The primary objective of this study was to evaluate the potential environmental effects (both adverse and beneficials) of aquifer thermal energy storage (ATES) technology pertaining to microbial communities indigenous to subsurface environments (i.e., aquifers) and the propagation, movement, and potential release of pathogenic microorganisms (specifically, Legionella) within ATES systems. Seasonal storage of thermal energy in aquifers shows great promise to reduce peak demand; reduce electric utility load problems; contribute to establishing favorable economics for district heating and cooling systems; and reduce pollution from extraction, refining, and combustion of fossil fuels. However, concerns that the widespread implementation of this technology may have adverse effects on biological systems indigeneous to aquifers, as well as help to ...
Hydrology and hydrogeochemical are auxiliary techniques to valid conceptual hydrogeology an recharge models. Stable isotopes from water trace sources and path flow and Tritium indicates age. This paper is about the use of D 18, D2H y 3H to study the aquifersystem on Bajo Cauca antioqueno.
Author.The geochemical and isotopic study, based on the analysis of twenty water samples from well in the coastal plain of Sarafand (South-Lebanon), permit to eliminate the hypothesis of marine intrusion in this aquifer. The increase of salinity observed in certain wells is due to the contamination of cretaceous aquifer water by the quaternary formations. The two poles of mixing are respectively characterized: by weak tritium contents (between 2 and 3 UT) and a value of stable isotopes (-5,9<0,18<-5,5) corresponding to the appearance of cretaceous formation area; by the high tritium contents and enrichment relative to heavy isotope in the mineralized water of superficial formations. On the other hand, the isotope contents permit the set a rapid renewal of the cretaceous aquifer water due to quick circulation in the Karstic system
Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have ...
Storage of thermal energy in aquifers has obvious benefits of saving energy and decreasing the consumption of fossil fuels. However, aquifer thermal energy storage (ATES), which involves groundwater aquifers as the storage medium for heat or chill, impinges on the environment. A literature review of pertinent microbiology publications (Hicks and Stewart, 1988) identified the potential for the interaction of ATES systems and microbiological processes to create a source of infectious diseases and the potential for damage to the environment. In addition, the review identified a potential for microbiological processes to develop conditions that would interfere with the operation of an ATES system. As a result of this research effort, investigators from Finland, Germany, Switzerland, and the United States have examined several ATES systems in operation and have ...
The purpose of the piezometer network is to establish baseline hydraulic head data for the water table aquifer at the F- and H-Area seeplines prior to startup of the groundwater extraction/injection remediation system.
... Construction, Geology, and Aquifer Testing of the Maalo ... 8-98) Prescribed by ANSI Std Z39-18 Page 3. Construction, Geology, and Aquifer Testing ...
The U.S. Geological Survey, in cooperation with the U.S. Department of Energy, is conducting a study to determine the natural geochemistry of the Snake River Plain aquifersystem at the Idaho National Engineering Laboratory (INEL), Idaho. As part of this study, a group of geochemical reactions that partially control the natural chemistry of ground water at the INEL were identified. Mineralogy of the aquifer matrix was determined using X-ray diffraction and thin-section analysis and theoretical stabilities of the minerals were used to identify potential solid-phase reactants and products of the reactions. The reactants and products that have an important contribution to the natural geochemistry include labradorite, olivine, pyroxene, smectite, calcite, ferric oxyhydroxide, and several silica phases. To further identify the reactions, analyses of 22 representative water samples from sites tapping the Snake River Plain ...
The contribution outlines the current status of the building construction projects for the German Bundestag in Berlin. The following subjects are discussed: Energetic quality of the building, energy supply concept, integrated energy supply system, electric CHP systems, cogeneration (vegetable oil), aquifer storage (heat storage, cold storage), solar energy (photovoltaic energy conversion, thermal solar energy use), economic and ecological aspects. (HW) [Deutsch] Der vorliegende Beitrag gibt einen Ueberblick ueber den aktuellen Stand des Bauvorhabens des Deutschen Bundestages in Berlin. In diesem Zusammenhang wird auf folgende Themen eingegangen: Energetische Gebaeudequalitaet, Energieversorgungskonzept, Energieverbund, stromgefuehrte BHKWs, Kraft-Waerme-Kopplung (Pflanzenoel), Aquiferspeicher (Waermespeicher, Kaeltespeicher), Sonnenergienutzung (Photovoltaik, thermische Solarenergienutzung), Wirtschaftlichkeit und ...
Because of the environmental hazard of organic solvents such as chlorinated or aromatic hydrocarbons, water soluble and biodegradable substitutes have come into use. It should be assessed how they affect soil and aquifer when spilled in leaks or accidents. This was simulated in a model system using methanol and percolation columns, one filled with material from the unsaturated subsurface and two with different materials from aquifers. The results reveal that a spill of the substitutes can also cause problems. In homogeneous soils and at long retention times until the substance reaches the aquifer, sorption and biological degradation are most likely to prevent contamination of the groundwater. When oxygen supply in the subsurface is insufficient, reducing conditions occur and sulphide is formed. The data show that much more methanol was eliminated than reflected by the consumption of electron acceptors. ...
In this paper we provide a geochemical investigation on 34 groundwater samples in the Mt. Vulture volcanic aquifer representing one of the most important groundwater resources of the southern Italy pumped for drinking and irrigation supply. The present study includes the first data on the abundance and mobility of minor and trace elements and the thermodynamic considerations on water-rock interaction processes in order to evaluate the conditions of alkali basalt weathering by waters enriched in magma-derived CO2. The results highlight the occurrence of two hydrofacies: bicarbonate alkaline-earth and alkaline waters deriving from low-temperature leaching of volcanic rocks of Mt. Vulture, and bicarbonate-sulfate-alkaline waters (high-salinity waters) related to prolonged water circulation in...
This report presents the status of development of a three-dimensional conceptual model for the unconfined aquifersystem at Hanford. A conceptual model is needed to support development of a realistic three-dimensional numerical model for predicting ground-water flow and the transport of contaminants. The report focuses on developing a hydrogeologic framework, assessing available hydraulic property data, describing flow-system boundaries, and evaluating areal recharge and leakage. Geologic descriptions of samples obtained during well drilling were used to prepare cross sections that correlate relatively continuous layers. The layers were defined based on textural differences that are expected to reflect differences in hydraulic properties. Assigning hydraulic properties to the layers is a critical part of the conceptual model. Available hydraulic property data for the study area were compiled and were correlated with the ...
The overall goal of the proposed project is to explore the use of partitioning tracers to characterize dense nonaqueous phase liquids (DNAPLs) in aquifersystems. Bulk-phase partitioning tracers will be investigated to detect and determine DNAPL saturation, while interface partitioning tracers will be investigated to measure the area of the DNAPL-water interface. The specific objectives that will be addressed to accomplish this goal are: (1) Investigate the use of partitioning tracers to detect and determine both the saturation and interfacial area of DNAPLs in saturated porous media. (2) Investigate the effect of rate-limited mass transfer on the transport behavior of partitioning tracers. (3) Investigate the effect of porous-media heterogeneity on the transport behavior of partitioning tracers. (4) Develop and evaluate mathematical models capable of simulating the transport of partitioning tracers in complex systems. This ...
An initial review was conducted of the current treatment operations for remediation of groundwater contaminated with trichloroethene (TCE) at the Fort lewis Logistics Center. Results from this review indicate the two pump-and-treat systems are effectively containing the TCE plume within the upper unconfined aquifer (Vashon Drift). However, mass balance calculations show the existing treatment systems alone will not accomplish the remedial action objective of cleaning up the aquifer to drinking water standards within 30 years as specified in the Record of Decision (ROD). This conclusion is based on the estimated mass of TCE at the source term (51,000 kg), the calculated mass of TCE in the aquifer (4,900 kg), and the removal rate of the pump-and-treat systems that currently ranges from 324 to 667 kg of TCe per year. Four areas within the TCE plume have been ...
A two-dimensional mathematical model of a fault controlled geothermal reservoir has been developed. Heated water rising in a fault is assumed to charge a reservoir which is overlain by a thin impermeable, thermally conducting cap rock. The mass flow rate or the pressure associated with the charging process at the fault inlet is unknown and can only be estimated. Thus, the pressure in the fault at the bottom of the reservoir is assumed to be prescribed. Quasi-analytic solutions for the distributions of velocity, pressure, and temperature are obtained in the fault-reservoir system for high Rayleigh number flow. In this approximation, the upwelling fluid does not cool off appreciably until it reaches the cold upper boundary of the reservoir and encounters conductive heat loss. The thermal boundary layer, which is thin at the top of the fault, grows outward laterally and occupies the full thickness of the aquifer in the far-field. This study shows ...
In many parts of the United States, as well as other regions of the world, competing demands for fresh water or water suitable for desalination are outstripping sustainable supplies. In these areas, new water supplies are necessary to sustain economic development and agricultural uses, as well as support expanding populations, particularly in the Southwestern United States. Increasing the supply of water will more than likely come through desalinization of water reservoirs that are not suitable for present use. Surface-deployed seismic and electromagnetic (EM) methods have the potential for addressing these critical issues within large volumes of an aquifer at a lower cost than drilling and sampling. However, for detailed analysis of the water quality, some sampling utilizing boreholes would be required with geophysical methods being employed to extrapolate these sampled results to non-sampled regions of the aquifer. The research in this report ...
Ground-water monitoring near the Raft River site was initiated in 1974 by the IDWR. This effort consisted of semiannual chemical sampling of 22 irrigation wells near the Raft River geothermal development area. This program yielded useful baseline chemical data; however, several problems were inherent. For example, access to water pumped from the wells is limited to the irrigation season (April through September). All the wells are not continuously pumped; thus, some wells that are sampled one season cannot be sampled the next. In addition, information on well construction, completion, and production is often unreliable or not available. These data are to be supplemented by establishing a series of monitor wells in the proposed geothermal withdrawal and injection area. These wells were to be located and designed to provide data necessary for evaluating and predicting the impact of geothermal development on the Shallow Aquifersystem.
The transport and partitioning of {sup 129}I has been examined for a shallow groundwater flow system at Sturgeon Falls in northeastern Ontario. Recharge into a sandy surficial postglacial deltaic aquifer occurs in the vicinity of a seasonally-wet boreal forest. Concentrations of stable iodine, {sup 129}I, tritium, radiocarbon, stable isotopes and major ions were measured on samples of groundwater and precipitation. The present-day tritium profile delineates the position of the early 1960's above-ground nuclear weapons pulse at a depth of approximately 12 m. The concentrations of stable iodine for groundwaters above, near and below the above-ground nuclear weapons pulse range from 0.07 to 1.7 ppb. Over that same interval {sup 129}I concentrations decreased from 1.9 x 10{sup 6} atoms/L at 9 m, to approximately 1.9 x 10{sup 5} atoms/L in tritium-depleted waters at 35 m, below the present-day depth of the recharging above-ground nuclear ...
In 2000, a network of twenty-three piezometers was used to measure hydraulic head in the water-table aquifer (Upper Aquifer Zone of the Upper Three Runs Aquifer, or UAZ of the UTRA) along the ground water outcrops (i.e. seeplines) near the F- and H-Areas.
Geothermal energy appears as a viable economic alternative among the different renewable energy sources. The French bureau of geological and mining researches (BRGM) is involved in several research and development programs in the domain of geothermal energy and underground reservoirs. This document presents the content of 5 programs: the deep hot dry rock system of Soultz-sous-Forets (construction and testing of the scientific pilot, modeling of the reservoir structure), the development of low and high enthalpy geothermal energy in the French West Indies, the comparison of the geothermal development success of Bouillante (Guadeloupe, French West Indies) with the check of the geothermal development of Nyssiros (Greece) and Pantelleria (Italy), the development of the high enthalpy geothermal potentialities of Reunion Island, and the underground storage of CO{sub 2} emissions in geologic formations (deep aquifers, geothermal reservoirs, abandoned ...
Abstract The present study makes use of a detailed water balance to investigate the hydrological status of a peatland with a basal clay-rich layer overlying an aquifer exploited for drinking water. The aim is to determine the influence of climate and groundwater extraction on the water balance and water levels in the peatland. During the two-year period of monitoring, the hydrological functioning of the wetland showed a hydric deficit, associated with a permanent unsaturated layer and a deep water table. At the same time, a stream was observed serving as a recharge inflow instead of draining the peatland, as usually described in natural systems. Such conditions are not favourable for peat accumulation. Field investigations show that the clay layer has a high hydraulic conductivity (from 11...
Geologic sequestration is currently being practiced and scientifically evaluated as a critical component in a broad strategy, comprising new practices and technologies, for mitigating global climate change due to anthropogenic emissions of CO2. Demonstrating that geologic sequestration of CO2 is safe and effective, and gaining public acceptance of sequestration technologies are critically important in meeting these global climate change challenges. Monitored field-scale demonstrations of geologic sequestration of carbon dioxide will contribute greatly toward growing trust and confidence in the technology; however, pilot demonstrations ultimately will not be the norm for new geological sequestration deployments. Instead, scientists, engineers, regulators, and ultimately the public will rely on numerical simulations to predict the performance of geologic repositories for carbon dioxide sequestration. The U.S. Department of Energy (DOE), through the National Environmental Technology ...
The twin-cities of El Paso and Juarez share the water resources of the Hueco Bolson aquifer and overlying Rio Grande aquifer. Both aquifers span the international border between Mexico and the United States. Salinity in the Rio Grande aquifer varies widely, some parts of the shallow aquifer containing less than 1,000 mg/L total dissolved solids (TDS), other parts of the aquifer exceeding 5,000 mg/L TDS. One sizable part of the "Lower Valley" area, approximately 45 km below El Paso contains very dilute water near the outer edge of the floodplain. Historically it had been thought that the dilute waters in this location were derived from recharge from arroyos that drained proximal parts of the Hueco Bolson. Instead, our hydrogen and oxygen isotope data and carbon-14 data indicate that these dilute waters were derived from pre-dam infiltration of the Rio Grande. ...
A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass ...
Eukaryotes may influence pollutant degradation processes in groundwater ecosystems by activities such as predation on bacteria and recycling of nutrients. Culture-independent community profiling and...Full Text Available
In 1996, a field-scale phytoremediation demonstration project was initiated and managed by the U.S. Air Force at a site in western Fort Worth, Texas, using a plantation of 1-year-old stems harvested from branches of eastern cottonwoods during the dormant season (whips) and a plantation of 1-year-old eastern cottonwood seedlings (calipers). The primary objective of the demonstration project was to determine the effectiveness of eastern cottonwoods at reducing the mass of dissolved trichloroethene transported within an alluvial aquifer. The U.S. Geological Survey conducted a study, in cooperation with the U.S. Air Force, to determine water-level variations and their effects on tree growth and mortality and on the biogeochemical system at the phytoremediation site. As part of the study, water-level and water-quality data were collected throughout the duration of the project. This report presents water-level variations at periodic sampling ...
The Idaho Chemical Processing Plant (ICPP) Water inventory Study was initiated in September 1993 with the formation of a joint working group consisting of representatives from DOE-ID, State of Idaho INEL Oversight Program, US Geological Survey, and INEL employees to investigate three issues that had been identified by the INEL Oversight Program at ICPP: (1) the water inventory imbalance at ICPP, (2) the source of water infiltrating into the Tank Farm vault sumps, and (3) the source of water providing potential recharge to perched water bodies underlying ICPP. These issues suggested that water was being lost from the ICPP distribution system. The INEL Oversight Program was concerned that the unaccounted for water at ICPP could be spreading contaminants that have been released over the past 40 years of operations of ICPP, possibly to the Snake River Plain Aquifer. This report summarizes the findings of each of the component investigations that ...
The European gas market is continuing to expand due to increased industrial, domestic and power generation demand. As a result of this demand, and the trend toward liberalization of the market, the need for storage of gas is also increasing. One key segment of the large scale storage of gas is underground storage, either in partially depleted gas or oil fields, naturally occurring caverns, aquifers and salt cavities. In most cases the gas produced after storage requires conditioning to meet the water of hydrocarbon dew point specification of the gas transmission system. For that reason export gas from storage will require gas conditioning in order to meet pipeline specifications. Adsorption as a feasible and reliable process will be presented in detail and especially in regards to hydrocarbon dew-pointing compared with other process options. (author)
Total EU (and Norway) emissions of CO_2 from thermal power generation were some 950 million tonnes in 1990, the Kyoto agreement reference level. An ongoing research project, the GESTCO project, will provide the first documentation that, for the emission sources within the selected key areas, sufficient geological storage capacity is available for at least 30 years and possibly much longer. Cost of energy will obviously increase, but it is anticipated that electricity production cost price will be comparable to that of renewables. It would further have major implications for the European power generating industry which today is totally dominated by fossil fuel combustion with enormous emissions problems. The identification and siting of subsurface CO_2 storage capability can be expected to have considerable effect on the planning for and future siting of fossil fuel plants. In Norway there are plans to build several major, coastally sited, natural gas-fed electricity generating plants. ...
