Oil and gas resources in the offshore areas of the US constitute a significant portion of US recoverable hydrocarbon resources. The exploration, development and production of these offshore resources in California, however, could have significant airquality implications for coastal air basins. This study was developed to address a problem that frequently arises with offshore airquality assessments. Typically, such assessments are performed for a specific activity scenario (e.g., a Federal OCS Lease Sale involving a projected number of drilling rigs, platforms, pipelines, etc.) and assume a projected (but uncertain) level of recoverable oil and gas resources. This study enables interested parties to estimate air emissions and impacts for a wide range of OCS-related development scenarios. The modular emission calculation procedure and the ...
Those areas in California where synthetic fuel-fired power plants could be sited in the 1990 time frame, from an airquality perspective were identified. The synfuel-fired power plants considered in this new study were 500 MW methanol-fired combined cycle (MFCC) and 500 MW integrated gasifier combined-cycle (IGCC) units. For comparison purposes, 500 MW direct coal-fired boilers and 500 MW natural gas-fired combined-cycle units were also considered. The study provides an approximation, for planning purposes, of a reasonable limit of the state's power plant siting capacity, given the plant types and sizes, conditions, and assumptions specified. The study shows that local emission limitations many times preclude certain types of power plants even when they are equipped with Best Available Control Technology (BACT) as required by NSR regulations. This study also shows that 4000 MW of direct-fired coal plants could ...
The object of this study was to identify those areas in California where synthetic fuel-fired power plants could be sited in the 1990 time frame, from an airquality perspective. The synfuel-fired power plants considered in this new study were 500 Mw methanol-fired combined cycle (MFCC) and 500 Mw integrated gasifier combined-cycle (IGCC) units. For comparison purposes, 500 Mw direct coal-fired boilers and 500 Mw natural gas-fired combined-cycle units were also considered. Staff did not attempt to locate plants at any specific sites, but relied primarily upon a regional countywide analysis. The study provides an approximation, for planning purposes, of a reasonable limit of the state's power plant siting capacity, given the plant types and sizes, conditions, and assumptions specified. The study shows that local emission limitations often preclude certain types of power plants (particularly direct-fired coal plants) ...
BackgroundHeterogeneous results for research investigating health-related quality of life (HRQL) in patients undergoing sphincter-ablating procedures for rectal cancer...Full Text Available
Room airquality and thus thermal comfort for the occupiers in closed spaces depend on several factors: temperature and humidity of the air, temperature of the surrounding surfaces, content of foreign matter of the air, acoustical perceptions, electric fields and ions as well as colours and light. Air humidification, cleaning and ionization largely contributes to improved room airquality. The article goes into problems of too dry and polluted air as well as into measures with which these problems can be solved. (BWI).
...AirQuality Monitoring Networks Products and Equipment Find and compare a variety of airquality monitoring networks products and equipment on the world's largest environmental industry portal. ...
BackgroundIntegration of medical care across clinicians and settings could enhance the quality of care for patients. To date, there is limited data on the levels of integration in...Full Text Available
Intensive measurements of organic acids, inorganic acids, aldehydes and peroxyacetyl nitrate (PAN) in urban air were carried out at a Southern California smog receptor site, Glendora, CA, August 12-22, 1986. The objective of this project was to augment the data base regarding organic acids in urban air and to assess their role with emphasis on ambient levels, diurnal variations, phase distribution, emissions, in-situ formation and removal. The relative abundance of organic acids and inorganic acids was determined for the first time from simultaneous measurements carried out during this study.
Expedited site characterization (ESC), developed by Argonne National Laboratory, is an interactive, integrated process emphasizing the use of existing data of sufficient quality, multiple complementary characterization methods, and on-site decision making to optimize environmental site investigations. The Argonne ESC is the basis for the provisional ESC standard guide of the ASTM (American Society for Testing and Materials). QuickSite{sup SM} is the implementation package developed by Argonne to facilitate ESC of sites contaminated with hazardous wastes. At various sites, Argonne has successfully implemented QuickSite{sup SM} and demonstrated the technical superiority of the ESC process over traditional methodologies guided by statistics and random-sampling approaches. A key feature in the success of QuickSite{sup SM} investigations is achieving an understanding of the subsurface geologic and hydrogeologic controls and processes at a site before extensive sampling ...
The technique of air diffusion by shifting presents several advantages in terms of thermal comfort, indoor airquality and energy conservation. This book presents the principle, dimensioning, and implementation of air shifting diffusion systems. (J.S.)
A statistical method is developed to determine the locations of major pollutant sources affecting a distant downwind receptor, provided that air trajectories can be estimated. Probability density functions are estimated which indicate the overall residence time of air parcels over a given geographic region as they travel toward a receptor and residence time for the case of high pollutant concentrations at the receptor. These functions are used to estimate a conditional probability function which indicates the potential for a source region to contribute to high air pollution concentrations. Finally, a source contribution function is formulated to indicate the relative contribution of different source regions to high concentrations at the receptor. The method is tested using data collected at Grand Canyon National Park in 1980. The dominant pathway for air masses arriving at Grand Canyon during this ...
Electric cars have long been seen as science fiction. This may be changing. As the 1990s began, several companies chose to launch publicity campaigns for electric vehicles. In California, experimental programmes are gaining momentum, in the context of LA's appalling air pollution problems and tightening clean air standards. Supporters claim that electric motive power is a key to solving several environmental problems involving atmospheric pollution. These claims are examined. (author).
The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and airquality, evaluation of the ventilation. figs., tabs., refs.
In order to promote the use of natural gas air-conditioning systems in the tertiary sector, Gaz de France (the French gas utility) in association with Electricite de France (EdF) and the French chamber of council engineers (CICF) have created the Acerclim organization which aims at certifying the quality of the design, realization and exploitation of air processing and air-conditioning installations according to the ISO 9001 criteria. This article describes this quality procedure named 'CHSB Air'. (J.S.)
A new prototype model system named AirGIS has been developed to support local authorities in airquality management for big Danish cities. The system is based on the Danish operational street pollution model (OSPM), technical and cadastral digital maps and Danish national administrative databases on buildings, cadastres and populations. It applies a geographic information system (GIS). AirGIS estimates ambient air pollution levels at high temporal and spatial resolutions. The model system enables mapping of traffic emissions, airquality levels and human exposures at residence addresses, at workplace addresses and in streets. Mapping and scenario results can be compared with airquality limits. Impact assessment of traffic air pollution abatement measures can also be carried out. ...
...of stations and a number of components, and meta information on airquality monitoring networks and stations. Access the database Producer Europe Environment Agency Content ...of stations and a number of components, and meta information on airquality monitoring networks and stations. Coverage National (Europe) Number of records...
IAQ Tools for Schools Program Leaders in Improving Indoor AirQuality in Schools Baldwin Union Free School District, Baldwin, NY El Paso Independent School District, El Paso,...
In the San Joaquin River Basin, California, a realtime water quality forecasting model was developed to help improve the management of saline agricultural and wetland drainage to meet water quality objectives. Predicted salt loads from the water quality forecasting model, SJRIODAY, were consistently within +- 11 percent of actual, within +- 14 percent for seven-day forecasts, and with in +- 26 percent for 14-day forecasts for the 16-month trial period. When the 48 days dominated by rainfall/runoff events were eliminated from the data set, the error bar decreased to +- 9 percent for the model and +- 11 percent and +- 17 percent for the seven-day and 14-day forecasts, respectively. Constraints on the use of the model for salinity management on the San Joaquin River include the number of entities that control or influence water quality and the lack of a centralized authority to direct ...
... The colored background is an isopleth map showing change in sulfate concentrations as measured by the CASTNET rural airquality monitoring network , leading to significant improvements in airquality and human health. Wet sulfate deposition decreased 43 percent in the Northeast and 44 percent in the ...
Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor airquality as thermal comfort in the rooms occupied by different number of persons. (GL)
The measurement of air pollutants is no more sufficient. It is necessary to assess the risk induced by air pollution, and then to put in place actions to reduce it. The airquality monitoring takes into account different pollutants: nitrogen oxides, carbon monoxide, particulates for the traffic; sulfur dioxide and particulates for use of fuel or coal or chemical transformations in air; ozone and nitrogen dioxide from hydrocarbon and nitrogen oxides emissions; the use of simulation methods allow to calculate the concentrations levels for these pollutants taken as indicators. (N.C.)
This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, airquality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, airquality and energy use following selection of control parameters for controlling air masses.
This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor airquality; the main themes are: indoor airquality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, airquality, thermal comfort and ventilation-induced acoustic levels
The results of radon concentration measurements in the near surface air at San Nicolas Island, California, are presented for five different measurement sessions between May 1978 and July 1980. Emphasis is on the previously unreported results for January and July 1980. For six of eight days during the January session the measured radon concentration was greater than 40 picocuries per cm, corresponding to a continental air mass. Only the first day involved a maritime air mass with radon concentration less than about 6 picocuries per cm. In contrast to all the previous sessions, maritime air dominated the ten day session in July 1980, with radon concentrations generally less than about 5 picocuries per cm.
This Final Environmental Impact Statement and Environmental Impact Report (Final EIS/EIR) has been prepared to meet the requirements of the National Environmental Policy Act (NEPA) and the California Environmental Quality Act (CEQA). The Proposed Action includes the construction, operation, and decommissioning of a 48 megawatt (gross) geothermal power plant with ancillary facilities (10-12 production well pads and 3-5 injection well pads, production and injection pipelines), access roads, and a 230-kilovolt (kV) transmission line in the Modoc National Forest in Siskiyou County, California. Alternative locations for the power plant site within a reasonable distance of the middle of the wellfield were determined to be technically feasible. Three power plant site alternatives are evaluated in the Final EIS/EIR.
A three-component seismic line acquired over the Zamora gas field, northern Sacramento Valley, California, displays conventional (P-P) and converted-wave (P-SV) seismic anomalies. Well log and seismic modeling results indicate that bright-spot reflection strengths are related to variations in fluid saturation and lithology. The P-SV reflection strengths and interval velocities provide valuable information that complements more conventional strategies such as amplitude with offset and polarity analysis. This integrated strategy can improve risk evaluation and well-site selection in areas where rapid changes in reservoir quality impact resource evaluation.
A three-component seismic line acquired over the Zamora gas field, northern Sacramento Valley, California, displays conventional (P-P) and converted-wave (P-SV) seismic anomalies. Well log and seismic modeling results indicate that bright-spot reflection strengths are related to variations in fluid saturation and lithology. The converted-wave reflection strengths and interval velocities provide valuable information that compliments more conventional strategies such as amplitude with offset and polarity analysis. This integrated strategy can improve risk evaluation and well site selection in areas where rapid changes in reservoir quality impact resource evaluation.
Availability of a natural gas-powered van that meets California`s ultra low emission vehicle requirements and has a 300-km range was reported. A similar van with an electric system giving a range of 240 km was also within sight. Regarding the limitations of electric batteries it was suggested that a super capacitor may allow systems to achieve higher energy densities; a refuelable zinc-air battery could be considered for vehicle use. While the prospect for emissions improvement of gasoline vehicles has clearly improved in recent years, the relative costs of infrastructure, vehicle and fuel for the the alternative fuels compared with gasoline demonstrate the difficulty the alternative fuels have in taking market share from gasoline. For the next decade, gasoline, propane and CNG are expected to be the dominant fuels for vehicles. After that, the leading fuel will be the one that has been most extensively researched and developed during the ...
