WorldWideScience

Sample records for cea bruyeres-le-chatel

  1. Improvement of the intranuclear cascade code of Bruyeres-le-Chatel (BRIC) at low intermediate energy

    International Nuclear Information System (INIS)

    Duarte, H.

    2003-01-01

    The IntraNuclear cascade code of Bruyeres-le-Chatel called BRIC has been extended to low intermediate energy by taking in account some medium effects that are included in other nuclear dynamics models such as BUU or QMD. The results of BRIC 1.4 with the medium effects are in better agreement with experimental data than those of the first version on a wide range of incident energy, especially at low intermediate energy. We may conclude that no preequilibrium model is necessary between our INC and the deexcitation step. (orig.)

  2. Tritium research and technology facilities for fusion inside the Bruyeres-le-Chatel Research Center of the French Atomic Energy Commission

    International Nuclear Information System (INIS)

    Hircq, B.

    1990-01-01

    Because of a large tritium experience in the Bruyeres-le-Chatel Research Center (Atomic Energy Commission-FRANCE), new activities could be undertaken in 1986 inside the European Fusion Technology Program, especially tritium studies within the frame work of the Next European Torus. After presenting the general tritium research program which concerns the Torus Exhaust Gas Processing (deuterium-tritium purification and storage) and involved materials (weldability of tritium-helium containing steels and corrosion of steels by tritiated water), major obtained results are given before describing the associated equipments. (orig.)

  3. Installation and testing of the 150keV high current pulsed accelerator installed at the Service de Physique Nucleaire in Bruyeres-le-Chatel

    International Nuclear Information System (INIS)

    Dandine, Andre; Sinopoli, Louis.

    1976-01-01

    A 150keV accelerator installed at the Service de Physique Nucleaires in Bruyeres-le-Chatel is described which has been equipped especially for the preparation of the nuclear experiments carried out with the EN 7MV tandem Van de Graaff, and for the completion of totally independent experiments. Details of the ion optical arrangement and the pulsing system are presented; unanalysed beams of intensity 1 to 2mA are obtained accelerating either protons or deuterons. In the pulsed mode, at 1.25 MHz or 2.5MHz, the average intensity of the analysed beam is 8 to 10μA and the pulse length is 2ns [fr

  4. Microscopical descriptions of the fission fragmentation developed at CEA Bruyeres (France)

    International Nuclear Information System (INIS)

    Sida, J. L.

    2007-01-01

    The fission process has been studied from 1939 but there is no full theoretical description of the process. Two approaches have been developped at CEA Bruyeres le Chatel (France) in the basis of microscopic calculations with the Gogny Force. The first one is based on mean field calculations of the fission parameters (Potential enegy landscape, inertial parameters). The evolution of the wave function of the system is followed from the saddle point to the scission line in an adiabatic dynamical approach in order to determine the fission fragment distributions [GOU04]. The second one used the theoretical nuclear database AMEDEE (http://www-phynu.cea.fr/science_en_ligne/carte_potentiels_microscopiques/carte_potentiel_nucleaire.htm) which includes the mean field potential of more than 7000 nuclei. A precise energy balance is done at the scission point in order to define the available energy for each possible fragmentation. A statistical model is than used to determine the fragments distributions [HEI06]. This work is an improvement of the statistical scission point model of Wilkins et al [WIL76]. The free parameters of the previous description have been reduced to the minimum and there is still one parameter value that define the scission configuration which is not used ass a free parameter but has been fixed for the systematic that will be presented. This two microscopical models will be presented and the results will be discussed and compared to experiments. We will also point on their possible use to realize data evaluation for the burn-up of minor actinides, wastes of nuclear plants. (Author)

  5. Measurement of the ^235mU Production Cross Section Using a Critical Assembly*

    Science.gov (United States)

    Macri, Robert; Authier, Nicolas; Becker, John; Belier, Gilbert; Bond, Evelyn; Bredeweg, Todd; Glover, S.; Meot, Vincent; Rundberg, Robert; Vieira, David; Wilhelmy, Jerry

    2006-10-01

    Measurements of the creation and destruction cross sections for actinide nuclei constitute an important experimental effort in support of Stockpile Stewardship. In this talk I will give a progress report on the effort to measure the production cross section of the ^235mU isomer integrated over a fission neutron spectrum. This ongoing experiment is fielded at CEA in Valduc, France, taking advantage of the CALIBAN critical assembly. This effort is performed in collaboration with LANL, LLNL, Bruyeres le Chatel, and Valduc staff. This experiment utilizes a technique to measure internal conversion electrons from the ^235mU isomer with the French BIII detector (Bruyeres le Chatel), and involves a substantial chemistry effort (LANL) to prepare targets for irradiation and counting, as well as to remove fission fragments after irradiation. Experimental techniques will be discussed and preliminary data presented. *Work performed under the auspices of the U.S. Department of Energy by Los Alamos National Laboratory (W-7405-ENG-36) and Lawrence Livermore National Laboratory (W-7405-ENG-48), and CEA-DAM under CEA-DAM NNSA-DOE agreement.

  6. Materials aging: first predictive modeling of iron under irradiation

    International Nuclear Information System (INIS)

    Anon.

    2005-01-01

    Researchers from the CEA-Bruyeres-le-Chatel have been able to quantitatively foresee for the very first time the evolution of irradiation defects inside a structural material. Their results, obtained with iron, will contribute to better understand the aging of the materials of today's nuclear power plants and of future nuclear systems. Short paper. (J.S.)

  7. SAPhIR: a fission-fragment detector

    International Nuclear Information System (INIS)

    Theisen, Ch.; Gautherin, C.; Houry, M.; Korten, W.; Le Coz, Y.; Lucas, R.; Barreau, G.; Doan, T. P.; Belier, G.; Meot, V.; Ethvignot, Th.; Cahan, B.; Le Coguie, A.; Coppolani, X.; Delaitre, B.; Le Bourlout, P.; Legou, Ph.; Maillard, O.; Durand, G.; Bouillac, A.

    1998-01-01

    SAPhIR is the acronym for S a clay A q uitaine P ho tovoltaic cells for I s omer R e search. It consists of solar cells, used for fission-fragment detection. It is a collaboration between 3 laboratories: CEA Saclay, CENBG Bordeaux and CEA Bruyeres le Chatel. The coupling of a highly efficient fission-fragment detector like SAPhIR with EUROBALL will provide new insights in the study of very deformed nuclear matter and in the spectroscopy of neutron-rich nuclei

  8. Numerical simulation of CALIBAN reactivity perturbation experiments using neptunium-237 samples

    International Nuclear Information System (INIS)

    Humbert, Philippe; Mechitoua, Boukhmes

    2003-01-01

    In order to contribute to the validation of nuclear data used in critical mass computation, reactivity perturbation experiments using 237 Np samples have been performed at CEA-Valduc using the fast pulsed reactor CALIBAN operated in continuous mode. In this paper we report these experiments together with the numerical calculations. The calculations were carried out using PANDA, a S N code developed at CEA-Bruyeres-le-Chatel for classic criticality and stochastic neutronics applications and with MCNP4C which is a commonly used Monte Carlo code. A good agreement was found between experimental and deterministic results. (author)

  9. The CEA nuclear microprobe. Description, possibilities, application examples

    International Nuclear Information System (INIS)

    Engelmann, C.; Bardy, J.

    1986-05-01

    The nuclear microprobe installed on one of the beam lines of a 4 MV Van de Graaff located in the Research Center of Bruyeres-le-Chatel is described. The various possibilities, particularly the imaging system, and the performances of the instrument are exposed. Two typical application examples concerning, the first, the determination of the deuterium and tritium in glass microballons, the second, the detection and the localization of carbon and oxygen in the superficial layer of lithium hydride pellets, are given. Preliminary results of some other application examples are also presented. The advantages of the nuclear microprobe over the other ponctual analysis techniques are emphasized. 7 refs, 19 figs [fr

  10. The nonelastic reaction code BRIEFF and its intranuclear cascade BRIC

    International Nuclear Information System (INIS)

    Duarte, H.

    2008-01-01

    The intranuclear cascade (INC) code of Bruyeres-le-Chatel named BRIC is the first part of the nonelastic reaction code BRIEFF. Recent changes in our INC are presented. They were done for nucleon induced reaction to improve results below 100 MeV, and to calculate cross sections of compound nucleus formation. These cross sections are used in the evaporation component of our reaction code. BRIEFF is included in the Bruyeres-le-Chatel version of HETC (High Energy Transport Code) to perform thick targets calculations. BRIC has recently been incorporated into MCNPX 2.4.0 to verify thick target results of neutron yields and to do some comparisons with other nuclear models or libraries. Good agreement with data is obtained on average. (author)

  11. Turbulent FEL theory and experiment on ELSA at Bruyeres-le-Chatel

    Science.gov (United States)

    Chaix, P.; Guimbal, P.

    1995-04-01

    We consider the asymptotic behaviour of long pulse high current Compton free electron laser oscillators. It is known that if the current is high enough and the cavity losses low enough, sideband instabilities and non-linear mode couplings eventually lead to a strong broadening of the radiated spectrum, and to a strong efficiency enhancement. In this “post-sideband” regime, the electron dynamics along the wiggler is intrinsically stochastic, and the efficiency is due to chaotic diffusion of the electrons toward lower energies, rather than to standard synchrotron oscillations. This results in new scaling laws for saturation properties. We have obtained simple analytical estimates for the extracted efficiency and for the spectral width, in very good agreement with numerical simulations. The infrared ELSA free electron laser at Bruyères-le-Châtel has been used to obtain experimental evidence for these new scaling laws. In particular it has been verified that in the post-sideband regime, the ratio of the extracted efficiency to the relative spectral width is independent of the operating parameters, and close to 3/3 as predicted by theory.

  12. Progress report of the neutron and nuclear physics division for the year 1984

    International Nuclear Information System (INIS)

    1985-10-01

    This progress report gives a presentation of the nuclear physics work carried out in the Service de Physique Neutronique et Nucleaire (C.E. Bruyeres-le-Chatel) during the year 1984. It comprises a part about technical work and equipments and a second part on measurement, interpretation and evaluation of nuclear data. The third part is devoted to more theoretical works: bound state and scattering nuclear models, field theory and astrophysics [fr

  13. Experimental studies of particle acceleration with ultra-intense lasers - Applications to nuclear physics experiments involving laser-produced plasmas

    International Nuclear Information System (INIS)

    Plaisir, C.

    2010-11-01

    For the last ten years, the Ultra High Intensity Lasers offer the opportunity to produce accelerated particle beams which contain more than 10 12 electrons, protons accelerated into a few ps. We have simulated and developed some diagnostics based on nuclear activation to characterize both the angular and the energy distributions of the particle beams produced with intense lasers. The characterization methods which are presented are illustrated by means of results obtained in different experiments. We would use the particle beams produced to excite nuclear state in a plasma environment. It can modify intrinsic characteristics of the nuclei such as the half-life of some isomeric states. To prepare this kind of experiments, we have measured the nuclear reaction cross section (gamma,n) to produce the isomeric state of the 84 Rb, which has an excitation energy of 463 keV, with the electron accelerator ELSA of CEA/DIF in Bruyeres-le-Chatel (France). (author)

  14. Fission neutron output measurements at LANSCE

    International Nuclear Information System (INIS)

    Nelson, Ronald Owen; Haight, Robert C.; Devlin, Matthew J.; Fotiadis, Nikolaos; Laptev, Alexander; O'Donnell, John M.; Taddeucci, Terry N.; Tovesson, Fredrik; Ullmann, J.L.; Wender, Stephen A.; Bredeweg, T.A.; Jandel, M.; Vieira, D.J.; Wu, Ching-Yen; Becker, J.A.; Stoyer, M.A.; Henderson, R.; Sutton, M.; Belier, Gilbert; Chatillon, A.; Granier, Thierry; Laurent, Benoit; Taieb, Julien

    2010-01-01

    Accurate data for both physical properties and fission properties of materials are necessary to properly model dynamic fissioning systems. To address the need for accurate data on fission neutron energy spectra, especially at outgoing neutron energies below about 200 keV and at energies above 8 MeV, ongoing work at LANSCE involving collaborators from LANL, LLNL and CEA Bruyeres-le-Chatel is extending the energy range, efficiency and accuracy beyond previous measurements. Initial work in the outgoing neutron energy range from 1 to 7 MeV is consistent with current evaluations and provides a foundation for extended measurements. As part of these efforts, a new fission fragment detector that reduces backgrounds and improves timing has been designed fabricated and tested, and new neutron detectors are being assessed for optimal characteristics. Simulations of experimental designs are in progress to ensure that accuracy goals are met. Results of these measurements will be incorporated into evaluations and data libraries as they become available.

  15. TIERCE: A code system for particles and radiation transport in thick targets

    Energy Technology Data Exchange (ETDEWEB)

    Bersillon, O.; Bauge, E.; Borne, F.; Clergeau, J.F.; Collin, M.; Cotten, D.; Delaroche, J.P.; Duarte, H.; Flament, J.L.; Girod, M.; Gosselin, G.; Granier, T.; Hilaire, S.; Morel, P.; Perrier, R.; Romain, P.; Roux, L. [CEA, Bruyeres-le-Chatel (France). Service de Physique Nucleaire

    1997-09-01

    Over the last few years, a great effort at Bruyeres-le-Chatel has been the development of the TIERCE code system for the transport of particles and radiations in complex geometry. The comparison of calculated results with experimental data, either microscopic (double differential spectra, residual nuclide yield...) or macroscopic (energy deposition, neutron leakage...), shows the need to improve the nuclear reaction models used. We present some new developments concerning data required for the evaporation model in the framework of a microscopic approach. 22 refs., 6 figs.

  16. Progress report of the Neutron and Nuclear Physics Division for the year 1981

    International Nuclear Information System (INIS)

    1982-05-01

    This progress report gives a presentation of the nuclear physics work carried out in the Service de Physique Neutronique et Nucleaire (C.E. Bruyeres-le-Chatel) during the year 1981. It comprises a part about technical work and equipments and a second part on experiments and their interpretations. The third part is devoted to nuclear data evaluations and processing along with theoretical work. At the end of the report a list is given of the documents issued during the year 1981 and a list of talks given in the laboratory [fr

  17. Tritium tasks for the net fusion technology program

    International Nuclear Information System (INIS)

    Hircq, B.

    1990-01-01

    Six Tritium Technology tasks have been undertaken in the BRUYERES-LE-CHATEL Research Center of the French Atomic Energy Commission, in June 1986, as part of the NET Tritium Technology Program. Four of these six studies concern the torus exhaust gas purification and two of them are more specific of the involved materials. In 1988, the studies themselves have begun and the objective of this document is to indicate, for each task, the main results which have been obtained during the period 1988-89, for allowing a global valuation of the progress state as well as an anticipation for carrying out the works

  18. Status of (n,2n) cross section measurements at Bruyeres-le-Chatel

    International Nuclear Information System (INIS)

    Frehaut, J.; Bertin, A.; Bois, R.; Jary, J.

    1980-05-01

    Cross sections for the (n,2n) reactions have been measured between threshold and 15 MeV for about 50 elements and separated isotopes using the large gadolinium-loaded liquid scintillator method and the 7 MV tandem Van de Graaff accelerator as a pulsed neutron source. The (n,2n) cross sections have been normalized to the fission cross section of 238 U; they are obtained with a relative accuracy of 4% to 10%. The systematic trends of the data obtained on series of separated isotopes are discussed, and some comparaisons with statistical model calculations are presented

  19. Implementation of neural networks on 'Connection Machine'

    International Nuclear Information System (INIS)

    Belmonte, Ghislain

    1990-12-01

    This report is a first approach to the notion of neural networks and their possible applications within the framework of artificial intelligence activities of the Department of Applied Mathematics of the Limeil-Valenton Research Center. The first part is an introduction to the field of neural networks; the main neural network models are described in this section. The applications of neural networks in the field of classification have mainly been studied because they could more particularly help to solve some of the decision support problems dealt with by the C.E.A. As the neural networks perform a large number of parallel operations, it was therefore logical to use a parallel architecture computer: the Connection Machine (which uses 16384 processors and is located at E.T.C.A. Arcueil). The second part presents some generalities on the parallelism and the Connection Machine, and two implementations of neural networks on Connection Machine. The first of these implementations concerns one of the most used algorithms to realize the learning of neural networks: the Gradient Retro-propagation algorithm. The second one, less common, concerns a network of neurons destined mainly to the recognition of forms: the Fukushima Neocognitron. The latter is studied by the C.E.A. of Bruyeres-le-Chatel in order to realize an embedded system (including hardened circuits) for the fast recognition of forms [fr

  20. ECISVIEW. An interactive toolbox for optical model development

    International Nuclear Information System (INIS)

    Koning, A.J.; Van Wijk, J.J.; Delaroche, J.P.

    1997-09-01

    The software package ECISVIEW is a graphical interface built around the multi-disciplinary nuclear reaction code ECIS-95. The basic purpose of ECISVIEW is the possibility to change optical potential parameters interactively, with the keyboard or the mouse, and to display the calculated result immediately on the screen. The key feature of the working method is that the user can specify the value of optical potential parameters as any mathematical function of the energy, A, Z or user defined parameters. This enables us to obtain conveniently the optimal optical potential parameters for a given nucleus over the whole energy region of interest. ECISVIEW makes it possible to simultaneously study the dependence of all calculated angular distributions, polarizations and total cross sections on optical model parameters. This method is perhaps more than 100 times faster than the conventional method of preparing an input file, running the code, editing the output file and finally viewing the data with a graphical program. ECISVIEW has been developed at ECN in Petten, Netherlands, and has been extensively used at CEA, Bruyeres-le-Chatel, France. A spherical 0-200 MeV nucleon optical model for 90 Zr is presented as an example. 4 figs., 1 tab., 5 refs

  1. Fission neutron spectra measurements at LANSCE - Status and plans

    International Nuclear Information System (INIS)

    Haight, R. C.; Noda, S.; Nelson, R. O.; O'Donnell, J. M.; Devlin, M.; Chatillon, A.; Granier, T.; Taiebb, J.; Laurent, B.; Belier, G.; Becker, J. A.; Wu, C. Y.

    2010-01-01

    A program to measure fission neutron spectra from neutron-induced fission of actinides is underway at the Los Alamos Neutron Science Center (LANSCE) in a collaboration among the CEA laboratory at Bruyeres-le-Chatel, Lawrence Livermore National Laboratory and Los Alamos National Laboratory. The spallation source of fast neutrons at LANSCE is used to provide incident neutron energies from less than 1 MeV to 100 MeV or higher. The fission events take place in a gas-ionization fission chamber, and the time of flight from the neutron source to that chamber gives the energy of the incident neutron. Outgoing neutrons are detected by an array of organic liquid scintillator neutron detectors, and their energies are deduced from the time of flight from the fission chamber to the neutron detector. Measurements have been made of the fission neutrons from fission of 235 U, 238 U, 237 Np and 239 Pu. The range of outgoing energies measured so far is from 0.7 MeV to approximately 8 MeV. These partial spectra and average fission neutron energies are compared with evaluated data and with models of fission neutron emission. Results to date are summarized in this presentation. Future plans are to make significant improvements in the fission chambers, neutron detectors, signal processing, data acquisition and the experimental environment to provide high fidelity data including measurements of fission neutrons below 0.7 MeV and improvements in the data above 8 MeV. (authors)

  2. Management of slightly tritiated wastes and associated tests at the Study Center of Bruyeres le Chatel

    International Nuclear Information System (INIS)

    Paillard, P.; Clerc, H.

    1991-01-01

    Daily degassing rate of drums containing wastes with a low tritium content is a required parameter for removal towards a storage site. Methodology and techniques of increasing sensitivity used for this rate measurement are presented. For 200-liter drums, the degassing range is comprised between 0.1 MBq and 1.85 GBq per day. Equipment has been operating for several years allowing the dispatching of 443 drums and also the testing of on-site storage before disposal

  3. Recapitulative list of the C.E.A. reports published by the French Atomic Energy Commission (n.757-1062, december 1957-december 1958) supplement to C.E.A. reports n. 593 and 756; Liste recapitulative des rapports C.E.A. publies par le Commissariat a l'Energie Atomique (du n.757 a 1062, decembre 1957-decembre 1958) complement aux rapports C.E.A. n. 593 et 756

    Energy Technology Data Exchange (ETDEWEB)

    Schmiterlow, C G; Cohen, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Recapitulative list of the C.E.A. reports published by the French Atomic Energy Commission. (number 757-1062, december 1957 - december 1958). Supplement to C.E.A. reports number 593 and 756. (author) [French] Liste recapitulative des rapports C.E.A. publies par le Commissariat a l'Energie Atomique (du numero 757 au numero 1062, decembre 1957 - decembre 1958). Complement aux rapports C.E.A. numero 593 et 756. (auteur)

  4. Savannah River Laboratory contribution to the Chalk River experimental HT release of June 1987

    International Nuclear Information System (INIS)

    Murphy, C.E. Jr.

    1987-01-01

    Seventeen years ago, a series of experiments were conducted at Bruyeres-Le-Chatel by French scientists interested in atmospheric diffusion. The scientists used tritium as a tracer in these tests. The results showed nearly complete oxidation of the gas by the time the released material had been carried 10 kilometers from the source. It became clear that if the results were general, the doses projected for fusion reactors would be greatly increased over what had been expected from earlier experience with HT gas. For this reason, the Next European Torus (NET) fusion program funded a series of experiments to look further at tritium oxidation in the environment. SRL participation in the tests provided an opportunity to make field comparisons of the SRL design tritium gas samplers and also provided vegetation that had been exposed under controlled conditions which could be used to study the incorporation of tritium into vegetation organics, the subject of ongoing SRL research. 25 refs., 4 figs., 2 tabs

  5. Fission neutron spectra measurements at LANSCE - status and plans

    International Nuclear Information System (INIS)

    Haight, Robert C.; Noda, Shusaku; Nelson, Ronald O.; O' Donnell, John M.; Devlin, Matt; Chatillon, Audrey; Granier, Thierry; Taieb, Julien; Laurent, Benoit; Belier, Gilbert; Becker, John A.; Wu, Ching-Yen

    2009-01-01

    A program to measure fission neutron spectra from neutron-induced fission of actinides is underway at the Los Alamos Neutron Science Center (LANSCE) in a collaboration among the CEA laboratory at Bruyeres-le-Chatel, Lawrence Livermore National Laboratory and Los Alamos National Laboratory. The spallation source of fast neutrons at LANSCE is used to provide incident neutron energies from less than 1 MeV to 100 MeV or higher. The fission events take place in a gas-ionization fission chamber, and the time of flight from the neutron source to that chamber gives the energy of the incident neutron. Outgoing neutrons are detected by an array of organic liquid scintillator neutron detectors, and their energies are deduced from the time of flight from the fission chamber to the neutron detector. Measurements have been made of the fission neutrons from fission of 235 U, 238 U, 237 Np and 239 Pu. The range of outgoing energies measured so far is from 1 MeV to approximately 8 MeV. These partial spectra and average fission neutron energies are compared with evaluated data and with models of fission neutron emission. Results to date will be presented and a discussion of uncertainties will be given in this presentation. Future plans are to make significant improvements in the fission chambers, neutron detectors, signal processing, data acquisition and the experimental environment to provide high fidelity data including mea urements of fission neutrons below 1 MeV and improvements in the data above 8 MeV.

  6. Decontamination and dismantling at the CEA; L'assainissement et le demantelement au CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This document presents the dismantling policy at the CEA (French Research Center on the atomic energy), the financing of the decontamination and the dismantling, the regulatory framework, the knowledge and the technology developed at the CEA, the radiation protection, the environment monitoring and the installations. (A.L.B.)

  7. Elaboration of an alpha-numeric classification for file of matters of the documentation service of the CEA; Elaboration d'une classification alfha-numerique pour le fichier matieres du service de documentation du Commissariat a l'Energie Atomique

    Energy Technology Data Exchange (ETDEWEB)

    Braffort, P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    We give the principles of a classification of matters to square basis, suiting the needs of the Service, of Documentation of the C.E.A. We present the detail of the categories in the order of the 'columns', likewise the big scientific subdivisions at the CEA. (authors) [French] On donne les principes d'une classification matieres a base carree, convenant aux besoins du Service de Documentation du C.E.A. On presente ensuite le detail des rubriques dans l'ordre des ''colonnes'', c'est-a-dire, des grandes subdivisions scientifiques du C.E.A. (auteurs)

  8. Results of the systematic study of neutron dosimeters and neutron radiometers responses from Bruyeres and Valduc's experiments

    International Nuclear Information System (INIS)

    Pras, Ph.; Ledoux, X.; Patin, Y.

    1999-01-01

    This document gives the results of the systematic study of neutron dosimeters (Bubbles detectors) and neutron radiometers (Cramal, Nausicaa, EGG Lb6411) with standard sources and with the Bruyeres Van de Graaff 4MV accelerator. The dose equivalent rate response as a function of the neutron energy is parameterized. Even for low dose equivalent rate, a good reproducibility of the measurements is found in the strict respect of a given method. The response of the different systems is independent of the dose equivalent rate. (author)

  9. Nuclear. In China, the CEA asserts itself as a team leader; Nucleaire: en Chine, le CEA s'impose en meneur de jeu

    Energy Technology Data Exchange (ETDEWEB)

    Dupin, L.

    2011-03-15

    As the French government gave the CEA the responsibility of negotiating the nuclear French-Chinese nuclear strategic partnership, this article outlines the personality of the CEA's chairman, Bernard Bigot, but also the tensions which exist between the two main actors of the French nuclear industry, EDF and Areva, notably about their respective projects of development of a new reactor with China as far as EDF is concerned, and with Japan as far as Areva is concerned. In fact, China is asking France, not to build new reactors but to improve the performance and the safety in the existing ones

  10. Overview of CEA research in the field of radionuclides migration; Syntheses des recherches menees par le CEA sur la migration des radionucleides

    Energy Technology Data Exchange (ETDEWEB)

    Poinssot, Ch; Trotignon, L; Tevissen, E

    2006-07-01

    This report presents a synthetic status of the researches conducted within the Nuclear Energy Division (CEA/DEN) in the field of radionuclides migration in three specific areas which have been chosen for their representativeness and potential impact: the migration of RN in PWR reactors, the migration of RN from a deep geological repository and the migration processes in the surface environments. In addition, some status is given about more generic research which is conducted in the field of RN speciation in the aqueous phase and at the interfaces and regarding chemistry / transport couplings. Additional information about the human and technical means involved in these fields of research in CEA/DEN is finally given in the Appendix. (authors)

  11. Study of the structure of light neutron rich nucleus with the Tonnerre array

    International Nuclear Information System (INIS)

    Pietri, St.

    2003-06-01

    This work concern the technical development made on the multidetector TONNERRE and the study of the 34 Si nucleus by a complete beta-neutron-gamma spectroscopy. In the first part various tests performed on modules of the detector in the 'Centre d'Etude de Bruyere le Chatel' are presented. A modification of the embassies of the photomultipliers tubes allows to gain more than 50% in the neutron efficiency and to obtain a threshold lower than 300 keV for the neutron energy. A complete C++ simulation of the neutron propagation in the array was carried out. It explains that the slow component of the light output of the scintillator may be responsible of the shape of the time-of-flight spectrum. The second part of these report presents the experiment devoted to the study of the structure of the 34 Si from the beta decay of the 34 Al. It was performed at the GANIL facility using the TONNERRE array and germanium of ENOGAM. The 34 Al was produced by projectile fragmentation of a 36 S beam of 50 MeV/A in a target of 9 Be. A complete beta scheme of the 34 Al is proposed. Eight neutron lines following the 34 Al decay were observed for the first time. Finally we suggest that a monopolar transition could occur in the 34 Si nucleus signing a O + 2 state at 2133 keV. (author)

  12. CEA Annual report 2007; CEA rapport annuel 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The CEA, a prominent player in research development and innovation, is active in three main domains: energy, health care and information technology, defense and security. This annual report presents the CEA activities for the year 2007 in these three main areas: science and technology working for nuclear deterrence and global security, the energies without greenhouse effect gases emission against the climatic change, researches in the information sciences and technologies for a better communication and health. The CEA safety, organization, communication and international relations are also presented. (A.L.B.)

  13. CEA sustainable development report 2007; CEA rapport developpement durable 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The CEA, a prominent player in research development and innovation, is active in three main domains: energy, health care and information technology, defense and security. This annual report presents the CEA activities in the domain of the sustainable development. The first part is devoted to the environment preservation policy (energy, water, air, chemistry, wastes, transport, buildings). The second part shows the dynamic governance in the domain of the risks management. The last part presents the CEA activities of research for the sustainable development. (A.L.B.)

  14. The CEA and the alternative energies. Press tour 25 and 26 november 1999; Le CEA et les energies alternatives. Voyage de presse les 25 et 26 novembre 1999

    Energy Technology Data Exchange (ETDEWEB)

    Carola, G. [CEA/Grenoble, 38 (France); Ngo, Ch. [CEA, Dir. de la Strategie et de l' Evaluation, 75 - Paris (France); Mermilliod, N.; Serre-Combe, P. [CEA/Grenoble, Dir. des Technologies Avancees, DTA, 38 (France); Sanglan, P. [Air Liquide, 38 - Sassenage (France); De La Graviere, M. [CEA/Cadarache, 13 - Saint-Paul-lez-Durance (France); Dieudonne, O.; Malbranche, Ph. [CEA/Cadarache, Dir. des Reacteurs Nucleaires, DRN, 13 - Saint-Paul-lez-Durance (France)

    1999-11-01

    In the framework of the public information on the CEA center of Cadarache and Grenoble, a presentation of the researches concerning the alternative energies is proposed. The Cea is commissioned by the Public Authorities, to keep the nuclear option open and for the long-dated, to develop renewable energies. In this domain researches on fuel cells and photovoltaic solar energy are performed. The principle and the applications of the fuel cell and the photovoltaic are recalled to introduce the research programs and the partners. (A.L.B.)

  15. Study of the structure of light neutron rich nucleus with the Tonnerre array; Etude de la structure de noyaux legers riches en neutrons a l'aide du multidetecteur Tonnerre

    Energy Technology Data Exchange (ETDEWEB)

    Pietri, St

    2003-06-01

    This work concern the technical development made on the multidetector TONNERRE and the study of the {sup 34}Si nucleus by a complete beta-neutron-gamma spectroscopy. In the first part various tests performed on modules of the detector in the 'Centre d'Etude de Bruyere le Chatel' are presented. A modification of the embassies of the photomultipliers tubes allows to gain more than 50% in the neutron efficiency and to obtain a threshold lower than 300 keV for the neutron energy. A complete C++ simulation of the neutron propagation in the array was carried out. It explains that the slow component of the light output of the scintillator may be responsible of the shape of the time-of-flight spectrum. The second part of these report presents the experiment devoted to the study of the structure of the {sup 34}Si from the beta decay of the {sup 34}Al. It was performed at the GANIL facility using the TONNERRE array and germanium of ENOGAM. The {sup 34}Al was produced by projectile fragmentation of a {sup 36}S beam of 50 MeV/A in a target of {sup 9}Be. A complete beta scheme of the {sup 34}Al is proposed. Eight neutron lines following the {sup 34}Al decay were observed for the first time. Finally we suggest that a monopolar transition could occur in the {sup 34}Si nucleus signing a O{sup +}{sub 2} state at 2133 keV. (author)

  16. 1999 scientific evaluation at the CEA; L'evaluation scientifique 1999 au CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This report presents a statement of the scientific and technical activity of the French atomic energy commission (CEA) for the year 1999. This evaluation is made by external and independent experts and requires some specific dispositions for the nuclear protection and safety institute (IPSN) and for the direction of military applications (DAM). The report is divided into 4 parts dealing successively with: 1)the CEA, a public research organization (strategy, research programs, new organization of the CEA activities, civil nuclear research, technology research and transfer, defence activities, transfer of knowledge) 2)the scientific evaluation at the CEA (evaluations of the civil applications of the CEA, IPSN, DAM, INSTN (national institute for nuclear sciences and techniques) 3)synthesis of the 1999 scientific and technical evaluation for each operational directions of the CEA (directions of fuel cycle, of nuclear reactors, of advanced technologies, of materials sciences, of life sciences, of military applications, of the nuclear protection and safety institute and of the national institute for nuclear sciences and techniques) 4)the corresponding members of the evaluation and the list of scientific and technical councils and members.

  17. Immunological comparison of ovarian and colonic CEA

    International Nuclear Information System (INIS)

    Burtin, P.; Gendron, M.C.; Maunoury, M.T.; Lamerz, R.; Schnabel, G.

    1982-01-01

    Ovarian and colonic CEA were compared immunologically by means of antisera prepared against each of them. CEAs of both origins were found identical by immunodiffusion methods. In radioimmunological experiments, slight differences were observed between some but not all ovarian CEAs and colonic CEAs and also between different preparations of colonic CEA: no organ specificity of ovarian CEA could be demonstrated. Finally, CEA level was measured in 41 sera of patients with ovarian carcinoma by two radioimmunoassays, one using colonic CEA as tracer and standard and anti-colonic CEA serum, the other using ovarian CEA and anti-ovarian CEA serum: the values given by the two assays were highly correlated (rsub(s) = 0.8107), meaning that an organ specific assay for ovarian CEA is not needed. (Auth.)

  18. Frequency Dependence and Spatial Distribution of Seismic Attenuation in France: Experimental Results and Possible Interpretations

    Science.gov (United States)

    1989-09-12

    and possible interpretations. M. Campillo Laboratoire de Geophysique Interne et Tectonophysique Universite Joseph Fourier and Observatoire de Grenoble...IRIGM, BP 53X, 38041 Grenoble, France J.L. Plantet Laboratoire de Detection Geophysique Commissariat a l’Energie Atomique BP 12, 91680 Bruyere-le

  19. 1999 scientific evaluation at the CEA; L'evaluation scientifique 1999 au CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    This report presents a statement of the scientific and technical activity of the French atomic energy commission (CEA) for the year 1999. This evaluation is made by external and independent experts and requires some specific dispositions for the nuclear protection and safety institute (IPSN) and for the direction of military applications (DAM). The report is divided into 4 parts dealing successively with: 1)the CEA, a public research organization (strategy, research programs, new organization of the CEA activities, civil nuclear research, technology research and transfer, defence activities, transfer of knowledge) 2)the scientific evaluation at the CEA (evaluations of the civil applications of the CEA, IPSN, DAM, INSTN (national institute for nuclear sciences and techniques) 3)synthesis of the 1999 scientific and technical evaluation for each operational directions of the CEA (directions of fuel cycle, of nuclear reactors, of advanced technologies, of materials sciences, of life sciences, of military applications, of the nuclear protection and safety institute and of the national institute for nuclear sciences and techniques) 4)the corresponding members of the evaluation and the list of scientific and technical councils and members.

  20. Cutoff Values of Serum Carcinoembryonic Antigen (CEA) in Normal Korean Adults and Factors Influencing Serum CEA Level

    International Nuclear Information System (INIS)

    Kim, Jong Soon; Kim, Sun Wook; Chung, June Key; Lee, Dong Soo

    1994-01-01

    Carcinoembryonic Antigen is one of most frequently checked tumor markers in cancer management. We performed statistical analysis with serum CEA data of 2626 persons who received regular health examination and were thought to be free of active disease to determine the cutoff values of serum CEA level in normal Korean adults and to study the factors influencing serum CEA levels in normal subjects. 1) The cutoff values of serum CEA in normal Korean adults in general were 9.28 ng/ml for men, 5.90 ng/ml for women. 2) Serum CEA level was influenced by age, present smoking history, sex, and abnormal findings in chest X ray. 3) Serum CEA level had no correlation with the history of amount of alcohol consumption or obesity. 4) Cutoff values of serum CEA in normal Korean adults were tabulated according to age, sex, and smoking history. Serum CEA level was influenced by age, sex, present smoking history and abnormal findings in chest X ray and cutoff values of serum CEA were tabulated according to age, sex, and smoking history.

  1. Carcinoembryonic antigen (CEA) level, CEA ratio, and treatment outcome of rectal cancer patients receiving pre-operative chemoradiation and surgery

    International Nuclear Information System (INIS)

    Yang, Kai-Lin; Chang, Shih-Ching; Chu, Lee-Shing; Wang, Ling-Wei; Yang, Shung-Haur; Liang, Wen-Yih; Kuo, Ying-Ju; Lin, Jen-Kou; Lin, Tzu-Chen; Chen, Wei-Shone; Jiang, Jeng-Kae; Wang, Huann-Sheng

    2013-01-01

    To investigate serum carcinoembryonic antigen (CEA) as a prognostic factor for rectal cancer patients receiving pre-operative chemoradiotherapy (CRT). Between 2000 and 2009, 138 patients with advanced rectal cancer receiving CRT before surgery at our hospital were retrospectively classified into 3 groups: pre-CRT CEA <6 ng/ml (group L; n = 87); pre-CRT CEA ≥ 6 ng/ml and post-CRT CEA <6 ng/ml (group H-L; n = 32); and both pre- and post-CRT CEA ≥ 6 ng/ml (group H-H; n = 19). CEA ratio (defined as post-CRT CEA divided by pre-CRT CEA), post-CRT CEA level and other factors were reviewed for prediction of pathologic complete response (pCR). Five-year disease-free survival (DFS) was better in groups L (69.0%) and H-L (74.5%) than in group H-H (44.9%) (p = 0.024). Pathologic complete response was observed in 19.5%, 21.9% and 5.3% of groups L, H-L and H-H respectively (p = 0.281). Multivariate analysis showed that ypN stage and pCR were independent prognostic factors for DFS and that post-CRT CEA level was independently predictive of pCR. As a whole, post-CRT CEA <2.61 ng/ml predicted pCR (sensitivity 76.0%; specificity 58.4%). For those with pre-CRT CEA ≥6 ng/ml, post-CRT CEA and CEA ratio both predicted pCR (sensitivity 87.5%, specificity 76.7%). In patients with pre-CRT serum CEA ≥6 ng/ml, those with “normalized” CEA levels after CRT may have similar DFS to those with “normal” (<6 ng/ml) pre-CRT values. Post-CRT CEA level is a predictor for pCR, especially in those with pre-CRT CEA ≥6 ng/ml

  2. CEA 2005 annual report; CEA rapport annuel 2005

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This document is the 2005 activity report of the French atomic energy commission (CEA). The CEA is a main actor of nuclear research, development and innovation and is involved in three main domains: energy, defense/security, and information/health technologies thanks to high quality research works. With a manpower of 15000 researchers and collaborators with internationally acknowledged competences, the CEA is a driving force of industrial innovation and develops partnerships with French and European industries. It also warrants the perenniality of nuclear dissuasion. This report presents these different aspects of the CEA activities: 1 - defense-security: simulation program, opening to the scientific community, nuclear warheads, nuclear propulsion, cleansing of Rhone valley facilities, permanent monitoring of treaties respect, fight against terrorism; 2 - energy: optimization of the industrial park, advances in long lived radioactive wastes management, future nuclear systems, cleansing and dismantling integration, European nuclear energy research, new energy technologies; 3 - information and health technologies: major challenge of micro- and nano-technologies, key role of software technologies and complex systems; 4 - big research facilities opened to the scientific and industrial communities; 5 - scientific status: scientific evaluation process, prices and honors; 6 - programs support: revisited strategic control, confirmed simplification, active employment and training policy, teaching and training, technological valorization, international relations, communication, continuous quality approach, mastery of facilities safety, security, environmental control, a key-year for information systems. A financial report is attached to the document. (J.S.)

  3. The great Cea actors

    International Nuclear Information System (INIS)

    Frejacques, C.

    1997-01-01

    With the Claude Frejacques life it is a Cea passage that we find. He began the studies on uranium isotope separation. He developed and saw to a successful conclusion these researches at Cea during twenty five years and extended his sphere of operations to the whole fuel cycle, from upstream to downstream. Director of research at the Cea, he was also D.G.R.S.T. director and during eight years President of the C.N.R.S. (N.C.)

  4. Scientific evaluation at the CEA; Evaluation scientifique au CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    This report presents a statement of the scientific and technical activity of the French atomic energy commission (CEA) for the year 1998. This evaluation is made by external and independent experts and requires some specific dispositions for the nuclear protection and safety institute (IPSN) and for the direction of military applications (DAM). The report is divided into 5 parts dealing successively with: part 1 - the CEA, a public research organization (civil nuclear research, technology research and transfers, defence activities); the scientific and technical evaluation at the CEA (general framework, evaluation of the IPSN and DAM); part 2 - the scientific and technical councils (directions of fuel cycle, of nuclear reactors, and of advanced technologies); part 3 - the scientific councils (directions of matter and of life sciences); the nuclear protection and safety institute; the direction of military applications; part 4 - the corresponding members of the evaluation; part 5 - the list of scientific and technical councils and members. (J.S.)

  5. CEA Annual report 2007

    International Nuclear Information System (INIS)

    2007-01-01

    The CEA, a prominent player in research development and innovation, is active in three main domains: energy, health care and information technology, defense and security. This annual report presents the CEA activities for the year 2007 in these three main areas: science and technology working for nuclear deterrence and global security, the energies without greenhouse effect gases emission against the climatic change, researches in the information sciences and technologies for a better communication and health. The CEA safety, organization, communication and international relations are also presented. (A.L.B.)

  6. Reactivity effect breakdown calculations with deterministic and stochastic perturbations analysis – JEFF-3.1.1 to JEFF3.2T1 (BRC-2009 actinides application

    Directory of Open Access Journals (Sweden)

    Morillon B.

    2013-03-01

    Full Text Available JEFF-3.1.1 is the reference nuclear data library in CEA for the design calculations of the next nuclear power plants. The validation of the new neutronics code systems is based on this library and changes in nuclear data should be looked at closely. Some new actinides evaluation files at high energies have been proposed by CEA/Bruyères-le-Chatel in 2009 and have been integrated in JEFF3.2T1 test release. For the new release JEFF-3.2, CEA will build new evaluation files for the actinides, which should be a combination of the new evaluated data coming from BRC-2009 in the high energy range and improvements or new evaluations in the resolved and unresolved resonance range from CEA-Cadarache. To prepare the building of these new files, benchmarking the BRC-2009 library in comparison with the JEFF-3.1.1 library was very important. The crucial points to evaluate were the improvements in the continuum range and the discrepancies in the resonance range. The present work presents for a selected set of benchmarks the discrepancies in the effective multiplication factor obtained while using the JEFF-3.1.1 or JEFF-3.2T1 library with the deterministic code package ERANOS/PARIS and the stochastic code TRIPOLI-4. They have both been used to calculate cross section perturbations or other nuclear data perturbations when possible. This has permittted to identify the origin of the discrepancies in reactivity calculations. In addition, this work also shows the importance of cross section processing validation. Actually, some fast neutron spectrum calculations have led to opposite tendancies between the deterministic code package and the stochastic code. Some particular nuclear data (MT=5 in ENDF terminology seem to be incompatible with the current MERGE or GECCO processing codes.

  7. [Significance of CEA in gastric and colorectal cancer].

    Science.gov (United States)

    Uehara, K; Miyamoto, Y; Izuo, M; Shiozaki, H; Aiba, S; Matsumoto, H

    1985-04-01

    The determination of serum CEA (Sandwich method) and CEA staining (PAP method) of excised specimens were performed in patients with gastric or colorectal cancer, and the biological characteristics of each cancer and the factors to increase serum CEA were studied with the following results: As colonic cancer has strong CEA productivity, serum CEA can be useful for the detection of cancer, and especially effective for the postoperative observation. Gastric cancer has weak CEA productivity, and serum CEA is not so useful in the detection of cancer and the judgement of resectability. The CEA positive rate of tissue with CEA staining was 80% in gastric cancer, 100% in colonic cancer, and were nearly equal to the CEA positive rate of serum in the group of terminal stage. In the mode of CEA staining of cancerous cells, IV type was observed most frequently in gastric cancer, and I type in colonic cancer. Among the resected cases showing more than 7ng/ml serum CEA, differentiated type, lymph node metastasis (+), the degree of tissue staining with CEA staining, the mode of cell staining O or I type in gastric cancer and I type in colonic cancer were observed in common.

  8. CEA and its radioactive wastes

    International Nuclear Information System (INIS)

    Marano, S.

    1999-01-01

    CEA annually produces about 3500 tons of radioactive wastes in its 43 basic nuclear installations. CEA ranks third behind EDF and Cogema. Low-level wastes (A wastes) are sent to ANDRA (national agency for the management of nuclear wastes)whereas medium-level wastes (B wastes) are stored by CEA itself. CEA has checked off its storing places and has set up an installation Cedra to process and store ancient and new nuclear wastes. 3 other installations are planned to operate within 6 years: Agate (Cadarache) will treat liquid effluents, Stella (Saclay) will process liquid wastes that are beta or gamma emitters, and Atena (Marcoule) will treat and store radioactive sodium coming from Phenix reactor and IPSN laboratories. The use of plasma torch for vitrifying wastes is detailed, the management of all the nuclear wastes produced by CEA laboratories and installations is presented. (A.C.)

  9. CEA - Annual report 2006; CEA - Rapport annuel 2006

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    The CEA, a prominent player in research development and innovation, is active in 3 main areas: energy, health care and information technology and defense and security. This annual report presents the CEA activity for the year 2006 in these three main areas: Science and technology working for nuclear deterrence and global security (the simulation programs, the nuclear warheads, the nuclear propulsion, the decommissioning, the fighting against nuclear proliferation and monitoring international treaties, the global security); health and information technology (micro and nano technologies and systems); energy from nuclear fission and fusion and other technologies that do not emit greenhouse gases (progress for the nuclear industry, sustainable management of radioactive materials and waste, nuclear systems of the future, new energy technologies). (A.L.B.)

  10. Reagents for radioimmunological determination of carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Albert, Z.; Balbierz, H.; Breberowicz, J.

    1978-01-01

    The work was undertaken to prepare the reagents for carcinoembryonic antigen (CEA) radioimmunoassay with double antibody method. The CEA standard of high immunoreactivity was prepared and purified. The purified CEA was used for immunozation of goats. The goat anti - CEA sera were received. IgG fraction from normal goat serum was purified and used for the production of horse anti-goat IgG serum which was then used in the radioimmunoassay of CEA. The labelling of CEA with iodine-125 has been carried out be means of the enzymatic method.(Z.R.)

  11. CEA sustainable development report 2007

    International Nuclear Information System (INIS)

    2007-01-01

    The CEA, a prominent player in research development and innovation, is active in three main domains: energy, health care and information technology, defense and security. This annual report presents the CEA activities in the domain of the sustainable development. The first part is devoted to the environment preservation policy (energy, water, air, chemistry, wastes, transport, buildings). The second part shows the dynamic governance in the domain of the risks management. The last part presents the CEA activities of research for the sustainable development. (A.L.B.)

  12. Radioimmunodetection of colorectal cancer, using anti-CEA monoclonal antibodies

    International Nuclear Information System (INIS)

    Murayama, Hiroki; Watanabe, Tadashi; Tadokoro, Masanori; Takagi, Hiroshi; Sakuma, Sadayuki; Sakamoto, Junichi.

    1989-01-01

    Aiming at radioimmunodetection of colorectal cancer, anti-CEA monoclonal antibodies (CEA102) were produced by immunization with purified CEA. CEA102 showed high specificity with clorectal cancer by mixed hemadsorption assay and immunoperoxidase technique. The antigen detected by CEA102 was confirmed to be carcinoembryonic antigen (CEA) and its molecular weight was estimated to be ca. 180,000 by biochemical analysis. The in vivo study using nude mice grafted a human colorectal cancer or a human malignant melanoma showed greater accumulation of 125 I-labeled CEA102 in CEA-positive colorectal cancer than in nude mouse tissues and CEA-negative malignant melanoma. Moreover we successfully obtained scans with good localization of the grafted colorectal cancer on FCR (Fuji Computed Radiography). Using 131 I-labeled CEA102 liver metastasis in the patient with colorectal cancer was successfully detected by external scanning with γ-camera. These results suggest that radiolabeled CEA102 is useful for the detection of colorectal cancer. (author)

  13. CEA - Risk control report 2014

    International Nuclear Information System (INIS)

    Verwaerde, Daniel; Bonnevie, Edwige; Maillot, Bernard

    2015-06-01

    After introductory presentations by CEA managers in charge of risk management and controls, this document presents and comments the actions undertaken by the CEA and the obtained results in terms of risk management in different fields: environment protection and control, facilities safety, health and radiation protection, transport of hazardous materials, waste management, sites protection, installations and assets, emergency response, legal risk management, internal inspections and audits. Other topics are addressed like the presentation of the risk control sector, and the role of the CEA in the relationship between research and industry

  14. 1999 scientific evaluation at the CEA

    International Nuclear Information System (INIS)

    1999-01-01

    This report presents a statement of the scientific and technical activity of the French atomic energy commission (CEA) for the year 1999. This evaluation is made by external and independent experts and requires some specific dispositions for the nuclear protection and safety institute (IPSN) and for the direction of military applications (DAM). The report is divided into 4 parts dealing successively with: 1)the CEA, a public research organization (strategy, research programs, new organization of the CEA activities, civil nuclear research, technology research and transfer, defence activities, transfer of knowledge) 2)the scientific evaluation at the CEA (evaluations of the civil applications of the CEA, IPSN, DAM, INSTN (national institute for nuclear sciences and techniques) 3)synthesis of the 1999 scientific and technical evaluation for each operational directions of the CEA (directions of fuel cycle, of nuclear reactors, of advanced technologies, of materials sciences, of life sciences, of military applications, of the nuclear protection and safety institute and of the national institute for nuclear sciences and techniques) 4)the corresponding members of the evaluation and the list of scientific and technical councils and members

  15. CEA financial report 2007; CEA rapport financier 2007

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This document provides financial data on the CEA for the year 2007. The management report (budget, resources, expenditures) and the accounting are detailed. The main management events of the year 2007 are presented. (A.L.B.)

  16. CEA - 2014 risk management assessment

    International Nuclear Information System (INIS)

    Bonnevie, Edwige; Verwaerde, Daniel; Maillot, Bernard

    2015-06-01

    After introducing presentations of CEA managers in charge of risk management and controls, this document presents and comments the actions undertaken by the CEA and the obtained results in terms of risk management in different fields: protection and control of the environment, installation safety, health, safety and radiation protection, transport of hazardous materials, waste management, protection of sites, installations and heritage, management of emergency situations, management of legal risks, internal audits and controls. Other topics are addressed like the presentation of the risk management department, and the role of the CEA in the relationship between research and industry

  17. Bivalent fragment of the ior-CEA1 antibody. A challenge to the positive CEA tumors radioimmunotherapy

    International Nuclear Information System (INIS)

    Ravelo, Rolando; Sanchez, Iradia; Pimentel, Gilmara; Oliva, Juan; Perez, Lincidio; Ayala, Marta; Bell, Hansell; Gavilondo, Jorge

    2006-01-01

    The directed radiotherapy of the solid tumors with fragments recombinants of radiolabelled antibodies is a topic of current investigation, so much at preclinical level as clinical. This work describes the preclinical characterization of a new fragment type diabody of the AcMo ior CEA1 that has been labelled with 131 I for their use in the diagnosis and the therapy of CEA positive tumors. The radiolabelling methodology used allows the incorporation of more than 90% of the radio iodine to the molecule without committing the capacity of recognition of its antigen significantly. The combination of the favourable properties pharmacy kinetic and high selective accumulation in the tumor, they make of the diabody anti CEA an appropriate candidate for the radioimmunodiagnosis and the radioimmunotherapy of tumors that expresses CEA (Author)

  18. CEA - Assessment of risk management 2013

    International Nuclear Information System (INIS)

    Bigot, Bernard; Bonnevie, Edwige; Maillot, Bernard

    2014-06-01

    After some introducing texts by CEA managers, this report proposes a rather detailed overview and presentation of CEA activities, objectives and obtained results in different fields: protection and control of the environment, installation safety, health, safety and radiation protection, transports of hazardous materials, waste management, protection of sites, installations and heritage, management of emergency situations, management of legal risks, internal controls and audits, activity of the risk management department, CEA activities from research to industry

  19. A difficult investment: the recruiting of scientific and technical personnel for the Commissariat a l'Energie Atomique; Un investissement difficile: le recrutement de personnel scientifique et technique pour le Commissariat a l'Energie Atomique

    Energy Technology Data Exchange (ETDEWEB)

    Bardet, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Presentation: the situation of France. 1. Part: estimation of requirements. The building of an industrial site thus created demands for huge 'investments' in scientific personnel. 1) Overall evaluation of needs; the teaching system does not produce a sufficient number of specialists. The steps taken to remedy this will not be felt before 1960. 2) Special needs of the C.E.A.: the application of 5 year plans has led to a rapid increase in staff. 2. Part: means adopted by the C.E.A. 1) Recruiting system: for various reasons (competition from private indu, number of specialities represented): - recruiting on a permanent basis; - recruiting of a comparatively large number of women scientists and technicians, etc. 2) Varied means of training: temporary employment, grants, competitions within the teaching system and in the professional training organisations. Conclusion: considerable recruiting of scientific staff by the C.E.A., but the training systems in operation represent a long-term investment for the national economy. (author)Fren. [French] Presentation: situation de la France. 1. partie: estimation des besoins. La mise en place de l'infrastructure industrielle a demande d'enormes 'investissements' en personnel scientifique. 1) Evaluation globale des besoins: l'enseignement ne forme pas un nombre suffisant de specialistes. Les mesures prises ne se feront pas sentir avant 1960. 2) Besoins particuliers du C.E.A.: l'application des plans quinquennaux a entraine un accroissement rapide des effectifs. 2. partie: moyens mis en oeuvre par le C.E.A. 1) Systeme de recrutement: pour diverses raisons (concurrence du secteur prive, multiplicite des specialites representees): - recrutement sur titres, - recrutement d'un nombre relativement eleve de femmes ingenieurs et techniciens, etc. 2) Moyens de formation varies: stages, bourses, concours apportes a l'Enseignement ainsi qu'aux organismes de formation professionnelle. Conclusion: Prelevement important de cadres scientifiques

  20. Saclay - 50 years / CEA 1945-95

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    Central in the infrastructure through which France obtains some 80% of its electric power from nuclear energy stands the French Atomic Energy Authority (Commissariat à l'Energie Atomique - CEA). This year the CEA celebrates its Golden Jubilee. Mastery of nuclear energy goes hand-in-hand with fundamental research in the fields of nuclear and sub-nuclear physics, and the founders of the CEA, like F. Joliot and F. Perrin, considered it essential to relaunch fundamental research in France after the Second World War. In particular, A. Messiah's courses on quantum mechanics made a considerable contribution to the re-establishment of a French school of atomic and sub-atomic physics. As the CEA expanded and nuclear industry grew up, the need was shown for close links between fundamental research and its applications. In addition, the CEA realized how important it was to become a part of the national and international scientific community as highly effective cooperation was developing. The CEA has drawn a wealth of scientific, cultural and intellectual benefits from its collaboration with CERN. During the same period, as fundamental particle physics research has been making spectacular progress, its requirements have grown commensurately. It is not therefore surprising that CERN needs partners capable of bringing together the domains of fundamental research and major equipment and of promoting a dialogue between research and industry. As was pointed out by Jacques Haissinski, head of the Department of Astrophysics, Particle Physics, Nuclear Physics and Associated Instruments (DAPNIA), the CEA, set up to develop major programmes for applying nuclear processes, is particularly well equipped to design, build and operate the huge instruments for exploring the infinitely small and the infinitely large. Tomorrow's nuclear industry needs and will continue to need fundamental research, with its openness and its cooperation. Particle physics needs and will continue

  1. Detectors calibration and research of luminescent materials for non baryonic dark matter detection; Calibration de detecteurs et recherche de materiaux luminescents pour la detection de la matiere noire non baryonique

    Energy Technology Data Exchange (ETDEWEB)

    Messous, M.Y.

    1995-03-01

    This work is dedicated to the characterization of luminescent materials in order to build bolometers for the simultaneous detection of heat an light in the search for WIMPs (Weakly Interacting Massive Particles) candidates for non baryonic dark matter. These double bolometers should enable the identification and measurement of recoil ions after collision between a WIMPs and material nucleus. In our search for highly luminescent materials, we have studied the emission spectra, the time response and the spectra response resulting from laser excitation or ionizing particles bombardment of some crystals such as CaF{sub 2}(Eu), CaF{sub 2}, CeF{sub 3}(Ce) and In{sub 2}Si{sub 2}O{sub 7}. These studies were conducted down to liquid Helium temperature (4 K). After showing the good performance of CaF{sub 2}(Eu) scintillator, we have measured the quenching effect resulting from {sup 19}F and Ca ions recoil in CaF{sub 2}(Eu). This was done at the 14 MeV Tandem accelerator of Bruyeres-Le-Chatel with a pulsed neutron beam, simulating the WIMPs. The data obtained allowed the exploitation of the results of the BPRS (Beijing - Rome - Paris - Saclay) experiments carried out at Gran-Sasso. This results showed a gain of up to an order of magnitude in the exclusion graph of axially coupled WIMPs compared to NaI. With the apparatus developed at IPN Lyon (Nuclear Physical Institute of Lyon), we have also measured the ionization induced by Ge ion recoils in Germanium detector, which is one of the most promising crystals for WIMPs detection in the energy range of 2.8 keV-37.8 keV. An ionization efficiency of 24% to 29% was obtained. (author). refs., figs., tabs.

  2. INIS, CEA and nuclear terminology; INIS, CEA et terminologie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Surmont, J.; Brulet, C.; Constant, A.; Guille, N.; Le Blanc, A.; Mouffron, O.; Anguise, P.; Jouve, J.J

    2007-07-01

    This poster, prepared for the fifth edition of the meetings of scientific and technical information professionals (RPIST, Nancy (France)), presents, first, the INIS information system, its content and coverage, the French participation to this system and the role of the CEA-Saclay as France's official representative for this system. Then it presents the INIS thesaurus with its different levels as a terminological tool for the indexing of documents and for searching documents inside the database. Finally, the very first electronic version of the multilingual thesaurus is introduced. Several national INIS centres, including the CEA-Saclay, have contributed to the translation of lists of new terms and of forbidden terms (synonyms). (J.S.)

  3. The CEA at the heart of great new challenges - Annual report 2015. The CEA - Financial report 2015

    International Nuclear Information System (INIS)

    2016-06-01

    The French Alternative Energies and Atomic Energy Commission (CEA) is a key player in research, development and innovation in four main areas: defence and security, nuclear energy (fission and fusion), technological research for industry, fundamental research in the physical sciences and life sciences. Drawing on its widely acknowledged expertise, the CEA actively participates in collaborative projects with a large number of academic and industrial partners. The CEA is established in nine centers spread throughout France. It works in partnership with many other research bodies, local authorities and universities. Within this context, the CEA is a stakeholder in a series of national alliances set up to coordinate French research in energy (ANCRE), life sciences and health (AVIESAN), digital science and technology (ALLISTENE), environmental sciences (AllEnvi) and human and social sciences (ATHENA). The CEA in figures (2015): 9 research centres; 15958 technicians, engineers, researchers and staff; 51 joint research units (UMR); 53 framework agreements with universities and schools; 753 priority patents filed in 2015; 27 Equipex (facilities of excellence); 33 Labex (Laboratories of excellence); 3 Idex (Initiatives of excellence); 187 start-ups since 1972 in the innovative technologies sector; 4,1 billion euros budget; 438 ongoing European projects in 2015. This document is the activity report of CEA over the year 2015 (Defence, energy, technologies, fundamental research..). It is followed by a Management and a financial report (annual Financial Statements)

  4. CEA - 2012 Annual Report, 2012 Financial Statements

    International Nuclear Information System (INIS)

    2013-01-01

    In its first part, this report proposes an overview of activities within the CEA. They concern the CEA's programs on low on carbon energies and associated fundamental researches, on defence and global security and associated fundamental researches, on information technologies and associated fundamental researches, on health technologies and associated fundamental researches, and on very large research infrastructures and associated fundamental researches. The second part addresses the scientific assessment, activities related to teaching and training, to innovation towards enterprises, and to support to valorization. It also indicates prices awarded to the CEA. The third part addresses CEA management and institutional relationships, human resources, international relationships, activities related to communication and information diffusion, and risk management. The fourth part describes the CEA organization, its governance and its various bodies. The second volume contains the financial statements for 2012

  5. Characterization of gastric adenocarcinoma cell lines established from CEA424/SV40 T antigen-transgenic mice with or without a human CEA transgene

    International Nuclear Information System (INIS)

    Nöckel, Jessica; Engel, Natasja K van den; Winter, Hauke; Hatz, Rudolf A; Zimmermann, Wolfgang; Kammerer, Robert

    2006-01-01

    Gastric carcinoma is one of the most frequent cancers worldwide. Patients with gastric cancer at an advanced disease stage have a poor prognosis, due to the limited efficacy of available therapies. Therefore, the development of new therapies, like immunotherapy for the treatment of gastric cancer is of utmost importance. Since the usability of existing preclinical models for the evaluation of immunotherapies for gastric adenocarcinomas is limited, the goal of the present study was to establish murine in vivo models which allow the stepwise improvement of immunotherapies for gastric cancer. Since no murine gastric adenocarcinoma cell lines are available we established four cell lines (424GC, mGC3, mGC5, mGC8) from spontaneously developing tumors of CEA424/SV40 T antigen (CEA424/Tag) mice and three cell lines derived from double-transgenic offsprings of CEA424/Tag mice mated with human carcinoembryonic antigen (CEA)-transgenic (CEA424/Tag-CEA) mice (mGC2 CEA , mGC4 CEA , mGC11 CEA ). CEA424/Tag is a transgenic C57BL/6 mouse strain harboring the Tag under the control of a -424/-8 bp CEA gene promoter which leads to the development of invasive adenocarcinoma in the glandular stomach. Tumor cell lines established from CEA424/Tag-CEA mice express the well defined tumor antigen CEA under the control of its natural regulatory elements. The epithelial origin of the tumor cells was proven by morphological criteria including the presence of mucin within the cells and the expression of the cell adhesion molecules EpCAM and CEACAM1. All cell lines consistently express the transgenes CEA and/or Tag and MHC class I molecules leading to their susceptibility to lysis by Tag-specific CTL in vitro. Despite the presentation of CTL-epitopes derived from the transgene products the tumor cell lines were tumorigenic when grafted into C57BL/6, CEA424/Tag or CEA424/Tag-CEA-transgenic hosts and no significant differences in tumor take and tumor growth were observed in the different hosts

  6. CEA 2009 annual report; CEA rapport annuel 2009

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    After an indication of several key figures about the activity of the CEA (Centre d'Etudes Atomiques) and its relationship with the academic as well as the industrial field, in France and worldwide, this 2009 annual report presents its various research programs in the field of defence and of global security: basic research (nuclear weapons and propulsion, struggle against proliferation and terrorism) and applied research (nuclear deterrence, national and international security). Then, it presents the programs in the field of de-carbonated energy: basic research (in material science and in life sciences) and applied research (fission energy, fusion energy, new energy technologies). A last group of research programs deals with information and health technologies and concerns life and material sciences, micro- and nano-technologies, software technologies. Interaction with other research institutions and bodies is also evoked. A brief scientific assessment is proposed. Finally, the different structures building the CEA are presented

  7. Metal extrusion using hydrostatic pressures; Le filage des metaux sous pression hydrostatique

    Energy Technology Data Exchange (ETDEWEB)

    Sauve, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The main problems connected with the deformation of metals due to extrusion are described. A method is put forward for calculating the rational rate of percentage deformation in the case of bar extrusion using a cylindrical container; reference is made to previous work on extrusion using a hydrostatic pressure with or without back-pressure. An extrusion process is described using hydrostatic pressure, without back-pressure, and using the lubricant for transmitting the thrust. This process has been used for eight years by the C.E.A. for the extrusion of a very wide range of metals, from beryllium to uranium and including steels; it leads to excellent surface textures. A very fine crystallization can be obtained on extruded products when the rate of extrusion is very low. There appears to be nothing against the use of high extrusion rates using this method. (author) [French] On expose les problemes generaux lies a la deformation des metaux par filage. On propose un calcul de la vitesse rationnelle de deformation pour cent dans le cas du filage de barres a partir d'un conteneur cylindrique, et l'on cite les travaux anterieurs sur le filage par faction d'une pression hydrostatique sans ou avec une contre-pression. On decrit un procede de filage par l'action d'une pression hydrostatique, sans contre-pression, utilisant le lubrifiant pour transmettre la poussee. Ce procede employe depuis 8 ans au C.E.A. pour filer les metaux les plus divers, depuis le beryllium jusqu'a l'uranium en passant par les aciers, permet d'obtenir d'excellents etats de surface. Une cristallisation tres fine peut etre obtenue sur les produits files lorsque le filage est tres lent. Rien ne parait s'opposer a ce que des filages rapides soient effectues avec cette methode. (auteur)

  8. CEA monitoring of palliative treatment for colorectal carcinoma.

    Science.gov (United States)

    Herrera, M A; Chu, T M; Holyoke, E D; Mittelman, A

    1977-01-01

    Palliative treatment was applied to 131 cases of unresectable or palliatively resected colorectal carcinoma being monitored with serial CEA determinations. There were 84 instances of disease progression with 67 (80%) of them showing an increase in CEA above pretreatment levels or maintaining high levels, and 17 (20%) showing a fall when compared to pretreatment values or maintaining low initial values. There was a clear-cut regression of the disease in only 9 instances. In all 9, the CEA clearly dropped or maintained low valles throughout the period of regression. No patient in regression had a rise or maintained an elevated CEA level. These changes in CEA followed closely the clinical response of our patient to the use of a particular agent, although for the Nitrosourea compounds there may be a tendency to lower the CEA regardless of the patient's tumor response to the drug. This could be due to the fact that the Nitrosoureas produce a diffuse block of cellular activity, both at the nucleous and cytoplasm; while other compounds act as alkylating agents or by inhibition of enzymes involved in the metabolism of nucleic acids (i.e., 5-FU inhibiting thymidylate synthetase). In general, longer survival was found in those patients who had initially lower levels of CEA as compared to those with high initial levels. The patients with a favorable CEA response to the treatment (falling CEA or maintained low value), even in many who did not show a clinical response had a longer survival than the group with rising or stable high levels. The main value in CEA monitoring of patients resides in its correlation with the amount of disease present and then its ability to detect progression of tumor mass which is not clinically measurable. PMID:64132

  9. Demodicidosis en pacientes con rosácea

    Directory of Open Access Journals (Sweden)

    Edhizon Trejo Mucha

    2007-01-01

    Full Text Available Objetivo: Determinar la frecuencia de demodicidosis y sus características clínicas en pacientes con rosácea. Materiales y métodos: Estudio de casos y controles en 42 pacientes con rosácea y 42 controles para describir la presencia y densidad de D. folliculorum. El estudio se realizó en el Hospital Nacional Cayetano Heredia entre marzo y setiembre del 2004, utilizándose la técnica de Tello. Resultados: Demodex folliculorum fue encontrado en los 42 pacientes con rosácea (100% y en 13 (31,0% del grupo control, (p= 0,000. La exposición a gatos, la crianza de roedores y cerdos, la seborrea y el uso de corticoides tópicos fueron mas frecuentes en los pacientes con rosácea. Conclusiones: La presencia de Demodex folliculorum fue más frecuente en los pacientes con rosácea. (Rev Med Hered 2007;18:15-21.