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams, Energy Systems, through Geraghty and Miller, Inc., conducted an initial dye-tracer study during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. Based on the results of the initial study, Energy Systems recommended to the Tennessee Department of Environment and ...
Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.
Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the subsurface; and field testing and evaluation of methods proposed to restore and cleanup contaminated ...
The project was initiated in 1985 with the goal of studying existing federal, state, and local programs for protecting and preserving Cape Cod's sole-source aquifer. To meet this need, the Massachusetts Department of Environmental Quality Engineering and the U.S. Environmental Protection Agency's Region 1 in cooperation with the Cape Cod Planning and Economic and Development Commission and the U.S. Geological Survey initiated a two-year study to determine the adequacy of current ground-water protection programs and to recommend improvements. In the process of gathering and evaluating hydrogeological data from the Towns of Barnstable and Eastham, the CCAMP Aquifer Assessment Committee developed the papers which are the subject of this publication. These studies formed the technical basis for groundwater resource management decision making.
As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data ...
Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available
Laboratory studies were performed to support field-testing of base injection into the F-Area Seepage Basins groundwater. The general purpose of these experiments is to provide information to guide the test of base injection and to identify potential adverse effects.
Martin Marietta Energy Systems, Inc. (Energy Systems) manages a closed hazardous waste disposal unit, Chestnut Ridge Security Pits (CRSP), in the form of two trenches and several auger-holes, located on top of the eastern portion of Chestnut Ridge at the Department of Energy (DOE) Oak Ridge Y-12 Plant in Tennessee. The groundwater monitoring system for the unit presently consists of a network of upgradient and downgradient monitor wells. To investigate the discharge of groundwater to springs and streams. An initial dye-tracer study was conducted during the driest part of 1990. The dye was detected at some of the monitoring sites, but verification was necessary due to the proximity of some sites to extraneous dye sources. A second dye-tracer was conducted during the wet weather season. The actual test commenced during the first week of February 1992 with a 4-week baseline monitoring period to determine the inherent ...
This document presents a conceptual design for a contingency interim measure (IM) for treatment of the public water supply system at Barnes, Kansas, should this become necessary. The aquifer that serves the public water supply system at Barnes has been affected by trace to low concentrations of carbon tetrachloride and its degradation product, chloroform. Investigations conducted on behalf of the CCC/USDA by Argonne National Laboratory (Argonne 2008a) have demonstrated that groundwater at the Barnes site is contaminated with carbon tetrachloride at concentrations exceeding the Kansas Tier 2 risk-based screening level (RBSL) and the EPA maximum contaminant level (MCL) of 5.0 {micro}g/L for this compound. The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) formerly operated a grain storage facility in Barnes, approximately 800 ft east-southeast of the public water supply wells. Carbon ...
Personnel from Martin Marietta Energy Systems, Inc. (Energy Systems) manage a closed hazardous waste disposal unit the Chestnut Ridge Security Pits (CRSP), located on the crest of Chestnut Ridge near the Y-12 Plant, Oak Ridge, Tennessee. To investigate the discharge of groundwater from CRSP to springs and streams located along the flanks and base of Chestnut Ridge, an initial dye-tracer study was conducted during 1990. A hydraulic connection was inferred to exist between the injection well (GW-178) on Chestnut Ridge and several sites to the east-northeast, east, and southeast of CRSP. A second dye-tracer study was conducted in 1992 to verify the results of the initial test and identify additional discharge points that are active during wet-weather conditions. No definitive evidence for the presence of dye was identified at any of the 35 locations monitored during the second dye study. Although interpretations of the initial dye test suggest a ...
Numerical simulations are used to predict the migration of radionuclides from the disposal units at Material Disposal Area G through the vadose zone and into the main aquifer in support of a radiological performance assessment and composite analysis for the site. The calculations are performed with the finite element code, FEHM. The transport of nuclides through the vadose zone is computed using a three-dimensional model that describes the complex mesa top geology of the site. The model incorporates the positions and inventories of thirty-four disposal pits and four shaft fields located at Area G as well as those of proposed future pits and shafts. Only three nuclides, C-14, Tc-99, and I-129, proved to be of concern for the groundwater pathway over a 10,000-year period. The spatial and temporal flux of these three nuclides from the vadose zone is applied as a source term for the three-dimensional saturated zone model of the main aquifer that ...
Geologic sequestration represents a promising strategy for isolating CO{sub 2} waste streams from the atmosphere. Successful implementation of this approach hinges on our ability to predict the relative effectiveness of subsurface CO{sub 2} migration and sequestration as a function of key target-formation and cap-rock properties, which will enable us to identify optimal sites and evaluate their long-term isolation performance. Quantifying this functional relationship requires a modeling capability that explicitly couples multiphase flow and kinetically controlled geochemical processes. We have developed a unique computational package that meets these criteria, and used it to model CO{sub 2} injection at Statoil's North-Sea Sleipner facility, the world's first saline-aquifer storage site. The package integrates a state-of-the-art reactive transport simulator (NUFT) with supporting geochemical software and databases (SUPCRT92). In our Sleipner ...
The geothermal resources of the Wind River Basin were investigated. Oil-well bottom-hole temperatures, thermal logs of wells, and heat flow data have been interpreted within a framework of geologic and hydrologic constraints. Basic thermal data, which includes the background thermal gradient and the highest recorded temperature and corresponding depth for each basin, is tabulated. Background heat flow in the Wind River Basin is generally insufficient to produce high conductive gradients. Only where hydrologic systems re-distribute heat through mass movement of water will high temperatures occur at shallow depths. Aquifers which may have the confinement and structural characteristics necessary to create such geothermal systems are the Lance/Fort Union, Mesa Verde, Frontier, Muddy, Cloverly, Sundance, Nugget, Park City, Tensleep, Amsden, Madison, Bighorn, and Flathead Formations. Of these the Tensleep Sandstone and Madison ...
During the second half of 1993, the groundwater at the F-Area Seepage Basins (FASB) was monitored in compliance with Module 3, Section C, of South Carolina Hazardous Waste Permit SC1-890-008-989, effective November 2, 1992. The monitoring well network is composed of 87 FSB wells screened in the three hydrostratigraphic units that make up the uppermost aquifer beneath the FASB. A detailed description of the uppermost aquifer is included in the Resource Conservation and Recovery Act Part B post-closure care permit application for the F-Area Hazardous Waste Management Facility submitted to the South Carolina Department of Health and Environmental Control (SCDHEC) in December 1990. Beginning in the first quarter of 1993, the standard for comparison became the SCDHEC Groundwater Protection Standard (GWPS) specified in the approved F-Area Seepage Basins Part B permit. Currently and historically, gross alpha, nitrate, nonvolatile beta, and tritium are ...
Underground injection, compared to other waste disposal methods, is considered to have the advantages of isolating wastes in a confined brine aquifer well below the horizon of human activity and underground sources of drinking water (USDWs). While most of injected wastes move laterally in the injection zone, posing a long-term concern to the human health and environment, a small amount can migrate upward to the upper aquifers, causing a greater threat to the quality of USDWs. Both the dual porosity and the single porosity models were used to investigate the migration of injected wastes through these hydrologic conduits. The results indicate that regional upward migration through an extensive confining formation is a slow process. Nevertheless, injected wastes can move upward rapidly through microannuli and channels in the cement sheath and spread over a distance in the upper aquifer. The wastes can also migrate fast through ...
This paper discusses the potential for geothermal energy use in the central part of Southern Poland, such as the availability of thermal aquifers and the techniques for putting the latter to practical use. The geological and geothermal features of the region are presented within the context of the existence of aquifers containing geothermal resources that could be used in space heating. Also discussed are the three main geological units where thermal waters are known to exist: the Carpathians, the Miechow Trough, and the Silesian-Cracow Monocline. Particularly favourable hydrogeological conditions exist in the Inner Carpathians, in the Podhale Trough, where there is already one geothermal company using geothermal energy, Geotermia Podhalanska S.A. Equally interesting from the geothermal point of view are the areas north of the Cracow-Tarnow line, where, in Mesozoic aquifers, water temperatures range from 20 to 60 {sup o}C. ...
During second quarter 1992, tritium, trichloroethylene, tetrachloroethylene, chloroethene, antimony, 1,1-dichloroethylene, lead, nonvolatile beta, radium-228, thorium-228, or total alpha-emitting radium (radium-226 and radium-228) exceeded the US Environmental Protection Agency Primary Drinking Water Standards (PDWS) in groundwater samples from monitoring wells at the Mixed Waste Management Facility (MWMF) and adjacent facilities. Tritium and trichloroethylene were the most widespread constituents; 55 (48%) of the 115 monitored wells contained elevated tritium activities, and 23 (20%) wells exhibited elevated trichloroethylene concentrations. Sixty-three downgradient wells screened in Aquifer Zone IIB2 (Water Table), Aquifer Zone IIB[sub 2] (Barnwell/McBean), and Aquifer Unit IIA (Congaree) contained concentrations of tritium, trichloroethylene, tetrachloroethylene, chloroethene, antimony, 1,1-dichloroethylene, lead, ...
The purpose of this paper is: (1) conduct HELP model variations in weather data, profile characteristics, and hydraulic conductivities for major rock units; (2) compare and contrast the results of simulations; (3) obtain an estimation of leakage through the landfill from the surface to the aquifer; and (4) evaluate contaminant transport to the aquifer utilizing leakage estimation. The conclusions of this paper are: (1) the HELP model is useful to assess landfill design alternatives or the performance of a pre-existing landfill; (2) model results using site-specific data incorporated into the Weather Generator (Trail 4), varied significantly from generalized runs (Trials 1-3), consequently, models that lack site-specific data should be used cautiously; and (3) data from this study suggest that there will not be significant downward percolation of leachate from the surface of the landfill cap to the aquifer-leachate transport ...
Aerobic chemoheterotrophic bacteria were isolated from surface soils and coastal plain subsurface (including deep aquifer) sediments (depths to 265 m) at a study site near Aiken, S.C., by plating on...Full Text Available
During third quarter 1994, samples from AMB groundwater monitoring wells at the Metallurgical Laboratory Hazardous Waste Management Facility (Met Lab HWMF) were analyzed for selected heavy metals, indicator parameters, radionuclides, volatile organic compounds, and other constituents. Eight parameters exceeded standards during the quarter. As in previous quarters, tetrachloroethylene and trichloroethylene exceeded final Primary Drinking Water Standards (PDWS). Bis(2-ethylhexyl) phthalate exceeded final PDWS in one well. Aluminum, iron, manganese, tin, and total organic halogens exceeded the Savannah River Site (SRS) Flag 2 criteria. Groundwater flow direction and rate in the M-Area Aquifer Zone were similar to previous quarters. Conditions affecting determination of groundwater flow directions and rates in the Upper Lost Lake Aquifer Zone, Lower Lost Lake Aquifer Zone, and the Middle Sand Aquifer Zone ...
In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.
Bahrain's Awali oil field is one of the oldest in the Arabian Gulf region. The recent sharp increase in produced water cut at Awali has resulted in higher oil carry-over in the produced water, which is currently disposed of in an aquifer about 700 ft (210 m) deep. The steps taken by Bahrain Natl. Oil Co. (Banoco) and the problems encountered in improving the quality of effluent are described in this paper.
High nitrate contents (up to 200 mgl) has been observed in wells drilled into fractured aquifers lying beneath layers of weathered and decayed rock in the humid tropics where annual rainfall is over 1,000 mm and where there is no notable pollution. The source of the nitrates is linked mainly with localized deforestation by man.
After a presentation of methods and tools for the basic and extensive characterization of polluted sites and the study of evolution and transfer of current organic pollutants in the ground, the example of the rehabilitation of an old Rhone-Poulenc site (at Chauny, France) polluted with metals and arsenic, is described: soil and aquifer diagnosis, risk analysis and determination of migration schemes
...Chapter 11 Aqueous Solutions Chapter 11 Aqueous Solutions Download the entire chapter (PDF-136k) Drilling to China More water than rivers Saving the aquifer Drying with Xeriscapes Everywhere in the house Rainwater and graywater Creating urban watersheds Wastewater equals ...3851 Powered by Intrcomm Technology's SMC ...
The Rio Grande alluvial floodplain aquifer between El Paso/Juarez and Fort Quitman, Texas has been intensively tilled and irrigated since 1910. Almost since that time, the Rio Grande and its interconnected alluvial aquifer in this stream reach have been affected by excessive salinity problems. Presently, salinity of surface water and groundwater increases from 800 to 2000 mg/L total dissolved solids (TDS) near El Paso, Texas to 2500 to 5500 mg/L TDS near Fort Quitman, Texas, approximately 115 km downstream. Chloride (Cl) and Chloride/Bromide (Cl/Br) ratios increase downstream, with a marked increase in salinity beginning about 45 km below El Paso. Groundwater sampling in an intensively investigated reach of the floodplain aquifer, extending from 35 to 60 km below El Paso identified two distinct water types. The first water type (17 samples) is a relatively dilute groundwater containing 1000 to 2000 mg/L TDS, 250 to 600 ...
Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On the Environmental Front the main problems are water-logging ...
The International Atomic Energy Agency (IAEA) started the Coordinated Research Program entitled ```The Safety Assessment of Near-Surface Radioactive Waste Disposal Facilities.`` The program is aimed at improving the confidence in the modeling results for safety assessments of waste disposal facilities. The program has been given the acronym NSARS (Near-Surface Radioactive Waste Disposal Safety Assessment Reliability Study) for ease of reference. The purpose of this report is to present the ORNL modeling results for the first test case (i.e., Test Case 1) of the IAEA NSARS program. Test Case 1 is based on near-surface disposal of radionuclides that are subsequently leached to a saturated-sand aquifer. Exposure to radionuclides results from use of a well screened in the aquifer and from intrusion into the repository. Two repository concepts were defined in Test Case 1: a simple earth trench and an engineered vault.
The mobility of metals in ground water is an important consideration for evaluating remedial options at the Asarco smelter site. Tacoma, Washington. One factor in assessing metal mobility is the degree of secondary mineralization in a slag-fill aquifer extending into the intertidal zone along the Puget Sound shoreline. Samples of aquifer material were collected for mineralogical analysis from borehole MW-206 at five-foot intervals within the slag fill from 5 to 25 feet below the ground surface, and in the underlying marine sand and gravel at 27 feet. Grab samples of slag fragments with visually apparent secondary minerals were also collected at five intermediate depths between 12 and 19 feet. Samples were analyzed by a variety of techniques including hydride generation/atomic absorption for arsenic concentration, scanning electron microscopy/electron microprobe for mineralogical texture and microanalysis, powder x-ray diffraction for mineral ...
In this study, adjoint sensitivity theory is developed for equations of two-dimensional steady-state flow in a confined aquifer. Both the primary flow equation and the adjoint sensitivity equation are solved using the Galerkin finite element method. The developed computer code is used to investigate the regional flow parameters of the Leadville Formation of the Paradox Basin in Utah and the Wolcamp carbonate/sandstone aquifer of the Palo Duro Basin in the Texas Panhandle. Two performance measures are evaluated, local heads and velocity in the vicinity of potential high-level nuclear waste repositories. The results illustrate the sensitivity of calculated local heads to the boundary conditions. Local velocity-related performance measures are more sensitive to hydraulic conductivities. The uncertainty in the performance measure is a function of the parameter sensitivity, parameter variance and the correlation between parameters. Given a parameter ...
In the United States, economic growth increasingly requires that greater volumes of freshwater be made available for new users, yet supplies of freshwater are already allocated to existing users. Currently, water for new users is made available through re-allocation of xisting water supplies-for example, by cities purchasing agricultural water rights. Water may also be made available through conservation efforts and, in some locales, through the development of ''new'' water from non-traditional sources such as the oceans, deep aquifer rackish groundwater, and water reuse.
This report provides analytical results for groundwater collected during four characterization-sampling rounds conducted at well R-22 from March 2001 through March 2002. Characterization well R-22 was sampled from March 6 through 13, 2001; June 19 through 26, 2001; November 30 through December 10, 2001; and February 27 through March 7, 2002. The goal of the characterization efforts was to assess the hydrochemistry and to determine whether or not contaminants are present in the regional aquifer in the vicinity of the well. A geochemical evaluation of the analytical results for the well is also presented in this report.