Within the framework of the IEA project Annex 20 - Airflow patters within buildings , an airflow data base was built up as a prototype. It enables airflow profiles, comfort and interior airquality to be studied without having to carry out a 1:1 experiment or having to run an expensive simulation code. The data base contains a number of pre-calculated room airflow profiles with their associated depictions of airquality and risks of drafts for given premises and for different ventilation systems. figs., tabs., refs.
There is a well-known story about the blind man examining the elephant: the part of the elephant examined determines his perception of the whole beast. Perhaps bioinformatics--the shotgun marriage between biology and mathematics, computer science, and engineering--is like an elephant that occupies a large chair in the scientific living room. Given the demand for and shortage of researchers with the computer skills to handle large volumes of biological data, where exactly does the bioinformatics elephant sit? There are probably many biologists who feel that a major product of this bioinformatics elephant is large piles of waste material. If you have tried to plow through Web sites and software packages in search of a specific tool for analyzing and collating large amounts of research data, you may well feel the same way. But there has been progress with major initiatives to develop more computing power, educate biologists about computers, increase funding, and set standards. For our ...
To predict airquality properly at a given location, it is necessary to identify all emission sources that will have significant impact at that location. Furthermore, the atmospheric pollutants that are emitted by these sources must be identified and quantitatively characterized. Once the air-quality predictions have been made, it is desirable to have some historical air-quality data for comparison. An efficient means of obtaining this information is through the use of detailed emission inventories and an inventory of air-quality-monitoring stations. Therefore, as part of the Alberta Government/Industry Acid Deposition Research Program (ADRP), three comprehensive inventories have been developed, namely: a sulfur dioxide (SO/sub 2/) emission inventory, a nitrogen oxides (NOx) emission inventory, and an inventory of air-quality-monitoring stations. Volume 2, ...
This paper reports thermal comfort and indoor airquality (IAQ) studies of an under-floor air-conditioning (UFAC) system in a hot and humid climate. Thermal comfort parameters were measured at pre-determined grid points within an imaginary plane to predict the air flow pattern of the supply air jet as well as to determine the occurrence of thermal stratification in the office space. Fanger's thermal comfort index was also computed to detect the occupants' thermal sensation. Besides, the concentration levels of dust and carbon dioxide were recorded with the intention to examine the quality of the indoor air. Statistical methods were applied to derive the relationship between air velocity and the other parameters as mentioned earlier. The main findings from the study revealed reasonable level of ...
The report presents a long-range plan for a broad-based, coordinated research, development and market transformation program for reducing the lighting energy intensities in commercial and residential buildings in California without compromising lighting quality. An effective program to advance lighting energy efficiency in California must be based on an understanding that lighting is a mature field and the lighting industry has developed many specialized products that meet a wide variety of light needs for different building types. Above all else, the lighting field is diverse and there are applications for a wide range of lighting products, systems, and strategies. Given the range of existing lighting solutions, an effective energy efficient lighting research portfolio must be broad-based and diverse to match the diversity of the lighting market itself. The belief that there is one solution--a magic bullet, such as a ...
This paper presents a multicriteria analysis of ventilation during summertime in Europe. Multicriteria analysis theories are used to determine the most suitable ventilation strategy on a university building, that is to say to ensure the best possible indoor airquality, thermal comfort of the occupants and the lower energy consumption in case of accelerated diurnal or nocturnal ventilation and/or air conditioning. After defining the possible actions, the criteria of quality regarding thermal comfort, indoor airquality and energy consumption are defined. The possible actions are then assessed relative to each of these three criteria and ranked from the best to the worst ones using two different multicriteria analysis methods. (author)
Programs & Services Technical Resources Land Use Soils Water Snow Survey & Water Supply Water Management Water Quality Watersheds Wetlands Air Plants & Animals Energy Climate...
People assess the quality of the air indoors primarily on the basis of its odors and on their perception of associated health risk. The major current contributors to indoor odorants are human occupant...Full Text Available
The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor airquality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)
In the 1988 February issue of this magazine the units olf and decipol were introduced. Olf is a measure for the pollution load and decipol for the indoor airquality. This article discusses a new ventilation theory which is quantified by the new indoor airquality thermal comfort balance based on the units olf and decipol. This balance requires more ventilation air than for the present regulations. It takes into account all pollution sources. 2 figs., 9 refs., 3 tabs.
This report provides information to government and industry to enable decision-making and management of local environmental quality conditions. The need for a summary airquality report has arisen in recent years due to growing concerns about airquality. Increased growth in population and the tourism industry is placing additional pressures on environmental quality. The report summarized meteorological and airquality data collected by the British Columbia Ministry of Water, Land and Air Protection in the Sea-to-Sky airshed from 1984 to 2001. The airshed is located in the Lower Mainland region of British Columbia. Airquality monitoring was conducted for various periods at 18 different stations and meteorological monitoring was conducted at 4 locations. A ...
Jet Propulsion Laboratory. California Institute of Technology. Pasadena, California. Energy and Water Conservation. Steve Rigdon. Facilities Energy Manager ...
The ventilation performance of cold-air distribution systems was investigated in a full-scale test room for three different designs of ceiling-mounted diffusers: a large square radial, a small square radial, and two linear diffusers. The supply air temperature was 38 F (3.3 C). Tests were conducted with internal heat loads and with and without furnishings. The local mean ages of air, air diffusion effectiveness, and contaminant-removal efficiency were measured using tracer gas techniques to assess the performance of the ventilation system in maintaining adequate airquality conditions in the occupied region. Air velocities and temperatures were also measured in the occupied region to calculate the air diffusion performance index (ADPI). It was found that the cold-air distribution system provided ...
Wildland fire suppression personnel employed by the CDF do not currently have the equipment to protect themselves from the short-term acute affects of smoke from wildland fires. In addition, no regulations exist that specify appropriate respiratory protection and the current air-purifying respirator technology and carbon monoxide monitoring has not been adapted to fit wildland fire suppression requirements. This three-year limited study evaluated the ability of wildland fire fighters to perform their normal job function while wearing full-face air-purifying respirators. In the first two years of this study we designed, developed and field tested a prototype ``smart`` air-purifying respirator which incorporated a real-time carbon monoxide monitor into a commercial full-face respirator.` Data on carbon monoxide exposure while fighting wildland fires was collected. During the third year of this study we evaluated eight ...
The MISR instrument aboard NASA's Terra satellite participated in the UAE-2 campaign, August-October 2004. This campaign represented a unique opportunity to study the complex aerosol situation in the Arabian Gulf region, in the context of a first-rate collection of aircraft and surface-based instruments, giving us the opportunity to do some groundbreaking satellite aerosol validation work. We aimed (1) to validate MISR aerosol retrieval results for dust and pollution particles over dark and light surfaces, and (2) to contribute regional maps of aerosol optical thickness (AOT) and particle micro-physical properties, giving spatial context to the field-instrument measurements, and moving toward a satellite-based regional aerosol climatology. The validation effort benefited from the combination of an instrumented aircraft and a regional network of surface-based sun photometers. We obtained high-quality sub-orbital data coincident with MISR overpasses on three days: ...
Until the concerns about indoor airquality (IAQ) reached a peak in the last five years, interior zones of office buildings were traditionally served with cooling-only shut-off variable air volume (VAV) boxes. Heat gains from lighting and equipment, in addition to those from occupants themselves, caused supply air quantities of 13 C to 15 C (55 F to 60 F) air to be sustained at rates on the order of 2.5 L/s per square meter (0.5 cfm per square feet), a rate that most designers at the time felt would provide a comfortable and well ventilated environment. More recently, the reduction in lighting loads, the use of cold air systems, and, most importantly, the concern that acceptable indoor airquality may not be maintained at low air flow rates, has led to a different solution in interior zones: the ...
The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and airquality
The Bavarian Agency for Environmental Protection (LfU) is monitoring the airquality is several bavarian regions. The daily and monthly data of concentration ration of sulfur dioxide, nitrogen oxides, carbon monoxide, ozone and other pollutants are published in yearly reports, most often as diagrams with further statistica information.
This report describes the data, assumptions, and methodology used in the airquality analysis for the 1984 High Altitude Report to Congress. Detailed descriptions of the strategies examined and the mobile source emission factors associated with each strategy are included in this report only by reference.
Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better airquality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)
The major inquiry of the political party 'Die Gruenen' touches all problems connected with air pollution. The Federal Government states that an extensive air pollution abatement program, i.e. the revision of existing regulations and implementation of new ones has been allowing the realization of all essential environmental aims originally headed for three years ago in the field of air pollution abatement. Achievements such as these will bring about another obvious improvement of the airquality of the Federal Republic of Germany in the coming years. The recent development of energy economy has also proved to be having an obivously positive effect on the environment and pollution abatement. (HSCH).
This report presents results of an airquality assessment program in northwestern Ontario. It includes data from communities where long term monitoring is conducted, mostly in urban areas and near industrial sources of air pollution such as mining, pulp and paper, and thermal power generation. Summaries are also presented of special studies in the Thunder Bay area. The monitoring program identifies pollution sources and assesses the results of pollution control measures. Data are included only on those contaminants routinely monitored in northwestern Ontario, including particulates, CO, NOx, ozone, SO[sub 2], total reduced sulfur, organic compunds, and heavy metals. Data from airquality and meteorological instruments are supplemented by vegetation, soil and snow sampling studies. 25 refs, 14 figs., 16 tabs.
An objective methodology is presented for determining the number and disposition of ambient air-quality stations in a monitoring network for the primary purpose of compliance with air-quality standards. The methodology utilizes a data base with real or simulated data from an airquality dispersion model for application with a two-step process for ascertaining the optimal monitoring network. In the first step, the air-quality patterns in the data base are collapsed into a single composite pattern through a figure-of-merit (FOM) concept. The most-desirable locations are ranked and identified using the resultant FOM fields. In the second step the network configuration is determined on the basis of the concept of spheres of influence (SOI) developed from cutoff values of spatial-correlation coefficients between potential monitoring sites and adjacent locations. The minimum number of ...
Based on wind tunnel experiments, theoretical considerations and measurements the dispersion model CAR (Calculation of Air pollution from Road traffic) has been developed for determining airquality in city streets. CAR International is a simple parameterized model using readily available input data and calculating annual percentile values and average concentrations close to streets (at the kerb side) for non-reactive air pollutants and NO{sub 2}. Originally the model was set up for the Dutch situation (traffic, meteorology) with a system of fixed parameters. In order to extend its application to other countries the program has been made more flexible and user friendly. User defined system data can now be changed interactively, such as emission factors of passenger cars and trucks, fraction of directly emitted NO{sub 2}, city and regional background concentration, and average regional wind speed. The ...
