WorldWideScience

Sample records for cardiac pacing artificial

  1. Recent developments in cardiac pacing.

    Science.gov (United States)

    Rodak, D J

    1995-10-01

    Indications for cardiac pacing continue to expand. Pacing to improve functional capacity, which is now common, relies on careful patient selection and technical improvements, such as complex software algorithms and diagnostic capabilities.

  2. Application of rapid artificial cardiac pacing in thoracic endovascular aortic repair in aged patients

    Directory of Open Access Journals (Sweden)

    Chen J

    2013-12-01

    Full Text Available Jun Chen,1,* Wenhui Huang,2,* Songyuan Luo,2,* Dahao Yang,1 Zhengrong Xu,1 Jianfang Luo21Department of Angiocardiopathy, Affiliated Baoan Hospital of Southern Medical University, Shenzhen City, People's Republic of China; 2Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, People's Republic of China*These authors contributed equally to this workObjective: To compare the safety, efficacy, and impact on stent graft positioning between rapid artificial cardiac pacing (RACP, induced hypotension and sodium nitroprusside (SNP induced hypotension during thoracic endovascular aortic repair (TEVAR for Stanford B aortic dissection.Methods: One hundred and sixty-eight patients, who were diagnosed with Stanford B aortic dissection and who underwent selective TEVAR in Guangdong General Hospital and the People's Hospital of Baoan District, Shenzhen, People's Republic of China, were enrolled in this study. Patients were randomly divided into a RACP group (n=77 and a SNP group (n=91. During localization and deployment of the stent graft, hypotension was induced by RACP or intravenous SNP, according to randomization. Hemodynamics, landing precision (deviation from planned placement site, duration of procedure, renal function, neurocognitive function, and incidence of endoleaks and paraplegia/hemiplegia were compared. Except for methods of inducing hypotension, TEVAR was performed according to the same protocol in each group.Results: RACP was successfully performed in all patients assigned to the RACP group. Compared with the SNP group, blood pressure was significantly lower (43±5 versus 81±6 mmHg, P=0.003 and the restoration time of blood pressure and the operation duration were significantly shorter (7±2 versus 451±87 seconds, P<0.001; 87±15 versus 106±18 minutes, P<0.001, respectively in the RACP group. Stent graft localization/deployment was more precise in the RACP

  3. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  4. Impact of pacing modality and biventricular pacing on cardiac output and coronary conduit flow in the post-cardiotomy patient.

    LENUS (Irish Health Repository)

    Healy, David G

    2012-02-03

    We have previously demonstrated the role of univentricular pacing modalities in influencing coronary conduit flow in the immediate post-operative period in the cardiac surgery patient. We wanted to determine the mechanism of this improved coronary conduit and, in addition, to explore the possible benefits with biventricular pacing. Sixteen patients undergoing first time elective coronary artery bypass grafting who required pacing following surgery were recruited. Comparison of cardiac output and coronary conduit flow was performed between VVI and DDD pacing with a single right ventricular lead and biventricular pacing lead placement. Cardiac output was measured using arterial pulse waveform analysis while conduit flow was measured using ultrasonic transit time methodology. Cardiac output was greatest with DDD pacing using right ventricular lead placement only [DDD-univentricular 5.42 l (0.7), DDD-biventricular 5.33 l (0.8), VVI-univentricular 4.71 l (0.8), VVI-biventricular 4.68 l (0.6)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.023) and VVI-biventricular pacing (P=0.001) but there was no significant advantage to DDD-biventricular pacing (P=0.45). In relation to coronary conduit flow, DDD pacing again had the highest flow [DDD-univentricular 55 ml\\/min (24), DDD-biventricular 52 ml\\/min (25), VVI-univentricular 47 ml\\/min (23), VVI-biventricular 50 ml\\/min (26)]. DDD-univentricular pacing was significantly better than VVI-univentricular (P=0.006) pacing but not significantly different to VVI-biventricular pacing (P=0.109) or DDD-biventricular pacing (P=0.171). Pacing with a DDD modality offers the optimal coronary conduit flow by maximising cardiac output. Biventricular lead placement offered no significant benefit to coronary conduit flow or cardiac output.

  5. Temporary pacing

    Directory of Open Access Journals (Sweden)

    L.J. Workman

    1983-09-01

    Full Text Available Artificial cardiac pacing, the use of electrical stimuli to cause contraction of heart muscle, is a sophisticated therapeutic and diagnostic tool. Its rapid technologic improvement since first developed in the late 1930’s by Hyman, has made it possible not only to avoid certain cases of death due to heart block, but also to extend and improve the quality of life. Pacemaker therapy is generally used to treat heart rate or rhythm disturbances, being either tachy- or bradyarrhythmias that produce a detrimental drop in cardiac output. Of the many different types of pacemakers and electrodes currently available, ventricular demand pacing is the most commonly used.

  6. Leadless Cardiac Pacemakers: Current status of a modern approach in pacing

    Directory of Open Access Journals (Sweden)

    Skevos Sideris

    2017-11-01

    Full Text Available Since the first transvenous pacemaker implantation, which took place 50 years ago, important progress has been achieved in pacing technology. Consequently, at present, more than 700,000 pacemakers are implanted annually worldwide. However, conventional pacemakers' implantation has a non-negligible risk of periprocedural and long-term complications associated with the transvenous leads and pacemaker pocket. Recently, leadless pacing systems have emerged as a therapeutic alternative to conventional pacing systems that provide therapy for patients with bradyarrhythmias, while eliminating potential transvenous lead- and pacemaker pocket-related complications. Initial studies have demonstrated favorable efficacy and safety of currently developed leadless pacing systems, compared to transvenous pacemakers. In the present paper, we review the current evidence and highlight the advantages and disadvantages of this novel technology. New technological advances may allow the next generation of leadless pacemakers to further expand, thereby offering a wireless cardiac pacing in future. Keywords: cardiac pacing, pacemaker, leadless pacemaker, bradycardia

  7. The heart and cardiac pacing in Steinert disease.

    Science.gov (United States)

    Nigro, Gerardo; Papa, Andrea Antonio; Politano, Luisa

    2012-10-01

    Myotonic dystrophy (Dystrophia Myotonica, DM) is the most frequently inherited neuromuscular disease of adult life. It is a multisystemic disease with major cardiac involvement. Core features of myotonic dystrophy are myotonia, muscle weakness, cataract, respiratory failure and cardiac conduction abnormalities. Classical DM, first described by Steinert and called Steinert's disease or DM1 (Dystrophia Myotonica type 1) has been identified as an autosomal dominant disorder associated with the presence of an abnormal expansion of a CTG trinucleotide repeat in the 3' untranslated region of DMPK gene on chromosome 19. This review will mainly focus on the various aspects of cardiac involvement in DM1 patients and the current role of cardiac pacing in their treatment.

  8. Pneumothorax in cardiac pacing

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Johansen, Jens Brock; Nohr, Ellen Aagaard

    2012-01-01

    AIM: To identify risk factors for pneumothorax treated with a chest tube after cardiac pacing device implantation in a population-based cohort.METHODS AND RESULTS: A nationwide cohort study was performed based on data on 28 860 patients from the Danish Pacemaker Register, which included all Danish...... age was 77 years (25th and 75th percentile: 69-84) and 55% were male (n = 15 785). A total of 190 patients (0.66%) were treated for pneumothorax, which was more often in women [aOR 1.9 (1.4-2.6)], and in patients with age >80 years [aOR 1.4 (1.0-1.9)], a prior history of chronic obstructive pulmonary...

  9. Cardiac pacing systems and implantable cardiac defibrillators (ICDs): a radiological perspective of equipment, anatomy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K. E-mail: apqz59@dsl.pipex.comk1511@hotmail.com; Burchard, F.; Papouchado, M.; Wilde, P

    2004-08-01

    Cardiac pacing is a proven and effective treatment in the management of many cardiac arrhythmias. Implantable cardiac defibrillators (ICDs) are beneficial for certain patient groups with a history of serious, recurrent ventricular dysrhythmias, with a high risk of sudden cardiac death. Pacemaker devices take many forms and are highly visible on the chest radiograph. The radiographic appearances of ICDs and pacemakers can be similar and are subject to similar complications. The anatomical approach to the implantation, the type of device used and anatomical variations will all affect the appearance of these devices on the chest film. Pacemaker complications identified radiographically include pneumothorax, lead malpositioning, lead displacement or fracture, fracture of outer conductor coil, loose connection between the lead and pacemaker connector block, lack of redundant loops in paediatric patients and excessive manipulation of the device by the patient (Twiddler's syndrome). This pictorial review highlights the role of chest radiography in the diagnosis of post-cardiac pacing and ICD insertion complications, as well as demonstrating the normal appearances of the most frequently implanted devices.

  10. Extending the use of the pacing pulmonary artery catheter for safe minimally invasive cardiac surgery.

    Science.gov (United States)

    Levin, Ricardo; Leacche, Marzia; Petracek, Michael R; Deegan, Robert J; Eagle, Susan S; Thompson, Annemarie; Pretorius, Mias; Solenkova, Nataliya V; Umakanthan, Ramanan; Brewer, Zachary E; Byrne, John G

    2010-08-01

    In this study, the therapeutic use of pacing pulmonary artery catheters in association with minimally invasive cardiac surgery was evaluated. A retrospective study. A single institutional university hospital. Two hundred twenty-four consecutive patients undergoing minimally invasive cardiac surgery through a small (5-cm) right anterolateral thoracotomy using fibrillatory arrest without aortic cross-clamping. Two hundred eighteen patients underwent mitral valve surgery (97%) alone or in combination with other procedures. Six patients underwent other cardiac operations. In all patients, the pacing pulmonary artery catheter was used intraoperatively to induce ventricular fibrillation during the cooling period, and in the postoperative period it also was used in 37 (17%) patients who needed to be paced, mainly for bradyarrhythmias (51%). There were no complications related to the insertion of the catheters. Six (3%) patients experienced a loss of pacing capture, and 2 (1%) experienced another complication requiring the surgical removal of the catheter. Seven (3%) patients needed postoperative implantation of a permanent pacemaker. In combination with minimally invasive cardiac surgery, pacing pulmonary artery catheters were therapeutically useful to induce ventricular fibrillatory arrest intraoperatively and for obtaining pacing capability in the postoperative period. Their use was associated with a low number of complications. Copyright 2010 Elsevier Inc. All rights reserved.

  11. Hemodynamic stress testing using pacing tachycardia

    International Nuclear Information System (INIS)

    McKay, R.G.; Grossman, W.

    1986-01-01

    A trial pacing was first introduced in 1967 by Sowton and co-workers as a stress test which could be used in the cardiac catheterization laboratory to evaluate patients with schemic heart disease. Sowton noted that artificially increasing the heart rate by pacing the right atrium could usually induce angina in patients with symptomatic coronary artery disease. Since Sowton's original description, numerous investigators have described characteristic pacing-induced electrocardiographic changes, derangements of myocardial lactate metabolism, hemodynamic abnormalities, regional wall abnormalities, and defects in thallium scintigraphy. Although agreement on the overall usefulness of atrial pacing has not been uniform, it is clear that the technique can safely and reliably induce ischemia in most patients with coronary artery disease and that information obtained during the pacing-induced ischemic state can often be helpful in the diagnosis and treatment of the patient's underlying disease

  12. Determination of myocardial energetic output for cardiac rhythm pacing

    Czech Academy of Sciences Publication Activity Database

    Heřman, D.; Převorovská, Světlana; Maršík, František

    2007-01-01

    Roč. 7, č. 4 (2007), s. 156-161 ISSN 1567-8822 R&D Projects: GA ČR GA106/03/1073 Institutional research plan: CEZ:AV0Z20760514 Keywords : heart arrhythmia * cardiac pacing modes * numerical simulation Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  13. Cardiac optogenetic pacing in drosophila melanogaster using red-shifted opsins (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Electrical pacing is the current gold standard for investigation of mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, this method requires an invasive surgical procedure to implant the pacing electrodes. Recently, optogenetic pacing has been developed as an alternative, non-invasive method for heartbeat pacing in animals. It induces heartbeats by shining pulsed light on transgene-generated microbial opsins which in turn activate light gated ion channels in animal hearts. However, commonly used opsins, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we expressed recently engineered red-shifted opsins, ReaChR and CsChrimson, in the heart of a well-developed animal model, Drosophila melanogaster, for the first time. Optogenetic pacing was successfully conducted in both ReaChR and CsChrimson flies at their larval, pupal, and adult stages using 617 nm excitation light pulse, enabling a much deeper tissue penetration compared to blue stimulation light. A customized high speed and ultrahigh resolution OCM system was used to non-invasively monitor the heartbeat pacing in Drosophila. Compared to previous studies on optogenetic pacing of Drosophila, higher penetration depth of optogenetic excitation light was achieved in opaque late pupal flies. Lower stimulating power density is needed for excitation at each developmental stage of both groups, which improves the safety of this technique for heart rhythm studies.

  14. Earlier Right Ventricular Pacing in Cardiac Resynchronization Therapy for a Patient with Right Axis Deviation.

    Science.gov (United States)

    Hattori, Yusuke; Ishibashi, Kohei; Noda, Takashi; Okamura, Hideo; Kanzaki, Hideaki; Anzai, Toshihisa; Yasuda, Satoshi; Kusano, Kengo

    2017-09-01

    We describe the case of a 37-year-old woman who presented with complete right bundle branch block and right axis deviation. She was admitted to our hospital due to severe heart failure and was dependent on inotropic agents. Cardiac resynchronization therapy was initiated but did not improve her condition. After the optimization of the pacing timing, we performed earlier right ventricular pacing, which led to an improvement of her heart failure. Earlier right ventricular pacing should be considered in patients with complete right bundle branch block and right axis deviation when cardiac resynchronization therapy is not effective.

  15. 1998 survey of cardiac pacing in South Africa report of the working ...

    African Journals Online (AJOL)

    1998 survey of cardiac pacing in South Africa report of the working group on registries of the Cardiac Arrhythmia Society of South Africa (CASSA). RN Scott Millar. Abstract. No Abstract. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals ...

  16. Human technology after cardiac epigenesis. Artificial heart versus cardiac transplantation.

    Science.gov (United States)

    Losman, J G

    1977-09-24

    Cardiovascular disease is the chief cause of death in technologically advanced countries and accounts for more than 50% of all deaths in the USA. For a patient with end-stage cardiac failure the only treatment presently available is organ replacement, either by transplantation or by the use of a mechanical heart. Transplantation has demonstrated its value: survival of more than 8 years and restoration of a normal quality of life to patients who were in end-stage cardiac decompensation. However, the prospect of routine clinical application of an artificial heart remains distant. The development of a totally implantable artificial heart still presents a series of challenging engineering problems with regard to strict constraints of size, weight, blood-material compatibility, adaptability of output to demand, efficiency and reliability of the power supply, and safety if nuclear fuel is used. The totally artificial heart is presently not an alternative to the cardiac allograft, but could provide short-term support for patients awaiting cardiac transplantation.

  17. Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardia.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-08-01

    Imaging cardiac excitation within ventricular myocardium is important in the treatment of cardiac arrhythmias and might help improve our understanding of arrhythmia mechanisms. This study sought to rigorously assess the imaging performance of a 3-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of 3D intracardiac mapping from up to 216 intramural sites during paced rhythm and norepinephrine (NE)-induced ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in 13 healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous NE. Computed tomography images were obtained to construct geometry models. The noninvasively imaged activation sequence correlated well with invasively measured counterpart, with a correlation coefficient of 0.72 ± 0.04, and a relative error of 0.30 ± 0.02 averaged over 520 paced beats as well as 73 NE-induced PVCs and VT beats. All PVCs and VT beats initiated in the subendocardium by a nonreentrant mechanism. The averaged distance from the imaged site of initial activation to the pacing site or site of arrhythmias determined from intracardiac mapping was ∼5 mm. For dual-site pacing, the double origins were identified when they were located at contralateral sides of ventricles or at the lateral wall and the apex. 3DCEI can noninvasively delineate important features of focal or multifocal ventricular excitation. It offers the potential to aid in localizing the origins and imaging activation sequences of ventricular arrhythmias, and to provide noninvasive assessment of the underlying arrhythmia mechanisms. Copyright © 2011 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  18. MRI with cardiac pacing devices – Safety in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko, E-mail: touko.kaasalainen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Physics, University of Helsinki (Finland); Pakarinen, Sami, E-mail: sami.pakarinen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Kivistö, Sari, E-mail: sari.kivisto@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Holmström, Miia, E-mail: miia.holmstrom@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Hänninen, Helena, E-mail: helena.hanninen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Peltonen, Juha, E-mail: juha.peltonen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki (Finland); Lauerma, Kirsi, E-mail: kirsi.lauerma@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Sipilä, Outi, E-mail: outi.sipila@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland)

    2014-08-15

    Objectives: The aim of this study was to introduce a single centre “real life” experience of performing MRI examinations in clinical practice on patients with cardiac pacemaker systems. Additionally, we aimed to evaluate the safety of using a dedicated safety protocol for these patients. Materials and methods: We used a 1.5 T MRI scanner to conduct 68 MRI scans of different body regions in patients with pacing systems. Of the cardiac devices, 32% were MR-conditional, whereas the remaining 68% were MR-unsafe. We recorded the functional parameters of the devices prior, immediately after, and approximately one month after the MRI scanning, and compared the device parameters to the baseline values. Results: All MRI examinations were completed safely, and each device could be interrogated normally following the MRI. We observed no changes in the programmed parameters of the devices. For most of the participants, the distributions of the immediate and one-month changes in the device parameters were within 20% of the baseline values, although some changes approached clinically important thresholds. Furthermore, we observed no differences in the variable changes between MR-conditional and MR-unsafe pacing systems, or between scans of the thorax area and other scanned areas. Conclusion: MRI in patients with MR-conditional pacing systems and selected MR-unsafe systems could be performed safely under strict conditions in this study.

  19. Epicardial left ventricular lead placement for cardiac resynchronization therapy: optimal pace site selection with pressure-volume loops.

    Science.gov (United States)

    Dekker, A L A J; Phelps, B; Dijkman, B; van der Nagel, T; van der Veen, F H; Geskes, G G; Maessen, J G

    2004-06-01

    Patients in heart failure with left bundle branch block benefit from cardiac resynchronization therapy. Usually the left ventricular pacing lead is placed by coronary sinus catheterization; however, this procedure is not always successful, and patients may be referred for surgical epicardial lead placement. The objective of this study was to develop a method to guide epicardial lead placement in cardiac resynchronization therapy. Eleven patients in heart failure who were eligible for cardiac resynchronization therapy were referred for surgery because of failed coronary sinus left ventricular lead implantation. Minithoracotomy or thoracoscopy was performed, and a temporary epicardial electrode was used for biventricular pacing at various sites on the left ventricle. Pressure-volume loops with the conductance catheter were used to select the best site for each individual patient. Relative to the baseline situation, biventricular pacing with an optimal left ventricular lead position significantly increased stroke volume (+39%, P =.01), maximal left ventricular pressure derivative (+20%, P =.02), ejection fraction (+30%, P =.007), and stroke work (+66%, P =.006) and reduced end-systolic volume (-6%, P =.04). In contrast, biventricular pacing at a suboptimal site did not significantly change left ventricular function and even worsened it in some cases. To optimize cardiac resynchronization therapy with epicardial leads, mapping to determine the best pace site is a prerequisite. Pressure-volume loops offer real-time guidance for targeting epicardial lead placement during minimal invasive surgery.

  20. New method for cardiac resynchronization therapy: Transapical endocardial lead implantation for left ventricular free wall pacing

    NARCIS (Netherlands)

    I. Kassai (Imre); C. Foldesi (Csaba); A. Szekely (Andrea); T. Szili-Torok (Tamas)

    2008-01-01

    textabstractCoronary sinus lead placement for transvenous left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) has a significant failure rate at implant and a significant dislocation rate during follow-up. For these patients, epicardial pacing lead implantation is the most

  1. Diagnostic accuracy of pace spikes in the electrocardiogram to diagnose paced rhythm

    DEFF Research Database (Denmark)

    Andersson, Hedvig Bille; Hansen, Marco Bo; Thorsberger, Mads

    2015-01-01

    OBJECTIVE: To determine how often cardiac resynchronization therapy (CRT) pacing systems generate visible pace spikes in the electrocardiogram (ECG). METHODS: In 46 patients treated with CRT pacing systems, we recorded ECGs during intrinsic rhythm, atrial pacing and ventricular pacing. ECGs were...

  2. Managing innovation: lessons from the cardiac-pacing industry.

    Science.gov (United States)

    Gobeli, D H; Rudelius, W

    1985-01-01

    In this article, the authors argue that innovation is a surefire way for a firm to increase its sales and market share. This, in turn, can stimulate American industries and make American firms more competitive in international markets. Through their study of the cardiac-pacing industry, they draw conclusions about what factors contribute to a successful innovation in other industries besides medical electronics. They identify general patterns and stages of the innovation process, key roles top management must fill in an organization, and effective policies that foster important innovations.

  3. Optogenetic pacing in Drosophila melanogaster

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Tanzi, Rudolph E.; Zhou, Chao

    2015-01-01

    Electrical stimulation is currently the gold standard for cardiac pacing. However, it is invasive and nonspecific for cardiac tissues. We recently developed a noninvasive cardiac pacing technique using optogenetic tools, which are widely used in neuroscience. Optogenetic pacing of the heart provides high spatial and temporal precisions, is specific for cardiac tissues, avoids artifacts associated with electrical stimulation, and therefore promises to be a powerful tool in basic cardiac research. We demonstrated optogenetic control of heart rhythm in a well-established model organism, Drosophila melanogaster. We developed transgenic flies expressing a light-gated cation channel, channelrhodopsin-2 (ChR2), specifically in their hearts and demonstrated successful optogenetic pacing of ChR2-expressing Drosophila at different developmental stages, including the larva, pupa, and adult stages. A high-speed and ultrahigh-resolution optical coherence microscopy imaging system that is capable of providing images at a rate of 130 frames/s with axial and transverse resolutions of 1.5 and 3.9 μm, respectively, was used to noninvasively monitor Drosophila cardiac function and its response to pacing stimulation. The development of a noninvasive integrated optical pacing and imaging system provides a novel platform for performing research studies in developmental cardiology. PMID:26601299

  4. Using left-ventricular-only pacing to eliminate T-wave oversensing in a biventricular implantable cardiac defibrillator.

    Science.gov (United States)

    Khoo, Clarence; Bennett, Matthew; Chakrabarti, Santabhanu; LeMaitre, John; Tung, Stanley K K

    2013-02-01

    A man aged 75 years and with nonischemic cardiomyopathy had implantation of a biventricular implantable cardiac defibrillator (ICD). Consistent biventricular pacing was limited by intermittent T-wave oversensing (TWOS). A strategy of left-ventricular-only pacing was used to eliminate TWOS. This strategy obviates the need to reduce ventricular sensitivity and thus may be an effective alternative to biventricular pacing complicated by TWOS. Copyright © 2013 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. [The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association Arrhythmology Cardiac Pacing and cardiac pacing - annual report 2013].

    Science.gov (United States)

    Proclemer, Alessandro; Zecchin, Massimo; D'Onofrio, Antonio; Botto, Giovanni Luca; Rebellato, Luca; Ghidina, Marco; Bianco, Giulia; Bernardelli, Emanuela; Pucher, Elsa; Gregori, Dario

    2014-11-01

    The pacemaker (PM) and implantable cardioverter-defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) monitors the main epidemiological data in real-world practice. The survey for the 2013 activity collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. The Registry collects prospectively national PM and ICD implantation activity on the basis of European cards. PM Registry: data about 25 419 PM implantations were collected (19 134 first implant and 6285 replacements). The number of collaborating centers was 275. Median age of treated patients was 80 years (74 quartile I; 86 quartile III). ECG indications included atrioventricular conduction disorders in 43.6% of first PM implants, sick sinus syndrome in 24.7%, atrial fibrillation plus bradycardia in 12.9%, other in 18.8%. Among atrioventricular conduction defects, third-degree atrioventricular block was the most common type (23.2% of first implants). Use of single-chamber PMs was reported in 27.2% of first implants, of dual-chamber PMs in 62.6%, of PMs with cardiac resynchronization therapy (CRT) in 1.8%, and of single lead atrial-synchronized ventricular stimulation (VDD/R PMs) in 8.4%. ICD Registry: data about 16 519 ICD implantations were collected (11 474 first implants and 5045 replacements). The number of collaborating centers was 430. Median age of treated patients was 71 years (63 quartile I; 77 quartile III). Primary prevention indication was reported in 76% of first implants, secondary prevention in 24.0% (cardiac arrest in 7.8%). A single-chamber ICD was used in 27.2% of first implants, dual-chamber in 35.9% and biventricular in 36.8%. The PM and ICD Registry appears fundamental for monitoring PM and ICD utilization on a large national scale with rigorous examination of demographics and clinical indications. The PM Registry showed stable electrocardiographic

  6. Coronary grafts flow and cardiac pacing modalities: how to improve perioperative myocardial perfusion.

    LENUS (Irish Health Repository)

    D'Ancona, Giuseppe

    2012-02-03

    OBJECTIVE: Aim of this study was to investigate modifications of coronary grafts flow during different pacing modalities after CABG. MATERIALS AND METHODS: Two separate prospective studies were conducted in patients undergoing CABG and requiring intraoperative epicardial pacing. In a first study (22 patients) coronary grafts flows were measured during dual chamber pacing (DDD) and during ventricular pacing (VVI). In a second study (10 patients) flows were measured during DDD pacing at different atrio-ventricular (A-V) delay periods. A-V delay was adjusted in 25 ms increments from 25 to 250 ms and flow measurements were performed for each A-V delay increment. A transit time flowmeter was used for the measurements. RESULTS: An average of 3.4 grafts\\/patient were performed. In the first study, average coronary graft flow was 47.4+\\/-20.8 ml\\/min during DDD pacing and 41.8+\\/-18.2 ml\\/min during VVI pacing (P = 0.0004). Furthermore average systolic pressure was 94.3+\\/-10.1 mmHg during DDD pacing and 89.6+\\/-12.2 mmHg during VVV pacing (P = 0.0007). No significant differences in diastolic pressure were recorded during the two different pacing modalities. In the second study, maximal flows were achieved during DDD pacing with an A-V delay of 175 ms (54+\\/-9.6 ml\\/min) and minimal flows were detected at 25 ms A-V delay (38.1+\\/-4.7 ml\\/min) (P=ns). No significant differences in systolic or diastolic blood pressure were noticed during the different A-V delays. CONCLUSION: Grafts flowmetry provides an extra tool to direct supportive measures such as cardiac pacing after CABG. DDD mode with A-V delay around 175 ms. should be preferred to allow for maximal myocardial perfusion via the grafts.

  7. Optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    A non-invasive, contact-less cardiac pacing technology can be a powerful tool in basic cardiac research and in clinics. Currently, electrical pacing is the gold standard for cardiac pacing. Although highly effective in controlling the cardiac function, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its capabilities. Optical pacing of heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids shortcomings in electrical stimulation. Optical coherence tomography has been proved to be an effective technique in non-invasive imaging in vivo with ultrahigh resolution and imaging speed. In the last several years, non-invasive specific optical pacing in animal hearts has been reported in quail, zebrafish, and rabbit models. However, Drosophila Melanogaster, which is a significant model with orthologs of 75% of human disease genes, has rarely been studied concerning their optical pacing in heart. Here, we combined optogenetic control of Drosophila heartbeat with optical coherence microscopy (OCM) technique for the first time. The light-gated cation channel, channelrhodopsin-2 (ChR2) was specifically expressed by transgene as a pacemaker in drosophila heart. By stimulating the pacemaker with 472 nm pulsed laser light at different frequencies, we achieved non-invasive and more specific optical control of the Drosophila heart rhythm, which demonstrates the wide potential of optical pacing for studying cardiac dynamics and development. Imaging capability of our customized OCM system was also involved to observe the pacing effect visually. No tissue damage was found after long exposure to laser pulses, which proved the safety of optogenetic control of Drosophila heart.

  8. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    Energy Technology Data Exchange (ETDEWEB)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto [University Federico II, Department of Biomorphological and Functional Sciences, Institute of Biostructure and Bioimages of the National Council of Research, Naples (Italy); Duilio, Carlo; Santomauro, Maurizio [University Federico II, Department of Clinical Medicine, Cardiovascular and Immunological Sciences, Naples (Italy)

    2005-09-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction {>=}50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  9. Haemodynamic effects of dual-chamber pacing versus ventricular pacing during a walk test in patients with depressed or normal left ventricular function

    International Nuclear Information System (INIS)

    Ferro, Adele; Salvatore, Marco; Cuocolo, Alberto; Duilio, Carlo; Santomauro, Maurizio

    2005-01-01

    Dual-chamber rate-modulated pacing provides haemodynamic benefits compared with ventricular pacing at rest, but it is unclear whether this also holds true during physical exercise in patients with heart failure. This study assessed the haemodynamic response to a walk test during dual-chamber pacing and ventricular pacing in patients with depressed or normal left ventricular (LV) function. Twelve patients with an LV ejection fraction <50% and 11 patients with an LV ejection fraction ≥50% underwent two randomised 6-min walk tests under dual-chamber rate-modulated pacing and ventricular pacing at a fixed rate of 70 beats/min. All patients had a dual-chamber pacemaker implanted for complete heart block. LV function was monitored by a radionuclide ambulatory system. In patients with depressed LV function, the change from dual-chamber pacing to ventricular pacing induced a decrease in end-systolic volume at the peak of the walk test (P<0.05), with no difference in end-diastolic volume. As a consequence, higher increases in LV ejection fraction (P<0.0001) and stroke volume (P<0.01) were observed during ventricular pacing. No difference in cardiac output was found between the two pacing modes. In patients with normal LV function, the change from dual-chamber pacing to ventricular pacing induced a significant decrease in cardiac output (P<0.005 at rest and P<0.05 at the peak of the walk test). Compared with dual-chamber rate-modulated pacing, ventricular pacing improves cardiac function and does not affect cardiac output during physical activity in patients with depressed LV function, whereas it impairs cardiac output in those with normal function. (orig.)

  10. Relationship between seasonal weather changes, risk of dehydration, and incidence of severe bradyarrhythmias requiring urgent temporary transvenous cardiac pacing in an elderly population

    Science.gov (United States)

    Palmisano, Pietro; Accogli, Michele; Zaccaria, Maria; Vergari, Alessandra; De Luca De Masi, Gabriele; Negro, Luca; De Blasi, Sergio

    2014-09-01

    There is little information on any seasonal variations or meteorological factors associated with symptomatic bradyarrhythmias requiring cardiac pacing. The aim of this single-center study was to investigate the seasonal distribution of the incidence of severe, life-threatening bradyarrhythmias requiring urgent temporary transvenous cardiac pacing in an elderly population. Consecutive patients who underwent urgent temporary transvenous cardiac pacing between 2007 and 2012 were enrolled. The baseline characteristics of the patients and some meteorological parameters, including the calculation the daily heat index (HI), were recorded. During the study period, 79 consecutive patients (mean age 82 ± 8 years, 41 % male) underwent urgent temporary transvenous cardiac pacing, mainly for third-degree atrioventricular block (79 %). The incidence of bradyarrhythmias was significantly higher in summer than in the other seasons ( P 90 °F for >3 h per day for at least 10 days ( P renal function impairment and hyperkalemia (all P < 0.05). This study showed an increased incidence of severe bradyarrhythmias in an elderly population during the hottest months of the year. In these months, in subjects characterized by increased susceptibility to dehydration, the risk of developing bradyarrhythmias was increased significantly.

  11. Selection of permanent pacing position of cardiac ventricle in patients with complete right bundle branch block

    International Nuclear Information System (INIS)

    Yang Minquan; Zhou Jun; Zhu Yan; Wang Jin; Rong Xin; Zhang Xiaoyi

    2005-01-01

    Objective: To find out the optimal pacing localization by comparing different pacing positions of the right ventricle in brady-cardiacarrhythmia patients with complete right bundle branch block. Methods: DDD type of double lumen permanent pacemaker was implanted in each of the 8 cases of sick sinus syndrome (SSS) and/or III degree atrioventricular block (III degree AVB) with complete right bundle branch block in normal heart function or class I. For each patient, four pacing positions in right ventricle were compared and the QRS pacing durations were recorded. The position with the shortest the QRS duration was chosen as the permanent pacing position. Heart function, chest X-rays and left ventricle ejection fraction (LVEF) were followed up after the operation. Results: In all the 8 cases, the posterior septum of the right ventricle were chosen as the permanent pacing position, with the shorter pacing QRS duration than that of pre-operation (P<0.05) and other pacing positions of the right ventricle. All parameters of this permanent pacing position were within the normal range. During the follow-up of 6-36 months, no abnormity was found in cardiac functions. Conclusion: In brady-cardiacarrhythmia patients with complete right bundle branch block, the implantation of permanent pacemaker should be at the junction region of inlet and outlet tracts, of the posterior septum of the right ventricle with ideal physiological function. (authors)

  12. Comparison of right ventricular septal pacing and right ventricular apical pacing in patients receiving cardiac resynchronization therapy defibrillators: the SEPTAL CRT Study

    Science.gov (United States)

    Leclercq, Christophe; Sadoul, Nicolas; Mont, Lluis; Defaye, Pascal; Osca, Joaquim; Mouton, Elisabeth; Isnard, Richard; Habib, Gilbert; Zamorano, Jose; Derumeaux, Genevieve; Fernandez-Lozano, Ignacio; Dupuis, Jean-Marc; Rouleau, Frédéric; Tassin, Aude; Bordachar, Pierre; Clémenty, Jacques; Lafitte, Stephane; Ploux, Sylvan; Reant, Patricia; Ritter, Philippe; Defaye, Pascal; Jacon, Peggy; Mondesert, Blandine; Saunier, Carole; Vautrin, Estelle; Kacet, Salem; Guedon-Moreau, Laurence; Klug, Didier; Kouakam, Claude; Marechaux, Sylvestre; Marquie, Christelle; Polge, Anne Sophie; Richardson, Marjorie; Chevallier, Philippe; De Breyne, Brigitte; Lotek, Marcin M.; Nonin, Emilie; Pineau, Julien; Deharo, Jean-Claude; Bastard, Emilie; Franceschi, Frédéric; Habib, Gilbert; Jego, Christophe; Peyrouse, Eric; Prevot, Sebastien; Saint-Joseph, Hôpital; Bremondy, Michel; Faure, Jacques; Ferracci, Ange; Lefevre, Jean; Pisapia, Andre; Davy, Jean-Marc; Cransac, Frederic; Cung, Tien Tri; Georger, Frederic; Pasquie, Jean-Luc; Raczka, Franck; Sportouch-Dukhan, Catherine; Sadoul, Nicolas; Blangy, Hugues; Bruntz, Jean-François; Freysz, Luc; Groben, Laurent; Huttin, Olivier; Bammert, Antoine; Burban, Marc; Cebron, Jean-Pierre; Gras, Daniel; Frank, Robert; Duthoit, Guillaume; Hidden-Lucet, Françoise; Himbert, Caroline; Isnard, Richard; Lacotte, Jérôme; Pousset, Françoise; Zerah, Thierry; Leclercq, Christophe; Bellouin, Annaïk; Crocq, Christophe; Deplace, Christian; Donal, Erwan; Hamon, Cécile; Mabo, Philippe; Romain, Olivier; Solnon, Aude; Frederic, Anselme; Bauer, Fabrice; Bernard, Mathieu; Godin, Benedicte; Kurtz, Baptiste; Savoure, Arnaud; Copie, Xavier; Lascault, Gilles; Paziaud, Olivier; Piot, Olivier; Touche, Thierry; Delay, Toulouse Marc; Chilon, Talia; Detis, Nicolas; Duparc, Alexandre; Hebrard, Aurélien; Massabuau, Pierre; Maury, Philippe; Mondoly, Pierre; Rumeau, Philippe; Pasteur, Clinique; Boveda, Serge; Adrover, Laurence; Combes, Nicolas; Deplagne, Antoine; Marco-Baertich, Isabelle; Fondard, Olivier; Martínez, Juan Gabriel; Ibañez Criado, José Luis; Ortuño, Diego; Mont, Lluis; Berruezo, Antonio; Eduard, Belu; Martín, Ana; Merschon, Franco M.; Sitges, Marta; Tolosana, José María; Vidal, Bárbara; Hebron, H. Valle; i Mitjans, Angel Moya; Rodriguez, Oscar Alcalde; Rodriguez Palomares, José Fernando; Rivas, Nuria; Teixidó, Gisela; de Hierro, H. Puerta; Lozano, Ignacio Fernández; Ruiz Bautista, Maria Lorena; Castro, Victor; Cavero, Miguel Angel; Gutierrez, Carlos; Ros, Natalia; de la Victoria, H. Virgen; Alzueta Rodriguez, Francisco Javier; Cabrera, Fernando; Cordero, Alberto Barrera; Peña, José Luis; de Valme Sevilla, H.; Gonzáles, Juan Lealdel Ojo; Garcia Medina, Mª Dolores; Jiménez, Ricardo Pavón; Villagomez, David; de la Salud Toledo, H. Virgen; Castellanos Martinez, Eduardo; Alcalá, Juan; Maicas, Carolina; Arias Palomares, Miguel Angel; Puchol, Alberto; Valencia, H. La Fé; OscaAsensi, Joaquim; Carmona, Anastasio Quesada; De Carranza, Mª José Sancho-Tello; De Ros, José Olagüe; Pareja, Enrique Castro; Pérez, Oscar Cano; Saez, Ana Osa; Hortega, H. Rio; Guilarte, Benito Herreros; Muñoz San Jose, Juan Francisco; Pérez Sanz, Teresa Myriam; Logeart, Damien; Gil, Maria Lopez; Leclercq, Christophe; Lozano, Ignacio Fernandez; de Hierro, H. Puerta; Derumeaux, Genevieve

    2016-01-01

    Abstract Aims Cardiac resynchronization therapy (CRT) is a recommended treatment of heart failure (HF) patients with depressed left ventricular ejection fraction and wide QRS. The optimal right ventricular (RV) lead position being a matter of debate, we sought to examine whether RV septal (RVS) pacing was not inferior to RV apical (RVA) pacing on left ventricular reverse remodelling in patients receiving a CRT-defibrillator. Methods and results Patients (n = 263, age = 63.4 ± 9.5 years) were randomly assigned in a 1:1 ratio to RVS (n = 131) vs. RVA (n = 132) pacing. Left ventricular end-systolic volume (LVESV) reduction between baseline and 6 months was not different between the two groups (−25.3 ± 39.4 mL in RVS group vs. −29.3 ± 44.5 mL in RVA group, P = 0.79). Right ventricular septal pacing was not non-inferior (primary endpoint) to RVA pacing with regard to LVESV reduction (average difference = −4.06 mL; P = 0.006 with a −20 mL non-inferiority margin). The percentage of ‘echo-responders’ defined by LVESV reduction >15% between baseline and 6 months was similar in both groups (50%) with no difference in the time to first HF hospitalization or death (P = 0.532). Procedural or device-related serious adverse events occurred in 68 patients (RVS = 37) with no difference between the two groups (P = 0.401). Conclusion This study demonstrates that septal RV pacing in CRT is non-inferior to apical RV pacing for LV reverse remodelling at 6 months with no difference in the clinical outcome. No recommendation for optimal RV lead position can hence be drawn from this study. ClinicalTrials. gov number NCT 00833352. PMID:26374852

  13. A novel dynamic cardiac simulator utilizing pneumatic artificial muscle.

    Science.gov (United States)

    Liu, Hao; Yan, Jie; Zhou, Yuanyuan; Li, Hongyi; Li, Changji

    2013-01-01

    With the development of methods and skills of minimally invasive surgeries, equipments for doctors' training and practicing are in high demands. Especially for the cardiovascular surgeries, operators are requested to be familiar with the surgical environment of a beating heart. In this paper, we present a new dynamic cardiac simulator utilizing pneumatic artificial muscle to realize heartbeat. It's an artificial left ventricular of which the inner chamber is made of thermoplastic elastomers (TPE) with an anatomical structure of the real human heart. It is covered by another layer of material forming the artificial muscle which actuates the systole and diastole uniformly and omnidirectionally as the cardiac muscle does. Preliminary experiments were conducted to evaluate the performance of the simulator. The results indicated that the pressure at the terminal of the aorta could be controlled within the range of normal human systolic pressure, which quantitatively validated the new actuating mode of the heart-beating is effective.

  14. Alternative right ventricular pacing sites.

    Science.gov (United States)

    Łuciuk, Dariusz; Łuciuk, Marek; Gajek, Jacek

    2015-01-01

    The main adverse effect of chronic stimulation is stimulation-induced heart failure in case of ventricular contraction dyssynchrony. Because of this fact, new techniques of stimulation should be considered to optimize electrotherapy. One of these methods is pacing from alternative right ventricular sites. The purpose of this article is to review currently accumulated data about alternative sites of cardiac pacing. Medline and PubMed bases were used to search English and Polish reports published recently. Recent studies report a deleterious effect of long term apical pacing. It is suggested that permanent apical stimulation, by omitting physiological conduction pattern with His-Purkinie network, may lead to electrical and mechanical dyssynchrony of heart muscle contraction. In the long term this pathological situation can lead to severe heart failure and death. Because of this, scientists began to search for some alternative sites of cardiac pacing to reduce the deleterious effect of stimulation. Based on current accumulated data, it is suggested that the right ventricular outflow tract, right ventricular septum, direct His-bundle or biventricular pacing are better alternatives due to more physiological electrical impulse propagation within the heart and the reduction of the dyssynchrony effect. These methods should preserve a better left ventricular function and prevent the development of heart failure in permanent paced patients. As there is still not enough, long-term, randomized, prospective, cross-over and multicenter studies, further research is required to validate the benefits of using this kind of therapy. The article should pay attention to new sites of cardiac stimulation as a better and safer method of treatment.

  15. Vidarabine, an Anti-Herpes Virus Agent, Protects Against the Development of Heart Failure With Relatively Mild Side-Effects on Cardiac Function in a Canine Model of Pacing-Induced Dilated Cardiomyopathy.

    Science.gov (United States)

    Nakamura, Takashi; Fujita, Takayuki; Kishimura, Megumi; Suita, Kenji; Hidaka, Yuko; Cai, Wenqian; Umemura, Masanari; Yokoyama, Utako; Uechi, Masami; Ishikawa, Yoshihiro

    2016-11-25

    In heart failure patients, chronic hyperactivation of sympathetic signaling is known to exacerbate cardiac dysfunction. In this study, the cardioprotective effect of vidarabine, an anti-herpes virus agent, which we identified as a cardiac adenylyl cyclase inhibitor, in dogs with pacing-induced dilated cardiomyopathy (DCM) was evaluated. In addition, the adverse effects of vidarabine on basal cardiac function was compared to those of the β-blocker, carvedilol.Methods and Results:Vidarabine and carvedilol attenuated the development of pacing-induced systolic dysfunction significantly and with equal effectiveness. Both agents also inhibited the development of cardiac apoptosis and fibrosis and reduced the Na + -Ca 2+ exchanger-1 protein level in the heart. Importantly, carvedilol significantly enlarged the left ventricle and atrium; vidarabine, in contrast, did not. Vidarabine-treated dogs maintained cardiac response to β-AR stimulation better than carvedilol-treated dogs did. Vidarabine may protect against pacing-induced DCM with less suppression of basal cardiac function than carvedilol in a dog model. (Circ J 2016; 80: 2496-2505).

  16. [Artificial muscle and its prospect in application for direct cardiac compression assist].

    Science.gov (United States)

    Dong, Jing; Yang, Ming; Zheng, Zhejun; Yan, Guozheng

    2008-12-01

    Artificial heart is an effective device in solving insufficient native heart supply for heart transplant, and the research and application of novel actuators play an important role in the development of artificial heart. In this paper, artificial muscle is introduced as the actuators of direct cardiac compression assist, and some of its parameters are compared with those of native heart muscle. The open problems are also discussed.

  17. Automated Electrophysiology Makes the Pace for Cardiac Ion Channel Safety Screening

    Directory of Open Access Journals (Sweden)

    Clemens eMoeller

    2011-11-01

    Full Text Available The field of automated patch-clamp electrophysiology has emerged from the tension between the pharmaceutical industry’s need for high-throughput compound screening versus its need to be conservative due to regulatory requirements. On the one hand, hERG channel screening was increasingly requested for new chemical entities, as the correlation between blockade of the ion channel coded by hERG and Torsades de Pointes cardiac arrhythmia gained increasing attention. On the other hand, manual patch-clamping, typically quoted as the gold-standard for understanding ion channel function and modulation, was far too slow (and, consequently, too expensive for keeping pace with the numbers of compounds submitted for hERG channel investigations from pharmaceutical R&D departments. In consequence it became more common for some pharmaceutical companies to outsource safety pharmacological investigations, with a focus on hERG channel interactions. This outsourcing has allowed those pharmaceutical companies to build up operational flexibility and greater independence from internal resources, and allowed them to obtain access to the latest technological developments that emerged in automated patch-clamp electrophysiology – much of which arose in specialized biotech companies. Assays for nearly all major cardiac ion channels are now available by automated patch-clamping using heterologous expression systems, and recently, automated action potential recordings from stem-cell derived cardiomyocytes have been demonstrated. Today, most of the large pharmaceutical companies have acquired automated electrophysiology robots and have established various automated cardiac ion channel safety screening assays on these, in addition to outsourcing parts of their needs for safety screening.

  18. Cardiac pacing in heart failure patients with left bundle branch block: impact of pacing site for optimizing left ventricular resynchronization.

    Science.gov (United States)

    Pappone, C; Rosanio, S; Oreto, G; Tocchi, M; Gulletta, S; Salvati, A; Dicandia, C; Santinelli, V; Mazzone, P; Veglia, F; Ding, J; Sallusti, L; Spinelli, J; Vicedomini, G

    2000-07-01

    Acute left ventricular pacing has been associated with hemodynamic improvement in patients with congestive heart failure and wide QRS complex. We hypothesized that pacing two left ventricular sites simultaneously would produce faster activation and better systolic function than single-site pacing. We selected 14 heart failure patients (NYHA functional class III or IV) in normal sinus rhythm with left bundle branch block and QRS > 150 ms. An 8F dual micromanometer catheter was placed in the aorta for measuring +dP/dt (mmHg/s), aortic pulse pressure (mmHg), and end-diastolic pressure (mmHg). Pacing leads were positioned via coronary veins at the posterior base and lateral wall. Patients were acutely paced VDD at the posterior base, lateral wall, and both sites (dual-site) with 5 atrioventricular delays (from 8 ms to PR -30 ms). Pacing sequences were executed in randomized order using a custom external computer (FlexStim, Guidant CRM). Dual-site pacing increased peak +dP/dt significantly more than posterior base and lateral wall pacing. Dual-site and posterior base pacing raised aortic pulse pressure significantly more than lateral wall pacing. Dual-site pacing shortened QRS duration by 22 %, whereas posterior base and lateral wall pacing increased it by 2 and 12%, respectively (p = 0.006). In heart failure patients with left bundle branch block, dual-site pacing improves systolic function more than single-site stimulation. Improved ventricular activation synchrony, expressed by paced QRS narrowing, may account for the additional benefit of dual- vs single-site pacing in enhancing contractility. This novel approach deserves consideration for future heart failure pacing studies.

  19. Non-invasive red light optogenetic pacing and optical coherence microscopy (OCM) imaging for drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Men, Jing; Li, Airong; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2017-02-01

    Cardiac pacing could be a powerful tool for investigating mammalian cardiac electrical conduction systems as well as for treatment of certain cardiac pathologies. However, traditional electrical pacing using pacemaker requires an invasive surgical procedure. Electrical currents from the implanted electrodes can also cause damage to heart tissue, further restricting its utility. Optogenetic pacing has been developed as a promising, non-invasive alternative to electrical stimulation for controlling animal heart rhythms. It induces heart contractions by shining pulsed light on transgene-generated microbial opsins, which in turn activate the light gated ion channels in animal hearts. However, commonly used opsins in optogenetic pacing, such as channelrhodopsin-2 (ChR2), require short light wavelength stimulation (475 nm), which is strongly absorbed and scattered by tissue. Here, we performed optogenetic pacing by expression of recently engineered red-shifted microbial opsins, ReaChR and CsChrimson, in a well-established animal model, Drosophila melanogaster, using the 617 nm stimulation light pulses. The OCM technique enables non-invasive optical imaging of animal hearts with high speed and ultrahigh axial and transverse resolutions. We integrated a customized OCM system with the optical stimulation system to monitor the optogenetic pacing noninvasively. The use of red-sifted opsins enabled deeper penetration of simulating light at lower power, which is promising for applications of optogenetic pacing in mammalian cardiac pathology studies or clinical treatments in the future.

  20. Ischemic Stroke with Cardiac Pacemaker Implantation: Comparison of Physiological and Ventricular Pacing Modes.

    Science.gov (United States)

    Kato, Yuji; Hayashi, Takeshi; Kato, Ritsushi; Tanahashi, Norio; Takao, Masaki

    2017-09-01

    The clinical characteristics of ischemic stroke in patients with a pacemaker (PM) are not well understood. Forty-six ischemic stroke patients with a PM were investigated retrospectively, and the impact of different pacing modes was compared. The patients were divided into a physiological pacing group (n = 22) and a ventricular pacing group (n = 24). The prevalence of atrial fibrillation (AF) was significantly higher in the ventricular pacing group (36% versus 75%; P = .008). The mean left atrial dimension was relatively large in the ventricular pacing group than in the physiological pacing group (44.5 ± 6.7 mm versus 39.1 ± 8.5 mm, respectively; P = .071). Twenty-four percent of the patients were receiving anticoagulants, whereas 41% of the patients were receiving antiplatelet drugs. Cardioembolism was the most common stroke subtype in both groups. Although there was no statistically significant difference, neurological severity on admission was higher in the ventricular pacing group than in the physiological pacing group (P = .061). Functional outcomes, excluding patients with transient ischemic attack or prior stroke, significantly declined in the ventricular pacing group compared with the physiological pacing group (P = .044). The avoidance of the ventricular pacing mode may result in improved clinical outcomes. In patients without persistent AF, it may be important to select physiological pacing instead of ventricular pacing to decrease potential stroke severity. Copyright © 2017 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  1. Simple and effective solution for diaphragm pacing by that uses the transvenous femoral approach in a patient treated with cardiac resynchronization-defibrillator therapy: The wrapping method

    Directory of Open Access Journals (Sweden)

    Ahmet Taha Alper, Prof.

    2017-08-01

    Full Text Available The use of cardiac resynchronization therapy (CRT has become widespread in patients with heart failure who meet the criteria for implantation. Coronary sinus lead positioning is important to provide the intended biventricular stimulation. Diaphragm pacing is a lead-related complication which occurs secondary to phrenic nerve stimulation. We present the case of a 58-year-old male patient who had diaphragm pacing after CRT with defibrillator implantation. The complication was resolved by using the transvenous femoral approach with the wrapping method.

  2. Clinically oriented device programming in bradycardia patients: part 1 (sinus node disease). Proposals from AIAC (Italian Association of Arrhythmology and Cardiac Pacing).

    Science.gov (United States)

    Ziacchi, Matteo; Palmisano, Pietro; Biffi, Mauro; Ricci, Renato P; Landolina, Maurizio; Zoni-Berisso, Massimo; Occhetta, Eraldo; Maglia, Giampiero; Botto, Gianluca; Padeletti, Luigi; Boriani, Giuseppe

    2018-04-01

    : Modern pacemakers have an increasing number of programable parameters and specific algorithms designed to optimize pacing therapy in relation to the individual characteristics of patients. When choosing the most appropriate pacemaker type and programing, the following variables must be taken into account: the type of bradyarrhythmia at the time of pacemaker implantation; the cardiac chamber requiring pacing, and the percentage of pacing actually needed to correct the rhythm disorder; the possible association of multiple rhythm disturbances and conduction diseases; the evolution of conduction disorders during follow-up. The goals of device programing are to preserve or restore the heart rate response to metabolic and hemodynamic demands; to maintain physiological conduction; to maximize device longevity; to detect, prevent, and treat atrial arrhythmia. In patients with sinus node disease, the optimal pacing mode is DDDR. Based on all the available evidence, in this setting, we consider appropriate the activation of the following algorithms: rate responsive function in patients with chronotropic incompetence; algorithms to maximize intrinsic atrioventricular conduction in the absence of atrioventricular blocks; mode-switch algorithms; algorithms for autoadaptive management of the atrial pacing output; algorithms for the prevention and treatment of atrial tachyarrhythmias in the subgroup of patients with atrial tachyarrhythmias/atrial fibrillation. The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features.

  3. Myocardial function during transesophageal cardiac pacing in patients with coronary heart diseases when selected for surgical management: nuclear stethoscopic findings

    International Nuclear Information System (INIS)

    Fitilev, S.B.; Mironova, M.A.; Gordeev, V.F.; Satrapinskij, V.Yu.; Badalyan, E.A.; Akademiya Meditsinskikh Nauk SSSR, Moscow

    1991-01-01

    Studies of myocardial function during transesophageal cardiac pacing (TECP) were carried out in 70 patients with coronary heart diseases (CHD). All the patients were examined for central and intracardiac hemodynamics during TECP using nuclear stetoscope Bios (USA). The obtained data of central hemodynamics and myocardium contractibility make it possible to judge not only of pathological hemodynamics changes, as a CHD diagnostic factor, but of factors limiting reserve of cardiovascular system as well, depending on morphological heart changes

  4. Prognostic value of atrial pacing and thallium-201 scintigraphy in patients with stable chest pain

    International Nuclear Information System (INIS)

    Stratmann, H.G.; Mark, A.L.; Walter, K.E.; Williams, G.A.

    1989-01-01

    The value of atrial pacing and thallium-201 scintigraphy for assessing risk of subsequent cardiac events was examined in 210 patients with stable chest pain. Follow-up information was complete in 195 patients (mean age 61 years). Over an average follow-up of 19 months, cardiac events occurred in 38 patients--unstable angina in 20, nonfatal acute myocardial infarction in 6 and death from cardiac causes in 12. A history of previous myocardial infarction, diabetes mellitus, systemic hypertension or peripheral vascular disease at the time of pacing was not associated with an increased frequency of subsequent cardiac events. Six of 38 patients with later cardiac events had a history of congestive heart failure, compared with 8 of 157 without cardiac events (p less than 0.05). Neither pacing-induced angina, ST depression, nor the presence of a fixed perfusion defect was significantly more frequent in patients with cardiac events as a whole compared with patients without such events. Reversible defects and abnormal scans (reversible or fixed defects) were present, respectively, in 19 and 31 of 38 patients with cardiac events, compared with 42 and 79 patients, respectively, of the 157 patients without cardiac events (both p less than 0.01). In patients who developed unstable angina, a reversible defect was seen in 13 and an abnormal scan in 16 (both p less than 0.01 compared with patients without cardiac events). In 12 patients who died from a primary cardiac event, fixed defects were present in 8 and an abnormal scan in 11 (p less than 0.05 and p less than 0.01, respectively, compared with patients without cardiac events)

  5. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the rabbit heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2011-01-01

    Ventricular arrhythmias represent one of leading causes for sudden cardiac death, a significant problem in public health. Noninvasive imaging of cardiac electric activities associated with ventricular arrhythmias plays an important role in better our understanding of the mechanisms and optimizing the treatment options. The present study aims to rigorously validate a novel three-dimensional (3-D) cardiac electrical imaging (3-DCEI) technique with the aid of 3-D intra-cardiac mapping during paced rhythm and ventricular tachycardia (VT) in the rabbit heart. Body surface potentials and intramural bipolar electrical recordings were simultaneously measured in a closed-chest condition in thirteen healthy rabbits. Single-site pacing and dual-site pacing were performed from ventricular walls and septum. VTs and premature ventricular complexes (PVCs) were induced by intravenous norepinephrine (NE). The non-invasively imaged activation sequence correlated well with invasively measured counterparts, with a correlation coefficient of 0.72 and a relative error of 0.30 averaged over all paced beats and NE-induced PVCs and VT beats. The averaged distance from imaged site of initial activation to measured site determined from intra-cardiac mapping was ∼5mm. These promising results suggest that 3-DCEI is feasible to non-invasively localize the origins and image activation sequence of focal ventricular arrhythmias.

  6. Short-term action potential memory and electrical restitution: A cellular computational study on the stability of cardiac repolarization under dynamic pacing.

    Directory of Open Access Journals (Sweden)

    Massimiliano Zaniboni

    Full Text Available Electrical restitution (ER is a major determinant of repolarization stability and, under fast pacing rate, it reveals memory properties of the cardiac action potential (AP, whose dynamics have never been fully elucidated, nor their ionic mechanisms. Previous studies have looked at ER mainly in terms of changes in AP duration (APD when the preceding diastolic interval (DI changes and described dynamic conditions where this relationship shows hysteresis which, in turn, has been proposed as a marker of short-term AP memory and repolarization stability. By means of numerical simulations of a non-propagated human ventricular AP, we show here that measuring ER as APD versus the preceding cycle length (CL provides additional information on repolarization dynamics which is not contained in the companion formulation. We focus particularly on fast pacing rate conditions with a beat-to-beat variable CL, where memory properties emerge from APD vs CL and not from APD vs DI and should thus be stored in APD and not in DI. We provide an ion-currents characterization of such conditions under periodic and random CL variability, and show that the memory stored in APD plays a stabilizing role on AP repolarization under pacing rate perturbations. The gating kinetics of L-type calcium current seems to be the main determinant of this safety mechanism. We also show that, at fast pacing rate and under otherwise identical pacing conditions, a periodically beat-to-beat changing CL is more effective than a random one in stabilizing repolarization. In summary, we propose a novel view of short-term AP memory, differentially stored between systole and diastole, which opens a number of methodological and theoretical implications for the understanding of arrhythmia development.

  7. Improvement of Left Ventricular Function by Permanent Direct His-Bundle Pacing in a Case with Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Yukiko Sashida, MD

    2006-01-01

    Full Text Available The patient was a 67-year-old female diagnosed with dilated cardiomyopathy. She had chronic atrial fibrillation (AF with bradycardia and low left ventricular function (left ventricular ejection fraction (LVEF 40%. She was admitted for congestive heart failure. She remained New York Heart Association (NYHA functional class III due to AF bradycardia. Pacemaker implantation was necessary for treatment of heart failure and administration of dose intensive β-blockers. As she had normal His-Purkinje activation, we examined the optimal pacing sites. Hemodynamics of His-bundle pacing and biventricular pacing were compared. Pulmonary capillary wedge pressure (PCWP was significantly lower on Hisbundle pacing than right ventricular (RV apical pacing and biventricular pacing (13mmHg, 19mmHg, and 19mmHg, respectively with an almost equal cardiac index. Based on the examination we implanted a permanent pacemaker for Direct His-bundle pacing (DHBP. After the DHBP implantation, the LVEF immediately improved from 40% to 55%, and BNP level decreased from 422 pg/ml to 42 pg/ml. The number of premature ventricular complex (PVC was decreased, and non sustained ventricular tachycardia (NSVT disappeared. Pacing threshold for His-bundle pacing has remained at the same level. His-bundle pacing has been maintained during 27 months and her long-term DHBP can improve cardiac function and the NYHA functional class.

  8. Multimodality imaging to guide cardiac interventional procedures

    NARCIS (Netherlands)

    Tops, Laurens Franciscus

    2010-01-01

    In recent years, a number of new cardiac interventional procedures have been introduced. Catheter ablation procedures for atrial fibrillation (AF) have been refined and are now considered a good treatment option in patients with drug-refractory AF. In cardiac pacing, cardiac resynchronization

  9. Toward a More Efficient Implementation of Antifibrillation Pacing.

    Directory of Open Access Journals (Sweden)

    Dan Wilson

    Full Text Available We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing.

  10. Toward a More Efficient Implementation of Antifibrillation Pacing

    Science.gov (United States)

    Wilson, Dan; Moehlis, Jeff

    2016-01-01

    We devise a methodology to determine an optimal pattern of inputs to synchronize firing patterns of cardiac cells which only requires the ability to measure action potential durations in individual cells. In numerical bidomain simulations, the resulting synchronizing inputs are shown to terminate spiral waves with a higher probability than comparable inputs that do not synchronize the cells as strongly. These results suggest that designing stimuli which promote synchronization in cardiac tissue could improve the success rate of defibrillation, and point towards novel strategies for optimizing antifibrillation pacing. PMID:27391010

  11. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  12. The heart and cardiac pacing in Steinert disease

    OpenAIRE

    NIGRO, GERARDO; PAPA, ANDREA ANTONIO; POLITANO, LUISA

    2012-01-01

    Myotonic dystrophy (Dystrophia Myotonica, DM) is the most frequently inherited neuromuscular disease of adult life. It is a multisystemic disease with major cardiac involvement. Core features of myotonic dystrophy are myotonia, muscle weakness, cataract, respiratory failure and cardiac conduction abnormalities. Classical DM, first described by Steinert and called Steinert's disease or DM1 (Dystrophia Myotonica type 1) has been identified as an autosomal dominant disorder associated with the p...

  13. Intrinsic cardiac nervous system in tachycardia induced heart failure.

    Science.gov (United States)

    Arora, Rakesh C; Cardinal, Rene; Smith, Frank M; Ardell, Jeffrey L; Dell'Italia, Louis J; Armour, J Andrew

    2003-11-01

    The purpose of this study was to test the hypothesis that early-stage heart failure differentially affects the intrinsic cardiac nervous system's capacity to regulate cardiac function. After 2 wk of rapid ventricular pacing in nine anesthetized canines, cardiac and right atrial neuronal function were evaluated in situ in response to enhanced cardiac sensory inputs, stimulation of extracardiac autonomic efferent neuronal inputs, and close coronary arterial administration of neurochemicals that included nicotine. Right atrial neuronal intracellular electrophysiological properties were then evaluated in vitro in response to synaptic activation and nicotine. Intrinsic cardiac nicotine-sensitive, neuronally induced cardiac responses were also evaluated in eight sham-operated, unpaced animals. Two weeks of rapid ventricular pacing reduced the cardiac index by 54%. Intrinsic cardiac neurons of paced hearts maintained their cardiac mechano- and chemosensory transduction properties in vivo. They also responded normally to sympathetic and parasympathetic preganglionic efferent neuronal inputs, as well as to locally administered alpha-or beta-adrenergic agonists or angiotensin II. The dose of nicotine needed to modify intrinsic cardiac neurons was 50 times greater in failure compared with normal preparations. That dose failed to alter monitored cardiovascular indexes in failing preparations. Phasic and accommodating neurons identified in vitro displayed altered intracellular membrane properties compared with control, including decreased membrane resistance, indicative of reduced excitability. Early-stage heart failure differentially affects the intrinsic cardiac nervous system's capacity to regulate cardiodynamics. While maintaining its capacity to transduce cardiac mechano- and chemosensory inputs, as well as inputs from extracardiac autonomic efferent neurons, intrinsic cardiac nicotine-sensitive, local-circuit neurons differentially remodel such that their capacity to

  14. Modelling far field pacing for terminating spiral waves pinned to ischaemic heterogeneities in cardiac tissue

    Science.gov (United States)

    Boccia, E.; Luther, S.

    2017-01-01

    In cardiac tissue, electrical spiral waves pinned to a heterogeneity can be unpinned (and eventually terminated) using electric far field pulses and recruiting the heterogeneity as a virtual electrode. While for isotropic media the process of unpinning is much better understood, the case of an anisotropic substrate with different conductivities in different directions still needs intensive investigation. To study the impact of anisotropy on the unpinning process, we present numerical simulations based on the bidomain formulation of the phase I of the Luo and Rudy action potential model modified due to the occurrence of acute myocardial ischaemia. Simulating a rotating spiral wave pinned to an ischaemic heterogeneity, we compare the success of sequences of far field pulses in the isotropic and the anisotropic case for spirals still in transient or in steady rotation states. Our results clearly indicate that the range of pacing parameters resulting in successful termination of pinned spiral waves is larger in anisotropic tissue than in an isotropic medium. This article is part of the themed issue ‘Mathematical methods in medicine: neuroscience, cardiology and pathology’. PMID:28507234

  15. Validation of measurements of Fourier phase and amplitude analysis of technetium99 gated cardiac scans using artificial hearts

    International Nuclear Information System (INIS)

    Yiannikas, J.; Takatani, S.; MacIntyre, W.J.; Underwood, D.A.; Cook, S.A.; Go, R.T.; Napoli, C.; Nose, Y.

    1982-01-01

    The use of artificial hearts, developed for total heart replacement programs, allows assessment of the accuracy of measuring the first Fourier component phase and amplitude when applied to gated cardiac technetium 99 scans. In the extreme example of asynchrony of ventricular contraction in coronary artery disease that of ventricular aneurysms, the first Fourier component measurements of amplitude were highly correlated to volume increases suggesting that the calculated amplitude accurately reflects volume changes. The calculated asynchrony using Fourier analysis of the gated technetium 99 studies of two artificial hearts was highly accurate when compared to the predetermined calculation of phase angle difference and hence degree of asynchrony. The studies suggest that measurement of phase and amplitude using the first Fourier component of time-activity waves of gated cardiac technetium 99 studies accurately measure degree of asynchrony and volume changes respectively

  16. [Management of surgery patients with implanted cardiac pacemakers].

    Science.gov (United States)

    Ugljen, R; Dadić, D; Ferek-Petrić, B; Jelić, I; Letica, D; Anić, D; Husar, J

    1995-01-01

    Patients having cardiac pacemaker implanted may be subjected to various general surgery procedures. Application of electrosurgery for the purpose of resection and coagulation, provides a high frequency electric field which produces electric voltage on the electrodes of the pacing system. This voltage may be detected within the pacing system, and various arrhythmias can be provoked in correlation with underlying rhythm and mode of pacing. Preoperative patient control and proper pacemaker programming can prevent the pacing malfunctions due to the electrosurgery application. Appropriate positioning of the neutral electrode in relation to the pacing system avoids the electric fields intersection and decreases their interference.

  17. Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study.

    Science.gov (United States)

    Siciliano, Mariachiara; Migliore, Federico; Badano, Luigi; Bertaglia, Emanuele; Pedrizzetti, Gianni; Cavedon, Stefano; Zorzi, Alessandro; Corrado, Domenico; Iliceto, Sabino; Muraru, Denisa

    2017-11-01

    To characterize the effect of multipoint pacing (MPP) compared to biventricular pacing (BiV) on left ventricle (LV) mechanics and intraventricular fluid dynamics by three-dimensional echocardiography (3DE) and echocardiographic particle imaging velocimetry (Echo-PIV). In 11 consecutive patients [8 men; median age 65 years (57-75)] receiving cardiac resynchronization therapy (CRT) with a quadripolar LV lead (Quartet,St.Jude Medical,Inc.), 3DE and Echo-PIV data were collected for each pacing configuration (CRT-OFF, BiV, and MPP) at follow-up after 6 months. 3DE data included LV volumes, LV ejection fraction (LVEF), strain, and systolic dyssynchrony index (SDI). Echo-PIV was used to evaluate the directional distribution of global blood flow momentum, ranging from zero, when flow force is predominantly along the base-apex direction, up to 90° when it becomes transversal. MPP resulted in significant reduction in end-diastolic and end-systolic volumes compared with both CRT-OFF (P = 0.02; P = 0.008, respectively) and BiV (P = 0.04; P = 0.03, respectively). LVEF and cardiac output were significant superior in MPP compared with CRT-OFF, but similar between MPP and BiV. Statistical significant differences when comparing global longitudinal and circumferential strain and SDI with MPP vs. CRT-OFF were observed (P = 0.008; P = 0.008; P = 0.01, respectively). There was also a trend towards improvement in strain between BiV and MPP that did not reach statistical significance. MPP reflected into a significant reduction of the deviation of global blood flow momentum compared with both CRT-OFF and BiV (P = 0.002) indicating a systematic increase of longitudinal alignment from the base-apex orientation of the haemodynamic forces. These preliminary results suggest that MPP resulted in significant improvement of LV mechanics and fluid dynamics compared with BiV. However, larger studies are needed to confirm this hypothesis. © Crown copyright 2016.

  18. Theory of the development of alternans in the heart during controlled diastolic interval pacing

    Science.gov (United States)

    Otani, Niels F.

    2017-09-01

    The beat-to-beat alternation in action potential durations (APDs) in the heart, called APD alternans, has been linked to the development of serious cardiac rhythm disorders, including ventricular tachycardia and fibrillation. The length of the period between action potentials, called the diastolic interval (DI), is a key dynamical variable in the standard theory of alternans development. Thus, methods that control the DI may be useful in preventing dangerous cardiac rhythms. In this study, we examine the dynamics of alternans during controlled-DI pacing using a series of single-cell and one-dimensional (1D) fiber models of alternans dynamics. We find that a model that combines a so-called memory model with a calcium cycling model can reasonably explain two key experimental results: the possibility of alternans during constant-DI pacing and the phase lag of APDs behind DIs during sinusoidal-DI pacing. We also find that these results can be replicated by incorporating the memory model into an amplitude equation description of a 1D fiber. The 1D fiber result is potentially concerning because it seems to suggest that constant-DI control of alternans can only be effective over only a limited region in space.

  19. An integrated optical coherence microscopy imaging and optical stimulation system for optogenetic pacing in Drosophila melanogaster (Conference Presentation)

    Science.gov (United States)

    Alex, Aneesh; Li, Airong; Men, Jing; Jerwick, Jason; Tanzi, Rudolph E.; Zhou, Chao

    2016-03-01

    Electrical stimulation is the clinical standard for cardiac pacing. Although highly effective in controlling cardiac rhythm, the invasive nature, non-specificity to cardiac tissues and possible tissue damage limits its applications. Optogenetic pacing of the heart is a promising alternative, which is non-invasive and more specific, has high spatial and temporal precision, and avoids the shortcomings in electrical stimulation. Drosophila melanogaster, which is a powerful model organism with orthologs of nearly 75% of human disease genes, has not been studied for optogenetic pacing in the heart. Here, we developed a non-invasive integrated optical pacing and optical coherence microscopy (OCM) imaging system to control the heart rhythm of Drosophila at different developmental stages using light. The OCM system is capable of providing high imaging speed (130 frames/s) and ultrahigh imaging resolutions (1.5 μm and 3.9 μm for axial and transverse resolutions, respectively). A light-sensitive pacemaker was developed in Drosophila by specifically expressing the light-gated cation channel, channelrhodopsin-2 (ChR2) in transgenic Drosophila heart. We achieved non-invasive and specific optical control of the Drosophila heart rhythm throughout the fly's life cycle (larva, pupa, and adult) by stimulating the heart with 475 nm pulsed laser light. Heart response to stimulation pulses was monitored non-invasively with OCM. This integrated non-invasive optogenetic control and in vivo imaging technique provides a novel platform for performing research studies in developmental cardiology.

  20. Sentence Processing in an Artificial Language: Learning and Using Combinatorial Constraints

    Science.gov (United States)

    Amato, Michael S.; MacDonald, Maryellen C.

    2010-01-01

    A study combining artificial grammar and sentence comprehension methods investigated the learning and online use of probabilistic, nonadjacent combinatorial constraints. Participants learned a small artificial language describing cartoon monsters acting on objects. Self-paced reading of sentences in the artificial language revealed comprehenders'…

  1. Effects of Cardiac Resynchronization Therapy on the Arrhythmic Substrate in a Patient with Long QT and Torsades de pointes

    Directory of Open Access Journals (Sweden)

    Masayasu Ikutomi, MD

    2011-01-01

    Full Text Available We describe a patient with torsades de pointes (TdP who was implanted with cardiac resynchronization therapy defibrillator (CRT-D. At the time of CRT-D implantation, left ventricular (LV epicardial pacing exacerbated TdPs and developed into electrical storm, which was triggered even by biventricular pacing. We needed to inactivate the LV lead for 2 weeks. At the next device check testing of LV pacing still induced TdPs, whe reas biventricular pacing did not. After starting the continuous biventricular pacing no ventricular arrhythmias happened, and furthermore the QT intervals prolonged by LV pacing were obviously shortened only after 2 weeks as ventricular systolic function recovered. Then even continuous LV alone pacing induced no TdP. These findings indicate novel electrical effects of cardiac resynchronization therapy.