  10. The dismantling of CEA nuclear installations

    International Nuclear Information System (INIS)

    Piketty, Laurence

    2016-03-01

    After having indicated locations of French nuclear installations which are currently being dismantled (about 30 installations), and recalled the different categories of radioactive wastes with respect to their activity level and the associated storage options, this article gives an overview of various aspects of dismantling, more precisely in the case of installations owned and managed by the CEA. These operations comprise the dismantling itself, the recovery and packaging of wastes, old effluents and spent fuels. The organisation and responsible departments within the CEA are presented, and the author outlines some operational problematic issues met due to the age of installations (traceability of activities, regulation evolutions). The issue of financing is then discussed, and its uncertainties are outlined. The dismantling strategy within the CEA-DEN is described, with reference to legal and regulatory frameworks. The next parts of the article address the organisation and the economic impact of these decontamination and dismantling activities within the CEA-DEN, highlight how R and D and advanced technology are a support to this activities as R and D actions address all scientific and technical fields of nuclear decontamination and dismantling. An overview of three important dismantling works is proposed: Fontenay-aux-Roses, the Marcoule CEA centre (a reference centre in the field of nuclear dismantling and decontamination) and the Grenoble CEA centre (reconversion in R and D activities in the fields of technologies of information, of communication, technologies, for health, and in renewable energies). The last part addresses the participation to the Strategic Committee of the Nuclear Sector (CSFN)

  11. CEA 2005 annual report

    International Nuclear Information System (INIS)

    2006-01-01

    This document is the 2005 activity report of the French atomic energy commission (CEA). The CEA is a main actor of nuclear research, development and innovation and is involved in three main domains: energy, defense/security, and information/health technologies thanks to high quality research works. With a manpower of 15000 researchers and collaborators with internationally acknowledged competences, the CEA is a driving force of industrial innovation and develops partnerships with French and European industries. It also warrants the perenniality of nuclear dissuasion. This report presents these different aspects of the CEA activities: 1 - defense-security: simulation program, opening to the scientific community, nuclear warheads, nuclear propulsion, cleansing of Rhone valley facilities, permanent monitoring of treaties respect, fight against terrorism; 2 - energy: optimization of the industrial park, advances in long lived radioactive wastes management, future nuclear systems, cleansing and dismantling integration, European nuclear energy research, new energy technologies; 3 - information and health technologies: major challenge of micro- and nano-technologies, key role of software technologies and complex systems; 4 - big research facilities opened to the scientific and industrial communities; 5 - scientific status: scientific evaluation process, prices and honors; 6 - programs support: revisited strategic control, confirmed simplification, active employment and training policy, teaching and training, technological valorization, international relations, communication, continuous quality approach, mastery of facilities safety, security, environmental control, a key-year for information systems. A financial report is attached to the document. (J.S.)

  12. Decontamination and dismantling at the CEA

    International Nuclear Information System (INIS)

    2006-01-01

    This document presents the dismantling policy at the CEA (French Research Center on the atomic energy), the financing of the decontamination and the dismantling, the regulatory framework, the knowledge and the technology developed at the CEA, the radiation protection, the environment monitoring and the installations. (A.L.B.)

  13. The CEA's waste management strategy

    International Nuclear Information System (INIS)

    Behar, Ch.; Dall'ava, D.; Fillion, E.

    2011-01-01

    The CEA is tasked with carrying out certain research activities: within the Military Applications Division (DAM), research is focused on the nuclear deterrence and, within the Nuclear Energy Division, on developing the industrial nuclear systems of the future and optimising existing nuclear systems in partnership with EDF and AREVA. These major research and development themes entail a need for nuclear research and support facilities which must be maintained at a high level of performance and safety and, also, constantly upgraded to handle the research activities and programmes for which they are used. The CEA strategy is based on the right packaging of the radioactive liquid or solid waste into a form required for its transport, storage or disposal. The Caraibes software allows an efficient traceability of the waste packages. Most of the radioactive effluent processing stations of CEA are being upgraded

  14. The CEA's waste management strategy; La strategie de gestion des dechets du CEA

    Energy Technology Data Exchange (ETDEWEB)

    Behar, Ch. [CEA Saclay, Dir. de l' Energie Nucleaire, 91 - Gif-sur-Yvette (France); Dall' ava, D. [CEA Saclay, Dir. de l' assainissement et du demantelement nucleaire, 91 - Gif-sur-Yvette (France); Fillion, E. [CEA Fontenay-aux-Roses, Direction de la protection et de la surete nucleaire, 92 (France)

    2011-02-15

    The CEA is tasked with carrying out certain research activities: within the Military Applications Division (DAM), research is focused on the nuclear deterrence and, within the Nuclear Energy Division, on developing the industrial nuclear systems of the future and optimising existing nuclear systems in partnership with EDF and AREVA. These major research and development themes entail a need for nuclear research and support facilities which must be maintained at a high level of performance and safety and, also, constantly upgraded to handle the research activities and programmes for which they are used. The CEA strategy is based on the right packaging of the radioactive liquid or solid waste into a form required for its transport, storage or disposal. The Caraibes software allows an efficient traceability of the waste packages. Most of the radioactive effluent processing stations of CEA are being upgraded

  15. The use and evolution of the CEA research reactors; Utilisation et evolution des reacteurs de recherche du C.E.A

    Energy Technology Data Exchange (ETDEWEB)

    Rossillon, F; Chauvez, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    reacteurs en montrant ce qu'a ete jusqu'a present leur utilisation, et comment certaines modifications ont permis de les adapter a l'evolution des programmes. Ils precisent egalement les raisons qui ont conduit a l'elaboration du projet de la nouvelle pile OSIRIS, La pile ZOE, la plus ancienne du CEA, est en service au Centre de Fontenay-aux-Roses depuis 1948. Elle est principalement utilisee pour les mesures de section efficace d'absorption du graphite, et pour diverses irradiations de courte duree ne necessitant que des flux peu eleves. La Pile EL2, en service depuis 1952, a permis les premieres etudes liees au refroidissement par gaz. Elle a ete tres utilisee pour la production des radioisotopes et pour de nombreuses experiences de physique, de metallurgie et de physico-chimie - le vieillissement de certaines parties du reacteur a conduit a decider l'arret prochain de cette installation. La Pile EL. 3 a ete tres utilisee pour les experiences de physique et pour l'etude des combustibles. L'adoption d'une nouvelle structure pour le coeur (solution 'Cristal de neige') va permettre d'accroitre considerablement les possibilites de la pile pour les irradiations en neutrons rapides. La pile TRITON-I, piscine de 2 MW, est surtout utilisee pour les irradiations en neutrons rapides et en gamma. Certaines modifications, actuellement en cours, permettront d'accroitre la puissance du reacteur jusqu'a 4 ou 5 MW. Dans un compartiment voisin de TRITON-I est implantee la Pile TRITON-II, de meme structure generale, mais dont la puissance maximum est de 100 kW. TRITON-II est utilisee exclusivement pour les etudes de protections. MELUSINE, pile piscine de 2 MW est en fonctionnement au Centre d'Etudes Nucleaires de Grenoble depuis 1959. Elle a permis l'execution d'un programme important concernant surtout la physique du solide, l'etude fondamentale de combustibles refractaires et de graphites speciaux, et l'etude du comportement des liquides organiques sous radiations. Les installations de

  16. 2004 annual report. Defense, safety, energy, information, health. CEA in the center of big European challenges; Rapport annuel 2004. Defense, securite, energie, information, sante. Le CEA au coeur des grands defis europeens

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    This document is the 2004 annual report of the French atomic energy commission (CEA). It presents the R and D activities of the CEA in three main domains: 1 - defense and safety, maintaining perenniality of nuclear dissuasion and nuclear safety: supplying nuclear weapons to armies, maintaining dissuasion capability with the simulation program, sharing R and D means with the scientific community and the industrial world, designing and maintaining naval nuclear propulsion reactors, cleansing Marcoule and Pierrelatte facilities, monitoring treaties and fighting against proliferation and terrorism; 2 - energy, developing more competitive and cleaner energy sources: nuclear waste management, optimization of industrial nuclear activities, future nuclear systems and new energy technologies, basic research on energy, radiobiology and toxicology; 3 - information and health, valorizing industry thanks to technological research and supplying new tools for health and medical research: micro- and nano-technologies, software technologies, basic research for industrial innovation, nuclear technologies for health and bio-technologies. (J.S.)

  17. Fifty years of particle physics at the CEA

    International Nuclear Information System (INIS)

    Turlay, R.

    1997-01-01

    A historical review of researches at the CEA (and more particularly at Saclay) in particle physics, is presented. Contributions in themes such as polarized targets, bubble chambers, classic and superconductive magnets, etc. resulted in cooperation to the design of various machines such as Van de Graaff accelerator, cyclotron, Saturne, etc. Collaborations between CEA and CERN had led to numerous experiments in high energy physics, such as electronic experiments with the SPS accelerator. CEA was also involved in the intermediate boson discovery on the SppS collision apparatus, and is participating in two CERN's programs, neutrino physics (NOMAD) and CP violation (NA48). CEA is also collaborating with Russian, German and American laboratories in these domains

  18. Scientific evaluation at the CEA

    International Nuclear Information System (INIS)

    1999-01-01

    This report presents a statement of the scientific and technical activity of the French atomic energy commission (CEA) for the year 1998. This evaluation is made by external and independent experts and requires some specific dispositions for the nuclear protection and safety institute (IPSN) and for the direction of military applications (DAM). The report is divided into 5 parts dealing successively with: part 1 - the CEA, a public research organization (civil nuclear research, technology research and transfers, defence activities); the scientific and technical evaluation at the CEA (general framework, evaluation of the IPSN and DAM); part 2 - the scientific and technical councils (directions of fuel cycle, of nuclear reactors, and of advanced technologies); part 3 - the scientific councils (directions of matter and of life sciences); the nuclear protection and safety institute; the direction of military applications; part 4 - the corresponding members of the evaluation; part 5 - the list of scientific and technical councils and members. (J.S.)

  19. CEA - 2011 annual report, 2011 financial statement

    International Nuclear Information System (INIS)

    2012-06-01

    The first report, available both in French and English, presents the different current programs: low carbon energies and associated fundamental researches, global defence and safety and associated researches, information technologies and associated researches, technologies for health and associated fundamental researches, very large research infrastructures and associated fundamental researches. It then addresses the CEA openness: assessment, teaching and training, research valorisation, awards, and the support to various programs: steering activity by the CEA, human resources, international relationships, communication, risk management, information systems. The last part describes the CEA organisation. The second report presents the different financial and accounting data and tables

  20. Observation on CEA and IL-6 contents in gastric juice

    International Nuclear Information System (INIS)

    Jiang Zhonglin

    2003-01-01

    Objective: To study the changes of CEA and IL-6 contents in blood and gastric juice in patients with gastric cancer and gastritis. Methods: CEA and IL-6 contents in blood and gastric juice were measured with RIA in 60 patients and 30 controls. Results: Gastric juice CEA and IL-6 contents in patients with gastric carcinoma were significantly higher than those in the controls (p < 0.001), however, CEA and IL-6 contents in patients with gastritis and controls were not much different. Conclusion: Gastric juice CEA and IL-6 assay is of diagnostic significance in patients with gastric malignant tumor

  1. CEA Annual progress report 1986

    International Nuclear Information System (INIS)

    1987-01-01

    This annual report presents the general organization of the CEA, the international relations and politics in nuclear field, the activities (military application, nuclear applied research, ANDRA (National Agency for Radioactive Waste Management), nuclear safety and protection, fundamental research, applied research other than nuclear), the industrial group; among topics about men and means, the budget execution of the public establishment of research. In annex, the nuclear power plants around the world and the principal legislative texts related to CEA or atomic energy published in 1986 [fr

  2. Big reorganisation at the CEA; [structural reorganisation and reform of management methods within the CEA; CEA document on civil nuclear energy policy research

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Following the recommendations of a report prepared by the Director General, CEA is to be reorganised to clarify the division of responsibility within the CEA and to increase its adaptability and openness to the outside world. The management structures have been simplified and two large institutes of the Commissariat, the Institute of Industrial Research and Development and the Institute of Fundamental Research have been disbanded and their activities reallocated to six smaller operational directorates. Seven functional directorates have been created to cover communications, finance, defence issues, manpower, international relations, planning and secretariat. An outline of the new structure is given and explained. (UK)

  3. Presentation of CEA

    International Nuclear Information System (INIS)

    Graf, J.J.

    1976-01-01

    The organization of the CEA, its missions and means are presented. Its activities in the field of light water reactors, fast neutron reactors and PWR reactors of small and medium power for electricity and/or heat generation are emphasized [fr

  4. Carcinoembryonic antigen (CEA) as tumor marker in lung cancer.

    Science.gov (United States)

    Grunnet, M; Sorensen, J B

    2012-05-01

    The use of CEA as a prognostic and predictive marker in patients with lung cancer is widely debated. The aim of this review was to evaluate the results from studies made on this subject. Using the search words "CEA", "tumor markers in lung cancer", "prognostic significance", "diagnostic significance" and "predictive significance", a search was carried out on PubMed. Exclusion criteria was articles never published in English, articles before 1981 and articles evaluating tumor markers in lung cancer not involving CEA. Initially 217 articles were found, and 34 were left after selecting those relevant for the present study. Four of these included both Non-Small Cell Lung Cancer (NSCLC) and Small Cell Lung Cancer (SCLC) patients, and 31 dealt solely with NSCLC patients. Regarding SCLC no studies showed that serum level of CEA was a prognostic marker for overall survival (OS). The use of CEA serum level as a prognostic marker in NSCLC was investigated in 23 studies and the use of CEA plasma level in two. In 18 (17 serum, 1 plasma) of these studies CEA was found to be a useful prognostic marker for either OS, recurrence after surgery or/and progression free survival (PFS) in NSCLC patients. Interestingly, an overweight of low stage (stage I-II) disease and adenocarcinoma (AC) patients were observed in this group. The remaining 7 studies (6 serum, 1 plasma) contained an overweight of patients with squamous carcinoma (SQ). One study found evidence for that a tumor marker index (TMI), based on preoperative CEA and CYFRA21-1 serum levels, is useful as a prognostic marker for OS in NSCLC. Six studies evaluated the use of CEA as a predictive marker for risk of recurrence and risk of death in NSCLC patients. Four of these studies found, that CEA was useful as a predictive marker for risk of recurrence and risk of death measured over time. No studies found CEA levels useful as a diagnostic marker for lung cancer. With regard to NSCLC the level of CEA measured in tumor tissue in

  5. Fusion technology. Annual report of the. Association Cea/EURATOM; Technologie de fusion.Rapport annuel de l`association CEA/Euratom

    Energy Technology Data Exchange (ETDEWEB)

    Magaud, P; Le Vagueres, F

    1997-12-31

    In 1996, the French EURATOM-CEA Association made significant contributions to the European technology programme. This work is compiled in this report as follows: the ITER CEA activities and related developments are described in the first section; blankets and material developments for DEMO, long term safety studies are summarised in the second part; the Underlying Technology activities are compiled in the third part of this report. In each section, the tasks are sorted out to respect the European presentation. For an easy reading, appendix 4 gives the list of tasks in alphabetical order with a page reference list. The CEA is in charge of the French Technology programme. Three specific organizational directions of the CEA, located on four sites (see appendix 5) are involves in this programme: Advanced Technologies Direction (DTA), for Material task; Nuclear Reactors Direction (DRN), for Blanket design, Neutronic problems, Safety tasks; Physical Sciences Direction (DSM) uses the competence of the Tore Supra team in the Magnet design and plasma Facing Component field. The CEA programme is completed by collaborations with Technicatome, COMEX-Nucleaire and Ecole Polytechnique. The breakdown of the programme by Directions is presented in figure 1. The allocation of tasks is given in appendix 2 and in appendix 3, the related publications. (author).

  6. Fusion technology. Annual report of the. Association Cea/EURATOM; Technologie de fusion.Rapport annuel de l`association CEA/Euratom

    Energy Technology Data Exchange (ETDEWEB)

    Magaud, P.; Le Vagueres, F.

    1996-12-31

    In 1996, the French EURATOM-CEA Association made significant contributions to the European technology programme. This work is compiled in this report as follows: the ITER CEA activities and related developments are described in the first section; blankets and material developments for DEMO, long term safety studies are summarised in the second part; the Underlying Technology activities are compiled in the third part of this report. In each section, the tasks are sorted out to respect the European presentation. For an easy reading, appendix 4 gives the list of tasks in alphabetical order with a page reference list. The CEA is in charge of the French Technology programme. Three specific organizational directions of the CEA, located on four sites (see appendix 5) are involves in this programme: Advanced Technologies Direction (DTA), for Material task; Nuclear Reactors Direction (DRN), for Blanket design, Neutronic problems, Safety tasks; Physical Sciences Direction (DSM) uses the competence of the Tore Supra team in the Magnet design and plasma Facing Component field. The CEA programme is completed by collaborations with Technicatome, COMEX-Nucleaire and Ecole Polytechnique. The breakdown of the programme by Directions is presented in figure 1. The allocation of tasks is given in appendix 2 and in appendix 3, the related publications. (author).

  7. Carcinoembryonic antigen (CEA) as tumor marker in lung cancer

    DEFF Research Database (Denmark)

    Knudsen, Mie Grunnet; Sorensen, J B

    2012-01-01

    The use of CEA as a prognostic and predictive marker in patients with lung cancer is widely debated. The aim of this review was to evaluate the results from studies made on this subject. Using the search words "CEA", "tumor markers in lung cancer", "prognostic significance", "diagnostic...... significance" and "predictive significance", a search was carried out on PubMed. Exclusion criteria was articles never published in English, articles before 1981 and articles evaluating tumor markers in lung cancer not involving CEA. Initially 217 articles were found, and 34 were left after selecting those...... relevant for the present study. Four of these included both Non-Small Cell Lung Cancer (NSCLC) and Small Cell Lung Cancer (SCLC) patients, and 31 dealt solely with NSCLC patients. Regarding SCLC no studies showed that serum level of CEA was a prognostic marker for overall survival (OS). The use of CEA...

  8. The ''Le Bouchet'' affair - lessons to be learned

    International Nuclear Information System (INIS)

    Lallement, R.

    1993-01-01

    From 1990 to 1992 the French Atomic Energy Commission (CEA) experienced a tumultuous conflict involving many different parties: environmentalist associations, local elected officials, regional or national media, government entities, and national elected officials. The object of this conflict was an area used for the storage of radium-containing waste generated by the Le Bouchet plant about 50 kilometers south of Paris. In the 1950s, the Le Bouchet plant processed uranium and thorium ore as well as uranium concentrates to produce the uranium required for the first fuels used in the reactors of the French nuclear energy program. It was also at Le Bouchet that the first milligrams of plutonium from the fuel of France's first nuclear reactor, Zoe, were extracted. The conflict highlighted broad issues as well as specific aspects of radioactive waste management. Specifically, it raised such concerns as the legal problem of defining low-level radioactive waste, public questions about the harmfulness of radioactivity, the demand to know where all low level radioactive waste storage facilities are located with a concomitant refusal to accept them anywhere, and the new requirements for communication with the affected populations and all their representatives. (author)

  9. The CEA-Industrie Group of Companies

    International Nuclear Information System (INIS)

    1988-01-01

    The 1988 financial and technological status of the CEA-Industry Group of Companies is summarized. The activities, technological innovations, and areas of development perspectives of the CEA-Industry Group of Companies, chiefly concentrated in fields relating to nuclear energy, are described. The principal business sectors of the group involve nuclear fuel cycle, nuclear plants and maintenance, computer applications and life science. Some activities of the group are extended to management, construction and financial fields

  10. The evaluation of the nuclear facilities safety at the CEA from 1999 to 2001; Le bilan de la surete des installations nucleaires du CEA du 1999 a 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-11-01

    The aim of this document is the presentation of an evaluation of the problems and the safety methods in the concerned period. The first chapter presents the nuclear safety in the CEA. The second chapter is devoted to the organization and the quality for the safety: liabilities, audits, relations with the safety authorities and with the public. The chapters three and four deal respectively with the methodological and technical abilities supporting the exploitation teams and with the nuclear safety projects. The last chapter presents the experiments and events from 1999 to 2001. (A.L.B.)

  11. Nuclear toxicology at CEA

    International Nuclear Information System (INIS)

    Giustranti, C.

    2001-01-01

    CEA (French commission of atomic energy) has launched a new program dedicated to the study of the transfer of heavy metals and some radionuclides from environment to living beings. The substances that will be studied, are those that are involved in research, medical activities, and in nuclear industry. It means iodine, technetium, trans-uranides (uranium and plutonium), fission products (iodine, cesium), carbon, cobalt, boron and beryllium. This program is composed of 2 axis: the first one concerns the bio-geo-chemical cycles that are involved in transfer and the second axis deals with the detoxication processes that appear in animal and man cells. This program will rely on the strong competencies of CEA in chemistry, radiochemistry, biology, physiology and toxicology. (A.C.)

  12. CEA - Annual report 2006

    International Nuclear Information System (INIS)

    2006-01-01

    The CEA, a prominent player in research development and innovation, is active in 3 main areas: energy, health care and information technology and defense and security. This annual report presents the CEA activity for the year 2006 in these three main areas: Science and technology working for nuclear deterrence and global security (the simulation programs, the nuclear warheads, the nuclear propulsion, the decommissioning, the fighting against nuclear proliferation and monitoring international treaties, the global security); health and information technology (micro and nano technologies and systems); energy from nuclear fission and fusion and other technologies that do not emit greenhouse gases (progress for the nuclear industry, sustainable management of radioactive materials and waste, nuclear systems of the future, new energy technologies). (A.L.B.)

  13. How the CEA sorts out its certifications

    International Nuclear Information System (INIS)

    Lembezat, C.

    2011-01-01

    In order to better manage its numerous certifications, the French CEA decided to implement an integrated management system. It aims at simplifying these certifications, at sharing best practices, and at obtaining a better efficiency. For this project, i.e. the management of quality, safety and environment, the CEA asked for the support of experts in integrated complex system management

  14. Life sciences at CEA

    International Nuclear Information System (INIS)

    2000-01-01

    This paper presents briefly the organization of the - Direction des Sciences du Vivant - of french atomic energy commission (Commissariat a l'Energie Atomique (CEA)) and their main axes of research (F.M)

  15. CEA A BIOCHEMICAL MARKER FOR DIAGNOSIS AND PROGNOSIS OF GASTROINTESTINAL CANCER

    Directory of Open Access Journals (Sweden)

    Prathibha

    2016-02-01

    Full Text Available Serum tumor markers (TM are widely used for diagnosis and monitoring of treatment of cancer. Carcinoembryonic Antigen (CEA is one of the most widely investigated tumor markers in gastrointestinal (GI cancers. Estimation of circulating tumor markers is a non- invasive quantitative method. Serum levels of CEA were studied for diagnosis and prognosis of gastrointestinal malignancies. 140 subjects were undertaken out of which 35 normal and remaining 105 were GI cancer patients. Serum levels of CEA were analyzed by Enzyme Linked Immunosorbent Assay (ELISA. Result of serum CEA levels of the GI cancer patients and normal subjects were analyzed statistically. It was observed that there was significant increase in (P <0.01 in CEA levels of oesophagus, stomach and colon cancer patients as compared to normal subjects. The levels of CEA decreased significantly after the surgery but the decrease in levels of CEA was not up to the levels as normal control subjects.

  16. Scientific evaluation at the French Atomic Energy Commission (CEA). 2005-2006 annual report; L'evaluation scientifique au CEA. Rapport annuel 2005-2006

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    This report aims at presenting the scientific evaluation activities carried out at the CEA during the years 2005-2006. The evaluation system is described in detail. It comprises two aspects: the evaluation of the scientific policy implemented by the scientific Council and by the visiting committee of the CEA, and the evaluation of the laboratories, performed by a pool of 36 scientific councils. The evaluation by external and independent parties is the key point of this system. This document makes a status of the evaluations performed in 2005 and 2006. It presents a synthesis of the conclusions of the evaluation authorities. The actions implemented by the CEA to take into consideration the recommendations are also reported with the improvements noticed. The two topics examined by the scientific Committee and by the visiting committee were dealing with the energy domain, which is a strategic issue for the CEA. The examination of the researches on future nuclear reactors and on new energy technologies have shown the major role played by the CEA in the recent advances in these domains. About 95% of the laboratories activity was examined during the 2002-2005 period. The richness of the remarks and recommendations made by the scientific councils should allow the CEA to improve the quality and relevance of its research works. The start-up of the 2006-2009 evaluation cycle has been the occasion to modify the evaluation of some research domains in order to take into account the evolution of programs. The evaluation system of the CEA is highly consistent with the AERES principles. Its implementation, adapted to each type of activity (fundamental research, applied research, technological developments) allows the CEA to follow up a permanent improvement approach. (J.S.)

  17. Report transparency and nuclear safety 2007 CEA Grenoble; Rapport transparence et securite nucleaire 2007 CEA Grenoble

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This report presents the activities of the CEA Center of Grenoble for the year 2007. Since 2002 the Passage project aims to realize the decontamination and the dismantling of old nuclear installations of the CEA Grenoble. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially the year 2007 saw two main steps of the Passage project: the decommissioning of the Siloette reactor, a public consultation about the Lama laboratory dismantling. (A.L.B.)

  18. Influencing factors on the serum carcinoembryonic antigen (CEA) in benign liver diseases

    International Nuclear Information System (INIS)

    Pompecki, R.; Mehl, H.; Fehr, R.; Braun, H. von

    1982-01-01

    Carcinoembryonic antigen (CEA) was determined in the sera of 452 patients with benign liver diseases by radioimmunoassay (CEA-RIA Kit, Abbott). The CEA-level exceeded 2.5 ng/ml in 39 percent and 5.0 ng/ml in 9 percent of the cases. Independent influences of age, nicotin, and alcohol consumption and connective tissue proliferation of the liver on the CEA level were demonstrated and quantified by two- and higher-dimensional contingency table analysis. Toxic liver diseases were combined with elevated serum CEA values more often than inflammatory diseases. This aspect could not be investigated independently since there were only a few cases of toxic liver diseases without alcohol consumption. Sex and relative body weight do not seem to affect the CEA level. Additional diseases of the gastrointestinal tract or the cardiovascular system did not influence the serum CEA level in liver diseases. Therefore, in patients with benign liver diseases, an elevated serum CEA level indicates increased proliferation of the connective tissue. Age, nicotin, and alcohol consumption have to be considered independently in the clinical judgement of elevated serum CEA levels, irrespective of the underlying disease. (orig.) [de

  19. CEA financial report 2007

    International Nuclear Information System (INIS)

    2007-01-01

    This document provides financial data on the CEA for the year 2007. The management report (budget, resources, expenditures) and the accounting are detailed. The main management events of the year 2007 are presented. (A.L.B.)

  20. Serum carcinoembryonic antigen (CEA) in chronic renal failure

    International Nuclear Information System (INIS)

    Pyo, H.J.; Kim, S.G.; Shin, Y.T.; Kwon, I.S.; Chung, S.I.; Lee, J.S.; Koh, C.S.

    1980-01-01

    The serum CEA levels were measured by radioimmunoassay technique in 15 patients with chronic renal failure, who were not treated with hemodialysis, in 39 patients under hemodialysis and in 23 patients who received renal transplantation. The results were compared with those in 65 normal adults and the following results were obtained. 1) Serum CEA concentrations in 65 normal adults were in the range of 1.0 to 4.3 ng/ml with a mean value of 1.6+-0.66 ng/ml. 2) Serum CEA concentrations in 15 chronic renal failure patients who were not treated with hemodialysis, were in the range of 0.3 to 8.3 ng/ml with a mean value of 3.6+-2.10 ng/ml which was significantly higher than those of normal controls (P 0.05). 4) In 23 patients who received renal transplantation, serum CEA levels were significantly higher than normal controls (P<0.001), but not significantly different from those of chronic renal failure patients. (author)

  1. Monte Carlo Codes Invited Session

    International Nuclear Information System (INIS)

    Trama, J.C.; Malvagi, F.; Brown, F.

    2013-01-01

    This document lists 22 Monte Carlo codes used in radiation transport applications throughout the world. For each code the names of the organization and country and/or place are given. We have the following computer codes. 1) ARCHER, USA, RPI; 2) COG11, USA, LLNL; 3) DIANE, France, CEA/DAM Bruyeres; 4) FLUKA, Italy and CERN, INFN and CERN; 5) GEANT4, International GEANT4 collaboration; 6) KENO and MONACO (SCALE), USA, ORNL; 7) MC21, USA, KAPL and Bettis; 8) MCATK, USA, LANL; 9) MCCARD, South Korea, Seoul National University; 10) MCNP6, USA, LANL; 11) MCU, Russia, Kurchatov Institute; 12) MONK and MCBEND, United Kingdom, AMEC; 13) MORET5, France, IRSN Fontenay-aux-Roses; 14) MVP2, Japan, JAEA; 15) OPENMC, USA, MIT; 16) PENELOPE, Spain, Barcelona University; 17) PHITS, Japan, JAEA; 18) PRIZMA, Russia, VNIITF; 19) RMC, China, Tsinghua University; 20) SERPENT, Finland, VTT; 21) SUPERMONTECARLO, China, CAS INEST FDS Team Hefei; and 22) TRIPOLI-4, France, CEA Saclay

  2. Hearing of Mr Bernard Bigot, general administrator of the Atomic Energy Commissariat (CEA), on the CEA missions and on Cadarache events

    International Nuclear Information System (INIS)

    2009-01-01

    In this hearing by the Sustainable Development and Land Planning Commission of the French National Assembly, the role and missions of the CEA are presented while evoking its relationship with the State. The CEA representative evokes the various research activities in three main domains: energy, defence, information and health technologies. Then, he discusses the problem of the ageing and dismantling of some installations, notably in the plutonium Technology workshop (ATPu) in Cadarache. He describes this installation, the processes in which it is involved, the safety and security requirements, and comments the problem which occurred in this workshop (plutonium retention in glove boxes). Then he answers several questions asked by the Commission members about the way the CEA handled this incident, and about its severity. Other aspects are addressed like the importance of the nuclear industry and the role the CEA could have in the management of renewable energies at the national level

  3. CEA and mining industry

    International Nuclear Information System (INIS)

    Anon.

    2003-01-01

    The French atomic energy commission (CEA) is involved in the mining industry in several ways: - in the front-end of the nuclear industry through its daughter companies and participations in the exploration and exploitation of uranium ores, but also of gold and alloy metals with a 26% participation in Eramet company, the world leader of manganese and nickel. This activity is the main occupation of Cogema daughter company, via the Areva holding; - in the back-end of the nuclear fuel cycle with the delicate problem of the management of radioactive wastes; - in parallel with the nuclear industry through an important activity in semiconductor materials (FCI and SMTElectronics); - and finally through various research works on several mineral compounds. This article focusses on the fuel cycle aspects of the CEA activities and concludes with the research works carried out today on thermonuclear fusion. (J.S.)

  4. Anti-CEA loaded maghemite nanoparticles as a theragnostic device for colorectal cancer

    Directory of Open Access Journals (Sweden)

    Campos da Paz M

    2012-10-01

    Full Text Available Mariana Campos da Paz,1 Maria de Fátima M Almeida Santos,1 Camila MB Santos,2 Sebastião W da Silva,2 Lincoln Bernardo de Souza,3 Emília CD Lima,3 Renata C Silva,1 Carolina M Lucci,1 Paulo César Morais,2 Ricardo B Azevedo,1 Zulmira GM Lacava11Instituto de Ciências Biológicas; 2Instituto de Física, Universidade de Brasília, Brasília, DF, Brazil; 3Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, BrazilAbstract: Nanosized maghemite particles were synthesized, precoated (with dimercaptosuccinic acid and surface-functionalized with anticarcinoembryonic antigen (anti-CEA and successfully used to target cell lines expressing the CEA, characteristic of colorectal cancer (CRC cells. The as-developed nanosized material device, consisting of surface decorated maghemite nanoparticles suspended as a biocompatible magnetic fluid (MF sample, labeled MF-anti-CEA, was characterized and tested against two cell lines: a high-CEA expressing cell line (LS174T and a low-CEA expressing cell line (HCT116. Whereas X-ray diffraction was used to assess the average core size of the as-synthesized maghemite particles (average 8.3 nm in diameter, dynamic light scattering and electrophoretic mobility measurements were used to obtain the average hydrodynamic diameter (550 nm and the zeta-potential (−38 mV of the as-prepared and maghemite-based nanosized device, respectively. Additionally, surface-enhanced Raman spectroscopy (SERS was used to track the surface decoration of the nanosized maghemite particles from the very first precoating up to the attachment of the anti-CEA moiety. The Raman peak at 1655 cm−1, absent in the free anti-CEA spectrum, is the signature of the anti-CEA binding onto the precoated magnetic nanoparticles. Whereas MTT assay was used to confirm the low cell toxicity of the MF-anti-CEA device, ELISA and Prussian blue iron staining tests performed with both cell lines (LS174T and HCT116 confirm that the as-prepared MF-anti-CEA

  5. Comparison of CA15-3 and CEA in breast cancer

    International Nuclear Information System (INIS)

    Rajkovaca, Z.; Mijatovic, J.; Matavulj, A.; Kovacevic, P.; Ponorac, N.

    2002-01-01

    Aim: Tumor markers are potentially powerful means for obtaining information about cancers whilst causing minimal morbidity, inconvenience and cost. CA 15-3 and CEA are considered useful tumor markers in monitoring breast cancer patients. The aim of this study was to evaluate which of these two markers are in better correlate with the disease in patients surgically treated for breast cancer. Material and Methods: We retrospectively reviewed values of CA15-3 and CEA in 342 patients (median age 52.18 years, range 27-78 years) with surgically treated and pathologically proven breast cancer. CA15-3 and CEA was measured by radioimmunoassay. CA15-3 levels above 30 U/ml and CEA levels above 5 ng/ml were considered as positive values. Results: Out of 342 patients, 86 had elevated CA15-3 levels (sensitivity: 25.1%) and 68 of 342 patients had positive CEA levels (sensitivity 19.9%). Two hundred thirty seven (237) of the patients suffering from breast cancer (69.3%) did not have metastatic disease. In this group CA15-3 sensitivity was 94.5%, while CEA sensitivity was 87.3%. One hundred and five (105) patients (30.7%) had metastatic disease. In this group, CA15-3 sensitivity was 69.5% and CEA sensitivity was 36.2% (P < 0.05). With regard to the correlation of the two tumor markers with clinical course patients had significantly higher levels of CA15-3 than of CEA in metastatic breast cancer. Conclusion: This result suggests CA15-3 to be the more sensitive and more specific of the two tumor markers for metastatic breast cancer detection and monitoring

  6. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26

    International Nuclear Information System (INIS)

    Watanabe, N.; Gunma Univ. School of Medicine; Oriuchi, N.; Inoue, T.; Sugiyama, S.; Kuroki, M.; Matsuoka, Y.; Tanada, S.; Murata, H.; Sasaki, Y.

    1999-01-01

    Aim: The purpose of this study was to assess the potential for radioimmunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. Methods: The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. Results: The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 ± 0.95% vs. 11.9 ± 0.55% at 100 ng/mL of soluble CEA, 83.5 ± 2.84% vs. 54.0 ± 2.54% at 10 7 of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 ± 3.50% ID/g vs. 14.4 ± 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 ± 2.10% ID/g vs. 8.01 ± 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 ± 1.70% ID/g vs. 8.10 ± 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). Conclusion: 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer. (orig.) [de

  7. The CEA in mutation redefines its strategy

    International Nuclear Information System (INIS)

    Anon.

    2005-01-01

    The French atomic energy commission has redefined its medium- and long-term plan which fixes its strategy for the ten coming years. A. Bugat, general director of the CEA briefly presents the new missions of the CEA: budget and investments, cooperation with universities, place of fundamental research, activities in fuel cells and photovoltaic energy, cooperation with EdF, Areva and Cogema in civil nuclear research. Short paper. (J.S.)

  8. Carcinoembryonic antigen (CEA) dynamics in stomach cancer patients receiving cryotherapy

    International Nuclear Information System (INIS)

    Myasoedov, D.V.; Krupka, I.N.; V'yunitskaya, L.V.

    1986-01-01

    Radioimmunologic assays of blood serum carcinoembryonic antigen (CEA) level were conducted at major stages of treatment of gastric cancer by subtotal stomach resection and gastrectomy with preliminary cryotreatment and thawing of tumor. A short-term rise in CEA level occurred in 53.9 % of cases 3-4 days after combined therapy. A decrease in CEA concentration at discharge from hospital as compared with preoperative level and that registered 3-4 days after operation was observed in 50 and 75 % of cases of combined therapy, respectively, and 47.5 and 37.5 % of controls (surgery without cryotreatment). There was nocorrelation between cryotreatment and changes in CEA level in gastric ulcer patients

  9. INIS, CEA and nuclear terminology

    International Nuclear Information System (INIS)

    Surmont, J.; Brulet, C.; Constant, A.; Guille, N.; Le Blanc, A.; Mouffron, O.; Anguise, P.; Jouve, J.J.

    2007-01-01

    This poster, prepared for the fifth edition of the meetings of scientific and technical information professionals (RPIST, Nancy (France)), presents, first, the INIS information system, its content and coverage, the French participation to this system and the role of the CEA-Saclay as France's official representative for this system. Then it presents the INIS thesaurus with its different levels as a terminological tool for the indexing of documents and for searching documents inside the database. Finally, the very first electronic version of the multilingual thesaurus is introduced. Several national INIS centres, including the CEA-Saclay, have contributed to the translation of lists of new terms and of forbidden terms (synonyms). (J.S.)

  10. A study of factors influencing plasma CEA levels in an unselected population.

    Science.gov (United States)

    Herbeth, B; Bagrel, A

    1980-01-01

    Plasma carcinoembryonic antigen (CEA) levels were measured by an immunoenzymic method (Abbott) in 1020 subjects attending the Preventive Medicine Centre (Vandoeuvre-les-Nancy). The results are assessed in relation to: sex, age, body build, fasting/normal food intake, smoking, alcohol intake, drug medication, and working environment. The mean plasma CEA level is 1.53 ng/ml. 87% of the total group has levels less than 2.5 ng/ml, 11.2% levels between 2.5 ng/ml and 5 ng/ml and 1.8% levels above 5 ng/ml. One person had a level above 10 ng/ml. Men had significantly higher CEA levels than women. Smoking was more frequent in both men and women with CEA levels above 2.5 ng/ml. Only in men were age, alcohol consumption and a poor work environment significantly associated with CEA levels higher than 2.5 ng/ml. Obesity in women was related to higher CEA levels. Food intake and drug medication were without influence on the CEA level.

  11. Introduction to the CEA family: structure, function and secretion.

    Science.gov (United States)

    Von Kleist, S

    1992-01-01

    Due to the phenomenal progress in the field of tumor immunology that took place during the last twenty years, we dispose today of highly specific and sensitive techniques and reagents like monoclonal antibodies (MAbs). In this context the discovery in human carcinomas of tumor-associated antigens, such as CEA, was of primary importance, especially since the latter was found to have clinical relevance as a tumor marker. Based on animal models, a new in vivo technology for the detection of tumors and metastases was developed in recent years, that uses anti-CEA MAbs, or fragments of them, coupled to radio-isotopes. This technique, called radio-immunodetection (RAID), also paved the way for immunotherapeutic procedures, where again CEA served as the target-antigen. This new technique holds great promise, provided the epitope-specificity of the MAbs is well-controlled: it has been shown that CEA belongs to a large gene-family of at least 22 members, which can be subdivided into two subgroups (i.e., the CEA- and the PSG-subgroup) and which in turn belongs to the immunoglobulin-supergene family. Great structural similarities render the distinction of the various cross-reactive molecules by immunological means rather difficult.

  12. Morfometría de semillas en la cactácea amenazada de extinción Astrophytum myriostigma Lemaire

    Directory of Open Access Journals (Sweden)

    Jaime Sánchez-Salas

    2015-07-01

    Full Text Available Se presenta un estudio morfométrico y microestructural en semillas de una población de la cactácea amenazadaAstrophytum myriostigmaLem., removida en su tota- lidad en el sitio por saqueo. Se incluyen resultados que separan tamaños de semillas y embriones (grandes y pequeños así como promedios para ambos. Se realizó una descripción de características en la semilla obtenidas mediante estereoscopía. Se incluye una descripción detallada de la forma y color, así como microestructural del funículo, capa funicular y otras estructuras que le acompañan.

  13. The organisation of criticality hazard prevention at the CEA

    International Nuclear Information System (INIS)

    Mijuin, Dominique; Carros, Helene; Sevestre, Bernard

    2003-01-01

    This paper deals with the organisation of criticality hazard prevention at the French Atomic Energy Commission (CEA). This new organization has been experimented since the end of year 2000. During the first semester of year 2002, the CEA nuclear inspection team, who is in charge of the control function at the CEA general administration level, has performed an inquiry to check the effectiveness of the new organization. The conclusions of this inquiry are very positive; a few recommendations are now taken in to account to further improve the efficiency of this organization. (J.P.N.)

  14. CEA - Assessment of risk management for 2012

    International Nuclear Information System (INIS)

    Bonnevie, Edwige

    2013-06-01

    This report proposes an overview of the main events, actions performed by the CEA, and facts for 2012 regarding protection and monitoring of the environment, installation safety, occupational health and safety, radiological protection of workers, transportation of hazardous materials, waste management, protection of sites, installations and heritage, emergency situation management, legal risk management, internal controls and audits. It also presents the organisation and action of the risk management department within the CEA

  15. CEA 2009 annual report

    International Nuclear Information System (INIS)

    2010-01-01

    After an indication of several key figures about the activity of the CEA (Centre d'Etudes Atomiques) and its relationship with the academic as well as the industrial field, in France and worldwide, this 2009 annual report presents its various research programs in the field of defence and of global security: basic research (nuclear weapons and propulsion, struggle against proliferation and terrorism) and applied research (nuclear deterrence, national and international security). Then, it presents the programs in the field of de-carbonated energy: basic research (in material science and in life sciences) and applied research (fission energy, fusion energy, new energy technologies). A last group of research programs deals with information and health technologies and concerns life and material sciences, micro- and nano-technologies, software technologies. Interaction with other research institutions and bodies is also evoked. A brief scientific assessment is proposed. Finally, the different structures building the CEA are presented

  16. Tumor, serum and urine carcinoembryonic antigen (CEA) in upper urinary tract urothelial cancer

    International Nuclear Information System (INIS)

    Stefanovic, V.; Ignjatovic, M.

    1987-01-01

    The aim of this investigation was to study the possible diagnostic value of a CEA test in cancer of the renal pelvis and ureter. Thirty-eight patients with upper urinary tract cancer, 15 patients with transitional cell carcinoma of the bladder, 6 kidney carcinoma patients and 25 healthy adults were studied. CEA was determined in tumor tissue, serum and urine, by using a monoclonal radioimmunoassay. Increased serum CEA level was found in 7 out of 27 patients (26%) with active cancer of the renal pelvis and ureter. None of 11 patients with inactive cancer had an increased serum CEA level. No significant correlation was found between the serum CEA level and the histological grading. The tumor CEA content varied markedly, from values obtainted in normal urothelium up to 840 ng/g wet weight. CEA content of tumor tissue did not correlate with the serum level. Our data suggest that serum and urine CEA have not diagnostic accuracy for clinical diagnosis of upper tract urothelial cancer. (orig.) [de

  17. Clinical investigation of serum CEA in 120 patients with colorectal cancer

    International Nuclear Information System (INIS)

    Li Yusheng; Yang Liting; Yu Yunyun; Yu Suqing; Ma Shuqin

    2003-01-01

    To investigate the correlation between serum CEA and colorectal cancer, the pre-and postoperative serum CEA in 120 patients with colorectal cancer was measured by RIA, with other 24 cases of healthy donors as control. The results showed that serum CEA in control group and patient group were 9.84±2.44 ng/mL, 38, 85±19.21 ng/mL respectively, while colonic cancer group 37.43±18.58 ng/mL, rectal cancer group 39.72±20.67 ng/mL. There was significant difference between patient group and control group (P 0.05). Serum CEA of 37 among 44 cases with positive CEA findings decreased to 11.21±3.65 ng/mL during two months follow-up post-operation, whereas 50.63±24.38 ng/mL in 7/44 cases undergoing non-radical operation. The serum CEA of 41 recurrence cases was 43.12±17.15 ng/mL at six-year post-operation, with 87.80% of three-year recurrence rate. It suggested that the serum CEA test is a convenient method for colorectal cancer to preoperatively diagnose it, evaluate postoperative curative effect and detect tumor recurrence and metastasis

  18. The opening of the CEA to the general public

    International Nuclear Information System (INIS)

    Deloche, Robert

    1999-01-01

    Full text: The relationships between science and society have evolved considerably over the past years, just like the perception of the nuclear industry in the French public opinion. Recent psychosociological surveys show that only half of the French population is familiar with the CEA and that the public would like to obtain new elements of judgment in order to be able to develop a direct appreciation of the activities of a research organization such as the Atomic Energy Commission. It is essential to meet the public's expectations, to keep it properly informed of the CEA's research activities, and to help it understand the relevance of the results obtained and the solutions offered to decision-makers, i.e. industrialists and public authorities. One way to answer the public opinion's questions and to meet its expectations is to allow a rowing number of visitors to see who we are, what we study in our laboratories, and how we work to contribute to scientific progress and to the diffusion of technology, in a manner that is useful to society as a whole. This describes the spirit and the objective that governed the very idea and elaboration of the program entitled 'Opening of the CEA to the general public'. This operation consists not only in having communication specialists guide visitors throughout the facilities and equipment of the CEA, but also in encouraging researchers and groups of visitors to meet in the laboratories. A 'CEA - communication' network is under construction. It already has nearly 600 members. Communication is considered to be a real calling that falls within the scope of the CEA's strategy, and the work accomplished in this respect is recognized to the same extent as research. To this end, a charter for the CEA - communication network will be signed by every contributor and manager. A training scheme focused on public speaking and scientific vulgarization was initiated. 50 members of the network have already been trained, and 250 will be in 1999

  19. In vivo localization of radiolabeled monoclonal antibody to carcinoembryonic antigen (CEA) in a CEA-producing tumor

    International Nuclear Information System (INIS)

    Kamei, Tetsuya; Seto, Hikaru; Taki, Kuniyasu; Soya, Toshio; Kakishita, Masao; Maeda, Masatoshi; Honda, Takashi; Koshimura, Saburou.

    1987-01-01

    To compare accumulation of the 125 I-labeled antibodies(anti-carcinoembryonic antigen(CEA) monoclonal antibody and polyclonal antibody) to a CEA-producing tumor (SC-2-JCK), an in vivo localization study was performed in nude mice. The tumor-to-blood ratio at 120 hours after injection rose to 4.6 for the monoclonal antibody, but remained at 1.3 for the polyclonal antibody. However, no differences were noted between the antibodies up to 72 hours after injection. In autoradiograms, selective accumulation of the tracer was noted in the tumor for both antibodies. However, no superiority or inferiority of imaging for either of the antibodies could be definitely determined. (author)

  20. Press tour Siloe CEA/GRENOBLE; Voyage de presse Siloe CEA/GRENOBLE

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-04-01

    The experimental reactor, Siloe, has been stopped the 23 december 1997. This paper of the Cea Grenoble, presents the historical aspects of this reactor and its missions. It gives then a global description of the stopping and dismantling procedure, with the planning, the financing and the human impacts of the operation. The wastes management is also takes into account. (A.L.B.)

  1. Fusion technology. Annual report of the. Association Cea/EURATOM

    International Nuclear Information System (INIS)

    Magaud, P.; Le Vagueres, F.

    1996-01-01

    In 1996, the French EURATOM-CEA Association made significant contributions to the European technology programme. This work is compiled in this report as follows: the ITER CEA activities and related developments are described in the first section; blankets and material developments for DEMO, long term safety studies are summarised in the second part; the Underlying Technology activities are compiled in the third part of this report. In each section, the tasks are sorted out to respect the European presentation. For an easy reading, appendix 4 gives the list of tasks in alphabetical order with a page reference list. The CEA is in charge of the French Technology programme. Three specific organizational directions of the CEA, located on four sites (see appendix 5) are involves in this programme: Advanced Technologies Direction (DTA), for Material task; Nuclear Reactors Direction (DRN), for Blanket design, Neutronic problems, Safety tasks; Physical Sciences Direction (DSM) uses the competence of the Tore Supra team in the Magnet design and plasma Facing Component field. The CEA programme is completed by collaborations with Technicatome, COMEX-Nucleaire and Ecole Polytechnique. The breakdown of the programme by Directions is presented in figure 1. The allocation of tasks is given in appendix 2 and in appendix 3, the related publications. (author)

  2. Safety precautions in atomic pile control (1962); Securite dans le controle des piles atomiques (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Furet, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    We have been led to study the problem of safety in atomic pile control as a result of our participation on the one hand in the planning of C.E.A. atomic piles, and on the other hand in the pile safety sub omission considering atomic pile safety of operational or planned C.E.A. piles. We have thus had to consider the wishes occurring in piles during their operation and also their behaviour in the dynamic state The present work deals mainly with the importance of intrinsic safety devices, with the influence of reactivity variations on the power fluctuations during accidental operation, and with the development of robust and reliable safety appliances. The starting p accident has been especially studied both for low-flux piles where a compromise is necessary between the response time of the safety appliances and the statistical fluctuations and for high lux piles where xenon poisoning has an effect on the lower limit of the velocity of reactivity liberation. The desirability has been stressed of automation as a safety factor in atomic pile control. The details required for an understanding of the diagrams of the apparatus are given. (author) [French] Nous avons aborde le probleme de la securite dans le controle des piles atomiques a la suite de notre participation d'une part aux avant rojets de piles atomiques du CE.A. et d'autre part a l'examen au sein de la sous ommission de surete des piles, de la securite des piles du CE.A. en fonctionnement ou en projet. Nous avons ete amenes a nous interesser alors aux risques encourus par les piles pendant leur fonctionnement et par la meme a leur comportement en regime dynamique. Ce travail traite principalement de l'importance des securites intrinseques, de l'influence des variations de reactivite sur les evolutions de puissance en regime d'accident et du developpement d'appareillages de securite robustes et de fonctionnement tres sur. L'accident de demarrage a ete particulierement developpe aussi bien pour les piles a bas

  3. Safety precautions in atomic pile control (1962); Securite dans le controle des piles atomiques (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Furet, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    We have been led to study the problem of safety in atomic pile control as a result of our participation on the one hand in the planning of C.E.A. atomic piles, and on the other hand in the pile safety sub omission considering atomic pile safety of operational or planned C.E.A. piles. We have thus had to consider the wishes occurring in piles during their operation and also their behaviour in the dynamic state The present work deals mainly with the importance of intrinsic safety devices, with the influence of reactivity variations on the power fluctuations during accidental operation, and with the development of robust and reliable safety appliances. The starting p accident has been especially studied both for low-flux piles where a compromise is necessary between the response time of the safety appliances and the statistical fluctuations and for high lux piles where xenon poisoning has an effect on the lower limit of the velocity of reactivity liberation. The desirability has been stressed of automation as a safety factor in atomic pile control. The details required for an understanding of the diagrams of the apparatus are given. (author) [French] Nous avons aborde le probleme de la securite dans le controle des piles atomiques a la suite de notre participation d'une part aux avant rojets de piles atomiques du CE.A. et d'autre part a l'examen au sein de la sous ommission de surete des piles, de la securite des piles du CE.A. en fonctionnement ou en projet. Nous avons ete amenes a nous interesser alors aux risques encourus par les piles pendant leur fonctionnement et par la meme a leur comportement en regime dynamique. Ce travail traite principalement de l'importance des securites intrinseques, de l'influence des variations de reactivite sur les evolutions de puissance en regime d'accident et du developpement d'appareillages de securite robustes et de fonctionnement tres sur. L'accident de demarrage a ete particulierement

  4. Control of effluents and environmental surveillance of the CEA centres. 1997 status; Controle des rejets et surveillance de l'environnement des centres CEA. Bilan 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    The environmental quality in the vicinity of CEA facilities is a major concern of the safety policy of the CEA. The aim of this document is to inform the public about the gaseous and liquids radioactive effluents released by the CEA centres under the permission of the ministry. It provides a status of the effluents and of the radioactivity levels measured near the CEA centres in 1997, using air, water, vegetation and milk samples. A comparison is made with the measurements performed during the 1993-1996 period. The data presented comes from the regulatory registers transmitted to the agency for the protection against ionizing radiations (OPRI) which belongs to the ministry of health. (J.S.)

  5. Intensified follow-up in colorectal cancer patients using frequent Carcino-Embryonic Antigen (CEA) measurements and CEA-triggered imaging : Results of the randomized "CEAwatch" trial

    NARCIS (Netherlands)

    Verberne, C. J.; Zhan, Z.; van den Heuvel, E.; Grossmann, I.; Doornbos, P. M.; Havenga, K.; Manusama, E.; Klaase, J.; van der Mijle, H. C. J.; Lamme, B.; Bosscha, K.; Baas, P.; van Ooijen, B.; Nieuwenhuijzen, G.; Marinelli, A.; van der Zaag, E.; Wasowicz, D.; de Bock, G. H.; Wiggers, T.

    Aim: The value of frequent Carcino-Embryonic Antigen (CEA) measurements and CEA-triggered imaging for detecting recurrent disease in colorectal cancer (CRC) patients was investigated in search for an evidence-based follow-up protocol. Methods: This is a randomized-controlled multicenter prospective

  6. The CEA-industrie Group. Report for 1986

    International Nuclear Information System (INIS)

    1987-01-01

    From the end of 1983, the whole affiliates and participations of CEA are hept by CEA-industry. The group activity is principally in the nuclear field. Cogema and the whole fuel cycle, construction, maintenance, improvement of nuclear power plants, research reactors and naval propulsion boilers and the sector Power plants and nuclear services (Framatome, Technicatome, Intercontrole, Stmi, principally). A non-nuclear sector comes from new techniques or activities developed for the nuclear needs: computer science (CISI), biomedical field (ORIS-industrie), different activities such as ultrafiltration or robotics-productics [fr

  7. Cancer imaging with CEA antibodies: historical and current perspectives.

    Science.gov (United States)

    Goldenberg, D M

    1992-01-01

    This article reviews the history and status of cancer imaging with radiolabeled antibodies against carcinoembryonic antigen (CEA). Although CEA and many other cancer-associated antigens are not distinct for neoplasia, the quantitative increase of these markers in malignant tissues provides a sufficient differential for selective antibody targeting. Animal studies with xenografted human tumors provided the first evidence of the prospects of this technology, followed by initial clinical success with purified goat whole IgG antibodies to CEA, labeled with 131I and with the use of dual-isotope subtraction methods. Subsequently, improved and earlier imaging could be accomplished with monoclonal antibody fragments, which then would permit the use of shorter-lived radionuclides, such as 111In, 123I, and 99mTc. The preferred use of a monoclonal anti-CEA IgG Fab' fragment, labeled with 99mTc by a recently developed, simple and rapid kit, has enabled the detection of small lesions, including those in the liver, within 4 h of injection. By means of SPECT imaging, a high sensitivity and specificity for RAID could be achieved.

  8. Postoperative serum CEA level as predictive factor for survival in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Lemberger, J.J.; Bogar, M.L.; Takacs Kucsera, M.F.; Csernetics, I.F.

    2002-01-01

    Aim: It is known that routine follow-up of patients with resected colorectal cancer includes serial CEA determinations. In this retrospective study we have investigated relationship between CEA level and survival and whether achieved results enable differentiation of tumors with slow and rapid growth. Material and Methods: Mainly between 1995 and 1999 periodic CEA determination by IRMA were performed in 269 patients after curative resection of colorectal carcinoma. Number of CEA determination/patient were 2-16(median 6). Survival ranged 4,5 and>249,7 months. Based on CEA results patients were divided in group with normal (<10ng/ml) and elevated (=10ng/ml) values regardless of postoperative treatment. Survival curves were computed by Kaplan-Meier method and difference was evaluated by logrank test and difference between proportions. Results:Normal end elevated CEA was found in 193 and 76 patients, respectively. The difference of survival curves between patients with normal and elevated CEA are highly significant (p<0,0001). However, only 10 months after tumor resection is the difference between survived proportions significant suggesting already presence of CEA produced micrometastases contributing to progression of neoplastic process. The mean survival time at normal and elevated CEA values are 142,54±17,86(median 128,60±24,04) and 34,15±4,28 (median 25,20±1,97) months, respectively. No significant difference of survival was found regarding tumor localization. Conclusion:The results show that with regard to CEA level it is possible to divide colorectal tumors on marker negative and positive. Marker negative are with slower growth and relatively good prognosis. Marker positive are associated with elevated CEA level and with considerable shorter survival. Postoperative CEA level is valuable parameter in prediction of patient's outcome

  9. Castrofroila: la representación del poder central en la ribera del Cea (siglos X-XII

    Directory of Open Access Journals (Sweden)

    María PÉREZ RODRÍGUEZ

    2016-03-01

    Full Text Available Sin descartar la diversidad de funciones tradicionalmente atribuidas a castros y castillos, en los últimos años se ha incidido sobre todo en su papel como centros de representación del poder. El ejemplo que aquí presentamos viene caracterizado por la fuerte y continua vinculación que se establece entre Castro Froila–Mayorga, en la ribera del Cea, y la autoridad central. A través de las fuentes documentales y arqueológicas sabemos de la existencia de este enclave y de la importante función política que desde él se ejerció, intensificada tras la división del reino a la muerte de Alfonso VII y el recrudecimiento del conflicto entre León y Castilla.

  10. LHC 2008 talks Peut-on voyager dans le temps? (Is time travel possible?)

    CERN Multimedia

    2008-01-01

    Scientific magazines (and sometimes even scientists themselves) regularly talk about the possibility of travelling through time. It has also been the subject of many science-fiction novels. We will first discuss what we mean when we talk about time travel, then explain what contemporary physics has to say about it. Thursday, 12 June 2008 at 8.00 p.m. Peut-on voyager dans le temps ? Etienne Klein Physicist at CEA and Doctor of Philosophy of Science The Globe, first floor No specialist knowledge required. Entrance free. http://www.cern.ch/globe

  11. Evaluation of the nuclear installations safety of the CEA in 1998

    International Nuclear Information System (INIS)

    Laverie, M.

    1999-09-01

    Michel Laverie, Director of the nuclear safety and quality at the Cea, took stoke of the CEA nuclear installations in 1998. After a recall of the nuclear safety policy and organization, the author presents the risks factors bound to the CEA activities as the dismantling, the wastes and the human factors. A last part is devoted to the list of the accidents occurred during 1998 in the nuclear installations. Tables and statistics illustrate this analysis. (A.L.B.)

  12. 15 CFR 950.7 - Center for Environmental Assessment Services (CEAS).

    Science.gov (United States)

    2010-01-01

    ...) The following are examples of CEAS projects and services: (1) CEAS prepares data-based studies and... experiment design, data analysis, and data management support to project managers and produces merged... global oceanographic data base from observations taken during the First GARP Global Experiment (FGGE). (b...

  13. Identification of CEA-interacting proteins in colon cancer cells and their changes in expression after irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Byong Chul [Colorectal Cancer Branch, Research Institute, National Cancer Center, Goyang (Korea, Republic of); Yeo, Seung Gu [Dept. of Radiation Oncology, Soonchunhyang University College of Medicine, Soonchunhyang University Hospital, Cheonan (Korea, Republic of)

    2017-09-15

    The serum carcinoembryonic antigen (CEA) level has been recognized as a prognostic factor in colorectal cancer, and associated with response of rectal cancer to radiotherapy. This study aimed to identify CEA-interacting proteins in colon cancer cells and observe post-irradiation changes in their expression. CEA expression in colon cancer cells was examined by Western blot analysis. Using an anti-CEA antibody or IgG as a negative control, immunoprecipitation was performed in colon cancer cell lysates. CEA and IgG immunoprecipitates were used for liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis. Proteins identified in the CEA immunoprecipitates but not in the IgG immunoprecipitates were selected as CEA-interacting proteins. After radiation treatment, changes in expression of CEA-interacting proteins were monitored by Western blot analysis. CEA expression was higher in SNU-81 cells compared with LoVo cells. The membrane localization of CEA limited the immunoprecipitation results and thus the number of CEA-interacting proteins identified. Only the Ras-related protein Rab-6B and lysozyme C were identified as CEA-interacting proteins in LoVo and SNU-81 cells, respectively. Lysozyme C was detected only in SNU-81, and CEA expression was differently regulated in two cell lines; it was down-regulated in LoVo but up-regulated in SNU-81 in radiation dosage-dependent manner. CEA-mediated radiation response appears to vary, depending on the characteristics of individual cancer cells. The lysozyme C and Rab subfamily proteins may play a role in the link between CEA and tumor response to radiation, although further studies are needed to clarify functional roles of the identified proteins.

  14. Identification of CEA-interacting proteins in colon cancer cells and their changes in expression after irradiation

    International Nuclear Information System (INIS)

    Yoo, Byong Chul; Yeo, Seung Gu

    2017-01-01

    The serum carcinoembryonic antigen (CEA) level has been recognized as a prognostic factor in colorectal cancer, and associated with response of rectal cancer to radiotherapy. This study aimed to identify CEA-interacting proteins in colon cancer cells and observe post-irradiation changes in their expression. CEA expression in colon cancer cells was examined by Western blot analysis. Using an anti-CEA antibody or IgG as a negative control, immunoprecipitation was performed in colon cancer cell lysates. CEA and IgG immunoprecipitates were used for liquid chromatography–tandem mass spectrometry (LC-MS/MS) analysis. Proteins identified in the CEA immunoprecipitates but not in the IgG immunoprecipitates were selected as CEA-interacting proteins. After radiation treatment, changes in expression of CEA-interacting proteins were monitored by Western blot analysis. CEA expression was higher in SNU-81 cells compared with LoVo cells. The membrane localization of CEA limited the immunoprecipitation results and thus the number of CEA-interacting proteins identified. Only the Ras-related protein Rab-6B and lysozyme C were identified as CEA-interacting proteins in LoVo and SNU-81 cells, respectively. Lysozyme C was detected only in SNU-81, and CEA expression was differently regulated in two cell lines; it was down-regulated in LoVo but up-regulated in SNU-81 in radiation dosage-dependent manner. CEA-mediated radiation response appears to vary, depending on the characteristics of individual cancer cells. The lysozyme C and Rab subfamily proteins may play a role in the link between CEA and tumor response to radiation, although further studies are needed to clarify functional roles of the identified proteins

  15. Nondestructive testing at the CEA

    International Nuclear Information System (INIS)

    Colomer, J.; Lucas, G.

    1976-01-01

    The different nondestructive testing methods used at the CEA are presented: X-ray or gamma radiography, X-ray stress analysis, neutron radiography, ultrasonic testing, eddy currents, electrical testing, microwaves, thermal testing, acoustic emission, optical holography, tracer techniques. (102 references are cited) [fr

  16. Analytic catalog for the use of the nuclear physicists; Repertoire analytique a l'usage des physiciens nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R; Barloutaud, R; Bernas, R; Chaminade, R; Cohen, R; Conjeaud, M; Cotton, E; Faraggi, H; Grjebine, T; Laboulaye, H de; Lehmann, P; Leveque, A; Levi, C; Moreau, J; Naggiar, V; Olkowsky, J; Papineau, L; Papineau, L; Prugne, P; Schuhl, C; Szteinsznaider, D; Tzara, C; Valladas, G [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires; Marty, N; Renard, G [College de France, Lab. de Chimie Nucleaire (France)

    1952-07-01

    The problem of the documentation in nuclear physics becomes constantly more complex. Every week brings its share of publications, always more numerous and more varied. To remedy to this problem, we tried, at the Nuclear Physics Services of the CEA, to give to the documentation the character of a collective and systematized work. The present report covers the literature appeared between January 1, 1950 and July 1, 1951. (Volume 1: CEA report number 120; Volume 2: CEA report number 184). (M.B.) [French] Le probleme de la documentation en physique nucleaire devient sans cesse plus complexe. Chaque semaine apporte son lot de publications, toujours plus nombreuses et plus diversifiees. C'est pour essayer de porter remede a cet etat de choses que nous avons essaye, au service de Physique Nucleaire du C.E.A., de donner a la documentation le caractere d'un travail collectif systematise. Le present rapport couvre la litterature parue entre le 1 Janvier 1950 et le 1 Juillet 1951. (Tome 1: Rapport CEA numero 120; Tome 2: Rapport CEA numero 184). (M.B.)

  17. Analytic catalog for the use of the nuclear physicists; Repertoire analytique a l'usage des physiciens nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R.; Barloutaud, R.; Bernas, R.; Chaminade, R.; Cohen, R.; Conjeaud, M.; Cotton, E.; Faraggi, H.; Grjebine, T.; Laboulaye, H. de; Lehmann, P.; Leveque, A.; Levi, C.; Moreau, J.; Naggiar, V.; Olkowsky, J.; Papineau, L.; Papineau, L.; Prugne, P.; Schuhl, C.; Szteinsznaider, D.; Tzara, C.; Valladas, G. [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires; Marty, N.; Renard, G. [College de France, Lab. de Chimie Nucleaire (France)

    1952-07-01

    The problem of the documentation in nuclear physics becomes constantly more complex. Every week brings its share of publications, always more numerous and more varied. To remedy to this problem, we tried, at the Nuclear Physics Services of the CEA, to give to the documentation the character of a collective and systematized work. The present report covers the literature appeared between January 1, 1950 and July 1, 1951. (Volume 1: CEA report number 120; Volume 2: CEA report number 184). (M.B.) [French] Le probleme de la documentation en physique nucleaire devient sans cesse plus complexe. Chaque semaine apporte son lot de publications, toujours plus nombreuses et plus diversifiees. C'est pour essayer de porter remede a cet etat de choses que nous avons essaye, au service de Physique Nucleaire du C.E.A., de donner a la documentation le caractere d'un travail collectif systematise. Le present rapport couvre la litterature parue entre le 1 Janvier 1950 et le 1 Juillet 1951. (Tome 1: Rapport CEA numero 120; Tome 2: Rapport CEA numero 184). (M.B.)

