromatic and achromatic domains for a selected region of interest from ...

  6. A modular and programmable development platform for capsule endoscopy system.

    Science.gov (United States)

    Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A

    2014-06-01

    The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.

  7. Identification of adulterants in a Chinese herbal medicine by LC-HRMS and LC-MS-SPE/NMR and comparative in vivo study with standards in a hypertensive rat model.

    Science.gov (United States)

    Kesting, Julie Regitze; Huang, Jingqi; Sørensen, Dan

    2010-02-05

    Based on anecdotal evidence of anti-hypertensive effect of Gold Nine Soft Capsules, an in vivo study of this complex Chinese "herbal-based" medicine was initiated. Dosage of the content of Gold Nine capsules in spontaneous hypertensive rats showed a remarkably good effect. This led to further investigation of the components of the preparation and eventual identification of three known anti-hypertensive drugs; amlodipine, indapamide and valsartan, which were not declared on the label. Compounds were rapidly identified using LC-HRMS and LC-MS-SPE/NMR, quantified by HPLC, and the in vivo activity of a combination of commercially purchased standards was shown to be equivalent to that of the capsule content. Adulteration of herbal remedies and dietary supplements with synthetic drugs is an increasing problem that may lead to serious adverse effects. LC-MS-SPE/NMR as a method for the rapid identification of such adulterants is highlighted in this case study.

  8. Effects of lipophilic components on the compatibility of lipid-based formulations with hard gelatin capsules.

    Science.gov (United States)

    Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S

    2010-01-01

    The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of

  9. Simulation-Aided Design of Tubular Polymeric Capsules for Self-Healing Concrete

    Science.gov (United States)

    Šavija, Branko; Feiteira, João; Araújo, Maria; Chatrabhuti, Sutima; Raquez, Jean-Marie; Van Tittelboom, Kim; Gruyaert, Elke; De Belie, Nele; Schlangen, Erik

    2016-01-01

    Polymeric capsules can have an advantage over glass capsules used up to now as proof-of-concept carriers in self-healing concrete. They allow easier processing and afford the possibility to fine tune their mechanical properties. Out of the multiple requirements for capsules used in this context, the capability of rupturing when crossed by a crack in concrete of a typical size is one of the most relevant, as without it no healing agent is released into the crack. This study assessed the fitness of five types of polymeric capsules to fulfill this requirement by using a numerical model to screen the best performing ones and verifying their fitness with experimental methods. Capsules made of a specific type of poly(methyl methacrylate) (PMMA) were considered fit for the intended application, rupturing at average crack sizes of 69 and 128 μm, respectively for a wall thickness of ~0.3 and ~0.7 mm. Thicker walls were considered unfit, as they ruptured for crack sizes much higher than 100 μm. Other types of PMMA used and polylactic acid were equally unfit for the same reason. There was overall good fitting between model output and experimental results and an elongation at break of 1.5% is recommended regarding polymers for this application. PMID:28772370

  10. Renal capsule for augmentation cystoplasty in canine model: a favorable biomaterial?

    Directory of Open Access Journals (Sweden)

    Mehdi Salehipour

    2016-04-01

    Full Text Available ABSTRACT Purpose: To evaluate effectiveness of canine renal capsule for augmentation cystoplasty. Materials and Methods: Ten adult dogs participated in this study. After induction of anesthesia each animal underwent bed side urodynamic study, bladder capacity and bladder pressure was recorded. Then via mid line incision abdominal cavity was entered, right kidney was identified and its capsule was dissected. Bladder augmentation was done by anastomosing the renal capsule to the bladder. After 6 months bed side urodynamic study was performed again and changes in bladder volume and pressure were recorded. Then the animals were sacrificed and the augmented bladders were sent for histopathology evaluation. Results: Mean maximum anatomic bladder capacity before cystoplasty was 334.00±11.40cc which increased to 488.00±14.83cc post-operatively (p=0.039. Mean anatomic bladder pressure before cystoplasty was 19.00±1.58cmH2O which decreased to 12.60±1.14cmH2O post-operatively (p=0.039. Histopathology evaluation revealed epithelialization of the renal capsule with urothelium without evidence of fibrosis, collagen deposits or contracture. Conclusions: Our data shows that renal capsule is a favorable biomaterial for bladder augmentation in a canine model.

  11. Vibration test report on the instrumented capsule for fuel irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Wu, J. S.; Oh, J. M.; Park, S. J.; Cho, M. S.; Kim, B. G.; Kang, Y. W

    2003-01-01

    The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of the accelerations was measured as 12.04m/s{sup 2} that is within the allowable vibrational limit(18.99m/s{sup 2})of the reactor structure. Also, the maximum displacement amplitude was calculated as 0.191mm. Since these vibration levels are remarkably low, excessive vibration is not expected when the irradiation test of the instrumented capsule is performed at the HANARO core.

  12. Thulium oxide fuel characterization study (thulium-170 fueled capsule parametric design)

    Energy Technology Data Exchange (ETDEWEB)

    DesChamps, N.H.

    1968-10-01

    A doubly encapsulated thulia wafer, i.e., individually lined wafers stacked one upon another inside a fuel capsule was studied. The temperature profiles were determined for thulia power densities ranging from 8 to 24 W/cc and fuel capsule surface temperatures ranging from 1000/sup 0/F (538/sup 0/C) to 2000/sup 0/F (1093/sup 0/C). Parametric studies were also carried out on a singly encapsulated configuration in which the thulia wafers were stacked face to face in an infinitely long, lined cylinder. The doubly encapsulated wafer configuration yielded a lower centerline temperature than the singly encapsulated capsule. Only in extreme cases of a large wafer diameter in combination with a high thulia power density did the fuel capsule centerline temperature exceed the thulia melt temperature of 4172/sup 0/F (2300/sup 0/C). Results are also given for the maximum radius attainable without having centerline melting when using a thulia microsphere fuel form.

  13. Protective effects of traditional Chinese medicine formula NaoShuanTong capsule on haemorheology and cerebral energy metabolism disorders in rats with blood stasis.

    Science.gov (United States)

    Liu, Hong; Peng, Yao-Yao; Liang, Feng-Yin; Chen, Si; Li, Pei-Bo; Peng, Wei; Liu, Zhong-Zheng; Xie, Cheng-Shi; Long, Chao-Feng; Su, Wei-Wei

    2014-01-02

    NaoShuanTong capsule (NSTC), an oral traditional Chinese medicine formula, is composed of Pollen Typhae , Radix Paeoniae Rubra , Rhizoma Gastrodiae , Radix Rhapontici and Radix Curcumae . It has been widely used to treat ischemic stroke in clinic for many years in China. In addition to neuronal apoptosis, haemorheology and cerebral energy metabolism disorders also play an important role in the pathogenesis and development of ischemic stroke. The present study was designed to evaluate the in vivo protective effects of NSTC on haemorheology and cerebral energy metabolism disorders in rats with blood stasis. Sixty specific pathogen-free sprague-dawley rats, male only, were randomly divided into six groups (control group, model group, aspirin (100 mg/kg/d) group, NSTC low-dose (400 mg/kg/d) group, NSTC intermediate-dose (800 mg/kg/d) group, NSTC high-dose (1600 mg/kg/d) group) with 10 animals in each. The rats except those in the control group were placed in ice-cold water (0-4 °C) for 5 min during the time interval (4 h) of two adrenaline hydrochloride injections (0.8 mg/kg) to induce blood stasis. After treatment, whole blood viscosity at three shear rates, plasma viscosity and erythrocyte sedimentation rate significantly decreased in NSTC intermediate- and high-dose groups; erythrocyte aggregation index and red corpuscle electrophoresis index significantly decreased in all the three dose NSTC groups. Moreover, treatment with high-dose NSTC could significantly improve Na + -K + adenosine triphosphatase (ATPase) and Ca 2+ ATPase activity, as well as lower lactic acid level in brain tissues. These results demonstrated the protective effects of NSTC on haemorheology and cerebral energy metabolism disorders, which may provide scientific information for the further understanding of mechanism(s) of NSTC as a clinical treatment for ischemic stroke. Furthermore, the protective effects of activating blood circulation as observed in this study might create valuable

  14. Validating Inertial Confinement Fusion (ICF) predictive capability using perturbed capsules

    Science.gov (United States)

    Schmitt, Mark; Magelssen, Glenn; Tregillis, Ian; Hsu, Scott; Bradley, Paul; Dodd, Evan; Cobble, James; Flippo, Kirk; Offerman, Dustin; Obrey, Kimberly; Wang, Yi-Ming; Watt, Robert; Wilke, Mark; Wysocki, Frederick; Batha, Steven

    2009-11-01

    Achieving ignition on NIF is a monumental step on the path toward utilizing fusion as a controlled energy source. Obtaining robust ignition requires accurate ICF models to predict the degradation of ignition caused by heterogeneities in capsule construction and irradiation. LANL has embarked on a project to induce controlled defects in capsules to validate our ability to predict their effects on fusion burn. These efforts include the validation of feature-driven hydrodynamics and mix in a convergent geometry. This capability is needed to determine the performance of capsules imploded under less-than-optimum conditions on future IFE facilities. LANL's recently initiated Defect Implosion Experiments (DIME) conducted at Rochester's Omega facility are providing input for these efforts. Recent simulation and experimental results will be shown.

  15. Trade study for the disposition of cesium and strontium capsules

    International Nuclear Information System (INIS)

    Claghorn, R.D.

    1996-03-01

    This trade study analyzes alternatives for the eventual disposal of cesium and strontium capsules currently stored at the Waste Encapsulation and Storage Facility as by-product. However, for purposes of this study, it is assumed that at some time in the future, the capsules will be declared high-level waste and therefore will require disposal at an offsite geologic repository. The study considered numerous alternatives and selected three for detailed analysis: (1) overpack and storage at high-level waste canister storage building, (2) overpack at the high-level waste vitrification facility followed by storage at a high-level waste canister storage building, and (3) blend capsule contents with other high-level waste feed streams and vitrify at the high-level waste vitrification facility

  16. Capsule-Preserving Hydrodilatation With Corticosteroid Versus Corticosteroid Injection Alone in Refractory Adhesive Capsulitis of Shoulder: A Randomized Controlled Trial.

    Science.gov (United States)

    Lee, Doo-Hyung; Yoon, Seung-Hyun; Lee, Michael Y; Kwack, Kyu-Sung; Rah, Ueon Woo

    2017-05-01

    To determine whether capsule-preserved hydrodilatation with corticosteroid improves pain and function in patients with refractory adhesive capsulitis (AC) better than intra-articular corticosteroid injection (IACI) alone. Prospective randomized controlled study. University-affiliated tertiary care hospital. Subjects with primary AC (N=64) with shoulder pain level of visual analog scale (VAS) score ≥5, even after the initial administration of IACI alone. Participants randomly received ultrasound-guided IACI alone with 1mL of 40mg/mL triamcinolone acetonide and 3mL of 1% lidocaine (n=32) or ultrasound-guided capsule-preserved hydrodilatation with corticosteroid with a mixture of 1mL of 40mg/mL triamcinolone acetonide, 6mL of 1% lidocaine, and normative saline (n=32). The primary outcome measure was the Shoulder Pain and Disability Index score. Secondary outcomes were the VAS of shoulder pain level and angles of shoulder passive range of motion, including flexion, abduction, extension, external rotation, and internal rotation at pretreatment and weeks 3, 6, and 12 of posttreatment. There were no significant differences between the 2 groups in terms of demographic characteristics (age, sex, duration of symptoms, shoulder affected, and body mass index) at baseline. Repeated-measures analysis of variance showed significant effect of time in all outcome measurements in both groups. However, group-by-time interactions were not significantly different for any of the outcomes between groups. This study shows that compared with pretreatment, all outcome measures improved significantly in both groups by time; however, there was no significant difference between the 2 groups. Therefore, we recommend IACI alone over capsule-preserved hydrodilatation with corticosteroid when considering the corticosteroid injection as a secondary option after the initial IACI fails to improve symptoms for patients with refractory AC. Copyright © 2016 American Congress of Rehabilitation

  17. Sensitive Detection of Deliquescent Bacterial Capsules through Nanomechanical Analysis.

    Science.gov (United States)

    Nguyen, Song Ha; Webb, Hayden K

    2015-10-20

    Encapsulated bacteria usually exhibit strong resistance to a wide range of sterilization methods, and are often virulent. Early detection of encapsulation can be crucial in microbial pathology. This work demonstrates a fast and sensitive method for the detection of encapsulated bacterial cells. Nanoindentation force measurements were used to confirm the presence of deliquescent bacterial capsules surrounding bacterial cells. Force/distance approach curves contained characteristic linear-nonlinear-linear domains, indicating cocompression of the capsular layer and cell, indentation of the capsule, and compression of the cell alone. This is a sensitive method for the detection and verification of the encapsulation status of bacterial cells. Given that this method was successful in detecting the nanomechanical properties of two different layers of cell material, i.e. distinguishing between the capsule and the remainder of the cell, further development may potentially lead to the ability to analyze even thinner cellular layers, e.g. lipid bilayers.

  18. SrF2 capsule design for heat engine applications

    International Nuclear Information System (INIS)

    Lester, D.H.

    1976-04-01

    A number of design changes were considered to improve heat transfer characteristics of the WESF capsule. This capsule was evaluated in a design concept for use as a heat source in a helium-working fluid, Stirling heat engine. Throughout the study a heat block concept was used. The helium was assumed to be at 1200 0 F and 200 atm. The upper temperature limit at the fuel-metal interface was assumed to be 800 0 C because of material compatibility considerations. A 0.6-in. thick outer can was considered since it may be required for impact resistance and high pressure accident environments. The modifications considered were: (1) filling all gaps with helium rather than air, (2) filling gaps with powdered metal, and (3) adding a third can to the existing capsule. Also, enhancement of emissivity on metal surfaces was considered as a possible modification

  19. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Science.gov (United States)

    Figueiredo, Pedro; Almeida, Nuno; Lopes, Sandra; Duque, Gabriela; Freire, Paulo; Lérias, Clotilde; Gouveia, Hermano; Sofia, Carlos

    2010-01-01

    Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD). Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%). The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy. PMID:20811612

  20. Small-Bowel Capsule Endoscopy in Patients with Suspected Crohn's Disease—Diagnostic Value and Complications

    Directory of Open Access Journals (Sweden)

    Pedro Figueiredo

    2010-01-01

    Full Text Available Background. The aim of this work was to assess the value of capsule enteroscopy in the diagnosis of patients with suspected Crohn's Disease (CD. Methods. This was a retrospective study in a single tertiary care centre involving patients undergoing capsule enteroscopy for suspected CD. Patients taking nonsteroidal anti inflammatory drugs during the thirty preceding days or with a follow-up period of less than six months were excluded. Results. Seventy eight patients were included. The endoscopic findings included mucosal breaks in 50%, ulcerated stenosis in 5%, and villous atrophy in 4%. The diagnosis of CD was established in 31 patients. The sensitivity, specificity, positive and negative predictive value of the endoscopic findings were 93%, 80%, 77%, and 94%, respectively. Capsule retention occurred in four patients (5%. The presence of ulcerated stenosis was significantly more frequent in patients with positive inflammatory markers. The diagnostic yield of capsule enteroscopy in patients with negative ileoscopy was 56%, with a diagnostic acuity of 93%. Conclusions. Small bowel capsule endoscopy is a safe and valid technique for assessing patients with suspected CD. Capsule retention is more frequent in patients with positive inflammatory markers. Patients with negative ileoscopy and suspected CD should be submitted to capsule enteroscopy.

  1. A generalized scaling law for the ignition energy of inertial confinement fusion capsules

    International Nuclear Information System (INIS)

    Herrmann, M.C.

    2001-01-01

    The minimum energy needed to ignite an inertial confinement fusion capsule is of considerable interest in the optimization of an inertial fusion driver. Recent computational work investigating this minimum energy has found that it depends on the capsule implosion history, in particular, on the capsule drive pressure. This dependence is examined using a series of LASNEX simulations to find ignited capsules which have different values of the implosion velocity, fuel adiabat and drive pressure. It is found that the main effect of varying the drive pressure is to alter the stagnation of the capsule, changing its stagnation adiabat, which, in turn, affects the energy required for ignition. To account for this effect a generalized scaling law has been devised for the ignition energy, E ign ∝α if 1.88±0.05 υ -5.89±0.12 P -0.77±0.03 . This generalized scaling law agrees with the results of previous work in the appropriate limits. (author)

  2. Work plan for testing silicone impression material and fixture on pool cell capsule

    International Nuclear Information System (INIS)

    Lundeen, J.E.

    1994-01-01

    The purpose of this work plan is to provide a safe procedure to test a cesium capsule impression fixture at Waste Encapsulation and Storage Facility (WESF). The impression will be taken with silicone dental impression material pressed down upon the capsule using the impression fixture. This test will evaluate the performance of the fixture and impression material under high radiation and temperature conditions on a capsule in a WESF pool cell

  3. Additional effective dose by patients undergoing NAI-131 capsules therapy

    Energy Technology Data Exchange (ETDEWEB)

    Orlic, M.; Jovanovic, M.; Spasic Jokic, V.; Cuknic, O.; Ilic, Z.; Vranjes Djuric, S. [VINCA - Institute of Nuclear Sciences, Belgrade, Serbia and Montenegro (Yugoslavia)

    2006-07-01

    Capsules or solutions containing Na{sup 131}I are indicated for the therapy of some thyroid carcinomas such as functioning metastatic papillary or follicular carcinoma of the thyroid; and for the treatment of hyperthyroidism (diffuse toxic goiter and single or multiple toxic nodular goiter). The recommended dosage ranges of Na{sup 131}I capsules or solution for the therapy of the average patient (70 kg) are: (3.7-5.55) GBq for ablation of normal thyroid tissue; (3.7-7.4) GBq for subsequent treatments; a (148-370) MBq for hyperthyroidism. The purpose of this paper is to calculate effective dose as a result of iodine-131 capsules remaining in stomach before absorption starts. This result can determine the disadvantage of capsule versus solution containing sodium iodine-131 (Na{sup 131}I) in radionuclide therapy application from radiation protection point of view. The Monte Carlo code MCNP4b was used to model transport of gamma and beta particles emitted by radionuclide {sup 131}I treated as a point source at the bottom of stomach. Absorbed energy per unit transformation in stomach and surrounding organs has been calculated. (authors)

  4. Comparison of thyroid uptake of 131I capsule and solution in rabbits and graves disease patients

    International Nuclear Information System (INIS)

    Zhou Xinjian; Li Fang; Lu Jingqiao; Chen Daming; Zhang Ruilin

    2002-01-01

    Objective: To observe the difference between thyroid uptake rates (TUR) of 131 I capsule and solution in rabbits and Graves disease patients. Methods: Part one: 6 rabbits randomized into two groups received capsule or solution of 131 I 7.4 MBq. Then with SPECT scintigraphy 2,4,6 and 24 h thyroid pure counts in percentage of stomach counts (first frame) were determined. Part two: 1) Measured 131 I capsule standard. 2) 104 patients with Graves disease were administered tracing and therapeutic dose of 131 I capsule (capsule group), 118 of 131 I solution (solution group). Compared the tracing and therapeutic 131 I TUR at 24 h. Results: Part one: There were no significant difference at 2,4,6,24 h TUR between capsule and solution group. For 1 case the maximum TUR was at 6 h in capsule group and 2 cases in solution groups. Part two: 1) For the 131 I capsule administered immediately after being dissolved in 30 mL of water, the activity counts measured were higher by (13.8 +- 2.8)% than it was administered directly, t8.97, P 0.05) and in solution group were (71.3 +- 12.3)% and (65.1 +- 13.0)% (t = 3.82, P 131 I capsule standard should be dissolved before being measured. 3) 131 I capsules can be used as a standard formulation for Graves disease patients. 4) The dose of 131 I should be increased as tracer TUR is larger than 80.0%

  5. Ultrahigh speed en face OCT capsule for endoscopic imaging.

    Science.gov (United States)

    Liang, Kaicheng; Traverso, Giovanni; Lee, Hsiang-Chieh; Ahsen, Osman Oguz; Wang, Zhao; Potsaid, Benjamin; Giacomelli, Michael; Jayaraman, Vijaysekhar; Barman, Ross; Cable, Alex; Mashimo, Hiroshi; Langer, Robert; Fujimoto, James G

    2015-04-01

    Depth resolved and en face OCT visualization in vivo may have important clinical applications in endoscopy. We demonstrate a high speed, two-dimensional (2D) distal scanning capsule with a micromotor for fast rotary scanning and a pneumatic actuator for precision longitudinal scanning. Longitudinal position measurement and image registration were performed by optical tracking of the pneumatic scanner. The 2D scanning device enables high resolution imaging over a small field of view and is suitable for OCT as well as other scanning microscopies. Large field of view imaging for screening or surveillance applications can also be achieved by proximally pulling back or advancing the capsule while scanning the distal high-speed micromotor. Circumferential en face OCT was demonstrated in living swine at 250 Hz frame rate and 1 MHz A-scan rate using a MEMS tunable VCSEL light source at 1300 nm. Cross-sectional and en face OCT views of the upper and lower gastrointestinal tract were generated with precision distal pneumatic longitudinal actuation as well as proximal manual longitudinal actuation. These devices could enable clinical studies either as an adjunct to endoscopy, attached to an endoscope, or as a swallowed tethered capsule for non-endoscopic imaging without sedation. The combination of ultrahigh speed imaging and distal scanning capsule technology could enable both screening and surveillance applications.