Industrial premises bear more and more important thermal constraints which can commonly reach 150 W/m{sup 2} and more. The reason is the general development of automation and automatic devices and the better thermal insulation of buildings. Production quality requires also more and more strict ambient conditions (temperature, humidity, airquality, air flow etc..). Thus, the air-conditioning market in the industrial sector is more linked to economic factors such as productivity and profit than to thermal comfort of workers. However, the air-conditioning potentialities in the industrial sector remains under-exploited in France. This paper analyzes the reasons of this situation in terms of investments and equipments. (J.S.)
By means of a numerical simulation model (PHOENICS) the air flow and the distribution of the air concentration in an operating room of an hospital have been calculated. Comparisons were made for 11 different conditions (m[sup 3]/h air flow, speed of the air supply in the centre, the middle and outside of the room), of which six cases are discussed in this article, in order to optimize the air flow pattern in the room. The calculations were conducted for the so-called Howorth system. It is shown that the inlet velocity profile with a higher inlet velocity in the center zone of the hood gives the best results. The calculated results were validated by some measurements and experiments with smoke. 7 figs., 2 tabs., 8 refs.
This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor airquality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.
As part of its airquality monitoring activities, Alberta Environment conducts unannounced mobile airquality surveys each year using the Department's Mobile Air Monitoring Laboratory (MAML). This laboratory provides a snapshot of the airquality at the location monitored for a particular time and space. The MAML measures several pollutants in the air including ammonia, carbon monoxide, hydrocarbons, oxides of nitrogen, ozone, particulate matter, reduced sulphur compounds and sulphur dioxide. Alberta Environment conducted a series of ambient airquality monitoring surveys in the Lloydminster Area in 2002, 2003 and 2004. This report presents the results of the five monitored locations over eight seasons of monitoring, which were selected in consultation with stakeholders ...
In response to the 1990 Clean Air Act, the CaliforniaAir Resources Board (CARB) developed a compliance plan known as the Low Emission Vehicle Program. An integral part of that program was a sales mandate to the top seven automobile manufacturers requiring the percentage of Zero Emission Vehicles (ZEVs) sold in California to be 2% in 1998, 5% in 2001 and 10% by 2003. Currently available ZEV technology will probably not meet customer demand for range and moderate cost. A potential option to meet the CARB mandate is to use two Lawrence Livermore National Laboratory (LLNL) technologies, namely, zinc-air refuelable batteries (ZARBs) and electromechanical batteries (EMBs, i. e., flywheels) to develop a ZEV with a 384 kilometer (240 mile) urban range. This vehicle uses a 40 kW, 70 kWh ZARB for energy storage combined with a 102 kW, 0.5 kWh EMB for power peaking. These technologies are ...
This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, airquality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).
Fins serve as heat transfer augmentation features in solar air heaters; however, they increase pressure drop in flow channels. Pin fins are relatively good heat transfer augmentation features with superior aerodynamic performance, and as a result find application in some solar air heaters. The exergy optimization method is employed in sizing the pin fin. Results indicate that high efficiency of the optimized fin improves the heat absorption and dissipation potential of a solar air heater. With optimum fin efficiency and superior absorptive coating quality, useful energy losses can be minimized. Some important observations pertinent in design are made. (author)
The Meteorology and AirQuality (MAQ) group at Los Alamos National Laboratory maintains and operates a large network of environmental air samplers called AIRNET. Some of these samplers are located near Material Disposal Area C at TA-50, a low-level radioactive waste burial site in the semiarid environment of the Pajarito Plateau, near Los Alamos. AIRNET sampling media consist of a filter and silica gel. They are exchanged once every 2 weeks. Presented are 5 months of air sampling results for 5 stations operating in the vicinity of Material Disposal Area C.
In the international study of IEA Annex 27 `Demonstration and evaluation of domestic ventilation systems` a number of simple tools to gain insight into the characteristics of ventilation systems for dwellings are presented. The assessment is made with respect to e.g. indoor airquality, comfort, noise, energy, costs and reliability. In three articles the results of Annex 27 will be discussed. In the first article background information of IEA Annex 27 was given as well as applications in the Netherlands. In this second article attention is paid to the assessment models (`simplified tools`) for indoor airquality, thermal comfort and noise. 6 refs.
The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, airquality, and thermal comfort in a real building. (author)
The cost incurred every year in West Germany due to air pollution is investigated. Damage to buildings, materials, and vegetation are evaluated as well as the cost of additional cleaning work and changes of location with the objective of getting a picture of the economic value of air pollution abatement. The findings are based on data of immission damage in high-exposure areas. Damage is assessed in consideration of the frequency of repair measures in industrial and country atmosphere. Further research will be necessary in view of the many problems concerning methods and availability of basic statistical data. The sequential cost estimated for a few selected cases of damage show that economic losses due to air pollution amount to several thousand million DM. Air pollution abatement measures thus do not only improve our quality of life but also help to save considerable cost to our ...
An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, airquality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air ...
Unlike the conventional automotive, modem railway trains are designed with non-openable windows; and a mechanical ventilation and air-conditioning (MVAC) system is installed in each train compartment for better indoor airquality as well as to provide a thermally comfortable environment. The ventilation rate is no doubt a critical element in the design of a MVAC system, especially in Hong Kong where the daily passenger load is extremely heavy. Earlier studies illustrated that carbon dioxide can be controlled at 1000 ppm by increasing the ventilation rate to 25.2 m{sup 3} h{sup -1}; however, it will also lead to an increase in energy consumption. In this paper, the electrical energy consumption at various ventilation rates was studied, and the cost of maintaining a low carbon dioxide level was estimated These provide solid information for the local railway companies to improve the air ...
Abstract Microbiological quality and biophenol content evolution was studied in minimally processed Thassos cv table olives by hot air dehydration under mild conditions (40C, 24-h, aw-=-0.893) and storage under characteristic packaging conditions (vacuum, 100% N2 and air) at 4 and 20C over a period of 180 days. No salt was used in the production line or packaging. The undesirable microorganisms (Enterobacteriaceae, Staphylococcus aureus, Bacillus, Clostridium) were undetectable until the end of the storage period. Also, modified atmospheres prevented fungal growth at both temperatures apart from the samples stored in air, in which Penicillium and Aspergillus spp. were identified. At 20C, a coexistence of mesophilic bacteria and yeasts occurred. At 4C, yeasts were the predominant microflora...
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to airquality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
Inclusion of environmental externality costs in the selection of utility resources has become a reality in New York, Massachusetts, Nevada and California. Soon several other jurisdictions are likely to join these states in using environmental externality costs in decision-making. The consideration of environmental externalities are bound to profoundly affect utility decision-making in the future. So far attention has focused largely on air emission externalities of SO_2, NO_x and CO_2. However, the recent Clean Air Act Amendments (CAAA) will reduce SO_2 emissions from utilities by about 50 percent. With such a large reduction in SO_2 loading, the question has been raised as to the need to further consider SO_2 externality costs in decision-making. This paper comments on this issue. By using generation and emission data from New York utilities, the paper shows that SO_2 emission externalities exist even after complying with ...
Fairbanks Fairbanks Alaska University of Arizona College of Public Health Tucson Arizona University of California Los Angeles California RAND Corporation Santa Monica California...
The article presents measures for the solution of construction-biological problems and for reducing the pollutant load of buildings. (HW) [Deutsch] Der Artikel berichtet ueber Massnahmen ueber Sanierung von baubiologischen Schwachstellen und Schadstoffbelastungen in Gebaeuden. (HW)
The ``Passivhaus Darmstadt-Kranichstein`` is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m{sup 2} of living area, thereof about 12 kWh are needed for room heating. The determining factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The results of a detailed monitoring program allow decisive statements concerning reduction of energy consumption, relief of environment, indoor airquality, and thermal comfort. (author)
A key comparison has been made between the air-kerma standards of the ARPANSA and the BIPM in the low-energy X-ray range. The results show the standards to be in agreement at the level of the combined standard uncertainty of 7.0 parts in 10"3 for the 10 kV radiation quality and 3.7 parts in 10"3 for all other beam qualities. The results are analysed and presented in terms of degrees of equivalence, suitable for entry in the BIPM key comparison database. (authors)
Reinforcement of the legislation concerning the emission of atmospheric pollutants, aerosols, refrigerants, solvents etc and the reduction of the greenhouse effect, has led to the development of performing instruments for the survey and control of ambient airquality and for the limitation of exhaust gases, combustion products, volatile organic compounds (VOC), particulates and noxious compounds in the atmosphere. This study is divided in 4 main parts. The first part describes the context of the airquality control: the problems linked with the environment and health, the pollutants characteristics, the pollution levels and the detection sensitivity of instruments according to the different type of pollutants (petroleum products, VOCs, ozone compounds, particulates, smells..), the protocols of air pollution measurements and their application (chimney smokes, industrial volatile ...
The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor airquality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.
This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; airquality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)
The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).
The Conference on Building Design and Architecture organized by Swedish Council for Building Research Contents included articles on building physics, thermal-climate technology, indoor-air-quality technology, construction materials, quality assurance, and building policy and regulation.
... Carbon capture and storage Waste Prevention and Recycling EU clean air strategy Environmental liability: Applying the 'polluter pays' principle What goes around ...comes around: Recycling and climate change Behind closed doors: Airquality in buildings Keeping cool with refrigerants: The F-gas review Regions fighting climate ...
Conventional, recirculating, and intermittent type peanut dryers were compared in a three-year study. Comparisons indicate that partial recirculation of peanut drying air may reduce energy consumption per unit of water removed by approximately 25% while also reducing required drying time and maintaining high quality.
The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel ...
New York City data indicate that seasonal and annual variations in dispersion-normalized air pollutant concentrations appear to accurately reflect changes in source emission patterns. The normalized concentrations make it possible to observe the impact of regulatory changes on ambient airquality without these impacts being obscured by meteorological fluctuations. It is found that numerical modeling techniques and regression analysis can be powerful tools for extracting information from large sets of airquality data. The use of differential, as opposed to absolute, pollutant concentration values will reduce artifact correlations caused by seasonal, weekly, or daily meteorological fluctuations and will permit more accurate estimation of the regression coefficients. This technique was successfully applied to a set of daily pollution measurements whose absolute concentrations were ...
New York City data indicate that seasonal and annual variations in dispersion-normalized air pollutant concentrations appear to accurately reflect changes in source emission patterns. The normalized concentrations make it possible to observe the impact of regulatory changes on ambient airquality without these impacts being obscured by meteorological fluctuations. It is found that numerical modeling techniques and regression analysis can be powerful tools for extracting information from large sets of airquality data. The use of differential, as opposed to absolute, pollutant concentration values will reduce artifact correlations caused by seasonal, weekly, or daily meteorological fluctuations and will permit more accurate estimation of the regression coefficients. This technique was successfully applied to a set of daily pollution measurements whose absolute concentrations were ...
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit ...
In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm ...
In this paper we present results of our investigation into the relationship between urban microclimate and the local density of tree cover as measured in Sacramento, California. These results were obtained through analysis of data collected in a two-month long monitoring program with automatic weather stations installed at 15 residential locations throughout the city. Measured wind speeds showed a highly negative correlation with respect to tree cover. Daily peak air temperatures showed significant variation often differing from site to site by 2 to 4{degrees}C ({approx}3.5 to 7{degrees}F). A complex interaction between several competing factors is discussed leading to the conclusion that additional tree cover may actually increase urban air temperatures on synoptically cool days. It is suggested that this does not have a significant adverse affect in terms of overall summer urban cooling load. This is supported by an ...