  18. Analytic index for nuclear physicians uses; Repertoire analytique a l'usage des physiciens nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Ballini, R.; Barloutaud, R.; Bernas, R.; Bretonneau, P.; Chaminade, R.; Cohen, R.; Conjeaud, M.; Cotton, E.; Faraggi, H.; Grjebine, T.; Joffre, H.; Laboulaye, H. de; Lesueur, C.; Leveque, A.; Moreau, J.; Naggiar, V.; Papineau, L.; Prugne, P.; Schuhl, C.; Studinowski, FJ.; Netter, F.; Raievski, V.; Valladas, G. [Commissariat a l' Energie Atomique, Lab. du Fort de Chatillon, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires; Marty, N.; Renard, G. [College de France, Lab. de Chimie Nucleaire (France)

    The problem of the documentation in nuclear physics becomes constantly more complex. Every week brings its share of new publications, always more numerous and more varied. To remedy to this facts that we tried, in the service of Nuclear Physics of the CEA, to give to the documentation a character of a collective and systematized work. The present report covers the literature appeared between first January 1950 and first July 1951. (Volume 1: CEA report number 120; Volume 2: CEA report number 184). (M.B.) [French] Le probleme de la documentation en physique nucleaire devient sans cesse plus complexe. Chaque semaine apporte son lot de publications, toujours plus nombreuses et plus diversifiees. C'est pour essayer de porter remede a cet etat de choses que nous avons essaye, au service de Physique Nucleaire du C.E.A., de donner a la documentation le caractere d'un travail collectif systematise. Le present rapport couvre la litterature parue entre le premier Janvier 1950 et le premier Juillet 1951. (Tome 1: Rapport CEA numero 120; Tome 2: Rapport CEA numero 184). (M.B.)

  19. Serum CEA (carcino-embryonic antigen) monitoring after surgery for cancer of the rectum and colon

    International Nuclear Information System (INIS)

    Reginster, J.Y.; Desaive, C.; Collette, J.; Zangerle, P.F.; Denis, D.; Franchimont, P.

    1984-01-01

    Fifty four patients, operated for colorectal cancer have been followed up for 2 to 100 months after surgery by carcino-embryonic antigen (CEA) determinations and classical, clinical, biological, radiological, echographical, isotopical and tomoscanninvestigations. Each new serum sample has been assayed for CEA with previously collected samples within the same patients. This repetition of CEA on the same samples allows to check the good reproducibility of CEA radioimmunoassay (variation coefficient between assay is less than 10%) and to get a complete profile of CEA level evaluation within the same assay. There is a good correlation between clinical evolution and CEA levels. In 42 patients, CEA levels remained or became normal ( 20 ng ml) at the same time or before clinical and/or paraclinical evidences for metastases or local recurrence. These results showed CEA assay in a quantitative parameter to assess the follow-up of colorectal cancer complementary to clinical, biological, radiological, echographical and isotopical criterias [fr

  20. The CEA and nuclear energy applications

    International Nuclear Information System (INIS)

    1980-01-01

    With PWR reactors, CEA has applied a large part of its activities on steam generators, whilst other technical studies have involved components, maintenance, thermo-hydraulics, safety, materials, instrumentation apparatus and controls. For small light-water reactors, studies carried out have led to development of the Thermos Project: demonstrating the validity of urban heating derived from a pool-type reactor. Other studies have involved fast reactors (manufacture of fissile fuel assemblies, contributions toward the development of the Superphenix project and longer-term studies involving the overall breeder line). Finally, studies on the retreatment of irradiated fuels: aside from the retreatment of irradiated fuel programmes, CEA is pursuing its work on the TOR Project (large-scale pilot for retreatment of fast-neutron fuels) [fr

  1. CEA budget in 1982

    Energy Technology Data Exchange (ETDEWEB)

    1981-12-01

    In 1982, the amount of the CEA budget will be 13.4 billions French Francs. The main characteristics are the priority for employment and investments. In this budget programs are adapted to fit R and D to the government policy: innovation, industrial valorization and fundamental research especially thermonuclear fusion and in the electronuclear field to safety, reprocessing and radioactive waste management.

  2. Big Data solution for CTBT monitoring: CEA-IDC joint global cross correlation project

    Science.gov (United States)

    Bobrov, Dmitry; Bell, Randy; Brachet, Nicolas; Gaillard, Pierre; Kitov, Ivan; Rozhkov, Mikhail

    2014-05-01

    Waveform cross-correlation when applied to historical datasets of seismic records provides dramatic improvements in detection, location, and magnitude estimation of natural and manmade seismic events. With correlation techniques, the amplitude threshold of signal detection can be reduced globally by a factor of 2 to 3 relative to currently standard beamforming and STA/LTA detector. The gain in sensitivity corresponds to a body wave magnitude reduction by 0.3 to 0.4 units and doubles the number of events meeting high quality requirements (e.g. detected by three and more seismic stations of the International Monitoring System (IMS). This gain is crucial for seismic monitoring under the Comprehensive Nuclear-Test-Ban Treaty. The International Data Centre (IDC) dataset includes more than 450,000 seismic events, tens of millions of raw detections and continuous seismic data from the primary IMS stations since 2000. This high-quality dataset is a natural candidate for an extensive cross correlation study and the basis of further enhancements in monitoring capabilities. Without this historical dataset recorded by the permanent IMS Seismic Network any improvements would not be feasible. However, due to the mismatch between the volume of data and the performance of the standard Information Technology infrastructure, it becomes impossible to process all the data within tolerable elapsed time. To tackle this problem known as "BigData", the CEA/DASE is part of the French project "DataScale". One objective is to reanalyze 10 years of waveform data from the IMS network with the cross-correlation technique thanks to a dedicated High Performance Computer (HPC) infrastructure operated by the Centre de Calcul Recherche et Technologie (CCRT) at the CEA of Bruyères-le-Châtel. Within 2 years we are planning to enhance detection and phase association algorithms (also using machine learning and automatic classification) and process about 30 terabytes of data provided by the IDC to

  3. Demonstration of monoclonal anti-carcinoembryonic antigen (CEA) antibody internalization by electron microscopy, western blotting and radioimmunoassay.

    Science.gov (United States)

    Tsaltas, G; Ford, C H; Gallant, M

    1992-01-01

    One of the important factors affecting the action of monoclonal antibodies (Mabs) or immunoconjugates on tumour sites depends on whether the Mab is internalized by the cancer cells in question. The underexplored subject of internalization is discussed in this paper, and a number of in vitro techniques for investigating internalization are evaluated, using a model which consists of a well characterized anti-carcinoembryonic antigen (anti-CEA) Mab and a number of CEA expressing human cancer cell lines. Employing two alternative radiolabeling assays, evidence for internalization of the anti-CEA Mab by a CEA-positive colorectal cancer cell line (LS174T) was obtained throughout the time intervals examined (5 min to 150 min). Electronmicroscopy employing horseradish-peroxidase labeled anti-CEA Mab and control antibody permitted direct visualization of anti-CEA Mab-related staining in intracellular compartments of a high CEA-expressor human colorectal cell line (SKCO1). Finally Western blots of samples derived from cytosolic and membrane components of solubilized cells from lung and colonic cancer cell lines provided evidence for internalized anti-CEA Mab throughout seven half hour intervals, starting at 5 minutes. Internalized anti-CEA was detected in all CEA expressing cell lines (LS174T, SKCO1, BENN) but not in the case of a very low CEA expressor line (COLO 320).

  4. Regarding the old Cea factory of the Bouchet

    International Nuclear Information System (INIS)

    Anon

    1997-10-01

    This article si devoted to the Cea site of the Bouchet. Radiation monitoring have been made and the information about it, given to the populations around the site. The wastes with a value upper than this one chosen for low activity wastes have been sent to the storage center of Manche plant, the other ones whom activity level was lower than this one advocated for low level radioactive wastes were used for the base of A87 motorway. The two little rivers have been cleaned out and the sediments tipped out in the decantation basin of the Cea site. Radiation monitoring for the radon have to be made to control the right progress of these decontamination operations. All these operations have been made in dialogue with S.N.P.E.( the national society of powders and explosives), the D.R.I.R.E.( regional direction of research industry and environment), O.P.R.I. (office of protection against ionizing radiations) and the Cea. (N.C.)

  5. Rosácea fulminante: relato de caso

    Directory of Open Access Journals (Sweden)

    José Otávio Alquezar Gozzano

    2016-10-01

    Full Text Available Introdução: Rosácea fulminante (RF ou pioderma facial é uma doença rara, descrita em 1940 por Kierland e O’Leary. É considerada uma variante extrema de rosácea conglobata, esta, consiste em formação de placas e abscessos hemorrágicos na pele. A RF tem sua etiologia desconhecida, porém há teorias que relacionam seu acometimento com a variação de hormônios femininos e a ingestão de vitamina B12. A RF é frequente em mulheres, principalmente pós- adolescentes. Apresenta-se abruptamente na face, amiúde na região mento- mandibular, através de pápulas inflamatórias, pústulas, cistos e nódulos com comedões escassos ou inexistentes, além de abcessos, sem manifestações sistêmicas e com a recidiva rara. Seu diagnóstico é fundamentalmente clínico, apenas com a história do paciente, sem necessidade de exames complementares. Para o tratamento, são utilizados corticoides orais, isotretinoína oral e antibióticos a fim de minimizar as sequelas físicas e psicológicas. Objetivo: Relatar caso de paciente com diagnóstico de rosácea fulminante. Metodologia: Paciente diagnosticada com rosácea fulminante atendida em serviço ambulatorial e revisão de literatura. Relato de caso: Paciente do sexo feminino, 19 anos, refere lesões súbitas em face há uma semana. Nega quadro acneico anterior, histórias de alergias e outras comorbidades. Relata ausência de uso de anticoncepcionais orais há 5 meses e data de última menstruação há 3 semanas, sem atraso menstrual. Ao exame: pápulas eritematosas e pústulas, além de pequenos nódulos inflamatórios na face. Hipótese diagnóstica: RF. Como conduta, foi prescrito tetraciclina. Conclusões: A RF é uma forma infrequente de rosácea, sendo importante o diagnóstico precoce e tratamento eficaz, a fim de melhorar a qualidade de vida do paciente.

  6. Control of effluents and environmental surveillance of the CEA centres. 1997 status

    International Nuclear Information System (INIS)

    1998-06-01

    The environmental quality in the vicinity of CEA facilities is a major concern of the safety policy of the CEA. The aim of this document is to inform the public about the gaseous and liquids radioactive effluents released by the CEA centres under the permission of the ministry. It provides a status of the effluents and of the radioactivity levels measured near the CEA centres in 1997, using air, water, vegetation and milk samples. A comparison is made with the measurements performed during the 1993-1996 period. The data presented comes from the regulatory registers transmitted to the agency for the protection against ionizing radiations (OPRI) which belongs to the ministry of health. (J.S.)

  7. Network and system diagrams revisited: Satisfying CEA requirements for causality analysis

    International Nuclear Information System (INIS)

    Perdicoulis, Anastassios; Piper, Jake

    2008-01-01

    Published guidelines for Cumulative Effects Assessment (CEA) have called for the identification of cause-and-effect relationships, or causality, challenging researchers to identify methods that can possibly meet CEA's specific requirements. Together with an outline of these requirements from CEA key literature, the various definitions of cumulative effects point to the direction of a method for causality analysis that is visually-oriented and qualitative. This article consequently revisits network and system diagrams, resolves their reported shortcomings, and extends their capabilities with causal loop diagramming methodology. The application of the resulting composite causality analysis method to three Environmental Impact Assessment (EIA) case studies appears to satisfy the specific requirements of CEA regarding causality. Three 'moments' are envisaged for the use of the proposed method: during the scoping stage, during the assessment process, and during the stakeholder participation process

  8. Aeroacoustics research in Europe : the CEAS-ASC report on 1997 highlights

    NARCIS (Netherlands)

    Rienstra, S.W.

    1998-01-01

    This paper is a report on the highlights of aeroacoustics research and development in Europe in 1997, compiled from information provided in the CEAS Aeroacoustics Specialists Committee (ASC). The Confederation of European Aerospace Societies (CEAS) comprises the national Aerospace Societies of

  9. Carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Ephraim, K.H.; Cox, P.H.; Hamer, C.J.A. v.d.; Berends, W.; Delhez, H.

    1977-01-01

    The carcinoembryonic antigen (CEA) is a complex of antigen determinants and also the carrier of these determinants. Chemically it is a glycoprotein. Its occurrence in blood serum or urine is correlated with malignant disease. Several radioimmunoassays (RIA) have been developed, one by Hoffmann-Laroche and one by the Rotterdam Radiotherapeutic Institute. Both methods and the Hoffmann assay kit are tested. Specifications are given for isolation of the antigen, preparation of the antiserum, and the execution of the RIA. Biochemical and clinical aspects are discussed

  10. How Packaging Fleet Renewal Fits French CEA Programs

    International Nuclear Information System (INIS)

    Dumesnil, J.; Malvache, P.; Hugon, F.C.; Sollacaro, M.

    2006-01-01

    CEA's (French Atomic Energy Agency) packaging fleet is dedicated to transportation of test irradiated fuels, of research reactors fuels, of navy propulsion fuels, and of waste coming from and to nuclear plants or facilities. This fleet encompasses more than 30 types of casks ranging from 5 to 30 tons, with either recent designs or other dating back to the seventies. A study has been launched in order to perform a global analysis of the life expectancy of the existing CEA and COGEMA Logistics cask fleets with respect to a 2015 target, in order to anticipate its renewal, while limiting the number of type of cask. Key elements like periodical evolutions of design and transport regulations, lessons learnt of existing casks (design, approval and extensions, operational feedback, maintenance and dismantling) are taken into account in order to ensure compliance and availability of the fleet. Moreover, from design to cask delivery, including regulatory tests, safety analysis report/ CoC, and manufacturing, 3 to 5 years is needed. Therefore cask development should be taken into account earlier of invest and research's programs. The paper will address the current life expectancy study of CEA and COGEMA Logistics packaging fleet, based on lessons learnt and regulation evolution and on general R and D plans by user facilities. It will show how a comprehensive optimized fleet is made available to CEA and other customers. Such a fleet combines optimized investment and uses, thus entailing synergies for well-mastered costs of transports. (authors)

  11. CA 19-9 as a marker in addition to CEA to monitor colorectal cancer.

    Science.gov (United States)

    Stiksma, Jolanda; Grootendorst, Diana C; van der Linden, Peter Willem G

    2014-12-01

    Carcinoembryonic antigen is the commonly used tumor marker in patients with colorectal cancer, and CA 19-9 might be an additional marker. The aim of this retrospective study was to investigate whether CA 19-9 levels can be used to monitor the disease process in patients with colorectal cancer who had no elevated CEA levels. The secondary aim was to determine if preoperative increased levels of CEA and CA 19-9 were associated with mortality. Two sets of data from patients with histologically confirmed colorectal cancer, were included in a single-center study. First, patients with a minimum of 3 serial measurements of CA 19-9 and CEA tumor markers were related to the clinical course of their disease. Second, patients with preoperative levels of CEA and CA 19-9 were related to survival. In patients with colorectal cancer and 3 serial measurements of tumor markers, 7.3% had only increased CA 19-9 levels without increased CEA levels, and 55.4% of the patients had an increase of CA 19-9 and CEA levels. In the patients with available preoperative markers, patients with only an increase of CA 19-9 had a significantly decreased 5-year survival compared with patients with an increase of only CEA (P = .013). CA 19-9 can be used as additional marker to follow the disease process in patients with colorectal cancer without an increase in CEA level. Patients with preoperative increased CA 19-9 level had a poorer 5-year survival than patients with preoperative increased CEA levels. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. CEA 2011, a look back at a year of research

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    For this year 2011, marked by the Fukushima accident, the goal is improved safety. This is a key issue being addressed by CEA, while at the same time boosting its R and D on low-carbon energies, defense and security, Health technologies, information technologies and very large research Infrastructures. With more than 650 priority patents filed in 2011, CEA maintains its position as the leading French research organization. CEA stands in 4. place among the European research organizations, in terms of the number of projects (535, including 70 that it coordinates) and financing obtained (nearly euros 55 M) under the European Commission's FP7 framework programme. CEA's civil programs are 30% funded from external revenues (partner companies, national incentive funds, local authorities and European Union), 49% from the Government and, finally, 21% from two funds dedicated to clean-up of civil and defense facilities. Of the euros 1, 391 M devoted to low-carbon energies, research into the new energy technologies and nuclear systems of the future each received a budget of euros 151 M in 2011. CEA plays a key role in the European Energy Research Alliance, as a founding member, a member of the executive committee and a member of the secretariat. It is France's representative. EERA has launched 13 joint programs, including 6 in 2011. It pools the research efforts of more than 150 institutes and universities, with more than 2, 000 staff employed full-time. CEA is present in 8 programs, with 100 full-time staff, in other words 5% of the total partner commitment. This special issue of 'Defis du CEA' journal deals with the main results of the researches carried out in 2011 at the CEA. Contents: 1 - Facts and figures 2011: Intellectual Property, European Financing, Budget, Nuclear Safety, European Research Programs, International Relations, International Collaboration, Spin-off, Scientific Excellence, Training; 2 - Low-carbon energies: Biofuels, Solar

  13. CEA 2011, a look back at a year of research

    International Nuclear Information System (INIS)

    2011-01-01

    For this year 2011, marked by the Fukushima accident, the goal is improved safety. This is a key issue being addressed by CEA, while at the same time boosting its R and D on low-carbon energies, defense and security, Health technologies, information technologies and very large research Infrastructures. With more than 650 priority patents filed in 2011, CEA maintains its position as the leading French research organization. CEA stands in 4. place among the European research organizations, in terms of the number of projects (535, including 70 that it coordinates) and financing obtained (nearly euros 55 M) under the European Commission's FP7 framework programme. CEA's civil programs are 30% funded from external revenues (partner companies, national incentive funds, local authorities and European Union), 49% from the Government and, finally, 21% from two funds dedicated to clean-up of civil and defense facilities. Of the euros 1, 391 M devoted to low-carbon energies, research into the new energy technologies and nuclear systems of the future each received a budget of euros 151 M in 2011. CEA plays a key role in the European Energy Research Alliance, as a founding member, a member of the executive committee and a member of the secretariat. It is France's representative. EERA has launched 13 joint programs, including 6 in 2011. It pools the research efforts of more than 150 institutes and universities, with more than 2, 000 staff employed full-time. CEA is present in 8 programs, with 100 full-time staff, in other words 5% of the total partner commitment. This special issue of 'Defis du CEA' journal deals with the main results of the researches carried out in 2011 at the CEA. Contents: 1 - Facts and figures 2011: Intellectual Property, European Financing, Budget, Nuclear Safety, European Research Programs, International Relations, International Collaboration, Spin-off, Scientific Excellence, Training; 2 - Low-carbon energies: Biofuels, Solar Photovoltaic, Nuclear, Energy

  14. Étude de l'effet modérateur de sels sur la réaction sodium-eau, pour le "lavage" d'assemblages de combustible irradiés issus de réacteurs à caloporteur sodium

    OpenAIRE

    Lacroix , Marie

    2014-01-01

    Within the framework of the development of generation IV reactors one of the research tracks is related to the development of fast neutron reactors using fluid sodium heat transfer...; Dans le cadre du développement des réacteurs de génération IV, une des voies de recherche concerne le développement des réacteurs à neutron rapide à caloporteur sodium. Le CEA a pour projet la construction d'un prototype de réacteur de ce type appelé " ASTRID ". En réponse aux besoins de développement de ce pro...

  15. Balance 2003 of the risks control at the Cea

    International Nuclear Information System (INIS)

    2004-07-01

    As a research center on the energy, the information and health technologies and the defense, the Cea activities are indissociable from the risk control notion. To organize the risks management, the Cea decided to create in july 2003 a special pole of risks control and management. This presentation is based on some major topics of the risks control: the environmental impact control, the occupational risks control, the installations safety control and the hazardous matter transport control. (A.L.B.)

  16. The Prognostic Significance of Pretreatment Serum CEA Levels in Gastric Cancer: A Meta-Analysis Including 14651 Patients

    Science.gov (United States)

    Deng, Kai; Yang, Li; Hu, Bing; Wu, Hao; Zhu, Hong; Tang, Chengwei

    2015-01-01

    Background Carcinoembryonic antigen (CEA) is commonly used as a serum tumor marker in clinical practice; however, its prognostic value for gastric cancer patients remains uncertain. This meta-analysis was performed to assess the prognostic value of CEA and investigate CEA as a tumor marker. Methods PubMed, EMBASE and other databases were searched for potentially eligible studies. Forty-one studies reporting the prognostic effect of pretreatment serum CEA expression in gastric cancer patients were selected. Data on 14651 eligible patients were retrieved for the meta-analysis. Based on the data extracted from the available literature, the hazard ratio (HR) and 95% confidence interval (CI) for an adverse prognosis were estimated for gastric cancer patients with elevated pretreatment serum levels of CEA (CEA+) relative to patients with normal pretreatment CEA levels (CEA-). Results The CEA+ patients had a significantly poorer prognosis than the CEA- patients in terms of overall survival (OS: HR 1.716, 95% CI 1.594 - 1.848, P 0.05). In the pooled analyses of multivariate-adjusted HRs, the results suggested that pretreatment serum CEA may be an independent prognostic factor in gastric cancer (OS: HR 1.681, 95% CI 1.425 - 1.982; DSS: HR 1.900, 95% CI 1.441 - 2.505; DFS: HR 2.579, 95% CI 1.935 - 3.436). Conclusion/Significance The meta-analysis based on the available literature supported the association of elevated pretreatment serum CEA levels with a poor prognosis for gastric cancer and a nearly doubled risk of mortality in gastric cancer patients. CEA may be an independent prognostic factor for gastric cancer patients and may aid in determining appropriate treatment which may preferentially benefit the CEA+ patients. PMID:25879931

  17. Clinical Significance of Plasma CEA Levels in the Patients with Cervical Carcinoma during Follow-Up

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Sung Beom; Kim, Joo Young; Choi, Myung Sun; Rha, Joong Yeol; Lee, Min Jae [Korea University College of Medicine, Seoul (Korea, Republic of)

    1991-12-15

    Carcinoembryonic antigen (CEA) has been studied in the field of gynecologic malignancy to determine whether it can be used as a tumor marker for early detection of recurrence or evaluation of therapeutic results. From January 1985 through December 1989, a total of 239 cervical cancer patients were entered for an analysis of plasma CEA level in the group with cervical cancer compared to the control group consisting of 65 normal healthy women and 18 women with benign gynecologic disease. Plasma CEA levels appear to be directly related with the tumor extension and as stages advance, the incidence of patients with abnormal plasma CEA levels is increased. Also, there seems to be a little higher incidence of abnormal CEA levels in patients with adenocarcinomas or adenosquamous carcinoma but not statistically significant because of small number of patients. When the patients developed recurrence, plasma CEA levels are markedly elevated in the majority, particularly in patients with hepatic metastases. In conclusion, serial plasma CEA checks could be used to detect recurrence during follow-up after treatment of cervical cancer.

  18. Scientific evaluation at the French Atomic Energy Commission (CEA). 2005-2006 annual report

    International Nuclear Information System (INIS)

    2006-01-01

    This report aims at presenting the scientific evaluation activities carried out at the CEA during the years 2005-2006. The evaluation system is described in detail. It comprises two aspects: the evaluation of the scientific policy implemented by the scientific Council and by the visiting committee of the CEA, and the evaluation of the laboratories, performed by a pool of 36 scientific councils. The evaluation by external and independent parties is the key point of this system. This document makes a status of the evaluations performed in 2005 and 2006. It presents a synthesis of the conclusions of the evaluation authorities. The actions implemented by the CEA to take into consideration the recommendations are also reported with the improvements noticed. The two topics examined by the scientific Committee and by the visiting committee were dealing with the energy domain, which is a strategic issue for the CEA. The examination of the researches on future nuclear reactors and on new energy technologies have shown the major role played by the CEA in the recent advances in these domains. About 95% of the laboratories activity was examined during the 2002-2005 period. The richness of the remarks and recommendations made by the scientific councils should allow the CEA to improve the quality and relevance of its research works. The start-up of the 2006-2009 evaluation cycle has been the occasion to modify the evaluation of some research domains in order to take into account the evolution of programs. The evaluation system of the CEA is highly consistent with the AERES principles. Its implementation, adapted to each type of activity (fundamental research, applied research, technological developments) allows the CEA to follow up a permanent improvement approach. (J.S.)

  19. A three-dimensional pin-wise analysis for CEA ejection accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Guen-Tae; Park, Min-Ho; Park, Jin-Woo; Um, Kil-Sup; Choi, Tong-Soo [KEPCO NF, Daejeon (Korea, Republic of)

    2016-10-15

    The ejection of a control element assembly (CEA) with high reactivity worth causes the sudden insertion of reactivity into the core. Immediately after the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the doppler effect becomes important and turns the reactivity balance and power down to lower levels. The 3-D CEA ejection analysis methodology has been developed using the multi-dimensional code coupling system, CHASER, which couples three dimensional core neutron kinetics code ASTRA, subchannel analysis code THALES, and fuel performance analysis code FROST using message passing interface (MPI). This paper presents the pin-by-pin level analysis result with the 3-D CEA ejection analysis methodology using the CHASER. The pin-by-pin level analysis consists of DNBR, enthalpy and Pellet/Clad Mechanical Interaction (PCMI) analysis. All the evaluations are simulated for APR1400 plant loaded with PLUS7 fuel. In this paper, the pin-by-pin analysis using the multidimensional core transient code, CHASER, is presented with respect to enthalpy, DNBR and PCMI for APR1400 plant loaded with PLUS7 fuel. For the pin-by-pin enthalpy and DNBR analysis, the quarter core for HFP case or 15 - 20 assemblies around the most severe assembly for part powers or HZP cases are selected. And PCMI calculation is performed for all the rods in the whole core during a conservative time period. The pin-by-pin analysis results show that the regulatory guidelines of CEA ejection accident are satisfied.

  20. Nuclear energy in France. Respective part of CEA, EDF, FRAMATOME

    International Nuclear Information System (INIS)

    Graf, J.J.

    1976-01-01

    In France, the three actors on the nuclear stage are CEA, EDF, and industry. The CEA, important organism of research and development, represents the public power, counsels the Government for safety and constitutes the State interference by the indirect mean of budget which is assigned to it. The industry, FRAMATOME, is commissioned to build plants. EDF has vocation to provide electricity at the lower costs [fr

  1. How to Add Value to your Business with CEA: A Practical Approach

    Directory of Open Access Journals (Sweden)

    Daniel Cardenas

    2010-04-01

    Full Text Available Companies are always trying to differentiate themselves from the rest of the pack by applying different strategies such as improving customer service, increasing the efficiency of their operations, or reducing their costs. Most of the time, however, these goals are competing against each other for scarce resources, and managers often need to decide to concentrate on one. A small company can effectively and simultaneously accomplish these goals for a fraction of the cost by implementing communications-enabled business processes or solutions, which are a set of technology components that add real-time networking functionality to applications. One particular implementation of this framework is the one provided by Coral CEA. Coral CEA is a business ecosystem anchored around CEA functionalities that are offered as building blocks, out-of-the-box components that link the capabilities and intelligence of networks platforms with the power of current applications to provide a new set of features and functionalities. In this article, we show how a small company called Rezact, located in the ski resort town of Mont-Tremblant, Quebec, successfully implemented CEA capabilities within its own operations using Coral CEA services.

  2. Diagnostic test pepsinogen I and combination with tumor marker CEA in gastric cancer

    Science.gov (United States)

    Sembiring, J.; Sarumpaet, K.; Ganie, R. A.

    2018-03-01

    Gastric cancer (GC) is the fifth leading cause of cancer and the third leading cause of cancer-related mortality globally. Human pepsinogens (HP) are considered promising serological biomarkers for the screening of atrophic gastritis (AG) and GC. HP are biochemically and immunochemically classified into two groups: pepsinogen I (PG I) and PG II. Carcinoembryonic antigen (CEA) is a glycoprotein, which is present in normal mucosal cells but increased amounts are associated with adenocarcinoma, especially colorectal cancer. CEA in combination with other tumour markers can be used in pre-operative staging and thereby assist in the planning of the type of surgery required and future management options. The purpose of this study was to diagnose test PG I and combination with tumor marker CEA in 32 patients suspected with GC. There was a significant difference in levels of CEA between GC group with non-GC with a value p <0.001. PGI sensitivity was 70.58% and specificity 93.3%. The sensitivity of PGI and CEA combination of 94.1% and specificity 80%. The area of AUC obtained was 92.7% at 95% confidence interval (82.7-100%). This AUC value indicated that the value of diagnostic accuracy of the PGI and CEA combinations of 92.7%.

  3. Physical protection of nuclear materials and facilities in CEA

    International Nuclear Information System (INIS)

    Garnier-Gratia, M.-H.; Jorda, A.

    2001-01-01

    Full text: CEA (Commissariat a l'Energie Atomique), as nuclear operator, is responsible for the control and protection of their nuclear materials. Inside CEA, DCS (Central Security Division) is in charge of the security matters, DCS defines the CEA strategy in this field, especially in physical protection. The paper will present the physical protection strategy of CEA. DCS defines the rules and methods; the operators have to apply in order to fulfill the security objectives of CEA. CEA has to provide the regulatory authority with documents proving that it is in accordance with the requirements of the 25th July 1980 law and 12th May 1981 decree. It has to implement all the necessary means in order to achieve the results requested by the regulatory authority. All these arrangements are described in the 'license and control file'. This file should specify the facility safeguards and physical protection system. Accounting measures are also described. In this file, the petitioner has to justify its capacity for holding nuclear materials and for exercising authorized activities on them. So the organization and the installed means have to be described in this authorization file. For physical protection, containment, surveillance and physical protection measures are presented: Containment measures must prevent the unauthorized or unjustified movements of nuclear material in the framework of the authorized activities; Surveillance measures must guarantee the integrity of the containment, check that no material is exiting by an abnormal channel; Physical protection measures for the materials, the premises and the facilities are intended to protect them against malevolent actions by means of security systems. The Central Security Division has established guidelines to provide guidance to the nuclear materials holders in writing such files. Each holding unit has to establish a 'license and control file' and each CEA site establishes a 'site license and control file

  4. Prognostic impact of carcinoembryonic antigen (CEA) on patients with metastatic pancreatic cancer: A retrospective cohort study.

    Science.gov (United States)

    Imaoka, Hiroshi; Mizuno, Nobumasa; Hara, Kazuo; Hijioka, Susumu; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Hirayama, Yutaka; Hieda, Nobuhiro; Yoshida, Tsukasa; Okuno, Nozomi; Shimizu, Yasuhiro; Niwa, Yasumasa; Yamao, Kenji

    2016-01-01

    Carcinoembryonic antigen (CEA) is one of the most widely used tumor markers, and its level is increased in 30-60% of patients with pancreatic cancer (PC). However, little is known about the implications of CEA as a prognostic marker in metastatic PC. The purpose of this study was to examine the usefulness of CEA levels as a prognostic marker in patients with metastatic PC. We conducted a retrospective cohort study using data from a computerized database. A total of 433 patients with metastatic disease were analyzed. Median overall survival (OS) was significantly shorter for patients with high CEA (>5 ng/ml) than with normal CEA (≤5 ng/ml) (6.8 vs. 10.3 months, respectively; p CEA level was an independent predictive factor for OS (hazard ratio [HR], 1.81; 95% confidence interval [CI], 1.45-2.26). In the high CEA group, OS in patients treated with combination chemotherapy was similar to that with single-agent chemotherapy (median, 7.1 vs. 6.8 months; HR for OS, 0.99; 95% CI, 0.71-1.40). The present results show that CEA level is an independent prognostic factor in patients with metastatic PC. A combination chemotherapy regimen may offer modest survival benefit in patients with high CEA. Copyright © 2016 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  5. The pre, post brachytherapy and postoperative CEA serum concentration of 53 rectal cancer patients

    International Nuclear Information System (INIS)

    Nguyen Thanh Danh; Nguyen Kim Luu; Phan Van Dan

    2008-01-01

    CEA serum concentration level of 53 rectal cancer patients was measured at moments pre, post brachytherapy (45 Gy), post surgery one week, 6 months and 12 months. Response to radiation with reduce CEA serum concentration was achieved in 20/53 patients (37,7%), mainly at staging Dukes B, C. Postoperative CEA level of patients significantly decreased, especially in resection group. (author)

  6. Hookah smoking and cancer: carcinoembryonic antigen (CEA) levels in exclusive/ever hookah smokers

    OpenAIRE

    Sajid, Khan Mohammad; Chaouachi, Kamal; Mahmood, Rubaida

    2008-01-01

    Abstract Background We have recently published some work on CEA levels in hookah (also called narghile, shisha elsewhere) and cigarette smokers. Hookah smokers had higher levels of CEA than non-smokers although mean levels were low compared to cigarette smokers. However some of them were also users of other tobacco products (cigarettes, bidis, etc.). Objectives To find serum CEA levels in ever/exclusive hookah smokers, i.e. those who smoked only hookah (no cigarettes, bidis, etc.), prepared b...

  7. Preparation of one-vial reduced anti-CEA kit

    International Nuclear Information System (INIS)

    Hamada, Elena Setuko; Muramoto, Emiko; Shiraishi, Emilia Mayumi; Silva, Licia Maria Britto da; Martins, Heidi Pinto; Silva, Constanca Pagano Goncalves da

    1996-01-01

    A rapid and reliable instant reduced anti-CEA lyophilized kit for labelling with 99m Tc was developed. Each vial contains 0.5 mg of reduced anti-CEA, 40 μg of mendronate (MDP), 2.75 μg stannous fluoride (Sn F 2 ) and 15 μ g p-aminobenzoic acid (PABA). Labeling efficiency and stability were higher than 95% and were determined by instant paper chromatography. Biodistribution studies were performed in normal isogenic BALB/c mice at 4,6 and 24 hours after intravenous administration of the radiolabelled product. The maximum amount of activity was accumulated in the liver followed by intestines and kidneys. (author)

  8. The CEA budget in 1982

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    In 1982, the amount of the CEA budget will be 13.4 billions French Francs. The main characteristics are the priority for employment and investments. In this budget programs are adapted to fit R and D to the government policy: innovation, industrial valorization and fundamental research especially thermonuclear fusion and in the electronuclear field to safety, reprocessing and radioactive waste management [fr

  9. The CEA contribution to quality control

    International Nuclear Information System (INIS)

    Rapin, M.; Colomer, J.

    1979-01-01

    The Commissariat a l'Energie Atomique has developed original methods and techniques for testing delicate components of the primary circuit of pressure water reactors. These techniques make use of a very wide range of non destructive testing methods: Eddy currents, particularly multiple frequencies, for testing steam generator tubes, gudgeon and other pins focused ultrasonics for testing all the welds of the reactor vessel and its cover plate, mixed welds of steam vessels and generators, low welds of the pressurizer and gudgeon pins from the inside. On site use is effected with specific machines intended either for inspecting the tube bundles of steam generators under the responsibility of INTERCONTROLE Co., or for the complete examination of the reactor vessel by mixed CEA/INTERCONTROLE crews under the responsibility of the CEA. All these operations are subjected to a programme of quality assurance that provides the guaranty of execution complying with the procedures in force [fr

  10. A new solid phase enzyme immuno assay using a monoclonal antibody for CEA determinations in patients with various carcinomas

    International Nuclear Information System (INIS)

    Staab, H.J.; Glock, S.; Hornung, A.

    1982-01-01

    The clinical validity of carcinoembryonic antigen (CEA) determination with a new solid phase enzyme immuno assay using a monoclonal antibody (EIA-m) in comparison with a common CEA radioimmunoassay with polyclonal antisera (RIA) was investigated for primary diagnosis in 123 patients with various malignancies and in the postoperative followup of 83 patients with gastrointestinal cancers over a period of about one year. The normal range of the new CEA test in which CEA was directly measured without any further extraction, was calculated from the CEA distribution of 147 healthy blood donors and found to be 0-1.5 μg CEA/l. Besides a very fine reproducibility the CEA-m exhibited a pronounced specificity for CEA from patients with colorectal cancers compared with the RIA. Using a cut-off level of >=1.5 μg CEA/l serum with the EIA-m, the test gave a specificity of 76% with a sensitivity of 72% for preoperative serum specimen of 82 patients with colorectal cancers and a control group of 53 patients with nonmalignant gastrointestinal diseases. In this groups of patients the EIA-m was superior to the RIA test which had a sensitivity of 75% at a specificity of 62% using a threshold of >=2.0 μg CEA/l serum. In the followup studies 3 basic tendencies of the CEA time courses well distinguished from each other could be established for both CEA-Tests. Tumor progression, characterized by steadily increasing CEA levels were evident in 20/23 cases with recurrent disease while decreasing or essentially unchanged CEA levels correlated with NED status in the patients. Furthermore 3/23 cases with metastasis in the followup had initial CEA increases indicated by EIA-m, 3-5 months before this increase of the CEA values was evident with the RIA. Transient CEA elevations, not associated with malignant growth, were found less frequently with the new EIA-m compared to the RIA. (orig.) [de

  11. Special document: which energies for tomorrow? Fossil, renewable, nuclear, hydrogen energies; the CEA of Saclay at the heart of the research; energy, greenhouse effect, climate; Dossier special: quelles energies pour demain? Energies fossiles, renouvelables, nucleaires, hydrogene; le Centre CEA de Saclay au coeur de la recherche; energie, effet de serre, climat

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2003-04-01

    The Cea devotes many research programs in the energy domain and especially in the development of new energetic solutions: hydrogen program, photovoltaic program, energy conservation domain and improvement of energy production systems. In this framework, this document presents synthetical information on the France situation in the world energy space and on the Cea Saclay researches. The energy policy and the electric power in France, the fossil energies, the nuclear energy, the renewable energies, the hydrogen and the fuel cell, the greenhouse effect and the climatology are detailed. (A.L.B.)

  12. 2nd CEAS Specialist Conference on Guidance, Navigation and Control

    CERN Document Server

    Mulder, Bob; Choukroun, Daniel; Kampen, Erik-Jan; Visser, Coen; Looye, Gertjan

    2013-01-01

    Following the successful 1st CEAS (Council of European Aerospace Societies) Specialist Conference on Guidance, Navigation and Control (CEAS EuroGNC) held in Munich, Germany in 2011, Delft University of Technology happily accepted the invitation of organizing the 2nd  CEAS EuroGNC in Delft, The Netherlands in 2013. The goal of the conference is to promote new advances in aerospace GNC theory and technologies for enhancing safety, survivability, efficiency, performance, autonomy and intelligence of aerospace systems using on-board sensing, computing and systems. A great push for new developments in GNC are the ever higher safety and sustainability requirements in aviation. Impressive progress was made in new research fields such as sensor and actuator fault detection and diagnosis, reconfigurable and fault tolerant flight control, online safe flight envelop prediction and protection, online global aerodynamic model identification, online global optimization and flight upset recovery. All of these challenges de...

  13. Usefulness of analytical CEA doubling time and half-life time for overlooked synchronous metastases in colorectal carcinoma.

    Science.gov (United States)

    Ito, Katsuki; Hibi, Kenji; Ando, Hideyuki; Hidemura, Kazuhiko; Yamazaki, Taiji; Akiyama, Seiji; Nakao, Akimasa

    2002-02-01

    Measurement of carcinoembryonic antigen (CEA) has been widely applied to detect recurrence, especially of colorectal carcinoma. The validity however, is still controversial. We investigated serial changes in CEA values to calculate whether the CEA doubling time and half-life time could predict metastatic progression or prognosis in colorectal carcinoma. Pre- and post-operative serial serum CEA contents were determined in 22 cases of colorectal cancer with or without metastasis. CEA values were determined by enzyme immunoassay (EIA). Patients were assigned depending upon survival time (within vs. more than 18 months after primary resection) for assessment of CEA doubling time. From the gradient of the semi-logarithmic CEA graph, the preoperative doubling time was calculated and the postoperative half-life time was estimated according to the diagnosis of metastases within 2 years after primary resection [metastasis (+) or (-)]. In spite of the effect of curative re-operation of metastatic lesions or of postoperative adjuvant chemotherapy, the CEA doubling time of the groups showed a relation with prognosis (p = 0.045, Student's t-test) when the patients were divided into >18 and time. The CEA half-life time of the groups without overlooked metastases was statistically longer than those with (mean +/- SD 8.01 +/- 2.07 and 4.33 +/- 1.11, respectively, p Clearance (k) showed a significant difference between the groups (p time appeared to be a less independent prognostic factor, whereas prolongation of the CEA half-life time might potentially suggest the existence of overlooked synchronous metastases from colorectal carcinoma.

  14. Cleansing and dismantling of CEA-Saclay nuclear licensed facilities

    International Nuclear Information System (INIS)

    Jeanjacques, Michel; Delaire, Isabelle; Glevarec, Rebecca; Mandard, Lionel; Martin, Jean-Louis; Serrano, Roger

    2013-01-01

    This summary presents the cleansing and dismantling operations currently realized on the CEA center of Saclay (CEA-Saclay). It was initiated at the beginning of the 2000 years a cleansing and dismantling program of the old Nuclear Licensed Facilities (NLF). Currently this program relates the dismantling operations to the Hot Laboratories (Laboratoires de Haute Activite: LHA) and the old workshops of the Liquid Waste Treatment Plant (Station des Effluents Liquides: STEL), the dismantling preparation of Ulysse reactor and the dismantling studies to the Solid Waste Management Plant (SWMP; Zone de Gestion des Dechets Solides) and the Osiris reactor. (authors)

  15. Recapitulative list of the C.E.A. reports published by the French Atomic Energy Commission (n.757-1062, december 1957-december 1958) supplement to C.E.A. reports n. 593 and 756

    International Nuclear Information System (INIS)

    Schmiterlow, C.G.; Cohen, Y.

    1958-01-01

    Recapitulative list of the C.E.A. reports published by the French Atomic Energy Commission. (number 757-1062, december 1957 - december 1958). Supplement to C.E.A. reports number 593 and 756. (author) [fr

  16. CEA in activated macrophages. New diagnostic possibilities for tumor markers in early colorectal cancer.

    Science.gov (United States)

    Japink, Dennis; Leers, Mathie P G; Sosef, Meindert N; Nap, Marius

    2009-08-01

    Serum tumor markers show low sensitivity, making them unsuitable for early detection of cancer. Activated macrophages (AM) from peripheral blood can accumulate tumor marker substances and facilitate early detection in prostate cancer. Here it was investigated whether carcinoembryonic antigen (CEA)-containing macrophages (CEACM) can be used to detect colorectal cancer (CRC) at earlier stages than can serum CEA. Peripheral blood was collected from patients with CRC (n=48), inflammatory colorectal disease (n=5) and from healthy controls (n=18). After separating and labeling AM with CD14-APC/CD16-FITC, AM were intracellularly labeled with anti-CEA antibody and flow cytometrically analyzed. Serum CEA and C-reactive protein (CRP) were measured. The fraction-size of CEACM discriminated between controls and CRC patients, irrespective of AJCC stage (AJCC stage I-IV, pCEA values were significantly elevated in AJCC stage II, III and IV (p=0.02, 0.006 and <0.0001, respectively). Combining CEACM with CRP levels separated CRC from inflammatory colorectal disease. CEACM combined with CRP appears to have diagnostic potential in early CRC.

  17. Clinical significance of determination of serum VEGF and CEA levels in patients with colorectal cancer

    International Nuclear Information System (INIS)

    Du Xiaohui; Song Shaobai; Zheng Wei

    2007-01-01

    Objective: To study the applicability of combined determination of serum VEGF and CEA levels in the diagnosis of colorectal cancer as well as the relationship between VEGF level and stage of the disease. Methods: Serum VEGF (with ELISA) and CEA (with RIA) levels serum were detected in 28 patients with colorectal cancer of various stages and 29 controls. Results: The diagnostic positive rate was 53.6% (15/28), 39.3% (11/28), 71.4% (20/28) with CEA, VEGF and combined test for colorectal cancer, respectively. The serum VEGF levels in patients with advance colorectal cancer were significantly higher than those in patients with earlier stages diseases and controls, VEGF levels were positively correlated with CEA levels (P<0.05). Conclusion: Combined detection of the levels of serum VEGF and CEA could improve significantly the diagnostic positive rate in patients with colorectal cancer. (authors)

  18. 2011 reporting of the risk handling at CEA

    International Nuclear Information System (INIS)

    Anon.

    2012-01-01

    In 2011 CEA reported 100 events to the Authority for Nuclear Safety (ASN). 93 were graded 0 on the INES scale and 7 were graded 1. None of them had a significant impact on the staff health and the environment. 25% of these events concerned delays in the controls of safety equipment. In 2011 CEA had to manage several situations that led to a response of its crisis center: 1) the explosion of an oven belonging to the Socodei-Centraco company situated near the Marcoule Center, 2) the discovery of about 500 grenades from the first world war during digging out works in the Grenoble Center, 3) flooding due to heavy rains in the Cadarache Center, and 4) an intrusion attempt at the Cadarache Center. (A.C.)

  19. CA72-4 e CEA no soro e no lavado peritonial de doentes com câncer gástrico CA72-4 and CEA in serum and peritoneal washing in gastric cancer

    Directory of Open Access Journals (Sweden)

    Sandra MANDORWSKI

    2002-03-01

    Full Text Available Racional - O tratamento e o prognóstico dos pacientes com câncer gástrico dependem, principalmente, do estádio clínico. Os marcadores tumorais séricos e do lavado peritonial podem auxiliar a avaliar o risco de recurrência da doença. Casuística e Métodos - Quarenta pacientes com câncer gástrico (11 estádio I ou II e 29 estádio III ou IV e 24 com doença benigna foram estudados prospectivamente. Todos os doentes foram submetidos a laparotomia. O sangue e o lavado peritonial foram colhidos durante o ato cirúrgico, antes da retirada do tumor, para determinação dos marcadores CEA e CA72-4. Resultados - Vinte e cinco por cento e 47,5% dos pacientes com câncer gástrico apresentam elevação dos níveis séricos de CEA e CA72-4. Através das curvas ROC definiram-se os valores de corte dos marcadores no lavado peritonial. Através destas curvas, observaram-se que 60% e 57,5% apresentavam CEA e CA72-4 elevado, respectivamente no grupo com câncer gástrico. Os valores de CEA e CA72-4 foram maiores nos pacientes estádios III e IV. No lavado peritonial, os níveis de CEA foram maiores nos doentes com tumores T3-4. Os valores de CA72-4 no lavado peritonial diferenciaram o grupo controle do grupo com câncer gástrico. Conclusão - O CA72-4 foi o marcador sérico mais sensível no diagnóstico de câncer gástrico. Entretanto, no lavado peritonial, o marcador mais sensível foi o CEA. Os valores de CEA foram superiores nos tumores que ultrapassam a serosa e inferiores nos tumores que se restringem a mucosa e muscular.Background - The treatment and the prognosis of gastric cancer patients depends mainly on clinical stage. Serum and peritoneal tumoral markers levels can be helpful to evaluate individual risk for recurrence. Aims - To evaluate the sensibility of the tumoral markers in the serum and in the peritoneal washing on diagnosis of gastric cancer. Patients and Methods - Forty patients with adenocarcinoma of the stomach (11 stage I or

  20. Hookah smoking and cancer: carcinoembryonic antigen (CEA levels in exclusive/ever hookah smokers

    Directory of Open Access Journals (Sweden)

    Chaouachi Kamal

    2008-05-01

    Full Text Available Abstract Background We have recently published some work on CEA levels in hookah (also called narghile, shisha elsewhere and cigarette smokers. Hookah smokers had higher levels of CEA than non-smokers although mean levels were low compared to cigarette smokers. However some of them were also users of other tobacco products (cigarettes, bidis, etc.. Objectives To find serum CEA levels in ever/exclusive hookah smokers, i.e. those who smoked only hookah (no cigarettes, bidis, etc., prepared between 1 and 4 times a day with a quantity of up to 120 g of a tobacco-molasses mixture each (i.e. the tobacco weight equivalent of up to 60 cigarettes of 1 g each and consumed in 1 to 8 sessions. Methods Enhanced chemiluminescent immunometric technique was applied to measure CEA levels in serum samples from 59 exclusive male smokers with age ranging from 20–80 years (mean = 58.8 ± 14.7 years and 8–65 years of smoking (mean = 37.7 ± 16.8. 36 non-smokers served as controls. Subjects were divided into 3 groups according to the number of preparations; the number of sessions and the total daily smoking time: Light (1; 1; ≤ 20 minutes; Medium (1–3; 1–3; >20 min to ≤ 2 hrs and Heavy smokers (2–4; 3–8; >2 hrs to ≤ 6 hrs. Because of the nature of distribution of CEA levels among our individuals, Wilcoxon's rank sum two-sample test was applied to compare the variables. Results The overall CEA levels in exclusive hookah smokers (mean: 3.58 ± 2.61 ng/ml; n = 59 were not significantly different (p ≤ 0.0937 from the levels in non-smokers (2.35 ± 0.71 ng/ml. Mean levels in light, medium and heavy smokers were: 1.06 ± 0.492 ng/ml (n = 5; 2.52 ± 1.15 ng/ml (n = 28 and 5.11 ± 3.08 ng/ml (n = 26 respectively. The levels in medium smokers and non-smokers were also not significantly different (p ≤ 0.9138. In heavy smokers, the CEA levels were significantly higher than in non-smokers (p ≤ 0.0001567. Conclusion Overall CEA levels in exclusive hookah

  1. Iodine-131 labeled anti-CEA polyclonal antibody detection of gastrointestinal cancer

    International Nuclear Information System (INIS)

    Nabi, H.A.; Hinkle, G.H.; Olsen, J.O.; Haagensen, D.A.; Thurston, M.O.; Mojzisik, C.; Houchens, D.; Martin, E.W. Jr.

    1984-01-01

    To localize gastrointestinal tumor, 31 patients were injected with 1.7-2.1 mCi I-131 anti-CEA baboon polyclonal antibody. Whole body imaging at 48, 72, and occasionally 96 hrs was performed with a Signa Camera (Technicare) peaked at 364 keV with 20% window. Additional spot views were usually obtained. No subtraction methods were used. All patients had surgical and pathological confirmation of the nuclear medicine studies. Labeled antibody images were positive in 15 (8 recurrent or metastatic colorectal, 2 gastric, 1 pancreatic, 1 primary colon, and 1 breast metastatic to chest wall). In 1, antibody images were positive for metastatic deposits in para-aortic lymph nodes, but negative for primary rectal tumor. True negative images were observed in 6; false negative images in 9 (4 liver metastases, 2 rectal, 1 pancreatic, 1 mesenteric lymph node metastasis, 1 bone metastasis). In all cases, no correlation existed between preoperative CEA serum levels and imaging. I-131 labeled anti-CEA polyclonal antibody imaging proved highly efficient in detecting gastric cancer (2/2) and moderately efficient in detecting recurrent colorectal cancer (8/15). On the other hand, the I-131 labeled polyclonal anti-CEA antibody imaging was of limited value in detecting colon cancer (1/9), pancreatic cancer (1/4) and metastatic liver disease

  2. CEA: risk management assessment 2011

    International Nuclear Information System (INIS)

    Bigot, Bernard; Bonnevie, Edwige; Maillot, Bernard

    2012-01-01

    This report proposes a qualitative and quantitative overview of CEA activities in the field of risk management during 2011. These activities concerned the impact on the environment, the safety of installations, the management of professional risks (safety and health at work), the radiological protection of workers, the transports of hazardous materials, waste management, protection of sites, installations and heritage, the management of emergency situations, the management of law risks, controls and audits

  3. CEA A BIOCHEMICAL MARKER FOR DIAGNOSIS AND PROGNOSIS OF GASTROINTESTINAL CANCER

    OpenAIRE

    Prathibha; Vishnu Datt

    2016-01-01

    Serum tumor markers (TM) are widely used for diagnosis and monitoring of treatment of cancer. Carcinoembryonic Antigen (CEA) is one of the most widely investigated tumor markers in gastrointestinal (GI) cancers. Estimation of circulating tumor markers is a non- invasive quantitative method. Serum levels of CEA were studied for diagnosis and prognosis of gastrointestinal malignancies. 140 subjects were undertaken out of which 35 normal and remaining 105 were GI cancer patients. Ser...

  4. Apport de la simulation numérique à la compréhension des mécanismes d'interaction de cavités dans le cadre de la modélisation de l'endommagement ductile sous sollicitation dynamique

    Science.gov (United States)

    Roy, G.; Buy, F.; Llorca, F.

    2002-12-01

    L'étude présentée s'inscrit dans le cadre d'une démarche menant à la construction d'un modèle analytique ou semi analytique de comportement élasto-visco-plastique endommageable, applicable aux chargements rencontrés en configuration d'impact violent et générant de l'écaillage ductile. La prise en compte des effets de compressibilité et de micro inertie est essentielle pour modéliser la phase de croissance. Des simulations numériques globales de la structure et locales à l'échelle des hétérogénéités permettent d'évaluer les niveaux de sollicitations dans les zones susceptibles de s'endommager, dévaluer des critères analytiques de germination de l'endommagement et de comprendre les mécanismes d'interaction entre les défauts. Les effets micro inertiels et de compressibilité sont ainsi mis en évidence dans les phases de germination et de coalescence des micro défauts. II s'agit ici d'une illustration non exhaustive de travaux engagés au CEA Valduc sur le tantale, dans le cadre d'une thèse [10]. Un programme matériaux en partenariat CEA-CNRS sur la modélisation multi échelles du comportement de structures a également été initié dans ce contexte.

  5. CEA and CA 19-9 are still valuable markers for the prognosis of colorectal and gastric cancer patients.

    Science.gov (United States)

    Sisik, Abdullah; Kaya, Mustafa; Bas, Gurhan; Basak, Fatih; Alimoglu, Orhan

    2013-01-01

    The purpose of this study was to assess the predictive effect of preoperative CEA and CA 19-9 levels on the prognosis of colorectal and gastric cancer patients. CEA and CA 19-9 were evaluated preoperatively in patients undergoing surgery for colorectal cancer (n=116) and gastric cancer (n=49). Patients with CEA levels CEA Group 1, 5-30 ng/mL as CEA Group 2 and >30 ng/ mL were classified as CEA Group 3. Similarly the patients with a CA 19-9 level 100 U/mL as Group and 3. TNM stages and histologic grades were noted according to histopathological reports. Patients with a TNM grade 0 or 1 were classified as Group A, TNM grade 2 patients constituted Group B and TNM grade 3 and 4 patients constituted Group C. Demographic characteristics, tumor locations and blood types of the patients were all recorded and these data were compared with the preoperative CEA and CA19-9 values. A significant correlation between CA 19-9 levels (>100 U/mL) and TNM stage (in advanced stages) was determined. We also determined a significant correlation between TNM stages and positive vlaues for both CEA and CA 19-9 in colorectal and gastric cancer patients. In comparison between CEA and CA 19-9 levels and age, gender, tumor location, ABO blood group, and tumor histologic grade, no significant correlation was found. Positive levels of both CEA and CA 19-9 can be considered to indicate an advanced stage in colorectal and gastric cancer patients.

  6. Uropathogenic E. coli Exploit CEA to Promote Colonization of the Urogenital Tract Mucosa

    Science.gov (United States)

    Muenzner, Petra; Kengmo Tchoupa, Arnaud; Klauser, Benedikt; Brunner, Thomas; Putze, Johannes; Dobrindt, Ulrich; Hauck, Christof R.

    2016-01-01

    Attachment to the host mucosa is a key step in bacterial pathogenesis. On the apical surface of epithelial cells, members of the human carcinoembryonic antigen (CEA) family are abundant glycoproteins involved in cell-cell adhesion and modulation of cell signaling. Interestingly, several gram-negative bacterial pathogens target these receptors by specialized adhesins. The prototype of a CEACAM-binding pathogen, Neisseria gonorrhoeae, utilizes colony opacity associated (Opa) proteins to engage CEA, as well as the CEA-related cell adhesion molecules CEACAM1 and CEACAM6 on human epithelial cells. By heterologous expression of neisserial Opa proteins in non-pathogenic E. coli we find that the Opa protein-CEA interaction is sufficient to alter gene expression, to increase integrin activity and to promote matrix adhesion of infected cervical carcinoma cells and immortalized vaginal epithelial cells in vitro. These CEA-triggered events translate in suppression of exfoliation and improved colonization of the urogenital tract by Opa protein-expressing E. coli in CEA-transgenic compared to wildtype mice. Interestingly, uropathogenic E. coli expressing an unrelated CEACAM-binding protein of the Afa/Dr adhesin family recapitulate the in vitro and in vivo phenotype. In contrast, an isogenic strain lacking the CEACAM-binding adhesin shows reduced colonization and does not suppress epithelial exfoliation. These results demonstrate that engagement of human CEACAMs by distinct bacterial adhesins is sufficient to blunt exfoliation and to promote host infection. Our findings provide novel insight into mucosal colonization by a common UPEC pathotype and help to explain why human CEACAMs are a preferred epithelial target structure for diverse gram-negative bacteria to establish a foothold on the human mucosa. PMID:27171273

  7. Clinical significance of determination of serum SA, CEA and CRP levels in patients with colo-rectal cancer

    International Nuclear Information System (INIS)

    Cai Jie; Hu Junyan; Sun Shuming; Cheng Benkun

    2007-01-01

    Objective: To investigate the clinical usefulness of determination of serum SA, CEA and CRP levels in patients with colorectal cancer. Methods: Serum SA (with colorimetry), CEA (with CLIA) and CRP (with ILIA) levels were measured in 120 patients with colo-rectal cancer. Results: (1) Serum SA, CEA and CRP levels increased significantly as the disease stage advanced from Duke A through Duke D. (2) As the malignancy of the growth advanced from well-differentiated to anaplastic, the serum SA and CRP levels increased significantly while the reverse was true for serum CEA levels. (3) In 68 post-operative patients followed 1-5 years, the serum levels of SA, CEA and CRP were significantly higher in the patients with recurrence (n=29) than those in patients without recurrence (n=39) (P<0.01). Conclusion: Serum SA CEA and CRP levels were closely related to the disease process in patients with colo-rectal cancer. (authors)

  8. Annual report of the Association EURATOM/Cea

    International Nuclear Information System (INIS)

    Magaud, Ph.; Le Vagueres, F.

    2002-01-01

    This annual report presents research activities, which have been performed in 2002 by the French EURATOM-Cea association in the frame of the European technology program. The first section describes EFDA (European fusion development agreement) activities and related developments carried out by the association. The second one is dedicated to the underlying technology program and finally the third one presents the inertial confinement fusion activities. In each section the tasks are sorted out according to the EFDA main fields: physics (heating and current drive, remote participation, diagnostics), vessel/in-vessel (vessel/blanket, plasma facing components, remote handling), magnet, tritium breeding and materials (water cooled lithium lead blanket, helium cooled pebble bed blanket, helium cooled lithium lead blanket, reduced activation ferritic martensitic steels, advanced materials, neutron source, fuel cycle), safety and environment, system studies (power plant conceptual studies, socio-economic studies) and JET technology activities. The EURATOM-Cea association is involved in all these studies

  9. Annual report of the Association EURATOM/Cea

    Energy Technology Data Exchange (ETDEWEB)

    Magaud, Ph; Le Vagueres, F

    2002-07-01

    This annual report presents research activities, which have been performed in 2002 by the French EURATOM-Cea association in the frame of the European technology program. The first section describes EFDA (European fusion development agreement) activities and related developments carried out by the association. The second one is dedicated to the underlying technology program and finally the third one presents the inertial confinement fusion activities. In each section the tasks are sorted out according to the EFDA main fields: physics (heating and current drive, remote participation, diagnostics), vessel/in-vessel (vessel/blanket, plasma facing components, remote handling), magnet, tritium breeding and materials (water cooled lithium lead blanket, helium cooled pebble bed blanket, helium cooled lithium lead blanket, reduced activation ferritic martensitic steels, advanced materials, neutron source, fuel cycle), safety and environment, system studies (power plant conceptual studies, socio-economic studies) and JET technology activities. The EURATOM-Cea association is involved in all these studies.

  10. Radioiodination of monoclonal antibody intact anti-CEA

    International Nuclear Information System (INIS)

    Okada, H.; Souza, I.T.T.; Silva, C.P.G.

    1990-11-01

    The purpose of this study is to examine a convenient system that can be used to iodinate monoclonal antibodies which is rapid, simple, efficient and reproducible, and which can be accomplished in radiopharmaceutical laboratories. It is important to remember that antibodies are sensitive biochemicals, subject to losses of the activity that is essential to their mode of action, namely the ability to bind specific antigen. The advent of solid phase iodination agents has greatly expanded the range of gentle iodination techniques available for iodinating sensitive biological materials. The agent most widely used is the Iodogen (1,3,4,6 tetrachloro-3a-6a diphenylglycoluril) method. Anti-CEA 4C sub(11) IgG sub(2a,k) (prepared in the Ludwig Institute-Sao Paulo-Brazil ) is used as model to evaluate the Iodogen methodology. The miniature chromatographic system, also rapid, accurate, simple, efficient was elaborated to determine the labelling efficiency incorporation of iodine into immunoglobulin, and the radiochemical purity of sup(131)I-anti-CEA. (author)

  11. Summary 1998. Releases control and environment monitoring for the CEA Centers

    International Nuclear Information System (INIS)

    1998-01-01

    In the framework of its environmental policy, the CEA aims at reduce as weak as possible, in regards to the technological and economic needs, its activities impacts on the people and the environment. This paper contributes to the public information on the radioactive gaseous and liquid releases during the year 1998. It presents data on the releases and the radioactivity levels around the CEA sites and gathers the associated regulation and monitoring methods. (A.L.B.)

  12. Comparison of Ablation Predictions for Carbonaceous Materials Using CEA and JANAF-Based Species Thermodynamics

    Science.gov (United States)

    Milos, Frank S.

    2011-01-01

    In most previous work at NASA Ames Research Center, ablation predictions for carbonaceous materials were obtained using a species thermodynamics database developed by Aerotherm Corporation. This database is derived mostly from the JANAF thermochemical tables. However, the CEA thermodynamics database, also used by NASA, is considered more up to date. In this work, the FIAT code was modified to use CEA-based curve fits for species thermodynamics, then analyses using both the JANAF and CEA thermodynamics were performed for carbon and carbon phenolic materials over a range of test conditions. The ablation predictions are comparable at lower heat fluxes where the dominant mechanism is carbon oxidation. However, the predictions begin to diverge in the sublimation regime, with the CEA model predicting lower recession. The disagreement is more significant for carbon phenolic than for carbon, and this difference is attributed to hydrocarbon species that may contribute to the ablation rate.

  13. Correlation between Changes in Serum Level of CEA and CYFRA 21-1 and Objective Response of Chemotherapy

    Directory of Open Access Journals (Sweden)

    Xinlin MU

    2009-09-01

    Full Text Available Background and objective Serum levels of tumor markers are associated with tumor metabolism or apoptosis, changes of which after chemotherapy may reflect tumor response to treatment. The aim of this study was to assess the predictive role of changes in serum levels of carcinoembryonic antigen (CEA and cytokeratin 19 fragment (CYFRA 21-1 during chemotherapy in patients with advanced non-small cell lung cancer. Methods Changes in serum levels of CEA and CYFRA 21-1 were investigated retrospectively after one cycle of chemotherapy in 42 patients with advanced NSCLC. Correlations between the changes and radiological objective response were analyzed. Results After two cycles of chemotherapy, radiological objective response rate was 28.6%. At baseline, gender, age, clinical stage, serum levels of CEA and CYFRA 21-1 were not different between patients with objective response (OR and no response (NR. After one cycle of chemotherapy, compared to baseline level, declines in serum levels of CEA and CYFRA 21-1 were observed in patients with OR, but have no statistical significance. In contrast, reduction of CEA and CYFRA 21-1 over baseline after one cycle of chemotherapy showed statistically significant difference between OR and NR. When reduction percentages of CEA and CYFRA 21-1 were used to predict objective response of chemotherapy, the area under the ROC curve (AUC was 0.875 for CEA and 0.919 for CYFRA 21-1. According to the ROC curve, a 22% reduction of CEA yielded a sensitivity of 58.3% and a specificity of 97%, 51% reduction of CYFRA 21-1 with a sensitivity of 83.3% and a specificity of 93.3%. When above reduction percentages were used as cutoffs for prediction of radiological objective response, combination of the CEA and CYFRA 21-1 yielded a sensitivity of 91.7% and a specificity of 86.7%. Conclusion Reduction percentages of CEA and CYFRA 21-1 during chemotherapy could be used to evaluate chemotherapy efficacy in patients with advanced NSCLC. The

  14. Expression Study of LeGAPDH, LeACO1, LeACS1A, and LeACS2 in Tomato Fruit (Solanum lycopersicum

    Directory of Open Access Journals (Sweden)

    Pijar Riza Anugerah

    2015-10-01

    Full Text Available Tomato is a climacteric fruit, which is characterized by ripening-related increase of respiration and elevated ethylene synthesis. Ethylene is the key hormone in ripening process of climacteric fruits. The objective of this research is to study the expression of three ethylene synthesis genes: LeACO1, LeACS1A, LeACS2, and a housekeeping gene LeGAPDH in ripening tomato fruit. Specific primers have been designed to amplify complementary DNA fragment of LeGAPDH (143 bp, LeACO1 (240 bp, LeACS1A (169 bp, and LeACS2 (148 bp using polymerase chain reaction. Nucleotide BLAST results of the complementary DNA fragments show high similarity with LeGAPDH (NM_001247874.1, LeACO1 (NM_001247095.1, LeACS1A (NM_001246993.1, LeACS2 (NM_001247249.1, respectively. Expression study showed that LeACO1, LeACS1A, LeACS2, and LeGAPDH genes were expressed in ripening tomato fruit. Isolation methods, reference sequences, and primers used in this study can be used in future experiments to study expression of genes responsible for ethylene synthesis using quantitative polymerase chain reaction and to design better strategy for controlling fruit ripening in agroindustry.

  15. Thermal-hydraulic investigations on the CEA-ENEA DEMO relevant helium cooled poloidal blanket

    International Nuclear Information System (INIS)

    Dell'Orco, G.; Polazzi, G.; Vallette, F.; Proust, E.; Eid, M.