  6. Thermal Analysis of a Dry Storage Concept for Capsule Dry Storage Project

    International Nuclear Information System (INIS)

    JOSEPHSON, W.S.

    2003-01-01

    There are 1,936 cesium (Cs) and strontium (Sr) capsules stored in pools at the Waste Encapsulation and Storage Facility (WESF). These capsules will be moved to dry storage on the Hanford Site as an interim measure to reduce risk. The Cs/Sr Capsule Dry Storage Project is conducted under the assumption that the capsules will eventually be moved to the repository at Yucca Mountain, and the design criteria include requirements that will facilitate acceptance at the repository. The storage system must also permit retrieval of capsules in the event that vitrification of the capsule contents is pursued. The Capsule Advisory Panel (CAP) was created by the Project Manager for the Hanford Site Capsule Dry Storage Project (CDSP). The purpose of the CAP is to provide specific technical input to the CDSP; to identify design requirements; to ensure design requirements for the project are conservative and defensible; to identify and resolve emerging, critical technical issues, as requested; and to support technical reviews performed by regulatory organizations, as requested. The CAP will develop supporting and summary documents that can be used as part of the technical and safety bases for the CDSP. The purpose of capsule dry storage thermal analysis is to: (1) Summarize the pertinent thermal design requirements sent to vendors, (2) Summarize and address the assumptions that underlie those design requirements, (3) Demonstrate that an acceptable design exists that satisfies the requirements, (4) Identify key design features and phenomena that promote or impede design success, (5) Support other CAP analyses such as corrosion and integrity evaluations, and (6) Support the assessment of proposed designs. It is not the purpose of this report to optimize or fully analyze variations of postulated acceptable designs. The present evaluation will indicate the impact of various possible design features, but not systematically pursue design improvements obtainable through analysis

  7. The position control of a capsule filled with magnetic fluid

    International Nuclear Information System (INIS)

    Rhee, E.J.; Park, M.K.; Yamane, R.; Oshima, S.

    2002-01-01

    In this paper, in order to establish the technique of a nozzle-flapper system of a servo valve using magnetic fluid in hydraulic system, a governing equation regarding the levitation of a capsule filled with magnetic fluid is formulated. Using PID control, an experiment for the position control of a capsule was performed. The experimental results were compared with the simulation results found by the governing equation

  8. Interventional microadhesiolysis: A new nonsurgical release technique for adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Lim Tae-Kyun

    2008-01-01

    Full Text Available Abstract Background A nonsurgical intervention, interventional microadhesiolysis, was developed to release adhesions in joints and soft tissues. This paper introduces the procedure and evaluates the efficacy of the intervention for adhesive capsulitis of the shoulder. Methods Ten patients (five men and five women with primary adhesive capsulitis of the shoulder were treated at a chronic pain management center in Korea. Three specially made needles are used in interventional microadhesiolysis: the Round, Flexed Round, and Ahn's needles. A Round Needle is inserted on the skin over middle of supraspinatus and advanced under the acromion and acromioclavicular joint (subacromial release. A Flexed Round Needle is inserted two-fingers caudal to the inferior border of the scapular spine and advanced over the capsule sliding on the surface of infraspinatus muscle-tendon fascia. The capsule is released while an assistant simultaneously passively abducts the shoulder to full abduction (posteroinferior capsule release. An Ahn's Needle is inserted on the skin over the lesser tubercle and advanced under the coracoid process sliding on the surface of the subscapularis muscle (subcoracoid release. Results After the patients underwent interventional microadhesiolysis, the self-rated pain score or severity declined significantly (p p Conclusion Our findings suggest that interventional microadhesiolysis is effective for managing adhesive capsulitis of the shoulder.

  9. Simultaneous determination of phenolic acids and diterpenoids and their comparative pharmacokinetic study in normal and acute blood stasis rats by UFLC-MS/MS after oral administration of Guan-Xin-Shu-Tong capsules.

    Science.gov (United States)

    Gao, Xun; Mu, Jingqing; Guan, Shaoyi; Li, Qing; Du, Yiyang; Zhang, Huifen; Bi, Kaishun

    2018-01-01

    Guan-Xin-Shu-Tong capsules are one of the well-known and first-line Chinese traditional herbal formula for treating coronary heart disease. A validated and sensitive method via ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) was established to simultaneously determinate five phenolic acids and four diterpenoids in rats in order to investigate their pharmacokinetic profiles firstly. Analytes were extracted by ethyl acetate and determined via multiple reaction monitoring mode in both positive and negative ion modes. The values for limit of quantification were in range of 0.025-1.250ng/ml. Inter- and intra-day precisions were no more than 10.9% with accuracy of -11.0%-10.6%, meanwhile the stable and suitable extraction recoveries were also obtained. And finally such excellent method was used to compare the pharmacokinetics of nine compounds in normal and acute blood stasis rats after oral administration of Guan-Xin-Shu-Tong capsules. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Matrix polyelectrolyte capsules based on polysaccharide/MnCO₃ hybrid microparticle templates.

    Science.gov (United States)

    Wei, Qingrong; Ai, Hua; Gu, Zhongwei

    2011-06-15

    An efficient strategy for biomacromolecule encapsulation based on spontaneous deposition into polysaccharide matrix-containing capsules is introduced in this study. First, hybrid microparticles composed of manganese carbonate and ionic polysaccharides including sodium hyaluronate (HA), sodium alginate (SA) and dextran sulfate sodium (DS) with narrow size distribution were synthesized to provide monodisperse templates. Incorporation of polysaccharide into the hybrid templates was successful as verified by thermogravimetric analysis (TGA) and confocal laser scanning microscopy (CLSM). Matrix polyelectrolyte microcapsules were fabricated through layer-by-layer (LbL) self-assembly of oppositely charged polyelectrolytes (PEs) onto the hybrid particles, followed by removal of the inorganic part of the cores, leaving polysaccharide matrix inside the capsules. The loading and release properties of the matrix microcapsules were investigated using myoglobin as a model biomacromolecule. Compared to matrix-free capsules, the matrix capsules had a much higher loading capacity up to four times; the driving force is mostly due to electrostatic interactions between myoglobin and the polysaccharide matrix. From our observations, for the same kind of polysaccharide, a higher amount of polysaccharide inside the capsules usually led to better loading capacity. The release behavior of the loaded myoglobin could be readily controlled by altering the environmental pH. These matrix microcapsules may be used as efficient delivery systems for various charged water-soluble macromolecules with applications in biomedical fields. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Egg capsules of the dusky catshark Bythaelurus canescens (Carcharhiniformes, Scyliorhinidae) from the south-eastern Pacific Ocean.

    Science.gov (United States)

    Concha, F; Bustamante, C; Oddone, M C; Hernández, S; Lamilla, J

    2010-09-01

    The external morphology of the egg capsule of Bythaelurus canescens and its fixation to the substratum are described. Bythaelurus canescens egg capsules are typically vase-shaped, dorso-ventrally flattened, pale yellow in colour when fresh and covered by 12-15 longitudinal ridges. The anterior border of the capsule is straight, whereas the posterior border is semicircular. Two horns bearing long, coiled tendrils arise from the anterior and posterior ends of the capsule. The presence of longitudinal ridges and long coiled tendrils at both anterior and posterior ends of the capsule readily distinguish these egg capsules from those of other chondrichthyans occurring in the south-east Pacific Ocean. © 2010 The Authors. Journal compilation © 2010 The Fisheries Society of the British Isles.

  12. Structural analysis on the open basket type instrumented capsule for fuel irradiation tests in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Sik; Kang, Y. H.; Kim, B. G.; Cho, M. S.; Sohn, J. M.; Choo, K. N.; Oh, J. M.; Shin, Y. T.; Park, S. J. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-05-01

    To develop the open basket type instrumented capsule to be used for the irradiation test of various nuclear fuels, it is necessary to ensure the compatibility of the capsule with HANARO and the structural integrity of the capsule. The dimensions of the open basket type instrumented capsule were determined in the basis of the pressure drop criteria in OR test hole of HANARO(mass flow rate <12.7kg/s, pressure drop {delta}P>200kPa). From the buckling stability analysis for this capsule, the critical buckling load P{sub cr} was 7.5kN. The vertical impact stress of the capsule under unit impact load was evaluated by the transient analysis, and the maximum vertical impact load calculated from the impact stress and the allowable stress was 60.5kN. Under the loading of the calculated Pcr, the maximum vertical impact stress was 20.4MPa. The structural integrity of the capsule under a horizontal impact loading was also examined. The mechanical stresses occurred by the pressure difference at the inner and outer surface of cladding and by the coolant pressure at the surface of cladding were 3.1MPa and 43.3MPa, respectively. These stress values were lower than the allowable stress in each case. Therefore, it was ensured that the instrumented capsule for the irradiation test of various nuclear fuels met the criteria on the structural integrity during installing and testing the capsule in HANARO. 8 refs., 61 figs., 3 tabs. (Author)

  13. Design and Output Performance Model of Turbodrill Blade Used in a Slim Borehole

    Directory of Open Access Journals (Sweden)

    Yu Wang

    2016-12-01

    Full Text Available Small-diameter turbodrills have great potential for use in slim boreholes because of their lower cost and higher efficiency when used in geothermal energy and other underground resource applications. Multistage hydraulic components consisting of stators and rotors are key aspects of turbodrills. This study aimed to develop a suitable blade that can be used under high temperature in granite formations. First, prediction models for single- and multi-stage blades were established based on Bernoulli’s Equation. The design requirement of the blade for high-temperature geothermal drilling in granite was proposed. A Φ89 blade was developed based on the dimensionless parameter method and Bezier curve; the parameters of the blade, including its radial size, symotric parameters, and blade profiles, were input into ANASYS and CFX to establish a calculation model of the single-stage blade. The optimization of the blade structure of the small-diameter turbodrill enabled a multistage turbodrill model to be established and the turbodrill’s overall output performance to be predicted. The results demonstrate that the design can meet the turbodrill’s performance requirements and that the multistage model can effectively improve the accuracy of the prediction.

  14. Evaluation of the quality consistency of powdered poppy capsule extractive by an averagely linear-quantified fingerprint method in combination with antioxidant activities and two compounds analyses.

    Science.gov (United States)

    Zhang, Yujing; Sun, Guoxiang; Hou, Zhifei; Yan, Bo; Zhang, Jing

    2017-12-01

    A novel averagely linear-quantified fingerprint method was proposed and successfully applied to monitor the quality consistency of alkaloids in powdered poppy capsule extractive. Averagely linear-quantified fingerprint method provided accurate qualitative and quantitative similarities for chromatographic fingerprints of Chinese herbal medicines. The stability and operability of the averagely linear-quantified fingerprint method were verified by the parameter r. The average linear qualitative similarity SL (improved based on conventional qualitative "Similarity") was used as a qualitative criterion in the averagely linear-quantified fingerprint method, and the average linear quantitative similarity PL was introduced as a quantitative one. PL was able to identify the difference in the content of all the chemical components. In addition, PL was found to be highly correlated to the contents of two alkaloid compounds (morphine and codeine). A simple flow injection analysis was developed for the determination of antioxidant capacity in Chinese Herbal Medicines, which was based on the scavenging of 2,2-diphenyl-1-picrylhydrazyl radical by antioxidants. The fingerprint-efficacy relationship linking chromatographic fingerprints and antioxidant activities was investigated utilizing orthogonal projection to latent structures method, which provided important pharmacodynamic information for Chinese herbal medicines quality control. In summary, quantitative fingerprinting based on averagely linear-quantified fingerprint method can be applied for monitoring the quality consistency of Chinese herbal medicines, and the constructed orthogonal projection to latent structures model is particularly suitable for investigating the fingerprint-efficacy relationship. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Method and apparatus for dispensing small quantities of mercury from evacuated and sealed glass capsules

    Science.gov (United States)

    Grossman, Mark W.; George, William A.; Pai, Robert Y.

    1985-01-01

    A technique for opening an evacuated and sealed glass capsule containing a material that is to be dispensed which has a relatively high vapor pressure such as mercury. The capsule is typically disposed in a discharge tube envelope. The technique involves the use of a first light source imaged along the capsule and a second light source imaged across the capsule substantially transversely to the imaging of the first light source. Means are provided for constraining a segment of the capsule along its length with the constraining means being positioned to correspond with the imaging of the second light source. These light sources are preferably incandescent projection lamps. The constraining means is preferably a multiple looped wire support.

  16. Capsule Typing of Haemophilus influenzae by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Månsson, Viktor; Gilsdorf, Janet R; Kahlmeter, Gunnar; Kilian, Mogens; Kroll, J Simon; Riesbeck, Kristian; Resman, Fredrik

    2018-03-01

    Encapsulated Haemophilus influenzae strains belong to type-specific genetic lineages. Reliable capsule typing requires PCR, but a more efficient method would be useful. We evaluated capsule typing by using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Isolates of all capsule types (a-f and nontypeable; n = 258) and isogenic capsule transformants (types a-d) were investigated. Principal component and biomarker analyses of mass spectra showed clustering, and mass peaks correlated with capsule type-specific genetic lineages. We used 31 selected isolates to construct a capsule typing database. Validation with the remaining isolates (n = 227) showed 100% sensitivity and 92.2% specificity for encapsulated strains (a-f; n = 61). Blinded validation of a supplemented database (n = 50) using clinical isolates (n = 126) showed 100% sensitivity and 100% specificity for encapsulated strains (b, e, and f; n = 28). MALDI-TOF mass spectrometry is an accurate method for capsule typing of H. influenzae.

  17. Physics of ignition for ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    The implosion of an ICF capsule must accomplish both compression of the main fuel to several hundred grams per cubic centimeter and heating and compression of the central region of the fuel to ignition. This report discusses the physics of these conditions

  18. Radiation research of materials using irradiation capsules

    International Nuclear Information System (INIS)

    Chamrad, B.

    1976-01-01

    The methods are briefly characterized of radiation experiments on the WWR-S research reactor. The irradiation capsule installed in the reactor including the electronic instrumentation is described. Irradiated samples temperature is stabilized by an auxiliary heat source placed in the irradiation space. The electronic control equipment of the system is automated. In irradiation experiments, experimental and operating conditions are recorded by a digital measuring centre with electric typewriter and paper tape data recording and by an analog compensating recorder. The irradiation experiment control system controls irradiated sample temperature, the supply current size and the heating element temperature of the auxiliary stabilizing source, inert and technological pressures of the capsule atmosphere and the thermostat temperature of the thermocouple junctions. (O.K.)

  19. Review of safety issues that pertain to the use of WESF cesium chloride capsules in an irradiator

    International Nuclear Information System (INIS)

    Tingey, G.L.; Wheelwright, E.J.; Lytle, J.M.

    1984-07-01

    Since the recovery of the fission product cesium-137 began in 1967, about 1500 capsules, each containing an average of about 50,000 curies of cesium chloride, have been produced. These capsules were designed to safely store this gamma-emitting fission product, but they are now considered to be a valuable source for irradiators. The capsules were designed to have a large margin of safety in their mechanical properties. Impact, percussion, and thermal tests have been conducted that demonstrate their ability to meet anticipated licensing requirements. Although this document is not intended to develop or evaluate accident scenarios, an examination of the effects of heating a capsule to 800 0 C for up to 90 min was completed. At 800 0 C, the salt volume would be expected to exceed the initial capsule volume in a few (up to 1/3) of the WESF capsules. Under these conditions, the inner capsule would expand to accommodate the salt volume and the gas pressure. The strength and ductility of the capsule are more than adequate to permit this expansion with a safety margin of at least a factor of three. Capsules have now been stored in the WESF pool for 10 years, and 15 capsules have been used in the Sandia Irradiator for Dried Sewage Solids facility for nearly 5 years without any capsule failure. This experience, along with available laboratory and production data, gives reasonable assurance that the capsules can be safely used in properly designed commercial irradiators. This is especially the case when one considers current and future evaluation programs designed to assess the long-term effects of corrosion and mechanical properties degradation

  20. Fabrication, characterization and evaluation of bacterial cellulose-based capsule shells for oral drug delivery

    DEFF Research Database (Denmark)

    Ullah, Hanif; Badshah, Munair; Mäkilä, Ermei

    2017-01-01

    Bacterial cellulose (BC) was investigated for the first time for the preparation of capsule shells for immediate and sustained release of drugs. The prepared capsule shells were characterized using X-ray diffraction, scanning electron microscopy and Fourier transform infrared spectroscopy. The BC...... to gelatin capsules with both immediate and sustained drug release properties depending upon the compositions of the encapsulated materials....

  1. A study for the development of the capsule assembly machine for the re-irradiation test

    International Nuclear Information System (INIS)

    Kang, Y. H.; Kim, J. K.; Yeom, K. Y.; Yoon, K. B.; Choi, M. H.; Kim, B. K.

    2004-01-01

    A series of in-pile tests are being carried out to support the advanced fuel development programs at the HANARO reactor. There are still some limitations for satisfying the test requirements. To meet the demands for the high burnup test at HANARO, new capsule assembling technology is required. This paper describes the design requirements, design and fabrication of the mockup, and pre-operational tests performed for the development of the new capsule assembly machine. The mockup manufactured consists of a base plate, a capsule stand, a capsule guide pipe and clamping device and is 1m in outer diameter, 1.8m in height and 136kg in weight. From the pre-operation tests, the optimum clamping torque was 450kgf·cm for preventing rotation and shaking of the capsule main body during assembling capsule main body and protection tube, and this remote assembling procedure can be applicable to the high burnup test

  2. Summary of the irradiation history of the TRIST-ER1 capsule

    Energy Technology Data Exchange (ETDEWEB)

    Qualls, A.L.; Eatherly, W.S.; Heatherly, D.W. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    The TRIST-ERI capsule was assembled and irradiated in a large Removable Beryllium (RB{star}) position of the High Flux Isotope Reactor (HFIR) during this reporting period. Irradiation began on March 8, 1996, was completed on June 20, 1996, during operating cycles 344, 345, and 346. This report describes the thermal operation of the capsule.

  3. The design, fabrication, and testing of beryllium capsules for resonant ultrasound experiments

    International Nuclear Information System (INIS)

    Salazar, M.A.; Salzer, L.; Day, R.

    1999-01-01

    Inertial Confinement Fusion (ICF) ignition targets require smooth and well-characterized deuterium/tritium (DT) ice layers. Los Alamos is developing Resonant Ultrasound Spectroscopy (RUS) to measure the internal pressure in the targets at room temperature after filling with DT. RUS techniques also can detect and measure the amplitudes of low modal surface roughness perturbations of the target shell interior. The experiments required beryllium capsules with a nominal inside radius of 1 mm and a spherical outside radius of 3 mm. The capsules have various spherical harmonic contours up to mode 12 machined into their interior surfaces. The capsules are constructed from hemispheres using an epoxy adhesive and then filled to ∼270 atm with helium or deuterium gas. This paper describes the adhesive joint design, machining techniques, and interior geometry inspection techniques. It also describes the fixtures needed to assemble, fill, and pressure test the capsules

  4. An Automated Self-Learning Quantification System to Identify Visible Areas in Capsule Endoscopy Images.

    Science.gov (United States)

    Hashimoto, Shinichi; Ogihara, Hiroyuki; Suenaga, Masato; Fujita, Yusuke; Terai, Shuji; Hamamoto, Yoshihiko; Sakaida, Isao

    2017-08-01

    Visibility in capsule endoscopic images is presently evaluated through intermittent analysis of frames selected by a physician. It is thus subjective and not quantitative. A method to automatically quantify the visibility on capsule endoscopic images has not been reported. Generally, when designing automated image recognition programs, physicians must provide a training image; this process is called supervised learning. We aimed to develop a novel automated self-learning quantification system to identify visible areas on capsule endoscopic images. The technique was developed using 200 capsule endoscopic images retrospectively selected from each of three patients. The rate of detection of visible areas on capsule endoscopic images between a supervised learning program, using training images labeled by a physician, and our novel automated self-learning program, using unlabeled training images without intervention by a physician, was compared. The rate of detection of visible areas was equivalent for the supervised learning program and for our automatic self-learning program. The visible areas automatically identified by self-learning program correlated to the areas identified by an experienced physician. We developed a novel self-learning automated program to identify visible areas in capsule endoscopic images.

  5. Semipermeable Capsules Wrapping a Multifunctional and Self-regulated Co-culture Microenvironment for Osteogenic Differentiation

    Science.gov (United States)

    Correia, Clara R.; Pirraco, Rogério P.; Cerqueira, Mariana T.; Marques, Alexandra P.; Reis, Rui L.; Mano, João F.

    2016-02-01

    A new concept of semipermeable reservoirs containing co-cultures of cells and supporting microparticles is presented, inspired by the multi-phenotypic cellular environment of bone. Based on the deconstruction of the “stem cell niche”, the developed capsules are designed to drive a self-regulated osteogenesis. PLLA microparticles functionalized with collagen I, and a co-culture of adipose stem (ASCs) and endothelial (ECs) cells are immobilized in spherical liquified capsules. The capsules are coated with multilayers of poly(L-lysine), alginate, and chitosan nano-assembled through layer-by-layer. Capsules encapsulating ASCs alone or in a co-culture with ECs are cultured in endothelial medium with or without osteogenic differentiation factors. Results show that osteogenesis is enhanced by the co-encapsulation, which occurs even in the absence of differentiation factors. These findings are supported by an increased ALP activity and matrix mineralization, osteopontin detection, and the up regulation of BMP-2, RUNX2 and BSP. The liquified co-capsules also act as a VEGF and BMP-2 cytokines release system. The proposed liquified capsules might be a valuable injectable self-regulated system for bone regeneration employing highly translational cell sources.