The major purpose of the work described in this report was to use diffusion modeling techniques to calculate the impact on ambient airquality of SO2 emissions from the ASARCO copper smelter in Tacoma, Washington for the existing smelter configuration (51-percent constant emissions control) and for 20 alternative smelter configurations with varying degrees of constant emissions control. The accuracy of the modeling techniques was established by the close correspondence obtained between calculated and observed short-term ground-level SO2 concentrations for 20 selected historical cases, when high hourly SO2 concentrations were measured in the area surrounding the smelter, as well as by the close agreement between calculated and observed annual average concentrations for 1972. The results of the model calculations show that the maximum allowable constant SO2 emission rate consistent with maintaining the Washington Department of Ecology (DOE) and ...
The indoor climate of school buildings have been much debated recently. Many problems connected with airquality and thermal comfort are caused by bad maintenance, fitted carpets and no sunshades. Mechanical ventilation in schools has gained a bad reputation and many municipalities are seeking other solutions when building new schools. Natural ventilation according to the ''Swedish model'' does not use air filters or heat recovery from the outgoing air and achieve low energy consumption by reducing the airflow substantially in cold weather. Most of the naturally ventilated schools have supply air culverts of concrete below ground outside the building and in the basement. This is also true of schools using hybrid ventilation, where natural and mechanical ventilation is combined. The naturally ventilated schools often use manual control of the ...
This study examined the atmospheric pollution created by some waste treatment and disposal facilities in the State of Kuwait. Air monitoring was conducted in a municipal wastewater treatment plant, an industrial wastewater treatment plant established in a petroleum refinery, and at a landfill site used for disposal of solid wastes. Such plants were selected as models for waste treatment and disposal facilities in the Arabian Gulf region and elsewhere. Air measurements were made over a period of 6 months and included levels of gaseous emissions as well as concentrations of volatile organic compounds (VOCs). Samples of gas and bioaerosols were collected from ambient air surrounding the treatment facilities. The results obtained from this study have indicated the presence of VOCs and other gaseous pollutants such as methane, ammonia, and hydrogen sulphide in air surrounding the waste treatment and disposal ...
To meet BPA`s contractual obligation to supply electrical power to its customers, BPA proposes to acquire power generated by Klickitat Cogeneration Project. BPA has prepared an environmental assessment evaluating the proposed project. Based on the EA analysis, BPA`s proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 for the following reasons: (1)it will not have a significant impact land use, upland vegetation, wetlands, water quality, geology, soils, public health and safety, visual quality, historical and cultural resources, recreation and socioeconomics, and (2) impacts to fisheries, wildlife resources, airquality, and noise will be temporary, minor, or sufficiently offset by mitigation. Therefore, the preparation of an environmental impact statement is not ...
To reduce the cost of the formed coke briquettes which can be used as a substitute fuel to the metallurgical coke for the blast furnace from the coke breeze alternative binders and their blends were used. The high temperature behavior was investigated. The binders tested were: the nitrogen blown, air blown coal tar pitch and the blend of air blown coal tar pitch with the phenolic resins blends. The phenolic resin blends were prepared by mixing equal amount of resole and novalac. From the results, nitrogen blowing resulted in the weakest briquettes. The air blowing procedure should be preferred in place of nitrogen blowing for this purpose. When the air blown coal tar pitch was used alone as a binder, the briquettes must be cured at 200^oC for 2h, then carbonized at a temperature above 670^...
This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor airquality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)
In 1991, the airquality monitoring program in Alberta consisted of continuous, intermittent, static, portable, mobile, and acid precipitation monitoring networks. The airquality monitoring networks are described and results from the continuous, intermittent, static, and acid precipitation networks are summarized. Regulations and guidelines for individual pollutants are discussed in detail. Pollutants monitored continuously (1-h average basis) include ammonia, CO, coefficient of haze, H{sub 2}S, nitrogen oxides, ozone, SO{sub 2}, and total hydrocarbons. Good airquality was observed most of the time at all continuous monitoring stations in 1991. The frequency of good airquality ratings ranged from 81% at the Edmonton northwest station to 98% at the Fort McMurray station. Intermittent monitoring (every 6th day) was ...
The World Bank is analyzing the role of economic policy instruments for the control of air pollution in Poland, in cooperation with Polish and international experts. The first stage, covering Poland as a whole, was recently completed, jointly financed with the U.S. E.P.A. and the Government of the Netherlands. The second stage, now under way, will extend the analysis into a specific regional framework. Stage 2 is financed by the World Bank, the Polish Government, and the U.K. Environment Know-How Fund. Air Pollution in Poland is overwhelmingly caused by energy production and uses, due to the fact that the Polish economy depends heavily on coal and lignite. At present, vehicles contribute less to total emissions than do coal burning and industrial processes, although they account for 25-35% of nitrogen oxides, carbon monoxide, hydrocarbons and lead; and the concentrated in areas of high population density. The paper shows how economic, technical ...
The study described in this report is part of a project sponsored by the Toronto Atmospheric Fund, performed at the Lawrence Berkeley National Laboratory, to assess the potential role of surface property modifications on energy, meteorology, and airquality in the Greater Toronto Area (GTA), Canada. Numerical models were used to establish the possible meteorological and ozone air-quality impacts of increased urban albedo and vegetative fraction, i.e., ''cool-city'' strategies that can mitigate the urban heat island (UHI), significantly reduce urban energy consumption, and improve thermal comfort, particularly during periods of hot weather in summer. Mitigation is even more important during critical heat wave periods with possible increased heat-related hospitalization and mortality. The evidence suggests that on an annual basis cool-city strategies are beneficial, and the implementation ...
This paper presents the results of a study carried out at three sites in Madurai, India in order to assess ambient airquality levels and their impact on public health in urban areas. Indicators of public health were sought through primary and secondary health data and blood lead concentrations of male and female inhabitants and shopkeepers. Lean concentrations in blood samples were examined according to distance from the road, age, smoking status, hours of stay per day in the city, and period of stay in years in Madurai. Ambient airquality level indicators included the level of gaseous and particulate pollution using Central Pollution Control Board standard estimation methods. Observed atmospheric conditions across the three sites are examined according to mean solar insolation, mean temperature, mean relative humidity and mean wind velocity. The study concluded that pollution abatement measures must ...
The aim of this paper is to present and evaluate control strategies for adjustment and preservation of airquality, thermal and visual comfort for buildings' occupants while, simultaneously, energy consumption reduction is achieved. Fuzzy PID, fuzzy PD and adaptive fuzzy PD control methods are applied. The inputs to any controller are: the PMV index affecting thermal comfort, the CO{sub 2} concentration affecting indoor airquality and the illuminance level affecting visual comfort. The adaptive fuzzy PD controller adapts the inputs and outputs scaling factors and is based on a second order reference model. More specifically, the scaling factors are modified according to a sigmoid type function, in such a way that the measured variable to be as closer as possible to the reference model. The adaptive fuzzy PD controller is compared to a non-adaptive fuzzy PD and to an ON-OFF one. The comparison ...
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without significantly changing the temperature of the room envelope. As heat storage takes place ...
There are certain factors to take into account when determining the suitability of a healthy house site. Power lines, agricultural spraying, vehicle exhaust, and industrial pollution are all potential sources of indoor air contamination. It is recommended that a environmental assessment be done to determine whether there are specific sources of contamination. Good drainage is required. The surrounding landscaping should be open and sunlit, and with low maintenance requirements. Decks and fences made from pressure-treated or chemical treated lumber should be avoided. One of the early decisions in the design process is the choice of the structural system. The key with all foundation types is to control moisture, whether from rain, from the ground, or the condensation of moisture from the air with cooling. The construction frame is sealed away from the occupants by the air/vapor barrier, so only in extreme cases is it ...
The influence of location of airborne particle source, ventilation rate, air inlet size, supply air velocity, air outlet location, and heat source on the distributions of airborne particle concentration and draught risk in an operating room is investigated. The investigation is carried out by using a flow program with the k-[epsilon] model of turbulence. Based on a standard case, five cases, each with one changed parameter, are computed, and the detailed field distributions of air velocity, temperature, airborne particle concentration, and draught risk are presented. The parametric study concludes that, for a better airquality and thermal comfort, it is desirable to use a higher inflow rate, a larger inlet area, and a uniform velocity profile of supply air. Outlet location and heat source have little influence on the distributions of the ...
Urea-formaldehyde resin bonded particle board, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present in almost every office, home and public building. If large quantities of these products are used in poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make it possible to predict the performance of UF-bonded pressed wood materials if use conditions and environmental parameters are known. Recent modifications in adhesive and board manufacturing parameters have made it possible to reduce formaldehyde emission ...
This document provides details on a $120.2 million package of initiatives to implement the Ozone Annex, an agreement signed in December 2000 between Canada and the United States to significantly reduce transboundary smog causing pollutants and to improve airquality. Taking action under the Ozone Annex will address health and environmental challenges by reducing emissions of nitrogen oxides and volatile organic compounds which are precursors to ground-level ozone. This document described the actions that will be taken by the Government of Canada to reduce emissions from vehicles and the fuels that power them. It also described the measures that will be taken to improve airquality monitoring networks. The National Pollutant Release Inventory will be used to meet new reporting commitments contained in the Annex. This document also highlights the initial actions that will be taken to reduce pollution from ...
An overview is given of several computer models in use in the Netherlands to determine and analyze the quality of air and the effect of air pollution abatement measures. [Dutch] Voor het vaststellen van de luchtkwaliteit of het bepalen van het effect van emissiereducerende maatregelen op die luchtkwaliteit zijn in ons land meerdere computermodellen beschikbaar. In het kader van het Vooronderzoek Innovatieprogramma Luchtkwaliteit (VIPL) wilde het ministerie van Verkeer en Waterstaat meer inzicht in de betrouwbaarheid en specifieke eigenschappen van deze modellen. Deze studie geeft daarom een overzicht en analyse van de verschillen, overeenkomsten en voor- en nadelen van de meest gangbare Nederlandse computermodellen om de luchtkwaliteit rond snelwegen te bepalen. Dit zijn: Het Voorspellingssysteem Luchtkwaliteit Wegtraces (VLW); CAR-II; Het TNO-verkeersmodel; Het Heaven-model van TNO; Urbis (air); en ...
Papers are presented on the modeling, dispersion, formation, transformation, monitoring and biological effects of atmospheric pollution. Specific topics include a prognostic mesoscale model for pollutant transport and diffusion, commuter exposure modeling, a Gaussian plume model for an urban area, carbon monoxide dispersion in an urbanized area, wind-tunnel modeling of flue gas dispersion, the regional-scale transport of fine aerosol components in eastern North America, and a Markov process for the generation of hourly average wind vectors. Attention is also given to photochemical aerosol formation in multicomponent systems, heterogeneous nitrogen oxide-particulate reactions, the generation and measurement of primary soot aerosols of size between 50 and 400 A, inertial particle size classification techniques, the design of airquality monitoring networks, visibilities in polluted and unpolluted areas, and monitoring air ...