    1994-01-01

    The CEA-ENEA design of an Helium Cooled Solid Breeder Blanket (HCSBB) for the DEMO reactor, with a breeder in tube (BIT) poloidal arrangement, is based on the use of lithium ceramic pellets, the ENEA γ-LiAlO 2 or the CEA Li 2 ZrO 3 . Due to the geometry of the DEMO reactor plasma chamber, these breeder bundles are adapted to the Vacuum Vessel with a strong poloidal curvature. This curvature influences the thermal-hydraulic behaviour of the coolant flowing inside the bundle. The paper presents the CEA-ENEA first results of the experimental and theoretical programme, aiming at optimizing the breeder module thermal hydraulic design. (author) 6 refs.; 7 figs.; 1 tab

  16. Mechanical modelling of PCI with FRAGEMA and CEA finite element codes

    International Nuclear Information System (INIS)

    Joseph, J.; Bernard, Ph.; Atabek, R.; Chantant, M.

    1983-01-01

    In the framework of their common program, CEA and FRAGEMA have undertaken the mechanical modelization of PCI. In the first step two different codes, TITUS and VERDON, have been tested by FRAGEMA and CEA respectively. Whereas the two codes use a finite element method to describe the thermomechanical behaviour of a fuel element, input models are not the same for the two codes: to take into account the presence of cracks in UO 2 , an axisymmetric two dimensional mesh pattern and the Druecker-Prager criterion are used in VERDON and a 3D equivalent method in TITUS. Two rods have been studied with these two methods: PRISCA 04bis and PRISCA 104 which were ramped in SILOE. The results show that the stresses and strains are the same with the two codes. These methods are further applied to the complete series of the common ramp test rods program of FRAGEMA and CEA. (author)

  17. CEA: assessment of risk management 2011

    International Nuclear Information System (INIS)

    2012-06-01

    This report proposes an overview of CEA activities in the field of risk management in different areas: impact on the environment, installation safety, management of occupational risks (occupational health and safety), radiological protection of workers, transportation of hazardous materials, waste management, protection of sites, installations and heritage, management of emergency situations, management of law risks, controls and audits. It finally presents the risk management department

  18. Use of radioimmunodetection of carcinoembryonic antigen (CEA) and ferritin in diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Zamyatin, S.S.; Zakharychev, V.D.

    1989-01-01

    To study the diagnostic value of radioimmunoassay (RIA) of carcinoembryonic antigen (CEA) and ferritin the level of this markers under lung cancer depending on the tumor localization and the process stage is determined. It is shown that determination of CEA and ferritin level in a number of patients with the peripheral lung cancer allows on the confirm the diagnosis. In case of the central cancer an increase of CEA level testifies to the tumor germination into the adjacent organs and lung tissue and allows one to determine the stage and operability of the disease. 10 refs.; 3 tabs

  19. Use of a combination of CEA and tumor budding to identify high-risk patients with stage II colon cancer.

    Science.gov (United States)

    Du, Changzheng; Xue, Weicheng; Dou, Fangyuan; Peng, Yifan; Yao, Yunfeng; Zhao, Jun; Gu, Jin

    2017-07-24

    High-risk patients with stage II colon cancer may benefit from adjuvant chemotherapy, but identifying this patient population can be difficult. We assessed the prognosis value for predicting tumor progression in patients with stage II colon cancer, of a panel of 2 biomarkers for colon cancer: tumor budding and preoperative carcinoembryonic antigen (CEA). Consecutive patients (N = 134) with stage II colon cancer who underwent curative surgery from 2000 to 2007 were included. Multivariate analysis was used to evaluate the association of CEA and tumor budding grade with 5-year disease-free survival (DFS). The prognostic accuracy of CEA, tumor budding grade and the combination of both (CEA-budding panel) was determined. The study found that both CEA and tumor budding grade were associated with 5-year DFS. The prognostic accuracy for disease progression was higher for the CEA-budding panel (82.1%) than either CEA (70.9%) or tumor budding grade (72.4%) alone. The findings indicate that the combination of CEA levels and tumor budding grade has greater prognostic value for identifying patients with stage II colon cancer who are at high-risk for disease progression, than either marker alone.

  20. Le laboratoire, le temple et le marché

    International Development Research Centre (IDRC) Digital Library (Canada)

    De manière générale, les auteurs insistent sur le fait que c'est leur foi qui leur a .... nettement que dans de nombreux cercles, le besoin était vivement ressenti de ... Le Dr Kapur présente tout d'abord une brève discussion sur sa vision du ...... pour les soins aux enfants orphelins et aux pauvres et pour la renaissance des ...

  1. Evaluation of detection methodology for carcinoembryonic antigen and application of CEA in diagnosis of gastric cancer

    International Nuclear Information System (INIS)

    Wang Enlan; Li Tao

    2005-01-01

    To compare the specificity and sensitivity of different methods in detection of CEA, and to investigate the application of CEA detection in diagnosis of gastric cancer, CEA in serum of 36 patients with gastric cancer and 20 negtive reference serum was detected by ELISA, TR- FIA, RIA and CLIA. The results showed that the specificity of these 4 methods was all 100% and the sensitivity of ELISA was the lowest (19.4%) while CLIA was the highest (44.4%). Therefore, the sensitivity of ELISA should be raised and CEA, besides used as an observation index for curative effects in a part of gastric cancer patients, can not be used in diagnosis of gastric cancer. (authors)

  2. Changes in the legal status of the Commissariat a l'energie atomique (Cea)

    International Nuclear Information System (INIS)

    Grammatico-Vidal, L.

    2009-01-01

    The Cea a public research institution was re-classified among the energy research establishments (11 december 2008). The Cea, as the result of exceptional circumstances and complex activities, is today entering into a new era and must confront many national and supranational challenges. It is preparing, in effect, for a future nuclear industry (safer, less polluting, non-proliferating and more economical) and is conducting research into other energy solutions within the framework of sustainable development and limited greenhouse gas effects (hydrogen technology, fusion, alternative energy technologies). It also has another goal, to make technological research available to industry, not only by developing micro and nano-technologies or even to contribute technology for the benefit of scientific knowledge of living creatures, matter, climate and the environment. The new classification of the Cea as a research establishment in the field of energy, a heading which includes three other entities (A.N.D.R.A., A.D.E.M.E. and I.F.P.), raises questions about its specialization and diversification. However, no substantive change was made to the drafting of the legislative provisions so it is possible to imagine that the Cea takes initiatives in other fields, at the instigation or with the approval of the government, a matter which is facilitated by its classification in the E.P.I.C. category (public establishment at industrial and commercial character). The Cea also represents France in international organisations in the nuclear sector, such as the OECD Nuclear energy agency (Nea), the International atomic energy agency (IAEA) and the European communities. It also participates in intergovernmental negotiations in the nuclear field and ensures any follow-up required with regard to any resulting agreements. today, the Cea plays a major role in the implementation of French nuclear policy with the aim of making available to countries wishing to develop nuclear energy, a framework

  3. Multiple myeloma presenting as CEA-producing rectal cancer.

    Science.gov (United States)

    Talamo, Giampaolo; Barochia, Amitkumar; Zangari, Maurizio; Loughran, Thomas P

    2010-03-31

    We report the case of a 57-year-old patient with multiple myeloma, characterized by extramedullary involvement of the rectum at presentation. Malignant plasma cells were found to produce carcinoembryonic antigen (CEA), a tumor antigen more commonly associated with rectal adenocarcinomas.

  4. Environmental monitoring of the Cea Valduc centre

    International Nuclear Information System (INIS)

    Guetat, Ph.; Jaskula, L.

    2010-01-01

    This paper describes the main features of the environmental control in the vicinity of the CEA Valduc centre, explains the site specific characteristics, the surveillance policy, and some historical elements about tritium atmospheric release. Some levels of activities are given, corresponding to an exposure level below 0.02% of natural irradiation. (author)

  5. Report transparency and nuclear safety 2007 CEA Saclay; Rapport transparence et securite nucleaire 2007 CEA Saclay

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This report presents the activities of the CEA Center of Saclay for the year 2007. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially two public consultation on release authorizations and the Neurospin installations, the dismantling of the 49 nuclear installation, the shutdown of the learning reactor ULYSSE are detailed. (A.L.B.)

  6. Lele des chefs traditionnels au Ghana : un modèle inspirant ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    8 févr. 2011 ... Avec ses partenaires du Sud, avec aussi le soutien du Centre de recherches pour le développement international ( CRDI ), organisme canadien, Ray a étudié lele des chefs traditionnels au Ghana dans la lutte contre le VIH et le sida. Les collectivités politiques antérieures au colonialisme sont une ...

  7. Diabody construct of ior-CEA1. Pre-clinical studies for therapeutic application

    International Nuclear Information System (INIS)

    Pimentel, G.; Ravelo, R.; Miranda, M.; Sanchez, I.; Perez, L.; Ayala, M.; Gavilondo, J.

    2007-01-01

    Full text: The classic radioimmunotherapy is based on transporting to the tumor, the necessary activity of a therapeutic isotope using a monoclonal antibody (MAb) against tumor associated antigen, which constitutes an ideal vehicle given its inherent specificity. In this sense, the immunoglobulin (Ig) has some severe practical limitations due to its unhappy pharmacokinetics, relatively high molecular weight (150 kDa) and slower clearance. Likewise the Ig molecule presents a poor diffusion through the tumor mass and a relative high immunogenicity. The solution to these problems has been offered by genetic engineering, methods where the multivalent recombinant fragments have become the paradigm of design of constructed molecules. They are able to retain the specificity of the parental antibody and affinity, with reduced immunogenicity and improved pharmacokinetics. The monoclonal antibody ior-CEA1 has been employed for the diagnosis of primary tumors, recurrences and metastatic disease, and has also been used extensively in the daily clinical practice as well. Inserted in this rebirth of the antibodies, this report explores the use of a new smaller molecular weight multivalent analogue of the parent ior-CEA1 antibody to be used for the diagnosis and therapy of CEA-expressing malignant tumors such as colorectal, lung, ovary among others. The dimeric scFv-ior- CEA1 construct was produced in the Centre for Genetic Engineering and Biotechnology and displayed to bind CEA epitope with a similar binding affinity to that of the murine IgG. Method: Labelling was achieved using Chloramine T, with a molar ration of Chloramine T:Tyrosine of 2.5. For the comparison of the immunoreactivity of labeled and unlabelled diabodies, was plotted the specific union vs the antibody concentration for both molecules and adjusted to a straight line. The immunoreactivity was also assayed using size-exclusion FPLC to evaluate their antigen-binding capacities after radiolabelling. Seventy

  8. The value of KRAS mutation testing with CEA for the diagnosis of pancreatic mucinous cysts

    Science.gov (United States)

    Kadayifci, Abdurrahman; Al-Haddad, Mohammad; Atar, Mustafa; Dewitt, John M.; Forcione, David G.; Sherman, Stuart; Casey, Brenna W.; Fernandez-del Castillo, Carlos; Schmidt, C. Max; Pitman, Martha B.; Brugge, William R.

    2016-01-01

    Background and aims: Pancreatic cyst fluid (PCF) CEA has been shown to be the most accurate preoperative test for detection of cystic mucinous neoplasms (CMNs). This study aimed to assess the added value of PCF KRAS mutational analysis to CEA for diagnosis of CMNs. Patients and methods: This is a retrospective study of prospectively collected endoscopic ultrasonography (EUS) fine-needle aspiration (FNA) data. KRAS mutation was determined by direct sequencing or equivalent methods. Cysts were classified histologically (surgical cohort) or by clinical (EUS or FNA) findings (clinical cohort). Performance characteristics of KRAS, CEA and their combination for detection of a cystic mucinous neoplasm (CMN) and malignancy were calculated. Results: The study cohort consisted of 943 patients: 147 in the surgical cohort and 796 in the clinical cohort. Overall, KRAS and CEA each had high specificity (100 % and 93.2 %), but low sensitivity (48.3 % and 56.3 %) for the diagnosis of a CMN. The positivity of KRAS or CEA increased the diagnostic accuracy (80.8 %) and AUC (0.84) significantly compared to KRAS (65.3 % and 0.74) or CEA (65.8 % and 0.74) alone, but only in the clinical cohort (P < 0.0001 for both). KRAS mutation was significantly more frequent in malignant CMNs compared to histologically confirmed non-malignant CMNs (73 % vs. 37 %, P = 0.001). The negative predictive value of KRAS mutation was 77.6 % in differentiating non-malignant cysts. Conclusions: The detection of a KRAS mutation in PCF is a highly specific test for mucinous cysts. It outperforms CEA for sensitivity in mucinous cyst diagnosis, but the data does not support its routine use. PMID:27092317

  9. CEA - Nuclear Energy Division. Report on Sustainable Radioactive Waste Management

    International Nuclear Information System (INIS)

    2012-12-01

    The Sustainable Radioactive Waste Management Act of June 28, 2006, specified clear guidelines for spent nuclear fuel management. It states two complementary principles: - The policy of treating and recycling spent nuclear fuel is valid for reducing the quantity and toxicity of suitably packaged ultimate radioactive waste-forms. - The reference process for high-activity and long-lived ultimate waste is deep geological disposal. The report prepared by the CEA in response to these requirements was completed after several years of work in cooperation with the other French actors in this field (EDF, AREVA) and with contribution of the CNRS and Andra. It addresses the following topics in several volumes: n guidelines for research on 4. generation systems, and a description of the various systems examined; - the results of research coordinated by the CEA on partitioning and transmutation of long-lived radioactive elements; - choices proposed for the Astrid integrated technology demonstrator - a sodium-cooled fast reactor (SFR) - and a reasonable timetable for its construction; - a review of research conducted around the world on 4. generation systems based on fast neutron reactors (FNRs). The principal results and findings compiled by the CEA from these studies are summarized in this document

  10. CEA technical-economic activity report - Year 2014

    International Nuclear Information System (INIS)

    2015-01-01

    This report presents an assessment of activities undertaken by the CEA in the field of energy technique and economy during 2014. Technical-economic studies aims at contributing to national orientations on energy, at R and D program orientations, at highlighting and strengthening synergies between nuclear technologies and new energy technologies, and at strengthening the credibility of these technologies. After a presentation of the organisation of technique and economy within the CEA, of the involved bodies and departments, of the addressed themes (photovoltaic, wind, biomass and biofuels, hydrogen-based systems, mobility, electric systems and grids), the report presents studies performed in relationship with the national energy strategy and with energy scenarios, studies performed in the nuclear field (on fourth-generation reactors, on the front-end and back-end of the fuel cycle), studies performed in the field of new energy technologies and climate (hydrogen and storage, biofuels, climate, mobility, solar, electric systems). The next part addresses academic aspects, methodological studies and modelling studies. Contributions and participations to conferences, and publications are indicated

  11. Diagnostic value of CEA and CYFRA 21-1 tumor markers in primary lung cancer.

    Science.gov (United States)

    Okamura, Kyoko; Takayama, Koichi; Izumi, Miiru; Harada, Taishi; Furuyama, Kazuto; Nakanishi, Yoichi

    2013-04-01

    Lung cancer is sometimes difficult to differentiate from benign lung diseases expressing nodular shadow in imaging study. We assessed the diagnostic value of two commonly used tumor markers in distinguishing primary lung cancer from benign lung disease. The serum levels of carcinoembryonic antigen (CEA) and cytokeratin 19 fragments (CYFRA 21-1) were retrospectively analyzed in 655 lung cancer patients and 237 patients with benign lung disease. The standard cut-off levels of 3.2 ng/mL CEA and 3.5 ng/mL CYFRA 21-1 and twice these respective levels (6.4 ng/mL and 7.0 ng/mL) were used. CEA and CYFRA 21-1 levels were elevated in 32% and 11% of benign lung disease patients, respectively. CEA sensitivity and specificity for lung cancer diagnosis was 69% and 68% respectively, while that for CYFRA 21-1 was 43% and 89%, respectively. Thus, the combined value for the specificity of the two tumor markers was greater than either alone. Patients were grouped depending on their hospital status, and prevalence rates were determined. The prevalence rate of lung cancer in admitted patients was 51%, the prevalence rate of lung cancer in outpatients was 12%, and the prevalence rate of lung cancer identified during health check-ups was 0.1%. Positive predictive values (PPVs) were calculated using Bayes' theorem, and varied with the serum tumor marker and prevalence rate: PPVs of CEA [prevalence rate] were 69.2% [51%], 22.7% [12%], and 0.22% [0.1%], while PPVs of CYFRA 21-1 were 80.3% [51%], 34.8% [12%], and 0.39% [0.1%]. However, PPVs for lung cancer diagnosis at a prevalence rate of 51% were 87.3% or higher when the patient exhibited positive CEA and CYFRA 21-1, or CEA or CYFRA 21-1 levels twice the standard cut-off. Our results indicate that CEA and CYFRA 21-1 are reliable serum tumor markers for the diagnosis of lung cancer in addition to CT scans when combined or used individually at twice the standard cut-off level in high prevalence rate groups. The prevalence rate should

  12. A new BETSI test bench at CEA/Saclay

    International Nuclear Information System (INIS)

    Nyckees, S.; Adroit, G.; Delferriere, O.; Duperrier, R.; Gauthier, Y.; Gobin, R.; Harrault, F.; Mateo, C.M.; Napoly, O.; Pottin, B.; Sauce, Y.; Senee, F.; Tuske, O.; Vacher, T.

    2012-01-01

    In the nineties, CEA has undertaken to develop the production of high intensity light ion beams from plasma generated by electron cyclotron resonance (ECR). Important results were obtained with the SILHI source in pulsed or continuous mode. Presently, CEA/Saclay is now involved in the construction of different injectors dedicated to large infrastructures like IFMIF or SPIRAL2. Other installations are also interested by high intensity ion sources like ESS or FAIR. To improve and test new sources, a new test bench named BETSI (Banc d'Etudes et de Tests des Sources d'Ions) has been operating for several years. Low energy beam line diagnostics consist of a Faraday cup, cameras and a species analyzer. The SILHI emittance scanner can also be installed on the beam line. On this test bench, different permanent magnet source configurations are tested. The paper is followed by the associated poster. (authors)

  13. Dismantling and waste management: CEA's strategy and research programs

    International Nuclear Information System (INIS)

    Behar, C.

    2012-01-01

    There are 3 main dismantling operations in CEA. First, the dismantling of the UP1 facility in the Marcoule site. UP1 was a reprocessing plant of nuclear fuels that operated from 1958 to 1997 and is now the biggest dismantling operation in the world. Its dismantling operation follows a 6-step scheme that will end in 2050. Secondly, the Passage project on the Grenoble site that concerns the dismantling of 3 research reactors (Siloette, Melusine and Siloe), of a laboratory dedicated to the analysis of active materials (Lama) and of a station for the processing of waste (Sted). Thirdly the Aladin project that concerns the installations of the Fontenay-aux-Roses site. The dismantling operations are complex because all the first research programs on high activity chemistry and on transuranium elements were performed in Fontenay-aux-Roses facilities and because ancient activities have to leave a clean place to be replaced by new ones. The radioactive waste produced by CEA enter the flow of waste that is normally processed and managed by ANDRA. Only high-activities waste have not yet a definitive solution, they are stored in waiting the opening of a geological repository. CEA leads research programs on the separation and transmutation of minor actinides and on the long-term behaviour of waste packages put in deep geological layers. (A.C.)

  14. Ior-CEA-1: Labelling, quality control and clinical evaluation

    International Nuclear Information System (INIS)

    Pimentel, G.J.

    1998-01-01

    Within the Co-ordinated Programme on Labelling, Quality Control and Evaluation of Monoclonal Antibodies, the IAEA has made a great effort to expand efficient labelling methods, mainly those with radioisotopes which have been used for radioimmunoscintigraphy. In this sense, more recently 99 Tc m has been mostly employed in the majority of the investigations due to its ideal physical characteristics. Efficient labelling of monoclonal antibodies depends on a number of factors including the method and way of the label incorporation into the protein. During the last years several direct labelling approaches have been developed, which led to attain simple and inexpensive methods for medical practice, as well as safe and stable techniques which bring accurate and good quality images. Accordingly, this paper describes the results obtained during last five years which come from the comparison among different labelling systems, passing through the quality control to test the labelled monoclonal stability and the protein bioreactivity, to continue in the clinical evaluation of ior-CEA-1, as well as the evaluation of other antibodies. Up to now we have evaluated more than 70 patients with the anti-CEA monoclonal antibody (ior-CEA-1), examined in different clinical assays such as: pilot, phase I-II and extensive phase III-IV trials, whose results are encouraging. It confirms that the employed labelling approach was safe and adequate

  15. Report transparency and nuclear safety 2007 CEA Cadarache; Rapport transparence et securite nucleaire 2007 CEA Cadarache

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This report presents the activities of the CEA Center of Cadarache for the year 2007. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially the report discusses the beginning of the RJH reactor construction, the fourth generation reactors research programs, the implementing of la Rotonde the new radioactive wastes management installation, the renovation of the LECA. (A.L.B.)

  16. Report transparency and nuclear safety 2007 CEA Marcoule; Rapport transparence et securite nucleaire 2007 CEA Marcoule

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This report presents the activities of the CEA Center of Marcoule for the year 2007. Since its creation in 1955 the center realizes industrial and scientific activities relative to the civil and military applications of the radioactivity. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially the following two base activities are detailed: Atalante and Phenix. (A.L.B.)

  17. Multiple myeloma presenting as CEA-producing rectal cancer

    Directory of Open Access Journals (Sweden)

    Giampaolo Talamo

    2010-03-01

    Full Text Available We report the case of a 57-year old patient with multiple myeloma, characterized by extramedullary involvement of the rectum at presentation. Malignant plasma cells were found to produce carcinoembryonic antigen (CEA, a tumor antigen more commonly associated with rectal adenocarcinomas.

  18. Label-free fluorimetric detection of CEA using carbon dots derived from tomato juice.

    Science.gov (United States)

    Miao, Hong; Wang, Lan; Zhuo, Yan; Zhou, Zinan; Yang, Xiaoming

    2016-12-15

    A facile-green strategy to synthesize carbon dots (CDs) with a quantum yield (QY) of nearly 13.9% has been built up, while tomato juice served as the carbon source. Interestingly, not only the precursor of CDs and the whole synthesis procedure were environmental-friendly, but this type of CDs also exhibited multiple advantages including high fluorescent QY, excellent photostability, non-toxicity and satisfactory stability. Significantly, a label-free sensitive assay for detecting carcinoembryonic antigen (CEA) in a continuous and recyclable way has been proposed on the basis of adsorption and desorption of aptamers by the surface of CDs through a competitive mechanism. To be specific, the richness of carboxyl groups of the CDs enabled strong adsorption of ssDNA to the surface of CDs through π-π stacking interactions, resulting in the effective fluorescence quenching by forming CDs-aptamer complexes. The stronger binding affinity between CEA and CEA-aptamer than the π-π stacking interactions has been taken advantage to achieve immediate recovery of the fluorescence of CDs once CEA was introduced. Thereby, quantitative evaluation of CEA concentration in a broad range from 1ngmL(-1) to 0.5ngmL(-1) with the detection limit of 0.3ngmL(-1) was realized in this way. This strategy can be applied in a recyclable way, broadening the sensing application of CDs with biocompatibility. Besides, the CDs were used for cell imaging, potentiating them towards diverse purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Clinical experience with the new tumor-associated antigen CA 19-9 compared with CEA in different neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiffer, R.; Dimitriadis, K.; Giesche, U.; Aulbert, E.; Hoffmann, B.; Schmidt, C.G.; Balzer, K.

    1984-10-01

    A new tumour-associated antigen was recently reported by Koprowski. It can be detected in human serum by a monoclonal antibody. This antigen CA 19-9 was determined in 498 patients, and simultaneous determinations of CEA were performed in 468 patients. The patients were divided into five groups: 77 non-malignant diseases of the gastrointestinal tract, 55 gastrointestinal cancer, 174 breast cancer, 101 lung cancer, and 61 other neoplasms. We found nearly the same frequency of positive CA 19-9 and CEA specimens. In the group of gastrointestinal cancer with clinically confirmed tumour 56.5% of the serum specimens were CEA positive and 54.3% were CA 19-9 positive. No patient with chronic pancreatitis (n = 11) was CA 19-9 positive, but three were CEA positive. In female breast cancer we found 48.7% CEA positive and 15.4% CA 19-9 positive, in lung cancer 40.6% CEA positive and only 11.5% CA 19-9 positive. CA 19-9 appears to be superior to CEA with respect to the discrimination of non-malignant and malignant diseases of the pancreas. The sensitivity is not sufficient for the early diagnosis of pancreatic carcinoma. In the other gastrointestinal malignomas discordant levels of both markers were detected in 10% of the patients. This means an improvement of cancer detection. The sensitivity of CA 19-9 is apparently not sufficient for breast and lung cancer.

  20. Hookah smoking and cancer: carcinoembryonic antigen (CEA) levels in exclusive/ever hookah smokers.

    Science.gov (United States)

    Sajid, Khan Mohammad; Chaouachi, Kamal; Mahmood, Rubaida

    2008-05-24

    We have recently published some work on CEA levels in hookah (also called narghile, shisha elsewhere) and cigarette smokers. Hookah smokers had higher levels of CEA than non-smokers although mean levels were low compared to cigarette smokers. However some of them were also users of other tobacco products (cigarettes, bidis, etc.). To find serum CEA levels in ever/exclusive hookah smokers, i.e. those who smoked only hookah (no cigarettes, bidis, etc.), prepared between 1 and 4 times a day with a quantity of up to 120 g of a tobacco-molasses mixture each (i.e. the tobacco weight equivalent of up to 60 cigarettes of 1 g each) and consumed in 1 to 8 sessions. Enhanced chemiluminescent immunometric technique was applied to measure CEA levels in serum samples from 59 exclusive male smokers with age ranging from 20-80 years (mean = 58.8 +/- 14.7 years) and 8-65 years of smoking (mean = 37.7 +/- 16.8). 36 non-smokers served as controls. Subjects were divided into 3 groups according to the number of preparations; the number of sessions and the total daily smoking time: Light (1; 1; 20 min to smokers (2-4; 3-8; >2 hrs to smokers (mean: 3.58 +/- 2.61 ng/ml; n = 59) were not significantly different (p non-smokers (2.35 +/- 0.71 ng/ml). Mean levels in light, medium and heavy smokers were: 1.06 +/- 0.492 ng/ml (n = 5); 2.52 +/- 1.15 ng/ml (n = 28) and 5.11 +/- 3.08 ng/ml (n = 26) respectively. The levels in medium smokers and non-smokers were also not significantly different (p smokers, the CEA levels were significantly higher than in non-smokers (p smokers were low compared to cigarette smokers. However, heavy hookah smoking substantially raises CEA levels. Low-nitrosamines smokeless tobacco of the SNUS Swedish type could be envisaged as an alternative to smoking for this category of users and also, in a broad harm reduction perspective, to the prevalent low-quality moist snuff called naswar.

  1. ECR Light Ion Sources at CEA/Saclay%CEA/Saclay的ECR轻离子离子源

    Institute of Scientific and Technical Information of China (English)

    R.Gobin; P-A.Leroy; O.Tuske; D.Uriot; P-Y.Beauvais; A.Ben Ismail; D.Bogard; O.Delferriere; D.de Menezes; R.Duperrier; Y.Gauthier; F.Harrault

    2007-01-01

    In the beginning of the 90s,T.Taylor and his collaborators demonstrated ECR sources operating at low frequency (I.e.2.45GHz) are able to produce very intense single charge light ion beams.At CEA/Saclay,the SILHI source developments started in 1995.Since 1997 more than 100mA proton or deuteron beams are routinely produced in pulsed or continuous mode.To comply with ADS reliability constraint,important improvements have been performed to increase the installation reliability.Moreover,to optimize the beam transport in the low energy beam line,the extraction system was carefully designed and space charge compensation studies were undertaken.An important step has been reached in 2005 with the development of a permanent magnet source able to produce a total beam of 109mA at 85kV.A new test bench named BETSI,especially dedicated to permanent magnet source developments,is presently under construction.It will allow analysing positive or negative extracted beams up to 50keV and 100mA.In addition,for several years work has been done to optimize the production of negative hydrogen ion beam with such an ECR source.Recent analysis pushed towards the construction of a new set up based on a multicusp magnetic configuration.After a brief overview of the CEA/Saclay source developments,this article will point out on the recent results and present status.

  2. Detailed design studies at CEA for JT-60SA TF coils

    International Nuclear Information System (INIS)

    Decool, P.; Marechal, J.L.; Portafaix, C.; Lacroix, B.; Gros, G.; Verger, J.M.

    2011-01-01

    Following a first conceptual design activity in which the general design of the JT-60SA TF system was defined and frozen in agreement with all the participants in the project (CEA, ENEA, F4E), a second phase had to be launched to deal with the detailed design. In this paper, we present the work performed at CEA on the TF coil design during this second phase. Part of this work, concerns the determination of conductor hydraulic performances during operation as well as in factory. The thermohydraulic of the conductor was also assessed to confirm the need of helium inlets and a specific design was developed and qualified to be compatible with the available hydraulic performance of the cryoplant. The mechanical behavior is still to be assessed and qualified. Last but not least, the inner electrical joints of the coil have been modified with respect to the original twin-box design developed by CEA for the ITER coils in order to simplify the fabrication process. A dedicated qualification program for their manufacture is ongoing.

  3. Efficient tumor regression by adoptively transferred CEA-specific CAR-T cells associated with symptoms of mild cytokine release syndrome.

    Science.gov (United States)

    Wang, Linan; Ma, Ning; Okamoto, Sachiko; Amaishi, Yasunori; Sato, Eiichi; Seo, Naohiro; Mineno, Junichi; Takesako, Kazutoh; Kato, Takuma; Shiku, Hiroshi

    2016-01-01

    Carcinoembryonic antigen (CEA) is a cell surface antigen highly expressed in various cancer cell types and in healthy tissues. It has the potential to be a target for chimeric antigen receptor (CAR)-modified T-cell therapy; however, the safety of this approach in terms of on-target/off-tumor effects needs to be determined. To address this issue in a clinically relevant model, we used a mouse model in which the T cells expressing CEA-specific CAR were transferred into tumor-bearing CEA-transgenic (Tg) mice that physiologically expressed CEA as a self-antigen. The adoptive transfer in conjunction with lymphodepleting and myeloablative preconditioning mediated significant tumor regression but caused weight loss in CEA-Tg, but not in wild-type mice. The weight loss was not associated with overt inflammation in the CEA-expressing gastrointestinal tract but was associated with malnutrition, reflected in elevated systemic levels of cytokines linked to anorexia, which could be controlled by the administration of an anti-IL-6 receptor monoclonal antibody without compromising efficacy. The apparent relationship between lymphodepleting and myeloablative preconditioning, efficacy, and off-tumor toxicity of CAR-T cells would necessitate the development of CEA-specific CAR-T cells with improved signaling domains that require less stringent preconditioning for their efficacy. Taken together, these results suggest that CEA-specific CAR-based adoptive T-cell therapy may be effective for patients with CEA + solid tumors. Distinguishing the fine line between therapeutic efficacy and off-tumor toxicity would involve further modifications of CAR-T cells and preconditioning regimens.

  4. Efficacy of 18F-FDG PET/CT in investigation of elevated CEA without known primary malignancy

    Directory of Open Access Journals (Sweden)

    Simon Sin-man Wong

    2016-01-01

    Full Text Available Aim: To evaluate the efficacy of 18flurodeoxyglucose positron emission tomography/computer tomography (18F-FDG PET/CT in investigating patients with elevated carcinoembryonic antigen (CEA and without known primary malignancy, and the impact of PET/CT findings on patient management. Setting and Design: PET/CT scans done in a tertiary hospital between December 2007 and February 2012 for elevated CEA in patients without known primary malignancy were retrospectively reviewed. Materials and Methods: The PET/CT findings, patients' clinical information, level of CEA, histological diagnosis, and subsequent management were retrieved by the electronic patient record for analysis. Statistical Analysis: Data were analyzed using SPSS version 19. Results: One hundred and one PET/CT scans were performed for patients with elevated CEA. Fifty-eight of these were performed for patients with known primary malignancy and were excluded; 43 PET/CT scans were performed for patients without known primary malignancy and were included. Thirty-three (77% had a positive PET/CT. Among the 32 patients with malignancy, 15 (47% suffered from lung cancer and 8 (25% suffered from colorectal cancer. The sensitivity (97%, specificity (82%, positive predictive value (94%, negative predictive value (90%, and accuracy (93% were calculated. Thirty (91% patients had resultant change in management. The mean CEA level for patients with malignancy (46.1 ng/ml was significantly higher than those without malignancy (3.82 ng/ml (P < 0.05. In predicting the presence of malignancy, a CEA cutoff at 7.55 ng/ml will achieve a sensitivity of 91% and a specificity of 73%. Conclusion: PET/CT, in our study population, appears to be sensitive, specific, and accurate in investigating patients with elevated CEA and without known primary malignancy. In addition to diagnosis of underlying primary malignancy, PET/CT also reveals occult metastases which would affect patient treatment options.Its role in

  5. Evaluation of the reliability concerning the identification of human factors as contributing factors by a computer supported event analysis (CEA)

    International Nuclear Information System (INIS)

    Wilpert, B.; Maimer, H.; Loroff, C.

    2000-01-01

    The project's objectives are the evaluation of the reliability concerning the identification of Human Factors as contributing factors by a computer supported event analysis (CEA). CEA is a computer version of SOL (Safety through Organizational Learning). Parts of the first step were interviews with experts from the nuclear power industry and the evaluation of existing computer supported event analysis methods. This information was combined to a requirement profile for the CEA software. The next step contained the implementation of the software in an iterative process of evaluation. The completion of this project was the testing of the CEA software. As a result the testing demonstrated that it is possible to identify contributing factors with CEA validly. In addition, CEA received a very positive feedback from the experts. (orig.) [de

  6. The possible role of tumor antigen CA 15-3, CEA and ferritin in malignant and benign disease

    Directory of Open Access Journals (Sweden)

    Nafija Serdarević

    2012-09-01

    Full Text Available Introduction: Serum CA15-3 has been one of the most reliable tumor markers used in monitoring of breast cancer patients. To increase its sensitivity, the combined measurement of other tumor markers (CEA and ferritin with CA15-3 was investigated. The aim of this study was determination of CA 15-3, CEA and ferritin in female patients with breast cancer, lung cancer and mastitisMethods: 300 patients with carcinoma, hospitalized at Department of Gynecologic Oncology and Department for Oncology at the University Clinics Center of Sarajevo and 200 healthy subjects were compared.Results: In patients with breast cancer the mean value of tumor markers were CEA 155.61 ng/mL, CA 15-3 106.38 U/mL and ferritin 197.03 ng/mL. In patients with lung cancer CEA was 58.97 ng/ml, CA 15-3 40.62 U/mL and ferritin 544.16 ng/mL. Patients with mastitis had CEA 5.17 ng/mL, CA 15-3 112.67 U/mL and ferritin 174.92 ng/mL. The control group had values of tumor markers CEA 1.62 ng/mL, CA 15-3 11.72 U/mL and ferritin 85.35 ng/mL. We found good correlation between CA 15-3 and CEA correlation coeffi cient was r = 0.750. There was a low correlation between CA 15-3 and ferritin with correlation coeffi cient r = 0.274.Conclusions: The CA 15-3 and CEA are useful markers in patients with confi rmed diagnosis of breast and lung cancers. The ferritin concentration has not increased in patients with breast cancer but it increased inlung patients. The future study has to make investigations of tumor markers and ferritin in different stage of breast cancer.

  7. Treatment with Ca-DTPA of internal contaminations by plutonium and americium: Recommendations for writing protocols in Cea and AREVA centers; Traitement par le Ca-DTPA des contaminations internes par le plutonium et l'americium: recommandations pour la redaction de protocoles dans les centres CEA et AREVA

    Energy Technology Data Exchange (ETDEWEB)

    Grappin, L. [CEA Cadarache, DEN, Service de Sante au Travail, 13 - Saint-Paul-lez-Durance (France); Legoff, J.P.; Andre, F. [CEA Valduc, Service de Sante au Travail, 21 - Is-sur-Tille (France); Carbone, L.; Agrinier, A.L. [CEA Marcoule, DEN, Service de Sante au Travail, 30 (France); Courtay, C.; Aninat, M. [AREVA, Service de Sante au Travail, La Hague, 50 - Beaumont-Hague (France); Amabile, J.C. [SPRA, HIA Percy, 92 - Clamart (France); Florin, A. [CEA Saclay, SDM Service de Sante au Travail, 91 - Gif-sur-Yvette (France)

    2009-10-15

    The purpose of this document is to provide physicians working in a B.N.F. (Basic Nuclear Facility) with recommendations for the drafting of Ca-DTPA treatment protocols for internal contamination by actinides. These recommendations are based on the results of injections carried out by Cea and AREVA doctors in a working group, with the collaboration of the Army Radiation Protection Service. The study focused on Ca-DTPA IV injection. Other dosage forms, routes of administration as well as adjuvant treatments are also mentioned. For cases of contaminated wounds and inhalation, indicators for treatment with Ca-DTPA, particularly its initialization, the dosage, duration, frequency of administration, the criteria for ending the treatment, then its efficiency and dosimetry gain are covered. A guide for the prescription of the radio toxicological monitoring necessary for the treatment and the dosimetric evaluation is proposed. (authors)

  8. Overview of CEA research in the field of radionuclides migration

    International Nuclear Information System (INIS)

    Poinssot, Ch.; Trotignon, L.; Tevissen, E.

    2006-01-01

    This report presents a synthetic status of the researches conducted within the Nuclear Energy Division (CEA/DEN) in the field of radionuclides migration in three specific areas which have been chosen for their representativeness and potential impact: the migration of RN in PWR reactors, the migration of RN from a deep geological repository and the migration processes in the surface environments. In addition, some status is given about more generic research which is conducted in the field of RN speciation in the aqueous phase and at the interfaces and regarding chemistry / transport couplings. Additional information about the human and technical means involved in these fields of research in CEA/DEN is finally given in the Appendix. (authors)

  9. Fusion technology. Annual report of the Association CEA/EURATOM 1997

    International Nuclear Information System (INIS)

    Magaud, P.; Le Vagueres, F.

    1998-01-01

    The research and development work performed by the French EURATOM-CEA Association for fusion technology is part of the Fusion Programme of the European Community. This report compiles the work carried out during the year 1997 as follows: The ITER CEA activities and related developments are described in the first section (plasma facing components, vacuum vessel and shield, magnets, remote handling, safety); The second part is dedicated to the Long Term activities as Blankets and material developments, long term safety, socio-economic problem; The Underlying Technology activities are compiled in the third part of this report (plasma facing components, vacuum vessel and shield, magnets, remote handling, safety); And the fourth part describes the inertial confinement studies. (K.A.)

  10. Fusion technology. Annual report of the Association CEA/EURATOM 1997

    Energy Technology Data Exchange (ETDEWEB)

    Magaud, P.; Le Vagueres, F

    1998-12-31

    The research and development work performed by the French EURATOM-CEA Association for fusion technology is part of the Fusion Programme of the European Community. This report compiles the work carried out during the year 1997 as follows: The ITER CEA activities and related developments are described in the first section (plasma facing components, vacuum vessel and shield, magnets, remote handling, safety); The second part is dedicated to the Long Term activities as Blankets and material developments, long term safety, socio-economic problem; The Underlying Technology activities are compiled in the third part of this report (plasma facing components, vacuum vessel and shield, magnets, remote handling, safety); And the fourth part describes the inertial confinement studies. (K.A.)

  11. Fusion technology. Annual report of the Association CEA/EURATOM 1997

    Energy Technology Data Exchange (ETDEWEB)

    Magaud, P; Le Vagueres, F

    1999-12-31

    The research and development work performed by the French EURATOM-CEA Association for fusion technology is part of the Fusion Programme of the European Community. This report compiles the work carried out during the year 1997 as follows: The ITER CEA activities and related developments are described in the first section (plasma facing components, vacuum vessel and shield, magnets, remote handling, safety); The second part is dedicated to the Long Term activities as Blankets and material developments, long term safety, socio-economic problem; The Underlying Technology activities are compiled in the third part of this report (plasma facing components, vacuum vessel and shield, magnets, remote handling, safety); And the fourth part describes the inertial confinement studies. (K.A.)

  12. Decommissioning of the Nuclear Licensed Facilities at the Fontenay aux Roses CEA Center

    International Nuclear Information System (INIS)

    Jeanjacques, Michel; Piketty, Laurence; Mandard, Lionel; Pedron, Guy; Boissonneau, Jean Francois; Fouquereau, Alain; Pichereau, Eric; Lethuaire, Nathalie; Estivie, David; Binet, Cedric; Meden, Igor

    2008-01-01

    This is a summary of the program for the decommissioning of all the CEA's facilities in Fontenay aux Roses. The particularity of this center is that it is located in a built-up area. Taking into account the particularities of the various buildings and the levels of radioactivity in them, it was possible to devise a coherent, optimized program for the CEA-FAR licensed nuclear facility decommissioning operations

  13. The releases control and the environment survey of the Cea Centers

    International Nuclear Information System (INIS)

    2002-01-01

    The Cea sets the environment protection in the heart of its security policy, which is based on the mastership of risks resulting from the researches activities and installations development. This policy aims to reduce as small as possible compared with the technical and economical necessities, the impact of its activities on the human and the environment. This document, takes stock for the year 2002, of the liquid and gas radioactive effluents releases as also of the radioactivity level around the Cea Centers, by a systematic monitoring of the atmosphere, the waters, the vegetation and the milk. (A.L.B.)

  14. Further development of the radioimmunoassay for carcinoembryonic antigen (CEA) and research on normal values in men, women, smokers and non-smokers

    International Nuclear Information System (INIS)

    Kompan, Z.

    1985-01-01

    In this work the increase in the sensitivity of detection of the assay was tested and the methods of sequential saturation and the equilibrium procedure were checked over. The higher detection sensitivity was attained by means of the sequential saturation. The increase in the incubation time of up to 72 hours resulted in a further increase of the detection sensitivity compared to 48 hours. Cattle serum, artificial buffer medium and CEA-poor human plasma were studied for their usefulness as a matrix for CEA standards. Moreover impure CEA and HPLC-cleaned CEA were also studied for the standards. The results show that HPLC-cleaned CEA gives a better accuracy. The production of standard rows in CEA-poor human plasma showed itself to be superior compared to the buffer medium and cattle serum. The reproducibility of the CEA determination was checked over. (orig./PW) [de

  15. APR1400 CEA Withdrawal at Power Accident Analysis using KNAP

    International Nuclear Information System (INIS)

    Lee, Dong-Hyuk; Yang, Chang-Keun; Kim, Yo-Han; Sung, Chang-Kyung

    2006-01-01

    KEPRI (Korea Electric Power Research Institute) has been developing safety analysis methodology for non- LOCA (Loss Of Coolant Accident) analysis of OPR1000 (Optimized Power Reactor 1000, formerly KSNP). The new methodology, named KNAP (Korea Non-LOCA Analysis Package), uses RETRAN as the main system analysis code. RETRAN code is a non- LOCA safety analysis code developed by EPRI. The new methodology will replace existing CE (Combustion Engineering) supplied codes and methodologies currently used in non-LOCA analysis of OPR1000. In this paper, we apply KNAP methodology to APR1400 (Advanced Power Reactor 1400). The CEA (Control Element Assembly) withdrawal at power accident is one of the 'reactivity and power distribution anomalies' events and the results are typically described in the chapter 15.4.2 of SAR (Safety Analysis Report). The APR1400 has been designed to generate 1,400MWe of electricity with advanced features for greatly enhanced safety and economic goals. The CEA withdrawal at power analysis in APR1400 SSAR (Standard Safety Analysis Report) is analyzed with CESEC-III computer code. In this study, to confirm the applicability of the KNAP methodology and code system to APR1400, CEA withdrawal at power accident is analyzed using RETRAN code and it is compared with results from APR1400 SSAR

  16. Rapport sur le développement dans le monde sur le thème du rôle ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    ... rural et sont tributaires principalement de l'agriculture pour assurer leur subsistance. Ce projet permettra de veiller à ce qu'une place soit accordée aux travaux de recherche financés par le CRDI, aux points de vue différents et aux auteurs de l'hémisphère Sud dans le Rapport sur le développement dans le monde 2008.

  17. Carcinoembryonic Antigen (CEA) in colorectal cancer follow-up

    NARCIS (Netherlands)

    Verberne, Charlotte

    2016-01-01

    Colorectal cancer follow-up aims to detect recurrent disease as soon as possible, since earlier detection of recurrent disease is associated with greater chances for cure. A part of follow-up is the measurement of Carcinoembryonic Antigen (CEA) in the blood of the patient. This tumor marker is

  18. Importance of low-level radioactive wastes in dismantling strategy in CEA (FRANCE)

    International Nuclear Information System (INIS)

    Lafaille, C.

    1991-01-01

    This paper describes the advance used in C.E.A. to realize dismantling operations in the best technical and economical conditions. Particularly, for low-level radioactive waste management CEA's advance defines, first, the final destination of dismantling materials: - recycling in public lands for level activity inferior to 1 Bq/g; directly or after transformation (melting, calcination, extrusion) - storage in a ground disposal, after compacting, encapsulation or drumming. Two examples are given: - Marcoule G2 - G3 reactor dismantling - Gaseous diffusion plants demolition (COGEMA Pierrelatte)

  19. L-dopa, biperideno e excreção sebácea na doença de Parkinson

    Directory of Open Access Journals (Sweden)

    João C. B. Villares

    1989-03-01

    Full Text Available A excreção sebácea frontal de 47 parkinsonianos «de novo» antes e após tratamento com anticolinérgico (biperideno, levodopa + IDAA e bromocriptina foi avaliada pelo método do ácido ósmico. Outros 100 parkinsonianos sob terapêutica crônica com biperideno, levodopa + IDAA ou associação de ambos foram avaliados. Parkinsonianos «de novo» do sexo masculino apresentam valores de excreção sebácea significativamente mais elevados em relação às mulheres. Verificou-se que biperideno não foi eficaz em reduzir o grau de excreção sebácea. Já, em relação a L-dopa + IDAA constatou-se que a droga foi efetiva em reduzir o grau de excreção sebácea (NC e TRE tanto no sexo masculino quanto no feminino. Em relação à bromocriptina (l0mg/dia também constatou-se que houve redução da excreção sebácea no sexo masculino. Correlação significante positiva foi verificada entre o NC, tremor, bradicinesia, hipertonia, alterações da marcha e postura e incapacidade funcional, entre parkinsonianos do sexo masculino e faixa etária 50-59 anos, no período pré-tratamento. Após o período de tratamento não mais havia correlação entre excreção sebácea e as manifestações neurológicas da doença de Parkinson. Entre parkinsonianos sob terapêutica crônica verificou-se correlação positiva e significante entre excreção sebácea e bradicinesia. O grau de excreção sebácea de parkinsonianos «de novo» sem tratamento não difere do grau daqueles sob tratamento crônico, exceção feita a parkinsonianos com idade > 60 anos, em que verificou-se maior grau de excreção sebácea (NC e TRE em relação ao mesmo sexo e faixa etária, sem tratamento. L-dopa + IDAA foi eficiente em reduzir o grau de excreção sebácea de parkinsonianos «de novo», tornando-a significativamente menor em relação àqueles sob tratamento crônico. Não há diferença entre o grau de excreção sebácea de parkinsonianos «de novo» sem tratamento e

  20. Significance of changes of serum NSE and CEA levels in patients with pneumonia and malignant tumors

    International Nuclear Information System (INIS)

    Liu Hengguo; Luo Nanping; Wang Ruishan; Bai Lu

    2005-01-01

    Objective: To investigate the significance of changes of serum NSE and CEA levels in patients with pneumonia and malignant tumors. Methods: Serum NSE (with RIA) and CEA (with ECLIA) levels in patients with pneumonia or various kinds of malignant tumors (altogether 140 patients) and 32 controls. Results: Serum NSE and CEA levels were significantly higher in patients with lung cancer, gastric cancer, renal cancer, brain tumor and pneumonia than those in the controls (P<0.05,P <0. 05 ,P <0. 01, P<0.01, P<0.01). Positive rate of serum NSE highest in patients with pneumonia, followed successively by renal cancer, brain tumor and lung cancer. NSE levels were positively correlated with CEA levels (r=0.29, P<0.05). Conclusion: As a tumor marker, NSE has important clinical significance in the diagnoses of malignant tumor and pneumonia. (authors)

  1. Intracellular Targeting of CEA Results in Th1-Type Antibody Responses Following Intradermal Genetic Vaccination by a Needle-Free Jet Injection Device

    Directory of Open Access Journals (Sweden)

    Susanne Johansson

    2007-01-01

    Full Text Available The route and method of immunization, as well as the cellular localization of the antigen, can influence the generation of an immune response. In general, intramuscular immunization results in Th1 responses, whereas intradermal delivery of DNA by gene gun immunization often results in more Th2 responses. Here we investigate how altering the cellular localization of the tumor antigen CEA (carcinoembryonic antigen affects the quality and amplitude of DNA vaccine-induced antibody responses in mice following intradermal delivery of DNA by a needle-free jet injection device (Biojector. CEA was expressed either in a membrane-bound form (wild-type CEA or in two truncated forms (CEA6 and CEA66 with cytoplasmic localization, where CEA66 was fused to a promiscuous T-helper epitope from tetanus toxin. Repeated intradermal immunization of BALB/c mice with DNA encoding wild-type CEA produced high antibody titers of a mixed IgG1/IgG2a ratio. In contrast, utilizing the DNA construct that resulted in intracellular targeting of CEA led to a reduced capacity to induce CEA-specific antibodies, but instead induced a Th1-biased immune response.

  2. The CEA program on boiling noise detection

    International Nuclear Information System (INIS)

    Le Guillou, G.; Brunet, M.; Girard, J.P.; Flory, D.

    1982-01-01

    The research program on the application of noise analysis on boiling detection in a fast subassembly began 10 years ago at the CEA, mainly in the Nuclear Center of Cadarache. Referring exclusively to the aspects of premature detection of the boiling phenomenon it can be said that this program is organized around the following three detection techniques: acoustic noise analysis; neutron noise analysis; temperature noise analysis. Its development is in conjunction with in-pile experiments in Phenix or Rapsodie as well as 'ex-pile' (boiling experiments through electric heating). Three detection techniques were developed independent of each other, but that they were regrouped during the execution of the most important experiments and with the 'Super Phenix' project. The noise analysis system ANABEL with which Superphenix will be equipped with shows the industrial interest in detection methods based on noises. One of the results of the CEA program today is the possibility to evaluate the potential capacity for boiling detection in the subassembly. But in order to obtain the necessary funds from the commercial nuclear plant operators it is mandatory to have successful demonstrations which will be the objective of the future program

  3. Differential diagnostic value of combined detection of serum CA153, CEA and TPA levels in patients with breast tumor

    International Nuclear Information System (INIS)

    Ding Wei

    2007-01-01

    Objective: To assess the differential diagnostic value of combined detection of serum CA153, CEA and TPA levels in patients with breast tumor. Methods: Serum levels of CA153, CEA and TPA were measured with RIA in 269 patients with breast tumor and 150 controls. Results: The serum levels of CA153, CEA and TPA in patients with breast cancer were significantly higher than those in the patients with benign breast tumor and controls. The positive rate of CA153 was 63.8% in the patients with breast cancer and that of CEA and TPA was 22.4% and 62.1% respectively, with combined detection of CA153 and CEA, the positive rate was 69.8%, with CA153 and TPA combined, the positive rate was 87.1%, with the three marker combined, the positive rate was 90.5%. The specificity was 77.9% with CA153, 77.9% with CA153 and CEA, 71.9% with CA153 and TPA, and 73.4% with all the three markers combined. Conclusion: The positive rate was increased remarkably with combined detection of CA153, CEA and TPA, however the specificity was not much changed, so the combined detection was valuable for differential diagnosis. (authors)

  4. Elevated Levels of Serum Tumor Markers CEA and CA15-3 Are Prognostic Parameters for Different Molecular Subtypes of Breast Cancer.

    Directory of Open Access Journals (Sweden)

    Yingbo Shao

    Full Text Available The utility of measuring carcinoembryonic antigen(CEA and cancer antigen 15-3 (CA15-3 levels in patients with breast cancer remains controversial. The present study aims to investigate the prognostic value of preoperative serum CEA and CA15-3 levels in breast cancer patients.Serum preoperative CEA and CA 15-3 concentration levels were measured in a total of 432 breast cancer patients. The association of tumor markers levels with clinicopathological parameters and outcomes were analyzed.Elevated serum levels of CEA and CA15-3 were identified in 47 (10.9% and 60(13.9% patients, respectively. Larger tumor size, advanced axillary lymph nodal and TNM stage exhibited higher proportion of elevated CEA and CA15-3 levels. The elevation of CEA levels was significantly greater in patients with HER2 positive tumors, and the elevation of CA15-3 levels was significantly greater in ER negative breast patients. Univariate and multivariate Cox's regression analysis revealed that elevated preoperative CEA and CA 15-3 levels were independent prognostic factors for DFS and OS. When considering the combination of both markers levels, patients with both elevated markers presented the worst survival. Independent prognostic significance of elevated preoperative serum CEA and CA15-3 levels were reconfirmed in Luminal B breast cancer.Preoperative serum levels of CEA and CA15-3 are independent prognostic parameters for breast cancer.

  5. Elevated Levels of Serum Tumor Markers CEA and CA15-3 Are Prognostic Parameters for Different Molecular Subtypes of Breast Cancer.

    Science.gov (United States)

    Shao, Yingbo; Sun, Xianfu; He, Yaning; Liu, Chaojun; Liu, Hui

    2015-01-01

    The utility of measuring carcinoembryonic antigen(CEA) and cancer antigen 15-3 (CA15-3) levels in patients with breast cancer remains controversial. The present study aims to investigate the prognostic value of preoperative serum CEA and CA15-3 levels in breast cancer patients. Serum preoperative CEA and CA 15-3 concentration levels were measured in a total of 432 breast cancer patients. The association of tumor markers levels with clinicopathological parameters and outcomes were analyzed. Elevated serum levels of CEA and CA15-3 were identified in 47 (10.9%) and 60(13.9%) patients, respectively. Larger tumor size, advanced axillary lymph nodal and TNM stage exhibited higher proportion of elevated CEA and CA15-3 levels. The elevation of CEA levels was significantly greater in patients with HER2 positive tumors, and the elevation of CA15-3 levels was significantly greater in ER negative breast patients. Univariate and multivariate Cox's regression analysis revealed that elevated preoperative CEA and CA 15-3 levels were independent prognostic factors for DFS and OS. When considering the combination of both markers levels, patients with both elevated markers presented the worst survival. Independent prognostic significance of elevated preoperative serum CEA and CA15-3 levels were reconfirmed in Luminal B breast cancer. Preoperative serum levels of CEA and CA15-3 are independent prognostic parameters for breast cancer.

  6. Clinical significance of changes of serum of P-selectin, CEA and TSGF levels after operation in patients with rectal cancer

    International Nuclear Information System (INIS)

    Wang Zhizhong; Huang Jin

    2007-01-01

    Objective: To study the clinical significance of postoperative changes of serum P-selectin, CEA and TSGF levels in patients with rectal cancer. Methods: Serum CEA (with RIA), P-selectin (with ELISA), and TSGF (with biochemistry levels were determined) in 32 patients with rectal cancer both before and after operation as well as in 30 controls. Results: Before operation, the serum P-selectin, CEA and TSGF levels were significantly higher than those in controls (P < 0.01), Twenty -two of the 30 patients underwent operative therapy showed no sign of recurrence at one year and their serum P-selectin, CEA and TSGF levels dropped to within normal range. Hower in the 8 patients with recurrence, the serum levels of P-selectin, CEA and TSGF remained abnormally high. Conclusion: Serum P-selectin, CEA and TSGF levels were closely related to the diseases process of rectal cancer and were of prognostic values. (authors)

  7. Relationship between peripheral and mesenteric serum levels of CEA and CA 242 with staging and histopathological variables in colorectal adenocarcinoma Níveis séricos periféricos e mesentéricos de CEA e CA 242, estadiamento e variáveis histopatológicas no adenocarcinoma colorretal

    Directory of Open Access Journals (Sweden)

    Mauro Lamelas Cardoso

    2009-10-01

    Full Text Available PURPOSE: To compare histopathological variables and staging in colorectal adenocarcinoma cases with CEA and CA 242 in peripheral and mesenteric blood. METHODS: In 169 individuals underwent surgery for colorectal cancer, CEA and CA 242 were analyzed and compared to mesenteric and peripheral blood and correlated with macroscopic tumor's morphology and size, degree of cell differentiation, venous, neural and lymphatic involvement and TNM classification. RESULTS: There was a difference between the mesenteric (M and peripheral (P serum levels of CEA (p=0.020. Higher levels of markers were correlated with venous invasion CEA (P p=0.013, CEA (M p=0.05, CA 242 (M p=0.005 and CA 242 (P p=0.038; with advanced staging CEA (P OBJETIVO: Comparar variáveis histopatológicas e graus de estadiamento do adenocarcinoma colorretal com níveis sanguíneos periféricos e mesentéricos de CEA e CA-242. MÉTODOS: Em 169 doentes submetidos ao tratamento cirúrgico por adenocarcinoma colorretal, CEA e CA-242 foram analisados e comparados quanto aos níveis sanguíneos periféricos e mesentéricos e correlacionados com o tamanho e a morfologia macroscópica do tumor, grau de diferenciação celular, invasões venosa, linfática, neural e a classificação TNM. RESULTADOS: Verificou-se diferença significante entre o nível sérico mesentérico e periférico de CEA (p= 0,02. Níveis séricos mais elevados dos marcadores foram observados e correlacionados com invasão venosa, CEA (P p=0,013, CEA(M, p=0,05, CA-242 (M p=0,005 e CA-242 (P p=0,038. Grau de estadiamento TNM avançado foi associado com CEA(P < CEA(M p<0,05, CA-242(P < CA-242(M p<0,05. Nas maiores dimensões tumorais constatou-se CEA(P < CEA(M p=0,001 e CA 242 (P < CA 242 (M (p < 0.001. O CA 242 periférico e mesentérico aumentados associaram-se com a invasão neural, p=0.014 e p=0.003, respectivamente. CONCLUSÕES: O nível sérico mesentérico de CEA é superior ao nível sérico periférico. Os níveis s

  8. General review of multispectral cooled IR development at CEA-Leti, France

    Science.gov (United States)

    Boulard, F.; Marmonier, F.; Grangier, C.; Adelmini, L.; Gravrand, O.; Ballet, P.; Baudry, X.; Baylet, J.; Badano, G.; Espiau de Lamaestre, R.; Bisotto, S.

    2017-02-01

    Multicolor detection capabilities, which bring information on the thermal and chemical composition of the scene, are desirable for advanced infrared (IR) imaging systems. This communication reviews intra and multiband solutions developed at CEA-Leti, from dual-band molecular beam epitaxy grown Mercury Cadmium Telluride (MCT) photodiodes to plasmon-enhanced multicolor IR detectors and backside pixelated filters. Spectral responses, quantum efficiency and detector noise performances, pros and cons regarding global system are discussed in regards to technology maturity, pixel pitch reduction, and affordability. From MWIR-LWIR large band to intra MWIR or LWIR bands peaked detection, results underline the full possibility developed at CEA-Leti.

  9. Comparison of Serum CA72-4 and CEA Levels in Patient with Endoscopically Suspected Gastric Carcinoma.

    Science.gov (United States)

    Rehena, Z; Ghosh, C K; Afroz, F; Alam, M B; Ferdousi, S; Mahmuduzzaman, M; Sultana, T; Ahmed, A N

    2015-07-01

    Several serum tumour markers have been described for gastric cancer. Preoperative level of tumor marker helps to predict the diagnosis of gastric carcinoma. CA72-4 as a serum tumour marker for gastric cancer is evaluated, and compared its utility in this regard with that of carcinoembryonic antigen (CEA). Analysis of gastric carcinoma by serum levels of CEA and CA72-4 and their correlation with histopathology help the clinician to develop his management strategies for gastric carcinoma. A prospective observational study was carried out in the Department of Clinical Pathology, Bangabandhu Sheikh Mujib Medical University (BSMMU) in collaboration with Department of Surgery BSMMU, DMCH, Delta Hospital Limited, Dhaka, during the period of October 2010 to September 2011. Serum CA72-4 and CEA were analyzed in 71 endoscopically suspected patients for gastric carcinoma. Among them 58 cases were diagnosed as malignant gastric disease and 13 cases were nonmalignant gastric disease. Sensitivity of CA 72-4 and CEA were 48.3% and 31% respectively and specificity were 92.3% and 76.9% respectively. In poorly differentiated carcinoma, positivity for CA72-4 and CEA were 55.6% and 36.1% respectively. Because of the high positivity of CA72-4 in poorly differentiated carcinoma, CA72-4 is reliable tumour marker in advanced cases. As the sensitivity of CA72-4 was more than that of CEA in diagnosis of gastric cancer, CA72-4 can be used in conjunction with other diagnostic tests like endoscopy that would be more helpful for the patients.

  10. Development of radiopharmaceuticals based on aptamers: selection and characterization of DNA aptamers for CEA

    International Nuclear Information System (INIS)

    Correa, C.R.; Andrade, A.S.R.; Augusto-Pinto, L.; Goes, A.M.

    2011-01-01

    Colorectal cancer is among the top four causes of cancer deaths worldwide. Carcinoembryonic antigen (CEA) is a complex intracellular glycoprotein produced by about 90% of colorectal cancers. CEA has been identified as an attractive target for cancer research because of its pattern of expression in the surface cell and its likely functional role in tumorigenesis. Research on the rapid selection of ligands based on the SELEX (systematic evolution of ligands by exponential enrichment) forms the basis for the development of high affinity and high specificity molecules, which can bind to surface determinants of tumour cells, like CEA. The oligonucleotides ligands generated in this technique are called aptamers. Aptamers can potentially find applications as therapeutic or diagnostic tools for many kind of diseases, like a tumor. Aptamers offer low immunogenicity, good tumour penetration, rapid uptake and fast systemic clearance, which favour their application as effective vehicles for radiotherapy. In addition aptamers can be labeled with different radioactive isotopes. The aim of this work was select aptamers binding to the CEA tumor marker. The aptamers are obtained through by SELEX, in which aptamers are selected from a library of random sequences of synthetic DNA by repetitive binding of the oligonucleotides to target molecule (CEA). Analyses of the secondary structure of the aptamers were determined using the m fold toll. Three aptamers were selected to binding assay with target cells. These aptamers were confirmed to have affinity and specific binding for T84 cell line (target cell), showed by confocal imaging. We are currently studying the potential efficacy of these aptamers as targeted radiopharmaceuticals, for use as imaging agents or therapeutic applications. The development of aptamers specific to CEA open new perspectives for colorectal cancer diagnosis and treatment. Acknowledgments: This investigation was supported by the Centro de Desenvolvimento da

  11. Development of radiopharmaceuticals based on aptamers: selection and characterization of DNA aptamers for CEA

    Energy Technology Data Exchange (ETDEWEB)

    Correa, C.R.; Andrade, A.S.R., E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Augusto-Pinto, L. [BioAptus, Belo Horizonte, MG (Brazil); Goes, A.M., E-mail: goes@icb.ufmg.br [Departamento de Imunologia e Bioquimica. Instituto de Ciencias Biologicas. Universidade Federal de Minas Gerais. Belo Horizonte, MG (Brazil)

    2011-07-01

    Colorectal cancer is among the top four causes of cancer deaths worldwide. Carcinoembryonic antigen (CEA) is a complex intracellular glycoprotein produced by about 90% of colorectal cancers. CEA has been identified as an attractive target for cancer research because of its pattern of expression in the surface cell and its likely functional role in tumorigenesis. Research on the rapid selection of ligands based on the SELEX (systematic evolution of ligands by exponential enrichment) forms the basis for the development of high affinity and high specificity molecules, which can bind to surface determinants of tumour cells, like CEA. The oligonucleotides ligands generated in this technique are called aptamers. Aptamers can potentially find applications as therapeutic or diagnostic tools for many kind of diseases, like a tumor. Aptamers offer low immunogenicity, good tumour penetration, rapid uptake and fast systemic clearance, which favour their application as effective vehicles for radiotherapy. In addition aptamers can be labeled with different radioactive isotopes. The aim of this work was select aptamers binding to the CEA tumor marker. The aptamers are obtained through by SELEX, in which aptamers are selected from a library of random sequences of synthetic DNA by repetitive binding of the oligonucleotides to target molecule (CEA). Analyses of the secondary structure of the aptamers were determined using the m fold toll. Three aptamers were selected to binding assay with target cells. These aptamers were confirmed to have affinity and specific binding for T84 cell line (target cell), showed by confocal imaging. We are currently studying the potential efficacy of these aptamers as targeted radiopharmaceuticals, for use as imaging agents or therapeutic applications. The development of aptamers specific to CEA open new perspectives for colorectal cancer diagnosis and treatment. Acknowledgments: This investigation was supported by the Centro de Desenvolvimento da

  12. Assessment of diagnostic value of various tumors markers (CEA, CA199, CA50) for colorectal neoplasm with logistic regression and ROC curve

    International Nuclear Information System (INIS)

    Gu Ping; Huang Gang; Han Yuan

    2007-01-01

    Objective: To assess the diagnostic value of CEA, CA199 and CA50 for colorectal neoplasm by logistic regression and ROC curve. Methods: Serum CEA (with CLIA), CA199 (with ECLIA) and CA50 (with IRMA) levels were measured in 75 patients with colorectal cancer, 35 patients with benign colorectal disorders and 49 controls. The area under the ROC curve (AUC)s of CEA, CA199, CA50 from logistic regression results were compared. Results: In the cancer-benign disorder group, the AUC of CA50 was larger than the AUC of CA199. AUC of combined CEA, CA50 was largest: not only larger than any AUC of CEA, CA50, CA199 alone but also larger than the AUC of the combined three markers (0.875 vs 0.604). In cancer-control group, the AUC of combination of CEA, CA199 and CA50 was larger than any AUC of CEA, CA199 or CA50 alone. Both in the cancer-benign disorder group or cancer-control group, the AUC of CEA was larger than the AUC of CA199 or CA50. Conclusion: CEA is of definite value in the diagnosis of colorectal cancer. For differential diagnosis, the combination of CEA and CA50 can give more information, while the combination of three tumor markers is less helpful. As an advanced statistical method, logistic regression can improve the diagnostic sensitivity and specificity. (authors)

  13. Radioimmunoimaging of sup 131 I labeled CEA McAb in nude mice bearing human colonic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Peiyong, Li [Shanghai Second Medical Univ., SH (China). Ruijing Hospital; and others

    1990-02-01

    CEA McAb was purified by protein A-Sepharose 4B. ELISA had no obvious crossreaction with NCA and NFA. 1.85 {similar to} 3.7 MBq/10 {mu} g CEA McAb was injected into nude mice by intraperitoneal route. Radioimmunoimaging and biodistribution were performed at 5th, 6th, 7th and 8th day after injection. Results showed that satisfactory tumor imaging can be got after 5th day. On the 6th day, tumor and blood ratio was at its maximum, 301 +-0.1. There was significant difference between the CEA McAb and the IgG control group.