  6. In vitro evaluation of extemporaneously compounded slow-release capsules containing morphine sulfate or oxycodone hydrochloride.

    Science.gov (United States)

    Glowiak, Dana L; Green, Julie L; Bowman, Bill J

    2005-01-01

    The in vitro performance of extemporaneously compounded morphine sulfate and oxycodone hydrochloride slow-release capsules was evaluated. Capsules containing varying amoutns of morphine sulfate (15, 60, 200 mg) or oxycodone hydrochloride (10, 80, 200 mg) were prepared and provided by a Phoenix, Arizona, pharmacy. The capsules also contained 40% Methocel E4M Premium to slow the release of their active ingredient and sufficient lactose to fill the capsules. Three batches of each capsule strength were prepared, and replicates from each batch were evlauated using United Stated Pharmacopeia dissolution apparatus II. Samples were taken at regular time intervals over 24 hours. After 1 hour the pH of the dissolution medium was adjusted form 1.2 to 4.0, and after 2 hours the pH was adjusted to 6.8. The amount of drug released at each time point was determined spectrophotometrically. The compounded capsules released 14% to 23%, 67% to 85% and 93% to 98% of their active ingredient after 0.5, 4 and 12 hours, respectively. The relative standard deviations between the replicates from each batch were less than 10% for most time points. The percent of drug released over the first 4 hours was linear (r squared = 0.9409-0.9999) when plotted versus time 1/2, indicating adherence to the simplified Higuchi model. Statistical analysis of the Higuchi dissolution constants indicated a significant difference (P less than 0.05) between batch No.3 and the other two batches of 200-mg oxycodone hydrochloride capsules. There was also a statistical difference between most of the Higuchi dissolution constants for the different-strength slow-release capsules and most slow-release capsules and equivalent strength controlled-release manufactured tablets (P less than 0.05). Using 40% Methocel E4M Premium slowed the release of morphine sulfate and oxycodone hydrochloride from extemporaneously compounded capsules. The in vitro performance of the slow-release capsules showed little intrabatch variation

  7. The Poly-γ-D-Glutamic Acid Capsule of Bacillus licheniformis, a Surrogate of Bacillus anthracis Capsule Induces Interferon-Gamma Production in NK Cells through Interactions with Macrophages.

    Science.gov (United States)

    Lee, Hae-Ri; Jeon, Jun Ho; Rhie, Gi-Eun

    2017-05-28

    The poly-γ- D -glutamic acid (PGA) capsule, a major virulence factor of Bacillus anthracis , provides protection of the bacterium from phagocytosis and allows its unimpeded growth in the host. We investigated crosstalk between murine natural killer (NK) cells and macrophages stimulated with the PGA capsule of Bacillus licheniformis , a surrogate of the B. anthracis capsule. PGA induced interferon-gamma production from NK cells cultured with macrophages. This effect was dependent on macrophage-derived IL-12 and cell-cell contact interaction with macrophages through NK cell receptor NKG2D and its ligand RAE-1. The results showed that PGA could enhance NK cell activation by inducing IL-12 production in macrophages and a contact-dependent crosstalk with macrophages.

  8. The effects of convergence ratio on the implosion behavior of DT layered inertial confinement fusion capsules

    Science.gov (United States)

    Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.

    2017-07-01

    The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).

  9. Design and manufacturing of non-instrumented capsule for advanced PWR fuel pellet irradiation test in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Song, K. W. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-04-01

    This project is preparing to irradiation test of the developed large grain UO{sub 2} fuel pellet in HANARO for pursuit fuel safety and high burn-up in 'Advanced LWR Fuel Technology Development Project' as a part Nuclear Mid and Long-term R and D Program. On the basis test rod is performed the nuclei property and preliminary fuel performance analysis, test rod and non-instrumented capsule are designed and manufactured for irradiation test in HANARO. This non-instrumented irradiation capsule of Advanced PWR Fuel pellet was referred the non-instrumented capsule for an irradiation test of simulated DUPIC fuel in HANARO(DUPIC Rig-001) and 18-element HANARO fuel, was designed to ensure the integrity and the endurance of non-instrumented capsule during the long term(2.5 years) irradiation. To irradiate the UO{sub 2} pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. This non-instrumented irradiation capsule will be based to develope the non-instrumented capsule for the more long term irradiation in HANARO. 22 refs., 13 figs., 5 tabs. (Author)

  10. Impacts of Implosion Asymmetry And Hot Spot Shape On Ignition Capsules

    Science.gov (United States)

    Cheng, Baolian; Kwan, Thomas J. T.; Wang, Yi-Ming; Yi, S. Austin; Batha, Steve

    2017-10-01

    Implosion symmetry plays a critical role in achieving high areal density and internal energy at stagnation during hot spot formation in ICF capsules. Asymmetry causes hot spot irregularity and stagnation de-synchronization that results in lower temperatures and areal densities of the hot fuel. These degradations significantly affect the alpha heating process in the DT fuel as well as on the thermonuclear performance of the capsules. In this work, we explore the physical factors determining the shape of the hot spot late in the implosion and the effects of shape on Î+/-particle transport. We extend our ignition theory [1-4] to include the hot spot shape and quantify the effects of the implosion asymmetry on both the ignition criterion and capsule performance. We validate our theory with the NIF existing experimental data Our theory shows that the ignition criterion becomes more restrictive with the deformation of the hot spot. Through comparison with the NIF data, we demonstrate that the shape effects on the capsules' performance become more explicit as the self-heating and yield of the capsules increases. The degradation of the thermonuclear burn by the hot spot shape for high yield shots to date can be as high as 20%. Our theory is in good agreement with the NIF data. This work was performed under the auspices of the U.S. Department of Energy by the Los Alamos National Laboratory under Contract No. W-7405-ENG-36.

  11. RbsR Activates Capsule but Represses the rbsUDK Operon in Staphylococcus aureus.

    Science.gov (United States)

    Lei, Mei G; Lee, Chia Y

    2015-12-01

    Staphylococcus aureus capsule is an important virulence factor that is regulated by a large number of regulators. Capsule genes are expressed from a major promoter upstream of the cap operon. A 10-bp inverted repeat (IR) located 13 bp upstream of the -35 region of the promoter was previously shown to affect capsule gene transcription. However, little is known about transcriptional activation of the cap promoter. To search for potential proteins which directly interact with the cap promoter region (Pcap), we directly analyzed the proteins interacting with the Pcap DNA fragment from shifted gel bands identified by electrophoretic mobility shift assay. One of these regulators, RbsR, was further characterized and found to positively regulate cap gene expression by specifically binding to the cap promoter region. Footprinting analyses showed that RbsR protected a DNA region encompassing the 10-bp IR. Our results further showed that rbsR was directly controlled by SigB and that RbsR was a repressor of the rbsUDK operon, involved in ribose uptake and phosphorylation. The repression of rbsUDK by RbsR could be derepressed by D-ribose. However, D-ribose did not affect RbsR activation of capsule. Staphylococcus aureus is an important human pathogen which produces a large number of virulence factors. We have been using capsule as a model virulence factor to study virulence regulation. Although many capsule regulators have been identified, the mechanism of regulation of most of these regulators is unknown. We show here that RbsR activates capsule by direct promoter binding and that SigB is required for the expression of rbsR. These results define a new pathway wherein SigB activates capsule through RbsR. Our results further demonstrate that RbsR inhibits the rbs operon involved in ribose utilization, thereby providing an example of coregulation of metabolism and virulence in S. aureus. Thus, this study further advances our understanding of staphylococcal virulence regulation

  12. AN ELECTROMAGNETIC PNEUMO CAPSULE SYSTEM FOR CONVEYING MINERALS AND MINE WASTES

    Energy Technology Data Exchange (ETDEWEB)

    Henry Liu; Charles W. Lenau

    2005-03-01

    The purpose of this project is to investigate the technical and economic feasibility of using a new and advanced pneumatic capsule pipeline (PCP) system for transporting minerals and mine wastes. The new system is different from conventional PCPs in two main respects: (1) it uses linear induction motors (LIMs) instead of blowers (fans) at the inlet of the pipeline to drive (pump) the capsules and the air through the pipeline; and (2) the capsules in the PCP have steel wheels running on steel rails as opposed to capsules in conventional systems, which use wheels with rubber tires running inside a pipe without rail. The advantage of using LIM pump instead of blower is that the former is non-intrusive and hence does not block the passage of capsules, enabling the system to run continuously without having to make the capsules bypass the pump. This not only simplifies the system but also enables the system to achieve much larger cargo throughput than that of PCPs using blowers, and use of LIMs as booster pumps which enables the system to have any length or to be used for transporting cargoes over practically any distance, say even one thousand kilometers or miles. An advantage of using steel wheels rolling on steel rails instead of using rubber tires rolling inside a pipeline is that the rolling friction coefficient and hence the use of energy is greatly reduced from that of conventional PCP systems. Moreover, rails enable easy control of capsule motion, such as switching capsules to a branch line by using railroad switching equipment. The advanced PCP system studied under this project uses rectangular conduits instead of circular pipe, having cross-sectional areas of 1 m by 1 m approximately. The system can be used for various transportation distances, and it can transport up to 50 million tonnes (metric tons) of cargo annually--the throughput of the largest mines in the world. Both an aboveground and an underground system were investigated and compared. The technical

  13. Biomechanical Effects of Acromioplasty on Superior Capsule Reconstruction for Irreparable Supraspinatus Tendon Tears.

    Science.gov (United States)

    Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q

    2016-01-01

    Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75

  14. Modular nuclear fuel element, modular capsule for a such element and fabrication process for a modular capsule

    International Nuclear Information System (INIS)

    Chotard, A.

    1988-01-01

    The nuclear fuel rod is made by a tubular casing closed at both ends and containing a series of modular capsules with little play with the casing and made by a jacket closed by porous plugs at both ends and containing a stack of fuel pellets [fr

  15. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    Energy Technology Data Exchange (ETDEWEB)

    Buice, E S; Alger, E T; Antipa, N A; Bhandarkar, S D; Biesiada, T A; Conder, A D; Dzenitis, E G; Flegel, M S; Hamza, A V; Heinbockel, C L; Horner, J; Johnson, M A; Kegelmeyer, L M; Meyer, J S; Montesanti, R C; Reynolds, J L; Taylor, J S; Wegner, P J

    2011-02-18

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 {micro}m diameter glass-core fill-tube that tapers down to a 10{micro} diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1{sigma}), which corresponds to approximately 5 {micro}m linear error on the capsule surface.

  16. 3D Surface Mapping of Capsule Fill-Tube Assemblies used in Laser-Driven Fusion Targets

    International Nuclear Information System (INIS)

    Buice, E.S.; Alger, E.T.; Antipa, N.A.; Bhandarkar, S.D.; Biesiada, T.A.; Conder, A.D.; Dzenitis, E.G.; Flegel, M.S.; Hamza, A.V.; Heinbockel, C.L.; Horner, J.; Johnson, M.A.; Kegelmeyer, L.M.; Meyer, J.S.; Montesanti, R.C.; Reynolds, J.L.; Taylor, J.S.; Wegner, P.J.

    2011-01-01

    This paper presents the development of a 3D surface mapping system used to measure the surface of a fusion target Capsule Fill-Tube Assembly (CFTA). The CFTA consists of a hollow Ge-doped plastic sphere, called a capsule, ranging in outer diameter between 2.2 mm and 2.6 mm and an attached 150 (micro)m diameter glass-core fill-tube that tapers down to a 10(micro) diameter at the capsule. The mapping system is an enabling technology to facilitate a quality assurance program and to archive 3D surface information of each capsule used in fusion ignition experiments that are currently being performed at the National Ignition Facility (NIF). The 3D Surface Mapping System is designed to locate and quantify surface features with a height of 50 nm and 300 nm in width or larger. Additionally, the system will be calibrated such that the 3D measured surface can be related to the capsule surface angular coordinate system to within 0.25 degree (1σ), which corresponds to approximately 5 (micro)m linear error on the capsule surface.

  17. Radiation as a processing aid for upgrading gelatin and gelatin capsules

    International Nuclear Information System (INIS)

    Patel, K.M.; Tantry, M.; Sharma, G.; Gopal, N.G.S.

    1979-01-01

    Gelatin for pharmaceutical use should not contain more than 1000 microorganisms per gram and must not contain pathogenic microorganisms like Salmonella species and E.Coli. For some biological studies spore free gelatin is essential. Locally available gelatin and gelatin capsules have been found to contain a good number of microorganisms. Gelatin and its capsules containing different colours were exposed to graded doses of radiation and stored at different temperatures. They were then examined for microbial content, disintegration characteristics, pH, viscosity and colour change. The study shows that radiation treatment is useful to upgrade microbiologically both gelatin and its capsules. This technique provides apparently a useful and economic method for producing spore free gelatin which in commerce is relatively expensive. (auth.)

  18. Radiation as a processing aid for upgrading gelatin and gelatin capsules

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K M; Tantry, M; Sharma, G; Gopal, N G.S. [Bhabha Atomic Research Centre, Bombay (India). ISOMED

    1979-01-01

    Gelatin for pharmaceutical use should not contain more than 1000 microorganisms per gram and must not contain pathogenic microorganisms like Salmonella species and E.Coli. For some biological studies spore free gelatin is essential. Locally available gelatin and gelatin capsules have been found to contain a good number of microorganisms. Gelatin and its capsules containing different colours were exposed to graded doses of radiation and stored at different temperatures. They were then examined for microbial content, disintegration characteristics, pH, viscosity and colour change. The study shows that radiation treatment is useful to upgrade microbiologically both gelatin and its capsules. This technique provides apparently a useful and economic method for producing spore free gelatin which in commerce is relatively expensive.

  19. Stochastic Capsule Endoscopy Image Enhancement

    Directory of Open Access Journals (Sweden)

    Ahmed Mohammed

    2018-06-01

    Full Text Available Capsule endoscopy, which uses a wireless camera to take images of the digestive tract, is emerging as an alternative to traditional colonoscopy. The diagnostic values of these images depend on the quality of revealed underlying tissue surfaces. In this paper, we consider the problem of enhancing the visibility of detail and shadowed tissue surfaces for capsule endoscopy images. Using concentric circles at each pixel for random walks combined with stochastic sampling, the proposed method enhances the details of vessel and tissue surfaces. The framework decomposes the image into two detailed layers that contain shadowed tissue surfaces and detail features. The target pixel value is recalculated for the smooth layer using similarity of the target pixel to neighboring pixels by weighting against the total gradient variation and intensity differences. In order to evaluate the diagnostic image quality of the proposed method, we used clinical subjective evaluation with a rank order on selected KID image database and compared it to state-of-the-art enhancement methods. The result showed that the proposed method provides a better result in terms of diagnostic image quality and objective quality contrast metrics and structural similarity index.

  20. A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule.

    Science.gov (United States)

    Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G

    2005-09-01

    The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.

  1. Demonstration of Polysaccharide Capsule in Campylobacter jejuni Using Electron Microscopy

    OpenAIRE

    Karlyshev, Andrey V.; McCrossan, Maria V.; Wren, Brendan W.

    2001-01-01

    Recently, we reported that Campylobacter jejuni, an important gastrointestinal pathogen, has the genetic determinants to produce a capsular polysaccharide (Karlyshev et al., Mol. Microbiol. 35:529–541, 2000). Despite these data, the presence of a capsule in these bacteria has remained controversial. In this study we stain C. jejuni cells with the cationic dye Alcian blue and demonstrate for the first time by electron microscopy that C. jejuni cells produce a polysaccharide capsule that is ret...

  2. Application of Toxic Chinese Medicine in Chinese Pharmacopoeia

    Science.gov (United States)

    Zhao, Hui; Feng, Yu; Mao, Mingsan

    2018-01-01

    Objective: Explore the application characteristics of proprietary Chinese medicine prescriptions containing toxic herbs in pharmacopoeia. Methods: In this paper, according to the clinical application of pharmacopoeia proprietary Chinese medicine is divided into table agent, Qushu agent, diarrhea agent, heat agent, Wen Li agent, cough and asthma agents, resuscitation agent, Gutian agent, Fuzheng agent, Anshen agent, hemostatic agent, The traditional Chinese medicine prescription and the clinical application of the Chinese herbal medicine containing the toxic Chinese medicine were analyzed and sorted out., Summed up the compatibility of toxic herbs and application characteristics. Results: Toxic Chinese herbal medicine in the cure of traditional Chinese medicine to play a long-standing role, through the overall thinking, dialectical thinking, and thinking of toxic Chinese medicine in the analysis of Chinese medicine that [2], toxic Chinese medicine in the application of proprietary Chinese medicine can not lack. Conclusion: Pharmacopoeia included proprietary Chinese medicine not only in the clinical treatment of good, but also the application of its toxic traditional Chinese medicine and its understanding of the enrichment of the toxic characteristics of traditional Chinese medicine and treatment-related disease pathology between the points of contact for patients with clinical applications Based on and theoretical guidance of Chinese medicine [3].

  3. Protective effect of the daming capsule on impaired baroreflexes in STZ-induced diabetic rats with hyperlipoidemia

    Directory of Open Access Journals (Sweden)

    Lu Guan-Yi

    2010-12-01

    Full Text Available Abstract Background The Daming capsule (DMC is a traditional Chinese medicine used to treat hyperlipoidemia. Both clinic trials and studies on animal models have demonstrated that DMC is beneficial against diabetic symptoms. Impairment of the baroreflex can cause life-threatening arrhythmias and sudden cardiac death in patients with diabetes mellitus (DM. This study was designed to elucidate the effects of DMC on baroreflexes in streptozocin (STZ-induced diabetic rats with hyperlipoidemia. Methods Wistar rats were randomly divided into three groups: untreated controls, rats pretreated STZ and high lipids (a diabetes model or DM rats, and DM rats treated with DMC. The baroreflex sensitivity was examined during intravenous injection of phenylephrine (PE or sodium nitroprusside (SNP and quantified by the change in heart rate over the change in mean arterial blood pressure (ΔHR/ΔMABP. Morphological remodeling of baroreceptors was analyzed by transmission electron microscopy (TEM. The mRNA levels and expression of GluR2 and a GABAA receptor subunit were measured by quantitative RT-PCR and Western blotting. Results Compared to untreated DM rats, DMC significantly elevated the ratio of ΔHR/ΔMABP by enhancing the compensatory reduction in HR (-ΔHR in response to PE-induced hypertension (+ΔMABP (P P P A receptor expression. Conclusion The Daming capsule partially reversed the parasympathetic baroreflex impairment observed in STZ-induced diabetic rats with hyperlipoidemia. Treatment with DMC also prevented the degeneration of neurons and myelinated axons in the brain stem NAm and reversed the down-regulation of GluR2 mRNA. Rescue of NAm function may contribute to the medicinal properties of DMC in diabetic rats.

  4. TEMPO-oxidized Konjac glucomannan as appliance for the preparation of hard capsules

    NARCIS (Netherlands)

    Chen, Yuying; Zhao, Huiying; Liu, Xianwu; Li, Zusen; Liu, Bin; Wu, Jiande; Shi, Mengxuan; Norde, Willem; Li, Yuan

    2016-01-01

    TEMPO-oxidized Konjac glucomannan (OKGM) was developed as new material for preparing vegetarian hard capsules. OKGM of different degrees of oxidation: DO30%, DO50%, and DO80% were prepared to select optimum DO for capsule formation. FT-IR results proved that the primary alcohol groups on KGM were

  5. Arthroscopic treatment of refractory adhesive capsulitis of the shoulder

    Directory of Open Access Journals (Sweden)

    Marcos Rassi Fernandes

    Full Text Available OBJECTIVE: to evaluate the results of arthroscopic treatment of refractory adhesive capsulitis of the shoulder associated as for improved range of motion after a minimum follow up of six years. METHODS: from August 2002 to December 2004, ten patients with adhesive capsulitis of the shoulder resistant to conservative treatment underwent arthroscopic surgery. One interscalene catheter was placed for postoperative analgesia before the procedure. All were in Phase II, with a minimum follow up of two years. The mean age was 52.9 years (39-66, predominantly female (90%, six on the left shoulder. The time between onset of symptoms and surgical treatment ranged from six to 20 months. Four adhesive capsulitis were found to be primary (40% and six secondary (60%. RESULTS: the preoperative mean of active anterior elevation was 92°, of external rotation was 10.5° of the L5 level internal rotation; the postoperative ones were 149°, 40° and T12 level, respectively. Therefore, the average gain was 57° for the anterior elevation, 29.5° for external rotation in six spinous processes. There was a significant difference in movements' gains between the pre and post-operative periods (p<0.001. By the Constant Score (range of motion, there was an increase of 13.8 (average pre to 32 points (average post. CONCLUSION: the arthroscopic treatment proved effective in refractory adhesive capsulitis of the shoulder resistant to conservative treatment, improving the range of joint movements of patients evaluated after a minimum follow up of six years.

