WorldWideScience
 
 
1

III International Symposium on analytical methodology in the Environment. III Symposium Internacional de Metodologia Analitica en el campo del medio ambiente  

Energy Technology Data Exchange (ETDEWEB)

The symposium had four areas in analytical methodology to study global environmental change: air; water, wastes and speciation, analytical methodology and environmental management. The symposium had 24 conferences and papers.

1994-01-01

2

Kinetics of the methylparathion hydrolysis in aqueous medium; Cinetica de la hidrolisis del metilparation en medio acuoso  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of alkaline hydrolysis of methylparathion was studied at different temperatures (0-50 Centigrade) in the p H range of 8-12 by ultraviolet-visible absorption spectroscopy. Optimum p H and wavelength conditions were defined to carry out the simultaneous determination of methylparathion and one of its hydrolysis product, paranitrophenol, in buffered aqueous medium. Based on the experimental data and the mathematical equation of the kinetics, a rate constant (k) of first-order and an activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author) activation energy (Ea) of 9.2 Kcal/mol, were estimated. (Author)

1997-12-31

3

Rational protection of the quality of coastal waters by means of integrated, real-time management of the water environment; Proteccion racional de la calidad de las aguas costeras mediante la gestion integrada y en tiempo real del medio hidrico  

Energy Technology Data Exchange (ETDEWEB)

Before the implementation Water Framework directive, it was usual to forget that a good environment protection of the receiving waters needs a correct and coordinated operation of the subsystems of the water cycle, specially sewerage system, WWTP and receiving waters. This explains that most of the countries have focused their efforts in the treatment of dry weather flows forgetting the management of wet weather flows. Actually the idea that a sewerage system or a WWTP can not be planned or managed independently without considering the effects on the receiving waters is commonly accepted because not only each one of these systems must work correctly but also it is required a minimum impact in the receiving waters of the sewerage and WWTP overflows in dry and wet weather. All these links will affect the management strategy of the sewerage system (storm water detection tanks, gates, pumping stations, etc)., the interceptor, the WWTP and the receiving waters. Only an integral planning of ...

2005-07-01

4

Interleukin-8 Expression in Lung Tissue During Ischemia-Reperfusion  

British Library Electronic Table of Contents (United Kingdom)

Objetivo La generacion local de citocinas es un factor patogenico en el dano por isquemia-reperfusion en la disfuncion precoz del injerto. Este estudio analiza la expresion en tejido pulmonar de ARN mensajero de interleucina-8 (ARNm de IL-8) y su relacion con los cambios intersticiales pulmonares en un modelo experimental de isquemia-reperfusion pulmonar normotermica. MATERIAL Y METODOS Se estudiaron 16 conejos de la raza Nueva Zelanda en 3 grupos de estudio: a) basal; b) isquemia (lobulo inferior derecho tras isquemia de 1, 2 o 3 h), y c) reperfusion (lobulos superior y medio derechos tras 1 h de isquemia y 1, 2 o 3 h de reperfusion). Se deter- mino la expresion del ARNm de IL-8 mediante transcripcion inversa y reaccion en cadena de la polimerasa y estudio la infiltracion intersticial por...

2007-01-01

5

Geothermal energy in Italy and abroad; La geotermia in Italia e all'estero  

Energy Technology Data Exchange (ETDEWEB)

Geothermal systems and fields are analysed giving particular evidence to the value of the geothermal source as an important natural source of energy. The paper analyses hydrothermal systems and describes the international experimental studies on the use of geothermal reservoirs in hot rocks with geopressured and magmatic systems. Experts are optimistic as far as the use of this innovative source of energy is possible in the medium-short term. [Italian] Si analizzano i sistemi e i campi geotermici, sottolineando il valore della fonte geotermica come risorsa naturale ragguardevole d'energia. Vengono descritti i sistemi idrotermali e gli esperimenti condotti a livello internazionale sull'utilizzo di serbatoi geotermici in rocce calde con sistemi geopressurizzati e magmatici. L'ottimismo degli esperti sull'utilizzo di questa innovativa sorgente d'energia in tempi medio-brevi.

2001-04-01

6

Determination of the hydrolysis constants of Europium (III), in ion strength media 4, 5 and 6 M NaClO{sub 4} at 303 K; Determinacion de las constantes de hidrolisis del Europio (III), en medios de fuerza ionica 4, 5 y 6 M de NaClO{sub 4} a 303 K  

Energy Technology Data Exchange (ETDEWEB)

This work was made with the purpose to complete information about the hydrolysis constants of Europium (III) in high ion strength media. So it was determined at a ion forces media 4, 5 and 6 M of sodium perchlorate at 303 K. The method used was the potentiometric with the aid of the Super quad computer program. In high ion strength media, the measurements of p H do not correspond directly to negative logarithm of the concentration of hydrogen ions, by this it is necessary to calibrate the electrode in these conditions. The Europium was hydrolized at pC{sub H} values greater 6 in all cases. The potentiometric method used under the described experimental conditions is adequate to determine the hydrolysis constants of Europium (III). According to the results and diagrams of chemical species of Europium obtained we can conclude that the hydrolysis constants, differ by its distribution but not in its identity. (Author)

1999-07-01

7

Comparative study of the electrochemical behaviour of iron in alkaline media containing red mud and grey slurries. the effect of Al{sup 3}+; Estudio comparativo del comportamiento electroquimico del hierro en medio alcalino en presencia de lodos rojos y lodos grises. Efecto del Al{sup 3}+  

Energy Technology Data Exchange (ETDEWEB)

Red mud (Rm) is the main by-product of the Bayer process for alumina extraction from bauxite, and grey slurries (GS) are generated during the granite rocks transformation processes. the huge volume of those wastes generated every year suppose a serious environmental problem. Recent works by our group demonstrate the efficiency of both types of muds as corrosion inhibitors for iron and steel in alkaline media containing chlorides. The elemental analysis of these slurried shows that Al{sup 3}+ is the main common element. Therefore, the aim of this paper is to study the effect of the soluble Al{sup 3}+ in the electrochemical behaviour of iron in alkaline media, in presence and absence of chlorides. The electrochemical study using Cyclic Voltammetry (CV) and Electrochemical Impedance Spectroscopy (EIS) together with surface analysis techniques allowed to conclude that Al{sup 3}+ blocks the surface of steel in alkaline media chloride increasing the steel resistance to chlorides attack. ...