Microorganisms associated with fractured basalt core were compared to those suspended in groundwater pumped from the same well in the eastern Snake River Plain Aquifer (Idaho, USA). Two wells influenced to different degrees by a mixed-waste plume in the fractured basalt aquifer were examined. In one well, an array of dialysis cells filled with either deionized water or crushed basalt was equilibrated to compare the microorganisms collected in this fashion with those from core and groundwater samples collected in a traditional manner from the same well. Analyses were performed to characterize these samples and to provide a basis for comparison. These included total cell counts by microscopy; total biomass by phospholipid fatty acid analysis; enumerations of viable aerobic heterotrophs, groups of putative aerobic co-metabolic TCE-degraders and aerobic H2-oxidizing bacteria; mineralization of 14C- labeled acetate; and enrichments for dissimilatory ...
This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) To prepare the project's final report. This report covers activities ...
In early 2004, the U.S. Department of Energy (DOE) Richland and Fluor Hanford requested technical assistance from the DOE Headquarters EM-23 Technical Assistance Program to provide a team of technical experts to develop recommendations for mending the In Situ Redox Manipulation (ISRM) Barrier in the 100-D Area of the Hanford Site in Washington State. To accommodate this request, EM-23 provided support to convene a group of technical experts from industry, a national laboratory, and a DOE site to participate in a 2 1/2-day workshop with the objective of identifying and recommending options to enhance the performance of the 100-D Area reactive barrier and of a planned extension to the northeast. This report provides written documentation of the team's findings and recommendations. In 1995, a plume of dissolved hexavalent chromium [Cr(VI)], which resulted from operation of the D/DR Reactors at the Hanford site, was discovered along the Columbia River shoreline and in the 100-D ...
This study presents monthly estimates of groundwater anomalies in a large river basin dominated by extensive floodplains, the Negro River Basin, based on the synergistic analysis using multisatellite observations and hydrological models. For the period 2003-2004, changes in water stored in the aquifer is isolated from the total water storage measured by GRACE by removing contributions of both the surface reservoir, derived from satellite imagery and radar altimetry, and the root zone reservoir simulated by WGHM and LaD hydrological models. The groundwater anomalies show a realistic spatial pattern compared with the hydrogeological map of the basin, and similar temporal variations to local in situ groundwater observations and altimetry-derived level height measurements. Results highlight th...
Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...
The site characterization of Yucca Mountain, NV as a potential high level nuclear waste repository includes study of the surficial deposits as a record of the paleoenvironmental history of the Yucca Mountain region. An important aspect of this history is an understanding of the evolution of paleogeography leading to establishment of the present drainage pattern. Establishment of drainage basin evolution is needed before geomorphic response to paleoclimate and tectonics can be assessed, because a major change in drainage basin geometry can predominantly affect the sedimentary record. Because alluvial aquifers are significant to regional hydrology, a major change in surface drainage resulting in buried alluvium could have hydrogeologic significance. In this paper, we report on geologic evidence for a major modification in surface drainage pattern in the Yucca Mountain region, resulting in the probable establishment of the Fortymile Wash drainage basin by latest ...
SPEOS takes advantage of a geological situation which apparently does not occur much in Switzerland. The SPEOS pilot installation, which was erected in 1982, is designed for the supply of heat for about 500 persons. In the course of 10 cycles, the possibilities and limits of the seasonal heat storage were displayed. It was demonstrated that large quantities of heat with temperatures of up to 75 C can be stored in an aquifer. The behaviour of such a storage can be predicted with sufficient accuracy with mathematical models. (author) 12 refs.
In France, groundwater usage represents 40 per cent of volumetric use, outside of thermal power plants. Groundwater represents 60 per cent of domestic and public use, 40 per cent in the industrial sector, and is increasing in the agricultural sector where it accounts for 20 per cent. Groundwater withdrawal in France has slightly increased over the last twenty years and benefited the agricultural sector. Availability throughout the territory, the consistency of resupply and natural quality has rendered groundwater a prevailing source for drinking water. Water protection and management is important and led to the adoption of legislative and regulatory measures. The Mining Code (Code minier) allows for exploitation of underground resources starting at 10 metres. The Rural Code (Code rural) mandates the declaration of public utility for water collection for the public. Protection areas are to be provided under the Public Health Code (Code de sante publique). Proper permits and ...
Norway is privileged with extensive resources of natural gas, oil and hydropower. Location of gas fired combined cycle (CC) power plants in Norway offers advantages due to the availability of natural gas from the Norwegian continental shelf and fairly low ambient temperatures, giving high fuel-to-electricity conversion efficiency. The continental shelf provides large storage capacity for CO{sub 2} in deep saline aquifers and in drained gas fields. In this paper the results of extensive work on CO{sub 2} capture carried out during the last years by Statoil in co-operation with several engineering contractors, are presented. The goal has been to develop a commercially viable concept for a combined cycle power plant including CO{sub 2} capture and sequestration. The main concept is based on CO{sub 2} capture from exhaust gas from a combined cycle power plant, using absorption by amine (MEA) solutions. The CO{sub 2} is compressed, transported by pipeline and stored in ...
The uncertainty associated with the sorption coefficient, or K{sub d} value, is one of the key uncertainties in estimating risk associated with burying low-level nuclear waste in the subsurface. The objective of this study was to measure >648 K{sub d} values and provide a measure of the range and distribution (normal or log-normal) of radionuclide K{sub d} values appropriate for the E-Area disposal site, within the Savannah River Site, near Aiken South Carolina. The 95% confidence level for the mean K{sub d} was twice the mean in the Aquifer Zone (18-30.5 m depth), equal to the mean for the Upper Vadose Zone (3.3-10 m depth), and half the mean for the Lower Vadose Zone (3.10-18 m depth). The distribution of K{sub d} values was log normal in the Upper Vadose Zone and Aquifer Zone, and normal in the Lower Vadose Zone. To our knowledge, this is the first report of natural radionuclide Kd variability in the literature. Using ranges and ...
The chemical composition and evolution of formation waters associated with gas production in the Palm Valley field, Northern Territory, has important implications for reservoir management, saline water disposal, and gas reserve calculations. Historically, the occurrence of saline formation water in gas fields has been the subject of considerable debate. A better understanding of the origin, chemical evolution and movement of the formation water at Palm Valley has important implications for future reservoir management, disposal of highly saline water and accurate gas reserves estimation. Major and trace element abundance data suggest that a significant component of the highly saline water from Palm Valley has characteristics that may have been derived from a modified evaporated seawater source such as an evaporite horizon. The most dilute waters probably represent condensate and the variation in the chemistry of the intermediate waters suggests they were derived from a mixture of the ...
The environmental impacts of uranium mining and milling activities are of great concern in many countries for the last three decades. These impacts range from the creation of massive stockpiles of radioactive and toxic waste rock and sand-like tailings to serious contamination of surface and groundwater with radioactive and toxic pollutants, and releases of conventional, toxic and radioactive air pollutants. Uranium mining is also associated with high concentrations of highly toxic heavy metals, which are a major source of surface and groundwater contamination. Depending upon the hydraulic properties of the fractures involved, contaminated ground water may be transported many miles from its point of origin before feeding into an aquifer. Tailings pond may contaminate the groundwater regime by continuous seepage and leaching of radionuclides and other toxic metals due to interaction of rain water through the tailings ponds. The uranium milling and tailings pond ...
Full text: Groundwater in rural agricultural area of South Korea is an important source of drinking and agricultural water. The study area is located in mid-western coastal parts and has fractured bedrock aquifers whose lithologies are composed of Jurassic granites, Paleozoic sedimentary rocks, Precambrian schists and gneiss. Bedrock groundwater was slightly alkaline and had electrical conductivity of 40 to 1570 #mu#S/cm with median values of 322 #mu#S/cm. Water types based on major ions showed that Ca-HCO_3 and Ca-CI types are dominant and Na-HCO_3 and Na-CI types are minor. Intense agricultural activities resulted in significant nitrate contamination of groundwater. 22% and 40% of wells have exceeded drinking water standards (DWS) for bedrock and shallow wells, respectively. In coastal areas, slightly saline groundwater is observed for both bedrock and shallow wells. Groundwater in granitic rocks may have higher concentrations of Rn, U and F. Most wells had ...
SummaryIntended Outputs: Identification and evaluation, using participatory approaches, of demand management options:*Technical*Allocative and market based*Impact on target beneficiariesSupporting measures required when introducing water demand management options above:*Extension services & training*Water licences/rights*Institutional changes*Legal measures and regulation*Education*Support in diversifying to less water demanding activities*S [continued...]ObjectivesIdentification of the most appropriate demand management strategies for ground water abstraction, where aquifiers are being over-exploited, ensuring sustainable livelihoods of the vulnerable and poor are safeguarded. Poverty reduction strategies for areas where groundwater is being over-exploited.DescriptionProject Background: Groundwater is the principal source of both irrigation and domestic water supplies in many arid and semi-arid countries. However, many of these countries are already consuming more water than is ...
Expressions for the spatial moments and macrodispersion tensor for sorbing solutes in heterogeneous formations were presented using a probabilistic model of a fluid residence time coupled with the particle position analysis. The fluid residence time was defined as a fraction of the actual time during which the particle stayed in the mobile fluid phase of the aquifer. The fluid residence time is a random variable whose variability comes as a result of the non-equilibrium sorption properties. The sorbing solute was assumed to be governed with first-order linear kinetics. The closed-form expressions were based on the stationarity in the kinetic process and on the first-order approximation in the hydraulic conductivity field and in the fluid residence time. The non-equilibrium effects were presented as a function of the spatial variability in hydraulic conductivity and temporal variability in the fluid residence time. The importance of the non-equilibrium processes in ...
The papers presented at the symposium had covered three general areas in which isotopes could have been beneficially used. these areas are: -Water use and water use efficiency studies. -Ground water investigations -Water problems in the arab countries. The individual papers had dealt with these subjects: -Hydrological research in the arab countries by use of radioisotopes. -The perspectives of use of radioisotopes in hydrological studies in Syria. -Water use efficiency and sub-soil water studies. -Sea water inclusion in a coast el aquifers in Lebanon. -Irrigation requirements of crops in Lebanon as determined by a Neutron probe with reference to other methods. -The use of the neutron moisture meter and other methods of the determination of the evapotranspiration of maize. -Ground water investigations, dating and nuclear methods applied to hydrology. -Ground water investigation in Wa di El-Nat run, U.A.R. -Velocity distribution along the pumped well using ...
Due to severe drought conditions in Pakistan over the past several years, most of the areas are facing extinction of its potable water reserves and inadequate replenishment of groundwater aquifers. Due to over exploitation, the groundwater flow dynamics is changing and water quality is degrading due to induced infiltration from polluted surface sources. Isotope hydrology is relatively a new discipline having great potential for studying various water-related problems. RIAD, PINSTECH has established analytical facilities for commonly used environmental isotopes and applied to investigate various hydrological problems. This paper briefly describes practical examples on recharge mechanism and dating of groundwater in Lahore and Ziarat areas using isotopes like deuterium (/sup 2/H), Oxygen-18 (/sup 18/O), Tritium (/sup 3/H) and CFCs in water. In Lahore, the areas having different contribution of the river Ravi in groundwater recharge have been marked and on the basis ...
Soil contamination by liquid organic pollutants represents a serious threat to phreatic ground water. These organic liquids get into the ground and migrate through the porous medium until they finally reach the aquifer. After a critical study of the literature, we listed various existing multiple displacements under three-phase conditions of a disconnected polluting phase that may or not spread over water. The aim of this thesis is to model (at pore scale level) and integrate in the pore network model the various flows that occur when three phases (gas, pollutant and air) are present in a porous medium. The porous medium is supposed completely water-wet. The polluting phase may be connected or not, and the spreading coefficient of the pollutant over water may either be positive or negative. The goal of our study is to obtain macroscopic parameters such as relative permeabilities and capillary pressure. These parameters can be then incorporated in a larger-scale ...
A series of experiments involving high explosives and radioactive materials were conducted at Los Alamos, New Mexico, primarily to understand certain safety aspects of operational nuclear weapons. The experiments were conducted underground in large diameter holes as deep as 120 ft. The location was selected because it had geologic and hydrologic characteristics that assured complete containment of the experiments and precluded any possible contamination of groundwater. Important features verified by the USGS included the absence of any recharge and about 1200 feet of dry rock above the groundwater aquifer. Residual materials dispersed by detonation of the high explosives remain at the bottom of the experimental holes. The materials of significance from an environmental standpoint include about 40 kg of plutonium, 93 kg of enriched uranium, at least 82 kg of depleted uranium, 13 kg of beryllium, and an undetermined amount of lead. Environmental monitoring has been ...
One of the principal problems confronting the remediation of Bear Creek Valley is the cleanup of contaminated groundwater. The S-3 Site is one of the locations in the valley where groundwater is most contaminated, and contamination from the S-3 Site has also caused extensive contamination of downgradient groundwater. This groundwater plume, therefore, has a high priority in the Bear Creek Valley remedial process. Pumping and treating groundwater was identified early in the feasibility study as a likely remedial alternative for the S-3 Site groundwater plume. The hydrology and geochemistry of the plume are extremely complex. There is a high degree of uncertainty in the current understanding of how the aquifer will react physically and chemically to pumping, making evaluation of a pump-and-treat alternative impractical at the present time. Before a pump-and-treat alternative can be evaluated, its technical practicability, effectiveness, and projected cost must be ...
This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) including calendar year 2008 results. Each of the three Pilot Wells was sampled on March 11, 2008, and September 10, 2008. These wells were sampled for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2008 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater Monitoring Program and ...
This report is a compilation of the groundwater sampling results from the Area 5 Radioactive Waste Management Site (RWMS) for calendar year 2006. Pilot wells UE5PW-1, UE5PW-2, and UE5PW-3 were sampled in April and October 2006 for the following indicators of contamination: pH, specific conductance, total organic carbon, total organic halides, and tritium. Indicators of general water chemistry (cations and anions) were also monitored. Results from all samples collected in 2006 were within the limits established by agreement with the Nevada Division of Environmental Protection for each analyte. These data indicate that there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS. There were no significant changes in measured groundwater parameters compared to previous years. Other information in the report includes an updated Cumulative Chronology for the Area 5 RWMS Groundwater Monitoring Program and a brief description of the site hydrogeology.
Hydrologic information is essential for environmental efforts at Los Alamos National Laboratory. Testing at new characterization wells being drilled to the regional aquifer (''R wells'') to improve the conceptual hydrogeologic model of the Pajarito Plateau is providing such information. Drilling has been by air-rotary casing-advance or open-hole methods. Most wells are completed with multiple screens. After their construction, wells were rigorously developed by wire-brushing, bailing, followed by surging, swabbing, or jetting, and finally by pumping. These methods are effective based on field-parameter measurements and comparison of results of hydrologic testing at well R-31 before and after complete well development. We conducted field tests on various zones of saturation penetrated by the R wells to collect data needed for determining hydraulic properties. This document provides details of the design and execution of testing as ...
Temperature data to depths of a few hundred meters were obtained from 29 wells in northeastern Arizona; 12 in the region surrounding the San Francisco Volcanic Field, 8 in the Black Mesa area, and 9 in the south-central Colorado Plateau which includes the White Mountains. Although there was evidence for local hydrologic disturbances in many temperature profiles, most wells provided an estimate of the conductive thermal gradient at the site. A few thermal conductivities were measured and were combined with published regional averages for the north-central part of the Colorado Plateau to produce crude estimates of regional heat flux. None of the wells was accessible below the regional aquifers. To these depths, heat flow in the area of the San Francisco Volcanic Field appears to be controlled primarily by regional lateral water movement having a significant downward vertical component of velocity. The mean heat flow of 27 +- 5 mWm/sup -2/ is only a third to a quarter ...
A performance assessment analysis was completed for the 200 East Area Low-Level Burial Grounds (LLBG) to satisfy compliance requirements in DOE Order 5820.2A. In the analysis, scenarios of radionuclide release from the 200 East Area Low-Level waste facility was evaluated. The analysis focused on two primary scenarios leading to exposure. The first was inadvertent intrusion. In this scenario, it was assumed that institutional control of the site and knowledge of the disposal facility has been lost. Waste is subsequently exhumed and dose from exposure is received. The second scenario was groundwater contamination.In this scenario, radionuclides are leached from the waste by infiltrating precipitation and transported through the soil column to the underlying unconfined aquifer. The contaminated water is pumped from a well 100 m downstream and consumed,causing dose. Estimates of potential contamination of the surrounding environment were developed and the associated ...