  14. Le contrôle de gestion des entreprises familiales : un contrôle non-financiarisé ?

    OpenAIRE

    Barbelivien , Dominique

    2016-01-01

    Nous examinons la tendance décrite dans la littérature quant à la financiarisation de la fonction de contrôle de gestion en nous appuyant sur le cas d’une entreprise de taille intermédiaire familiale. Nous constatons que le contrôle de gestion dans le cas étudié correspond à une rationalisation des décisions opérationnelles et développons les raisons qui peuvent expliquer la persistance d’un contrôle de gestion très opérationnel. Le contexte d’entreprise familiale dans laquelle il y a confusi...

  15. Diagnostic value of combined determination of serum and pleural effusion CEA, CYFRA21-1 and NSE levels in patients with malignancy

    International Nuclear Information System (INIS)

    Chen Xiaoxiao

    2008-01-01

    Objective: To study the clinical value of combined determination of serum and pleural effusion levels of CEA, CYFRA21-1 and NSE in patients with malignancy. Methods: Serum and pleural effusion CEA, CYFRA21-1 and NSE levels were measured with RIA in 40 patients with malignant and 32 patients with tuberculous pleural effusions. Results: The pleural effusion CEA, CYFRA21-1, NSE levels and pleural effusion serum levels ratio in malignant group were significantly higher than those in tuberculous group (P<0.01). The specificity of CEA (90%) was higher than those in that of CYFRA21-1 and NSE, and the sensitivity of CYFRA21-1 (83%) was higher than that of CEA and NSE. With combined detection of CEA, CYFRA21-1 and NSE, the sensitivity was 90% and the specificity was 89% for diagnosis of malignant pleural effusion. Conclusion: Combined determination of serum and pleural effusion CEA, CYFRA21-1 and NSE levels would be more sensitive for diagnosis of malignant pleural effusion. (authors)

  16. Numerical Platon: A unified linear equation solver interface by CEA for solving open foe scientific applications

    International Nuclear Information System (INIS)

    Secher, Bernard; Belliard, Michel; Calvin, Christophe

    2009-01-01

    This paper describes a tool called 'Numerical Platon' developed by the French Atomic Energy Commission (CEA). It provides a freely available (GNU LGPL license) interface for coupling scientific computing applications to various freeware linear solver libraries (essentially PETSc, SuperLU and HyPre), together with some proprietary CEA solvers, for high-performance computers that may be used in industrial software written in various programming languages. This tool was developed as part of considerable efforts by the CEA Nuclear Energy Division in the past years to promote massively parallel software and on-shelf parallel tools to help develop new generation simulation codes. After the presentation of the package architecture and the available algorithms, we show examples of how Numerical Platon is used in sequential and parallel CEA codes. Comparing with in-house solvers, the gain in terms of increases in computation capacities or in terms of parallel performances is notable, without considerable extra development cost

  17. Numerical Platon: A unified linear equation solver interface by CEA for solving open foe scientific applications

    Energy Technology Data Exchange (ETDEWEB)

    Secher, Bernard [French Atomic Energy Commission (CEA), Nuclear Energy Division (DEN) (France); CEA Saclay DM2S/SFME/LGLS, Bat. 454, F-91191 Gif-sur-Yvette Cedex (France)], E-mail: bsecher@cea.fr; Belliard, Michel [French Atomic Energy Commission (CEA), Nuclear Energy Division (DEN) (France); CEA Cadarache DER/SSTH/LMDL, Bat. 238, F-13108 Saint-Paul-lez-Durance Cedex (France); Calvin, Christophe [French Atomic Energy Commission (CEA), Nuclear Energy Division (DEN) (France); CEA Saclay DM2S/SERMA/LLPR, Bat. 470, F-91191 Gif-sur-Yvette Cedex (France)

    2009-01-15

    This paper describes a tool called 'Numerical Platon' developed by the French Atomic Energy Commission (CEA). It provides a freely available (GNU LGPL license) interface for coupling scientific computing applications to various freeware linear solver libraries (essentially PETSc, SuperLU and HyPre), together with some proprietary CEA solvers, for high-performance computers that may be used in industrial software written in various programming languages. This tool was developed as part of considerable efforts by the CEA Nuclear Energy Division in the past years to promote massively parallel software and on-shelf parallel tools to help develop new generation simulation codes. After the presentation of the package architecture and the available algorithms, we show examples of how Numerical Platon is used in sequential and parallel CEA codes. Comparing with in-house solvers, the gain in terms of increases in computation capacities or in terms of parallel performances is notable, without considerable extra development cost.

  18. Application of tumor markers SCC-Ag, CEA, and TPA in patients with cervical precancerous lesions.

    Science.gov (United States)

    Farzaneh, Farah; Shahghassempour, Shapour; Noshine, Bahram; Arab, Maliheh; Yaseri, Mehdi; Rafizadeh, Mitra; Alizadeh, Kamyab

    2014-01-01

    To determine the potential clinical utility of tumor markers CEA, TPA, and SCC-Ag for early detection of cervical precancerous lesions. A case-control study was carried out on 120 women (46 patients with histologically confirmed cervical precancerous lesions and 74 healthy controls). The significance of serum selected tumor markers in early detection of cervical intraepithelial neoplasia (CIN) were assessed. Of the case group, the rates of CIN I, II, III, was 69.6%, 23.9%, and 6.5%, respectively. According to the manufacturer's cut-off values of 2 ng/ml, 5 ng/ml, and 70 U/ml for SCC-Ag, CEA and TPA tests, in that order, SCC-Ag test had a sensitivity of 13%, but CEA and TPA tests could not distinguish between case and control groups. The diagnostic sensitivities were highest at cut-off values of 0.55 ng/ml for SCC-Ag, 2.6 ng/ ml for CEA, and 25.5 U/ml for TPA which were 93%, 61%, and 50%, respectively. However, the area under the receiver operating characteristic curve was the largest for SCC-Ag (0.95 vs. 0.61 and 0.60 for CEA and TPA, respectively). Moreover, there was a highly significant direct correlation between SCC-Ag concentration and the degree of cervical precancerous lesions (r=0.847, ptumor marker in Iranian patients with CIN and it needs to be more evaluated by studies with larger populationa.

  19. Application of VLLW management principles to the CEA research centers

    International Nuclear Information System (INIS)

    Guetat, P.

    1997-01-01

    This document describes the content of a CEA policy relating to very low level waste management elaborated in application of the waste management principles defined in France. The policy deals with very low level waste, subject to recycling, incineration or landfill disposal. It does not deal with reuse. The following principles are applicable to waste streams produced by CEA nuclear installations either during operating or dismantling activities. The policy deals only with very low level wastes (VLLW) (order of magnitude: <100 Bq/g for high energy emitters). It does not deal with low, intermediate or high level waste, which are either recycled or incinerated in nuclear industry or disposed of in the Aube surface disposal (CSA) or kept in intermediate storage, before geological disposal or any alternative final solution

  20. Novel flow cytometric analysis of the progress and route of internalization of a monoclonal anti-carcinoembryonic antigen (CEA) antibody.

    Science.gov (United States)

    Ford, C H; Tsaltas, G C; Osborne, P A; Addetia, K

    1996-03-01

    A flow cytometric method of studying the internalization of a monoclonal antibody (Mab) directed against carcinoembryonic antigen (CEA) has been compared with Western blotting, using three human colonic cancer cell lines which express varying amounts of the target antigen. Cell samples incubated for increasing time intervals with fluoresceinated or unlabelled Mab were analyzed using flow cytometry or polyacrylamide gel electrophoresis and Western blotting. SDS/PAGE analysis of cytosolic and membrane components of solubilized cells from the cell lines provided evidence of non-degraded internalized anti-CEA Mab throughout seven half hour intervals, starting at 5 min. Internalized anti-CEA was detected in the case of high CEA expressing cell lines (LS174T, SKCO1). Very similar results were obtained with an anti-fluorescein flow cytometric assay. Given that these two methods consistently provided comparable results, use of flow cytometry for the detection of internalized antibody is suggested as a rapid alternative to most currently used methods for assessing antibody internalization. The question of the endocytic route followed by CEA-anti-CEA complexes was addressed by using hypertonic medium to block clathrin mediated endocytosis.

  1. Development and characterisation of MCT detectors for space astrophysics at CEA

    Science.gov (United States)

    Boulade, O.; Baier, N.; Castelein, P.; Cervera, C.; Chorier, P.; Destefanis, G.; Fièque, B.; Gravrand, O.; Guellec, F.; Moreau, V.; Mulet, P.; Pinsard, F.; Zanatta, J.-P.

    2017-11-01

    The Laboratoire Electronique et Traitement de l'Information (LETI) of the Commissariat à l'Energie Atomique (CEA, Grenoble, France) has been involved in the development of infrared detectors based on HgCdTe (MCT) material for over 30 years, mainly for defence and security programs [1]. Once the building blocks are developed at LETI (MCT material process, diode technology, hybridization, …), the industrialization is performed at SOFRADIR (also in Grenoble, France) which also has its own R&D program [2]. In past years, LETI also developed infrared detectors for space astrophysics in the mid infrared range - the long wave detector of the ISOCAM camera onboard ISO - as well as in the far infrared range - the bolometer arrays of the Herschel/PACS photometer unit -, both instruments which were under the responsibility of the Astrophysics department of CEA (IRFU/SAp, Saclay, France). Nowadays, the infrared detectors used in space and ground based astronomical instruments all come from vendors in the US. For programmatic reasons - increase the number of available vendors, decrease the cost, mitigate possible export regulations, …- as well as political ones - spend european money in Europe -, the European Space Agency (ESA) defined two roadmaps (one in the NIR-SWIR range, one in the MWIR-LWIR range) that will eventually allow for the procurement of infrared detectors for space astrophysics within Europe. The French Space Agency (CNES) also started the same sort of roadmaps, as part of its contribution to the different space missions which involve delivery of instruments by French laboratories. It is important to note that some of the developments foreseen in these roadmaps also apply to Earth Observations. One of the main goal of the ESA and CNES roadmaps is to reduce the level of dark current in MCT devices at all wavelengths. The objective is to use the detectors at the highest temperature where the noise induced by the dark current stays compatible with the photon

  2. Radioimmunoscintigraphy with I-131-labelled anti-CEA monclonal antibody in colorectal cancer patients

    International Nuclear Information System (INIS)

    Xie Tianhao

    1988-01-01

    Twenty three colorectal carcinoma and two benign polyposis patients with operatively and histologically proven were studied by radioimmunoscintigraphy, using anti-CEA monoclonal antibodies (C14-17 and C50) radiolabeled with I-131 . Computer assisted processing for the subtraction of Tc-99m background radioactivity was used to enhance the detection and localization of tumor which is visualized by immune scintigraphy. The size of tumor and the ratios of tumor to nontumor (T/NT) are two very important factors for the external immunoscintigraphy. The antibody uptake and retention in tumor are likely to depend on the degree of vascularity and diffusion into the viable tumor mass. Based upon the obtained results, the sensitivity of the method (true-poditive) was 91%, its specificity (true-negative) was 100%. This study thus indicates that radioimmunoscintigraphy of cancer with radioactive anti-CEA monoclonal antibody is very uaeful in the diagnoses of patients with CEA-containing neoplasms

  3. NSE, CEA and SCC - a useful combination of tumor markers in lung cancer

    International Nuclear Information System (INIS)

    Fischbach, W.; Jany, B.

    1988-01-01

    The usefulness of neuronspecific enolase (NSE), CEA, and of the tumor associated antigen SSC was investigated in 61 patients with histologically proven lung cancer (small cell lung cancer n=25, adenocarcinoma n=14, squamous cell carcinoma n=18 and large cell carcinoma n=4). The sensitivity of NSE was 93.3% in small cell lung cancer (SCLC), whereas in adeno- and squamous cell carcinoma only 8 or 13%, resp., elevated serum NSE were found. CEA was the most sensitive marker for adenocarcinoma (58.3%). Contrary to NSE, however, CEA does not allow any conclusions concerning differential diagnosis as pathological serum concentrations were also observed in 46.6% both in small cell lung cancer and in squamous cell carcinoma. SCC demonstrated a sensitivity of 53% in squamous cell carcinoma. Elevated serum levels were also found in adenocarcinoma (41.6%), but never in small lung cancer. For all three markers tested, high serum concentrations were predominantly present in patients with advanced disease state. (orig.) [de

  4. Decommissioning works are going on at Fontenay-aux-roses CEA center

    International Nuclear Information System (INIS)

    Anon.

    2003-01-01

    The CEA center of Fontenay-aux-roses is pursuing the dismantling operations of its nuclear installations. In 2003 120 glove boxes of the plutonium chemistry laboratory were disassembled and moved to the Cadarache CEA center. Hot cells from the Castor, Cyrano and Petrus lines are currently undergoing decontamination operations before being dismantled. As for the processing station of liquid effluents, the cutting works of the incinerator of low-level radioactive wastes and of the tanks began in 2003 and are expected to be over by end 2004. The Triton research reactor was decommissioned in 1982 and dismantling works on its hot cell and on its pool began at the end of 2003. (A.C.)

  5. Dispersion of Radionuclides and Exposure Assessment in Urban Environments: A Joint CEA and LLNL Report

    International Nuclear Information System (INIS)

    Glascoe, Lee; Gowardhan, Akshay; Lennox, Kristin; Simpson, Matthew; Yu, Kristen; Armand, Patrick; Duchenne, Christophe; Mariotte, Frederic; Pectorin, Xavier

    2014-01-01

    In the interest of promoting the international exchange of technical expertise, the US Department of Energy’s Office of Emergency Operations (NA-40) and the French Commissariat à l'Energie Atomique et aux énergies alternatives (CEA) requested that the National Atmospheric Release Advisory Center (NARAC) of Lawrence Livermore National Laboratory (LLNL) in Livermore, California host a joint table top exercise with experts in emergency management and atmospheric transport modeling. In this table top exercise, LLNL and CEA compared each other's flow and dispersion models. The goal of the comparison is to facilitate the exchange of knowledge, capabilities, and practices, and to demonstrate the utility of modeling dispersal at different levels of computational fidelity. Two modeling approaches were examined, a regional scale modeling approach, appropriate for simple terrain and/or very large releases, and an urban scale modeling approach, appropriate for small releases in a city environment. This report is a summary of LLNL and CEA modeling efforts from this exercise. Two different types of LLNL and CEA models were employed in the analysis: urban-scale models (Aeolus CFD at LLNL/NARAC and Parallel- Micro-SWIFT-SPRAY, PMSS, at CEA) for analysis of a 5,000 Ci radiological release and Lagrangian Particle Dispersion Models (LODI at LLNL/NARAC and PSPRAY at CEA) for analysis of a much larger (500,000 Ci) regional radiological release. Two densely-populated urban locations were chosen: Chicago with its high-rise skyline and gridded street network and Paris with its more consistent, lower building height and complex unaligned street network. Each location was considered under early summer daytime and nighttime conditions. Different levels of fidelity were chosen for each scale: (1) lower fidelity mass-consistent diagnostic, intermediate fidelity Navier-Stokes RANS models, and higher fidelity Navier-Stokes LES for urban-scale analysis, and (2) lower-fidelity single

  6. Dispersion of Radionuclides and Exposure Assessment in Urban Environments: A Joint CEA and LLNL Report

    Energy Technology Data Exchange (ETDEWEB)

    Glascoe, Lee [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gowardhan, Akshay [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Lennox, Kristin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Simpson, Matthew [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Yu, Kristen [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Armand, Patrick [Alternative Energies and Atomic Energy Commission (CEA), Paris (France); Duchenne, Christophe [Alternative Energies and Atomic Energy Commission (CEA), Paris (France); Mariotte, Frederic [Alternative Energies and Atomic Energy Commission (CEA), Paris (France); Pectorin, Xavier [Alternative Energies and Atomic Energy Commission (CEA), Paris (France)

    2014-12-19

    In the interest of promoting the international exchange of technical expertise, the US Department of Energy’s Office of Emergency Operations (NA-40) and the French Commissariat à l'Energie Atomique et aux énergies alternatives (CEA) requested that the National Atmospheric Release Advisory Center (NARAC) of Lawrence Livermore National Laboratory (LLNL) in Livermore, California host a joint table top exercise with experts in emergency management and atmospheric transport modeling. In this table top exercise, LLNL and CEA compared each other’s flow and dispersion models. The goal of the comparison is to facilitate the exchange of knowledge, capabilities, and practices, and to demonstrate the utility of modeling dispersal at different levels of computational fidelity. Two modeling approaches were examined, a regional scale modeling approach, appropriate for simple terrain and/or very large releases, and an urban scale modeling approach, appropriate for small releases in a city environment. This report is a summary of LLNL and CEA modeling efforts from this exercise. Two different types of LLNL and CEA models were employed in the analysis: urban-scale models (Aeolus CFD at LLNL/NARAC and Parallel- Micro-SWIFT-SPRAY, PMSS, at CEA) for analysis of a 5,000 Ci radiological release and Lagrangian Particle Dispersion Models (LODI at LLNL/NARAC and PSPRAY at CEA) for analysis of a much larger (500,000 Ci) regional radiological release. Two densely-populated urban locations were chosen: Chicago with its high-rise skyline and gridded street network and Paris with its more consistent, lower building height and complex unaligned street network. Each location was considered under early summer daytime and nighttime conditions. Different levels of fidelity were chosen for each scale: (1) lower fidelity mass-consistent diagnostic, intermediate fidelity Navier-Stokes RANS models, and higher fidelity Navier-Stokes LES for urban-scale analysis, and (2) lower-fidelity single

  7. Management and storage of spent fuel from CEA research reactors

    International Nuclear Information System (INIS)

    Merchie, F.

    1996-01-01

    CEA research reactors and their interim spent fuel storage facilities are described. Long-term solutions for spent fuel storage problems, involving wet storage at PEGASE or dry storage at CASCAD, are outlined in some detail. (author)

  8. Radioimmunoimaging of ovarian cancer with 131I labelled CEA monoclonal antibody

    International Nuclear Information System (INIS)

    Hu Likuan; Li Zhen; Huo Zhenguo; Jiang Sen; Jia Shiquan

    2001-01-01

    Objective: To investigate radioimmunoimaging with 131 I labelled CEA McAb and its value in diagnosis and treatment of ovarian cancer. Methods: CEA McAb was labelled with 131 I by standard chloramine T procedure. The radiolabeled McAb was given intravenously to the patients. The scintigraphy was performed at different time. Results: In 105 patients with histopathology proved ovarian cancers, for 96 patients the lesions were well located with RII (true positives), for the remaining 9 patients, the results were false negative. 22/23 cases with RII diagnosed benign ovarian tumors were proved to be true negative by surgical pathology in RII. Of 96 ovarian cancers 87 were stratified into identical stages by surgical pathology all RII. 141/151 metastatic tumors were found in RII and the positive rate was as high as 93.4%. The smallest tumor defected by RII was of 1 cm in diameter. Conclusions: RII is as good as ultrasonography and CT in distinguishing benignancy and malignancy. The location, size and number of the lesions can also be determined with RII. RII of ovarian cancer with 131 I-CEA McAb is valuable and helpful in early detection of ovarian cancer. It is also helpful for clinical staging, treatment programing and prognosticating

  9. The CEA and the alternative energies. Press tour 25 and 26 november 1999

    International Nuclear Information System (INIS)

    Carola, G.; Ngo, Ch.; Mermilliod, N.; Serre-Combe, P.; Sanglan, P.; De La Graviere, M.; Dieudonne, O.; Malbranche, Ph.

    1999-11-01

    In the framework of the public information on the CEA center of Cadarache and Grenoble, a presentation of the researches concerning the alternative energies is proposed. The Cea is commissioned by the Public Authorities, to keep the nuclear option open and for the long-dated, to develop renewable energies. In this domain researches on fuel cells and photovoltaic solar energy are performed. The principle and the applications of the fuel cell and the photovoltaic are recalled to introduce the research programs and the partners. (A.L.B.)

  10. R and D on Transmutation at CEA: Recent Results

    International Nuclear Information System (INIS)

    Royet, V.; Delahaye, T.; Lebreton, F.; Picart, S.; Caisso, M.; Gauthe, A.; Ode, D.; Tronche, E.; Bayle, J.P; Warin, D.; Bejaoui, S.; Delage, F.

    2015-01-01

    In the field of minor actinide transmutation in future Generation IV SFR reactor, CEA investigates in priority the recycling of Americium (Am) in the radial blankets located in the outer core area (AmBB: Americium Bearing Blankets). This paper gives an overview of the recent outcomes of the R and D programme carried out at CEA in the different fields of research: from powder elaboration to experimental irradiation. Concerning the powder elaboration, several batches have been produced by the oxalic co-conversion route as well as by the Calcined Resin Microsphere Pelletizing. Different tests have been then performed for the fabrication of pellets according to the current specifications of AmBB. For these two processes, different additional developments of innovative technologies have been achieved well adapted with the processes constraints and hot cell operating. Information on irradiation programmes (MARIOS in HFR and ongoing DIAMINO in Osiris) are presented. The next steps of the programme will then be tackled. (authors)

  11. Characterization and consequences from CEA nuclear fuel cycle facilities effluents releases - 1995 up to 2007 period

    International Nuclear Information System (INIS)

    Ferreira, Nelson Luiz Dias; Fonseca, Lizandra Pereira de Souza

    2009-01-01

    Discharges to the environment of airborne and/or liquid radioactive effluents from the normal operation of nuclear facilities can become a potential source of radiation exposure to humans. The highest exposed members of the public are defined as the critical group. The requirements for the control and monitoring of radioactive discharges to the environment and the degree of environmental monitoring required are linked to the assessed critical group dose. The assessed dose can be compared to dose constraint, which is a fraction of the annual effective dose to members of the public, as well as the level of exemption specified by the National Commission for Nuclear Energy (CNEN). Effluents releases from the Centro Experimental Aramar (CEA) facilities are registered and described at CEA Effluent Report, semestrally sent to CNEN. Basically, that report provides information related to the type and the quantity of chemical and radioactive substances released to the environment due the routine operation of CEA nuclear fuel cycle facilities (LEI - Isotopic Enrichment Laboratory, USIDE - Pilot Plant for Industrial Verification of Uranium Enrichment and LABMAT - Nuclear Materials Laboratory). CEA Annual Effluent Report includes assessment of the annual effective doses for members of the critical group for the CEA site. This work presents the characterization of the radioactive release source terms and a historical of the critical group annual doses from 1995 up to 2007. (author)

  12. Metastatic prostate cancer with elevated serum levels of CEA and CA19-9

    Directory of Open Access Journals (Sweden)

    Guang-Dar Juang

    2014-03-01

    Full Text Available Prostate-specific antigen (PSA is well known as a specific tumor marker for prostate cancer, but carcinoembryonic antigen (CEA- and carbohydrate antigen 19-9 (CA19-9-elevating adenocarcinomas originating in the prostate gland are rare. We report a case of metastatic adenocarcinoma of the prostate gland with a high serum level of CEA and CA19-9 in a 78-year-old man in whom prostate cancer (T3N1M1 had been diagnosed 2 years ago and who was treated with androgen deprivation therapy. He visited the emergency department because of a loss of appetite and abdominal pain. The serum CEA and CA19-9 levels were increased to 218.9 ng/mL (normal, <5 ng/mL and 212 ng/mL (normal, <27 ng/mL, respectively. The serum PSA level was slightly elevated (4.41 ng/mL. Computed tomography demonstrated multiple liver metastases, para-aortic lymph node enlargement, and lung metastases. A liver biopsy was performed and the specimen showed high-grade adenocarcinoma with focal positive staining for PSA. Despite chemotherapy with docetaxel, the patient died 3 months after treatment. Based on this case and a review of the literature, an aggressive variant of prostatic carcinoma with a high serum level of CEA and CA19-9 and a low PSA level was shown to progress rapidly with a poor prognosis.

  13. Prognostic significance of preoperative serum CA125, CA19-9 and CEA in gastric carcinoma

    Science.gov (United States)

    Wang, Wei; Chen, Xiao-Long; Zhao, Shen-Yu; Xu, Yu-Hui; Zhang, Wei-Han; Liu, Kai; Chen, Xin-Zu; Yang, Kun; Zhang, Bo; Chen, Zhi-Xin; Chen, Jia-Ping; Zhou, Zong-Guang; Hu, Jian-Kun

    2016-01-01

    The prognostic significance of preoperative serum CA125, CA19-9 and CEA in gastric carcinoma (GC) has been widely reported and is still under debate. Here, we evaluated the prognostic significance of preoperative serum CA125, CA19-9 and CEA in patients with GC. 1692 patients with GC who underwent gastrectomy were divided into the training (from January 2005 to December 2011, n = 1024) and the validation (from January 2012 to December 2013, n = 668) cohorts. Positive groups of CA125 (> 13.72 U/ml), CA19-9 (> 23.36 U/ml) and CEA (> 4.28 ng/ml) were significantly associated with more advanced clinicopathological traits and worse outcomes than that of negative groups (all P tumor size (P tumor markers (NPTM) were more accurate in prognostic prediction than TNM stage alone. Our findings suggested that elevated preoperative serum CA125, CA19-9 and CEA were associated with more advanced clinicopathological traits and less favorable outcomes. In addition, CA125 as an independent prognostic factor should be further investigated. Nomogram based on NPTM could accurately predict the prognosis of GC patients. PMID:27097114

  14. CEA programme on gas cooled reactors

    International Nuclear Information System (INIS)

    Carre, F.; Fiorini, G.L.; Chapelot, Ph.; Gauthier, J.C.

    2002-01-01

    Future nuclear energy systems studies conducted by the CEA aim at investigating and developing promising technologies for future reactors, fuels and fuel cycles, for nuclear power to play a major part in sustainable energy policies. Reactors and fuel cycles are considered as integral parts of a nuclear system to be optimised as a whole. Major goals assigned to future nuclear energy systems are the following: reinforced economic competitiveness with other electricity generation means, with a special emphasis on reducing the investment cost; enhanced reliability and safety, through an improved management of reactor operation in normal and abnormal plant conditions; minimum production of long lived radioactive waste; resource saving through an effective and flexible use of the available resources of fissile and fertile materials; enhanced resistance to proliferation risks. The three latter goals are essential for the sustainability of nuclear energy in the long term. Additional considerations such as the potentialities for other applications than electricity generation (co-generation, production of hydrogen, sea water desalination) take on an increasing importance. Sustainability goals call for fast neutron spectra (to transmute nuclear waste and to breed fertile fuel) and for recycling actinides from the spent fuel (plutonium and minor actinides). New applications and economic competitiveness call for high temperature technologies (850 deg C), that afford high conversion efficiencies and hence less radioactive waste production and discharged heat. These orientations call for breakthroughs beyond light water reactors. Therefore, as a result of a screening review of candidate technologies, the CEA has selected an innovative concept of high temperature gas cooled reactor with a fast neutron spectrum, robust refractory fuel, direct conversion with a gas turbine, and integrated on-site fuel cycle as a promising system for a sustainable energy development. This objective

  15. Annual report of the Association EURATOM-Cea 2005 (full report)

    International Nuclear Information System (INIS)

    Salmon, Th.; Le Vagueres, F.

    2005-01-01

    This annual report summarizes activities performed by the EURATOM-Cea association in 2005. The activities carried out in the field 'physics integration' are mainly linked to the ion cyclotron range of frequency antenna development and to the development of diagnostic components. The vacuum vessel studies have mainly focused at welding techniques and at qualification of inspection methods along the vacuum vessel inter-sector weld. On the plasma facing component side investigations have been performed on material knowledge (CuCrZr creep-fatigue studies, neutron effects on material properties of CFC, development and optimisation of Be/CuCrZr joining techniques and studies dedicated to the divertor. In the field 'magnets', EURATOM-Cea association has devoted a major part of its effort to the studies of advanced Nb 3 Sn strands for the toroidal field coil, and the first full size conductor sample was manufactured. Within the frame of Test Blanket Module (TBM), activities mainly concerned the improvement and completion of the TBM engineering design. Within the frame of the Helium Cooled Pebble Bed concept programmes, studies about the development of Li 2 TiO 3 pebbles are on going. The main objective of 2005 which was to improve the shape of Li 2 TiO 3 pebbles has been successfully achieved. EURATOM-Cea maintained significant involvement in the development of structural materials for a fusion reactor. A strong effort has been made on a program of laser detritiation associated with remote handling. (A.C.)

  16. Clinical significance of determination of changes of serum CEA, NSE, CA19-9 and VEGF levels in patients with lung cancer

    International Nuclear Information System (INIS)

    Gu Yan; Wang Yuyi

    2009-01-01

    Objective: To explore the clinical significance of changes of serum CEA, NSE, CA19-9 and VEGF levels in patients with lung cancer. Methods: Serum CEA, NES, CA19-9 (with RIA) and VEGF (with ELISA) levels were detected in 31 patients with lung cancer and 35 controls. Results: The levels of serum CEA, NSE, CA19-9 and VEGF were significantly higher in the patients than those in controls (P<0.01). Serum CEA, NSE, CA19-9 levels were positively correlated with the VEGF levels (r=0.6218, 0.6101, 0.6317, P<0.01). Conclusion: Serum CEA, NSE, CA19-9 and VEGF levels were closely related to the diseases process of lung cancer and were of prognostic values. (authors)

  17. CEA-producing urothelial cell carcinoma with metastasis presenting as a rectal adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Ming-Hsin Yang

    2012-11-01

    Full Text Available This is a case study of a 61-year-old male who presented with difficult defecation for 1 month. A circumferential submucosal rectal tumor was noted on a digital rectal examination and colonoscopy. Laboratory examination revealed high serum levels of carcinoembryonic antigen (CEA; 43.75 ng/mL and carbohydrate antigen 19-9 (CA19-9; 11,790 U/mL. In addition, tumor biopsies revealed a poorly differentiated adenocarcinoma of the rectum with intact mucosa. The patient had history of advanced stage-T2 urothelial cell carcinoma of bladder, which had been downstaged to T0 by neoadjuvant chemotherapy followed by radical cystectomy 1 year prior. After investigating the initial bladder tumor specimens, a small portion of the tumor with high CEA expression comparable to the submucosal rectal tumor was found. The size of the tumor was reduced and the levels of the tumor markers decreased after administering FOLFIRI chemotherapy targeted at the adenocarcinoma. Although neoadjuvant chemotherapy may have a selective pressure to eliminate most urothelial cell carcinoma, physicians should be aware that it can lead to rectal metastasis via CEA-producing components.

  18. CEA assay in the follow-up of patients with bowel cancer and breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Vassilakos, P J; Glaros, D C; Sdougou-Christacopoulou, J; Dermentzoglou, F; Samaras, V [Democritus Nuclear Research Center, Athens (Greece)

    1978-01-01

    The findings gave high CEA values only in 33.3% of patients from the group with bowel cancer and in 30.7% from that with breast cancer which confirms the earlier suggestion that the CEA is not selective enough to identify the early stage of the disease. The test can be valuable as a prognostic marker capable of suggesting the succesful response to therapy and can give evidence of the recurrence of the disease in early diagnosis.

  19. Fission product releases at severe LWR accident conditions: ORNL/CEA measurements versus calculations

    Energy Technology Data Exchange (ETDEWEB)

    Andre, B.; Ducros, G.; Leveque, J.P. [CEA Centre d`Etudes de Grenoble, 38 (France). Dept. de Thermohydraulique et de Physique; Osborne, M.F.; Lorenz, R.A. [Oak Ridge National Lab., TN (United States); Maro, D. [CEA Centre d`Etudes de Fontenay-aux-Roses, 92 (France). Dept. de Protection de l`Environnement et des Installations

    1995-12-31

    Experimental programs in the United States and France have followed similar paths in supplying much of the data needed to analyze severe accidents. Both the HI/VI program, conducted at the Oak Ridge National Laboratory (ORNL) under the sponsorship of the U. S. Nuclear Regulatory Commission (NRC), and the HEVA/VERCORS program, supported by IPSN-Commissariat a l`Energie Atomique (CEA) and carried out at the Centre d`Etudes Nucleaires de Grenoble, have studied fission product release from light water reactor (LWR) fuel samples during test sequences representative of severe accidents. Recognizing that more accurate data, i.e., a better defined source term, could reduce the safety margins included in the rather conservative source terms originating from WASH-1400, the primary objective of these programs has been to improve the data base concerning fission product release and behavior at high temperatures. To facilitate the comparison, a model based on fission product diffusion mechanisms that was developed at ORNL and adapted with CEA experimental data is proposed. This CEA model is compared with the ORNL experimental data in a blind test. The two experimental programs used similar techniques in out-of-pile studies. Highly irradiated fuel samples were heated in radiofrequency induction furnaces to very high temperatures (up to 2700 K at ORNL and 2750 K at CEA) in oxidizing (H{sub 2}O), reducing (H{sub 2}) or mixed (H{sub 2}O+H{sub 2}) environments. The experimental parameters, which were chosen from calculated accident scenarios, did not duplicate specific accidents, but rather emphasized careful control of test conditions to facilitate extrapolation of the results to a wide variety of accident situations. This paper presents a broad and consistent database from ORNL and CEA release results obtained independently since the early 1980`S. A comparison of CORSOR and CORSOR Booth calculations, currently used in safety analysis, and the experimental results is presented and

  20. Carcinoembryonic antigen (CEA): practicability and quality of the radioimmunoassay: value for diagnosis and follow-up study

    Energy Technology Data Exchange (ETDEWEB)

    Neumeier, D [Univ., Munich; Wolter, B; Fateh-Moghadam, A; Knedel, M; Werber, K; Scholze, P

    1976-04-01

    The course of the carcinoembryonic antigen in male patients suffering from gastro-enteric tumors and in female patients with mastocarcinoma and pancreatic carcinoma was examined with the help of RIA. The practicability and the quality of the determination methods and their results with regard to the CEA-values in diagnostics and case control were tested. The results obtained show that the importance of the CEA-determinations lie in the case control of malignant tumors, since a successful therapy reduces the increased values and a recrudescence indicates recurrence of the tumor or formation of metastases. Especially in treatment of patients with malignant gastro-enteric tumors, the CEA-level should be determined before beginning with therapy.

  1. Radioactivity and radioprotection: the every day life in a nuclear installation. Press tour at CEA/GRENOBLE 18 november 1999; Radioactivite et radioprotection: la vie quotidienne dans une installation nucleaire. Voyage de presse au Centre CEA/CADARACHE 18 novembre 1999

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    In the framework of the public information, this paper gives a general information on the radioactivity and the radioprotection at the CEA/Cadarache center. A first part is devoted to a presentation of the radioactivity with definitions and radiation effects on the human being and the environment. An other part presents the radioprotection activities and regulations. The last part deals with specific activities of the CEA/Cadarache: the CASCAD installations for spent fuels storage, the LECA Laboratory for the Examination of Active Fuels and a dismantling installation for big irradiated objects. Historical aspects of the CEA/Cadarache are also provided. (A.L.B.)

  2. The dismantling of nuclear installations in the Grenoble CEA centre - Press book 2013

    International Nuclear Information System (INIS)

    Laveissiere, Stephane; Coronini, Vincent

    2013-01-01

    After having outlined the importance of the project for the Grenoble CEA centre, this document presents the objectives, issues and challenges of dismantling activities performed on various nuclear installations located in the CEA centre of Grenoble. Objectives are presented in terms of agenda, predicted production of radioactive wastes, budget, personnel and steering committee. The various nuclear installations are presented: experimental reactors (Melusine, Siloe, Siloette), LAMA (laboratory of analysis of active materials), STED (station for the treatment of effluents and wastes). The safety and protection of workers is addressed in terms of protection and monitoring measures, and of exposure to radiations. The next part deals with the monitoring of the environment (actors, history of control of the centre's releases, control points, releases, atmosphere monitoring, and hydrological monitoring). A second part presents the global strategy of the CEA for its activities of sanitation and nuclear dismantling: present operations, dismantling activities in Fontenay-aux-Roses and in Marcoule, economic organization, contribution of advanced technology in radiological measurement and control, simulation and modelling, decontamination techniques, cutting operations, and remotely controlled operations

  3. New measurements in plutonium L X ray emission spectrum using an electron probe micro-analyser; Nouvelles mesures dans le spectre d'emission L du plutonium au moyen d'un micro analyseur a sonde electronique

    Energy Technology Data Exchange (ETDEWEB)

    Bobin, J L; Despres, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1966-07-01

    Further studies by means of an electron-probe micro-analyser, allowed report CEA-R--1798 authors to set up a larger plutonium X ray spectrum table. Measurements of plutonium L{sub II} and L{sub III} levels excitation potentials have also been achieved. Some remarks about apparatus performance data (such as spectrograph sensibility, resolving power and accuracy) will be found in the appendix. (authors) [French] Poursuivant les etudes exposees dans le rapport CEA-R--1798, les auteurs ont pu dresser un tableau plus etendu du spectre L du plutonium, au moyen du micro-analyseur a sonde electronique. Ils ont egalement effectue des mesures de potentiel d'excitation des niveaux L{sub II} et L{sub III} du plutonium. On trouvera en annexe quelques notes sur les constantes d'appareillage (sensibilite, pouvoir de resolution et precision des spectrographes). (auteurs)

  4. Elaboration of an alpha-numeric classification for file of matters of the documentation service of the CEA

    International Nuclear Information System (INIS)

    Braffort, P.

    1953-01-01

    We give the principles of a classification of matters to square basis, suiting the needs of the Service, of Documentation of the C.E.A. We present the detail of the categories in the order of the 'columns', likewise the big scientific subdivisions at the CEA. (authors) [fr

  5. Dexamethasone minimizes the risk of cranial nerve injury during CEA.

    Science.gov (United States)

    Regina, Guido; Angiletta, Domenico; Impedovo, Giovanni; De Robertis, Giovanni; Fiorella, Marialuisa; Carratu', Maria Rosaria

    2009-01-01

    The incidence of cranial and cervical nerve injury during carotid endarterectomy (CEA) ranges from less than 7.6% to more than 50%. Lesions are mainly due to surgical maneuvers such as traction, compression, tissue electrocoagulation, clamping, and extensive dissections. The use of dexamethasone (DEX) and its beneficial effects in spinal cord injuries have already been described. We investigated whether DEX could also be beneficial to minimize the incidence of cranial and cervical nerve injury during CEA. To evaluate whether dexamethasone is able to reduce the incidence of cranial nerve injuries. From March 1999 through April 2006, 1126 patients undergoing CEA because of high-grade carotid stenosis were enrolled and randomized by predetermined randomization tables into two groups. The first group, "A", included 586 patients that all received an intravenous administration of dexamethasone following a therapeutic scheme. The second group, "B", included 540 control subjects that received the standard pre- and postoperative therapy. All patients were submitted to a deep cervical plexus block, eversion carotid endarterectomy, and selective shunting. Three days after the operation, an independent neurologist and otorhinolaryngologist evaluated the presence of cranial nerve deficits. All patients (group A and group B) showing nerve injuries continued the treatment (8 mg of dexamethasone once in the morning) for 7 days and were re-evaluated after 2 weeks, 30 days, and every 3 months for 1 year. Recovery time took from 2 weeks to 12 months, with a mean time of 3.6 months. The chi(2) test was used to compare the two groups and to check for statistical significance. The incidence of cranial nerve dysfunction was higher in group B and the statistical analysis showed a significant effect of dexamethasone in preventing the neurological damage (P = .0081). The incidence of temporary lesions was lower in group A and the chi(2) test yielded a P value of .006. No statistically

  6. Combination of preoperative NLR, PLR and CEA could increase the diagnostic efficacy for I-III stage CRC.

    Science.gov (United States)

    Peng, Hong-Xin; Yang, Lin; He, Bang-Shun; Pan, Yu-Qin; Ying, Hou-Qun; Sun, Hui-Ling; Lin, Kang; Hu, Xiu-Xiu; Xu, Tao; Wang, Shu-Kui

    2017-09-01

    Inflammation plays an important role in the development and progression of CRC. The members of inflammatory biomarkers, preoperative NLR and PLR, have been proved by numerous studies to be promising prognostic biomarkers for CRC. However, the diagnostic value of the two biomarkers in CRC remains unknown, and no study reported the combined diagnostic efficacy of NLR, PLR and CEA. Five hundred and fifty-nine patients with I-III stage CRC undergoing surgical resection and 559 gender- and age-matched healthy controls were enrolled in this retrospective study. NLR and PLR were calculated from preoperative peripheral blood cell count detected using white blood cell five classification by Sysmex XT-1800i Automated Hematology System and serum CEA were measured by electrochemiluminescence by ELECSYS 2010. The diagnostic performance of NLR, PLR and CEA for CRC was evaluated by ROC curve. Levels of NLR and PLR in the cases were significantly higher than them in the healthy controls. ROC curves comparison analyses showed that the diagnostic efficacy of NLR (AUC=.755, 95%CI=.728-.780) alone for CRC was significantly higher than PLR (AUC=.723, 95%CI=.696-.749, P=.037) and CEA (AUC=.690, 95%CI=.662-.717, P=.002) alone. In addition, the diagnostic efficacy of the combination of NLR, PLR and CEA(AUC=.831, 95%CI=.807-.852)for CRC was not only significantly higher than NLR alone but also higher than any combinations of the two of these three biomarkers (PCRC diagnostic biomarker, even for early stage CRC, and the combination of NLR, PLR and CEA could significantly improve the diagnostic efficacy. © 2016 Wiley Periodicals, Inc.

  7. Le pompage optique naturel dans le milieu astrophysique

    Science.gov (United States)

    Pecker, J.-C.

    The title of this lecture abstracts only a part of it : the importance in astrophysics of the study of non-LTE situations has become considerable, as well in the stellar atmospheres as, still more, in the study of fortuitous coincidences as a mechanism of formation of emission line nebular spectra, or of molecular interstellar « masers ». Another part of this talk underlines the role of Kastler in his time, and describes his warm personality through his public reactions in front of the nuclear armement, of the Viet-Nam and Algerian wars, of the problems of political refugees... Kastler was a great scientist ; he was also a courageous humanist. 1976 : Les accords nucléaires du Brésil : allocution d'ouverture (19 mars). Colloque sur le sujet ci-dessus. 1976 : La promotion de la culture dans le nouvel ordre économique international, allocution à l'occasion d'une table ronde sur ce thème par l'UNESCO (23-27 juin 1976) ; « Sciences et Techniques », octobre 1976. 1979 : La bête immonde (avec J.-C. Pecker), « Le Matin », 20 mars. 1979 : Appel à nos ministres (avec J.-C. Pecker), « Le Monde », 13 décembre. 1979 : Le flou, le ténébreux, l'irrationnel (avec J.-C. Pecker), « Le Monde », 14 septembre. 1980 : Education à la paix, Préface, in : Publ. UNESCO. 1981 : Le vrai danger, « Le Monde », 6 août 1981. 1982 : Nucléaire civil et militaire, « Le Monde », 1er juin 1982. 1982 : Les scientifiques face à la perspective d'holocauste nucléaire (texte inédit). Le titre de cette communication en résume seulement une partie : l'importance prise en astrophysique par l'analyse des situations hors ETL est devenue considérable, qu'il s'agisse des atmosphères stellaires, ou plus encore, des coïncidences fortuites de la formation des spectres d'émission nébulaires, ou des « masers » moléculaires interstellaires. Une autre partie de cet exposé souligne lele de Kastler dans son époque, et décrit sa personnalité généreuse à travers ses r

  8. Updated on effluents releases of the CEA nuclear fuel cycle facilities - 1995 to 2010 period

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Nelson Luiz Dias [Centro Tecnologico da Marinha em Sao Paulo (CTMSP) Sao Paulo, SP (Brazil)

    2011-07-01

    The environmental impact assessment of the Centro Experimental Aramar (CEA) facilities has been presented in a former work, based on the measured effluent releases data, for the period from 1995 to 2007. This work shows the update up to 2010. The effluents releases to the environment result from the routine operation of CEA nuclear fuel cycle facilities (LEI - Isotopic Enrichment Laboratory, USIDE - Pilot Plant for Industrial Verification of Uranium Enrichment and LABMAT - Nuclear Materials Laboratory). Basically, this work presents the radioactive release source terms, as described at the CEA Effluent Report sent to the National Commission for Nuclear Energy (CNEN) each semester, and a historical assessment of the critical group annual doses from 1995 up to 2010. The assessed doses are compared to the maximum dose constraint as well as to the exemption level specified by CNEN. (author)

  9. Updated on effluents releases of the CEA nuclear fuel cycle facilities - 1995 to 2010 period

    International Nuclear Information System (INIS)

    Ferreira, Nelson Luiz Dias

    2011-01-01

    The environmental impact assessment of the Centro Experimental Aramar (CEA) facilities has been presented in a former work, based on the measured effluent releases data, for the period from 1995 to 2007. This work shows the update up to 2010. The effluents releases to the environment result from the routine operation of CEA nuclear fuel cycle facilities (LEI - Isotopic Enrichment Laboratory, USIDE - Pilot Plant for Industrial Verification of Uranium Enrichment and LABMAT - Nuclear Materials Laboratory). Basically, this work presents the radioactive release source terms, as described at the CEA Effluent Report sent to the National Commission for Nuclear Energy (CNEN) each semester, and a historical assessment of the critical group annual doses from 1995 up to 2010. The assessed doses are compared to the maximum dose constraint as well as to the exemption level specified by CNEN. (author)

  10. Dismantling at the CEA's Nuclear Energy Division: strategy and programmes

    International Nuclear Information System (INIS)

    Lecomte, C.; Prunele, D. de; Rozain, J.P.; Nokhamzon, J.G.; Tallec, M.

    2008-01-01

    The CEA's Nuclear Energy Division (DEN) nuclear facilities currently include seventeen reactors and thirty six other miscellaneous facilities, particularly laboratories, fuel processing units and facilities specific to waste management. Some of these are currently being dismantled or must be dismantled soon so that the DEN, the Nuclear Energy Division, can construct new equipment and thus have available a range of R and D facilities in line with the issues of the nuclear industry of the future. At CEA, the first nuclear facility dismantling operations go back several dozen years and involve numerous and varied facilities. The first operations of any significance took place in the 1960's and 1970's and covered, for example, the first plutonium plant at Fontenay-aux-Roses (total dismantling) and small research reactors or critical models - CESAR and PEGGY at Cadarache and MINERVE at Fontenay-aux Roses (civil engineering cleaned up and kept). At La Hague, the dismantling of AT1, a pilot workshop used by the CEA during the 1970's to process irradiated fuels from fast neutron reactors, was completed in March 2001 (IAEA former stage 3, excluding civil engineering demolition). On the other hand, during this period of first dismantling, the intermediate-sized reactors (G1, Rapsodie) were only partially dismantled after shut down, mainly due to the lack of graphite and sodium waste management routes at the time. About twenty facilities were thus dealt with up to 2001, in other words about half of all the nuclear facilities shut down permanently before this date. (authors)

  11. Extraction of High Charge Electron Bunch from the ELSA RF Injector Comparison Between Simulation and Experiment

    CERN Document Server

    Lemaire, J; Binet, A; Lagniel, J M; Le Flanchec, V; Pichoff, N

    2004-01-01

    A new scheme based on a photoinjector and a RF linear accelerator operating at 352 MHz has been recently proposed as a versatile radiographic facility. Beam pulses of 60 ns duration contain 20 succesive electron bunches which will be extracted at 2.5 MeV from a photoinjector then accelerated through the next structure to the final energy of 51 MeV. Bunches carrying 100 nC are required for this purpose. As a first demonstrating step, 50 nC electron bunches have been produced and accelerated to 2.5 MeV with the 144 MHz ELSA photoinjector at Bruyères le Chatel. For this experiment, we compare the results and the numerical simulations made with PARMELA, MAGIC and MAFIA codes.

  12. Diagnostic value of combined determination of serum CEA, CA72-4 and TSGF levels in patients with gastric cancer

    International Nuclear Information System (INIS)

    Wang Yuyi; Gu Yan

    2007-01-01

    Objective: To explore the diagnostic value of combined determination of serum CEA, CA72-4 and TSGF levels for gastric cancer. Methods: Serum CEA, CA72-4(with RIA) and TSGF (with biochemistry)levels were measured in 31 patients with gastric cancer and 35 controls. Results: As a single tumor marker for diagnosis, the sensitivity of CEA, CA72-4 and TSGF was 23. 0%, 38.0%, 48.0% respectively and the specificity was 23.0%, 38.0%, 48.0% respectively with combined detection of the three markers and assuming two or more markers positive as diagnostic, the sensitivity would be 67.0% and specificity would be 88.0%. Conclusion: Combined determination of serum CEA, CA72-4 and TSGF levels could promote the clinical usefulness for diagnosis of gastric cancer. (authors)

  13. frequency of increase in serum tumor marker carcinoembryonic antigen (cea) levels in primary breast cancer (pbc) patients at the time of diagnosis

    International Nuclear Information System (INIS)

    Riaz, O.; Mahmood, A.; Alvi, Z.A.; Rasul, S.; Haider, N

    2017-01-01

    To determine the frequency of increase in serum tumor marker CEA levels in PBC patients at the time of diagnosis. Study Design: Cross sectional study. Place and Duration of Study: Oncology Department of Combined Military Hospital (CMH) Rawalpindi, from January 2014 to November 2014. Material and Methods: Sixty three female patients with histopathologically confirmed carcinoma of breast and age range from 20 to 70 years from Oncology outpatient department (OPD)/indoor patient department at CMH Rawalpindi, were selected. All patients were staged by clinical and radiological work-up that included physical examination, all base line investigations, serum biomarkers, chest radiograph, ultrasound abdomen and pelvis, bone scan, computed tomography (CT) scan/magnetic resonance imaging (MRI) of the chest (optional). Patients serum carcino-embryonic antigen (CEA) levels were carried out only by blood sampling using chemiluminescent immunoassay with immulite 2000 CEA. Data analysis were done with the help of the Statistical Package for the Social Sciences (SPSS) version 19 software. Cut-off values of serum CEA levels >2.5 ng/ml were taken as elevated. Results: Sixty three female breast cancer patients with histopathologically confirmed carcinoma of breast revealed elevated serum CEA levels in three stages of the disease. The median age was 47 years (range, 20-70 years). Fifteen (23.8%) patients had family history of the breast cancer. Invasive ductal carcinoma (IDCA) was the commonest histology with 60 (95.23%) patients. Most of the patients had advanced stage of the disease. Node positive cases were 53 (84.1%). The frequency of abnormal CEA levels were varying from stage II to stage IV. Elevated serum CEA levels were noted in 4 (28.6%) of stage II, 19 (76%) of stage III and 17 (77.3%) patients of stage IV, respectively. Overall percentage increase in levels of serum CEA from stage I through IV were 0%, 6.34%, 30.2%, 26% respectively. The sensitivity of serum CEA in our

  14. Diagnosis of colorectal carcinomas and recurrence with 99m Tc labeled monoclonal anti-CEA-antibody (BW 431/26)

    International Nuclear Information System (INIS)

    Lind, P.; Langsteger, W.; Koeltringer, P.; Eber, O.; Beham, A.

    1989-01-01

    With the introduction of 99m Tc labeled monoclonal antibodies against CEA, a clinically relevant extension can be expected in the diagnosis of colorectal tumors by immunoscintigraphy (IS). This study comprises a total of 31 patients (primary tumors, occult neoplasms with elevated CEA serum level, suspicious recurrences). In primary tumors (n = 14), all coloscopically diagnosed carcinomas were confirmed and correctly localised by IS (n = 8). In 4 cases IS was true negative, in one case false positive; in one patient a stomach adenocarcinoma could be demonstrated. In the diagnosis of recurrences (n = 17) IS revealed an uptake in TCT (transmission computed tomography) and coloscopically suspicious areas in 10 cases. In 6 cases IS was negative (5 true negative findings in scar or granulation tissue, 1 false negative finding in paraaortal lymphnodes). In one patient the raised CEA level was due to multiple liver metastases, a local recurrence could not be detected. Elevated serum CEA-levels were found only in 10 of 19 patients with true positive IS. In postoperative cancer care IS with 99m Tc-labeled anti-CEA antibody (MAK BW 431/26) plays a preeminent role in the exclusion or diagnosis of kolorectal recurrences in case of ambiguous TCT or endoscopic findings. (Author)

  15. Foreword and introductory comments to CEA annual report 1989

    International Nuclear Information System (INIS)

    1990-01-01

    This article is a foreword to the annual report of the Commisariat a l'Energie Atomique (CEA) and summarises the main achievements of the research teams such as the commissioning of the electron-positron collision ring (LEP), the fuel reprocessing plant at The Hague, the PROTEINE 2000 programme, the laser enrichment programme and advances in microelectronics. (author)

  16. Phase I Escalating-Dose Trial of CAR-T Therapy Targeting CEA+ Metastatic Colorectal Cancers.

    Science.gov (United States)

    Zhang, Chengcheng; Wang, Zhe; Yang, Zhi; Wang, Meiling; Li, Shiqi; Li, Yunyan; Zhang, Rui; Xiong, Zhouxing; Wei, Zhihao; Shen, Junjie; Luo, Yongli; Zhang, Qianzhen; Liu, Limei; Qin, Hong; Liu, Wei; Wu, Feng; Chen, Wei; Pan, Feng; Zhang, Xianquan; Bie, Ping; Liang, Houjie; Pecher, Gabriele; Qian, Cheng

    2017-05-03

    Chimeric antigen receptor T (CAR-T) cells have shown promising efficacy in treatment of hematological malignancies, but its applications in solid tumors need further exploration. In this study, we investigated CAR-T therapy targeting carcino-embryonic antigen (CEA)-positive colorectal cancer (CRC) patients with metastases to evaluate its safety and efficacy. Five escalating dose levels (DLs) (1 × 10 5 to 1 × 10 8 /CAR + /kg cells) of CAR-T were applied in 10 CRC patients. Our data showed that severe adverse events related to CAR-T therapy were not observed. Of the 10 patients, 7 patients who experienced progressive disease (PD) in previous treatments had stable disease after CAR-T therapy. Two patients remained with stable disease for more than 30 weeks, and two patients showed tumor shrinkage by positron emission tomography (PET)/computed tomography (CT) and MRI analysis, respectively. Decline of serum CEA level was apparent in most patients even in long-term observation. Furthermore, we observed persistence of CAR-T cells in peripheral blood of patients receiving high doses of CAR-T therapy. Importantly, we observed CAR-T cell proliferation especially in patients after a second CAR-T therapy. Taken together, we demonstrated that CEA CAR-T cell therapy was well tolerated in CEA + CRC patients even in high doses, and some efficacy was observed in most of the treated patients. Copyright © 2017 The American Society of Gene and Cell Therapy. Published by Elsevier Inc. All rights reserved.

  17. Aeroacoustics research in Europe : the CEAS-ASC report on 2007 highlights

    NARCIS (Netherlands)

    Brouwer, H.H.; Rienstra, S.W.

    2008-01-01

    The Council of European Aerospace Societies (CEAS) Aeroacoustics Specialists Committee (ASC) supports and promotes the interests of the scientific and industrial aeroacoustics community on a European scale and European aeronautics activities internationally. In this context, "aeroacoustics"

  18. An Information Building on Radioactivity and Nuclear Energy for the French CEA Cadarache Research Center - 13492

    Energy Technology Data Exchange (ETDEWEB)

    Brunel, Guy; Denis, Dominique; Boulet, Alain [Commissariat a l' energie Atomique et aux Energies Alternatives - CEA-Cadarache, DEN/CEACAD/UCAP, 13108 Saint Paul lez Durance Cedex (France)

    2013-07-01

    The CEA Cadarache research center is one of the 10 research centers of the French Alternative Energies and Atomic Energy Commission (CEA). Distributed throughout various research platforms, it focuses on nuclear fission, nuclear fusion, new energy technologies (hydrogen, solar, biomass) and fundamental research in the field of vegetal biology. It is the most important technological research and development centers for energy in Europe. Considering the sensitive nature of nuclear activities, the questions surrounding the issue of radioactive waste, the nuclear energy and the social, economic and environmental concerns for present and future generations, the French Government asked nuclear actors to open communication and to give all the information asked by the Local Information Commission (CLI) and the public [1]. In this context, the CEA Cadarache has decided to better show and explain its expertise and experience in the area of nuclear energy and nuclear power plant design, and to make it available to stakeholders and to the public. CEA Cadarache receives each year more than 9000 visitors. To complete technical visits of the research facilities and laboratories, a scientific cultural center has been built in 2011 to inform the public on CEA Cadarache research activities and to facilitate the acceptance of nuclear energy in a way suited to the level of knowledge of the visitors. A modern interactive exhibition of 150 m{sup 2} allows visitors to find out more about energy, CEA Cadarache research programs, radioactive waste management and radiological impact on the research center activities. It also offers an auditorium for group discussions and for school groups to discover science through enjoyment. This communication center has received several thousand visitors since its opening on October 2011; the initial results of this experience are now available. It's possible to explain the design of this exhibition, to give some statistics on the number of the

  19. The evaluation of diagnostic value of the tumor markers: CCSA-2 and CEA in colorectal cancer.

    Science.gov (United States)

    Knychalski, Bartłomiej; Lukieńczuk, Tadeusz

    2012-02-01

    Finding the biomarker or biomarkers with high sensitivity and specificity in colorectal cancer, and thus a high diagnostic value will determine their clinical usefulness in clinical practice. An effective noninvasive blood test would be an ideal method to detect colorectal cancer. Discovered in 2007 a novel tumor marker CCSA-2 showes a promising results in patients with colorectal cancer. THE AIM OF THE STUDY was the evaluation of diagnostic and clinical value of a novel marker - colon cancer specific antigen-2 (CCSA-2) in colorectal adenocarcinoma in comparison to carcinoembryonic antigen (CEA) in patients operated during the years 2008 to 2010 at Wrocław Medical University 1st Department and Clinic of General, Gastroenterological and Endocrinologic Surgery. The study was performed on 40 patients with colorectal cancer and 40 patients in control group consisted of healthy subjects who had colonoscopy examinations with negative results (no pathology in the colon was found). The obtained results were statistically analyzed using nonparametric tests - Mann Whitney U and Kruskal-Wallis and Spearman's rank correlation coefficients. To determine the clinical value of CCSA-2 and CEA in those groups, their sensitivity and specifity was evaluated using ROC analysis. This analysis determines the accuracy and diagnostic value of both tests. There was a positive correlation between markers in patients with colorectal cancer and a statistically significant relationship according to which respondents with higher concentrations of CCSA-2 also have higher concentrations of CEA (R=0.754, ptumor markers increase and correlate with the clinical progression of the disease. Accuracy of CCSA-2 test using ROC analysis showed a slightly lower measurement of antigen CCSA-2 as diagnostic value in colorectal cancer in comparison to measurement of antigen CEA (accuracy of tests: CCSA-2 - 52%, CEA - 60%). CCSA-2 as a single tumor marker has a low diagnostic value in colorectal cancer because

  20. An Information Building on Radioactivity and Nuclear Energy for the French CEA Cadarache Research Center - 13492

    International Nuclear Information System (INIS)

    Brunel, Guy; Denis, Dominique; Boulet, Alain

    2013-01-01

    The CEA Cadarache research center is one of the 10 research centers of the French Alternative Energies and Atomic Energy Commission (CEA). Distributed throughout various research platforms, it focuses on nuclear fission, nuclear fusion, new energy technologies (hydrogen, solar, biomass) and fundamental research in the field of vegetal biology. It is the most important technological research and development centers for energy in Europe. Considering the sensitive nature of nuclear activities, the questions surrounding the issue of radioactive waste, the nuclear energy and the social, economic and environmental concerns for present and future generations, the French Government asked nuclear actors to open communication and to give all the information asked by the Local Information Commission (CLI) and the public [1]. In this context, the CEA Cadarache has decided to better show and explain its expertise and experience in the area of nuclear energy and nuclear power plant design, and to make it available to stakeholders and to the public. CEA Cadarache receives each year more than 9000 visitors. To complete technical visits of the research facilities and laboratories, a scientific cultural center has been built in 2011 to inform the public on CEA Cadarache research activities and to facilitate the acceptance of nuclear energy in a way suited to the level of knowledge of the visitors. A modern interactive exhibition of 150 m 2 allows visitors to find out more about energy, CEA Cadarache research programs, radioactive waste management and radiological impact on the research center activities. It also offers an auditorium for group discussions and for school groups to discover science through enjoyment. This communication center has received several thousand visitors since its opening on October 2011; the initial results of this experience are now available. It's possible to explain the design of this exhibition, to give some statistics on the number of the visitors

  1. Clinical value of combined determination of serum and hydrothorax fluid levels of CEA, CA125, NSE in the diagnosis of lung cancer

    International Nuclear Information System (INIS)

    Su Wentang; Shu Lingling; Yang Huaxi

    2007-01-01

    Objective: To study the clinical value of combined determination of CEA, CA125, NSE levels both in serum and hydrothorax fluid in the diagnosis of lung cancer. Methods: Serum and hydrothorax fluid levels of CEA, CA125, NSE were determined with RIA in 88 patients with lung cancers, 100 patients with inflammatory hydrothorax, and 50 controls. Results: The levels of serum and hydrothorax fluid CEA, CA125, NSE in lung cancer patients were significantly higher than those in patients with inflammatory hydrothorax and controls (P <0.05). In lung cancer group, the positive rate of combined detection of serum CEA, CA125, NSE was 70.5%, the positive rate of combined detection of hydrothorax fluid CEA, CA125, NSE was 79.5% and the positive rate of combined detection of serum and hydrothorax fluid three kinds of tumor markers was 87. 5%. Conclusion: Combined detection of serum and hydrothuax fluid levels of CEA, CA125, NSE is to be advocated because of higher sensitivity for diagnosis of lung cancer. (authors)

  2. 3rd CEAS Specialist Conference on Guidance, Navigation and Control

    CERN Document Server

    Drouin, Antoine; Roos, Clément

    2015-01-01

    The two first CEAS (Council of European Aerospace Societies) Specialist Conferences on Guidance, Navigation and Control (CEAS EuroGNC) were held in Munich, Germany in 2011 and in Delft, The Netherlands in 2013. ONERA The French Aerospace Lab, ISAE (Institut Supérieur de l’Aéronautique et de l’Espace) and ENAC (Ecole Nationale de l’Aviation Civile) accepted the challenge of jointly organizing the 3rd edition. The conference aims at promoting new advances in aerospace GNC theory and technologies for enhancing safety, survivability, efficiency, performance, autonomy and intelligence of aerospace systems. It represents a unique forum for communication and information exchange between specialists in the fields of GNC systems design and operation, including air traffic management. This book contains the forty best papers and gives an interesting snapshot of the latest advances over the following topics: l  Control theory, analysis, and design l  Novel navigation, estimation, and tracking methods l  Aircr...

  3. Protocolo de actuación ante la rosácea en la farmacia comunitaria

    Directory of Open Access Journals (Sweden)

    Espinosa Suances A

    2016-06-01

    Full Text Available La rosácea es una dermatosis facial inflamatoria, recidivante y crónica, que con frecuencia demanda consulta en la farmacia comunitaria. Orientado hacia la práctica clínica del farmacéutico comunitario, este artículo revisa y sintetiza los conceptos clásicos y los avances más recientes en la comprensión y el tratamiento de esta enfermedad cutánea. Finalmente, propone un protocolo para la asistencia de pacientes con rosácea en la farmacia comunitaria.

  4. Clinical significance of changes of serum levels of SIL-2R and CEA in patients with lung cancer after chemotherapy

    International Nuclear Information System (INIS)

    Rui Zhilian

    2004-01-01

    Objective: To investigate the changes of serum levels of SIL-2R and CEA after chemotherapy in patients with lung cancer. Methods: Serum levels of SIL-2R (with ELISA) and CEA (with RIA) were measured in 31 patients with lung cancer both before and after chemotherapy as well as in 35 cantrols. Results: Before chemotherapy, both serum SIL-2R and CEA levels in the patients were significantly higher than those in the controls (P 0.05), but the serum SIL-2R levels in the patients remained significantly higher than those in the controls (P<0.05). Conclusion: Determination of changes of serum SIL-2R and CEA levels after chemotherapy might be helpful for predicting the treatment outcomes in patients with lung cancer. (author)

  5. French achievements in the field of nuclear electronics; Realisations francaises dans le domaine de l'electronique nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    Doireau, M; Fabre, R; Guillon, H; Guyot, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Nuclear electronic equipment used by the french Atomic Energy Commission has been developed, with an increasing participation of the radioelectric industry (manufacture under AEC license, contracts for prototypes). The equipment for general use has been standardized and satis the technical specification sheets in which are specified more particularly, the conditions for construction, the choice of the spare parts and the conditions for acceptance by the french AEC at factory. The electronic equipment is classified in nine classes, and a brief description of the principal instruments is given in each class. The reliability of the equipment in use is satisfactory, as it is shown by the mean frequency of faults per 1000 hours operation. (author)Fren. [French] L'appareillage d'electronique nucleaire utilise au Commissariat a l'Energie atomique fran is a ete developpe en demandant un concours de plus en plus important a l'industrie radioelectrique (fabrications sous licence CEA, marches de prototypes, etc...). Le materiel d'emploi courant a ete standardise et repond aux specifications de cahiers des charges ou sont precises en particulier les conditions de realisation du materiel, le choix des pieces detachees et les conditions de recette en usine. L'appareillage electronique est classe en neuf rubriques et une description sommaire des principaux appareils est donnee dans chacune des rubriques. La tenue en service du materiel est satisfaisante, ainsi que le montre la frequence moyenne des pannes observees par 1000 heures de fonctionnement. (auteur)

  6. Le contrôle de gestion environnementale d'une entreprise

    OpenAIRE

    Marquet-Pondeville, Sophie

    2001-01-01

    Dans cette recherche, nous étudions comment s’opère le contrôle de gestion environnementale. Cette problématique est abordée dans une perspective contingente et nous proposons un modèle théorique qui met en évidence l’impact de certaines variables sur les systèmes de contrôle de la gestion environnementale. Certains liens présents dans ce modèle sont discutés à travers une étude de cas.