This paper describes an approach to solve airquality problems which frequently occur during iterations of the baseline change process. From a schedule standpoint, it is desirable to perform this evaluation in as short a time as possible while budgetary pressures limit the size of the staff available to do the work. Without a method in place to deal with baseline change proposal requests the environment analysts may not be able to produce the analysis results in the time frame expected. Using a concept called the Rapid Response AirQuality Analysis System (RAAS), the problems of timing and cost become tractable. The system could be adapted to assess other atmospheric pathway impacts, e.g., acoustics or visibility. The airquality analysis system used to perform the EA analysis (EA) for the Salt Repository Project (part of the Civilian Radioactive Waste ...
The Burrard Thermal Generating Station is located at Port Moody, British Columbia, and burns natural gas to supply steam to six turbine units for generating up to 912 MW of electricity. The Burrard plant accounts for ca 8.7% of the provincial generating capability. Burrard is expected to continue to fill a vital role as a supplier of displaceable firm energy to the British Columbia Hydro system. In parallel with a renewed focus on Burrard from a system planning perspective, there have also been concerns about air pollution from the plant in the context of its possible effect on the region's airquality. To address this and other issues surrounding Burrard's future, B.C. Hydro established a project team to conduct a utilization study. The team's work focused on the role of Burrard in providing a reliable and profitable role in electricity generation, the options for dealing with the ...
Ventilation systems must ensure high room airquality with minimum energy consumption in all states of operation. Systems for ventilation on demand are increasing their market share. (orig./MSK) [Deutsch] Oberste Aufgabe von Raumlufttechnischen Anlagen ist die Sicherstellung guter Raumluftqualitaet bei minimalem Energieverbrauch unter allen Betriebsbedingungen. Um dieses Ziel zu erreichen, setzt sich am Markt zunehmend die bedarfsgeregelte Lueftung durch. (orig./MSK)
This document defines the services the Waste Sampling and Characterization Facility (WSCF) shall provide Effluent Monitoring (EM) throughout the calendar year for analysis. The internal memo contained in Appendix A identifies the samples Em plans to submit for analysis in CY-1995. Analysis of effluent (liquid and air discharges) and environmental (air, liquid, animal, and vegetative) samples is required using standard laboratory procedures, in accordance with regulatory and control requirements. This report describes regulatory reporting requirements and WSCF services and data quality objectives.
There is very little quantitative documentation of actual improvements resulting from the installation of new general ventilation systems in industrial settings. Therefore the performance of the common mixing design principle was compared to the displacement design principle by means of an intervention study in a workshop (V = 12,000 m[sup 3]), where thermoplastics were moulded. An experimental signal-response tracer gas technique was used. In terms of supplying fresh air to the zone of occupancy the displacement system was better than the mixing system by a factor of 2. In terms of the exposure level to a simulated contaminant (tracer gas) the displacement system was better by a factor 1.5-18. (author)
This paper describes a semi-empirical calculation of the air-broadened half-widths and the air pressure-induced frequency shifts for the H_2"1"6O isotopologue. This semi-empirical calculation is based on fits of several recent high-quality measurements and theoretical calculations to the first-order terms in the expansion of the complex Robert-Bonamy (CRB) equations, which yields a second- and first-order polynomial function of the differences in the upper- and lower-state vibrational quantum numbers for the half-width and line shift, respectively. The aim of this work was to obtain a complete set of air-broadened half-widths and air pressure-induced frequency shifts for transitions of H_2"1"6O present in the HITRAN database from microwave to the visible in order to supplement the observed and calculated values. For around 700 sets of rotational quantum numbers ...
Energy conservative building design has triggered greater interests in developing flexible and sophisticated air conditioning systems capable of achieving enhanced energy-savings potential without sacrificing the desired thermal comfort and indoor airquality (IAQ). This research work greatly aimed at achieving enhanced energy conservation, good thermal comfort and better IAQ for space conditioning with the application of combined variable refrigerant volume (VRV) and variable air volume (VAV) air conditioning (A/C) systems. Experimental investigation on the proposed combined air conditioning system with the application of intelligent fuzzy logic controller was performed for summer and winter climatic conditions to substantiate the energy-savings capability. The proposed system experimentally analyzed under fixed ventilation, demand controlled ventilation (DCV) ...
A major outbreak of penicillinase-producing Neisseria gonorrhoeae occurred in California beginning in late 1986. After a state public health emergency was declared in April 1987, a statewide, cooperative...Full Text Available
A duplex TaqMan real-time RT-PCR assay was developed for the detection of California (CAL) serogroup viruses and Cache Valley virus (CVV), for use in human surveillance. The targets selected...Full Text Available
This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...
The propagation of acoustic pressure perturbations in an adiabatic low-qualityair/water flow were investigated both theoretically and experimentally. A linearized dispersion model is correlated with data to extract information on the behavior of interfacial momentum transfer controlled by the virtual volume coefficient. The dispersion model is examined in limiting cases of low and high frequency and related to current models for critical flow velocity. Fourier decomposition techniques are employed to predict the dispersion of measured pressure pulses and to relate data for standing waves and propagating pulses. The dispersion model is based on a two-fluid model and is the most complete model available in the literature at this time. The dispersion data presented herein is also the best available to date for low frequency (i.e., frequencies less than bubble resonance) sound propagation in bubbly air/water mixtures.
In parking areas of large extent, the removal of engine exhaust gases, especially of their CO gas components with ventilation plant is mainly done by transverse ventilation over short paths. By their presence, the ventilation ducts required for this purpose often reduce the value of the parking space by restrictions with a consequent reduction of their acceptance by the users. Longitudinal ventilation without ducts can be a remedy in such cases. Depending on the required room airquality in the zones of highest loading, the volume flows with longitudinal removal are no greater than with conventional transverse ventilation. This article is concerned with the different methods of operation of the two systems. (orig./BWI)
Displacement Ventilation (DV) offers a great opportunity to improve indoor airquality while reducing the energy consumption compared to mixing ventilation. A frequent problem with displacement ventilation is however the draft discomfort caused by the cold air movement at foot level and excessive temperature difference between head and ankle. Despite numerous past studies, there is still a lack of detailed data regarding the velocity and temperature distribution inside DV jets. In this experimental study, measurements of the air velocity and temperature are performed in the DV jet produced by a flat wall-mounted DV diffuser, using a fine mesh focused on the 0.00-0.20 m height range. Two supply conditions are studied. Three planes of measurements are covered: the vertical longitudinal plane...
Environmental data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, and game birds), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1979 were indistinguishable from background levels. The data are summarized in the following highlights. Airquality measurements of NO/sub 2/ in the vicinity of the Hanford Site and releases of SO/sub 2/ onsite were well within the applicable federal and state standards. Particulate air concentrations exceed the standards primarily because of agricultural activities in the area. Discharges of waste water from Hanford facilities in the Columbia River under the National Pollution Discharge Elimination System (NPDES) permit were all within the parameter limits on the ...
A series of upper tropospheric radon concentration measurements made over the eastern Pacific and west coast of the United States during the summers of 1983 and 1984 has revealed the occurrence of unexpectedly high (>16 pCi/SCM) radon concentrations for 9 of the 61 measurements (and 6 of the 13 flights). A frequency distribution plot of the set of 61 observations shows a distinct bimodal distribution, with approximately 2/5 of the observations falling close to 1 pCi/SCM, and 3/5 falling in a high concentration mode centered at about 11 pCi/SCM. Trajectory and synoptic analyses for two of the flights on which such high radon concentrations were observed indicate that this radon-rich air originated in the Asian boundary layer, ascended in cumulus updrafts, and was carried eastward in the fast moving air on the anti-cyclonic side of the upper tropospheric jet. Transit times were of the order of 3 days; however, in one instance, transport from ...
...ER14AU08.000 (6) Unit 2: North Baldwin Meadow, San Bernardino County, California...and ARUR 12. Gold Mountain and North Baldwin Lake, San Bernardino County, California...ER26DE07.007(13) Unit ARUR 15. South Baldwin Ridge/Erwin Lake, San Bernardino...
For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor airquality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor airquality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather ...
In car parks of considerable length, the removal of exhaust emissions, is carried out by air-conditioning systems mainly through transverse ventilation over short routes. The required air-conditioning ducts frequently produce a reduction in the available parking space simply due to their presence, resulting in restrictive effects on the level of acceptance by the users. In such cases, remedial action can be taken by creating ductless longitudinal ventilation. Depending on the required room airquality in the zones with the highest level of pollution, the volumetric flows for longitudinal disposal are no greater than those for conventional transverse ventilation. In conjunction with architecturally clear and positive lighting designs, clearly laid out car parks with a friendly atmosphere can be created which the user will be pleased to accept. (orig./BWI)
The growing global public concern over deteriorating airquality and greenhouse gases emissions released from various combustion processes, and particularly power plants and transportation system, led governments and local authorities, especially in industrialised countries into taking these issues seriously and establishing standards to reduce air pollution down to acceptable levels, (clean air act, earth summit,...). The transportation sector has another unwanted product, noise pollution caused by different segments of this sector including the noise produced by the engine, tires noise and exhaust noise, in addition to the noise product by private standby generals operating during electricity cut-off periods. To be able to estimate the environmental impacts of the national power plants and the transportation sector, it is necessary to collect enough data (samples of lead emissions, SO_2 concentration, ...
Modernisation of older office buildings commonly includes installation of air conditioning systems as good airquality and thermal comfort will improve the staff`s efficiency at work. However, what about tenants who want their own, individually controlled single-storey air conditioning plang? And what about retrofitting further storeys with single-storey air conditioning? An exemplary solution to this problem was found in Hamburg. (orig.) [Deutsch] Bei der Sanierung aelterer Buero- und Geschaeftshaeuser werden die Raeume immer haeufiger mit Klimaanlagen ausgestattet. Ein Grund fuer den Trend zur Klimatisierung: Gute Luftqualitaet und angenehme Temperaturen erhoehen die Leistungsfaehigkeit des Menschen. Was aber, wenn ein Mieter fuer seine Bueroetage eine eigene, individuell steuerbare Klimaanlage wuenscht? Und was passiert, wenn andere Bueroetagen mit weiteren Klimaanlagen ...
During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)
This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)
... Reduce partner costs, save time, and overcome delays in data transmission. Data Exchanges States are currently submitting data to each other and to the EPA in the exchanges listed below. Data Exchanges are typically referred to by their acronyms, which are listed below. To find out more about EPA data exchanges, please follow the links to EPA Web sites. AQS - AirQuality Sub-system (...
Proper estimation of shipping emissions is essential for an impact assessment of shipping on airquality and health in port cities and coastal regions. In the Netherlands shipping is an important source of particulate matter. This report provides an internationally accessible and transparent summary and description of the methodologies used in the Netherlands Pollutant Release and Transfer Register (PRTR) to estimate PM emissions from shipping, including recently implemented updates.
In this third, and concluding, article of the series the emission limits set by the US Clean Air Act and its amendements are set out. A number of flue gas desulfurization processes that have been developed for the utility and industrial markets are evaluated. Annual operating costs are indicated.
This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor airquality, commissioning, economics, operations and maintenance, and monitoring.