A chronology for Paleocene strata of the Hinton area of west-central Alberta was developed from the integration of a magnetostratigraphic and palynostratigraphic study of the upper Coalspur and middle to upper Paskapoo strata in the Coal Valley to Obed Mountain area. The study resulted in the compilation of a complete section of 1100 m of strata with a maximum sediment accumulation rate of 250 m/m.y. Four new informal biostratigraphic units were used to highlight stratigraphically useful bioevents not previously recognized in existing zonations. These strata range in age from magnetochron 29r to 24r and palynozones Wodehouseia spinata Zone, Aquilapollenites reticulatus Subzone through the Pistillipollenite mcgregorii Zone. The 3 intervals with the most rapid changes in the palynoflora were the earliest Paleocene; the transition from the early to middle Paleocene; and in the late Paleocene. Each coincides with critical times in basin development, notably the initiation of regionally ...
It has been understood that production of hydrogen from fossil and carbonaceous fuels with reduced CO{sub 2} emission to the atmosphere is key to the production of hydrogen-rich fuels for mitigating the CO{sub 2} greenhouse gas climate change problem. The conventional methods of hydrogen production from fossil fuels (coal, oil, gas and biomass) include steam reforming and water gas shift mainly of natural gas (SRM). In order to suppress CO{sub 2} emission from the steam reforming process, CO{sub 2} must be concentrated and sequestered either in or under the ocean or underground (in aquifers, or depleted oil or gas wells). Up to about 40% of the energy is lost in this process. An alternative process is the pyrolysis or the thermal decomposition of methane, natural gas (TDM) to hydrogen and carbon. The carbon can either be sequestered or sold on the market as a materials commodity or used as a fuel at a later date under less severe CO{sub 2} restraints. The energy ...
The risk to human health from fragments of depleted uranium (DU) at Jefferson Proving Ground (JPG) was estimated using two types of ecosystem pathway models. A steady-state, model of the JPG area was developed to examine the effects of DU in soils, water, and vegetation on deer that were hunted and consumed by humans. The RESRAD code was also used to estimate the effects of farming the impact area and consuming the products derived from the farm. The steady-state model showed that minimal doses to humans are expected from consumption of deer that inhabit the impact area. Median values for doses to humans range from about 1 mrem ({plus_minus}2.4) to 0.04 mrem ({plus_minus}0.13) and translate to less than 1 {times} 10{sup {minus}6} detriments (excess cancers) in the population. Monte Carlo simulation of the steady-state model was used to derive the probability distributions from which the median values were drawn. Sensitivity analyses of the steady-state model showed that the amount of ...
A general criterion has been suggested for deep geological repositories containing spent fuel - the repositories should impose no greater radiological risk than due to naturally occurring uranium deposits. The following analysis investigates the rationale of that suggestion and determines whether current expectations of spent-fuel repository performance are consistent with such a criterion. In this study, reference spent-fuel repositories were compared to natural uranium-ore deposits. Comparisons were based on intrinsic characteristics, such as radionuclide inventory, depth, proximity to aquifers, and regional distribution, and actual and potential radiological consequences that are now occurring from some ore deposits and that may eventually occur from repositories and other ore deposits. The comparison results show that the repositories are quite comparable to the natural ore deposits and, in some cases, present less radiological hazard than their natural ...
A study was conducted to determine the feasibility and the opportunity of photochemical pretreatment on the biodegradation and detoxification of Methyl Tert Butyl Ether (MTBE), Ethyl Tert Butyl Ether (ETBE) and Tert Amyl Methyl Ether (TAME), the most common oxygenates used as octane enhancers in unleaded gasoline. The production, storage, uses and disposal of oxygenates result in an unknown amount of groundwater pollution. Because of their high solubility, MTBE, ETBE and TAME are detected in large portions in saturated zones of aquifers. The biodegradation of these oxygenates is difficult and slow, and information regarding their biodegradability is scarce. Photo-decomposition of oxidants under appropriate UV radiation has been shown to be very effective because the hydroxyl radicals produced possess high oxidation potential. In this study, the H{sub 2}O{sub 2}/UV process was used to generate hydroxyl radicals. Maximal oxygenates transformation was obtained in a ...
A study was conducted to determine the feasibility and the opportunity of photochemical pretreatment on the biodegradation and detoxification of Methyl Tert Butyl Ether (MTBE), Ethyl Tert Butyl Ether (ETBE) and Tert Amyl Methyl Ether (TAME), the most common oxygenates used as octane enhancers in unleaded gasoline. The production, storage, uses and disposal of oxygenates result in an unknown amount of groundwater pollution. Because of their high solubility, MTBE, ETBE and TAME are detected in large portions in saturated zones of aquifers. The biodegradation of these oxygenates is difficult and slow, and information regarding their biodegradability is scarce. Photo-decomposition of oxidants under appropriate UV radiation has been shown to be very effective because the hydroxyl radicals produced possess high oxidation potential. In this study, the H_2O_2/UV process was used to generate hydroxyl radicals. Maximal oxygenates transformation was obtained in a few minutes. ...
This report is a compilation of the calendar year 2003 groundwater sampling results from the Area 5 Radioactive Waste Management Site, Nevada Test Site. Wells Ue5PW-1, Ue5PW-2, and Ue5PW-3 were sampled semi-annually for the required analytes: pH, specific conductance, total organic carbon (TOC), total organic halides (TOX), tritium, and major cations/anions. Results from all samples collected in 2003 were within established criteria. These data indicate that there has been no measurable impact to the uppermost aquifer from the Resource Conservation and Recovery Act (RCRA) regulated unit within the Area 5 Radioactive Waste Management Site and confirm that any previous detections of TOC and TOX were false positives. Contamination indicator data are presented in control chart and tabular form with investigation levels indicated. Gross water chemistry data are presented in graphical and tabular form. There were no major changes noted in the monitored groundwater ...
This paper presents some basic elements regarding the domain of the collaborative systems, a domain of maximum actuality and also the multiagent systems, developed as a result of a sound study on the one-agent systems.
Environmental monitoring data were collected at and around the Area 3 and Area 5 Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site. These data are associated with radiation exposure, air, groundwater, meteorology, vadose zone, subsidence, and biota. This report summarizes the 2006 environmental data to provide an overall evaluation of RWMS performance and to support environmental compliance and performance assessment (PA) activities. Some of these data (e.g., radiation exposure, air, and groundwater) are presented in other reports (U.S. Department of Energy, 2006; Warren and Grossman, 2007; National Security Technologies, LLC, 2007). Direct radiation monitoring data indicate that exposure levels around the RWMSs are at or below background levels. Air monitoring data at the Area 3 and Area 5 RWMSs indicate that tritium concentrations are slightly above background levels. There is no detectable man-made radioactivity by gamma spectroscopy, and concentrations of americium ...
An outline of the instrumentation and control systems associated with fuelling machines is given. The control systems such as hydraulic system, oil hydraulic system, electric control system and the remote control systems have been discussed in detail. The difference between RAPP and MAPP fuel handling control systems has been explained. A computer based system for the Narora fuel handling control system is also discussed. (S.K.K.).
The aim of this paper is to survey the potential of knowledge systems for the management and modelling of energy systems. The paper starts with a short introduction to knowledge systems. The essence of knowledge systems is summarized and described in terms of modelling. Additionally the application of knowledge systems is compared with the use of conventional software on the one hand and human reasoning on the other. Next, research topics which are important in connection with technological applications of knowledge systems are reviewed. This paper follows with a review of knowledge system applications in the field of energy systems and ends with conclusions on the state of the art and required research and development.
The groundwater flow and transport model of the Faultless underground nuclear test conducted at the Central Nevada Test Area (CNTA) was accepted by the state regulator and the environmental remediation efforts at the site have progressed to the stages of model validation and long-term monitoring design. This report discusses the long-term monitoring strategy developed for CNTA. Subsurface monitoring is an expensive and time-consuming process, and the design approach should be based on a solid foundation. As such, a thorough literature review of monitoring network design is first presented. Monitoring well networks can be designed for a number of objectives including aquifer characterization, parameter estimation, compliance monitoring, detection monitoring, ambient monitoring, and research monitoring, to name a few. Design methodologies also range from simple hydrogeologic intuition-based tools to sophisticated statistical- and optimization-based tools. When ...
According to the present concept, the low and intermediate level wastes generated during the Cernavoda NPP operation will be disposed in a near surface repository. The Saligny site, placed in the NPP protected area, has been proposed for their disposal. Geologically, the main components of this site are the quaternary loess, the Precambrian and Pre-quaternary clays, the Eocene and Barremian limestone. Hydrologically, the site can be divided into a vadose zone down to 45-50 m and three distinct aquifers, two of them in the limestone beds and the third in the lenses of sand and limestone existing in the pre-quaternary clay layer. A large research program for site characterization was initiated in 1996. At present, the site characteristics requested for safety analysis have been experimentally measured on soil samples or calculated by different computer programs. Hundreds of experimental values of the density, porosity, hydraulic conductivity, soil-water retention, ...
This report presents the results of a study of the Japanese MLU magnetic-levitation (maglev) system. The development of the MLU system is reviewed, and the dynamic circuit model then is introduced and applied to the figure-eight-shaped null-flux coil suspension system. Three different types of figure-eight-shaped null-flux suspension systems are discussed in detail: (1) the figure-eight-shaped null-flux coil suspension system without cross-connection; (2) the combined suspension and guidance system; and (3) the combined propulsion, levitation, and guidance system. The electrodynamic-suspension maglev systems developed in Japan seem to be very promising and could result in a commercial application in the near future.
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
The activities and the policy in the Netherlands regarding the development of the title systems since 1990 are briefly outlined, focusing on the use of PV-systems in buildings. 5 figs., 1 tab.
Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...
The development of online communication systems related to prevention, decision making, and coping with cancer has outpaced theoretical attention to the attributes that appeal to system...Full Text Available
...Systems by IPEX Enfield electrofusion acid waste systems give you the proven corrosion resistance of polypropylene, along with our patented, state-of-the-art electrofusion system....
This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the best choices for EV HVAC. These are, vapor compression, ice ...
The problem on the ratio between the instability of physical systems and tachyons is discussed. It is shown that the tachyons participation in the real physical process of the system rearranging does not contradict any principles. It is noted that the tachyons constitute the most significant element of the systems, identifying the instability relative to the phase transition into the stable state.
Contact scanner system in Wolsung NPP(model ESE-1565) is an early '70 equipment, so most of components are obsolete. To make it 100% compatible, PCBs for this system is the main object of the study. Most of components used in the system are not available ...
This paper details the ongoing collaboration between the U.S. EPA and the U.S. Army Corps of Engineers in the development of complementary micro-computer based cost estimating systems for hazardous waste remediations. he U.S. EPA system, "Remedial Action Cost Estimating System" (...
... 2010-10-01 false Cost estimating system requirements. 252...Clauses 252.215-7002 Cost estimating system requirements. As...use the following clause: Cost Estimating System Requirements (DEC...
... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...
... POVs) overseas when space was available. ... information management system launched in 2004. ... Personally Procured Transportation (PPT) system ...
The waste monitoring system in use at Los Alamos National Laboratory`s Plutonium Facility, TA-55, is a computer-based system that proves real-time information on industrial effluents. Remote computers monitor discharge events and data moves from one system to another via a local area network. This report describes the history, system design, summary, instrumentation list, displays, trending screens, and layout of the waste monitoring system.
This paper is concerned with the application of a new fuzzy inference method to the design of fuzzy power system stabilizer. Based on Truth-Value-Flow-Inference (TVFI), a fuzzy logic controlled power system stabilizer is proposed to enhance the stability of power system with weak or negative damping. The design of the proposed fuzzy power system stabilizer is presented. Numerical simulation results are presented and compared with two other kinds of fuzzy power system stabilizers. (author)
A micro-computer based fuzzy logic power system stabilizer is applied to a micro-machine system to investigate its efficiency in real time control. The stabilizing signal is determined by using measured speed or real power signals at every sampling time to damp the system oscillations. The results show the proposed stabilizer improves the system damping effectively subject to various types of disturbances.
A mathematical model of the multi machine electric power system to analyse its dynamics has been worked out. The effectivity of the power system stabilizer developed in the one machine system has been tested by means of this model. The influence of the arrangement of the stabilizers on the stability of the electric power system has also been investigated. High damping of electromechanical transient processes has been achieved. 7 refs., 1 tab., 5 figs.
The paper presents a sequential procedure for coordinated stabilization of a multimachine power system with arbitrary complexity of the system model. The most effective machine to be equipped with a power system stabilizer is identified using eigenvalue analysis. The selection is based on the sensitivity of critical eigenvalues to increases in the coefficient of a damping term which is inserted in each equation of motion, in succession. The method is applied to a three-machine system and simulation studies show appreciable improvements in the small disturbance stability of the system.
A heuristic algorithm that employs fuzzy logic is proposed to the power system transmission expansion planning problem. The algorithm is based on the divide to conquer strategy, which is controlled by the fuzzy system. The algorithm provides high quality solutions with the use of fuzzy decision making, which is based on nondeterministic criteria to guide the search. The fuzzy system provides a self-adjusting mechanism that eliminates the manual adjustment of parameters to each system being solved. (author)
An integrated voltage regulator and power system stabilizer based on one step ahead prediction is presented. The fixed parameter predictive control scheme is shown capable of providing consistently good voltage response and contribution to system damping over a wide range of operating conditions and system configuration. This is in contrast to the case with conventional automatic voltage regulator and power system stabilizer where performance varies widely with the operating situation and can even cause system instability. (author)
The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a ...
Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade ...
Inputs on radiological conditions forms the basis of implementation of effective exposure control to plant personnel in nuclear power station. Radiation monitoring system provides this input to the plant operator as well as to health physics group. Several design modifications have been incorporated in the Radiation Monitoring System at Tarapur Atomic Power Station (TAPS 3 and 4) over the similar systems at Kakrapar Atomic Power Station (KAPS) and Kaiga Generating Station (KGS). The radiological monitoring systems installed at TAPS unit 3 and 4 includes on line Radiation Data Acquisition System (RADAS), Emergency sampling system, effluent monitoring system and environmental monitoring system. The design changes and the versatile use of these systems are presented in this paper. (author)
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
This paper presents case studies of economic feasibility of solar photovoltaic systems using the software AVES-F (Analysis of Economic Feasibility of Photovoltaic Systems), developed by the authors, considering cases of stand-alone and grid-connected systems. The software takes into account several factors that can influence the economic feasibility of these kind of systems, like load to be supplied, distance to the grid, the use regime of the system, applied subsidies and others. The main goal of this paper is to analyze some of these factors and to observe how they can affect the economics of PV systems for electricity generation. (authors)
The notion of hardened systems can be found in several applications (nuclear power plants, alarm systems, research installations..). Their development correspond to the functional necessity to take into account a specific radiative environment. The starting point of each hardening study is the definition of the radiative environmental constraints representative of the application. In addition to these external constraints, the specific functional characteristics of each system are considered: control or interface systems in nuclear industry, in-board control systems, remote handling systems, etc. This paper summarizes the methodology followed according to the experience gained in previous studies and anticipating the future needs. (J.S.). 6 refs., 5 figs.
The term biological motion is often used by researchers studying the patterns of movement generated by living forms and in sports. We studied a pattern recognition system of motion in sport using biological motion data. Biological motion data are acquired using a 3D motion capture system. However, 3D motion capture systems are very expensive. In this article, a biological motion capture system was built using acceleration sensors. Our proposed system uses the technique of Gaussian fitting and regression analysis. We tested our proposed system in pattern recognition of outdoor tennis and its evaluations.
A new power system stabilizer (PSS) design method for single-machine infinite-bus systems is developed. This design method not only assigns the poles corresponding to the electro-mechanical oscillation modes in the system, but also located other system poles in suitable places in the s-plane. The design procedure is used first to translate a PSS design problem to an equivalent constant output feedback controller design problem for a single-input multi-output (SIMO) system. Then, a new algorithm developed in this paper is applied to design a constant output feedback controller to achieve the desired closed-loop system pole locations. Finally, the controller gains are transferred back to the parameters in the PSS. The extension of the method to multi-machine power systems is also illustrated. (Author).