  7. Deterministic Role of CEA and MSI Status in Predicting Outcome of CRC Patients: a Perspective Study Amongst Hospital Attending Eastern Indian Populations.

    Science.gov (United States)

    Koyel, Banerjee; Priyabrata, Das; Rittwika, Bhattacharya; Swati, Dasgupta; Soma, Mukhopadhyay; Jayasri, Basak; Ashis, Mukhopadhyay

    2017-12-01

    Carcinoembryonic antigen (CEA) is an important deterministic factor in predicting colorectal carcinoma (CRC) progression. It is also evident that microsatellite instability (MSI) which results in a hypermutable phenotype of genomic DNA is common in CRC. Owing to the scarcity of reports from India, our aim of this study was to understand the clinicopathological correlations of CEA status with surgery and chemotherapy, correlate the same with socio-demographic status of the patients, determine the MSI status amongst them and understand the prognostic implications of CEA and MSI as CRC progression marker amongst patients. The serum CEA level was estimated by chemiluminescence assay (CLIA). Serum liver enzyme assay was carried out following the manufacturer's instructions using auto-analysers (E. Merck and Sera mol. Health Care, India). MSI analysis was carried out by PCR-SSCP. From our study, most frequently detected colorectal cancer was in 40-49 years age group (25.26%) with 61.05% male and 38.95% females. CEA showed a significant association with higher TNM staging, tumour size, smoking habit and MSI status ( p   0.05). After surgery and chemotherapy, CEA and WBCs were decreased significantly ( p   0.05). Overall, microsatellite instability was observed in approximately 40% of the populations. From our study, it was also evident that for both, MSI and abnormal CEA level predicted poor prognosis for the patient (by using Kaplan-Meier survival analysis; p  = 0.04). Thus, CEA and initial MSI status can be used as prognostic markers of CRC.

  8. Anti-CEA monoclonal antibody in the diagnosis of colorectal, lung and ovarian carcinoma

    International Nuclear Information System (INIS)

    Jiang, N.; Lu, B.; Lu, X.; Sha, X.; Yue, D.

    2000-01-01

    This study evaluated the diagnostic value of radioimmnoimaging (RII) with 99 Tc labeled monoclonal antibody C50, raised originally against carcinoembryonic antigen (anti-CEA) in various tumors. 152 pathologically confirmed patients with a tumor were imaged prior to surgery with an anti-CEA monoclonal antibody labeled with 99 Tc. There were 115 patients with ovarian carcinoma, 26 patients with colorectal carcinoma and 11 patients with lung carcinoma. Images were acquired at 3-6 h post injection and were analyzed by the double blind method. Images of patients with ovarian cancer were compared with B-ultrasound images. Immunohistochemical staining was performed on all cases of colorectal cancer. All RII images demonstrated excellent contrast, clear lesions, and no serious toxic or other side reactions occurred. Transient chills and fever were observed in 3 cases. This study showed a sensitivity=88.2%, specificity=83.2%, and an accuracy=4.0%. The smallest lesion size detected was 2 x 2 cm. The total combined lesion detection rate for primary, metastatic, and recurrence lesions was 84.4%. We conclude that 99 Tc labeled anti-CEA MoAb C50 can be used in the diagnosis of colorectal carcinoma, ovarian carcinoma, and lung carcinoma

  9. Serum tumor marker CYFRA 21-1 in the diagnostics of squamous cell lung cancer - comparison with CEA

    International Nuclear Information System (INIS)

    Berzinec, P.; Letkovicova, M.; Arpasova, M.; Zuffova, H.

    1996-01-01

    The aim of the study was to test the diagnostic value tumor marker CYFRA 21-1 for squamous cell lung cancer (SQCLC) in comparison with carcinoembryonic antigen (CEA). Ninety-one patients were induced in this study: 56 with SQCLC - Group I, 25 with other types of lung cancer - Group II, 10 with benign respiratory tract diseases - Group III. Median CYFRA 21-1 serum concentration (ng/ml) was: in Group I: 4.52 (0.94 - >16), in Group II: 3.58 (1.72 - >16), in Group III: 2.05 (0.99 - 3.41). Median CEA serum concentration (ng/ml) was: in Group I: 4.49 (076- >20), in Group II: 3.32 (1.17 - >20), in Group III: 3.09 (1.84 - 6.37). There was a highly significant difference between the levels of CYFRA 21-1 in group I and Group III (p < 0.001), but there was no statistically significant difference between the levels of CEA in Group I and III. Sensitivity of CYFRA 21-1 by the cut-off 3.33 ng/ml in the diagnostics of SQCLC was 0.68, specificity 0.090, positive predictive value 0.91, negative predictive value 0.65. Sensitivity of CEA by cut-off 4.61 ng/ml was 0.5 by the same specificity 0.90. CYFRA 21-1 has high sensitivity, specificity and positive predictive value in the diagnostics of SQCLC. Sensitivity of CYFRA 21-1 is significantly higher than sensitivity of CEA in this settings. (author)

  10. Lele des intervenants non gouvernementaux dans le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Ce projet servira à déterminer les facteurs stratégiques et réglementaires qui ont contribué ou nui aux efforts visant à permettre aux fournisseurs non gouvernementaux de participer au renforcement des systèmes de santé. Lele des fournisseurs de ... Climate Change and Water Adaptation Options. The impacts of climate ...

  11. Report transparency and nuclear safety 2007 CEA Saclay

    International Nuclear Information System (INIS)

    2007-01-01

    This report presents the activities of the CEA Center of Saclay for the year 2007. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially two public consultation on release authorizations and the Neurospin installations, the dismantling of the 49 nuclear installation, the shutdown of the learning reactor ULYSSE are detailed. (A.L.B.)

  12. Annual report of the Association EURATOM-Cea 2004 (full report)

    International Nuclear Information System (INIS)

    Magaud, Ph.; Le Vagueres, F.

    2004-01-01

    This annual report summarizes activities performed by the EURATOM-Cea association in 2004. The activities carried out in the field 'physics integration' are mainly linked to neutral beam developments and to the development of diagnostic components. In particular, in-situ diagnostics of the plasma facing surface have been studied. Concerning 'vessel activities', the manufacturing of the ITER primary first wall panel by HIP forming has been investigated. A dummy mock-up was produced to validate the manufacturing feasibility. A new welding process able to improve welding productivity has been investigated, it is based on a hybrid laser/TIG process called Hybrid Laser Conduction Welding. A ITER first wall mock-up has been successfully manufactured using induction brazing. In the field 'magnets', EURATOM-Cea association was involved to provide input information for establishing the final dimension details of the ITER cryo-plant. EURATOM-Cea is also involved with the design of different parts of the ITER magnet system and the fabrication of mock-ups for some critical parts of the coils. In the field 'tritium breeding and materials', activities have mainly concerned the improvement and completion of the TBM (tritium breeding module) engineering design. A new batch of 1 kilogram of Li 2 TiO 3 pebbles with a size distribution in the range 0.6 to 0.8 mm was produced in 2004. Concerning materials, activities were focused on the EUROFER, a reduced activation martensitic steel. Activities performed in the field 'system studies' are dedicated to the power plant conceptual studies. In 2004, activities were focused on the reactor model AB, based on a helium-cooled lithium-lead blanket. (A.C.)

  13. Radioimmunoscintigraphy with 99mTc-labelled anti-CEA monoclonal antibodies in colorectal carcinoma patients

    International Nuclear Information System (INIS)

    Sergieva, S.; Baychev, G.; Tzingilev, D.; Delijski, T.; Kirova, G.; Kirilova, B.; Nenovska, M.

    1998-01-01

    Sixteen patients (2 female and 14 male, aged 42-75) were given intravenous injections with 99m Tc (555-740 MBq)-labelled anti-CEA MAb (CEA-Scan, Mallinckrodt Medical and M-CEATEC, Sorin Biomedica). Five of them were with duly established or established or suspected primary colorectal carcinoma, and eleven were studied postoperatively after recording an increase CEA levels in serum. The patients were scanned within 4-24 h of infusion using planar and tomographic imaging in rotation gamma-camera DIACAM (Siemens). At all 16 patients 27 true positive results were obtained: in 7 primary colorectal carcinomas, 5 locally recurrent tumors, 7 liver metastases, 6 lymphogeneous lesions and two - in the ureteral region. True negative results were established at three patients, false positive - in one patient with chronic inflammation, and false negative results - in 3 cases with liver metastases foci < 8 mm. Having 90 % sensitivity, 75 % specificity and 82.3 % accuracy, radioimmunoscintigraphy is a highly informative and sensitive imaging method for diagnosing and following up of primary, recurrent and metastatic foci in colorectal carcinoma patients. (author)

  14. Actinides exposure: review of Ca-DTPA injections inside Cea-Cogema plants; Exposition aux actinides: bilan des injections de Ca-DTPA dans les centres CEA-Cogema

    Energy Technology Data Exchange (ETDEWEB)

    Grappin, L.; Berard, P.; Beau, P.; Carbone, L.; Castagnet, X.; Courtay, C.; Le Goff, J.P.; Menetrier, F.; Neron, M.; Piechowski, J. [CEA Cadarache, Dir. de l' Energie Nucleaire, Dept. de Soutien en surete et securite, Sev. de Sante au Travail, 13 - Saint-Paul-lez-Durance (France)

    2006-07-01

    Ca-DTPA has been used for medical treatment of plutonium and americium contaminations in the CEA and COGEMA plants from 1970 to 2003. This report is a survey of the injections administered of Ca-DTPA as a chelating molecule. This report will be a part of the AMM process for Ca-DTPA by intravenous administration submitted by the Central Pharmacy of the french Army. Out of 1158 injections administered to 469 persons, 548 events of possible or confirmed contaminations were reported. These employees were followed by occupational physicians according to the current regulations. The first part of the report is a synthesis of the most recent findings. Due to its short biological period and its limited action in the blood, Ca-DTPA does not chelate with plutonium and americium as soon as these elements are deposited in the target organs. It justifies an early treatment, even in cases of suspected contamination followed by additional injections if necessary. The second part presents data concerning these 1158 injections (way of contamination, posology, adverse effects...). These incidents took place at work, were most often minor, not requiring follow-up treatment. A study concerning the effectiveness of the product was done on a group of people having received 5 or more injections. These results were compared with effectiveness estimated from theoretical basis. Posologies and therapeutic schemes were proposed based on these observations. Additional studies are needed to confirm these findings. This document is the first synthesis in this field. It is the result of a collective work having mobilized the occupational medicine departments, the laboratories of CEA and COGEMA and a working group CEA-COGEMA-SPRA. (authors)

  15. Report of transparency and nuclear safety 2007 CEA Fontenay aux Roses; Rapport transparence et securite nucleaire 2007 CEA Fontenay aux Roses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This report presents the activities of the CEA Center of Fontenay aux roses for the year 2007. After many years of decommissioning and dismantling of nuclear installations, the Center is now devoted (since 2005) to the development of research programmes on biology and biomedical technologies. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. (A.L.B.)

  16. Uptake of radiolabeled anti-CEA antibodies in human colorectal primary tumors as a function of tumor mass

    International Nuclear Information System (INIS)

    Williams, L.E.; Bares, R.B.; Buell, U.; Fass, J.; Schumpelick, V.; Hauptmann, S.

    1993-01-01

    An inverse correlation has been demonstrated between tumor uptake (u, in units of % injected dose/kg) of monoclonal antibody (Mab) and tumor mass (m, in units of g) for colorectal carcinoma in a series of 19 consecutive patients. The correlation (ρ=-0.510), developed using surgical samples was of the form u=ab b and was significant at the 2% level of confidence. All tumors were positive for carcinoembryonic antigen (CEA) and the radiopharmaceutical was in iodine-131 labeled anti-CEA Mab. Such correlations have been predicted earlier from murine and rat tumor uptake data. The slope parameter (b) was -0.362, a number consistent with the previous value (-0.382) found in anti-CEA experiments in mice bearing human xenograft LS174T tumors. (orig.)

  17. The role of tumor markers (CEA, TPA, CA 19-9) in colon and rectum carcinomas

    International Nuclear Information System (INIS)

    Cangemi, V.; Volpino, P.; Fiori, E.; Giammarco, A.; Piat, G.

    1987-01-01

    We have evaluated the diagnostic efficacy (sensitivity, specificity, accuracy, predictive malignancy index) of CEA, TPA, CA 19-9 in colon and rectum tumors (56 cases), the difference in behaviour of these markers in relation to the stage and grading of the cancer, their reliability regarding postsurgical relapses and/or metastases. The sensitivity of CEA (>10 ng/ml), TPA (>130 U/L), CA 19-9 (>37 u/ml) for diagnostic purpose was rather limited (28.6% - 30% - 18.5%) with a malignancy prediction value of 100% - 81.8% - 62.5%. With regard to relapses and/or metastases, the diagnostic efficacy of the marker proved to be evident only for CEA, TPA, CA 19-9 value greater than 25 ng/ml, 250 U/L and 100 u/ml. The use of thethree markers together was certainly an advantage both for primitive tumors (sensitivity: 52.8%) and relapses and/or metastases after surgery (sensitivity: 66.7%)

  18. Chemistry of complexing molecules and environment. Report of the working group of the Cea ''mission environment''

    International Nuclear Information System (INIS)

    Petit, J.C.

    1998-01-01

    The Working group 'Chemistry of Complexing Molecules and Environment' of the Mission Environment (AG/ENV) identified themes for an original positioning of CEA on important issues of environmental research if a sufficiently strong demand appears. The research of CEA on the environment should be complementary to actions undertaken by other partners (official institutions, research organizations and industrial firms). The themes suggested are: the synthesis of new chelating molecules and new materials having specific properties, with the support of theoretical chemistry and modeling, analytical physical chemistry and speciation of species in relation to their eco-toxicity and their biogeochemical mobility in the natural environment. These themes, illustrated by examples of actions in progress at CEA or likely to be launched quickly, draw largely from recognized competences of the teams, generally developed for finalized nuclear applications: experimental, theoretical and instrumental competences. (author)

  19. Evaluating the efficacy of tumor markers CA 19-9 and CEA to predict operability and survival in pancreatic malignancies.

    Science.gov (United States)

    Mehta, Jay; Prabhu, Ramkrishna; Eshpuniyani, Priya; Kantharia, Chetan; Supe, Avinash

    2010-01-01

    Using CA 19-9 and CEA (elevated > 2 times of normal) as predictors in determining operability and survival in pancreatic tumors. Levels of CA 19-9 and CEA were measured (pre and post operatively) in 49 patients of pancreatic malignancy. CECT was performed for diagnosis and staging. An experienced surgeon determined the operability. The levels of tumor markers were correlated with the operability and the survival based on CECT and intra-operative findings. 16/24 (67%) patients with CA 19-9 levels (CEA levels (CEA levels (p = 0.003) were found to be non-resectable. Of the 27 patients, found resectable on CECT, 5 were non-resectable intra-operatively. All of these had elevated levels of CA 19-9 and 4/5 (80%) had elevated levels of CEA. Only 5/21 (23%) non-resectable patients, with elevated levels of CA 19-9 reported at 1 year follow up. None of the non-resectable patients with CA 19-9 levels > 1000 U/ml reported at 6 month follow-up. None of the resectable patients pre-operatively showed evidence of recurrence. All achieved normal values post surgery. Elevated levels of CA 19-9 and CEA (> 2 times) predict increased chances of inoperability and poor survival in pancreatic tumors. Levels > 3 times had increased risk of inoperability even in patients deemed resectable on CT-Scan. Diagnostic laparoscopy would be beneficial in these patients. Levels of CA 19-9 (> 1000 U/ml) indicate a dismal survival in non-resectable group of patients.

  20. Radioactivity and radioprotection: the every day life in a nuclear installation. Press tour at CEA/GRENOBLE 18 november 1999

    International Nuclear Information System (INIS)

    1999-11-01

    In the framework of the public information, this paper gives a general information on the radioactivity and the radioprotection at the CEA/Cadarache center. A first part is devoted to a presentation of the radioactivity with definitions and radiation effects on the human being and the environment. An other part presents the radioprotection activities and regulations. The last part deals with specific activities of the CEA/Cadarache: the CASCAD installations for spent fuels storage, the LECA Laboratory for the Examination of Active Fuels and a dismantling installation for big irradiated objects. Historical aspects of the CEA/Cadarache are also provided. (A.L.B.)

  1. Report transparency and nuclear safety 2007 CEA Marcoule

    International Nuclear Information System (INIS)

    2007-01-01

    This report presents the activities of the CEA Center of Marcoule for the year 2007. Since its creation in 1955 the center realizes industrial and scientific activities relative to the civil and military applications of the radioactivity. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially the following two base activities are detailed: Atalante and Phenix. (A.L.B.)

  2. Historical review of CEA researches on uranium enrichment

    International Nuclear Information System (INIS)

    Camarcat, N.

    1997-01-01

    The various uranium enrichment processes that have been studied at the CEA since 1953 are briefly reviewed: gaseous diffusion (which led to the construction of EURODIF plant), chemical treatments (which were abandoned in 1988 for cost reasons), gaseous ultracentrifugation, electromagnetic processes, laser techniques (since 1980) and especially the SILVA technique (atomic vapour laser isotopic separation) which could take the place of the gaseous diffusion technique when the EURODIF plant will need to be renewed before 2010

  3. Report transparency and nuclear safety 2007 CEA Cadarache

    International Nuclear Information System (INIS)

    2007-01-01

    This report presents the activities of the CEA Center of Cadarache for the year 2007. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. More especially the report discusses the beginning of the RJH reactor construction, the fourth generation reactors research programs, the implementing of la Rotonde the new radioactive wastes management installation, the renovation of the LECA. (A.L.B.)

  4. Le stéréotype dans le roman policier

    Directory of Open Access Journals (Sweden)

    Marion François

    2009-12-01

    Full Text Available Le roman policier offre à l’étude du stéréotype une grande variété de redondances, lexicales et structurelles, qui permettent d’éclairer le concept même de genre, en fait issu du constat de stéréotypie. Il est également manifeste que contrairement aux idées reçues, les clichés font du texte policier un texte littéraire, parce qu’ils naissent d’images associées, distinctes de la réalité, qui révèlent d’ailleurs le cheminement même de l’écriture. Par ailleurs ces images jouent un rôle fondamental dans le plaisir du lecteur, comme dans les contes de fées de notre enfance. Les clichés ouvrent la porte des fantasmes : le stéréotype rejoignant l’archétype, les clichés policiers réactivent de nombreux mythes, le texte évoquant l’Autre Scène. Le constat de stéréotypie provoque l’écriture, en particulier parodique, et stimule le renouvellement et l’essaimage des clichés dans toutes sortes de textes, qui bénéficieront de la présence du déjà-lu, laquelle donne au lecteur une assise pour affronter l’inconnu et une expérience pour apprécier la nouveauté.

  5. Criticality accident studies and methodology implemented at the CEA

    International Nuclear Information System (INIS)

    Barbry, Francis; Fouillaud, Patrick; Reverdy, Ludovic; Mijuin, Dominique

    2003-01-01

    Based on the studies and results of experimental programs performed since 1967 in the CRAC, then SILENE facilities, the CEA has devised a methodology for criticality accident studies. This methodology integrates all the main focuses of its approach, from criticality accident phenomenology to emergency planning and response, and thus includes aspects such as criticality alarm detector triggering, airborne releases, and irradiation risk assessment. (author)

  6. RELAP4/MOD-5-CEA pump coastdown experiment simulation

    International Nuclear Information System (INIS)

    Borges, R.C.; Freitas, R.L.

    1988-07-01

    Since is important the theoretical-experimental comparison to evaluate the computer codes, these paper presents the simulation with RELAP4/MOD5 Code of a loss of power energy in the pump of the ''Circuito Experimental de Agua-CEA''. From the results attained, the existing models in the Code showed to be very satisfatory quantitative and qualitative behavior of the attained experimental results. (author) [pt

  7. Reemplazo de áreas arboladas por chaparrales y comunidades herbáceas en el período 1970-2000 en una microcuenca de Durango, México

    Directory of Open Access Journals (Sweden)

    Marco Antonio Márquez Linares

    2012-02-01

    Full Text Available Se realizó una comparación entre la cobertura de la vegetación existente en la microcuenca del arroyo “El Carpintero” cercana a la ciudad de Durango, México, en 1970 y 2000. Las áreas dominadas por chaparrales y por especies herbáceas aumentaron su extensión de 9 571 a 11 754 ha y de 2 188 a 6 774 ha, respectivamente, a costa de la superficie dominada por arbóreas que disminuyó de 12 952 a 6 193 ha. La tasa de deforestación anual fue de -2.43%. Las principales fuerzas que provocaron este cambio fueron: el manejo de recursos basado en la ganadería extensiva, la agricultura de temporal, la extracción de leña como principal fuente de energía y los incendios forestales.

  8. Elevated Levels of Serum Tumor Markers CEA and CA15-3 Are Prognostic Parameters for Different Molecular Subtypes of Breast Cancer

    OpenAIRE

    Shao, Yingbo; Sun, Xianfu; He, Yaning; Liu, Chaojun; Liu, Hui

    2015-01-01

    Background & Aims The utility of measuring carcinoembryonic antigen(CEA) and cancer antigen 15-3 (CA15-3) levels in patients with breast cancer remains controversial. The present study aims to investigate the prognostic value of preoperative serum CEA and CA15-3 levels in breast cancer patients. Methods Serum preoperative CEA and CA 15-3 concentration levels were measured in a total of 432 breast cancer patients. The association of tumor markers levels with clinicopathological parameters and ...

  9. The plan contract between CEA and the French state for 2001-2004

    International Nuclear Information System (INIS)

    Pijaudier-Cabot, F.

    2001-01-01

    The French energy commission (CEA) has defined 3 axis of development in the framework of a 4 year contract with the government. The first axis is to propose technological solutions for improving competitiveness of nuclear energy, for managing nuclear wastes and for assuring safety at any step of the nuclear industry. The second axis concerns promoting new technologies in the fields of energy, of information and of bio-engineering. CEA will develop studies about the use of hydrogen as an alternative energy for transport. The third axis deals more particularly with fundamental research in the fields of energy, of environment, of bio-technologies and of health (research about the prion for instance). The subsidy given by the state has been increased by 3.4% for 2001. (A.C.)

  10. Diagnostic significance of tumor markers CEA, CA50 and CA19-9 for colorectal cancer

    International Nuclear Information System (INIS)

    Chen Yumei; Huang Gang

    2005-01-01

    Objective: To investigate the expression and diagnostic significance of three serum tumor markers (CEA, CA50, CA19-9) in patients with colorectal cancer, with special emphasis on their combined assay. Methods: Serum CEA, CA19-9 levels (with chemiluminescence immunoassay) and CA50 levels (with immunoradiometric assay) were determined in 94 patients with colorectal cancer, 20 patients with benign colorectal disorders and 37 controls. Results: The expressions of the serum tumor markers were significantly higher in patients with colorectal cancer than those in patients with benign colorectal disorders and controls (P<0.05). There was no significant difference between the levels in the latter two groups. CEA assay had the highest sensitivity (57.4%) and specificity (85.9%). Combined assay of the three could enhance both the sensitivity (62.7%) and specificity (96.5%). The serum levels of the markers were significantly higher in patients with colonic cancer than those in patients with rectal cancer (P<0.05). The levels were positively correlated with the size of the growth and stage of the disease. Serum tumor marker levels were also significantly higher in patients with metastasis (regional/distant) than those in patients without metastasis (P<0.05). Conclusion: Determination of serum CEA, CA50 and CA19-9 levels had definite value for the diagnosis and assessment of the pathology as well as biologic behavior colorectal cancer. Combined assay of the three could enhance the diagnostic sensitivity and specificity. (authors)

  11. Can preoperative CEA and CA19-9 serum concentrations suggest metastatic disease in colorectal cancer patients?

    Science.gov (United States)

    Stojkovic Lalosevic, Milica; Stankovic, Sanja; Stojkovic, Mirjana; Markovic, Velimir; Dimitrijevic, Ivan; Lalosevic, Jovan; Petrovic, Jelena; Brankovic, Marija; Pavlovic Markovic, Aleksandra; Krivokapic, Zoran

    2017-01-01

    This study was designed to investigate the efficiency of preoperative serum carcinoembryonic antigen (CEA) and carbohydrate cancer antigen (CA19-9) levels for diagnosing synchronous liver metastases and lymph node in colorectal carcinoma (CRC) patients. A total of 300 patients with histologically diagnosed CRC were included in this study between May 2014 and March 2015. The data were obtained prospectively from patient's medical records: medical history, demographics, tumor location, differentiation (grade), depth of the tumor (T), lymph node metastases (N), distant metastases (M), lymphatics, venous and perineural invasion, and disease stage. Tumor markers were measured with an electrochemiluminescent assay and the reference value was 5ng/ml for CEA and for Ca19-9, 37u/ml. There was A high statistically significant difference in the levels of serum CEA and CA19-9 between different disease stages of CRC (PCEA (stage I 3.76±8.73; II 5.68±17.27, III 7.56±14.81, and IV 70.90±253.23) and CA 19-9 levels (stage I 9.65±11.03, II 9.83±11.09; III 19.58±36.91, and IV 228.9±985.38, respectively). The mean CEA and CA19-9 serum levels were significantly higher in patients with regional lymph nodes involvement (CEA 37.21±177.85 vs 4.79±9.90, CA19-9 119.51±687.71 VS 12.24±17.69, respectively, PCEA 86.56±277.65 vs. 5.98±12.98, and CA19-9 273.27±1073.46 vs. 4.98±3142, respectively, with PCEA and CA 19-9, 3.5 ng/mL and 7.5 U/mL, respectively. While, a cut-off value for the presence of synchronous liver metastases of these two markers was 3.5ng/mL AND 5.5 U/mL. Our study showed that tumor makers, CEA and CA19-9, can be used as diagnostic factors regarding the severity of CRC specifically to suggest metastatic disease in CRC.

  12. pour le trimestre qui a pris fin le 30 juin 2015

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    30 juin 2015 ... Le CRDI finance des travaux de recherche appliquée ... recherches pour le développement international (le Centre) et de ..... voie de développement et sur la mise en oeuvre des connaissances scientifiques, techniques et autres en .... Les accords expirent à des dates différentes, et le dernier prend fin en.

  13. Le CRDI et la lutte contre le paludisme | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    22 juil. 2011 ... D'autres interventions luttent également contre le paludisme, notamment les moustiquaires imprégnées d'insecticide et les médicaments visant à prévenir le ... Le CRDI appuie le GCRAI depuis les années 1970 et participe avec SIMA au financement de la recherche sur les interactions complexes entre ...

  14. Meeting of Directors and Heads of Department from CEA-Saclay, France

    CERN Multimedia

    Patrice Loïez

    2002-01-01

    Left to right: Ph. Pradelles, M. Jacquemet and T. Taylor in discussion during the December visit of Directors and Heads of Department from the Saclay centre of the French atomic energy commission (CEA) to CERN's LHC magnet test facility. Looking on is Yves Lemoigne.

  15. Combined detection of preoperative serum CEA, CA19-9 and CA242 improve prognostic prediction of surgically treated colorectal cancer patients.

    Science.gov (United States)

    Wang, Jingtao; Wang, Xiao; Yu, Fudong; Chen, Jian; Zhao, Senlin; Zhang, Dongyuan; Yu, Yang; Liu, Xisheng; Tang, Huamei; Peng, Zhihai

    2015-01-01

    We assessed the prognostic significance of preoperative serum carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA19-9) and carbohydrate antigen 242 (CA242) levels in surgically treated colorectal cancer patients. The relationship of preoperative serum CEA, CA19-9 and CA242 levels with disease characteristics was investigated in 310 patients. Correlation between tumor markers was investigated using Pearson correlation test. Univariate and multivariate survival analyses were used to study the relationship between preoperative tumor markers and prognosis [disease free survival (DFS) and overall survival (OS)]. Kaplan-Meier analysis with log rank test was used to assess the impact of tumor marker levels on survival. Positive rate of preoperative serum CEA, CA19-9 and CA242 were 54.84%, 47.42% and 37.10%, respectively. High preoperative CEA level was associated with tumor size (P = 0.038), T stage (P tumor AJCC stage (P = 0.023). Preoperative CA242 positively correlated with CEA (P markers was of independent prognostic value in CRC (HR = 2.532, 95% CI: 1.400-4.579, P = 0.002 for OS; and HR = 2.366, 95% CI: 1.334-4.196, P = 0.003 for DFS). Combined detection of preoperative serum CEA, CA19-9 and CA242 is of independent prognostic value for management of CRC patients treated surgically.

  16. Le livre sur le livre traité de documentation

    CERN Document Server

    Otlet, Paul

    2015-01-01

    Paul Otlet est considéré comme le père des sciences de l'information. Ouvrage fondateur et fondamental, le Traité de documentation. Le livre sur le livre (1934) est l'aboutissement de son travail inlassable pour rassembler, classer et partager les connaissances. Otlet y propose une remarquable synthèse du savoir sur le livre et le document en même temps qu'il anticipe Internet et l'hypertexte. La réédition du Traité de documentation, 70 ans après la disparition de son auteur, coïncide avec la réouverture du Mundaneum à Mons, où le fabuleux héritage documentaire légué par Paul Otlet et Henri La Fontaine est conservé. « Ici, la table de travail n'est plus chargée d'aucun livre. À leur place se dresse un écran et à portée un téléphone. Là-bas, au loin, dans un édifice immense, sont tous les livres et tous les renseignements. De là, on fait apparaître sur l'écran la page à lire pour connaître la réponse aux questions posées par téléphone. » Préfaces de Benoît Peeters (éc...

  17. Values of serum TSGF, CA125 and CEA determination in early diagnosis of ovarian cancer

    International Nuclear Information System (INIS)

    He Jiang; Zhou Yu; Yu Wuzhong; Chou Donghui; Zhou Ying; Zhang Yang; Guo Yong; Wang Yongsheng

    2005-01-01

    To investigate levels of TSGF,CA125 and CEA as a panel for early diagnosis of overian cancer, the levels of three tumor markers(TSGF,CA125 and CEA) in serum were determined in 85 patients with ovarian cancer, 54 patients with benign tumor and 76 healthy control. The results showed that the levels of three tumor markers in ovarian cancer patients were significantly higher than those in benign tumor patients and controls(P<0.05). Combined detection of the three markers may greatly improve the diagnostic accuracy of overian cancer. (authors)

  18. Phase I Hepatic Immunotherapy for Metastases study of intra-arterial chimeric antigen receptor modified T cell therapy for CEA+ liver metastases

    Science.gov (United States)

    Katz, Steven C.; Burga, Rachel A.; McCormack, Elise; Wang, Li Juan; Mooring, Wesley; Point, Gary; Khare, Pranay D.; Thorn, Mitchell; Ma, Qiangzhong; Stainken, Brian F.; Assanah, Earle O.; Davies, Robin; Espat, N. Joseph; Junghans, Richard P.

    2015-01-01

    Purpose Chimeric antigen receptor modified T cells (CAR-T) have demonstrated encouraging results in early-phase clinical trials. Successful adaptation of CAR-T technology for CEA-expressing adenocarcinoma liver metastases (LM), a major cause of death in patients with gastrointestinal cancers, has yet to be achieved. We sought to test intrahepatic delivery of anti-CEA CAR-T through percutaneous hepatic artery infusions (HAI). Experimental Design We conducted a phase I trial to test HAI of CAR-T in patients with CEA+ LM. Six patients completed the protocol, and 3 received anti-CEA CAR-T HAIs alone in dose-escalation fashion (108, 109, and 1010 cells). We treated an additional 3 patients with the maximum planned CAR-T HAI dose (1010 cells X 3) along with systemic IL2 support. Results Four patients had more than 10 LM and patients received a mean of 2.5 lines of conventional systemic therapy prior to enrollment. No patient suffered a grade 3 or 4 adverse event related to the CAR-T HAIs. One patient remains alive with stable disease at 23 months following CAR-T HAI and 5 patients died of progressive disease. Among the patients in the cohort that received systemic IL2 support, CEA levels decreased 37% (range 19–48%) from baseline. Biopsies demonstrated an increase in LM necrosis or fibrosis in 4 of 6 patients. Elevated serum IFNγ levels correlated with IL2 administration and CEA decreases. Conclusions We have demonstrated the safety of anti-CEA CAR-T HAIs with encouraging signals of clinical activity in a heavily pre-treated population with large tumor burdens. Further clinical testing of CAR-T HAIs for LM is warranted. PMID:25850950

  19. A study on the CEA and AFP in Serum of Toombak Users and Smokers in Sudan using Immunoradiometric Assays

    International Nuclear Information System (INIS)

    Abdalla, O.M.; Hassan, A.M.; Shabbo, N.M.; Khalid, M.M.; El-amin, A.M.; Ali, N.I.

    2003-01-01

    Approximately 42% of the sudanese population use toombak as smokers tobacco. Tobacco specific N-nitroso compounds have been detected at high concentration in toombak. This study focused on the possible carcinogenicity of those compounds through the measurement of serum CEA and serum AFP in both tombak users and smokers. 160 subjects were involved with the average age of 32 years ranging from 20 to 60 years. These 160 subjects were categorized into 3 groups (control, smokers, and tombak users). Serum CEA and AFP were measured using an IRMA technique. The mean AFP level in the control, tombak users and smokers groups were 0.94, 1.98 and 2.34 Ku/1 respectively. There is a significant difference between the means serum AFP level in both smokers and tombak users and control group, p=0.0045 and p=0.0049 respectively. T 13.2%of the tombak users and 23.5% of smokers have had serum AFP levels more than upper limit of the normal range (0-3-28 Ku/1) serum CEA level in control group ranged from 0 to 5.28 μg/1. The mean serum CEA levels of the tombak users and smokers was not differ significantly from that of the control group (p>0.05). But 12.7% of the tombak users and 14.7 of the smokers have had CEA level more than the upper limit of that of control. The relation between the duration of smoking and the level of CEA and AFP as well as the effect of age of subjects on the level of these analyte were studied. The results show no significant correlations where p>0.05

  20. A study on the CEA and AFP in serum of toombak users and smokers in Sudan using immunoradiometric assays

    International Nuclear Information System (INIS)

    Abdalla, O.M.; Hassan, A.M; Shabo, N.M.; Khalid, M.M.; El-amin, A.M.; Ali, N.I.

    2003-01-01

    Approximately 24% of the Sudanese population use toombak as smokeless tobacco. Tobacco specific N-nitro compounds have been detected at high concentration in toombak. this study focused on the possible carcinogenicity of those compounds through the measurement of serum CEA and serum AFP in both toombak users and smokers. 180 subjects were involved with the average age of 32 years ranging from 20 to 60 years. These 160 subjects were categorized into 3 groups (control, smokers, and toombak users). Serum CEA and AFP were measured using an IRMA technique. The mean AFP level in the control, toombak users and smokers group were 0.94, 1.98 and 2.34 Ku/l respectively. There is a significant difference between the means of serum AFP level in both smokers and toombak users and control group, p=0.0045 and p=0.0049 respectively. 13.2% of the toombak users and 23.5% of smokers have had serum AFP levels more than the upper limit of the normal range (0-3.28 Ku/l). Serum CEA level in control group ranged from 0 to 5.28μg/l. The mean serum CEA levels of the toombak users and smokers was not differ significantly from that of the control group (p>0.05). but 12.7% of the toombak users and 14.7 of the smokers have had CEA level more than the upper limit of that of control. The relation between the duration of smoking and the level of CEA and AFP as well as the effect of age of subjects on the level of these analyte were studied> The results show no significant correlations where p>0.05. (Author)

  1. Clinical significance of measurement of changes serum SE-CAD, CEA and CA19-9 contents after operation in patients with gastric cancer

    International Nuclear Information System (INIS)

    Jin Wentao; Jin Zeqiu; Jiang Hui

    2007-01-01

    Objective: To explore the clinical significance of changes of serum SE-CAD, CEA and CA19-9 levels in patients with gastric cancer after operation. Methods: Serum levels of soluble E-Cadherin were measured with ELISA and serum CEA, CA19 -9 levels measared with RIA in 32 patients with gastric cancer both before and 6 months after operation as well as in 30 controls. Results: Serum SE-CAD, CEA and CA19-9 levels were significantly higher in the patients than those in the controls before operation (P 0.05). Conclusion: Changes of serum SE-CAD, CEA and CA19-9 levels after operation might be prognostic importance in patients with gastric cancer. (authors)

  2. CEA SMAD 2016 Digitizer Evaluation.

    Energy Technology Data Exchange (ETDEWEB)

    Merchant, Bion J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    Sandia National Laboratories has tested and evaluated an updated SMAD digitizer, developed by the French Alternative Energies and Atomic Energy Commission (CEA). The SMAD digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The SMAD digitizers have been updated since their last evaluation by Sandia to improve their performance when recording at a sample rate of 20 Hz for infrasound applications and 100 Hz for hydro-acoustic seismic stations. This evaluation focuses primarily on the 20 Hz and 100 Hz sample rates. The SMAD digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

  3. History of enrichment research at the CEA

    International Nuclear Information System (INIS)

    Camarcat, N.

    1996-01-01

    French researches about uranium enrichment have been carried out at the CEA for about 40 years. In the beginning, these researches were considered as marginal and were carried out by a small team from the Powders Central Laboratory. They became intensive since 1955 and culminated in 1967 with the conception of Pierrelatte's factory. Several processes were studied: the gaseous diffusion, the chemical treatments, the centrifugation, the laser and electromagnetic separation processes on atomic and molecular vapors. Only a few of them were fully developed. This paper summarizes the development of these different processes in their historical context. (J.S.). 1 fig

  4. Status of Cea spallation modules for ads

    International Nuclear Information System (INIS)

    Enderle, R.; Poitevin, Y.; Deffain, J.P.; Bergeron, J.

    2001-01-01

    In the framework of CEA studies on ADS dedicated to waste transmutation, a liquid metal reference concept and an alternative solid target have been evaluated to produce neutrons inside the spallation module. This work examines the design (neutronic, thermohydraulic and mechanical aspects) and the performances of both options. It is shown that a liquid Pb-Bi target offers more possibilities regarding to high protons current densities (possible industrial extrapolation) but that a solid target made with tungsten particles offers also interesting ability to create a neutrons flux appropriated (strong spectrum and flat axial distribution) to an sub-critical core dedicated to incineration. (author)

  5. Nanotechnologies et Génie Civil, comment coopérer pour innover ?

    OpenAIRE

    LEBENTAL, Bérengère

    2010-01-01

    On discute la gestion de projet innovant à partir de l'exemple du projet Nanosonar, un projet de coopération entre le CEA-LETI et le LCPC visant au développement de nanocapteur innovant pour le suivi de durabilité en génie civil.

  6. Prognostic value of CEA and CA 19-9 tumor markers combined with cytology from peritoneal fluid in colorectal cancer.

    Science.gov (United States)

    Lee, In Kyu; Kim, Do Hyoung; Gorden, D Lee; Lee, Yoon Suk; Sung, Na Young; Park, Gyeoung-Sin; Kim, Hyung Jin; Kang, Won Kyung; Park, Jong Kyung; Ahn, Chang Hyeok; Kim, Jun-Gi; Jeon, Hae Myung; Oh, Seong Taek

    2009-04-01

    Early diagnosis and management of peritoneal metastases from colorectal cancer patients are difficult clinical challenges. The aims of this study were to evaluate the clinical significance of tumor markers and cytology in peritoneal effusions (PE) and peritoneal irrigation fluid (PI) and to determine their value as prognostic indicators in this disease. Two hundred thirty-four consecutive patients who underwent abdominal surgery for colorectal cancer from January 2006 to December 2007 were included, and tumor markers and cytology in PE and PI were analyzed prospectively. The incidence of free cancer cells retrieved from peritoneal samples was 7.9%. Cytology was positive in 40.0% by Papanicolaou and Giemsa staining, 73.3% by hematoxylin and eosin staining of cell blocks, and 66.7% by carcinoembryonic antigen (CEA) and calretinin immunohistochemistry. Multivariate analysis revealed that peritoneal CEA and cancer antigen (CA) 19-9 in PI were correlated with peritoneal metastasis and cytology. Level of peritoneal fluid CEA was statistically significantly correlated with recurrence and peritoneal metastatic recurrence in patients with negative peritoneal cytology. Cytology, peritoneal CEA, and peritoneal CA 19-9 showed correlations with cancer-free survival and overall survival. These correlations demonstrate the importance of continuous follow-up of peritoneal metastasis if there is positive cytology or an increase in CEA and CA 19-9 in peritoneal fluid.

  7. Detection of shock-heated hydrogen peroxide (H2O2) by off-axis cavity-enhanced absorption spectroscopy (OA-CEAS)

    KAUST Repository

    Alquaity, Awad

    2017-11-11

    Cavity-enhanced absorption spectroscopy (CEAS) is a promising technique for studying chemical reactions due to its desirable characteristics of high sensitivity and fast time-response by virtue of the increased path length and relatively short photon residence time inside the cavity. Off-axis CEAS (OA-CEAS) is particularly suited for the shock tube applications as it is insensitive to slight misalignments, and cavity noise is suppressed due to non-overlapping multiple reflections of the probe beam inside the cavity. Here, OA-CEAS is demonstrated in the mid-IR region at 1310.068 cm−1 to monitor trace concentrations of hydrogen peroxide (H2O2). This particular probe frequency was chosen to minimize interference from other species prevalent in combustion systems and in the atmosphere. The noise-equivalent detection limit is found to be 3.25 × 10−5 cm−1, and the gain factor of the cavity is 131. This corresponds to a detection limit of 74 ppm of H2O2 at typical high-temperature combustion conditions (1200 K and 1 atm) and 12 ppm of H2O2 at ambient conditions (296 K and 1 atm). To our knowledge, this is the first successful application of the OA-CEAS technique to detect H2O2 which is vital species in combustion and atmospheric science.

  8. Detection of shock-heated hydrogen peroxide (H2O2) by off-axis cavity-enhanced absorption spectroscopy (OA-CEAS)

    KAUST Repository

    Alquaity, Awad; KC, Utsav; Popov, Alber; Farooq, Aamir

    2017-01-01

    Cavity-enhanced absorption spectroscopy (CEAS) is a promising technique for studying chemical reactions due to its desirable characteristics of high sensitivity and fast time-response by virtue of the increased path length and relatively short photon residence time inside the cavity. Off-axis CEAS (OA-CEAS) is particularly suited for the shock tube applications as it is insensitive to slight misalignments, and cavity noise is suppressed due to non-overlapping multiple reflections of the probe beam inside the cavity. Here, OA-CEAS is demonstrated in the mid-IR region at 1310.068 cm−1 to monitor trace concentrations of hydrogen peroxide (H2O2). This particular probe frequency was chosen to minimize interference from other species prevalent in combustion systems and in the atmosphere. The noise-equivalent detection limit is found to be 3.25 × 10−5 cm−1, and the gain factor of the cavity is 131. This corresponds to a detection limit of 74 ppm of H2O2 at typical high-temperature combustion conditions (1200 K and 1 atm) and 12 ppm of H2O2 at ambient conditions (296 K and 1 atm). To our knowledge, this is the first successful application of the OA-CEAS technique to detect H2O2 which is vital species in combustion and atmospheric science.

  9. 2007-2008 activity report of the Association EURATOM-CEA (Executive summary)

    International Nuclear Information System (INIS)

    Labasse, F.

    2008-01-01

    This document is the executive summary of the full report, summarizing activities performed by EURATOM-CEA association in 2007-2008. The activities are various and have involved different issues like the study of dust generation processes and measurement techniques, ICRH antenna design for heating, integration studies inside the port-plug for diagnostics and in-situ divertor thermography, or the helium cooled lithium lead (HCLL) breeding blanket concept. Activities have been made to study the properties of the line defects governing the plastic behavior of iron base materials. Different options have been investigated for the superconducting magnet system. The measurement of in-vessel tritium inventory by laser induced breakdown spectroscopy (LIBS) technique has been investigated. 2007-2008 were also dedicated to the manufacture and complete tests of the AIA (Articulated Inspection Arm). AIA is designed to inspect divertor cassettes and the vacuum vessel first wall. Activities based on safety analysis or tests of ITER safety open issues have been carried out using several CEA facilities and expertise

  10. L’Association du personnel, le TREF, le Comité des Finances et le Conseil du CERN

    CERN Multimedia

    Staff Association

    2016-01-01

    L’Association du personnel, forte de son approche participative et consensuelle, recherche toujours le meilleur accord possible pour l’Organisation et son personnel. Pour ce faire, discussions et concertation avec la Direction, travail d’explication et de persuasion au TREF et ailleurs auprès des délégués des États membres sont nos principaux atouts. TREF (Tripartite Employment Conditions Forum), un Forum d’échanges, de discussions « L’objectif du Forum est d’améliorer le processus de prise de décision  en donnant aux personnes concernées la possibilité et le temps de comprendre pleinement la position de tous les participants. » (CERN/RTG/8) Le Forum tripartite sur les conditions d’emploi (TREF), créé par le Conseil du CERN en juin 1994, est composé de r...

  11. Elevated levels of serum tumor markers CA 15-3 and CEA are prognostic factors for diagnosis of metastatic breast cancers.

    Science.gov (United States)

    Lee, Jun Sang; Park, Seho; Park, Ji Min; Cho, Jung Hoon; Kim, Seung Il; Park, Byeong-Woo

    2013-10-01

    To investigate the prognostic value of tumor markers, cancer antigen 15-3 (CA 15-3) and carcinoembryonic antigen (CEA) levels at diagnosis of systemic recurrence. After primary treatments of locoregional breast cancers, serum CA 15-3 and/or CEA concentrations were regularly measured, and systemic recurrences were identified in 351 patients between January 1999 and December 2009. The association between tumor marker levels at systemic recurrence and survival were investigated by univariate and multivariate analyses. Elevated CA 15-3 and CEA levels were identified in 194 of 349 (55.6 %) and 111 of 308 (36.0 %) patients, respectively, at diagnosis of systemic recurrence. Elevated levels of CA 15-3 and CEA were correlated with visceral or multiple recurrences and elevated preoperative levels. Elevation of CA 15-3 was more prominent in younger patients and in primary node-positive tumors, while CEA was elevated in older patients at diagnosis and in estrogen receptor (ER)-positive tumors. Elevated tumor markers as well as ER negativity, short disease-free interval, and advanced stage at initial diagnosis showed independent prognostic significance on multivariate analysis. Among 306 patients for whom levels of both tumor markers at recurrence were available, 106 patients without elevation of either marker showed significantly better overall survival than those with elevated levels of either one or both markers, and the significance persisted in multivariate analysis. Elevated serum CA 15-3 and CEA levels at recurrence suggest increased tumor burden and may be prognostic for survival for metastatic breast cancer patients.

  12. INVESTIR DANS LE SAVOIR : le soutien que le CRDI consent à des ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    5 nov. 2010 ... ... 40 ans, le Cenre de recherches pour le développement international (CRDI), en plus d'appuyer des travaux de recherche dans l'ensemble des pays en développement, encourage des générations successives de jeunes chercheurs par l'entremise de son Programme de formation et de bourses (PFB).

  13. [A case of brain metastasis discovered after surgery for lung cancer based on changes in CEA, in which long-term survival was obtained by repeated gammaknife irradiation].

    Science.gov (United States)

    Kakeya, Hiroshi; Inoue, Yuichi; Sawai, Toyomitsu; Ikuta, Yasushi; Ohno, Hideaki; Yanagihara, Katsunori; Higashiyama, Yasuhito; Miyazaki, Yoshitsugu; Soda, Hiroshi; Tashiro, Takayoshi; Kohno, Shigeru

    2005-12-01

    A 58-year-old man underwent right lower lobectomy for lung adenocarcinoma in June 1998. Since a high level of tumor marker CEA persisted after surgery, chemotherapy was additionally performed, and the CEA level subsequently normalized. However, the CEA level increased in April 1999, and brain metastasis was found in the left occipital lobe, and the first gammaknife irradiation was performed. Multiple brain metastases were found when CEA increased again in August 1999, and the second gammaknife irradiation was performed. Moreover, brain metastases were found in the left frontal and occipital lobes in February 2000, and the third gammaknife irradiation was performed. CEA normalized thereafter, but increased in February 2001. Brain metastasis was found in the right occipital lobe, and the fourth gammaknife irradiation was performed. CEA has remained within the normal range for about 4 years thereafter. Long-term survival was possible by repeated gammaknife irradiation for brain metastases. Monitoring of CEA played an important role in finding recurrent brain metastasis in this patient.

  14. Sensitivity of CA 15-3, CEA and serum HER2 in the early detection of recurrence of breast cancer

    DEFF Research Database (Denmark)

    Eriksen, Ann Christina; Sørensen, Patricia Diana; Jacobsen, Erik Hugger

    2013-01-01

    The aim of this project was to investigate the sensitivity of CA 15-3, CEA and HER2 in the early diagnosis of metastatic breast cancer.......The aim of this project was to investigate the sensitivity of CA 15-3, CEA and HER2 in the early diagnosis of metastatic breast cancer....

  15. Situation 2002: release monitoring and surveillance of environment of Cea centers; Bilan 2002: controle des rejets et surveillance de l'environnement des centres CEA

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-07-01

    This publication renders an account of the situation of the releases of liquid and gaseous radioactive effluents, for the year 2002, as well as the radioactivity levels measured in the vicinity of Cea centers through the systematic surveillance of atmosphere, waters, vegetation and milk. An analysis on five years allows to follow their evolution. (N.C.)

  16. Contribution of the C.E.A. to standardization of nuclear plant equipments

    International Nuclear Information System (INIS)

    Dumax, P.; Seran, R.

    1980-01-01

    In research and production laboratories working in the nuclear field standardization of equipments greatly improves the profits of the installation and the protection of individuals and goods. The standardization effort on technical equipments of shielding, handling, detection and safety (so called P.M.D.S.) initiated by the C.E.A. in 1967 is being carried out now within the Institute of Protection and Nuclear Safety (I.P.S.N.) by a technical Service specialized in protection and dosimetry (S.T.E.P.D.). Its purpose is to establish standardization documents for internal use and to take part in the work of official standardization organizations. The benefits of standardization are reviewed. The achievements of the various working groups common to C.E.A. centers are stated and the documents published or to be published are listed [fr

  17. Utility of CEA and CA 19-9 tumor markers in diagnosis and prognostic assessment of mucinous epithelial cancers of the appendix.

    Science.gov (United States)

    Carmignani, C Pablo; Hampton, Regina; Sugarbaker, Christina E; Chang, David; Sugarbaker, Paul H

    2004-09-15

    Tumor markers are a clinical tool frequently used in oncology in association with other clinical and radiologic information. For gastrointestinal cancer, carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA 19-9) tumor markers have found selected clinical application. The use of these tumor markers in mucinous epithelial tumors of the appendix has not been previously determined. In patients with peritoneal dissemination of a mucinous epithelial malignancy of the appendix, tumor markers CEA and CA 19-9 were prospectively recorded preoperatively within 1 week prior to definitive treatment. Also, if the appendiceal tumor recurred, the tumor marker was determined. The accuracy of these two tumor markers in the management of this disease was determined for these two specific clinical situations. CEA was elevated in 56% of 532 patients and CA 19-9 was elevated in 67.1% of these patients. Although the absolute level of tumor marker did not correlate with prognosis, a normal value indicated an improved survival. CEA was elevated in 35.2% of 110 patients determined to have recurrent disease; CA 19-9 was elevated in 62.9% and at least one of the tumor markers was elevated in 68.2% of patients. An elevated CEA tumor marker at the time of recurrence indicated a reduced prognosis. Both CEA and CA 19-9 tumor markers were elevated in a majority of these patients and should be a valuable diagnostic tool previously underutilized in this group of patients. These tumor markers were also of benefit in the assessment of prognosis in that a normal level indicated an improved prognosis. At the time of a reoperative procedure, CEA and CA 19-9 tumor markers gave information regarding the progression of disease. These tumor markers have practical value in the management of epithelial appendiceal malignancy with peritoneal dissemination. Copyright 2004 Wiley-Liss, Inc.

  18. Le nouveau modèle africain | IDRC - International Development ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    22 juil. 2011 ... L'annulation de la dette, un commerce plus équitable, davantage d'aide : voilà le plan d'action mondial dont on convient qu'il faut de toute urgence mettre en oeuvre en vue d'accélérer le développement en Afrique. Or, ce serait rater le bateau que de ne pas s'engager dans la voie tout autre que les ...

  19. Improvements on Low Level Activity Gamma Measurements and X-ray Spectrometry at the CEA-MADERE Measurement Platform

    OpenAIRE

    Sergeyeva Victoria; Domergue Christophe; Destouches Christophe; Girard Jean Michel; Philibert Hervé; Bonora Jonathan; Thiollay Nicolas; Lyoussi Abdallah

    2016-01-01

    The CEA MADERE platform (Measurement Applied to DosimEtry in REactors) is a part of the Instrumentation Sensors and Dosimetry Laboratory (LDCI). This facility is dedicated to the specific activity measurements of solid and radioactive samples using Gamma and X-ray spectrometry. MADERE is a high-performance facility devoted to neutron dosimetry for experimental programs performed in CEA and for the irradiation surveillance programmes of PWR vessels. The MADERE platform is engaged in a continuo...

  20. Clinical usefulness of CEA, CA19-9, and CYFRA 21-1 as tumor markers for urothelial bladder carcinoma.

    Science.gov (United States)

    Washino, Satoshi; Hirai, Masaru; Matsuzaki, Atsushi; Kobayashi, Yutaka

    2011-01-01

    To evaluate the usefulness of measuring serum CEA, CA19-9, and CYFRA 21-1 levels for the diagnosis and monitoring of bladder cancer. Serum levels of CEA, CA19-9, and CYFRA 21-1 were measured in 85 patients with bladder cancer. The absolute level of each marker and the positive rate were compared with the clinical stage and histological grade of the tumor. Changes of the markers were assessed in patients with or without disease progression, and the correlations between survival and positivity/negativity of these markers were also evaluated. A higher serum level of CYFRA 21-1 was significantly correlated with higher tumor stage (p CEA and CA19-9 levels did not differ significantly among each stage and grade. The CYFRA 21-1 level increased significantly along with disease progression (from 7.33 ± 13.3 to 55.9 ± 127 ng/ml, p marker of advanced- and high-grade urothelial carcinoma of the bladder. It is useful for monitoring this disease and for predicting the prognosis. In contrast, the clinical usefulness of CEA and CA19-9 as tumor markers was not demonstrated. Copyright © 2011 S. Karger AG, Basel.

  1. La lipogenèse chez le lapin. Importance pour le contrôle de la teneur en lipides de la viande

    OpenAIRE

    Gondret, Florence

    1999-01-01

    La teneur en lipides d’un tissu est la résultante de plusieurs flux métaboliques (dépôt, synthèse, utilisation). Cet article présente les principales caractéristiques de la synthèse des lipides chez le lapin, dans le muscle comparativement aux tissus adipeux visibles et au foie. Le potentiel de synthèse de novo exprimé par le muscle augmente avec l’âge de l’animal, en parallèle à l’accumulation des triglycérides dans les adipocytes intramusculaires. L’activité des enzymes qui fournissent le N...

  2. Actinides exposure: review of Ca-DTPA injections inside Cea-Cogema plants

    International Nuclear Information System (INIS)

    Grappin, L.; Berard, P.; Beau, P.; Carbone, L.; Castagnet, X.; Courtay, C.; Le Goff, J.P.; Menetrier, F.; Neron, M.; Piechowski, J.

    2006-01-01

    Ca-DTPA has been used for medical treatment of plutonium and americium contaminations in the CEA and COGEMA plants from 1970 to 2003. This report is a survey of the injections administered of Ca-DTPA as a chelating molecule. This report will be a part of the AMM process for Ca-DTPA by intravenous administration submitted by the Central Pharmacy of the french Army. Out of 1158 injections administered to 469 persons, 548 events of possible or confirmed contaminations were reported. These employees were followed by occupational physicians according to the current regulations. The first part of the report is a synthesis of the most recent findings. Due to its short biological period and its limited action in the blood, Ca-DTPA does not chelate with plutonium and americium as soon as these elements are deposited in the target organs. It justifies an early treatment, even in cases of suspected contamination followed by additional injections if necessary. The second part presents data concerning these 1158 injections (way of contamination, posology, adverse effects...). These incidents took place at work, were most often minor, not requiring follow-up treatment. A study concerning the effectiveness of the product was done on a group of people having received 5 or more injections. These results were compared with effectiveness estimated from theoretical basis. Posologies and therapeutic schemes were proposed based on these observations. Additional studies are needed to confirm these findings. This document is the first synthesis in this field. It is the result of a collective work having mobilized the occupational medicine departments, the laboratories of CEA and COGEMA and a working group CEA-COGEMA-SPRA. (authors)

  3. Comparison of results of radioimmunoassay performed with nationwide different commercial kits for AFP, CEA, β2-m and TSH

    International Nuclear Information System (INIS)

    Sun Youxiang; Xu Ligen; Jiao Yan; Yang Wenbao; Wei Zekun; Sun Yanmin

    2005-01-01

    Objective: Study on an external quality assessment program with national quality control sera as standard for the comparison of the radioimmunoassay results obtained with different kits for AFP, CEA, β 2 -m and TSH. Methods: National quality control sera as well as pooled 'unknown' clinical sera specimens were assigned to the national laboratory and different manufacturers' laboratories (n=13) to be assayed for AFP, CEA, β 2 -m and TSH and the results cross-checked. Results: With CEA, the coefficient variation (CV) of different sets (n=7) assayed in the national and manufacturers' laboratories ranged from 10-30%; with β 2 -m, the CV ranged 10-20% (sets n=7); with AFP, CV ranged 15% ± (n=6). The above data suggested fairly good comparability and reproducibility. However, the results were less satisfactory with TSH assays (CV 20-40%, n=7). Conclusion: Present study revealed fairly satisfactory quality with CEA, β 2 -m and AFP kits. With TSH kits, the comparability was less satisfactory; the clinical normal ranges in different laboratories should be individualized and internal quality control enforced. (authors)

  4. Fluorescently labeled chimeric anti-CEA antibody improves detection and resection of human colon cancer in a patient-derived orthotopic xenograft (PDOX) nude mouse model.

    Science.gov (United States)

    Metildi, Cristina A; Kaushal, Sharmeela; Luiken, George A; Talamini, Mark A; Hoffman, Robert M; Bouvet, Michael

    2014-04-01

    The aim of this study was to evaluate a new fluorescently labeled chimeric anti-CEA antibody for improved detection and resection of colon cancer. Frozen tumor and normal human tissue samples were stained with chimeric and mouse antibody-fluorophore conjugates for comparison. Mice with patient-derived orthotopic xenografts (PDOX) of colon cancer underwent fluorescence-guided surgery (FGS) or bright-light surgery (BLS) 24 hr after tail vein injection of fluorophore-conjugated chimeric anti-CEA antibody. Resection completeness was assessed using postoperative images. Mice were followed for 6 months for recurrence. The fluorophore conjugation efficiency (dye/mole ratio) improved from 3-4 to >5.5 with the chimeric CEA antibody compared to mouse anti-CEA antibody. CEA-expressing tumors labeled with chimeric CEA antibody provided a brighter fluorescence signal on frozen human tumor tissues (P = 0.046) and demonstrated consistently lower fluorescence signals in normal human tissues compared to mouse antibody. Chimeric CEA antibody accurately labeled PDOX colon cancer in nude mice, enabling improved detection of tumor margins for more effective FGS. The R0 resection rate increased from 86% to 96% with FGS compared to BLS. Improved conjugating efficiency and labeling with chimeric fluorophore-conjugated antibody resulted in better detection and resection of human colon cancer in an orthotopic mouse model. © 2013 Wiley Periodicals, Inc.

  5. Tumor markers CA19-9, CA242 and CEA in the diagnosis of pancreatic cancer: a meta-analysis.

    Science.gov (United States)

    Zhang, Yimin; Yang, Jun; Li, Hongjuan; Wu, Yihua; Zhang, Honghe; Chen, Wenhu

    2015-01-01

    Pancreatic cancer has the worst prognosis and early detection is crucial for improving patient prognosis. Therefore, we performed a meta-analysis to evaluate and compare the sensitivity and specificity of single test of CA19-9, CA242, and CEA, as well as combination test in pancreatic cancer detection. We searched PubMed, Embase, Medline, and Wanfang databases for studies that evaluated the diagnostic validity of CA19-9, CA242, and CEA between January 1990 and September 2014. Data were analyzed by Meta-Disc and STATA software. A total of 21 studies including 3497 participants, which fulfilled the inclusion criteria were considered for analysis. The pooled sensitivities for CA19-9, CA242, and CEA were 75.4 (95% CI: 73.4-77.4), 67.8 (95% CI: 65.5-70), and 39.5 (95% CI: 37.3-41.7), respectively. The pooled specificities of CA19-9, CA242, and CEA were 77.6 (95% CI: 75.4-79.7), 83 (95% CI: 81-85), and 81.3 (95% CI: 79.3-83.2), respectively. Parallel combination of CA19-9+CA242 has a higher sensitivity (89, 95% CI: 80-95) without impairing the specificity (75, 95% CI: 67-82). Our meta-analysis showed that CA242 and CA19-9 have better performance in the diagnosis of pancreatic cancer than CEA. Furthermore, parallel combination test of CA19-9+CA242 could be of better diagnostic value than individual CA242 or CA19-9 test.

  6. The concentration of CYFRA 21-1, NSE and CEA in cerebro-spinal fluid can be useful indicators for diagnosis of meningeal carcinomatosis of lung cancer.

    Science.gov (United States)

    Wang, Peng; Piao, Yingzhe; Zhang, Xiaohui; Li, Wenliang; Hao, Xishan

    2013-01-01

    We aimed to investigate the concentration of CYFRA 21-1, NSE and CEA in cerebro-spinal fluid (CSF) and to explore their clinical value in the meningeal carcinomatosis (MC) of lung cancer. So that, sensitive and specificity of CSF examination can be improved in the initial diagnosis of MC. A total of 35 lung cancer patients and 35 patients with benign brain tumor in the same period enrolled in this study. The concentrations of tumor markers CEA, CYFRA 21-1 and NSE in CSF and peripheral blood were examined. The concentrations of three tumor markers of CYFRA 21-1, NSE and CEA in blood serum and CSF were obviously higher than that of benign disease group. In MC patients, the concentrations of three tumor markers of CYFRA 21-1, NSE and CEA in blood serum were significant lower than that in CSF. The maximum of Youden's index was identified as the cutoff value of indicator of MC in three tumor markers in CSF which were CEA > 4.7 μg/L, NSE > 14.6 μg/L and CYFRA21-1 > 5.5 μg/L respectively. Based on the cutoff values, the CEA had the highest sensitivity while the CYFRA21-1 had the highest specificitiy. Three tumor markers in the CSF had higher positive rate than those in blood serum. We combined the levels of CEA, NSE and CYFRA21-1 in CSF to diagnosis of MC. Positive of CEA or CYFRA21-1 had the greatest sensitivity of 100% while the specificity of 91.4%; the positive of both CEA and CYFRA21-1 had the highest specificity of 100% while the sensitivity of 74.3%. Both positive predictive value and negative predictive value were 100% when combination positive were confirmed when the all three markers were positive. The combination of CEA and CYFRA21-1 can be recommended in early screening of meningeal carcinoma. Especially, for the patient who was difficult to be diagnosed by CSF histology and MRI, it will be a useful auxiliary marker in diagnosis of MC. The combination of CEA, NSE and CYFRA21-1 can be an effective clinically confirmation and exclusively diagnose indictor of

  7. The dismantling of nuclear installations: The dismantling of nuclear installations at the CEA's Directorate for nuclear energy; The CEA's sanitation and dismantling works: example of one of the Marcoule UP1 program lots; Research and innovation in sanitation-dismantling; Global optimisation of the management of dismantling radioactive wastes

    International Nuclear Information System (INIS)

    Hauet, Jean-Pierre; Piketty, Laurence; Moitrier, Cyril; Blanchard, Samuel; Soulabaille, Yves; Georges, Christine; Dutzer, Michel; Legee, Frederic

    2016-01-01

    This publication proposes a set of four articles which addresses issues related to the dismantling of nuclear installations in France, notably for the different involved actors such as the CEA and the ANDRA. The authors more particularly address the issue and the general strategy of dismantling within the Directorate for nuclear energy of the CEA; comment the example of one of the Marcoule UP1 program lots to highlight sanitation and dismantling works performed by the CEA; discuss current research and innovation activities within the CEA regarding sanitation and dismantling; and comment how to globally optimise the management of radioactive wastes produced by dismantling activities

  8. Fast reactor physics at CEA: present studies and future prospects

    International Nuclear Information System (INIS)

    Hammer, P.

    1980-09-01

    This paper aims at giving a general survey of the fast reactor core physics and shielding studies wich are in progress at CEA (1979-1983) in order to solve the neutronic problems related to: - core design optimization, - reactor operation and fuel management, - safety, for the development of fast commercial breeders in France after the SUPER-PHENIX 1 construction is achieved

  9. Some activities at CEA related to behaviour of core internals

    International Nuclear Information System (INIS)

    Petrequin, P.

    1998-01-01

    Eighteen transparencies where presented, elaborating some activities at CEA related to behaviour of core internals. After some introduction, ten of the transparencies are essentially a copy of the table of contents of the AMES report no. 11 (report no: EUR 17694 EN). The remaining 6 foils concerned themselves with irradiation experiments in test reactors, namely the IDAHO, CASIMIR and ALEXANDRA experiments

  10. Rapport financier trimestriel pour le trimestre qui a pris fin le 31

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    31 déc. 2015 ... Le CRDI finance des travaux de recherche appliquée ... recherches pour le développement international (CRDI, le Centre) et ..... voie de développement et sur la mise en oeuvre des connaissances scientifiques, techniques et autres en .... Les accords expirent à des dates différentes, et le dernier prend fin.

  11. Rapport financier trimestriel pour le trimestre qui a pris fin le 30

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    30 sept. 2015 ... Le CRDI finance des travaux de recherche appliquée ... recherches pour le développement international (le Centre) et de ..... voie de développement et sur la mise en oeuvre des connaissances scientifiques, techniques et autres en .... Les accords expirent à des dates différentes, et le dernier prend fin en.