This document deals with energy management in buildings. It presents the conditions for a good implementation of energy management. These conditions include the total involvement of the management and the training of the staff. The structure of this implementation is presented together with the tools for an efficient energy management. Eventually, information on airquality and comfort in buildings is provided, as well as the management of complaints linked to them. (TEC). 1 tab.
An overview is given of techniques to analyze all kinds of complaints from occupants of office buildings about their working environment: headaches, lethargy, eye irritation, respiratory problems, and complaints about the temperature and draught. Special attention is paid to the sensory evaluation of airquality. 4 figs., 7 refs.
This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.
This report reviews Nova Scotia's initiatives in support of the Canada-Nova Scotia Acid Rain Reduction Agreement. In addition to discussing sodium dioxide emmisions and potential impacts, the report comments on new developments and initiatives to address other emerging airquality issues.
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) ...
Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor airquality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO{sub 2} concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy ...
Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner ...
This analysis of the June 8, 1976 California Nuclear Initiative was prepared by the Pacific Gas and Electric Co. The defeat of Proposition 15 in the California election was successful for several reasons. A record 70 percent of the voters in California went to the polls and 97 percent of those voted on the nuclear issue with the results showing defeat by two-to-one. Apparently, the voters perceived the Nuclear Initiative as being too drastic. The campaign for defeat of the initiative stressed the consequences of closing down existing plants and closing off the nuclear option in California, namely: higher costs, job losses, and less-desirable alternatives. The campaign waged for the Initiative seems to have suffered from weak management and lack of consistent messages.
The Granger instantaneous-causality test is applied to explore the potential causal relationships between wholesale electricity and natural-gas prices in California. The test shows these relationships to be bi-directional, and reveals California's electricity and natural-gas markets to be as inextricably intertwined as casual observation and theoretical considerations would suggest they ought to be. This meshing of markets exacerbated the effects of California's natural-gas crisis on the contemporaneous electricity crisis, while concurrently the electricity crisis may have contributed to the dysfunction in the national-gas market and helped to precipitate the natural-gas crisis. The finding supports an integrated approach, as opposed to a piecemeal approach, for formulating energy policy recommendations, not just in California but in the world at large. (author)
The Granger instantaneous-causality test is applied to explore the potential causal relationships between wholesale electricity and natural-gas prices in California. The test shows these relationships to be bi-directional, and reveals California's electricity and natural-gas markets to be as inextricably intertwined as casual observation and theoretical considerations would suggest they ought to be. This meshing of markets exacerbated the effects of California's natural-gas crisis on the contemporaneous electricity crisis, while concurrently the electricity crisis may have contributed to the dysfunction in the national-gas market and helped to precipitate the natural-gas crisis. The finding supports an integrated approach, as opposed to a piecemeal approach, for formulating energy policy recommendations, not just in California but in the world at large.
California's pacific coast stretches roughly over 11.5 latitudinal degrees, extending from about 32.5{sup o}N to 44{sup o}N. There is nearly 900nm of California coastline offering superior opportunity for wave energy use. The longitudinal position of the coast shifts eastward at two distinct locations: Punta Gorda just south of Cape Mendecino in the north and Point Conception in the south. The change in longitudinal orientation in southern California also coincides with significant change in California's bathymetry. The tilts in the longitudinal coastal lines at the two points also define California wave zones into three areas: the short coastal line north of Punta Gorda, the long north and middle line between the two points, and the short line of the heavily populated southern coast. The northern and central zones are characterized by high waves of relatively low ...
In January 1994, a 6.7 magnitude earthquake in southern California ruptured a pipeline releasing approximately 4,200 barrels of blended San Joaquin Valley crude oil. A smaller volume entered the Santa Clara River and flowed 25 km downstream to an emergency containment dam. Ruptured water mains and chlorinated discharges from a damaged sewage treatment plant also affected water quality in the river. Quantitative injury assessment studies were initiated within days of the spill and included water/sediment chemistry, benthic macroinvertebrate community analyses and aquatic toxicity tests. Water quality values for TPH, BTEX, and chlorine ranged from nondetectable to 78 mg/l (TPH), nondetectable to 5.4 microg/l (total BTEX constituents) and nondetectable to 600 microg/l (residual chlorine) within 72 hours of the spill. Ammonia concentrations ranged from nondetectable to 12.1 mg/l within 10 days of the spill. Hydrocarbon ...
The proposed action is to recycle slightly activated copper that is currently stored in a warehouse leased by Lawrence Berkeley Laboratory (LBL) to a scrap metal dealer. Subsequent reutilization of the copper would be unrestricted. This document addresses the potential environmental effects of recycling and reutilizing the activated copper. In addition, the potential environmental effects of possible future uses by the dealer are addressed. Direct environmental effects from the proposed action are assessed, such as air emissions from reprocessing the activated copper, as well as indirect beneficial effects, such as averting air emissions that would result from mining and smelting an equivalent quantity of copper ore. Evaluation of the human health impacts of the proposed action focuses on the pertinent issues of radiological doses and protection of workers and the public. Five alternatives to the proposed action are considered, and their ...
This report focuses on airquality at the Nevada Test Site (NTS) for 1994. A general description of the effluent sources are presented. Each potential source of NTS emissions was characterized by one of the following: (1) by monitoring methods and procedures previously developed at NTS; (2) by a yearly radionuclide inventory of the source, assuming that volatile radionuclides are released to the environment; (3) by the measurement of tritiated water concentration in liquid effluents discharged to containment ponds and assuming all the effluent evaporates over the course of the year to become an air emission; or (4) by using a combination of environmental measurements and CAP88-PC to calculate emissions. Appendices A through J describe the methods used to determine the emissions from the sources. These National Emission Standards for Hazardous Air Pollutants (NESHAP) emissions are very conservative, are ...
In the first part of the nineties many office buildings were equipped with indoor climate installations which do not meet present standards. Several options are available to improve such installations for ventilation capacity, cooling capacity, thermal comfort and airquality. One of the options concern the installation of an air conditioner in combination with heat recovery. In this article attention is paid to the renovation of the air conditioning system in the Printer house, an office building in Zwolle, Netherlands. [Dutch] Begin jaren negentig zijn veel kantoorpanden gebouwd waarvan de klimaatinstallatie tegenwoordig niet meer voldoet. De ventilatiecapaciteit is ontoereikend en koeling is mondjesmaat aanwezig, of slechts als topkoeling. Het comfort en de luchtkwaliteit zijn dan ook onder de maat. Er zijn verschillende mogelijkheden om dit te verbeteren. Plaatsing van een nieuwe ...
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor airquality and thermal comfort. To analyse the level of indoor airquality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The ...
This paper presents an integrated exposure monitoring system, based on an expansion of existing airquality monitoring systems using dispersion modelling. The system allows: (1) identifying geographical areas whose inhabitants are most exposed to ambient pollution; (2) identifying how many people in an area are exposed to concentrations of pollution exceeding airquality guidelines: (3) describing the exposure of population subgroups (e.g. children): (4) planning pollution abatement measures and quantifying their effects; (5) establishing risk assessment and management programs, and (6) investigating the short- and long-term effects of both pollutants and pollution sources on public health. The effect of pollution is rarely very large and in order to discover it, exposure estimation must provide data that reflects both spatial and temporal variations. Estimates of pollution exposure are obtained using ...
It is expected that the progressive increase of tropospheric trace gases such as CO{sub 2} and O{sub 3} will have a significant impact on agricultural production. The single and combined effects of CO{sub 2} enrichment and tropospheric O{sub 3} on grain quality characteristics in soft red winter wheat (Triticum aestivum L.) were examined in field studies using 3 m in diam. open-top chambers. Wheat cultivars {open_quotes}Massey{close_quotes} (1991) and {open_quotes}Saluda{close_quotes} (1992) were exposed to two CO{sub 2} concentrations (350 vs. 500 {mu}mol CO{sub 2} mol{sup {minus}1}; 12 h d{sup {minus}1}) in combination with two O{sub 3} regimes (charcoal-filtered air vs. ambient air + 40 {plus_minus} 20 nmol O{sub 3} mol{sup {minus}1}, 7 h d{sup {minus}1}; Monday to Friday) from late March until maturity in June. Grain quality characteristics investigated included: test weight, milling and baking ...
Solid fuels such as coal, wood, and crop straw supply some fraction of household cooking and heating fuel for more than one billion people in China. As these fuels do not generally combust cleanly in household stoves, their use levies large health and environmental burdens, particularly in rural regions. Production of clean-burning fuels from agricultural residue offers one prospect for mitigating health and social burdens imposed by household use of solid fuels. This dissertation explores the question: how might production of clean-burning household fuels from agricultural residues affect human health and social conditions in rural China? I approach this question from three perspectives. First, a technically plausible but currently unproven village-scale energy technology is explored in a scenario bounded by natural resources and substantiated by engineering specifications, estimates of indoor exposures to air pollution, and epidemiological analyses. This analysis ...
The objective of the study was the kinetic modeling of the effect of storage temperature on the quality and shelf life of chilled fish, modified atmosphere-packed (MAP), and osmotically pretreated with the addition of nisin as antimicrobial agent. Fresh gilthead seabream (Sparus aurata) fillets were osmotically treated with 50% high dextrose equivalent maltodextrin (DE 47) plus 5% NaCl. Water loss, solid gain, salt content, and water activity were monitored throughout treatment and treatment conditions were selected for the shelf life study. Untreated and osmotically pretreated slices with and without nisin (2 x 10(4) IU/100 g osmotic solution), packed in air or modified atmosphere (50% CO(2)-50% air), and stored at controlled isothermal conditions (0, 5, 10, and 15 degrees C) were studied. Quality assessment and modeling were based on growth of several microbial indices, total volatile nitrogen, ...
In Oslo, traffic has been one of the dominating sources of air pollution in the last decade. In one part of the city where most traffic collects, two tunnels were built. A series of before and after studies was carried out in connection with the tunnels in use. Dispersion models were used as a basis for estimating exposure to nitrogen dioxide and particulate matter in two fractions. Exposure estimates were based on the results of the dispersion model providing estimates of outdoor pollutant concentrations on an hourly basis. The estimates represent concentrations in receptor points and in a square kilometre grid. The estimates were used to assess development of air pollution load in the areas, compliance with airquality guidelines, and to provide a basis for quantifying exposure-effect relationships in epidemiological studies. After both tunnels were taken in use, the pollution levels in the study ...
This paper summarizes the current scientific evidence that improved indoor environmental quality can improve work performance and health. The review indicates that work and school work performance is affected by indoor temperature and ventilation rate. Pollutant source removal can sometimes improve work performance. Based on formal statistical analyses of existing research results, quantitative relationships are provided for the linkages of work performance with indoor temperature and outdoor air ventilation rate. The review also indicates that improved health and related financial savings are obtainable from reduced indoor tobacco smoking, prevention and remediation of building dampness, and increased ventilation. Example cost-benefit analyses indicate that many measures to improve indoor temperature control and increase ventilation rates will be highly cost effective, with benefit-cost ratios as high as 80 and annual economic benefits as high ...