  2. Successful pacing using a batteryless sunlight-powered pacemaker.

    Science.gov (United States)

    Haeberlin, Andreas; Zurbuchen, Adrian; Schaerer, Jakob; Wagner, Joerg; Walpen, Sébastien; Huber, Christoph; Haeberlin, Heinrich; Fuhrer, Juerg; Vogel, Rolf

    2014-10-01

    Today's cardiac pacemakers are powered by batteries with limited energy capacity. As the battery's lifetime ends, the pacemaker needs to be replaced. This surgical re-intervention is costly and bears the risk of complications. Thus, a pacemaker without primary batteries is desirable. The goal of this study was to test whether transcutaneous solar light could power a pacemaker. We used a three-step approach to investigate the feasibility of sunlight-powered cardiac pacing. First, the harvestable power was estimated. Theoretically, a subcutaneously implanted 1 cm(2) solar module may harvest ∼2500 µW from sunlight (3 mm implantation depth). Secondly, ex vivo measurements were performed with solar cells placed under pig skin flaps exposed to a solar simulator and real sunlight. Ex vivo measurements under real sunlight resulted in a median output power of 4941 µW/cm(2) [interquartile range (IQR) 3767-5598 µW/cm(2), median skin flap thickness 3.0 mm (IQR 2.7-3.3 mm)]. The output power strongly depended on implantation depth (ρSpearman = -0.86, P pacemaker powered by a 3.24 cm(2) solar module was implanted in vivo in a pig to measure output power and to pace. In vivo measurements showed a median output power of >3500 µW/cm(2) (skin flap thickness 2.8-3.84 mm). Successful batteryless VVI pacing using a subcutaneously implanted solar module was performed. Based on our results, we estimate that a few minutes of direct sunlight (irradiating an implanted solar module) allow powering a pacemaker for 24 h using a suitable energy storage. Thus, powering a pacemaker by sunlight is feasible and may be an alternative energy supply for tomorrow's pacemakers. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  3. Biventricular / Left Ventricular Pacing in Hypertrophic Obstructive Cardiomyopathy: An Overview

    Directory of Open Access Journals (Sweden)

    Radu Vatasescu, MD

    2012-05-01

    Full Text Available Hypertrophic cardiomyopathy (HCM is an autosomal dominant inherited genetic disease characterized by compensatory pathological left ventricle (LV hypertrophy due to sarcomere dysfunction. In an important proportion of patients with HCM, the site and extent of cardiac hypertrophy results in severe obstruction to LV outflow tract (LVOT, contributing to disabling symptoms and increasing the risk of sudden cardiac death (SCD. In patients with progressive and/or refractory symptoms despite optimal pharmacological treatment, invasive therapies that diminish or abolish LVOT obstruction relieve heart failure-related symptoms, improve quality of life and could be associated with long-term survival similar to that observed in the general population. The gold standard in this respect is surgical septal myectomy, which might be supplementary associated with a reduction in SCD. Percutaneous techniques, particularly alcohol septal ablation (ASA and more recently radiofrequency (RF septal ablation, can achieve LVOT gradient reduction and symptomatic benefit in a large proportion of HOCM patients at the cost of a supposedly limited septal myocardial necrosis and a 10-20% risk of chronic atrioventricular block. After an initial period of enthusiasm, standard DDD pacing failed to show in randomized trials significant LVOT gradient reductions and objective improvement in exercise capacity. However, case reports and recent small pilot studies suggested that atrial synchronous LV or biventricular (biV pacing significantly reduce LVOT obstruction and improve symptoms (acutely as well as long-term in a large proportion of severely symptomatic HOCM patients not suitable to other gradient reduction therapies. Moreover, biV/LV pacing in HOCM seems to be associated with significant LV reverse remodelling.

  4. Does reducing unnecessary right ventricular pacing improve sympathetic activity and innervation of heart in sinus node disease patients? MVP and SafeR study.

    Science.gov (United States)

    Miyamoto, Mihoko; Kimura, Yuichiro; Hosoda, Junya; Matsumoto, Katsumi; Matsushita, Kohei; Ishikawa, Toshiyuki; Umemura, Satoshi

    2012-01-01

    Ventricular desynchronization imposed by ventricular pacing causes regional disturbances of adrenergic innervation in the left ventricular myocardium and increases the risk of heart failure and atrial fibrillation (AF) in patients with sinus node disease (SND). As a result, decreased iodine-123 metaiodobenzylguanidine (I-(123 )MIBG) uptake occurs in patients with an implanted permanent pacemaker. Fourteen SND patients with an implanted pacemaker equipped with an algorithm for reducing unnecessary right ventricular pacing (RURVP) were enrolled. Pacemakers were programmed to RURVP mode for the first 12 weeks, and then reprogrammed to DDD for the last 12 weeks. At the end of each mode, data on cumulative percent ventricular pacing (%Vp), atrial high rate episodes (%AHR), I-(123 )MIBG myocardial scintigraphy, brain natriuretic peptide (BNP), human atrial natriuretic peptide (hANP), and myocardial damage indices typified by troponin T and C-reactive protein (CRP) were collected. %Vp was lower in RURVP than in DDD (0.2% versus 95.7%, P = 0.00098). BNP, hANP, troponin T, and CRP did not differ significantly between the pacing modes. However, I-(123 )MIBG findings of patients with full ventricular pacing in DDD improved in RURVP. In contrast, among patients without full ventricular pacing in DDD, their I-(123 )MIBG findings did not differ significantly between the pacing modes. In SND patients with normal cardiac function and intact atrioventricular conduction, the reduction of %Vp in RURVP was due to the reduction of ineffective pacing and fusion pacing in DDD. Therefore, these 2 types of pacing do not affect cardiac pump function.

  5. Model-based imaging of cardiac electrical function in human atria

    Science.gov (United States)

    Modre, Robert; Tilg, Bernhard; Fischer, Gerald; Hanser, Friedrich; Messnarz, Bernd; Schocke, Michael F. H.; Kremser, Christian; Hintringer, Florian; Roithinger, Franz

    2003-05-01

    Noninvasive imaging of electrical function in the human atria is attained by the combination of data from electrocardiographic (ECG) mapping and magnetic resonance imaging (MRI). An anatomical computer model of the individual patient is the basis for our computer-aided diagnosis of cardiac arrhythmias. Three patients suffering from Wolff-Parkinson-White syndrome, from paroxymal atrial fibrillation, and from atrial flutter underwent an electrophysiological study. After successful treatment of the cardiac arrhythmia with invasive catheter technique, pacing protocols with stimuli at several anatomical sites (coronary sinus, left and right pulmonary vein, posterior site of the right atrium, right atrial appendage) were performed. Reconstructed activation time (AT) maps were validated with catheter-based electroanatomical data, with invasively determined pacing sites, and with pacing at anatomical markers. The individual complex anatomical model of the atria of each patient in combination with a high-quality mesh optimization enables accurate AT imaging, resulting in a localization error for the estimated pacing sites within 1 cm. Our findings may have implications for imaging of atrial activity in patients with focal arrhythmias.

  6. Posibilities of cardiac pacemaker use in paroxsysmal atrial fibrilation

    Directory of Open Access Journals (Sweden)

    Borut Kamenik

    2005-12-01

    Full Text Available Background: Prevention of atrial fibrillation is a big therapeutic challenge because of all known negative consequences of this the most frequent cardiac arrhythmia. Numerous of clinical studies showed bad control or ineffectiveness of antiarhythmic drugs. Nonfarmakological therapies like surgical treatment, radiofrequency ablation and atrial pacing are being tested. Effectiveness of atrial pacing in prevention of paroxysmal artial fibrillation has been documented in numerous prospective studies and is effective for a long time interval, but only for patients with bradicardic underlying cardiac rhythm. In Normocardic rhythm or normal AV conduction the effective Atrial fibrillation prevention was not proven. The mechanism of action is based on premature atrial complex suppression, reduction of dispersion of refractoriness after short-long cycles and reduction of interatrial conduction delay. The atrial stimulation site or multi-site atrial pacing could be effective in AF prevention when interatrial conduction delay is present; otherwise the difference is not significant.Conclusions: In bradicardic patient who has frequent paroxysms of atrial fibrillation, regardless if bradycardia is due to ineffective antiarrhythmic drug treathement, implantation of DDDR pacemaker with atrial prevention algorhythm is indicated. If the P-wave duration is >120 milliseconds multi-site atrial pacing or septal atrial pacing should be considered. Pacemaker diagnostic tools could be used for adequate start of anticoagulant therapy and control of effectiveness of anthyarhythmic drug therapy.

  7. Synchronous intra-myocardial ventricular pacing without crossing the tricuspid valve or entering the coronary sinus

    Energy Technology Data Exchange (ETDEWEB)

    Konecny, Tomas; DeSimone, Christopher V.; Friedman, Paul A.; Bruce, Charles [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Asirvatham, Samuel J., E-mail: asirvatham.samuel@mayo.edu [Department of Medicine, Cardiovascular Diseases, Mayo Clinic, Rochester, MN (United States); Department of Pediatric and Adolescent Medicine, Pediatric Cardiology, Mayo Clinic, Rochester, MN (United States)

    2013-05-15

    Ventricular pacing is most commonly performed at the right ventricular (RV) apex. This is not without risk as placement requires crossing the tricuspid valve (TV) and may cause valvular dysfunction and dyssynchronous activation of the ventricles. The fact that the tricuspid valve lies more apically than the mitral valve allows for the possibility of pacing the ventricles from the right atrium (RA) via the “atrio-ventricular septum” without crossing the TV or entering the coronary sinus (CS). In order to mitigate far field activation inherent to current pacing technology, we constructed a novel lead in which the cathode and anode are both intra-myocardial. We demonstrate safety and efficacy of this novel lead for ventricular pacing at the atrio-ventricular septum in canines, including improved synchronous activation of both ventricles, improved differentiation in ventricular versus atrial sensing, while providing reliable ventricular capture, opening novel and a potentially safer alternative to human cardiac resynchronization therapy.

  8. Altering Pace Control and Pace Regulation: Attentional Focus Effects during Running.

    Science.gov (United States)

    Brick, Noel E; Campbell, Mark J; Metcalfe, Richard S; Mair, Jacqueline L; Macintyre, Tadhg E

    2016-05-01

    To date, there are no published studies directly comparing self-controlled (SC) and externally controlled (EC) pace endurance tasks. However, previous research suggests pace control may impact on cognitive strategy use and effort perceptions. The primary aim of this study was to investigate the effects of manipulating perception of pace control on attentional focus, physiological, and psychological outcomes during running. The secondary aim was to determine the reproducibility of self-paced running performance when regulated by effort perceptions. Twenty experienced endurance runners completed four 3-km time trials on a treadmill. Subjects completed two SC pace trials, one perceived exertion clamped (PE) trial, and one EC pace time trial. PE and EC were completed in a counterbalanced order. Pacing strategy for EC and perceived exertion instructions for PE replicated the subjects' fastest SC time trial. Subjects reported a greater focus on cognitive strategies such as relaxing and optimizing running action during EC than during SC. The mean HR was 2% lower during EC than that during SC despite an identical pacing strategy. Perceived exertion did not differ between the three conditions. However, increased internal sensory monitoring coincided with elevated effort perceptions in some subjects during EC and a 10% slower completion time for PE (13.0 ± 1.6 min) than that for SC (11.8 ± 1.2 min). Altering pace control and pace regulation impacted on attentional focus. External control over pacing may facilitate performance, particularly when runners engage attentional strategies conducive to improved running efficiency. However, regulating pace based on effort perceptions alone may result in excessive monitoring of bodily sensations and a slower running speed. Accordingly, attentional focus interventions may prove beneficial for some athletes to adopt task-appropriate attentional strategies to optimize performance.

  9. Presentation Time Concerning System-Paced Multimedia Instructions and the Superiority of Learner Pacing

    Science.gov (United States)

    Stiller, Klaus D.; Petzold, Kirstin; Zinnbauer, Peter

    2011-01-01

    The superiority of learner-paced over system-paced instructions was demonstrated in multiple experiments. In these experiments, the system-paced presentations were highly speeded, causing cognitive overload, while the learner-paced instructions allowed adjustments of the presentational flow to the learner's needs by pacing facilities, mostly…

  10. Ischemic Stroke Due to Cardiac Involvement: Emery Dreifuss Patient

    Directory of Open Access Journals (Sweden)

    Ersin Kasım Ulusoy

    2015-08-01

    Full Text Available Emery-Dreifuss muscular dystrophy (EDMD is a hereditary disease. It is characterized by early-onset contractures, slowly progressive weakness, fatigue related to skapulo-humero-peroneal muscle weakness, cardiomyopathy which develops in adulthood and cardiac conduction system block. Cardiac involvement has a prognostic significance in patients with EDMD and even sudden cardiac death may be the first clinical presentation. In this article, an EDMD patient with ischemic stroke clinic who didn’t have regular cardiac follow-up was reported and the importance of the treatment of cardiac diseases which could play a role in ischemic stroke etiology and the implantation of pace-maker was mentioned.

  11. Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heart.

    Science.gov (United States)

    Han, Chengzong; Pogwizd, Steven M; Killingsworth, Cheryl R; He, Bin

    2012-01-01

    Single-beat imaging of myocardial activation promises to aid in both cardiovascular research and clinical medicine. In the present study we validate a three-dimensional (3D) cardiac electrical imaging (3DCEI) technique with the aid of simultaneous 3D intracardiac mapping to assess its capability to localize endocardial and epicardial initiation sites and image global activation sequences during pacing and ventricular tachycardia (VT) in the canine heart. Body surface potentials were measured simultaneously with bipolar electrical recordings in a closed-chest condition in healthy canines. Computed tomography images were obtained after the mapping study to construct realistic geometry models. Data analysis was performed on paced rhythms and VTs induced by norepinephrine (NE). The noninvasively reconstructed activation sequence was in good agreement with the simultaneous measurements from 3D cardiac mapping with a correlation coefficient of 0.74 ± 0.06, a relative error of 0.29 ± 0.05, and a root mean square error of 9 ± 3 ms averaged over 460 paced beats and 96 ectopic beats including premature ventricular complexes, couplets, and nonsustained monomorphic VTs and polymorphic VTs. Endocardial and epicardial origins of paced beats were successfully predicted in 72% and 86% of cases, respectively, during left ventricular pacing. The NE-induced ectopic beats initiated in the subendocardium by a focal mechanism. Sites of initial activation were estimated to be ∼7 mm from the measured initiation sites for both the paced beats and ectopic beats. For the polymorphic VTs, beat-to-beat dynamic shifts of initiation site and activation pattern were characterized by the reconstruction. The present results suggest that 3DCEI can noninvasively image the 3D activation sequence and localize the origin of activation of paced beats and NE-induced VTs in the canine heart with good accuracy. This 3DCEI technique offers the potential to aid interventional therapeutic procedures for

  12. Leadless cardiac pacemakers: present and the future.

    Science.gov (United States)

    Chew, Derek S; Kuriachan, Vikas

    2018-01-01

    Pacing technology for many decades has been composed of a generator attached to leads that are usually transvenous. Recently, leadless pacemakers have been studied in clinical settings and now available for use in many countries. This includes the single-component Nanostim Leadless Cardiac Pacemaker and Micra Transcatheter Pacing System, as well as the multicomponent Wireless Stimulation Endocardial system. Clinical studies in single-component leadless pacing technology has shown that they can be successfully implanted with minimal complications. The follow-up studies also seem to confirm the findings from the initial clinical trials. These systems offer some advantages over a traditional pacing system comprised of a subcutaneous generator and transvenous leads. In many ways, these leadless systems are disruptive technologies that are changing the traditional pacemaker concept and preferred for some patients. Ongoing research is needed to better assess their long-term function, safety, and end-of-life strategies. In the future, multichamber leadless pacing is expected to be developed and perhaps obviating the need for transvenous leads and their associated complications.

  13. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads.

    Science.gov (United States)

    Candinas, R; Duru, F; Schneider, J; Lüscher, T F; Stokes, K

    1999-02-01

    To analyze the site and thickness of encapsulation around ventricular endocardial pacing leads and the extent of tricuspid valve adhesion, from today's perspective, with implications for lead removal and sensor location. Gross cardiac postmortem analysis was performed in 11 cases (8 female and 3 male patients; mean age, 78+/-7 years). None of the patients had died because of pacemaker malfunction. The mean implant time was 61+/-60 months (range, 4 to 184). The observations ranged from encapsulation only at the tip of the pacing lead to complete encapsulation along the entire length of the pacing lead within the right ventricle. Substantial areas of adhesion at the tricuspid valve apparatus were noted in 7 of the 11 cases (64%). The firmly attached leads could be removed only by dissection, and in some cases, removal was possible only by damaging the associated structures. No specific optimal site for sensor placement could be identified along the ventricular portion of the pacing leads; however, the fibrotic response was relatively less prominent in the atrial chamber. Extensive encapsulation is present in most long-term pacemaker leads, which may complicate lead removal. The site and thickness of encapsulation seem to be highly variable. Tricuspid valve adhesion, which is usually underestimated, may be severe. In contrast to earlier reports, our study demonstrates that the extent of fibrotic encapsulation may not be related to the duration since lead implantation. Moreover, we noted no ideal encapsulation-free site for sensors on the ventricular portion of long-term pacing leads.

  14. Dynamic cardiomyoplasty using artificial muscle.

    Science.gov (United States)

    Suzuki, Yasuyuki; Daitoku, Kazuyuki; Minakawa, Masahito; Fukui, Kozo; Fukuda, Ikuo

    2008-01-01

    Dynamic cardiomyoplasty using latissimus dorsi muscle was previously used to compensate for congestive heart failure. Now, however, this method is not acceptable because the long-term result was not as expected owing to fatigue of the skeletal muscle. BioMetal fiber developed by Toki Corporation is one of the artificial muscles activated by electric current. The behavior of this fiber is similar to that of organic muscle. We made an artificial muscle like the latissimus dorsi using BioMetal fiber and tested whether we could use this new muscle as a cardiac supporting device. Testing one Biometal fiber showed the following performance: practical use maximal generative force was 30 g, exercise variation was 50%, and the standard driving current was 220 mA. We created a 4 x 12-cm tabular artificial muscle using 8 BioMetal fibers as a cardiac support device. We also made a simulation circuit composed of a 6 x 8-cm soft bag with unidirectional valves, reservoir, and connecting tube. The simulation circuit was filled with water and the soft bag was wrapped with the artificial muscle device. After powering the device electrically at 9 V with a current of 220 mA for each fiber, we measured the inside pressure and observed the movement of the artificial device. The artificial muscle contracted in 0.5 s for peak time and squeezed the soft bag. The peak pressure inside the soft bag was measured as 10 mmHg. Although further work will be needed to enhance the speed of deformability and movement simulating contraction, we conclude that artificial muscle may be potentially useful as a cardiac assistance device that can be developed for dynamic cardiomyoplasty.

  15. Breath pacing system and method for pacing the respiratory activity of a subject

    NARCIS (Netherlands)

    2016-01-01

    To provide a breath pacing system and a corresponding method for pacing the respiratory activity of a subject that provide the possibility to adapt the output signal to the respiration characteristics of the subject automatically and effectively a breath pacing system (10) for pacing the respiratory

  16. The effect of right ventricular pacing on myocardial oxidative metabolism and efficiency: relation with left ventricular dyssynchrony

    Energy Technology Data Exchange (ETDEWEB)

    Ukkonen, Heikki; Saraste, Antti; Koistinen, Juhani [Turku University Hospital, Department of Medicine, P.O. Box 52, Turku (Finland); Tops, Laurens; Bax, Jeroen [Leiden University Medical Center, Leiden (Netherlands); Naum, Alexander [University of Turku, Turku PET Centre, Turku (Finland); Knuuti, Juhani [University of Turku, Turku PET Centre, Turku (Finland); Turku University Hospital, Turku PET Centre, P.O. Box 52, Turku (Finland)

    2009-12-15

    Right ventricular (RV) apical pacing induces dyssynchrony by a left bundle branch block type electrical activation sequence in the heart and may impair left ventricular (LV) function. Whether these functional changes are accompanied by changes in myocardial perfusion, oxidative metabolism and efficiency, and the relation with the induction of LV dyssynchrony are unknown. Our study was designed to investigate the acute effects of RV pacing on these parameters. Ten patients with normal LV ejection fraction and VVI/DDD pacemaker were studied during AAI pacing/sinus rhythm without RV pacing (pacing-OFF) and with RV pacing (pacing-ON) at the same heart rate. Dynamic [{sup 15}O]water and [{sup 11}C]acetate positron emission tomography was used to measure perfusion and oxidative metabolism (k{sub mono}) of the LV. An echocardiographic examination was used to assess LV stroke volume (SV) and LV dyssynchrony. Myocardial efficiency of forward work was calculated as systolic blood pressure x cardiac output/LV mass/k{sub mono}. RV pacing decreased SV in all subjects (mean decrease 13%, from 76 {+-} 7 to 66 {+-} 7 ml, p = 0.004), but global perfusion and k{sub mono} were unchanged. The efficiency tended to be lower with pacing-ON (70 {+-} 20 vs 81 {+-} 21 mmHg l/g, p = 0.066). In patients with dyssynchrony during pacing (n = 6) efficiency decreased by 23% (from 78 {+-} 25 to 60 {+-} 14 mmHg l/g, p = 0.02), but in patients without dyssynchrony no change in efficiency was detected. Accordingly, heterogeneity in myocardial perfusion and oxidative metabolism was detected during pacing in patients with dyssynchrony but not in those without dyssynchrony. RV pacing resulted in a significant decrease in SV. However, deleterious effects on LV oxidative metabolism and efficiency were observed only in patients with dyssynchrony during RV pacing. (orig.)

  17. [Total artificial heart].

    Science.gov (United States)

    Antretter, H; Dumfarth, J; Höfer, D

    2015-09-01

    To date the CardioWest™ total artificial heart is the only clinically available implantable biventricular mechanical replacement for irreversible cardiac failure. This article presents the indications, contraindications, implantation procedere and postoperative treatment. In addition to a overview of the applications of the total artificial heart this article gives a brief presentation of the two patients treated in our department with the CardioWest™. The clinical course, postoperative rehabilitation, device-related complications and control mechanisms are presented. The total artificial heart is a reliable implant for treating critically ill patients with irreversible cardiogenic shock. A bridge to transplantation is feasible with excellent results.

  18. [Artificial organs].

    Science.gov (United States)

    Raguin, Thibaut; Dupret-Bories, Agnès; Debry, Christian

    2017-01-01

    Research has been fighting against organ failure and shortage of donations by supplying artificial organs for many years. With the raise of new technologies, tissue engineering and regenerative medicine, many organs can benefit of an artificial equivalent: thanks to retinal implants some blind people can visualize stimuli, an artificial heart can be proposed in case of cardiac failure while awaiting for a heart transplant, artificial larynx enables laryngectomy patients to an almost normal life, while the diabetic can get a glycemic self-regulation controlled by smartphones with an artificial device. Dialysis devices become portable, as well as the oxygenation systems for terminal respiratory failure. Bright prospects are being explored or might emerge in a near future. However, the retrospective assessment of putative side effects is not yet sufficient. Finally, the cost of these new devices is significant even if the advent of three dimensional printers may reduce it. © 2017 médecine/sciences – Inserm.

  19. Physiologic stress interventions in cardiac imaging

    International Nuclear Information System (INIS)

    Buda, A.J.

    1985-01-01

    Physiologic stress interventions are designed to assess the reserve capability of coronary flow and myocardial function. In the normal individual, a sufficiently intense physiologic stress may increase coronary flow and cardiac output by 500% to 600%. However, in patients with cardiac disease, these reserve responses may be absent, or considerably blunted. Thus, physiologic stress testing has proved extremely helpful in detecting cardiac abnormalities when resting cardiac function appears normal. Although dynamic exercise remains the standard approach to physiologic stress testing, a number of other interventions have been used, including: (1) isometric exercise, (2) atrial pacing, (3) cold pressor testing, (4) postextrasystolic potentiation, (5) volume loading, and (6) negative intrathoracic pressure. Each of these may be considered an alternative physiologic intervention whenever dynamic exercise is not feasible. These alternative approaches are important since, in our experience, 20% to 30% of subjects are unable to perform dynamic exercise, or exercise inadequately to produce a sufficiently intense cardiac stress. This chapter reviews physiologic considerations, indications, contraindications, protocols, and results of these physiologic stress interventions when used in combination with cardiac radionuclide procedures

  20. Multigated radionuclide study of the total artificial heart

    International Nuclear Information System (INIS)

    Datz, F.L.; Christian, P.E.; Taylor, A. Jr.; Hastings, W.L.; De Vries, W.C.

    1987-01-01

    A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent. (orig.)

  1. Multigated radionuclide study of the total artificial heart

    Energy Technology Data Exchange (ETDEWEB)

    Datz, F L; Christian, P E; Taylor, A Jr; Hastings, W L; De Vries, W C

    1987-07-01

    A permanent total artificial heart, the Jarvik-7, was implanted into a 61-year-old male with a severe cardiomyopathy. Gated radionuclide studies were performed in the patient both prior to surgery and following implantation. Preoperative gated radionuclide cardiac studies revealed marked left ventricular enlargement, severe hypokinesis and a left ventricular ejection fraction of 10%. The right ventricle was moderately enlarged with a 27% ejection fraction. Following implantation of the Jarvik-7 artificial heart, gated cardiac studies were performed with a computer gated by a signal from the heart controller. The left ventricular ejection fraction was 69% and the right ventricular ejection fraction was 62%. This compared to a theoretical ejection fraction of 74% for each ventricle based on chamber anatomy. There was excellent ventricular emptying. Phase analysis showed uniform diaphragm motion. The use of gated cardiac studies in humans may prove helpful in evaluating mechanical problems with the artificial heart, such as manlfunction of the diaphragm, before they become clinically apparent.

  2. A Case of a Cardiac Resynchronization Therapy-Defibrillator Exhibiting a Lower and Alternately Variable Basic Rate.

    Science.gov (United States)

    Iwazaki, Keigo; Kojima, Toshiya; Murasawa, Takahide; Yokota, Jun; Tanimoto, Hikaru; Matsuda, Jun; Fukuma, Nobuaki; Matsubara, Takumi; Shimizu, Yu; Oguri, Gaku; Hasumi, Eriko; Kubo, Hitoshi; Chang, Kyungho; Fujiu, Katsuhito; Komuro, Issei

    2018-04-06

    A cardiac resynchronization therapy defibrillator (CRT-D) (Medtronic Inc. Protecta XT) was implanted in a 67-year-old man who had cardiac sarcoidosis with extremely low cardiac function. He had ventricular tachycardia which was controlled by catheter ablation, medication and pacing. The programmed mode was DDI, lower rate was 90 beats/minute, paced AV delay was 150 ms, and the noncompetitive atrial pacing (NCAP) function was programmed as 300 ms.After his admission for pneumonia and heart failure, we changed his DDI mode to a DDD mode because he had atrial tachycardia, which led to inadequate bi-ventricular pacing. After a while, there were cycle lengths which were longer than his device setting and alternately varied. We were able to avoid this phenomenon with AV delay of 120 ms and NCAP of 200 ms.NCAP is an algorithm which creates a gap above a certain period after the detection of an atrial signal during the postventricular atrial refractory period of the pacemaker. This is to prevent atrial tachycardia and repetitive non-reentrant ventriculoatrial (VA) synchrony in the presence of retrograde VA conduction. But in this case, NCAP algorithm induced much lower rate than the programmed basic lower rate. This situation produced some arrhythmias and exacerbated symptoms of heart failure. This had to be paid attention to, especially when the device was programmed at high basic heart rate.

  3. Estimation of 3-D conduction velocity vector fields from cardiac mapping data.

    Science.gov (United States)

    Barnette, A R; Bayly, P V; Zhang, S; Walcott, G P; Ideker, R E; Smith, W M

    2000-08-01

    A method to estimate three-dimensional (3-D) conduction velocity vector fields in cardiac tissue is presented. The speed and direction of propagation are found from polynomial "surfaces" fitted to space-time (x, y, z, t) coordinates of cardiac activity. The technique is applied to sinus rhythm and paced rhythm mapped with plunge needles at 396-466 sites in the canine myocardium. The method was validated on simulated 3-D plane and spherical waves. For simulated data, conduction velocities were estimated with an accuracy of 1%-2%. In experimental data, estimates of conduction speeds during paced rhythm were slower than those found during normal sinus rhythm. Vector directions were also found to differ between different types of beats. The technique was able to distinguish between premature ventricular contractions and sinus beats and between sinus and paced beats. The proposed approach to computing velocity vector fields provides an automated, physiological, and quantitative description of local electrical activity in 3-D tissue. This method may provide insight into abnormal conduction associated with fatal ventricular arrhythmias.

  4. Pacing stress echocardiography

    Directory of Open Access Journals (Sweden)

    Agrusta Marco

    2005-12-01

    Full Text Available Abstract Background High-rate pacing is a valid stress test to be used in conjunction with echocardiography; it is independent of physical exercise and does not require drug administration. There are two main applications of pacing stress in the echo lab: the noninvasive detection of coronary artery disease through induction of a regional transient dysfunction; and the assessment of contractile reserve through peak systolic pressure/ end-systolic volume relationship at increasing heart rates to assess global left ventricular contractility. Methods The pathophysiologic rationale of pacing stress for noninvasive detection of coronary artery disease is obvious, with the stress determined by a controlled increase in heart rate, which is a major determinant of myocardial oxygen demand, and thereby tachycardia may exceed a fixed coronary flow reserve in the presence of hemodynamically significant coronary artery disease. The use of pacing stress echo to assess left ventricular contractile reserve is less established, but promising. Positive inotropic interventions are mirrored by smaller end-systolic volumes and higher end-systolic pressures. An increased heart rate progressively increases the force of ventricular contraction (Bowditch treppe or staircase phenomenon. To build the force-frequency relationship, the force is determined at different heart rate steps as the ratio of the systolic pressure (cuff sphygmomanometer/end-systolic volume index (biplane Simpson rule. The heart rate is determined from ECG. Conclusion Two-dimensional echocardiography during pacing is a useful tool in the detection of coronary artery disease. Because of its safety and ease of repeatability noninvasive pacing stress echo can be the first-line stress test in patients with permanent pacemaker. The force-frequency can be defined as up- sloping (normal when the peak stress pacing systolic pressure/end-systolic volume index is higher than baseline and intermediate stress

  5. Living cardiac patch: the elixir for cardiac regeneration.

    Science.gov (United States)

    Lakshmanan, Rajesh; Krishnan, Uma Maheswari; Sethuraman, Swaminathan

    2012-12-01

    A thorough understanding of the cellular and muscle fiber orientation in left ventricular cardiac tissue is of paramount importance for the generation of artificial cardiac patches to treat the ischemic myocardium. The major challenge faced during cardiac patch engineering is to choose a perfect combination of three entities; cells, scaffolds and signaling molecules comprising the tissue engineering triad for repair and regeneration. This review provides an overview of various scaffold materials, their mechanical properties and fabrication methods utilized in cardiac patch engineering. Stem cell therapies in clinical trials and the commercially available cardiac patch materials were summarized in an attempt to provide a recent perspective in the treatment of heart failure. Various tissue engineering strategies employed thus far to construct viable thick cardiac patches is schematically illustrated. Though many strategies have been proposed for fabrication of various cardiac scaffold materials, the stage and severity of the disease condition demands the incorporation of additional cues in a suitable scaffold material. The scaffold may be nanofibrous patch, hydrogel or custom designed films. Integration of stem cells and biomolecular cues along with the scaffold may provide the right microenvironment for the repair of unhealthy left ventricular tissue as well as promote its regeneration.

  6. PACE Status Update

    Energy Technology Data Exchange (ETDEWEB)

    M., Zimring,; Hoffman, I.; Fuller, M.

    2010-08-11

    The Federal Housing Finance Agency (FHFA) regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On July 6, 2010, FHFA and the Office of the Comptroller of the Currency (OCC) concluded that Property Assessed Clean Energy (PACE) programs 'present significant safety and soundness concerns' to the housing finance industry. This statement came after a year of discussions with state and federal agencies in which PACE, a novel mechanism for financing energy efficiency and renewable energy improvements, has gone from receiving support from the White House, canonization as one of Scientific American's 'World Changing Ideas' and legislative adoption in 24 states to questionable relevance, at least in the residential sector. Whether PACE resumes its expansion as an innovative tool for financing energy efficiency and clean generation depends on outcomes in each of the three branches of government - discussions on a PACE pilot phase among federal agencies, litigation in federal court, and legislation in Congress - all highly uncertain. This policy brief addresses the practical impacts of these possible outcomes on existing and emerging PACE programs across the United States and potential paths forward.

  7. RIght VErsus Left Apical transvenous pacing for bradycardia: Results of the RIVELA randomized study

    Directory of Open Access Journals (Sweden)

    Haran Burri

    2017-11-01

    Full Text Available Aims: To compare cardiac function when pacing from the right or left ventricular apex in patients with preserved left ventricular systolic function, at 1-year follow-up. Methods: Prospective, multicentre centre randomizing conventional right ventricular apical (RVA versus left ventricular apical (LVA pacing using a coronary sinus lead in patients requiring ventricular pacing for bradycardia. Follow-up was performed using 3D-echocardiography at 6 and 12 months. Results: A total of 36 patients (age 75.4 ± 8.7 years, 21 males were enrolled (17 patients in the RVA group and 19 patients in the LVA group. A right ventricular lead was implanted in 8 patients in the LVA group, mainly because of high capture thresholds. There were no differences in the primary endpoint of LVEF at 1 year (60.4 ± 7.1% vs 62.1 ± 7.2% for the RVA and LVA groups respectively, P = 0.26 nor in any of the secondary endpoints (left ventricular dimensions, left ventricular diastolic function, right ventricular systolic function and tricuspid/mitral insufficiency. LVEF did not change significantly over follow-up in either group. Capture thresholds were significantly higher in the LVA group, and two patients had unexpected loss of capture of the coronary sinus lead during follow-up. Conclusions: Left univentricular pacing seems to be comparable to conventional RVA pacing in terms of ventricular function at up to 1 year follow-up, and is an option to consider in selected patients (e.g. those with a tricuspid valve prosthesis. Keywords: Ventricular pacing, Right ventricle, Left ventricle, Coronary sinus, Ventricular function

  8. Increases in myocardial workload induced by rapid atrial pacing trigger alterations in global metabolism.

    Directory of Open Access Journals (Sweden)

    Aslan T Turer

    Full Text Available To determine whether increases in cardiac work lead to alterations in the plasma metabolome and whether such changes arise from the heart or peripheral organs.There is growing evidence that the heart influences systemic metabolism through endocrine effects and affecting pathways involved in energy homeostasis.Nineteen patients referred for cardiac catheterization were enrolled. Peripheral and selective coronary sinus (CS blood sampling was performed at serial timepoints following the initiation of pacing, and metabolite profiling was performed by liquid chromatography-mass spectrometry (LC-MS.Pacing-stress resulted in a 225% increase in the median rate·pressure product from baseline. Increased myocardial work induced significant changes in the peripheral concentration of 43 of 125 metabolites assayed, including large changes in purine [adenosine (+99%, p = 0.006, ADP (+42%, p = 0.01, AMP (+79%, p = 0.004, GDP (+69%, p = 0.003, GMP (+58%, p = 0.01, IMP (+50%, p = 0.03, xanthine (+61%, p = 0.0006], and several bile acid metabolites. The CS changes in metabolites qualitatively mirrored those in the peripheral blood in both timing and magnitude, suggesting the heart was not the major source of the metabolite release.Isolated increases in myocardial work can induce changes in the plasma metabolome, but these changes do not appear to be directly cardiac in origin. A number of these dynamic metabolites have known signaling functions. Our study provides additional evidence to a growing body of literature on metabolic 'cross-talk' between the heart and other organs.

  9. A slow-releasing form of prostacyclin agonist (ONO1301SR) enhances endogenous secretion of multiple cardiotherapeutic cytokines and improves cardiac function in a rapid-pacing-induced model of canine heart failure.

    Science.gov (United States)

    Shirasaka, Tomonori; Miyagawa, Shigeru; Fukushima, Satsuki; Saito, Atsuhiro; Shiozaki, Motoko; Kawaguchi, Naomasa; Matsuura, Nariaki; Nakatani, Satoshi; Sakai, Yoshiki; Daimon, Takashi; Okita, Yutaka; Sawa, Yoshiki

    2013-08-01

    Cardiac functional deterioration in dilated cardiomyopathy (DCM) is known to be reversed by intramyocardial up-regulation of multiple cardioprotective factors, whereas a prostacyclin analog, ONO1301, has been shown to paracrinally activate interstitial cells to release a variety of protective factors. We here hypothesized that intramyocardial delivery of a slow-releasing form of ONO1301 (ONO1301SR) might activate regional myocardium to up-regulate cardiotherapeutic factors, leading to regional and global functional recovery in DCM. ONO1301 elevated messenger RNA and protein level of hepatocyte growth factor, vascular endothelial growth factor, and stromal-derived factor-1 of normal human dermal fibroblasts in a dose-dependent manner in vitro. Intramyocardial delivery of ONO1301SR, which is ONO1301 mixed with polylactic and glycolic acid polymer (PLGA), but not that of PLGA only, yielded significant global functional recovery in a canine rapid pacing-induced DCM model, assessed by echocardiography and cardiac catheterization (n = 5 each). Importantly, speckle-tracking echocardiography unveiled significant regional functional recovery in the ONO1301-delivered territory, consistent to significantly increased vascular density, reduced interstitial collagen accumulation, attenuated myocyte hypertrophy, and reversed mitochondrial structure in the corresponding area. Intramyocardial delivery of ONO1301SR, which is a PLGA-coated slow-releasing form of ONO1301, up-regulated multiple cardiotherapeutic factors in the injected territory, leading to region-specific reverse left ventricular remodeling and consequently a global functional recovery in a rapid-pacing-induced canine DCM model, warranting a further preclinical study to optimize this novel drug-delivery system to treat DCM. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  10. Bachmann's Bundle Pacing not Only Improves Interatrial Conduction but Also Reduces the Need for Ventricular Pacing.

    Science.gov (United States)

    Sławuta, Agnieszka; Kliś, Magdalena; Skoczyński, Przemysław; Bańkowski, Tomasz; Moszczyńska-Stulin, Joanna; Gajek, Jacek

    2016-01-01

    Patients treated for sick sinus syndrome may have interatrial conduction disorder leading to atrial fibrillation. This study was aimed to assess the influence of the atrial pacing site on interatrial and atrioventricular conduction as well as the percentage of ventricular pacing in patients with sick sinus syndrome implanted with atrioventricular pacemaker. The study population: 96 patients (58 females, 38 males) aged 74.1 ± 11.8 years were divided in two groups: Group 1 (n = 44) with right atrial appendage pacing and group 2 (n = 52) with Bachmann's area pacing. We assessed the differences in atrioventricular conduction in sinus rhythm and atrial 60 and 90 bpm pacing, P-wave duration and percentage of ventricular pacing. No differences in baseline P-wave duration in sinus rhythm between the groups (102.4 ± 17 ms vs. 104.1 ± 26 ms, p = ns.) were noted. Atrial pacing 60 bpm resulted in longer P-wave in group 1 vs. group 2 (138.3 ± 21 vs. 106.1 ± 15 ms, p < 0.01). The differences between atrioventricular conduction time during sinus rhythm and atrial pacing at 60 and 90 bpm were significantly longer in patients with right atrial appendage vs. Bachmann's pacing (44.1 ± 17 vs. 9.2 ± 7 ms p < 0.01 and 69.2 ± 31 vs. 21.4 ± 12 ms p < 0.05, respectively). The percentage of ventricular pacing was higher in group 1 (21 vs. 4%, p < 0.01). Bachmann's bundle pacing decreases interatrial and atrioventricular conduction delay. Moreover, the frequency-dependent atrioventricular conduction lengthening is much less pronounced during Bachmann's bundle pacing. Right atrial appendage pacing in sick sinus syndrome patients promotes a higher percentage of ventricular pacing.

  11. Optimal algorithm switching for the estimation of systole period from cardiac microacceleration signals (SonR).

    Science.gov (United States)

    Giorgis, L; Frogerais, P; Amblard, A; Donal, E; Mabo, P; Senhadji, L; Hernández, A I

    2012-11-01

    Previous studies have shown that cardiac microacceleration signals, recorded either cutaneously, or embedded into the tip of an endocardial pacing lead, provide meaningful information to characterize the cardiac mechanical function. This information may be useful to personalize and optimize the cardiac resynchronization therapy, delivered by a biventricular pacemaker, for patients suffering from chronic heart failure (HF). This paper focuses on the improvement of a previously proposed method for the estimation of the systole period from a signal acquired with a cardiac microaccelerometer (SonR sensor, Sorin CRM SAS, France). We propose an optimal algorithm switching approach, to dynamically select the best configuration of the estimation method, as a function of different control variables, such as the signal-to-noise ratio or heart rate. This method was evaluated on a database containing recordings from 31 patients suffering from chronic HF and implanted with a biventricular pacemaker, for which various cardiac pacing configurations were tested. Ultrasound measurements of the systole period were used as a reference and the improved method was compared with the original estimator. A reduction of 11% on the absolute estimation error was obtained for the systole period with the proposed algorithm switching approach.

  12. Pharmacological treatment of cardiac glycoside poisoning

    OpenAIRE

    Roberts, Darren M.; Gallapatthy, Gamini; Dunuwille, Asunga; Chan, Betty S.

    2015-01-01

    Cardiac glycosides are an important cause of poisoning, reflecting their widespread clinical usage and presence in natural sources. Poisoning can manifest as varying degrees of toxicity. Predominant clinical features include gastrointestinal signs, bradycardia and heart block. Death occurs from ventricular fibrillation or tachycardia. A wide range of treatments have been used, the more common including activated charcoal, atropine, ??adrenoceptor agonists, temporary pacing, anti?digoxin Fab a...

  13. Atrial pacing and thallium 201 scintigraphy: combined use for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Stratmann, H.G.; Mark, A.L.; Walter, K.E.; Fletcher, J.W.; Williams, G.A.

    1987-01-01

    To evaluate the presence of coronary artery disease (CAD), atrial pacing and thallium 201 scintigraphy were performed in 36 patients with stable angina pectoris who were unable to perform an adequate exercise stress test. All patients underwent cardiac catheterization. Nine patients had previously undergone coronary artery bypass surgery. Significant CAD (one or more lesions greater than or equal to 50%) was present in 33 patients. Atrial pacing produced ischemic ST segment depression (greater than or equal to 1 mm) in 18 (55%) patients with CAD, and angina in 20 patients (61%). As the number of vessels with CAD increased, there was no significant change in the sensitivities of pacing-induced angina or ST segment depression for detecting CAD. In the 3 patients without CAD, ST segment depression occurred in 1 patient and angina in none. Thallium 201 scintigraphy demonstrated perfusion defects in 27 (82%) patients with CAD, with fixed defects seen in 13 studies (39%) and reversible defects in 15 (45%). In the 3 patients without CAD, no perfusion defects were seen. The thallium 201 scan successfully predicted the presence of CAD in patients with single-vessel disease but usually underestimated the number of vessels involved in patients with multivessel disease. Combined sensitivity of pacing-induced ST segment depression and an abnormal thallium 201 scan finding for detecting CAD was 91%. The authors conclude that combined atrial pacing and thallium 201 scintigraphy is a useful test for detecting CAD in patients unable to perform an adequate exercise stress test

  14. Solving fatigue-related problems with cardiac arrest survivors living in the community.

    Science.gov (United States)

    Kim, Young Joo; Rogers, Joan C; Raina, Ketki D; Callaway, Clifton W; Rittenberger, Jon C; Leibold, Mary Lou; Holm, Margo B

    2017-09-01

    The aim was to describe fatigue-related problems reported by post-cardiac arrest adults with chronic fatigue and energy conservation strategies generated using an Energy Conservation plus Problem Solving Therapy intervention. Following an introduction to the intervention process outlined in a Participant Workbook, participants engaged in the telephone intervention by identifying one to two fatigue-related problems. They then brainstormed with the interventionist to identify potential strategies to reduce fatigue, tested them, and either modified the strategies or moved to the next problem over three to five sessions. Eighteen cardiac arrest survivors with chronic fatigue identified instrumental activities of daily living and leisure activities as fatigue-related activities more frequently than basic activities of daily living. Energy Conservation strategies used most frequently were: plan ahead, pace yourself, delegate to others, and simplify the task. Post-cardiac arrest adults living in the community with chronic fatigue can return to previous daily activities by using energy conservation strategies such as planning ahead, pacing tasks, delegating tasks, and simplifying tasks. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions

    NARCIS (Netherlands)

    Barrère, F.; Mahmood, T.A.; de Groot, K.; van Blitterswijk, Clemens

    2008-01-01

    The past half century has seen explosive growth in the use of medical implants. Orthopedic, cardiac, oral, maxillofacial and plastic surgeons are examples of medical specialists treating millions of patients each year by implanting devices varying from pace makers, artificial hip joints, breast and

  16. Sudden Cardiac Death Risk Stratification Based on Phase Shift and XYt Graph Methods

    Czech Academy of Sciences Publication Activity Database

    Kára, T.; Jurák, Pavel; Novák, M.; Souček, M.; Nováková, Z.; Halámek, Josef; Šumbera, J.; Toman, J.; Štejfa, M.; Řiháček, I.

    1999-01-01

    Roč. 22, 6-Part II (1999), s. A20 ISSN 0147-8389. [CPES /11./ - Cardiac Pacing and Electrophysiology. 27.06.1999-30.06.1999, Berlin] Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

  17. Regional evidence of modulation of cardiac adiponectin level in dilated cardiomyopathy: pilot study in a porcine animal model

    Directory of Open Access Journals (Sweden)

    Caselli Chiara

    2012-11-01

    Full Text Available Abstract Background The role of systemic and myocardial adiponectin (ADN in dilated cardiomyopathy is still debated. We tested the regulation of both systemic and myocardial ADN and the relationship with AMP-activated protein kinase (AMPK activity in a swine model of non-ischemic dilated cardiomyopathy. Methods and results Cardiac tissue was collected from seven instrumented adult male minipigs by pacing the left ventricular (LV free wall (180 beats/min, 3 weeks, both from pacing (PS and opposite sites (OS, and from five controls. Circulating ADN levels were inversely related to global and regional cardiac function. Myocardial ADN in PS was down-regulated compared to control (p Conclusions Paradoxically, circulating ADN did not show any cardioprotective effect, confirming its role as negative prognostic biomarker of heart failure. Myocardial ADN was reduced in PS compared to control in an AMPK-independent fashion, suggesting the occurrence of novel mechanisms by which reduced cardiac ADN levels may regionally mediate the decline of cardiac function.

  18. Successful resuscitation of hypermagnesaemic asystolic cardiac arrest with the use of early transvenous cardiac pacemaker: a case report.

    Science.gov (United States)

    Miller, M A; Crystal, C S; Helphenstine, J; Young, S E

    2006-03-01

    A 63 year old woman presented to the emergency department (ED) with 1 week of progressive dyspnoea, constipation, and generalized weakness. She had undergone spinal fustion surgery 10 days previously, and had a history of chronic renal insufficiency. The patient had been using milk of magnesia and magnesium citrate in unknown amounts to alleviate her constipation over this time frame. During her ED stay she became progressively hypotensive and bradycardic, and despite aggressive resuscitative measures she suffered an asystolic arrest 1 hour into her ED course. She was resuscitated with conventional therapy, but her haemodynamic profile did not improve significantly until transvenous cardiac pacing was employed. Her magnesium level was 10.4 mmol/l. Treatment of magnesium overload has focused upon haemodialysis, forced diuresis, and the use of intravenous calcium salts. Case reports have previously documented survival of moderately to severely ill patients when these modalities have been used. Likewise, failure of resuscitation despite use of these methods has been previously noted. To our knowledge, this is the first reported case clearly demonstrating the efficacy of transvenous cardiac pacing to successfully resuscitate a patient upon whom multiple vasopressors, fluids, and calcium previously had no clear effect.

  19. Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents.

    Science.gov (United States)

    O'Donnell, David; Sperzel, Johannes; Thibault, Bernard; Rinaldi, Christopher A; Pappone, Carlo; Gutleben, Klaus-Jürgen; Leclercq, Christopher; Razavi, Hedi; Ryu, Kyungmoo; Mcspadden, Luke C; Fischer, Avi; Tomassoni, Gery

    2017-04-01

    The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  20. Echocardiography in patients with complications related to pacemakers and cardiac defibrillators.

    Science.gov (United States)

    Almomani, Ahmed; Siddiqui, Khadija; Ahmad, Masood

    2014-03-01

    The evolving indications and uses for implantable cardiac devices have led to a significant increase in the number of implanted devices each year. Implantation of endocardial leads for permanent pacemakers and cardiac defibrillators can cause many delayed complications. Complications may be mechanical and related to the interaction of the device leads with the valves and endomyocardium, e.g., perforation, infection, and thrombosis, or due to the electrical pacing of the myocardium and conduction abnormalities, e.g., left ventricular dyssynchrony. Tricuspid regurgitation, another delayed complication in these patients, may be secondary to both mechanical and pacing effects of the device leads. Echocardiography plays an important role in the diagnosis of these device-related complications. Both two-dimensional transthoracic echocardiography and transesophageal echocardiography provide useful diagnostic information. Real time three-dimensional echocardiography is a novel technique that can further enhance the detection of lead-related complications. © 2013, Wiley Periodicals, Inc.

  1. Heart rate variability alters cardiac repolarization and electromechanical dynamics.

    Science.gov (United States)

    Phadumdeo, Vrishti M; Weinberg, Seth H

    2018-04-07

    Heart rate continuously varies due to autonomic regulation, stochasticity in pacemaking, and circadian rhythm, collectively termed heart rate variability (HRV), during normal physiological conditions. Low HRV is clinically associated with an elevated risk of cardiac arrhythmias. Alternans, a beat-to-beat alternation in action potential duration (APD) and/or intracellular calcium (Ca) transient, is a well-known risk factor associated with cardiac arrhythmias that is typically studied under conditions of a constant pacing rate, i.e., the absence of HRV. In this study, we investigate the effects of HRV on the interplay between APD, Ca, and electromechanical properties, employing a nonlinear discrete-time map model that governs APD and intracellular Ca cycling with a stochastic pacing period. We find that HRV can decrease variation in APD and peak Ca at fast pacing rates for which alternans is present. Further, increased HRV typically disrupts the alternating pattern for both APD and peak Ca and weakens the correlation between APD and peak Ca, thus decoupling Ca-mediated instabilities from repolarization alternation. We find that the efficacy of these effects is regulated by the sarcoplasmic reticulum Ca uptake rate. Overall, these results demonstrate that HRV disrupts arrhythmogenic alternans and suggests that HRV may be a significant factor in preventing life-threatening arrhythmias. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Association between frequency of atrial and ventricular ectopic beats and biventricular pacing percentage and outcomes in patients with cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Ruwald, Martin H; Mittal, Suneet; Ruwald, Anne-Christine

    2014-01-01

    -defibrillator device with data available on biventricular pacing percentage and pre-implantation 24-h Holter recordings were included. Using logistic regression, we estimated the influence of ectopic beats on the percentage of biventricular pacing. Reverse remodeling was measured as reductions in atrial and left...

  3. The Managed Ventricular pacing versus VVI 40 Pacing (MVP) Trial: clinical background, rationale, design, and implementation.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Miller, Elaine Hogan; Sherfesee, Lou; Sheldon, Todd; Whellan, David

    2006-12-01

    Implantable cardioverter defibrillators (ICDs) reduce mortality among appropriately selected patients who have had or are at risk for life-threatening ventricular arrhythmia. Right ventricular apical (RVA) pacing has been implicated in worsening heart failure and death. The optimal pacemaker mode for bradycardia support while minimizing unnecessary and potentially harmful RVA pacing has not been determined. The Managed Ventricular pacing vs. VVI 40 Pacing Trial (MVP) is a prospective, multicenter, randomized, single-blind, parallel, controlled clinical trial designed to establish whether atrial-based dual-chamber managed ventricular pacing mode (MVP) is equivalent or superior to back-up only ventricular pacing (VVI 40) among patients with standard indications for ICD therapy and no indication for bradycardia pacing. The MVP Trial is designed with 80% power to detect a 10% reduction in the primary endpoint of new or worsening heart failure or all-cause mortality in the MVP-treated group. Approximately 1,000 patients at 80 centers in the United States, Canada, Western Europe, and Israel will be randomized to MVP or VVI 40 pacing after successful implantation of a dual-chamber ICD. Heart failure therapies will be optimized in accordance with evidence-based guidelines. Prespecified secondary endpoints will include ventricular arrhythmias, atrial fibrillation, new indication for bradycardia pacing, health-related quality of life, and cost effectiveness. Enrollment began in October 2004 and concluded in April 2006. The study will be terminated upon recommendation of the Data Monitoring Committee or when the last patient enrolled and surviving has reached a minimum 2 years of follow-up. The MVP Trial will meet the clinical need for carefully designed prospective studies to define the benefits of atrial-based dual-chamber minimal ventricular pacing versus single-chamber ventricular pacing in conventional ICD patients.

  4. Risk perception influences athletic pacing strategy.

    Science.gov (United States)

    Micklewright, Dominic; Parry, David; Robinson, Tracy; Deacon, Greg; Renfree, Andrew; St Clair Gibson, Alan; Matthews, William J

    2015-05-01

    The objective of this study is to examine risk taking and risk perception associations with perceived exertion, pacing, and performance in athletes. Two experiments were conducted in which risk perception was assessed using the domain-specific risk taking (DOSPERT) scale in 20 novice cyclists (experiment 1) and 32 experienced ultramarathon runners (experiment 2). In experiment 1, participants predicted their pace and then performed a 5-km maximum effort cycling time trial on a calibrated Kingcycle mounted bicycle. Split times and perceived exertion were recorded every kilometer. In experiment 2, each participant predicted their split times before running a 100-km ultramarathon. Split times and perceived exertion were recorded at seven checkpoints. In both experiments, higher and lower risk perception groups were created using median split of DOSPERT scores. In experiment 1, pace during the first kilometer was faster among lower risk perceivers compared with higher risk perceivers (t(18) = 2.0, P = 0.03) and faster among higher risk takers compared with lower risk takers (t(18) = 2.2, P = 0.02). Actual pace was slower than predicted pace during the first kilometer in both the higher risk perceivers (t(9) = -4.2, P = 0.001) and lower risk perceivers (t(9) = -1.8, P = 0.049). In experiment 2, pace during the first 36 km was faster among lower risk perceivers compared with higher risk perceivers (t(16) = 2.0, P = 0.03). Irrespective of risk perception group, actual pace was slower than predicted pace during the first 18 km (t(16) = 8.9, P risk perception groups. Initial pace is associated with an individual's perception of risk, with low perceptions of risk being associated with a faster starting pace. Large differences between predicted and actual pace suggest that the performance template lacks accuracy, perhaps indicating greater reliance on momentary pacing decisions rather than preplanned strategy.

  5. Temperature effects on aerobic scope and cardiac performance of European perch (Perca fluviatilis).

    Science.gov (United States)

    Jensen, Denise Lyager; Overgaard, Johannes; Wang, Tobias; Gesser, Hans; Malte, Hans

    2017-08-01

    Several recent studies have highlighted how impaired cardiac performance at high temperatures and in hypoxia may compromise the capacity for oxygen transport. Thus, at high temperatures impaired cardiac capacity is proposed to reduce oxygen transport to a degree that lowers aerobic scope and compromises thermal tolerance (the oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis). To investigate this hypothesis, we measured aerobic and cardiac performance of a eurythermal freshwater teleost, the European perch (Perca fluviatilis). Rates of oxygen consumption were measured during rest and activity at temperatures between 5°C and 27°C, and we evaluated cardiac function by in vivo measurements of heart rate and in vitro studies to determine contractility of myocardial strips. Aerobic scope increased progressively from 5°C to 21°C, after which it levelled off. Heart rate showed a similar response. We found little difference between resting and active heart rate at high temperature suggesting that increased cardiac scope during activity is primarily related to changes in stroke volume. To examine the effects of temperature on cardiac capacity, we measured isometric force development in electrically paced myocardial preparations during different combinations of temperature, pacing frequency, oxygenation and adrenergic stimulation. The force-frequency product increased markedly upon adrenergic stimulation at 21 and 27°C (with higher effects at 21°C) and the cardiac preparations were highly sensitive to hypoxia. These findings suggest that at (critically) high temperatures, cardiac output may diminish due to a decreased effect of adrenergic stimulation and that this effect may be further exacerbated if the heart becomes hypoxic. Hence cardiac limitations may contribute to the inability to increase aerobic scope at high temperatures in the European perch (Perca fluviatilis). Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Estimation of the effects of multipoint pacing on battery longevity in routine clinical practice.

    Science.gov (United States)

    Akerström, Finn; Narváez, Irene; Puchol, Alberto; Pachón, Marta; Martín-Sierra, Cristina; Rodríguez-Mañero, Moisés; Rodríguez-Padial, Luis; Arias, Miguel A

    2017-09-23

    Multipoint pacing (MPP) permits simultaneous multisite pacing of the left ventricle (LV); initial studies suggest haemodynamic and clinical benefits over conventional (single LV site) cardiac resynchronization therapy (CRT). The aim of this study was to estimate the impact of MPP activation on battery longevity in routine clinical practice. Patient (n = 46) and device data were collected from two centres at least 3 months after MPP-CRT device implantation. Multipoint pacing programming was based on the maximal possible anatomical LV1/LV2 separation according to three predefined LV pacing capture threshold (PCT) cut-offs (≤1.5 V; ≤4.0 V; and ≤6.5 V). Estimated battery longevity was calculated using the programmed lower rate limit, lead impedances, outputs, and pacing percentages. Relative to the longevity for conventional CRT using the lowest PCT (8.9 ± 1.2 years), MPP activation significantly shortened battery longevity for all three PCT cut-offs (≤1.5 V, -5.6%; ≤4.0 V, -16.9%; ≤6.5 V, -21.3%; P's battery longevity was significantly shortened for the MPP ≤ 4.0 V and ≤6.5 V cut-offs (-10.8 and -15.7%, respectively; P's battery longevity compared with that for conventional CRT configuration. When reasonable MPP LV vector PCTs (≤4.0 V) are achieved, the decrease in battery longevity is relatively small which may prompt the clinician to activate MPP. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  7. 42 CFR 460.60 - PACE organizational structure.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE organizational structure. 460.60 Section 460... ELDERLY (PACE) PACE Administrative Requirements § 460.60 PACE organizational structure. (a) A PACE organization must be, or be a distinct part of, one of the following: (1) An entity of city, county, State, or...

  8. Carbon monoxide exposure enhances arrhythmia after cardiac stress: involvement of oxidative stress.

    Science.gov (United States)

    André, Lucas; Gouzi, Fares; Thireau, Jérôme; Meyer, Gregory; Boissiere, Julien; Delage, Martine; Abdellaoui, Aldja; Feillet-Coudray, Christine; Fouret, Gilles; Cristol, Jean-Paul; Lacampagne, Alain; Obert, Philippe; Reboul, Cyril; Fauconnier, Jérémy; Hayot, Maurice; Richard, Sylvain; Cazorla, Olivier

    2011-11-01

    Arrhythmias following cardiac stress are a key predictor of death in healthy population. Carbon monoxide (CO) is a ubiquitous pollutant promoting oxidative stress and associated with hospitalization for cardiovascular disease and cardiac mortality. We investigated the effect of chronic CO exposure on the occurrence of arrhythmic events after a cardiac stress test and the possible involvement of related oxidative stress. Wistar rats exposed chronically (4 weeks) to sustained urban CO pollution presented more arrhythmic events than controls during recovery after cardiac challenge with isoprenaline in vivo. Sudden death occurred in 22% of CO-exposed rats versus 0% for controls. Malondialdehyde (MDA), an end-product of lipid peroxidation, was increased in left ventricular tissue of CO-exposed rats. Cardiomyocytes isolated from CO-exposed rats showed higher reactive oxygen species (ROS) production (measured with MitoSox Red dye), higher diastolic Ca(2+) resulting from SR calcium leak and an higher occurrence of irregular Ca(2+) transients (measured with Indo-1) in comparison to control cells after a high pacing sequence. Acute treatment with a ROS scavenger (N-acetylcysteine, 20 mmol/L, 1 h) prevented this sequence of alterations and decreased the number of arrhythmic cells following high pacing. Chronic CO exposure promotes oxidative stress that alters Ca(2+) homeostasis (through RYR2 and SERCA defects) and thereby mediates the triggering of ventricular arrhythmia after cardiac stress that can lead to sudden death.

  9. Biofilm on artificial pacemaker: fiction or reality?

    Science.gov (United States)

    Santos, Ana Paula Azevedo; Watanabe, Evandro; Andrade, Denise de

    2011-11-01

    Cardiac pacing through cardiac pacemaker is one of the most promising alternatives in the treatment of arrhythmias, but it can cause reactions natural or complex reactions, either early or late. This study aimed to describe the scientific evidence on the risk of infection and biofilm formation associated with cardiac pacemaker. This is a study of integrative literature review. It included 14 publications classified into three thematic categories: diagnosis (microbiological and/or clinical), complications and therapy of infections. Staphylococcus epidermidis and Staphylococcus aureus were the microorganisms most frequently isolated. It was not possible to determine the incidence of infection associated with pacemakers, since the studies were generally of prevalence. In terms of therapy, the complete removal of pacemakers stood out, especially in cases of suspected biofilm. Still controversial is the use of systemic antibiotic prophylaxis in reducing the incidence of infection associated with implantation of a pacemaker.

  10. Impact of right-ventricular apical pacing on the optimal left-ventricular lead positions measured by phase analysis of SPECT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Hung, Guang-Uei; Huang, Jin-Long; Lin, Wan-Yu; Tsai, Shih-Chung; Wang, Kuo-Yang; Chen, Shih-Ann; Lloyd, Michael S.; Chen, Ji

    2014-01-01

    The use of SPECT phase analysis to optimize left-ventricular (LV) lead positions for cardiac resynchronization therapy (CRT) was performed at baseline, but CRT works as simultaneous right ventricular (RV) and LV pacing. The aim of this study was to assess the impact of RV apical (RVA) pacing on optimal LV lead positions measured by SPECT phase analysis. This study prospectively enrolled 46 patients. Two SPECT myocardial perfusion scans were acquired under sinus rhythm with complete left bundle branch block and RVA pacing, respectively, following a single injection of 99m Tc-sestamibi. LV dyssynchrony parameters and optimal LV lead positions were measured by the phase analysis technique and then compared between the two scans. The LV dyssynchrony parameters were significantly larger with RVA pacing than with sinus rhythm (p ∝0.01). In 39 of the 46 patients, the optimal LV lead positions were the same between RVA pacing and sinus rhythm (kappa = 0.861). In 6 of the remaining 7 patients, the optimal LV lead positions were along the same radial direction, but RVA pacing shifted the optimal LV lead positions toward the base. The optimal LV lead positions measured by SPECT phase analysis were consistent, no matter whether the SPECT images were acquired under sinus rhythm or RVA pacing. In some patients, RVA pacing shifted the optimal LV lead positions toward the base. This study supports the use of baseline SPECT myocardial perfusion imaging to optimize LV lead positions to increase CRT efficacy. (orig.)

  11. Direct His bundle pacing post AVN ablation.

    Science.gov (United States)

    Lakshmanadoss, Umashankar; Aggarwal, Ashim; Huang, David T; Daubert, James P; Shah, Abrar

    2009-08-01

    Atrioventricular nodal (AVN) ablation with concomitant pacemaker implantation is one of the strategies that reduce symptoms in patients with atrial fibrillation (AF). However, the long-term adverse effects of right ventricular (RV) apical pacing have led to the search for alternating sites of pacing. Biventricular pacing produces a significant improvement in functional capacity over RV pacing in patients undergoing AVN ablation. Another alternative site for pacing is direct His bundle to reduce the adverse outcome of RV pacing. Here, we present a case of direct His bundle pacing using steerable lead delivery system in a patient with symptomatic paroxysmal AF with concurrent AVN ablation.

  12. Battery Malfunction of a Leadless Cardiac Pacemaker - A Worrisome Single-Center Experience.

    Science.gov (United States)

    Richter, Sergio; Döring, Michael; Ebert, Micaela; Bode, Kerstin; Müssigbrodt, Andreas; Sommer, Philipp; Husser, Daniela; Hindricks, Gerhard

    2018-03-14

    Leadless cardiac pacemaker (LCP) therapy has been established clinically as a feasible and safe alternative to conventional transvenous pacemaker therapy for patients with an indication for single-chamber right-ventricular pacing. 1-3 However, reports on loss of telemetry and pacing output due to abrupt battery failure called the safety of one of the two commercially available systems seriously into question. The initial battery advisory with the Nanostim™ LCP was issued by the manufacturer in October 2016, who instantly called a global stop to Nanostim™ implants. To this day, similar battery issues have not been described for the Micra™ transcatheter pacing system. Therefore, we thought to analyze the long-term pacemaker performance and rate of battery malfunction of the Nanostim™ LCP in our patient population.

  13. Spanish Pacemaker Registry. Thirteenth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2015).

    Science.gov (United States)

    Pombo Jiménez, Marta; Cano Pérez, Óscar; Fidalgo Andrés, María Luisa; Lorente Carreño, Diego; Coma Samartín, Raúl

    2016-12-01

    We describe the results of the analysis of the devices implanted and conveyed to the Spanish Pacemaker Registry in 2015. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. We received information from 111 hospitals, with a total of 12 555 cards, representing 32.1% of all the estimated activity. The use of conventional generators and resynchronization devices was 820 and 73 units per million population, respectively. The mean age of the patients receiving an implantation was 77.7 years, and more than 50% of the devices were implanted in patients over 80 years of age. Overall, 58.6% of the implants and 58.8% of the replacements were performed in men. All of the endocardial leads employed were bipolar, 81.5% had an active fixation system, and 16.5% were compatible with magnetic resonance. Although dual chamber sequential pacing continues to be more widespread, pacing with VVI/R mode is used because up to 23.8% of the patients with sinus node disease are in sinus rhythm, as are 24.1% of those with atrioventricular block. The total use of pacemaker generators in Spain has increased by about 5% with respect to 2014. The majority of the leads implanted are of active fixation, and less than 20% are protected from magnetic resonance. The factors directly related to the selection of pacing mode are age and sex. In around 20% of patients, the choice of the pacing mode could be improved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  14. Antiarrhythmic properties of atrial pacing.

    Science.gov (United States)

    Kliś, Magdalena; Sławuta, Agnieszka; Gajek, Jacek

    2017-01-01

    Bradycardia, atrial stretch and dilatation, autonomic nervous system disorders, and the presence of triggers such as atrial premature contractions, are factors which predispose a person to paroxysmal AF. Atrial pacing not only eliminates bradycardia but also prevents atrial premature contractions and dispersion of refractoriness, which are a substrate for atrial fibrillation. As the prolonged duration of atrial activation during pacing, especially from locations changing the physiological pattern of this activation (right atrium lateral wall, right atrium appendage), negatively influences both a mechanical and an electrical function of the atria, the atrial pacing site affects an atrial arrhythmogenesis. A conventional atrial lead location in the right atrium appendage causes non-physiological activation propagation, resulting in a prolongation of the activation time of both atria. This location is optimal according to a passive fixation of the atrial lead but the available contemporary active fixation leads could potentially be located in any area of the atrium. There is growing evidence of the benefit of pacing, imitating the physiological propagation of impulses within the atria. It seems that the Bachmann's bundle pacing is the best pacing site within the atria, not only positively influencing the atrial mechanical function but also best fulfilling the so-called atrial resynchronization function, in particular in patients with interatrial conduction delay. It can be effectively achieved using only one atrial electrode, and the slight shortening of atrioventricular conduction provides an additional benefit of this atrial pacing site.

  15. Sentence processing in an artificial language: Learning and using combinatorial constraints.

    Science.gov (United States)

    Amato, Michael S; MacDonald, Maryellen C

    2010-07-01

    A study combining artificial grammar and sentence comprehension methods investigated the learning and online use of probabilistic, nonadjacent combinatorial constraints. Participants learned a small artificial language describing cartoon monsters acting on objects. Self-paced reading of sentences in the artificial language revealed comprehenders' sensitivity to nonadjacent combinatorial constraints, without explicit awareness of the probabilities embedded in the language. These results show that even newly-learned constraints have an identifiable effect on online sentence processing. The rapidity of learning in this paradigm relative to others has implications for theories of implicit learning and its role in language acquisition. 2010 Elsevier B.V. All rights reserved.

  16. Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode designs.

    Science.gov (United States)

    Tyers, G F; Mills, P; Clark, J; Cheesman, M; Yeung-Lai-Wah, J A; Brownlee, R R

    1997-01-01

    The unacceptable rate of mechanical failures, threshold problems, and recalls experienced with many coaxial bipolar cardiac pacing lead designs are reviewed in detail. To address these problems, redundant insulation coradial atrial and ventricular tined leads (AL and VL, respectively) with iridium oxide electrodes were developed and subjected to extensive accelerated testing. There were no mechanical failures. The new lead body design proved to be much more durable than widely used trifilar MP35N configurations. The data reviewed and early and current test results are strongly supportive of tightly coupled insulation being a major factor in improving lead durability as long as the insulating material is not stressed. In addition to improving flex life, insulation adherence to the conductor may reduce the potential for ionic degradation. Pacing and sensing thresholds in animal studies of the new leads were within the reported range for leads with steroid eluting electrodes. A multicenter Canadian clinical trial was initiated with the first implant in early January 1994. By November 1995, 110 VL and 82 AL had been placed in 124 patients and followed for a mean of 11 +/- 6 months; maximum 21, total 1355. There were 60 males and 64 females with a mean age of 64 +/- 16 years, range 15-88. Primary indications for pacing were AV block in 61 patients, sick sinus syndrome in 53, vasovagal syncope in 4, and congestive heart failure in 7. Many patients had associated or primary tachyarrhythmias, including 111 with supraventricular and 12 with ventricular. Forty-two percent of patients (52/124) had prior cardiac procedures, including 18 open heart surgeries and 20 AV nodal ablations. At implant, 8 lead characteristics were rated good or excellent in 90% (746/829) of evaluations. X-ray visibility was of concern in 10% of patients (12/124). Three perioperative complications occurred, including displacement of one AL (1.2%) and one VL (0.9%). There were no subsequent mechanical

  17. Detection of Genuine conducting direction by radionuclide phase analysis in pseudo-RBBB in complete atrial-ventricular block patients with apical pacing

    International Nuclear Information System (INIS)

    Chu, L.S.; Liu, R.S.; Chang, C.P.; Wu, LC; Liou, J.Y.; Chen, W.L.; Kong, C.W.; Liao, S.Q.

    2004-01-01

    Objective: Apical pacing may cause ECG change mimicking right bundle branch block (RBBB) in patient with complete atrial-ventricular block (CAVB). The aim of this study was to differentiate pseudo-RBBB in CAVB patients after apical pacing. Methods: Nine patients of CAVB with apical pacing (6 man, 3 female, mean age=67+10 yrs, age ranged: 51-78 yrs) were studied, Red cells were labeled in vivo by an i.v. injection of 740 MBq of 99m Tc-pertechnetate proceeded by 3 mg of stannous pyrophosphate. After equilibration of the tracer, cardiac blood pool imaging was performed in modified 45 degree LAO position to isolate optimally the left ventricle. ECG gated data were collected into a series of 16 images of 64x64 pixels that span an averaged cardiac cycle. The acquired data were processed with equalization of the total activity in each image, followed by a 9-point spatial and a 3-pint temporal smoothing. First harmonic Fourier analysis was used to generate phase and amplitude images. The synchronism in the blood volume changes between and within the right and left ventricles was evaluated by means of the first harmonic amplitude/phase patterns. In a typical RBBB, the amplitude/phase histogram was bimodal with the difference between the mean phase of both ventricles ranging from 18 degree to 48 degree. The earliest phase was in the left ventricle and spreads via the apex to the right ventricle. Vector-cardiogram was performed for each patient to assess the conductive abnormalities. Results: All nine patients had ECG findings of RBBB. However, the phase alteration during cardiac cycle showed first exposed focus from apex, followed by bimodally distribution to the right ventricle and then procession of activation to left ventricle. Vector-cardiogram showed the electromotive forces going initially to the right, then to the left, and finally back to the right, which is different from typical RBBB with major QRS deflection downward in lead I and left chest leads, upward in the

  18. Pacing and Defibrillators in Complex Congenital Heart Disease

    Science.gov (United States)

    Chubb, Henry; O’Neill, Mark; Rosenthal, Eric

    2016-01-01

    Device therapy in the complex congenital heart disease (CHD) population is a challenging field. There is a myriad of devices available, but none designed specifically for the CHD patient group, and a scarcity of prospective studies to guide best practice. Baseline cardiac anatomy, prior surgical and interventional procedures, existing tachyarrhythmias and the requirement for future intervention all play a substantial role in decision making. For both pacing systems and implantable cardioverter defibrillators, numerous factors impact on the merits of system location (endovascular versus non-endovascular), lead positioning, device selection and device programming. For those with Fontan circulation and following the atrial switch procedure there are also very specific considerations regarding access and potential complications. This review discusses the published guidelines, device indications and the best available evidence for guidance of device implantation in the complex CHD population. PMID:27403295

  19. A devices' game of thrones: cardiac resynchronization therapy vs. pacemaker.

    Science.gov (United States)

    Moura-Ferreira, Sara; Gonçalves, Helena; Oliveira, Marco; Primo, João; Fonseca, Paulo; Ribeiro, José; Santos, Elisabeth; Pelicano, Nuno; Martins, Dinis; Gama, Vasco

    2017-12-01

    Oversensing can interfere with biventricular pacing. Cardiac Resynchronization Therapy (CRT) output inhibition due to automatic brady mode change from a sensing to a pacing mode of a previously implanted pacemaker as it reached battery capacity depleted indicator has not been previously published in the medical literature. We report the first case of CRT output inhibition in a pacemaker dependent patient due to electrical stimuli from a previously right-sided implanted pacemaker, after unaware reversion of OVO mode (O = no chambers paced; V = ventricular sensing; O = no response to sensing) to backup VVI (V = ventricular pacing; V = ventricular sensing; I = inhibitory response to sensing) when it reached the elective replacement interval. This paper emphasizes the importance of knowing the distinct pacemaker brady mode behaviours after battery capacity depleted indicator has been reached, according to the pacemakers' manufacturer, including the possibility of automatic brady mode change from sensing to pacing mode. It also highlights the potential for severe bradycardia or asystole of this automatic brady mode change from a previously implanted pacemaker in pacemaker dependent patients submitted to CRT upgrade. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  20. Ventricular, but not atrial, M2-muscarinic receptors increase in the canine pacing-overdrive model of heart failure.