  12. Le modèle spatial de la capitale allemande

    Directory of Open Access Journals (Sweden)

    Antoine Laporte

    2013-06-01

    Full Text Available En Allemagne, en 1999, le Chancelier fédéral et son gouvernement ont quitté Bonn pour Berlin. Ce transfert du pouvoir est accompagné de celui d’une grande partie de l’appareil d’État et de la haute administration, et des fonctions qui leur sont traditionnellement attribuées comme la presse, les lobbys ou encore la diplomatie. Le déplacement du statut de capitale effective de l’Allemagne de Bonn à Berlin est le résultat des évolutions géopolitiques d’un pays ayant recouvré son unité et sa pleine et entière souveraineté. Installer le pouvoir exécutif et législatif à Berlin était une démarche hautement symbolique, visant à normaliser la position de l’ancienne capitale de la RDA et du IIIe Reich comme véritable centre politique de l’Allemagne. Or le déplacement des institutions fédérales n’est pas qu’un acte symbolique. Il entraîne également à l’échelle intra-urbaine des dynamiques très concrètes sur le tissu urbain et participe à la mise en place de nouvelles centralités dans la ville. En effet, le statut de capitale d’État prédestine l’agglomération à la coprésence de nombreuses fonctions urbaines spécifiques plus ou moins directement liées à l’exercice ou à la symbolique du pouvoir.

  13. An illustration of how sciences may be combined at Cea: parallel progress in superconductivity, particle physics, medical imaging and fusion

    International Nuclear Information System (INIS)

    Duchateau, J.L.; Devred, A.; Kircher, F.; Meuris, Ch.; Schild, Th.; Rousset, B.

    2005-01-01

    Superconductivity was hailed as the most important achievement of modern physics when it was discovered in 1911. Since then the enthusiasm has damped a bit because superconductivity still requires very low temperatures. This article gives an historical account of the application of superconductivity to the research programs and achievement of Cea (French atomic energy board). The first uses were dedicated to the design of superconducting magnets. We can note the delivery in 1989 of 246 quadrupolar magnets for bending particle beams for the HERA accelerator. As for the LHC (large hadron collider) project, Cea-Grenoble has a key role in the development of the cryogenic system and Cea-Saclay is responsible of the design of 400 quadrupolar magnets, it will have to fabricate 3 prototypes and the mass production will be made in Germany. A second sector involving superconductivity is thermonuclear devices through magnetic confinement. Tore-Supra has been for 10 years the only big fusion machine involving a superconducting system. In ITER all the coils necessary to the plasma confinement will be superconducting, it will represent 700 tons of superconducting wires. The research programs linked to the ITER project have led to the design of a new superconducting material: the niobium-tin (Nb 3 Sn). A third sector is medical imaging in which Cea is involved since the eighties. Cea-Saclay will home the Neurospin center whose purpose is to assess the limit of brain imaging from mice to man. Cea has to design magnets in the range of 11 tesla with a one meter broad clearance, the selected technology is that of superconducting magnets cooled by pressurized superfluid helium. (A.C.)

  14. Pre-radiotherapy and post-radiotherapy serial serum Squamous Cell Carcinoma antigen (SCC) and CarcinoEmbryonic Antigen (CEA) in the monitoring of squamous cell carcinoma of uterine cervix

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Hyong Geun; Park, Choong Hak [College of Medicine, Dankook Univ., Chunan (Korea, Republic of)

    1999-03-01

    To evaluate the significance of squamous cell carcinoma antigen (SCC) and carcinoembryonic antigen (CEA) as tumor markers in uterine cervix carcinoma. In 22 patients with histologically proven primary squamous cell carcinoma of uterine cervix, tumor volume was checked either by using MRI (in 20 patients) or ultrasound (in 2 patients). Pre-treatment serum SCC levels were checked in 22 patients and CEA levels in 21 patients. After curative radiotherapy, post-treatment SCC and CEA were checked regularly. SCC was raised in 68.2% and CEA was raised in 19.0% before treatment. The coefficient of correlation between tumor volume and pre-reatment SCC was 0.59382 when one extremely deviated case was excluded. And there was no correlation between tumor volume and CEA. After the treatment, SCC was raised in 9.1% and CEA was raised in 4.8%. In further follow up measurement, raise of SCC was associated with clinical relapse or persistence of disease. The specificity of raised SCC level in association with recurrent or persistent disease was 93.8%. The sensitivity in association with recurrent or persistent disease was 100%. The positive predictive values was 85.7%. The median lead time for recurrence was 1.2 months. Both SCC and CEA were good tumor markers for monitoring treatment effect in patients with raised pre-treatment levels. But the sensitivity of pretreatment CEA was low, while that of pretreatment SCC was high. And there was no additional gain by adding CEA measurements to SCC measurements.

  15. Pre-radiotherapy and post-radiotherapy serial serum Squamous Cell Carcinoma antigen (SCC) and CarcinoEmbryonic Antigen (CEA) in the monitoring of squamous cell carcinoma of uterine cervix

    International Nuclear Information System (INIS)

    Yun, Hyong Geun; Park, Choong Hak

    1999-01-01

    To evaluate the significance of squamous cell carcinoma antigen (SCC) and carcinoembryonic antigen (CEA) as tumor markers in uterine cervix carcinoma. In 22 patients with histologically proven primary squamous cell carcinoma of uterine cervix, tumor volume was checked either by using MRI (in 20 patients) or ultrasound (in 2 patients). Pre-treatment serum SCC levels were checked in 22 patients and CEA levels in 21 patients. After curative radiotherapy, post-treatment SCC and CEA were checked regularly. SCC was raised in 68.2% and CEA was raised in 19.0% before treatment. The coefficient of correlation between tumor volume and pre-reatment SCC was 0.59382 when one extremely deviated case was excluded. And there was no correlation between tumor volume and CEA. After the treatment, SCC was raised in 9.1% and CEA was raised in 4.8%. In further follow up measurement, raise of SCC was associated with clinical relapse or persistence of disease. The specificity of raised SCC level in association with recurrent or persistent disease was 93.8%. The sensitivity in association with recurrent or persistent disease was 100%. The positive predictive values was 85.7%. The median lead time for recurrence was 1.2 months. Both SCC and CEA were good tumor markers for monitoring treatment effect in patients with raised pre-treatment levels. But the sensitivity of pretreatment CEA was low, while that of pretreatment SCC was high. And there was no additional gain by adding CEA measurements to SCC measurements

  16. Serum levels of LDH, CEA, and CA19-9 have prognostic roles on survival in patients with metastatic pancreatic cancer receiving gemcitabine-based chemotherapy.

    Science.gov (United States)

    Tas, Faruk; Karabulut, Senem; Ciftci, Rumeysa; Sen, Fatma; Sakar, Burak; Disci, Rian; Duranyildiz, Derya

    2014-06-01

    Serum LDH, CEA, and CA19-9 levels are important tumor markers in pancreatic cancer. The purpose of this study was to evaluate the clinical significance of serum LDH, CEA, and CA19-9 levels in metastatic pancreatic cancer (MPC) receiving gemcitabine-based chemotherapy. In this retrospective study, we analyzed the outcome of 196 MPC patients who are treated with gemcitabine-based chemotherapy in our clinic. Positivity rates of serum LDH, CEA, and CA19-9 were 22, 40, and 83 %, respectively. Likewise, the rates of very high serum levels of tumor markers were correlated with these positivity rates (9 % for LDH, 30 % for CEA, and 55 % for CA19-9). The serum LDH levels were significantly higher in older patients (p = 0.05) and also in the patients with large tumors (p = 0.05), hepatic metastasis (p = 0.01), hypoalbuminemia (p = 0.01), and unresponsive to chemotherapy (p = 0.04). However, no correlation was found between both serum CEA and CA19-9 levels and possible prognostic factors (p > 0.05). The significant relationships were found between the serum levels of CEA and CA19-9 (r s = 0.24, p = 0.004), and serum LDH and CEA (r(s) = 0.193, p = 0.02). But, there was no correlation between serum LDH and CA19-9 levels (p = 0.39). One-year overall survival rate was 12.8 % (95 % CI 8-18). Increased serum levels of all the tumor markers significantly had adverse affect on survival (p = 0.001 for LDH, p = 0.002 for CEA, and p = 0.007 for CA19-9). However, no difference was observed in between high levels and very high levels of serum markers for all tumor markers (p > 0.05). Patients with normal serum levels of all three tumor markers had better outcome than others (p = 0.002) and those with normal serum LDH and CEA levels (whatever CA19-9) levels had associated with better survival compared with other possible alternatives (p CEA, and CA19-9 had significant affect on survival in MPC patients.

  17. Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19 - 9

    International Nuclear Information System (INIS)

    Jang, Dae Hwan; Choi, Duck Joo; Lee, Bum Woo; Park, Won; Han, Chang Soon; Kim, Hak San; Kim, Chong Soon

    1988-01-01

    The cocktails of two 131 I labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F(ab') 2 +Anti CEA F(ab') 2 fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach (2) and pancreas (l) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100%. One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summarized as follows: 1) The use of cocktails of CEA and CA 19-9 MCAB F(ab') 2 increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivity and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessary when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, F(ab') 2 fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

  18. Les femmes dans le secteur du travail domestique et le secteur ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Ce projet vise à rectifier le tir en faisant la lumière sur les caractéristiques ... le secteur du travail domestique et dans le secteur bancaire modifient la nature du travail ... des sciences sociales, des sciences humaines, de la santé publique ou.

  19. Clinical diagnostic significance of combined detection of serum and pleural effusion levels of CEA, NSE, CYFRA21-1, SCC-Ag in patients with lung cancer

    International Nuclear Information System (INIS)

    Bian Baoxiang; Hu Nan; Wu Fenglei; Yang Chengxi

    2008-01-01

    Objective: To appraise the clinical diagnostic significance of combined detection of serum and chest fluid levels of CEA, NSE, CYFRA21-1 and SCC-Ag in patients with lung cancer. Methods: Serum and pleural effusion contents of CEA, NSE, CYFRA21-1 and SCC-Ag were determined with RIA in 54 patients with lung cancer and 35 patients with benign lung disorders. Results: The serum and pleural effusion contents of CEA, NSE, CYFRA21-1 and SCC-Ag in patients with lung cancer were significantly higher than those in patients with benign lung disorders (P<0.01). The contents of CEA, NSE, CYFRA21-1 and SCC-Ag in patients pleural effusion were significantly higher than those in patients serum (P<0.01). For combined detection of CEA, NSE, CYFRA21-1 and SCC-Ag in serum and pleural effusion, the positive rate was 83.33% and 92.59% respectively. Conclusion: Combined detection of CEA, NSE, CYFRA21-1 and SCC-Ag contents in serum and pleural effusion can increase the positive rate of lung cancer diagnosis. (authors)

  20. Clinical significance of LUNX mRNA, CK19 mRNA, CEA mRNA expression in detecting micrometastasis from lung cancer

    International Nuclear Information System (INIS)

    Zhu Guangying; Liu Delin; Chen Jie

    2003-01-01

    Objective: To evaluate the sensitivity, specificity and clinical significance of CK19 mRNA, CEA mRNA and LUNX mRNA for detecting micrometastasis by sampling the peripheral blood and regional lymph nodes of lung cancer patients. Methods: Reverse transcriptase chain reaction (RT-PCR) was used to detect LUNX mRNA, CK19 mRNA, CEA mRNA for micrometastasis by sampling the peripheral blood of 48 lung cancer patients and 44 regional lymph nodes of such patients treated by curative resection. Peripheral blood of 30 patients with pulmonary benign lesions and 10 normal healthy volunteers and lymph nodes of 6 patients with benign pulmonary diseases served as control. Results: 1) LUNX mRNA, CK19 mRNA, CEA mRNA were expressed in all (35/35) lung cancer tissues. 2) In the peripheral blood from 48 lung cancer patients, 30 (62.5%) were positive for LUNX mRNA, 24 (50.0%) positive for CK19 mRNA and 32(66.7%) positive for CEA mRNA. The positive detection rates of micrometastasis in 44 lymph nodes from lung cancer patients were 36.4% (16 out of 44) for LUNX mRNA, 27.3% (12 out of 44) for CK19 mRNA and 40.9% (18 out of 44) for CEA mRNA. 3) In the 30 blood samples from patients with pulmonary benign diseases, 2 (6.7%) expressed CK19 mRNA, but none expressed LUNX mRNA or CEA mRNA. All the 3 molecular markers were negative in the 10 blood samples from healthy volunteers. In 11 lymph nodes from patients with pulmonary benign lesions, none was positive for any of the three markers. 4) In 44 regional lymph nodes from lung cancer patients, 6 (13.6%) were positive for metastasis by histopathological examination, with a positive rate significantly lower than that of the RT-PCR (P<0.05). 5) The micrometastatic positive rate in the peripheral blood of 40 non-small cell lung cancer (NSCLC) patients was significantly related to TNM stage (P=0.01). Conclusions: LUNX mRNA, CK19 MRNA, CEA mRNA are all appropriate target genes for the detection of micrometastasis from lung cancer. LUNX mRNA and CEA m

  1. Le Conseil des gouverneurs | CRDI - Centre de recherches pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le Conseil des gouverneurs guide le travail du CRDI en lui fournissant une orientation stratégique, en examinant ses activités et en approuvant ses budgets. Les gouverneurs – un maximum de 14 – sont nommés par le gouverneur en conseil du Canada pour un mandat d'au plus quatre ans, qui peut être reconduit. La Loi ...

  2. Le FIVB annonce le financement de cinq autres projets | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    10 avr. 2018 ... En partenariat avec la Fondation Bill et Melinda Gates et Affaires mondiales Canada, le CRDI est heureux d'annoncer la prochaine série de projets soutenus par le Fonds d'innovation en matière de vaccins pour le bétail (FIVB). À ce jour, 11 projets ont obtenu un financement total de 13,6 millions de CAD ...

  3. CEA contribution to power plant operation with high burnup level

    International Nuclear Information System (INIS)

    1981-03-01

    High level burnup in PWR leads to investigate again the choices carried out in the field of fuel management. French CEA has studied the economic importance of reshuffling technique, cycle length, discharge burnup, and non-operation period between two cycles. Power plants operators wish to work with increased length cycles of 18 months instead of 12. That leads to control problems because the core reactivity cannot be controlled with the only soluble boron: moderator temperature coefficient must be negative. With such cycles, it is necessary to use burnable poisons and for economic reasons with a low penalty in end of cycle. CEA has studied the use of Gd 2 O 3 mixed with fuel or with inert element like Al 2 O 3 . Parametric studies of specific weights, efficacities relatively to the fuel burnup and the fuel enrichment have been carried out. Particular studies of 1 month cycles with Gd 2 O 3 have shown the possibility to control power distribution with a very low reactivity penalty in EOC. In the same time, in the 100 MW PWR-CAP, control reactivity has been made with large use of gadolinia in parallel with soluble boron for the two first cycles

  4. On 28 April, CERN welcomed Jean-Claude Petit, director of programmes of the Commissariat á l'Energie Atomique (CEA) in France, and Olivier Pagezy, finance director of the CEA.

    CERN Multimedia

    Maximilien Brice

    2005-01-01

    They visited the assembly hall for the CMS experiment, the COMPASS experiment and the test facilities for the LHC magnets. They are pictured (no 01) in the ATLAS cavern with Peter Jenni, ATLAS spokesman, and Gabriele Fioni, CEA deputy director of programmes

  5. Démocratie et le développement dans le monde arabe | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le Rapport sur le développement humain dans le monde arabe 2002 souligne un " déficit en matière de libertés " fondamental dans le monde arabe se traduisant dans toute la région par des régimes autoritaires et la faiblesse de la démocratie. Cette subvention permettra aux chercheurs Samir Makdisi et Ibrahim Elbadawi ...

  6. Le nouveau modèle africain | CRDI - Centre de recherches pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    22 juil. 2011 ... Or, ce serait rater le bateau que de ne pas s'engager dans la voie tout autre que les Africains proposent maintenant — à savoir se défaire du syndrome de la dépendance qui afflige l'Afrique depuis des décennies. Le Canada et les autres pays riches du Nord reconnaissent généralement qu'ils ne peuvent ...

  7. Le facteur humain et la sûreté de fonctionnement dans le ...

    African Journals Online (AJOL)

    Notre contribution porte sur lele fondamental du facteur humain dans le management intégré des risques d'une part et du rôle déterminant qu'il peut avoir à jouer pour que la sûreté de fonctionnement réponde à sa propriété d'autre part. Un rôle illustré à travers une analyse de risque dans un complexe de Gaz Naturel ...

  8. The possible role of tumor antigen CA 15-3, CEA and ferritin in malignant and benign disease

    OpenAIRE

    Nafija Serdarević; Samira Mehanović

    2012-01-01

    Introduction: Serum CA15-3 has been one of the most reliable tumor markers used in monitoring of breast cancer patients. To increase its sensitivity, the combined measurement of other tumor markers (CEA and ferritin) with CA15-3 was investigated. The aim of this study was determination of CA 15-3, CEA and ferritin in female patients with breast cancer, lung cancer and mastitisMethods: 300 patients with carcinoma, hospitalized at Department of Gynecologic Oncology and Department for Oncology a...

  9. Le corps sportif1

    OpenAIRE

    Brulé, Pierre

    2015-01-01

    Le nu et le cuit Si, pas plus que l’Auvergne, le monde grec antique n’a été le théâtre d’un quelconque « miracle », il n’a pas manqué, toutefois, de « distinctions » diverses, d’exceptions même, qui le singularisent absolument. Une, c’est la pédérastie. Quelle culture l’a autant valorisée, autant instrumentalisée, l’a autant érigée en modèle ? Nous n’en avons pas encore mesuré toutes les conséquences. La place inhabituelle que prend là et alors cette polyvalence rare de la libido masculine de...

  10. CEA engineering studies and integration of the ITER diagnostic port plugs

    International Nuclear Information System (INIS)

    Doceul, L.; Walker, C.; Ingesson, C.; Ciattaglia, E.; Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C.

    2007-01-01

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel

  11. CEA engineering studies and integration of the ITER diagnostic port plugs

    Energy Technology Data Exchange (ETDEWEB)

    Doceul, L. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)], E-mail: louis.doceul@cea.fr; Walker, C. [ITER International Team, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Ingesson, C.; Ciattaglia, E. [EFDA CSU - Garching, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)

    2007-10-15

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel.

  12. Memoirs of a Cea veteran

    Energy Technology Data Exchange (ETDEWEB)

    Puill, A

    2001-07-01

    A brief account is given of the way in which nuclear energy has developed in France and elsewhere over the last fifty years: options developed by the French Atomic Energy Commission (CEA), naval propulsion, development of pressurised water reactors, MOX and thorium fuels. Afterwards, the prospectives for the 21. century will be discussed. Considering that natural resources are depleting while releases of both greenhouse gases and world population are increasing, an active energy policy will have to be implemented with due consideration for social equity and solidarity. It is in this context that the developed countries will have to give preference, beyond savings, to renewable sources of energy, including of course, nuclear energy. Nuclear energy can continue to develop in the long term, provided fast breeder technology is developed at some point. As far as transport is concerned, hydrogen technology, which is clean and renewable, is promising, provided it is generated by nuclear energy. (author)

  13. Memoirs of a Cea veteran

    International Nuclear Information System (INIS)

    Puill, A.

    2001-01-01

    A brief account is given of the way in which nuclear energy has developed in France and elsewhere over the last fifty years: options developed by the French Atomic Energy Commission (CEA), naval propulsion, development of pressurised water reactors, MOX and thorium fuels. Afterwards, the prospectives for the 21. century will be discussed. Considering that natural resources are depleting while releases of both greenhouse gases and world population are increasing, an active energy policy will have to be implemented with due consideration for social equity and solidarity. It is in this context that the developed countries will have to give preference, beyond savings, to renewable sources of energy, including of course, nuclear energy. Nuclear energy can continue to develop in the long term, provided fast breeder technology is developed at some point. As far as transport is concerned, hydrogen technology, which is clean and renewable, is promising, provided it is generated by nuclear energy. (author)

  14. Chemoradiation-induced changes in serum CEA and plasma TIMP-1 in patients with locally advanced rectal cancer

    DEFF Research Database (Denmark)

    Aldulaymi, Bahir; Christensen, Ib J; Sölétormos, György

    2010-01-01

    BACKGROUND: Preoperative biomarkers serum CEA and plasma TIMP-1 have been shown to have prognostic and predictive value in patients with colorectal cancer. The aim of the present study was to evaluate the possible impact of chemoradiotherapy (CRT) on preoperative biomarker levels in patients...... with rectal cancer. PATIENTS AND METHODS: Thirty-three patients with rectal cancer were prospectively included. The patients received CRT for 6-8 weeks. Blood samples were collected before CRT (pre-CRT) and preoperatively (post-CRT). RESULTS: Median CEA was 3.5 (range 0.6-36.1) µg/l and 2.4 (range 0.......0-10.2) µg/l (p=0.002) and median plasma TIMP-1 was 132.1 (range 77.8-342.7) µg/l and 140.0 (range 82.6-440.9) µg/l (p=0.04) in the pre- and post-CRT measurements, respectively. CONCLUSION: CRT induced a significant decrease in serum CEA and increase in plasma TIMP-1 levels. Therefore, the preoperative...

  15. Hyperloop : le droit et le devoir de douter...

    OpenAIRE

    Crozet , Yves

    2016-01-01

    National audience; C’est comme si c’était fait ! Les journaux les plus sérieux (Les Echos) nous annoncent que le premier test du prototype Hyperloop dans le désert du Nevada est un succès. Le projet futuriste d’Elon Musk se concrétise. Un véhicule terrestre de transport collectif va bientôt se déplacer à plus de 1000 km/h entre San Francisco et Los Angeles. Comme pour donner du crédit à cette information, la SNCF, via sa filiale SYSTRA va devenir partenaire du projet. Déjà les journaux de Pro...

  16. LE LIEN ENTRE FINANCE ET ECONOMIE ISLAMIQUES VIA LE MODELE PRINCIPIEL "ZR"

    OpenAIRE

    BELABES, ABDERRAZAK

    2010-01-01

    A l'heure où certains évoquent l'intégration de la finance islamique à la finance globale, et d'autres rattachent la finance islamique à des thèmes en vogue telles que la finance éthique, la finance participative ou la finance socialement responsable, le présent papier explore le lien entre finance et économie islamiques à partir du modèle principiel "ZR", c’est-à-dire "Zakât" et "Ribâ". Ce modèle montre que les principes invariants de Zakât et Ribâ jouent un rôle central dans l’établissement...

  17. Assessment of CA 15.3, CEA and TPA concentrations during monitoring of breast cancer

    DEFF Research Database (Denmark)

    Sölétormos, G; Petersen, P H; Dombernowsky, P

    2000-01-01

    The variability of the tumor markers cancer antigen (CA) 15.3, carcinoembryonic antigen (CEA) and tissue polypeptide antigen (TPA) during steady state concentrations and the rate of increase during progression is described. One hundred and ninety-two patients were monitored during first...... with above cutoff level values. Clinical and marker progression was registered for 75 (CA 15.3), 62 (CEA), and 57 (TPA) patients. The coefficients of total variation of steady state concentrations (comprising the intra- and interassay analytical imprecision and the within subject biological variation) were...... for TPA (0.0346). Our data indicate that criteria for assessment of sequential tumor marker concentrations should consider the marker in question, the steady state variability, the cutoff value, and the rate of increase during disease progression....

  18. Situation 2002: release monitoring and surveillance of environment of Cea centers

    International Nuclear Information System (INIS)

    2003-07-01

    This publication renders an account of the situation of the releases of liquid and gaseous radioactive effluents, for the year 2002, as well as the radioactivity levels measured in the vicinity of Cea centers through the systematic surveillance of atmosphere, waters, vegetation and milk. An analysis on five years allows to follow their evolution. (N.C.)

  19. Le Kenya nomme le titulaire de sa première chaire de recherche

    International Development Research Centre (IDRC) Digital Library (Canada)

    14 avr. 2016 ... De concert avec le CRDI, la National Commission for Science, Technology and Innovation (NACOSTI) du Kenya a inauguré sa première chaire de recherche à Nairobi, le 31 mars 2015. Le professeur Fabian Omoding Esamai, qui dirige actuellement le College of Health Sciences de la Moi University, a été ...

  20. pour le trimestre qui a pris fin le 31 décembre 2014

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    31 déc. 2014 ... Le CRDI finance des travaux de recherche appliquée ... recherches pour le développement international (le Centre) et de ...... voie de développement et sur la mise en oeuvre des connaissances scientifiques, techniques et autres en vue .... Les accords expirent à des dates différentes, et le dernier prend fin.

  1. Le cru, le cuit et le pourri dans _Le vice-consul_ de Marguerite Duras

    Directory of Open Access Journals (Sweden)

    Hélène Caron

    2011-05-01

    Full Text Available Bien que plusieurs articles critiques aient déjà avancé de nouvelles perspectives sur le texte Le Vice-Consul (LVC de Marguerite Duras, l’analyse de la représentation de la nourriture dans ce roman n’a fait l’objet d’aucune étude. Cet article tente donc de combler cette lacune en proposant d’analyser les images du cru et du cuit, images qui se rejoignent sous les notions du pourri et de l’abject, tout en offrant quelques interprétations de l’un des passages critiques du roman où la folle mendiante croque la tête d’un poisson vivant.

  2. Le Peer to Peer: Vers un Nouveau Modèle de Civilization

    Directory of Open Access Journals (Sweden)

    Michel Bauwens

    2006-06-01

    Full Text Available Le « peer to peer » est la dynamique intersubjective caractéristique des réseaux distribués. Le but de cet essai est de montrer qu'il s'agit d'une véritable nouvelle forme d’organisation sociale, apte à produire et échanger des biens, à créer de la valeur. Celle-ci est la conséquence d'un nouvel imaginaire social, et possède le potentiel de devenir le pilier d'un nouveau mode d'économie politique, voire d'un nouveau type de civilisation. Pour cela, nous allons d'abord définir le P2P, décrire en bref ces manifestations, et le différencier d'autres modalités d'échange intersubjectif tel que le marché, la hiérarchie, l'économie du don.Comme principale modalité P2P nous distinguons: Les processus de production P2P, comme troisième mode de production, qui n'est ni géré par un mode hiérarchique ou par l'état, ni répondant à des impératifs de profit ou qui sont modulés par le biais des prix. Les processus de gouvernance P2P, qui gouverne ces processus de production. Les formes de propriété P2P, qui sont destine a empecher l’appropriation prive de cette production pour le commun.Afin d’examiner les characteristiques de cette nouvelle dynamique sociale, nous utilisons la typologie intersubjective de l’anthropologue Alan Page Fisque, qui distingue: 1. l'échange égalitaire (Equality Matching, c..a.d l’economie du don. 2. La relation d’autorité (Authority Ranking tel qu’elle s’exprime dans le mode hierarchique. 3. le marché (Market Pricing. 4. la participation commune (Communal Shareholding.En conclusion, nous examinons les possibilites d’expansion de ce nouveau mode sociale et son insertion dans l’economie capitaliste, en nous nous posons la question: le P2P peut-il etre concu comme alternative sociale et economique aux modeles existants.

  3. Comparison between clinical significance of serum proinflammatory proteins (IL-6 and CRP) and classic tumor markers (CEA and CA 19-9) in gastric cancer.

    Science.gov (United States)

    Lukaszewicz-Zając, Marta; Mroczko, Barbara; Gryko, Mariusz; Kędra, Bogusław; Szmitkowski, Maciej

    2011-06-01

    Gastric cancer (GC) is a second most common cause of cancer-related death and represents an inflammation-driven malignancy. It has been suggested that interleukin 6 (IL-6) and C-reactive protein (CRP) play a potential role in the growth and progression of GC. The aim of the present study was to compare clinical significance of IL-6 and CRP with classic tumor markers-carcinoembryonic antigen (CEA) and carbohydrate antigen (CA 19-9) in GC patients. The study included 92 patients with GC and 70 healthy subjects. The serum concentrations of IL-6, CEA and CA 19-9 were determined using immunoenzyme assays, whereas CRP using immunoturbidimetric method. We defined the diagnostic criteria and prognostic value for proteins tested. In GC patients, the serum concentrations of all the proteins tested were significantly higher than in healthy subjects. The IL-6, CEA and CA 19-9 levels correlated with nodal metastases, while CRP with tumor stage, gastric wall invasion, presence of nodal and distant metastases. Diagnostic sensitivity of IL-6 was higher (85%) than those of other markers (CRP 66%, CA 19-9 34%, CEA 22%) and increased in combined use with CRP or CEA (88%). The area under ROC curve for IL-6 was larger than those of CRP and classic tumor markers (CEA and CA 19-9). None of the proteins tested was independent prognostic factor for the survival of GC patients. Our findings indicate better usefulness of serum proinflammatory proteins-IL-6 and CRP than classic tumor markers-CEA and CA 19-9 in the diagnosis of GC.

  4. Le « modèle germanique » Français

    OpenAIRE

    Lefebvre , Armelle

    2009-01-01

    Resume Le concept d?Allemagne permet de reveler, selon une approche , l?ampleur des desaccords ayant preside a la definition du concept d?Etat en France. De ce dernier, l?on aborde divers emplois qu?illustrent des modeles d?Etat. Le opere ainsi dans un debat qui est le creuset de la connaissance politique moderne, avec ses apories: celles de la souverainete externe, de l?ordre interetatique, de la confederation. L?article expose alo...

  5. Sodium boiling studies at the CEA state of the art

    International Nuclear Information System (INIS)

    Girard, C.; Grand, D.; Papin, J.; Seiler, J.M.

    1979-08-01

    A description of the general approach used by the CEA to solve sodium boiling problems provides an understanding of our philosophy for code development. From the review of the main results obtained in the out-of-pile experiments, CFNa and CESAR, we deduce the main hypothesis of our basic model of sodium boiling. Our best estimate and simplified codes are briefly described and their results are compared with the experiments

  6. Los Dioramas de Le Corbusier = Le Corbusier's Dioramas

    Directory of Open Access Journals (Sweden)

    José Ramón Alonso Pereira

    2013-10-01

    Full Text Available ResumenLe Corbusier simboliza el urbanismo moderno racional, cuyo esfuerzo riguroso de planificación exige un esfuerzo paralelo de comprensión. Se opone a ese urbanismo contemporáneo que quiere percibir y disfrutar la ciudad sensiblemente. Sentimiento y razón, sin embargo, no son opuestos y Le Corbusier nos dio en su momento las claves para intentar una síntesis, uniéndolos de modo singular por medio de sus ‘boîte à miracles’ o ‘cajas mágicas’: esos "espectáculos arquitectónicos de síntesis" que definiría en el Ciam de 1951. Pretendemos aproximarnos aquí a la primera de esos ‘espectáculos’: el ‘diorama’, viéndolo como estrategia corbuseriana de mediación entre lo racional y lo sensible en la ciudad moderna y contemporánea.Palabras claveLe Corbusier, diorama, Ville Contemporaine, Plan Voisin, Plan MaciáAbstractLe Corbusier symbolizes the modern rational urbanism, whose rigorous effort of town planning demands a parallel effort of comprehension. It opposes to these contemporary urbanism that wish to perceive and to enjoy cities in a sensible way. Nevertheless, sentiment and reason are not adverses and Le Corbusier gives us at his  moment keys to intent a synthesis, joined them in a singular way by means of his ‘boîtes à miracles’ or ‘magic boxes’: those "architectural spectacles of synthesis" that he defined in 1951 Ciam. Here we try to approach to the first of those ‘spectacles’: the ‘diorama’, considering it as a corbusean strategy of mediation between rational and sensible in modern and contemporary city.Key wordsLe Corbusier, diorama, Ville Contemporaine, Plan Voisin, Plan Maciá.

  7. Rapport financier trimestriel pour le trimestre qui a pris fin le 30

    International Development Research Centre (IDRC) Digital Library (Canada)

    Sophie Comeau

    30 sept. 2011 ... politiques, de chercheurs et de collectivités de par le monde. ..... Financement : le CRDI est visé par l'Examen stratégique et ... Le Conseil des gouverneurs a amorcé la planification du recrutement du nouveau président.

  8. CEA, SCC and NSE levels in exhaled breath condensate--possible markers for early detection of lung cancer.

    Science.gov (United States)

    Zou, Yingchang; Wang, Lin; Zhao, Cong; Hu, Yanjie; Xu, Shan; Ying, Kejing; Wang, Ping; Chen, Xing

    2013-12-01

    Lung cancer (LC) is the leading cause of cancer-related death. The sensitive and non-invasive diagnostic tools in the early stage are still poor. We present a pilot study on the early diagnosis of LC by detecting markers in exhaled breath condensate (EBC). EBC samples were collected from 105 patients with LC and 56 healthy controls. We applied chemiluminescence immunoassay to detect CEA (carcinoembryonic antigen), SCC (squamous cell carcinoma) antigen and NSE (neuron specific enolase) in EBC and serum. Concentrations of markers were compared between independent groups and subgroups. A significantly higher concentration level of each marker was found in patients with LC than healthy controls. The areas under curve of receiver operating characteristic (ROC) curves were 0.800, 0.771, 0.659, 0.679, 0.636 and 0.626 for EBC-CEA, serum-CEA, EBC-SCC, serum-SCC, EBC-NSE and serum-NSE, respectively. Markers in EBC had a higher positive rate (PR) and were more specific to histologic types than markers in serum. In addition, multivariate analysis was performed to evaluate the association of presenting markers with the stages of non-small cell lung cancer (NSCLC). EBC-CEA showed the best predictive characteristic (p tumor markers in EBC may have a better diagnostic performance for LC than those in serum. With further investigation on the combination of markers in EBC, detection of EBC could probably be a novel and non-invasive method to detect NSCLC earlier.

  9. Analogue studies at the french atomic commission (CEA)

    International Nuclear Information System (INIS)

    Petit, J.C.

    1986-06-01

    The different research activities of the French Atomic Energy Commission in the analogue study field are presented. Most of them are conducted in collaboration with major research organisations, both french and international. In fact, the scientific community has been associated to these programmes at different steps of their realisation. The brief description presented illustrates the great diversity and complementarity of actions conducted by CEA for better understanding, through the study of natural analogues, the basic processes that will rule the long term behaviour of high level radwaste materials in a repository and hence contributing to hopefully guaranty disposal safety

  10. Le Sanskrit

    CERN Document Server

    Balbir, Nalini

    2013-01-01

    Cet ouvrage est destiné à tous ceux qui souhaitent se mettre ou se remettre à l'étude du sanskrit et ne peuvent y consacrer que quelques minutes par jour. En suivant le principe de la méthode quotidienne Assimil, vous acquerrez progressivement le vocabulaire et la grammaire de base qui sont nécessaires à la lecture des textes de la littérature sanskrite classique. Vous trouverez dans cette méthode une approche vivante de la langue et de la culture sanskrite classique à travers des textes d'abord adaptés pour le débutant puis authentiques. En quelques mois, vous manierez la langue sans efforts ni hésitation, de manière très naturelle. Les enregistrements reprennent l'intégralité des textes en sanskrit des leçons et des exercices de traduction du livre. Ils sont interprétés, à un rythme progressif, par des locuteurs natifs professionnels.

  11. Combination of cyst fluid CEA and CA 125 is an accurate diagnostic tool for differentiating mucinous cystic neoplasms from intraductal papillary mucinous neoplasms.

    Science.gov (United States)

    Nagashio, Yoshikuni; Hijioka, Susumu; Mizuno, Nobumasa; Hara, Kazuo; Imaoka, Hiroshi; Bhatia, Vikram; Niwa, Yasumasa; Tajika, Masahiro; Tanaka, Tsutomu; Ishihara, Makoto; Shimizu, Yasuhiro; Hosoda, Waki; Yatabe, Yasushi; Yamao, Kenji

    2014-01-01

    Despite advances in imaging techniques, diagnosis and management of pancreatic cystic lesions still remains challenging. The objective of this study was to determine the utility of cyst fluid analysis (CEA, CA 19-9, CA 125, amylase, and cytology) in categorizing pancreatic cystic lesions, and in differentiating malignant from benign cystic lesions. A retrospective analysis of 68 patients with histologically and clinically confirmed cystic lesions was performed. Cyst fluid was obtained by surgical resection (n = 45) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) (n = 23). Cyst fluid tumor markers and amylase were measured and compared between the cyst types. Receiver operating characteristic (ROC) curve analysis of the tumor markers demonstrated that cyst fluid CEA provided the greatest area under ROC curve (AUC) (0.884) for differentiating mucinous versus non-mucinous cystic lesions. When a CEA cutoff value was set at 67.3 ng/ml, the sensitivity, specificity and accuracy for diagnosing mucinous cysts were 89.2%, 77.8%, and 84.4%, respectively. The combination of cyst fluid CEA content >67.3 ng/ml and cyst fluid CA 125 content >10.0 U/ml segregated 77.8% (14/18) of mucinous cystic neoplasms (MCNs) from other cyst subtypes. On the other hand, no fluid marker was useful for differentiating malignant versus benign cystic lesions. Although cytology (accuracy 83.3%) more accurately diagnosed malignant cysts than CEA (accuracy 65.6%), it lacked sensitivity (35.3%). Our results demonstrate that cyst fluid CEA can be a helpful marker in differentiating mucinous from non-mucinous, but not malignant from benign cystic lesions. A combined CEA and CA 125 approach may help segregate MCNs from IPMNs. Copyright © 2014 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  12. Progress of the BT-EdF-CEA project. The lithium polymer battery; Avancees du projet BT-EdF-CEA. Batterie lithium polymere

    Energy Technology Data Exchange (ETDEWEB)

    Marginedes, D.; Majastre, H. [Bollore Technologies, 29 - Quimper (France); Baudry, P.; Lascaud, S. [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Bloch, D.; Lebrun, N. [CEA Grenoble, CEREM, 38 (France)

    1996-12-31

    The lithium-polymer energy storage technology requires the production of thin films of huge surface. The BT-EdF-CEA consortium has studied the various manufacturing techniques of these films and their assembly. The process was chosen according to its productivity, low expensiveness, ecological impact and energy performances with capacities reaching 40 Ah. This paper explains: the objectives and specifications of the project, the advantage of the consortium and the role of the different partners, the results (coating, dry extrusion and battery element manufacturing techniques), and the electrochemical performances of the elements. (J.S.)

  13. Progress of the BT-EdF-CEA project. The lithium polymer battery; Avancees du projet BT-EdF-CEA. Batterie lithium polymere

    Energy Technology Data Exchange (ETDEWEB)

    Marginedes, D; Majastre, H [Bollore Technologies, 29 - Quimper (France); Baudry, P; Lascaud, S [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Bloch, D; Lebrun, N [CEA Grenoble, CEREM, 38 (France)

    1997-12-31

    The lithium-polymer energy storage technology requires the production of thin films of huge surface. The BT-EdF-CEA consortium has studied the various manufacturing techniques of these films and their assembly. The process was chosen according to its productivity, low expensiveness, ecological impact and energy performances with capacities reaching 40 Ah. This paper explains: the objectives and specifications of the project, the advantage of the consortium and the role of the different partners, the results (coating, dry extrusion and battery element manufacturing techniques), and the electrochemical performances of the elements. (J.S.)

  14. De quoi le genre est-il le nom ?

    OpenAIRE

    Andrieu, Bernard

    2013-01-01

    Cette note de lecture présente une courte évolution des travaux sur le genre sous l’angle du rapport au corps en démontrant comment la dénaturalisation du corps et du sexe biologique a conduit à une description culturaliste des fonctions individuelles et des rôles sociaux. Si le genre dénaturalise le corps c’est en refusant toute référence au sexe ou à la sexualité en tant qu’ils seraient des données naturelles. Depuis son apparition en 1947, sous la plume de John Money, psychologue chargé du...

  15. Le modèle fédéral dans le sport français, un principe fondateur dépassé ?

    Directory of Open Access Journals (Sweden)

    Béatrice Barbusse

    2009-06-01

    Full Text Available Dans le sport français, le fédéralisme s’est installé comme une évidence institutionnelle dès la fin du 19e siècle et le début du 20e siècle dans un pays qui pourtant ne se pense pas fédéral. En outre, si son apparition est liée à l’émergence du sport comme nouvelle pratique sociale à côté d’autres pratiques physiques plus traditionnelles, il s’est rapidement imposé comme la pierre angulaire de l’ordre sportif français. Près d’un siècle plus tard, son monopole institutionnel est bousculé voire «concurrencé». Ces constats d’ensemble nous amènent à nous interroger sur les raisons pour lesquelles le sport a épousé le modèle fédéral dans un pays non fédéral, mais aussi sur ses limites actuelles. Est-il encore le modèle approprié aux circonstances contemporaines ? A-t-il toujours sa place dans le système de gouvernance du sport ? Ou bien, a contrario, reste-t-il le dernier rempart légitime face aux excès du sport contemporain (dopage, violence, corruptions, déficits… ? À partir d’une approche socio-historique, il s’est agi dans cet article de reconstruire le fil de la généalogie du fédéralisme sportif tout en s’interrogeant sur ses perspectives. Au delà de la question du fédéralisme, c’est bien celle de la gouvernance du sport contemporain qui est posée.

  16. Le modèle judiciaire libéral mis à l’épreuve : la surveillance des juges sous le Directoire

    OpenAIRE

    Berger, Emmanuel

    2007-01-01

    La justice du Directoire est principalement identifiée aux différentes violations infligées par le gouvernement afin de contrôler le pouvoir judiciaire et durcir la répression criminelle. Cette représentation est, en réalité, partiale. L’auteur tente de le prouver à travers l’analyse d’un aspect essentiel du système judiciaire directorial : la surveillance des juges. L’étude des normes et des pratiques montre que le mode de surveillance établi par le code des délits et des peines respecte la ...

  17. Liver myeloid-derived suppressor cells expand in response to liver metastases in mice and inhibit the anti-tumor efficacy of anti-CEA CAR-T

    Science.gov (United States)

    Burga, Rachel A.; Thorn, Mitchell; Point, Gary R.; Guha, Prajna; Nguyen, Cang T.; Licata, Lauren A.; DeMatteo, Ronald P.; Ayala, Alfred; Espat, N. Joseph; Junghans, Richard P.; Katz, Steven C.

    2015-01-01

    Chimeric antigen receptor modified T cell (CAR-T) technology, a promising immunotherapeutic tool, has not been applied specifically to treat liver metastases (LM). While CAR-T delivery to LM can be optimized by regional intrahepatic infusion, we propose that liver CD11b+Gr-1+ myeloid-derived suppressor cells (L-MDSC) will inhibit the efficacy of CAR-T in the intrahepatic space. We studied anti-CEA CAR-T in a murine model of CEA+ LM and identified mechanisms through which L-MDSC expand and inhibit CAR-T function. We established CEA+ LM in mice and studied purified L-MDSC and responses to treatment with intrahepatic anti-CEA CAR-T infusions. L-MDSC expanded three-fold in response to LM and their expansion was dependent on GM-CSF, which was produced by tumor cells. L-MDSC utilized PD-L1 to suppress anti-tumor responses through engagement of PD-1 on CAR-T. GM-CSF, in cooperation with STAT3, promoted L-MDSC PD-L1 expression. CAR-T efficacy was rescued when mice received CAR-T in combination with MDSC depletion, GM-CSF neutralization to prevent MDSC expansion, or PD-L1 blockade. As L-MDSC suppressed anti-CEA CAR-T, infusion of anti-CEA CAR-T in tandem with agents targeting L-MDSC is a rational strategy for future clinical trials. PMID:25850344

  18. A combination of preoperative CT findings and postoperative serum CEA levels improves recurrence prediction for stage I lung adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yamazaki, Motohiko, E-mail: xackey2001@gmail.com [Department of Radiology, Niigata University Graduate School of Medical and Dental Sciences (Japan); Ishikawa, Hiroyuki [Department of Radiology, Niigata University Graduate School of Medical and Dental Sciences (Japan); Kunii, Ryosuke [Division of Cellular and Molecular Pathology, Niigata University Graduate School of Medical and Dental Sciences (Japan); Tasaki, Akiko; Sato, Suguru; Ikeda, Yohei; Yoshimura, Norihiko [Department of Radiology, Niigata University Graduate School of Medical and Dental Sciences (Japan); Hashimoto, Takehisa; Tsuchida, Masanori [Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences (Japan); Aoyama, Hidefumi [Department of Radiology, Niigata University Graduate School of Medical and Dental Sciences (Japan)

    2015-01-15

    Objectives: To assess the prognostic value of combined evaluation of preoperative CT findings and pre/postoperative serum carcinoembryonic antigen (CEA) levels for pathological stage I lung adenocarcinoma. Methods: This retrospective study included 250 consecutive patients who underwent complete resection for ≤3-cm pathological stage I (T1–2aN0M0) adenocarcinomas (132 men, 118 women; mean age, 67.8 years). Radiologists evaluated following CT findings: maximum tumor diameter, percentage of solid component (%solid), air bronchogram, spiculation, adjacency of bullae or interstitial pneumonia (IP) around the tumor, notch, and pleural indent. These CT findings, pre/postoperative CEA levels, age, gender, and Brinkman index were assessed by Cox proportional hazards model to determine the best prognostic model. Prognostic accuracy was examined using the area under the receiver operating characteristic curve (AUC). Results: Median follow-up period was 73.2 months. In multivariate analysis, high %solid, adjacency of bullae or IP around the tumor, and high postoperative CEA levels comprised the best combination for predicting recurrence (P < 0.05). A combination of these three findings had a greater accuracy in predicting 5-year disease-free survival than did %solid alone (AUC = 0.853 versus 0.792; P = 0.023), with a sensitivity of 85.7% and a specificity of 74.3% at the optimal threshold. The best cut-off values of %solid and postoperative CEA levels for predicting high-risk patients were ≥48% and ≥3.7 ng/mL, respectively. Conclusion: Compared to %solid alone, combined evaluation of %solid, adjacency of bullae or IP change around the tumor, and postoperative CEA levels improves recurrence prediction for stage I lung adenocarcinoma.

  19. le des universités dans le renforcement des technologies de l ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    le des universités dans le renforcement des technologies de l'information et de la communication au service du développement (TIC-D) en Asie. Jusqu'à maintenant, les efforts déployés dans le secteur de l'enseignement supérieur ont surtout été axés sur le téléapprentissage, l'apprentissage électronique et différentes ...

  20. Assessment of the diagnostic value of combined determination of serum CA199 CA125 and CEA in patients with cancer of pancreas

    International Nuclear Information System (INIS)

    Wu Congshan; Liu Xugui

    2005-01-01

    Objective: To assess the diagnostic value of combined determination of serum CA199, CA125 and CEA for cancer of pancreas. Methods: Serum CA199, CA125 and CEA levels were detected with CLIA in 32 patients with cancer of pancreas and 36 controls. Results: Positive detection rate of CA199 in patients with cancer of pancreas was 90.6% (29/32). Positive rate for CA125 and CEA was 65.6% (21/32) and 46.9% (15/32) respectively. With combined determination of these 3 tumor markers, the positive rate was 96.9% (31/32). The mean content of serum CA199 after successful operation (32.5±8.4U/ml) was significantly lower than that before operation (840.2 ± 102.5U/ml) (P<0.01). Conclusion: Combined determination of CA199, CA125 and CEA would improve the detection rate of cancer of pancreas and post-operative changes of CA199 could be of prognostic value. (authors)

  1. Le Mouvement Social

    OpenAIRE

    FRIDENSON, Patrick

    2003-01-01

    J'ai la faiblesse d'affirmer que parmi les revues françaises d'histoire Le Mouvement Social est la revue qui a publié le plus d'articles et de comptes rendus en matière d'histoire des femmes et du gender. Chacun peut le vérifier grâce à nos pages Web sur le site Internet du Dictionnaire créé par Jean Maitron. Elles comportent la table des matières complète de la revue depuis sa fondation en 1960. Notre rédaction est extrêmement fière de ce résultat. Mais elle reconnaît qu'il a été difficile à...

  2. Cancer mortality of nuclear workers of CEA and COGEMA from 1969 to 1986

    International Nuclear Information System (INIS)

    Tirmarche, M.; Raphalen, A.; Allin, F.; Le Guen, P.

    1992-01-01

    Cancer mortality of the nuclear workers of CEA and COGEMA has been collected by the occupational health services of both firms from 1969 to 1986. The data are related only to the workers who died when in activity. Only very few workers left CEA and COGEMA before retirement so we consider this mortality survey as describing correctly the cancer mortality for the age groups less than 60-65 years old. Compared to the national mortality of same sex, age and calendar period, by the method of indirect standardization, the only excess observed was in the female population, linked to breast cancer mortality. The male population demonstrated a high healthy worker effect, even for cancer mortality. This study has now to be completed by an typical epidemiological cohort study in order to test cancer mortality after retirement and to discuss a possible relation with occupational exposure. (author)

  3. Value and significance of tumor markers as CEA, CA125, SCC-Ag, CA199 and CYFRA21-1 in the diagnosis of cervical cancer

    Directory of Open Access Journals (Sweden)

    Xiao-Juan Wang

    2017-09-01

    Full Text Available Objective: To investigate the value and significance of serum CEA, CA125, SCC-Ag, CA199 and CYFRA21-1 in the diagnosis of cervical cancer by comparing the detection of five serum markers. Methods: A total of 108 cases were divided into three groups, including 60 cervical cancerpatients and 20 cervical intraepithelial neoplasiain patients treated in our hospital from September 2015 to September 2016 and 28 healthy women. Radioimmunoassay was used to detect and compare the serum levels of CA125, CA199, CYFRA21-1 and ELISA method was used to detect and compare the serum levels of SCC-Ag, CEA. Results: (1 There was no statistically significant difference in the serum CEA, CA125, SCC-Ag, CA199, CYFRA21-1 levels between CIN group and control group. The serums CEA, CA125, SCC-Ag, CA199, CYFRA21-1 levels of cervical cancer patients were significantly higher than the other two groups. The differences were statistically significant. (2There were statistically significant differences in the serum CEA, CA125, SCC-Ag, CA199, CYFRA21-1 levels between different cervical pathological type groups.The serum CA125, CA199, CEA levels of cervical glandular cancer patients were significantly higher than the other two groups. The differences were statistically significant. The serum SCC-Ag, CYFRA21-1 levels of cervical squamous cancer patients were significantly higher than the other two groups. The differences were statistically significant. Conclusion: The serums CEA, CA125, SCC-Ag, CA199, CYFRA21-1 levels of cervical cancer patients were significantly higher than cervical intraepithelial neoplasiain patients and healthy women. The serum CA125, CA199, CEA levels of cervical glandular cancer patients were significantly higher and the serum SCC-Ag, CYFRA21-1 levels of cervical squamous cancer patients were significantly higher. The five tumor markers can be used in diagnosis of cervical cancer and they are also worthy in distinguishing cervical pathological types.

  4. Isolation of scFv antibody fragments against HER2 and CEA tumor antigens from combinatorial antibody libraries derived from cancer patients.

    Science.gov (United States)

    Ayat, Hoda; Burrone, Oscar R; Sadghizadeh, Majid; Jahanzad, Eissa; Rastgou, Nasrin; Moghadasi, Sarrira; Arbabi, Mehdi

    2013-11-01

    Tumor cells expressing HER-2/neu and CEA antigens are potentially ideal targets for antibody-targeted therapy. In this study, two large human combinatorial libraries have been generated from the lymph nodes of breast cancer patients that express HER2 and CEA antigens in their tumors. These 'immune' libraries have been constructed in two different formats of scFv, differing in the length of the peptide linker connecting the two variable VH and VL domains. Libraries derived from these patients may contain a larger pool of anti-tumor antigen antibodies and are useful repertoire for isolating scFvs against any tumor markers. The results of this study showed that we were successful in obtaining human scFvs against HER-2/neu and CEA. For HER-2, cell-panning strategy was performed and resulted in two scFv binders that detected the complete HER-2 receptor on the cell membrane and internalized to the cells. Also, preliminary ELISA data showed that several anti-CEA scFv binders were isolated by panning. Copyright © 2013 The International Alliance for Biological Standardization. All rights reserved.

  5. Le faussaire roman

    CERN Document Server

    D'Anna, Gianfranco

    2016-01-01

    À l'aube du XXIe siècle, le monde de la science est sur le point de vivre une révolution. Le jeune physicien allemand Albert Hendrick Thebell, des célèbres laboratoires de recherche B-Labs, à Summit, dans le New Jersey, publie, dans les plus grandes revues scientifiques internationales, une série d'articles dans lesquels il prétend avoir obtenu des résultats extraordinaires qui pourraient révolutionner les bases mêmes de la technologie. Rapidement, la communauté scientifique puis les médias saluent en lui un futur prix Nobel; on compare même son génie à celui d'Albert Einstein. Le progrès scientifique semble avoir franchi une étape décisive, susceptible d'amener un futur meilleur. Mais ces découvertes sont-elles authentiques ? Car pendant ce temps, dans les mêmeslaboratoires, des voix s'élèvent pour contester non seulement les théories de Thebell mais aussi la légitimité même de ses expériences ; certains le soupçonnent d'avoir combiné la plus grande fraude scientifique de tous l...

  6. Digitization and valorization through the INIS database of an exceptional stock of grey literature documents: the 'historical' CEA reports (1948-1969)

    International Nuclear Information System (INIS)

    Surmont, J.; Brulet, C.; Brulet, M.; Pourny, M.; Constant, A.; Guille, N.; Le Blanc, A.; Mouffron, O.; Anguise, P.; Jouve, J.J.

    2008-01-01

    This poster, prepared for the sixth edition of the meetings of scientific and technical information professionals (RPIST, Nancy (France)), presents the joint CEA/IAEA project of digitization of the collection of reports published by the French atomic energy commission (CEA) between 1948 and 1969. This exceptional stock of about 2760 grey literature monographs covers the first 20 years of researches carried out at the CEA and has been entered in the INIS database with a link to the full text. The poster describes the different steps of the project from the selection of the documents, their digitization, and the preparation of the corresponding inputs. The INIS database and its general content are briefly presented. (J.S.)

  7. Lele du pharmacien dans la fécondation in vitro

    OpenAIRE

    Hannoun , Odélia

    2017-01-01

    La procréation médicalement assistée regroupe plusieurs techniques venant en aide aux couples ayant des difficultés à concevoir. Environ 15% des couples en age de procréer consultent pour une difficulté à concevoir. Ce véritable problème de société nous incite à réfléchir sur le role que tient le pharmacien en tant que professionnel de santé dans le parcours de fécondation in vitro. Le pharmacien développe une relation étroite avec les patients au comptoir. Il est la pour expliquer le traitem...

  8. Method comparison for determination of the tumor markers AFP, CEA, PSA and free PSA between Immulite 2000 XPI and Dimension Vista 1500.

    Science.gov (United States)

    Zur, Berndt; Holdenrieder, Stefan; Walgenbach-Brünagel, Gisela; Albers, Eike; Stoffel-Wagner, Birgit

    2012-01-01

    For the Luminescent Oxygen Channeling Immunoassay (LOCI) technology as established for Dimension Vista 1500, assays have been developed for the serum tumor markers AFP, CEA, PSA and free PSA. We performed a method analysis for these parameters using the Immulite 2000 XPI. Determination of within-day and total imprecision of the methods was carried out according to CLSI guidelines with three serum pools. In addition, parallel measurements were performed with both systems in 1,871 routine serum samples and correlations were calculated. Calculated total imprecision of the three serum pools for AFP was 3.8 - 4.3%, for CEA 3.3 - 4.3%, for tPSA 3.6 - 4.0% and for fPSA it was 3.5 - 8.2%. Correlations of these markers across the entire value range were very good with the following correlation coefficients: 0.997 for AFP, 0.996 for CEA, 0.971 for tPSA and 0.988 for fPSA. While values for AFP and tPSA from both methods were comparable (slopes 1.02 and 1.01), lower values were measured for CEA and fPSA with the Dimension Vista (slopes 0.83 and 0.91). For AFP, a sample cluster with considerably higher values than with Dimension Vista was observed in the lower measurement range (CEA, tPSA and fPSA, as developed with the LOCI technology for the Dimension Vista, show good comparability with results obtained from the Immulite 2000 XPI. However, lower measurement ranges for CEA and fPSA as well as individual divergences, especially with AFP, must be taken into consideration in the event of method changeover.

  9. High Plasma TIMP-1 and Serum CEA Levels during Combination Chemotherapy for Metastatic Colorectal Cancer Are Significantly Associated with Poor Outcome

    DEFF Research Database (Denmark)

    Aldulaymi, Bahir; Byström, Per; Berglund, Ake

    2010-01-01

    . The first response evaluation was performed after 8 weeks of chemotherapy. Results: Median plasma TIMP-1 and serum CEA levels did not change significantly during 6 weeks of treatment. High plasma TIMP-1 and high serum CEA levels before treatment and at weeks 2, 4 and 6 were related to poor objective...... associated with poor overall survival; p

  10. Le boson et le chapeau mexicain un nouveau grand récit de l'univers

    CERN Document Server

    Cohen-Tannoudji, Gilles

    2013-01-01

    Le boson ? C'est l'ultime particule élémentaire prédite par la théorie de l'infiniment petit, qui manquait encore et dont la découverte, grâce au grand collisionneur de hadrons du CERN, a été annoncée au monde entier le 4 juillet 2012. Postulée en 1964 par Robert Brout, François Englert et Peter Higgs, elle explique que le photon - particule qui transmet la force électromagnétique - n'a pas de masse, à l'encontre de celles véhiculant la force faible. Une telle dissymétrie était a priori incompatible avec la symétrie fondamentale, dite «de jauge», sur laquelle est fondé le modèle standard de la physique des particules. Le chapeau mexicain ? C'est le mécanisme grâce auquel le boson rend compte, en préservant les acquis du modèle standard, de l'origine des masses des particules élémentaires. Le boson et le chapeau mexicain se placent à la croisée - retracée par les deux auteurs en dialogue avec François Englert - des chemins de l'évolution des théories de l'astrophysique contemp...

  11. 2007-2008 activity report of the Association EURATOM-CEA (Full Report)

    International Nuclear Information System (INIS)

    Labasse, F.

    2009-01-01

    This document summarizes the activities performed by EURATOM-CEA association in 2007-2008. The activities are various and have involved different issues like the study of dust generation processes and measurement techniques, ICRH antenna design for heating, integration studies inside the port-plug for diagnostics and in-situ divertor thermography, or the helium cooled lithium lead (HCLL) breeding blanket concept. Activities have been made to study the properties of the line defects governing the plastic behavior of iron base materials. Different options have been investigated for the superconducting magnet system. The measurement of in-vessel tritium inventory by laser induced breakdown spectroscopy (LIBS) technique has been investigated. 2007-2008 were also dedicated to the manufacture and complete tests of the AIA (Articulated Inspection Arm). AIA is designed to inspect divertor cassettes and the vacuum vessel first wall. Activities based on safety analysis or tests of ITER safety open issues have been carried out using several CEA facilities and expertise. This document is divided into 5 sections: 1) physics integration, 2) in-vessel, 3) magnet system and cryogenics, 4) tritium breeding and materials, 5) safety and environment, 6) system studies, 7) design support and procurement, 8) JET technology

  12. Controlled power supply for isotopes separator; Alimentations regulees pour separateur d'isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Lavaitte, A; Pottier, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1953-07-01

    This equipment is destined to equip the separator of isotopes who is the subject of the CEA report n 138. It includes: - a controlled power supply in voltage. - a controlled power supply in current. The spectra of fluctuations of these assembly is different in the two cases. (authors) [French] Cet equipement est destine a equiper le separateur d'isotopes qui fait l'objet du rapport C.E.A. n 138. Il comprend: - une alimentation regulee en tension. - une alimentation regulee en courant. Le spectre de fluctuations de ces ensembles est different dans les deux cas. (auteurs)

  13. The Grenoble CEA Center: dismantled and rehabilitated

    International Nuclear Information System (INIS)

    Anon.

    2013-01-01

    The denuclearization program of the CEA center in Grenoble was launched in 2001. It involves 6 nuclear facilities (3 research reactors: Melusine, Siloette, and Siloe, and 1 laboratory (LAMA) and 2 units for processing wastes). The dismantling works were finished at the end of 2012 and the 2013 program concerns: the demolition of the buildings homing Melusine and Siloe reactors, the final rehabilitation of the Siloe raft, and the final rehabilitation of the laboratory and of the waste processing units. The budget is 117*10 6 euros for Siloe, 28*10 6 euros for Melusine, 6*10 6 euros for Siloette, 70*10 6 euros for the LAMA, and 90*10 6 euros for the 2 waste processing units. (A.C.)

  14. Clinical significance of combined detection of CYFRA21-1, NSE and CEA in classification and staging of patients with lung cancer

    International Nuclear Information System (INIS)

    Hu He; Li Yanhua; Liang Weida; Zhang Qin

    2011-01-01

    To explore clinical value of combined detection of CYFRA21-1, NSE and CEA in classification and staging of patients with lung cancer, the CYFRA21-1, NSE and CEA levels in pleural effusion in 330 patients with lung cancer and in 43 patients with benign were detected by the electrochemiluminescence. The results showed that CYFRA21-1, NSE and CEA levels in pleural effusion in patients with lung cancer group were significantly higher than that of in benign group (P<0.01). The positive rate of tumor markers in different pathological type lung cancer were different,which CYFRA21-1 positive rate in squamous cell cancer group was highest with 65.5%; CEA positive rate in glands cancer group was supreme with 65.0%; the NSE positive rate in differentiation cancer group was highest with 79.5%. The positive rate in three markers combined detection was higher than that in one item detection. The tumor marker levels in lung cancer were positively related with clinical staging. The higher of tumor marker levels and the more late of clinical staging, and the clinical III∼IV period was obviously higher than that I∼II period (P<0.05). The combined detection of CYFRA21-1, NSE and CEA may enhance the positive rate in lung cancer detection, and may have significant clinical value in the classification and staging of patients with lung cancer. (authors)

  15. Development activities on NIR large format MCT detectors for astrophysics and space science at CEA and SOFRADIR

    Science.gov (United States)

    Boulade, Olivier; Moreau, Vincent; Mulet, Patrick; Gravrand, Olivier; Cervera, Cyril; Zanatta, Jean-Paul; Castelein, Pierre; Guellec, Fabrice; Fièque, Bruno; Chorier, Philippe; Roumegoux, Julien

    2016-07-01

    CEA and SOFRADIR have been manufacturing and characterizing near infrared detectors in the frame of ESA's near infrared large format sensor array roadmap to develop a 2Kx2K large format low flux low noise device for space applications such as astrophysics. These detectors use HgCdTe as the absorbing material and p/n diode technology. The technological developments (photovoltaic technology, readout circuit, ...) are shared between CEA/LETI and SOFRADIR, both in Grenoble, while most of the performances are evaluated at CEA/IRFU in Saclay where a dedicated test facility has been developed, in particular to measure very low dark currents. The paper will present the current status of these developments at the end of ESA's NIRLFSA phase 2. The performances of the latest batch of devices meet or are very close to all the requirements (quantum efficiency, dark current, cross talk, readout noise, ...) even though a glow induced by the ROIC prevents the accurate measurement of the dark current. The current devices are fairly small, 640x512 15μm pixels, and the next phase of activity will target the development of a full size 2Kx2K detector. From the design and development, to the manufacturing and finally the testing, that type of detector requests a high level of mastering. An appropriate manufacturing and process chain compatible with such a size is needed at industrial level and results obtained with CEA technology coupled with Sofradir industrial experience and work on large dimension detector allow French actors to be confident to address this type of future missions.

  16. Producing energy without greenhouse effect gases: the CEA action

    International Nuclear Information System (INIS)

    2008-01-01

    Major actor in the domain of new energy technologies, the CEA manages the french research on the hydrogen and the fuel cells. It is also implied with INES (National Institute for the Solar Energy) in the photovoltaic and thermal solar. With the IFP (French Petroleum Institute), it manages research on biofuels. Of course the thermonuclear fusion, for the development of the energy of the future, is in its research program too. This information document presents the possibilities of these energies and the associated research programs. (A.L.B.)

  17. Upgrading of aerosol generators for use at Cadarache (CEA)

    International Nuclear Information System (INIS)

    Kaspar, G.; Loescher, H.; Ruhmann, H.

    1988-11-01

    The aerosol generators developed for, and used in, the DEMONA project have been further developed for the FUCHIA project run by CEA. As a result of these efforts the generators have been uprated for fifty-hour continuous generation of SnO 2 and CsOH aerosols at a rate of 10 g/min against a system pressure of 5 bar. Significantly higher feed rates may be possible but were not required. The development objective was fully satisfied, the generators are ready for service in the FUCHIA project. (orig.). 1 ref., 2 tabs., 9 figs [de

  18. Atualidades e perspectivas das Anonáceas no mundo

    OpenAIRE

    São José,Abel Rebouças; Pires,Mônica de Moura; Freitas,Afonso Lúcio Gomes Estrela de; Ribeiro,Denis Pereira; Perez,Luis Alfonso Aguilar

    2014-01-01

    Várias espécies da família Annonaceae produzem frutos comestíveis cultivados em pomares comerciais ou coletados de forma extrativista, em diversas partes do mundo. O gênero Annona possui elevado número de espécies nativas, no entanto poucas produzem frutos comestíveis. Algumas são cultivadas comercialmente, outras são obtidas de forma extrativista. As principais anonáceas cultivadas no mundo são: Annona muricata, Annona squamosa e Annona cherimola, com destaque também para a atemoia (híbrido ...

  19. Entre les violences conjugales et le harcèlement moral : le stalking .

    Directory of Open Access Journals (Sweden)

    Nicolas Desurmont

    2007-09-01

    Full Text Available Ce livre de la criminologue Murielle Anteo est le premier publié en langue française sur le stalking si l’on excepte les travaux encore inédits de Virginie Léon (2004. Comme le rappelle l’auteure, le terme est emprunté à l’anglais to stalk (hanter, rôder, et désigne un comportement menaçant, initié par un individu dont l’objectif conscient ou inconscient est l’objectivation de sa victime à des fins de domination. L’agression prend différentes formes : ...

  20. Le jeu de la création : Le mangeur (2005) de Ying Chen

    OpenAIRE

    Nicole Dunham

    2013-01-01

    Le théoricien James Hans définit le jeu comme une déconstruction structurante, un processus de perpétuelle remise en question. Dans Le Mangeur (2005) de Ying Chen, la narratrice revit un épisode d’une de ses vies passées où elle meurt mangée, avalée, par son père, descendant dans le « tunnel » du ventre de ce dernier. Cependant, suite à cet événement, elle se retrouve dans un autre espace-temps où elle rencontre son mari, A.. Une équivalence s’établit dans le roman entre les éléments suivants...