  6. Adhesive capsulitis: role of MR imaging in differential diagnosis

    International Nuclear Information System (INIS)

    Connell, David; Padmanabhan, Ravi; Buchbinder, Rachelle

    2002-01-01

    The purpose of this study was to describe and characterize the MR imaging findings in a group of patients who underwent surgery for adhesive capsulitis. Twenty-four MR imaging studies in 24 consecutive patients with clinical evidence of adhesive capsulitis were performed prior to arthroscopic capsulotomy. There were 17 women and 7 men with a mean age of 53.5 years. Images were scrutinised for changes in the synovium particularly in the rotator interval, around the biceps anchor and axillary pouch. Intravenous gadolinium was given routinely. We also examined a control group of 22 patients who underwent the same MR imaging protocol after referral for rotator cuff pathology. Soft tissue density showing variable enhancement after gadolinium administration was visible in the rotator interval in 22 of 24 studies on MR imaging. Seventeen patients showed soft tissue density partially encasing the biceps anchor. Ten patients showed thickening and gadolinium enhancement of the axillary pouch. Three patients from the study cohort had partial tears of the supraspinatus tendon. All the patients subsequently had surgery which confirmed fibrovascular scar tissue in the rotator interval, around the biceps anchor and a variable degree of synovial inflammation of the glenohumeral capsule. Two patients from a control group with suspected rotator cuff pathology showed abnormal intensity in the rotator interval on MR imaging. Magnetic resonance imaging can identify changes in the shoulder joint that correspond to abnormalities seen at surgery. This may be useful for discriminating adhesive capsulitis from other causes of shoulder pain. (orig.)

  7. Wireless capsule endoscopy in adolescents with familial adenomatous polyposis.

    Science.gov (United States)

    Cavallo, Debora; Ballardini, Giovanni; Ferrari, Andrea; Delconte, Gabriele; Signoroni, Stefano; Sala, Paola; Chiaravalli, Stefano; Massimino, Maura; Bertario, Lucio; Vitellaro, Marco

    2016-01-01

    Guidelines for surveillance in patients with familial adenomatous polyposis (FAP) recommend mutation carriers to undergo periodic colorectal examination starting in the early teens. Performing colonoscopy in children may lead to complications. Wireless capsule endoscopy (WCE) has been introduced recently to evaluate both the upper and lower gastrointestinal tract, and seems suitable as a first screening examination for adolescents. The aim of this study was to evaluate the pros and cons of WCE. This was a retrospective review of a single institution database of adolescent patients with FAP identified through the Hereditary Colorectal Tumor Registry between 2007 and 2013. The main outcomes were identification of upper and lower gastrointestinal tract polyps, tolerance of the examination, and number and size of polyps. Of 46 adolescent patients with FAP, 14 (30.4%) patients carrying adenomatous polyposis coli gene (APC) mutation, 6 male and 8 female, age (median, range) 12 (10-17) years, body mass index 19 (13-24), underwent WCE as first screening examination. The examination was completed in 13 patients (93.3%). Wireless capsule endoscopy identified the duodenal papilla in 4 patients and colonic and rectal polyps in all 13 patients. In 7 patients, fewer than 25 polyps were identified. No complications were recorded related to the use of the video capsule. Wireless capsule endoscopy is feasible and well-tolerated as a first screening examination in adolescent patients. It cannot be used as alternative to the colonoscopy, but could improve compliance with colonoscopy, and increase early adherence to a surveillance program.

  8. Fabrication of hybrid graphene oxide/polyelectrolyte capsules by means of layer-by-layer assembly on erythrocyte cell templates

    Directory of Open Access Journals (Sweden)

    Joseba Irigoyen

    2015-12-01

    Full Text Available A novel and facile method was developed to produce hybrid graphene oxide (GO–polyelectrolyte (PE capsules using erythrocyte cells as templates. The capsules are easily produced through the layer-by-layer technique using alternating polyelectrolyte layers and GO sheets. The amount of GO and therefore its coverage in the resulting capsules can be tuned by adjusting the concentration of the GO dispersion during the assembly. The capsules retain the approximate shape and size of the erythrocyte template after the latter is totally removed by oxidation with NaOCl in water. The PE/GO capsules maintain their integrity and can be placed or located on other surfaces such as in a device. When the capsules are dried in air, they collapse to form a film that is approximately twice the thickness of the capsule membrane. AFM images in the present study suggest a film thickness of approx. 30 nm for the capsules in the collapsed state implying a thickness of approx. 15 nm for the layers in the collapsed capsule membrane. The polyelectrolytes used in the present study were polyallylamine hydrochloride (PAH and polystyrenesulfonate sodium salt (PSS. Capsules where characterized by transmission electron microscopy (TEM, atomic force microscopy (AFM, dynamic light scattering (DLS and Raman microscopy, the constituent layers by zeta potential and GO by TEM, XRD, and Raman and FTIR spectroscopies.

  9. Increased Risk for Adhesive Capsulitis of the Shoulder following Cervical Disc Surgery.

    Science.gov (United States)

    Kang, Jiunn-Horng; Lin, Herng-Ching; Tsai, Ming-Chieh; Chung, Shiu-Dong

    2016-05-27

    Shoulder problems are common in patients with a cervical herniated intervertebral disc (HIVD). This study aimed to explore the incidence and risk of shoulder capsulitis/tendonitis following cervical HIVD surgery. We used data from the Taiwan "Longitudinal Health Insurance Database". We identified all patients who were hospitalized with a diagnosis of displacement of a cervical HIVD and who underwent cervical surgery (n = 1625). We selected 8125 patients who received cervical HIVD conservative therapy only as the comparison group matched with study patients. We individually tracked these sampled patients for 6 months to identify all patients who received a diagnosis of shoulder tendonitis/capsulitis. We found that incidence rates of shoulder tendonitis/capsulitis during the 6-month follow-up period were 3.69 (95% CI: 2.49~5.27) per 100 person-years for the study group and 2.33 (95% CI: 1.89~2.86) per 100 person-years for the comparison group. Cox proportional hazard regressions showed that the adjusted hazard ratio for shoulder tendonitis/capsulitis among patients who underwent cervical disc surgery was 1.66 (95% CI = 1.09~2.53) when compared to comparison group. We concluded that patients who underwent surgery for a cervical HIVD had a significantly higher risk of developing shoulder capsulitis/tendonitis in 6 months follow-up compared to patients who received cervical HIVD conservative therapy only.

  10. Urea-functionalized crystalline capsules for recognition and separation of tetrahedral oxoanions

    Energy Technology Data Exchange (ETDEWEB)

    Custelcean, Radu [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Chemical Sciences Division

    2012-12-21

    We reviewed the persistent ability of tripodal TREN-based tris-urea receptors (TREN = tris(2-aminoethyl)amine) to self-assemble with a variety of oxoanions into dimeric capsules upon crystallization. The capsule crystallization allows for charge-, shape-, and size-selective encapsulation of tetrahedral XO4n-anions (n = 2,3), and provides an effective way to separate these anions from competitive aqueous environments.

  11. Cystic adventitial degeneration: ectopic ganglia from adjacent joint capsules.

    Science.gov (United States)

    Ortmann, J; Widmer, M K; Gretener, S; Do, D D; Willenberg, T; Daliri, A; Baumgartner, I

    2009-11-01

    Cystic adventitial degeneration is a rare non-atherosclerotic cause of peripheral arterial occlusive disease, mainly seen in young men without other evidence of vascular disease. Diagnosis will be established by clinical findings and by ultrasound or angiography and can be treated by excision or enucleation of the affected arterial segment or by percutaneous ultrasound-guided aspiration. However, the etiology of adventitial cysts remains unknown. We report a case of cystic adventitial degeneration showing a connection between the joint capsule and the adventitial cyst, supporting the theory that cystic adventitial degeneration may represent ectopic ganglia from adjacent joint capsules.

  12. Advances in pediatric gastroenterology: introducing video camera capsule endoscopy.

    Science.gov (United States)

    Siaw, Emmanuel O

    2006-04-01

    The video camera capsule endoscope is a gastrointestinal endoscope approved by the U.S. Food and Drug Administration in 2001 for use in diagnosing gastrointestinal disorders in adults. In 2003, the agency approved the device for use in children ages 10 and older, and the endoscope is currently in use at Arkansas Children's Hospital. A capsule camera, lens, battery, transmitter and antenna together record images of the small intestine as the endoscope makes its way through the bowel. The instrument is used with minimal risk to the patient while offering a high degree of accuracy in diagnosing small intestine disorders.

  13. Water Landing Impact of Recovery Space Capsule: A Research Overview

    OpenAIRE

    Nakano, Eiichiro; Uchikawa, Hideaki; Tanno, Hideyuki; Sugimoto, Ryu

    2014-01-01

    For the design of a manned or cargo space capsule, it is important to precisely estimate the Earth landing loads to the crew or cargo, and to limit the loads to within a permissible range. Water landing simulations and scale-model water landing tests with varying conditions for descending velocity, pitch angle, and horizontal velocity during splashdown were conducted to estimate the magnitude of water impact on the recovery space capsule. This paper describes the results of the simulation and...

  14. Status for development of a capsule and instruments for high-temperature irradiation in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Man Soon; Choo, Kee Nam; Lee, Chul Yong; Yang, Seong Woo; Shim, Kyue Taek; Chung, Hwan-Sung [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2012-03-15

    As the reactors planned in the Gen-IV program will be operated at high temperature and under high neutron flux, the requirements for irradiation of materials at high temperature are recently being gradually increased. The irradiation tests of materials in HANARO up to the present have been performed usually at temperatures below 300degC at which the RPV materials of the commercial reactors are being operated. To overcome the restriction for high-temperature use of Al thermal media of the existing standard capsule, a new capsule with double thermal media composed of two kinds of materials such as Al-Ti and Al-graphite was designed and fabricated as a more advanced capsule than the single thermal media capsule. (author)

  15. A fully consistent and conservative vertically adaptive coordinate system for SLIM 3D v0.4 with an application to the thermocline oscillations of Lake Tanganyika

    Science.gov (United States)

    Delandmeter, Philippe; Lambrechts, Jonathan; Legat, Vincent; Vallaeys, Valentin; Naithani, Jaya; Thiery, Wim; Remacle, Jean-François; Deleersnijder, Eric

    2018-03-01

    The discontinuous Galerkin (DG) finite element method is well suited for the modelling, with a relatively small number of elements, of three-dimensional flows exhibiting strong velocity or density gradients. Its performance can be highly enhanced by having recourse to r-adaptivity. Here, a vertical adaptive mesh method is developed for DG finite elements. This method, originally designed for finite difference schemes, is based on the vertical diffusion of the mesh nodes, with the diffusivity controlled by the density jumps at the mesh element interfaces. The mesh vertical movement is determined by means of a conservative arbitrary Lagrangian-Eulerian (ALE) formulation. Though conservativity is naturally achieved, tracer consistency is obtained by a suitable construction of the mesh vertical velocity field, which is defined in such a way that it is fully compatible with the tracer and continuity equations at a discrete level. The vertically adaptive mesh approach is implemented in the three-dimensional version of the geophysical and environmental flow Second-generation Louvain-la-Neuve Ice-ocean Model (SLIM 3D; www.climate.be/slim). Idealised benchmarks, aimed at simulating the oscillations of a sharp thermocline, are dealt with. Then, the relevance of the vertical adaptivity technique is assessed by simulating thermocline oscillations of Lake Tanganyika. The results are compared to measured vertical profiles of temperature, showing similar stratification and outcropping events.

  16. Design Improvements of the Capsule Components and the Handling Tools for an Effective Utilization of the Capsule Assembly Machine

    International Nuclear Information System (INIS)

    Kang, Young Hwan; Kim, Jong Kium; Youm, Ki Un; Yoon, Ki Byung; Choi, Myung Hwan; Kim, Bong Gu

    2006-01-01

    Various in-pile test programs for the development of new fuels and materials are planned for the HANARO reactor. To meet the demands for the required tests in the HANARO reactor, new capsule assembling technology is required in the HANARO reactor. For this reason, a series of analyses and experiments was performed in 2005. For the assembly workability tests of the capsule components, three different kinds of protection tubes and two different shapes of the locking bolt heads were proposed and tested. It was confirmed that the newly designed protection tube and bolts worked quite well without any problems. Since the new structure is quite similar to that of the currently used capsule, it was assumed that an additional vibration tests and seismic analysis would not be needed. Through the stress analysis of the three proposed structures by using ANSYS code, it showed that the maximum displacement and stress intensity for the tube reducer were 1.57mm and 21MPa, respectively. To improve the workability and handling capability of the bolting and clamping tools of stainless steel 304, Al6061/T6 was selected as one of the candidates and thus new tools were manufactured and tested. The assembly test results showed that the new tools were found to be useful for executing key tasks such as a bolting and a clamping and they were much faster than the old tools made of stainless steel, thereby increasing the workability rate and lowering the manufacturing costs

  17. Film Thickness Estimation for the Oil Applied to the Inner Surface of Slim Tubes

    Directory of Open Access Journals (Sweden)

    Jozef Svetlík

    2017-09-01

    Full Text Available The article deals with the approximation of the results of experimental measurement of coating of the inner surface of slim pipes with special oil, using a dispersion oil fraction. The reason for such treatment of the inner surface of the tubes is the anti-corrosion protection or various other requirements. The oil manufacturer prescribes the minimum required layer to guarantee the anti-corrosion protection parameters. Therefore, it is advisable to know the most exact coating parameters for different pipe diameters. The measured results give us an assumption of how much oil is sufficient to coat the inside of a pipe. The main idea lies in the correct estimation of coefficients in the three-parameter exponential dependence. For the initial estimates, Nelder–Mead’s minimization method was used. The condition for meeting the lower estimate of the minimum thickness of the oil layer was determined. Following graphic processing of minimization of individual pipe diameters, in some cases, the coefficients were adjusted manually. The result is that the oil thickness depends on the distance of the investigated point from the beginning of the tube, or on the point of entry of the dispersion oil fraction.

  18. Efficacy of Qianggan capsule in treatment of non-alcoholic fatty liver disease complicated with hyperlipidemia

    Directory of Open Access Journals (Sweden)

    Zhi-Jun He

    2016-07-01

    Full Text Available Objective: To observe the clinical effects of Qianggan capsule and silibinin capsule in the treatment of non-alcoholic fatty liver disease complicated with hyperlipidemia. Methods: A total of 112 patients with non-alcoholic fatty liver disease were included in the study and divided into the control group (n=50 and the observation group (n=62. The patients in the control group were given silibinin capsule, while the patients in the observation group were given Qianggan capsule. The patients in the two groups were treated for 24 weeks. The liver/ spleen CT was performed before and after treatment. BMI was measured. The liver function, serum lipid, and leptin were detected. Results: TG, LDL-C, BMI, and liver/spleen CT ratio in the observation group were significantly reduced when compared with the control group. The levels of HDL-C and adiponectin in the observation group were significantly elevated when compared with the control group. The differences of ALT, GGT, and AST after treatment between the two groups were not statistically significant. Conclusions: Qianggan capsule and silibinin capsule has an accurate efficacy and high safety in the treatment of non-alcoholic fatty liver disease complicated with hyperlipidemia.

  19. Application methods of infrared thermal images in the health care field of traditional Chinese medicine

    Science.gov (United States)

    Li, Ziru; Zhang, Xusheng

    2008-12-01

    Infrared thermal imaging (ITI) is the potential imaging technique for the health care field of traditional Chinese medicine (TCM). Successful application demands obeying the characteristics and regularity of the ITI of human body and designing rigorous trials. First, the influence of time must be taken into account as the ITI of human body varies with time markedly. Second, relative magnitude is preferred to be the index of the image features. Third, scatter diagrams and the method of least square could present important information for evaluating the health care effect. A double-blind placebo-controlled randomized trial was undertaken to study the influences of Shengsheng capsule, one of the TCM health food with immunity adjustment function, on the ITI of human body. The results showed that the effect of Shengsheng capsule to people with weak constitution or in the period of being weak could be reflected objectively by ITI. The relative efficacy rate was 81.3% for the trial group and 30.0% for the control group, there was significant difference between the two groups (P=0.003). So the sensitivity and objectivity of ITI are of great importance to the health care field of TCM.

  20. Thallium(I) sorption using Prussian blue immobilized in alginate capsules.

    Science.gov (United States)

    Vincent, Thierry; Taulemesse, Jean-Marie; Dauvergne, Agnès; Chanut, Thomas; Testa, Flaviano; Guibal, Eric

    2014-01-01

    Prussian blue (PB) was immobilized in alginate capsules. The composite sorbent was used for the recovery of Tl(I) ions from slightly acidic solutions: optimum pH being close to 4. The sorption isotherm can be described by the bi-site Langmuir sorption isotherm. This means that the metal ion can be bound through two different sorption sites: one having a strong affinity for Tl(I) (probably PB), the other having a lower affinity (probably the encapsulating material). The kinetics are described by either the pseudo-second order rate equation or the Crank's equation (resistance to intraparticle diffusion). The ionic strength (increased by addition of NaCl, KCl or CaCl₂) slightly decreased sorption capacity. The SEM-EDX analysis of PB-alginate capsules (before and after Tl(I) sorption) shows that the PB is homogeneously distributed in the capsules and that all reactive groups remain available for metal binding. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Reduced anterior internal capsule white matter integrity in primary insomnia.

    Science.gov (United States)

    Spiegelhalder, Kai; Regen, Wolfram; Prem, Martin; Baglioni, Chiara; Nissen, Christoph; Feige, Bernd; Schnell, Susanne; Kiselev, Valerij G; Hennig, Jürgen; Riemann, Dieter

    2014-07-01

    Chronic insomnia is one of the most prevalent central nervous system diseases, however, its neurobiology is poorly understood. Up to now, nothing is known about the integrity of white matter tracts in insomnia patients. In this study, diffusion tensor imaging (DTI) was used in a well-characterized sample of primary insomnia (PI) patients and good sleeper controls to fill this void. Voxelwise between-group comparisons of fractional anisotropy (FA) were performed in 24 PI patients (10 males; 14 females; 42.7 ± 14.5 years) and 35 healthy good sleepers (15 males; 20 females; 40.1 ± 9.1 years) with age and sex as covariates. PI patients showed reduced FA values within the right anterior internal capsule and a trend for reduced FA values in the left anterior internal capsule. The results suggest that insomnia is associated with a reduced integrity of white matter tracts in the anterior internal capsule indicating that disturbed fronto-subcortical connectivity may be a cause or consequence of the disorder.

  2. Development of a High Efficiency Dry Powder Inhaler: Effects of Capsule Chamber Design and Inhaler Surface Modifications

    Science.gov (United States)

    Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth

    2013-01-01

    Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD 90%, and ED > 80%. PMID:23949304

  3. Development of a high efficiency dry powder inhaler: effects of capsule chamber design and inhaler surface modifications.

    Science.gov (United States)

    Behara, Srinivas R B; Farkas, Dale R; Hindle, Michael; Longest, P Worth

    2014-02-01

    The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD  90%, and ED > 80%.

  4. 21 CFR 189.301 - Tin-coated lead foil capsules for wine bottles.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Tin-coated lead foil capsules for wine bottles. 189... SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) SUBSTANCES PROHIBITED FROM USE IN HUMAN FOOD... lead foil capsules for wine bottles. (a) Tin-coated lead foil is composed of a lead foil coated on one...

  5. [Effect analysis on Deanxit combined with Shuganjieyu capsule in the treatment of refractory gastroesophageal reflux disease].

    Science.gov (United States)

    Yang, X Y; Guo, C Y; Zhang, X; Zhong, Y Q; Tian, C

    2017-11-28

    Objective: To investigate the curative effect of Deanxit combined with Shuganjieyu capsule on the treatment of refractory gastroesophageal reflux disease. Methods: A total of 125 patients with refractory gastroesophageal reflux disease who had failed in standard lansolazole capsule treatment in the Department of Gastroenterology, First People's Hospital of Neijiang were selected. According to the symptom scores and mood scores of gastroesophageal reflux disease, patients were randomly and double-blindly divided into five groups. Group A(Lansoprazole Capsules + Mosapride Citrate + Deanxit), B(Lansoprazole Capsules + Mosapride Citrate + Shuganjieyu capsule), C(Lansoprazole Capsules + Mosapride Citrate+ Deanxit + Shuganjieyu capsule) and D(Deanxit) groups are study groups, the other was control group (Lansoprazole Capsules + Mosapride Citrate). The scores of symptoms and mood were compared after 4 weeks and 8 weeks of treatment. Results: The clinical symptoms score, HAMA and HAMD scores were significantly lower in the all study groups in comparison to the control group after 4 weeks and 8 weeks therapy. The clinical symptoms score, HAMA and HAMD scores in group C were significantly lower than those in group A and B ( P 0.05). The HAMA and HAMD scores of group D were significantly higher than those of group A, B, C and control group, and the differences were statistically significant ( P gastroesophageal reflux disease, which can effectively improve the total treatment efficiency, reduce the symptom scores and mood scores of gastroesophageal reflux disease patients.

  6. Out-pile test of non-instrumented capsule for the advanced PWR fuel pellets in HANARO irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, D. H.; Lee, C. B.; Oh, D. S.; Bang, J. K.; Kim, Y. M.; Yang, Y. S.; Jeong, Y. H.; Jeon, H. K.; Ryu, J. S. [KAERI, Taejon (Korea, Republic of)

    2002-05-01

    Non-instrumental capsule were designed and fabricated to irradiate the advanced pellet developed for the high burn-up LWR fuel in the HANARO in-pile capsule. This capsule was out-pie tested at Cold Test Loop-I in KAERI. From the pressure drop test results, it is noted that the flow velocity across the non-instrumented capsule of advanced PWR fuel pellet corresponding to the pressure drop of 200 kPa is measured to be about 7.45 kg/sec. Vibration frequency for the capsule ranges from 13.0 to 32.3 Hz. RMS displacement for non-instrumented capsule of advanced PWR fuel pellet is less than 11.6 {mu}m, and the maximum displacement is less that 30.5 {mu}m. The flow rate for endurance test were 8.19 kg/s, which was 110% of 7.45 kg/s. And the endurance test was carried out for 100 days and 17 hours. The test results found not to the wear satisfied to the limits of pressure drop, flow rate, vibration and wear in the non-instrumented capsule.