The oil sands industry in Canada was said to be committed to environmentally sustainable economic development, i.e. a development that recognizes the mutual dependence of a healthy environment and a healthy economy. To indicate progress toward this goal, the report pointed out the investment of millions of dollars in environmental research and tens of millions of dollars in plant equipment already made. These infrastructure investments have paid dividends in terms of energy conservation, reduction of greenhouse gas emissions, land reclamation, airquality monitoring, water conservation, and water quality and biodiversity protection. A number of recommendations governing provincial jurisdictions over regulations were made. Particular concern was expressed over fairness, and overlapping of regulations by different levels of government.
This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, airquality and noise protection. (author)
TOXCHEM is a microcomputer based modelling system for predicting the fate of toxic contaminants in wastewater treatment plants. The package evaluates concentrations of toxics in final effluent and waste sludge, and mass air emissions from municipal or industrial activated sludge wastewater treatment plants. Maximum allowable influent concentrations of toxics required to meet effluent discharge or air emission limits can also be estimated. The package contains a read-only database with treatability parameters for over 100 contaminants, including organic compounds and metals. If effluent or sludge quality limits have been specified, treatment plant owners and operators can use the package to estimate the permissable discharge limits for dischargers to their collection system. A hypothetical example is provided of application of the software to a planning problem involving the start up of a new operation that would discharge ...
Almost in all the major cities in Asian countries, residential buildings are characterized with high-rise and high density. Under this circumstance, achieving comfortable and healthy indoor environment with minimized energy consumption becomes a very challenging engineering and societal issue. While the wide use of air-conditioning helped to improve thermal comfort, health problems associated with poor indoor airqualities have appeared more frequently. The increased energy consumption is also a great concern in view of its impact on the energy economics of the region. Drawn from some of the onsite measurements and survey, and also the author's personal observation, some of the key issues are discussed in this paper. (author)
In the frame of the comprehensive assessment of Swiss energy systems, airquality simulations were performed by using a 3-dimensional photo-chemical dispersion model. The objective is to investigate the impacts of pollutants in Switzerland for future options of Swiss energy systems. Four scenarios were investigated: Base Case: simulations with the projected emissions for the year 2030, Scenario 1) all nuclear power plants were replaced by oil-driven combined cycle plants (CCP), Scenarios 2 to 4) traffic emissions were reduced in whole Switzerland as well as in the cities and on the highways separately. Changes in the pollutant concentrations and depositions, and the possible short-term impacts are discussed on the basis of exceedences of critical levels for plants and limits given to protect the public health. (author) 2 figs., 7 refs.
Good indoor airquality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)
Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware AirQuality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...
In evaluating commercialization prospects for natural gas fuelled vehicles, this paper compares the performance and emission quality of these innovative vehicles with those using conventional fuels - gasoline and diesel fuels. Assessments are made of the state-of-the-art of current technology relative to fuel storage, air/fuel mixture preparation, in cylinder combustion processes and pollution control. The analysis evidences that while natural gas is an excellent fuel for spark ignition engines, in transport applications its use is hampered by large storage volume requirements and weight. Moreover, the air/fuel mixture preparation, combustion process and exhaust-gas cleaning require a greater research and development effort to make this alternative fuel economically and environmentally competitive with conventional fuels.
Biomass combustion is an important part in a sustainable energy system, but as well a source of submicron (particles < 1 #mu#m) particles in the air. Consequently, to obtain a good airquality together with increased biomass combustion there is a need for a better understanding of particle formation. This work is a part of a larger project about formation and emissions of particles from biofuel combustion. The report includes the work performed in the project during the year 2004. The aim of the project is to describe the release of inorganic components, which cause particle emissions, during combustion of single fuel particles of biofuel, e.g. wood pellets. The work is carried out by emission measurements, systematic combustion experiments and modelling work. The results are expected to contribute to the understanding of which parameters that influence the formation of fine particles and thus gain a better insight into ...
The aim of this work is the evaluation of the quality of a chemistry-transport model, not by a classical comparison with observations, but by the estimation of its uncertainties due to the input data, to the model formulation and to the numerical approximations. The study of these 3 sources of uncertainty is carried out with Monte Carlo simulations, with multi-model simulations and with comparisons between numerical schemes, respectively. A high uncertainty is shown for ozone concentrations. To overcome the uncertainty-related limitations, a strategy consists in using the overall forecasting. By combining several models (up to 48) on the basis of past observations, forecasts can be significantly improved. This work has been also the occasion of developing an innovative modeling system, named Polyphemus. (J.S.)
Meteorological and air-quality data, as well as surface tracer concentration values, were collected during 1990 to assess the impact of Navajo Generating Station (NGS) emissions on Grand Canyon National Park (GCNP) airquality. These data have been used in the present investigation to determine between direct and indirect transport routes taken by the NGS plume to produce measured high-tracer concentration events at GCNP. Results show that complex-terrain features affect local wind-flow patterns during winter in the Grand Canyon area. Local channelling, decoupled canyon winds, and slope and valley flows dominate in the region when synoptic systems are weak. Direct NGS plume transport to GCNP occurs with northeasterly plume-height winds, while indirect transport to the park is caused by wind direction shifts associated with passing synoptic systems. Calculated polluted airmass positions along the modeled streak lines match ...
This report describes the result of work completed during February, 1982 to October 1983. The aim of the work was to develop a low NO(x) emission range top burner. Discussed is the development of a flame insert modification to an existing burner which reduces NO(x) emission by 45 percent and NO2 emission by 25 percent. This relatively simple burner add-on device appears to be an economically viable low NO(x) burner. It was developed in cooperation with a major range manufacturer. The levels of NO(x) (NO2) reduction achieved should significantly reduce the impact of a gas range to indoor quality. The report also discusses the results of a literature search that preceeded the burner development. The search helped to direct the burner development by reviewing the state-of-the-art of low NO(x) burner design and covered factors which affect the indoor impact of range emissions such as air infiltration and ventilation trends, air ...
Mangroves are disappearing rapidly worldwide despite their well documented biodiversity and the ecosystem services they provide. Failure to link ecological processes and their societal benefits has...Full Text Available
... of China Lake Naval Weapons Center, California. ... Figure 4: The Space-Based Laser cleaning ... of Aeronautics and Astronautics (AIAA) Space 2001 ...
... California where he is currently working on an AS in. Data Communication & Network Management as well as Microsoft. MCSE and Cisco CCNA certifications.
Chewing up the Forest: Bark-Eating Beetles Provide Timber for Forest Fires. Droughts in California allow bark beetles to lay eggs into sapless trees, ...
This data layer consists of polygons representing harvest area boundaries from Timber Harvest Plans approved by the California Department of Forestry ... ...
Two additional earthquakes, magnitudes 6.6 and 6.7 occurred the next morning. The first earthquake was located six miles north of Petrolia, California, ...
who was appointed in July to lead the Defense Advanced Research Projects Agency, or DARPA, made visits last week to UC Berkeley, Stanford, UCLA and the California Institute of...
A Composite Architecture for Network Security at JPL. Robert B. Mead, Tom G. Dearmond, and Joseph S. Sherif. JPL, California Institute of Technology ...
Gaseous Nitrogen Dewar apparatus developed by Dr. Alex McPherson of the University of California, Irvine for use aboard Mir and the International Space ...
Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs. Results from this study show that allowable CO{sub 2} levels are overpassed several times in a school day. The presence of a mechanical ventilation system leads to lower peaks but the fresh airflow is too small to prevent an indoor confining, that is also revealed by the aerobiological analysis. (author)
A modelling approach is presented that appears to have the potential to provide reliable assessments of pollution concentration in coastal zones and complex terrain, where the assumptions behind current operational airquality models often are inadequate. With the use of a numerical mesoscale model (NMM), physically consistent flow fields can be predicted, thereby providing higher spatial and temporal resolution in the meteorological fields than would be available from a limited number of observation points. These predictions are used to calculate mean trajectories of pollutant parcels, as well as to provide quantitative estimates of pollution concentration using two techniques.
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior airquality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
Several aspects of low temperature systems (LTS) are discussed in five articles. In the first article the role of municipalities in the Netherlands in the implementation of LTS is outlined. In the second article a brief overview is given of a brochure in which 9 projects with LTS are described. In article three the results of a literature study on qualitative aspects (thermal comfort, airquality, energy consumption, safety and cost) of LTS are presented. In the fourth article it is outlined why one should apply LTS, and the fifth article is a reflection of the discussion that took place at the TVVL symposium on sustainable concepts and sustainable installation
The overall purpose of this research was to evaluate the independent and interactive effects of elevated levels of CO{sub 2} and O{sub 3} on tree leaf litter quality and decomposition. This research was conducted at the Aspen FACE (Free Air CO{sub 2} Enrichment) facility near Rhinelander, Wisconsin. This research comprised one facet of a larger project assessing how CO{sub 2} and O{sub 3} pollutants will alter carbon sequestration and nutrient cycling in north temperate forest ecosystems.
Most K-12 schools could save 25% of their energy costs by being smart about energy. Nationwide, the savings potential is $6 billion. While improving energy use in buildings and busses, schools are likely to create better places for teaching and learning, with better lighting, temperature control, acoustics, and airquality. This brochure, targeted to school facilities managers and business officials, describes how schools can become more energy efficient.
Vol. 4 of the DKV Conference Proceedings 2000 contains 19 papers on airquality, thermal comfort, space HVAC engineering and alternative cooling concepts. [German] Der Band 4 des DKV-Tagungsberichts 2000 enthaelt 19 Beitraege. Sie befassen sich mit speziellen Themen der Heiztechnik; Luftqualitaet und Behaglichkeit; Raumlufttechnik und Alternativen Kuehlkonzepten.
Vol. 4 comprises 23 papers on the following subjects: General aspects (effects in the human/environment systeme); Trends in space HVAC engineering; Heating systems engineering; Airquality and thermal comfort. [German] Der Tagungsband 4 enthaelt 23 Aufsaetze. Sie sind in die folgenden vier Themen-Bloecke aufgeteilt: Allgemeines (Wirkungen in der wahrgenommenen Wirkungssystem: Mensch-Umwelt); Entwicklungen in der Raumlufttechnik; Heizungstechnik; Luftqualitaet und Behaglichkeit. (AKF)
Case studies are presented for treatment of refinery wastes in a pilot-scale thin-film evaporator, the removal of volatiles from industrial wastewater for two steam strippers, and the removal of semivolatiles from water by steam stripping followed by liquid-phase carbon adsorption. The report provides data on removal efficiency, air emissions, process residuals, treatment costs, and process limitations. Details on sampling and analytical procedures, quality assurance, and process data are contained in the Appendixes (Volume II).
Case studies are presented for treatment of refinery wastes in a pilot-scale thin-film evaporator, the removal of volatiles from industrial wastewater for two steam strippers, and the removal of semivolatiles from water by steam stripping followed by liquid-phase carbon adsorption. The report provides data on removal efficiency, air emissions, process residuals, treatment costs, and process limitations. Details on sampling and analytical procedures, quality assurance, and process data are contained in the Appendixes (Volume II).