    Science.gov (United States)

    Wilkinson, M; Giles, A; Armour, J A; Cardinal, R

    1996-01-01

    To investigate the effects of heart failure induced by chronic rapid ventricular pacing (six weeks) on canine atrial and ventricular muscarinic receptors. Dogs (n = 4) were fitted with a bipolar pacing electrode connected to a Medtronic pacemaker set at 240 stimuli/min. Pacing was maintained for six weeks. Tissue samples obtained from the left atrium and ventral wall of the left ventricle were frozen at -70 degrees C. Control tissue was obtained from normal dogs (n = 6) following anesthesia and thoracotomy. M2-muscarinic receptors were characterized and quantified in tissue micropunches using the hydrophilic ligand [3H] N-methyl-scopolamine (NMS). Cardiac tissue bound [3H] NMS with the specificity of an M2 subtype. Tachycardia-induced heart failure did not affect atrial muscarinic receptors but signify left ventricular myocytes (control 160.0 +/- 10.0 fmol/mg protein versus heart failure 245.0 +/- 25.0 fmol/mg protein; P failure was accompanied by an increase (+ 53%) in ventricular, but not atrial, M2 receptors compared with normal dogs.

  1. Artificial life: The coming evolution

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J.D. (Los Alamos National Lab., NM (USA) Santa Fe Inst., NM (USA)); Belin, A.d' A. (Shute, Mihaly, and Weinberger, Santa Fe, NM (USA))

    1990-01-01

    Within fifty to a hundred years a new class of organisms is likely to emerge. These organisms will be artificial in the sense that they will originally be designed by humans. However, they will reproduce, and will evolve into something other than their initial form; they will be alive'' under any reasonable definition of the word. These organisms will evolve in a fundamentally different manner than contemporary biological organisms, since their reproduction will be under at least partial conscious control, giving it a Lamarckian component. The pace of evolutionary change consequently will be extremely rapid. The advent of artificial life will be the most significant historical event since the emergence of human beings. The impact on humanity and the biosphere could be enormous, larger than the industrial revolution, nuclear weapons, or environmental pollution. We must take steps now to shape the emergence of artificial organisms; they have potential to be either the ugliest terrestrial disaster, or the most beautiful creation of humanity. 22 refs., 3 figs.

  2. Period doubling cascades of limit cycles in cardiac action potential models as precursors to chaotic early Afterdepolarizations.

    Science.gov (United States)

    Kügler, Philipp; Bulelzai, M A K; Erhardt, André H

    2017-04-04

    Early afterdepolarizations (EADs) are pathological voltage oscillations during the repolarization phase of cardiac action potentials (APs). EADs are caused by drugs, oxidative stress or ion channel disease, and they are considered as potential precursors to cardiac arrhythmias in recent attempts to redefine the cardiac drug safety paradigm. The irregular behaviour of EADs observed in experiments has been previously attributed to chaotic EAD dynamics under periodic pacing, made possible by a homoclinic bifurcation in the fast subsystem of the deterministic AP system of differential equations. In this article we demonstrate that a homoclinic bifurcation in the fast subsystem of the action potential model is neither a necessary nor a sufficient condition for the genesis of chaotic EADs. We rather argue that a cascade of period doubling (PD) bifurcations of limit cycles in the full AP system paves the way to chaotic EAD dynamics across a variety of models including a) periodically paced and spontaneously active cardiomyocytes, b) periodically paced and non-active cardiomyocytes as well as c) unpaced and spontaneously active cardiomyocytes. Furthermore, our bifurcation analysis reveals that chaotic EAD dynamics may coexist in a stable manner with fully regular AP dynamics, where only the initial conditions decide which type of dynamics is displayed. EADs are a potential source of cardiac arrhythmias and hence are of relevance both from the viewpoint of drug cardiotoxicity testing and the treatment of cardiomyopathies. The model-independent association of chaotic EADs with period doubling cascades of limit cycles introduced in this article opens novel opportunities to study chaotic EADs by means of bifurcation control theory and inverse bifurcation analysis. Furthermore, our results may shed new light on the synchronization and propagation of chaotic EADs in homogeneous and heterogeneous multicellular and cardiac tissue preparations.

  3. Improved quality of life after treatment of prolonged asystole during breath holding spells with a cardiac pacemaker

    Directory of Open Access Journals (Sweden)

    Bruno Kolterer

    2015-01-01

    Conclusion: Cardiac pacing using appropriate pacemaker settings seems effective in the prevention of LOC and reduction of the frequency of BHS. Our results imply a reduction of subjective stress levels of patients and parents as well as an increased quality of everyday life. After all, randomized controlled trials of the influence of cardiac pacemaker implantation on subjective stress levels in patients with BHS are needed.

  4. Spanish Pacemaker Registry. Twelfth Official Report of the Spanish Society of Cardiology Working Group on Cardiac Pacing (2014).

    Science.gov (United States)

    Cano Pérez, Óscar; Pombo Jiménez, Marta; Coma Samartín, Raúl

    2015-12-01

    This report describes the results of the analysis of pacemaker implant and replacement data submitted to the Spanish Pacemaker Registry in 2014, with special reference to pacing mode selection. The report is based on the processing of information provided by the European Pacemaker Patient Identification Card. Information was received from 117 hospitals, with a total of 12 358 cards, representing 34% of estimated activity. Use of conventional generators and resynchronization devices was 784 and 64.4 units per million population, respectively. The mean age of patients receiving an implant was 77.3 years. Men received 59% of implants and 56.4% of replacements. Most patients receiving generator implants and replacements were in the age range 80 to 89 years. Most endocardial leads used were bipolar, and 84.2% had an active fixation system. Pacing was in VVI/R mode despite being in sinus rhythm in 24.7% of patients with sick sinus syndrome and 24% of those with atrioventricular block. The use of pacemaker generators and resynchronization devices per million population continued to increase. Most implanted leads had active fixation and approximately 20% had magnetic resonance imaging protection. Age and sex directly influenced pacing mode selection, which could have been improved in more than 20% of cases. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  5. Positive pacing in elite IRONMAN triathletes.

    Science.gov (United States)

    Angehrn, Nicole; Rüst, Christoph A.; Nikolaidis, Pantelis T.; Rosemann, Thomas; Knechtle, Beat

    2016-12-31

    Pacing is known to influence athletic performance. For the Ironman triathlon program, a positive pacing strategy, i.e., the continuous decrease of speed over time was recommended. By analyzing split times, we assessed the pacing strategies of the top 100 finishers of the cycling part of 13 Ironman races and of the running part of 11 Ironman races taking place in 2014. Furthermore, sex-associated differences in performance and pacing strategies were calculated. We analyzed 7,687 cycling and 11,894 running split times of 1,392 triathletes (1,263 men, 129 women). Changes in speed were assessed using mixed-effects regression analyses. A continuous decrease in speed was observed during cycling in 10/13 races, and during running in 11/11 races. In 6/13 races, women decreased their speed during cycling significantly more than men. The running part showed no significant difference of changes in speed between the sexes. In summary, in the Ironman races evaluated, a positive pacing strategy was adopted in most races. Women were slower than men in 6/13 cycling races, but there was no difference between men and women in the run splits. Women used the same pacing strategy as men.

  6. Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay.

    Science.gov (United States)

    Varma, Niraj; O'Donnell, David; Bassiouny, Mohammed; Ritter, Philippe; Pappone, Carlo; Mangual, Jan; Cantillon, Daniel; Badie, Nima; Thibault, Bernard; Wisnoskey, Brian

    2018-02-06

    QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced atrioventricular delay (default or programmable offset) according to intrinsic atrioventricular conduction. Seventy-five patients undergoing cardiac resynchronization therapy (age 66±11 years; 65% male; 32% with ischemic cardiomyopathy; LV ejection fraction 28±8%; QRS duration 162±16 ms) with intact atrioventricular conduction (PR interval 194±34, range 128-300 ms), left bundle branch block, and optimized LV lead position were studied at implant. QRS duration (QRSd) reduction was compared for the following pacing configurations: nominal simultaneous BiV (Mode I: paced/sensed atrioventricular delay=140/110 ms), BiV+SyncAV with 50 ms offset (Mode II), BiV+SyncAV with offset that minimized QRSd (Mode III), or LV-only pacing+SyncAV with 50 ms offset (Mode IV). The intrinsic QRSd (162±16 ms) was reduced to 142±17 ms (-11.8%) by Mode I, 136±14 ms (-15.6%) by Mode IV, and 132±13 ms (-17.8%) by Mode II. Mode III yielded the shortest overall QRSd (123±12 ms, -23.9% [ P <0.001 versus all modes]) and was the only configuration without QRSd prolongation in any patient. QRS narrowing occurred regardless of QRSd, PR, or LV-paced intervals, or underlying ischemic disease. Post-implant electrical optimization in already well-selected patients with left bundle branch block and optimized LV lead position is facilitated by patient-tailored BiV pacing adjusted to intrinsic atrioventricular timing using an automatic device-based algorithm. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. How do we perceive activity pacing in rheumatology care?

    DEFF Research Database (Denmark)

    Cuperus, N.; Vliet Vlieland, T.; Brodin, N.

    2015-01-01

    goals of activity pacing, behaviours of activity pacing (the actions people take to meet the goal of activity pacing), strategies to change behaviour in activity pacing (for example goal setting) and contextual factors that should be acknowledged when instructing activity pacing. Besides, topics......-management programs. However, despite its wide endorsement in clinical practice, to date activity pacing is still a poorly understood concept. Objectives: To achieve consensus by means of an international Delphi exercise on the most important aspects of activity pacing as an intervention within non...... for future research on activity pacing were formulated and prioritized. Results: Of the 60 panelists, nearly two third (63%) completed all four Delphi rounds. The panel prioritized 9 goals, 11 behaviours, 9 strategies to change behaviour and 10 contextual factors of activity pacing. These items were...

  8. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  9. Right Ventricular Pacing and Sensing Function in High Posterior Septal and Apical Lead Placement in Cardiac Resynchronization Therapy

    Directory of Open Access Journals (Sweden)

    H.M. Kristiansen, MD

    2012-01-01

    Conclusions: The RV-HS lead position demonstrated stable and acceptable long-term pacing and sensing function, with rates of complications comparable to conventional RV-A lead position in CRT. The RV-HS lead position is feasible in CRT-P.

  10. Helping Family Physicians Improve Their Cardiac Auscultation Skills with an Interactive CD-ROM.

    Science.gov (United States)

    Roy, Douglas; Sargeant, Joan; Gray, Jean; Hoyt, Brian; Allen, Michael; Fleming, Michael

    2002-01-01

    Physicians (n=42) studied cardiac auscultation using a 15-hour CD-ROM program. Nine months later, 21 who completed a posttest showed significant improvement in identifying heart sounds. CDs were valued for opportunities to review material at an individual pace. Lack of computer skills hindered use. (Contains 26 references.) (SK)

  11. [Cardiac resynchronization therapy for heart failure - from experimental pacing to evidence-based therapy].

    Science.gov (United States)

    Götze, S; Butter, C; Fleck, E

    2006-01-01

    Within the last decade, cardiac resynchronization therapy (CRT) has become an evidence-based cornerstone for a subset of patients with chronic heart failure. For those, who suffer from ischemic or non-ischemic cardiomyopathies at NYHA III or IV, have sinus rhythm, a left bundle branch block and a left ventricular ejection fraction below 35%, CRT has evolved as an important treatment option with promising results. Numerous studies have shown that in these patients pacemaker-mediated correction of intra- and interventicular conduction disturbances can improve not only clinical symptoms, exercise tolerance and the frequency of hospitalizations, but even more important the overall mortality. These clinical results are due to several functional aspects. In the failing heart characteristic intra- and interventricular alterations in electrical conduction result in mechanical asynchrony that leads to an abnormal contraction of the left ventricle with delayed activation of the lateral wall, a paradoxical septal movement, a reduced diastolic filling and a mitral regurgitation due to dyssynchrony of papillary muscle activation. It is conceivable that these functional changes have fatal consequences for the failing heart. AV-optimized left- or biventricular stimulation by modern pacemakers can correct the pathological dyssynchrony, thereby improving cardiac function and clinical outcome in these patients. Although tremendous progress in cardiac resynchronization therapy has been made during the last decade, a couple of questions still need to be resolved. Critical issues are the identification of patients, who will predictably benefit from CRT, the value of CRT-pacemakers versus CRT-ICDs, and the usefullness of CRT in patients with atrial fibrillation.

  12. Chronic performance of a leadless cardiac pacemaker: 1-year follow-up of the LEADLESS trial

    NARCIS (Netherlands)

    Knops, Reinoud E.; Tjong, Fleur V. Y.; Neuzil, Petr; Sperzel, Johannes; Miller, Marc A.; Petru, Jan; Simon, Jaroslav; Sediva, Lucie; de Groot, Joris R.; Dukkipati, Srinivas R.; Koruth, Jacob S.; Wilde, Arthur A. M.; Kautzner, Josef; Reddy, Vivek Y.

    2015-01-01

    A leadless cardiac pacemaker (LCP) system was recently introduced to overcome lead-related complications of conventional pacing systems. To date, long-term results of an LCP system are unknown. The aim of this study was to assess the complication incidence, electrical performance, and rate response

  13. Temporary emergency pacing-an orphan in district hospitals

    DEFF Research Database (Denmark)

    Gjesdal, Knut; Johansen, Jens Brock; Gadler, Fredrik

    2012-01-01

    This editorial discusses a report on the 1 year experience with temporary pacing, especially in the emergency setting, in several Norwegian district hospitals. The vast majority of the patients received transvenous temporary pacing, and the majority of leads were placed by noncardiologists....... The procedure times were long and complications were frequent. The organization of emergency pacing is discussed, and we suggest that unless qualified physicians can establish transvenous pacing, the patients who need that should be transferred with transcutaneous pacing as back-up during transport...

  14. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Nielsen, Jens Cosedis; Thomsen, Poul Erik B; Højberg, Søren

    2011-01-01

    In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any ...

  15. Effect of myocardial perfusion and metabolic interventions on cardiac kinetics of phenylpentadecanoic acid (IPPA) I 123

    Energy Technology Data Exchange (ETDEWEB)

    Reske, S.N.; Schoen, S.; Schmitt, W.; Knopp, R.; Winkler, C.; Machulla, H.J.

    1986-08-01

    The effect of regional myocardial perfusion and flow-independent adrenergic stimulation, as well as lactate-mediated inhibition of cardiac lipolysis, on cardiac IPPA uptake and metabolism was examined in canine hearts (flow studies) and in the isolated perfused Langendorff rat heart (metabolic interventions). In both normal and ischaemic myocardium, local perfusion is a major determinant of cardiac IPPA uptake. In pacing-induced hyperaemia, the strict flow-dependence of cardiac IPPA uptake is not preserved. Adrenergic stimulation raises the rate of oxidation of both palmitic acid /sup 14/C and IPPA. This change is reflected by increased metabolite production released into the perfusate and radioactivity clearance recorded externally. Lactate in high concentrations exerts the opposite effect on cardiac free fatty acid oxidation. IPPA is stored in this condition preferentially in tissue phospholipids and triglycerides.

  16. Effect of myocardial perfusion and metabolic interventions on cardiac kinetics of phenylpentadecanoic acid (IPPA) I 123

    International Nuclear Information System (INIS)

    Reske, S.N.; Schoen, S.; Schmitt, W.; Knopp, R.; Winkler, C.; Machulla, H.J.

    1986-01-01

    The effect of regional myocardial perfusion and flow-independent adrenergic stimulation, as well as lactate-mediated inhibition of cardiac lipolysis, on cardiac IPPA uptake and metabolism was examined in canine hearts (flow studies) and in the isolated perfused Langendorff rat heart (metabolic interventions). In both normal and ischaemic myocardium, local perfusion is a major determinant of cardiac IPPA uptake. In pacing-induced hyperaemia, the strict flow-dependence of cardiac IPPA uptake is not preserved. Adrenergic stimulation raises the rate of oxidation of both palmitic acid 14 C and IPPA. This change is reflected by increased metabolite production released into the perfusate and radioactivity clearance recorded externally. Lactate in high concentrations exerts the opposite effect on cardiac free fatty acid oxidation. IPPA is stored in this condition preferentially in tissue phospholipids and triglycerides. (orig.)

  17. Hypothesis: Low frequency heart rate variability (LF-HRV) is an input for undisclosed yet biological adaptive control, governing the cardiovascular regulations to assure optimal functioning.

    Science.gov (United States)

    Gabbay, Uri; Bobrovsky, Ben Zion

    2012-02-01

    Cardiovascular regulation is considered today as having three levels: autoregulations, neural regulations and hormonal regulations. We hypothesize that the cardiovascular regulation has an additional (fourth) control level which is outer, hierarchical (adaptive) loop where LF-HRV amplitude serves as a reference input which the neural cardiovascular center detects and responses in order to maintain LF-HRV around some prescribed level. Supporting evidences: LF-HRV absence during artificial cardiac pacing may be associated with "pacemaker syndrome" which had not been sufficiently understood regardless of apparently unimpaired cardiovascular performance. The hypothesis may provide an essential basis for understanding several cardiovascular morbidities and insight toward diagnostic measures and treatments (including but not limited to adding variability to the pulse generator of artificial pacemakers to eliminate "pace maker syndrome"). Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Echo determinants of dyssynchrony (atrioventricular and inter- and intraventricular) and predictors of response to cardiac resynchronization therapy.

    Science.gov (United States)

    Kapetanakis, Stamatis; Bhan, Amit; Monaghan, Mark J

    2008-10-01

    Cardiac resynchronization therapy (CRT) has revolutionized not only the treatment of chronic heart failure but also how we assess left ventricular (LV) dysfunction on echo. Increasingly, it has become clear that identifying and quantifying delays in events during the cardiac cycle is an important assessment in LV dysfunction as it has prognostic implications for patients undergoing CRT. The delays in atrioventricular, right-to-left ventricular, and LV segmental contraction have been shown to be important components in cardiac performance, and this review provides an overview of the commonest methods used for these assessments and their implications for selecting patients for biventricular pacing.

  19. Effect of short-term rapid ventricular pacing followed by pacing interruption on arterial blood pressure in healthy pigs and pigs with tachycardiomyopathy.

    Science.gov (United States)

    Skrzypczak, P; Zyśko, D; Pasławska, U; Noszczyk-Nowak, A; Janiszewski, A; Gajek, J; Nicpoń, J; Kiczak, L; Bania, J; Zacharski, M; Tomaszek, A; Jankowska, E A; Ponikowski, P; Witkiewicz, W

    2014-01-01

    Ventricular tachycardia may lead to haemodynamic deterioration and, in the case of long term persistence, is associated with the development of tachycardiomyopathy. The effect of ventricular tachycardia on haemodynamics in individuals with tachycardiomyopathy, but being in sinus rhythm has not been studied. Rapid ventricular pacing is a model of ventricular tachycardia. The aim of this study was to determine the effect of rapid ventricular pacing on blood pressure in healthy animals and those with tachycardiomyopathy. A total of 66 animals were studied: 32 in the control group and 34 in the study group. The results of two groups of examinations were compared: the first performed in healthy animals (133 examinations) and the second performed in animals paced for at least one month (77 examinations). Blood pressure measurements were taken during chronic pacing--20 min after onset of general anaesthesia, in baseline conditions (20 min after pacing cessation or 20 min after onset of general anaesthesia in healthy animals) and immediately after short-term rapid pacing. In baseline conditions significantly higher systolic and diastolic blood pressure was found in healthy animals than in those with tachycardiomyopathy. During an event of rapid ventricular pacing, a significant decrease in systolic and diastolic blood pressure was found in both groups of animals. In the group of chronically paced animals the blood pressure was lower just after restarting ventricular pacing than during chronic pacing. Cardiovascular adaptation to ventricular tachycardia develops with the length of its duration. Relapse of ventricular tachycardia leads to a blood pressure decrease more pronounced than during chronic ventricular pacing.

  20. Clinicohemodynamic and roentgenologic correlations in patients with artificial pacemakers

    International Nuclear Information System (INIS)

    Tatarchenko, I.P.; Iskenderov, B.G.; Koledinov, V.I.; Zhivotovskaya, G.G.

    1987-01-01

    The clinical pattern, central hemodynamics and roentgenologic data are studied in 34 patients with artificial cardiac pacemaker (ACP) to solve the problem on adequate medicamental therapy of heart failure (HF). Heart sizes and the state of a pulmonary image are estimated roentgenologically. Two types of cardiac-vessel system reactions on physical load: adequate and nonadequate - are detected. Implantation of ACP in patients with the nonadequate reaction does not lead to total liquidation of HF

  1. Clinicohemodynamic and roentgenologic correlations in patients with artificial pacemakers

    Energy Technology Data Exchange (ETDEWEB)

    Tatarchenko, I P; Iskenderov, B G; Koledinov, V I; Zhivotovskaya, G G

    1987-05-01

    The clinical pattern, central hemodynamics and roentgenologic data are studied in 34 patients with artificial cardiac pacemaker (ACP) to solve the problem on adequate medicamental therapy of heart failure (HF). Heart sizes and the state of a pulmonary image are estimated roentgenologically. Two types of cardiac-vessel system reactions on physical load: adequate and nonadequate - are detected. Implantation of ACP in patients with the nonadequate reaction does not lead to total liquidation of HF.

  2. Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.

    Science.gov (United States)

    Hanazaki, Kazuhiro; Munekage, Masaya; Kitagawa, Hiroyuki; Yatabe, Tomoaki; Munekage, Eri; Shiga, Mai; Maeda, Hiromichi; Namikawa, Tsutomu

    2016-09-01

    The incidence of diabetes is increasing at an unprecedented pace and has become a serious health concern worldwide during the last two decades. Despite this, adequate glycemic control using an artificial pancreas has not been established, although the 21st century has seen rapid developments in this area. Herein, we review current topics in glycemic control for both the wearable artificial pancreas for type 1 and type 2 diabetic patients and the bedside artificial pancreas for surgical diabetic patients. In type 1 diabetic patients, nocturnal hypoglycemia associated with insulin therapy remains a serious problem that could be addressed by the recent development of a wearable artificial pancreas. This smart phone-like device, comprising a real-time, continuous glucose monitoring system and insulin pump system, could potentially significantly reduce nocturnal hypoglycemia compared with conventional glycemic control. Of particular interest in this space are the recent inventions of a low-glucose suspend feature in the portable systems that automatically stops insulin delivery 2 h following a glucose sensor value <70 mg/dL and a bio-hormonal pump system consisting of insulin and glucagon pumps. Perioperative tight glycemic control using a bedside artificial pancreas with the closed-loop system has also proved safe and effective for not only avoiding hypoglycemia, but also for reducing blood glucose level variability resulting in good surgical outcomes. We hope that a more sophisticated artificial pancreas with closed-loop system will now be taken up for routine use worldwide, providing enormous relief for patients suffering from uncontrolled hyperglycemia, hypoglycemia, and/or variability in blood glucose concentrations.

  3. Keeping Pace with New Technology: An Introduction to Robotics, FORTH, and Artificial Intelligence.

    Science.gov (United States)

    Reck, Gene

    A course was developed to introduce students at a community college to four major areas of emphasis in emerging technologies: FORTH programming language, elementary electronic theory, robotics, and artificial intelligence. After a needs assessment indicated the importance of such a course, a pretest focusing on the four areas was given to students…

  4. Echocardiographic estimation of acute haemodynamic response during optimization of multisite pace-maker using different pacing modalities and atrioventricular delays

    Directory of Open Access Journals (Sweden)

    Šalinger-Martinović Sonja

    2009-01-01

    Full Text Available Background/Aim. Cardiac resynchronization therapy (CRT improves ventricular dyssynchrony and is associated with an improvement in symptoms, quality of life and prognosis in patients with severe heart failure and intraventricular conduction delay. Different pacing modalities produce variable activation patterns and may be a cause of different haemodynamic changes. The aim of our study was to investigate acute haemodynamic changes with different CRT configurations during optimization procedure. Methods. This study included 30 patients with severe left ventricular systolic dysfunction and left bundle branch block with wide QRS (EF 24.33 ± 3.7%, QRS 159 ± 17.3 ms, New York Heart Association III/IV 25/5 with implanted CRT device. The whole group of patients had severe mitral regurgitation in order to measure dP/dt. After implantation and before discharge all the patients underwent optimization procedure guided by Doppler echocardiography. Left and right ventricular pre-ejection intervals (LVPEI and RVPEI, interventricular mechanical delay (IVD and the maximal rate of ventricular pressure rise during early systole (max dP/dt were measured during left and biventricular pacing with three different atrioventricular (AV delays. Results. After CRT device optimization, optimal AV delay and CRT mode were defined. Left ventricular pre-ejection intervals changed from 170.5 ± 24.6 to 145.9 ± 9.5 (p < 0.001, RVPEI from 102.4 ± 15.9 to 119.8 ± 10.9 (p < 0.001, IVD from 68.1 ± 18.3 to 26.5 ± 8.2 (p < 0.001 and dP/dt from 524.2 ± 67 to 678.2 ± 88.5 (p < 0.01. Conclusion. In patients receiving CRT echocardiographic assessment of the acute haemodynamic response to CRT is a useful tool in optimization procedure. The variability of Doppler parameters with different CRT modalities emphasizes the necessity of individualized approach in optimization procedure.

  5. Diastolic And Systolic Right Ventricular Dysfunction Precedes Left Ventricular Dysfunction In Patients Paced From Right Ventricular Apex

    Directory of Open Access Journals (Sweden)

    Dwivedi SK

    2006-07-01

    Full Text Available Background: Cardiac dysfunction after right ventricular (RV apical pacing is well known but its extent, time frame of appearance and individual effect on left ventricular (LV, RV systolic and diastolic parameters has not evaluated in a systematic fashion. Methods: Patients with symptomatic bradycardia and ACC-AHA Class I indication for permanent pacemaker implantation (PPI were implanted a single chamber (VVI pacemaker. They were followed prospectively by echocardiographic examination which was done at baseline, 1 week, 1 month and 6 months after implantation. Parameters observed were chamber dimensions (M-line, chamber volumes, cardiac output (modified Simpson's method, systolic functions (ejection fraction, pre-ejection period, ejection time and ratio and diastolic functions( isovolumic relaxation time & deceleration time of left and right heart. Results: Forty eight consecutive patients (mean age 65.6±11.8 yrs, 66.7% males, mean EF 61.82±10.36% implanted a VVI pacemaker were enrolled in this study. The first significant change to appear in cardiac function after VVI pacing was in diastolic properties of RV as shown by increase in RV isovolumic relaxation time (IVRT from 65.89±15.93 to 76.58±17.00 ms,(p<0.001 at 1week and RV deceleration time (DT from 133.84±38.13 to 153.09±31.41 ms, (p=0.02 at 1 month. Increase in RV internal dimension (RVID from 1.26±0.41 to 1.44±0.44, (p<0.05 was also noticed at 1 week. The LV diastolic parameters were significantly altered after 1 month with increase in LV-IVRT from 92.36±21.47 to 117.24±27.21ms, (p<0.001 and increase in LV DT from 147.56±31.84 to 189.27±28.49ms,(p<0.01. This was followed by LV systolic abnormality which appeared at 6 months with an increase in LVPEP from 100.33±14.43 to 118.41±21.34ms, (p<0.001 and increase in LVPEP/LVET ratio from 0.34±0.46 to 0.44±0.10, (p<0.001]. The reduction in LV EF was manifested at 6 months falling from 61.82±10.36% to52.52±12.11%, (p<0

  6. Implanted artificial heart with radioisotope power source

    Energy Technology Data Exchange (ETDEWEB)

    Shumakov, V I; Griaznov, G M; Zhemchuzhnikov, G N; Kiselev, I M; Osipov, A P

    1983-02-01

    An atomic artificial heart for orthotopic implantation was developed with the following characteristics: volume, 1.2 L; weight, 1.5 kg; radioisotope power, 45 W; operating life, up to 5 years; hemodynamics, similar to natural hemodynamics. The artificial heart includes a thermal drive with systems for regulating power, feeding steam into the cylinders, return of the condensate to the steam generator, and delivery of power to the ventricles and heat container. The artificial heart is placed in an artificial pericardium partially filled with physiologic solution. It uses a steam engine with two operating cylinders that separately drive the left and right ventricles. There is no electronic control system in the proposed design. The operation of the heat engine is controlled, with preservation of autoregulation by the vascular system of the body. The separate drives for the ventricles is of primary importance as it provides for operation of the artificial heart through control of cardiac activity by venous return. Experimental testing on a hydromechanical bench demonstrated effective autoregulation.

  7. Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system.

    Science.gov (United States)

    Abiri, Parinaz; Abiri, Ahmad; Packard, René R Sevag; Ding, Yichen; Yousefi, Alireza; Ma, Jianguo; Bersohn, Malcolm; Nguyen, Kim-Lien; Markovic, Dejan; Moloudi, Shervin; Hsiai, Tzung K

    2017-07-21

    Pacemakers have existed for decades as a means to restore cardiac electrical rhythms. However, lead-related complications have remained a clinical challenge. While market-released leadless devices have addressed some of the issues, their pacer-integrated batteries cause new health risks and functional limitations. Inductive power transfer enables wireless powering of bioelectronic devices; however, Specific Absorption Rate and size limitations reduce power efficiency for biomedical applications. We designed a remote-controlled system in which power requirements were significantly reduced via intermittent power transfer to control stimulation intervals. In parallel, the cardiac component was miniaturized to facilitate intravascular deployment into the anterior cardiac vein. Given size constraints, efficiency was optimal via a circular receiver coil wrapped into a half-cylinder with a meandering tail. The pacemaker was epicardially tested in a euthanized pig at 60 beats per minute, 2 V amplitude, and 1 ms pulse width, restoring mean arterial pressure from 0 to 37 mmHg. Power consumption was 1 mW at a range of > 3 cm with no misalignment and at 2 cm with 45° displacement misalignment, 45° x-axis angular misalignment, or 45° y-axis angular misalignment. Thus, we demonstrated a remote-controlled miniaturized pacing system with low power consumption, thereby providing a basis for the next generation of wireless implantable devices.

  8. Pacing in Swimming: A Systematic Review.

    Science.gov (United States)

    McGibbon, Katie E; Pyne, D B; Shephard, M E; Thompson, K G

    2018-03-20

    Pacing strategy, or how energy is distributed during exercise, can substantially impact athletic performance and is considered crucial for optimal performance in many sports. This is particularly true in swimming given the highly resistive properties of water and low mechanical efficiency of the swimming action. The aim of this systematic review was to determine the pacing strategies utilised by competitive swimmers in competition and their reproducibility, and to examine the impact of different pacing strategies on kinematic, metabolic and performance variables. This will provide valuable and practical information to coaches and sports science practitioners. The databases Web of Science, Scopus, SPORTDiscus and PubMed were searched for published articles up to 1 August 2017. A total of 23 studies examining pool-based swimming competitions or experimental trials in English-language and peer-reviewed journals were included in this review. In short- and middle-distance swimming events maintenance of swimming velocity is critical, whereas in long-distance events a low lap-to-lap variability and the ability to produce an end spurt in the final lap(s) are key. The most effective strategy in the individual medley (IM) is to conserve energy during the butterfly leg to optimise performance in subsequent legs. The pacing profiles of senior swimmers remain relatively stable irrespective of opponents, competition stage or type, and performance time. Implementing event-specific pacing strategies should benefit the performance of competitive swimmers. Given differences between swimmers, there is a need for greater individualisation when considering pacing strategy selection across distances and strokes.

  9. Systematic review and meta-analysis of left ventricular endocardial pacing in advanced heart failure: Clinically efficacious but at what cost?

    Science.gov (United States)

    Graham, Adam J; Providenica, Rui; Honarbakhsh, Shohreh; Srinivasan, Neil; Sawhney, Vinit; Hunter, Ross; Lambiase, Pier

    2018-04-01

    Cardiac resynchronization using a left ventricular (LV) epicardial lead placed in the coronary sinus is now routinely used in the management of heart failure patients. LV endocardial pacing is an alternative when this is not feasible, with outcomes data sparse. To review the available evidence on the efficacy and safety of endocardial LV pacing via meta-analysis. EMBASE, MEDLINE, and COCHRANE databases with the search term "endocardial biventricular pacing" or "endocardial cardiac resynchronization" or "left ventricular endocardial" or "endocardial left ventricular." Comparisons of pre-and post-QRS width, LV ejection fraction (LVEF), and New York Heart Association (NYHA) functional classification was performed, and mean differences (and respective 95% confidence interval [CI]) applied as a measurement of treatment effect. Fifteen studies, including 362 patients, were selected. During a mean follow-up of 40 ± 24.5 months, death occurred in 72 patients (11 per 100 patient-years). Significant improvements in LVEF (mean difference 7.9%, 95% CI 5-10%, P < 0.0001; I 2  = 73%), QRS width (mean difference: -41% 95% -75 to -7%; P < 0.0001; I 2  = 94%), and NYHA class (mean difference: -1.06, 95% CI -1.2 to -0.9, P < 0.0001; I 2  = 60%), (all P < 0.0001) occurred. Stroke rate was 3.3-4.2 per 100 patient-years, which is higher than equivalent heart failure trial populations and recent meta-analysis that included small case series. LV endocardial lead implantation is a potentially efficacious alternative to CS lead placement, but preliminary data suggest a potentially higher risk of stroke during follow-up when compared to the expected incidence of stroke in similar cohorts of patients. © 2018 Wiley Periodicals, Inc.

  10. The pace of aging: Intrinsic time scales in demography

    Directory of Open Access Journals (Sweden)

    Tomasz Wrycza

    2014-05-01

    Full Text Available Background: The pace of aging is a concept that captures the time-related aspect of aging. It formalizesthe idea of a characteristic life span or intrinsic population time scale. In the rapidly developing field of comparative biodemography, measures that account for inter-speciesdifferences in life span are needed to compare how species age. Objective: We aim to provide a mathematical foundation for the concept of pace. We derive desiredmathematical properties of pace measures and suggest candidates which satisfy these properties. Subsequently, we introduce the concept of pace-standardization, which reveals differences in demographic quantities that are not due to pace. Examples and consequences are discussed. Conclusions: Mean life span (i.e., life expectancy from birth or from maturity is intuitively appealing,theoretically justified, and the most appropriate measure of pace. Pace-standardizationprovides a serviceable method for comparative aging studies to explore differences indemographic patterns of aging across species, and it may considerably alter conclusionsabout the strength of aging.

  11. Proton Beam Therapy Interference With Implanted Cardiac Pacemakers

    International Nuclear Information System (INIS)

    Oshiro, Yoshiko; Sugahara, Shinji; Noma, Mio; Sato, Masato; Sakakibara, Yuzuru; Sakae, Takeji; Hayashi, Yasutaka; Nakayama, Hidetsugu; Tsuboi, Koji; Fukumitsu, Nobuyoshi; Kanemoto, Ayae; Hashimoto, Takayuki; Tokuuye, Koichi

    2008-01-01

    Purpose: To investigate the effect of proton beam therapy (PBT) on implanted cardiac pacemaker function. Methods and Materials: After a phantom study confirmed the safety of PBT in patients with cardiac pacemakers, we treated 8 patients with implanted pacemakers using PBT to a total tumor dose of 33-77 gray equivalents (GyE) in dose fractions of 2.2-6.6 GyE. The combined total number of PBT sessions was 127. Although all pulse generators remained outside the treatment field, 4 patients had pacing leads in the radiation field. All patients were monitored by means of electrocardiogram during treatment, and pacemakers were routinely examined before and after PBT. Results: The phantom study showed no effect of neutron scatter on pacemaker generators. In the study, changes in heart rate occurred three times (2.4%) in 2 patients. However, these patients remained completely asymptomatic throughout the PBT course. Conclusions: PBT can result in pacemaker malfunctions that manifest as changes in pulse rate and pulse patterns. Therefore, patients with cardiac pacemakers should be monitored by means of electrocardiogram during PBT

  12. Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and design.

    Science.gov (United States)

    Quesada, Aurelio; Botto, Gianluca; Erdogan, Ali; Kozak, Milan; Lercher, Peter; Nielsen, Jens Cosedis; Piot, Olivier; Ricci, Renato; Weiss, Christian; Becker, Daniel; Wetzels, Gwenn; De Roy, Luc

    2008-03-01

    Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to conventional pacemaker and implantable cardioverter-defibrillator programming in terms of freedom from hospitalization for cardiovascular causes in a population of patients exposed to long periods of ventricular pacing. PreFER MVP is a prospective, 1:1 parallel, randomized (MVP ON/MVP OFF), single-blinded multi-centre trial. The study population consists of patients with more than 40% ventricular pacing documented with their previous device. Approximately, 600 patients will be randomized and followed for at least 24 months. The primary endpoint comprises cardiovascular hospitalization. The PreFER MVP trial is the first large prospective randomized clinical trial evaluating the effect of MVP in patients with a history of RV pacing.

  13. [Cardiac cachexia].

    Science.gov (United States)

    Miján, Alberto; Martín, Elvira; de Mateo, Beatriz

    2006-05-01

    Chronic heart failure (CHF), especially affecting the right heart, frequently leads to malnutrition. If the latter is severe and is combined to other factors, it may lead to cardiac cachexia. This one is associated to increased mortality and lower survival of patients suffering from it. The causes of cardiac cachexia are diverse, generally associated to maintenance of a negative energy balance, with increasing evidence of its multifactorial origin. Neurohumoral, inflammatory, immunological, and metabolic factors, among others, are superimposed in the patient with CHF, leading to involvement and deterioration of several organs and systems, since this condition affects both lean (or active cellular) mass and adipose and bone tissue osteoporosis. Among all, the most pronounced deterioration may be seen at skeletal muscle tissue, at both structural and functional levels, the heart not being spared. As for treatment, it should be based on available scientific evidence. Assessment of nutritional status of any patient with CHF is a must, with the requirement of nutritional intervention in case of malnutrition. In this situation, especially if accompanied by cardiac cachexia, it is required to modify energy intake and oral diet quality, and to consider the indication of specific complementary or alternative artificial nutrition. Besides, the causal relationship of the beneficial role of moderate physical exertion is increasing, as well as modulation of metabolic and inflammatory impairments observed in cardiac cachexia with several drugs, leading to a favorable functional and structural response in CHF patients.

  14. Web Tools: Keeping Learners on Pace

    Science.gov (United States)

    Kosloski, Mickey

    2016-01-01

    One of the greatest challenges in teaching technology and engineering is pacing. Some students grasp new technological concepts quickly, while others need repetition and may struggle to keep pace. This poses an obstacle for the technology and engineering teacher, and is particularly true when teaching students to build a website. However, there…

  15. Artificial Gravity with Ergometric Exercise Training Improves Cardiovascular Function in Ambulatory Men

    Science.gov (United States)

    Sun, Xi-Qing; Zhu, Chao; Shang, Shu; Yao, Yong-Jie

    2008-06-01

    The necessity of preventing physiological deconditioning in astronauts exposed to long-term space flights is well known. Artificial gravity training via short-arm centrifugation as a countermeasure to microgravity has been considered for many years. However, an optimal duration, level and rate of exposure to artificial gravity have not yet been determined. The purpose of the present study was to investigate the cardiovascular effects of three weeks of intermittent artificial gravity with ergometric exercise training on normal ambulatory men. During 3 weeks experiment, eight healthy male subjects received alternate +1 to +2 Gz (at the foot) short-arm centrifuge training with 30 W ergometric exercise for 30 min per day. Cardiac function, heart rate variability, heart rate and blood pressure were measured before and after training. Stroke volume and total peripheral resistance increased significantly after 3 weeks training, compared with the pre-training baseline. Left ventricular ejection time (LVET) and ejection fraction increased significantly after 3 weeks training, while heart rate, the ratio of pre-ejection period to LVET, and the ratio of low frequency to high frequency power decreased significantly after 3 weeks training. These results suggest that three weeks short-arm centrifuge training with ergometric exercise could improve human cardiac systolic and pumping functions, and increase cardiac vagal modulation.

  16. Long pacing pulses reduce phrenic nerve stimulation in left ventricular pacing.

    Science.gov (United States)

    Hjortshøj, Søren; Heath, Finn; Haugland, Morten; Eschen, Ole; Thøgersen, Anna Margrethe; Riahi, Sam; Toft, Egon; Struijk, Johannes Jan

    2014-05-01

    Phrenic nerve stimulation is a major obstacle in cardiac resynchronization therapy (CRT). Activation characteristics of the heart and phrenic nerve are different with higher chronaxie for the heart. Therefore, longer pulse durations could be beneficial in preventing phrenic nerve stimulation during CRT due to a decreased threshold for the heart compared with the phrenic nerve. We investigated if long pulse durations decreased left ventricular (LV) thresholds relatively to phrenic nerve thresholds in humans. Eleven patients, with indication for CRT and phrenic nerve stimulation at the intended pacing site, underwent determination of thresholds for the heart and phrenic nerve at different pulse durations (0.3-2.9 milliseconds). The resulting strength duration curves were analyzed by determining chronaxie and rheobase. Comparisons for those parameters were made between the heart and phrenic nerve, and between the models of Weiss and Lapicque as well. In 9 of 11 cases, the thresholds decreased faster for the LV than for the phrenic nerve with increasing pulse duration. In 3 cases, the thresholds changed from unfavorable for LV stimulation to more than a factor 2 in favor of the LV. The greatest change occurred for pulse durations up to 1.5 milliseconds. The chronaxie of the heart was significantly higher than the chronaxie of the phrenic nerve (0.47 milliseconds vs. 0.22 milliseconds [P = 0.029, Lapicque] and 0.79 milliseconds vs. 0.27 milliseconds [P = 0.033, Weiss]). Long pulse durations lead to a decreased threshold of the heart relatively to the phrenic nerve and may prevent stimulation of the phrenic nerve in a clinical setting. © 2013 Wiley Periodicals, Inc.

  17. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Anupama Shivaraju

    2018-01-01

    Full Text Available Objectives. The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR using aortic valve predilatation (AVPD with a small, nonocclusive balloon. Background. Balloon aortic valvuloplasty (BAV under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV. BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism. Methods. A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve. All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm without rapid pacing. Procedural data and clinical outcomes were analyzed. Results. The mean age of the cohort was 81±6 years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation was 13±9. Crossing the AV and prosthesis implantation was successful in all cases. The postprocedural mean AV gradient was 12±5 mmHg. There were no cases of aortic regurgitation ≥ grade 2. No periprocedural stroke occurred. One patient (2% with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR. Mortality was 0% at 30 days after procedure. Conclusion. In TAVR, AVPD with a small, nonocclusive balloon can be safely performed. By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV. Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.

  18. Global artificial photosynthesis project: a scientific and legal introduction.

    Science.gov (United States)

    Faunce, Thomas

    2011-12-01

    With the global human population set to exceed 10 billion by 2050, its collective energy consumption to rise from 400 to over 500 EJ/yr and with the natural environment under increasing pressure from these sources as well as from anthropogenic climate change, political solutions such as the creation of an efficient carbon price and trading scheme may arrive too late. In this context, the scientific community is exploring technological remedies. Central to these options is artificial photosynthesis--the creation, particularly through nanotechnology, of devices capable to doing what plants have done for millions of years - transforming sunlight, water and carbon dioxide into food and fuel. This article argues that a Global Artificial Photosynthesis (GAP) project can raise the public profile and encourage the pace, complexity and funding of scientific collaborations in artificial photosynthesis research. The legal structure of a GAP project will be critical to prevent issues such as state sovereignty over energy and food resources and corporate intellectual monopoly privileges unduly inhibiting the important contribution of artificial photosynthesis to global public health and environmental sustainability. The article presents an introduction to the scientific and legal concepts behind a GAP project.

  19. Neuregulin-1/erbB-activation improves cardiac function and survival in models of ischemic, dilated, and viral cardiomyopathy.

    Science.gov (United States)

    Liu, Xifu; Gu, Xinhua; Li, Zhaoming; Li, Xinyan; Li, Hui; Chang, Jianjie; Chen, Ping; Jin, Jing; Xi, Bing; Chen, Denghong; Lai, Donna; Graham, Robert M; Zhou, Mingdong

    2006-10-03

    We evaluated the therapeutic potential of a recombinant 61-residue neuregulin-1 (beta2a isoform) receptor-active peptide (rhNRG-1) in multiple animal models of heart disease. Activation of the erbB family of receptor tyrosine kinases by rhNRG-1 could provide a treatment option for heart failure, because neuregulin-stimulated erbB2/erbB4 heterodimerization is not only critical for myocardium formation in early heart development but prevents severe dysfunction of the adult heart and premature death. Disabled erbB-signaling is also implicated in the transition from compensatory hypertrophy to failure, whereas erbB receptor-activation promotes myocardial cell growth and survival and protects against anthracycline-induced cardiomyopathy. rhNRG-1 was administered IV to animal models of ischemic, dilated, and viral cardiomyopathy, and cardiac function and survival were evaluated. Short-term intravenous administration of rhNRG-1 to normal dogs and rats did not alter hemodynamics or cardiac contractility. In contrast, rhNRG-1 improved cardiac performance, attenuated pathological changes, and prolonged survival in rodent models of ischemic, dilated, and viral cardiomyopathy, with the survival benefits in the ischemic model being additive to those of angiotensin-converting enzyme inhibitor therapy. In addition, despite continued pacing, rhNRG-1 produced global improvements in cardiac function in a canine model of pacing-induced heart failure. These beneficial effects make rhNRG-1 promising as a broad-spectrum therapeutic for the treatment of heart failure due to a variety of common cardiac diseases.

  20. 42 CFR 460.90 - PACE benefits under Medicare and Medicaid.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false PACE benefits under Medicare and Medicaid. 460.90 Section 460.90 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... FOR THE ELDERLY (PACE) PACE Services § 460.90 PACE benefits under Medicare and Medicaid. If a Medicare...

  1. Classification of Atrial Septal Defect and Ventricular Septal Defect with Documented Hemodynamic Parameters via Cardiac Catheterization by Genetic Algorithms and Multi-Layered Artificial Neural Network

    Directory of Open Access Journals (Sweden)

    Mustafa Yıldız

    2012-08-01

    Full Text Available Introduction: We aimed to develop a classification method to discriminate ventricular septal defect and atrial septal defect by using severalhemodynamic parameters.Patients and Methods: Forty three patients (30 atrial septal defect, 13 ventricular septal defect; 26 female, 17 male with documentedhemodynamic parameters via cardiac catheterization are included to study. Such parameters as blood pressure values of different areas,gender, age and Qp/Qs ratios are used for classification. Parameters, we used in classification are determined by divergence analysismethod. Those parameters are; i pulmonary artery diastolic pressure, ii Qp/Qs ratio, iii right atrium pressure, iv age, v pulmonary arterysystolic pressure, vi left ventricular sistolic pressure, vii aorta mean pressure, viii left ventricular diastolic pressure, ix aorta diastolicpressure, x aorta systolic pressure. Those parameters detected from our study population, are uploaded to multi-layered artificial neuralnetwork and the network was trained by genetic algorithm.Results: Trained cluster consists of 14 factors (7 atrial septal defect and 7 ventricular septal defect. Overall success ratio is 79.2%, andwith a proper instruction of artificial neural network this ratio increases up to 89%.Conclusion: Parameters, belonging to artificial neural network, which are needed to be detected by the investigator in classical methods,can easily be detected with the help of genetic algorithms. During the instruction of artificial neural network by genetic algorithms, boththe topology of network and factors of network can be determined. During the test stage, elements, not included in instruction cluster, areassumed as in test cluster, and as a result of this study, we observed that multi-layered artificial neural network can be instructed properly,and neural network is a successful method for aimed classification.

  2. Pacing: a concept analysis of the chronic pain intervention.

    Science.gov (United States)

    Jamieson-Lega, Kathryn; Berry, Robyn; Brown, Cary A

    2013-01-01

    The intervention of pacing is regularly recommended for chronic pain patients. However, pacing is poorly defined and appears to be interpreted in varying, potentially contradictory manners within the field of chronic pain. This conceptual lack of clarity has implications for effective service delivery and for researchers' ability to conduct rigorous study. An examination of the background literature demonstrates that while pacing is often one part of a multidisciplinary pain management program, outcome research is hindered by a lack of a clear and shared definition of this currently ill-defined construct. To conduct a formal concept analysis of the term 'pacing'. A standardized concept analysis process (including literature scoping to identify all uses of the concept, analysis to determine defining attributes of the concept and identification of model, borderline and contrary cases) was used to determine what the concept of pacing does and does not represent within the current evidence base. A conceptual model including the core attributes of action, time, balance, learning and self-management emerged. From these attributes, an evidence-based definition for pacing was composed and distributed to stakeholders for review. After consideration of stakeholder feedback, the emergent definition of pacing was finalized as follows: "Pacing is an active self-management strategy whereby individuals learn to balance time spent on activity and rest for the purpose of achieving increased function and participation in meaningful activities". The findings of the present concept analysis will help to standardize the use and definition of the term pacing across disciplines for the purposes of both pain management and research.

  3. Anesthesia for robotic cardiac surgery: An amalgam of technology and skill

    Directory of Open Access Journals (Sweden)

    Chauhan Sandeep

    2010-01-01

    Full Text Available The surgical procedures performed with robtic assitance and the scope for its future assistance is endless. To keep pace with the developing technologies in this field it is imperative for the cardiac anesthesiologists to have aworking knowledge of these systems, recognize potential complications and formulate an anesthetic plan to provide safe patient care. Challenges posed by the use of robotic systems include, long surgical times, problems with one lung anesthesia in presence of coronary artery disease, minimally invasive percutaneous cardiopulmonary bypass management and expertise in Trans-Esophageal Echocardiography. A long list of cardiac surgeries are performed with the use of robotic assistance, and the list is continuously growing as surgical innovation crosses new boundaries. Current research in robotic cardiac surgery like beating heart off pump intracardic repair, prototype epicardial crawling device, robotic fetal techniques etc. are in the stage of animal experimentation, but holds a lot of promise in future

  4. Current state of total artificial heart therapy and introduction of the most important total artificial heart systems.

    Science.gov (United States)

    Spiliopoulos, Sotirios; Hergesell, Vera; Wasler, Andrae; Dapunt, Otto

    2018-06-14

    Due to the declining instances of organ donation, total artificial heart (TAH) therapy is of increasing importance for the management of end-stage biventricular heart failure. We introduce the currently most important established and novel TAH systems (SynCardia, CARMAT, ReinHeart, BiVACOR), report clinical outcomes and discuss technical requirements for the successful implementation of TAH therapy as an alternative to cardiac transplantation.

  5. Effect of biventricular pacing on heart function evaluated by gated blood pool study in patients with end-stage heart failure

    International Nuclear Information System (INIS)

    Cholewinski, W.; Tarkowska, A.; Stefaniak, B.; Poniatowicz-Frasunek, E.; Kutarski, A.; Oleszczak, K.

    2002-01-01

    Biventricular cardiac pacing has been used as a complementary form of therapy in patients with severe heart failure. The aim of this study was to evaluate the effect of the synchronous stimulation of both ventricles on the heart function measured by gated blood pool study (GBP). Ten patients (9 men and 1 woman aged 53-74 years) with end-stage heart failure (HF) were studied. In all patients long-term biventricular pacing (BV) was applied. The obtained results were compared with single-chamber stimulation in 5 patients and with sinus rhythm (SR) in 8 patients. All patients underwent repeated GBP with RBC labelled with 740 MBq of 99m Tc-pertechnetate. The LVEF was calculated according to the standard method based on the count rates. Phase analysis was performed with the standard method using first Fourier element. Clinically in almost all patients moderate to important symptomatic improvement has been observed. The analysis of LVEF values revealed that BV pacing resulted in significantly higher values only in comparison with SR (21.6% ±10.3 v. 20.1% ± 10.1; p o± 29.6 v. 13.4 o± 37.6 and 7.4 o± 26.5 v. 6.0 o± 17.1, respectively). However, in comparison with LV pacing, BV stimulation revealed a change of dominant conduction abnormalities with a delay of RV contraction in relation to LV (9.0 o± 17.5 v. -3.0 o± 11.4). Biventricular pacing results in slight improvement of LVEF in patients with heart failure and can be considered a promising approach in patients with end-stage heart failure. Synchronous stimulation of both ventricles not always results in decrease of interventricular shift, however that observation requires further studies on a larger population. (author)

  6. Pace of work stabilising, but not in all sectors

    NARCIS (Netherlands)

    Houtman, I.L.D.

    2003-01-01

    The Netherlands had the highest level of work pace in Europe but this position has levelled off in the last five years. There appears to be a general trend towards a decline in work pace. However, different sectors show varying trends, with work pace on the rise again in the education, health and

  7. Pace studying worldwide coke production

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Pace Consultants Inc., Houston, has started a multiclient study of world-wide petroleum coke production, examining environmental initiatives and eventually forecasting prices of fuel grade coke. Pace expects coker expansions, increased operating severity, and reduced cycle times to boost coke supply to more than 50 million metric tons/year in 2000, compared with 39.7 million metric tons in 1992. Increased supply and tightened environmental rules in countries consuming large amounts of petroleum coke will be the main factors affecting coke markets. The paper discusses coke quality and the Japanese market

  8. PACE and the Federal Housing Finance Agency (FHFA)

    Energy Technology Data Exchange (ETDEWEB)

    Zimring, Mark; Fuller, Merrian

    2010-03-17

    The FHFA regulates Fannie Mae, Freddie Mac, and the 12 Federal Home Loan Banks (the government-sponsored enterprises - GSEs). On June 18, 2009, James B. Lockhart III, then Director of FHFA, released a letter expressing concern about the negative impact of energy loan tax assessment programs (ELTAPs) - also known as Property Assessed Clean Energy (PACE) programs - on both the housing finance system and homeowner program participants. Subsequently, a number of PACE proponents responded to the concerns laid out in the FHFA letter. In early Fall 2009, word circulated that FHFA was planning to follow its June letter with guidance to other agencies, possibly including Fannie Mae and Freddie Mac, discouraging them from buying loans on properties subject to PACE-type assessment liens. This triggered a second round of stakeholder letters, several of which were addressed to President Obama. On October 18, 2009, the White House, in what some believe was an attempt to obviate the need for FHFA guidance, released a Policy Framework for PACE Financing Programs that outlined best practices guidance for homeowner and lender protection. As of February 2010, FHFA and the GSEs have agreed to monitor PACE programs and work with stakeholders and the Administration to consider additional guidance beyond the Policy Framework and to collect more information on PACE program efficacy and risks. A summary of the communications timeline and highlights of the communications are provided.

  9. Interatrial septum pacing decreases atrial dyssynchrony on strain rate imaging compared with right atrial appendage pacing.

    Science.gov (United States)

    Yasuoka, Yoshinori; Abe, Haruhiko; Umekawa, Seiko; Katsuki, Keiko; Tanaka, Norio; Araki, Ryo; Imanaka, Takahiro; Matsutera, Ryo; Morisawa, Daisuke; Kitada, Hirokazu; Hattori, Susumu; Noda, Yoshiki; Adachi, Hidenori; Sasaki, Tatsuya; Miyatake, Kunio

    2011-03-01

    Interatrial septum pacing (IAS-P) decreases atrial conduction delay compared with right atrial appendage pacing (RAA-P). We evaluate the atrial contraction with strain rate of tissue Doppler imaging (TDI) during sinus activation or with IAS-P or RAA-P. Fifty-two patients with permanent pacemaker for sinus node disease were enrolled in the study. Twenty-three subjects were with IAS-P and 29 with RAA-P. The time from end-diastole to peak end-diastolic strain rate was measured and corrected with RR interval on electrocardiogram. It was defined as the time from end-diastole to peak end-diastolic strain rate (TSRc), and the balance between maximum and minimum TSRc at three sites (ΔTSRc) was compared during sinus activation and with pacing rhythm in each group. There were no significant differences observed in general characteristics and standard echocardiographic parameters except the duration of pacing P wave between the two groups. The duration was significantly shorter in the IAS-P group compared with the RAA-P group (95 ± 34 vs 138 ± 41; P = 0.001). TSRc was significantly different between sinus activation and pacing rhythm (36.3 ± 35.7 vs 61.6 ± 36.3; P = 0.003) in the RAA-P group, whereas no significant differences were observed in the IAS-P group (25.4 ± 12.1 vs 27.7 ± 14.7; NS). During the follow-up (mean 2.4 ± 0.7 years), the incidence of paroxysmal atrial fibrillation (AF) conversion to permanent AF was not significantly different between the two groups. IAS-P decreased the contraction delay on atrial TDI compared to RAA-P; however, it did not contribute to the reduction of AF incidence in the present study. ©2010, The Authors. Journal compilation ©2010 Wiley Periodicals, Inc.

  10. Comparison of pacing algorithms to avoid unnecessary ventricular pacing in patients with sick sinus node syndrome: a single-centre, observational, parallel study.

    Science.gov (United States)

    Poghosyan, Hermine R; Jamalyan, Smbat V

    2012-10-01

    Reduction of unnecessary ventricular pacing (uVP) is an essential component in the treatment strategy in any pacing population in general. The aim of this study was to evaluate the efficacy of different algorithms to reduce uVP in an adult population with sick sinus syndrome (SSS) treated outside of clinical trials. Evaluation of the relationship between different types of pacing algorithms and clinical outcomes is also provided. This was a single-centre, observational, parallel study, based on retrospective analysis of the Arrhythmology Cardiology Center of Armenia electronic clinical database. This study evaluated atrial pacing percentage (AP%), ventricular pacing percentage (VP%), and the incidence of atrial high rate episodes in 56 patients with SSS using three different pacing strategies: managed VP, search atrioventricular (AV), and fixed long AV. We did not find statistically significant differences in the amount of VP between the groups. Although the atrial high rate percentage (AHR%) tended to be higher in the fixed long AV group, this difference was not statistically significant. Mean VP% and AP% were similar in all three groups. In our study, all three programmed strategies produced the same mean AP% and VP%, and were equally efficient in uVP reduction. There was no relationship between chosen algorithms and the incidence of pacemaker syndrome, hospitalizations, or change in New York Heart Association class. The percentage of AHR was not associated with pacing strategy or co-morbidities but showed borderline correlation with left atrial size.

  11. Total Artificial Heart Implantation after Excision of Right Ventricular Angiosarcoma.

    Science.gov (United States)

    Bruckner, Brian A; Abu Saleh, Walid K; Al Jabbari, Odeaa; Copeland, Jack G; Estep, Jerry D; Loebe, Matthias; Reardon, Michael J

    2016-06-01

    Primary cardiac sarcomas, although rare, are aggressive and lethal, requiring thorough surgical resection and adjuvant chemotherapy for the best possible outcome. We report the case of a 32-year-old woman who underwent total artificial heart implantation for right-sided heart failure caused by right ventricular angiosarcoma. For the first several weeks in intensive care, the patient recovered uneventfully. However, a postoperative liver biopsy indicated hepatocellular injury consistent with preoperative chemotherapy. She developed continuing liver failure, from which she died despite good cardiac function.

  12. Wide QRS tachycardia in a patient with pre excitation; what are the pathways involved? Pacing manoeuvres to characterize a unique pathway

    Directory of Open Access Journals (Sweden)

    Krishna Kumar Mohanan Nair

    2017-03-01

    Full Text Available A 30year old patient presented to us with recurrent episodes of palpitation and documented tachycardia. In all his presentations a wide QRS tachycardia was recorded. The baseline ECG showed pre excitation. The 12 lead ECG of the tachycardia and the baseline ECG is shown in Fig. 1A. During EP study the patient had baseline pre excitation and the HV interval was 16 ms. A duo-decapolar halo (HL catheter was used to map right atrium and a decapolar coronary sinus (CS catheter was used to map coronary sinus. In addition a His bundle and right ventricular (RV quadripolar catheters were used. The delta wave morphology was suggestive of a posteroseptal pathway. Ventricular pacing from RV apex showing central decremental conduction with ventriculo-atrial Wenkebach at 290 ms. Ventricular extrastimulation also showed decremental conduction and VA block at S1 S2 of 400,240. The intra cardiac recording of tachycardia and its initiation is shown in Fig. 1B. Pacing from lateral RA (HL 5, 6 electrodes showed progressive pre excitation with extrastimulation and induction of tachycardia. The QRS morphology was same as the patient's clinical tachycardia and the tachycardia cycle length (TCL was 304 ms. An atrial entrainment protocol showed entrainment with the same QRS morphology while pacing from right atrium. The VA interval of the first return cycle was the same as the subsequent VA intervals. A ventricular entrainment protocol showed V-A-V response and post pacing interval of 414 ms. An atrial extra systole was given from the mid CS electrodes (CS 5, 6 – the effect is shown in Fig. 3. In sinus rhythm a parahisian pacing manoeuvre was done as shown in Fig. 4A. What is the mechanism of the tachycardia and what are the pathways involved?

  13. Social Interaction in Self-Paced Distance Education

    Science.gov (United States)

    Anderson, Terry; Upton, Lorne; Dron, Jon; Malone, Judi; Poelhuber, Bruno

    2015-01-01

    In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions…

  14. PACE and the Medicare+Choice risk-adjusted payment model.

    Science.gov (United States)

    Temkin-Greener, H; Meiners, M R; Gruenberg, L

    2001-01-01

    This paper investigates the impact of the Medicare principal inpatient diagnostic cost group (PIP-DCG) payment model on the Program of All-Inclusive Care for the Elderly (PACE). Currently, more than 6,000 Medicare beneficiaries who are nursing home certifiable receive care from PACE, a program poised for expansion under the Balanced Budget Act of 1997. Overall, our analysis suggests that the application of the PIP-DCG model to the PACE program would reduce Medicare payments to PACE, on average, by 38%. The PIP-DCG payment model bases its risk adjustment on inpatient diagnoses and does not capture adequately the risk of caring for a population with functional impairments.

  15. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    Science.gov (United States)

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  16. Pacing in Olympic track races: competitive tactics versus best performance strategy.

    Science.gov (United States)

    Thiel, Christian; Foster, Carl; Banzer, Winfried; De Koning, Jos

    2012-01-01

    The purpose of this study was to describe pacing strategies in the 800 to 10,000-m Olympic finals. We asked 1) if Olympic finals differed from World Records, 2) how variable the pace was, 3) whether runners faced catastrophic events, and 4) for the winning strategy. Publically available data from the Beijing 2008 Olympic Games gathered by four transponder antennae under the 400-m track were analysed to extract descriptors of pacing strategies. Individual pacing patterns of 133 finalists were visualised using speed by distance plots. Six of eight plots differed from the patterns reported for World Records. The coefficient of running speed variation was 3.6-11.4%. In the long distance finals, runners varied their pace every 100 m by a mean 1.6-2.7%. Runners who were 'dropped' from the field achieved a stable running speed and displayed an endspurt. Top contenders used variable pacing strategies to separate themselves from the field. All races were decided during the final lap. Olympic track finalists employ pacing strategies which are different from World Record patterns. The observed micro- and macro-variations of pace may have implications for training programmes. Dropping off the pace of the leading group is an active step, and the result of interactive psychophysiological decision making.

  17. CAMAC interface module for PACE ADC system

    Energy Technology Data Exchange (ETDEWEB)

    Dalton, C G; Mischke, R E [Los Alamos Scientific Lab., N.Mex. (USA); Scott, D T

    1977-03-15

    This report describes a CAMAC module designed to buffer and transfer data from the Tennelec multiplexed ADC system called PACE to a computer. It can be operated in either of two modes: as an eight-deep, first-in-first-out (FIFO) circular buffer, or in channel mode with a single buffer reserved for each PACE channel.

  18. Large animal model of functional tricuspid regurgitation in pacing induced end-stage heart failure.

    Science.gov (United States)

    Malinowski, Marcin; Proudfoot, Alistair G; Langholz, David; Eberhart, Lenora; Brown, Michael; Schubert, Hans; Wodarek, Jeremy; Timek, Tomasz A

    2017-06-01

    Functional tricuspid regurgitation (FTR) is common in patients with advanced heart failure and frequently complicates left ventricular assist device implantation yet remains poorly understood. We set out to establish large animal model of FTR that could serve as a research platform to investigate the pathogenesis of FTR associated with end-stage heart failure. : Through right thoracotomy, ten adult sheep underwent implantation of pacemaker with epicardial LV lead, five sonomicrometry crystals on the right ventricle, and left and right ventricular telemetry pressure sensors during a beating heart off-pump procedure. After 5 ± 1 days of recovery, baseline haemodynamic, echocardiographic and sonomicrometry data were collected. Animals were paced thereafter at a rate of 220-240 beats/min until the development of heart failure and concomitant tricuspid regurgitation. : Three animals died during early recovery period and one during the pacing phase. Six surviving animals were paced for a mean of 14 ± 5 days. Cardiac function was significantly depressed compared to baseline, with LV ejection fraction falling from 69 ± 2% to 22 ± 4% ( P  tricuspid annulus (from 29.5 ± 1.6 to 36.5 ± 4.5 mm; P  = 0.01) and right ventricle (from 21.9 ± 0.2 to 30.3 ± 0.6 mm; P  = 0.03). Sonomicrometry derived contractility of RV free wall was depressed and at least moderate tricuspid insufficiency developed in all animals. : Biventricular dysfunction, tricuspid annular dilatation and significant FTR were observed in our model of ovine tachycardia induced cardiomyopathy. This animal model reflects the clinical situation of end-stage heart failure patients presenting for mechanical support. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Indicators of a poor outcome after temporary pacing in patients with complete atrioventricular block

    International Nuclear Information System (INIS)

    Kazmi, U.; Hyder, S.N.; Sheikh, A.M.

    2013-01-01

    Background: Temporary pace maker (tpm) implantation is an emergency procedure, performed in symptomatic patients with AV block We report our experience of temporary pacing at a tertiary care center. It is the first study of its type from a local center. Objectives: To study the clinical course of patients after tpm implantation and to determine indicators of a poor outcome after tpm implantation. Methods: This was descriptive retrospective study. Data of all tpm procedures performed at Children Hospital from 2006 to 2012 was retrieved. We excluded patients with surgically placed tpm leads. All patients receiving transvenous tpm were included in our study. Results: Total of 12 patients received tpm, 8 were male (66.6%) and 4 were female (33.3%). Median age was 6 years ( range 1.4 -13 year ). Mean weight was 30kg, (range 8.7 - 50kg). All of them presented with complete heart block.One patient each had post diphtheria cardiomyopathy, unknown poisoning. The rest had congenital heart block. The mean period between tpm to ppm implantation was 5 days, (range 1 - 30 days). One patient spontaneously reverted to sinus rhythm(8.3%), 6 had ppm implantation (58.3%), 5 patients expired (33.3%). A low Ejection Fraction was found to be associated with a poor outcome (p<0.01). Variables that were associated with a poor outcome(mortality), were SOB (p<0.015), weak pulses (p<0.015), and hepatomegaly (p<0.01). Conclusion: Low Ejection Fraction and Heart failure is associated with a poor outcome and increased mortality in patients with complete AV block. We suggest that pacing should be considered in patients earlier, before they develop signs or symptoms of cardiac dysfunction. (author)

  20. Perioperative Care of the Patient With the Total Artificial Heart.

    Science.gov (United States)

    Yaung, Jill; Arabia, Francisco A; Nurok, Michael

    2017-05-01

    Advanced heart failure continues to be a leading cause of morbidity and mortality despite improvements in pharmacologic therapy. High demand for cardiac transplantation and shortage of donor organs have led to an increase in the utilization of mechanical circulatory support devices. The total artificial heart is an effective biventricular assist device that may be used as a bridge to transplant and that is being studied for destination therapy. This review discusses the history, indications, and perioperative management of the total artificial heart with emphasis on the postoperative concerns.

  1. Animal personality and pace-of-life syndromes: do fast-exploring fairy-wrens die young?

    Directory of Open Access Journals (Sweden)

    Michelle L Hall

    2015-03-01

    Full Text Available The pace-of-life syndrome (POLS hypothesis for animal personality proposes that variation among individuals in life-history strategies is associated with consistent differences in behavior. We tested predictions of this hypothesis in the superb fairy-wren, Malurus cyaneus, by investigating long-term individual differences in risk-related behaviors (latency to enter a novel artificial environment, exploration, activity and response to mirror image stimulation and survival. We found consistent differences between individuals in these behaviors (adjusted repeatability of exploration of artificial novel environment = 0.37. Individual differences were consistent over several years and bi-variate analyses showed a significant among-individual correlation (‘behavioral syndrome’ between exploration behavior at two life stages (young adult and old adult. Docility at the nestling stage predicted exploration behavior of juveniles. Behavioral traits measured in a risky context were correlated with one another, forming a behavioral syndrome of coping strategies ranging from ‘proactive’ to ‘reactive’. Nestlings that were more active and exploratory in isolation were less docile during handling, while adults that entered the artificial environment fast were more exploratory, active, and aggressive in the artificial environment. Exploration behavior increased within individuals as they aged and when they were in poorer condition, consistent with expectations of more risk-prone behavior with lower residual reproductive value (reduced ‘asset protection’. Risk-related behavior predicted the probability of apparent survival: more exploratory individuals were less likely to be present in the population twelve months later. Our findings suggest that, consistent with the predictions of the POLS hypothesis, individual variation in survival is associated with consistent individual differences in risk-related behavior that are maintained long-term and

  2. Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the Atrial Overdrive Pacing Study.

    Science.gov (United States)

    Kantharia, Bharat K; Freedman, Roger A; Hoekenga, David; Tomassoni, Gery; Worley, Seth; Sorrentino, Robert; Steinhaus, David; Wolkowicz, Joel M; Syed, Zaffer A

    2007-11-01

    Different pacing sites and various algorithms have been utilized to prevent atrial fibrillation (AF) in pacemaker recipients. However, the optimal pacing rate settings have not yet been established. In this randomized, prospective, multicentre, single-blinded, cross over study, rate-adaptive pacing at a high base rate (BR) in patients, age 60 years or above, or a history of paroxysmal AF, who underwent dual-chamber (DDD) pacemaker implantation for standard pacing indications, was evaluated for prevention of AF. In the study cohort of 145 patients implanted with DDD pacemakers with a programmable rest rate (RR) feature, the BR/RR settings were sequentially but randomly adjusted as follows: 60 bpm/Off for the baseline quarter (initial 3 months) and then to either 'A-B-C' or 'C-B-A' settings (A = 70/65 bpm, B = 70/Off, C = 80/65 bpm) for the subsequent quarters each of 3 months duration. Data on automatic mode switch episodes, device diagnostics, and a questionnaire evaluating pacemaker awareness and palpitations were collected. Ninety-nine patients, mean age 77 +/- 10 years, who completed the study protocol and followed for 12 months did not show significant differences in the number of mode switch episodes between any settings used. The percentage of atrial pacing was lower during baseline pacing compared to settings A, B, and C (P < 0.0001). Setting C produced a higher percentage of atrial pacing than A and B (P < 0.01). Although a higher percentage of atrial pacing correlated with a lower incidence of mode switch episodes, there was no statistically significant difference in the number of mode switch episodes between settings A, B, and C. There were no significant differences in the questionnaire scores relating to pacemaker awareness or palpitation. Overdrive single-site pacing in the right atrium achieved by programming analysed settings in the present study did not reduce AF as assessed by mode switch episodes. Additionally, no change in the symptoms of

  3. Effect of right ventricular pacing lead site on left ventricular function in patients with high-grade atrioventricular block: results of the Protect-Pace study.

    Science.gov (United States)

    Kaye, Gerald C; Linker, Nicholas J; Marwick, Thomas H; Pollock, Lucy; Graham, Laura; Pouliot, Erika; Poloniecki, Jan; Gammage, Michael

    2015-04-07

    Chronic right ventricle (RV) apical (RVA) pacing is standard treatment for an atrioventricular (AV) block but may be deleterious to left ventricle (LV) systolic function. Previous clinical studies of non-apical pacing have produced conflicting results. The aim of this randomized, prospective, international, multicentre trial was to compare change in LV ejection fraction (LVEF) between right ventricular apical and high septal (RVHS) pacing over a 2-year study period. We randomized 240 patients (age 74 ± 11 years, 67% male) with a high-grade AV block requiring >90% ventricular pacing and preserved baseline LVEF >50%, to receive pacing at the RVA (n = 120) or RVHS (n = 120). At 2 years, LVEF decreased in both the RVA (57 ± 9 to 55 ± 9%, P = 0.047) and the RVHS groups (56 ± 10 to 54 ± 10%, P = 0.0003). However, there was no significant difference in intra-patient change in LVEF between confirmed RVA (n = 85) and RVHS (n = 83) lead position (P = 0.43). There were no significant differences in heart failure hospitalization, mortality, the burden of atrial fibrillation, or plasma brain natriutetic peptide levels between the two groups. A significantly greater time was required to place the lead in the RVHS position (70 ± 25 vs. 56 ± 24 min, P function requiring a high percentage of ventricular pacing, RVHS pacing does not provide a protective effect on left ventricular function over RVA pacing in the first 2 years. ClinicalTrials.gov number NCT00461734. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  4. Enact legislation supporting residential property assessed clean energy financing (PACE)

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Devashree

    2012-11-15

    Congress should enact legislation that supports residential property assessed clean energy (PACE) programs in the nation’s states and metropolitan areas. Such legislation should require the Federal Housing Finance Agency (FHFA) to allow Fannie Mae and Freddie Mac to purchase residential mortgages with PACE assessments while at the same time providing responsible underwriting standards and a set of benchmarks for residential PACE assessments in order to minimize financial risks to mortgage holders. Congressional support of residential PACE financing will improve energy efficiency, encourage job creation, and foster economic growth in the nation’s state and metropolitan areas.