  1. Fully human IgG and IgM antibodies directed against the carcinoembryonic antigen (CEA Gold 4 epitope and designed for radioimmunotherapy (RIT of colorectal cancers

    Directory of Open Access Journals (Sweden)

    Pugnière Martine

    2004-10-01

    Full Text Available Abstract Background Human monoclonal antibodies (MAbs are needed for colon cancer radioimmunotherapy (RIT to allow for repeated injections. Carcinoembryonic antigen (CEA being the reference antigen for immunotargeting of these tumors, we developed human anti-CEA MAbs. Methods XenoMouse®-G2 animals were immunized with CEA. Among all the antibodies produced, two of them, VG-IgG2κ and VG-IgM, were selected for characterization in vitro in comparison with the human-mouse chimeric anti-CEA MAb X4 using flow cytometry, surface plasmon resonance, and binding to radiolabeled soluble CEA and in vivo in human colon carcinoma LS174T bearing nude mice. Results Flow cytometry analysis demonstrated binding of MAbs on CEA-expressing cells without any binding on NCA-expressing human granulocytes. In a competitive binding assay using five reference MAbs, directed against the five Gold CEA epitopes, VG-IgG2κ and VG-IgM were shown to be directed against the Gold 4 epitope. The affinities of purified VG-IgG2κ and VG-IgM were determined to be 0.19 ± 0.06 × 108 M-1 and 1.30 ± 0.06 × 108 M-1, respectively, as compared with 0.61 ± 0.05 × 108 M-1 for the reference MAb X4. In a soluble phase assay, the binding capacities of VG-IgG2κ and VG-IgM to soluble CEA were clearly lower than that of the control chimeric MAb X4. A human MAb concentration of about 10-7 M was needed to precipitate approximatively 1 ng 125I-rhCEA as compared with 10-9 M for MAb X4, suggesting a preferential binding of the human MAbs to solid phase CEA. In vivo, 24 h post-injection, 125I-VG-IgG2κ demonstrated a high tumor uptake (25.4 ± 7.3%ID/g, close to that of 131I-X4 (21.7 ± 7.2%ID/g. At 72 h post-injection, 125I-VG-IgG2κ was still concentrated in the tumor (28.4 ± 11.0%ID/g whereas the tumor concentration of 131I-X4 was significantly reduced (12.5 ± 4.8%ID/g. At no time after injection was there any accumulation of the radiolabeled MAbs in normal tissues. A pertinent analysis of

  2. Porous platinum nanoparticles and PdPt nanocages for use in an ultrasensitive immunoelectrode for the simultaneous determination of the tumor markers CEA and AFP

    International Nuclear Information System (INIS)

    Liu, Na; Feng, Feng; Liu, Zhimin; Ma, Zhanfang

    2015-01-01

    We describe the use of porous platinum nanoparticles (pPt NPs) and PdPt nanocages (PdPt NCs) in an electrochemical immunoassay for two tumor markers (CEA and AFP) directly in serum and with enhanced detection performance. The pPt NPs possess a high specific surface area and electrical conductivity, while the PdPt NCs display excellent catalytic property and high loading capacity. The PdPt NCs were labeled with anti-CEA and thionine, and the PdPt NCs were labeled with anti-AFP and ferrocene. The resulting electrode displayed a large decrease of the anodic peak current and an increase of cathodic peak current for hydrogen peroxide (H 2 O 2 ). The dual square wave voltammetric immunoassay was performed at −0.1 V (for CEA) and +0.6 V (for AFP) after exposure to a sample containing CEA and AFP and in the presence of H 2 O 2 . CEA can be detected in the 0.05 to 200 ng mL −1 concentration range and AFP between 0.03 and 100 ng mL −1 . The limits of detection are 1.4 pg mL −1 for CEA and 1 pg mL −1 for AFP (at an SNR of 3). The sensitivity of the method (expressed as slope vs. concentration) is better by a factor of 4.6 to 100 compared to conventional electrochemical immunoassays. Analytical data obtained with diluted serum samples were in good agreement with reference values obtained via a standard ELISA. Negligible cross-reactivity is found between CEA and AFP. In our opinion, this approach paves the way for developing other kinds of electrochemical immunosensors based on the use of pPt NPs and PdPt NCs as materials for designing new electrode interfaces. (author)

  3. Le CRDI en Colombie

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le CRDI appuie la recherche en Colombie dans des domaines tels ... Le CRDI a soutenu des activités de longue haleine qui ont eu pour ... Des travaux subventionnés par le CRDI ont aidé une fondation à intégrer Internet à son programme ...

  4. La construction de la matière le modèle Standard

    CERN Document Server

    Léon, Jacques

    2016-01-01

    Qu'est-ce que la matière ? Voilà une question à laquelle il pourrait sembler facile de répondre car il n'est rien de plus concret que la matière. Et pourtant, la réponse qu'en donne la physique contemporaine est pour le moins déconcertante ! Le concept-même de particules, briques élémentaires de la matière, s'est volatilisé, dissout dans des objets mathématiques abstraits et abscons pour les non-initiés. Plus nos théories sont précises et plus l'image qu'elles nous renvoient est insaisissable. En un siècle, la représentation des particules s'est métamorphosée en nuages de probabilité portés par des champs quantiques régis par des symétries confinées dans des espaces abstraits. Mais dans un même temps, nous avons réussi le tour de force d'expliquer toute cette complexité avec seulement 16 particules… et une seule théorie, véritable construction de notre conception de la matière : le modèle standard. Ce livre tente de guider le lecteur dans le dédale de la physique des particu...

  5. The CEA and alternative energies. 8 April 2010 press conference

    International Nuclear Information System (INIS)

    2010-01-01

    This document presents the CEA's strategy in terms of alternative energies and the various implemented research programs which mainly concern the building sector and the transport sector. After a recall of the energy and climate context, a presentation of the NTE program (Nouvelles Technologies de l'Energie, new energy technologies), the different topics and projects are presented: photovoltaic solar energy and its integration in building; batteries, hydrogen and fuel cells for applications in transports; second-generation bio-fuels

  6. Fulltext PDF

    Indian Academy of Sciences (India)

    Bellissard Jean, Georgia Inst. of Technology, Atlanta, USA. Bernard Guilhem, LAPTh, Annecy-le-Vieux, France. Blanchard Philippe, Univ. Bielefeld, Germany. Boudjema Fawzi, LAPTh, Annecy-le-Vieux, France. Brezin Edouard, LPT, Ecole Normale Supérieure, Paris, France. Bros Jacques, DSM/IPhT, CEA Saclay, France.

  7. Report of the CEA visiting committee on R and D for future nuclear energy systems, May 11-13, 2005

    International Nuclear Information System (INIS)

    Brechet, Y.; Ebbesen, T.; Fujiie, Y.; Richter, B.; Stormer, H.; Zinkle, S.J.

    2005-01-01

    This was the fifth meeting of the Visiting Committee of the CEA since its creation in year 2000. The first meeting gave members of the committee a broad overview of the entire spectrum of CEA research and subsequent meetings have focused on specific topics. These included the nuclear fuel cycle, biology, and micro and nano technologies. This meeting focused on research and development for future nuclear energy systems. The main division of CEA concerned with this topic is the Nuclear Energy Division. Some of the laboratories of the Technological Research and Matter Science Divisions are also involved in areas such as materials and basic nuclear data. The report deals with the fuels and waste, the SFR (Sodium Fast Reactor) and GFR (Gas Fast Reactor) programs, the Very High temperature reactor (VHTR), the actinide separation, the materials, the irradiation tests facilities and the personnel for the future. (A.L.B.)

  8. Report of the CEA visiting committee on R and D for future nuclear energy systems, May 11-13, 2005

    Energy Technology Data Exchange (ETDEWEB)

    Brechet, Y. [Institut National Polytechnique, ENSEEG/LTPCM, 38 - Grenoble (France); Ebbesen, T. [Universite Louis Pasteur, ISIS, 67 - Strasbourg (France); Fujiie, Y. [Nuclear Salon Fuj-ie (Japan); Richter, B. [Director Emeritus, Stanford Linear Accelerator Center (United States); Stormer, H. [Columbia Univ., Dept. of Physics (United States); Zinkle, S.J. [Oac Ridge National Laboratory, Metals and Ceramics Div. (United States)

    2005-07-01

    This was the fifth meeting of the Visiting Committee of the CEA since its creation in year 2000. The first meeting gave members of the committee a broad overview of the entire spectrum of CEA research and subsequent meetings have focused on specific topics. These included the nuclear fuel cycle, biology, and micro and nano technologies. This meeting focused on research and development for future nuclear energy systems. The main division of CEA concerned with this topic is the Nuclear Energy Division. Some of the laboratories of the Technological Research and Matter Science Divisions are also involved in areas such as materials and basic nuclear data. The report deals with the fuels and waste, the SFR (Sodium Fast Reactor) and GFR (Gas Fast Reactor) programs, the Very High temperature reactor (VHTR), the actinide separation, the materials, the irradiation tests facilities and the personnel for the future. (A.L.B.)

  9. Marantáceas Nuevas de Colombia

    Directory of Open Access Journals (Sweden)

    Smith Lyman B.

    1948-06-01

    Full Text Available Identificando numeroso material botánico en el United States National Herbarium, hemos hallado varias especies de la familia Marantaceae, especialmente de Colombia, que todavía no han sido descritas. No intentamos tratar sobre todas ellas en el presente trabajo, sino que nos limitamos a describir las más notables, dejando las demás para un estudio posterior, cuando se disponga de material más completo. Para poder entender con exactitud la estructura de las brácteas menores, así como de los pétalos y el androceo de estas plantas, no obstante lo mucho que se puede averiguar con ejemplares secos de herbario, es necesario que las observaciones se hagan sobre material vivo. La necesidad de estudiar en vivo las Marantáceas es mayor que En la gran mayoría de las familias que componen las Fanerógamas.

  10. Plasma TIMP-1 and CEA as markers for detection of primary colorectal cancer

    DEFF Research Database (Denmark)

    Christensen, Ib Jarle; Brünner, Nils; Dowell, Barry

    2015-01-01

    endoscopy were prospectively included (N=1965). Baseline data and co-morbidity were recorded. The primary end-point was the detection of CRC. Plasma was obtained before endoscopy and TIMP-1 and CEA levels were determined using an automated analysis platform when all samples were collected. RESULTS: CRC...

  11. Evaluation of recurrent disease in the re-staging of colorectal cancer by 18F-FDG PET/CT: Use of CEA and CA 19-9 in patient selection.

    Science.gov (United States)

    Chiaravalloti, Agostino; Fiorentini, Alessandro; Palombo, Erika; Rinino, Davide; Lacanfora, Annamaria; Danieli, Roberta; Di Russo, Carmen; Di Biagio, Daniele; Squillaci, Ettore; Schillaci, Orazio

    2016-11-01

    The aim of the present retrospective study was to evaluate the sensitivity and specificity of fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in assessing the recurrence of colorectal cancer (CRC) with regard to carcinoembryonic antigen (CEA) and carbohydrate antigen 19-9 (CA 19-9). 18 F-FDG PET/CT was performed in 100 patients for the re-staging of CRC. Therapy was discontinued prior to the examination. The mean (± standard deviation) CEA value (measured ~30 days prior to PET/CT examination) was 23.71 (±107) ng/ml, whereas the CA 19-9 value was 72 (±190.3) U/ml. Differences in CEA and CA 19-9 values in patients with scans that were positive or negative for recurrence were analyzed by means of a receiver operating characteristic (ROC) curve. ROC curves were used for the calculation of the sensitivity and specificity of 18 F-FDG PET/CT for the CEA and CA 19-9 levels. The results of the 18 F-FDG PET/CT were found to be associated with the CEA level (P=0.001), but not with the CA 19-9 level (P=0.43). PET/CT was positive for recurrence in 60 patients (60.0%), whose mean CEA and CA 19-9 values were 33.07±136.7 ng/ml and 75.24±192.3 U/ml, respectively. PET/CT was negative for recurrence in 40 patients (40.0%), whose mean CEA and CA 19-9 values were 10.15±30 ng/ml and 67.76±190 U/ml, respectively. On the basis of ROC curve analysis, the best compromise between sensitivity and specificity was achieved for CEA levels of 3.5 ng/ml [sensitivity, 80%; 95% confidence interval (CI), 67-89%; and specificity, 60%; 95% CI, 45-78%]. The study concluded that the detection of recurrence by 18 F-FDG PET/CT in patients treated for CRC is associated with CEA, but not CA 19-9 serum levels. Moreover, 18 F-FDG PET/CT should be recommended in patients with suspected CRC recurrence even when they present with CEA levels below the normal cut-off.

  12. Development and testing of the EDF-2 reactor fuel element; Essais et mise au point de l'element combustible pour le reacteur EDF-2

    Energy Technology Data Exchange (ETDEWEB)

    Delpeyroux, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Furhmann, R [Societe Industrielle de Combustible Nucleaire (France)

    1964-07-01

    rassemble les etudes qui ont ete necessaires pour mener a bien la definition de l'element combustible EdF 2. Apres un bref rappel des caracteristiques du reacteur EdF 2 et des options preliminaires ayant permis de fixer un avant-projet d'element combustible, on aborde les etudes proprement dites: - Etudes uranium: essais de passage d'une couronne interne du tube en phase {beta}, flechage du tube sous l'action d'une force concentree, soudage des pastilles d'extremites et verification de leur etancheite. La tenue du tube a l'ecrasement et la resistance des pastilles a l'enfoncement sous l'action de la pression externe sont etudiees en detail dans un autre rapport CEA - Etudes gaine: rappel des conditions de fabrication et verification de l'etancheite de la gaine, tenue des ailettes au fluage sous l'action du courant gazeux - Etudes d'extremites: fluage en compression et soudage des bouchons a la gaine. - Etudes cartouche: determination des caracteristiques des gorges d'ancrage gaine-combustible et des conditions de gainage, verification de la tenue au cyclage thermique de l'element combustible, determination de la chute de temperature au contact gaine-combustible traitee en detail dans un autre rapport CEA, - Etudes de l'ensemble: les etudes se rapportant a la chemise de graphite, au support et aux vibrations de la cartouche ont ete traitees par le service des Etudes Mecaniques et Thermiques (Section de Mecanique), Dans ce domaine, la Section d'Etude d'Elements Combustibles a etudie la tenue des centreurs sous l'action du courant gazeux. L'aboutissement des etudes est constitue par le dessin de l'element combustible, le schema de fabrication et les normes de fabrication. La validite de l'ensemble de ces essais hors pile sera confirmee par des assais en pile qui sont en cours et par l'irradiation des elements dans le reacteur EdF 2 lui-meme. En conclusion, on donne l'orientation des etudes pour l'amelioration de l'element combustible et la definition d'un element combustible

  13. Intelligence artificielle et agents collectifs : le modèle EUROSIM

    Directory of Open Access Journals (Sweden)

    Denise Pumain

    2007-07-01

    Full Text Available EUROSIM est un modèle multi-agents conçu pour simuler l’évolution à moyen terme du système des villes européennes. Les agents sont des entités collectives, les grandes villes caractérisées par leur taille et leur fonction dans le système des villes, et dont les interactions (échanges modulés par des relations de proximité ou de réseau déterminent la dynamique relative, tandis que la croissance d’ensemble dépend de l’innovation. Des outils d’analyse multiscalaire ont été développés afin d’interpréter les sorties du modèle et faciliter le calibrage.

  14. ÉTUDE DE CAS — Cuba : Le logement et le capital humain à Cuba ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    10 janv. 2011 ... ÉTUDE DE CAS — Cuba : Le logement et le capital humain à Cuba ... Centre de recherches pour le développement international (CRDI) du Canada révèle ... Les ressources déjà limitées sont devenues encore plus rares. ... de l'Institut national pour l'hygiène, l'épidémiologie et la microbiologie (INHEM), ...

  15. Lele du langage de programmation dans la réalisation de code ...

    African Journals Online (AJOL)

    Lele du langage de programmation dans la réalisation de code de qualité, les cas de Delphi et C++ Nous discutons dans ce papier lele du langage de programmation dans la production d'un code de qualité. La qualité d'un code peut être atteinte en respectant certains critères simples au niveau de la programmation ...

  16. Gossip Girls : lele du potin dans quelques romans pour adolescentes

    Directory of Open Access Journals (Sweden)

    Daniela Di Cecco

    2014-04-01

    Full Text Available Cet article explore lele joué par le potin dans une sélection de romans anglophones publiés aux Etats-Unis et au Canada pour adolescentes et préadolescentes. Des études psychologiques et sociologiques récentes sur les agressions féminines et la façon dont les filles infligent de la peine aux autres filles de façon indirecte et voilée servent de cadre à notre analyse. Le fait que la violence physique soit considérée comme un comportement réservé aux garçons et donc inapproprié pour les filles, incite les adolescentes à agir autrement. Le potin devient parfois une arme pour marginaliser ou punir une fille, mais il peut aussi jouer un rôle positif au niveau de la cohésion d’une bande et de la solidarité entre filles.

  17. Lithium/polymer batteries. Safety approach of the BT-EDF-CEA project; Accumulateurs lithium/polymere. Demarche securite du projet BT-EDF-CEA

    Energy Technology Data Exchange (ETDEWEB)

    Lascaud, S.; Baudry, P. [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Majastre, H. [Bollore Technologies, 29 - Quimper (France); Bloch, D. [CEAGrenoble, CEREM, 38 (France)

    1996-12-31

    The BT-EdF-CEA consortium for the development and the performance improvement of lithium/polymer batteries has carried out a safety analysis of the industrial risk and the risk for users linked with this new technology. The process chosen for the manufacturing of lithium/polymer batteries does not generate any particular risk of personnel or environmental contamination. Security tests have permitted to observe and analyze the behaviour of 4 Ah elements during thermal shocks, perforation and crushing, and during external short-circuit on 20 Ah elements. These tests demonstrate the great thermal stability and the excellent behaviour of batteries in the case of partial destruction. (J.S.) 2 refs.

  18. Lithium/polymer batteries. Safety approach of the BT-EDF-CEA project; Accumulateurs lithium/polymere. Demarche securite du projet BT-EDF-CEA

    Energy Technology Data Exchange (ETDEWEB)

    Lascaud, S; Baudry, P [Electricite de France, 77 - Moret sur Loing (France). Direction des Etudes et Recherches; Majastre, H [Bollore Technologies, 29 - Quimper (France); Bloch, D [CEAGrenoble, CEREM, 38 (France)

    1997-12-31

    The BT-EdF-CEA consortium for the development and the performance improvement of lithium/polymer batteries has carried out a safety analysis of the industrial risk and the risk for users linked with this new technology. The process chosen for the manufacturing of lithium/polymer batteries does not generate any particular risk of personnel or environmental contamination. Security tests have permitted to observe and analyze the behaviour of 4 Ah elements during thermal shocks, perforation and crushing, and during external short-circuit on 20 Ah elements. These tests demonstrate the great thermal stability and the excellent behaviour of batteries in the case of partial destruction. (J.S.) 2 refs.

  19. 205 Le Role de la Litterature dans le Developpement de la Nation ...

    African Journals Online (AJOL)

    Ike Odimegwu

    du plaisir en même temps qu'il le moralise. Elle fait naître dans ses lecteurs ou dans son audience des .... développement de l'esprit>>(319)Par cette définition nous comprenons que le développement signale qu'il du progrès ... qu'elle est une œuvre de l'imagination qui aide l'homme à transcender le monde physique.

  20. Rapport financier trimestriel pour le trimestre qui a pris fin le 30 juin ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Sophie Comeau

    30 juin 2017 ... Régi par la Loi sur le Centre de recherches pour le développement international ... des retombées; forme des leaders dans les secteurs de l'administration .... Au cours de la période de trois mois qui a pris fin le 30 juin 2017, ...

  1. Le jeu de la création : Le mangeur (2005 de Ying Chen

    Directory of Open Access Journals (Sweden)

    Nicole Dunham

    2013-11-01

    Full Text Available Le théoricien James Hans définit le jeu comme une déconstruction structurante, un processus de perpétuelle remise en question. Dans Le Mangeur (2005 de Ying Chen, la narratrice revit un épisode d’une de ses vies passées où elle meurt mangée, avalée, par son père, descendant dans le « tunnel » du ventre de ce dernier. Cependant, suite à cet événement, elle se retrouve dans un autre espace-temps où elle rencontre son mari, A.. Une équivalence s’établit dans le roman entre les éléments suivants : le ventre du père, les tableaux peints par ce dernier et l’espace-temps de A., et la fenêtre. Ces éléments deviennent des aires de jeu, remettant en question les concepts de l’intérieur et de l’extérieur et du créateur et de l’œuvre. En nous servant du texte « Le Tunnel » écrit par Ying Chen, nous démontrerons que cette notion du jeu s’applique également à l’ensemble de son œuvre.

  2. BioTfueL Project: Targeting the Development of Second-Generation Biodiesel and Biojet Fuels Le projet BioTfueL : un projet de développement de biogazole et biokérosène de 2 génération

    Directory of Open Access Journals (Sweden)

    Viguié J.-C.

    2013-10-01

    Full Text Available 2nd generation biofuels will have an important part to take in the energy transition as far as fuels are concerned. Using non edible biomass, they will avoid any direct competition with food usage. Within 2nd generation biofuels, the BTL route consists in the production of middle distillates (Diesel and jet fuel via gasification and Fischer-Tropsch (FT synthesis. These fuels are called “drop in” fuels; this means that to be used they technically do not request any modification in the vehicle whatever the blending rate with conventional fuels. This route is currently at the pre-industrial phase where demonstration is required. This article presents the BioTfueL project which has been created by Axens, CEA, IFP Energies nouvelles, Sofiprotéol, ThyssenKrupp Uhde and Total. This project is focused on the original concept of co-processing (biomass can be gasified together with fossil feedstock and proposes to develop and demonstrate a full process chain to be commercialized worldwide via licensing. Les biocarburants de 2e génération ont un rôle important à jouer en ce qui concerne le pool carburant dans le cadre de la transition énergétique. Utilisant comme matière première de la biomasse non comestible, ces carburants éviteront toute compétition directe avec un usage alimentaire de cette ressource. Parmi les biocarburants de 2e génération, la voie BTL consiste en la production de distillats moyens (gazole moteur et carburéacteur via gazéification et synthèse Fischer-Tropsch (FT. Ces carburants sont communément appelés des « drop in fuels », ce qui signifie que techniquement ils ne nécessitent aucune modification du véhicule quelque soit leur taux d’incorporation dans les carburants traditionnels. Cette voie entre actuellement en phase préindustrielle pour laquelle une démonstration est nécessaire. Cet article présente le projet BioTfueL qui est porté par Axens, le CEA, IFP Energies nouvelles, Sofiprotéol, Thyssen

  3. Le facteur humain et la sûreté de fonctionnement dans le ...

    African Journals Online (AJOL)

    Elle permettait d'optimiser le couple « performance-coût », en identifiant, évaluant et maîtrisant les pannes qu'il ... gestion des risques deviennent une ...... Etre en mesure de détecter les .... variés qui s'y déroulent, avoir le contrôle du.

  4. Evaluation of tumor markers (HER-2/neu oncoprotein, CEA, and CA 15.3) in patients with locoregional breast cancer: prognostic value.

    Science.gov (United States)

    Molina, Rafael; Augé, Jose M; Escudero, Jose M; Filella, Xavier; Zanon, Gabriel; Pahisa, Jaume; Farrus, Blanca; Muñoz, Montserrat; Velasco, Martin

    2010-06-01

    Tumor markers were studied in the sera of 883 untreated patients with primary breast cancer diagnosed between 1989 and 2007. Abnormal human epidermal growth factor receptor 2 (HER-2)/neu levels (>15 ng/mL) were found in 9.5%, carcinoembryonic antigen (CEA) in 15.9%, and cancer antigen (CA) 15.3 in 19.7% of the patients. One or more tumor markers were abnormal in 305 (34.5%) of the 883 studied patients. Significantly higher serum HER-2/neu levels were found in patients with tissue overexpression of this oncoprotein (p CEA, CA 15.3, and HER-2/neu (only in those patients with tissue overexpression) serum levels were related with tumor stage (tumor size and nodal involvement) and steroid receptors (higher values in estrogen receptor-negative (ER-) tumors). Univariate analysis showed that HER-2/neu serum levels were prognostic factors in disease-free survival (DFS) and overall survival (OS) only in patients with tissue overexpression. Multivariate analysis in 834 patients show that nodal involvement, tumor size, ER, CEA, and adjuvant treatment were independent prognostic factors in DFS and OS. When only patients with HER-2/neu overexpression in tissue were studied, tumor size, nodal involvement, and tumor markers (one or another positive) were independent prognostic factors for both DFS and OS. HER-2/neu serum levels were also an independent prognostic factor, with CEA, ER, and nodes in 106 patients treated with neoadjuvant treatment. In summary, serum HER-2/neu, CEA, and CA 15.3 are useful tools in the prognostic evaluation of patients with primary breast cancer.

  5. Diagnostic value of combined determination of serum AFP, CEA, CA199, SF levels in patients with primary hepatic carcinoma

    International Nuclear Information System (INIS)

    Wu Jiaming; Rui Zhilian

    2005-01-01

    Objective: To investigate the diagnostic value of combined detection of four tumor markers in patients with possible malignant change in liver disorders. Methods: Serum AFP, CEA, CA199 and SF levels were determined with chemiluminescence immunoassay (CLIA) in 49 patients with primary liver carcinoma, 7 patients with metastatic liver carcinoma, 40 patients with hepatic cirrhosis, 47 patients with HBV hepatitis and 30 controls. Results: The serum levels of AFP, CEA, SF in patients with primary hepatic cancer and serum levels of AFP, SF in patients with hepatic cirrhosis were all significantly higher than those in controls (P 0.05). Moreover, positive rate of combined determination of AFP, CEA, CA199, SF in patients with primary hepatic cancer was significantly higher than that in patients with metastatic liver cancer. Conclusion: With combined determination of these four tumor markers, the detection rate of primary hepatic carcinoma could be enhanced to above 95%. Also, differential diagnosis between primary and metastatic hepatic cancers could be facilitated. (authors)

  6. Lele de l’audit interne dans le pilotage et la performance du système de contrôle interne : cas d’un échantillon d’entreprises algériennes

    OpenAIRE

    Chekroun, Meriem

    2013-01-01

    Les scandales financiers qui ont ébranlé récemment les entreprises publiques algériennes, telle que l’entreprise Sonatrach, ont mis sur le devant de la scène la nécessité de renforcer le système de contrôle interne (SCI) qui est considéré de plus en plus comme une solution à un large éventail de problèmes latents ( les problèmes d’ordre éthique,…), y compris la fonction d’audit interne ayant un rôle prépondérant dans le pilotage et la performance du SCI. Pour ce faire, l’audit ...

  7. A Case of Radiation Fibrosis Appearing as Mass-Like Consolidation after SBRT with Elevation of Serum CEA

    Directory of Open Access Journals (Sweden)

    Kotaro Terashima

    2010-01-01

    Full Text Available We report a case of radiation fibrosis appearing as mass-like consolidation, which was difficult to distinguish from local recurrence. A 72-year-old woman was diagnosed as having primary lung cancer (cT1N0M0 stage IA in the right upper lobe and was treated with SBRT of 48 Gy in 4 fractions. After 12 months, mass-like consolidation appeared around the irradiated area, and after 13 months, it had increased in size. FDG-PET revealed high uptake (SUV max=5.61 for the consolidation. CT-guided biopsy was performed, but we could not confirm the diagnosis. Considering her poor respiratory function and her age, short-interval follow-up was performed. After 15 months, the consolidation enlarged at the dorsal side, and carcinoembryonic antigen (CEA became elevated (14.6 ng/mL. Serum KL-6 (436 U/mL and SP-D (204 ng/mL were also elevated. However, after 16 months, serum CEA slightly decreased. The consolidation gradually retracted on follow-up CT images. CEA, KL-6, and SP-D were also decreased by degrees. After 40 months, there is no evidence of local recurrence.

  8. Lele des institutions dans le processus de l’innovation ; l’apport de Thorstein Veblen

    Directory of Open Access Journals (Sweden)

    Diane-Gabrielle Tremblay

    2007-10-01

    Full Text Available Nous nous intéressons ici au rôle des institutions dans le processus de l’innovation, puisque Veblen le met en valeur. Cet apport de Veblen nous paraît déterminant pour mieux comprendre l’innovation, surtout que l’on parle de plus en plus d’une diversité de formes d’innovation (technologique, mais aussi organisationnelle, sociale et de produit, et que celles-ci sont mieux comprises lorsque l’on tient compte du rôle des institutions dans la diffusion ou le blocage de l’innovation. Veblen met aussi en évidence le caractère parfois retardataire des institutions, ainsi que la réciprocité des effets entre technologie et institutions, autant d’éléments fort pertinents pour l’analyse, encore aujourd’hui.This paper addresses the role of institutions in the process of innovation, since Veblen highlights this role. This contribution of Veblen appears determinant to better understand the process of innovation, especially in a context where we are more and more interested in various forms of innovation (technological, but also organisational, social and product innovations; these various forms of innovation are better understood and analysed when the role of institutions in their diffusion or lack of diffusion is taken into account. Veblen also highlights the fact that institutions sometimes block or slow down the process of diffusion of innovations, as well as the reciprocity of effects between technology and institutions, contributions which are all the more important for the analysis of innovation today.

  9. le 3 : Quels impacts sur le financement des pays émergents ?

    OpenAIRE

    Figuet, Jean-Marc; Humblot, Thomas; Lahet, Delphine

    2013-01-01

    La persistance de crises bancaires démontre l'incapacité des établissements de crédit à s'autoréguler. De ce fait, le Comité de Bâle étend largement le périmètre de la nouvelle règlementation prudentielle. Sur la base de la littérature sur les déterminants des flux de capitaux transfrontières et d'un GMM système, cet article analyse l'impact potentiel de l'accord Bâle 3 sur les flux de capitaux bancaires provenant des banques de 16 pays industrialisés à destination d'un panel de 30 pays émerg...

  10. Le glaive et la chair : le pouvoir et son incarnation au temps des derniers Valois

    OpenAIRE

    Roux, Nicolas Le

    2014-01-01

    Au xvie siècle, pouvait-on concevoir la monarchie autrement qu’incarnée ? Servir le roi, c’était servir un prince auquel on était lié personnellement, et non une institution abstraite. Le monarque devait apparaître comme un compagnon pour la noblesse militaire. Henri II représentait le modèle du roi chevalier. Contrairement à son père, Charles IX ne faisait pas la guerre, mais il épuisait son corps dans d’interminables chasses. Henri III a tenu dans sa jeunesse lele de chef de guerre. Deve...

  11. Evaluation of recurrent disease in the re-staging of colorectal cancer by 18F-FDG PET/CT: Use of CEA and CA 19–9 in patient selection

    Science.gov (United States)

    Chiaravalloti, Agostino; Fiorentini, Alessandro; Palombo, Erika; Rinino, Davide; Lacanfora, Annamaria; Danieli, Roberta; Di Russo, Carmen; Di Biagio, Daniele; Squillaci, Ettore; Schillaci, Orazio

    2016-01-01

    The aim of the present retrospective study was to evaluate the sensitivity and specificity of fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in assessing the recurrence of colorectal cancer (CRC) with regard to carcinoembryonic antigen (CEA) and carbohydrate antigen 19–9 (CA 19–9). 18F-FDG PET/CT was performed in 100 patients for the re-staging of CRC. Therapy was discontinued prior to the examination. The mean (± standard deviation) CEA value (measured ~30 days prior to PET/CT examination) was 23.71 (±107) ng/ml, whereas the CA 19–9 value was 72 (±190.3) U/ml. Differences in CEA and CA 19–9 values in patients with scans that were positive or negative for recurrence were analyzed by means of a receiver operating characteristic (ROC) curve. ROC curves were used for the calculation of the sensitivity and specificity of 18F-FDG PET/CT for the CEA and CA 19–9 levels. The results of the 18F-FDG PET/CT were found to be associated with the CEA level (P=0.001), but not with the CA 19–9 level (P=0.43). PET/CT was positive for recurrence in 60 patients (60.0%), whose mean CEA and CA 19–9 values were 33.07±136.7 ng/ml and 75.24±192.3 U/ml, respectively. PET/CT was negative for recurrence in 40 patients (40.0%), whose mean CEA and CA 19–9 values were 10.15±30 ng/ml and 67.76±190 U/ml, respectively. On the basis of ROC curve analysis, the best compromise between sensitivity and specificity was achieved for CEA levels of 3.5 ng/ml [sensitivity, 80%; 95% confidence interval (CI), 67–89%; and specificity, 60%; 95% CI, 45–78%]. The study concluded that the detection of recurrence by 18F-FDG PET/CT in patients treated for CRC is associated with CEA, but not CA 19–9 serum levels. Moreover, 18F-FDG PET/CT should be recommended in patients with suspected CRC recurrence even when they present with CEA levels below the normal cut-off. PMID:27895793

  12. Microflora de Bromeliáceas do estado de Pernambuco, Brasil

    Directory of Open Access Journals (Sweden)

    Luis Tavares de Lyra

    1976-01-01

    Full Text Available O autor estudou a microflora de dois gêneros de BROMELIACEAE: Hoenbergia e Portea. As coletas do material foram feitas em seis regiões do Estado de Pernambuco; 1 Região da Mata-Úmida; 2 Região da Mata-Seca; 3 Região do Agreste Central; 4 Região do Agreste Setentrional; 5 Região do Agreste Meridional; 6 Região do Recife. As seguintes diatomáceas indicadoras de águas poluídas (espécies oligossaprobias foram encontradas nas seis regiões estudadas: Gomphonema parvulum (Kutz Grunow., Hantzschia amphioxys Grunow, Pinnularia borealis Ehr., Pinnularia microstauron (Ehr Cleve, gomphonema gracile Ehr., Nitzschia palea Kutz., Melosira roeseana Rabenh., Navicula mutica Kutz., Navicula cryptocephala Kutz., Eunotia pectinalis (Kutz Rabenh. Foram também observadas CHLOROPHYCEAS nas estações chuvosa e seca nas diversas regiões. Algumas são indicadoras de oligossaprobidade: Scenedesmus quadricauda (Turpin brebisson. Chlorococcum sp., Chlorella sp. Os fatores ecológicos e comentários referentes ás diatomáceas foram anotados no texto. A tabela I indica a frequência das diatomáceas nas seis regiões estudadas. Maior número dessas diatomáceas, registramos nas regiões do Agreste. A tabela II mostra a temperatura e pH da água de Hoenbergia e Portea em ambas as estações do ano (inverno e verão. Observamos a ocorrência de larvas de culex em Portea e hoenbergia, entretanto, raramente encontramos larvas de Anopheles. As coletas foram feitas durante as estações chuvosa e seca em Hoenbergia e Portea. Determinamos 35 espécies provenientes de 78 amostras coletadas durante o período de 26 meses.The author studied the microflora from two genera of Bromeliaceae: Hoenbergia and Portea. The material was collected in six natural regions of Pernambuco State: 1 Humid Forest Region; 2 Dry forest region; 3 Central Agreste Region; 4 Setentrional Agreste Region; 5 Meridional Agreste Region; 6 Recife Region. The following diatoms that indicate polluted

  13. Diagnostic efficacy of CA 15-3 and CEA in the early detection of metastatic breast cancer-A retrospective analysis of kinetics on 743 breast cancer patients.

    Science.gov (United States)

    Stieber, Petra; Nagel, Dorothea; Blankenburg, Irene; Heinemann, Volker; Untch, Michael; Bauerfeind, Ingo; Di Gioia, Dorit

    2015-08-25

    We investigated the diagnostic capacity of CEA and CA 15-3 kinetics for the early detection of metastatic disease in comparison to fixed cut off values. In a retrospective analysis, a total of 743 patients with early breast cancer and available baseline values of CEA and CA 15-3 were included. A reproducible increase of 100% of single or combined markers was considered as a strong indicator of metastatic disease. 187 patients developed metastatic disease and 556 remained disease-free. On the basis of tumor marker kinetics, we reached a specificity of >98% for both biomarkers and a sensitivity of 40.6% for CEA alone, 55.6% for CA 15-3 alone and 66.3% for the combination of both markers. Using fixed cut-off values (CEA: 4ng/mL, CA 15-3: 30U/mL) we ended up with a specificity of 86.3% and a sensitivity of 70.6% for the combination of CEA and CA 15-3. Using higher cut-off values (CEA: 6ng/mL, CA 15-3: 60U/mL) we reached a specificity of 96.9% and a sensitivity of 49.7% for the combination. We conclude that the interpretation of these markers in follow-up using individual baseline values and kinetics leads to a significant superior profile of specificity and sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Le don gratuit. Le cas d'un établissement public

    OpenAIRE

    Barel , Yvan; Frémeaux , Sandrine

    2008-01-01

    Disponible en ligne : http://www.annales.org/gc/2008/gc94/barel.pdf; La logique de la réciprocité est le cadre d'analyse dominant de la relation de travail. La logique du don/contredon s'inscrit dans ce même cadre de référence, en postulant qu'aucune relation d'échange ne peut survivre à une situation d'asymétrie trop forte (MAUSS, 1924). Mais elle ajoute une idée nouvelle en mettant en exergue le " tabou du calcul " (BOURDIEU, 1980) : le désir de contredon n'est pas toujours manifesté, ni mê...

  15. Interpretation of experiments made in ZEBRA CADENZA assemblies with CEA formulary

    International Nuclear Information System (INIS)

    D'Angelo, A.; Rimpault, G.

    1983-06-01

    A benchmark exercise on fast critical heterogeneity method assessment has been proposed in the framework of NEACRP. It is based on the analysis of two integral experiments performed by UKAEA on the ZEBRA facility (the CADENZA assemblies): - a plate fuelled core (ZEBRA 22); - a 75% pin fuelled core (ZEBRA 23). The interpretation of these experiments has been done using the current standard CEA methods. We find a relevant (650 pcm) discrepancy between the ''k'' values of ZEBRA 22 and ZEBRA 23 pin assemblies. We try in this report to find out the origin of this discrepancy. The spatial k-value calculation results and corrections are affected by nomore than 150 pcm and are partially correlated. Moreover, this discrepancy does not seem to be explained in terms of homogenous infinite dilute cross section effects. It has been found that most of the discrepancy can be traced back to heterogeneity effects, and mainly to the heterogeneity effects of the metallic fuel plate in the metallic fuel plate in the ZEBRA 22 cell. Finally, the pin core gives, in the CEA analysis, a Keff E-C value well inside the known performance of the adjusted CARNAVAL IV formulaire (i.e. E-C =+ 300 + +500+-200 pcm) for plutonium fuelled cores

  16. Sertula Florae Colombiae – XV: Nuevas Melastomatáceas

    Directory of Open Access Journals (Sweden)

    Uribe Uribe Lorenzo

    1980-09-01

    Full Text Available El notable aumento de las colecciones del Herbario Nacional Colombiano muestran la riqueza de la flora melastomatácea de Colombia. Uno de los géneros más ricos y más bien caracterizados es Blakea. En este artículo describo dos nuevas especies muy interesantes. Dejo consignada mi gratitud para elnotable dibujante, don Silvio Fernández Valencia, a quien se deben las magníficas ilustraciones y muchos datos y mediciones de órganos pequeñísimos, que facilitaron  las descripciones exactas de las plantas.

  17. Le salaire minimum n'est pas toujours le meilleur moyen d'accroître ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    4 mai 2016 ... De fait, cette intervention vigoureuse sur le marché du travail est une ... la mobilité des travailleurs entre le secteur structuré et le secteur non structuré, ... On peut certes se constituer rapidement du capital politique en faisant ...

  18. Bibliographie sélective sur le corps

    Directory of Open Access Journals (Sweden)

    Anne-Claire Rebreyend

    2007-11-01

    Full Text Available Ouvrages générauxBruit Zaidman Louise, Houbre Gabrielle, Klapisch-Zuber Christiane, Schmitt Pantel Pauline (dir., Le corps des jeunes filles de l'Antiquité à nos jours, Paris, Perrin, 2001.Vigarello Georges, Le propre et le sale. L'hygiène du corps depuis le Moyen Âge, Paris, Seuil, 1985.—, Le sain et le malsain : santé et mieux-être depuis le Moyen Âge, Paris, Seuil, 1993.—, Histoire de la beauté. Le corps et l'art d'embellir de la Renaissance à nos jours, Paris, Seuil, 2004.Le corps au Moy...

  19. Digitization and valorization through the INIS database of an exceptional stock of grey literature documents: the 'historical' CEA reports (1948-1969); Numerisation et valorisation au travers de la base INIS d'un fonds documentaires exceptionnel de litterature grise: les rapports 'historiques' du CEA (1948-1969)

    Energy Technology Data Exchange (ETDEWEB)

    Surmont, J.; Brulet, C.; Brulet, M.; Pourny, M.; Constant, A.; Guille, N.; Le Blanc, A.; Mouffron, O.; Anguise, P.; Jouve, J.J

    2008-07-01

    This poster, prepared for the sixth edition of the meetings of scientific and technical information professionals (RPIST, Nancy (France)), presents the joint CEA/IAEA project of digitization of the collection of reports published by the French atomic energy commission (CEA) between 1948 and 1969. This exceptional stock of about 2760 grey literature monographs covers the first 20 years of researches carried out at the CEA and has been entered in the INIS database with a link to the full text. The poster describes the different steps of the project from the selection of the documents, their digitization, and the preparation of the corresponding inputs. The INIS database and its general content are briefly presented. (J.S.)

  20. Perfil cualitativo de metabolitos secundarios en la fracción comestible de especies leñosas seleccionadas por vacunos en un bosque semicaducifolio

    Directory of Open Access Journals (Sweden)

    Á Ojeda

    Full Text Available Con el fin de caracterizar cualitativamente el perfil de metabolitos secundarios de la fracción comestible de plantas leñosas seleccionadas por vacunos en silvopastoreo, las cuales se encuentran en un bosque tropófilo semicaducifolio de Venezuela, se utilizaron 14 vacunos machos Brahman x Holstein de 390,4 ± 18,0 kg de PV. Estos fueron manejados en pastoreo continuo en una superficie de 81 ha, de las cuales 50 ha correspondían a un bosque semicaducifolio y el resto, a vegetación herbácea natural (Cynodon nlemfuensis, Sporobolus indicus, Axonopus sp., Mimosa pudica e Hyptis suaveolens. La composición de la biomasa leñosa seleccionada por los animales se estudió mediante la evaluación de los fragmentos epidérmicos presentes en las heces colectadas por vía transrectal, cada 15 días. A partir de estos resultados, se tomaron muestras de cinco plantas por especie leñosa, en los periodos seco y lluvioso. Se determinaron 15 grupos de metabolitos: alcaloides, á-aminos, carbohidratos solubles, cardenólidos, cianógenos, esteroles, fenoles totales, flavonoides, lectinas, mucílagos, quinonas, saponinas, taninos extractables (totales y condensados y terpenoides. La mayoría de la biomasa correspondió a especies de la familia Fabaceae, las cuales presentaron todos los metabolitos evaluados. En ambos periodos se detectaron niveles de esteroles, terpenoides, fenoles totales y taninos extractables que variaron desde leves hasta cuantiosos. Con independencia del periodo, el 66,7 % de las especies presentó entre 10-11 metabolitos secundarios en su biomasa comestible. Se recomienda realizar estudios para la cuantificación de los metabolitos secundarios presentes en plantas leñosas de valor forrajero, para este sistema silvopastoril

  1. Rapport financier trimestriel pour le trimestre qui a pris fin le 30 juin

    International Development Research Centre (IDRC) Digital Library (Canada)

    Office 2004 Test Drive User

    30 juin 2016 ... Le CRDI finance des travaux de recherche appliquée ... développement international (le Centre) et lʼévolution de la ..... voie de développement et sur la mise en oeuvre des connaissances scientifiques, techniques et autres en vue .... Les accords expirent à des dates différentes, et le dernier prend fin en.

  2. Report of transparency and nuclear safety 2007 CEA Fontenay aux Roses

    International Nuclear Information System (INIS)

    2007-01-01

    This report presents the activities of the CEA Center of Fontenay aux roses for the year 2007. After many years of decommissioning and dismantling of nuclear installations, the Center is now devoted (since 2005) to the development of research programmes on biology and biomedical technologies. The actions concerning the safety, the radiation protection, the significant events, the release control and the environmental impacts and the wastes stored on the center are discussed. (A.L.B.)

  3. Current regulator for the stabilization of an electrostatic Van de Graaff generator; Regulateur de courant pour stabilisation d'un generateur electrostatique Van de Graaff

    Energy Technology Data Exchange (ETDEWEB)

    Gabet, A; Taieb, J [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    In a previous report (CEA report number 46) we described a current regulator destined to enslave the current of charge of the strap of a model of Van de Graaff. We will now describe the regulator destined to the 5 MeV Van de Graaff built in the Nuclear center of Saclay. (author) [French] Dans un precedent rapport (rapport C.E.A. numero 46) nous avons decrit un regulateur de courant destine a asservir le courant de charge de la courroie d'une maquette de Van de Graaff. Nous decrirons maintenant le regulateur destine au Van de Graaff de 5 MeV construit au Centre d'Etudes Nucleaires de Saclay. (auteur)

  4. Répercussions de la floriculture sur l'environnement et la santé en ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Pendant la phase I du projet (no 100661), le Centro de Estudios y Asesoría en Salud (CEAS), sous la direction de Jaime Breilh, a entrepris de jouer un rôle très actif dans le domaine de l'écosanté et de la floriculture en Équateur en établissant des liens entre institutions à l'échelle tant nationale qu'internationale.

  5. Value of {sup 18}F-FDG uptake on PET/CT and CEA level to predict epidermal growth factor receptor mutations in pulmonary adenocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kai-Hsiung; Hsu, Hsian-He; Chang, Wei-Chou; Hsu, Yi-Chih; Chang, Tsun-Hou [Tri-Service General Hospital and National Defense Medical Center, Department of Radiology, Taipei 114 (China); Huang, Tsai-Wang; Chang, Hung [Tri-Service General Hospital and National Defense Medical Center, Department of Thoracic Surgery, Taipei (China); Gao, Hong-Wei [Tri-Service General Hospital and National Defense Medical Center, Department of Pathology, Taipei (China); Shen, Daniel H.Y. [Tri-Service General Hospital and National Defense Medical Center, Department of Nuclear medicine, Taipei (China); Chu, Chi-Ming [Institute of Public Health, National Defense Medical Center and University, Section of Health Informatics, Taipei (China); Ho, Ching-Liang [Tri-Service General Hospital and National Defense Medical Center, Division of Hematology-Oncology, Department of Internal Medicine, Taipei (China)

    2014-10-15

    The identification of the mutation status of the epidermal growth factor receptor (EGFR) is important for the optimization of treatment in patients with pulmonary adenocarcinoma. The acquisition of adequate tissues for EGFR mutational analysis is sometimes not feasible, especially in advanced-stage patients. The aim of this study was to predict EGFR mutation status in patients with pulmonary adenocarcinoma based on {sup 18}F-fluorodeoxyglucose (FDG) uptake and imaging features in positron emission tomography/computed tomography (PET/CT), as well as on the serum carcinoembryonic antigen (CEA) level. We retrospectively reviewed 132 pulmonary adenocarcinoma patients who underwent EGFR mutation testing, pretreatment FDG PET/CT and serum CEA analysis. The associations between EGFR mutations and patient characteristics, maximal standard uptake value (SUVmax) of primary tumors, serum CEA level and CT imaging features were analyzed. Receiver-operating characteristic (ROC) curve analysis was performed to quantify the predictive value of these factors. EGFR mutations were identified in 69 patients (52.2 %). Patients with SUVmax ≥6 (p = 0.002) and CEA level ≥5 (p = 0.013) were more likely to have EGFR mutations. The CT characteristics of larger tumors (≥3 cm) (p = 0.023) and tumors with a nonspiculated margin (p = 0.026) were also associated with EGFR mutations. Multivariate analysis showed that higher SUVmax and CEA level, never smoking and a nonspiculated tumor margin were the most significant predictors of EGFR mutation. The combined use of these four criteria yielded a higher area under the ROC curve (0.82), suggesting a good discrimination. The combined evaluation of FDG uptake, CEA level, smoking status and tumor margins may be helpful in predicting EGFR mutation status in patients with pulmonary adenocarcinoma, especially when the tumor sample is inadequate for genetic analysis or genetic testing is not available. Further large-scale prospective studies are

  6. Behaviour of heavy water in nuclear reactors of the CEA; Comportement de l'eau lourde dans les piles du C.E.A

    Energy Technology Data Exchange (ETDEWEB)

    Chenouard, J; Dirian, G; Roth, E [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1955-07-01

    In the two heavy water reactors of the CEA: Zoe and P-2, we do: A) the supervision of the isotopic composition of the heavy water; B) the supervision of gases released by the decomposition of the heavy water under radiation, and to their recombination; C) periodic analyses of impurities. (M.B.) [French] Dans les deux piles a eau lourde du Commissariat a l'Energie Atomique: Zoe et P 2, nous effectuons: A) la surveillance de la composition isotopique de l'eau lourde; B) la surveillance des gaz degages par la decomposition de l'eau lourde sous radiation, et a leur recombinaison; C) des analyses periodiques d'impuretes. (M.B.)

  7. Tumelo le Moruo

    Directory of Open Access Journals (Sweden)

    Vuyani S. Vellem

    2015-03-01

    Full Text Available Paleng ya rona batho ba batsho, tumelo ya boKreste e fihlile lefatsheng la rona la Afrika Borwa mmoho le dikgoka tsa ditjhaba tsa boPhirima. BoKreste bo fihlile ka nako ya dintwa tseo mohopolo wa tsona e neng e le ho hapa lefatshe la, batho ba batsho. Ka mantswe amang, rona batho ba batsho, re ile ra qetella re le setjhaba se ileng sa hlolwa, mme lefatshe la rona la nkuwa ka dikgoka. Ka hare ho dikgoka tsena, ho ne ho dutse tumelo ya boKreste. Makgowa a ile are: �A re kwaleng mahlo re rapeleng, rona ra kwala mahlo, mme ha re qeta hore Amen, re bula mahlo, ra fumana lefatshe le nkuwe matsohong a rona ho setse Bibele.� Re ile ra sala le Bibele eo ka yona re lekileng dilemong tse fitileng ho lwana ntwa ya topollo, kapa tokoloho hofihlela selemong sa 1994. Le ha re ile ra fumana tokoloho ka selemo seo, hare so ka re lokoloha ho tsa moruo. E kaba sena se bolela eng mabapi le tumelo ya rona ya boKreste? Segolweng sena re leka ho araba potso ena. Tumelo ke eng ho batho ba sa lokolohang moruong wa naha ya bona? Re lekola pale ya boKreste, tumelo ya batho le maemo a kereke ntlheng ya ho tadimana le tokoloho ka tumelo.Faith and economics. In our history from a black perspective, Christianity arrived through violent conquest from the west. Evidentially, this faith coincided with wars of dispossession and the ultimate defeat of black Africans. It is difficult to separate the violent defeat of black Africans from the arrival of Christian faith. This well-known statement within the circles of black Theology of liberation: When the white man arrived in our land he said, �let us pray and after prayer, when we opened our eyes, our land was taken and only the Bible was left in our hands,� captures the black sentiment of this history. Ironically, it was this Bible that black Africans used to wage their struggle for liberation up to the demise of apartheid in 1994.Nonetheless, political liberation is not enough as the struggle for economic liberation

  8. Serum tetranectin is an independent prognostic marker in colorectal cancer and weakly correlated with plasma suPAR, plasma PAI-1 and serum CEA

    DEFF Research Database (Denmark)

    Høgdall, Claus K; Christensen, Ib J; Stephens, Ross W

    2002-01-01

    PAR and CEA had a 2.43 increased risk as compared to a patient with median levels of these biochemical markers. Significant correlations were found with Dukes' stages for all the biochemical markers and between the respective biochemical markers. The findings confirm that TN is a strong prognostic factor...... activator (uPAR) and carcinoembryonic antigen (CEA). Significantly shorter survival was found for patients with TN levels below a cut-off point of 7.5 mg/l compared to patients with levels above, as illustrated by Kaplan-Meier curves. By Cox analyses, log TN, log soluble uPAR as well as log CEA were found...... to have an independent prognostic value for survival (log TN: HR = 0.47, 95% CI: 0.29-0.76); log soluble uPAR: HR = 1.65, 95% CI: 1.18-2.31; log CEA: HR = 1.I1, 95% CI: 1.03-1.20). Based on the multivariate model, a patient with a combination of low levels of TN and PAI-1 and elevated levels of soluble u...

  9. Carcinoma de glándulas sebáceas limitado a conjuntiva bulbar

    Directory of Open Access Journals (Sweden)

    Manuel Fernando Buitrago-Torrado

    Full Text Available El carcinoma de glándulas sebáceas es un tumor infrecuente que puede desarrollarse a partir de cualquier glándula sebácea en la piel. El 75 % de las veces es de origen ocular y afecta principalmente las glándulas de Zeiss, Meibomio y de la carúncula. Se caracteriza por un comportamiento agresivo, con alta probabilidad de invasión a piel, conjuntiva y córnea. Sin embargo, el compromiso de la conjuntiva como localización primaria es raro. Se presenta un caso con diagnóstico de carcinoma sebáceo de patrón nodular primario de la conjuntiva bulbar, atendido en el Hospital Universitario de Santander durante los años 2014-2016. El propósito del presente estudio es dar a conocer el caso de una patología infrecuente con pocos casos reportados en la literatura, enfatizar su importancia dentro de los diagnósticos diferenciales de masas en la conjuntiva y del estudio histopatológico como método para obtener un diagnóstico definitivo y realizar un abordaje temprano.

  10. Clinical value of multi-tumor markers detection with (CEA, CA19-9, CA72-4) for diagnosis of gastric malignancy

    International Nuclear Information System (INIS)

    Liu Yun; Li Jiangang

    2007-01-01

    Objective: To assess the clinical value of multi-tumor markers detection with (CEA, CA19-9, CA72-4) for diagnosis of gastric malignancy. Methods: Serum CEA, CA19-9, CA72-4 contents were measured with IRMA in 228 patients with gastric malignancies, 152 patients with benign gastric disorders and 200 controls. Results: The positive rates of single marker detection were all above 70% and that of CA72-4 was the highest (84.21%), next was CA19-9 (75.43%). Three tumor markers were all negative in only 4 cases (false negative rate was 1.75% ). So combined detection of 3 tumor markers could improve the positive rate to 98.25%. With combined determination of two markers, double positive rate for different sets of combinations was: 61.84% for CA72-4 + CA19-9, 51.31% for CA72-4 + CEA and 48.24% for CEA + CA19-9. Conclusion: It was suggested that for screening, CA72-4 was the first choice in single marker detections, and CA72-4 + CA19-9 was the first choice for combined detections of two markers. For follow-up, a combination of 2 markers with highest positive rate for the specific histopathologic type (i. e. carcinoma, leiomyosarcoma or lymphosarcoma) should be used throughout the study. (authors)

  11. Quantitative analysis of nickel in zirconium and zircaloy; Dosage du nickel dans le zirconium et dans le zircaloy

    Energy Technology Data Exchange (ETDEWEB)

    Rastoix, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    A rapid spectrophotometric has been developed for determination of 10 to 1000 ppm of Ni in zirconium and zircaloy using dimethylglyoxime. Iron, copper, tin and chromium, do not interfere at the concentration usually present in zirconium and its alloys. (author) [French] On determine colorimetriquenent 10 a 1000 ppm de Ni dans le zirconium et le zircaloy par photo colorimetrie a 440 m{mu} de la dimethylglyoxime nickelique. Le dosage est rapide. Le fer, le cuivre, l'etain, le chrome ne genent pas aux concentrations habituellement rencontrees dans le zirconium et ses alliages. (auteur)

  12. Use of integral experiments for the assessment of a new 235U IRSN-CEA evaluation

    Directory of Open Access Journals (Sweden)

    Ichou Raphaëlle

    2017-01-01

    Full Text Available The Working Party on International Nuclear Data Evaluation Co-operation (WPEC subgroup 29 (SG 29 was established to investigate an issue with the 235U capture cross-section in the energy range from 0.1 to 2.25 keV, due to a possible overestimation of 10% or more. To improve the 235U capture crosssection, a new 235U evaluation has been proposed by the Institut de Radioprotection et de Sûreté Nucléaire (IRSN and the CEA, mainly based on new time-of-flight 235U capture cross-section measurements and recent fission cross-section measurements performed at the n_TOF facility from CERN. IRSN and CEA Cadarache were in charge of the thermal to 2.25 keV energy range, whereas the CEA DIF was responsible of the high energy region. Integral experiments showing a strong 235U sensitivity are used to assess the new evaluation, using Monte-Carlo methods. The keff calculations were performed with the 5.D.1 beta version of the MORET 5 code, using the JEFF-3.2 library and the new 235U evaluation, as well as the JEFF-3.3T1 library in which the new 235U has been included. The benchmark selection allowed highlighting a significant improvement on keff due to the new 235U evaluation. The results of this data testing are presented here.

  13. Clinical experience of the radioimmunoscintigraphy with the 123-I-anti-CEA-Fab(No. 35)-fragment

    International Nuclear Information System (INIS)

    Meili, A.; Bekier, A.; Schulthess, G.K. von; Mach, J.P.

    1986-01-01

    Purified monoclonal murine 123-I-Fab-anti-CEA(Nr.35) were applied to 7 patients in a prospective study. Compared with the previous tested intact 131-I-labelled antibody (Nr. 202) the new preparation had many advantages for imaging: 2.7 times more counting efficiency of the gamma camera, higher activity utilizable and better accumulation in the tumor with sufficient image contrast in the ECT. Fifteen until sixteen hours after administration of 20 mCi 123-I the countrate in the pelvis was 130000/20 sec. In all patients the primary tumor was visualized, two patients demonstrated regional lymph node involvement and one patient liver metastasis in the left lobe. All findings were confirmed by surgery and histopathology. The average tumor/mucosa ratio was 3.5:1. The activity in the tumor 15 h after application was 0.015 per cent/g tumor/mCi 123-I used. 4/7 patients with colorectal cancer over 3.5 cm in diameter demonstrated normal plasma values of CEA < 3 microg/l. One patient with rising CEA plasma level was suspected of relapse, the focal accumulation corresponded with a mass lesion in the right sacrum in CT-scan. After the preliminary results the further applicability is recognizable: staging and screening before and after therapy, handicapped by high costs at time. A good advantage is the possibility of specific and organ independent diagnosis of tumor, which contents the corresponding surface antigen. (author)

  14. Le Bon, Gustave

    DEFF Research Database (Denmark)

    Borch, Christian

    2017-01-01

    Gustave Le Bon (1841–1931) was a French physician and crowd psychologist who published extensively on themes such as crowds, war, race, revolution, socialism, and war. His work on crowd psychology in particular was highly influential, including beyond scholarly circles. Le Bon argued that crowds...

  15. MR imaging, CT and CEA scintigraphy in the diagnosis of local recurrence of rectal carcinoma

    International Nuclear Information System (INIS)

    Blomqvist, L.; Holm, T.; Goeranson, H.; Jacobsson, H.; Ohlsen, H.; Larsson, S.A.

    1996-01-01

    Purpose: To compare advanced imaging techniques in the diagnosis of recurrent rectal cancer. Material and Methods: Twenty-five consecutive patients with either suspected or verified recurrence were examined by CT (n=25), MR with phased-array capabilities (n=24) and CEA scintigraphy (n=16). Three experienced radiologists (who were blinded to results obtained at surgery and histopathology) independently evaluated the films, one observer for each modality. Results: The MR radiologist arrived at a correct diagnosis in 87.5% of the examinations, the CT radiologist in 76% and the CEA radiologist in 75%. The MR radiologist's results correlated more often with reported pathology than did those of the CT radiologist with regard to the relation of recurrent tumor to surrounding structures in the pelvis. Conclusion: MR imaging is the most effective of the 3 modalities in the diagnosis of recurrent rectal cancer. (orig.)

  16. The diagnostic accuracy of a single CEA blood test in detecting colorectal cancer recurrence: Results from the FACS trial.

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    Full Text Available To evaluate the diagnostic accuracy of a single CEA (carcinoembryonic antigen blood test in detecting colorectal cancer recurrence.Patients who have undergone curative resection for primary colorectal cancer are typically followed up with scheduled CEA testing for 5 years. Decisions to investigate further (usually by CT imaging are based on single test results, reflecting international guidelines.A secondary analysis was undertaken of data from the FACS trial (two arms included CEA testing. The composite reference standard applied included CT-CAP imaging, clinical assessment and colonoscopy. Accuracy in detecting recurrence was evaluated in terms of sensitivity, specificity, likelihood ratios, predictive values, time-dependent area under the ROC curves, and operational performance when used prospectively in clinical practice are reported.Of 582 patients, 104 (17.9% developed recurrence during the 5 year follow-up period. Applying the recommended threshold of 5μg/L achieves at best 50.0% sensitivity (95% CI: 40.1-59.9%; in prospective use in clinical practice it would lead to 56 missed recurrences (53.8%; 95% CI: 44.2-64.4% and 89 false alarms (56.7% of 157 patients referred for investigation. Applying a lower threshold of 2.5μg/L would reduce the number of missed recurrences to 36.5% (95% CI: 26.5-46.5% but would increase the false alarms to 84.2% (924/1097 referred. Some patients are more prone to false alarms than others-at the 5μg/L threshold, the 89 episodes of unnecessary investigation were clustered in 29 individuals.Our results demonstrated very low sensitivity for CEA, bringing to question whether it could ever be used as an independent triage test. It is not feasible to improve the diagnostic performance of a single test result by reducing the recommended action threshold because of the workload and false alarms generated. Current national and international guidelines merit re-evaluation and options to improve performance, such as

  17. Preoperative serum levels of ca 72-4, cea, ca 19-9, and Alpha-fetoprotein in patients with gastric cancer Níveis séricos pré-operatórios de CA 72-4, CEA, CA 19-9 e Alfa-fetoproteína em pacientes com câncer gástrico

    Directory of Open Access Journals (Sweden)

    Rejane Mattar

    2002-06-01

    Full Text Available INTRODUCTION: The clinical importance of preoperative serum levels of CA 72-4, carcinoembryonic antigen (CEA, CA 19-9, and alpha-fetoprotein (AFP was prospectively evaluated in 44 patients with gastric cancer. METHOD: The serum tumor marker levels were determined by commercial radioimmunoassay kits. Positivity for CA 72-4 (>4 U/mL, CEA (>5 ng/mL, CA 19-9 (>37 U/mL, and AFP (>10 ng/mL were correlated according to the stage, histology, and lymph node metastasis. RESULTS AND DISCUSSION: CA 72-4 showed a higher positivity rate for gastric cancer (47.7% than CEA (25%, CA 19-9 (25%, and AFP (0%. The combination of CA 72-4 with CEA and CA 19-9 increased the sensitivity to 61.4%. The positivity rates of CA 72-4 in patients at stages I and II (initial disease and in patients at stages III and IV (advanced disease were 9% and 60.6%, respectively (P INTRODUÇÃO: A importância clínica dos níveis séricos pré-operatórios de CA 72-4, antígeno carcinoembrionário (CEA, CA 19-9 e alfa-fetoproteína (AFPfoi avaliada prospectivamente em 44 pacientes com câncer gástrico. MÉTODOS: Os marcadores tumorais foram quantificados com o emprego de kits comerciais de radioimunoensaio. A positividade dos marcadores, CA 72-4 (>4 U/ml, CEA (>5 ng/ml, CA 19-9 (>37 U/ml e AFP (>10 ng/ml, foi correlacionada com o estágio da doença, a histologia do tumor e comprometimento de linfonodo. RESULTADOS E DISCUSSÃO: O marcador CA 72-4 apresentou maior positividade para o câncer gástrico (47,7% que CEA (25%, CA 19-9 (25% e AFP (0%. A associação de CA 72-4, CEA e CA 19-9 aumentou a sensibilidade para 61,4%. A positividade do CA 72-4 nos pacientes com estágios I e II (Doença Inicial e nos pacientes com estágios III e IV (Doença Avançada foi de 9 e 60,6%, respectivamente (p<0,005. Não foi observada correlação entre os níveis séricos de CEA e CA 19-9 com o estágio do câncer gástrico. O CA 72-4 apresentou tendência de sugerir comprometimento de linfonodo, mas n

  18. Alpha waste incinerator at the Cea Valduc

    International Nuclear Information System (INIS)

    Anon.

    2000-01-01

    The Cea/Valduc has brought into operation an incinerator for alpha waste. The incineration is in two steps. The first one is a pyrolysis under reduction atmosphere in a furnace at 550 celsius degrees and the second one is a calcination under oxidizing atmosphere of the pyrolysis residue in a furnace at 900 celsius degrees. The ashes have less than 1% of carbon. The gas coming from incineration become oxidized at 1100 Celsius degrees, then are cooled, filtered to eliminate any track of radioactivity. Then, they are cleaned with a neutralisation process. The facility reduces the volume of waste in a factor 20. The capacity of treatment is 7 kg/h. The annual capacity is 30 m 3 . The investment represents 70 millions of francs and the cost of functioning is 2 M F by year. (N.C.)

  19. Le Conseil des gouverneurs | CRDI - Centre de recherches pour le ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2 nov. 2010 ... La gouvernance du CRDI. Reddition de comptes, transparence et efficacité. Au cours de l'exercice 2009–2010, le Conseil des gouverneurs du CRDI a adopté un nouveau cadre stratégique quinquennal, Le développement par l'innovation. Pendant de nombreux mois, les gouverneurs et les membres de la ...

  20. Le Service Accueil et Contrôle d'Accès

    CERN Document Server

    Ducastel, C

    1999-01-01

    L'utilisateur qui vient au CERN pour la première fois, est accueilli généralement par les membres du service 'Accueil et Contrôle d'Accès'. Cet utilisateur sera tout d'abord orienté vers un des postes d'hôtesses d'accueil en charge de l'enregistrement et de la délivrance de cartes CERN. Les informations seront saisies et immédiatement disponibles et transmises, via le système AMS, aux équipements de contrôle d'accès et à la Centrale de Surveillance des accès, chargée de la supervision de tout le dispositif de contrôle d'accès au domaine. Ces contrôles aux entrées et accueil des visiteurs individuels sont complétés par des missions de surveillance à l'intérieur du Domaine pour les agents, et par des travaux de gestions de dossiers administratifs (service enregistrement) pour les hôtesses. Un contrat commun assure une uniformité de formation des agents et hôtesses. Ce contrat est assorti d'une clause de Bonus Malus afin de tendre vers une optimisation des performances.