This guide is intended to provide the necessary guidance to successfully manage the NAVMED Navy Occupational Health Information Management System (NOHIMS) at NAVMED sites and the NAVSEA Occupational Safety and Health Record Keeping System (OSHRKS) at NAVSEA sites. Outlines procedures to manage system operations, procedures to resolve hardware, software and communications problems, and procedures outside the realm of system operations that are required for a successful system. This guide is intended for the System and Functional Managers use. The System Manager is the individual designated to provide overall ADP management to the entire local configuration. Usually responsible for file backup, daily operations of the CPU, security, supplies, equipment, operating software and technical ADP guidance to the local functional users.
Fuji Electric has realized highly reliable and functional control systems by the dispersion type control system FOCUS, which uses the controller (ICS-2000) enjoying good reputation in controlling industrial plants for a long time and a personal computer with high windows operability, the former for controlling and the latter for MHI responsible for monitoring. The smelting process in a steel-making plant needs a highly reliable system for advanced control to ensure continuous operation. Fuji Electric delivered the FOCUS system to Kubota in 1998, as the smelting furnace instrumentation/control system for the cupola furnace. The system has been in service smoothly. Moreover, a total of four control systems have been delivered, 2 for steel-making furnaces and the other 2 for continuous casting. (NEDO)
The Reliability Data Management System (RDMS) for safety systems of PHWR type plants has been developed and utilized in the reliability analysis of the special safety systems of Wolsong Unit 1 with plant overhaul period lengthened. The RDMS is developed for the periodic efficient reliability analysis of the safety systems of Wolsong Unit 1. In addition, this system provides the function of analyzing the effects on safety system unavailability if the test period of a test procedure changes as well as the function of optimizing the test periods of safety-related test procedures. The RDMS can be utilized in handling the requests of the regulatory institute actively with regard to the reliability validation of safety systems.
There are many different types of open pit mining operations around the world, and the challenge for any drive system manufacturer is to produce a system(s) that will work satisfactorily in these mines. Several factors must be considered such as vehicle speed requirements, available engine horsepower, mine rolling resistance, grades, grade lengths, payload, and tire sizes. How well a particular drive system performs depends on the size, weight, and available tractive/retarding effort. In addition to performance, the system must also have an operating cost that will be acceptable over the life of the equipment. Today the choice of drive systems is not only between mechanical and electrical drives, but also within these categories are the different manufacturers. Regardless of how the power is provided to the rear wheels, the job must be accomplished reliably and at an acceptable ...
A novel adaptive stabilizer, called an Adaptive Governor Power System Stabilizer (AGPSS), which operated on the governor turbine system, was described. There has been extensive research on adaptive excitation control of generators in power systems with the goal of achieving better dynamic performance. AGPSS tracks the frequency and damping of oscillations in a power system, and adjusts to ensure that there is always sufficient damping in the system. There is no interaction between stabilizers on different generating units, and each one acts independently, consuming oscillation energy locally. These stabilizers are easy to design and this facilitates their use in multimachine systems. Results obtained by nonlinear simulation of a single-machine and a three-machine power system were discussed, illustrating the effectiveness of the stabilizers ...
Several systems have been developed to accomplish vehicle location. The systems consist of three types: Dead Reckoning, Satellite, and LORAN C. If the information is to be sent back to a central location, some type of radiocommunication system is needed. One can use the existing voice radio or add a radio system just for transmitting the data.
A decoupled characteristic between the damping of a specific swing mode and the stabilizer gain of the corresponding machine in multimachine power systems is identified. Using this decoupled characteristic a power system stabilizer (PSS) synthesis approach which is based on the phase compensation concept is verified on a 9-machine system and the dynamic performance of this system is significantly improved. This method is proved to be effective, simple and it can provide useful guidance for the PSS field tuning.
This paper establishes a standardization procedure in which results are presented in ready-to-use charts for the economic evaluation of biogas plants. It is hoped this work will alleviate controversial reports on cost-effectiveness of biogas systems. Also, it is found that these systems are the most economic among renewable energy systems using a standardized procedure for their comparison augmented by the generated spider diagrams wherein most probable costing production values for each system are directly compared. (author).
A semi-automatic system which considers operation in a face by monitoring technological parameters of an extraction vehicle and a longwall conveyor is examined. The system records in tabular form the location, progress made, operating and down time of an extraction vehicle and operating and down time of the conveyor. A description of the operating principle system and systems for arrangement of the remote sensing and central recording device are presented. (Note: extraction vehicle not identified: LTN)
A tiered communications architecture for managing network traffic in a distributed system. Communication between client or control computers and a plurality of hardware devices is administered by agent and monitor devices whose activities are coordinated to reduce the number of open channels or sockets. The communications architecture also improves the transparency and scalability of the distributed system by reducing network mapping dependence. The architecture is desirably implemented in a proton beam therapy system to provide flexible security policies which improve patent safety and facilitate system maintenance and development.
This book contains the proceedings of the International Topical Meeting on Remote Systems and Robotics in Hostile Environments. It is organized under the following sessions: Worldwide Applications Overview; Operating Mobile Systems; Sensors and Control Systems; Space Applications; Reactor Operations and Surveillance; Remote Equipment for Hazardous Operations; Future Mobile System; Mining and Construction Operations; Special Applications; Hot Cell Applications; Processing; Reactor Operations and Maintenance; Decontamination and Waste Handling; Remote Handling Development and Demonstration.
Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.
The basic design of a system installed in the Columbus, Ohio Zoo is described. The distribution system is described in detail. The control system is microprocessor controlled, with about 50 monitoring points. Preliminary evaluations have indicated that the system can operate with an overall coefficient of performance in excess of 3.5. 1 figure.
The purpose of this paper is to describe instrumentation and control (I C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I C systems of the next generation of liquid metal reactor (LMR) plants.
The purpose of this paper is to describe instrumentation and control (I&C) system improvements at Experimental Breeder Reactor 11 (EBR-11). The improvements are focused on three objectives; to keep the reactor and balance of plant (BOP) I&C systems at a high level of reliability, to provide diagnostic systems that can provide accurate information needed for analysis of fuel performance, and to provide systems that will be prototypic of I&C systems of the next generation of liquid metal reactor (LMR) plants.
Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems
The purpose of this paper is to describe the embedded computer systems approach taken at Experimental Breeder Reactor II (EBR-II) for non-safety related systems. The hardware and software structures for typical embedded systems are presented The embedded systems development process is described. Three examples are given which illustrate typical embedded computer applications in EBR-II.
In this paper, we extend the diversity and multiplexing tradeoff (DMT) analysis from point-to-point channels to cellular systems to evaluate the impact of inter-cell interference on the system reliability and efficiency. Fundamental tradeoff among diversity order, multiplexing gain and inter-cell interference intensity is characterized to reveal the capability of multiple antennas in cellular systems. And the detrimental effects of the inter-cell interference on the system performance of diversity and multiplexing is presented and analyzed.
Using the Philips DRM distributed real-time multiprocessing system, designers can implement high-performance computer systems using VME hardware and the C programming language. The system provides a virtual-processing environment in which several 68000 CPUs share the workload. There are no centralized components, and tasks can be assumed by the rest of a system in the event of an individual processor's failure.
The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor air quality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)
Within this paper the potentialities of using networked embedded systems will be discussed. New embedded hardware with network connectivity allows remote administration and software updates of solar thermal system controllers via internet. System self analysis helps to minimize breakdown times by sending email and SMS to request maintenance staff. (orig.)
This paper describes New York State Electric and Gas Corporation`s concept for a comprehensive, centrally located data system for management of their continuous emission monitoring systems (CEMS) data. The topics of the paper include the power system`s mix of generating units; data reporting requirements; data base management; nitrogen oxides compliance tracking; sulfur dioxide, nitrogen oxides, carbon dioxide and flow monitoring; and allowance tracking.
The conceptual system requirements for the control, data, robotics, and project management (CDRM) system for the next generation of fusion experiments are developed by drawing on the success of the Tara control and data system. The requirements are described in terms of an integrated but separable matrix of well-defined interfaces among the various systems and subsystems. The study stresses modularity, performance, cost effectiveness, and exportability.
This report deals with the selection of a data communication system for a remote metering system. It covers the following three types of systems: fiber optic, telephone line, and radio packet. It provides a methodology for selecting a communication system for a given remote metering system and a method for comparing costs.
A knowledge based system for pitting corrosion is presented. It can be used for material selection for specific pitting corrosion conditions or to check the suitability of a chosen material. The user can enter his own knowledge. The expert system is an integration of traditional expert system technology and neural networks. (orig.)
In this paper the robust stability analysis of a single machine infinite bus system is investigated using interval matrix theory. Specifically the parameters of the power system stabilizer are considered as uncertainties in the system A matrix. The range of these parameters for which the system is Hurwitz stable is then found using interval matrix theory. (Author)
Dynamic stability improvement of a longitudinal power system using a power system stabilizer (PSS) and a static VAR compensator (SVC) is reported in this paper. An analytical approach is developed for the determination of PSS parameters. Results from time domain simulations indicate that the PSS and the SVC are very effective in damping system oscillations.
Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.
This report presents the methodology and the results from the modelling of an open repository for spent nuclear fuel in Laxemar. Specifically, the present work analyses the hydrological effects of the planned repository during the construction and operational phases when it is open, i.e. air-filled, and hence may cause a disturbance of the hydrological conditions in the surroundings. The numerical modelling is based on the SDM-Site Laxemar MIKE SHE model. The modelling was divided into three steps. The first step was to update the SDM-Site Laxemar model with a new hydrogeological bedrock model. The other main updates were an increase of the depth of the MIKE SHE model domain, enhanced vertical computational resolution and that the drainage of the Aespoe Hard Rock Laboratory was included in the model. The resulting model was used to simulate undisturbed natural conditions. The next step was to describe the open repository conditions, using Laxemar layout D2, by implementing the access ...
One of the requirements for a federated information system is interoperability, the ability of one computer system to access and use the resources of another system. This feature is particularly...Full Text Available
Transposon-based integration systems have been widely used for genetic manipulation of invertebrate and plant model systems. In the past decade, these powerful tools have begun to be used in...Full Text Available
Immunotoxicity encompasses both reduced and heightened immune function. Diverse chemicals can impair functioning of the immune system. Both monographs and books have been devoted to detailed descriptions...Full Text Available
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation solenoids; (2) heat leaks to various ...
This report gives the results of a survey of operational flue gas desulfurization (FGD) systems on coal-fired utility boilers in the United States. The FGD systems installed on Units 1 and 2 at the Bruce Mansfield Station of the Pennsylvania Power Company...
This document establishers the Software Configuration Management Plan (SCMP) for the software associated with the control system of the Sodium Removal System (SRS) located in the Interim Examination and Maintenance (IEM Cell) Facility of the FFTF Flux Test.
This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear ...
Systemic chemotherapy has been relatively ineffective in the treatment of malignant brain tumors even though systemic chemotherapy drugs are small molecules that can readily extravasate across the porous...Full Text Available
When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system.
Plants have too long been ignored as useful screening and monitoring systems of environmental mutagens. However, there are about a dozen reliable, some even unique, plant genetic systems that can increase...Full Text Available
The highly variable and intermittent pollutant concentrations and flowrates associated with wet-weather events in combined sewersheds necessitates the use of storage-treatment systems to control pollution.An optimized combined-sewer-overflow (CSO) control system requires a manage...
A tutorial account is given of the main characteristics and distinctive features of conceptual magnetic fusion systems employing the magnetic mirror principle. These features are related to the potential advantages that mirror-based fusion systems may exhibit for the generation of economic fusion power.
1 to the operator of a waste collective system by an agreement or contract. The conditions for the ...Fees of the waste collective system are subject to the supervision of the authority responsible for market surveillance. ...The operator of waste collection system collects wastes from producers and holder and transports these to a collection
User acceptance of a computer system depends on a number of factors, including broad social and professional concerns regarding the system's impact on the work environment. This observation is especially...Full Text Available
This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.
An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs. (DG)
An overview is presented of the FFTF reactor and plant together with descriptions of core components, core internals, core system, primary and secondary control rod system, reactor instrumentation, reactor vessel and closure head, and supporting test programs.
This paper describes the technical design and performance of the diagnostic system installed in the tokamak TCABR to measure parameters of the plasma edge. The system consists of four Langmuir probes under remote control. (author)
The 'high-tension distribution line design support system' was developed for the 'work design support system'. This support system is composed of the work outline editor for preparing work details and facility data and the inference engine for preparing practical design plans, and can check system conditions such as voltage drop and deviation from technical standards automatically. The work outline editor takes charge of selection of work items, selective input of system information, and setting of some conditions such as pole position and reserved load onto a system diagram. The inference engine provides the design plan automatically based on the information inputted by the editor. For the design of high-tension distribution line, such various factors as local condition and load sharing of distribution ...
This report presents a study on the use of computerised, continuous remote monitoring systems for fire and explosive atmosphere safety in underground coal mines. The effects of these systems on the safety level in mines are investigated, and the relationship between mine safety regulations and computerised, continuous, remote monitoring is analysed.
The objective of this project is to reduce energy consumption in 203 buildings by providing a new EMCS (Energy Monitoring Control System) to control and monitor systems.
The author compares the UHF Follow-on and MILSTAR satellite communication systems. The comparison uses an analytical hierarchy process. Although the two systems have been tasked with different missions, a comparison of cost, capability, and orbit is condu...
Our understanding of the development of neurotransmitter systems in the central nervous system has increased greatly over the past three decades and it has become apparent that drug effects...Full Text Available
A closed loop control process assures that a system performs within control limits. In closed loop control, the system's output feeds back directly to change the system's inputs. We describe an approach...Full Text Available
A simple beam-forming system is described for the electrostatic accelerator of the Scientific-Research Institute of Nuclear Physics of Moscow State University. The system allows the beam to be focused on targets at various distances for a conductor potential of from 1 to 4 MV and beam currents of up to 35 #mu# A.
Algebraic properties of the analytical model, describing electro-magnetic weak interaction with the two-level system with two-fold degenerate state are considered. The expressions for the coherent states and Green function of the system are obtained.
Incorporation of clinical decision support (CDS) capabilities is required to realize the greatest benefits from computerized provider order entry (CPOE) systems. Discussions at a conference on CDS in...Full Text Available
This paper presents the design and implementation of a clinical picture archiving and communication system (PACS) module within the radiology department of a 700-bed teaching hospital. The system is...Full Text Available
... in this paper is aimed at developing a computer vision system that will be used to automatically grade rough hardwood lumber. The purpose of the computer vision system is to locate and identify grading def...
...Acquisition Regulations System 3 2010-10-01...Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF...assumption of risk for transportation by conveyance on...Missiles, and Space Launch Vehicles,...
The present paper considers the evaluation of timber structures with the focus on robustness due to connection ductility. The robustness analysis is based on the structural reliability framework applied to a simplified mechanical system. The structural timber system is depicted as a parallel system. An evaluation method of the ductile behaviour is introduced. For different ductile behaviours, the system reliability is estimated based on Monte Carlo simulation. A correlation between the strength of the structural elements is introduced. The results indicate that the reliability of a structural timber system can be significantly increased due to the ductile behavior.
A first sub-set of the collimation system has been installed for the 2008 first beam commissioning of the LHC. It included 88 collimators around the ring and the two injection lines. Each collimator has two jaws for which must be controlled and monitored with high precision. The LHC collimation system was put into operation from July to October 2008. The installed system is described and first results from system operation without and with beam are presented. It is shown that the LHC collimation system achieved the specified accuracy and reproducibility of jaw positioning. Next steps in collimation commissioning are described and planned system upgrades for high beam intensities are outlined.
Several neutron radiography systems designed to view transient processes on a real-time basis have been developed. With the advent of these different real-time systems comes the necessity to develop a means to quantitatively evaluate and compare these systems. A suitable method for measuring the resolution capabilities of the image-forming system is the determination of the modulation transfer function (MTF). The MTF is a measure of an imaging system's ability to reproduce the spatial frequencies present in an image. The system in use at the University of Missouri Research Reactor is described. (Auth.).
The vacuum system of the XVTS (X-Ray Vacuum Transport System) for the LCLS (Linac Coherent Light Source) XTOD (X-ray Transport, Optics and Diagnostics) system has been analyzed and configured by the Lawrence Livermore National Laboratory's NTED (New Technologies Engineering Division) as requested by the SLAC/LCLS program. The system layout, detailed analyses and selection of the vacuum components for the XTOD tunnel section are presented in this preliminary design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated. Also included are the plans for procurement, mechanical integration, and the cost estimates.