  5. Characterizing Spatial Dynamics of Bifurcation to Alternans in Isolated Whole Rabbit Hearts Based on Alternate Pacing

    Directory of Open Access Journals (Sweden)

    Kanchan Kulkarni

    2015-01-01

    Full Text Available Sudden cardiac death instigated by ventricular fibrillation (VF is the largest cause of natural death in the USA. Alternans, a beat-to-beat alternation in the action potential duration, has been implicated as being proarrhythmic. The onset of alternans is mediated via a bifurcation, which may occur through either a smooth or a border-collision mechanism. The objective of this study was to characterize the mechanism of bifurcation to alternans based on experiments in isolated whole rabbit hearts. High resolution optical mapping was performed and the electrical activity was recorded from the left ventricle (LV epicardial surface of the heart. Each heart was paced using an “alternate pacing protocol,” where the basic cycle length (BCL was alternatively perturbed by ±δ. Local onset of alternans in the heart, BCLstart, was measured in the absence of perturbations (δ=0 and was defined as the BCL at which 10% of LV exhibited alternans. The influences of perturbation size were investigated at two BCLs: one prior to BCLstart (BCLprior=BCLstart+20 ms and one preceding BCLprior (BCLfar=BCLstart+40 ms. Our results demonstrate significant spatial correlation of the region exhibiting alternans with smooth bifurcation characteristics, indicating that transition to alternans in isolated rabbit hearts occurs predominantly through smooth bifurcation.

  6. Recommendations for pacemaker implantation for the treatment of atrial tachyarrhythmias and resynchronisation therapy for heart failure: A report from the task force on pacemaker indications of the Dutch Working Group on Cardiac Pacing.

    Science.gov (United States)

    van Hemel, N M; Dijkman, B; de Voogt, W G; Beukema, W P; Bosker, H A; de Cock, C C; Jordaens, L J L M; van Gelder, I C; van Gelder, L M; van Mechelen, R; Ruiter, J H; Sedney, M I; Slegers, L C

    2004-01-01

    Today, new pacing algorithms and stimulation methods for the prevention and interruption of atrial tachyarrhythmias can be applied on patients who need bradycardia pacing for conventional reasons. In addition, biventricular pacing as additive treatment for patients with severe congestive heart failure due to ventricular systolic dysfunction and prolonged intraventricular conduction has shown to improve symptoms and reduce hospital admissions. These new pacing technologies and the optimising of the pacing programmes are complex, expensive and time-consuming. Based on many clinical studies the indications for these devices are beginning to emerge. To support the cardiologist's decision-making and to prevent waste of effort and resources, the 'ad hoc committee' has provided preliminary recommendations for implantable devices to treat atrial tachyarrhythmias and to extend the treatment of congestive heart failure respectively.

  7. Pacing a data transfer operation between compute nodes on a parallel computer

    Science.gov (United States)

    Blocksome, Michael A [Rochester, MN

    2011-09-13

    Methods, systems, and products are disclosed for pacing a data transfer between compute nodes on a parallel computer that include: transferring, by an origin compute node, a chunk of an application message to a target compute node; sending, by the origin compute node, a pacing request to a target direct memory access (`DMA`) engine on the target compute node using a remote get DMA operation; determining, by the origin compute node, whether a pacing response to the pacing request has been received from the target DMA engine; and transferring, by the origin compute node, a next chunk of the application message if the pacing response to the pacing request has been received from the target DMA engine.

  8. An ontology-based annotation of cardiac implantable electronic devices to detect therapy changes in a national registry.

    Science.gov (United States)

    Rosier, Arnaud; Mabo, Philippe; Chauvin, Michel; Burgun, Anita

    2015-05-01

    The patient population benefitting from cardiac implantable electronic devices (CIEDs) is increasing. This study introduces a device annotation method that supports the consistent description of the functional attributes of cardiac devices and evaluates how this method can detect device changes from a CIED registry. We designed the Cardiac Device Ontology, an ontology of CIEDs and device functions. We annotated 146 cardiac devices with this ontology and used it to detect therapy changes with respect to atrioventricular pacing, cardiac resynchronization therapy, and defibrillation capability in a French national registry of patients with implants (STIDEFIX). We then analyzed a set of 6905 device replacements from the STIDEFIX registry. Ontology-based identification of therapy changes (upgraded, downgraded, or similar) was accurate (6905 cases) and performed better than straightforward analysis of the registry codes (F-measure 1.00 versus 0.75 to 0.97). This study demonstrates the feasibility and effectiveness of ontology-based functional annotation of devices in the cardiac domain. Such annotation allowed a better description and in-depth analysis of STIDEFIX. This method was useful for the automatic detection of therapy changes and may be reused for analyzing data from other device registries.

  9. Long-term screening for sleep apnoea in paced patients: preliminary assessment of a novel patient management flowchart by using automatic pacemaker indexes and sleep lab polygraphy.

    Science.gov (United States)

    Aimé, Ezio; Rovida, Marina; Contardi, Danilo; Ricci, Cristian; Gaeta, Maddalena; Innocenti, Ester; Cabral Tantchou-Tchoumi, Jacques

    2014-10-01

    The primary aim of this pilot study was to prospectively assess a flowchart to screen and diagnose paced patients (pts) affected by sleep apnoeas, by crosschecking indexes derived from pacemakers (minute ventilation sensor on-board) with Sleep-Lab Polygraphy (PG) outcomes. Secondarily, "smoothed" long-term pacemaker indexes (all the information between two consecutive follow-up visits) have been retrospectively compared vs. standard short-term pacemaker indexes (last 24h) at each follow-up (FU) visit, to test their correlation and diagnostic concordance. Data from long-term FU of 61 paced pts were collected. At each visit, the standard short-term apnoea+hypopnoea (PM_AHI) index was retrieved from the pacemaker memory. Patients showing PM_AHI ≥ 30 at least once during FU were proposed to undergo a PG for diagnostic confirmation. Smoothed pacemaker (PM_SAHI) indexes were calculated by averaging the overall number of apnoeas/hypopnoeas over the period between two FU visits, and retrospectively compared with standard PM_AHI. Data were available from 609 consecutive visits (overall 4.64 ± 1.78 years FU). PM_AHI indexes were positive during FU in 40/61 pts (65.6%); 26/40 pts (65%) accepted to undergo a PG recording; Sleep-Lab confirmed positivity in 22/26 pts (84.6% positive predictive value for PM_AHI). A strong correlation (r=0.73) and a high level of concordance were found between smoothed and standard indexes (multivariate analysis, Cohen's-k and Z-score tests). Pacemaker-derived indexes may help in screening paced pts potentially affected by sleep apnoeas. Long-term "smoothed" apnoea indexes could improve the accuracy of pacemaker screening capability, even though this hypothesis must be prospectively confirmed by larger studies. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  10. PACE: Proactively Secure Accumulo with Cryptographic Enforcement

    Science.gov (United States)

    2017-05-27

    will be replaced with the values from the decrypted destination field. PACE encrypts data using AES and supports the following modes: CTR, CFB, CBC, OFB...2) Searchable Encryption : PACE also support searching for encrypted data. This is done using AES in SIV mode [11] to provide deterministic encryption ...row ”Alphabet”), then the search term is encrypted deterministically, and that term is searched on the server. Because AES does not preserve the

  11. Factors explaining voluntary participation in PACE-Vaquita

    OpenAIRE

    Sara Avila

    2011-01-01

    Vaquita marina, a small species of porpoise endemic to the Northern Gulf of California in Mexico, is the world’s most endangered cetacean species. With the purpose of preserving vaquita, the Mexican government launched PACE-Vaquita in 2008. This voluntary program offers an innovative schedule of compensations: as in a payment for conservation program, PACE-Vaquita compensates for temporary reductions in fishing reductions in fishing effort; as in a program to accelerate technology adoption,PA...

  12. Artificial intelligence in radiology.

    Science.gov (United States)

    Hosny, Ahmed; Parmar, Chintan; Quackenbush, John; Schwartz, Lawrence H; Aerts, Hugo J W L

    2018-05-17

    Artificial intelligence (AI) algorithms, particularly deep learning, have demonstrated remarkable progress in image-recognition tasks. Methods ranging from convolutional neural networks to variational autoencoders have found myriad applications in the medical image analysis field, propelling it forward at a rapid pace. Historically, in radiology practice, trained physicians visually assessed medical images for the detection, characterization and monitoring of diseases. AI methods excel at automatically recognizing complex patterns in imaging data and providing quantitative, rather than qualitative, assessments of radiographic characteristics. In this Opinion article, we establish a general understanding of AI methods, particularly those pertaining to image-based tasks. We explore how these methods could impact multiple facets of radiology, with a general focus on applications in oncology, and demonstrate ways in which these methods are advancing the field. Finally, we discuss the challenges facing clinical implementation and provide our perspective on how the domain could be advanced.

  13. A portable cadmium telluride multidetector probe for cardiac function monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Arntz, Y.; Chambron, J.; Dumitresco, B.; Eclancher, B. E-mail: eclan@alsace.u-strasbg.fr; Prat, V

    1999-06-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) which well depicted the filling and ejection of the cardiac beats, allowing to compare the clinically relevant parameters of the cardiac performance, proportional variables of the stroke volume (SV), ejection fraction (EF) and ventricular flow-rate with the known absolute values programmed on the model. The portable system is now in operation for clinical assessment of cardiac patients.

  14. A portable cadmium telluride multidetector probe for cardiac function monitoring

    International Nuclear Information System (INIS)

    Arntz, Y.; Chambron, J.; Dumitresco, B.; Eclancher, B.; Prat, V.

    1999-01-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) which well depicted the filling and ejection of the cardiac beats, allowing to compare the clinically relevant parameters of the cardiac performance, proportional variables of the stroke volume (SV), ejection fraction (EF) and ventricular flow-rate with the known absolute values programmed on the model. The portable system is now in operation for clinical assessment of cardiac patients

  15. EFFECT OF ADAPTIVE PACED CARDIOLOCOMOTOR SYNCHRONIZATION DURING RUNNING: A PRELIMINARY STUDY

    Directory of Open Access Journals (Sweden)

    Bill Phillips

    2013-09-01

    Full Text Available Cardiolocomotor synchronization (CLS has been well established for individuals engaged in rhythmic activity, such as walking, running, or cycling. When frequency of the activity is at or near the heart rate, entrainment occurs. CLS has been shown in many cases to improve the efficiency of locomotor activity, improving stroke volume, reducing blood pressure variability, and lowering the oxygen uptake (VO2. Instead of a 1:1 frequency ratio of activity to heart rate, an investigation was performed to determine if different harmonic coupling at other simple integer ratios (e.g. 1:2, 2:3, 3:2 could achieve any performance benefits. CLS was ensured by pacing the stride rate according to the measured heartbeat (i.e., adaptive paced CLS, or forced CLS. An algorithm was designed that determined the simplest ratio (lowest denominator that, when multiplied by the heart rate will fall within an individualized, predetermined comfortable pacing range for the user. The algorithm was implemented on an iPhone 4, which generated a 'tick-tock' sound through the iPhone's headphones. A sham-controlled crossover study was performed with 15 volunteers of various fitness levels. Subjects ran a 3 mile (4.83 km simulated training run at their normal pace on two consecutive days (randomized one adaptive pacing, one sham. Adaptive pacing resulted in faster runs run times, with subjects running an average of 26:03 ± 3:23 for adaptive pacing and 26:38 ± 3:31 for sham (F = 5.46, p < 0.05. The increase in heart rate from the start of the race as estimated by an exponential time constant was significantly longer during adaptive pacing, τ = 0.99 ± 0.30, compared to sham, τ = 1.53 ± 0.34 (t = -6.62, p < 0.01. Eighty-seven percent of runners found it easy to adjust their stride length to match the pacing signal with seventy-nine percent reporting that pacing helped their performance. These results suggest that adaptive paced CLS may have a beneficial effect on running

  16. Kinematic hand parameters in front crawl at different paces of swimming.

    Science.gov (United States)

    Samson, Mathias; Monnet, Tony; Bernard, Anthony; Lacouture, Patrick; David, Laurent

    2015-11-05

    The aim of this study was to investigate the evolution of kinematic hand parameters (sweepback angle, angle of attack, velocity, acceleration and orientation of the hand relative to the absolute coordinate system) throughout an aquatic stroke and to study the possible modifications caused by a variation of the swimming pace. Seventeen competitive swimmers swam at long distance, middle distance and sprint paces. Parameters were calculated from the trajectory of seven markers on the hand measured with an optoelectronic system. Results showed that kinematic hand parameters evolve differently depending on the pace. Angle of attack, sweepback angle, acceleration and orientation of the hand do not vary significantly. The velocity of the hand increases when the pace increases, but only during the less propulsive phases (entry and stretch and downsweep to catch). The more the pace increases and the more the absolute durations of the entry and stretch and downsweep to catch phases decrease. Absolute durations of the insweep and upsweep phases remain constant. During these phases, the propulsive hand forces calculated do not vary significantly when the pace increases. The increase of swimming pace is then explained by the swimmer's capacity to maintain propulsive phases rather than increasing the force generation within each cycle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Manolis, Antonis S.; Mont, Lluis; Pürerfellner, Helmut; Santini, Massimo; Inama, Giuseppe; Serra, Paolo; de Sousa, João; Botto, Giovanni Luca; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2014-01-01

    Aims Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). Methods and results In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 ± 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55–0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77–1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52–0.85, P MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. ClinicalTrials.gov Identifier NCT00262119. PMID:24771721

  18. Pacing and Self-regulation: Important Skills for Talent Development in Endurance Sports.

    Science.gov (United States)

    Elferink-Gemser, Marije T; Hettinga, Florentina J

    2017-07-01

    Pacing has been characterized as a multifaceted goal-directed process of decision making in which athletes need to decide how and when to invest their energy during the race, a process essential for optimal performance. Both physiological and psychological characteristics associated with adequate pacing and performance are known to develop with age. Consequently, the multifaceted skill of pacing might be under construction throughout adolescence, as well. Therefore, the authors propose that the complex skill of pacing is a potential important performance characteristic for talented youth athletes that needs to be developed throughout adolescence. To explore whether pacing is a marker for talent and how talented athletes develop this skill in middle-distance and endurance sports, they aim to bring together literature on pacing and literature on talent development and self-regulation of learning. Subsequently, by applying the cyclical process of self-regulation to pacing, they propose a practical model for the development of performance in endurance sports in youth athletes. Not only is self-regulation essential throughout the process of reaching the long-term goal of athletic excellence, but it also seems crucial for the development of pacing skills within a race and the development of a refined performance template based on previous experiences. Coaches and trainers are advised to incorporate pacing as a performance characteristic in their talent-development programs by stimulating their athletes to reflect, plan, monitor, and evaluate their races on a regular basis to build performance templates and, as such, improve their performance.

  19. Differential effects of film on preschool children's behaviour dependent on editing pace.

    Science.gov (United States)

    Kostyrka-Allchorne, Katarzyna; Cooper, Nicholas R; Gossmann, Anna Maria; Barber, Katy J; Simpson, Andrew

    2017-05-01

    Evidence on how the pace of television and film editing affects children's behaviour and attention is inconclusive. We examined whether a fast-paced film affected how preschool-aged children interacted with toys. The study comprised 70 children (36 girls) aged two to four-and-a-half years who attended preschools in Essex, United Kingdom. The children were paired up and tested with either a fast- or a slow-paced film of a narrator reading a children's story. The fast-paced version had 102 camera cuts and 16 still images, and the slow-paced version had 22 camera cuts and four still images. Each dyad took part in two video-recorded free-play sessions, before and after they watched one of the specially edited four-minute films. The number of toys the children played with before and after the film sessions was recorded. Before they watched the films, the children's behaviour did not differ between the groups. However, after watching the film, the children in the fast-paced group shifted their attention between toys more frequently than the children who watched the slow-paced film. Even a brief exposure to differently paced films had an immediate effect on how the children interacted with their toys. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  20. DEGRO/DGK guideline for radiotherapy in patients with cardiac implantable electronic devices

    International Nuclear Information System (INIS)

    Gauter-Fleckenstein, Benjamin; Steil, Volker; Wenz, Frederik; Israel, Carsten W.; Dorenkamp, Marc; Dunst, Juergen; Roser, Mattias; Schimpf, Rainer; Schaefer, Joerg; Hoeller, Ulrike

    2015-01-01

    An increasing number of patients undergoing radiotherapy (RT) have cardiac implantable electronic devices [CIEDs, cardiac pacemakers (PMs) and implanted cardioverters/defibrillators (ICDs)]. Ionizing radiation can cause latent and permanent damage to CIEDs, which may result in loss of function in patients with asystole or ventricular fibrillation. Reviewing the current literature, the interdisciplinary German guideline (DEGRO/DGK) was developed reflecting patient risk according to type of CIED, cardiac condition, and estimated radiation dose to the CIED. Planning for RT should consider the CIED specifications as well as patient-related characteristics (pacing-dependent, previous ventricular tachycardia/fibrillation). Antitachyarrhythmia therapy should be suspended in patients with ICDs, who should be under electrocardiographic monitoring with an external defibrillator on stand-by. The beam energy should be limited to 6 (to 10) MV CIEDs should never be located in the beam, and the cumulative scatter radiation dose should be limited to 2 Gy. Personnel must be able to respond adequately in the case of a cardiac emergency and initiate basic life support, while an emergency team capable of advanced life support should be available within 5 min. CIEDs need to be interrogated 1, 3, and 6 months after the last RT due to the risk of latent damage. (orig.) [de

  1. Effects of simultaneous and optimized sequential cardiac resynchronization therapy on myocardial oxidative metabolism and efficiency.

    Science.gov (United States)

    Christenson, Stuart D; Chareonthaitawee, Panithaya; Burnes, John E; Hill, Michael R S; Kemp, Brad J; Khandheria, Bijoy K; Hayes, David L; Gibbons, Raymond J

    2008-02-01

    Cardiac resynchronization therapy (CRT) can improve left ventricular (LV) hemodynamics and function. Recent data suggest the energy cost of such improvement is favorable. The effects of sequential CRT on myocardial oxidative metabolism (MVO(2)) and efficiency have not been previously assessed. Eight patients with NYHA class III heart failure were studied 196 +/- 180 days after CRT implant. Dynamic [(11)C]acetate positron emission tomography (PET) and echocardiography were performed after 1 hour of: 1) AAI pacing, 2) simultaneous CRT, and 3) sequential CRT. MVO(2) was calculated using the monoexponential clearance rate of [(11)C]acetate (k(mono)). Myocardial efficiency was expressed in terms of the work metabolic index (WMI). P values represent overall significance from repeated measures analysis. Global LV and right ventricular (RV) MVO(2) were not significantly different between pacing modes, but the septal/lateral MVO(2) ratio differed significantly with the change in pacing mode (AAI pacing = 0.696 +/- 0.094 min(-1), simultaneous CRT = 0.975 +/- 0.143 min(-1), and sequential CRT = 0.938 +/- 0.189 min(-1); overall P = 0.001). Stroke volume index (SVI) (AAI pacing = 26.7 +/- 10.4 mL/m(2), simultaneous CRT = 30.6 +/- 11.2 mL/m(2), sequential CRT = 33.5 +/- 12.2 mL/m(2); overall P simultaneous CRT = 4.29 +/- 1.72 mmHg*mL/m(2)*10(6), sequential CRT = 4.79 +/- 1.92 mmHg*mL/m(2)*10(6); overall P = 0.002) also differed between pacing modes. Compared with simultaneous CRT, additional changes in septal/lateral MVO(2), SVI, and WMI with sequential CRT were not statistically significant on post hoc analysis. In this small selected population, CRT increases LV SVI without increasing MVO(2), resulting in improved myocardial efficiency. Additional improvements in LV work, oxidative metabolism, and efficiency from simultaneous to sequential CRT were not significant.

  2. Pharmacological treatment of cardiac glycoside poisoning.

    Science.gov (United States)

    Roberts, Darren M; Gallapatthy, Gamini; Dunuwille, Asunga; Chan, Betty S

    2016-03-01

    Cardiac glycosides are an important cause of poisoning, reflecting their widespread clinical usage and presence in natural sources. Poisoning can manifest as varying degrees of toxicity. Predominant clinical features include gastrointestinal signs, bradycardia and heart block. Death occurs from ventricular fibrillation or tachycardia. A wide range of treatments have been used, the more common including activated charcoal, atropine, β-adrenoceptor agonists, temporary pacing, anti-digoxin Fab and magnesium, and more novel agents include fructose-1,6-diphosphate (clinical trial in progress) and anticalin. However, even in the case of those treatments that have been in use for decades, there is debate regarding their efficacy, the indications and dosage that optimizes outcomes. This contributes to variability in use across the world. Another factor influencing usage is access. Barriers to access include the requirement for transfer to a specialized centre (for example, to receive temporary pacing) or financial resources (for example, anti-digoxin Fab in resource poor countries). Recent data suggest that existing methods for calculating the dose of anti-digoxin Fab in digoxin poisoning overstate the dose required, and that its efficacy may be minimal in patients with chronic digoxin poisoning. Cheaper and effective medicines are required, in particular for the treatment of yellow oleander poisoning which is problematic in resource poor countries. © 2015 The British Pharmacological Society.

  3. To pace or not to pace: a pilot study of four- and five-gaited Icelandic horses homozygous for the DMRT3 'Gait Keeper' mutation.

    Science.gov (United States)

    Jäderkvist Fegraeus, K; Hirschberg, I; Árnason, T; Andersson, L; Velie, B D; Andersson, L S; Lindgren, G

    2017-12-01

    The Icelandic horse is a breed known mainly for its ability to perform the ambling four-beat gait 'tölt' and the lateral two-beat gait pace. The natural ability of the breed to perform these alternative gaits is highly desired by breeders. Therefore, the discovery that a nonsense mutation (C>A) in the DMRT3 gene was the main genetic factor for horses' ability to perform gaits in addition to walk, trot and canter was of great interest. Although several studies have demonstrated that homozygosity for the DMRT3 mutation is important for the ability to pace, only about 70% of the homozygous mutant (AA) Icelandic horses are reported to pace. The aim of the study was to genetically compare four- and five-gaited (i.e. horses with and without the ability to pace) AA Icelandic horses by performing a genome-wide association (GWA) analysis. All horses (n = 55) were genotyped on the 670K Axiom Equine Genotyping Array, and a GWA analysis was performed using the genabel package in r. No SNP demonstrated genome-wide significance, implying that the ability to pace goes beyond the presence of a single gene variant. Despite its limitations, the current study provides additional information regarding the genetic complexity of pacing ability in horses. However, to fully understand the genetic differences between four- and five-gaited AA horses, additional studies with larger sample materials and consistent phenotyping are needed. © 2017 Stichting International Foundation for Animal Genetics.

  4. Clinically oriented device programming in bradycardia patients: part 2 (atrioventricular blocks and neurally mediated syncope). Proposals from AIAC (Italian Association of Arrhythmology and Cardiac Pacing).

    Science.gov (United States)

    Palmisano, Pietro; Ziacchi, Matteo; Biffi, Mauro; Ricci, Renato P; Landolina, Maurizio; Zoni-Berisso, Massimo; Occhetta, Eraldo; Maglia, Giampiero; Botto, Gianluca; Padeletti, Luigi; Boriani, Giuseppe

    2018-04-01

    : The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features. In part 2, criteria for pacemaker choice and programming in atrioventricular blocks and neurally mediate syncope are proposed. The atrioventricular blocks can be paroxysmal or persistent, isolated or associated with sinus node disease. Neurally mediated syncope can be related to carotid sinus syndrome or cardioinhibitory vasovagal syncope. In sinus rhythm, with persistent atrioventricular block, we considered appropriate the activation of mode-switch algorithms, and algorithms for auto-adaptive management of the ventricular pacing output. If the atrioventricular block is paroxysmal, in addition to algorithms mentioned above, algorithms to maximize intrinsic atrioventricular conduction should be activated. When sinus node disease is associated with atrioventricular block, the activation of rate-responsive function in patients with chronotropic incompetence is appropriate. In permanent atrial fibrillation with atrioventricular block, algorithms for auto-adaptive management of the ventricular pacing output should be activated. If the atrioventricular block is persistent, the activation of rate-responsive function is appropriate. In carotid sinus syndrome, adequate rate hysteresis should be programmed. In vasovagal syncope, specialized sensing and pacing algorithms designed for reflex syncope prevention should be activated.

  5. The solarPACES strategy for the solar thermal breakthrough

    International Nuclear Information System (INIS)

    Burch, G.D.; Grasse, W.

    1997-01-01

    IEA(International Energy Agency)/SolarPACES(Solar Power and Chemical Energy systems)represents a world wide coalition for information sharing and collaboration on applications of concentrated solar energy. The current SolarPACES community has built up solar thermal system know-how over 15 years, is operating the three main solar test centres in the world. Its main activities are in the following four fields: solar thermal electric power systems, solar chemistry, solar technology and advanced applications and non-technical activities. The article presents the talk on the strategy of solarPACES given at the International Workshop on applied solar energy held in Tashkent(Uzbekistan) in June 1997. (A.A.D.)

  6. METODE FUTURE PACING HYPNOTHERAPY UNTUK MENURUNKAN TINGKAT KECEMASAN PADA MAHASISWA BARU

    Directory of Open Access Journals (Sweden)

    Zahro Varisna Rohmadani

    2017-09-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui efektivitas metode future pacing hypnotherapy dalam menurunkan tingkat kecemasan pada mahasiswa baru. Subjek penelitian adalah 20 mahasiswa/i baru, 10 mahasiswa di kelompok eksperimen dan 10 mahasiswa di kelompok kontrol. Peserta mendapatkan penanganan untuk penurunan kecemasan dengan metode berupa future pacing hypnotherapy. Metode analisis data yang digunakan adalah statistik nonparametrik teknik Wilcoxon Signed Rank Test untuk menguji perbedaan skor cemas kelompok subjek saat pretest dan posttest serta Mann Whitney U untuk melihat perbedaan penurunan kecemasan pada kelompok eksperimen dan kelompok kontrol. Hasil Wilcoxon Signed Rank Test menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,012. Sedangkan hasil Mann Whitney U menunjukkan bahwa future pacing hypnotherapy efektif dalam menurunkan kecemasan dengan p=0,003 dan kelompok eksperimen mengalami penurunan kecemasan yang lebih besar dengan mean rank = 14,25.Kata kunci : future pacing hypnotherapy, kecemasan, mahasiswa baru

  7. Effect of Smaller Left Ventricular Capture Threshold Safety Margins to Improve Device Longevity in Recipients of Cardiac Resynchronization-Defibrillation Therapy.

    Science.gov (United States)

    Steinhaus, Daniel A; Waks, Jonathan W; Collins, Robert; Kleckner, Karen; Kramer, Daniel B; Zimetbaum, Peter J

    2015-07-01

    Device longevity in cardiac resynchronization therapy (CRT) is affected by the pacing capture threshold (PCT) and programmed pacing amplitude of the left ventricular (LV) pacing lead. The aims of this study were to evaluate the stability of LV pacing thresholds in a nationwide sample of CRT defibrillator recipients and to determine potential longevity improvements associated with a decrease in the LV safety margin while maintaining effective delivery of CRT. CRT defibrillator patients in the Medtronic CareLink database were eligible for inclusion. LV PCT stability was evaluated using ≥2 measurements over a 14-day period. Separately, a random sample of 7,250 patients with programmed right atrial and right ventricular amplitudes ≤2.5 V, LV thresholds ≤ 2.5 V, and LV pacing ≥90% were evaluated to estimate theoretical battery longevity improvement using LV safety margins of 0.5 and 1.5 V. Threshold stability analysis in 43,256 patients demonstrated LV PCT stability of 1 V had the greatest increases in battery life (mean increase 0.86 years, 95% confidence interval 0.85 to 0.87). In conclusion, nearly all CRT defibrillator patients had LV PCT stability <1.0 V. Decreasing the LV safety margin from 1.5 to 0.5 V provided consistent delivery of CRT for most patients and significantly improved battery longevity. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Cardiac e-learning: Development of a web-based implantable cardioverter defibrillator educational system.

    Science.gov (United States)

    Hickey, Kathleen T; Johnson, Mary P; Biviano, Angelo; Aboelela, Sally; Thomas, Tami; Bakken, Suzanne; Garan, Hasan; Zimmerman, John L; Whang, William

    2011-04-01

    The objective of this study was to design a Web-based implantable cardioverter defibrillator (ICD) module that would allow greater access to learning which could occur at an individual's convenience outside the fast-paced clinical environment. A Web-based ICD software educational program was developed to provide general knowledge of the function of the ICD and the interpretation of the stored electrocardiograms. This learning tool could be accessed at any time via the Columbia University Internet server, using a unique, password protected login. A series of basic and advanced ICD terms were presented using actual ICD screenshots and videos that simulated scenarios the practitioner would most commonly encounter in the fast-paced clinical setting. To determine the usefulness of the site and improve the module, practitioners were asked to complete a brief (less than 5 min) online survey at the end of the module. Twenty-six practitioners have logged into our Web site: 20 nurses/nurse practitioners, four cardiac fellows, and two other practitioners. The majority of respondents rated the program as easy to use and useful. The success of this module has led to it becoming part of the training for student nurse practitioners before a clinical electrophysiology rotation, and the module is accessed by our cardiac entry level fellows before a rotation in the intensive care unit or electrophysiology service. Remote electronic arrhythmia learning is a successful example of the melding of technology and education to enhance clinical learning.

  9. Self-Paced Instruction: Hello, Education

    Science.gov (United States)

    Leuba, Richard J.; Flammer, Gordon H.

    1975-01-01

    Answers criticisms of self-paced instruction (SPI) by citing advantages of SPI over lecture methods. Concludes that criticisms of SPI are useful since they indicate in which areas further research should be conducted to improve this method of instruction. (MLH)

  10. Pace: an advanced structure for handling multi-technique NDT

    International Nuclear Information System (INIS)

    Mayos, M.; Guisnel, F.

    1995-08-01

    The growing extent and complexity of NDT data analysis has reached a stage where dedicated systems are required. In the context of a European research program, EDF participated from 1992 to 1994 in one of the first international projects in this field, TRAPPIST and, in 1993, began developing An application for the electricity generating industry, giving rise to the PACE project. The prime objective specially targets the French electricity generating industry, where PACE was to be the reference system for analysis of NDE data concerning EdF power plants. The second objective is to promote the adoption of PACE by other industrial sectors and other countries. The analysis of needs shows that the required system must be designed to analyze data from widely different sources. The PACE entry point consequently has to be a standard format compatible with geometrical data as well as those provided by NDT. The TRAPPIST format constitutes the first version of this standard and is the first step towards European standardization in this respect. Consideration of the different user modes defined for PACE led to the design of a 2-part user structure comprising a database management system (Ingres/Windows 4GL) and a display/processing tool (AVS), also usable to construct analysis scenarios. The structure of PACE is defined nd seems well suited to industrial requirements, but before it is possible to proceed further towards its adoption for actual power plant inspections, it has to be validated on a more realistic application, the eddy current and ultrasonic testing of a full-scale T-joint. This is already under way, whilst work on format standardization and industrialization preparatory procedures are proceeding in parallel. (authors). 4 refs., 6 figs

  11. The role of mitochondria for the regulation of cardiac alternans

    Directory of Open Access Journals (Sweden)

    Stela M Florea

    2010-11-01

    Full Text Available Electromechanical and Ca alternans is a beat-to-beat alternation of action potential duration, contraction strength and Ca transient amplitude observed in cardiac myocytes at regular stimulation frequency. Ca alternans is a multifactorial process that is causally linked to cardiac arrhythmias. At the cellular level, conditions that increase fractional release from the sarcoplasmic reticulum or reduce diastolic Ca sequestration favor the occurrence of alternans. Mitochondria play a significant role in cardiac excitation-contraction coupling and Ca signaling by providing the energy for contraction and ATP-dependent processes and possibly by serving as Ca buffering organelles. Here we tested the hypothesis that impairment of mitochondrial function generates conditions that favor the occurrence of Ca alternans. Alternans were elicited by electrical pacing (>1 Hz in single cat atrial myocytes and intracellular Ca ([Ca]i was measured with the fluorescent Ca indicator Indo-1. The degree of alternans was quantified as the alternans ratio (AR=1-S/L, where S/L is the ratio of the small to the large amplitude of a pair of alternating Ca transients. Dissipation of mitochondrial membrane potential (with FCCP as well as inhibition of mitochondrial F1/F0-ATP synthase (oligomycin, electrontransport chain (rotenone, antimycin, CN-, Ca-dependent dehydrogenases and mitochondrial Ca uptake or extrusion, all enhanced AR and lowered the threshold for the occurrence of Ca alternans. The data indicate that impairment of mitochondrial function adversely affects cardiac Ca cycling leading to proarrhythmic Ca alternans.

  12. Will the Conscious-Subconscious Pacing Quagmire Help Elucidate the Mechanisms of Self-Paced Exercise? New Opportunities in Dual Process Theory and Process Tracing Methods.

    Science.gov (United States)

    Micklewright, Dominic; Kegerreis, Sue; Raglin, John; Hettinga, Florentina

    2017-07-01

    The extent to which athletic pacing decisions are made consciously or subconsciously is a prevailing issue. In this article we discuss why the one-dimensional conscious-subconscious debate that has reigned in the pacing literature has suppressed our understanding of the multidimensional processes that occur in pacing decisions. How do we make our decisions in real-life competitive situations? What information do we use and how do we respond to opponents? These are questions that need to be explored and better understood, using smartly designed experiments. The paper provides clarity about key conscious, preconscious, subconscious and unconscious concepts, terms that have previously been used in conflicting and confusing ways. The potential of dual process theory in articulating multidimensional aspects of intuitive and deliberative decision-making processes is discussed in the context of athletic pacing along with associated process-tracing research methods. In attempting to refine pacing models and improve training strategies and psychological skills for athletes, the dual-process framework could be used to gain a clearer understanding of (1) the situational conditions for which either intuitive or deliberative decisions are optimal; (2) how intuitive and deliberative decisions are biased by things such as perception, emotion and experience; and (3) the underlying cognitive mechanisms such as memory, attention allocation, problem solving and hypothetical thought.

  13. Efficiency of timing delays and electrode positions in optimization of biventricular pacing: a simulation study.

    Science.gov (United States)

    Miri, Raz; Graf, Iulia M; Dössel, Olaf

    2009-11-01

    Electrode positions and timing delays influence the efficacy of biventricular pacing (BVP). Accordingly, this study focuses on BVP optimization, using a detailed 3-D electrophysiological model of the human heart, which is adapted to patient-specific anatomy and pathophysiology. The research is effectuated on ten heart models with left bundle branch block and myocardial infarction derived from magnetic resonance and computed tomography data. Cardiac electrical activity is simulated with the ten Tusscher cell model and adaptive cellular automaton at physiological and pathological conduction levels. The optimization methods are based on a comparison between the electrical response of the healthy and diseased heart models, measured in terms of root mean square error (E(RMS)) of the excitation front and the QRS duration error (E(QRS)). Intra- and intermethod associations of the pacing electrodes and timing delays variables were analyzed with statistical methods, i.e., t -test for dependent data, one-way analysis of variance for electrode pairs, and Pearson model for equivalent parameters from the two optimization methods. The results indicate that lateral the left ventricle and the upper or middle septal area are frequently (60% of cases) the optimal positions of the left and right electrodes, respectively. Statistical analysis proves that the two optimization methods are in good agreement. In conclusion, a noninvasive preoperative BVP optimization strategy based on computer simulations can be used to identify the most beneficial patient-specific electrode configuration and timing delays.

  14. Pacing in swimming - variability and effects of manipulations

    OpenAIRE

    Skorski, Sabrina

    2015-01-01

    Introduction: In any athletic event, the ability to appropriately distribute energy, is essential to prevent premature fatigue prior to the completion of the event. In sport science literature this is termed ‘pacing’. Within the past decade, research aiming to better understand the underlying mechanisms influencing the selection of an athlete’s pacing during exercise has dramatically increased. It is suggested that pacing is a combination of anticipation, knowledge of the end-point, prior exp...

  15. Reduced capacity of cardiac efferent sympathetic neurons to release noradrenaline and modify cardiac function in tachycardia-induced canine heart failure.

    Science.gov (United States)

    Cardinal, R; Nadeau, R; Laurent, C; Boudreau, G; Armour, J A

    1996-09-01

    To investigate the capacity of efferent sympathetic neurons to modulate the failing heart, stellate ganglion stimulation was performed in dogs with biventricular heart failure induced by rapid ventricular pacing (240 beats/min) for 4-6 weeks. Less noradrenaline was released from cardiac myoneural junctions into coronary sinus blood in response to left stellate ganglion stimulation in anesthetized failing heart preparations (582 pg/mL, lower and upper 95% confidence intervals of 288 and 1174 pg/mL, n = 19) compared with healthy heart preparations (6391 pg/mL, 95% confidence intervals of 4180 and 9770 pg/mL, n = 14; p < 0.001). There was substantial adrenaline extraction by failing hearts (49 +/- 6%), although it was slightly lower than in healthy heart preparations (65 +/- 9%, p = 0.055). In contrast with healthy heart preparations, no net release of adrenaline occurred during stellate ganglion stimulation in any of the failing heart preparations, and ventricular tissue levels of adrenaline fell below the sensitivity limit of the HPLC technique. In failing heart preparations, maximal electrical stimulation of right or left stellate ganglia resulted in minimal augmentation of left ventricular intramyocardial (17%) and chamber (12%) systolic pressures. These indices were augmented by 145 and 97%, respectively, following exogenous noradrenaline administration. Thus, the cardiac efferent sympathetic neurons' reduced capacity to release noradrenaline and modify cardiac function can contribute to reduction of sympathetic support to the failing heart.

  16. A cardiac implantable device infection by Raoultella planticola in an immunocompromized patient.

    Science.gov (United States)

    Adjodah, Chandra; D'Ivernois, Chistophe; Leyssene, David; Berneau, Jean-Baptiste; Hemery, Yann

    2017-02-01

    Introduction. Infection of cardiac implantable electronic devices is a severe condition associated with high mortality, particularly in patients who are dependent upon heart-pacing devices. Staphylococci are found in 70 % of reported cases. Case presentation. We report the case of a cardiac-pacemaker infection in a 79-year-old man, cumulating a history of rheumatoid arthritis treated by corticosteroids and methotrexate by a recently identified micro-organism: Raoultella planticola . He presented local signs of infection on his VVI pacemaker implantation site and underwent urgent pocket device replacement under cefamandole antibioprophylaxis. On incision thick pus oozed out. It was necessary to perform a complete hardware extraction comprising the pulse generator and the ancient lead. Pus was inoculated into aerobic and anaerobic culture vials and Gram staining unveiled Gram-negative rods. Microbiology analysis identified the organism as R. planticola. A new pacing device was inserted on the contrlateral pectoral region. Ciprofloxacin enabled full recovery. A literature review concerning this pathogen revealed that it is involved in severe infections such as bloodstream infections, peritonitis, cellulitis, pneumonia and lung abscesses, and urinary tract infections. In these case reports, underlying co-morbidities were identified such as solid active neoplasia, recent chemotherapy, corticosteroids, solid-organ-recipient patients and recent open surgery. Conclusion. R. planticola is a serious emerging pathogen and contributes to the burden of various infectious conditions. Its pathogenicity and occurrence should be known by clinicians and a high level of awareness is necessary to precisely identify it provide the correct antibiotic regimen.

  17. Successful heart transplant after 1374 days living with a total artificial heart.

    Science.gov (United States)

    Gerosa, Gino; Gallo, Michele; Bottio, Tomaso; Tarzia, Vincenzo

    2016-04-01

    The CardioWest Total Artificial Heart (CW-TAH) has been approved as a temporary device for bridge to cardiac transplantation and is under investigation for destination therapy by US Food and Drug Administration (FDA). We herein report the longest worldwide survival out of hospital (1374 days) of a patient supported with Cardio West Total Artificial Heart (CW-TAH). This experience is intended as a proof of concept of using CW-TAH as the destination therapy in patients with biventricular failure. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. PACE3 - front-end chip for the CMS Preshower

    CERN Multimedia

    Aspel, Paul

    2003-01-01

    This is PACE3 which is the front-end chip for the CMS Preshower. In fact PACE3 is the combination of two ASICs called Delta3 and PACEAM3. Delta3 is on the left and PACEAM3 is on the right. The two ASICs are bonded together and then packaged within a single 196 pin fpBGA package.

  19. A low-power bidirectional telemetry device with a near-field charging feature for a cardiac microstimulator.

    Science.gov (United States)

    Shuenn-Yuh Lee; Chih-Jen Cheng; Ming-Chun Liang

    2011-08-01

    In this paper, wireless telemetry using the near-field coupling technique with round-wire coils for an implanted cardiac microstimulator is presented. The proposed system possesses an external powering amplifier and an internal bidirectional microstimulator. The energy of the microstimulator is provided by a rectifier that can efficiently charge a rechargeable device. A fully integrated regulator and a charge pump circuit are included to generate a stable, low-voltage, and high-potential supply voltage, respectively. A miniature digital processor includes a phase-shift-keying (PSK) demodulator to decode the transmission data and a self-protective system controller to operate the entire system. To acquire the cardiac signal, a low-voltage and low-power monitoring analog front end (MAFE) performs immediate threshold detection and data conversion. In addition, the pacing circuit, which consists of a pulse generator (PG) and its digital-to-analog (D/A) controller, is responsible for stimulating heart tissue. The chip was fabricated by Taiwan Semiconductor Manufacturing Company (TSMC) with 0.35-μm complementary metal-oxide semiconductor technology to perform the monitoring and pacing functions with inductively powered communication. Using a model with lead and heart tissue on measurement, a -5-V pulse at a stimulating frequency of 60 beats per minute (bpm) is delivered while only consuming 31.5 μW of power.

  20. A human factors experiment on the event-paced control tasks issue

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Chul; Park, Jae Chang; Oh, In Seok; Lee, Jung Woon; Lee, Ki Young; Park, Jong Kyun [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-03-01

    KEPRI(Korea Electric Power Research Institute) requires human factors validation tests according to the progress of the KNGR MMI design. This report describes the experimental results of an human factors validation issue, Event-Paced Control Tasks issue. The Event-Paced Control Task issue is to test that the designed MMI shall support operators in performing control tasks in pace with the plant dynamics. Task completion time and successful execution are defined as performance measures on the issue. Through an experiment on the issue with 3 scenarios and 5 subjects, we report that the variation of task completion time between subjects has a narrow band for each scenarios, however two among the total 15 experimental runs result in the failure that subject does not reach to the predefined operational goal. Incorrect operational strategy, insufficient training, and MMI design discrepancies are inferred as the causes of the failures. However these experimental results don't indicate the close of the Event-Paced Control Tasks issue. The validation test results under the experimental environment composed of the partial MMI representations, an unstable simulator, and insufficient subject training, are significant in the limited conditions. Thus, for the purpose of the complete issue close, the validation test on the Event-Paced Control Tasks issue should be repeatedly carried out in pace with the performance improvement of the experimental environment. 13 figs., 4 tabs. (Author)

  1. Science Unit Plans. PACE '94.

    Science.gov (United States)

    Schoon, Kenneth J., Ed.; Wiles, Clyde A., Ed.

    This booklet contains mathematics unit plans for Biology, Chemistry, and Physical Science developed by PACE (Promoting Academic Excellence In Mathematics, Science & Technology for Workers of the 21st Century). Each unit plan contains suggested timing, objectives, skills to be acquired, workplace relationships, learning activities with suggested…

  2. Does a run/walk strategy decrease cardiac stress during a marathon in non-elite runners?

    Science.gov (United States)

    Hottenrott, Kuno; Ludyga, Sebastian; Schulze, Stephan; Gronwald, Thomas; Jäger, Frank-Stephan

    2016-01-01

    Although alternating run/walk-periods are often recommended to novice runners, it is unclear, if this particular pacing strategy reduces the cardiovascular stress during prolonged exercise. Therefore, the aim of the study was to compare the effects of two different running strategies on selected cardiac biomarkers as well as marathon performance. Randomized experimental trial in a repeated measure design. Male (n=22) and female subjects (n=20) completed a marathon either with a run/walk strategy or running only. Immediately after crossing the finishing line cardiac biomarkers were assessed in blood taken from the cubital vein. Before (-7 days) and after the marathon (+4 days) subjects also completed an incremental treadmill test. Despite different pacing strategies, run/walk strategy and running only finished the marathon with similar times (04:14:25±00:19:51 vs 04:07:40±00:27:15 [hh:mm:ss]; p=0.377). In both groups, prolonged exercise led to increased B-type natriuretic peptide, creatine kinase MB isoenzyme and myoglobin levels (pmarathon. Elevated cTnI concentrations were observable in only two subjects. B-type natriuretic peptide (r=-0.363; p=0.041) and myoglobin levels (r=-0.456; p=0.009) were inversely correlated with the velocity at the individual anaerobic threshold. Run/walk strategy compared to running only reported less muscle pain and fatigue (p=0.006) after the running event. In conclusion, the increase in cardiac biomarkers is a reversible, physiological response to strenuous exercise, indicating temporary stress on the myocyte and skeletal muscle. Although a combined run/walk strategy does not reduce the load on the cardiovascular system, it allows non-elite runners to achieve similar finish times with less (muscle) discomfort. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  3. Noninvasive Measurement of EKG Properties of 3D Artificial Heart Muscle

    Directory of Open Access Journals (Sweden)

    Betsy H. Salazar

    2017-06-01

    Full Text Available Developing and testing a custom fabricated 16-electrode noninvasive direct contact system was necessary to assess the electrical properties of bioengineered heart muscle and to further evaluate the efficacy of cardiac constructs. By culturing neonatal rat primary cardiac cells on a fibrin gel, we constructed 3D artificial heart muscle (3D-AHM, as described in previous studies, which were used in validating this novel system. Electrical and mechanical functional assessment of the tissues was performed, which yielded contractile forces of the tissues, electrical field potential characteristics, and tissue conduction velocities (CV (20–170 cm/s. Immunohistological evaluation revealed the formation of cardiac tissue structures and cardiomyocyte proliferation. EKG data analysis also yielded time delays between signals in the range of 0–38 ms with electrical maps showing some evidence of synchronous contraction within the fabricated tissues. This study demonstrates the effectiveness and practicality of our novel EKG measuring system to acquire distinct electrical metrics of 3D-AHM, which will aid in increasing the viability and applicability of cardiac tissue constructs.

  4. Rhythm perturbations in acoustically paced treadmill walking after stroke.

    Science.gov (United States)

    Roerdink, Melvyn; Lamoth, Claudine J C; van Kordelaar, Joost; Elich, Peter; Konijnenbelt, Manin; Kwakkel, Gert; Beek, Peter J

    2009-09-01

    In rehabilitation, acoustic rhythms are often used to improve gait after stroke. Acoustic cueing may enhance gait coordination by creating a stable coupling between heel strikes and metronome beats and provide a means to train the adaptability of gait coordination to environmental changes, as required in everyday life ambulation. To examine the stability and adaptability of auditory-motor synchronization in acoustically paced treadmill walking in stroke patients. Eleven stroke patients and 10 healthy controls walked on a treadmill at preferred speed and cadence under no metronome, single-metronome (pacing only paretic or nonparetic steps), and double-metronome (pacing both footfalls) conditions. The stability of auditory-motor synchronization was quantified by the variability of the phase relation between footfalls and beats. In a separate session, the acoustic rhythms were perturbed and adaptations to restore auditory-motor synchronization were quantified. For both groups, auditory-motor synchronization was more stable for double-metronome than single-metronome conditions, with stroke patients exhibiting an overall weaker coupling of footfalls to metronome beats than controls. The recovery characteristics following rhythm perturbations corroborated the stability findings and further revealed that stroke patients had difficulty in accelerating their steps and instead preferred a slower-step response to restore synchronization. In gait rehabilitation practice, the use of acoustic rhythms may be more effective when both footfalls are paced. In addition, rhythm perturbations during acoustically paced treadmill walking may not only be employed to evaluate the stability of auditory-motor synchronization but also have promising implications for evaluation and training of gait adaptations in neurorehabilitation practice.

  5. Identification of cardiac rhythm features by mathematical analysis of vector fields.

    Science.gov (United States)

    Fitzgerald, Tamara N; Brooks, Dana H; Triedman, John K

    2005-01-01

    Automated techniques for locating cardiac arrhythmia features are limited, and cardiologists generally rely on isochronal maps to infer patterns in the cardiac activation sequence during an ablation procedure. Velocity vector mapping has been proposed as an alternative method to study cardiac activation in both clinical and research environments. In addition to the visual cues that vector maps can provide, vector fields can be analyzed using mathematical operators such as the divergence and curl. In the current study, conduction features were extracted from velocity vector fields computed from cardiac mapping data. The divergence was used to locate ectopic foci and wavefront collisions, and the curl to identify central obstacles in reentrant circuits. Both operators were applied to simulated rhythms created from a two-dimensional cellular automaton model, to measured data from an in situ experimental canine model, and to complex three-dimensional human cardiac mapping data sets. Analysis of simulated vector fields indicated that the divergence is useful in identifying ectopic foci, with a relatively small number of vectors and with errors of up to 30 degrees in the angle measurements. The curl was useful for identifying central obstacles in reentrant circuits, and the number of velocity vectors needed increased as the rhythm became more complex. The divergence was able to accurately identify canine in situ pacing sites, areas of breakthrough activation, and wavefront collisions. In data from human arrhythmias, the divergence reliably estimated origins of electrical activity and wavefront collisions, but the curl was less reliable at locating central obstacles in reentrant circuits, possibly due to the retrospective nature of data collection. The results indicate that the curl and divergence operators applied to velocity vector maps have the potential to add valuable information in cardiac mapping and can be used to supplement human pattern recognition.

  6. Factors affecting the regulation of pacing: current perspectives

    Directory of Open Access Journals (Sweden)

    Mauger AR

    2014-09-01

    Full Text Available Alexis R Mauger Endurance Research Group, School of Sport and Exercise Sciences, Faculty of Science, University of Kent, Chatham, UK Abstract: During prolonged dynamic and rhythmic exercise, muscular pain and discomfort arises as a result of an increased concentration of deleterious metabolites. Sensed by peripheral nociceptors and transmitted via afferent feedback to the brain, this provides important information regarding the physiological state of the muscle. These sensations ultimately contribute to what is termed "exercise-induced pain". Despite being well recognized by athletes and coaches, and suggested to be integral to exercise performance, this construct has largely escaped attention in experimental work. This perspective article highlights the current understanding of pacing in endurance performance, and the causes of exercise-induced pain. A new perspective is described, which proposes how exercise-induced pain may be a contributing factor in helping individuals to regulate their work rate during exercise and thus provides an important construct in pacing. Keywords: pain, exercise-induced pain, discomfort, exercise performance, self-paced

  7. Optimal pacing strategy: From theoretical modeling to reality in 1500m speed skating

    NARCIS (Netherlands)

    Hettinga, F.J.; de Koning, J.J.; Schmidt, L.J.I.; Wind, N.A.C.; McIntosh, B.; Foster, C.

    2011-01-01

    Purpose: Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  8. Optimal pacing strategy : from theoretical modelling to reality in 1500-m speed skating

    NARCIS (Netherlands)

    Hettinga, F. J.; De Koning, J. J.; Schmidt, L. J. I.; Wind, N. A. C.; MacIntosh, B. R.; Foster, C.

    Purpose Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing

  9. Pacemaker Dependency after Cardiac Surgery: A Systematic Review of Current Evidence.

    Science.gov (United States)

    Steyers, Curtis M; Khera, Rohan; Bhave, Prashant

    2015-01-01

    Severe postoperative conduction disturbances requiring permanent pacemaker implantation frequently occur following cardiac surgery. Little is known about the long-term pacing requirements and risk factors for pacemaker dependency in this population. We performed a systematic review of the literature addressing rates and predictors of pacemaker dependency in patients requiring permanent pacemaker implantation after cardiac surgery. Using a comprehensive search of the Medline, Web of Science and EMBASE databases, studies were selected for review based on predetermined inclusion and exclusion criteria. A total of 8 studies addressing the endpoint of pacemaker-dependency were identified, while 3 studies were found that addressed the recovery of atrioventricular (AV) conduction endpoint. There were 10 unique studies with a total of 780 patients. Mean follow-up ranged from 6-72 months. Pacemaker dependency rates ranged from 32%-91% and recovery of AV conduction ranged from 16%-42%. There was significant heterogeneity with respect to the definition of pacemaker dependency. Several patient and procedure-specific variables were found to be independently associated with pacemaker dependency, but these were not consistent between studies. Pacemaker dependency following cardiac surgery occurs with variable frequency. While individual studies have identified various perioperative risk factors for pacemaker dependency and non-resolution of AV conduction disease, results have been inconsistent. Well-conducted studies using a uniform definition of pacemaker dependency might identify patients who will benefit most from early permanent pacemaker implantation after cardiac surgery.

  10. Leadless Pacing: Current State and Future Direction.

    Science.gov (United States)

    Merkel, Matthias; Grotherr, Philipp; Radzewitz, Andrea; Schmitt, Claus

    2017-12-01

    Leadless pacing is now an established alternative to conventional pacing with subcutaneous pocket and transvenous lead for patients with class I or II single-chamber pacing indication. Available 12-month follow-up data shows a 48% fewer major complication rate in patients with Micra™ compared to a historical control group in a nonrandomized study [1]. There is one system with Food and Drug Administration (FDA) approval and two with the Communauté Européenne (CE) mark. The OPS code for the implantation is 8-83d.3 and the procedure has recently been rated as a "new Examination and Treatment Method (NUB)" in the German DRG system, meaning adequate reimbursement is negotiable with health insurance providers. The systems offer similar generator longevity and programming possibilities as conventional pacemaker systems, including rate response, remote monitoring, and MRI safety. The biggest downsides to date are limitations to single-chamber stimulation, lack of long-time data, and concerns of handling of the system at the end of its life span. However, implant procedure complication rates and procedure times do not exceed conventional pacemaker operations, and proper training and patient selection is provided.

  11. Análise dos fatores de risco para mortalidade na estimulação pediátrica endocárdica transfemoral: experiência em longo prazo Risk factors analysis in transvenous pediatric pacing through femoral access: long-term experience

    Directory of Open Access Journals (Sweden)

    Roberto Costa

    2005-06-01

    Full Text Available OBJETIVO: A estimulação cardíaca permanente melhora a sobrevida de crianças com bradicardia congênita ou adquirida, embora a mortalidade após o implante de marcapasso permaneça relativamente alta. O objetivo deste estudo foi avaliar os resultados em longo prazo de crianças submetidas a implante de marcapasso endocárdico pela veia femoral, incluindo a identificação de fatores de risco associados à mortalidade. MÉTODO: De 1981 a 2000, 99 pacientes variando em idade de um dia a 13 anos (4,1 ± 3,6 com mediana = 3 anos foram submetidos a implante de marcapasso permanente pela via femoral devido a bradicardia de origem congênita (39,4%, pós-cirúrgica (54,5% ou adquirida não cirurgicamente (6,1%. RESULTADOS: Ao final de 7,1 ± 5,3 anos (708,3 pacientes-anos de seguimento, 18 (18,2% pacientes haviam morrido. A sobrevida atuarial foi de 85%, 79,5%, e 74,2%, aos cinco, 10, e 15 anos, respectivamente. Os fatores independentes de mortalidade identificados pela análise proporcional de Cox foram: menor idade ao implante (p = 0,028, presença de anomalias cardíacas não corrigidas ou presença de próteses intracardíacas (p = 0,0001 e evidências radiográficas de cardiomegalia (p = 0,035. CONCLUSÕES: A estimulação cardíaca endocárdica permanente pela via femoral apresenta expectativa de sobrevida comparável a outras técnicas, com baixas taxas de complicações devidas ao implante de marcapasso. A sobrevida em longo prazo foi limitada pela menor idade e dilatação cardíaca no momento do implante, assim como pela presença de defeitos cardíacos sem correção ou de próteses valvares.OBJECTIVE: Permanent cardiac pacing improves survival of children with congenital or acquired bradycardia, although mortality after pacing remains relatively high. The aim of this study was to evaluate the long-term outcomes of children who undergo permanent endocardial cardiac pacing via the femoral vein, including the identification of associated

  12. Predicting Successful Completion Using Student Delay Indicators in Undergraduate Self-Paced Online Courses

    Science.gov (United States)

    Lim, Janine M.

    2016-01-01

    Self-paced online courses meet flexibility and learning needs of many students, but skepticism persists regarding the quality and the tendency for students to procrastinate in self-paced courses. Research is needed to understand procrastination and delay patterns of students in online self-paced courses to predict successful completion and…

  13. The Efficacy of Self-Paced Study in Multitrial Learning

    Science.gov (United States)

    de Jonge, Mario; Tabbers, Huib K.; Pecher, Diane; Jang, Yoonhee; Zeelenberg, René

    2015-01-01

    In 2 experiments we investigated the efficacy of self-paced study in multitrial learning. In Experiment 1, native speakers of English studied lists of Dutch-English word pairs under 1 of 4 imposed fixed presentation rate conditions (24 × 1 s, 12 × 2 s, 6 × 4 s, or 3 × 8 s) and a self-paced study condition. Total study time per list was equated for…

  14. PACE: A Browsable Graphical Interface.

    Science.gov (United States)

    Beheshti, Jamshid; And Others

    1996-01-01

    Describes PACE (Public Access Catalogue Extension), an alternative interface designed to enhance online catalogs by simulating images of books and library shelves to help users browse through the catalog. Results of a test in a college library against a text-based online public access catalog, including student attitudes, are described.…

  15. Pacing-induced Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Alex Koo

    2017-10-01

    Full Text Available We present a case of pacing-induced cardiomyopathy. The patient presented with clinical symptoms of dyspnea, leg swelling, and orthopnea several months after a dual-chambered pacemaker was placed for third-degree heart block. The echocardiogram demonstrated a depressed ejection fraction. Coronary angiography was performed, which showed widely patent vessels. Single- and dual-chambered pacemakers create ventricular dyssynchrony, which in turn can cause structural, molecular changes leading to cardiomyopathy. With early intervention of biventricular pacemaker replacement, these changes can be reversible; thus, a timely diagnosis and awareness is warranted.

  16. Sleep apnea detection by a cardiac resynchronization device integrated thoracic impedance sensor: A validation study against the gold standard polysomnography.

    Science.gov (United States)

    Barbieri, Fabian; Dichtl, Wolfgang; Heidbreder, Anna; Brandauer, Elisabeth; Stefani, Ambra; Adukauskaite, Agne; Senoner, Thomas; Schgör, Wilfried; Hintringer, Florian; Högl, Birgit

    2018-01-01

    Sleep disordered breathing is a common but often undiagnosed comorbidity in heart failure patients. Cardiac implantable electronic devices used for cardiac resynchronization therapy (CRT) may detect sleep apnea by use of a transthoracic impedance sensor. Validation of the AP scan® algorithm (Boston Scientific®) was performed by using the diagnostic gold standard polysomnography (PSG). Forty-one patients with impaired left ventricular ejection fraction, frequent right ventricular pacing due to atrioventricular block and heart failure symptoms despite optimal medical therapy underwent upgrading to biventricular pacing. Within one month after left ventricular lead implantation, sleep apnea was assessed by single-night PSG and AP scan® measurements. AP scan® measurements were valid in only 21 of 41 (51.2%) patients in the index night of the PSG. The PSG determined apnea-hypopnea index did not correlate statistically significant with the AP scan® measurements (r = 0.41, 95% confidence interval -0.05-0.72, p = 0.07). The degree of overestimation is displayed by using the Bland-Altman method: mean difference -12.4, standard deviation ± 15.8, 95% confidence interval -43.3-18.6. In heart failure patients receiving CRT upgrading, the AP scan® algorithm may need further improvement before it can be recommended for sleep apnea detection.

  17. Application of PACE Principles for Population Health Management of Frail Older Adults.

    Science.gov (United States)

    Stefanacci, Richard G; Reich, Shelley; Casiano, Alex

    2015-10-01

    To determine which practices would have the most impact on reducing hospital and emergency department admissions and nursing home placement among older adults with multiple comorbid conditions, a literature search and survey were conducted to identify and prioritize comprehensive care principles as practiced in the Program of All-inclusive Care for the Elderly (PACE). PACE medical directors and members of the PACE interdisciplinary team (IDT) were surveyed to gain their insights on the most impactful practices, which were identified as: End-of-Life Management, Caregiver Support, Management of Red Flags, Medication Management, Participant and Caregiver Health Care System Literacy, and Care Coordination. In addition, this research evaluated measures that could be used to assess an organization's level of success with regard to each of the 6 PACE practices identified. The results reported in this article, found through a survey with PACE medical directors and IDT members concerning effective interventions, can be viewed as strategies to improve care for older adults, enabling them to maintain their independence in the community, avoid the expense of facility-based care, and enhance their quality of life.

  18. Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs. Electrophysiological remodeling.

    Science.gov (United States)

    Elvan, A; Wylie, K; Zipes, D P

    1996-12-01

    We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.

  19. Artificial muscle: the human chimera is the future.

    Science.gov (United States)

    Tozzi, P

    2011-12-14

    Severe heart failure and cerebral stroke are broadly associated with the impairment of muscular function that conventional treatments struggle to restore. New technologies enable the construction of "smart" materials that could be of great help in treating diseases where the main problem is muscle weakness. These materials "behave" similarly to biological systems, because the material directly converts energy, for example electrical energy into movement. The extension and contraction occur silently like in natural muscles. The real challenge is to transfer this amazing technology into devices that restore or replace the mechanical function of failing muscle. Cardiac assist devices based on artificial muscle technology could envelope a weak heart and temporarily improve its systolic function, or, if placed on top of the atrium, restore the atrial kick in chronic atrial fibrillation. Artificial sphincters could be used to treat urinary incontinence after prostatectomy or faecal incontinence associated with stomas. Artificial muscles can restore the ability of patients with facial paralysis due to stroke or nerve injury to blink. Smart materials could be used to construct an artificial oesophagus including peristaltic movement and lower oesophageal sphincter function to replace the diseased oesophagus thereby avoiding the need for laparotomy to mobilise stomach or intestine. In conclusion, in the near future, smart devices will integrate with the human body to fill functional gaps due to organ failure, and so create a human chimera.

  20. Visual aided pacing in respiratory maneuvers

    Energy Technology Data Exchange (ETDEWEB)

    Rambaudi, L R [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Rossi, E [Catedra de Bioingenieria II (Argentina); Mantaras, M C [Catedra de Bioingenieria II (Argentina); Perrone, M S [Laboratorio de Biofisica y Fisiologia ' Antonio Sadi Frumento' (Argentina); Siri, L Nicola [Catedra de Bioingenieria II (Argentina)

    2007-11-15

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display.

  1. Visual aided pacing in respiratory maneuvers

    International Nuclear Information System (INIS)

    Rambaudi, L R; Rossi, E; Mantaras, M C; Perrone, M S; Siri, L Nicola

    2007-01-01

    A visual aid to pace self-controlled respiratory cycles in humans is presented. Respiratory manoeuvres need to be accomplished in several clinic and research procedures, among others, the studies on Heart Rate Variability. Free running respiration turns to be difficult to correlate with other physiologic variables. Because of this fact, voluntary self-control is asked from the individuals under study. Currently, an acoustic metronome is used to pace respiratory frequency, its main limitation being the impossibility to induce predetermined timing in the stages within the respiratory cycle. In the present work, visual driven self-control was provided, with separate timing for the four stages of a normal respiratory cycle. This visual metronome (ViMet) was based on a microcontroller which power-ON and -OFF an eight-LED bar, in a four-stage respiratory cycle time series handset by the operator. The precise timing is also exhibited on an alphanumeric display

  2. Atrial overexpression of angiotensin-converting enzyme 2 improves the canine rapid atrial pacing-induced structural and electrical remodeling. Fan, ACE2 improves atrial substrate remodeling.

    Science.gov (United States)

    Fan, Jinqi; Zou, Lili; Cui, Kun; Woo, Kamsang; Du, Huaan; Chen, Shaojie; Ling, Zhiyu; Zhang, Quanjun; Zhang, Bo; Lan, Xianbin; Su, Li; Zrenner, Bernhard; Yin, Yuehui

    2015-01-01

    The purpose of this study was to investigate whether atrial overexpression of angiotensin-converting enzyme 2 (ACE2) by homogeneous transmural atrial gene transfer can reverse atrial remodeling and its mechanisms in a canine atrial-pacing model. Twenty-eight mongrel dogs were randomly divided into four groups: Sham-operated, AF-control, gene therapy with adenovirus-enhanced green fluorescent protein (Ad-EGFP) and gene therapy with Ad-ACE2 (Ad-ACE2) (n = 7 per subgroup). AF was induced in all dogs except the Sham-operated group by rapid atrial pacing at 450 beats/min for 2 weeks. Ad-EGFP and Ad-ACE2 group then received epicardial gene painting. Three weeks after gene transfer, all animals except the Sham group underwent rapid atrial pacing for another 3 weeks and then invasive electrophysiological, histological and molecular studies. The Ad-ACE2 group showed an increased ACE2 and Angiotensin-(1-7) expression, and decreased Angiotensin II expression in comparison with Ad-EGFP and AF-control group. ACE2 overexpression attenuated rapid atrial pacing-induced increase in activated extracellular signal-regulated kinases and mitogen-activated protein kinases (MAPKs) levels, and decrease in MAPK phosphatase 1(MKP-1) level, resulting in attenuation of atrial fibrosis collagen protein markers and transforming growth factor-β1. Additionally, ACE2 overexpression also modulated the tachypacing-induced up-regulation of connexin 40, down-regulation of connexin 43 and Kv4.2, and significantly decreased the inducibility and duration of AF. ACE2 overexpression could shift the renin-angiotensin system balance towards the protective axis, attenuate cardiac fibrosis remodeling associated with up-regulation of MKP-1 and reduction of MAPKs activities, modulate tachypacing-induced ion channels and connexin remodeling, and subsequently reduce the inducibility and duration of AF.

  3. The Influence of a Pacesetter on Psychological Responses and Pacing Behavior during a 1600 m Run

    Directory of Open Access Journals (Sweden)

    Christopher L. Fullerton, Andrew M. Lane, Tracey J. Devonport

    2017-12-01

    Full Text Available This study compared the effects of following a pacer versus following a self-paced plan on psychological responses and pacing behavior in well-trained distance runners. Pacing in the present study was individually tailored where each participant developed a personal strategy to ensure their goal time was achieved. We expected that following a pacer would associate with goal achievement, higher pre-run confidence, positive emotions and lower perceived exertion during performance. In a mixed-design repeated-measures study, nineteen well-trained runners completed two 1600m running time trials. Ten runners had a pacer (paced group who supported their individual pacing strategy, and nine participants self-paced running alone (control group. Both groups could check pace using their wrist watch. In contrast to our expectation, results indicated that the paced group reported higher pre-run anxiety with no significant differences in finish time, goal confidence, goal difficulty, perceived exertion, and self-rated performance between groups. We suggest that following a pacer is a skill that requires learning. Following a personalised pacer might associate with higher anxiety due to uncertainty in being able to keep up with the pacer and public visibility of dropping behind, something that is not so observable in a self-paced run completed alone. Future research should investigate mechanisms associated with effective pacing.

  4. A Monetary Reward Alters Pacing but Not Performance in Competitive Cyclists.

    Science.gov (United States)

    Skorski, Sabrina; Thompson, Kevin G; Keegan, Richard J; Meyer, Tim; Abbiss, Chris R

    2017-01-01

    Money has frequently been used as an extrinsic motivator since it is assumed that humans are willing to invest more effort for financial reward. However, the influence of a monetary reward on pacing and performance in trained athletes is not well-understood. Therefore, the aim of this study was to analyse the influence of a monetary reward in well-trained cyclists on their pacing and performance during short and long cycling time trials (TT). Twentythree cyclists (6 ♀, 17 ♂) completed 4 self-paced time trials (TTs, 2 short: 4 km and 6 min; 2 long: 20 km and 30 min); in a randomized order. Participants were separated into parallel, non-randomized "rewarded" and "non-rewarded" groups. Cyclists in the rewarded group received a monetary reward based on highest mean power output across all TTs. Cyclists in the non-rewarded group did not receive a monetary reward. Overall performance was not significantly different between groups in short or long TTs ( p > 0.48). Power output showed moderatly lower effect sizes at comencement of the short TTs ( P meandiff = 36.6 W; d > 0.44) and the 20 km TT ( P meandiff = 22.6 W; d = 0.44) in the rewarded group. No difference was observed in pacing during the 30 min TT ( p = 0.95). An external reward seems to have influenced pacing at the commencement of time trials. Participants in the non-rewarded group adopted a typical parabolic shaped pattern, whereas participants in the rewarded group started trials more conservatively. Results raise the possibility that using money as an extrinsic reward may interfere with regulatory processes required for effective pacing.

  5. A Monetary Reward Alters Pacing but Not Performance in Competitive Cyclists

    Directory of Open Access Journals (Sweden)

    Sabrina Skorski

    2017-09-01

    Full Text Available Money has frequently been used as an extrinsic motivator since it is assumed that humans are willing to invest more effort for financial reward. However, the influence of a monetary reward on pacing and performance in trained athletes is not well-understood. Therefore, the aim of this study was to analyse the influence of a monetary reward in well-trained cyclists on their pacing and performance during short and long cycling time trials (TT. Twentythree cyclists (6 ♀, 17 ♂ completed 4 self-paced time trials (TTs, 2 short: 4 km and 6 min; 2 long: 20 km and 30 min; in a randomized order. Participants were separated into parallel, non-randomized “rewarded” and “non-rewarded” groups. Cyclists in the rewarded group received a monetary reward based on highest mean power output across all TTs. Cyclists in the non-rewarded group did not receive a monetary reward. Overall performance was not significantly different between groups in short or long TTs (p > 0.48. Power output showed moderatly lower effect sizes at comencement of the short TTs (Pmeandiff = 36.6 W; d > 0.44 and the 20 km TT (Pmeandiff = 22.6 W; d = 0.44 in the rewarded group. No difference was observed in pacing during the 30 min TT (p = 0.95. An external reward seems to have influenced pacing at the commencement of time trials. Participants in the non-rewarded group adopted a typical parabolic shaped pattern, whereas participants in the rewarded group started trials more conservatively. Results raise the possibility that using money as an extrinsic reward may interfere with regulatory processes required for effective pacing.

  6. Gated blood pool imaging in the diagnosis and management of arrhythmia

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Kawai, Naoki; Okada, Mitsuhiro; Matsushima, Hideo; Kato, Rinya; Sotobata, Iwao; Tanahashi, Yoshibumi.

    1985-01-01

    The usefulness of multigated cardiac blood pool imaging in evaluating left ventricular function and ventricular activation was studied in patients with cardiac arrhythmias. Subjects consisted of 12 patients with the Wolff-Parkinson-White (WPW) syndrome; 20 with ventricular premature contractions (VPC); 21 with various modes of artificial pacemakers; and two normal controls. 1. Phase analysis was useful in localizing the bypass tract in patients with the WPW syndrome. In four patients with the WPW syndrome and five with VVI pacing, the phase difference between the posterolateral wall of the left ventricle (LV) and the right ventricular apex correlated significantly with the activation time difference between these two regions as assessed by endocardial electrograms (r = 0.94, p < 0.001). 2. Images of VPC were obtained using the bad beat rejection program in an ADAC computer system. The origin of VPCs evaluated by phase image coincided with results of standard 12-lead electrograms. 3. The LV ejection fraction (LVEF) decreased significantly (p < 0.001) after the injection of lidocaine (-3.7 %) or disopyramide (-6.2 %). The percent reduction in LVEF was significantly greater with disopyramide than with lidocaine (-15.1 vs -11.2 %). There was a significant correlation between the percent reduction in LVEF and the disopyramide plasma concentrations (r = -0.62, p < 0.001). 4. The influence of the pacing mode and exercise on LV function was studied in 21 patients with artificial pacemakers. In the VDD and DDD modes, end-diastolic volume (EDV) and cardiac output (CO) decreased after converting to VVI mode. CO increased markedly to approximately 250 % of the control value in the VDD and DDD, and moderately in the VVI and AAI modes during ergometer exercise. (J.P.N.)