  7. Java brucea and Chinese herbal medicine for the treatment of cholesterol granuloma in the suprasellar and sellar regions: A case report and literature review.

    Science.gov (United States)

    Sun, Zhe; Cao, Yang; Zhai, Lin-Zhu

    2017-02-01

    A cholesterol granuloma (CG) is usually found in the middle ear, papilla, orbits, petrous apex, and choroid plexus, but is highly uncommon in the skull. In spite of benign clinicopathological lesions, bone erosion can be seen occasionally in the patient with CG. The optimal treatment strategy is radical surgery, but complete excision is usually impossible due to anatomical restrictions and a risk of injury to the key structures located nearby. Here, we report a patient with CGs in the suprasellar and sellar regions who was successfully treated with Java brucea and Chinese herbal medicine. A 31-year-old man presenting with progressive decreased vision in both eyes was analyzed. A skull magnetic resonance imaging (MRI) scan showed a low-density tumor in the uprasellar and sellar regions and histopathological examination revealed a CG. The patient was referred the surgery and radiotherapy. In the meantime, brucea soft capsules and herbal medicine combined were administered to him. The related clinical symptoms and signs resolved significantly after several months, as his therapy progressed. The patient showed no sign of recurrence during the treatment period. Furthermore, he was still alive and disease-free at 37 months of follow-up visit. Overall, brucea soft capsules and a Chinese herbal formula treatment combined could be beneficial in improving the patient's quality of life with CG in the skull.

  8. As(III) oxidation by MnO{sub 2} coated PEEK-WC nanostructured capsules

    Energy Technology Data Exchange (ETDEWEB)

    Criscuoli, Alessandra, E-mail: a.criscuoli@itm.cnr.it [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Majumdar, Swachchha [Central Glass and Ceramic Research Institute, 196, Raja S. C. Mullick Rd., 700032 Kolkata (India); Figoli, Alberto, E-mail: a.figoli@itm.cnr.it [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Sahoo, Ganesh C. [Central Glass and Ceramic Research Institute, 196, Raja S. C. Mullick Rd., 700032 Kolkata (India); Bafaro, Patrizia [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Department of Chemical Engineering and Materials, University of Calabria, Via P. Bucci Cubo 42/A, 87030 Rende (CS) (Italy); Bandyopadhyay, Sibdas [Central Glass and Ceramic Research Institute, 196, Raja S. C. Mullick Rd., 700032 Kolkata (India); Drioli, Enrico [Institute on Membrane Technology, ITM-CNR, Via P. Bucci Cubo 17/C, 87030 Rende (CS) (Italy); Department of Chemical Engineering and Materials, University of Calabria, Via P. Bucci Cubo 42/A, 87030 Rende (CS) (Italy)

    2012-04-15

    Highlights: Black-Right-Pointing-Pointer Successful preparation of PEEK-WC nanostructured capsules coated by MnO{sub 2}. Black-Right-Pointing-Pointer Preliminary tests of As(III) oxidation carried out in batch. Black-Right-Pointing-Pointer Complete oxidation obtained for feed concentrations of 0.1 and 0.3 ppm. - Abstract: PEEK-WC nanostructured capsules were prepared by the phase inversion technique and used as support for the coating of a manganese dioxide layer. The coating was done by a chemical treatment of the capsules followed by a thermal one. The presence of the MnO{sub 2} layer was confirmed by scanning electron microscopy (SEM), back scattering electron (BSE), energy dispersive X-ray (EDX) and X-ray diffraction (XRD) analysis. The produced capsules were, then, tested for As(III) oxidation in batch. The experiments consisted in treating 165 ml of As(III) solution with 1 g of coated capsules at fixed temperature (15 Degree-Sign C) and pH (5.7-5.8). In particular, the efficiency of the system was investigated for different As(III) concentrations (0.1, 0.3, 0.7 and 1 ppm). For feeds at lower As(III) content (0.1-0.3 ppm), tests lasted for 8 h, while prolonged runs (up to 48 h) were carried out on more concentrated solutions (0.7 and 1 ppm). The produced capsules were able to oxidize As(III) into As(V) leading to complete conversion after 3 and 4 h for feed concentrations of 0.1 and 0.3 ppm, respectively.

  9. Programmed temperature control of capsule in irradiation test with personal computer at JMTR

    International Nuclear Information System (INIS)

    Saito, H.; Uramoto, T.; Fukushima, M.; Obata, M.; Suzuki, S.; Nakazaki, C.; Tanaka, I.

    1992-01-01

    The capsule irradiation facility is one of various equipments employed at the Japan Materials Testing Reactor (JMTR). The capsule facility has been used in irradiation tests of both nuclear fuels and materials. The capsule to be irradiated consists of the specimen, the outer tube and inner tube with a annular space between them. The temperature of the specimen is controlled by varying the degree of pressure (below the atmospheric pressure) of He gas in the annular space (vacuum-controlled). Beside this, in another system the temperature of the specimen is controlled with electric heaters mounted around the specimen (heater-controlled). The use of personal computer in the capsule facility has led to the development of a versatile temperature control system at the JMTR. Features of this newly-developed temperature control system lie in the following: the temperature control mode for a operation period can be preset prior to the operation; and the vacuum-controlled irradiation facility can be used in cooperation with the heater-controlled. The introduction of personal computer has brought in automatic heat-up and cool-down operations of the capsule, setting aside the hand-operated jobs which had been conducted by the operators. As a result of this, the various requirements seeking a higher accuracy and efficiency in the irradiation can be met by fully exploiting the capabilities incorporated into the facility which allow the cyclic or delicate changes in the temperature. This paper deals with a capsule temperature control system with personal computer. (author)

  10. Preparation of sustained release capsules by electrostatic dry powder coating, using traditional dip coating as reference.

    Science.gov (United States)

    Yang, Yan; Shen, Lian; Yuan, Feng; Fu, Hui; Shan, Weiguang

    2018-05-30

    Lately, a great deal of attention is being paid to capsule coating, since the coat protects active pharmaceutical ingredients (APIs) from damage, as is in the case of tablet and pellet. However, moisture and heat sensitivity of gelatin shells make it challenging to coat capsules using the conventional aqueous coating techniques. In an effort to overcome this challenge, the present study aims to coat capsules using two different coating techniques: electrostatic dry powder coating (EDPC) and dip coating (DC). Both capsule coatings and free films were prepared by these two coating techniques, and the effects of coating formulations and processing conditions on the film quality were investigated. The corresponding drug in vitro release and mechanisms were characterized and compared. The results of dissolution tests demonstrated that the drug release behavior of both EDPC and DC coated capsules could be optimized to a sustained release of 24 h, following the Fick's diffusion law. The results of this study suggest that EDPC method is better than DC method for coating capsules, with respect to the higher production efficiency and better stability, indicating that this dry coating technology has promised in gelatin capsule coating applications. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Investigation of special capsule technologies for material in-pile irradiation test and development plan in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Cho, M. S.; Son, J. M.; Kim, D. S.; Park, S. J.; Cho, Y. G.; Seo, C. K.; Kang, Y. H. [KAERI, Taejon (Korea, Republic of)

    2002-10-01

    In-pile test for several materials such as Zr alloy, stainless steel, Cr-Ni steel etc. which are used as structural material of the advanced reactor and KNGR(Korea Next Generation Reactor) like SMART, is necessary to produce the design data for developing new reactor materials. Advanced countries like USA, Europe and Japan etc. are not only performing the simple irradiation test for materials, but developing many kinds of special capsule to perform in-pile test having special purpose. For the special test items of fuel rod, fission products, total heat generation, swelling, deformation, sweep gas, temperature ramping and BOCA etc. are being actively concerned. There are capsules measuring creep, fatigue, crack growth, and controlling fluence etc. for special irradiation test of materials. In addition, the advanced countries are developing several instrument technologies suitable for the special capsules. In HANARO, non-instrumented, instrumented material capsules and non-instrumented fuel capsule have been developed and they have been utilized in the irradiation test for users, and creep capsule loading single specimen was made and is planned to test in the reactor soon. For some forthcoming years, special capsules not only measuring creep deformation with multi-specimens, fatigue, controlling fluence but crack propagation and gas sweep considering the requirements of users will be developed in HANARO.

  12. A performance test of a capsule for a material irradiation in the OR holes of HANARO

    International Nuclear Information System (INIS)

    Cho, M. S.; Choo, K. N.; Shin, Y. T.; Sohn, J. M.; Park, S. J.; Kang, Y. H.; Kim, B. G.

    2008-01-01

    A test for a pressure drop and a vibration was performed to develop a material capsule for an irradiation at the OR hole in HANARO. It was analyzed before the test that a diameter of a material capsule for the OR holes should be more than 49mm by an evaluation of a flow rate and pressure drop in theory. According to this estimation, 3 kinds of mock-up capsules with a diameter of 52, 54, 56 mm were made and applied to a pressure drop test. As a result of the pressure drop test, the requirement for a pressure and a flow rate in HANARO was confirmed to be satisfied for the 3 kinds of diameters. The capsules with diameters of 54, 56mm were applied to a vibration test by taking into consideration a receptive capacity of the specimens. The capsule with a diameter of 56mm satisfied the requirement for an allowable limit of the vibration acceleration applied in HANARO. The heat transfer coefficient and the temperature on the surface of a capsule were estimated. As the temperature on the surface of the capsule was calculated to be 43.7 .deg. C, the ONB condition in HANARO was satisfied

  13. In vivo osteogenic differentiation of stem cells inside compartmentalized capsules loaded with co-cultured endothelial cells.

    Science.gov (United States)

    Correia, Clara R; Santos, Tírcia C; Pirraco, Rogério P; Cerqueira, Mariana T; Marques, Alexandra P; Reis, Rui L; Mano, João F

    2017-04-15

    Capsules coated with polyelectrolytes and co-encapsulating adipose stem (ASCs) and endothelial (ECs) cells with surface modified microparticles are developed. Microparticles and cells are freely dispersed in a liquified core, responsible to maximize the diffusion of essential molecules and allowing the geometrical freedom for the autonomous three-dimensional (3D) organization of cells. While the membrane wraps all the instructive cargo elements within a single structure, the microparticles provide a solid 3D substrate for the encapsulated cells. Our hypothesis is that inside this isolated biomimetic 3D environment, ECs would lead ASCs to differentiate into the osteogenic lineage to ultimately generate a mineralized tissue in vivo. For that, capsules encapsulating only ASCs (MONO capsules) or co-cultured with ECs (CO capsules) are subcutaneously implanted in nude mice up to 6weeks. Capsules implanted immediately after production or after 21days of in vitro osteogenic stimulation are tested. The most valuable outcome of the present study is the mineralized tissue in CO capsules without in vitro pre-differentiation, with similar levels compared to the pre-stimulated capsules in vitro. We believe that the proposed bioencapsulation strategy is a potent self-regulated system, which might find great applicability in bone tissue engineering. The diffusion efficiency of essential molecules for cell survival is a main issue in cell encapsulation. Former studies reported the superior biological outcome of encapsulated cells within liquified systems. However, most cells used in TE are anchorage-dependent, requiring a solid substrate to perform main cellular processes. We hypothesized that liquified capsules encapsulating microparticles are a promising attempt. Inspired by the multiphenotypic cellular environment of bone, we combine the concept of liquified capsules with co-cultures of stem and endothelial cells. After implantation, results show that co-cultured capsules

  14. Model of the humanoid body for self collision detection based on elliptical capsules

    CSIR Research Space (South Africa)

    Dube, C

    2011-12-01

    Full Text Available . The humanoid body is modeled using elliptical capsules, while the moving segments, i.e. arms and legs, of the humanoid are modeled using circular capsules. This collision detection model provides a good fit to the humanoid body shape while being simple...

  15. Power measurement in the boiling capsules in R2 using delayed neutron detector

    International Nuclear Information System (INIS)

    Roennberg, G.

    1979-03-01

    LWR fuel testing is performed in the R2 reactor by irradiation in both loops and so-called boiling capsules. The loops have forced cooling, and the power can be measured calorimetrically by conventional instrumentation. The boiling capsules have convection cooling, and it has therefore been necessary to develop a special technique for power measurement, the delayed neutron detector (DND). The DND is a pneumatic rabbit system, which activates small uranium samples in the boiling capsules and counts the delayed neutrons for determination of the fission rate. This report describes the equipment used, the procedure of measurement, and the method of evaluation. (atuhor)

  16. [A wireless power transmission system for capsule endoscope].

    Science.gov (United States)

    Xin, Wenhui; Yan, Guozheng; Wang, Wenxing

    2010-06-01

    In order to deliver power to the capsule endoscope, whose position and orientation are always changing when traveling along the alimentary tract, a wireless power transmission system based on electromagnetic coupling was proposed. The system is composed of Helmholtz transmitting coil and three-dimensional receiving coil. Helmholtz coil outside the body generates a uniform magnetic field covering the whole alimentary tract; three-dimensional coil inside retrieves stable power regardless of its position and orientation. The transmitter and receiver were designed and implemented, and the experiments validated the feasibility of the system. The results show that at least 320 mW of usable power can be transmitted to capsule endoscope when its position and orientation are changing at random and the transmitting power is 25W.

  17. Capsule enteroscopy and radiology of the small intestine

    Energy Technology Data Exchange (ETDEWEB)

    Fork, Frans-Thomas [Malmoe University Hospital, Department of Diagnostic Radiology, Malmoe (Sweden); Aabakken, Lars [Rikshospitalet University Hospital, Department of Gastroenterology, Oslo (Norway)

    2007-12-15

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  18. Postirradiation thermal analysis of capsule P13T

    International Nuclear Information System (INIS)

    Ketterer, J.W.

    1978-12-01

    In determining fuel rod temperature histories for the P13T capsule, a technique which combined measured temperature and dimensional data, TAC-2D computer modeling, and a calculational procedure was employed. TAC-2D models were constructed for each of the capsule's four fuel bodies and temperature matching runs were made at five time points of the irradiation history. The agreement between TAC-calculated and measured temperatures was good; at all times the TAC-calculated temperatures were within 20 0 C of the Chromel-Alumel (C/A) measurements and 40 0 C of the corrected tungsten-rhenium (W/Re) temperatures. Thermocouple decalibration was treated in detail and corrected temperatures for all W/Re thermocouples were calculated over the irradiation period

  19. Capsule enteroscopy and radiology of the small intestine

    International Nuclear Information System (INIS)

    Fork, Frans-Thomas; Aabakken, Lars

    2007-01-01

    In a very few years, the video capsule for small bowel enteroscopy has gained widespread clinical acceptance. It is readily ingested, disposable, and allows for a complete, low-invasive endoscopic examination of the entire mucosa of the small bowel. It is a patient-friendly method and a first-line procedure in the difficult evaluation of obscure gastrointestinal bleeding. It has the highest proven figure of diagnostic sensitivity for detecting lesions of the mucosa, irrespective of aetiology. The limitations of capsule endoscopy include difficulty in localising mucosal lesions anatomically and its restricted use in patients with dysphagia, strictures or motor dysfunction. Strictures, transmural and extra-mural lesions in patients with small bowel Crohn's disease are evaluated by MRI- enterography and CT-enterography. (orig.)

  20. Simulations of laser imprint for Nova experiments and for ignition capsules. Revision 1

    International Nuclear Information System (INIS)

    Weber, S.V.; Glendinning, S.G.; Kalantar, D.H.; Key, M.H.; Remington, B.A.; Rothenberg, J.L.; Wolfrum, E.; Verdon, C.P.; Knauer, J.P.

    1996-12-01

    In direct drive ICF, nonuniformities in laser illumination seed ripples at the ablation front in a process called ''imprint''. These nonuniformities grow during the capsule implosion and, if initially large enough, can penetrate the capsule shell, impede ignition, or degrade burn. Imprint has been simulated for recent experiments performed on the Nova laser at LLNL examining a variety of beam smoothing conditions. Most used laser intensities similar to the early part of an ignition capsule pulse shape, 1 ≅ 10 13 W/cm 2 . The simulations matched most of the measurements of imprint modulation. The effect of imprint upon National Ignition Facility (NIF) direct drive ignition capsules has also been simulated. Imprint is predicted to give modulation comparable to an intrinsic surface finish of ∼10 nm RMS. Modulation growth was examined using the Haan [Phys. Rev. A 39, 5812 (1989)] model, with linear growth factors as a function of spherical harmonic mode number obtained from an analytic dispersion relation. Ablation front amplitudes are predicted to become substantially nonlinear, so that saturation corrections are large. Direct numerical simulations of two-dimensional multimode growth were also performed. The capsule shell is predicted to remain intact, which gives a basis for believing that ignition can be achieved. 27 refs., 10 figs

  1. Non-instrumented capsule design of HANARO irradiation test for the high burn-up large grain UO2 pellets

    International Nuclear Information System (INIS)

    Kim, D. H.; Lee, C. B.; Oh, D. S.

    2001-01-01

    Non-instrumented capsule was designed to irradiate the large grain UO 2 pellet developed for the high burn-up LWR fuel in the HANARO in-pile capsule. UO 2 pelletes will be irradiated up to the burn-up higher than 70 MWD/kgU in HANARO. To irradiate the UO 2 pellets up to the burn-up 70 MWD/kgU, need the time about 60 months and ensure the integrity of non-instrumented capsule for 30 months until replace the new capsule. In addition, to satisfy the safety criteria of HANARO such as prevention of ONB(Onset of Nucleate Boiling), fuel melting and wear damage of the capsule during the long term irradiation, design of the non-instrumented capsule was optimized

  2. High temperature radioisotope capsule

    International Nuclear Information System (INIS)

    Bradshaw, G.B.

    1976-01-01

    A high temperature radioisotope capsule made up of three concentric cylinders, with the isotope fuel located within the innermost cylinder is described. The innermost cylinder has hemispherical ends and is constructed of a tantalum alloy. The intermediate cylinder is made of a molybdenum alloy and is capable of withstanding the pressure generated by the alpha particle decay of the fuel. The outer cylinder is made of a platinum alloy of high resistance to corrosion. A gas separates the innermost cylinder from the intermediate cylinder and the intermediate cylinder from the outer cylinder

  3. Out-pile test of the capsule with cone shape bottom structures

    Energy Technology Data Exchange (ETDEWEB)

    Choi, M. H.; Kang, Y. H.; Cho, M. S.; Choo, K. N.; Kim, B. G.; Son, J. M.; Park, S. J.; Shin, Y. T.; Oh, J. M

    2004-01-01

    The design modification of bottom guide structures for the instrumented capsule which is used for the irradiation test in the research reactor, HANARO is done because of the cutting trouble of the bottom guide arm's pin. The previous structure of the 3-pin arm shape is changed into one body of the cone shape. The specimens of the bottom end cap ring with three different sizes ({phi}68mm, {phi}70mm, {phi}72mm) are designed and manufactured. The out-pile test for the capsule with previous 3-pin arm and new three bottom structures of the cone shape is performed using the one-channel flow test facilities. In order to estimate the compatibility with HANARO, the structural stability and integrity of the capsule, the out-pile test such as a loading/unloading test, a pressure drop test, a thermal performance test, a displacement measurement due to a vibration and an endurance test etc. is conducted, and the outer diameter of the bottom end cap ring to meet the HANARO requirements is selected. From out-pile test results the capsule with cone shape bottom structures is evaluated as to have the structural stability and the benefit from the fluid's flow respect. Also the size satisfied various requirements among three kinds of bottom end cap rings is 70mm in diameter. It is expected that the new bottom structures of the cone shape with 70mm in diameter will be applicable to all material and special capsules which will be designed and manufactured for the purpose of irradiation tests in the future.

  4. Ingestible Wireless Capsule Technology: A Review of Development and Future Indication

    Directory of Open Access Journals (Sweden)

    M. R. Basar

    2012-01-01

    Full Text Available Ingestible wireless capsule endoscopy (WCE is the one and only painless, effective, novel, diagnostic technology for inspecting the entire gastrointestinal (GI tract for various diseases, such as obscure gastrointestinal bleeding (OGIB, tumors, cancer, Crohn’s disease, and celiac disease. Since the development of this technology, several companies have made remarkable improvements in their clinical products, but there are still some limitations that relate to the use of conventional wired endoscopy. Some of the major limitations that currently impede its wider application include its inability to repeat the view of critical areas, working time constraints, and poor image resolution. Many research groups currently are working on ways to solve these limitations. Presently, developing the ability to control the movement of the capsule, increasing its image transmission speed, and obtaining high-quality images are the main issues in the research area. A complex capsule with some therapeutic tools for the treatment of diseases of the GI tract also is at the beginning of development for the next generation of an active medical robot. In this paper, we report the status of several activities related to WCE, including improvement of capsule technology, research progress, technical challenges, and key indicators concerning the next-generation, active, medical robot.

  5. Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive

    International Nuclear Information System (INIS)

    Gu, Jianfa; Dai, Zhensheng; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping

    2016-01-01

    The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.