Fastening systems for parts that endure high vibration shear loads have traditionally been difficult or expensive to produce. This application describes a fastening system with multiple conical surfaces and eccentric offsets. The novel conical fastener system allows parts to be assembled with reduced tolerance controls at interface features while improving alignment precision. The eccentric conical fastening system is particularly well suited for assemblies with high shear loads in high vibration/shock environments, and/or for systems that have extremely precise pointing requirements.
Renewable energy systems (RES) are unique among energy supply systems because their performance and design depends entirely on the location and climatic conditions. As a result of design options, user requirements and local climatic conditions, there are enormous variations between RES. This paper describes a method how to evaluate the data on monitored renewable energy systems (RES) in such a way that the operating conditions and performance of individual components and the system as a whole can be analysed and compared. It shows how categories of similar use can be defined and recommendations for each category can be made to assist in the selection of the most suitable products. (orig.)
A self-tuning PID (proportional-integral-derivative) power system stabilizer (PSS) is presented for improving the dynamic stability of a multimachine power system over a wide range of operating conditions. In order to maintain good damping characteristic when there is a drastic change in system operating condition, the gain settings are adapted in real time based on the continuously measured system inputs and outputs. The proposed self-tuning stabilizer has a decentralized structure and only local measurements within each generating units are required for the adaptation process. The effectiveness of the proposed stabilizer is demonstrated by an example.
This paper proposes the design of LQ-PSS (linear quadratic power system stabilizer) for improving power system stability using genetic algorithm(GA). We are turned weighting matrices of LQ-PSS using GA. To evaluate the usefulness of the proposed method, we performed the nonlinear simulation on a single machine infinite system. As results on a single machine infinite system. As results of the simulation, the proposed method shows the better control performance than CPSS(conventional power system stabilizer) in terms of settling time and damping effects. (author). 7 refs., 7 figs., 3 tabs.
Many power apparatus and underground cable systems have been constructed since 1970 in korea. Recently, as the needs for underground T and D systems increase rapidly, any fault on the systems causes enormous economic losses in our society. Thus, this paper described. (1) Survey on the amount and the increasing rates of the underground cable systems at home and abroad. (2) Survey on fault data for the underground cables and joints at home and abroad.From the analysis on fault data, we analyzed the cause of fault and classified the typical fault mode for the underground cable systems. (author). 5 refs., 3 figs., 11 tabs.
... Accession Number : ADD815206. Title : Waterjet Cutting System Adds Value to Titanium Parts. Descriptive Note : Journal article. Corporate Author : ...
Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
Installation of the major hardware subsystems for MFTF is nearing completion. These subsystems include the Fusion Chamber System, the eighty KV Neutral Beam System, the Superconducting Magnet System, and the Personnel Safety System. The Local Controls group has undertaken a uniform aproach to implementing the control systems for all of these hardware subsystems. This approach has two major aspects: (1) to provide a stand-alone computer control system with a remote, portable terminal so that computer control can be provided at the site of the hardware for initial testing, (2) to provide hardware simulators so that the complicated MFTF computer control system can be tested independent of the hardware. The software and hardware tools which were developed to carry out this plan will be described. Our experiences with bringing up subsystems ...
... Title : The Numerical Weather Prediction System at the Italian Air Force Weather Service: Impact of Non-Conventional Observations and Increased ...
The Johns Hopkins Hospital has initiated an ambitious program to apply modern technologies to the development of a new, comprehensive clinical information system. One component of this system is a...Full Text Available
Oct 2, 2007 ... Other payloads included the Orbiter Experiments Autonomous Supporting Instrumentation System-1 (OASIS-1), a cooling system designed for ...
(AIM PAPER 81-1628). Three different examples will be given to illustrate how a ...... Power System (PS), and a Science Applications and Space Platform ...
Recognizing that a high percentage of transmission-line faults are single-phase to earth and temporary in nature, provides the impetus for considering single-pole switching as a means to enhance the reliability of EHV transmission systems. The effectiveness of single-pole switching schemes is largely determined by the speed with which the secondary arcs extinguish, and hence allow system restoration. Simulation techniques that enable better prediction of the faulted-system response are of obvious importance to the design and assessment of the various single-pole switching scheme applications. In this thesis, digital methods are developed to enable the faulted response of EHV systems to be simulated for a variety of different single-pole switching schemes. These include conventional single-pole switching, the hybrid method of autoreclosure, the neutral switched reactor, and the High Speed Grounding ...
The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various transaction activities in the system is controlled through the level of MASS user privilege. Details of MASS user ...
Mar 2, 2011 ... United Technology spun off a new company, Waterjet Systems, to commercialize and market the technology. The resulting ARMS (Automated ...
lytical Comparison of Turbine-Blade Cooling System Designed for a. TurboJet Engine Operat- at Supersonic Speed and Altitude. I1 -. Air-C~Oling Systems. ...
The antiphospholipid syndrome (APS) is a multi-systemic disease being characterized by the presence of antiphospholipid antibodies that involves both arterial and venous systems resulting in arterial...Full Text Available
Jun 16, 2011 ... The research is part of a team effort to help the hardwood sawmill industry automate with computer vision systems, and computer-aided or ...
This manuscript discusses the physiology of the autonomic nervous system (ANS). The following topics are presented: regulation of activity; efferent pathways; sympathetic and parasympathetic divisions;...Full Text Available
Apr 7, 2011 ... You cannot be in any type of pay status (e.g., annual leave, sick leave, .... Retirement System (FERS) and the Civil Service Retirement System ...
... Waste Collection Systems Products and Equipment Find and compare a variety of waste collection systems products and equipment on the world's largest environmental industry portal. View product ...
...Systems, UWA investigating rate uplift effects of shallow foundation systems associated with high voltage transmission line support towers. This work was funded by National Grid, ...
... System (CSRS) and the Federal Employees Retirement System (FERS). ... retirement, thrift savings plan, annual and sick leave, severance pay and ...
Invasive fungal infections can be devastating, particularly in immunocompromised patients, and difficult to treat with systemic drugs. Furthermore, systemic administration of those medications...Full Text Available
... operational AUV and Unmanned Underwater Vehicle (UUV) ... by Brooks with land-based robots [BROOKS 88 ... system for a mobile land robot called ...
Advances in geographic information system (GIS) technology, developed by geographers, provide new opportunities for environmental epidemiologists to study associations between environmental exposures...Full Text Available
The recent accumulation of genomic information of many representative animals has made it possible to trace the evolution of the complement system based on the presence or absence of each complement...Full Text Available
An inspection system was developed for spent fuel assemblies of PWR so that to check their general state, perform dimensional control and measure oxide layer thickness of peripheral rods. (orig./HP)
The DN-tracking method is used to prove the existence of a closed trajectory in a quadratic system of ordinary differential equations in three dimensions.
... Abstract : The United States Air Force (USAF) currently operates the Milstar satellite system to provide Military Satellite Communication Systems ...
Of the many energy-conservation options available to the design engineer, a system-management approach is recommended as one that will effect maximum benefits to the owner. Systems management includes energy-conscious consideration of design criteria, design details, installation, testing and balancing, and operation. It requires the informed participation of the design engineer, contractor, testing and balancing (TAB) engineer, and owner/operator. Within limits, almost every component of HVAC systems offers an opportunity to conserve energy. Many of these impact energy determinants such as system static pressure, system total air flow, or the quantity of outside air. A few design considerations for energy conservation in a simple system and the impact that the TAB work has on these are illustrated. Particular attention is devoted to the energy impact of ...
The symposium reviewed the use of electronics in mining today. Subjects covered include control systems; remote sensing; telemetry; data transmission; microprocessors and transportation systems. 15 papers have been abstracted separately.
This standard establishes requirements, verification criteria, and contractor tasks for electromagnetic effects protection of airborne, ground, and support systems. These effects include electromagnetic compatibility, electromagnetic interference, lightni...
... Abstract : The electric resistance in weak (diluted) solid solutions of the Pd-Ag and Fe-W systems, as wellAS THE Hall effect in a Pd-Ag system ...
This standard specifies requirements for the flameproofing and the limiting of surface temperature and exhaust emission control of diesel engine systems for use in underground coal mines.
Contact scanner system in Wolsung NPP(model ESE-1565) is early `70 equipment so most of components are obsolete. To make 100% compatible PCBs for this system is main object of the study. Most of components used in the system are now not available in the electric market, furthermore original system maker no longer supplies spare parts. System supplier(AECL) quoted lots of money than general PCBs prices in case of spare PCBs are re-marked by canada maker. Contents and scope of the study are specifications research and system analysis, improvements of repairability and reliability, circuit design and simulations using computer aided tools(CAE), make arbitrary mechanical contacts signal generator for test system. Now the long-run test of home made PCBs are conducting at Wolsung NPP. (author). 20 refs., 42 figs.
Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...
Systemic lupus erythematosus (SLE) persists as a chronic inflammatory autoimmune disease and is characterized by the production of autoantibodies and immune complexes that affects multiple organs....Full Text Available
... 4? Program History 5? Center for Advanced Materials and Smart Structures 6? Center for Systems ... Systems 14? Center for Photonic Materials Research 15? Synthesis, Manufacturing and Characterization ...
The Systems Development Group and the Pharmacy Service of the Washington D.C. VAMC are involved in automating the administrative and clinical data requirements of a satellite out-patient pharmacy....Full Text Available
In the analysis of power systems security, recently a new concern related to possible malicious attacks caught much attention. Coordination among different transmission system operators (TSO) in an interconnected power system to counteract such attacks has become an important problem. This paper presents a general framework for describing the physical, cyber and decision-making aspects of the problem and their interrelations; within this framework, an analytic tool for the assessment of information impacts in handling on-line security after a malicious attack is proposed and discussed. The model is based on the socially rational multi-agent systems and the equilibrium of a fictitious play is considered to analyze the impacts of various levels of information available to the interconnected system operators on the outcomes of the decision-making process under attack. A 34-buses test ...
The immune system plays a crucial role in maintaining health; however, accumulating evidence indicates that this system can be the target for immunotoxic effects caused by a variety of chemicals including...Full Text Available
... reliability of fiber optics in preference over space-based systems. ... STC web site at www.aiaa.org/tc ... and improve lethalities of US weapon systems 3 ...
By the turn of the century, American farmers and ranchers will be producing food and fiber through the application of highly sophisticated systems that involve a broad spectrum of relevant factors--from...Full Text Available
A method and apparatus for determining the condition of tissue or otherwise making chemical identifications includes exposing the sample to a light source, and using a synchronous luminescence system to produce a spectrum that can be analyzed for tissue condition.
Primates are remarkably good at recognizing objects. The level of performance of their visual system and its robustness to image degradations still surpasses the best computer vision systems despite...Full Text Available
In this paper, we have designed power system stabilizer (PSS) using object-oriented method. There are several types of power system stabilizer, A proportional-integral (PI) controller is very simple for practical implementation. Therefore it has been widely employed by the industry. The methods of obtaining the gains (Ki,Kp) of PI controller are root-locus method and sub-optimal regulator approach. But these methods are cannot be applicable to nonlinear system and faulted power system. So we proposed a new method which can be applied to nonlinear system by numerical analysis method. The method of dynamic system simulation by numerical method is very difficult and complex. We proposed flexible simulation method for complex power system analysis using object-oriented programming (OOP) and applied to PI controller design. (author). 7 refs., 14 ...
... 1 I3a TYPE OF REPORT 1 3b TIME COVERED ... Measured by this standard the system provides good results; it ... did not fully meet all the standards or ...
A set of computer programs is described which constitutes a clone database management system. Maintenance of the database and the stocks of material is designed to be under the control of one person...Full Text Available
Three agricultural applications in a specially designed greenhouse solar system functioning as a multi-purpose solar air collector for crop production and curing/drying processes are examined. An automated hydroponic crop production system is proposed for the greenhouse solar system. Design criteria of the proposed system and its utilization of solar energy for root-zone warming are presented and discussed. Based upon limited testing of the hydroponic system considered, hydroponic production of greenhouse crops is believed reasonable to complement the year-round use of the greenhouse solar system. The hardware/software design features of a microcomputer-based control system applied in the greenhouse solar barn are presented and discussed. On-line management and utilization of incident solar energy by the microcomputer ...
Concerning the above, it is discussed whether such a system is feasible in Japan. A zinc/air cell system requires some special plants for zinc regeneration, etc. It is necessary to build a zinc refining plant and to install dozens of electrode replacing facilities in an area dozens of kilometers in diameter with the plant at the center. For such a system to be functional, there have to be several tens of thousands of automobile users in a limited area. In Japan, so large a number will not be found anywhere even if the appeal is directed to those in the postal service and electric utilities. There will be no economic success in Japan, different from in Germany. As for the economic comparison between a zinc/air cell system and natural gas system, the two will be equivalent to each other as far as the use of the quick filling stations for the natural gas automobiles remains as it is. ...
Power system operating conditions vary with system configurations and loading conditions. Coefficients in nominal system model change in a complex manner with different operating point and so does system dynamic behavior. With the aid of unstructured and structured uncertainty descriptions, the worst system variations can be estimated and formulated into two different uncertainty models in frequency domain; multiplicative unstructured uncertainty in the form of transfer function and structured uncertainty with the parametric uncertainty description. The uncertainty descriptions are then incorporated into system nominal model to perform H{sub {infinity}} and {mu} based robust power system stabilizer (PSS) design. Both approaches to the PSS design enable the power system to remain stable over a wide range of ...
A self-optimizing pole-shifting control algorithm has been developed for an adaptive power system stabilizer (APSS) to improve its dynamic performance and autonomous operation. The proposed algorithm deals with the system frequency and time domain characteristics simultaneously to guarantee stability and to enhance the performance of the closed-loop system. The mechanism of discrete control system control limits influencing the closed loop system behaviour is studied. Short-term behaviour is studied by introducing the concept of a short-term behaviour index. With the introduction of dynamic control limits, an effective discrete control system design method is proposed. A PSS oriented power system dynamics simulation package (PSDSP) has been developed. Using the PSDSP, simulation studies were performed with the proposed APSS applied to a ...
may be possible to meet those loads with renewable energy systems &mdashachieving zero-net- energy performance.Solar-thermal heating systems, ...p/p Spencer and others argue that renewable energy systems should be considered only after the building envelope ...energy loads are brought low enough, however, a renewable energy system may make sense financially. p
We introduce the notion of watching systems in graphs, which is a generalization of that of identifying codes. We give some basic properties of watching systems, an upper bound on the minimum size of a watching system, and results on the graphs which achieve this bound; we also study the cases of the paths and cycles, and give complexity results.
Sandia National Laboratories, New Mexico, conducts the Utility Battery Storage Systems Program, which is sponsored by the US Department of Energy`s Office of Energy Management. The goal of this program is to assist industry in developing cost-effective battery systems as a utility resource option by 2000. Sandia is responsible for the engineering analyses, contracted development, and testing of rechargeable batteries and systems for utility energy storage applications. This report details the technical achievements realized during fiscal year 1994.
This paper describes a dissipativity-based framework for the study of low-frequency oscillations in power systems and for power system stabilizer design. This framework leads to a robust controller design formulation, amenable to both H{sub {infinity}} and QFT tools. An illustrating numerical example presents QFT based design for a widely used benchmark two area, four machine power system.
The Gibbs energy of mixing in liquid phase and the Gibbs energy of formation of various compounds in a binary Pu-Cd system were re-optimized by applying both recent and earlier experimental data. Those of the binary Pu-Bi and U-Bi systems were newly optimized. The results were summarized in a database and applied to the preliminary prediction of multi-solute systems in liquid Cd or Bi solvent. (author)
Since nuclear terrorism has been identified as a real threat, the Korean government has earnestly developed elementary technologies and sub-systems for establishing an integrated defensive system against nuclear terrorism, which is based on the concept of defense-in-depth. This paper introduces the gist and implications of the studies that have been conducted in building the national nuclear material tracking system for preventing and intercepting the illicit trafficking and transporting of nuclear material in Korea. (orig.)
The heavy water reactor such as Wolsung No.1 and No.2 has a purification system to purify the reactor coolant. The control system regulates the coolant temperature to protect the ion exchanger. After the fuel exchanges of operating plant, the increase of the coolant pressure makes the purification temperature control difficult. In this paper, the controllability of the control dynamics of the purification system was analysed and the optimal parameters were proposed. To reduce the effects of the flow disturbance, the feedforward control structure was proposed and analysed.
Described herein is a system for the co-generation of hydrogen gas and electricity, wherein the proportion of hydrogen to electricity can be adjusted from 0% to 100%. The system integrates fuel cell technology for power generation with fuel-assisted steam-electrolysis. A hydrocarbon fuel, a reformed hydrocarbon fuel, or a partially reformed hydrocarbon fuel can be fed into the system.