  7. The value of right lateral decubitus position to decrease artificial defect of cardiac anterior wall in 99Tcm-MIBI SPECT myocardial perfusion imaging for women

    International Nuclear Information System (INIS)

    Huang Kemin; Feng Yanlin; Wen Guanghua; Liang Weitang; Yu Fengwen; Liu Dejun

    2013-01-01

    Objective: To explore the value of right lateral decubitus position MPI for differentiating myocardial perfusion defect from cardiac anterior wall attenuation artificial defect, caused by breast of woman. Methods: Forty-nine patients(average age (61.5±8.4) years) who had low likelihood of coronary artery disease and had perfusion defect in the anterior wall after exercise stress 99 Tc m -MIBI MPI were included. All underwent supine and right lateral decubitus position during resting SPECT images. The myocardial perfusion SPECT images at left ventricle were reconstructed and were measured by Bull's-eye, based on the counts. Results from both supine position imaging and right lateral decubitus position imaging were compared. Paired t test was used to statistically analyse the data by SPSS 13.0. Results: Compared with supine position, the counts of the anterior, inferior, apex and lateral wall in right lateral decubitus position were significantly higher: (71.30±3.53)% vs (66.50±3.85)%, (70.06±4.45)% vs (65.44±4.16)%, (77.90±3.00)% vs (75.81±4.08)%,(79.30±2.26)% vs (72.60±3.87)% (t=6.731, 5.286, 3.555, 10.885, all P<0.01). The counts of septal wall were significantly lower ((66.60±3.98)% vs (70.06±4.51)%, t=-4.625, P<0.01) in right lateral decubitus position than that in supine position. Among the different regions of anterior wall, the counts of the anterior-middle ((76.40 ± 3.80)% vs (68.60 ± 4.76)%) and anterior-apex region ((77.10±3.24)% vs (69.00±3.54)%) were significantly higher (t=9.916, 8.870, both P<0.01) in right lateral decubitus position than those in supine position, but there was insignificance ((56.94±6.06)% vs (58.50±4.98)%, t=-1.493, P>0.05) at anterior-basal region. The artificial defect of different degrees in anterior wall was observed in all patients in supine position, 23 cases (46.9%, 23/49) showed artificial defect in the anterior-middle region and 16 cases (32.7%, 16/49) in the anterior-apex region. All artificial defect

  8. Effect of age and performance on pacing of marathon runners

    Directory of Open Access Journals (Sweden)

    Nikolaidis PT

    2017-08-01

    Full Text Available Pantelis Theodoros Nikolaidis,1 Beat Knechtle2,3 1Exercise Physiology Laboratory, Attiki, Greece; 2Gesundheitszentrum St. Gallen, St. Gallen, 3Institute of Primary Care, University of Zurich, Zurich, Switzerland Abstract: Pacing strategies in marathon runners have previously been examined, especially with regard to age and performance level separately. However, less information about the age × performance interaction on pacing in age-group runners exists. The aim of the present study was to examine whether runners with similar race time and at different age differ for pacing. Data (women, n=117,595; men, n=180,487 from the “New York City Marathon” between 2006 and 2016 were analyzed. A between–within subjects analysis of variance showed a large main effect of split on race speed (p<0.001, η2=0.538 with the fastest speed in the 5–10 km split and the slowest in the 35–40 km. A small sex × split interaction on race speed was found (p<0.001, η2=0.035 with men showing larger increase in speed at 5 km and women at 25 km and 40 km (end spurt. An age-group × performance group interaction on Δspeed was shown for both sexes at 5 km, 10 km, 15 km, 20 km, 25 km, 30 km, 35 km, and 40 km (p<0.001, 0.001≤η2≤0.004, where athletes in older age-groups presented a relatively more even pace compared with athletes in younger age-groups, a trend that was more remarkable in the relatively slow performance groups. So far, the present study is the first one to observe an age × performance interaction on pacing; ie, older runners pace differently (smaller changes than younger runners with similar race time. These findings are of great practical interest for coaches working with marathon runners of different age, but similar race time. Keywords: running, master athlete, endurance, aerobic capacity, fatigue, gender, race time

  9. The Platform-Aware Compilation Environment (PACE)

    Science.gov (United States)

    2012-09-01

    The PACE Project provided full or partial support for the following graduate students: 1. Raj Barik (Rice) 2. Thomas Barr (Rice) 3...University, Houston, TX, Technical Report CS TR11-03, October 20, 2011. [7] Rajkishore Barik , Jisheng Zhao, and Vivek Sarkar, "Efficient Selection

  10. Universal algorithm for diagnosis of biventricular capture in patients with cardiac resynchronization therapy.

    Science.gov (United States)

    Jastrzebski, Marek; Kukla, Piotr; Fijorek, Kamil; Czarnecka, Danuta

    2014-08-01

    An accurate and universal method for diagnosis of biventricular (BiV) capture using a standard 12-lead electrocardiogram (ECG) would be useful for assessment of cardiac resynchronization therapy (CRT) patients. Our objective was to develop and validate such an ECG method for BiV capture diagnosis that would be independent of pacing lead positions-a major confounder that significantly influences the morphologies of paced QRS complexes. On the basis of an evaluation of 789 ECGs of 443 patients with heart failure and various right ventricular (RV) and left ventricular (LV) lead positions, the following algorithm was constructed and validated. BiV capture was diagnosed if the QRS in lead I was predominantly negative and either V1 QRS was predominantly positive or V6 QRS was of negative onset and predominantly negative (step 1), or if QRS complex duration was capture. The algorithm showed good accuracy (93%), sensitivity (97%), and specificity (90%) for detection of loss of LV capture. The performance of the algorithm did not differ among apical, midseptal, and outflow tract RV lead positions and various LV lead positions. LV capture leaves diagnostic hallmarks in the fused BiV QRS related to different vectors of depolarization and more rapid depolarization of the ventricles. An accurate two-step ECG algorithm for BiV capture diagnosis was developed and validated. This algorithm is universally applicable to all CRT patients, regardless of the positions of the pacing leads. ©2014 Wiley Periodicals, Inc.

  11. Artificial Neural Network for Total Laboratory Automation to Improve the Management of Sample Dilution.

    Science.gov (United States)

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.

  12. Establishing the framework to support bioartificial heart fabrication using fibrin-based three-dimensional artificial heart muscle.

    Science.gov (United States)

    Hogan, Matthew; Mohamed, Mohamed; Tao, Ze-Wei; Gutierrez, Laura; Birla, Ravi

    2015-02-01

    Only 3000 heart transplants are performed in the USA every year, leaving some 30 000-70 000 Americans without proper care. Current treatment modalities for heart failure have saved many lives yet still do not correct the underlying problems of congestive heart failure. Tissue engineering represents a potential field of study wherein a combination of cells, scaffolds, and/or bioreactors can be utilized to create constructs to mimic, replace, and/or repair defective tissue. The focus of this study was to generate a bioartificial heart (BAH) model using artificial heart muscle (AHM), composed of fibrin gel and neonatal rat cardiac myocytes, and a decellularized scaffold, formed by subjecting an adult rat heart to a series of decellularization solutions. By suturing the AHM around the outside of the decellularized heart and culturing while suspended in media, we were able to retain functional cardiac cells on the scaffold as evinced by visible contractility. Observed contractility rate was correlated with biopotential measurements to confirm essential functionality of cardiac constructs. Cross-sections of the BAH show successful decellularization of the scaffold and contiguous cell-rich AHM around the perimeter of the heart. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  13. Unilateral Laryngeal Pacing System and Its Functional Evaluation

    Directory of Open Access Journals (Sweden)

    Taiping Zeng

    2017-01-01

    Full Text Available Goal. To establish a reliable instrumental system for synchronized reactivation of a unilaterally paralyzed vocal fold and evaluate its functional feasibility. Methods. Unilateral vocal fold paralysis model was induced by destruction of the left recurrent laryngeal nerve (RLN in anesthetized dogs. With a micro controller-based electronic system, electromyography (EMG signals from cricothyroid (CT muscle on the ipsilateral side were recorded and used to trigger pacing of paralyzed vocalis muscles. The dynamic movement of vocal folds was continuously monitored using an endoscope, and the opening and closing of the glottis were quantified with customized imaging processing software. Results. The recorded video images showed that left side vocal fold was obviously paralyzed after destructing the RLN. Using the pacing system with feedback triggering EMG signals from the ipsilateral CT muscle, the paralyzed vocal fold was successfully reactivated, and its movement was shown to be synchronized with the healthy side. Significance. The developed unilateral laryngeal pacing system triggered by EMG from the ipsilateral side CT muscle could be successfully used in unilateral vocal fold paralysis with the advantage of avoiding disturbance to the healthy side muscles.

  14. The pace and shape of ageing

    DEFF Research Database (Denmark)

    Baudisch, Annette

    2011-01-01

    exhibits negligible ageing - contrary to the commonly held view that long-lived species are good candidates for negligible ageing. 5.Analysis of species in pace-shape space provides a tool to identify key determinants of the evolution of ageing for species across the tree of life....

  15. Long-term prognostic value of transesophageal atrial pacing stress echocardiography.

    Science.gov (United States)

    Płońska, Edyta; Kasprzak, Jarosław D; Kornacewicz-Jach, Zdzisława

    2005-07-01

    The aim of our study was to evaluate the long-term prognostic value of transesophageal atrial pacing stress echocardiography (TAPSE) for the prediction of cardiovascular events (myocardial infarction) and mortality at 10-year follow-up. TAPSE was applied as a diagnostic modality in 93 consecutive patients (mean age 45 +/- 8 years) who were diagnosed for the cause of chest pain. Long-term follow-up data were obtained from 87 (94%) patients with a mean duration of follow-up of 92 +/- 4 months. Stress echocardiography was performed using TAPSE with a mean pacing rate of 142 +/- 18/min. Predefined cardiac events occurred during the follow-up period in 45 (52%) patients, including 24 (28%) with hard end points: 10 (12%) with nonfatal myocardial infarction and 17 who died (events overlap). Positive result of TAPSE was found in 47 (54%) patients and among those with positive TAPSE result, 16 died (94% of total mortality) and 21 had a hard event (death or infarction-88% of total prevalence). Survival free from hard events was noted in 37 (92%) patients with negative TAPSE and only in 26 (55%) of those with positive TAPSE ( P = .001). Independent predictive factors for mortality were TAPSE positivity (relative risk with 95% confidence interval [RR/CI] = 39.6 [36.3-42.9], P = .0006) and diabetes (RR/CI = 10.2 [8.6-11.8], P = .0026). Independent predictive factors for myocardial infarction were diabetes (RR/CI = 8.1 [6.3-9.9], P = .0186) and significant coronary stenosis in angiography (RR/CI = 9.0 [6.8-11.2], P = .0479). Independent predictive factors for death or nonfatal myocardial infarction were TAPSE positivity (RR/CI = 12.3 [11.1-13.3], P = .0001) and diabetes (RR/CI = 7.0 [5.8-8.2], P = .0018). Positive TAPSE result carries long-term prognostic information regarding mortality and risk of myocardial infarction that can be used to identify patients requiring more aggressive treatment. Negative TAPSE allows highly accurate definition of low-risk population with

  16. Permanent pacing in infants and children: A single center experience in implantation and follow up

    Directory of Open Access Journals (Sweden)

    Rania Samir

    2011-09-01

    Conclusion: Permanent pacing in pediatric age group is relatively safe. However, there is substantial higher incidence of suboptimal pacing parameters and pacing system failures especially in younger and smaller children. Epicardial steroid eluting leads are comparable to endocardial steroid eluting leads in performance.

  17. Development of a force-reflecting robotic platform for cardiac catheter navigation.

    Science.gov (United States)

    Park, Jun Woo; Choi, Jaesoon; Pak, Hui-Nam; Song, Seung Joon; Lee, Jung Chan; Park, Yongdoo; Shin, Seung Min; Sun, Kyung

    2010-11-01

    Electrophysiological catheters are used for both diagnostics and clinical intervention. To facilitate more accurate and precise catheter navigation, robotic cardiac catheter navigation systems have been developed and commercialized. The authors have developed a novel force-reflecting robotic catheter navigation system. The system is a network-based master-slave configuration having a 3-degree of freedom robotic manipulator for operation with a conventional cardiac ablation catheter. The master manipulator implements a haptic user interface device with force feedback using a force or torque signal either measured with a sensor or estimated from the motor current signal in the slave manipulator. The slave manipulator is a robotic motion control platform on which the cardiac ablation catheter is mounted. The catheter motions-forward and backward movements, rolling, and catheter tip bending-are controlled by electromechanical actuators located in the slave manipulator. The control software runs on a real-time operating system-based workstation and implements the master/slave motion synchronization control of the robot system. The master/slave motion synchronization response was assessed with step, sinusoidal, and arbitrarily varying motion commands, and showed satisfactory performance with insignificant steady-state motion error. The current system successfully implemented the motion control function and will undergo safety and performance evaluation by means of animal experiments. Further studies on the force feedback control algorithm and on an active motion catheter with an embedded actuation mechanism are underway. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  18. Bloqueio atrioventricular no pós-operatório de cirurgia cardíaca valvar: incidência, fatores de risco e evolução hospitalar Atrioventricular block in the postoperative period of heart valve surgery: incidence, risk factors and hospital evolution

    Directory of Open Access Journals (Sweden)

    Andres Di Leoni Ferrari

    2011-09-01

    Full Text Available INTRODUÇÃO: Distúrbios do sistema de condução cardíaco são complicações potenciais e conhecidas dos procedimentos de cirurgia cardíaca valvar. OBJETIVOS: Investigar a associação entre fatores peri-operatórios com bloqueio atrioventricular (BAV e a necessidade de estimulação cardíaca artificial temporária (ECAT e, se necessário, implante de marcapasso definitivo no pós-operatório de cirurgia cardíaca (POCC valvar. MÉTODOS: Coorte histórica de pacientes submetidos a cirurgia cardíaca valvar, sendo realizada análise de banco de dados por regressão logística. RESULTADOS: No período de janeiro de 1996 a dezembro de 2008, foram realizadas 1102 cirurgias cardíacas valvares: 718 (65,2% na valva aórtica e 407 (36,9% na valva mitral; destas, 190 (17,2% cirurgias de revascularização miocárdica associadas à cirurgia valvar e 23 (2,1% cirurgias valvares combinadas (aórtica+mitral. Cento e oitenta e sete (17% pacientes apresentaram quadro clínico e eletrocardiográfico de BAV durante o POCC valvar, necessitando de ECAT. Quatorze (7,5% pacientes evoluíram para implante de marcapasso definitivo (1,27% do total da amostra. A análise multivariada evidenciou associação significativa de BAV com cirurgia de valva mitral (OR=1,76; IC 95% 1,08-2,37; P=0,002, implante de prótese biológica (OR=1,59; IC 95% 1,02-3,91; P= 0,039, idade maior que 60 anos (OR = 1,99; IC 95% 1,35-2,85; PINTRODUCTION: Disturbances of the cardiac conduction system are potential complications after cardiac valve surgery. OBJECTIVES: This study was designed to investigate the association between perioperative factors and atrio-ventricular block, the need for temporary cardiac artificial pacing and, if necessary, permanent pacemaker implantation after cardiac valve surgery. METHODS: Retrospective analysis of the Cardiac Surgery Database - Hospital São Lucas/PUCRS. The data are collected prospectively and analyzed retrospectively. RESULTS: Between January

  19. Modeling parameters that characterize pacing of elite female 800-m freestyle swimmers.

    Science.gov (United States)

    Lipińska, Patrycja; Allen, Sian V; Hopkins, Will G

    2016-01-01

    Pacing offers a potential avenue for enhancement of endurance performance. We report here a novel method for characterizing pacing in 800-m freestyle swimming. Websites provided 50-m lap and race times for 192 swims of 20 elite female swimmers between 2000 and 2013. Pacing for each swim was characterized with five parameters derived from a linear model: linear and quadratic coefficients for effect of lap number, reductions from predicted time for first and last laps, and lap-time variability (standard error of the estimate). Race-to-race consistency of the parameters was expressed as intraclass correlation coefficients (ICCs). The average swim was a shallow negative quadratic with slowest time in the eleventh lap. First and last laps were faster by 6.4% and 3.6%, and lap-time variability was ±0.64%. Consistency between swimmers ranged from low-moderate for the linear and quadratic parameters (ICC = 0.29 and 0.36) to high for the last-lap parameter (ICC = 0.62), while consistency for race time was very high (ICC = 0.80). Only ~15% of swimmers had enough swims (~15 or more) to provide reasonable evidence of optimum parameter values in plots of race time vs. each parameter. The modest consistency of most of the pacing parameters and lack of relationships between parameters and performance suggest that swimmers usually compensated for changes in one parameter with changes in another. In conclusion, pacing in 800-m elite female swimmers can be characterized with five parameters, but identifying an optimal pacing profile is generally impractical.

  20. Atrial SERCA2a Overexpression Has No Affect on Cardiac Alternans but Promotes Arrhythmogenic SR Ca2+ Triggers.

    Science.gov (United States)

    Nassal, Michelle M J; Wan, Xiaoping; Laurita, Kenneth R; Cutler, Michael J

    2015-01-01

    Atrial fibrillation (AF) is the most common arrhythmia in humans, yet; treatment has remained sub-optimal due to poor understanding of the underlying mechanisms. Cardiac alternans precede AF episodes, suggesting an important arrhythmia substrate. Recently, we demonstrated ventricular SERCA2a overexpression suppresses cardiac alternans and arrhythmias. Therefore, we hypothesized that atrial SERCA2a overexpression will decrease cardiac alternans and arrhythmias. Adult rat isolated atrial myocytes where divided into three treatment groups 1) Control, 2) SERCA2a overexpression (Ad.SERCA2a) and 3) SERCA2a inhibition (Thapsigargin, 1μm). Intracellular Ca2+ was measured using Indo-1AM and Ca2+ alternans (Ca-ALT) was induced with a standard ramp pacing protocol. As predicted, SR Ca2+ reuptake was enhanced with SERCA2a overexpression (poverexpression or inhibition when compared to controls (p = 0.73). In contrast, SERCA2a overexpression resulted in increased premature SR Ca2+ (SCR) release compared to control myocytes (28% and 0%, p overexpression in atrial myocytes can increase SCR, which may be arrhythmogenic.

  1. Sawtooth Pacing by Real-Time Auxiliary Power Control in a Tokamak Plasma

    International Nuclear Information System (INIS)

    Goodman, T. P.; Felici, F.; Sauter, O.; Graves, J. P.

    2011-01-01

    In the standard scenario of tokamak plasma operation, sawtooth crashes are the main perturbations that can trigger performance-degrading, and potentially disruption-generating, neoclassical tearing modes. This Letter demonstrates sawtooth pacing by real-time control of the auxiliary power. It is shown that the sawtooth crash takes place in a reproducible manner shortly after the removal of that power, and this can be used to precisely prescribe, i.e., pace, the individual sawteeth. In combination with preemptive stabilization of the neoclassical tearing modes, sawtooth pacing provides a new sawtooth control paradigm for improved performance in burning plasmas.

  2. Optimal pacing strategy: from theoretical modelling to reality in 1500-m speed skating.

    Science.gov (United States)

    Hettinga, F J; De Koning, J J; Schmidt, L J I; Wind, N A C; Macintosh, B R; Foster, C

    2011-01-01

    Athletes are trained to choose the pace which is perceived to be correct during a specific effort, such as the 1500-m speed skating competition. The purpose of the present study was to "override" self-paced (SP) performance by instructing athletes to execute a theoretically optimal pacing profile. Seven national-level speed-skaters performed a SP 1500-m which was analysed by obtaining velocity (every 100 m) and body position (every 200 m) with video to calculate total mechanical power output. Together with gross efficiency and aerobic kinetics, obtained in separate trials, data were used to calculate aerobic and anaerobic power output profiles. An energy flow model was applied to SP, simulating a range of pacing strategies, and a theoretically optimal pacing profile was imposed in a second race (IM). Final time for IM was ∼2 s slower than SP. Total power distribution per lap differed, with a higher power over the first 300 m for IM (637.0 (49.4) vs 612.5 (50.0) W). Anaerobic parameters did not differ. The faster first lap resulted in a higher aerodynamic drag coefficient and perhaps a less effective push-off. Experienced athletes have a well-developed performance template, and changing pacing strategy towards a theoretically optimal fast start protocol had negative consequences on speed-skating technique and did not result in better performance.

  3. A Pilot Study on the Effects of Slow Paced Breathing on Current Food Craving.

    Science.gov (United States)

    Meule, Adrian; Kübler, Andrea

    2017-03-01

    Heart rate variability biofeedback (HRV-BF) involves slow paced breathing (approximately six breaths per minute), thereby maximizing low-frequent heart rate oscillations and baroreflex gain. Mounting evidence suggests that HRV-BF promotes symptom reductions in a variety of physical and mental disorders. It may also positively affect eating behavior by reducing food cravings. The aim of the current study was to investigate if slow paced breathing can be useful for attenuating momentary food craving. Female students performed paced breathing either at six breaths per minute (n = 32) or at nine breaths per minute (n = 33) while watching their favorite food on the computer screen. Current food craving decreased during a first resting period, increased during paced breathing, and decreased during a second resting period in both conditions. Although current hunger increased in both conditions during paced breathing as well, it remained elevated after the second resting period in the nine breaths condition only. Thus, breathing rate did not influence specific food craving, but slow paced breathing appeared to have a delayed influence on state hunger. Future avenues are suggested for the study of HRV-BF in the context of eating behavior.

  4. Self-Paced Physics, Segments 24-27.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this fifth problems and solutions book used as a part of student course work. The subject matter is related to work in electric fields, potential differences, parallel plates, electric potential energies, potential gradients, capacitances, and capacitor circuits.…

  5. Self-Paced Physics, Segments 28-31.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this sixth problems and solutions book used as a part of student course work. The subject matter is related to electric currents, current densities, resistances, Ohm's law, voltages, Joule heating, electromotive forces, single loop circuits, series and parallel…

  6. Self-Paced Physics, Segments 37-40.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Four study segments of the Self-Paced Physics Course materials are presented in this eighth problems and solutions book used as a part of course assignments. The content is related to magnetic induction, Faraday's law, induced currents, Lenz's law, induced electromotive forces, time-varying magnetic fields, self-inductance, inductors,…

  7. Lessons in Commercial PACE Leadership: The Path from Legislation to Launch

    Energy Technology Data Exchange (ETDEWEB)

    Leventis, G; Schwartz, LC; Kramer, C; Deason, J

    2018-02-27

    Nonresidential buildings are responsible for over a quarter of primary energy consumption in the United States. Efficiency improvements in these buildings could result in significant energy and utility bill savings. To unlock those potential savings, a number of market barriers to energy efficiency must be addressed. Commercial Property Assessed Clean Energy (C-PACE) financing programs can help overcome several of these barriers with minimal investment from state and local governments. With programs established or under development in 22 states, and at least $521 million in investments so far, other state and local governments are interested in bringing the benefits of C-PACE to their jurisdictions. Lessons in Commercial PACE Leadership: The Path from Legislation to Launch, aims to fast track the set-up of C-PACE programs for state and local governments by capturing the lessons learned from leaders. The report examines the list of potential program design options and important decision points in setting up a C-PACE program, tradeoffs for available options, and experiences of stakeholders that have gone through (or are going through) the process. C-PACE uses a voluntary special property assessment to facilitate energy and other improvements in commercial buildings. For example: - Long financing terms under C-PACE can produce cash flow-positive -- projects to help overcome a focus on short paybacks. - Payment obligations can transfer to subsequent owners, mitigating concern about investing in improvements for a building that may be sold before the return on the investment is fully realized. - 100% of both hard and soft costs can be financed. To capture the benefits of C-PACE financing, state and local governments must navigate numerous decision points and engage with stakeholders to set-up or join a program. Researchers interviewed experts (including state and local sponsors, program administrators, capital providers and industry experts) on their lessons learned and

  8. Accuracy of computer-calculated and manual QRS duration assessments: Clinical implications to select candidates for cardiac resynchronization therapy.

    Science.gov (United States)

    De Pooter, Jan; El Haddad, Milad; Stroobandt, Roland; De Buyzere, Marc; Timmermans, Frank

    2017-06-01

    QRS duration (QRSD) plays a key role in the field of cardiac resynchronization therapy (CRT). Computer-calculated QRSD assessments are widely used, however inter-manufacturer differences have not been investigated in CRT candidates. QRSD was assessed in 377 digitally stored ECGs: 139 narrow QRS, 140 LBBB and 98 ventricular paced ECGs. Manual QRSD was measured as global QRSD, using digital calipers, by two independent observers. Computer-calculated QRSD was assessed by Marquette 12SL (GE Healthcare, Waukesha, WI, USA) and SEMA3 (Schiller, Baar, Switzerland). Inter-manufacturer differences of computer-calculated QRSD assessments vary among different QRS morphologies: narrow QRSD: 4 [2-9] ms (median [IQR]), p=0.010; LBBB QRSD: 7 [2-10] ms, p=0.003 and paced QRSD: 13 [6-18] ms, p=0.007. Interobserver differences of manual QRSD assessments measured: narrow QRSD: 4 [2-6] ms, p=non-significant; LBBB QRSD: 6 [3-12] ms, p=0.006; paced QRSD: 8 [4-18] ms, p=0.001. In LBBB ECGs, intraclass correlation coefficients (ICCs) were comparable for inter-manufacturer and interobserver agreement (ICC 0.830 versus 0.837). When assessing paced QRSD, manual measurements showed higher ICC compared to inter-manufacturer agreement (ICC 0.902 versus 0.776). Using guideline cutoffs of 130ms, up to 15% of the LBBB ECGs would be misclassified as <130ms or ≥130ms by at least one method. Using a cutoff of 150ms, this number increases to 33% of ECGs being misclassified. However, by combining LBBB-morphology and QRSD, the number of misclassified ECGs can be decreased by half. Inter-manufacturer differences in computer-calculated QRSD assessments are significant and may compromise adequate selection of individual CRT candidates when using QRSD as sole parameter. Paced QRSD should preferentially be assessed by manual QRSD measurements. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Ventricular Pacing via the Coronary Sinus in a Patient with a Mechanical Tricuspid Valve Prosthesis

    Directory of Open Access Journals (Sweden)

    Janice Swampillai, MD

    2011-01-01

    Full Text Available Implantation of a transvenous endocardial pacing lead in the right ventricle is contra-indicated after mechanical tricuspid valve replacement; therefore a surgical approach to the epicardium is usually required. This case report describes ventricular pacing via a branch of the coronary sinus in a patient with mechanical mitral, aortic and tricuspid valve replacements. In conclusion, this approach is minimally invasive, provides effective ventricular stimulation with low pacing threshold and stable lead position, and is a feasible option when transvenous right ventricular pacing is not possible.

  10. Neurogenesis in the olfactory bulb induced by paced mating in the female rat is opioid dependent.

    Directory of Open Access Journals (Sweden)

    Marianela Santoyo-Zedillo

    Full Text Available The possibility to control the rate of sexual stimulation that the female rat receives during a mating encounter (pacing increases the number of newborn neurons that reach the granular layer of the accessory olfactory bulb (AOB. If females mate repeatedly, the increase in the number of neurons is observed in other regions of the AOB and in the main olfactory bulb (MOB. It has also been shown that paced mating induces a reward state mediated by opioids. There is also evidence that opioids modulate neurogenesis. In the present study, we evaluated whether the opioid receptor antagonist naloxone (NX could reduce the increase in neurogenesis in the AOB induced by paced mating. Ovariectomized female rats were randomly divided in 5 different groups: 1 Control (not mated treated with saline, 2 control (not mated treated with naloxone, 3 females that mated without controlling the sexual interaction (no-pacing, 4 females injected with saline before pacing the sexual interaction and 5 females injected with NX before a paced mating session. We found, as previously described, that paced mating induced a higher number of new cells in the granular layer of the AOB. The administration of NX before paced mating, blocked the increase in the number of newborn cells and prevented these cells from differentiating into neurons. These data suggest that opioid peptides play a fundamental role in the neurogenesis induced by paced mating in female rats.

  11. Permanent and temporary pacemaker implantation after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Bacal Fernando

    2000-01-01

    Full Text Available PURPOSE:To determine the indication for and incidence and evolution of temporary and permanent pacemaker implantation in cardiac transplant recipients. METHODS: A retrospective review of 114 patients who underwent orthotopic heart transplantation InCor (Heart Institute USP BR between March 1985 and May 1993. We studied the incidence of and indication for temporary pacing, the relationship between pacing and rejection, the need for pemanent pacing and the clinical follow-up. RESULTS: Fourteen of 114 (12%heart transplant recipients required temporary pacing and 4 of 114 (3.5% patients required permanent pacing. The indication for temporary pacing was sinus node dysfunction in 11 patients (78.5% and atrioventricular (AV block in 3 patients (21.4%. The indication for permanent pacemaker implantation was sinus node dysfunction in 3 patients (75% and atrioventricular (AV block in 1 patient (25%. We observed rejection in 3 patients (21.4% who required temporary pacing and in 2 patients (50% who required permanent pacing. The previous use of amiodarone was observed in 10 patients (71.4% with temporary pacing. Seven of the 14 patients (50% died during follow-up. CONCLUSION: Sinus node dysfunction was the principal indication for temporary and permanent pacemaker implantation in cardiac transplant recipients. The need for pacing was related to worse prognosis after cardiac transplantation.

  12. On the pace of fertility decline in sub-Saharan Africa

    OpenAIRE

    David Shapiro; Andrew Hinde

    2017-01-01

    Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa.Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world.Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they ...

  13. A Report of Brugada Syndrome Presenting with Cardiac Arrest Triggered by Verapamil Intoxication.

    Science.gov (United States)

    Yakut, Kahraman; Erdoğan, İlkay; Varan, Birgül; Atar, İlyas

    2017-12-01

    Brugada syndrome is a disease characterized by a specific electrocardiographic pattern and an increased risk of sudden cardiac death. We present this case with the updated literature to emphasise the need to consider the diagnosis of Brugada syndrome in patients admitted to the emergency ward with sudden cardiac arrest. A 16-year-old female patient was admitted to the emergency ward with complaints of weakness and abdominal pain, and she had four cardiac arrests during her evaluation period. She was referred to our clinic for permanent pacemaker implantation. She was on a temporary pace maker after having had C-reactive protein. Her physical exam was normal except for bilaterally decreased lung sounds. Lung x-ray and computed tomography, which were performed by another institution, revealed minimal pleural effusion and nothing else of significance. Blood and peritoneal fluid samples were sterile. Echocardiographic exam and cardiac enzymes were also in the normal ranges. Electrocardiographic showed incomplete right branch block in leads V1 and V2. An ajmaline test revealed specific electrocardiographic findings of the type I Brugada pattern. We proposed implanting an implantable cardioverter defibrillator to the patient as there were positive findings on the ajmaline test as well as a history of sudden cardiac arrest. After this treatment proposal, the patient's family admitted that she had taken a high dose of verapamil and thus, the encountered bradycardia was associated with verapamil overuse. The ajmaline test was repeated as it was contemplated that the previous positive ajmaline test had been associated with verapamil overuse. Implantable cardioverter defibrillator implantation was proposed again as there was a history of sudden cardiac arrest; however, the family did not consent to implantable cardioverter defibrillator, and the patient was discharged and followed up. Brugada syndrome should be considered for patients who are admitted to the emergency ward

  14. Pacing, Pixels, and Paper: Flexibility in Learning Words from Flashcards

    Directory of Open Access Journals (Sweden)

    Kara Sage

    2016-08-01

    Full Text Available The present study focused on how self-control over pace might help learners successfully extract information from digital learning aids. Past research has indicated that too much control over pace can be overwhelming, but too little control over pace can be ineffective. Within the popular self-testing domain of flashcards, we sought to elucidate the optimal level of user control for digital learning and compare learning outcomes between paper and digital flashcards. College students learned vocabulary from paper flashcards or one of several digital flashcard versions and were scored on their memory recall and asked about their perceptions of the learning process. With digital flashcards, students were randomly assigned to an automatic slideshow of cards with no user control, automatic slideshow with pre-set pauses, automatic slideshow where users could press the spacebar to pause at any time, or a self-paced slideshow with complete user control. Users reported feeling more in control when indeed having some control, but ultimately memory recall, cognitive load, and satisfaction were similar across the five versions. However, memory recall was positively related to user satisfaction with their specific flashcard set, and negatively related to users’ perceived mental effort and difficulty. Notably, whether paper or digital, students showed individual variability in how they advanced through the words. This research adds to the educational literature by suggesting that paper and digital flashcards are equally viable options for students. Given differences between individual users and the connection between satisfaction and recall, individualistic options that offer, but do not force, some control over pace seem ideal. Paper flashcards may already include such options, and e-flashcards should offer similar adaptive features to appeal to a wide variety of users.

  15. Pacing and awareness: brain regulation of physical activity.

    Science.gov (United States)

    Edwards, A M; Polman, R C J

    2013-11-01

    The aim of this current opinion article is to provide a contemporary perspective on the role of brain regulatory control of paced performances in response to exercise challenges. There has been considerable recent conjecture as to the role of the brain during exercise, and it is now broadly accepted that fatigue does not occur without brain involvement and that all voluntary activity is likely to be paced at some level by the brain according to individualised priorities and knowledge of personal capabilities. This article examines the role of pacing in managing and distributing effort to successfully accomplish physical tasks, while extending existing theories on the role of the brain as a central controller of performance. The opinion proposed in this article is that a central regulator operates to control exercise performance but achieves this without the requirement of an intelligent central governor located in the subconscious brain. It seems likely that brain regulation operates at different levels of awareness, such that minor homeostatic challenges are addressed automatically without conscious awareness, while larger metabolic disturbances attract conscious awareness and evoke a behavioural response. This supports the view that the brain regulates exercise performance but that the interpretation of the mechanisms underlying this effect have not yet been fully elucidated.

  16. Initial Experience with IV Ketamine Infusion for Treatment of Post Sternotomy Pain in a Patient with a Total Artificial Heart.

    Science.gov (United States)

    Maher, Dermot P; Loyferman, Rusty; Yumul, Roya; Louy, Charles

    2015-01-01

    The implantation of total artificial hearts (TAH) via midline sternotomy for the treatment of severe biventricular cardiac dysfunction is associated with complex postoperative pain management. Ketamaine increases blood pressure by raising sympathetic outflow and cardiac output; however, ketamine is a direct vasodilator on isolated arterial tissues. In the setting of a TAH with a mechanically fixed cardiac output, a ketamine infusion for postoperative pain control has the potential to decrease blood pressure due to direct arterial vasodilation. We present the initial experience with a ketamine infusion in a patient with a TAH with minimal observed decreases in blood pressure and significantly improved postoperative pain.

  17. Oxidized CaMKII causes cardiac sinus node dysfunction in mice

    OpenAIRE

    Swaminathan, Paari Dominic; Purohit, Anil; Soni, Siddarth; Voigt, Niels; Singh, Madhu V.; Glukhov, Alexey V.; Gao, Zhan; He, B. Julie; Luczak, Elizabeth D.; Joiner, Mei-ling A.; Kutschke, William; Yang, Jinying; Donahue, J. Kevin; Weiss, Robert M.; Grumbach, Isabella M.

    2011-01-01

    Sinus node dysfunction (SND) is a major public health problem that is associated with sudden cardiac death and requires surgical implantation of artificial pacemakers. However, little is known about the molecular and cellular mechanisms that cause SND. Most SND occurs in the setting of heart failure and hypertension, conditions that are marked by elevated circulating angiotensin II (Ang II) and increased oxidant stress. Here, we show that oxidized calmodulin kinase II (ox-CaMKII) is a biomark...

  18. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    International Nuclear Information System (INIS)

    Kirova, Youlia M.; Menard, Jean; Chargari, Cyrus; Mazal, Alejandro; Kirov, Krassen

    2012-01-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  19. Case study thoracic radiotherapy in an elderly patient with pacemaker: The issue of pacing leads

    Energy Technology Data Exchange (ETDEWEB)

    Kirova, Youlia M., E-mail: youlia.kirova@curie.net [Department of Radiation Oncology, Institut Curie, Paris (France); Menard, Jean; Chargari, Cyrus; Mazal, Alejandro [Department of Radiation Oncology, Institut Curie, Paris (France); Kirov, Krassen [Department of Anesthesiology and Reanimation, Institut Curie, Paris (France)

    2012-07-01

    To assess clinical outcome of patients with pacemaker treated with thoracic radiation therapy for T8-T9 paravertebral chloroma. A 92-year-old male patient with chloroma presenting as paravertebral painful and compressive (T8-T9) mass was referred for radiotherapy in the Department of Radiation Oncology, Institut Curie. The patient presented with cardiac dysfunction and a permanent pacemaker that had been implanted prior. The decision of Multidisciplinary Meeting was to deliver 30 Gy in 10 fractions for reducing the symptoms and controlling the tumor growth. The patient received a total dose of 30 Gy in 10 fractions using 4-field conformal radiotherapy with 20-MV photons. The dose to pacemaker was 0.1 Gy but a part of the pacing leads was in the irradiation fields. The patient was treated the first time in the presence of his radiation oncologist and an intensive care unit doctor. Moreover, the function of his pacemaker was monitored during the entire radiotherapy course. No change in pacemaker function was observed during any of the radiotherapy fractions. The radiotherapy was very well tolerated without any side effects. The function of the pacemaker was checked before and after the radiotherapy treatment by the cardiologist and no pacemaker dysfunction was observed. Although updated guidelines are needed with acceptable dose criteria for implantable cardiac devices, it is possible to treat patients with these devices and parts encroaching on the radiation field. This case report shows we were able to safely treat our patient through a multidisciplinary approach, monitoring the patient during each step of the treatment.

  20. Temperature dependence of cardiac sarcoplasmic reticulum and sarcolemma in the ventricle of catfish (Clarias gariepinus

    Directory of Open Access Journals (Sweden)

    El-Sabry Abu-Amra

    2015-10-01

    The sarcolemmal Ca2+ contribution of activator Ca2+ was greater at a test temperature of 30 °C as assessed by verapamil. Whereas the SR-Ca2+ contribution was higher at 20 and 30 °C and a frequency rate of 0.2 and 0.4 Hz as assessed by caffeine and adrenaline, respectively. Bradykinin potentiating factor (BPF7 which was isolated from jelly fish (Cassiopea andromeda decreased the cardiac force developed at a frequency rate of 0.2 Hz and a temperature of 20 °C, whereas it increased the force developed at frequency rates of 0.2 and 0.4 Hz at 30 °C. These results indicate that BPF7 may act like verapamil in reducing the cardiac force through blocking the sarcolemmal Ca2+ channels at low temperature and like adrenaline in an increase of the cardiac force developed at warm temperature and the high frequency rate through stimulation of SR-Ca2+ activator. Therefore, this study indicates that the sarcolemmal Ca2+ influx and the SR-Ca2+ release contributors of activator Ca2+ for cardiac force development in the catfish heart were significantly greater at warm temperature and at the pacing frequency rates of 0.2 and 0.4 Hz as assessed by verapamil, adrenaline, caffeine and BPF7. However, the relative contribution of the sarcolemmal Ca2+ influx in the development of cardiac force in the catfish heart was greater than that of SR-Ca2+ release.

  1. Radiofrequency and microwave tumor ablation in patients with implanted cardiac devices: Is it safe?

    Energy Technology Data Exchange (ETDEWEB)

    Skonieczki, Brendan D., E-mail: bskonieczki@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Wells, Catherine, E-mail: cwells1@bidmc.harvard.edu [Department of Radiology, Harvard Medical School/Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Boston, MA 02215 (United States); Wasser, Elliot J., E-mail: ewasser@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert Medical School of Brown University/Rhode Island Hospital, 593 Eddy Street, Providence, RI 02903 (United States)

    2011-09-15

    Purpose: To identify malfunction of implanted cardiac devices during or after thermal ablation of tumors in lung, kidney, liver or bone, using radiofrequency (RF) or microwave (MW) energy. Materials and methods: After providing written consent, 19 patients (15 men and 4 women; mean age 78 years) with pacemakers or pacemaker/defibrillators underwent 22 CT image-guided percutaneous RF or MW ablation of a variety of tumors. Before and after each procedure, cardiac devices were interrogated and reprogrammed by a trained cardiac electrophysiology fellow. Possible pacer malfunctions included abnormalities on electrocardiographic (EKG) monitoring and alterations in device settings. Our institutional review board approved this Health Insurance Portability and Accountability Act-compliant study. Informed consent for participation in this retrospective study was deemed unnecessary by our review board. Results: During 20 of 22 sessions, no abnormalities were identified in continuous, EKG tracings or pacemaker functions. However, in two sessions significant changes, occurred in pacemaker parameters: inhibition of pacing during RF application in one, session and resetting of mode by RF energy in another session. These changes did not, result in hemodynamic instability of either patient. MW ablation was not associated with, any malfunction. In all 22 sessions, pacemakers were undamaged and successfully reset to original parameters. Conclusion: RF or MW ablation of tumors in liver, kidney, bone and lung can be performed safely in patients with permanent intra-cardiac devices, but careful planning between radiology and cardiology is essential to avoid adverse outcomes.

  2. On the pace of fertility decline in sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    David Shapiro

    2017-10-01

    Full Text Available Background: This descriptive finding examines the comparative pace of fertility decline in sub-Saharan Africa, relative to Asia, Latin America and the Caribbean, and Northern Africa. Objective: We seek to determine if fertility decline has been slower in sub-Saharan Africa than elsewhere in the developing world. Methods: United Nations 2017 estimates of national fertility are used in assessing the comparative pace of fertility decline, and the four regions are compared in terms of how far they are into their fertility transition. Results: The data shows clearly that fertility decline in sub-Saharan Africa, still at a comparatively early stage, has been considerably slower than the earlier declines in Asia, Latin America and the Caribbean, and Northern Africa at comparable stages of the transition, and displays less within-region heterogeneity than the transitions in these other regions. Conclusions: The slower pace of fertility decline in sub-Saharan Africa, in conjunction with the high current fertility levels in the region, means that in the absence of policies seeking to accelerate fertility decline, sub-Saharan Africa will continue to experience rapid population growth that in turn will constrain its development. Contribution: Presentation of data in a novel way (Figures 2‒4, and associated calculations unambiguously demonstrates the slow pace of fertility decline in sub-Saharan Africa compared with other regions of the world.

  3. International piping benchmarks: Use of simplified code PACE 2

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom)

    1979-06-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  4. International piping benchmarks: Use of simplified code PACE 2

    International Nuclear Information System (INIS)

    Boyle, J.; Spence, J.; Blundell, C.

    1979-01-01

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)

  5. Potenzielle Einflussfaktoren auf Pacing im ausdauersportlichen Wettkampf

    NARCIS (Netherlands)

    Thiel, C.; de Koning, J.J.; Foster, C.

    2015-01-01

    In competitive endurance sport, athletes permanently regulate their performance to achieve the best result without threatening organismic integrity. This conscious and subconscious allocation of energy reserves in relation to an endpoint is termed pacing and depends on sport-specific experience as

  6. Self-Paced Physics, Segments 19-23.

    Science.gov (United States)

    New York Inst. of Tech., Old Westbury.

    Five study segments of the Self-Paced Physics Course materials are presented in this fourth problems and solutions book used as a part of student course work. The subject matter is related to electric charges, insulators, Coulomb's law, electric fields, lines of force, solid angles, conductors, motion of charged particles, dipoles, electric flux,…

  7. Coupled iterated map models of action potential dynamics in a one-dimensional cable of cardiac cells

    International Nuclear Information System (INIS)

    Wang Shihong; Xie Yuanfang; Qu Zhilin

    2008-01-01

    Low-dimensional iterated map models have been widely used to study action potential dynamics in isolated cardiac cells. Coupled iterated map models have also been widely used to investigate action potential propagation dynamics in one-dimensional (1D) coupled cardiac cells, however, these models are usually empirical and not carefully validated. In this study, we first developed two coupled iterated map models which are the standard forms of diffusively coupled maps and overcome the limitations of the previous models. We then determined the coupling strength and space constant by quantitatively comparing the 1D action potential duration profile from the coupled cardiac cell model described by differential equations with that of the coupled iterated map models. To further validate the coupled iterated map models, we compared the stability conditions of the spatially uniform state of the coupled iterated maps and those of the 1D ionic model and showed that the coupled iterated map model could well recapitulate the stability conditions, i.e. the spatially uniform state is stable unless the state is chaotic. Finally, we combined conduction into the developed coupled iterated map model to study the effects of coupling strength on wave stabilities and showed that the diffusive coupling between cardiac cells tends to suppress instabilities during reentry in a 1D ring and the onset of discordant alternans in a periodically paced 1D cable

  8. The Jervell and Lange-Nielsen syndrome; atrial pacing combined with ß-blocker therapy, a favorable approach in young high-risk patients with long QT syndrome?

    Science.gov (United States)

    Früh, Andreas; Siem, Geir; Holmström, Henrik; Døhlen, Gaute; Haugaa, Kristina H

    2016-11-01

    Patients with Jervell and Lange-Nielsen syndrome (JLNS) exhibit severe phenotypes that are characterized by congenital deafness, very long QT intervals, and high risk of life-threatening arrhythmias. Current treatment strategies include high doses of beta-blocker medication, left cardiac sympathetic denervation, and ICD placement, which is challenging in young children. The purpose of this study was to evaluate the safety and effect of pacing in addition to beta-blocker treatment in children with JLNS. All genetically confirmed patients with JLNS born since 1999 in Norway were included in the study. Data on history of long QT syndrome-related symptoms, QT interval, and beta-blocker and pacemaker treatment were recorded. A total of 9 patients with QT intervals ranging from 510 to 660 ms were identified. Eight patients developed long QT syndrome-related symptoms, and 1 patient died before diagnosis. The survivors received beta-blocker medication. Seven patients also received a pacemaker; 1 had a ventricular lead and 6 had atrial leads. The patient with the ventricular lead died during follow-up. The 6 patients with atrial leads survived without events at a mean follow-up of 6.9 years after pacemaker implantation. Two patients received prophylactic upgrade to a 2-chamber ICD. No arrhythmic events occurred in 6 very young JLNS patients who received atrial pacing in combination with increased doses of beta-blockers during 7-year follow-up. If confirmed in additional patients, this treatment strategy may prevent life-threatening arrhythmias in this high-risk patient group and may act as a bridge to insertion of a 2-chamber ICD when left cardiac sympathetic denervation is not available. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  9. Effect of Head-Down Bed Rest and Artificial Gravity Countermeasure on Cardiac Autonomic and Advanced Electrocardiographic Function

    Science.gov (United States)

    Schlegel, T. T.; Platts, S.; Stenger, M.; Ribeiro, C.; Natapoff, A.; Howarth, M.; Evans, J.

    2007-01-01

    To study the effects of 21 days of head-down bed rest (HDBR), with versus without an artificial gravity (AG) countermeasure, on cardiac autonomic and advanced electrocardiographic function. Fourteen healthy men participated in the study: seven experienced 21 days of HDBR alone ("HDBR controls") and seven the same degree and duration of HDBR but with approximately 1hr daily short-arm centrifugation as an AG countermeasure ("AG-treated"). Five minute supine high-fidelity 12-lead ECGs were obtained in all subjects: 1) 4 days before HDBR; 2) on the last day of HDBR; and 3) 7 days after HDBR. Besides conventional 12-lead ECG intervals and voltages, all of the following advanced ECG parameters were studied: 1) both stochastic (time and frequency domain) and deterministic heart rate variability (HRV); 2) beat-to-beat QT interval variability (QTV); 3) T-wave morphology, including signal-averaged T-wave residua (TWR) and principal component analysis ratios; 4) other SAECG-related parameters including high frequency QRS ECG and late potentials; and 5) several advanced ECG estimates of left ventricular (LV) mass. The most important results by repeated measures ANOVA were that: 1) Heart rates, Bazett-corrected QTc intervals, TWR, LF/HF power and the alpha 1 of HRV were significantly increased in both groups (i.e., by HDBR), but with no relevant HDBR*group differences; 2) All purely "vagally-mediated" parameters of HRV (e.g., RMSSD, HF power, Poincare SD1, etc.), PR intervals, and also several parameters of LV mass (Cornell and Sokolow-Lyon voltages, spatial ventricular activation times, ventricular gradients) were all significantly decreased in both groups (i.e., by HDBR), but again with no relevant HDBR*group differences); 3) All "generalized" or "vagal plus sympathetic" parameters of stochastic HRV (i.e., SDNN, total power, LF power) were significantly more decreased in the AG-treated group than in the HDBR-only group (i.e., here there was a relevant HDBR*group difference

  10. Atrioventricular and ventricular-to-ventricular programming in patients with cardiac resynchronization therapy: results from ALTITUDE.

    Science.gov (United States)

    Steinberg, Benjamin A; Wehrenberg, Scott; Jackson, Kevin P; Hayes, David L; Varma, Niraj; Powell, Brian D; Day, John D; Frazier-Mills, Camille G; Stein, Kenneth M; Jones, Paul W; Piccini, Jonathan P

    2015-12-01

    Cardiac resynchronization therapy (CRT) improves outcomes in patients with heart failure, yet response rates are variable. We sought to determine whether physician-specified CRT programming was associated with improved outcomes. Using data from the ALTITUDE remote follow-up cohort, we examined sensed atrioventricular (AV) and ventricular-to-ventricular (VV) programming and their associated outcomes in patients with de novo CRT from 2009-2010. Outcomes included arrhythmia burden, left ventricular (LV) pacing, and all-cause mortality at 4 years. We identified 5709 patients with de novo CRT devices; at the time of implant, 34% (n = 1959) had entirely nominal settings programmed, 40% (n = 2294) had only AV timing adjusted, 11% (n = 604) had only VV timing adjusted, and 15% (n = 852) had both AV and VV adjusted from nominal programming. Suboptimal LV pacing (5% was lowest in the AV-only adjusted group (17.9%) and highest in the nominal (27.7%) and VV-only adjusted (28.3%) groups. Adjusted all-cause mortality was significantly higher among patients with non-nominal AV delay >120 vs. 180 vs. ≤180 ms, p = 0.4). Nominal settings for de novo CRT implants are frequently altered, most commonly the AV delay. There is wide variability in reprogramming. Patients with nominal or AV-only adjustments appear to have favorable pacing and arrhythmia outcomes. Sensed AV delays less than 120 ms are associated with improved survival.

  11. The effects of presentation pace and modality on learning a multimedia science lesson

    Science.gov (United States)

    Chung, Wen-Hung

    Working memory is a system that consists of multiple components. The visuospatial sketchpad is the main entrance for visual and spatial information, whereas acoustic and verbal information is processed in the phonological loop. The central executive works as a coordinator of information from these two subsystems. Numerous studies have shown that working memory has a very limited capacity. Based on these characteristics of working memory, theories such as cognitive load theory and the cognitive theory of multimedia learning provide multimedia design principles. One of these principles is that when verbal information accompanying pictures is presented in audio mode instead of visually, learning can be more effective than if both text and pictures are presented visually. This is called the modality effect. However, some studies have found that the modality effect does not occur in some situations. In most experiments examining the modality effect, the multimedia is presented as system-paced. If learners are able to repeat listening as many times as they need, the superiority of spoken text over visual text seems lessened. One aim of this study was to examine the modality effect in a learner-controlled condition. This study also used the one-word-at-a-time technique to investigate whether the modality effect would still occur if both reading and listening rates were equal. There were 182 college students recruited for this study. Participants were randomly assigned to seven groups: a self-paced listening group, a self-paced reading group, a self text-block reading group, a general-paced listening group, a general-paced reading group, a fast-paced listening group, and a fast-paced reading group. The experimental material was a cardiovascular multimedia module. A three-by-two between-subjects design was used to test the main effect. Results showed that modality effect was still present but not between the self-paced listening group and the self text-block reading group

  12. Thoracoscopic patch insulation to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy.

    Science.gov (United States)

    Mediratta, Neeraj; Barker, Diane; McKevith, James; Davies, Peter; Belchambers, Sandra; Rao, Archana

    2012-07-01

    Cardiac resynchronization therapy is an established therapy for heart failure, improving quality of life and prognosis. Despite advances in technique, available leads and delivery systems, trans-venous left ventricular (LV) lead positioning remains dependent on the patient's underlying venous anatomy. The left phrenic nerve courses over the surface of the pericardium laterally and may be stimulated by the LV pacing lead, causing uncomfortable diaphragmatic twitch. This paper describes a video-assisted thoracoscopic (VATS) procedure to correct phrenic nerve stimulation secondary to cardiac resynchronization therapy. Most current ways of avoiding phrenic stimulation involve either electronic reprogramming to distance the phrenic nerve from the stimulation circuit or repositioning the lead. We describe a case where the phrenic nerve was surgically insulated from the stimulating current by insinuating a patch of bovine pericardium between the epicardium and native pericardium of the heart thus completely resolving previously intolerable and incessant diaphragmatic twitch. The procedure was performed under general anaesthesia with single-lung ventilation and minimal use of neuromuscular blocking agents. Surgical patch insulation of the phrenic nerve was performed using minimally invasive VATS surgery, as a short-stay procedure, with no complications. No diaphragmatic twitch occurred post-surgery and the patient continued to gain symptomatic benefit from cardiac synchronization therapy (New York Heart Association Class III to II), enabling return to work. In cases where the trans-venous position of a LV lead is limited by troublesome phrenic nerve stimulation, thoracoscopic surgical patch insulation of the phrenic nerve could be considered to allow beneficial cardiac resynchronization therapy.

  13. Machine Learning of Human Pluripotent Stem Cell-Derived Engineered Cardiac Tissue Contractility for Automated Drug Classification

    Directory of Open Access Journals (Sweden)

    Eugene K. Lee

    2017-11-01

    Full Text Available Accurately predicting cardioactive effects of new molecular entities for therapeutics remains a daunting challenge. Immense research effort has been focused toward creating new screening platforms that utilize human pluripotent stem cell (hPSC-derived cardiomyocytes and three-dimensional engineered cardiac tissue constructs to better recapitulate human heart function and drug responses. As these new platforms become increasingly sophisticated and high throughput, the drug screens result in larger multidimensional datasets. Improved automated analysis methods must therefore be developed in parallel to fully comprehend the cellular response across a multidimensional parameter space. Here, we describe the use of machine learning to comprehensively analyze 17 functional parameters derived from force readouts of hPSC-derived ventricular cardiac tissue strips (hvCTS electrically paced at a range of frequencies and exposed to a library of compounds. A generated metric is effective for then determining the cardioactivity of a given drug. Furthermore, we demonstrate a classification model that can automatically predict the mechanistic action of an unknown cardioactive drug.

  14. Variables affecting the manifestation of and intensity of pacing behavior: A preliminary case study in zoo-housed polar bears.

    Science.gov (United States)

    Cless, Isabelle T; Lukas, Kristen E

    2017-09-01

    High-speed video analysis was used to quantify two aspects of gait in 10 zoo-housed polar bears. These two variables were then examined as to how they differed in the conditions of pacing versus locomoting for each bear. Percent difference calculations measured the difference between pacing and locomoting data for each bear. We inferred that the higher the percent difference between pacing and locomoting in a given subject, the more intense the pacing may be. The percent difference values were analyzed alongside caregiver survey data defining the locations, frequency, and anticipatory nature of pacing in each bear, as well as each bear's age and sex, to determine whether any variables were correlated. The frequency and intensity of pacing behavior were not correlated. However, location of pacing was significantly correlated both with the subjects' age and whether or not the subject was classified as an anticipatory pacer. Bears appeared to select specific spots within their exhibits to pace, and the location therefore seemed tied to underlying motivation for the behavior. Additionally, bears that were classified in the survey as pacing anticipatorily displayed significantly more intense pacing behavior as quantified by gait analysis. © 2017 Wiley Periodicals, Inc.

  15. Artificial intelligence in medicine and cardiac imaging: harnessing big data and advanced computing to provide personalized medical diagnosis and treatment.

    Science.gov (United States)

    Dilsizian, Steven E; Siegel, Eliot L

    2014-01-01

    Although advances in information technology in the past decade have come in quantum leaps in nearly every aspect of our lives, they seem to be coming at a slower pace in the field of medicine. However, the implementation of electronic health records (EHR) in hospitals is increasing rapidly, accelerated by the meaningful use initiatives associated with the Center for Medicare & Medicaid Services EHR Incentive Programs. The transition to electronic medical records and availability of patient data has been associated with increases in the volume and complexity of patient information, as well as an increase in medical alerts, with resulting "alert fatigue" and increased expectations for rapid and accurate diagnosis and treatment. Unfortunately, these increased demands on health care providers create greater risk for diagnostic and therapeutic errors. In the near future, artificial intelligence (AI)/machine learning will likely assist physicians with differential diagnosis of disease, treatment options suggestions, and recommendations, and, in the case of medical imaging, with cues in image interpretation. Mining and advanced analysis of "big data" in health care provide the potential not only to perform "in silico" research but also to provide "real time" diagnostic and (potentially) therapeutic recommendations based on empirical data. "On demand" access to high-performance computing and large health care databases will support and sustain our ability to achieve personalized medicine. The IBM Jeopardy! Challenge, which pitted the best all-time human players against the Watson computer, captured the imagination of millions of people across the world and demonstrated the potential to apply AI approaches to a wide variety of subject matter, including medicine. The combination of AI, big data, and massively parallel computing offers the potential to create a revolutionary way of practicing evidence-based, personalized medicine.

  16. Optimizing classroom instruction through self-paced learning prototype

    Directory of Open Access Journals (Sweden)

    Romiro Gordo Bautista

    2015-09-01

    Full Text Available This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students’ learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was conducted, scored and analyzed which served as the basis in determining the initial learning schema of the respondents. A questionnaire was adopted to find the learning motivation of the students in science. Using Pearson-r correlation, it was found out that there is a highly significant relationship between their internal drive and their academic performance. Moreover, a post-test was conducted after self-paced learning prototype was used in the development of select topics in their curricular plot. It was found out that the students who experienced the self-paced learning prototype performed better in their academic performance as evidenced by the difference of their mean post-test results. ANCOVA results on the post-test mean scores of the respondents were utilized in establishing the causal-effect of the learning prototype to the academic performance of the students in Chemistry. A highly significant effect on their academic performance (R-square value of 70.7% and significant interaction of the models to the experimental grouping and mental abilities of the respondents are concluded in the study.

  17. Species-dependent adaptation of the cardiac Na+/K+ pump kinetics to the intracellular Na+ concentration.

    Science.gov (United States)

    Lewalle, Alexandre; Niederer, Steven A; Smith, Nicolas P

    2014-12-15

    The Na(+)/K(+) ATPase (NKA) plays a critical role in maintaining ionic homeostasis and dynamic function in cardiac myocytes, within both the in vivo cell and in silico models. Physiological conditions differ significantly between mammalian species. However, most existing formulations of NKA used to simulate cardiac function in computational models are derived from a broad range of experimental sources spanning many animal species. The resultant inability of these models to discern species-specific features is a significant obstacle to achieving a detailed quantitative and comparative understanding of physiological behaviour in different biological contexts. Here we present a framework for characterising the steady-state NKA current using a biophysical mechanistic model specifically designed to provide a mechanistic explanation of the NKA flux supported by self-consistent species-specific data. We thus compared NKA kinetics specific to guinea- pig and rat ventricular myocytes. We observe that the apparent binding affinity for sodium in the rat is significantly lower, whereas the overall pump cycle rate is doubled, in comparison to the guinea pig. This sensitivity of NKA to its regulatory substrates compensates for the differences in Na(+) concentrations between the cell types. NKA is thereby maintained within its dynamic range over a wide range of pacing frequencies in these two species, despite significant disparities in sodium concentration. Hence, by replacing a conventional generic NKA model with our rat-specific NKA formula into a whole-cell simulation, we have, for the first time, been able to accurately reproduce the action potential duration and the steady-state sodium concentration as functions of pacing frequency. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  18. Improved cardiac filling facilitates the postprandial elevation of stroke volume in Python regius.

    Science.gov (United States)

    Enok, Sanne; Leite, Gabriella S P C; Leite, Cléo A C; Gesser, Hans; Hedrick, Michael S; Wang, Tobias

    2016-10-01

    To accommodate the pronounced metabolic response to digestion, pythons increase heart rate and elevate stroke volume, where the latter has been ascribed to a massive and fast cardiac hypertrophy. However, numerous recent studies show that heart mass rarely increases, even upon ingestion of large meals, and we therefore explored the possibility that a rise in mean circulatory filling pressure (MCFP) serves to elevate venous pressure and cardiac filling during digestion. To this end, we measured blood flows and pressures in anaesthetized Python regius The anaesthetized snakes exhibited the archetypal tachycardia as well as a rise in both venous pressure and MCFP that fully account for the approximate doubling of stroke volume. There was no rise in blood volume and the elevated MCFP must therefore stem from increased vascular tone, possibly by means of increased sympathetic tone on the veins. Furthermore, although both venous pressure and MCFP increased during volume loading, there was no evidence that postprandial hearts were endowed with an additional capacity to elevate stroke volume. In vitro measurements of force development of paced ventricular strips also failed to reveal signs of increased contractility, but the postprandial hearts had higher activities of cytochrome oxidase and pyruvate kinase, which probably serves to sustain the rise in cardiac work during digestion. © 2016. Published by The Company of Biologists Ltd.

  19. Racing an Opponent Alters Pacing, Performance and Muscle Force Decline, But Not RPE

    NARCIS (Netherlands)

    Konings, Marco J; Parkinson, Jordan; Zijdewind, Inge; Hettinga, Florentina

    PURPOSE: Performing against a virtual opponent has been shown to invite a change in pacing and improve time trial (TT) performance. This study explored how this performance improvement is established by assessing changes in pacing, neuromuscular function and perceived exertion. METHODS: After a peak

  20. Prevalence of conduction delay of the right atrium in patients with SSS: implications for pacing site selection.

    Science.gov (United States)

    Verlato, Roberto; Zanon, Francesco; Bertaglia, Emanuele; Turrini, Pietro; Baccillieri, Maria Stella; Baracca, Enrico; Bongiorni, Maria Grazia; Zampiero, Aldo; Zonzin, Pietro; Pascotto, Pietro; Venturini, Diego; Corbucci, Giorgio

    2007-09-01

    To evaluate the prevalence of severe right atrial conduction delay in patients with sinus node dysfunction (SND) and atrial fibrillation (AF) and the effects of pacing in the right atrial appendage (RAA) and in the inter-atrial septum (IAS). Forty-two patients (15 male, 72 +/- 7 years) underwent electrophysiologic study to measure the difference between the conduction time from RAA to coronary sinus ostium during stimulation at 600 ms and after extrastimulus (DeltaCTos). Patients were classified as group A if DeltaCTos > 60 ms and group B if IAS pacing and algorithms ON/OFF. Fifteen patients (36%, group A) had DeltaCTos = 76 +/- 11 ms and 27 patients (64%, group B) had DeltaCTos = 36 +/- 20 ms. Twenty-two patients were paced at the RAA and 20 at the IAS. During the study, no AF recurrences were reported in 11 of 42 (26%) patients, independently of RAA or IAS pacing. Patients from group A and RAA pacing had 0.79 +/- 0.81 episodes of AF/day during DDD, which increased to 1.52 +/- 1.41 episodes of AF/day during DDDR + Alg (P = 0.046). Those with IAS pacing had 0.5 +/- 0.24 episodes of AF/day during DDD, which decreased to 0.06 +/- 0.08 episodes of AF/day during DDDR + Alg (P = 0.06). In group B, no differences were reported between pacing sites and pacing modes. Severe right atrial conduction delay is present in one-third of patients with SND and AF: continuous pacing at the IAS is superior to RAA for AF recurrences. In patients without severe conduction delay, no differences between pacing site or mode were observed.

  1. Even between-lap pacing despite high within-lap variation during mountain biking.

    Science.gov (United States)

    Martin, Louise; Lambeth-Mansell, Anneliese; Beretta-Azevedo, Liane; Holmes, Lucy A; Wright, Rachel; St Clair Gibson, Alan

    2012-09-01

    Given the paucity of research on pacing strategies during competitive events, this study examined changes in dynamic high-resolution performance parameters to analyze pacing profiles during a multiple-lap mountain-bike race over variable terrain. A global-positioning-system (GPS) unit (Garmin, Edge 305, USA) recorded velocity (m/s), distance (m), elevation (m), and heart rate at 1 Hz from 6 mountain-bike riders (mean±SD age=27.2±5.0 y, stature=176.8±8.1 cm, mass=76.3±11.7 kg, VO2max=55.1±6.0 mL·kg(-1)·min1) competing in a multilap race. Lap-by-lap (interlap) pacing was analyzed using a 1-way ANOVA for mean time and mean velocity. Velocity data were averaged every 100 m and plotted against race distance and elevation to observe the presence of intralap variation. There was no significant difference in lap times (P=.99) or lap velocity (P=.65) across the 5 laps. Within each lap, a high degree of oscillation in velocity was observed, which broadly reflected changes in terrain, but high-resolution data demonstrated additional nonmonotonic variation not related to terrain. Participants adopted an even pace strategy across the 5 laps despite rapid adjustments in velocity during each lap. While topographical and technical variations of the course accounted for some of the variability in velocity, the additional rapid adjustments in velocity may be associated with dynamic regulation of self-paced exercise.

  2. Battery longevity in cardiac resynchronization therapy implantable cardioverter defibrillators.

    Science.gov (United States)

    Alam, Mian Bilal; Munir, Muhammad Bilal; Rattan, Rohit; Flanigan, Susan; Adelstein, Evan; Jain, Sandeep; Saba, Samir

    2014-02-01

    Cardiac resynchronization therapy (CRT) implantable cardioverter defibrillators (ICDs) deliver high burden ventricular pacing to heart failure patients, which has a significant effect on battery longevity. The aim of this study was to investigate whether battery longevity is comparable for CRT-ICDs from different manufacturers in a contemporary cohort of patients. All the CRT-ICDs implanted at our institution from 1 January 2008 to 31 December 2010 were included in this analysis. Baseline demographic and clinical data were collected on all patients using the electronic medical record. Detailed device information was collected on all patients from scanned device printouts obtained during routine follow-up. The primary endpoint was device replacement for battery reaching the elective replacement indicator (ERI). A total of 646 patients (age 69 ± 13 years), implanted with CRT-ICDs (Boston Scientific 173, Medtronic 416, and St Jude Medical 57) were included in this analysis. During 2.7 ± 1.5 years follow-up, 113 (17%) devices had reached ERI (Boston scientific 4%, Medtronic 25%, and St Jude Medical 7%, P battery was significantly worse for Medtronic devices compared with devices from other manufacturers (94% for Boston scientific, 67% for Medtronic, and 92% for St Jude Medical, P battery longevity by manufacturer was independent of pacing burden, lead parameters, and burden of ICD therapy. There are significant discrepancies in CRT-ICD battery longevity by manufacturer. These data have important implications on clinical practice and patient outcomes.

  3. Perioperative period in cardiac transplantation from donors with brain death due to methanol poisoning

    Directory of Open Access Journals (Sweden)

    V. N. Poptsov

    2017-01-01

    Full Text Available The successful use of donor hearts from people died of methanol poisoning helps reducing the deficit of donor organs for patients requiring urgent cardiac transplantation [3]. We present our experience of successful cardiac transplantations from 2 donors who died due to methanol poisoning. Given the possibility of performing a cardiac transplant from this group of donors a protocol has been developed at the V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs of the Ministry of Healthcare of the Russian Federation which includes clinical, laboratory and instrumental criteria for the selection of heart donor and recipient. The possibility of delayed onset myocardial contractile dysfunction due to methanol poisoning means that a longer conditioningperiod is vital as well as compulsory clinical, laboratory and expert chocardiographic examinations of the potential donor heart.

  4. Amplify scientific discovery with artificial intelligence

    Energy Technology Data Exchange (ETDEWEB)

    Gil, Yolanda; Greaves, Mark T.; Hendler, James; Hirsch, Hyam

    2014-10-10

    Computing innovations have fundamentally changed many aspects of scientific inquiry. For example, advances in robotics, high-end computing, networking, and databases now underlie much of what we do in science such as gene sequencing, general number crunching, sharing information between scientists, and analyzing large amounts of data. As computing has evolved at a rapid pace, so too has its impact in science, with the most recent computing innovations repeatedly being brought to bear to facilitate new forms of inquiry. Recently, advances in Artificial Intelligence (AI) have deeply penetrated many consumer sectors, including for example Apple’s Siri™ speech recognition system, real-time automated language translation services, and a new generation of self-driving cars and self-navigating drones. However, AI has yet to achieve comparable levels of penetration in scientific inquiry, despite its tremendous potential in aiding computers to help scientists tackle tasks that require scientific reasoning. We contend that advances in AI will transform the practice of science as we are increasingly able to effectively and jointly harness human and machine intelligence in the pursuit of major scientific challenges.

  5. Hemodynamic deterioration during extracorporeal membrane oxygenation weaning in a patient with a total artificial heart.

    Science.gov (United States)

    Hosseinian, Leila; Levin, Matthew A; Fischer, Gregory W; Anyanwu, Anelechi C; Torregrossa, Gianluca; Evans, Adam S

    2015-01-01

    The Total Artificial Heart (Syncardia, Tucson, AZ) is approved for use as a bridge-to-transplant or destination therapy in patients who have irreversible end-stage biventricular heart failure. We present a unique case, in which the inferior vena cava compression by a total artificial heart was initially masked for days by the concurrent placement of an extracorporeal membrane oxygenation cannula. This is the case of a 33-year-old man admitted to our institution with recurrent episodes of ventricular tachycardia requiring emergent total artificial heart and venovenous extracorporeal membrane oxygenation placement. This interesting scenario highlights the importance for critical care physicians to have an understanding of exact anatomical localization of a total artificial heart, extracorporeal membrane oxygenation, and their potential interactions. In total artificial heart patients with hemodynamic compromise or reduced device filling, consideration should always be given to venous inflow compression, particularly in those with smaller body surface area. Transesophageal echocardiogram is a readily available diagnostic tool that must be considered standard of care, not only in the operating room but also in the ICU, when dealing with this complex subpopulation of cardiac patients.

  6. Merits and limitations of the mode switching rate stabilization pacing algorithms in the implantable cardioverter defibrillator.

    Science.gov (United States)

    Dijkman, B; Wellens, H J

    2001-09-01

    The 7250 Jewel AF Medtronic model of ICD is the first implantable device in which both therapies for atrial arrhythmias and pacing algorithms for atrial arrhythmia prevention are available. Feasibility of that extensive atrial arrhythmia management requires correct and synergic functioning of different algorithms to control arrhythmias. The ability of the new pacing algorithms to stabilize the atrial rate following termination of treated atrial arrhythmias was evaluated in the marker channel registration of 600 spontaneously occurring episodes in 15 patients with the Jewel AF. All patients (55+/-15 years) had structural heart disease and documented atrial and ventricular arrhythmias. Dual chamber rate stabilization pacing was present in 245 (41 %) of episodes following arrhythmia termination and was a part of the mode switching operation during which pacing was provided in the dynamic DDI mode. This algorithm could function as the atrial rate stabilization pacing only when there was a slow spontaneous atrial rhythm or in presence of atrial premature beats conducted to the ventricles with a normal AV time. In case of atrial premature beats with delayed or absent conduction to the ventricles and in case of ventricular premature beats, the algorithm stabilized the ventricular rate. The rate stabilization pacing in DDI mode during sinus rhythm following atrial arrhythmia termination was often extended in time due to the device-based definition of arrhythmia termination. This was also the case in patients, in whom the DDD mode with true atrial rate stabilization algorithm was programmed. The rate stabilization algorithms in the Jewel AF applied after atrial arrhythmia termination provide pacing that is not based on the timing of atrial events. Only under certain circumstances the algorithm can function as atrial rate stabilization pacing. Adjustments in availability and functioning of the rate stabilization algorithms might be of benefit for the clinical performance of

  7. A Closer Look at Split Visual Attention in System- and Self-Paced Instruction in Multimedia Learning

    Science.gov (United States)

    Schmidt-Weigand, Florian; Kohnert, Alfred; Glowalla, Ulrich

    2010-01-01

    Two experiments examined visual attention distribution in learning from text and pictures. Participants watched a 16-step multimedia instruction on the formation of lightning. In Experiment 1 (N=90) the instruction was system-paced (fast, medium, slow pace), while it was self-paced in Experiment 2 (N=31). In both experiments the text modality was…

  8. Infants' Visual Attention to Baby DVDs as a Function of Program Pacing

    Science.gov (United States)

    Gola, Alice Ann Howard; Calvert, Sandra L.