  6. Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive

    Science.gov (United States)

    Gu, Jianfa; Dai, Zhensheng; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping

    2016-08-01

    The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.

  7. Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Jianfa, E-mail: gu-jianfa@iapcm.ac.cn; Dai, Zhensheng, E-mail: dai-zhensheng@iapcm.ac.cn; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping [Institute of Applied Physics and Computational Mathematics, Beijing 100088 (China)

    2016-08-15

    The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.

  8. Use of atomic force microscopy and transmission electron microscopy for correlative studies of bacterial capsules.

    Science.gov (United States)

    Stukalov, Oleg; Korenevsky, Anton; Beveridge, Terry J; Dutcher, John R

    2008-09-01

    Bacteria can possess an outermost assembly of polysaccharide molecules, a capsule, which is attached to their cell wall. We have used two complementary, high-resolution microscopy techniques, atomic force microscopy (AFM) and transmission electron microscopy (TEM), to study bacterial capsules of four different gram-negative bacterial strains: Escherichia coli K30, Pseudomonas aeruginosa FRD1, Shewanella oneidensis MR-4, and Geobacter sulfurreducens PCA. TEM analysis of bacterial cells using different preparative techniques (whole-cell mounts, conventional embeddings, and freeze-substitution) revealed capsules for some but not all of the strains. In contrast, the use of AFM allowed the unambiguous identification of the presence of capsules on all strains used in the present study, including those that were shown by TEM to be not encapsulated. In addition, the use of AFM phase imaging allowed the visualization of the bacterial cell within the capsule, with a depth sensitivity that decreased with increasing tapping frequency.

  9. 3D magnetic-resonance-coupling (MRC) localization of wireless capsule endoscopy

    DEFF Research Database (Denmark)

    Xia, Yongming; Zhang, Lihui; Lu, Kaiyuan

    2016-01-01

    ) technique, which has been widely developed for efficient wireless power transfer, is introduced. It is proposed that the distance dependent signal strength in a MRC system can be beneficially used for 3D localization. The new 3D-MRC localization system consists of three orthogonal emitting coils which......Wireless Capsule Endoscope (WCE) enables developing actively controlled capsule for potential complex surgeries, imaging, and new medicine tests. These tasks of WCE need safe, efficient, and precise 3D localization techniques. In this paper, a new application of the magnetic resonance coupling (MRC...... are powered by a battery in the capsule, and three pairs of orthogonal receiving coils which are placed outside human body. The distances between the WCE and the receiving coils can be estimated with good accuracy by studying the signal strengths in individual receiving coils. The proposed new 3D...

  10. ALARA implementation in 131I therapeutic capsule production facility

    International Nuclear Information System (INIS)

    Kumawat, Lalit; Swaminathan, N.; Sudheer, T.S.; Sachdev, S.S.; Arora, S.S.; Vairalkar, K.G.

    2005-01-01

    Sodium iodide 131 I solution had been invariably administered to patients for both diagnosis and therapy of thyrotoxicosis. The undue exposure to non-target organs has been over come by introducing NaI ( 131 I) in a gelatin capsule. BRIT has set up experimental facility for the preparation and the production volume has augmented into four fold due to increase in demand and the same facility is being used to cater the need. However, the adequately shielded facility (fume hood) used for (manual) dispensing activity in capsules, capsules and product vial capping, transfer of the vials into lead pots and activity measurement of each vial has resulted in significant increase in the personnel exposure. The sources had been identified and efforts were made to reduce the exposure in these operations. An annular shield was introduced around the dispenser, resulted in the reduction of radiation field at wrist level by a factor of three. Introduction of shielded automated dispenser and usage of longer tools for transfer and capping of vials has effected in two times reduction of collective wrist dose. Currently, the relocated capping station two meters away from the source certainly will bring down further exposure. (author)

  11. Application of the UV laser printing technique to soft gelatin capsules containing titanium dioxide in the shells.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru

    2012-03-01

    The purpose of this study was to examine application of ultraviolet (UV) laser irradiation to printing soft gelatin capsules containing titanium dioxide (TiO(2)) in the shells and to study effect of UV laser power on the color strength of printing on the soft gelatin capsules. Size 6 Oval type soft gelatin capsules of which shells contained 0.685% TiO(2) and 0.005% ferric dioxide were used in this study. The capsules were irradiated pulsed UV laser at a wavelength 355 nm. The color strength of the printed capsules was determined by a spectrophotometer as total color difference (dE). The soft gelatin capsules which contained TiO(2) in the shells could be printed gray by the laser. Many black particles, which were associated with the printing, were formed at the colored parts of the shells. It was found that there were two inflection points in relationship between output laser energy of a pulse and dE. Below the lower point, the capsules were not printed. From the lower point to the upper point, the capsules were printed gray and total color difference of the printing increased linearly in proportion with the output laser energy. Beyond the upper point, total color difference showed saturation because of micro-bubbles formation at the laser irradiated spot. Soft gelatin capsules containing TiO(2) in the shells could be performed stable printing using the UV laser printing technique. Color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  12. Deformation of a Capsule in a Power-Law Shear Flow

    Directory of Open Access Journals (Sweden)

    Fang-Bao Tian

    2016-01-01

    Full Text Available An immersed boundary-lattice Boltzmann method is developed for fluid-structure interactions involving non-Newtonian fluids (e.g., power-law fluid. In this method, the flexible structure (e.g., capsule dynamics and the fluid dynamics are coupled by using the immersed boundary method. The incompressible viscous power-law fluid motion is obtained by solving the lattice Boltzmann equation. The non-Newtonian rheology is achieved by using a shear rate-dependant relaxation time in the lattice Boltzmann method. The non-Newtonian flow solver is then validated by considering a power-law flow in a straight channel which is one of the benchmark problems to validate an in-house solver. The numerical results present a good agreement with the analytical solutions for various values of power-law index. Finally, we apply this method to study the deformation of a capsule in a power-law shear flow by varying the Reynolds number from 0.025 to 0.1, dimensionless shear rate from 0.004 to 0.1, and power-law index from 0.2 to 1.8. It is found that the deformation of the capsule increases with the power-law index for different Reynolds numbers and nondimensional shear rates. In addition, the Reynolds number does not have significant effect on the capsule deformation in the flow regime considered. Moreover, the power-law index effect is stronger for larger dimensionless shear rate compared to smaller values.

  13. Effects of Tang Mai Kang Capsule on Angioneurotic Lesions in Alloxan-Induced Diabetic Mice

    Institute of Scientific and Technical Information of China (English)

    李华; 王军; 高丽君; 郭永成

    2004-01-01

    The effects of Tang Mai Kang Capsule (糖脉康胶囊) on blood sugar level, gangrene of the tail-tip, pain threshold and learning and memory abilities were investigated in alloxan-induced diabetic mice. The results showed that Tang Mai Kang Capsule could significantly decrease blood sugar level and incidence rate of gangrene of the tail-tip, increase pain threshold, and strengthen learning and memory abilities, suggesting that Tang Mai Kang Capsule functions to decrease blood sugar level and improve the complicated angioneurotic lesions of diabetes.

  14. Benchmarking uranyl peroxide capsule chemistry in organic media

    Energy Technology Data Exchange (ETDEWEB)

    Neal, Harrison A.; Nyman, May [Department of Chemistry, Oregon State University, Corvallis, OR (United States); Szymanowski, Jennifer; Fein, Jeremy B.; Burns, Peter C. [Department of Civil and Environmental Engineering and Earth Sciences, University of Notre Dame, Notre Dame, IN (United States)

    2017-01-03

    Uranyl peroxide capsules are a recent addition to polyoxometalate (POM) chemistry. Ten years of development has ensued only in water, while transition metal POMs are commonly exploited in aqueous and organic media, controlled by counterions or ligation to render the clusters hydrophilic or hydrophobic. Here, new uranyl POM behavior is recognized in organic media, including (1) stabilization and immobilization of encapsulated hydrophilic countercations, identified by Li nuclear magnetic resonance (NMR) spectroscopy, (2) formation of new cluster species upon phase transfer, (3) extraction of uranyl clusters from different starting materials including simulated spent nuclear fuel, (4) selective phase transfer of one cluster type from a mixture, and (5) phase transfer of clusters from both acidic and alkaline media. The capsule morphology of the uranyl POMs renders accurate characterization by X-ray scattering, including the distinction of geometrically similar clusters. Compositional analysis of the aqueous phase post-extraction provided a quantitative determination of the ion exchange process that enables transfer of the clusters into the organic phase. Preferential partitioning of uranyl POMs into organic media presents new frontiers in metal ion behavior and chemical reactions in the confined space of the cluster capsules in hydrophobic media, as well as the reactivity of clusters at the organic/aqueous interface. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Benchmarking uranyl peroxide capsule chemistry in organic media

    International Nuclear Information System (INIS)

    Neal, Harrison A.; Nyman, May; Szymanowski, Jennifer; Fein, Jeremy B.; Burns, Peter C.

    2017-01-01

    Uranyl peroxide capsules are a recent addition to polyoxometalate (POM) chemistry. Ten years of development has ensued only in water, while transition metal POMs are commonly exploited in aqueous and organic media, controlled by counterions or ligation to render the clusters hydrophilic or hydrophobic. Here, new uranyl POM behavior is recognized in organic media, including (1) stabilization and immobilization of encapsulated hydrophilic countercations, identified by Li nuclear magnetic resonance (NMR) spectroscopy, (2) formation of new cluster species upon phase transfer, (3) extraction of uranyl clusters from different starting materials including simulated spent nuclear fuel, (4) selective phase transfer of one cluster type from a mixture, and (5) phase transfer of clusters from both acidic and alkaline media. The capsule morphology of the uranyl POMs renders accurate characterization by X-ray scattering, including the distinction of geometrically similar clusters. Compositional analysis of the aqueous phase post-extraction provided a quantitative determination of the ion exchange process that enables transfer of the clusters into the organic phase. Preferential partitioning of uranyl POMs into organic media presents new frontiers in metal ion behavior and chemical reactions in the confined space of the cluster capsules in hydrophobic media, as well as the reactivity of clusters at the organic/aqueous interface. (copyright 2017 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Expert Consensus on the Treatment of Hypertension with Chinese Patent Medicines

    Directory of Open Access Journals (Sweden)

    Li Ying Wang

    2013-01-01

    Full Text Available Objectives. This study was aimed to determine the therapeutic principle and identify Chinese Patent Medicine (CPM with corresponding indications for hypertension treatment. Methods. Three rounds of Delphi survey were mailed among 40 cardiovascular integrative medicine specialists. Items with agreement of more than 80% respondents were included in the consensus. Results. According to majority of the panelists, CPM is suitable for most hypertensive patients and should be used according to traditional Chinese medicine pattern classification. CPM could be used alone for grade 1 hypertension and could be used in combination with Western biomedicine (WM for both grade 2 and grade 3 hypertension. It is recommended that less than two CPMs are used simultaneously. For the treatment of grade 2 and 3 hypertension, CPM and WM should be taken separately. Recommended CPMs included Tianma Gouteng granule, Qiju Dihuang capsule, Jinkui Shenqi pill, Yinxingye tablet, Niuhuang Jiangya pill and Banxia Tianma pill. The indications of 4 CPMs were specified with symptoms related to TCM pattern classification by the experts. Conclusions. An expert consensus on CMP application was formed for the treatment of hypertension in the form of integrative medicine. A flow of IM hypertension management was proposed based on the results of the survey.

  17. Effects of glucosamine on proteoglycan loss by tendon, ligament and joint capsule explant cultures.

    Science.gov (United States)

    Ilic, M Z; Martinac, B; Samiric, T; Handley, C J

    2008-12-01

    To investigate the effect of glucosamine on the loss of newly synthesized radiolabeled large and small proteoglycans by bovine tendon, ligament and joint capsule. The kinetics of loss of (35)S-labeled large and small proteoglycans from explant cultures of tendon, ligament and joint capsule treated with 10mM glucosamine was investigated over a 10-day culture period. The kinetics of loss of (35)S-labeled small proteoglycans and the formation of free [(35)S]sulfate were determined for the last 10 days of a 15-day culture period. The proteoglycan core proteins were analyzed by gel electrophoresis followed by fluorography. The metabolism of tendon, ligament and joint capsule explants exposed to 10mM glucosamine was evaluated by incorporation of [(3)H]serine and [(35)S]sulfate into protein and glycosaminoglycans, respectively. Glucosamine at 10mM stimulated the loss of small proteoglycans from ligament explant cultures. This was due to the increased loss of both macromolecular and free [(35)S]sulfate to the medium indicating that glucosamine affected the release of small proteoglycans as well as their intracellular degradation. The degradation pattern of small proteoglycans in ligament was not affected by glucosamine. In contrast, glucosamine did not have an effect on the loss of large or small proteoglycans from tendon and joint capsule or large proteoglycans from ligament explant cultures. The metabolism of cells in tendon, ligament and joint capsule was not impaired by the presence of 10mM glucosamine. Glucosamine stimulated the loss of small proteoglycans from ligament but did not have an effect on small proteoglycan catabolism in joint capsule and tendon or large proteoglycan catabolism in ligament, tendon or synovial capsule. The consequences of glucosamine therapy at clinically relevant concentrations on proteoglycan catabolism in joint fibrous connective tissues need to be further assessed in an animal model.

  18. Short-wavelength and three-dimensional instability evolution in National Ignition Facility ignition capsule designs

    International Nuclear Information System (INIS)

    Clark, D. S.; Haan, S. W.; Cook, A. W.; Edwards, M. J.; Hammel, B. A.; Koning, J. M.; Marinak, M. M.

    2011-01-01

    Ignition capsule designs for the National Ignition Facility (NIF) [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 443, 2841 (2004)] have continued to evolve in light of improved physical data inputs, improving simulation techniques, and, most recently, experimental data from a growing number of NIF sub-ignition experiments. This paper summarizes a number of recent changes to the cryogenic capsule design and some of our latest techniques in simulating its performance. Specifically, recent experimental results indicated harder x-ray drive spectra in NIF hohlraums than were predicted and used in previous capsule optimization studies. To accommodate this harder drive spectrum, a series of high-resolution 2-D simulations, resolving Legendre mode numbers as high as 2000, were run and the germanium dopant concentration and ablator shell thicknesses re-optimized accordingly. Simultaneously, the possibility of cooperative or nonlinear interaction between neighboring ablator surface defects has motivated a series of fully 3-D simulations run with the massively parallel HYDRA code. These last simulations include perturbations seeded on all capsule interfaces and can use actual measured shell surfaces as initial conditions. 3-D simulations resolving Legendre modes up to 200 on large capsule sectors have run through ignition and burn, and higher resolution simulations resolving as high as mode 1200 have been run to benchmark high-resolution 2-D runs. Finally, highly resolved 3-D simulations have also been run of the jet-type perturbation caused by the fill tube fitted to the capsule. These 3-D simulations compare well with the more typical 2-D simulations used in assessing the fill tube's impact on ignition. Coupled with the latest experimental inputs from NIF, our improving simulation capability yields a fuller and more accurate picture of NIF ignition capsule performance.

  19. Investigation of natural frequencies of laser inertial confinement fusion capsules using resonant ultrasound spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Xiaojun [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Research Center of Laser Fusion, CAEP, Mianyang 621900 (China); Tang, Xing; Wang, Zongwei [Research Center of Laser Fusion, CAEP, Mianyang 621900 (China); Chen, Qian; Qian, Menglu [Institute of Acoustic, Tongji University, Shanghai 200433 (China); Meng, Jie [Research Center of Laser Fusion, CAEP, Mianyang 621900 (China); Tang, Yongjian [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Research Center of Laser Fusion, CAEP, Mianyang 621900 (China); Zou, Yaming; Shen, Hao [Institute of Modern Physics, Fudan University, Shanghai 200433 (China); Gao, Dangzhong, E-mail: dgaocn@163.com [Research Center of Laser Fusion, CAEP, Mianyang 621900 (China)

    2017-01-15

    Highlights: • The frequency equation of isotropic multi-layer hollow spheres was derived using three-dimension (3D) elasticity theory and transfer matrix method. • The natural frequencies of the capsules with a millimeter-sized diameter are determined experimentally using resonant ultrasound spectrum (RUS) system. • The predicted natural frequencies of the frequency equation accord well with the observed results. • The theoretical and experimental investigation has proved the potential applicability of RUS to both metallic and non-metallic capsules. - Abstract: The natural frequency problem of laser inertial confinement fusion (ICF) capsules is one of the basic problems for determining non-destructively the elasticity modulus of each layer material using resonant ultrasound spectroscopy (RUS). In this paper, the frequency equation of isotropic one-layer hollow spheres was derived using three dimension (3D) elasticity theory and some simplified frequency equations were discussed under axisymmetric and spherical symmetry conditions. The corresponding equation of isotropic multi-layer hollow spheres was given employing transfer matrix method. To confirm the validity of the frequency equation and explore the feasibility of RUS for characterizing the ICF capsules, three representative capsules with a millimeter-sized diameter were determined by piezoelectric-based resonant ultrasound spectroscopy (PZT-RUS) and laser-based resonant ultrasound spectroscopy (LRUS) techniques. On the basis of both theoretical and experimental results, it is proved that the calculated and measured natural frequencies are accurate enough for determining the ICF capsules.

  20. Management of the Cs/Sr Capsule Project at the Hanford Site. Technology Readiness Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2018-01-01

    The Federal Project Director (FPD) for the U.S. Department of Energy (DOE), Richland Operations Office (RL) Waste Management and D&D Division (WMD) requested a Technology Readiness Assessment (TRA) for the Management of the Cesium/Strontium Capsule Storage Project (MCSCP) at the Waste Encapsulation and Storage Facility (WESF) on the Hanford Site in Washington State. The MCSCP CD-1 TRA was performed by a team selected in collaboration between the Office of Environmental Management (EM) Chief Engineer (EM-3.3) and RL, WMD FPD. The TRA Team included subject matter and technical experts having experience in cask storage, process engineering, and system design who were independent of the MCSCP, and the team was led by the Director of Operations and Processes from the EM Chief Engineer's Office (EM-3.32). Movement of the Cs/Sr capsules to dry storage, based on information from the conceptual design, involves (1) capsule packaging, (2) capsule transfer, and (3) capsule storage. The project has developed a conceptual process, described in 30059-R-02, "NAC Conceptual Design Report for the Management of the Cesium and Strontium Capsules Project", which identifies the five major activities in the process to complete the transfer from storage pool to pad-mounted cask storage. The process, shown schematically in Figure 1, is comprised of the following process steps: (1) loading capsules into the UCS; (2) UCS processing; (3) UCS insertion into the TSC Basket; (4) cask transport from WESF to CSA and (5) extended storage at the CSA.

  1. Simulation of fuel rod irradiation capsules in water loops by electric heater rods

    International Nuclear Information System (INIS)

    Lopez, J.; Montes, M.; Serrano, J.; Haefner, H.E.

    1984-01-01

    The out of pile simulation of irradiation devices was carried out by J.E.N. in the frame of the KfK-JEN joint experiment for irradiation of fast reactor fuel rods (IVO-FR2-Vg7). A typical single-wall-Nak (22% Na, 78% K) electrical heated capsule was fabricated and hydraulical tests were done. The capsule was instrumented with 10 thermocouples in order to obtain the radial temperature profile into the capsule in function of the electrical rod power (max. 215 w/cm), flow rate (max. 2,4 m 3 /h) and coolant temperature (max. 60degC). The experimental values are compared to the Tecap-Code results. (author)

  2. Chinese nuclear insurance and Chinese nuclear insurance pool

    International Nuclear Information System (INIS)

    Gong Zhiqi

    2000-01-01

    Chinese Nuclear Insurance Started with Daya Bay Nuclear Power Station, PICC issued the insurance policy. Nuclear insurance cooperation between Chinese and international pool's organizations was set up in 1989. In 1996, the Chinese Nuclear Insurance Pool was prepared. The Chinese Nuclear Insurance Pool was approved by The Chinese Insurance Regulatory Committee in May of 1999. The principal aim is to centralize maximum the insurance capacity for nuclear insurance from local individual insurers and to strengthen the reinsurance relations with international insurance pools so as to provide the high quality insurance service for Chinese nuclear industry. The Member Company of Chinese Nuclear Pool and its roles are introduced in this article

  3. A Machine Learning Approach for Intestinal Motility Assessment with Capsule Endoscopy

    OpenAIRE

    Vilariño Freire, Fernando Luis

    2006-01-01

    Consultable des del TDX Intestinal motility assessment with video capsule endoscopy arises as a novel and challenging clinical fieldwork. This technique is based on the analysis of the patterns of intestinal contractions obtained by labelling all the motility events present in a video provided by a capsule with a wireless micro-camera, which is ingested by the patient. However, the visual analysis of these video sequences presents several important drawbacks, mainly related to both the lar...

  4. Potassium iodide capsule treatment of feline sporotrichosis.

    Science.gov (United States)

    Reis, Erica G; Gremião, Isabella D F; Kitada, Amanda A B; Rocha, Raphael F D B; Castro, Verônica S P; Barros, Mônica B L; Menezes, Rodrigo C; Pereira, Sandro A; Schubach, Tânia M P

    2012-06-01

    Sporotrichosis is a mycosis caused by Sporothrix schenckii. The most affected animal is the cat; it has played an important role in the zoonotic transmission of this disease, especially in Rio de Janeiro, Brazil, since 1998. In order to evaluate the treatment of feline sporotrichosis with potassium iodide, an observational cohort was conducted in 48 cats with sporotrichosis at Instituto de Pesquisa Clínica Evandro Chagas, Fiocruz. All cats received potassium iodide capsules, 2.5 mg/kg to 20 mg/kg q24h. The cure rate was 47.9%, treatment failure was 37.5%, treatment abandonment was 10.4% and death was 4.2%. Clinical adverse effects were observed in 52.1% of the cases. Thirteen cats had a mild increase in hepatic transaminase levels during the treatment, six of them presented clinical signs suggestive of hepatotoxicity. Compared to previous studies with itraconazole and iodide in saturated solution, potassium iodide capsules are an alternative for feline sporotrichosis treatment.