In this paper para boson-fermion supersymmetry is exemplified in simple oscillator systems. The parasupercharge satisfies the ordinary supersymmetry algebra. The parabosonic and parafermionic oscillators do not commute and the energy spectra are non-trivial for even the one level system. The authors calculate the partition functions and compare with those for the non-supersymmetric systems.
In a redox battery using a titanium redox system or chromium redox system as an active material for the negative electrode or a manganese redox system as an active material for the positive electrode, the electromotive force of the battery and the stability of electrolyte solutions are enhanced by addition of a chelating agent such as citric acid or a complexing agent such as phosphoric acid to the redox system used therein.
A reliable inventory control system was developed at the Fast Flux Test Facility (FFTF) to keep track of the occupancy of 900 refueling facility locations, to compile historical data on the movement of each reactor assembly, and to simulate assembly moves. The simulate capability is valuable because it allows verification of documents before they are issued for use in the plant, and eliminates the possibility of planning illegal or impossible moves. The system is installed on a UNIVAC 1100 computer and is maintained using a data base management system by Sperry Univac called MAPPER.
This paper traces the development and progress of magnetic suspension systems and magnetic bearings in the USSR. The paper describes magnetic bearings for turbomachines, magnetic suspension systems for vibration isolation, some special measuring devices, wind tunnels, and other applications. The design, principles of operation, and dynamic characteristics of the system are presented.
Motivation is given for a technique to more thoroughly test semiconductor equipment control systems. A description is given of a simulator-based control system testing technique. Potential benefits that could be realized by using this technique in the semiconductor industry as well as benefits documented by using this technique in other industries are described. Specific requirements for using the technique in the semiconductor industry are outlined. A summary of a survey of nine commercial simulation systems is given. Finally, the outcome of the survey is compared with the requirements for using the technique.
One approach to improving the competitiveness of photovoltaic systems is the development of designs specifically for export applications. In other words, where is it appropriate in a system design to incorporate components manufactured and/or assembled in the receiving country in order to improve the photovoltaic exports from the US? What appears to be needed is a systematic method of evaluating the potential for export from the US of PV systems for various application in different countries. Development of such a method was the goal of this project.
The systems analyses and optimization studies performed in connection with a program to design and evaluate a commercial 663 MWe coal-fired combined cycle power plant using pressurized fluidized bed combustion and advanced technology in the hot gas cleanup system and gas turbines are presented. Details on the plant control system are included. (LCL)
A general theorem on the GBDT version of the B\\"acklund-Darboux transformation for systems rationally depending on the spectral parameter is treated and its applications to nonlinear equations are given. Explicit solutions of direct and inverse problems for Dirac-type systems, including systems with singularities, and for the system auxiliary to the $N$-wave equation are reviewed. New results on explicit construction of the wave functions for radial Dirac equation are obtained.
The purpose of this thesis is to explore possible difficulties and their solutions in transitioning the OTCIXS/TADIXS subsystems from the present Navy UHF Fleetwide Satellite System to the EHF/SHF MILSTAR System. The research provides a description of the...
HEW is operating one of the biggest district heating networks of the Federal Republic of Germany. The paper discusses a number of projects which in recent years have been engaged in extensive air pollution abatement measures to make district heating an environmentally compatible energy source. Emphasis is placed on the hot gas cleanup system of block 2 of the harbor power plant. The system is the first of its kind to have realized an SCR system connected with the desulfurization system for industrial denitrification purposes.
The demands made on data transmission systems by modern mining companies are used to show why the currently used multiplexers cannot satisfy future requirement. The telecommunications department of Bergbau-Forschung GmbH is now developing a telecommunication system for underground work. The requirements made on this system are reported.
An increase in the stability and reliability of a combined power system (OES) is achieved through using a control panel (PA) and regulation systems. A substantial part of the works published in this collection of works is used in the combined power systems of the Urals, the Northwest and Central Asia.
This paper summarizes a method to evaluate the possible effects of magnetohydrodynamic-electromagnetic pulse (MHD-EMP) on power systems. This method is based on the approach adapted to study the impact of geomagnetic storms on power systems. The paper highlights the similarities and differences between the two phenomena. Also presented are areas of concern which are anticipated from MHD-EMP on the overall system operation. 12 refs., 1 fig.
Asean Brown Boveri (ABB) developed Glass (Global access for service and support), a monitoring system for the remote control and management of ABB supplied equipment and other equipment through the Internet. Glass can be applied for many different systems, e.g. automated substations of electric power distribution systems or train equipment
U.S. Department of Energy (DOE) Policy 450.4, Safety Management System Policy commits to institutionalizing an Integrated Safety Management System (ISMS) throughout the DOE complex as a means of accomplishing its missions safely. DOE Acquisition Regulation 970.5204-2 requires that contractors manage and perform work in accordance with a documented safety management system.
Implementation of an adaptive power system stabilizer (PSS) based on linear optimal control is described in this paper. The generator is identified in real time, and a special 3rd order discrete Riccati equation is solved in each sample interval. Because the output of the generator is fed back directly, the controller can track the system very fast. Experimental studies on a physical model of a power system demonstrate the effectiveness of the proposed adaptive optimal controller.
The data on the multilayer operation of the objects, located in the climatic conditions of the central area of Russia and equipped with the geothermal heat-pumping systems of the heat supply are presented. The results of the analytical studies on evaluating the geothermal heat-pumping systems of the heat supply integration efficiency into the structure of the energy supply system, prevailing in the country, are presented
The Flux Mapping System (FMS) of 540 MWe PHWR is a system, which is first of its kind used in Indian PHWRs. It is used to compute a detailed flux/power distribution of the reactor core using modal synthesis method .The paper brings out the high availability features of FMS and the software design philosophy. The paper emphasizes on framework based reusable architectural design, which simplifies and speeds up the development of data acquisition systems. (author)
The results show that the SQUID device eddy current testing system is a suitable tool for NDE. Due to the high low-frequency sensitivity of the SQUID sensor, the SQUID device eddy current testing system permits lower examination frequencies than the conventional eddy current probe system. The SQUID system enhances fault detection in even deeper materials layers. (orig./MM).
Families of regimes for discrete control systems are studied possessing a special quasi-controllability property that is similar to the Kalman controllability property. A new approach is proposed to estimate the amplitudes of transient regimes in quasi-controllable systems. Its essence is in obtaining of constructive a priori bounds for degree of overshooting in terms of the quasi-controllability measure. The results are applicable for analysis of transients, classical absolute stability problem and, especially, for stability problem for desynchronized (asynchronous, switching) systems.
Sandia National Laboratories, New Mexico, conducts the Energy Storage Systems Program, which is sponsored by the US Department of Energy`s Office of Utility Technologies. The goal of this program is to assist industry in developing cost-effective energy storage systems as a resource option by 2000. Sandia is responsible for the engineering analyses, contracted development, and testing of energy storage systems for stationary applications. This report details the technical achievements realized during fiscal year 1996.
This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.
By way of introduction, the author describes the electrical equipment of the power station on the River Traun and then lists the main features of the electrical systems such as generators, transformers, the power transmission systems as, e.g., the generator leads, the 8 kV switch plant, the 110 kV oil-filled cable as well as the station-service, control, protection and monitoring systems. The control of the headwater level and of the mechanical systems of the barrage is described in detail.
The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.
A novel approach to the reliability analysis of a power system with both hydro and pumped storage plants is presented in this paper. The proposed method is based on the concept of peak shaving for the hydro and pumped storage units. Different values of the stored energy of the pumped storage units are employed to demonstrate their effect on the generation reliability of a power system. The proposed scheme has been applied successfully to the reliability analysis of Taiwan power system.
This paper deals with dynamic study of co-generator system with derived dynamic models of generator, excitation system, and turbine/governor from field tests. Mainly this study concentrates on frequency control by under-frequency relay. We simulates dynamic study of co-generator system using EMTDC. (author). 4 refs., 13 figs., 4 tabs.
In this paper a prototype of Requirement Tracking and Verification System(RTVS) for a Distributed Control System was implemented and tested. The RTVS is a software design and verification tool. The main functions required by the RTVS are managing, tracking and verification of the software requirements listed in the documentation of the DCS. The analysis of DCS software design procedures and interfaces with documents were performed to define the user of the RTVS, and the design requirements for RTVS were developed. 4 refs., 3 figs. (Author)
Developing DB system of piping reliability including the population data and service history of damaged piping for pilot power plant. Total weld counts of shop welds, field welds and welds for measuring instruments for 14 systems of Kori unit 3. Total weld counts of shop welds, field welds and welds for measuring instruments for 12 systems of Wolsung unit 2.
This paper discusses the concept of controllable subspace for open quantum dynamical systems. It is constructively demonstrated that combining structural features of decoherence-free subspaces with the ability to perform open-loop coherent control on open quantum systems will allow decoherence-free subspaces to be controllable. This is in contrast to the observation that open quantum dynamical systems are not open-loop controllable. To a certain extent, this paper gives an alternative control theoretical interpretation on why decoherence-free subspaces can be useful for quantum computation.
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the ...
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR ...
The Chernobyl reactor accident has pronupted all European countries to rehabilitate their existing measurement and monitoring systems and to design and erect new ones. These systems are meant to ensure a rapid overview on the situation in case of an accident to adopt suitable actions for protection or prevention. 6 papers report on the state of such measurement systems in Europe, inparticular those in France (TELERAY), in Germany (IMIS) and in Switzerland (RADAIR). The IMIS-system is discussed for its extension to Eastern Germany. (HP).
An approach to solving the problem of managerial control quality improvement corporate information-calculating networks (CICN) is proposed. The approach is based on the concept of a flexible toolkit. A macro-model, system-science and system-engineering models of an intelligent managerial control system (IMCS) for CICN development are considered as well as its dynamics. The practical opportunity of IMCS implementation is assessed. (5 refs).
An experimental plan for improving the problems of failed fuel location system in Wolsung Unit-2 reactors was established. It is not possible to make an experiment on the failed fuel monitoring nuclides in the cold laboratories because they have very short half life. Therefore, the experiments can be only carried out at the existing monitoring system under reactor operation. For that reason, an experimental plan was drawn up for installing the radiation detection system on reactor site.
A description is given of an automatic liquid nitrogen pumping system. Pamping of liquid nitrogen iato cooling traps up to a predetermined level is achieved by an automatically controlled compressed air system. An impontant feature of the equipment is the ability to switch automatically from an empty liquid nitrogen reservoir to a full one. This allows for a much more flexible operation than in conventional systems where the reservoir has to be replaced manually when empty. (auth)
A dual-rate self-tuning control technique, in which the system identification and control calculation are performed separately, is proposed in this paper. This greatly increases the control rate. A self-tuning power system stabilizer (DSPSS) making use of this technique is developed and implemented using multi-micro-computers. Simulation and experimental results with DSPSS show that the increase in the control rate can considerably improve the system performance.
Characteristics of embedded systems are discussed. In particular, the role of the computer in such systems is highlighted. Special emphasis is placed on the different requirements different kinds of systems may place on program execution. From such requirements necessary programming constructs are derived and in an overview of currently used languages it is shown how evolution led to modern languages like Ada and CHILL. With the advent of cheap, fast and small processing units, exploitation of parallelism for enhancing system performance is becoming increasingly tempting. However, few languages support the design of such multi-processor systems. Some methods for dealing with this problem are discussed. Finally, systems architectures and associated languages for the use of techniques originally developed for AI research are adumbrated. (Auth.).
By means of an analogous simulator, which can simulate a power supply system, a method to determine the transfer function of a Power System Stabilizer (PSS) is developed. The purpose of the PSS is to damp unwanted electro-mechanical oscillations. The method is very systematic and there is no need for specified values of the parameters used in the system. It is assumed that the power generator system is linear for small variations. The system can be considered to be a black box. Measurements executed by means of this method are completely controlled by the person who enforces the measurement. By applying this method carefully, irregularities are almost out of the question. The equipment necessary are a PC with two AD-ports and an adjustable sinus-generator. A comparison is made with a more traditional method, in which a spectrum analyzer is used. 4 figs., 7 refs.
A three-level approach to viability is developed, considering (1) living systems, (2) a niche, understood as the area within the reach of their actions, and (3) an environment. A systematic analysis of the interrelations between these levels shows that living systems emerge with matter/energy processing systems. These can add controller structures when producing excess energy. A three-sensor controller structure enables a living system to deal with unfavourable and scarce environments. Further evolution of these controller structures offers improved ways to act on niches. Maintaining niches in scarce environments can require technology or economy. So social systems emerge, which are understood as aggregates of living systems. Basic patterns of interactions within social systems are analyse...
Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
A decentralized power system stabilizer output feedback design approach is considered, which is compatible with expanding the construction of multi-machine systems. We presume that the interconnected power system is constructed by connecting closed-loop subsystems one after another. We take the proper stable factorization approach for calculating the local compensators. We apply the result to the new subsystem at each connection stage with unfixed power system stabilizer parameters. We then determine the parameters appropriately, before connection, so that the expanded system is stable after connection. A numerical example is worked out to illustrate the proposed design technique. 14 refs, 5 figs, 3 tabs
This paper analyzes the F-policy M/M/1/K queueing system with working vacation and an exponential startup time. The F-policy deals with the issue of controlling arrivals to a queueing system, and the server requires a startup time before allowing customers to enter the system. For the queueing systems with working vacation, the server can still provide service to customers rather than completely stop the service during a vacation period. The matrix-analytic method is applied to develop the steady-state probabilities, and then obtain several system characteristics. We construct the expected cost function and formulate an optimization problem to find the minimum cost. The direct search method and Quasi-Newton method are implemented to determine the optimal system capacity K, the optimal thre...
Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).
Many existing methods of identifying the optimum sites for installing power system stabilizers (PSSs) in multi-machine systems are restricted to the sequential PSS application, which considers the enhancement of damping of just one critical electromechanical mode at a time; the eigenstructure analysis of the open-loop system, which does not take the control matrix (i.e., the B matrix in the linearized model x = Ax + Bu for power systems) into consideration. This paper presents a method of identifying the optimum sites for installing power system stabilizers. The advantages of this method are: it can identify the optimum sites for installing PSSs so that several electrochemical modes are damped out simultaneously; it takes both the eigenstructure of the open-loop system and the control matrix into consideration.
The Idaho Explosives Detection System was developed at the Idaho National Laboratory (INL) to respond to threats imposed by delivery trucks potentially carrying explosives into military bases. A full-scale prototype system has been built and is currently undergoing testing. The system consists of two racks, one on each side of a subject vehicle. Each rack includes a neutron generator and an array of NaI detectors. The two neutron generators are pulsed and synchronized. A laptop computer controls the entire system. The control software is easily operable by minimally trained staff. The system was developed to detect explosives in a medium size truck within a 5-min measurement time. System performance was successfully demonstrated with explosives at the INL in June 2004 and at Andrews Air Force Base in July 2004.
Development of a front end system for a high energy proton accelerator is in progress at Korea Atomic Energy Research Institute (KAERI) for basic science and industrial applications. The proper vacuum components has been installed and operated successfully between ion source and RFQ. The reliable operation of the accelerator has been completed at vacuum system in the high and ultra high vacuum range under operating conditions. Proper control system for the vacuum instruments, based on PC operated by Windows, has been designed and constructed by control group at PAL. As PC operated by windows with inherent instability does not proper, embedded system can be replaced for reliable operation system, such as VME system operated by vxWorks.
We consider the effect of distributed delays in neural feedback systems. The avian optic tectum is reciprocally connected with the nucleus isthmi. Extracellular stimulation combined with intracellular recordings reveal a range of signal delays from 4 to 9 ms between isthmotectal elements. This observation together with prior mathematical analysis concerning the influence of a delay distribution on system dynamics raises the question whether a broad delay distribution can impact the dynamics of neural feedback loops. For a system of reciprocally connected model neurons, we found that distributed delays enhance system stability in the following sense. With increased distribution of delays, the system converges faster to a fixed point and converges slower toward a limit cycle. Further, the introduction of distributed delays leads to an increased range of the average delay value for ...