    2011-01-01

    This study examined the effects of program pacing, defined as the rate of scene and character change per minute, on infants' visual attention to video presentations. Seventy-two infants (twenty-four 6-month-olds, twenty-four 9-month-olds, twenty-four 12-month-olds) were exposed to one of two sets of high- and low-paced commercial infant DVDs. Each…

  9. Cardiac supporting device using artificial rubber muscle: preliminary study to active dynamic cardiomyoplasty.

    Science.gov (United States)

    Saito, Yoshiaki; Suzuki, Yasuyuki; Goto, Takeshi; Daitoku, Kazuyuki; Minakawa, Masahito; Fukuda, Ikuo

    2015-12-01

    Dynamic cardiomyoplasty is a surgical treatment that utilizes the patient's skeletal muscle to support circulation. To overcome the limitations of autologous skeletal muscles in dynamic cardiomyoplasty, we studied the use of a wrapped-type cardiac supporting device using pneumatic muscles. Four straight rubber muscles (Fluidic Muscle, FESTO, Esslingen, Germany) were used and connected to pressure sensors, solenoid valves, a controller and an air compressor. The driving force was compressed air. A proportional-integral-derivative system was employed to control the device movement. An overflow-type mock circulation system was used to analyze the power and the controllability of this new device. The device worked powerfully with pumped flow against afterload of 88 mmHg, and the beating rate and contraction/dilatation time were properly controlled using simple software. Maximum pressure inside the ventricle and maximum output were 187 mmHg and 546.5 ml/min, respectively, in the setting of 50 beats per minute, a contraction/dilatation ratio of 1:2, a preload of 18 mmHg, and an afterload of 88 mmHg. By changing proportional gain, contraction speed could be modulated. This study showed the efficacy and feasibility of a pneumatic muscle for use in a cardiac supporting device.

  10. Interatrial septum versus right atrial appendage pacing for prevention of atrial fibrillation : A meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Zhang, L; Jiang, H; Wang, W; Bai, J; Liang, Y; Su, Y; Ge, J

    2017-07-28

    Interatrial septum (IAS) pacing seems to be a promising strategy for the prevention of atrial fibrillation (AF); however, studies have yielded conflicting results. This meta-analysis was to compare IAS with right atrial appendage (RAA) pacing on the prevention of postpacing AF occurrence. Pubmed, MEDLINE, EMBASE and Web of Science databases were searched through October 2016 for randomized controlled trials comparing IAS with RAA pacing on the prevention of AF. Data concerning study design, patient characteristics and outcomes were extracted. Risk ratio (RR), weighted mean differences (WMD) or standardized mean differences (SMD) were calculated using fixed or random effects models. A total of 12 trials involving 1146 patients with dual-chamber pacing were included. Although IAS was superior to RAA pacing in terms of reducing the number of AF episodes (SMD = -0.29, P = 0.05), AF burden (SMD = -0.41, P = 0.008) and P -wave duration (WMD = -34.45 ms, P IAS pacing. Nevertheless, no differences were observed concerning all-cause death (RR = 1.04, P = 0.88), procedure-related events (RR = 1.17, P = 0.69) and pacing parameters between IAS and RAA pacing in the follow-up period. IAS pacing is safe and as well tolerated as RAA pacing. Although IAS pacing may fail to prevent permanent AF occurrence and recurrences of AF, it is able to not only improve interatrial conduction, but also reduce AF burden.

  11. Application of artificial removal networks to estimation of the left-to-right cardiac or ductal shunts. Pt. 1. Studies on idealized mathematically created pulmonary radioangiograms

    International Nuclear Information System (INIS)

    Rudzki, K.; Rudzka, J.; Nowak, S.; Sadowski, T.; Czogala, E.

    1995-01-01

    The purpose of these studies was to examine usefulness of the artificial neural network for classification of the left-to-right cardiac or ductal shunt intensity. Our own program of stimulation of three-layer neural network was used. Studies were carried out on three series of mathematically created, idealized curves. Effect of changing the numbers of neural network processing elements on learning and recognition procedures was examined. There was a relation of the number of the rounds necessary to train up the net to the number of classes according to the shunt size (Qp/Qs) and to the number of curves in each class of training series. Using of learning series containing more curves in each class improves the ability to classification of curves by a trained-up neural network. Reducing the input data to 24 points of the down slope of the curve improves the learning ability of the network and classification of the radioangiograms. These studies suggest that the neural networks could be a useful tool of classification of pulmonary radioangiograms. (author). 2 figs, 4 tabs

  12. PACES: A Model of Student Well-Being

    Science.gov (United States)

    Nelson, Mark D.; Tarabochia, Dawn W.; Koltz, Rebecca L.

    2015-01-01

    School counselors design, deliver, and evaluate comprehensive, developmental school counseling programs that are focused on enhancing student development and success. A model of student well-being, known as PACES, is defined and described that consists of five distinct and interactive domains: physical, affective, cognitive, economic, and social.…

  13. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking

    Science.gov (United States)

    Buhmann, Jeska; Desmet, Frank; Moens, Bart; Van Dyck, Edith; Leman, Marc

    2016-01-01

    The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended) synchronization. But is this velocity effect still present with non-instructed (spontaneous) synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities. PMID:27167064

  14. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking.

    Science.gov (United States)

    Buhmann, Jeska; Desmet, Frank; Moens, Bart; Van Dyck, Edith; Leman, Marc

    2016-01-01

    The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended) synchronization. But is this velocity effect still present with non-instructed (spontaneous) synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities.

  15. Spontaneous Velocity Effect of Musical Expression on Self-Paced Walking.

    Directory of Open Access Journals (Sweden)

    Jeska Buhmann

    Full Text Available The expressive features of music can influence the velocity of walking. So far, studies used instructed (and intended synchronization. But is this velocity effect still present with non-instructed (spontaneous synchronization? To figure that out, participants were instructed to walk in their own comfort tempo on an indoor track, first in silence and then with tempo-matched music. We compared velocities of silence and music conditions. The results show that some music has an activating influence, increasing velocity and motivation, while other music has a relaxing influence, decreasing velocity and motivation. The influence of musical expression on the velocity of self-paced walking can be predicted with a regression model using only three sonic features explaining 56% of the variance. Phase-coherence between footfall and beat did not contribute to the velocity effect, due to its implied fixed pacing. The findings suggest that the velocity effect depends on vigor entrainment that influences both stride length and pacing. Our findings are relevant for preventing injuries, for gait improvement in walking rehabilitation, and for improving performance in sports activities.

  16. Metabolic Responses and Pacing Strategies during Successive Sprint Skiing Time Trials

    DEFF Research Database (Denmark)

    Andersson, Erik; Holmberg, Hans-Christer; Ørtenblad, Niels

    2016-01-01

    PURPOSE: To examine the metabolic responses and pacing strategies during the performance of successive sprint time trials (STTs) in cross-country skiing. METHODS: Ten well-trained male cross-country skiers performed four self-paced 1300-m STTs on a treadmill, each separated by 45 min of recovery...... to estimate the anaerobic energy supply. RESULTS: The individual trial-to-trial variability in STT performance time was 1.3%, where variations in O2 deficit and V˙O2 explained 69% (P 0.05) of the variation in performance. The first and last STTs were equally fast (228 ± 10 s), and ~ 1...... on the first than second course half. In addition, metabolic rates were substantially higher (~_30%) for uphill than for flat skiing, indicating that pacing was regulated to the terrain. CONCLUSIONS: The fastest STTs were characterized primarily by a greater anaerobic energy production, which also explained 69...

  17. Acquired tricuspid valve stenosis associated with two ventricular endocardial pacing leads in a dog.

    Science.gov (United States)

    Tompkins, Emily; Dulake, Michelle I; Ghaffari, Shadie; Nakamura, Reid K

    2015-01-01

    Acquired tricuspid valve stenosis (TVS) is a rare complication of endocardial pacing lead implantation in humans that has only been described once previously in the veterinary literature in a dog with excessive lead redundancy. A 12 yr old terrier presented with right-sided congestive heart failure 6 mo after implantation of a second ventricular endocardial pacing lead. The second lead was placed due to malfunction of the first lead, which demonstrated abnormally low impedance. Transthoracic echocardiography identified hyperechoic tissue associated with the pacing leads as they crossed the tricuspid valve annulus as well as a stenotic tricuspid inflow pattern via spectral Doppler interrogation. Medical management was ultimately unsuccessful and the dog was euthanized 6 wk after TVS was diagnosed. The authors report the first canine case of acquired TVS associated with two ventricular endocardial pacing leads.

  18. Value of the New Spline QTc Formula in Adjusting for Pacing-Induced Changes in Heart Rate

    Directory of Open Access Journals (Sweden)

    Hirmand Nouraei

    2018-01-01

    Full Text Available Aims. To determine whether a new QTc calculation based on a Spline fit model derived and validated from a large population remained stable in the same individual across a range of heart rates (HRs. Second, to determine whether this formula incorporating QRS duration can be of value in QT measurement, compared to direct measurement of the JT interval, during ventricular pacing. Methods. Individuals (N=30; 14 males aged 51.9 ± 14.3 years were paced with decremental atrial followed by decremental ventricular pacing. Results. The new QTc changed minimally with shorter RR intervals, poorly fit even a linear relationship, and did not fit a second-order polynomial. In contrast, the Bazett formula (QTcBZT showed a steep and marked increase in QTc with shorter RR intervals. For atrial pacing data, QTcBZT was fit best by a second-order polynomial and demonstrated a dramatic increase in QTc with progressively shorter RR intervals. For ventricular pacing, the new QTc minus QRS duration did not meaningfully change with HR in contrast to the HR dependency of QTcBZT and JT interval. Conclusion. The new QT correction formula is minimally impacted by HR acceleration induced by atrial or ventricular pacing. The Spline QTc minus QRS duration is an excellent method to estimate QTc in ventricular paced complexes.

  19. Optimal pacing for right ventricular and biventricular devices: minimizing, maximizing, and right ventricular/left ventricular site considerations.

    Science.gov (United States)

    Gillis, Anne M

    2014-10-01

    The results from numerous clinical studies provide guidance for optimizing outcomes related to RV or biventricular pacing in the pacemaker and ICD populations. (1) Programming algorithms to minimize RV pacing is imperative in patients with dual-chamber pacemakers who have intrinsic AV conduction or intermittent AV conduction block. (2) Dual-chamber ICDs should be avoided in candidates without an indication for bradycardia pacing. (3) Alternate RV septal pacing sites may be considered at the time of pacemaker implantation. (4) Biventricular pacing may be beneficial in some patients with mild LV dysfunction. (5) LV lead placement at the site of latest LV activation is desirable. (6) Programming CRT systems to achieve biventricular/LV pacing >98.5% is important. (7) Protocols for AV and VV optimization in patients with CRT are not recommended after device implantation but may be considered for CRT nonresponders. (8) Novel algorithms to maximize the benefit of CRT are in evolution further.

  20. Neuro-prosthetic interplay. Comment on "Hand synergies: Integration of robotics and neuroscience for understanding the control of biological and artificial hands" by M. Santello et al.

    Science.gov (United States)

    Schieber, Marc H.

    2016-07-01

    Control of the human hand has been both difficult to understand scientifically and difficult to emulate technologically. The article by Santello and colleagues in the current issue of Physics of Life Reviews[1] highlights the accelerating pace of interaction between the neuroscience of controlling body movement and the engineering of robotic hands that can be used either autonomously or as part of a motor neuroprosthesis, an artificial body part that moves under control from a human subject's own nervous system. Motor neuroprostheses typically involve a brain-computer interface (BCI) that takes signals from the subject's nervous system or muscles, interprets those signals through a decoding algorithm, and then applies the resulting output to control the artificial device.

  1. Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, J.

    2010-06-01

    Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate a commitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV in PACE programs.

  2. Cardiac regeneration therapy: connections to cardiac physiology.

    Science.gov (United States)

    Takehara, Naofumi; Matsubara, Hiroaki

    2011-12-01

    Without heart transplantation, a large number of patients with failing hearts worldwide face poor outcomes. By means of cardiomyocyte regeneration, cardiac regeneration therapy is emerging with great promise as a means for restoring loss of cardiac function. However, the limited success of clinical trials using bone marrow-derived cells and myoblasts with heterogeneous constituents, transplanted at a wide range of cell doses, has led to disagreement on the efficacy of cell therapy. It is therefore essential to reevaluate the evidence for the efficacy of cell-based cardiac regeneration therapy, focusing on targets, materials, and methodologies. Meanwhile, the revolutionary innovation of cardiac regeneration therapy is sorely needed to help the millions of people who suffer heart failure from acquired loss of cardiomyocytes. Cardiac regeneration has been used only in limited species or as a developing process in the rodent heart; now, the possibility of cardiomyocyte turnover in the human heart is being revisited. In the pursuit of this concept, the use of cardiac stem/progenitor stem cells in the cardiac niche must be focused to usher in a second era of cardiac regeneration therapy for the severely injured heart. In addition, tissue engineering and cellular reprogramming will advance the next era of treatment that will enable current cell-based therapy to progress to "real" cardiac regeneration therapy. Although many barriers remain, the prevention of refractory heart failure through cardiac regeneration is now becoming a realistic possibility.

  3. The effect of aging on pacing strategies of cross-country skiers and the role of performance level.

    Science.gov (United States)

    Nikolaidis, Pantelis Theodoros; Villiger, Elias; Rosemann, Thomas; Knechtle, Beat

    2018-01-01

    The participation of master cross-country (XC) skiers in training and competition has increased during the last decades; however, little is known yet about whether these athletes differ from their younger counterparts in aspects of performance such as pacing. Therefore, the aim of the present study was to examine the combined effect of age and performance (race time) on pacing in cross-country (XC) skiing. We analyzed all finishers ( n  = 79,722) in 'Vasaloppet' from 2012 to 2017, the largest cross-country skiing race in the world, classified according to their race time into 10 groups: 3-4 h, 4-5 h, ..., 12-13 h. A trivial main effect of sex on total pace range was observed ( p  < 0.001, η 2  = 0.002), where women (44.1 ± 10.2%) had larger total pace range than men (40.9 ± 11.8%). A large main effect of performance group on total pace range was shown ( p  < 0.001, η 2  = 0.160), where the smallest total pace range was 21.8 ± 1.9% (3-4 h group) and the largest 50.1 ± 9.9% (10-11 h group). A trivial sex×performance group interaction on total pace range was found ( p  < 0.001, η 2  = 0.001) with the largest sex difference in pacing shown in 9-10 h group. A trivial and small main effect of age was found in women ( p  < 0.001, η 2  = 0.005) and men ( p  < 0.001, η 2  = 0.011), respectively, where the masters had smaller total pace range than their younger counterparts. A trivial age group×performance group interaction on total pace range was observed in both women ( p  < 0.001, η 2  = 0.008) and men ( p  < 0.001, η 2  = 0.006) with smaller differences among age groups in the faster performance groups. In summary, master XC skiers adopted a relatively even pacing independently from their race time and the differences in pacing from the younger XC skiers were more pronounced in the slower masters. These findings suggest that exercise attenuates the decline of performance in

  4. Pacing in congenital heart disease - A four-decade experience in a single tertiary centre.

    Science.gov (United States)

    Midha, Disha; Chen, Zhong; Jones, David G; Williams, Howell J; Lascelles, Karen; Jarman, Julian; Clague, Jonathan; Till, Janice; Dimopoulos, Konstatinos; Babu-Narayan, Sonya V; Markides, Vias; Gatzoulis, Michael A; Wong, Tom

    2017-08-15

    The increased risk of brady- and tachy-arrhythmias in the congenital heart disease (CHD) population means that cardiac rhythm management devices are often required at an early age and expose patients to device-related complications. The present study drew upon four decades of experience at a tertiary adult congenital heart disease ACHD center and aimed to investigate the indication for cardiac implantable electronic devices (CIEDs) and predictors of late device-related complication requiring re-intervention. A retrospective review of pacing records of ACHD patients over forty years was carried out. The primary outcome measure was device related complication requiring re-intervention. Between 1970 and 2009, 238 structural CHD patients who received CIEDs with follow-up data were identified (structural group). As a comparator group, 98 patients with congenital conduction disease or long QT syndrome with a structurally normal heart (electrical group) were included in the study. During a mean follow-up of 9.6±8.5years, 72 (21%) patients (44 structural group, 28 electrical group) required ≥1 re-intervention due to device related complications. Multivariate analysis showed that age at the time of device implant was an independent predictor of late device-related complications (HR 0.77, 95% CI 0.60-0.98, p=0.04). Sub-analysis of the structural group showed that ACHD complexity (Bethesda guideline) was the only predictor late device-related complication in the structural group (HR 2.96, 95% CI: 1.67-5.26, p<0.01). Increasing age at device implant was inversely associated with late device-related complications. ACHD patients with complex anatomy are at increased risk of device-related complications at mid and long-term follow-up. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Activation of the Prefrontal Cortex While Performing a Task at Preferred Slow Pace and Metronome Slow Pace: A Functional Near-Infrared Spectroscopy Study

    Directory of Open Access Journals (Sweden)

    Kaori Shimoda

    2014-01-01

    Full Text Available Individuals have a preferred pace at which they perform voluntary repetitive movements. Previous studies have reported that greater activation of the prefrontal cortex was observed during self-initiated movements than during externally triggered movements. The purpose of the present study is to compare the activation of the prefrontal cortex induced when the subjects performed a peg-board task at their preferred slow pace (PSP, the self-initiated condition with that induced when they performed the same task at metronome slow pace (MSP, the externally triggered condition using functional near-infrared spectroscopy. Healthy subjects performed the task while sitting in a chair. By assessing the activated channels individually, we confirmed that all of the prefrontal regions of interest were activated by both tasks. In the second-level analyses, we found that the activation detected in the frontopolar cortex (FPPFC; Brodmann area 10 was higher during the PSP task than during the MSP task. The FPPFC is known to be at the top of prefrontal hierarchy, and specifically involved in evaluating self-generated information. In addition, the FPPFC plays a role in coordinating lateral prefrontal cortex. In the present study, the subjects evaluated and managed the internally generated PSP by coordinating the activity of other lower level prefrontal regions.

  6. Activation of the prefrontal cortex while performing a task at preferred slow pace and metronome slow pace: a functional near-infrared spectroscopy study.

    Science.gov (United States)

    Shimoda, Kaori; Moriguchi, Yoshiya; Tsuchiya, Kenji; Katsuyama, Shiori; Tozato, Fusae

    2014-01-01

    Individuals have a preferred pace at which they perform voluntary repetitive movements. Previous studies have reported that greater activation of the prefrontal cortex was observed during self-initiated movements than during externally triggered movements. The purpose of the present study is to compare the activation of the prefrontal cortex induced when the subjects performed a peg-board task at their preferred slow pace (PSP, the self-initiated condition) with that induced when they performed the same task at metronome slow pace (MSP, the externally triggered condition) using functional near-infrared spectroscopy. Healthy subjects performed the task while sitting in a chair. By assessing the activated channels individually, we confirmed that all of the prefrontal regions of interest were activated by both tasks. In the second-level analyses, we found that the activation detected in the frontopolar cortex (FPPFC; Brodmann area 10) was higher during the PSP task than during the MSP task. The FPPFC is known to be at the top of prefrontal hierarchy, and specifically involved in evaluating self-generated information. In addition, the FPPFC plays a role in coordinating lateral prefrontal cortex. In the present study, the subjects evaluated and managed the internally generated PSP by coordinating the activity of other lower level prefrontal regions.

  7. FLOATING ATRIAL SENSING OF THE VDD PACING SYSTEM AND ITS STABILITY

    Directory of Open Access Journals (Sweden)

    Tomislav Kostić

    2014-03-01

    Full Text Available mulate two heart chambers (usually the right atrium and right ventricle were de-signed. Those pacemakers were able to detect signals from the same heart chamber, and each of its functions (detection of intrinsing and application of artificial pacemaker signal was performed as previously programmed. Essential hemodynamic improvement of this type of stimulation was the achievement of AV synchronization allowing that optimized function of the atria and ventricles mimics their natural functioning - timely contraction of the atria in relation to the AV valves and the ventricular outflow tracts. This study included 130 patients who had VDD pacemaker implanted at the Department of Cardiology, Clinical Center Niš, during 2009-2013. At the time of implantation, atrial sensing was 2.1±1.2 mV. Patients had follow up visits at one month, six months and one year after pacemaker implantation. After one year, the floating sensing in the atrium was 1.6±0.7 mV which was lower but not clinically significant. Bearing in mind the aforementioned, VVD pacing systems may be considered as the first line therapy in patients with AV block and normal SA node function, particularly in elderly patients and in patients with unsuitable anatomical structures of musculoskeletal and venous systems of the upper thoracic part, in cases of which it is sometimes difficult to place two DDDR electrode systems.

  8. Total Artificial Heart Implantation as a Bridge to Heart Transplantation in an Active Duty Service Member With Amyloid Cardiomyopathy.

    Science.gov (United States)

    Scully, Michael S; Wessman, Dylan E; McKee, James M; Francisco, Gregory M; Nayak, Keshav R; Kobashigawa, Jon A

    2017-03-01

    Cardiac involvement by light-chain (AL) amyloid occurs in up to 50% of patients with primary AL amyloidosis. The prognosis of amyloid heart disease is poor with 1-year survival rates of 35 to 40%. Historically, heart transplantation was considered controversial for patients with AL amyloid cardiomyopathy (CM) given the systemic nature of the disease and poor survival. We present a case report of an active duty service member diagnosed with advanced cardiac amyloid who underwent total artificial heart transplant as a bridge to heart transplant and eventual autologous stem cell transplant. A 47-year-old active duty male initially evaluated for atypical chest pain was found to have severe concentric left ventricular hypertrophy on echocardiogram but normal voltage on electrocardiogram. Cardiac magnetic resonance imaging, laboratory studies, and bone marrow biopsy established the diagnosis of cardiac amyloidosis. At the time of diagnosis, the patient's prognosis was very poor with a median survival of 5 months on the basis of the Mayo Clinic revised prognostic staging system for amyloidosis. The patient developed rapidly progressive left ventricular dysfunction and heart failure leading to cardiac arrest. The patient received a total artificial heart as a bridge to orthotopic heart and kidney transplantation and eventual stem cell transplant. He continues to be in remission and has a fair functional capacity without restriction in activities of daily living or moderate exercise. Amyloid CM is a rare and devastating disease. The natural course of the disease has made heart transplant in these patients controversial. Modern advancements in chemotherapies and advanced heart failure treatments have improved outcomes for select patients with AL amyloid CM undergoing heart transplantation. There is ongoing research seeking improvement in treatment options and outcomes for patients with this deadly disease. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  9. A Report of Brugada Syndrome Presenting with Cardiac Arrest Triggered by Verapamil Intoxication

    Directory of Open Access Journals (Sweden)

    Kahraman Yakut

    2017-12-01

    Full Text Available Background: Brugada syndrome is a disease characterized by a specific electrocardiographic pattern and an increased risk of sudden cardiac death. We present this case with the updated literature to emphasise the need to consider the diagnosis of Brugada syndrome in patients admitted to the emergency ward with sudden cardiac arrest. Case Report: A 16-year-old female patient was admitted to the emergency ward with complaints of weakness and abdominal pain, and she had four cardiac arrests during her evaluation period. She was referred to our clinic for permanent pacemaker implantation. She was on a temporary pace maker after having had C-reactive protein. Her physical exam was normal except for bilaterally decreased lung sounds. Lung x-ray and computed tomography, which were performed by another institution, revealed minimal pleural effusion and nothing else of significance. Blood and peritoneal fluid samples were sterile. Echocardiographic exam and cardiac enzymes were also in the normal ranges. Electrocardiographic showed incomplete right branch block in leads V1 and V2. An ajmaline test revealed specific electrocardiographic findings of the type I Brugada pattern. We proposed implanting an implantable cardioverter defibrillator to the patient as there were positive findings on the ajmaline test as well as a history of sudden cardiac arrest. After this treatment proposal, the patient’s family admitted that she had taken a high dose of verapamil and thus, the encountered bradycardia was associated with verapamil overuse. The ajmaline test was repeated as it was contemplated that the previous positive ajmaline test had been associated with verapamil overuse. Implantable cardioverter defibrillator implantation was proposed again as there was a history of sudden cardiac arrest; however, the family did not consent to implantable cardioverter defibrillator, and the patient was discharged and followed up. Conclusion: Brugada syndrome should be

  10. Sedation and Anesthesia in Pediatric and Congenital Cardiac Catheterization: A Prospective Multicenter Experience.

    Science.gov (United States)

    Lin, C Huie; Desai, Sanyukta; Nicolas, Ramzi; Gauvreau, Kimberlee; Foerster, Susan; Sharma, Anshuman; Armsby, Laurie; Marshall, Audrey C; Odegard, Kirsten; DiNardo, James; Vincent, Julie; El-Said, Howaida; Spaeth, James; Goldstein, Bryan; Holzer, Ralf; Kreutzer, Jackie; Balzer, David; Bergersen, Lisa

    2015-10-01

    Sedation/anesthesia is critical to cardiac catheterization in the pediatric/congenital heart patient. We sought to identify current sedation/anesthesia practices, the serious adverse event rate related to airway, sedation, or anesthesia, and the rate of intra-procedural conversion from procedural sedation to the use of assisted ventilation or an artificial airway. Data from 13,611 patients who underwent catheterization at eight institutions were prospectively collected from 2007 to 2010. Ninety-four (0.69 %) serious sedation/airway-related adverse events occurred; events were more likely to occur in smaller patients (anesthesia, LMA, or tracheostomy, whereas 4232 (31 %) were managed with procedural sedation without an artificial airway, of which 75 (1.77 %) patients were converted to assisted ventilation/general anesthesia. Young age (risk procedure (category 4, OR 10.1, 95 % CI 6.5-15.6, p pediatric/congenital patients was associated with a low rate of serious sedation/airway-related adverse events. Smaller patients with non-cardiac comorbidities or low mixed venous oxygen saturation may be at higher risk. Patients under 1 year of age, undergoing high-risk procedures, or requiring continuous pressor/inotrope support may be at higher risk of requiring conversion from procedural sedation to assisted ventilation/general anesthesia.

  11. What Pacemakers Can Teach Us about the Ethics of Maintaining Artificial Organs.

    Science.gov (United States)

    Hutchison, Katrina; Sparrow, Robert

    2016-11-01

    One day soon it may be possible to replace a failing heart, liver, or kidney with a long-lasting mechanical replacement or perhaps even with a 3-D printed version based on the patient's own tissue. Such artificial organs could make transplant waiting lists and immunosuppression a thing of the past. Supposing that this happens, what will the ongoing care of people with these implants involve? In particular, how will the need to maintain the functioning of artificial organs over an extended period affect patients and their doctors and the responsibilities of those who manufacture such devices? Drawing on lessons from the history of the cardiac pacemaker, this article offers an initial survey of the ethical issues posed by the need to maintain and service artificial organs. We briefly outline the nature and history of cardiac pacemakers, with a particular focus on the need for technical support, maintenance, and replacement of these devices. Drawing on the existing medical literature and on our conversations and correspondence with cardiologists, regulators, and manufacturers, we describe five sources of ethical issues associated with pacemaker maintenance: the location of the devices inside the human body, such that maintenance generates surgical risks; the complexity of the devices, which increases the risk of harms to patients as well as introducing potential injustices in access to treatment; the role of software-particularly software that can be remotely accessed-in the functioning of the devices, which generates privacy and security issues; the impact of continual development and improvement of the device; and the influence of commercial interests in the context of a medical device market in which there are several competing products. Finally, we offer some initial suggestions as to how these questions should be answered. © 2016 The Hastings Center.

  12. Atrial antitachycardia pacing and atrial remodeling: A substudy of the international, randomized MINERVA trial.

    Science.gov (United States)

    Boriani, Giuseppe; Tukkie, Raymond; Biffi, Mauro; Mont, Lluis; Ricci, Renato; Pürerfellner, Helmut; Botto, Giovanni Luca; Manolis, Antonis S; Landolina, Maurizio; Gulizia, Michele; Hudnall, J Harrison; Mangoni, Lorenza; Grammatico, Andrea; Padeletti, Luigi

    2017-10-01

    Atrial tachycardia (AT) and atrial fibrillation (AF) are common in pacemaker patients and are associated with bad prognoses. The purpose of this study was to evaluate atrial antitachycardia pacing impact on AT/AF-induced atrial remodeling, measured by early recurrence of AT/AF (ERAF) and by change in left atrial diameter (LAD), and to evaluate the impact of AT/AF duration on ERAF incidence. Pacemaker patients were randomized to dual-chamber pacing (Control DDDR: 385 patients), managed ventricular pacing (MVP: 398 patients), or atrial antitachycardia pacing plus MVP (DDDRP+MVP: 383 patients). LAD change, estimated by echocardiography, was considered significant if the relative difference between baseline and 24-month measurements was >10%. At median follow-up of 34 months, ERAF incidence was significantly lower in the DDDRP+MVP arm for all AT/AF durations, in particular, ERAF followed AT/AF longer than 3 hours in 53% cases in Control DDDR, in 51% cases in MVP, and in 39% cases in DDDRP+MVP (P MVP, and 70% in DDDRP+MVP (P MVP, DDDRP+MVP reduces ERAF and favors LAD reduction, suggesting that atrial antitachycardia pacing may reverse electrical and mechanical remodeling. Copyright © 2017 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  13. Artificial Consciousness or Artificial Intelligence

    OpenAIRE

    Spanache Florin

    2017-01-01

    Artificial intelligence is a tool designed by people for the gratification of their own creative ego, so we can not confuse conscience with intelligence and not even intelligence in its human representation with conscience. They are all different concepts and they have different uses. Philosophically, there are differences between autonomous people and automatic artificial intelligence. This is the difference between intelligence and artificial intelligence, autonomous versus a...

  14. Tissue-Mimicking Geometrical Constraints Stimulate Tissue-Like Constitution and Activity of Mouse Neonatal and Human-Induced Pluripotent Stem Cell-Derived Cardiac Myocytes

    Directory of Open Access Journals (Sweden)

    Götz Pilarczyk

    2016-01-01

    Full Text Available The present work addresses the question of to what extent a geometrical support acts as a physiological determining template in the setup of artificial cardiac tissue. Surface patterns with alternating concave to convex transitions of cell size dimensions were used to organize and orientate human-induced pluripotent stem cell (hIPSC-derived cardiac myocytes and mouse neonatal cardiac myocytes. The shape of the cells, as well as the organization of the contractile apparatus recapitulates the anisotropic line pattern geometry being derived from tissue geometry motives. The intracellular organization of the contractile apparatus and the cell coupling via gap junctions of cell assemblies growing in a random or organized pattern were examined. Cell spatial and temporal coordinated excitation and contraction has been compared on plain and patterned substrates. While the α-actinin cytoskeletal organization is comparable to terminally-developed native ventricular tissue, connexin-43 expression does not recapitulate gap junction distribution of heart muscle tissue. However, coordinated contractions could be observed. The results of tissue-like cell ensemble organization open new insights into geometry-dependent cell organization, the cultivation of artificial heart tissue from stem cells and the anisotropy-dependent activity of therapeutic compounds.

  15. Social Interaction in Self-paced Distance Education

    Directory of Open Access Journals (Sweden)

    Terry Anderson

    2015-02-01

    Full Text Available In this paper we present a case study of a self-paced university course that was originally designed to support independent, self-paced study at distance. We developed a social media intervention, in design-based research terms, that allows these independent students to contribute archived content to enhance the course, to engage in discussions with other students and to share as little or as much personal information with each other as they wished. We describe the learning design for the intervention and present survey data of student and tutor perception of value and content analysis of the archived contributions. The results indicate that the intervention was positively received by tutors and by the majority (but not all students and that the archive created by the students’ contributions was adding value to the course. We conclude that the intervention was a modest, yet manageable example of a learning enhancement to a traditional cognitive-behavioral, course that has positive impact and potential with little negative impact on workload.

  16. Pacing the US magnetic fusion program

    International Nuclear Information System (INIS)

    1989-01-01

    This study addresses the priority and pace of the nation's magnetic fusion research and development program in the context of long-term national energy policy. In particular, the committee interpreted its task as follows: To review the implications of long-term national energy policy for current research and development in magnetic fusion; to identify factors that should enter the further development of such policy to reduce risks associated with the future electricity supply system; to propose criteria applicable to research and develop in electric generation in reaching long-term energy policy goals; to apply these criteria to magnetic fusion and alternative electric generation technologies in order to develop recommendations on the priority pace of the magnetic fusion program; and to present its results in a final report. The most important goals of the US Department of Energy's current Magnetic Fusion Energy Program Plan are to demonstrate the scientific and engineering feasibility of fusion, Demonstrating engineering feasibility will require the design, construction, and operation of an engineering test reactor, which the plan envisions financing through a combination of domestic and international funding. The committee believes that current domestic program funding levels are inadequate to meet even the near-term objectives of the plan

  17. Stimulation of ganglionated plexus attenuates cardiac neural remodeling and heart failure progression in a canine model of acute heart failure post-myocardial infarction.

    Science.gov (United States)

    Luo, Da; Hu, Huihui; Qin, Zhiliang; Liu, Shan; Yu, Xiaomei; Ma, Ruisong; He, Wenbo; Xie, Jing; Lu, Zhibing; He, Bo; Jiang, Hong

    2017-12-01

    Heart failure (HF) is associated with autonomic dysfunction. Vagus nerve stimulation has been shown to improve cardiac function both in HF patients and animal models of HF. The purpose of this present study is to investigate the effects of ganglionated plexus stimulation (GPS) on HF progression and autonomic remodeling in a canine model of acute HF post-myocardial infarction. Eighteen adult mongrel male dogs were randomized into the control (n=8) and GPS (n=10) groups. All dogs underwent left anterior descending artery ligation followed by 6-hour high-rate (180-220bpm) ventricular pacing to induce acute HF. Transthoracic 2-dimensional echocardiography was performed at different time points. The plasma levels of norepinephrine, B-type natriuretic peptide (BNP) and Ang-II were measured using ELISA kits. C-fos and nerve growth factor (NGF) proteins expressed in the left stellate ganglion as well as GAP43 and TH proteins expressed in the peri-infarct zone were measured using western blot. After 6h of GPS, the left ventricular end-diastolic volume, end-systolic volume and ejection fraction showed no significant differences between the 2 groups, but the interventricular septal thickness at end-systole in the GPS group was significantly higher than that in the control group. The plasma levels of norepinephrine, BNP, Ang-II were increased 1h after myocardial infarction while the increase was attenuated by GPS. The expression of c-fos and NGF proteins in the left stellate ganglion as well as GAP43 and TH proteins in cardiac peri-infarct zone in GPS group were significantly lower than that in control group. GPS inhibits cardiac sympathetic remodeling and attenuates HF progression in canines with acute HF induced by myocardial infarction and ventricular pacing. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Endotracheal Use of Perfluorane in Patients with Acute Respiratory Distress Syndrome Under Artificial Ventilation

    Directory of Open Access Journals (Sweden)

    V. V. Moroz

    2005-01-01

    Full Text Available The paper presents the results of a comparative study of different routes of intrapulmonary administration of perfluorane under artificial ventilation in patients with acute respiratory distress syndrome of various genesis. It shows the advantages and disadvantages of these routes, their impact on gas exchange, pulmonary biomechanical properties, cardiac hemodynamics, the transport and uptake of oxygen, the duration of respiratory support, and the length of stay in an intensive care unit.

  19. A fast-start pacing strategy speeds pulmonary oxygen uptake kinetics and improves supramaximal running performance.

    Directory of Open Access Journals (Sweden)

    Tiago Turnes

    Full Text Available The focus of the present study was to investigate the effects of a fast-start pacing strategy on running performance and pulmonary oxygen uptake (VO2 kinetics at the upper boundary of the severe-intensity domain. Eleven active male participants (28±10 years, 70±5 kg, 176±6 cm, 57±4 mL/kg/min visited the laboratory for a series of tests that were performed until exhaustion: 1 an incremental test; 2 three laboratory test sessions performed at 95, 100 and 110% of the maximal aerobic speed; 3 two to four constant speed tests for the determination of the highest constant speed (HS that still allowed achieving maximal oxygen uptake; and 4 an exercise based on the HS using a higher initial speed followed by a subsequent decrease. To predict equalized performance values for the constant pace, the relationship between time and distance/speed through log-log modelling was used. When a fast-start was utilized, subjects were able to cover a greater distance in a performance of similar duration in comparison with a constant-pace performance (constant pace: 670 m±22%; fast-start: 683 m±22%; P = 0.029; subjects also demonstrated a higher exercise tolerance at a similar average speed when compared with constant-pace performance (constant pace: 114 s±30%; fast-start: 125 s±26%; P = 0.037. Moreover, the mean VO2 response time was reduced after a fast start (constant pace: 22.2 s±28%; fast-start: 19.3 s±29%; P = 0.025. In conclusion, middle-distance running performances with a duration of 2-3 min are improved and VO2 response time is faster when a fast-start is adopted.

  20. Voltage and pace-capture mapping of linear ablation lesions overestimates chronic ablation gap size.

    Science.gov (United States)

    O'Neill, Louisa; Harrison, James; Chubb, Henry; Whitaker, John; Mukherjee, Rahul K; Bloch, Lars Ølgaard; Andersen, Niels Peter; Dam, Høgni; Jensen, Henrik K; Niederer, Steven; Wright, Matthew; O'Neill, Mark; Williams, Steven E

    2018-04-26

    Conducting gaps in lesion sets are a major reason for failure of ablation procedures. Voltage mapping and pace-capture have been proposed for intra-procedural identification of gaps. We aimed to compare gap size measured acutely and chronically post-ablation to macroscopic gap size in a porcine model. Intercaval linear ablation was performed in eight Göttingen minipigs with a deliberate gap of ∼5 mm left in the ablation line. Gap size was measured by interpolating ablation contact force values between ablation tags and thresholding at a low force cut-off of 5 g. Bipolar voltage mapping and pace-capture mapping along the length of the line were performed immediately, and at 2 months, post-ablation. Animals were euthanized and gap sizes were measured macroscopically. Voltage thresholds to define scar were determined by receiver operating characteristic analysis as voltage, pace-capture, and ablation contact force maps. All modalities overestimated chronic gap size, by 1.4 ± 2.0 mm (ablation contact force map), 5.1 ± 3.4 mm (pace-capture), and 9.5 ± 3.8 mm (voltage mapping). Error on ablation contact force map gap measurements were significantly less than for voltage mapping (P = 0.003, Tukey's multiple comparisons test). Chronically, voltage mapping and pace-capture mapping overestimated macroscopic gap size by 11.9 ± 3.7 and 9.8 ± 3.5 mm, respectively. Bipolar voltage and pace-capture mapping overestimate the size of chronic gap formation in linear ablation lesions. The most accurate estimation of chronic gap size was achieved by analysis of catheter-myocardium contact force during ablation.

  1. The Myocardial Ischemia Evaluated by Real-Time Contrast Echocardiography May Predict the Response to Cardiac Resynchronization Therapy: A Large Animal Study

    Science.gov (United States)

    Chen, Yongle; Cheng, Leilei; Yao, Haohua; Chen, Haiyan; Wang, Yongshi; Zhao, Weipeng; Pan, Cuizhen; Shu, Xianhong

    2014-01-01

    Evidence-based criteria for applying cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy are still scarce. The aim of the present study was to evaluate the predictive value of real-time myocardial contrast echocardiography (RT-MCE) in a preclinical canine model of ischemic cardiomyopathy who received CRT. Ischemic cardiomyopathy was produced by ligating the first diagonal branch in 20 beagles. Dogs were subsequently divided into two groups that were either treated with bi-ventricular pacing (CRT group) or left untreated (control group). RT-MCE was performed at baseline, before CRT, and 4 weeks after CRT. Two-dimensional speckle tracking imaging was used to evaluate the standard deviation of circumferential (Cir12SD), radial (R12SD), and longitudinal (L12SD) strains of left ventricular segments at basal as well as middle levels. Four weeks later, the Cir12SD, R12SD, and myocardial blood flow (MBF) of the treated group were significantly improved compared to their non-CRT counterparts. Furthermore, MBF values measured before CRT were significantly higher in responders than in non-responders to bi-ventricular pacing. Meanwhile, no significant differences were observed between the responder and non-responder groups in terms of Cir12SD, R12SD, and L12SD. A high degree of correlation was found between MBF values before CRT and LVEF after CRT. When MBF value>24.9 dB/s was defined as a cut-off point before CRT, the sensitivity and specificity of RT-MCE in predicting the response to CRT were 83.3% and 100%, respectively. Besides, MBF values increased significantly in the CRT group compared with the control group after 4 weeks of pacing (49.8±15.5 dB/s vs. 28.5±4.6 dB/s, p<0.05). Therefore, we considered that myocardial perfusion may be superior to standard metrics of LV synchrony in selecting appropriate candidates for CRT. In addition, CRT can improve myocardial perfusion in addition to cardiac synchrony, especially in the setting of ischemic

  2. Halogenated anaesthetics and cardiac protection in cardiac and non-cardiac anaesthesia

    Directory of Open Access Journals (Sweden)

    Landoni Giovanni

    2009-01-01

    Full Text Available Volatile anaesthetic agents have direct protective properties against ischemic myocardial damage. The implementation of these properties during clinical anaesthesia can provide an additional tool in the treatment or prevention, or both, of ischemic cardiac dysfunction in the perioperative period. A recent meta-analysis showed that desflurane and sevoflurane reduce postoperative mortality and incidence of myocardial infarction following cardiac surgery, with significant advantages in terms of postoperative cardiac troponin release, need for inotrope support, time on mechanical ventilation, intensive care unit and overall hospital stay. Multicentre, randomised clinical trials had previously demonstrated that the use of desflurane can reduce the postoperative release of cardiac troponin I, the need for inotropic support, and the number of patients requiring prolonged hospitalisation following coronary artery bypass graft surgery either with and without cardiopulmonary bypass. The American College of Cardiology/American Heart Association Guidelines recommend volatile anaesthetic agents during non-cardiac surgery for the maintenance of general anaesthesia in patients at risk for myocardial infarction. Nonetheless, e vidence in non-coronary surgical settings is contradictory and will be reviewed in this paper together with the mechanisms of cardiac protection by volatile agents.

  3. Urbanization Is Associated with Divergence in Pace-of-Life in Great Tits

    Directory of Open Access Journals (Sweden)

    Anne Charmantier

    2017-05-01

    Full Text Available As an extension of the classic life history theory, the recently highlighted pace-of-life syndrome hypothesis predicts the coevolution of behavioral, physiological and life-history traits. For instance, bolder and shyer individuals do not only differ in personality profiles, but also in neuro-endocrinology and breeding patterns. While theory predicts that bolder (i.e., proactive, more aggressive individuals should colonize more rapidly urbanized habitats than shyer (i.e., reactive, less aggressive individuals, it is also predicted that across generations, adaptive selection processes could favor shyer individuals that are more sensitive to novel environmental cues. Here we compared two personality traits (handling aggression, exploration score in a novel environment, one physiological trait related to stress response (breath rate and four breeding traits (lay date, clutch size, hatching success and fledging success in a rural and an urban study population of Mediterranean great tits Parus major. Mixed models revealed strong phenotypic divergence between forest and city in most traits explored, in particular in personality, whereby urban great tits were more reactive to stress and faster explorers compared to rural birds (yet not more aggressive. Urban birds also laid smaller broods earlier in spring compared to their rural conspecifics, and city broods resulted in lower hatching success yet interestingly fledging success was similar. Nest-box centered measures of anthropogenic (artificial light, pedestrians, and cars perturbation and resource abundance allowed us to go beyond the classical forest/city comparison by exploring the phenotypic variation across an urbanization gradient. This revealed that high urbanization in nest-box surroundings was associated overall with earlier breeding and smaller clutches, but also with faster breath rate, although these trends showed strong annual variation. Ongoing rapid urbanization and non-random gene flow

  4. [Influence of pacing site on myocardial transmural dispersion of repolarization in intact normal and dilated cardiomyopathy dogs].

    Science.gov (United States)

    Bai, Rong; Pu, Jun; Liu, Nian; Lu, Jia-Gao; Zhou, Qiang; Ruan, Yan-Fei; Niu, Hui-Yan; Wang, Lin

    2003-12-25

    In order to verify the hypothesis that left ventricular epicardial (LV-Epi) pacing and biventricular (BiV) pacing unavoidably influence the myocardial electrophysiological characters and may result in high risk of malignant ventricular arrhythmia, we calculated, in both normal mongrel dogs and dog models with rapid-right-ventricular-pacing induced dilated cardiomyopathy congestive heart failure (DCM-CHF), the monophasic action potential duration (MAPD) and the transmural dispersion of repolarization (TDR) in intracardiac electrogram together with the QT interval and T(peak)-T(end) (T(p(-T(e)) interval in surface electrocardiogram (ECG) during LV-Epi and BiV pacing, compared with those during right ventricular endocardial (RV-Endo) pacing. To prepare the DCM-CHF dog model, rapid right ventricular pacing (250 bpm) was performed for 23.6+/-2.57 days to the dog. All the normal and DCM-CHF dogs were given radio frequency catheter ablation (RFCA) to His bundle with the guide of X-ray fluoroscopy. After the RFCA procedures, the animals were under the situation of complete atrioventricular block so that the canine heart rates could be voluntarily controlled in the following experiments. After a thoracotomy, ECG and monophasic action potentials (MAP) of subendocardial, subepicardial and mid-layer myocardium were recorded synchronously in 8 normal and 5 DCM-CHF dogs during pacing from endocardium of RV apex (RV-Endo), epicardium of LV anterior wall (LV-Epi) and simultaneously both of the above (biventricular, BiV), the later was similar to the ventricular resynchronization therapy to congestive heart failure patients in clinic. The Tp-Te) meant the interval from the peak to the end of T wave, which was a representative index of TDR in surface ECG. The TDR was defined as the difference between the longest and the shortest MAPD of subendocardial, subepicardial and mid-layer myocardium. Our results showed that in normal dogs, pacing participating of LV (LV-Epi, BiV) prolonged

  5. Vocal cord collapse during phrenic nerve-paced respiration in congenital central hypoventilation syndrome.

    Science.gov (United States)

    Domanski, Mark C; Preciado, Diego A

    2012-01-01

    Phrenic nerve pacing can be used to treat congenital central hypoventilation syndrome (CCHS). We report how the lack of normal vocal cord tone during phrenic paced respiration can result in passive vocal cord collapse and produce obstructive symptoms. We describe a case of passive vocal cord collapse during phrenic nerve paced respiration in a patient with CCHS. As far as we know, this is the first report of this etiology of airway obstruction. The patient, a 7-year-old with CCHS and normal waking vocal cord movement, continued to require nightly continuous positive airway pressure (CPAP) despite successful utilization of phrenic nerve pacers. On direct laryngoscopy, the patient's larynx was observed while the diaphragmatic pacers were sequentially engaged. No abnormal vocal cord stimulation was witnessed during engaging of either phrenic nerve stimulator. However, the lack of normal inspiratory vocal cord abduction during phrenic nerve-paced respiration resulted in vocal cord collapse and partial obstruction due to passive adduction of the vocal cords through the Bernoulli effect. Bilateral phrenic nerve stimulation resulted in more vocal cord collapse than unilateral stimulation. The lack of vocal cord abduction on inspiration presents a limit to phrenic nerve pacers.

  6. Chest radiographic findings and complications of the temporary implantation of the Jarvik-7 artificial heart while awaiting orthotopic heart transplantation: Experience with five cases

    International Nuclear Information System (INIS)

    Sadler, L.R.; Fuhrman, C.R.; Hardesty, R.A.; Griffith, B.P.

    1986-01-01

    The Jarvik-7 artificial heart was originally introduced as a therapeutic alternative to cardiac transplantation in patients with endstage refractory cardiac disease. Its use has been expanded to those patients awaiting cardiac transplantation in whom death is impending and for whom a suitable donor match is unavailable. At Presbyterian-University Hospital of Pittsburgh five patients have had Jarvik-7 hearts implanted as a temporary measure while awaiting compatible donors for cardiac transplantation. The authors believe this is the largest patient group to undergo this procedure at a single institution. They present a brief description of the Jarvik-7 heart, the clinical factors affecting patient selection, and the radiographic appearance of a normally functioning Jarvik-7 heart, and review the chest radiographic complications seen in the patient group, along with eventual patient outcome

  7. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    Science.gov (United States)

    Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard

    2017-10-01

    Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Natural - synthetic - artificial!

    DEFF Research Database (Denmark)

    Nielsen, Peter E

    2010-01-01

    The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life.......The terms "natural," "synthetic" and "artificial" are discussed in relation to synthetic and artificial chromosomes and genomes, synthetic and artificial cells and artificial life....

  9. Towards PACE Atmospheric Correction, Aerosol and Cloud Products: Making Use of Expanded Spectral, Angular and Polarimetric Information.

    Science.gov (United States)

    Remer, L. A.; Boss, E.; Ahmad, Z.; Cairns, B.; Chowdhary, J.; Coddington, O.; Davis, A. B.; Dierssen, H. M.; Diner, D. J.; Franz, B. A.; Frouin, R.; Gao, B. C.; Garay, M. J.; Heidinger, A.; Ibrahim, A.; Kalashnikova, O. V.; Knobelspiesse, K. D.; Levy, R. C.; Omar, A. H.; Meyer, K.; Platnick, S. E.; Seidel, F. C.; van Diedenhoven, B.; Werdell, J.; Xu, F.; Zhai, P.; Zhang, Z.

    2017-12-01

    NASA's Science Team for the Plankton, Aerosol, Clouds, ocean Ecosystem (PACE) mission is concluding three years of study exploring the science potential of expanded spectral, angular and polarization capability for space-based retrievals of water leaving radiance, aerosols and clouds. The work anticipates future development of retrievals to be applied to the PACE Ocean Color Instrument (OCI) and/or possibly a PACE Multi-Angle Polarimeter (MAP). In this presentation we will report on the Science Team's accomplishments associated with the atmosphere (significant efforts are also directed by the ST towards the ocean). Included in the presentation will be sensitivity studies that explore new OCI capabilities for aerosol and cloud layer height, aerosol absorption characterization, cloud property retrievals, and how we intend to move from heritage atmospheric correction algorithms to make use of and adjust to OCI's hyperspectral and UV wavelengths. We will then address how capabilities will improve with the PACE MAP, how these capabilities from both OCI and MAP correspond to specific societal benefits from the PACE mission, and what is still needed to close the gaps in our understanding before the PACE mission can realize its full potential.

  10. Towards optical spectroscopic anatomical mapping (OSAM) for lesion validation in cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.

    2017-02-01

    Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.

  11. ECG-gated myocardial tomo-scintigraphy by rotating bilateral collimator. Clinical application and artificial defect

    Energy Technology Data Exchange (ETDEWEB)

    Komatani, Akio; Takahashi, Kazuei; Takanashi, Toshiyasu; Yamaguchi, Koichi [Yamagata Univ. (Japan)

    1985-01-01

    Tomo-scintigraphy of /sup 201/Tl-myocardium by rotating bilateral collimator was performed in synchronization with cardiac cycle. Ten frames per R-R interval were acquired with ECG pulse signal during 16 min and tomographic reconstruction of end-diastolic and end-systolic image was done. This method was very useful to estimate not only three dimensional distribution of Tl-201, but also wall motion and change of wall thickness during cardiac cycle. However, through its clinical application, artificial defect was frequently noticed at inferior-apical portion of the myocardium. In order to elucidate the cause of the artifact, influence of tilted projection and cardiac motion due to respiratory was also investigated. During inspiratory phase of patients in rest, increment of volume up to 40% and 15 mm of caudal deviation of the left ventricle were observed. Furthermore, periodic motion of the diaphragm interrupted emission of gamma ray from the myocardium. It is proved that main cause of the artifact was not tilting projection, but these influence of respiratory motion.

  12. Morphological characteristic of surgically removed cardiac myxomas: 25-YEAR EXPERIENCE IN V.I. SHUMAKOV FEDERAL RESEARCH CENTER OF TRANSPLANTOLOGY AND ARTIFICIAL ORGANS

    Directory of Open Access Journals (Sweden)

    I. M. Iljinsky

    2017-01-01

    Full Text Available Analysis of intracardiac space-occupying lesions, surgically removed at V.I. Shumakov Federal Research Center of Transplantology and Artificial Organs over 25 years (in the period from 1992 until 2016 was carried out. During that period 134 patients underwent surgery. Preoperative clinical diagnosis before surgery was heart myxoma. From 134 patients, only in 115 (85.8% patients the removed intracardiac lesions were myxomas: left atrium – 103 (89.7% patients, right atrium – 10 (8.7%, right ventricle – 2 (1.8% and mitral valve – 1 (0.8% patient. 9 patients had thrombi in the heart, 10 patients had not myxomas, but other benign and malignant heart tumors. This article presents macroscopic, histolological and ultrastructural characteristic of cardiac myxomas. Recurrence of the left atrium myxoma occurred in 2 patients. They were re-operated in four and six years after the first removal of myxoma. 2 patients died during hospital period. One patient with atherosclerosis of the coronary arteries as a concurrent disease died of embolization of the stent coronary artery with myxoma particles with the development of acute heart failure. Death of the 2nd patient was not directly related to the surgery, and was due to the acute heart failure as well in connection with the presence of concurrent disease, coronary heart disease.

  13. Lithium toxicity precipitated by thyrotoxicosis due to silent thyroiditis: cardiac arrest, quadriplegia, and coma.

    Science.gov (United States)

    Sato, Yoshinori; Taki, Katsumi; Honda, Yuki; Takahashi, Shoichiro; Yoshimura, Ashio

    2013-06-01

    Lithium is widely used to treat bipolar disorders. Lithium toxicity is generally caused by inappropriately high doses of lithium or impaired lithium excretion. Most lithium is eliminated via the kidneys and, since thyroid hormone increases tubular reabsorption of lithium, thyrotoxicosis could contribute to the development of lithium toxicity. We report a case of severe lithium toxicity that was apparently precipitated by the onset of thyrotoxicosis resulting from silent thyroiditis and dehydration. The patient was a 64-year-old woman who was admitted for muscle weakness in the lower extremities, diarrhea, and palpitations. She had bipolar disorder and was being treated with lithium carbonate, which she discontinued one week before admission. Her circulating lithium levels had been monitored yearly. Early in her admission she was dehydrated and had febrile episodes, paroxysmal atrial fibrillation, and muscle weakness. Initially, fluid therapy was started, but she lost consciousness and had a cardiac arrest for 2 minutes due to prolonged sinus arrest. Chest compression and manual artificial ventilation were performed, and body surface pacing was started. Serum lithium was markedly elevated to 3.81 mEq/L (therapeutic range, 0.4-1.0 mEq/L), and thyroid hormone levels were increased (free triiodothyronine, 8.12 pg/mL; free thyroxine, 4.45 ng/dL), while thyrotropin (TSH) was suppressed (quadriplegia and deep coma. She gradually recovered. On day 36, she was discharged without any neurological symptoms or thyrotoxicosis. A 64-year-old woman taking lithium for bipolar disorder developed lithium toxicity in the setting of what seemed likely to be a recent onset of thyrotoxicosis due to silent thyroiditis. Thyrotoxicosis may be a contributing cause of lithium toxicity, particularly if it is abrupt in onset and even with cessation of lithium therapy if renal function is compromised. Thyroid function should be assessed immediately in patients with suspected lithium

  14. Effect of the Pacing Strategies on the Open Water 10km World Swimming Championships Performances.

    Science.gov (United States)

    Rodriguez, Luis; Veiga, Santiago

    2017-10-16

    The aim of the present research was 1) to compare the pacing strategies of different level open water swimmers during the 10km race of the FINA 2015 World Swimming Championships (WCH), and 2) to relate these pacing strategies to the race performance. Final and intermediate split times as well as intermediate race positions from the 10-kilometer race participants (69 men and 51 women) were collected from the public domain and were divided into five groups (G1 to G5) depending on their finishing positions. Medalists and finalists (G1 and G2, respectively) presented an even pacing profile with similar swimming velocities to the less successful swimmers (G3 to G5) on the initial and mid stages of the race but a 1.5-3% increase in swimming velocity in the last quarter of the race. This fast end spurt was largely related to the race performance and was not observed in the G3 and G4 (even-paced profile) or in the G5 (positive pacing profile) groups. Intermediate race positions and lap rankings were negatively related to finishing position indicating a delayed positioning of the most successful swimmers at 25%, 50% and 75% of race distance. The adoption of a conservative starting strategy by open water swimmers with a negative pacing profile and delayed partial positioning seems to increase the chances of overall race success as it allows a fast end spurt that is highly related to successful finishing race positions.

  15. MCTS self-paced training kit (exam 70-680) configuring Windows 7

    CERN Document Server

    McLean, Ian

    2010-01-01

    NOTE: The most recent printings of this title incorporate corrections to errors found in the earlier printings. This Self-Paced Training Kit is designed to help maximize your performance on 70-680, the required exam for the Microsoft® Certified Technology Specialist (MCTS): Windows 7, Configuration certification.This 2-in-1 kit includes the official Microsoft study guide, plus practice tests on CD to help you assess your skills. It comes packed with the tools and features exam candidates want most-including in-depth, self-paced training based on final exam content; rigorous, objective-by-obj

  16. International piping benchmarks: use of the simplified code PACE 2. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J T; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom); ed.

    1979-05-15

    This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost.

  17. Single lead atrial vs. dual chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Brandt, Niels H; Kirkfeldt, Rikke Esberg; Nielsen, Jens Cosedis

    2017-01-01

    Aims The DANPACE trial randomized patients with sick sinus syndrome (SSS) to single lead atrial (AAIR) or dual chamber (DDDR) pacemaker (PM). After 5 years follow-up, no difference in overall survival, stroke or heart failure (HF) was observed, whereas risk of atrial fibrillation (AF) and PM...... This register-based long-term follow-up study indicates that there is no difference in mortality among patients with SSS randomized to AAIR or DDDR pacing, even with very long follow-up. Nor is there any difference in risk of AF hospitalization, stroke or HF. The higher rate of pacing mode-change to DDDR...

  18. miR-133a Enhances the Protective Capacity of Cardiac Progenitors Cells after Myocardial Infarction

    Directory of Open Access Journals (Sweden)

    Alberto Izarra

    2014-12-01

    Full Text Available miR-133a and miR-1 are known as muscle-specific microRNAs that are involved in cardiac development and pathophysiology. We have shown that both miR-1 and miR-133a are early and progressively upregulated during in vitro cardiac differentiation of adult cardiac progenitor cells (CPCs, but only miR-133a expression was enhanced under in vitro oxidative stress. miR-1 was demonstrated to favor differentiation of CPCs, whereas miR-133a overexpression protected CPCs against cell death, targeting, among others, the proapoptotic genes Bim and Bmf. miR-133a-CPCs clearly improved cardiac function in a rat myocardial infarction model by reducing fibrosis and hypertrophy and increasing vascularization and cardiomyocyte proliferation. The beneficial effects of miR-133a-CPCs seem to correlate with the upregulated expression of several relevant paracrine factors and the plausible cooperative secretion of miR-133a via exosomal transport. Finally, an in vitro heart muscle model confirmed the antiapoptotic effects of miR-133a-CPCs, favoring the structuration and contractile functionality of the artificial tissue.

  19. Cardiac fusion and complex congenital cardiac defects in thoracopagus twins: diagnostic value of cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Park, Jeong-Jun [University of Ulsan College of Medicine, Asan Medical Center, Department of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Kim, Ellen Ai-Rhan [University of Ulsan College of Medicine, Asan Medical Center, Division of Neonatology, Department of Pediatrics, Seoul (Korea, Republic of); Won, Hye-Sung [University of Ulsan College of Medicine, Asan Medical Center, Department of Obstetrics and Gynecology, Seoul (Korea, Republic of)

    2014-09-15

    Most thoracopagus twins present with cardiac fusion and associated congenital cardiac defects, and assessment of this anatomy is of critical importance in determining patient care and outcome. Cardiac CT with electrocardiographic triggering provides an accurate and quick morphological assessment of both intracardiac and extracardiac structures in newborns, making it the best imaging modality to assess thoracopagus twins during the neonatal period. In this case report, we highlight the diagnostic value of cardiac CT in thoracopagus twins with an interatrial channel and complex congenital cardiac defects. (orig.)

  20. Alteration of cardiac glycoside positive inotropic action by modulators of protein synthesis and degradation

    International Nuclear Information System (INIS)

    Nosek, T.M.; Adams, R.J.

    1986-01-01

    Numerous membrane bound and cytoplasmic proteins participate in the cardiac expression of the positive inotropic action (PIA) of digitalis glycosides including the Na,K-ATPase (NKA). Exposure of the myocardium to an inhibitor of protein synthesis (cycloheximide, CYC) or of protein degradation (leupeptin, LEU) alters the PIA of ouabain in isolated, paced guinea pig papillary muscles (PM) in opposite ways. In vivo exposure to CYC for 3 hr resulted in a 30% depression of the in vitro PIA of ouabain at 1.7μM compared to control. In vivo exposure to LEU for 1 hr resulted in a 47% enhancement of the in vitro PIA of 1.7μM ouabain. Neither drug had an apparent effect on the ouabain PIA ED50. Neither CYC nor LEU exposure to PM in vitro affect resting or developed tension or the response of skinned PM to calcium. The mechanisms of the PIA alterations by CYC or LEU do not involve a direct effect on the digitalis receptor. Exposure of isolated cardiac sarcolemma enriched in NKA to 10-100μM CYC or LEU did not affect NKA activity or 3 H-ouabain binding. Although direct physicochemical effects of CYC or LEU may be involved in the alterations of the ouabain PIA, it is possible that modulation of the cellular levels or turnover rate of short-lived proteins may affect cardiac regulation of the digitalis PIA

  1. Is there an association between Fahr′s disease and cardiac conduction system disease?: A case report

    Directory of Open Access Journals (Sweden)

    Prashanth Panduranga

    2012-01-01

    Full Text Available Background: Fahr′s disease is a rare neurodegenerative disorder of unknown cause characterized by idiopathic basal ganglia calcification that is associated with neuropsychiatric and cognitive impairment. No case of Fahr′s disease with associated cardiac conduction disease has been described in the literature to date. The objective of this case report was to describe a young female with various cardiac conduction system abnormalities and bilateral basal ganglia calcifica-tion suggestive of Fahr′s disease. Case Report: A 19-year-old female was transferred to our hospital for a pacemaker insertion. Her past medical history included cognitive impairment and asymptomatic congenital complete heart block since birth. Her manifestations in-cluded cognitive impairment, tremors, rigidity, ataxia, bilateral basal ganglia calcification without clinical manifesta-tions of mitochondrial cytopathy. She also had right bundle branch block, left anterior fascicular block, intermittent complete heart block, atrial arrhythmias with advanced atrioventricular blocks and ventricular asystole manifested by Stokes-Adams seizures, which was diagnosed as epilepsy. Conclusions: According to our knowledge, this was the first case report of a su spected association between Fahr′s disease and isolated cardiac conduction system disease. In addition, this case illustrated that in patients with heart blocks and seizures, a diagnosis of epilepsy needs to be made with caution and such patients need further evaluations by a cardiologist or electrophysiologist to consider pacing and prevent future catastrophic events.

  2. An appropriate compression pace is important for securing the quality of hands-only CPR--a manikin study.

    Science.gov (United States)

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-09-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-second break between the sets. The percentage of compressions deeper than 5 cm at pace-110-g decreased significantly from 22.1 ± 4.7% in the first set to 16.7 ± 4.4%* in the second set (*p CPR.

  3. Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing

    DEFF Research Database (Denmark)

    Riahi, Sam; Nielsen, Jens Cosedis; Hjortshøj, Søren

    2012-01-01

    AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular...... patients (17%) with the leads in a non-apical position, HR 0.67, CI 0.45-1.00, P = 0.05. After adjustments this difference was non-significant. The incidence of HF was not associated with %VP (P = 0.57).CONCLUSION: In patients with SSS, HF was not associated with pacing mode, %VP, or ventricular lead...... localization. This suggests that DDDR pacing is safe in patients with SSS without precipitating HF....

  4. Multicenter, prospective, randomized safety and efficacy study of a new atrial-based managed ventricular pacing mode (MVP) in dual chamber ICDs.

    Science.gov (United States)

    Sweeney, Michael O; Ellenbogen, Kenneth A; Casavant, David; Betzold, Robert; Sheldon, Todd; Tang, Feng; Mueller, Megan; Lingle, John

    2005-08-01

    Ventricular desynchronization caused by right ventricular pacing may impair ventricular function and increase risk of heart failure (CHF), atrial fibrillation (AF), and death. Conventional DDD/R mode often results in high cumulative percentage ventricular pacing (Cum%VP). We hypothesized that a new managed ventricular pacing mode (MVP) would safely provide AAI/R pacing with ventricular monitoring and DDD/R during AV block (AVB) and reduce Cum%VP compared to DDD/R. MVP RAMware was downloaded in 181 patients with Marquis DR ICDs. Patients were initially randomized to either MVP or DDD/R for 1 month, then crossed over to the opposite mode for 1 month. ICD diagnostics were analyzed for cumulative percentage atrial pacing (Cum%AP), Cum%VP, and duration of DDD/R pacing for spontaneous AVB. Baseline characteristics included age 66 +/- 12 years, EF 36 +/- 14%, and NYHA Class II-III 36%. Baseline PR interval was 190 +/- 53 msec and programmed AV intervals (DDD/R) were 216 +/- 50 (paced)/189 +/- 53 (sensed) msec. Mean Cum%VP was significantly lower in MVP versus DDD/R (4.1 +/- 16.3 vs 73.8 +/- 32.5, P MVP were 85.0 and 99.9, respectively. Mean Cum%AP was not different between MVP versus DDD/R (48.7 +/- 38.5 vs 47.3 +/- 38.4, P = 0.83). During MVP overall time spent in AAI/R was 89.6% (intrinsic conduction), DDD/R 6.7% (intermittent AVB), and DDI/R 3.7% (AF). No adverse events were attributed to MVP. MVP safely achieves functional atrial pacing by limiting ventricular pacing to periods of intermittent AVB and AF in ICD patients, significantly reducing Cum%VP compared to DDD/R. MVP is a universal pacing mode that adapts to AVB and AF, providing both atrial pacing and ventricular pacing support when needed.

  5. Atrial pacing as an alternative to supine exercise (SE) in radionuclide ventriculography (RNV)

    International Nuclear Information System (INIS)

    Le Grand, V.; Wells, S.; O'Neil, W.W.; Jenkins, J.; Gross, M.D.; Vogel, R.

    1984-01-01

    Stress RNV is at times of limited value as many patients cannot achieve a sufficient pressure rate product (PRP). Atrial pacing is a noninvasive alternative to SE by bicycle ergometry. A swallowable electrode attached to a flexible wire is positioned in a retroatrial position in the esophagus and when connected to a variable output stimulator, variable rate (120, 140, 160 beats/min) atrial pacing ventriculography (APV) can be performed. RNV is performed in the sitting position at rest and at each pacing stage. APV was compared to SE RNV in 4 patients with coronary artery disease (CAD) and 3 normal volunteers (N). Tolerance to APV was excellent with adequate pacing. All subjects reported a minor sensation of chest burning. No arrhythmias occurred. At maximal APV mean PRP was 174 +- 26. The diastolic volumes in APV fell in all patients. Systolic volumes fell in N but not in CAD to APV. A flat EF response to APV was seen in both N and CAD patients. APV is an alternative to SE RNV although PRP remains low. Volume changes in APV are different than in SE RNV and in the interpretation of the results of APV in CAD, changes in systolic and diastolic volumes may be more important than the response of EF

  6. Sequential biventricular pacing improves regional contractility, longitudinal function and dyssynchrony in patients with heart failure and prolonged QRS

    Directory of Open Access Journals (Sweden)

    Ring Margareta

    2010-04-01

    Full Text Available Abstract Aims Biventricular pacing (BiP is an effective treatment in systolic heart failure (HF patients with prolonged QRS. However, approximately 35% of the patients receiving BiP are classified as non-responders. The aim of this study is to evaluate the acute effects of VV-optimization on systolic heart function. Methods Twenty-one HF patients aged 72 (46-88 years, QRS 154 (120-190 ms, were studied with echocardiography, Tissue Doppler Imaging (TDI and 3D-echo the first day after receiving a BiP device. TDI was performed; during simultaneous pacing (LV-lead pacing 4 ms before the RV-lead and during sequential pacing (LV 20 and 40 ms before RV and RV 20 and 40 ms before LV-lead pacing. Systolic heart function was studied by tissue tracking (TT for longitudinal function and systolic maximal velocity (SMV for regional contractility and signs of dyssynchrony assessed by time-delays standard deviation of aortic valve opening to SMV, AVO-SMV/SD and tissue synchronization imaging (TSI. Results The TT mean value preoperatively was 4,2 ± 1,5 and increased at simultaneous pacing to 5,0 ± 1,2 mm (p Conclusions VV-optimization in the acute phase improves systolic heart function more than simultaneous BiP pacing. Long-term effects should be evaluated in prospective randomized trials.

  7. Keeping Pace with K-12 Online Learning, 2016

    Science.gov (United States)

    Gemin, Butch; Pape, Larry

    2017-01-01

    "Keeping Pace with K-12 Online Learning 2016" marks the thirteenth consecutive year Evergreen has published its annual research of the K-12 education online learning market. The thirteen years of researching, writing and publishing this report represents a time of remarkable change. There has been a constant presence that has become the…

  8. Optimizing Classroom Instruction through Self-Paced Learning Prototype

    Science.gov (United States)

    Bautista, Romiro G.

    2015-01-01

    This study investigated the learning impact of self-paced learning prototype in optimizing classroom instruction towards students' learning in Chemistry. Two sections of 64 Laboratory High School students in Chemistry were used as subjects of the study. The Quasi-Experimental and Correlation Research Design was used in the study: a pre-test was…

  9. The pace of vocabulary growth helps predict later vocabulary skill

    Science.gov (United States)

    Rowe, Meredith L.; Raudenbush, Stephen W.; Goldin-Meadow, Susan

    2011-01-01

    Children vary widely in the rate at which they acquire words—some start slow and speed up, others start fast and continue at a steady pace. Do early developmental variations of this sort help predict vocabulary skill just prior to kindergarten entry? This longitudinal study starts by examining important predictors (SES, parent input, child gesture) of vocabulary growth between 14 and 46 months (n=62), and then uses growth estimates to predict children's vocabulary at 54 months. Velocity and acceleration in vocabulary development at 30 months predicted later vocabulary, particularly for children from low socioeconomic backgrounds. Understanding the pace of early vocabulary growth thus improves our ability to predict school readiness, and may help identify children at risk for starting behind. PMID:22235920

  10. Total artificial heart implantation for biventricular failure due to eosinophilic myocarditis.

    Science.gov (United States)

    Kawabori, Masashi; Kurihara, Chitaru; Miller, Yair; Heck, Kent A; Bogaev, Roberta C; Civitello, Andrew B; Cohn, William E; Frazier, O H; Morgan, Jeffrey A

    2017-09-01

    Idiopathic hypereosinophilic syndrome is a condition of unknown etiology characterized by proliferation of eosinophils and their infiltration into tissues. Although cardiac involvement is rare, eosinophilic myocarditis can lead to life-threating fulminant congestive heart failure. Treatment of patients with eosinophilic myocarditis is challenging as heart failure can be caused by biventricular dysfunction. To our knowledge, this is the first case reported in the literature describing a patient with acute severe biventricular heart failure caused by eosinophilic myocarditis with mural left ventricular apical thrombus who was successfully treated with implantation of a total artificial heart as a bridge to heart transplant.

  11. Primary prevention of sudden cardiac death of the young athlete: the controversy about the screening electrocardiogram and its innovative artificial intelligence solution.

    Science.gov (United States)

    Chang, Anthony C

    2012-03-01

    The preparticipation screening for athlete participation in sports typically entails a comprehensive medical and family history and a complete physical examination. A 12-lead electrocardiogram (ECG) can increase the likelihood of detecting cardiac diagnoses such as hypertrophic cardiomyopathy, but this diagnostic test as part of the screening process has engendered considerable controversy. The pro position is supported by argument that international screening protocols support its use, positive diagnosis has multiple benefits, history and physical examination are inadequate, primary prevention is essential, and the cost effectiveness is justified. Although the aforementioned myriad of justifications for routine ECG screening of young athletes can be persuasive, several valid contentions oppose supporting such a policy, namely, that the sudden death incidence is very (too) low, the ECG screening will be too costly, the false-positive rate is too high, resources will be allocated away from other diseases, and manpower is insufficient for its execution. Clinicians, including pediatric cardiologists, have an understandable proclivity for avoiding this prodigious national endeavor. The controversy, however, should not be focused on whether an inexpensive, noninvasive test such as an ECG should be mandated but should instead be directed at just how these tests for young athletes can be performed in the clinical imbroglio of these disease states (with variable genetic penetrance and phenotypic expression) with concomitant fiscal accountability and logistical expediency in this era of economic restraint. This monumental endeavor in any city or region requires two crucial elements well known to business scholars: implementation and execution. The eventual solution for the screening ECG dilemma requires a truly innovative and systematic approach that will liberate us from inadequate conventional solutions. Artificial intelligence, specifically the process termed "machine

  12. An Investigation on Exhaustion of SAP ERP Users: Influence of Pace of Change and Technostress

    Directory of Open Access Journals (Sweden)

    Prashanta Kumar Roy

    2017-10-01

    Full Text Available Despite recent growing research interest on ERP research, the understanding on ERP induced exhaustion is still limited. This study examines how the pace of change of ERP functionalities and interface causes exhaustion in workplace. For this purpose, we conducted an investigation on 128 ERP users from two different organizations in Bangladesh. We extended theory of technostress by integrating pace of change of ERP system. Result suggests that pace of change on ERP system significantly affect work-overload, work-life conflict and role ambiguity on ERP users. Result also shows that work-overload and role ambiguity are strong predictors for ERP induced exhaustion.