  5. MRI diagnosis of reverse and separation of meniscus articular capsule

    International Nuclear Information System (INIS)

    Tang Xiaofeng; Zhou Chengtao; Mu Renqi; Zhang Guanghui; Xu Yongzhong

    2005-01-01

    Objective: To explore the MR imaging of reverse and separation of meniscal articular capsule. Methods: MR imaging of reverse and separation of meniscus articular capsule confirmed by surgery and arthroscope were analyzed retrospectively in 8 cases. Results: The 'Butterfly knot sign' disappeared and was replaced with fluid signal on the sagittal slice of meniscal body in 8 cases. Part of back angle remained in 3 cases. 'Double anterior cruciate ligament sign' was showed on one side of middle sagittal slice in 7 cases. 'Reverse meniscus sign' was revealed in intercondylar fossa on the coronary view in 8 cases. Abnormal high signal was showed in the injured meniscus in 6 cases. Abnormal high signal was detected in the opposite meniscus in 5 cases. Conclusion: The MR findings of reverse and separation of meniscus articular capsule include disappearance of 'butterfly knot sign', appearance of 'reverse meniscus sign' and 'double anterior cruciate ligament sign'. The diagnosis would be established if the former 2 signs were present or all the 3 signs were present simultaneously. (authors)

  6. Analysis and radiation dose rate measurement of the Al-1050 capsule on the rabbit system facility

    International Nuclear Information System (INIS)

    Sarwani; Sutrisno; H, Saleh; Rohidi; M, Kawkab

    2000-01-01

    Aluminium is a kind of light metal with density of 2.7 gram /cm exp 3,regarding to the aluminium is characteristic such as easy to fabricated,has a good corrosion resistant and radiation heat resistant, therefore aluminum is selected to be used as a material for sample irradiation capsule with high neutron fluency. Analysis using neutron activation method and capsule irradiation by using high neutron fluency and dose radiation rate measurement was done. The analysis result show that impurities in the Al-1050 capsule are Fe, Cu, Mg, Sb, Zn, and Mn. The capsule irradiated at 15 MW during 6 Hours with neutron fluency of 2,8 x 10 exp 17 n/cm exp 2. The radiation doses rate after 24 hours decay is 220 mrad/h at 0-meter distance and 60 mrad/h at 1-meter distance. Respectively. From the analysis results and measurement show that the Al-1050 capsule has no high neutron absorption element and available to get continuing irradiation at 15 MW as far as 6 hours. Due to the personal safety, therefore the capsule handling could be carried out in the hot cell

  7. Irradiation capsule for testing magnetic fusion reactor first-wall materials at 60 and 2000C

    International Nuclear Information System (INIS)

    Conlin, J.A.

    1985-08-01

    A new type of irradiation capsule has been designed, and a prototype has been tested in the Oak Ridge Research Reactor (ORR) for low-temperature irradiation of Magnetic Fusion Reactor first-wall materials. The capsule meets the requirements of the joint US/Japanese collaborative fusion reactor materials irradiation program for the irradiation of first-wall fusion reactor materials at 60 and 200 0 C. The design description and results of the prototype capsule performance are presented

  8. Contraindications for video capsule endoscopy

    OpenAIRE

    Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin

    2016-01-01

    Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn?s dise...

  9. Seismic analysis for shroud facility in-pile tube and saturated temperature capsules

    International Nuclear Information System (INIS)

    Iimura, Koichi; Yamaura, Takayuki; Ogawa, Mitsuhiro

    2009-07-01

    At Oarai Research and Development Center, Japan Atomic Energy Agency (JAEA), the plan of repairing and refurbishing Japan Materials Testing Reactor (JMTR) has progressed in order to restart JMTR operation in the fiscal 2011. As a part of effective use of JMTR, the neutron irradiation tests of LWR fuels and materials has been planned in order to study their soundness. By using Oarai Shroud Facility (OSF-1) and Fuel Irradiation Facility with the He-3 gas control system for power lamping test using Boiling Water Capsules (BOCA Irradiation Facility), the irradiation tests with power ramping will be carried out to study the soundness of fuel under LWR Transient condition. OSF-1 is the irradiation facility of shroud type that can insert and eject the capsule under reactor operation, and is composed of 'In-pile Tube', 'Cooling system' and 'Capsule exchange system'. BOCA Irradiation Facility is the facility which simulates irradiation environment of LWR, and is composed of 'Boiling water Capsule', 'Capsule control system' and 'Power control system by He-3'. By using Saturated temperature Capsules and the water environment control system, the material irradiation tests under the water chemistry condition of LWR will be carried out to clarify the mechanism of IASCC. In JMTR, these facilities are in service at the present. However, the detailed design for renewal or remodeling was carried out based on the new design condition in order to be correspondent to the irradiation test plan after restart JMTR operation. In this seismic analysis of the detailed design, each equipment classification and operating state were arranged with 'Japanese technical standards of the structure on nuclear facility for test research' and 'Technical guidelines for seismic design of nuclear power plants on current, and then, stress calculation and evaluation were carried out by FEM piping analysis code 'SAP' and structure analysis code 'ABAQUS'. About the stress of the seismic force, it was proven

  10. Return of isotope capsules to the Waste Encapsulation and Storage Facility

    International Nuclear Information System (INIS)

    1994-05-01

    Cesium-137 and strontium-90 isotopes were removed from Hanford Site high-level tank wastes, and were encapsulated at the Hanford Site's Waste Encapsulation and Storage Facility (WESF), beginning in 1974. Over the past several years, radioactive isotope capsules have been sent to other U.S. Department of Energy (DOE)-controlled sites to be used for research and development applications, as well as leased to a number of commercial facilities for commercial applications (e.g., sterilization of medical supplies). Due to uncertainty regarding the cause of the release of a small quantity of cesium-137 to an isolated water basin from a WESF cesium-137 capsule in a commercial facility in Decatur, Georgia, the DOE has determined that it needs to return leased capsules from IOTECH, Incorporated (IOTECH), Northglenn, Colorado; Pacific Northwest Laboratory (PNL), Richland, Washington; and the Applied Radiant Energy Corporation (ARECO), Lynchburg, Virginia; to the WESF Facility on the Hanford Site, to ensure safe management and storage, pending final disposition. All of these capsules located at the commercial facilities were successfully tested during Calendar Year 1993, and none showed any indication of off-normal specifications. Storage at the WESF will continue under the actions selected in the Record of Decision for the Final Environmental Impact Statement: Disposal of Hanford Defense High-Level, Transuranic and Tank Wastes, Hanford Site, Richland, Washington

  11. Remote controlled capsules in human drug absorption (HDA) studies.

    Science.gov (United States)

    Wilding, Ian R; Prior, David V

    2003-01-01

    The biopharmaceutical complexity of today's new drug candidates provides significant challenges for pharmaceutical scientists in terms of both candidate selection and optimizing subsequent development strategy. In addition, life cycle management of marketed drugs has become an important income stream for pharmaceutical companies, but the selection of least risk/highest benefit strategies is far from simple. The proactive adoption of human drug absorption (HDA) studies using remote controlled capsules offers the pharmaceutical scientist significant guidance for planning a route through the maze of product development. This review examines the position of HDA studies in drug development, using a variety of case histories and an insightful update on remote controlled capsules to achieve site-specific delivery.

  12. Capsule Design for Blue Light Therapy against Helicobacter pylori.

    Science.gov (United States)

    Li, Zhangyong; Ren, Binbin; Tan, Haiyan; Liu, Shengrong; Wang, Wei; Pang, Yu; Lin, Jinzhao; Zeng, Chen

    2016-01-01

    A photo-medical capsule that emits blue light for Helicobacter pylori treatment was described in this paper. The system consists of modules for pH sensing and measuring, light-emitting diode driver circuit, radio communication and microcontroller, and power management. The system can differentiate locations by monitoring the pH values of the gastrointestinal tract, and turn on and off the blue light according to the preset range of pH values. Our experimental tests show that the capsule can operate in the effective light therapy mode for more than 32 minutes and the wireless communication module can reliably transmit the measured pH value to a receiver located outside the body.

  13. Design and manufacturing of 05F-01K instrumented capsule for nuclear fuel irradiation in Hanaro

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, J. M.; Shin, Y. T.; Park, S. J. (and others)

    2007-07-15

    An instrumented capsule was developed to be able to measure fuel characteristics, such as fuel temperature, internal pressure of fuel rod, fuel pellet elongation, and neutron flux, etc., during the irradiation test of nuclear fuel in Hanaro. The instrumented capsule(02F-11K) for measuring and monitoring and monitoring fuel centerline temperature and neutron flux was designed and manufactured. It was successfully irradiated in the test hole OR5 of Hanaro from March 14, 2003 to June 1, 2003 (53.84 full power days at 24 MW). In the year of 2004, 3 test fuel rods and the instrumented capsule(03F-05K) were designed and manufactured to measure fuel centerline temperature, internal pressure of fuel rod, and fuel axial deformation during irradiation test. This capsule was irradiated in the test hole OR5 of Hanaro reactor from April 26, 2004 to October 1, 2004 (59.5 EFPD at 24 {approx} 30 MW). The six typed dual instrumented fuel rods, which allow for two characteristics to be measured simultaneously in one fuel rod, have been designed and manufactured to enhance the efficiency of the irradiation test using the instrumented fuel capsule. The 05F-01K instrumented fuel capsule was designed and manufactured for a design verification test of the three dual instrumented fuel rods. The irradiation test of the 05F-01K instrumented fuel capsule will be carried out at the OR5 vertical experimental hole of Hanaro.

  14. An x-ray-based capsule for colorectal cancer screening incorporating single photon counting technology

    Science.gov (United States)

    Lifshitz, Ronen; Kimchy, Yoav; Gelbard, Nir; Leibushor, Avi; Golan, Oleg; Elgali, Avner; Hassoon, Salah; Kaplan, Max; Smirnov, Michael; Shpigelman, Boaz; Bar-Ilan, Omer; Rubin, Daniel; Ovadia, Alex

    2017-03-01

    An ingestible capsule for colorectal cancer screening, based on ionizing-radiation imaging, has been developed and is in advanced stages of system stabilization and clinical evaluation. The imaging principle allows future patients using this technology to avoid bowel cleansing, and to continue the normal life routine during procedure. The Check-Cap capsule, or C-Scan ® Cap, imaging principle is essentially based on reconstructing scattered radiation, while both radiation source and radiation detectors reside within the capsule. The radiation source is a custom-made radioisotope encased in a small canister, collimated into rotating beams. While traveling along the human colon, irradiation occurs from within the capsule towards the colon wall. Scattering of radiation occurs both inside and outside the colon segment; some of this radiation is scattered back and detected by sensors onboard the capsule. During procedure, the patient receives small amounts of contrast agent as an addition to his/her normal diet. The presence of contrast agent inside the colon dictates the dominant physical processes to become Compton Scattering and X-Ray Fluorescence (XRF), which differ mainly by the energy of scattered photons. The detector readout electronics incorporates low-noise Single Photon Counting channels, allowing separation between the products of these different physical processes. Separating between radiation energies essentially allows estimation of the distance from the capsule to the colon wall, hence structural imaging of the intraluminal surface. This allows imaging of structural protrusions into the colon volume, especially focusing on adenomas that may develop into colorectal cancer.

  15. On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy

    Science.gov (United States)

    Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.

    2011-03-01

    Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.

  16. Introduction to the physics of ICF capsules

    International Nuclear Information System (INIS)

    Lindl, J.D.

    1989-01-01

    Inertial Confinement Fusion is an approach to fusion which relies on the inertia of the fuel mass to provide confinement. To achieve conditions under which this confinement is sufficient for efficient thermonuclear burn, high gain ICF targets designed to be imploded directly by laser light. These capsules are generally a spherical shell which is filled with low density DT gas. The shell is composed of an outer region which forms the ablator and an inner region of frozen or liquid DT which forms the main fuel. Energy from the driver is delivered to the ablator which heats up and expands. As the ablator expands and blows outward, the rest of the shell is forced inward to conserve momentum. In this implosion process, several features are important. We define the in-flight-aspect-ratio (IFAR) as the ratio of the shell radius R as it implodes to its thickness ΔR. Hydrodynamic instabilities during the implosion impose limits on this ratio which results in a minimum pressure requirement of about 100 Mbar. The convergence ratio is defined as the ratio of the initial outer radius of the ablator to the final compressed radius of the hot spot. This hot spot is the central region of the compressed fuel which is required to ignite the main fuel in high gain designs. Typical convergence ratios are 30--40. To maintain a nearly spherical shape during the implosion, when convergence ratios are this large, the flux delivered to the capsule must be uniform to a few percent. The remainder of this paper discusses the conditions necessary to achieve thermonuclear ignition in these ICF capsules

  17. Protective Effect of Piper aduncum Capsule on DMBA-induced Breast Cancer in Rats.

    Science.gov (United States)

    Arroyo-Acevedo, J; Chávez-Asmat, R J; Anampa-Guzmán, A; Donaires, R; Ráez-Gonzáles, José

    2015-01-01

    The possible protective effect of Piper aduncum capsule on DMBA (dimethylbenz[α]anthracene)-induced breast cancer in rats was assessed by monitoring the tumor and lung metastases incidence and recording hematological and biochemical parameters and frequency of micronuclei. Mammary carcinogenesis was induced in 36 female Holtzman rats by providing a single subcutaneous injection of DMBA. Oral administration of P. aduncum capsule lowered adenocarcinoma and lymph node metastases incidence. Pulmonary metastasis was significantly lowered (P < 0.05). Hematological indicators showed that the triglyceride level was significantly lowered (P < 0.01) and high-density lipoprotein (HDL) level was significantly increased (P < 0.01). Also, P. aduncum capsule significantly lowered the C reactive protein (CRP) level (P < 0.01) and malondialdehyde level (P < 0.05). There was a significant decrease in the frequency of DMBA-induced micronucleated polychromatic erythrocyte (P < 0.01). Considering the antitumorigenic, hypolipidemic, anti-inflammatory, antioxidant, and antigenotoxic properties of P. aduncum capsule, we conclude that it has a protective effect on DMBA-induced breast cancer in rats.

  18. Demonstration of high coupling efficiency to Al capsule in rugby hohlraum on NIF

    Science.gov (United States)

    Ping, Y.; Smalyuk, V.; Amendt, P.; Bennett, D.; Chen, H.; Dewald, E.; Goyon, C.; Graziani, F.; Johnson, S.; Khan, S.; Landen, O.; Nikroo, A.; Pino, J.; Ralph, J.; Seugling, R.; Strozzi, D.; Tipton, R.; Tommasini, R.; Wang, M.; Loomis, E.; Merritt, E.; Montgomery, D.

    2017-10-01

    A new design of the double-shell approach predicts a high coupling efficiency from the hohlraum to the capsule, with 700 kJ in the capsule instead of 200kJ in the conventional low-Z single-shell scheme, improving prospects of double-shell performance. A recent experiment on NIF has evaluated a first step toward this goal of energy coupling using 0.7x subscale Al capsule, Au rugby hohlraum and 1MJ drive. A shell velocity of 150 μm/ns was measured, DANTE peak temperature of 255 eV was measured, and shell kinetic energy of 36 kJ was inferred using a rocket model, all close to predictions and consistent with 330kJ of total energy coupled to the capsule. Data analysis and more results from subsequent experiments will be presented. In the next step, an additional 2x increase of total coupled energy up to 700 kJ is projected for full-scale 2-MJ drive in U Rugby hohlraum. This work was performed under DOE contract DE-AC52-07NA27344.

  19. Introduction of a theoretical splashing degree to assess the performance of low-viscosity oils in filling of capsules.

    Science.gov (United States)

    Niederquell, Andreas; Kuentz, Martin

    2011-03-01

    These days an alternative to soft capsules is liquid-filled hard capsules. Their filling technology was investigated earlier with highly viscous formulations, while hardly any academic research focused on low-viscosity systems. Accordingly, this work addressed the filling of such oils that are splashing during the dosing process. It was aimed to first study capsule filling, using middle-chain triglycerides as reference oil, in order to then evaluate the concept of a new theoretical splashing degree for different oils. A laboratory-scale filling machine was used that included capsule sealing. Thus, the liquid encapsulation by microspray technology was employed to seal the dosage form. As a result of the study with reference oil, the filling volume and the temperature were found to be significant for the rate of leaking capsules. The filling volume was also important for weight variability of the capsules. However, most critical for this variability was the diameter of the filling nozzle. We proposed a power law for the coefficient of weight variability as a function of the nozzle diameter and the obtained exponent agreed with the proposed theory. Subsequently, a comparison of different oils revealed that the relative splashing degree shared a correlation with the coefficient of the capsule weight variability (Pearson product moment correlation of r=0.990). The novel theoretical concept was therefore found to be predictive for weight variability of the filled capsules. Finally, guidance was provided for the process development of liquid-filled capsules using low-viscosity oils. © 2011 American Association of Pharmaceutical Scientists

  20. Back-to-back colon capsule endoscopy and optical colonoscopy in colorectal cancer screening individuals

    DEFF Research Database (Denmark)

    Kobaek-Larsen, Morten; Kroijer, Rasmus; Dyrvig, Anne-Kirstine

    2018-01-01

    mm polyps in colon capsule endoscopy (97%; 95% CI: 94-100) was superior to colonoscopy (89%; 95% CI: 84-94). A complete capsule endoscopy examination (N=134) could detect patients with intermediate or greater risk (according to the European guidelines) with an accuracy, sensitivity, specificity...... and positivity rate of 79%, 93%, 69% and 58% respectively, using a cut-off of at least one polyp >10 mm or more than two polyps. CONCLUSION: Colon capsule endoscopy is superior to colonoscopy in polyp detection rate and per-patient sensitivity to >9 mm polyps, but only in complete CCE examinations. The rate...

  1. Pharmacokinetic Study of a Capsule-based Chronomodulated Drug ...

    African Journals Online (AJOL)

    cross-linked gelatin capsule shells containing salbutamol pellets, and sealed with a suitable mixture of ... delivered at a constant rate, since the drug effect decreases with time at .... parameters were analyzed by Wilcoxon Signed. Rank test for ...

  2. 21 CFR 520.1920 - Prochlorperazine, isopropamide sustained release capsules.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS ORAL DOSAGE FORM NEW ANIMAL DRUGS... dogs in which gastrointestinal disturbances are associated with emotional stress. (2)(i) Capsules...

  3. Capsule Endoscopy in the Assessment of Obscure Gastrointestinal Bleeding: An Evidence-Based Analysis

    Science.gov (United States)

    2015-01-01

    Background Obscure gastrointestinal bleeding (OGIB) is defined as persistent or recurrent bleeding associated with negative findings on upper and lower gastrointestinal (GI) endoscopic evaluations. The diagnosis and management of patients with OGIB is particularly challenging because of the length and complex loops of the small intestine. Capsule endoscopy (CE) is 1 diagnostic modality that is used to determine the etiology of bleeding. Objectives The objective of this analysis was to review the diagnostic accuracy, safety, and impact on health outcomes of CE in patients with OGIB in comparison with other diagnostic modalities. Data Sources A literature search was performed using Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid Embase, the Wiley Cochrane Library, and the Centre for Reviews and Dissemination database, for studies published between 2007 and 2013. Review Methods Data on diagnostic accuracy, safety, and impact on health outcomes were abstracted from included studies. Quality of evidence was assessed using Grading of Recommendations Assessment, Development, and Evaluation (GRADE). Results The search yielded 1,189 citations, and 24 studies were included. Eight studies reported diagnostic accuracy comparing CE with other diagnostic modalities. Capsule endoscopy has a higher sensitivity and lower specificity than magnetic resonance enteroclysis, computed tomography, and push enteroscopy. Capsule endoscopy has a good safety profile with few adverse events, although comparative safety data with other diagnostic modalities are limited. Capsule endoscopy is associated with no difference in patient health-related outcomes such as rebleeding or follow-up treatment compared with push enteroscopy, small-bowel follow-through, and angiography. Limitations There was significant heterogeneity in estimates of diagnostic accuracy, which prohibited a statistical summary of findings. The analysis was also limited by the fact that there is no

  4. Gas1 expression in parietal cells of Bowman's capsule in experimental diabetic nephropathy.

    Science.gov (United States)

    Luna-Antonio, Brenda I; Rodriguez-Muñoz, Rafael; Namorado-Tonix, Carmen; Vergara, Paula; Segovia, Jose; Reyes, Jose L

    2017-07-01

    Gas1 (Growth Arrest-Specific 1) is a pleiotropic protein with novel functions including anti-proliferative and proapoptotic activities. In the kidney, the expression of Gas1 has been described in mesangial cells. In this study, we described that renal parietal cells of Bowman's capsule (BC) and the distal nephron cells also express Gas1. The role of Gas1 in the kidney is not yet known. There is a subpopulation of progenitor cells in Bowman's capsule with self-renewal properties which can eventually differentiate into podocytes as a possible mechanism of regeneration in the early stages of diabetic nephropathy. We analyzed the expression of Gas1 in the parietal cells of Bowman's capsule in murine experimental diabetes. We found that diabetes reduced the expression of Gas1 and increased the expression of progenitor markers like NCAM, CD24, and SIX1/2, and mesenchymal markers like PAX2 in the Bowman's capsule. We also analyzed the expression of WT1 (a podocyte-specific marker) on BC and observed an increase in the number of WT1 positive cells in diabetes. In contrast, nephrin, another podocyte-specific protein, decreases its expression in the first week of diabetes in the glomerular tuft, which is gradually restored during the second and third weeks of diabetes. These results suggest that in diabetes the decrease of Gas1 promotes the activation of parietal progenitor cells of Bowman's capsule that might differentiate into podocytes and compensate their loss observed in this pathology.