2009-07-01

8

Environmental management; La gestione ambientale  

Energy Technology Data Exchange (ETDEWEB)

Nowadays, unlike in the past, companies have to operate in a context of sustainable development, in which the economic and social development, production and consumption have to take into account the medium and long term impact on environment. The article sets forth some considerations about these subjects, which are assuming a growing importance in the management of companies: the variable environment may for instance be a factor of discrimination between being competitive or not. In order to characterise the context within which the environmental management has to be applied, some basic concepts about environmental management systems, Life Cycle Assessment, and Eco labeling are illustrated. As an example of application of the methodology described, a brief reference to the Italgas Group Environmental Report is given. [Italian] Oggi, a differenza del passato, le imprese si trovano ad operare in un contesto di sviluppo sostenibile, nel quale l'evoluzione economica e sociale, ...

2000-04-01

9

First assessment of low- to medium-temperature geothermal reserves in 20 Mexican states; Primera estimacion de las reservas geotermicas de temperatura intermedia a baja en veinte estados de Mexico  

Energy Technology Data Exchange (ETDEWEB)

A first, partial, assessment is included of the low- to medium-temperature geothermal reserves in 20 Mexican States and their aggregate value. The assessment covers about 29.16% of the identified geothermal-surface manifestations in the public database. For reserve assessments, we use the volumetric method, supplemented with Montecarlo simulations and statistics, to quantify inherent uncertainties. Our estimations are presented on a state-by-state basis. We estimate the aggregated reserves of the 20 states as between 7.7 x 1016 and 8.6 x 1016 kJ, with 90% confidence. The most likely reservoir temperatures range between 60-180 degrees Celsius, with a mean of 111 degrees Celsius. Such massive amounts of recoverable energy-and the associated temperatures-are potentially important for the economic development of nearby localities and the nation. [Spanish] En este trabajo se hace una primera estimacion, parcial, de las reservas geotermicas de temperatura intermedia a baja de Mexico. La ...

2009-07-15

10

Voltage and reactive power control by means of static compensators of vars in electric power systems; Control de voltaje y potencia reactiva mediante compensadores estaticos de Vars en sistemas electricos de potencia  

Energy Technology Data Exchange (ETDEWEB)

In this thesis a study is made of the of voltage characteristics and reactive power control in the transmission network of the Electric Power Systems (EPS) with static compensators of VARs (SCVs). The necessity of voltage and reactive power control and the application of SCVs as a solution means for three representative operation stages of the EPS, considering balanced operation conditions and fundamental frequency is analyzed: Operation in the presence of incremental voltage changes, quasi-stationary operation or steady state and behavior at the occurrence of big disturbances. The application of SCVs to systems of integral transmission is in general a closed loop control system, reason why the analysis of the interaction of the system EPS-SCV is considered as an essential part of the voltage and reactive power control study. Firstly, the response analysis of the control loop is made for incremental voltage changes, representing the power system by means of its equivalent of Thevenin ...

1987-07-01

11

Importance of the planning activities, cutting, handling and analysis of the nuclei of oil well drilling; Importancia de las actividades de planificacion, corte, manejo y analisis de los nucleos de perforacion de pozos petroleros  

Energy Technology Data Exchange (ETDEWEB)

In the geologic formation where the oil deposits are located, diverse types of rocks perform functions as structural elements, storage containers for hydrocarbon water and calorific energy, as well as impermeable barriers and transport means of the energy and the fluids. Among the most important properties that are used to describe these functions are the porosity, the permeability, the compressibility of the pores volume, the formation resistivity factor, the saturation exponent, the velocity of acoustic waves P and S, the relative permeability, the capillary pressures, the elastic constants and other mechanical properties, the thermal expansion, coefficient, the thermal conductivity, the thermal diffusivity and the specific heat. The execution of an ample variety of activities related to the stages of exploration, location, evaluation and development of the oil deposits, depends strongly on having a good knowledge of the magnitude and the spatial variability of these properties. The ...

2007-07-01

12

Liver trauma from penetrating injuries. Miscellanea, personal series, clinical and CT findings; Traumi epatici da lesioni penetranti. Miscellanea, casistica personale, aspetti clinici e con Tomografia Computerizzata  

Energy Technology Data Exchange (ETDEWEB)

Penetrating liver wounds are related to many causes and rank second after blunt abdominal and liver trauma. In this report are examined the clinical and radiological findings of personal series of patients with penetrating trauma, especially by firearms and stab and cut wounds. It will also tried to define the diagnostic workup of these traumas, which is especially based on CT signs of liver damage and associated changes and which is of basic importance for following treatment, both surgical or conservative. In the last seven years it was retrospectively reviewed 31 cases of penetrating liver trauma. The patients were 19 men and 12 women, ranging in age 18 to 73 (mean 42), with penetrating liver injuries from firearms (16 patients) and stab (9 cases) wounds; 6 patients had injuries from different cases. Abdominal CT was carried out in emergency with the CT Angiography (CTA) technique in all patients. In the patients with suspected chest and abdomen involvement CT was performed from the ...

2000-12-01