  13. Levodopa reinstates connectivity from prefrontal to premotor cortex during externally paced movement in Parkinson's disease

    DEFF Research Database (Denmark)

    Herz, Damian M; Siebner, Hartwig R; Hulme, Oliver J

    2014-01-01

    , which were externally paced at a rate of 0.5Hz. This required participants to align their movement velocity to the slow external pace. Patients were studied after at least 12-hour withdrawal of dopaminergic medication (OFF state) and after intake of the dopamine precursor levodopa (ON state) in order...

  14. Challenge of Engaging All Students via Self-Paced Interactive Electronic Learning Tutorials for Introductory Physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-01-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar…

  15. Child and Parental Outcomes Following Involvement in a Preventive Intervention: Efficacy of the PACE Program

    Science.gov (United States)

    Begle, Angela Moreland; Dumas, Jean E.

    2011-01-01

    This study evaluated whether engagement (i.e., attendance and quality of participation) in the Parenting our Children to Excellence (PACE) program predicted positive child and parent outcomes. PACE in an 8-week preventive intervention aimed at parents of preschool children. The study investigated the relation of engagement to outcomes in an…

  16. Early Right Ventricular Apical Pacing-Induced Gene Expression Alterations Are Associated with Deterioration of Left Ventricular Systolic Function

    Directory of Open Access Journals (Sweden)

    Haiyan Xu

    2017-01-01

    Full Text Available The chronic high-dose right ventricular apical (RVA pacing may have deleterious effects on left ventricular (LV systolic function. We hypothesized that the expression changes of genes regulating cardiomyocyte energy metabolism and contractility were associated with deterioration of LV function in patients who underwent chronic RVA pacing. Sixty patients with complete atrioventricular block and preserved ejection fraction (EF who underwent pacemaker implantation were randomly assigned to either RVA pacing (n=30 group or right ventricular outflow tract (RVOT pacing (n=30 group. The mRNA levels of OPA1 and SERCA2a were significantly lower in the RVA pacing group at 1 month’s follow-up (both p<0.001. Early changes in the expression of selected genes OPA1 and SERCA2a were associated with deterioration in global longitudinal strain (GLS that became apparent months later (p=0.002 and p=0.026, resp. The altered expressions of genes that regulate cardiomyocyte energy metabolism and contractility measured in the peripheral blood at one month following pacemaker implantation were associated with subsequent deterioration in LV dyssynchrony and function in patients with preserved LVEF, who underwent RVA pacing.

  17. An Appropriate Compression Pace is Important for Securing the Quality of Hands-only CPR : A manikin study

    OpenAIRE

    Shimizu, Yoshitaka; Tanigawa, Koichi; Ishikawa, Masami; Ouhara, Kazuhisa; Oue, Kana; Yoshinaka, Taiga; Kurihara, Hidemi; Irifune, Masahiro

    2014-01-01

    It is important to implement good quality chest compressions for cardiopulmonary resuscitation (CPR). This manikin study examined the effects of different compression rates on chest compression depth variables using a metronome sound guide. Fifty sixth-year dentistry students participated in the study. Each participant performed CPR at 3 different compression rates, 110, 100, and 90 compressions per min (pace-110-g, pace-100-g, and pace-90-g) for 2 consecutive one-minute sets with a ten-secon...

  18. Artificial intelligence

    CERN Document Server

    Hunt, Earl B

    1975-01-01

    Artificial Intelligence provides information pertinent to the fundamental aspects of artificial intelligence. This book presents the basic mathematical and computational approaches to problems in the artificial intelligence field.Organized into four parts encompassing 16 chapters, this book begins with an overview of the various fields of artificial intelligence. This text then attempts to connect artificial intelligence problems to some of the notions of computability and abstract computing devices. Other chapters consider the general notion of computability, with focus on the interaction bet

  19. Technetium 99m SESTAMIBI myocardial perfusion imaging: Comparison between treadmill, dipyridamole and trans-oesophageal atrial pacing 'stress' tests in normal subjects

    International Nuclear Information System (INIS)

    Primeau, M.; Taillefer, R.; Lambert, R.; Essiambre, R.; Honos, G.

    1991-01-01

    The purpose of this study was to determine the blood clearance, myocardial uptake and heart/lung and heart/liver ratios of technetium 99m methoxyisobutylisonitrile ( 99m Tc-SESTAMIBI) following 3 different types of cardiac stimulation in normal subjects: Treadmill stress (STRESS), intravenous administration of dipyridamole (DIP) and trans-oesophageal atrial pacing (TAP). Ten normal volunteers were submitted to 3 injections of 99m Tc-SESTAMIBI (10 mCi/70 kg, separated by an interval of 7 days) following STRESS (standard Bruce protocol), DIP (0.142 mg/kg.min during 4 min) and TAP procedures. Blood samples were collected from 1 to 60 min after each 99m Tc-SESTAMIBI injection. Planar imaging was performed at 5, 30 and 60 min. Blood retention (percentage of injected dose at 1 min) was 56%±4%, 24%±4% and 38%±6% for STRESS, DIP and TAP, respectively (P 99m Tc-SESTAMIBI. (orig.)

  20. PACE: A dynamic programming algorithm for hardware/software partitioning

    DEFF Research Database (Denmark)

    Knudsen, Peter Voigt; Madsen, Jan

    1996-01-01

    This paper presents the PACE partitioning algorithm which is used in the LYCOS co-synthesis system for partitioning control/dataflow graphs into hardware and software parts. The algorithm is a dynamic programming algorithm which solves both the problem of minimizing system execution time...

  1. MFTF-B PACE tests and final cost report

    International Nuclear Information System (INIS)

    Krause, K.H.; Kozman, T.A.; Smith, J.L.; Horan, R.J.

    1986-10-01

    The Mirror Fusion Test Facility (MFTF-B) construction project was successfully completed in February 1986, with the conclusion of the Plant and Capital Equipment (PACE) Tests. This series of tests, starting in September 1985 and running through February 1986, demonstrated the overall machine capabilities and special facilities accomplishments for the Mirror Fusion Test Facility Project

  2. The Use of a Quadripolar Left Ventricular Lead Increases Successful Implantation Rates in Patients with Phrenic Nerve Stimulation and/or High Pacing Thresholds Undergoing Cardiac Resynchronisation Therapy with Conventional Bipolar Leads

    Directory of Open Access Journals (Sweden)

    Marc-Alexander Ohlow, MD

    2013-03-01

    Conclusions: Excessively HPT and/or PNS are frequently encountered when conventional bipolar leads are used for CRT. A new quadripolar LV lead increases the rate of successful biventricular stimulation. Lower pacing threshold and freedom from PNS are maintained at follow-up.

  3. Effects of artificial gravity on the cardiovascular system: Computational approach

    Science.gov (United States)

    Diaz Artiles, Ana; Heldt, Thomas; Young, Laurence R.

    2016-09-01

    Artificial gravity has been suggested as a multisystem countermeasure against the negative effects of weightlessness. However, many questions regarding the appropriate configuration are still unanswered, including optimal g-level, angular velocity, gravity gradient, and exercise protocol. Mathematical models can provide unique insight into these questions, particularly when experimental data is very expensive or difficult to obtain. In this research effort, a cardiovascular lumped-parameter model is developed to simulate the short-term transient hemodynamic response to artificial gravity exposure combined with ergometer exercise, using a bicycle mounted on a short-radius centrifuge. The model is thoroughly described and preliminary simulations are conducted to show the model capabilities and potential applications. The model consists of 21 compartments (including systemic circulation, pulmonary circulation, and a cardiac model), and it also includes the rapid cardiovascular control systems (arterial baroreflex and cardiopulmonary reflex). In addition, the pressure gradient resulting from short-radius centrifugation is captured in the model using hydrostatic pressure sources located at each compartment. The model also includes the cardiovascular effects resulting from exercise such as the muscle pump effect. An initial set of artificial gravity simulations were implemented using the Massachusetts Institute of Technology (MIT) Compact-Radius Centrifuge (CRC) configuration. Three centripetal acceleration (artificial gravity) levels were chosen: 1 g, 1.2 g, and 1.4 g, referenced to the subject's feet. Each simulation lasted 15.5 minutes and included a baseline period, the spin-up process, the ergometer exercise period (5 minutes of ergometer exercise at 30 W with a simulated pedal cadence of 60 RPM), and the spin-down process. Results showed that the cardiovascular model is able to predict the cardiovascular dynamics during gravity changes, as well as the expected

  4. First clinical use of a bioprosthetic total artificial heart: report of two cases.

    Science.gov (United States)

    Carpentier, Alain; Latrémouille, Christian; Cholley, Bernard; Smadja, David M; Roussel, Jean-Christian; Boissier, Elodie; Trochu, Jean-Noël; Gueffet, Jean-Pierre; Treillot, Michèle; Bizouarn, Philippe; Méléard, Denis; Boughenou, Marie-Fazia; Ponzio, Olivier; Grimmé, Marc; Capel, Antoine; Jansen, Piet; Hagège, Albert; Desnos, Michel; Fabiani, Jean-Noël; Duveau, Daniel

    2015-10-17

    The development of artificial hearts in patients with end-stage heart disease have been confronted with the major issues of thromboembolism or haemorrhage. Since valvular bioprostheses are associated with a low incidence of these complications, we decided to use bioprosthetic materials in the construction of a novel artificial heart (C-TAH). We report here the device characteristics and its first clinical applications in two patients with end-stage dilated cardiomyopathy. The aim of the study was to evaluate safety and feasibility of the CARMAT TAH for patients at imminent risk of death from biventricular heart failure and not eligible for transplant. The C-TAH is an implantable electro-hydraulically actuated pulsatile biventricular pump. All components, batteries excepted, are embodied in a single device positioned in the pericardial sac after excision of the native ventricles. We selected patients admitted to hospital who were at imminent risk of death, having irreversible biventricular failure, and not eligible for heart transplantation, from three cardiac surgery centres in France. The C-TAH was implanted in two male patients. Patient 1, aged 76 years, had the C-TAH implantation on Dec 18, 2013; patient 2, aged 68 years, had the implantation on Aug 5, 2014. The cardiopulmonary bypass times for C-TAH implantation were 170 min for patient 1 and 157 min for patient 2. Both patients were extubated within the first 12 postoperative hours and had a rapid recovery of their respiratory and circulatory functions as well as a normal mental status. Patient 1 presented with a tamponade on day 23 requiring re-intervention. Postoperative bleeding disorders prompted anticoagulant discontinuation. The C-TAH functioned well with a cardiac output of 4·8-5·8 L/min. On day 74, the patient died due to a device failure. Autopsy did not detect any relevant thrombus formation within the bioprosthesis nor the different organs, despite a 50-day anticoagulant-free period. Patient 2

  5. A portable cadmium telluride multidetector probe for cardiac function monitoring

    CERN Document Server

    Arntz, Y; Dumitresco, B; Eclancher, B; Prat, V

    1999-01-01

    A new nuclear stethoscope based on a matrix of small CdTe semiconductor detectors has been developed for studying the cardiac performance by gamma ventriculography at the equilibrium, in rest and stress conditions, in the early and recovery phases of the coronary disease and to follow the long-term therapy. The light-weight probe consists of an array of 64 detectors 5x5x2 mm grouped in 16 independent units in a lead shielded aluminum box including 16 preamplifiers. The probe is connected to an electronic box containing DC power supply, 16 channel amplifiers, discriminators and counters, two analog-triggering ECG channels, and interface to a PC. The left ventricle activity is, preferentially, detected by using a low-resolution matching convergent collimator. A physical evaluation of the probe has been performed, both with static tests and dynamically with a hydraulic home-built model of beating heart ventricle paced by a rhythm simulator. The sum of the 16 detectors activity provided a radiocardiogram (RCG) wh...

  6. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    International Nuclear Information System (INIS)

    Murakoshi, Sadaaki

    1986-01-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 ± 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period. (author)

  7. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    Energy Technology Data Exchange (ETDEWEB)

    Murakoshi, Sadaaki

    1986-07-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 +- 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period.

  8. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    International Nuclear Information System (INIS)

    Karlstrom, L.; Kelly, K.A.

    1989-01-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction

  9. Ectopic jejunal pacemakers and gastric emptying after Roux gastrectomy: Effect of intestinal pacing

    Energy Technology Data Exchange (ETDEWEB)

    Karlstrom, L.; Kelly, K.A. (Mayo Clinic, Rochester, MN (USA))

    1989-11-01

    The aims of this study were to determine whether ectopic pacemakers are present after meals in the Roux limbs of dogs after vagotomy and Roux gastrectomy, whether these pacemakers slow gastric emptying of liquids or solids, and whether abolishing the pacemakers with electric pacing might speed any slow emptying that occurs. In six dogs that underwent vagotomy and Roux gastrectomy and in four dogs that underwent vagotomy and Billroth gastrectomy (controls), myoelectric activity of the Roux limb or duodenum was measured during gastric emptying of a 500 kcal mixed meal of 99mTc-labeled cooked egg and 111In-labeled milk. Roux dogs were tested with and without pacing of the Roux limb. Roux dogs showed ectopic pacemaker in the Roux limb that drove the pacesetter potentials of the limb in a reverse, or orad, direction during 57% of the postprandial recordings. Billroth dogs had no ectopic pacemakers (p less than 0.05). Liquids emptied more slowly in Roux dogs (half-life (t1/2) = 121 +/- 15 minutes) than in Billroth dogs (t1/2 = 43 +/- 9 minutes; p less than 0.05), but solids emptied similarly in both groups of dogs (t1/2 approximately 8 hours). Pacing the Roux limb abolished the ectopic pacemakers, restored the slow emptying of liquids to the more rapid rate found in the Billroth dogs (t1/2: paced Roux, 72 +/- 15 minutes; Billroth, 43 +/- 9 minutes; p greater than 0.05) and did not change emptying of solids. The conclusion was that ectopic pacemakers present in the Roux limb after vagotomy and Roux gastrectomy drove the limb in a reverse direction and slowed emptying of liquids after the operation. The defect was corrected by pacing the Roux limb in a forward direction.

  10. ERDA artificial heart program workshop. Final report, September 1, 1975--August 31, 1976

    International Nuclear Information System (INIS)

    Kantrowitz, A.; Altieri, F.; Beall, A.

    1976-08-01

    The major conclusions of the ERDA Artificial Heart Program Workshop are that the concept of a biologically compatible mechanical device which can totally replace the heart is sound, that such a device is needed as an alternative to cardiac transplantation and that its development is a realistic goal. The major recommendation of the committee is that an ERDA program with primary orientation toward development of a total heart replacement should continue, with assured funding about 50 percent higher than at present, for a minimum of 3 additional years at which time another major review should take place. To achieve better management of the program it is recommended that the present contract effort be reorganized under one prime contractor with responsibility for development and demonstration of the ERDA artificial heart system. The formation of a joint artificial heart advisory committee to improve coordination between ERDA and NHLI is also recommended. The committee suggests future policies and directions which it believes will lead to more effective use of funds available for specific aspects of the program. These include the nuclear heart source, engine, blood pump, biomaterials and overall system reliability. Possible future goals for the program are also proposed

  11. Symptoms of chronic fatigue syndrome/myalgic encephalopathy are not determined by activity pacing when measured by the chronic pain coping inventory.

    Science.gov (United States)

    Thompson, D P; Antcliff, D; Woby, S R

    2018-03-01

    Chronic fatigue syndrome/myalgic encephalopathy (CFS/ME) is a chronic illness which can cause significant fatigue, pain and disability. Activity pacing is frequently advocated as a beneficial coping strategy, however, it is unclear whether pacing is significantly associated with symptoms in people with CFS/ME. The first aim of this study was therefore to explore the cross-sectional associations between pacing and levels of pain, disability and fatigue. The second aim was to explore whether changes in activity pacing following participation in a symptom management programme were related to changes in clinical outcomes. Cross-sectional study exploring the relationships between pacing, pain, disability and fatigue (n=114) and pre-post treatment longitudinal study of a cohort of patients participating in a symptom management programme (n=35). Out-patient physiotherapy CFS/ME service. One-hundred and fourteen adult patients with CFS/ME. Pacing was assessed using the chronic pain coping inventory. Pain was measured using a Numeric Pain Rating Scale, fatigue with the Chalder Fatigue Scale and disability with the Fibromyalgia Impact Questionnaire. No significant associations were observed between activity pacing and levels of pain, disability or fatigue. Likewise, changes in pacing were not significantly associated with changes in pain, disability or fatigue following treatment. Activity pacing does not appear to be a significant determinant of pain, fatigue or disability in people with CFS/ME when measured with the chronic pain coping index. Consequently, the utility and measurement of pacing require further investigation. Copyright © 2017 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  12. Artificial Consciousness or Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    Spanache Florin

    2017-05-01

    Full Text Available Artificial intelligence is a tool designed by people for the gratification of their own creative ego, so we can not confuse conscience with intelligence and not even intelligence in its human representation with conscience. They are all different concepts and they have different uses. Philosophically, there are differences between autonomous people and automatic artificial intelligence. This is the difference between intelligence and artificial intelligence, autonomous versus automatic. But conscience is above these differences because it is neither conditioned by the self-preservation of autonomy, because a conscience is something that you use to help your neighbor, nor automatic, because one’s conscience is tested by situations which are not similar or subject to routine. So, artificial intelligence is only in science-fiction literature similar to an autonomous conscience-endowed being. In real life, religion with its notions of redemption, sin, expiation, confession and communion will not have any meaning for a machine which cannot make a mistake on its own.

  13. Pacemaker Use in New Zealand - Data From the New Zealand Implanted Cardiac Device Registry (ANZACS-QI 15).

    Science.gov (United States)

    Larsen, P D; Kerr, A J; Hood, M; Harding, S A; Hooks, D; Heaven, D; Lever, N A; Sinclair, S; Boddington, D; Tang, E W; Swampillai, J; Stiles, M K

    2017-03-01

    The New Zealand Cardiac Implanted Device Registry (Device) has recently been developed under the auspices of the New Zealand Branch of the Cardiac Society of Australia and New Zealand. This study describes the initial Device registry cohort of patients receiving a new pacemaker, their indications for pacing and their perioperative complications. The Device Registry was used to audit patients receiving a first pacemaker between 1 st January 2014 and 1 st June 2015. We examined 1611 patients undergoing first pacemaker implantation. Patients were predominantly male (59%), and had a median age of 70 years. The most common symptom for pacemaker implantation was syncope (39%), followed by dizziness (30%) and dyspnoea (12%). The most common aetiology for a pacemaker was a conduction tissue disorder (35%), followed by sinus node dysfunction (22%). Atrioventricular (AV) block was the most common ECG abnormality, present in 44%. Dual chamber pacemakers were most common (62%), followed by single chamber ventricular pacemakers (34%), and cardiac resynchronisation therapy - pacemakers (CRT-P) (2%). Complications within 24hours of the implant procedure were reported in 64 patients (3.9%), none of which were fatal. The most common complication was the need for reoperation to manipulate a lead, occurring in 23 patients (1.4%). This is the first description of data entered into the Device registry. Patients receiving a pacemaker were younger than in European registries, and there was a low use of CRT-P devices compared to international rates. Complications rates were low and compare favourably to available international data. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  14. Challenge of Helping Introductory Physics Students Transfer Their Learning by Engaging with a Self-Paced Learning Tutorial

    Directory of Open Access Journals (Sweden)

    Emily Megan Marshman

    2018-03-01

    Full Text Available With advances in digital technology, research-validated self-paced learning tools can play an increasingly important role in helping students with diverse backgrounds become good problem solvers and independent learners. Thus, it is important to ensure that all students engage with self-paced learning tools effectively in order to learn the content deeply, develop good problem-solving skills, and transfer their learning from one context to another. Here, we first provide an overview of a holistic framework for engaging students with self-paced learning tools so that they can transfer their learning to solve novel problems. The framework not only takes into account the features of the self-paced learning tools but also how those tools are implemented, the extent to which the tools take into account student characteristics, and whether factors related to students’ social environments are accounted for appropriately in the implementation of those tools. We then describe an investigation in which we interpret the findings using the framework. In this study, a research-validated self-paced physics tutorial was implemented in both controlled one-on-one interviews and in large enrollment, introductory calculus-based physics courses as a self-paced learning tool. We find that students who used the tutorial in a controlled one-on-one interview situation performed significantly better on transfer problems than those who used it as a self-paced learning tool in the large-scale implementation. The findings suggest that critically examining and taking into account how the self-paced tools are implemented and incentivized, student characteristics including their self-regulation and time-management skills, and social and environmental factors can greatly impact the extent and manner in which students engage with these learning tools. Getting buy in from students about the value of these tools and providing appropriate support while implementing them is

  15. Is right ventricular mid-septal pacing superior to apical pacing in patients with high degree atrio-ventricular block and moderately depressed left ventricular function?

    Science.gov (United States)

    Chen, Kang; Mao, Ye; Liu, Shao-hua; Wu, Qiong; Luo, Qing-zhi; Pan, Wen-qi; Jin, Qi; Zhang, Ning; Ling, Tian-you; Chen, Ying; Gu, Gang; Shen, Wei-feng; Wu, Li-qun

    2014-06-01

    We are aimed to investigate whether right ventricular mid-septal pacing (RVMSP) is superior to conventional right ventricular apical pacing (RVAP) in improving clinical functional capacity and left ventricular ejection fraction (LVEF) for patients with high-degree atrio-ventricular block and moderately depressed left ventricle (LV) function. Ninety-two patients with high-degree atrio-ventricular block and moderately reduced LVEF (ranging from 35% to 50%) were randomly allocated to RVMSP (n=45) and RVAP (n=47). New York Heart Association (NYHA) functional class, echocardiographic LVEF, and distance during a 6-min walk test (6MWT) were determined at 18 months after pacemaker implantation. Serum levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) were measured using an enzyme-linked immunosorbent assay (ELISA) kit. Compared with baseline, NYHA functional class remained unchanged at 18 months, distance during 6MWT (485 m vs. 517 m) and LVEF (36.7% vs. 41.8%) were increased, but BNP levels were reduced (2352 pg/ml vs. 710 pg/ml) in the RVMSP group compared with those in the RVAP group, especially in patients with LVEF 35%-40% (for all comparisons, Pfunction capacity and LV function measurements were not significantly changed in patients with RVAP, despite the pacing measurements being similar in both groups, such as R-wave amplitude and capture threshold. RVMSP provides a better clinical utility, compared with RVAP, in patients with high-degree atrioventricular block and moderately depressed LV function whose LVEF levels ranged from 35% to 40%.

  16. Deviation from goal pace, body temperature and body mass loss as predictors of road race performance.

    Science.gov (United States)

    Adams, William M; Hosokawa, Yuri; Belval, Luke N; Huggins, Robert A; Stearns, Rebecca L; Casa, Douglas J

    2017-03-01

    The purpose of this study was to examine the relationship between pacing, gastrointestinal temperature (T GI ), and percent body mass loss (%BML) on relative race performance during a warm weather 11.3km road race. Observational study of a sample of active runners competing in the 2014 Falmouth Road Race. Participants ingested a T GI pill and donned a GPS enabled watch with heart rate monitoring capabilities prior to the start of the race. Percent off predicted pace (% OFF ) was calculated for seven segments of the race. Separate linear regression analyses were used to assess the relationship between pace, T ​GI , and %BML on relative race performance. One-way ANOVA was used to analyse post race T GI (≥40°C vs 0.05). There was a trend in a slower pace (p=0.055) and greater % OFF (p=0.056) in runners finishing the race with a T GI >40°C. Overall, finish time was influenced by greater variations in pace during the first two miles of the race. In addition, runners who minimized fluid losses and had lower T GI were associated with meeting self-predicted goals. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  17. Cardiac tamponade: contrast reflux as an indicator of cardiac chamber equalization

    Directory of Open Access Journals (Sweden)

    Nauta Foeke Jacob

    2012-05-01

    Full Text Available Abstract Background Traumatic hemopericardium remains a rare entity; it does however commonly cause cardiac tamponade which remains a major cause of death in traumatic blunt cardiac injury. Objectives We present a case of blunt chest trauma complicated by cardiac tamponade causing cardiac chamber equalization revealed by reflux of contrast. Case report A 29-year-old unidentified male suffered blunt chest trauma in a motor vehicle collision. Computed tomography (CT demonstrated a periaortic hematoma and hemopericardium. Significant contrast reflux was seen in the inferior vena cava and hepatic veins suggesting a change in cardiac chamber pressures. After intensive treatment including cardiac massage this patient expired of cardiac arrest. Conclusion Reflux of contrast on CT imaging can be an indicator of traumatic cardiac tamponade.

  18. Percutaneous removal of a pacing electrode

    International Nuclear Information System (INIS)

    Hoehne, U.; Schild, H.; Hake, U.

    1989-01-01

    The large number of pace-makers introduced transvenously has resulted in increasing the number of complications, amongst which infections and dislocations are prominent. It is usually necessary to remove the electrode, which can be attempted percutaneously by using a Dormia basket, a loop or forceps. Amongst the complications of this procedure are tears to the myocardium, with the risk of pericardial tamponade, or tears of the tricuspid valve leading to tricuspid insufficiency. Consequently, thoracic surgical intervention should be available if necessary. Four successful procedures are described. (orig.) [de

  19. Time perception, pacing and exercise intensity: maximal exercise distorts the perception of time

    OpenAIRE

    Edwards, A. M.; McCormick, A.

    2017-01-01

    Introduction\\ud \\ud Currently there are no data examining the impact of exercise on the perception of time, which is surprising as optimal competitive performance is dependent on accurate pacing using knowledge of time elapsed.\\ud \\ud \\ud Methods\\ud \\ud With institutional ethics approval, 12 recreationally active adult participants (f = 7, m = 5) undertook both 30 s Wingate cycles and 20 min (1200 s) rowing ergometer bouts as short and long duration self-paced exercise trials, in each of thre...

  20. Three-dimensional engineered heart tissue from neonatal rat cardiac myocytes.

    Science.gov (United States)

    Zimmermann, W H; Fink, C; Kralisch, D; Remmers, U; Weil, J; Eschenhagen, T

    2000-04-05

    A technique is presented that allows neonatal rat cardiac myocytes to form spontaneously and coherently beating 3-dimensional engineered heart tissue (EHT) in vitro, either as a plane biconcaval matrix anchored at both sides on Velcro-coated silicone tubes or as a ring. Contractile activity was monitored in standard organ baths or continuously in a CO(2) incubator for up to 18 days (=26 days after casting). Long-term measurements showed an increase in force between days 8 and 18 after casting and stable forces thereafter. At day 10, the twitch amplitude (TA) of electrically paced EHTs (average length x width x thickness, 11 x 6 x 0.4 mm) was 0.51 mN at length of maximal force development (L(max)) and a maximally effective calcium concentration. EHTs showed typical features of neonatal rat heart: a positive force-length and a negative force-frequency relation, high sensitivity to calcium (EC(50) 0.24 mM), modest positive inotropic (increase in TA by 46%) and pronounced positive lusitropic effect of isoprenaline (decrease in twitch duration by 21%). Both effects of isoprenaline were sensitive to the muscarinic receptor agonist carbachol in a pertussis toxin-sensitive manner. Adenovirus-mediated gene transfer of beta-galactosidase into EHTs reached 100% efficiency. In summary, EHTs retain many of the physiological characteristics of rat cardiac tissue and allow efficient gene transfer with subsequent force measurement. Copyright 2000 John Wiley & Sons, Inc.

  1. Regulation of cardiac remodeling by cardiac Na/K-ATPase isoforms

    Directory of Open Access Journals (Sweden)

    Lijun Catherine Liu

    2016-09-01

    Full Text Available Cardiac remodeling occurs after cardiac pressure/volume overload or myocardial injury during the development of heart failure and is a determinant of heart failure. Preventing or reversing remodeling is a goal of heart failure therapy. Human cardiomyocyte Na+/K+-ATPase has multiple α isoforms (1-3. The expression of the α subunit of the Na+/K+-ATPase is often altered in hypertrophic and failing hearts. The mechanisms are unclear. There are limited data from human cardiomyocytes. Abundant evidences from rodents show that Na+/K+-ATPase regulates cardiac contractility, cell signaling, hypertrophy and fibrosis. The α1 isoform of the Na+/K+-ATPase is the ubiquitous isoform and possesses both pumping and signaling functions. The α2 isoform of the Na+/K+-ATPase regulates intracellular Ca2+ signaling, contractility and pathological hypertrophy. The α3 isoform of the Na+/K+-ATPase may also be a target for cardiac hypertrophy. Restoration of cardiac Na+/K+-ATPase expression may be an effective approach for prevention of cardiac remodeling. In this article, we will overview: (1 the distribution and function of isoform specific Na+/K+-ATPase in the cardiomyocytes. (2 the role of cardiac Na+/K+-ATPase in the regulation of cell signaling, contractility, cardiac hypertrophy and fibrosis in vitro and in vivo. Selective targeting of cardiac Na+/K+-ATPase isoform may offer a new target for the prevention of cardiac remodeling.

  2. Failure of communication and capture: The perils of temporary unipolar pacing system.

    Science.gov (United States)

    Sahinoglu, Efe; Wool, Thomas J; Wool, Kenneth J

    2015-06-01

    We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  3. Low settings of the ventricular pacing output in patients dependent on a pacemaker: are they really safe?

    Science.gov (United States)

    Schuchert, Andreas; Frese, Jens; Stammwitz, Ekkehard; Novák, Miroslav; Schleich, Arthur; Wagner, Stefan M; Meinertz, Thomas

    2002-06-01

    It is generally acknowledged that pacemaker output must be adjusted with a 100% voltage safety margin above the pacing threshold to avoid ineffective pacing, especially in patients dependent on pacemakers. The aim of this prospective crossover study was to assess the beat-to-beat safety of low outputs in patients who are dependent on a pacemaker between 2 follow-up examinations. The study included 12 patients who had received a DDD pacemaker with an automatic beat-to-beat capture verification function. The ventricular output at 0.4 milliseconds pulse duration was programmed independently of the actual pacing threshold in a crossover randomization to 1.0 V, 1.5 V, and 2.5 V for 6 weeks each. At each follow-up, the diagnostic counters were interrogated and the pacing threshold at 0.4 milliseconds was determined in 0.1-V steps. The diagnostic pacemaker counters depict the frequency of back-up pulses delivered because of a loss of capture. During the randomization to 1.0-V output, we evaluated whether the adjustment of the output under consideration of the >100% voltage safety margin reduced the frequency of back-up pulses. Pacing thresholds at the randomization to 1.0-V, 1.5-V, and 2.5-V output were not significantly different, with 0.7 +/- 0.3 V at 2.5-V output, 0.6 +/- 0.2 V at 1.5-V output, and 0.6 +/- 0.2 V at 1.0-V output. The frequency of back-up pulses was similar at 2.5-V and 1.5-V output, 2.2% +/- 1.9% and 2.0% +/- 2.0%, respectively. The frequency of back-up pulses significantly increased at 1.0-V output to 5.8% +/- 6.4% (P 5% of the time between the 2 follow-ups were observed in no patient at 2.5 V, in 1 patient at 1.5 V, and in 5 patients at 1.0 V. At the randomization to the 1.0-V output, 6 patients had pacing thresholds of 0.5 V or less, and 6 patients had pacing thresholds >0.5 V. The frequency of back-up pulses in the 2 groups was not significantly different, 6.4% +/- 8.6% and 5.7% +/- 2.6%. The frequency of back-up pulses was significantly higher at 1

  4. Initial Efficacy of a Cardiac Rehabilitation Transition Program: Cardiac TRUST

    Science.gov (United States)

    Zullo, Melissa; Boxer, Rebecca; Moore, Shirley M.

    2012-01-01

    Patients recovering from cardiac events are increasingly using postacute care, such as home health care and skilled nursing facility services. The purpose of this pilot study was to test the initial efficacy, feasibility, and safety of a specially designed postacute care transitional rehabilitation intervention for cardiac patients. Cardiac Transitional Rehabilitation Using Self- Management Techniques (Cardiac TRUST) is a family-focused intervention that includes progressive low-intensity walking and education in self-management skills to facilitate recovery following a cardiac event. Using a randomized two-group design, exercise self-efficacy, steps walked, and participation in an outpatient cardiac rehabilitation program were compared in a sample of 38 older adults; 17 who received the Cardiac TRUST program and 21 who received usual care only. At discharge from postacute care, the intervention group had a trend for higher levels of self-efficacy for exercise outcomes (X=39.1, SD=7.4) than the usual care group (X=34.5; SD=7.0) (t-test 1.9, p=.06). During the 6 weeks following discharge, compared with the usual care group, the intervention group had more attendance in out-patient cardiac rehabilitation (33% compared to 11.8%, F=7.1, p=.03) and a trend toward more steps walked during the first week (X=1,307, SD=652 compared to X=782, SD=544, t-test 1.8, p=.07). The feasibility of the intervention was better for the home health participants than for those in the skilled nursing facility and there were no safety concerns. The provision of cardiac-focused rehabilitation during postacute care has the potential to bridge the gap in transitional services from hospitalization to outpatient cardiac rehabilitation for these patients at high risk for future cardiac events. Further evidence of the efficacy of Cardiac TRUST is warranted. PMID:22084960

  5. How Pacing of Multimedia Instructions Can Influence Modality Effects: A Case of Superiority of Visual Texts

    Science.gov (United States)

    Stiller, Klaus D.; Freitag, Annika; Zinnbauer, Peter; Freitag, Christian

    2009-01-01

    "Present text accompanying pictures aurally to promote learning" is a well established principle of instructional design. But recently, it was shown that under certain conditions visual texts can be preferable. Instructional pacing seems to be one of these conditions that mediate effects. Especially, enabling learners to pace an…

  6. Effect of "U-Pace" Instruction on Academic Success, Learning, and Perceptions in Younger and Older Undergraduates

    Science.gov (United States)

    Fleming, Raymond; Barth, Dylan; Weber, Nicole; Pedrick, Laura E.; Kienzler, Sarah E.; Reddy, Diane M.

    2018-01-01

    A randomized controlled trial was conducted to determine the efficacy of "U-Pace" instruction for older undergraduates, ages 25 and older, and younger undergraduates, ages 18 to 24. Additionally, change in learner perceptions across the semester, an outcome not reported in the literature on "U-Pace" instruction, was…

  7. Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

    International Nuclear Information System (INIS)

    King, Martin; Rodgers, Zachary; Giger, Maryellen L.; Bardo, Dianna M. E.; Patel, Amit R.

    2010-01-01

    Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed

  8. Keeping Pace with K-12 Online & Blended Learning: An Annual Review of Policy and Practice, 2013

    Science.gov (United States)

    Watson, John; Murin, Amy; Vashaw, Lauren; Gemin, Butch; Rapp, Chris

    2013-01-01

    This is the 10th annual "Keeping Pace" report. "Keeping Pace" has several goals: (1) add to the body of knowledge about online education policy and practice, and make recommendations for advances; (2) serve as a reference source for information about programs and policies across the country, both for policymakers and…

  9. Clinical application of transvenous temporary cardiac pacemaker in performing extra-cranial carotid angiography and stent implantation

    International Nuclear Information System (INIS)

    Liu Juan; Yao Guoen; Zhou Huadong; Jiang Xiaojiang; Chen Qiao

    2012-01-01

    Objective: To assess the safety and effectiveness of transvenous temporary cardiac pacemaker in preventing hemodynamic instability occurred during the perioperative period of extra-cranial carotid angiography and stent implantation. Methods: Preoperative install of temporary cardiac pacemaker via left femoral vein was carried out in 41 patients who were at high risk for developing hemodynamic instability, which was followed by extra-cranial carotid angiography and stent implantation. The pacing rhythm of the pacemaker was fixed at 60 beats/min. During and after the procedure the patients were under close observation for the signs of discomfort symptoms as well as the changes in blood pressure and heart rate. The working condition of the pacemaker was also monitored. Results: All the installed pacemakers were technically and hemodynamically effective in producing electrical ventricular responses in all 25 patients who had received balloon dilatation of carotid in advance. Transient pacemaker activation appeared in 25 patients. The longest activation time was one day. During pacemaker activation, one patient developed symptomatic hypotension. The longest duration of hypotension lasted for 4 days. No pacemaker-related or procedure-related complications occurred. Conclusion: Hemodynamic instability is a common complication occurred during perioperative period of extra-cranial carotid angiography and stent implantation. As a prophylactic measure, preoperative placement of temporary cardiac pacemaker can promptly and effectively correct the hemodynamic disorders and prevent perioperative complications such as stroke, etc. Therefore, this technique is worth employing in clinical practice, and it is especially useful for patients with high risks. (authors)

  10. Surface ECG and Fluoroscopy are Not Predictive of Right Ventricular Septal Lead Position Compared to Cardiac CT.

    Science.gov (United States)

    Rowe, Matthew K; Moore, Peter; Pratap, Jit; Coucher, John; Gould, Paul A; Kaye, Gerald C

    2017-05-01

    Controversy exists regarding the optimal lead position for chronic right ventricular (RV) pacing. Placing a lead at the RV septum relies upon fluoroscopy assisted by a surface 12-lead electrocardiogram (ECG). We compared the postimplant lead position determined by ECG-gated multidetector contrast-enhanced computed tomography (MDCT) with the position derived from the surface 12-lead ECG. Eighteen patients with permanent RV leads were prospectively enrolled. Leads were placed in the RV septum (RVS) in 10 and the RV apex (RVA) in eight using fluoroscopy with anteroposterior and left anterior oblique 30° views. All patients underwent MDCT imaging and paced ECG analysis. ECG criteria were: QRS duration; QRS axis; positive or negative net QRS amplitude in leads I, aVL, V1, and V6; presence of notching in the inferior leads; and transition point in precordial leads at or after V4. Of the 10 leads implanted in the RVS, computed tomography (CT) imaging revealed seven to be at the anterior RV wall, two at the anteroseptal junction, and one in the true septum. For the eight RVA leads, four were anterior, two septal, and two anteroseptal. All leads implanted in the RVS met at least one ECG criteria (median 3, range 1-6). However, no criteria were specific for septal position as judged by MDCT. Mean QRS duration was 160 ± 24 ms in the RVS group compared with 168 ± 14 ms for RVA pacing (P = 0.38). We conclude that the surface ECG is not sufficiently accurate to determine RV septal lead tip position compared to cardiac CT. © 2017 Wiley Periodicals, Inc.

  11. Magnetic resonance imaging in patients with cardiac pacemakers: In vitro-and vivo-evaluation at 0.5 Tesla

    International Nuclear Information System (INIS)

    Sommer, T.; Block, W.; Schild, H.; Schimpf, R.; Smekal, A. v.; Wolke, S.; Gieseke, J.; Schneider, C.; Funke, H.D.

    1998-01-01

    Purpose: MRI is currently regarded as absolutely contraindicated in patients with implanted cardiac pacemakers. In this prospective study safety and feasibility of MRI in patients with new generation pacemakers (PM) was evaluated in vitro and in vivo. Results: In the static magnetic field all PM switched to the asynchronous mode due to activation of the Reed switch, resulting in continuous pacing at a fixed rate. In three PM models in vitro, however, after activation of the Reed switch, there was a software-induced switch back to the demand mode. In these PM inhibition and triggering were observed after starting the MRI scan due to influence of the pulsed magnetic fields. PM program changes, damage of PM components, dislocation/torque of the PM and rapid pacing of the PM were observed neither in vitro nor in vivo. Atrial and ventricular stimulation thresholds remained unchanged. Conclusion: MRI at 0.5 Tesla should not be regarded as absolutely contraindicated in patients with implanted new generation PM. However, knowledge of the behaviour of the specific PM model in static and pulsed magnetic fields is required, if necessary also changes of the PM program prior of the MRI exam, continuous ECG monitoring and cardiological stand-by. (orig.) [de

  12. Myocardial ischemia detection by artificial intelligence interpretation of Tl-201 tomograms

    International Nuclear Information System (INIS)

    Herbst, M.D.; Garcia, E.V.; Cooke, C.D.; Folks, R.D.; Ezquerra, N.F.

    1989-01-01

    This paper reports on an expert system environment which automatically assigned certainty factors to abnormal regions in stress and delayed myocardial thallium-201 polar bulls-eye plots. MYCIN-type algorithms propagated certainty factors for the presence, location, and character of each coronary lesion. Ninety-four previously validated rules that considered only stress perfusion defects spawned 91 new rules considering tracer redistribution. Fifteen new rules assessed vascular territories for the presence and location of fixed or reversible defects. This artificial intelligence tool can provide novice readers of cardiac T1-201 studies automatic, consistent, objective, and justified interpretations that consider artifacts, coronary territory overlap, and multiple defects

  13. Pilot trial of an age-paced parenting newsletter.

    Science.gov (United States)

    Keane, Brigid; Waterston, Tony; McConachie, Helen; Towner, Elizabeth; Cook, Margaret; Birks, Eileen

    2005-10-01

    Supporting parents in the first three years of a child's life has the potential to produce successful outcomes. Present government initiatives such as Sure Start focus on this age group. An American educational intervention, in the style of a monthly newsletter, was adapted for use in the UK for parents of young children. Topics were presented in an easy-to-read format and focused on infant emotional development, parent interaction and play. Newsletters, called Baby Express were posted at monthly intervals to the family home providing age-paced information which could meet the specific needs of parents at that stage of their child's life. The aim of the study was to determine the applicability of the newsletter to UK parents and evaluate their satisfaction. Sixty home-based interviews were conducted and 95 per cent of mothers reported reading all or part of the newsletter. Changes in parenting style were spontaneously reported by 28 per cent of mothers. This study found that an aged-paced parenting newsletter was an acceptable and useful method of supporting parents in the early months of a child's life and promotes positive changes in parenting behaviour.

  14. Design Recommendations for Self-Paced Online Faculty Development Courses

    Science.gov (United States)

    Rizzuto, Melissa

    2017-01-01

    An increased need for self-paced, online professional development opportunities in higher education has emerged from a variety of factors including dispersed geographic locations of faculty, full teaching loads, and institutional evaluation requirements. This article is a report of the examination of the design and evaluation of a self-paced…

  15. Financial audit of antitachycardia pacing for the control of recurrent supraventricular tachycardia.

    Science.gov (United States)

    Griffith, M J; Bexton, R S; McComb, J M

    1993-03-01

    To assess the financial implications of antitachycardia pacing in patients with frequent supraventricular tachycardia. Intertach pacemakers were implanted in 25 patients (mean age 47 years, five men): 22 had atrioventricular nodal reentry tachycardia. The patients had failed a mean of 4.9 (range zero to eight) drugs and had been admitted to hospital 3.7 (zero to 31) times over a symptomatic period of 13.9 years (two months to 54 years). The mean admission time for implantation was 2.8 (two to seven) days. One patient with Wolff-Parkinson-White syndrome subsequently underwent surgery. Infection occurred in two patients, and pain over the pacemaker required its resiting in two. Two patients have had one admission each for tachycardia. Six patients remain on anti-arrhythmic drugs. Costs were calculated including value added tax, capital charges, and allocated overheads. The cost a year before pacing was 1174 pounds including drug costs, clinic visits, and hospital admissions. The mean cost of pacemaker implantation was 3364.22 pounds, including the pacemaker and lead, admission and procedure, readmissions and first pacing check. Subsequent annual follow up cost was 73.72 pounds including annual clinic visits and drug costs. The cost of pacing is 4241 pounds whereas medical management costs 7044 pounds assuming pacemaker life of six years: with a 10 year life the cost is 4537 pounds compared with 11,740 pounds: with a 12 year life the cost is 4685 pounds compared with 14,088 pounds. The excess cost of implantation of an antitachycardia pacemaker is minimal in patients with frequent supraventricular tachycardia despite drug treatment and is justified by excellent control of symptoms and reduction of drug use and hospital admissions.

  16. Pacing Lead-Induced Granuloma in the Atrium: A Foreign Body Reaction to Polyurethane

    Directory of Open Access Journals (Sweden)

    Shinagawa Yoko

    2013-01-01

    Full Text Available We described a case of an 82-year-old male who presented with a granuloma entrapping the polyurethane-coated pacing lead at the site of contact on the atrium. He had been paced for 8 years without symptoms or signs suggestive of an allergic reaction to the pacemaker system and died from thrombosis of the superior mesenteric artery and heart failure. A histological examination of the nodule showed an incidental granuloma with multinucleated giant cells. No granuloma was found in the heart or the lung.

  17. Financing the Business. PACE Revised. Level 1. Unit 8. Research & Development Series No. 240AB8.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on financing a business, the eighth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  18. Self-Paced Prioritized Curriculum Learning With Coverage Penalty in Deep Reinforcement Learning.

    Science.gov (United States)

    Ren, Zhipeng; Dong, Daoyi; Li, Huaxiong; Chen, Chunlin; Zhipeng Ren; Daoyi Dong; Huaxiong Li; Chunlin Chen; Dong, Daoyi; Li, Huaxiong; Chen, Chunlin; Ren, Zhipeng

    2018-06-01

    In this paper, a new training paradigm is proposed for deep reinforcement learning using self-paced prioritized curriculum learning with coverage penalty. The proposed deep curriculum reinforcement learning (DCRL) takes the most advantage of experience replay by adaptively selecting appropriate transitions from replay memory based on the complexity of each transition. The criteria of complexity in DCRL consist of self-paced priority as well as coverage penalty. The self-paced priority reflects the relationship between the temporal-difference error and the difficulty of the current curriculum for sample efficiency. The coverage penalty is taken into account for sample diversity. With comparison to deep Q network (DQN) and prioritized experience replay (PER) methods, the DCRL algorithm is evaluated on Atari 2600 games, and the experimental results show that DCRL outperforms DQN and PER on most of these games. More results further show that the proposed curriculum training paradigm of DCRL is also applicable and effective for other memory-based deep reinforcement learning approaches, such as double DQN and dueling network. All the experimental results demonstrate that DCRL can achieve improved training efficiency and robustness for deep reinforcement learning.

  19. Diagnostic accuracy of metronome-paced tachypnea to detect dynamic hyperinflation

    NARCIS (Netherlands)

    Lahaije, A.J.M.C.; Willems, L.M.; Hees, H.W. van; Dekhuijzen, P.N.R.; Helvoort, H.A.C. van; Heijdra, Y.F.

    2013-01-01

    INTRODUCTION: This prospective study was carried out to investigate if metronome-paced tachypnea (MPT) can serve as an accurate diagnostic tool to identify patients with chronic obstructive pulmonary disease (COPD) who are susceptible to develop dynamic hyperinflation during exercise. Commonly, this

  20. Amplitude and phase dynamics associated with acoustically paced finger tapping

    NARCIS (Netherlands)

    Boonstra, T.W.; Daffertshofer, A.; Peper, C.E.; Beek, P.J.

    2006-01-01

    To gain insight into the brain activity associated with the performance of an acoustically paced synchronization task, we analyzed the amplitude and phase dynamics inherent in magnetoencephalographic (MEG) signals across frequency bands in order to discriminate between evoked and induced responses.

  1. Cardiac tumors: optimal cardiac MR sequences and spectrum of imaging appearances.

    LENUS (Irish Health Repository)

    O'Donnell, David H

    2012-02-01

    OBJECTIVE: This article reviews the optimal cardiac MRI sequences for and the spectrum of imaging appearances of cardiac tumors. CONCLUSION: Recent technologic advances in cardiac MRI have resulted in the rapid acquisition of images of the heart with high spatial and temporal resolution and excellent myocardial tissue characterization. Cardiac MRI provides optimal assessment of the location, functional characteristics, and soft-tissue features of cardiac tumors, allowing accurate differentiation of benign and malignant lesions.

  2. The downside of downtime: The prevalence and work pacing consequences of idle time at work.

    Science.gov (United States)

    Brodsky, Andrew; Amabile, Teresa M

    2018-05-01

    Although both media commentary and academic research have focused much attention on the dilemma of employees being too busy, this paper presents evidence of the opposite phenomenon, in which employees do not have enough work to fill their time and are left with hours of meaningless idle time each week. We conducted six studies that examine the prevalence and work pacing consequences of involuntary idle time. In a nationally representative cross-occupational survey (Study 1), we found that idle time occurs frequently across all occupational categories; we estimate that employers in the United States pay roughly $100 billion in wages for time that employees spend idle. Studies 2a-3b experimentally demonstrate that there are also collateral consequences of idle time; when workers expect idle time following a task, their work pace declines and their task completion time increases. This decline reverses the well-documented deadline effect, producing a deadtime effect, whereby workers slow down as a task progresses. Our analyses of work pace patterns provide evidence for a time discounting mechanism: workers discount idle time when it is relatively distant, but act to avoid it increasingly as it becomes more proximate. Finally, Study 4 demonstrates that the expectation of being able to engage in leisure activities during posttask free time (e.g., surfing the Internet) can mitigate the collateral work pace losses due to idle time. Through examination and discussion of the effects of idle time at work, we broaden theory on work pacing. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  3. Failure of communication and capture: The perils of temporary unipolar pacing system

    Directory of Open Access Journals (Sweden)

    Efe Sahinoglu, BChE

    2015-06-01

    Full Text Available We present a case of a patient with pacemaker dependence secondary to complete heart block who developed loss of capture of her temporary pacemaker. Patient developed torsades de pointes then ventricular fibrillation, requiring CPR and external cardioversion. After patient was stabilized, it was noticed that loss of capture of pacemaker corresponded with nursing care, when the pulse generator was lifted off patient׳s chest wall, and that patient׳s temporary pacing system had been programmed to unipolar mode without knowledge of attending cardiologist. This case highlights the importance of communication ensuring all caregivers are aware of mode of the temporary pacing system.

  4. Impact of pacing on systemic ventricular function in L-transposition of the great arteries.

    Science.gov (United States)

    Hofferberth, Sophie C; Alexander, Mark E; Mah, Douglas Y; Bautista-Hernandez, Victor; del Nido, Pedro J; Fynn-Thompson, Francis

    2016-01-01

    To assess the impact of univentricular versus biventricular pacing (BiVP) on systemic ventricular function in patients with congenitally corrected transposition of the great arteries (ccTGA). We performed a retrospective review of all patients with a diagnosis of ccTGA who underwent pacemaker insertion. From 1993 to 2014, 53 patients were identified from the cardiology database and surgical records. Overall mortality was 7.5% (n = 4). One patient required transplantation and 3 late deaths occurred secondary to end-stage heart failure. Median follow-up was 3.7 years (range, 4 days to 22.5 years). Twenty-five (47%) underwent univentricular pacing only, of these, 8 (32%) developed significant systemic ventricular dysfunction. Twenty-eight (53%) received BiVP, 17 (26%) were upgraded from a dual-chamber system, 11 (21%) received primary BiVP. Fourteen (82%) of the 17 undergoing secondary BiVP demonstrated systemic ventricular dysfunction at the time of pacer upgrade, with 7 (50%) demonstrating improved systemic ventricular function after pacemaker upgrade. Overall, 42 (79%) patients underwent univentricular pacing, with 22 (52%) developing significant systemic ventricular dysfunction. In contrast, the 11 (21%) who received primary BiVP had preserved systemic ventricular function at latest follow-up. Late-onset systemic ventricular dysfunction is a major complication associated with the use of univentricular pacing in patients with ccTGA. All patients with ccTGA who develop heart block should undergo primary biventricular pacing, as this prevents late systemic ventricular dysfunction. Preemptive placement of BiVP leads at the time of anatomical repair or other permanent palliative procedure will facilitate subsequent BiVP should heart block develop. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  5. Cardiac gated ventilation

    International Nuclear Information System (INIS)

    Hanson, C.W. III; Hoffman, E.A.

    1995-01-01

    There are several theoretic advantages to synchronizing positive pressure breaths with the cardiac cycle, including the potential for improving distribution of pulmonary and myocardial blood flow and enhancing cardiac output. The authors evaluated the effects of synchronizing respiration to the cardiac cycle using a programmable ventilator and electron beam CT (EBCT) scanning. The hearts of anesthetized dogs were imaged during cardiac gated respiration with a 50 msec scan aperture. Multi slice, short axis, dynamic image data sets spanning the apex to base of the left ventricle were evaluated to determine the volume of the left ventricular chamber at end-diastole and end-systole during apnea, systolic and diastolic cardiac gating. The authors observed an increase in cardiac output of up to 30% with inspiration gated to the systolic phase of the cardiac cycle in a non-failing model of the heart

  6. Challenge of engaging all students via self-paced interactive electronic learning tutorials for introductory physics

    Directory of Open Access Journals (Sweden)

    Seth DeVore

    2017-05-01

    Full Text Available As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar introductory physics courses and then propose a framework for helping students engage effectively with the learning tools. The tutorials were developed via research in physics education and were found to be effective for a diverse group of introductory physics students in one-on-one implementation. Instructors encouraged the use of these tools in a self-paced learning environment by telling students that they would be helpful for solving the assigned homework problems and that the underlying physics principles in the tutorial problems would be similar to those in the in-class quizzes (which we call paired problems. We find that many students in the courses in which these interactive electronic learning tutorials were assigned as a self-study tool performed poorly on the paired problems. In contrast, a majority of student volunteers in one-on-one implementation greatly benefited from the tutorials and performed well on the paired problems. The significantly lower overall performance on paired problems administered as an in-class quiz compared to the performance of student volunteers who used the research-based tutorials in one-on-one implementation suggests that many students enrolled in introductory physics courses did not effectively engage with the tutorials outside of class and may have only used them superficially. The findings suggest that many students in need of out-of-class remediation via self-paced learning tools may have difficulty motivating themselves and may lack the self-regulation and time-management skills to engage effectively with tools specially designed to help them learn at their

  7. Challenge of engaging all students via self-paced interactive electronic learning tutorials for introductory physics

    Science.gov (United States)

    DeVore, Seth; Marshman, Emily; Singh, Chandralekha

    2017-06-01

    As research-based, self-paced electronic learning tools become increasingly available, a critical issue educators encounter is implementing strategies to ensure that all students engage with them as intended. Here, we first discuss the effectiveness of electronic learning tutorials as self-paced learning tools in large enrollment brick and mortar introductory physics courses and then propose a framework for helping students engage effectively with the learning tools. The tutorials were developed via research in physics education and were found to be effective for a diverse group of introductory physics students in one-on-one implementation. Instructors encouraged the use of these tools in a self-paced learning environment by telling students that they would be helpful for solving the assigned homework problems and that the underlying physics principles in the tutorial problems would be similar to those in the in-class quizzes (which we call paired problems). We find that many students in the courses in which these interactive electronic learning tutorials were assigned as a self-study tool performed poorly on the paired problems. In contrast, a majority of student volunteers in one-on-one implementation greatly benefited from the tutorials and performed well on the paired problems. The significantly lower overall performance on paired problems administered as an in-class quiz compared to the performance of student volunteers who used the research-based tutorials in one-on-one implementation suggests that many students enrolled in introductory physics courses did not effectively engage with the tutorials outside of class and may have only used them superficially. The findings suggest that many students in need of out-of-class remediation via self-paced learning tools may have difficulty motivating themselves and may lack the self-regulation and time-management skills to engage effectively with tools specially designed to help them learn at their own pace. We

  8. Reconstruction of the Terminal of an Abandoned Fractured Unipolar Coronary Sinus Lead: a Feasible Solution to Restore Effective Cardiac Resynchronization Therapy

    Directory of Open Access Journals (Sweden)

    Armando Gardini, MD

    2013-05-01

    Full Text Available Complications related to coronary sinus lead are not infrequent in recipients of cardiac resynchronization devices. We describe the case of a patient with a biventricular implantable cardioverter defibrillator with persistent phrenic nerve stimulation, previous coronary sinus lead fracture, and severe left subclavian vein stenosis. The reimplantation of a new coronary sinus lead on the left side, ipsilateral to the original implant, was unsuccessful. In order to avoid more complex and risky procedures, we performed the repair of the fractured abandoned lead with the reconstruction of the unipolar lead terminal. Effective biventricular pacing was obtained with satisfactory electrical parameters and it was maintained at twelve months follow-up.

  9. Introduction to Physics (Mechanics): A Semi-Self Paced Approach.

    Science.gov (United States)

    Schlenker, Richard M.

    Presented is a guide for an introductory college level physics course in mechanics. The course is contract graded and allows students to proceed at their own pace; however, lectures, problem solving sessions, and laboratory sessions are included. Students on an independent basis review video tapes, film loops, library study, and conduct an…

  10. Pacing Profiles in Competitive Track Races: Regulation of Exercise Intensity is related to Cognitive Ability

    Directory of Open Access Journals (Sweden)

    Debbie Van Biesen

    2016-12-01

    Full Text Available Pacing has been defined as the goal-directed regulation of exercise intensity over an exercise bout, in which athletes need to decide how and when to invest their energy. The purpose of this study was to explore if the regulation of exercise intensity during competitive track races is different between runners with and without intellectual impairment, which is characterized by significant limitations in intellectual functioning (IQ≤75 and adaptive behavioral deficits, diagnosed before the age of 18. The samples included elite runners with intellectual impairment (N= 36 and a comparison group of world class runners without impairment (N= 39, of which 47 were 400m runners (all male and 28 were 1500m-runners (15 male and 13 female. Pacing was analysed by means of 100m split times (for 400m races and 200m split times (for 1500m races. Based on the split times, the average velocity was calculated for four segments of the races. Velocity fluctuations were defined as the differences in velocity between consecutive race segments. A mixed model ANOVA revealed significant differences in pacing profiles between runners with and without intellectual impairment (p<.05. Maximal velocity of elite 400m runners with intellectual impairment in the first race segment (7.9 ± 0.3 m/s was well below the top-velocity reached by world level 400m runners without intellectual impairment (8.9 ±0.2 m/s, and their overall pace was slower (F=120.7, p<.05. In addition, both groups followed a different pacing profile and inter-individual differences in pacing profiles were larger, with differences most pronounced for 1500m races. Whereas male 1500m-runners without intellectual impairment reached a high velocity in the first 100m (7.2±0.1 m/s, slowly decelerated in the second race segment (-0.6±0.1 m/s, and finished with an end sprint (+0.9±0.1 m/s; the 1500m runners with intellectual impairment started slower (6.1±0.3 m/s, accelerated in the second segment (+ 0.2±0

  11. The effects of hypoxemia on myocardial blood flow during exercise.

    Science.gov (United States)

    Paridon, S M; Bricker, J T; Dreyer, W J; Reardon, M; Smith, E O; Porter, C B; Michael, L; Fisher, D J

    1989-03-01

    We evaluated the adequacy of regional and transmural blood flow during exercise and rapid pacing after 1 wk of hypoxemia. Seven mature mongrel dogs were made hypoxemic (mean O2 saturation = 72.4%) by anastomosis of left pulmonary artery to left atrial appendage. Catheters were placed in the left atrium, right atrium, pulmonary artery, and aorta. Atrial and ventricular pacing wires were placed. An aortic flow probe was placed to measure cardiac output. Ten nonshunted dogs, similarly instrumented, served as controls. Recovery time was approximately 1 wk. Cardiac output, mean aortic pressure, and oxygen saturation were measured at rest, with ventricular pacing, atrial pacing, and with treadmill exercise. Ventricular and atrial pace and exercise were at a heart rate of 200. Right ventricular free wall, left ventricular free wall, and septal blood flow were measured with radionuclide-labeled microspheres. Cardiac output, left atrial blood pressure, and aortic blood pressure were similar between the two groups of dogs in all testing states. Myocardial blood flow was significantly higher in the right and left ventricular free wall in the hypoxemic animals during resting and exercise testing states. Myocardial oxygen delivery was similar between the two groups of animals. Pacing resulted in an increase in myocardial blood flow in the control animals but not the hypoxemic animals.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Increased heart rate caused by atrial pacing with the closed-loop stimulation function prevented micturition syncope

    Directory of Open Access Journals (Sweden)

    Tatsuo Haraki, MD,PhD

    2013-10-01

    Full Text Available A 70-year-old man had been experiencing syncope several times a year. We implanted a DDD pacemaker with closed-loop stimulation (CLS function. When he urinated early in the morning, his increased atrial pacing rates elevated his heart rate (HR during and after micturition. After implantation of the DDD-CLS mode, he did not experience symptoms. In contrast, in the DDD-R mode, his intrinsic HR changed to atrial pacing after micturition but decreased to the basal rate within 2 min, and he experienced a sense of cold perspiration and presyncope. Increased HRs caused by atrial pacing with the CLS function were useful in the prevention of micturition syncope.

  13. Resuscitation outcomes comparing year 2000 with year 2005 ALS guidelines in a pig model of cardiac arrest.

    Science.gov (United States)

    Xanthos, Theodoros; Tsirikos-Karapanos, Nikolas; Papadimitriou, Dimitrios; Vlachos, Ioannis S; Tsiftsi, Katerina; Ekmektzoglou, Konstantinos A; Papadimitriou, Lila

    2007-06-01

    Ventricular fibrillation remains the leading cause of death in western societies. International organizations publish guidelines to follow in case of cardiac arrest. The aim of the present study is to assess whether the newly published guidelines record similar resuscitation success with the 2000 Advanced Life Support Guidelines on Resuscitation in a swine model of cardiac arrest. Nineteen landrace/large white pigs were used. Ventricular fibrillation was induced with the use of a transvenous pacing wire inserted into the right ventricle. The animals were randomized into two groups. In Group A, 10 animals were resuscitated using the 2000 guidelines, whereas in Group B, 9 animals were resuscitated using the 2005 guidelines. Both algorithms recorded similar successful resuscitation rates, as 60% of the animals in Group A and 44.5% in Group B were successfully resuscitated. However, animals in Group A restored a rhythm, compatible with a pulse, quicker than those in Group B (p=0.002). Coronary perfusion pressure (CPP) was not adversely affected by three defibrillation attempts in Group A. Both algorithms' resulted in comparable resuscitation success, however, guidelines 2000 resulted in faster resuscitation times. These preliminary results merit further investigation.

  14. Cardiac function and cognition in older community-dwelling cardiac patients.

    Science.gov (United States)

    Eggermont, Laura H P; Aly, Mohamed F A; Vuijk, Pieter J; de Boer, Karin; Kamp, Otto; van Rossum, Albert C; Scherder, Erik J A

    2017-11-01

    Cognitive deficits have been reported in older cardiac patients. An underlying mechanism for these findings may be reduced cardiac function. The relationship between cardiac function as represented by different echocardiographic measures and different cognitive function domains in older cardiac patients remains unknown. An older (≥70 years) heterogeneous group of 117 community-dwelling cardiac patients under medical supervision by a cardiologist underwent thorough echocardiographic assessment including left ventricular ejection fraction, cardiac index, left atrial volume index, left ventricular mass index, left ventricular diastolic function, and valvular calcification. During a home visit, a neuropsychological assessment was performed within 7.1 ± 3.8 months after echocardiographic assessment; the neuropsychological assessment included three subtests of a word-learning test (encoding, recall, recognition) to examine one memory function domain and three executive function tests, including digit span backwards, Trail Making Test B minus A, and the Stroop colour-word test. Regression analyses showed no significant linear or quadratic associations between any of the echocardiographic functions and the cognitive function measures. None of the echocardiographic measures as representative of cardiac function was correlated with memory or executive function in this group of community-dwelling older cardiac patients. These findings contrast with those of previous studies. © 2017 Japanese Psychogeriatric Society.

  15. A positron emission tomography study of self-paced finger movements at different frequencies

    International Nuclear Information System (INIS)

    Kawashima, R.; Inoue, K.; Sugiura, M.; Okada, K.; Ogawa, A.; Fukuda, H.

    1999-01-01

    Regional cerebral blood flow was measured in six right-handed volunteers using positron emission tomography during tasks involving repetitive self-paced finger tapping at five different frequencies. The contralateral primary sensorimotor cortex, the pre-supplementary motor area and the cingulate motor area showed significant activation during self-paced finger tapping tasks, compared with the resting state. A positive correlation between the regional cerebral blood flow and the movement frequency was found only in the primary sensorimotor cortex. In the pre-supplementary motor area and the cingulate motor area, however, activity increased when the subject employed movement frequencies faster or slower than his own pace. The same tendency was noted with respect to the relative variability of the inter-tapping interval.The results therefore indicate that the activity of the pre-supplementary motor area and the cingulate motor area may well be related to the increased difficulty in motor control rather than to the execution of the movement itself. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  16. Artificial skin and patient simulator comprising the artificial skin

    NARCIS (Netherlands)

    2011-01-01

    The invention relates to an artificial skin (10, 12, 14), and relates to a patient simulator (100) comprising the artificial skin. The artificial skin is a layered structure comprising a translucent cover layer (20) configured for imitating human or animal skin, and comprising a light emitting layer

  17. Cardiac function and cognition in older community-dwelling cardiac patients

    NARCIS (Netherlands)

    Eggermont, Laura H.P.; Aly, Mohamed F.A.; Vuijk, Pieter J.; de Boer, Karin; Kamp, Otto; van Rossum, Albert C.; Scherder, Erik J.A.

    2017-01-01

    Background: Cognitive deficits have been reported in older cardiac patients. An underlying mechanism for these findings may be reduced cardiac function. The relationship between cardiac function as represented by different echocardiographic measures and different cognitive function domains in older

  18. The Effects of Self-Paced Blended Learning of Mathematics

    Science.gov (United States)

    Balentyne, Phoebe; Varga, Mary Alice

    2016-01-01

    As online and blended learning gain more popularity in education, it becomes more important to understand their effects on student learning. The purpose of this study was to explore the effects of self-paced blended learning of mathematics on the attitudes and achievement of 26 high ability middle school students, and investigate the relationship…

  19. Similarities and Differences in Pacing Patterns in a 161-km and 101-km Ultra-Distance Road Race.

    Science.gov (United States)

    Tan, Philip L S; Tan, Frankie H Y; Bosch, Andrew N

    2016-08-01

    Tan, PLS, Tan, FHY, and Bosch, AN. Similarities and differences in pacing patterns in a 161-km and 101-km ultra-distance road race. J Strength Cond Res 30(8): 2145-2155, 2016-The purpose of this study was to establish and compare the pacing patterns of fast and slow finishers in a tropical ultra-marathon. Data were collected from the Craze Ultra-marathon held on the 22nd and 21st of September in 2012 and 2013, respectively. Finishers of the 161-km (N = 47) and 101-km (N = 120) categories of the race were divided into thirds (groups A-C) by merit of finishing time. Altogether, 17 and 11 split times were recorded for the 161-km and 101-km finishers, respectively, and used to calculate the mean running speed for each distance segment. Running speed for the first segment was normalized to 100, with all subsequent splits adjusted accordingly. Running speed during the last 5 km was calculated against the mean race pace to establish the existence of an end spurt. A reverse J-shaped pacing profile was demonstrated in all groups for both distance categories and only 38% of the finishers executed an end spurt. In the 101-km category, in comparison with groups B and C, group A maintained a significantly more even pace (p = 0.013 and 0.001, respectively) and completed the race at a significantly higher percent of initial starting speed (p = 0.001 and 0.001, respectively). Descriptive data also revealed that the top 5 finishers displayed a "herd-behavior" by staying close to the lead runner in the initial portion of the race. These findings demonstrate that to achieve a more even pace, recreational ultra-runners should adopt a patient sustainable starting speed, with less competitive runners setting realistic performance goals whereas competitive runners with a specific time goal to consider running in packs of similar pace.

  20. Centrifuge-Simulated Suborbital Spaceflight in a Subject with Cardiac Malformation.

    Science.gov (United States)

    Blue, Rebecca S; Blacher, Eric; Castleberry, Tarah L; Vanderploeg, James M

    2015-11-01

    Commercial spaceflight participants (SFPs) will introduce new medical challenges to the aerospace community, with unique medical conditions never before exposed to the space environment. This is a case report regarding the response of a subject with multiple cardiac malformations, including aortic insufficiency, pulmonary atresia, pulmonary valve replacement, ventricular septal defect (post-repair), and pulmonary artery stenosis (post-dilation), to centrifuge acceleration simulating suborbital flight. A 23-yr-old man with a history of multiple congenital cardiac malformations underwent seven centrifuge runs over 2 d. Day 1 consisted of two +G(z) runs (peak = +3.5 G(z), run 2) and two +G(x) runs (peak = +6.0 G(x), run 4). Day 2 consisted of three runs approximating suborbital spaceflight profiles (combined +G(x) and +G(z)). Data collected included blood pressure, electrocardiogram, pulse oximetry, neurovestibular exams, and post-run questionnaires regarding motion sickness, disorientation, greyout, and other symptoms. Despite the subject's significant medical history, he tolerated the acceleration profiles well and demonstrated no significant abnormal physiological responses. Potential risks to SFPs with aortic insufficiency, artificial heart valves, or valvular insufficiency include lower +G(z) tolerance, earlier symptom onset, and ineffective mitigation strategies such as anti-G straining maneuvers. There are no prior studies of prolonged accelerations approximating spaceflight in such individuals. This case demonstrates tolerance of acceleration profiles in an otherwise young and healthy individual with significant cardiac malformations, suggesting that such conditions may not necessarily preclude participation in commercial spaceflight.

  1. Artificial Intelligence.

    Science.gov (United States)

    Information Technology Quarterly, 1985

    1985-01-01

    This issue of "Information Technology Quarterly" is devoted to the theme of "Artificial Intelligence." It contains two major articles: (1) Artificial Intelligence and Law" (D. Peter O'Neill and George D. Wood); (2) "Artificial Intelligence: A Long and Winding Road" (John J. Simon, Jr.). In addition, it contains two sidebars: (1) "Calculating and…

  2. Artificial organs: recent progress in artificial hearing and vision.

    Science.gov (United States)

    Ifukube, Tohru

    2009-01-01

    Artificial sensory organs are a prosthetic means of sending visual or auditory information to the brain by electrical stimulation of the optic or auditory nerves to assist visually impaired or hearing-impaired people. However, clinical application of artificial sensory organs, except for cochlear implants, is still a trial-and-error process. This is because how and where the information transmitted to the brain is processed is still unknown, and also because changes in brain function (plasticity) remain unknown, even though brain plasticity plays an important role in meaningful interpretation of new sensory stimuli. This article discusses some basic unresolved issues and potential solutions in the development of artificial sensory organs such as cochlear implants, brainstem implants, artificial vision, and artificial retinas.

  3. Right heart failure due to loss of right ventricular capture in a patient with atrioventricular junction ablation and biventricular pacing.

    Science.gov (United States)

    Raffa, Santi; Fantoni, Cecilia; Restauri, Luigia; Auricchio, Angelo

    2005-10-01

    We describe the case of a patient with atrioventricular (AV) junction ablation and chronic biventricular pacing in which intermittent dysfunction of the right ventricular (RV) lead resulted in left ventricular (LV) stimulation alone and onset of severe right heart failure. Restoration of biventricular pacing by increasing device output and then performing lead revision resolved the issue. This case provides evidence that LV pacing alone in patients with AV junction ablation may lead to severe right heart failure, most likely as a result of iatrogenic mechanical dyssynchrony within the RV. Thus, probably this pacing mode should be avoided in pacemaker-dependent patients with heart failure.

  4. Study on incidence of pulmonary embolism in patients with cardiac pacemakers using lung perfusion mapping and ventilation scanning

    International Nuclear Information System (INIS)

    Yamashina, Hideki; Higo, Masanori; Sueda, Takashi

    1990-01-01

    We investigated pulmonary perfusion mapping and ventilation scanning employing 99mTC-MMA and 81mKr-Gas in patients with DDD and VVI cardiac pacemaker implantation. In 51 cases among 175 patients we observed some defects which matched the results from lung perfusion scanning in the pulmonary segments and sub-segments. These were diagnosed as pulmonary embolism after the possibility of other pulmonary diseases was rejected. The incidence rate of pulmonary embolism in patients with VVI (Ventricular pacing/sensing, inhibited type) pacemakers was 47 out of 138, or 34.1%, especially for those who received a pulmonary scanning examination whithin 6 months after pacemaker implantation. In contrast, those who were examined after 6 months had lower rates as well as chronological factors. The incidence rate of pulmonary embolism in 37 patients with DDD (Double chamber pacing/sensing, double modes of response) pacemakers was 10.8%, considerably lower than that for patients with VVI pacemakers. Therefore, one main factor of pulmonary embolism in patients with pacemakers could be the non-physiological phase of the contractions of both atria and ventricles. Other factors, such as the presence of foreign bodies in the endocardium, aging, and hypertension, could also promote pulmonary embolism. (author)

  5. [Infective endocarditis in intensive cardiac care unit - clinical and biochemical differences of blood-culture negative infective endocarditis].