  5. White matter alterations in the internal capsule and psychomotor impairment in melancholic depression.

    Science.gov (United States)

    Hyett, Matthew P; Perry, Alistair; Breakspear, Michael; Wen, Wei; Parker, Gordon B

    2018-01-01

    Emerging evidence suggests that structural brain abnormalities may play a role in the pathophysiology of melancholic depression. We set out to test whether diffusion-derived estimates of white matter structure were disrupted in melancholia in regions underpinning psychomotor function. We hypothesized that those with melancholia (and evidencing impaired psychomotor function) would show disrupted white matter organization in internal capsule subdivisions. Diffusion magnetic resonance imaging (dMRI) data were acquired from 22 melancholic depressed, 23 non-melancholic depressed, and 29 healthy control participants. Voxel-wise fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) values were derived for anterior, posterior, and retrolenticular limbs of the internal capsule and compared between groups. Neuropsychological (reaction time) and psychomotor functioning were assessed and correlated against FA. Fractional anisotropy was distinctly increased, whilst RD was decreased, in the right anterior internal capsule in those with melancholia, compared to controls. The right anterior limb of the internal capsule correlated with clinical ratings of psychomotor disturbance, and reduced psychomotor speed was associated with increased FA values in the right retrolenticular limb in those with melancholia. Our findings highlight a distinct disturbance in the local white matter arrangement in specific regions of the internal capsule in melancholia, which in turn is associated with psychomotor dysfunction. This study clarifies the contribution of structural brain integrity to the phenomenology of melancholia, and may assist future efforts seeking to integrate neurobiological markers into depression subtyping.

  6. Irradiation capsule design capable of continuously monitoring the creepdown of Zircaloy fuel cladding

    International Nuclear Information System (INIS)

    Thoms, K.R.; Dodd, C.V.; van der Kaa, T.; Hobson, D.O.

    1978-01-01

    An irradiation capsule which permits continuous monitoring of the creepdown of Zircaloy tubing has been designed and given preliminary tests. This design effort is the major element of a cooperative research program between the United States Nuclear Regulatory Commission and the Netherlands Energy Research Foundation (ECN) and is a part of the NRC-sponsored Zircaloy creepdown program. The purpose of the Zircaloy creepdown program is to provide data on the deformation characteristics of Zircaloy tubes, typical of LWR fuel element cladding, under combined axial and tangential compressive stresses. These data will be used to verify and improve the material behavior codes that are used for the description of fuel pin behavior. The first capsule of this series contains a mockup test specimen which was machined with three different diameters, nominally 10.92-mm, 10.54-mm and 11.30-mm (.430-in., .415-in., and .445-in.). This test specimen can be moved axially thereby varying the lift-off and serving as a calibration device for the eddy-current deformation monitoring probes. Fabrication of this capsule has been completed and during out-or-reactor checkout we were able to obtain a resolution of better than 0.01-mm (0.0004-in.). The capsule is scheduled for installation in the HFR on February 8, 1978, for a 26 day irradiation test. The first pressurized capsule, and therefore the first one to monitor in-reactor cladding deformation, will be installed in the HFR on May 3, 1978

  7. Breast implant capsule-associated squamous cell carcinoma: a report of 2 cases.

    Science.gov (United States)

    Olsen, Daniel L; Keeney, Gary L; Chen, Beiyun; Visscher, Daniel W; Carter, Jodi M

    2017-09-01

    The use of prosthetic implants for breast augmentation has become commonplace. Although implants do not increase the risk of conventional mammary carcinoma, they are rarely associated with anaplastic large cell lymphoma. We report 2 cases of breast implant capsule-associated squamous cell carcinoma with poor clinical outcomes. Both patients (56-year-old woman and 81-year-old woman) had long-standing implants (>25 years) and presented with acute unilateral breast enlargement. In both cases, squamous cell carcinoma arose in (focally dysplastic) squamous epithelium-lined breast implant capsules and widely invaded surrounding breast parenchyma or chest wall. Neither patient had evidence of a primary mammary carcinoma or squamous cell carcinoma at any other anatomic site. Within 1 year, one patient developed extensive, treatment-refractory, locoregional soft tissue metastasis, and the second patient developed hepatic and soft tissue metastases and died of disease. There are 2 prior reported cases of implant-associated squamous cell carcinoma in the plastic surgery literature; one provides no pathologic staging or outcome information, and the second case was a capsule-confined squamous cell carcinoma. Together, all 4 cases share notable commonalities: the patients had long-standing breast implants and presented with acute unilateral breast pain and enlargement secondary to tumors arising on the posterior aspect of squamous epithelialized implant capsules. Because of both its rarity and its unusual clinical presentation, implant capsule-associated squamous cell carcinoma may be underrecognized. The aggressive behavior of the tumors in this series underscores the importance of excluding malignancy in patients with long-standing breast implants who present with acute unilateral breast pain and enlargement. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Poppy Crop Height and Capsule Volume Estimation from a Single UAS Flight

    Directory of Open Access Journals (Sweden)

    Faheem Iqbal

    2017-06-01

    Full Text Available The objective of this study was to estimate poppy plant height and capsule volume with remote sensing using an Unmanned Aircraft System (UAS. Data were obtained from field measurements and UAS flights over two poppy crops at Cambridge and Cressy in Tasmania. Imagery acquired from the UAS was used to produce dense point clouds using structure from motion (SfM and multi-view stereopsis (MVS techniques. Dense point clouds were used to generate a digital surface model (DSM and orthophoto mosaic. An RGB index was derived from the orthophoto to extract the bare ground spaces. This bare ground space mask was used to filter the points on the ground, and a digital terrain model (DTM was interpolated from these points. Plant height values were estimated by subtracting the DSM and DTM to generate a Crop Height Model (CHM. UAS-derived plant height (PH and field measured PH in Cambridge were strongly correlated with R2 values ranging from 0.93 to 0.97 for Transect 1 and Transect 2, respectively, while at Cressy results from a single flight provided R2 of 0.97. Therefore, the proposed method can be considered an important step towards crop surface model (CSM generation from a single UAS flight in situations where a bare ground DTM is unavailable. High correlations were found between UAS-derived PH and poppy capsule volume (CV at capsule formation stage (R2 0.74, with relative error of 19.62%. Results illustrate that plant height can be reliably estimated for poppy crops based on a single UAS flight and can be used to predict opium capsule volume at capsule formation stage.

  9. Capsule shell material impacts the in vitro disintegration and dissolution behaviour of a green tea extract☆

    Science.gov (United States)

    Glube, Natalie; Moos, Lea von; Duchateau, Guus

    2013-01-01

    Purpose In vitro disintegration and dissolution are routine methods used to assess the performance and quality of oral dosage forms. The purpose of the current work was to determine the potential for interaction between capsule shell material and a green tea extract and the impact it can have on the release. Methods A green tea extract was formulated into simple powder-in-capsule formulations of which the capsule shell material was either of gelatin or HPMC origin. The disintegration times were determined together with the dissolution profiles in compendial and biorelevant media. Results All formulations disintegrated within 30 min, meeting the USP criteria for botanical formulations. An immediate release dissolution profile was achieved for gelatin capsules in all media but not for the specified HPMC formulations. Dissolution release was especially impaired for HPMCgell at pH 1.2 and for both HPMC formulations in FeSSIF media suggesting the potential for food interactions. Conclusions The delayed release from studied HPMC capsule materials is likely attributed to an interaction between the catechins, the major constituents of the green tea extract, and the capsule shell material. An assessment of in vitro dissolution is recommended prior to the release of a dietary supplement or clinical trial investigational product to ensure efficacy. PMID:25755998

  10. Capsule shell material impacts the in vitro disintegration and dissolution behaviour of a green tea extract.

    Science.gov (United States)

    Glube, Natalie; Moos, Lea von; Duchateau, Guus

    2013-01-01

    In vitro disintegration and dissolution are routine methods used to assess the performance and quality of oral dosage forms. The purpose of the current work was to determine the potential for interaction between capsule shell material and a green tea extract and the impact it can have on the release. A green tea extract was formulated into simple powder-in-capsule formulations of which the capsule shell material was either of gelatin or HPMC origin. The disintegration times were determined together with the dissolution profiles in compendial and biorelevant media. All formulations disintegrated within 30 min, meeting the USP criteria for botanical formulations. An immediate release dissolution profile was achieved for gelatin capsules in all media but not for the specified HPMC formulations. Dissolution release was especially impaired for HPMCgell at pH 1.2 and for both HPMC formulations in FeSSIF media suggesting the potential for food interactions. The delayed release from studied HPMC capsule materials is likely attributed to an interaction between the catechins, the major constituents of the green tea extract, and the capsule shell material. An assessment of in vitro dissolution is recommended prior to the release of a dietary supplement or clinical trial investigational product to ensure efficacy.

  11. Effects of alga polysaccharide capsule shells on in-vivo bioavailability and disintegration

    Science.gov (United States)

    Li, Ting; Guo, Shuju; Ma, Lin; Yuan, Yi; Han, Lijun

    2012-01-01

    Gelatin has been used in hard capsule shells for more than a century, and some shortcomings have appeared, such as high moisture content and risk of transmitting diseases of animal origin to people. Based on available studies regarding gelatin and vegetable shells, we developed a new type of algal polysaccharide capsule (APPC) shells. To test whether our products can replace commercial gelatin shells, we measured in-vivo plasma concentration of 12 selected volunteers with a model drug, ibuprofen, using high performance liquid chromatography (HPLC), by calculating the relative bioavailability of APPC and Qualicaps® referenced to gelatin capsules and assessing bioequivalence of the three types of shells, and calculated pharmacokinetic parameters with the software DAS 2.0 (China). The results show that APPC shells possess bioequivalence with Qualicaps® and gelatin shells. Moreover, the disintegration behavior of four types of shells (APPC, Vegcaps®, Qualicaps® and gelatin shells) with the content of lactose and radioactive element (99mTc) was observed via gamma-scintigraphic images. The bioavailability and gamma-scintigraphic studies showed that APPC was not statistically different from other vegetable and gelatin capsule shells with respect to in-vivo behavior. Hence, it can be concluded that APPCs are exchangeable with other vegetable and gelatin shells.

  12. The indentation of pressurized elastic shells: from polymeric capsules to yeast cells

    KAUST Repository

    Vella, D.

    2011-08-10

    Pressurized elastic capsules arise at scales ranging from the 10 m diameter pressure vessels used to store propane at oil refineries to the microscopic polymeric capsules that may be used in drug delivery. Nature also makes extensive use of pressurized elastic capsules: plant cells, bacteria and fungi have stiff walls, which are subject to an internal turgor pressure. Here, we present theoretical, numerical and experimental investigations of the indentation of a linearly elastic shell subject to a constant internal pressure. We show that, unlike unpressurized shells, the relationship between force and displacement demonstrates two linear regimes. We determine analytical expressions for the effective stiffness in each of these regimes in terms of the material properties of the shell and the pressure difference. As a consequence, a single indentation experiment over a range of displacements may be used as a simple assay to determine both the internal pressure and elastic properties of capsules. Our results are relevant for determining the internal pressure in bacterial, fungal or plant cells. As an illustration of this, we apply our results to recent measurements of the stiffness of baker\\'s yeast and infer from these experiments that the internal osmotic pressure of yeast cells may be regulated in response to changes in the osmotic pressure of the external medium.

  13. [Therapeutic effects of the integrated acupuncture and Chinese herbal medicine on reflux esophagitis].

    Science.gov (United States)

    Zhang, Wan; Li, Bolin; Sun, Jianhui; Wang, Zhikun; Zhang, Nana; Shi, Fang; Pei, Lin

    2017-07-12

    To compare the differences in the clinical therapeutic effects on reflux esophagitis among the combined therapy of huazhuo jiedu jiangni decoction (the decoction for resolving the turbid, detoxification and reducing the pathologic upward qi in short) and acupuncture, omeprazole and Chinese herbal medicine. Ninety patients were randomized into 3 groups, 4 cases of them were dropped off. Finally, there were 29 cases in the combined therapy group with acupuncture and the decoction, 29 cases in the western medication group and 28 cases in the Chinese herbal medicine group in the statistical analysis. In the combined therapy group with acupuncture and the decoction, the decoction was prescribed recurrence rate. The therapeutic effects are better than the simple application of either Chinese herbal medicine or omeprazole. for oral administration. Additionally, acupuncture was applied to Neiguan (PC 6), Zusanli (ST 36), Zhongwan (CV 12), Ganshu (BL 18), Danshu (BL 19) and Taichong (LR 3). The decoction was applied one dose a day and acupuncture was once a day. In the western medication group, omeprazole capsules, 20 mg were prescribed for oral administration, twice a day. In the Chinese herbal medicine group, the decoction was simply applied. The treatment was 8 weeks in the 3 groups and the follow-up visit was 6 months. The score of reflux disorder questionnaire (RDQ) and the changes in esophageal mucosa under gastroscope were observed before and after treatment; the clinical therapeutic effects and recurrence rate were evaluated in the 3 groups. In 4 and 8 weeks of treatment, RDQ scores in the 3 groups were all reduced as compared with those before treatment (all P herbal medicine was lower than that in the western medication group ( P herbal medicine was lower than those in the western medication group and the Chinese herbal medicine group (both P herbal medicine group (all P <0.05). The combined therapy of huazhuo jiedu jiangni decoction and acupuncture achieve the

  14. A Pharmacokinetic Bioequivalence Study Comparing Pirfenidone Tablet and Capsule Dosage Forms in Healthy Adult Volunteers.

    Science.gov (United States)

    Pan, Lin; Belloni, Paula; Ding, Han Ting; Wang, Jianshuang; Rubino, Christopher M; Putnam, Wendy S

    2017-09-01

    Pirfenidone film-coated tablets were developed to offer an alternative to the marketed capsule formulation. This study assessed the bioequivalence of the tablet and capsule formulations under fed and fasted states. A Phase I, open-label, randomized, four-treatment-period, four-sequence, crossover pharmacokinetics study (NCT02525484) was conducted. Each subject received an 801-mg single dose of pirfenidone as three 267-mg capsules or one 801-mg tablet under fasted and fed conditions. Pirfenidone plasma C max , AUC 0-t and AUC 0-∞ were used to assess bioequivalence. Forty-four subjects were randomized to treatment. The 801-mg tablet in the fasted state met bioequivalence criteria [90% confidence intervals (CI) 80.00-125.00%] for the GLSM ratios of natural log-transformed C max , AUC 0-t and AUC 0-∞ . Under fed conditions, the 801-mg tablet met the bioequivalence criteria for AUC 0-t and AUC 0-∞ , but slightly exceeded the bioequivalence criteria for the C max (90% CI of 108.26-125.60%). The tablet C max was approximately 17% higher than that of the capsules. In the fed state, the tablet C max , and both AUC 0-t and AUC 0-∞ were reduced by 39% and 17%, respectively, relative to the fasted state. The tablet and capsules had acceptable tolerability profiles. The pirfenidone 801-mg tablet met bioequivalence criteria when compared with three 267-mg capsules in the fasted state. The tablet C max was slightly higher relative to capsules in the fed state, but this is not expected to have a clinically meaningful impact on the benefit-risk profile of pirfenidone. This work was supported by F. Hoffmann-La Roche Ltd.

  15. The use of tritium rich capsules with 25-35% deuterium to achieve ignition at the National Ignition Facility

    Science.gov (United States)

    Wilson, D. C.; Spears, B. K.; Hatchett, S. P., Ii; Cerjan, C. J.; Springer, P. T.; Clark, D. S.; Edwards, M. J.; Salmonson, J. D.; Weber, S. V.; Hammel, B. A.; Grim, G. P.; Herrmann, H. W.; Wilke, M. D.

    2010-08-01

    Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >~25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.

  16. The use of tritium rich capsules with 25-35% deuterium to achieve ignition at the National Ignition Facility

    International Nuclear Information System (INIS)

    Wilson, D C; Grim, G P; Herrmann, H W; Wilke, M D; Spears, B K; Ii, S P Hatchett; Cerjan, C J; Springer, P T; Clark, D S; Edwards, M J; Salmonson, J D; Weber, S V; Hammel, B A

    2010-01-01

    Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >∼25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.

  17. The use of tritium rich capsules with 25-35% deuterium to achieve ignition at the National Ignition Facility

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, D C; Grim, G P; Herrmann, H W; Wilke, M D [Los Alamos National Laboratory, Los Alamos, NM, 87545 (United States); Spears, B K; Ii, S P Hatchett; Cerjan, C J; Springer, P T; Clark, D S; Edwards, M J; Salmonson, J D; Weber, S V; Hammel, B A, E-mail: dcw@lanl.go [Lawrence Livermore National Laboratory, Livermore, CA, 94550 (United States)

    2010-08-01

    Diagnostics such as neutron yield, ion temperature, image size and shape, and bang time in capsules with >{approx}25 % deuterium fuel show changes due to burn product heating. The comparison of performance between a THD(2%) and THD(35%) can help predict ignition in a TD(50%) capsule. Surrogacy of THD capsules to TD(50%) is incomplete due to variations in fuel molecular vapour pressures. TD(25-35%) capsules might be preferred to study hot spot heating, but at the risk of increased fuel/ablator mixing.

  18. The capsule is a virulence determinant in the pathogenesis of Pasteurella multocida M1404 (B:2).

    Science.gov (United States)

    Boyce, J D; Adler, B

    2000-06-01

    Capsules from a range of pathogenic bacteria are key virulence determinants, and the capsule has been implicated in virulence in Pasteurella multocida. We have previously identified and determined the nucleotide sequence of the P. multocida M1404 (B:2) capsule biosynthetic locus (J. D. Boyce, J. Y. Chung, and B. Adler, Vet. Microbiol. 72:121-134, 2000). The cap locus consists of 15 genes, which can be grouped into three functional regions. Regions 1 and 3 contain genes proposed to encode proteins involved in capsule export, and region 2 contains genes proposed to encode proteins involved in polysaccharide biosynthesis. In order to construct a mutant impaired in capsule export, the final gene of region 1, cexA, was disrupted by insertion of a tetracycline resistance cassette by allelic replacement. The genotype of the tet(M) OmegacexA mutant was confirmed by Southern hybridization and PCR. The acapsular phenotype was confirmed by immunofluorescence, and the strain could be complemented and returned to capsule production by the presence of a cloned uninterrupted copy of cexA. Wild-type, mutant, and complemented strains were tested for virulence by intraperitoneal challenge of mice; the presence of the capsule was shown to be a crucial virulence determinant. Following intraperitoneal challenge of mice, the acapsular bacteria were removed efficiently from the blood, spleen, and liver, while wild-type bacteria multiplied rapidly. Acapsular bacteria were readily taken up by murine peritoneal macrophages, but wild-type bacteria were significantly resistant to phagocytosis. Both wild-type and acapsular bacteria were resistant to complement in bovine and murine serum.

  19. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  20. Recombination in Streptococcus pneumoniae Lineages Increase with Carriage Duration and Size of the Polysaccharide Capsule

    Science.gov (United States)

    Andam, Cheryl P.; Harris, Simon R.; Cornick, Jennifer E.; Yang, Marie; Bricio-Moreno, Laura; Kamng’ona, Arox W.; French, Neil; Heyderman, Robert S.; Kadioglu, Aras; Everett, Dean B.; Bentley, Stephen D.

    2016-01-01

    ABSTRACT Streptococcus pneumoniae causes a high burden of invasive pneumococcal disease (IPD) globally, especially in children from resource-poor settings. Like many bacteria, the pneumococcus can import DNA from other strains or even species by transformation and homologous recombination, which has allowed the pneumococcus to evade clinical interventions such as antibiotics and pneumococcal conjugate vaccines (PCVs). Pneumococci are enclosed in a complex polysaccharide capsule that determines the serotype; the capsule varies in size and is associated with properties including carriage prevalence and virulence. We determined and quantified the association between capsule and recombination events using genomic data from a diverse collection of serotypes sampled in Malawi. We determined both the amount of variation introduced by recombination relative to mutation (the relative rate) and how many individual recombination events occur per isolate (the frequency). Using univariate analyses, we found an association between both recombination measures and multiple factors associated with the capsule, including duration and prevalence of carriage. Because many capsular factors are correlated, we used multivariate analysis to correct for collinearity. Capsule size and carriage duration remained positively associated with recombination, although with a reduced P value, and this effect may be mediated through some unassayed additional property associated with larger capsules. This work describes an important impact of serotype on recombination that has been previously overlooked. While the details of how this effect is achieved remain to be determined, it may have important consequences for the serotype-specific response to vaccines and other interventions. PMID:27677790