IHI has developed a new Three-Dimensional Computer-Aided Design (3D-CAD) system to improve the design efficiency and quality of the steel structure of nuclear power plants. This system covers every design phase from the initial arrangement of structure to the production design sharing the same database. The system incorporates the design rules and professional expertise of designers, and enable easy and efficient design. The system can easily generate the three-dimensional data for structures, model data for stress analyses and composite arrangement data. The system has already been applied to several plants under construction and has achieved excellent results. The outline of the new CAD system is introduced. (author)
A pipeless batch plant is a batch processing production system using mobile vessels. The plant performances depend on both hardware of equipment and software of operation. So the plant includes many design factors such as number of vessels, stations and AGVS, layout of stations, vessel moving rules, job scheduling and so on. In this paper, the characteristics of pipeless batch plant design are considered to handle the problem by the systems engineering approach. Then, a practical design method known as design-by-analysis is applied to solve such a complex design problem. Based on this concept, a design support system composed of modeling, simulation and evaluation subsystems is developed. This system enables rational decision making through performance evaluation for proposed design of a pipeless batch plant. The usefulness of the system is illustrated by industrial examples. 12 ...
This paper presents a practical design for a power system stabilizer using the differential geometric linearization approach. This stabilizer uses the information at the secondary bus of the step-up transformer as input signals, enabling its application to multi-machine power systems. The stabilizer makes it possible to obtain all necessary information within its own power station without observing an equivalent reactance in other power systems. To evaluate the dynamic performance of this stabilizer, the authors tested it on a multi-machine system model using the computer. The simulation results showed that the stabilizer offered good dynamic performance and robustness compared with conventional power system stabilizers, thus confirming its very effective and practical application in power system stabilization.
In this paper the concept of a composite power system stabilizer is investigated. This stabilizer comprises a properly designed, robust, conventional power system stabilizer (CPSS) and an auxiliary stabilizer (AS) which can be either a self-tuning stabilizer (ASTS) or a fixed-parameter stabilizer (AFPS). For small disturbances, the CPSS performs satisfactorily over a wide range of operating conditions. When large disturbances occur the auxiliary stabilizer augments the performance of the CPSS. It has been demonstrated that the composite power system stabilizer can significantly improve the dynamic performance of the system when there is a major disturbance such as a short circuit in the system. Because in the case of a single-machine system the parameters of the ASTS do not vary appreciably, it can also be implemented as a fixed-parameter device; this simplifies ...
An adaptive power system stabilizer (APSS) employing a new self-optimizing pole shifting control strategy and its application to a power system are described in this paper. Based on an identified model of the system, the control is computed by an algorithm which shifts the closed-loop poles of the system to some optimal locations inside the unit circle in the z-domain to minimize a given performance criterion. With the self-optimization property, outside intervention in the controller design procedure is minimized, thus simplifying the tuning procedure during commissioning. Also, a new method of calculating the variable forgetting factor in real-time parameter identification is discussed. Studies show that the proposed APSS can provide good damping of the power system over a wide operating range and significantly improve the dynamic performance of the system.
In this work, we propose a conceptual distributed control framework for electrical grid integrated with distributed renewable energy generation systems in order to enable the development of the so-called ''smart electrical grid''. First, we introduce the key elements and their interactions in the proposed control architecture and discuss the design of the distributed control systems which are able to coordinate their actions to account for optimization considerations on the system operation. Subsequently, we focus on a specific wind/solar energy generation system connected to a reverse osmosis water desalination system and the electrical grid and design two supervisory predictive controllers via model predictive control to operate the integrated system taking into account short-term and lo...
This paper describes a comprehensive MCM [machine condition monitoring] program and suggested system for implementation in hydroelectric generating units. The system addresses all the major subsystems which make up the generating unit. A modular design means that it could be applicable in a wide variety of situations. Different subsystems may be included or excluded from the monitoring system as required. It may be used at individual plants as a stand alone system or network wide. An advanced processing and diagnostic module is included, again for use as an integral part of the system or as a stand alone analysis tool. Examples of the system's proposed data analysis and diagnostic abilities are also described using vibration signals as would be provided by the bearing module. (Author)
The emergence of new power electronics and improved battery technology has created renewed interest in Battery Energy Storage Systems (BESS). These new systems provide electric utilities with alternatives to conventional storage technologies, such as pumped hydro. BESs has the potential to provide substantial benefits in terms of energy management, improved voltage, spinning reserve and protection from interruptions when compared to large centralized storage. This paper describes a commercial, economically justified, application of the new Battery Energy Storage Systems which is presently under construction in the Metlakatla Power and Light system. The paper outlines the system performance requirements which lead to consideration of BESS as an option; the economic factors which provided the justification for BESS as an economic alternative; and the overall BES ...
The objective of this study is to establish a construction plan for vibration analysis system of HANARO's rotating machinery. To achieve this purpose, as a first step, the references related to the vibration analysis system for the rotating machinery were investigated. In addition, to verify the possibility of condition monitoring of the pumps, vibration signals obtained from the vibration monitoring system were analyzed. The results show that using the accelerometers mounted on the bearing locations of the pumps can monitor the current status of the pump such as unbalance, misalignment, and bearing condition. Based on the results of this study, the construction plans for the vibration analysis system of HANARO have been established. The hardware of the vibration analysis system will be installed by the end of this year. It is expected that the developed vibration analysis ...
Tarapur Atomic Power Station Unit-3 and 4 (TAPS -3 and 4) are the 540 MWe reactors. Unit-4 attained first criticality on 06th March 2005 and operated for about 230 effective full power days (EFPD). Unit-3 attained first criticality on 21st May 2006 and operated for about 20 EFPD. With the reactor operation radiation field increases on the Primary Heat Transport system equipments, Moderator system equipments and auxiliary system equipments due to deposition of fission products and activation products in different reactor systems. These dose rates significantly contributes to the external exposure and stations collective dose during reactor operation, refueling operation and maintenance activities. A study was undertaken at TAPS 3 and 4 to identify the system equipments showing the significant dose rates and identify the radionuclides present in the primary heat transport ...
This report contains the operation procedures in extreme situations and lessons learned from blackouts, based on a mandate given by the Operations Committee. Nordic TSOs have had common rules and principles for system operation i.e. System Operation Agreement since the late 1990s. The rules have been revised according to the system security and market changes and needs. The collaboration between system operators is regular and fruitful. The knowledge and capability to manage extreme situations of the Nordic power system has continuously increased and the recent blackouts did not show major deficiencies in operation practices. Regardless of the existing good collaboration it is important to continue development in the future in order to ensure high system security. Important development areas are security of reserve supervision and coordination of calculation ...
This report describes accomplishment of simulations of Pyrochemical Process Operation by using virtual engineering models. The pyrochemical process using molten salt electrorefining would introduce new technologies for new fuels of particle oxide, particle nitride and metallic fuels. This system is a batch treatment system of reprocessing and re-fabrication, which transports products of solid form from a process to next process. As a results, this system needs automated transport system for process operations by robotics. In this study, a simulation code system has been prepared, which provides virtual engineering environment to evaluate the pyrochemical process operation of a batch treatment system using handling robots. And the simulation study has been conducted to evaluate the required system functions, which are the function of handling ...
During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to ...
A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered ...
Embedded systems have become integral parts of a diverse range of systems from automobiles to critical infrastructure applications such as gas and electric power distribution. Unfortunately, research on computer security in general and intrusion detection in particular, has not kept pace. Furthermore, embedded systems, by their very nature, are application specific and therefore frameworks for developing application-specific intrusion detection systems for distributed embedded systems must be researched, designed, and implemented. In this paper, we present a configurable middleware-based intrusion detection framework. In particular, this paper presents a system model and a concrete implementation of a highly configurable intrusion detection framework that is integrated into MicroQoSCORBA, a highly configurable middleware framework developed for embedded ...
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node ...
The theory and application of the optimal control of linear systems to stabilize or improve the system stability is well known. For an optimal linear regulator design, the arbitrariness involved in the parameters of the cost function always affects the final control law and the closed-loop system poles which decide the system dynamic characteristics. A new approach, 'The inverse problem approach' has been developed to overcome this difficulty. The system so designed will have preassigned closed-loop poles and the resulting closed-loop system performance can be ensured. In this paper the inverse problem approach for optimal regulator design is applied to the power system stabilizer (PSS) design for single-machine infinite-bus systems. The results show that, as far as the linearized model is concerned, ...
Solid polymer fuel cell (SPFC) systems are compared to spark ignition (SI) engine power systems for utility vehicle applications. Utility vehicles provide crew and payload transport and electrical power at work sites lacking grid supply. The methodology emphasizes comparison on an equal service basis. Using power system component models and numerical analysis, power systems are designed using SI engine and SPFC technologies. The power systems are compared on the basis of fuel energy consumed and life cycle cost (LCC). Gasoline is the fuel for the SI engines, while liquid hydrogen is used for the SPFC. Three types of SPFC power system configurations are studied. The superior SPFC in terms of LCC is a fuel cell/battery hybrid where the fuel cell is sized to provide average driving power. Using today's technology, SPFC power systems ...
The Wind2H2 system is fully functional and continues to gather performance data. In this report, specifications of the Wind2H2 equipment (electrolyzers, compressor, hydrogen storage tanks, and the hydrogen fueled generator) are summarized. System operational experience and lessons learned are discussed. Valuable operational experience is shared through running, testing, daily operations, and troubleshooting the Wind2H2 system and equipment errors are being logged to help evaluate the reliability of the system.
Small electrical demand supply systems, to serve small communities close to high voltage transmission lines, have been examined to delineate their technical and economic characteristics. Parameters to measure system performance were outlined. Development of the Brazilian version of the Energy Overhead Ground Wires (EOHGW) system was described. This system has been supplying electricity to Rondonia and Mato Grosso states in central and northern Brazil, Operating experiences with this system were reviewed. 4 refs., 8 tabs.
A catalytic trap oxidizer based on a radial flow metal mesh filter was developed for use as an after treatment device on light-duty diesel vehicles. A complete system for assisted regeneration was devised to enable this unit to operate without blocking during all normal driving modes. The integration of the catalyzed trap and regeneration system with the vehicle to provide a practical system for the reduction of diesel particulate emissions is discussed. To date, many prototype catalytic trap and regeneration system installations have been completed on various test vehicles, both naturally aspirated and turbocharged. The operational conditions and test results from a selection of these studies are presented.
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
The Office of Civilian Radioactive Waste Management (OCRWM) is executing a plan for improvement of the United States Nuclear Waste Management Program. As part of the plan, OCRWM is performing a systems engineering analysis of both the physical system, i.e., the Nuclear Waste Management System (NWMS), and the programmatic functions that must be accomplished to bring the physical system into being. The functional analysis effort is being performed by two separate teams working in parallel, one of which addresses the physical system functions and the other the programmatic functions. This paper presents information on the analysis of the programmatic functions.
In this paper, power system stabilizer design for multi-machine power systems is translated into an equivalent problem of decentralized controller design for Multi-Output Multi-Input (MIMO) control systems. Subject to a condition based on the structured singular values, each stabilizer can be designed independently. Within this general framework, the conventional stabilizer design methodology based on the concept of synchronous and damping torques is used to decide the design details of each stabilizer. The suggested design method is applied to a model of a practical 10 machine power system. (author)
In this paper, it is suggested that the selection method of optimal parameter of power system stabilizer (PSS) with robustness in low frequency oscillation for power system using real variable elitism genetic algorithm (RVEGA). The optimal parameters were selected in the case of power system stabilizer with one lead compensator, and two lead compensator. Also, the frequency responses characteristics of PSS, the system eigenvalues criterion and the dynamic characteristics were considered in the normal load and the heavy load, which proved usefulness of RVEGA compare with Yu's compensator design theory. (author). 20 refs., 15 figs., 8 tabs.
This paper presents the eigenvalue control strategy which utilizes an adaptive power system stabilizer for the decentralized control of damping and frequency of electromechanical oscillations in power systems. The control procedure includes the complete identification of the decoupled subsystem model in real-time from local measurements only and the assignment of its estimated electromechanical eigenvalue by the change of stabilizer parameters. The robustness and efficiency of the proposed adaptive controller to enhance overall system stability are illustrated in several examples, including the three-machine power system model.
This paper presents a novel design methodology, based on shaping the system frequency response, for the generation of an appropriate residual signal that is sensitive to sensor faults in the presence of model uncertainty and exogenous unknown (unmeasured) disturbances. An integrated feedback controller design and robust frequency-based fault detection approach is proposed for Single-Input/Single-Output systems. The effciency of the proposed method is demonstrated on a Single Machine Innite Bus (SMIB) power system that achieves a coordinate power system stabilizer with satisfactory sensor fault detection capabilities.
The Meteorological Information System (MIS) comprising the meteorological instruments, the computers, and the software for data processing and recording, is part of the KfK safety and control system. In 1982 is was equipped with an independent data processing system. The report explains the arrangement and the operation of the sensors and thw two process computers. For selected meteorological situations the ability of the system is demonstrated, i.e., the presentation of the vertical profiles of wind, temperature and turbulence in the lower atmospheric boundary layer as well as the calculation and graphical representation of the transport and dispersion into the KfK environment of radioactive pollutants being released by the nuclear installations of the KfK into the atmosphere.
Many rural industries generate amounts of biomass waste, such as rice husks, sawdust, wood chips, nutshells and plant stalks that represent a substantial energy resource. However, most often these biomass wastes are not utilized and are dumped or burned in the open. This paper will show the whole project cycle of an installation and commissioning of a thermal configuration of a BG-Systems in Indonesia. These projects highlight the economic, operational and environmental benefits of the BG-Systems. BG-Systems are small fixed-bed downdraft gasifier systems being marketed by BG Technologies that convert biomass into a producer gas that is essentially free of tars and can be used reliably in a diesel engine or thermal combustor. (author)
The existence of a global attractor for the solution semiflow of the extended Brusselator system in the $L^2$ phase space is proved, which is a cubic-autocatalytic and partially reversible reaction-diffusion system with linear coupling between two compartments. The method of grouping and re-scaling estimation is developed to deal with the challenge in proving the absorbing property and the asymptotic compactness of this typical multi-component reaction-diffusion systems. It is also proved that the global attractor is an $(H, E)$ global attractor with the $L^\\infty$ regularity and that the Hausdorff dimension and the fractal dimension of the global attractor are finite. The results and methodology can find many applications and further extensions in complex biological and biochemical dynamical systems.
This manual is intended to provide a guide to the use of the Flue Gas Desulfurization Information System (FGDIS) data base which is a collection of data files consisting of information pertaining to the design and performance of flue gas desulfurization (FGD) systems. The files are stored at the U.S. Environmental Protection Agency National Computer Center (NCC), Research Triangle Park, NC. Access to these files and manipulation of the data therein is accomplished via System 2000, general data base management system developed by INTEL Corp. and supported by the NCC Univac 1100 hardware.
We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.
The purpose of this project is to integrate a variety of geographic information systems capabilities and telecommunication technologies for potential use in geographic network and visualization applications. The specific technical goals of the project were to design, develop, and simulate the components of an audio/visual geographic communications system to aid future real-time monitoring, mapping and managing of transport vehicles. The system components of this feasibility study are collectively referred to as a Geographic Visualization and Communications System (GVCS). State-of-the-art techniques will be used and developed to allow both the vehicle operator and network manager to monitor the location and surrounding environment of a transport vehicle during shipment.
The common envelope phase of binary star evolution plays a central role in many evolutionary pathways leading to the formation of compact objects in short period systems. Using three dimensional hydrodynamical computations, we review the major features of this evolutionary phase, focusing on the conditions that lead to the successful ejection of the envelope and, hence, survival of the system as a post common envelope binary. Future hydrodynamical calculations at high spatial resolution are required to delineate the regime in parameter space for which systems survive as compact binary systems from those for which the two components of the system merge into a single rapidly rotating star. Recent algorithmic developments will facilitate the attainment of this goal.
Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)
Use of a broadband Local Area Network (LAN) for transmission of classified and secure unclassified information requires monitoring capabilities which are sensitive to discrete segments of the network frequency spectrum. A viable monitoring system must be capable of detecting possible intrusion attempts or network malfunctions and alerting operating and security personnel. This report documents the results of an evaluation of the Magnavox CATV Systems Inc. Digital System Sentry software for network monitoring. Recommendations are made on its possible future role in broadband LAN security monitoring throughout the Nuclear Weapons Complex.
Control of pressure transients in a hydraulic system may be important and necessary to avoid failures and to improve the efficiency of operation. Flow restricting devices can result in a decrease in the peak pressure, but may change the response time. The response time has an important effect on both operator and operator perceived smoothness. The response time should correspond to how fast a system responds to a given disturbance at the system boundary. Occasionally the appropriate response time is not easily determined. This study is on the response time characteristics in the hydraulic system studied for the control of response time.