    Science.gov (United States)

    Kaziród-Wolski, Karol; Sielski, Janusz; Ciuraszkiewicz, Katarzyna

    2017-01-23

    Diagnosis and treatment of infective endocarditis (IE) is still a challenge for physicians. Group of patients with the worst prognosis is treated in Intensive Cardiac Care Unit (ICCU). Etiologic agent can not be identified in a substantial number of patients. The aim of study is to find differences between patients with blood culture negative infective endocarditis (BCNIE) and blood culture positive infective endocarditis (BCPIE) treated in ICCU by comparing their clinical course and laboratory parameters. Retrospective analysis of 30 patients with IE hospitalized in ICCU Swietokrzyskie Cardiac Centre between 2010 and 2016. This group consist of 26 men (86,67%) and 4 women (13,3%). Mean age was 58 years ±13. Most of the cases were new disease, recurrence of the disease was observed in 2 cases (6,7%). 8 patients (26,7%) required artificial ventilation, 11 (36,7%) received inotropes and 6 (20%) vasopresors. In 14 (46,7%) cases blood cultures was negative (BCNIE), the rest of patients (16, 53,3%) was blood cultures - positive infective endocarditis (BCIE). Both of the groups were clinically similar. There were no statistically significant differences in incidence of cardiac implants, localization of bacterial vegetations, administered catecholamines, antibiotic therapy, artificial ventilation, surgical treatment, complication and in-hospital mortality. Incidence of cardiac complications in all of BCNIE cases and in 81,3% cases of BCPIE draws attention, but it is not statistically significant difference (p=0,08). There was statistically significant difference in mean BNP blood concentration (3005,17 ng/ml ±2045,2 vs 1013,42 ng/ml ±1087,6; p=0,01), but there were no statistically significant differences in rest of laboratory parameters. BCNIE group has got higher mean BNP blood concentration than BCPIE group. There were no statistically significant differences between these groups in others laboratory parameters, clinical course and administered antibiotic therapy

  6. Evaluation of Safety and Efficacy of Qinming8631 DR Implantable Cardiac Pacemaker in Chinese Patients: A Prospective, Multicenter, Randomized Controlled Trial of the First Domestically Developed Pacemaker of China.

    Science.gov (United States)

    Xiang, Mei-Xiang; Wang, Dong-Qi; Xu, Jing; Zhang, Zheng; Hu, Jian-Xin; Wang, Dong-Mei; Gu, Xiang; Liu, He-Ping; Guo, Tao; Yang, Xiang-Jun; Ling, Feng; Lin, Jia-Feng; Cai, Shang-Lang; Zhu, Guo-Bin; Wang, Jian-An

    2016-11-20

    High cost of imported pacemakers is a main obstacle for Chinese patients suffering from bradyarrhythmia, and a domestically developed pacemaker will help lower the burden. This study aimed to evaluate the safety and efficacy of Qinming8631 DR (Qinming Medical, Baoji, China), the first domestically developed dual-chamber pacemaker of China, compared with a commercially available pacemaker Talos DR (Biotronik, Berlin, Germany) in Chinese patients. A prospective randomized trial was conducted at 14 centers in China. Participants were randomized into trial (Qinming8631 DR) and control (Talos DR) groups. Parameters of the pacing systems were collected immediately after device implantation and during follow-ups. The effective pacing rate at 6-month follow-up was recorded as the primary end point. Electrical properties, magnet response, single- and double-pole polarity conversion, rate response function, and adverse events of the pacing system were analyzed. The Cochran-Mantel-Haenszel Chi-square test, paired t-test, and Wilcoxon signed-rank test were used for measuring primary qualitative outcomes and comparing normally and abnormally distributed measurement data. A total of 225 patients with a diagnosis of bradyarrhythmia and eligible for this study were randomly enrolled into the trial (n = 113) and control (n = 112) groups. They underwent successful pacemaker implantation with acceptable postoperative pacing threshold and sensitivity. Effective pacing rates of trial and control groups were comparable both in the full analysis set and the per protocol set (81.4% vs. 79.5%, P = 0.712 and 95.4% vs. 89.5%, P = 0.143, respectively). In both data sets, noninferiority of the trial group was above the predefined noninferiority limit(-9.5%). This study established the noninferiority of Qinming8631 DR to Talos DR. The safety and efficacy of Qinming8631 DR pacemaker were comparable to those of Talos DR in treating patients with cardiac bradyarrhythmia.

  7. Gait Coordination After Stroke: Benefits of Acoustically Paced Treadmill Walking

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.C.; Kwakkel, G.; van Wieringen, P.C.W.; Beek, P.J.

    2007-01-01

    Background and Purpose: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. Participants: Ten people after stroke volunteered for the

  8. Gait coordination after stroke: benefits of acoustically paced treadmill walking.

    NARCIS (Netherlands)

    Roerdink, M.; Lamoth, C.J.; Kwakkel, G.; Wieringen, P.C. van; Beek, P.J.

    2007-01-01

    BACKGROUND AND PURPOSE: Gait coordination often is compromised after stroke. The purpose of this study was to evaluate the efficacy of acoustically paced treadmill walking as a method for improving gait coordination in people after stroke. PARTICIPANTS: Ten people after stroke volunteered for the

  9. Environmental proxies of antigen exposure explain variation in immune investment better than indices of pace of life.

    Science.gov (United States)

    Horrocks, Nicholas P C; Hegemann, Arne; Ostrowski, Stéphane; Ndithia, Henry; Shobrak, Mohammed; Williams, Joseph B; Matson, Kevin D; Tieleman, B I

    2015-01-01

    Investment in immune defences is predicted to covary with a variety of ecologically and evolutionarily relevant axes, with pace of life and environmental antigen exposure being two examples. These axes may themselves covary directly or inversely, and such relationships can lead to conflicting predictions regarding immune investment. If pace of life shapes immune investment then, following life history theory, slow-living, arid zone and tropical species should invest more in immunity than fast-living temperate species. Alternatively, if antigen exposure drives immune investment, then species in antigen-rich tropical and temperate environments are predicted to exhibit higher immune indices than species from antigen-poor arid locations. To test these contrasting predictions we investigated how variation in pace of life and antigen exposure influence immune investment in related lark species (Alaudidae) with differing life histories and predicted risks of exposure to environmental microbes and parasites. We used clutch size and total number of eggs laid per year as indicators of pace of life, and aridity, and the climatic variables that influence aridity, as correlates of antigen abundance. We quantified immune investment by measuring four indices of innate immunity. Pace of life explained little of the variation in immune investment, and only one immune measure correlated significantly with pace of life, but not in the predicted direction. Conversely, aridity, our proxy for environmental antigen exposure, was predictive of immune investment, and larks in more mesic environments had higher immune indices than those living in arid, low-risk locations. Our study suggests that abiotic environmental variables with strong ties to environmental antigen exposure can be important correlates of immunological variation.

  10. Pacing, packing and sex-based differences in Olympic and IAAF World Championship marathons.

    Science.gov (United States)

    Hanley, Brian

    2016-09-01

    The aim of this study was to describe pacing profiles and packing behaviours of athletes in Olympic and World Championship marathons. Finishing and split times were collated for 673 men and 549 women across nine competitions. The mean speeds for each intermediate 5 km and end 2.2 km segments were calculated. Medallists of both sexes maintained even-paced running from 10 km onwards whereas slower finishers dropped off the lead pack at approximately half-distance. Athletes who ran with the same opponents throughout slowed the least in the second half (P tactics adopted and design training programmes accordingly.

  11. Antifibrillatory effects of renal denervation on ventricular fibrillation in a canine model of pacing-induced heart failure.

    Science.gov (United States)

    Luo, Qingzhi; Jin, Qi; Zhang, Ning; Huang, Shangwei; Han, Yanxin; Lin, Changjian; Ling, Tianyou; Chen, Kang; Pan, Wenqi; Wu, Liqun

    2018-01-01

    What is the central question of this study? In the present study, we investigated the effects of renal denervation on the vulnerability to ventricular fibrillation and the ventricular electrical properties in a rapid pacing-induced heart failure canine model. What is the main finding and its importance? Renal denervation significantly attenuated the process of heart failure and improved left ventricular systolic dysfunction, stabilized ventricular electrophysiological properties and decreased the vulnerability of the heart to ventricular fibrillation during heart failure. Thus, renal denervation can attenuate ventricular electrical remodelling and exert a potential antifibrillatory action in a pacing-induced heart failure canine model. In this study, we investigated the effects of renal denervation (RDN) on the vulnerability to ventricular fibrillation (VF) and the ventricular electrical properties in a canine model of pacing-induced heart failure (HF). Eighteen beagles were divided into the following three groups: control (n = 6), HF (n = 6) and HF+RDN (n = 6). Heart failure was induced by rapid right ventricular pacing. Renal denervation was performed simultaneously with the pacemaker implantation in the HF+RDN group. A 64-unipolar basket catheter was used to perform global endocardial mapping of the left ventricle. The restitution properties and dispersion of refractoriness were estimated from the activation recovery intervals (ARIs) by a pacing protocol. The VF threshold (VFT) was defined as the maximal pacing cycle length required to induce VF using a specific pacing protocol. The defibrillation threshold (DFT) was measured by an up-down algorithm. Renal denervation partly restored left ventricular systolic function and attenuated the process of HF. Compared with the control group, the VFT in the HF group was decreased by 27% (106 ± 8.0 versus 135 ± 10 ms, P Renal denervation significantly flattened the ventricular ARI restitution curve by 15% (1

  12. Transesophageal Doppler reliably tracks changes in cardiac output in comparison with intermittent pulmonary artery thermodilution in cardiac surgery patients

    DEFF Research Database (Denmark)

    Møller-Sørensen, Hasse; Cordtz, Joakim; Østergaard, Morten

    2017-01-01

    completed the study. Each patient were placed in the following successive positions: (1) supine, (2) head-down tilt, (3) head-up tilt, (4) supine, (5) supine with phenylephrine administration, (6) pace heart rate 80 beats per minute (bpm), (7) pace heart rate 110 bpm. The agreement of compared data...

  13. African experiences of humanitarian cardiovascular medicine: the Cardiac Centre of St. Elizabeth Catholic General Hospital, Shisong.

    Science.gov (United States)

    Budzee, Sr Appolonia; Tchoumi, Jc Tantchou; Giamberti, Alessandro; Ambassa, Jc; Cirri, Sylvia; Butera, Gianfranco

    2012-06-01

    The cardiac centre of Shisong inaugurated few years ago is a good example of the mobilization of humanitarian resources from the north and south for the improvement of cardiovascular diagnosis and treatment in Africa. From the inauguration of the Center to December 2011, 23 surgical missions have been organized, (5 peadiatric and 18 adults) and 204 patients have been operated with the help of the partners: Associazione Bambini Cardiopatici nel Mondo and Cuore Fratello. The Catheterisation Laboratory has performed a total of 117 diagnostic and interventional procedures while 22 pace makers were implanted (12 single-chambers and 10 dual-chambers). Many problems and challenges are faced everyday but with the enthusiasm, the dynamism and the professional skills of the personnel, the help of the partners we see a bright future.

  14. Effect of Music Tempo on Attentional Focus and Perceived Exertion during Self-selected Paced Walking

    OpenAIRE

    SILVA, ALDO COELHO; DOS SANTOS FERREIRA, SANDRO; ALVES, RAGAMI CHAVES; FOLLADOR, LUCIO; DA SILVA, SERGIO GREGORIO

    2016-01-01

    This study investigated the influence of music on the rating of perceived exertion (RPE) and attentional focus during walking at a self-selected pace. Fifteen overweight and obese women volunteered to participate in the study. They underwent four sessions: the first for incremental maximal test and anthropometric measurement followed by three experimental sessions. After the first session, they were exposed to three 30-minute walking sessions at a self-selected pace in a counterbalanced order...

  15. Hardware packet pacing using a DMA in a parallel computer

    Science.gov (United States)

    Chen, Dong; Heidelberger, Phillip; Vranas, Pavlos

    2013-08-13

    Method and system for hardware packet pacing using a direct memory access controller in a parallel computer which, in one aspect, keeps track of a total number of bytes put on the network as a result of a remote get operation, using a hardware token counter.

  16. The roles of the Q (q) wave in lead I and QRS frontal axis for diagnosing loss of left ventricular capture during cardiac resynchronization therapy.

    Science.gov (United States)

    Cao, Yuan-Yuan; Su, Yan-Gang; Bai, Jin; Wang, Wei; Wang, Jing-Feng; Qin, Sheng-Mei; Ge, Jun-Bo

    2015-01-01

    Loss of left ventricular (LV) capture may lead to deterioration of heart failure in patients with cardiac resynchronization therapy (CRT). Recognition of loss of LV capture in time is important in clinical practice. A total of 422 electrocardiograms were acquired and analyzed from 53 CRT patients at 8 different pacing settings (LV only, right ventricle [RV] only, biventricular [BV] pacing with LV preactivation of 60, 40, 20, and 0 milliseconds and RV preactivation of 20 and 40 milliseconds). A modified Ammann algorithm by adding a third step-presence of Q (q, or QS) wave-to the original 2-step Ammann algorithm and a QRS axis shift method were devised to identify the loss of LV capture. The accuracy of modified Ammann algorithm was significantly higher than that of Ammann algorithm (78.9% vs. 69.1%, P capture. The LV preactivation, or simultaneous BV activation and LV lead positioned in nonposterior or noninferior wall can increase the diagnostic power of the modified Ammann algorithm and QRS axis shift method. © 2014 Wiley Periodicals, Inc.

  17. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation.

    Science.gov (United States)

    Steven, Daniel; Reddy, Vivek Y; Inada, Keiichi; Roberts-Thomson, Kurt C; Seiler, Jens; Stevenson, William G; Michaud, Gregory F

    2010-03-01

    Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set. This pilot study investigated the relationship between loss of pace capture directly along the ablation line and electrogram criteria for PV isolation (PVI). Using a 3-dimensional anatomic mapping system and irrigated-tip radiofrequency (RF) ablation catheter, lesions were placed in the PV antra to encircle ipsilateral vein pairs until pace capture at 10 mA/2 ms no longer occurred along the line. During ablation, a circular mapping catheter was placed in an ipsilateral PV, but the electrograms were not revealed until loss-of-pace capture. The procedural end point was PVI (entrance and exit block). Thirty patients (57 +/- 12 years; 15 male [50%]) undergoing PVI in 2 centers (3 primary operators) were included (left atrial diameter 40 +/- 4 mm, left ventricular ejection fraction 60 +/- 7%). All patients reached the end points of complete PVI and loss of pace capture. When PV electrograms were revealed after loss of pace capture along the line, PVI was present in 57 of 60 (95%) vein pairs. In the remaining 3 of 60 (5%) PV pairs, further RF applications achieved PVI. The procedure duration was 237 +/- 46 minutes, with a fluoroscopy time of 23 +/- 9 minutes. Analysis of the blinded PV electrograms revealed that even after PVI was achieved, additional sites of pace capture were present on the ablation line in 30 of 60 (50%) of the PV pairs; 10 +/- 4 additional RF lesions were necessary to fully achieve loss of pace capture. After ablation, the electrogram amplitude was lower at unexcitable sites (0.25 +/- 0.15 mV vs. 0.42 +/- 0.32 mV, P capture sites, suggesting that electrogram amplitude lacks specificity for identifying pace capture sites. Complete loss of pace capture directly along the circumferential

  18. The Self-Paced Graz Brain-Computer Interface: Methods and Applications

    Directory of Open Access Journals (Sweden)

    Reinhold Scherer

    2007-01-01

    Full Text Available We present the self-paced 3-class Graz brain-computer interface (BCI which is based on the detection of sensorimotor electroencephalogram (EEG rhythms induced by motor imagery. Self-paced operation means that the BCI is able to determine whether the ongoing brain activity is intended as control signal (intentional control or not (non-control state. The presented system is able to automatically reduce electrooculogram (EOG artifacts, to detect electromyographic (EMG activity, and uses only three bipolar EEG channels. Two applications are presented: the freeSpace virtual environment (VE and the Brainloop interface. The freeSpace is a computer-game-like application where subjects have to navigate through the environment and collect coins by autonomously selecting navigation commands. Three subjects participated in these feedback experiments and each learned to navigate through the VE and collect coins. Two out of the three succeeded in collecting all three coins. The Brainloop interface provides an interface between the Graz-BCI and Google Earth.

  19. Acquired tricuspid valve stenosis due to intentionally redundant transvenous lead placement for VDD pacing in two small dogs.

    Science.gov (United States)

    Gunther-Harrington, Catherine T; Michel, Adam O; Stern, Joshua A

    2015-12-01

    Placement of an endocardial VDD pacing lead in small dogs (stenosis in two small dogs between 8 months and 4 years after VDD pacemaker placement for third-degree atrioventricular block. Echocardiography and Doppler echocardiography identified elevated transtricuspid flow velocities, prolonged pressure half-times, decreased valve leaflet excursions, and tricuspid regurgitation in both cases. Both cases were euthanized secondary to this pacing complication. Necropsy was performed in one case and confirmed adherence between the redundant lead loop, atrial and valve tissue. While VDD pacing in dogs has proven hemodynamic benefits, these benefits have not been demonstrated in terms of survival benefit or clinical signs. The requirement of redundant lead placement in small dogs for appropriate VDD lead function creates potential deleterious effects that should be weighed against the possible clinical value of VDD pacing in these patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. 'Cardiogenic vertigo'--true vertigo as the presenting manifestation of primary cardiac disease.

    Science.gov (United States)

    Newman-Toker, David E; Camargo, Carlos A

    2006-03-01

    A 90-year-old woman presented to a hospital emergency department with a brief loss of consciousness that was heralded by spinning vertigo lasting approximately 2 min. She had a long history of intermittent brief episodes of rotatory vertigo, presyncope, and non-vertiginous dizziness, occurring either with or without loss of consciousness. Although initially attributed to symptomatic carotid artery stenosis, these episodes persisted, despite surgical restoration of carotid artery blood flow 1 year after her first syncope. Her medical history was otherwise notable for hypertension, mild depression and a gradual decline in gait and balance function attributed to left hip arthritis and older age. Bedside history and examination, non-contrast head CT scan, electrocardiogram, transthoracic echocardiogram, and bedside cardiac telemetry. Sick sinus syndrome or severe reflex bradycardia with asystole causing recurrent, episodic vertigo, presyncope, non-vertiginous dizziness and syncope (Stokes-Adams attacks). Placement of a temporary pacing wire, followed by surgical implantation of a single-chamber ventricular (VVI) pacemaker.

  1. Two-photon induced collagen cross-linking in bioartificial cardiac tissue

    Science.gov (United States)

    Kuetemeyer, Kai; Kensah, George; Heidrich, Marko; Meyer, Heiko; Martin, Ulrich; Gruh, Ina; Heisterkamp, Alexander

    2011-08-01

    Cardiac tissue engineering is a promising strategy for regenerative therapies to overcome the shortage of donor organs for transplantation. Besides contractile function, the stiffness of tissue engineered constructs is crucial to generate transplantable tissue surrogates with sufficient mechanical stability to withstand the high pressure present in the heart. Although several collagen cross-linking techniques have proven to be efficient in stabilizing biomaterials, they cannot be applied to cardiac tissue engineering, as cell death occurs in the treated area. Here, we present a novel method using femtosecond (fs) laser pulses to increase the stiffness of collagen-based tissue constructs without impairing cell viability. Raster scanning of the fs laser beam over riboflavin-treated tissue induced collagen cross-linking by two-photon photosensitized singlet oxygen production. One day post-irradiation, stress-strain measurements revealed increased tissue stiffness by around 40% being dependent on the fibroblast content in the tissue. At the same time, cells remained viable and fully functional as demonstrated by fluorescence imaging of cardiomyocyte mitochondrial activity and preservation of active contraction force. Our results indicate that two-photon induced collagen cross-linking has great potential for studying and improving artificially engineered tissue for regenerative therapies.

  2. Planning the Marketing Strategy. PACE Revised. Level 1. Unit 6. Research & Development Series No. 240AB6.

    Science.gov (United States)

    Ashmore, M. Catherine; Pritz, Sandra G.

    This lesson on planning a marketing strategy, the sixth in a series of 18 units, is part of the first level of a comprehensive entrepreneurship curriculum entitled: A Program for Acquiring Competence in Entrepreneurship (PACE). (Designed for use with secondary students, the first level of PACE introduces students to the concepts involved in…

  3. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  4. Radiotherapy-Induced Cardiac Implantable Electronic Device Dysfunction in Patients With Cancer.

    Science.gov (United States)

    Bagur, Rodrigo; Chamula, Mathilde; Brouillard, Émilie; Lavoie, Caroline; Nombela-Franco, Luis; Julien, Anne-Sophie; Archambault, Louis; Varfalvy, Nicolas; Gaudreault, Valérie; Joncas, Sébastien X; Israeli, Zeev; Parviz, Yasir; Mamas, Mamas A; Lavi, Shahar

    2017-01-15

    Radiotherapy can affect the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or damage. We sought to assess the incidence, predictors, and clinical impact of CIED dysfunction (CIED-D) after radiotherapy for cancer treatment. Clinical characteristics, cancer, different types of CIEDs, and radiation dose were evaluated. The investigation identified 230 patients, mean age 78 ± 8 years and 70% were men. A total of 199 patients had pacemakers (59% dual chamber), 21 (9%) cardioverter-defibrillators, and 10 (4%) resynchronizators or defibrillators. The left pectoral (n = 192, 83%) was the most common CIED location. Sixteen patients (7%) experienced 18 events of CIED-D after radiotherapy. Reset to backup pacing mode was the most common encountered dysfunction, and only 1 (6%) patient of those with CIED-D experienced symptoms of atrioventricular dyssynchrony. Those who had CIED-D tended to have a shorter device age at the time of radiotherapy compared to those who did not (2.5 ± 1.5 vs 3.8 ± 3.4 years, p = 0.09). The total dose prescribed to the tumor was significantly greater among those who had CIED-D (66 ± 30 vs 42 ± 23 Gy, p radiotherapy for cancer treatment, the occurrence of newly diagnosed CIED-D was 7%, and the reset to backup pacing mode was the most common encountered dysfunction. The total dose prescribed to the tumor was a predictor of CIED-D. Importantly, although the unpredictability of CIEDs under radiotherapy is still an issue, none of our patients experienced significant symptoms, life-threatening arrhythmias, or conduction disorders. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Cardiac Function Remains Impaired Despite Reversible Cardiac Remodeling after Acute Experimental Viral Myocarditis

    Directory of Open Access Journals (Sweden)

    Peter Moritz Becher

    2017-01-01

    Full Text Available Background. Infection with Coxsackievirus B3 induces myocarditis. We aimed to compare the acute and chronic phases of viral myocarditis to identify the immediate effects of cardiac inflammation as well as the long-term effects after resolved inflammation on cardiac fibrosis and consequently on cardiac function. Material and Methods. We infected C57BL/6J mice with Coxsackievirus B3 and determined the hemodynamic function 7 as well as 28 days after infection. Subsequently, we analyzed viral burden and viral replication in the cardiac tissue as well as the expression of cytokines and matrix proteins. Furthermore, cardiac fibroblasts were infected with virus to investigate if viral infection alone induces profibrotic signaling. Results. Severe cardiac inflammation was determined and cardiac fibrosis was consistently colocalized with inflammation during the acute phase of myocarditis. Declined cardiac inflammation but no significantly improved hemodynamic function was observed 28 days after infection. Interestingly, cardiac fibrosis declined to basal levels as well. Both cardiac inflammation and fibrosis were reversible, whereas the hemodynamic function remains impaired after healed viral myocarditis in C57BL/6J mice.

  6. Current role of cardiac and extra-cardiac pathologies in clinically indicated cardiac computed tomography with emphasis on status before pulmonary vein isolation

    Energy Technology Data Exchange (ETDEWEB)

    Sohns, J.M.; Lotz, J. [Goettingen University Medical Center (Germany). Inst. for Diagnostic and Interventional Radiology; German Center for Cardiovascular Research (DZHK), Goettingen (Germany); Menke, J.; Staab, W.; Fasshauer, M.; Kowallick, J.T.; Zwaka, P.A.; Schwarz, A. [Goettingen University Medical Center (Germany). Inst. for Diagnostic and Interventional Radiology; Spiro, J. [Koeln University Hospital (Germany). Radiology; Bergau, L.; Unterberg-Buchwald, C. [Goettingen University Medical Center (Germany). Cardiology and Pneumology

    2014-09-15

    Purpose: The aim of this study was to assess the incidence of cardiac and significant extra-cardiac findings in clinical computed tomography of the heart in patients with atrial fibrillation before pulmonary vein isolation (PVI). Materials and Methods: 224 patients (64 ± 10 years; male 63%) with atrial fibrillation were examined by cardiac 64-slice multidetector CT before PVI. Extra-cardiac findings were classified as 'significant' if they were recommended to additional diagnostics or therapy, and otherwise as 'non-significant'. Additionally, cardiac findings were documented in detail. Results: A total of 724 cardiac findings were identified in 203 patients (91% of patients). Additionally, a total of 619 extra-cardiac findings were identified in 179 patients (80% of patients). Among these extra-cardiac findings 196 (32%) were 'significant', and 423 (68%) were 'non-significant'. In 2 patients (1%) a previously unknown malignancy was detected (esophageal cancer and lung cancer, local stage, no metastasis). 203 additional imaging diagnostics followed to clarify the 'significant' findings (124 additional CT, costs 38,314.69 US dollars). Overall, there were 3.2 cardiac and 2.8 extra-cardiac findings per patient. Extra-cardiac findings appear significantly more frequently in patients over 60 years old, in smokers and in patients with a history of cardiac findings (p < 0.05). Conclusion: Cardiac CT scans before PVI should be screened for extracardiac incidental findings that could have important clinical implications for each patient. (orig.)

  7. Pacing and decision making in sport and exercise: the roles of perception and action in the regulation of exercise intensity.

    Science.gov (United States)

    Smits, Benjamin L M; Pepping, Gert-Jan; Hettinga, Florentina J

    2014-06-01

    In pursuit of optimal performance, athletes and physical exercisers alike have to make decisions about how and when to invest their energy. The process of pacing has been associated with the goal-directed regulation of exercise intensity across an exercise bout. The current review explores divergent views on understanding underlying mechanisms of decision making in pacing. Current pacing literature provides a wide range of aspects that might be involved in the determination of an athlete's pacing strategy, but lacks in explaining how perception and action are coupled in establishing behaviour. In contrast, decision-making literature rooted in the understanding that perception and action are coupled provides refreshing perspectives on explaining the mechanisms that underlie natural interactive behaviour. Contrary to the assumption of behaviour that is managed by a higher-order governor that passively constructs internal representations of the world, an ecological approach is considered. According to this approach, knowledge is rooted in the direct experience of meaningful environmental objects and events in individual environmental processes. To assist a neuropsychological explanation of decision making in exercise regulation, the relevance of the affordance competition hypothesis is explored. By considering pacing as a behavioural expression of continuous decision making, new insights on underlying mechanisms in pacing and optimal performance can be developed.

  8. Effect of Psychological Intervention on Marital Satisfaction of Mothers with Slow Pace Under 5 Years Children

    Directory of Open Access Journals (Sweden)

    Mehran Soleymani

    2012-04-01

    Full Text Available Objectives: Objective of this study was investigating impact of early psychological interventions on marital satisfaction of mothers with slow pace under 5 years children. Considering variables of the research, that is, early psychological interventions and marital satisfaction, research hypotheses was as follows: "early psychological interventions affect marital satisfaction of mothers with slow pace under 5 years children" and it was examined. Methods: This research is of experimental type and pretest-posttest plan with control groups was used. Statistical population included all mothers with slow pace under 5 years children in Urmia. To this end, 40 mothers with slow pace children were selected as the sample in a non-random manner by convenience sampling. They were assigned randomly into two groups of 20 (20 test group and 20 control group, and finally psychological interventions were conducted on one of groups randomly. In order to evaluate marital satisfaction, Enrich marital satisfaction questionnaire with 47 items was used. Data were analyzed by univariate analysis of covariance. Results: findings showed that there is significant difference between two groups in posttest in overall score of marital satisfaction as well as in some elements such as conventional responses, marital satisfaction, personality issues, marital relationships, conflict resolution, leisure, parenting, family and friends, and ideological orientation and sexual relations (P<0.005, and no significant difference was observed in financial supervision and roles related to gender equality. Discusion: Psychological interventions were effective in promoting marital satisfaction in mothers with slow pace under 5 years children.

  9. Effect of recovery interventions on cycling performance and pacing strategy in the heat.

    Science.gov (United States)

    De Pauw, Kevin; Roelands, Bart; Vanparijs, Jef; Meeusen, Romain

    2014-03-01

    To determine the effect of active recovery (AR), passive rest (PR), and cold-water immersion (CWI) after 90 min of intensive cycling on a subsequent 12-min time trial (TT2) and the applied pacing strategy in TT2. After a maximal test and familiarization trial, 9 trained male subjects (age 22 ± 3 y, VO2max 62.1 ± 5.3 mL · min-1 · kg-1) performed 3 experimental trials in the heat (30°C). Each trial consisted of 2 exercise tasks separated by 1 h. The first was a 60-min constant-load trial at 55% of the maximal power output followed by a 30-min time trial (TT1). The second comprised a 12-min simulated time trial (TT2). After TT1, AR, PR, or CWI was applied for 15 min. No significant TT2 performance differences were observed, but a 1-sample t test (within each condition) revealed different pacing strategies during TT2. CWI resulted in an even pacing strategy, while AR and PR resulted in a gradual decline of power output after the onset of TT2 (P ≤ .046). During recovery, AR and CWI showed a trend toward faster blood lactate ([BLa]) removal, but during TT2 significantly higher [BLa] was only observed after CWI compared with PR (P = .011). The pacing strategy during subsequent cycling performance in the heat is influenced by the application of different postexercise recovery interventions. Although power was not significantly altered between groups, CWI enabled a differently shaped power profile, likely due to decreased thermal strain.

  10. Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management.

    Science.gov (United States)

    Baruteau, Alban-Elouen; Pass, Robert H; Thambo, Jean-Benoit; Behaghel, Albin; Le Pennec, Solène; Perdreau, Elodie; Combes, Nicolas; Liberman, Leonardo; McLeod, Christopher J

    2016-09-01

    Atrioventricular block is classified as congenital if diagnosed in utero, at birth, or within the first month of life. The pathophysiological process is believed to be due to immune-mediated injury of the conduction system, which occurs as a result of transplacental passage of maternal anti-SSA/Ro-SSB/La antibodies. Childhood atrioventricular block is therefore diagnosed between the first month and the 18th year of life. Genetic variants in multiple genes have been described to date in the pathogenesis of inherited progressive cardiac conduction disorders. Indications and techniques of cardiac pacing have also evolved to allow safe permanent cardiac pacing in almost all patients, including those with structural heart abnormalities. Early diagnosis and appropriate management are critical in many cases in order to prevent sudden death, and this review critically assesses our current understanding of the pathogenetic mechanisms, clinical course, and optimal management of congenital and childhood AV block. • Prevalence of congenital heart block of 1 per 15,000 to 20,000 live births. AV block is defined as congenital if diagnosed in utero, at birth, or within the first month of life, whereas childhood AV block is diagnosed between the first month and the 18th year of life. As a result of several different etiologies, congenital and childhood atrioventricular block may occur in an entirely structurally normal heart or in association with concomitant congenital heart disease. Cardiac pacing is indicated in symptomatic patients and has several prophylactic indications in asymptomatic patients to prevent sudden death. • Autoimmune, congenital AV block is associated with a high neonatal mortality rate and development of dilated cardiomyopathy in 5 to 30 % cases. What is New: • Several genes including SCN5A have been implicated in autosomal dominant forms of familial progressive cardiac conduction disorders. • Leadless pacemaker technology and gene therapy for

  11. Computerized method for evaluating diagnostic image quality of calcified plaque images in cardiac CT: Validation on a physical dynamic cardiac phantom

    Energy Technology Data Exchange (ETDEWEB)

    King, Martin; Rodgers, Zachary; Giger, Maryellen L.; Bardo, Dianna M. E.; Patel, Amit R. [Department of Radiology, Committee on Medical Physics, University of Chicago, 5841 South Maryland Avenue, MC 2026, Chicago, Illinois 60637 (United States); Department of Diagnostic Radiology, Oregon Health and Science University, 3181 Southwest Sam Jackson Park Road, Portland, Oregon 97239 (United States); Department of Medicine, University of Chicago, 5841 South Maryland Avenue, MC 5084, Chicago, Illinois 60637 (United States)

    2010-11-15

    Purpose: In cardiac computed tomography (CT), important clinical indices, such as the coronary calcium score and the percentage of coronary artery stenosis, are often adversely affected by motion artifacts. As a result, the expert observer must decide whether or not to use these indices during image interpretation. Computerized methods potentially can be used to assist in these decisions. In a previous study, an artificial neural network (ANN) regression model provided assessability (image quality) indices of calcified plaque images from the software NCAT phantom that were highly agreeable with those provided by expert observers. The method predicted assessability indices based on computer-extracted features of the plaque. In the current study, the ANN-predicted assessability indices were used to identify calcified plaque images with diagnostic calcium scores (based on mass) from a physical dynamic cardiac phantom. The basic assumption was that better quality images were associated with more accurate calcium scores. Methods: A 64-channel CT scanner was used to obtain 500 calcified plaque images from a physical dynamic cardiac phantom at different heart rates, cardiac phases, and plaque locations. Two expert observers independently provided separate sets of assessability indices for each of these images. Separate sets of ANN-predicted assessability indices tailored to each observer were then generated within the framework of a bootstrap resampling scheme. For each resampling iteration, the absolute calcium score error between the calcium scores of the motion-contaminated plaque image and its corresponding stationary image served as the ground truth in terms of indicating images with diagnostic calcium scores. The performances of the ANN-predicted and observer-assigned indices in identifying images with diagnostic calcium scores were then evaluated using ROC analysis. Results: Assessability indices provided by the first observer and the corresponding ANN performed

  12. Running pace decrease during a marathon is positively related to blood markers of muscle damage.

    Directory of Open Access Journals (Sweden)

    Juan Del Coso

    Full Text Available BACKGROUND: Completing a marathon is one of the most challenging sports activities, yet the source of running fatigue during this event is not completely understood. The aim of this investigation was to determine the cause(s of running fatigue during a marathon in warm weather. METHODOLOGY/PRINCIPAL FINDINGS: We recruited 40 amateur runners (34 men and 6 women for the study. Before the race, body core temperature, body mass, leg muscle power output during a countermovement jump, and blood samples were obtained. During the marathon (27 °C; 27% relative humidity running fatigue was measured as the pace reduction from the first 5-km to the end of the race. Within 3 min after the marathon, the same pre-exercise variables were obtained. RESULTS: Marathoners reduced their running pace from 3.5 ± 0.4 m/s after 5-km to 2.9 ± 0.6 m/s at the end of the race (P 15% pace reduction had elevated post-race myoglobin (1318 ± 1411 v 623 ± 391 µg L(-1; P<0.05, lactate dehydrogenase (687 ± 151 v 583 ± 117 U L(-1; P<0.05, and creatine kinase (564 ± 469 v 363 ± 158 U L(-1; P = 0.07 in comparison with marathoners that preserved their running pace reasonably well throughout the race. However, they did not differ in their body mass change (-3.1 ± 1.0 v -3.0 ± 1.0%; P = 0.60 or post-race body temperature (38.7 ± 0.7 v 38.9 ± 0.9 °C; P = 0.35. CONCLUSIONS/SIGNIFICANCE: Running pace decline during a marathon was positively related with muscle breakdown blood markers. To elucidate if muscle damage during a marathon is related to mechanistic or metabolic factors requires further investigation.

  13. DiPALS: Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis - a randomised controlled trial.

    Science.gov (United States)

    McDermott, Christopher J; Bradburn, Mike J; Maguire, Chin; Cooper, Cindy L; Baird, Wendy O; Baxter, Susan K; Cohen, Judith; Cantrill, Hannah; Dixon, Simon; Ackroyd, Roger; Baudouin, Simon; Bentley, Andrew; Berrisford, Richard; Bianchi, Stephen; Bourke, Stephen C; Darlison, Roy; Ealing, John; Elliott, Mark; Fitzgerald, Patrick; Galloway, Simon; Hamdalla, Hisham; Hanemann, C Oliver; Hughes, Philip; Imam, Ibrahim; Karat, Dayalan; Leek, Roger; Maynard, Nick; Orrell, Richard W; Sarela, Abeezar; Stradling, John; Talbot, Kevin; Taylor, Lyn; Turner, Martin; Simonds, Anita K; Williams, Tim; Wedzicha, Wisia; Young, Carolyn; Shaw, Pamela J

    2016-06-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disease resulting in death, usually from respiratory failure, within 2-3 years of symptom onset. Non-invasive ventilation (NIV) is a treatment that when given to patients in respiratory failure leads to improved survival and quality of life. Diaphragm pacing (DP), using the NeuRx/4(®) diaphragm pacing system (DPS)™ (Synapse Biomedical, Oberlin, OH, USA), is a new technique that may offer additional or alternative benefits to patients with ALS who are in respiratory failure. The Diaphragm Pacing in patients with Amyotrophic Lateral Sclerosis (DiPALS) trial evaluated the effect of DP on survival over the study duration in patients with ALS with respiratory failure. The DiPALS trial was a multicentre, parallel-group, open-label, randomised controlled trial incorporating health economic analyses and a qualitative longitudinal substudy. Eligible participants had a diagnosis of ALS (ALS laboratory-supported probable, clinically probable or clinically definite according to the World Federation of Neurology revised El Escorial criteria), had been stabilised on riluzole for 30 days, were aged ≥ 18 years and were in respiratory failure. We planned to recruit 108 patients from seven UK-based specialist ALS or respiratory centres. Allocation was performed using 1 : 1 non-deterministic minimisation. Participants were randomised to either standard care (NIV alone) or standard care (NIV) plus DP using the NeuRX/4 DPS. The primary outcome was overall survival, defined as the time from randomisation to death from any cause. Secondary outcomes were patient quality of life [assessed by European Quality of Life-5 Dimensions, three levels (EQ-5D-3L), Short Form questionnaire-36 items and Sleep Apnoea Quality of Life Index questionnaire]; carer quality of life (EQ-5D-3L and Caregiver Burden Inventory); cost-utility analysis and health-care resource use; tolerability and adverse events. Acceptability and attitudes to

  14. Epidemiology and Outcomes After In-Hospital Cardiac Arrest After Pediatric Cardiac Surgery

    Science.gov (United States)

    Gupta, Punkaj; Jacobs, Jeffrey P.; Pasquali, Sara K.; Hill, Kevin D.; Gaynor, J. William; O’Brien, Sean M.; He, Max; Sheng, Shubin; Schexnayder, Stephen M.; Berg, Robert A.; Nadkarni, Vinay M.; Imamura, Michiaki; Jacobs, Marshall L.

    2014-01-01

    Background Multicenter data regarding cardiac arrest in children undergoing heart operations are limited. We describe epidemiology and outcomes associated with postoperative cardiac arrest in a large multiinstitutional cohort. Methods Patients younger than 18 years in the Society of Thoracic Surgeons Congenital Heart Surgery Database (2007 through 2012) were included. Patient factors, operative characteristics, and outcomes were described for patients with and without postoperative cardiac arrest. Multivariable models were used to evaluate the association of center volume with cardiac arrest rate and mortality after cardiac arrest, adjusting for patient and procedural factors. Results Of 70,270 patients (97 centers), 1,843 (2.6%) had postoperative cardiac arrest. Younger age, lower weight, and presence of preoperative morbidities (all p < 0.0001) were associated with cardiac arrest. Arrest rate increased with procedural complexity across common benchmark operations, ranging from 0.7% (ventricular septal defect repair) to 12.7% (Norwood operation). Cardiac arrest was associated with significant mortality risk across procedures, ranging from 15.4% to 62.3% (all p < 0.0001). In multivariable analysis, arrest rate was not associated with center volume (odds ratio, 1.06; 95% confidence interval, 0.71 to 1.57 in low- versus high-volume centers). However, mortality after cardiac arrest was higher in low-volume centers (odds ratio, 2.00; 95% confidence interval, 1.52 to 2.63). This association was present for both high- and low-complexity operations. Conclusions Cardiac arrest carries a significant mortality risk across the stratum of procedural complexity. Although arrest rates are not associated with center volume, lower-volume centers have increased mortality after cardiac arrest. Further study of mechanisms to prevent cardiac arrest and to reduce mortality in those with an arrest is warranted. PMID:25443018

  15. A hybrid NIRS-EEG system for self-paced brain computer interface with online motor imagery.

    Science.gov (United States)

    Koo, Bonkon; Lee, Hwan-Gon; Nam, Yunjun; Kang, Hyohyeong; Koh, Chin Su; Shin, Hyung-Cheul; Choi, Seungjin

    2015-04-15

    For a self-paced motor imagery based brain-computer interface (BCI), the system should be able to recognize the occurrence of a motor imagery, as well as the type of the motor imagery. However, because of the difficulty of detecting the occurrence of a motor imagery, general motor imagery based BCI studies have been focusing on the cued motor imagery paradigm. In this paper, we present a novel hybrid BCI system that uses near infrared spectroscopy (NIRS) and electroencephalography (EEG) systems together to achieve online self-paced motor imagery based BCI. We designed a unique sensor frame that records NIRS and EEG simultaneously for the realization of our system. Based on this hybrid system, we proposed a novel analysis method that detects the occurrence of a motor imagery with the NIRS system, and classifies its type with the EEG system. An online experiment demonstrated that our hybrid system had a true positive rate of about 88%, a false positive rate of 7% with an average response time of 10.36 s. As far as we know, there is no report that explored hemodynamic brain switch for self-paced motor imagery based BCI with hybrid EEG and NIRS system. From our experimental results, our hybrid system showed enough reliability for using in a practical self-paced motor imagery based BCI. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Electrophysiology Catheter-Facilitated coronary sinus cannulation and implantation of cardiac resynchronization therapy systems

    Directory of Open Access Journals (Sweden)

    Antonis S. Manolis, MD, FESC, FACC, FHRS

    2018-01-01

    Full Text Available Background: Cardiac resynchronization therapy (CRT device implantation is hampered by difficult placement of the left ventricular (LV lead. We have routinely used a steerable electrophysiology catheter to guide coronary sinus (CS cannulation and facilitate LV lead positioning. The aim of this prospective study is to present our results with this approach in 138 consecutive patients receiving a CRT device over 10 years. Methods: The study included 120 men and 18 women, aged 64.8±11.4 years, with coronary disease (n=63, cardiomyopathy (n=72, or other disease (n=3, and mean ejection fraction of 24.5±4.5%. Devices were implanted for refractory heart failure and dyssynchrony, all but 2 in the presence of left bundle branch block. Implanted devices included biventricular pacemakers (CRT-P (n=33 and cardioverter defibrillators (CRT-D (n=105. Results: Using the electrophysiology catheter, the CS could be engaged in 134 (97.1% patients. In 4 patients failing CS cannulation, a dual-chamber device was implanted in 2, and bifocal right ventricular pacing was effected in 2. Bifocal (n=2 or conventional (n=1 systems were implanted in another 3 patients, in whom the LV lead got dislodged (n=2 or removed because of local dissection (n=1. Thus, finally, a CRT system was successfully established in 131 (94.9% patients. There were 3 patients with CS dissection, of whom 1 was complicated by cardiac tamponade managed with pericardiocentesis. There were no perioperative deaths. During follow-up (31.0±21.2 months, clinical improvement was reported by 108 (82.4% patients. Conclusion: Routine use of an electrophysiology catheter greatly facilitated CS cannulation and successful LV lead placement in ∼95% of patients undergoing CRT system implantation. Keywords: heart failure, cardiac resynchronization therapy, implantable cardioverter defibrillator, coronary sinus, left ventricular lead

  17. Stimulating endogenous cardiac regeneration

    Directory of Open Access Journals (Sweden)

    Amanda eFinan

    2015-09-01

    Full Text Available The healthy adult heart has a low turnover of cardiac myocytes. The renewal capacity, however, is augmented after cardiac injury. Participants in cardiac regeneration include cardiac myocytes themselves, cardiac progenitor cells, and peripheral stem cells, particularly from the bone marrow compartment. Cardiac progenitor cells and bone marrow stem cells are augmented after cardiac injury, migrate to the myocardium, and support regeneration. Depletion studies of these populations have demonstrated their necessary role in cardiac repair. However, the potential of these cells to completely regenerate the heart is limited. Efforts are now being focused on ways to augment these natural pathways to improve cardiac healing, primarily after ischemic injury but in other cardiac pathologies as well. Cell and gene therapy or pharmacological interventions are proposed mechanisms. Cell therapy has demonstrated modest results and has passed into clinical trials. However, the beneficial effects of cell therapy have primarily been their ability to produce paracrine effects on the cardiac tissue and recruit endogenous stem cell populations as opposed to direct cardiac regeneration. Gene therapy efforts have focused on prolonging or reactivating natural signaling pathways. Positive results have been demonstrated to activate the endogenous stem cell populations and are currently being tested in clinical trials. A potential new avenue may be to refine pharmacological treatments that are currently in place in the clinic. Evidence is mounting that drugs such as statins or beta blockers may alter endogenous stem cell activity. Understanding the effects of these drugs on stem cell repair while keeping in mind their primary function may strike a balance in myocardial healing. To maximize endogenous cardiac regeneration,a combination of these approaches couldameliorate the overall repair process to incorporate the participation ofmultiple cell players.

  18. Techniques for Identification of Left Ventricular Asynchrony for Cardiac Resynchronization Therapy in Heart Failure

    Directory of Open Access Journals (Sweden)

    Peter Schuster

    2005-07-01

    Full Text Available The most recent treatment option of medically refractory heart failure includes cardiac resynchronization therapy (CRT by biventricular pacing in selected patients in NYHA functional class III or IV heart failure. The widely used marker to indicate left ventricular (LV asynchrony has been the surface ECG, but seems not to be a sufficient marker of the mechanical events within the LV and prediction of clinical response. This review presents an overview of techniques for identification of left ventricular intra- and interventricular asynchrony. Both manuscripts for electrical and mechanical asynchrony are reviewed, partly predicting response to CRT. In summary there is still no gold standard for assessment of LV asynchrony for CRT, but both traditional and new echocardiographic methods have shown asynchronous LV contraction in heart failure patients, and resynchronized LV contraction during CRT and should be implemented as additional methods for selecting patients to CRT.

  19. Application of radionuclide ventriculography phase analysis in patients with atrial or ventricular pacing for detecting ventricular abnormal excitation

    International Nuclear Information System (INIS)

    Shi Rongfang; Wang Zhonggan; Li Shengting

    1996-01-01

    The aim of the study was to increase the accuracy of detecting ventricular abnormal excitation. During atrial or ventricular pacing, radionuclide ventriculography phase analysis (RNV-PA) was performed in 17 patients with Wolff-Parkinson-White (W-P-W) syndrome and paroxysmal supra ventricular tachycardia (PSVT) and ventricular tachycardia (PVT). During pacing, detection rate of abnormal excitation by RNV-PA was 95.5%, compared with 68.2% during basic conduction. Atrial or ventricular pacing can significantly increase the detection rate of abnormal excitation by RNV-PA in patients with W-P-W syndrome. It may be a valuable method for identifying the abnormal excitation and estimating the therapeutic effect of ablation

  20. Sound Effects for Children's Comprehension of Variably-Paced Television Programs.

    Science.gov (United States)

    Calvert, Sandra L.; Scott, M. Catherine

    In this study, children's selective attention to, and comprehension of, variably-paced television programs were examined as a function of sound effects. Sixty-four children, equally distributed by sex and by preschool and fourth grades, were randomly assigned to one of four treatment conditions which crossed two levels of sound effects (presence…

  1. Pacemaker Therapy in Patients With Neurally Mediated Syncope and Documented Asystole Third International Study on Syncope of Uncertain Etiology (ISSUE-3) A Randomized Trial

    NARCIS (Netherlands)

    Brignole, Michele; Menozzi, Carlo; Moya, Angel; Andresen, Dietrich; Blanc, Jean Jacques; Krahn, Andrew D.; Wieling, Wouter; Beiras, Xulio; Deharo, Jean Claude; Russo, Vitantonio; Tomaino, Marco; Sutton, Richard; Tomaino, M.; Pescoller, F.; Donateo, P.; Oddone, D.; Russo, V.; Pierri, F.; Matino, M. G.; Vitale, E.; Massa, R.; Piccinni, G.; Melissano, D.; Menozzi, C.; Lolli, G.; Gulizia, M.; Francese, M.; Iorfida, M.; Golzio, P.; Gaggioli, G.; Laffi, M.; Rabjoli, F.; Cecchinato, C.; Ungar, A.; Rafanelli, M.; Chisciotti, V.; Morrione, A.; del Rosso, A.; Guernaccia, V.; Palella, M.; D'Agostino, C.; Campana, A.; Brigante, M.; Miracapillo, G.; Addonisio, L.; Proclemer, A.; Facchin, D.; Vado, A.; Knops, R. E.; Dekker, L. R. C.

    2012-01-01

    Background-The efficacy of cardiac pacing for prevention of syncopal recurrences in patients with neurally mediated syncope is controversial. We wanted to determine whether pacing therapy reduces syncopal recurrences in patients with severe asystolic neurally mediated syncope. Methods and

  2. Atrial fibrillation after cardiac surgery

    Directory of Open Access Journals (Sweden)

    Nair Suresh

    2010-01-01

    Full Text Available Once considered as nothing more than a nuisance after cardiac surgery, the importance of postoperative atrial fibrillation (POAF has been realized in the last decade, primarily because of the morbidity associated with the condition. Numerous causative factors have been described without any single factor being singled out as the cause of this complication. POAF has been associated with stroke, renal failure and congestive heart failure, although it is difficult to state whether POAF is directly responsible for these complications. Guidelines have been formulated for prevention of POAF. However, very few cardiothoracic centers follow any form of protocol to prevent POAF. Routine use of prophylaxis would subject all patients to the side effects of anti-arrhythmic drugs, while only a minority of the patients do actually develop this problem postoperatively. Withdrawal of beta blockers in the postoperative period has been implicated as one of the major causes of POAF. Amiodarone, calcium channel blockers and a variety of other pharmacological agents have been used for the prevention of POAF. Atrial pacing is a non-pharmacological measure which has gained popularity in the prevention of POAF. There is considerable controversy regarding whether rate control is superior to rhythm control in the treatment of established atrial fibrillation (AF. Amiodarone plays a central role in both rate control and rhythm control in postoperative AF. Newer drugs like dronedarone and ranazoline are likely to come into the market in the coming years.

  3. Effect of atrial pacing on phase analysis in patients with the Wolff-Parkinson-White syndrome

    International Nuclear Information System (INIS)

    Magosaki, Nobuhisa; Hiroe, Michiaki; Kasanuki, Hiroshi; Ohnishi, Satoshi; Tanaka, Etsuko; Horie, Toshinobu; Kusakabe, Kiyoko; Kondo, Mizuka; Hirosawa, Koshichiro

    1984-01-01

    Phase analysis of ECG-gated radionuclide ventriculography was performed during sinus rhythm and atrial pacing for 11 patients with the Wolff-Parkinson-White (WPW) syndrome. During sinus rhythm, phase analysis demonstrated abnormal early-emptying segments reflecting preexcitation in six of the 11 patients. In the remaining five patients, the precise site of abnormal early-emptying could not be detected. Atrial pacing increased the degree of pre-exicitation, and abnormal early-emptying segments became clear in all patients. Our study demonstrated the utility of atrial pacing in performing phase analysis for patients with the WPW syndrome. Seven patients had abnormal early-emptying segments; four of them with ECG type A, in the left ventricle, and three of them with ECG type B, in the right ventricle. These results were consistent with results of the body surface and electrophysiologic mapping. In patients with posterior septal accessory pathways, phase analysis suggested probable laterality of the accessory pathway. (author)

  4. Different horse's paces during hippotherapy on spatio-temporal parameters of gait in children with bilateral spastic cerebral palsy: A feasibility study.

    Science.gov (United States)

    Antunes, Fabiane Nunes; Pinho, Alexandre Severo do; Kleiner, Ana Francisca Rozin; Salazar, Ana Paula; Eltz, Giovana Duarte; de Oliveira Junior, Alcyr Alves; Cechetti, Fernanda; Galli, Manuela; Pagnussat, Aline Souza

    2016-12-01

    Hippotherapy is often carried out for the rehabilitation of children with Cerebral Palsy (CP), with the horse riding at a walking pace. This study aimed to explore the immediate effects of a hippotherapy protocol using a walk-trot pace on spatio-temporal gait parameters and muscle tone in children with Bilateral Spastic CP (BS-CP). Ten children diagnosed with BS-CP and 10 healthy aged-matched children (reference group) took part in this study. The children with BS-CP underwent two sessions of hippotherapy for one week of washout between them. Two protocols (lasting 30min) were applied on separate days: Protocol 1: the horse's pace was a walking pace; and Protocol 2: the horse's pace was a walk-trot pace. Children from the reference group were not subjected to treatment. A wireless inertial measurement unit measured gait spatio-temporal parameters before and after each session. The Modified Ashworth Scale was applied for muscle tone measurement of hip adductors. The participants underwent the gait assessment on a path with surface irregularities (ecological context). The comparisons between BS-CP and the reference group found differences in all spatio-temporal parameters, except for gait velocity. Within-group analysis of children with BS-CP showed that the swing phase did not change after the walk pace and after the walk-trot pace. The percentage of rolling phase and double support improved after the walk-trot. The spasticity of the hip adductors was significantly reduced as an immediate result of both protocols, but this decrease was more evident after the walk-trot. The walk-trot protocol is feasible and is able to induce an immediate effect that improves the gait spatio-temporal parameters and the hip adductors spasticity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Cardiac rehabilitation

    Science.gov (United States)

    ... rehab; Heart failure - cardiac rehab References Anderson L, Taylor RS. Cardiac rehabilitation for people with heart disease: ... of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed ...

  6. Extraction of SelectSecure leads compared to conventional pacing leads in patients with congenital heart disease and congenital atrioventricular block.

    Science.gov (United States)

    Shepherd, Emma; Stuart, Graham; Martin, Rob; Walsh, Mark A

    2015-06-01

    SelectSecure™ pacing leads (Medtronic Inc) are increasingly being used in pediatric patients and adults with structural congenital heart disease. The 4Fr lead is ideal for patients who may require lifelong pacing and can be advantageous for patients with complex anatomy. The purpose of this study was to compare the extraction of SelectSecure leads with conventional (stylette-driven) pacing leads in patients with structural congenital heart disease and congenital atrioventricular block. The data on lead extractions from pediatric and adult congenital heart disease (ACHD) patients from August 2004 to July 2014 at Bristol Royal Hospital for Children and the Bristol Heart Institute were reviewed. Multivariable regression analysis was used to determine whether conventional pacing leads were associated with a more difficult extraction process. A total of 57 patients underwent pacemaker lead extractions (22 SelectSecure, 35 conventional). No deaths occurred. Mean age at the time of extraction was 17.6 ± 10.5 years, mean weight was 47 ± 18 kg, and mean lead age was 5.6 ± 2.6 years (range 1-11 years). Complex extraction (partial extraction/femoral extraction) was more common in patients with conventional pacing leads at univariate (P < .01) and multivariate (P = .04) levels. Lead age was also a significant predictor of complex extraction (P < .01). SelectSecure leads can be successfully extracted using techniques that are used for conventional pacing leads. They are less likely to be partially extracted and are less likely to require extraction using a femoral approach compared with conventional pacing leads. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  7. Investigating the Effects of Concurrent Performance of Physical and Cognitive Demanding Task in Paced Assembly Lines

    Directory of Open Access Journals (Sweden)

    Shakil Ahmed Shaikh

    2013-07-01

    Full Text Available The study was undertaken to investigate the effects of pacing on aspects of performance at an assembly task and on the operators' responses related to work behaviour, perceived workload and perceived stress. A particular objective of the study was to investigate whether physical and cognitive demands may interact in their influences on these effects. An assembly task was simulated in the laboratory and the level of pacing imposed, work height and memory load within the task were all varied. The results showed that the type of pacing commonly imposed (as is common with a lean manufacturing Takt time system in industry can significantly affect both performance and perceived workload and stress. Physical demands (through work height affecting posture and mental demand (through memory load were also found to have significant effects, as would be expected from the many studies of these in the literature. More importantly, some interactions were found between pacing and work height in their effects on quality of assembly and the operator's own rating of performance, and between work height and memory load in their effects on errors. These findings will need to be taken into account by companies when implementing Takt time systems.

  8. [Outcomes and predictors of mortality in elderly patients requiring artificial ventilation].

    Science.gov (United States)

    Murai, Y; Matsumiya, H; Takemura, H; Koinuma, M

    2000-07-01

    We retrospectively examined the outcomes and the predictors of mortality in 97 patients aged 70 years and over (mean: 79.3 years) who required artificial ventilation for more than 3 hours. The median duration of artificial ventilation was 16 days (range: 1-85). Of these patients, 61% survived ventilator weaning and 37% were discharged from hospital alive. We performed univariate and logistic regression analysis to determine the predictors of dying before weaning and hospital discharge using severity of illness data. The predictors of hospital mortality were examined in 86 patients, excluding those who had malignant disease, all of whom died in hospital. Activities of daily living (ADL) were ranked as "bedridden", "in wheelchair", or "independent". In the three age groups-up to 70 years, 75 to 84 years and 85 years and over-the respective survival rates were 63% (weaned) and 67% (discharged), 69% (weaned) and 39% (discharged), and 33% (weaned) and 12% (discharged); the overall p values being 0.026 (weaned) and 0.003 (discharged). The predictors of dying before weaning according to univariate analysis were as follows: age (p = 0.026), respiratory or cardiac arrest on admission (p = 0.003), acute physiology score (APS) of 25 or more on admission (p = 0.000), systolic blood pressure below 90 mmHg on admission (p = 0.001), hemoglobin less than 11 g/dl (p = 0.044), and total protein less than 6 g/dl (p = 0.007). The predictors of hospital mortality by univariate analysis were as follows: age (p = 0.003), limited ADL (p = 0.001), respiratory or cardiac arrest on admission (p = 0.011), APS 25 or more on admission (p = 0.049), systolic blood pressure less than 90 mmHg on admission (p = 0.002), hemoglobin less than 11 g/dl (p = 0.028), and GOT or GPT more than 50 IU (p = 0.038). The relative risk of dying before weaning decreased in the order: respiratory or cardiac arrest on admission, systolic blood pressure less than 90 mmHg on admission, total protein less than 6 g

  9. A projection-adapted cross entropy (PACE) method for transmission network planning

    Energy Technology Data Exchange (ETDEWEB)

    Eshragh, Ali; Filar, Jerzy [University of South Australia, School of Mathematics and Statistics, Mawson Lakes, SA (Australia); Nazar, Asef [University of South Australia, Institute for Sustainable Systems Technologies, School of Mathematics and Statistics, Mawson Lakes, SA (Australia)

    2011-06-15

    In this paper, we propose an adaptation of the cross entropy (CE) method called projection-adapted CE (PACE) to solve a transmission expansion problem that arises in management of national and provincial electricity grids. The aim of the problem is to find an expansion policy that is both economical and operational from the technical perspective. Often, the transmission network expansion problem is mathematically formulated as a mixed integer nonlinear program that is very challenging algorithmically. The challenge originates from the fact that a global optimum should be found despite the presence, of possibly a huge number, of local optima. The PACE method shows promise in solving global optimization problems regardless of continuity or other assumptions. In our approach, we sample the integer variables using the CE mechanism, and solve LPs to obtain matching continuous variables. Numerical results, on selected test systems, demonstrate the potential of this approach. (orig.)

  10. Towards Development of a 3-State Self-Paced Brain-Computer Interface

    Directory of Open Access Journals (Sweden)

    Ali Bashashati

    2007-01-01

    the presence of a right- or a left-hand movement and the second classifies the detected movement as a right or a left one. In an offline analysis of the EEG data collected from four able-bodied individuals, the 3-state brain-computer interface shows a comparable performance with a 2-state system and significant performance improvement if used as a 2-state BCI, that is, in detecting the presence of a right- or a left-hand movement (regardless of the type of movement. It has an average true positive rate of 37.5% and 42.8% (at false positives rate of 1% in detecting right- and left-hand extensions, respectively, in the context of a 3-state self-paced BCI and average detection rate of 58.1% (at false positive rate of 1% in the context of a 2-state self-paced BCI.

  11. Impact of thoracic surgery on cardiac morphology and function in small animal models of heart disease: a cardiac MRI study in rats.

    Directory of Open Access Journals (Sweden)

    Peter Nordbeck

    Full Text Available BACKGROUND: Surgical procedures in small animal models of heart disease might evoke alterations in cardiac morphology and function. The aim of this study was to reveal and quantify such potential artificial early or long term effects in vivo, which might account for a significant bias in basic cardiovascular research, and, therefore, could potentially question the meaning of respective studies. METHODS: Female Wistar rats (n = 6 per group were matched for weight and assorted for sham left coronary artery ligation or control. Cardiac morphology and function was then investigated in vivo by cine magnetic resonance imaging at 7 Tesla 1 and 8 weeks after the surgical procedure. The time course of metabolic and inflammatory blood parameters was determined in addition. RESULTS: Compared to healthy controls, rats after sham surgery showed a lower body weight both 1 week (267.5±10.6 vs. 317.0±11.3 g, n<0.05 and 8 weeks (317.0±21.1 vs. 358.7±22.4 g, n<0.05 after the intervention. Left and right ventricular morphology and function were not different in absolute measures in both groups 1 week after surgery. However, there was a confined difference in several cardiac parameters normalized to the body weight (bw, such as myocardial mass (2.19±0.30/0.83±0.13 vs. 1.85±0.22/0.70±0.07 mg left/right per g bw, p<0.05, or enddiastolic ventricular volume (1.31±0.36/1.21±0.31 vs. 1.14±0.20/1.07±0.17 µl left/right per g bw, p<0.05. Vice versa, after 8 weeks, cardiac masses, volumes, and output showed a trend for lower values in sham operated rats compared to controls in absolute measures (782.2±57.2/260.2±33.2 vs. 805.9±84.8/310.4±48.5 mg, p<0.05 for left/right ventricular mass, but not normalized to body weight. Matching these findings, blood testing revealed only minor inflammatory but prolonged metabolic changes after surgery not related to cardiac disease. CONCLUSION: Cardio-thoracic surgical procedures in experimental myocardial infarction

  12. The impact of the perception of rhythmic music on self-paced oscillatory movements.

    Science.gov (United States)

    Peckel, Mathieu; Pozzo, Thierry; Bigand, Emmanuel

    2014-01-01

    Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping) while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20 s before a 2 s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced) while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with the task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e., motor/perceptual resonance). In general, our results give support to the notion that rhythmic music is processed in a motoric

  13. The impact of the perception of rhythmic music on oscillatory self-paced movements

    Directory of Open Access Journals (Sweden)

    Mathieu ePeckel

    2014-09-01

    Full Text Available Inspired by theories of perception-action coupling and embodied music cognition, we investigated how rhythmic music perception impacts self-paced oscillatory movements. In a pilot study, we examined the kinematic parameters of self-paced oscillatory movements, walking and finger tapping using optical motion capture. In accordance with biomechanical constraints accounts of motion, we found that movements followed a hierarchical organization depending on the proximal/distal characteristic of the limb used. Based on these findings, we were interested in knowing how and when the perception of rhythmic music could resonate with the motor system in the context of these constrained oscillatory movements. In order to test this, we conducted an experiment where participants performed four different effector-specific movements (lower leg, whole arm and forearm oscillation and finger tapping while rhythmic music was playing in the background. Musical stimuli consisted of computer-generated MIDI musical pieces with a 4/4 metrical structure. The musical tempo of each song increased from 60 BPM to 120 BPM by 6 BPM increments. A specific tempo was maintained for 20s before a 2s transition to the higher tempo. The task of the participant was to maintain a comfortable pace for the four movements (self-paced while not paying attention to the music. No instruction on whether to synchronize with the music was given. Results showed that participants were distinctively influenced by the background music depending on the movement used with the tapping task being consistently the most influenced. Furthermore, eight strategies put in place by participants to cope with task were unveiled. Despite not instructed to do so, participants also occasionally synchronized with music. Results are discussed in terms of the link between perception and action (i.e. motor/perceptual resonance. In general, our results give support to the notion that rhythmic music is processed in a

  14. Defining the Intrinsic Cardiac Risks of Operations to Improve Preoperative Cardiac Risk Assessments.

    Science.gov (United States)

    Liu, Jason B; Liu, Yaoming; Cohen, Mark E; Ko, Clifford Y; Sweitzer, Bobbie J

    2018-02-01

    Current preoperative cardiac risk stratification practices group operations into broad categories, which might inadequately consider the intrinsic cardiac risks of individual operations. We sought to define the intrinsic cardiac risks of individual operations and to demonstrate how grouping operations might lead to imprecise estimates of perioperative cardiac risk. Elective operations (based on Common Procedural Terminology codes) performed from January 1, 2010 to December 31, 2015 at hospitals participating in the American College of Surgeons National Surgical Quality Improvement Program were studied. A composite measure of perioperative adverse cardiac events was defined as either cardiac arrest requiring cardiopulmonary resuscitation or acute myocardial infarction. Operations' intrinsic cardiac risks were derived from mixed-effects models while controlling for patient mix. Resultant risks were sorted into low-, intermediate-, and high-risk categories, and the most commonly performed operations within each category were identified. Intrinsic operative risks were also examined using a representative grouping of operations to portray within-group variation. Sixty-six low, 30 intermediate, and 106 high intrinsic cardiac risk operations were identified. Excisional breast biopsy had the lowest intrinsic cardiac risk (overall rate, 0.01%; odds ratio, 0.11; 95% CI, 0.02 to 0.25) relative to the average, whereas aorto-bifemoral bypass grafting had the highest (overall rate, 4.1%; odds ratio, 6.61; 95% CI, 5.54 to 7.90). There was wide variation in the intrinsic cardiac risks of operations within the representative grouping (median odds ratio, 1.40; interquartile range, 0.88 to 2.17). A continuum of intrinsic cardiac risk exists among operations. Grouping operations into broad categories inadequately accounts for the intrinsic cardiac risk of individual operations.

  15. Assessing the PACE of California residential solar deployment: Impacts of Property Assessed Clean Energy programs on residential solar photovoltaic deployment in California, 2010-2015

    Energy Technology Data Exchange (ETDEWEB)

    Deason, Jeff; Murphy, Sean

    2018-04-04

    A new study by Berkeley Lab found that residential Property Assessed Clean Energy (R-PACE) programs increased deployment of residential solar photovoltaic (PV) systems in California, raising it by about 7-12% in cities that adopt these programs. R-PACE is a financing mechanism that uses a voluntary property tax assessment, paid off over time, to facilitate energy improvements and, in some jurisdictions, water and resilience measures. While previous studies demonstrated that early, regional R-PACE programs increased solar PV deployment, this new analysis is the first to demonstrate these impacts from the large, statewide R-PACE programs dominating the California market today, which use private capital to fund the upfront costs of the improvements. Berkeley Lab estimated the impacts using econometric techniques on two samples: -Large cities only, allowing annual demographic and economic data as control variables -All California cities, without these annual data Analysis of both samples controls for several factors other than R-PACE that would be expected to drive solar PV deployment. We infer that on average, cities with R-PACE programs were associated with greater solar PV deployment in our study period (2010-2015). In the large cities sample, solar PV deployment in jurisdictions with R-PACE programs was higher by 1.1 watts per owner-occupied household per month, or 12%. Across all cities, solar PV deployment in jurisdictions with R-PACE programs was higher by 0.6 watts per owner-occupied household per month, or 7%. The large cities results are statistically significant at conventional levels; the all-cities results are not. The estimates imply that the majority of solar PV deployment financed by R-PACE programs would likely not have occurred in their absence. Results suggest that R-PACE programs have increased PV deployment in California even in relatively recent years, as R-PACE programs have grown in market share and as alternate approaches for financing solar PV

  16. The corticospinal responses of metronome-paced, but not self-paced strength training are similar to motor skill training.

    Science.gov (United States)

    Leung, Michael; Rantalainen, Timo; Teo, Wei-Peng; Kidgell, Dawson

    2017-12-01

    The corticospinal responses to skill training may be different to strength training, depending on how the strength training is performed. It was hypothesised that the corticospinal responses would not be different following skill training and metronome-paced strength training (MPST), but would differ when compared with self-paced strength training (SPST). Corticospinal excitability, short-interval intra-cortical inhibition (SICI) and strength and tracking error were measured at baseline and 2 and 4 weeks. Participants (n = 44) were randomly allocated to visuomotor tracking, MPST, SPST or a control group. MPST increased strength by 7 and 18%, whilst SPST increased strength by 12 and 26% following 2 and 4 weeks of strength training. There were no changes in strength following skill training. Skill training reduced tracking error by 47 and 58% at 2 and 4 weeks. There were no changes in tracking error following SPST; however, tracking error reduced by 24% following 4 weeks of MPST. Corticospinal excitability increased by 40% following MPST and by 29% following skill training. There was no change in corticospinal excitability following 4 weeks of SPST. Importantly, the magnitude of change between skill training and MPST was not different. SICI decreased by 41 and 61% following 2 and 4 weeks of MPST, whilst SICI decreased by 41 and 33% following 2 and 4 weeks of skill training. Again, SPST had no effect on SICI at 2 and 4 weeks. There was no difference in the magnitude of SICI reduction between skill training and MPST. This study adds new knowledge regarding the corticospinal responses to skill and MPST, showing they are similar but different when compared with SPST.

  17. Effects of wind application on thermal perception and self-paced performance

    NARCIS (Netherlands)

    Teunissen, L.P.J.; Haan, A. de; Koning, J.J. de; Daanen, H.A.M.

    2013-01-01

    Physiological and perceptual effects of wind cooling are often intertwined and have scarcely been studied in self-paced exercise. Therefore, we aimed to investigate (1) the independent perceptual effect of wind cooling and its impact on performance and (2) the responses to temporary wind cooling

  18. Extrinsic and intrinsic factors associated with non-contact injury in adult pace bowlers: a systematic review protocol.

    Science.gov (United States)

    Olivier, Benita; Stewart, Aimee; Taljaard, Tracy; Burger, Elaine; Brukner, Peter; Orchard, John; Gray, Janine; Botha, Nadine; Mckinon, Warrick

    2015-01-01

    Review question: which extrinsic and intrinsic factors are associated with non-contact injury in adult cricket pace bowlers?Review objective: the objective of this review is to determine the extrinsic and intrinsic factors associated with non-contact injury in adult pace bowlers. Cricket is generally considered to be a sport of low injury risk compared to other sports. In cricket, the pace bowler strives towards the adoption of a bowling technique with a relatively low injury threat that will, at the same time, allow for a fast (>120km/hr) and accurate delivery to the opposing batsman. However, of all the various roles of the cricket player, the pace bowler has the highest risk of injury, especially for low back and lower limb (lower quarter) injury. The reason for this high risk of injury is due to the inherent, high-load biomechanical nature of the pace bowling action. The high prevalence of injury amongst pace bowlers highlights the great need for research into factors associated with injury.Both extrinsic and intrinsic factors work in combination to predispose the bowler to injury. Extrinsic or environment-related factors include bowling workload (the numbers of overs a bowler bowls), player position (first, second or third change) and time of play (morning or afternoon). A high bowling workload has been linked with a higher risk of injury in pace bowlers. Foster et al. found in an observational study that bowling too many overs in a single spell or bowling too many spells may increase the pace bowler's risk of sustaining a low back injury. In another observational study, Dennis et al. found that an exceptionally high bowling workload as well as an uncommonly low bowling workload is associated with injury risk. The major extrinsic factors for bowling injury identified by Orchard et al. are a high number of match overs bowled in the previous week, number of days of play and bowling second (batting first) in a match. Extrinsic factors are known to make the bowler

  19. Heart rate autonomic regulation system at rest and during paced breathing among patients with CRPS as compared to age-matched healthy controls.

    Science.gov (United States)

    Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal

    2014-09-01

    The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.

  20. Pulmonary Right Ventricular Resynchronization in Congenital Heart Disease: Acute Improvement in Right Ventricular Mechanics and Contraction Efficiency.

    Science.gov (United States)

    Janoušek, Jan; Kovanda, Jan; Ložek, Miroslav; Tomek, Viktor; Vojtovič, Pavel; Gebauer, Roman; Kubuš, Peter; Krejčíř, Miroslav; Lumens, Joost; Delhaas, Tammo; Prinzen, Frits

    2017-09-01

    Electromechanical discoordination may contribute to long-term pulmonary right ventricular (RV) dysfunction in patients after surgery for congenital heart disease. We sought to evaluate changes in RV function after temporary RV cardiac resynchronization therapy. Twenty-five patients aged median 12.0 years after repair of tetralogy of Fallot and similar lesions were studied echocardiographically (n=23) and by cardiac catheterization (n=5) after primary repair (n=4) or after surgical RV revalvulation for significant pulmonary regurgitation (n=21). Temporary RV cardiac resynchronization therapy was applied in the presence of complete right bundle branch block by atrial-synchronized RV free wall pacing in complete fusion with spontaneous ventricular depolarization using temporary electrodes. The q-RV interval at the RV free wall pacing site (mean 77.2% of baseline QRS duration) confirmed pacing from a late activated RV area. RV cardiac resynchronization therapy carried significant decrease in QRS duration ( P right bundle branch block QRS morphology, increase in RV filling time ( P =0.002), pulmonary artery velocity time integral ( P =0.006), and RV maximum +dP/dt ( P right bundle branch block, RV cardiac resynchronization therapy carried multiple positive effects on RV mechanics, synchrony, and contraction efficiency. © 2017 American Heart Association, Inc.