Many non-domestic buildings, built recently in the UK, use natural means to provide ventilation for indoor airquality and thermal comfort. This paper presents monitoring results obtained from such a purpose built naturally ventilated educational building. Its performance during the summer is discussed based on monitored results. Using thermal and ventilation modelling, the paper also discusses the optimisation of the building's summer performance. Recommendations on the selection of appropriate ventilation strategies in relation to the prevailing external conditions are derived and the appropriateness of the control methods is discussed. (author)
This report is an appraisal of the state of the European Union`s environment. It was requested by the European Commission as part of the review process of the Fifth Environmental Action Programme `Toward sustainability`. Main sections of the report are headed: societal developments and driving forces; environmental themes and topics; integration economy and environment. Themes covered are: climate change, ozone depletion, acidification, air pollution and quality, waste management, urban-issues, inland water resources, coastal zones and marine waters, risk management, soil quality, and nature and diversity. The main conclusions of this report are that the European Union is making progress towards reducing certain pressures on the environment, though this is not enough to improve the general quality of the environment and represents even less progress towards sustainability. Without accelerated policies, ...
In 2003, Vehicle Emissions Team of the Clean Air Strategic Alliance (CASA) decided to explore ways to reduce vehicle emissions such as particulate matter, nitrogen oxides, carbon monoxide, and hydrocarbons from diesel engines. One of the options for reducing emissions from diesel engines, a diesel particulate filter (DPF), is the subject of a demonstration project to test the effectiveness of the Johnson Matthey diesel particulate filter called Continuously Regenerating Technology (CRT) under cold weather conditions. The project involved filter testing between January 2003 and January 2004 on two diesel buses in Edmonton Transit System's (ETS) fleet. Vehicle exhaust emissions were tested for total hydrocarbons, nitrogen oxides, carbon monoxide, carbon dioxide, and particulate matter. The objectives of the project were to: prove the effectiveness of DPF under cold weather conditions in Alberta; provide an opportunity for hands-on installation experience and ...
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
This report describes the results of work conducted during February 1982 - January 1983. A literature search was initiated to identify the state-of-the-art of NOx (NO + NO/sub 2/) reduction technologies, including NOx measurement methodologies, air infiltration and ventilation trends, the impact of NOx (NO/sub 2/) emissions on health, and airquality standards. As a result of the literature search NOx (NO/sub 2/) reduction goals were established for the project and technologies to achieve these goals identified. This report also covers the development of a prototype burner which examined flue gas recirculation, burner designs, secondary air baffling and flame inserts as potential technologies to reduce NOx (NO/sub 2/). Because of their potential for NOx (NO/sub 2/) reduction shown by initial experiments, an in-depth analysis of ring insert configurations was conducted. These results, along with other ...
A study was conducted to predict indoor ventilation, smoke movement and fire propagation in a new building currently under construction at the Ecole Polytechnique de Montreal. It was conducted in response to concerns regarding the impact that airquality, in normal operation conditions, and smoke concentration, in the event of a fire, may have on occupants of a building. A detailed three-dimensional model of the new building was constructed using the NURBS-based modeler, Rhino. Simulations of fire propagation and airflow ventilation were performed in different areas of the building. The flow pattern data was analyzed using the computational fluid dynamics (CFD) program called FLUENT. It predicted air flow conditions and estimated the mean age of air (MAA) in the room. Real-world geometries, such as diffuser inlets, have a significant impact on overall fluid flow behaviour and are necessary for this type ...
A scaled physical model was operated to simulate steam drive operations in five-spot patterns with reservoir and operational parameters similar to those encountered in California reservoirs. The goal of this study was to elucidate the role of two important controllable parameters, viz., steam injection rate and steam quality and to explore the role of two important factors, oil viscosity and reservoir permeability on the performance of the steam drive. In addition, the influence of bottom water and a basal permeable layer were investigated. The experiments demonstrated that there is an optimum injection rate; that in the vicinity of this optimum an increased quantity results in improved oil steam ratios; that the viscosity of the oil at steam temperature, raised to a fractional power, 0.5, appears to correlate with oil production; that permeabilities in the darcy range have little effect on performance, but an increasing one with low viscosity ...
Sandia is a national security laboratory operated for the U.S. department of Energy by the Sandia Corporation, a Lockheed Martin Company. Sandia designs all non-nuclear components for the nation's nuclear weapons, performs a wide variety of energy research and development projects, and works on assignments that respond to national security threats - both military and economic. They encourage and seek partnerships with appropriate U.S. industry and government groups to collaborate on emerging technologies that support their mission. Today, Sandia has two primary facilities, one in Albuquerque, New Mexico, and one in Livermore, California. They employ about 7,600 people and manage about $1.4 billion of work per year. In 1995, a decision was made to move from their in-house developed systems to commercial software. This decision was driven partly by Y2K compliance issues associated with the existing operating system and support environment. Peoplesoft was ...
Lawrence Livermore, Sandia Livermore and Los Alamos National Laboratories have a joint project to develop an optimized hydrogen fueled engine for series hybrid automobiles. The major divisions of responsibility are: system analysis, engine design and kinetics modeling by LLNL; performance and emission testing, and friction reduction by SNL; computational fluid mechanics and combustion modeling by LANL. This project is a component of the Department of Energy, Office of Utility Technology, National Hydrogen Program. We report here on the progress on system analysis and preliminary engine testing. We have done system studies of series hybrid automobiles that approach the PNGV design goal of 34 km/liter (80 mpg), for 384 km (240 mi) and 608 km (380 mi) ranges. Our results indicate that such a vehicle appears feasible using an optimized hydrogen engine. The impact of various on-board storage options on fuel economy are evaluated. Experiments with an available engine at the Sandia Combustion ...
Lawrence Livermore, Sandia Livermore and Los Alamos National Laboratories have a joint project to develop an optimized hydrogen fueled engine for series hybrid automobiles. The major divisions of responsibility are: system analysis, engine design and kinetics modeling by LLNL; performance and emission testing, and friction reduction by SNL; computational fluid mechanics and combustion modeling by LANL. This project is a component of the Department of Energy, Office of Utility Technology, National Hydrogen Program. We report here on the progress on system analysis and preliminary engine testing. We have done system studies of series hybrid automobiles that approach the PNGV design goal of 34 km/liter (80 mpg), for 384 km (240 mi) and 608 km (380 mi) ranges. Our results indicate that such a vehicle appears feasible using an optimized hydrogen engine. The impact of various on-board storage options on fuel economy are evaluated. Experiments with an available engine at the Sandia Combustion ...
Protecting Earth and planets against the invasion of 'alien life forms' is not military science fiction, but it is the peaceful daily job of engineers and scientists of space agencies. 'Planetary Protection' is preventing microbial contamination of both the target planet and the Earth when sending robots on interplanetary space mission. It is important to preserve the 'natural' conditions of other planets and to not bring with robots 'earthly microbes' (forward contamination) when looking for 'spores of extra terrestrial life'. The Earth and its biosphere must be protected from potential extraterrestrial biological contamination when returning samples of other planets to the Earth (backward contamination). The NASA-Caltech Laboratory for Planetary Protection of Dr. Kasthuri Venkateswaran at the Jet Propulsion Laboratory (JPL) (California, USA) routinely monitors and characterizes the microbes of NASA spacecraft assembly rooms and space robots prior to flight. They ...
This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas well as existing ERP information from 9 ...
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and lighting was 30% of the ...
The Sulphur Bank Mercury Mine (SBMM) is a 65 ha site located on the eastern shore of the Oaks Arm of Clear Lake, Lake County, California. Between 1864 and 1957, SBMM was the site of underground and open pit mining operations for S and Hg, coinciding with past and present hot spr...
Sandia National Laboratories (SNL) is committed to conducting its operations in an environmentally safe and sound manner. It is mandatory that activities at SNL/California comply with all applicable environmental statutes, regulations, and standards. Moreover, SNL/California continuously strives to reduce risks to employees, the public, and the environment to the lowest levels reasonably possible. To help verify effective protection of public safety and preservation of the environment, SNL/California maintains an extensive, ongoing environmental monitoring program. This program monitors all significant effluents and the environment at the SNL/California site perimeter. Lawrence Livermore National Laboratory (LLNL) performs off-site external radiation monitoring for both sites. These monitoring efforts ensure that emission controls are effective in preventing contamination of the environment. As part of ...
Federal and California regulations governing the disposal of sludges and liquid wastes associated with the production of electricity from geothermal resources were evaluated. Current disposal practices, near/far term disposal requirements, and the potential for alternate disposal methods or beneficial uses for these materials were determined. 36 refs., 3 figs., 15 tabs. (ACR)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling ...
A geologic sequestration pilot in the Thornton gas field in Northern California, USA involves injection of up to 4000 tons of CO{sub 2} into a stacked gas and saline formation reservoir. Lawrence Berkeley National Laboratory (LBNL) is leading the pilot test in collaboration with Rosetta Resources, Inc. and Calpine Corporation under the auspices of the U.S. Department of Energy and California Energy Commission's WESTCARB, Regional Carbon Sequestration Partnership. The goals of the pilot include: (1) Demonstrate the feasibility of CO{sub 2} storage in saline formations representative of major geologic sinks in California; (2) Test the feasibility of Enhanced Gas Recovery associated with the early stages of a CO{sub 2} storage project in a depleting gas field; (3) Obtain site-specific information to improve capacity estimation, risk assessment, and performance prediction; (4) Demonstrate and test methods for ...
Significant development of an oil shale industry has been projected over the next few decades. The nation's largest oil shale reserves exist in the Wyoming Basin and Colorado Plateau physiographic provinces. This study presents a brief description of the environmental setting and land-use pattern of the region, with a review of the major environmental issues associated with each proposed technology for extracting shale oil. Serious effects may be expected from the modification of very large land surfaces through open-pit mining and spent-shale disposal. The impacts include habitat destruction, potential species loss, and deterioration of surface and groundwater quality. In situ retorting of shale may result in major alterations of groundwater quantity, quality, and flow regimes. Mine dewatering from in situ retorting requires the disposal of large volumes of highly saline water, threatening the quality of ...
The growing concern of the population with regards to the problem of atmospheric pollution has induced a change in the role of airquality monitoring networks, especially those monitoring air pollution in large cities which suffer from summer smog. The population is no longer satisfied with real-time measurements but wants to be warmed of high pollutants concentrations in advance. Some countries have been forecasting air pollution, and especially ozone, for a large number of years. Although most of them use statistical models based on the analyses of past conditions which induced high pollution episodes, some predict ozone levels using only their knowledge of the meteorological situation. Nowadays two trends appear regarding ozone forecasting: either very basic statistical methods, such as regression, or more sophisticated ones, such as neural networks. The paper then reviews several behaviours common ...
The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Airquality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag er een van is. Het scholencomplex is in ...
In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of ...
This article presents a hands-on web-based activity motivated by the relation between human health and ozone pollution in California. This case study is based on multivariate data collected monthly at 20 locations in California between 1980 and 2006. Several strategies and tools for data interrogation and exploratory data analysis, model fitting and statistical inference on these data are presented. All components of this case study (data, tools, activity) are freely available online at: http://wiki.stat.ucla.edu/socr/index.php/SOCR_MotionCharts_CAOzoneData. Several types of exploratory (motion charts, box-and-whisker plots, spider charts) and quantitative (inference, regression, analysis of variance (ANOVA)) data analyses tools are demonstrated. Two specific human health related questions...
The Network for a Healthy California (Network) employs a Geographic Information System (GIS) to identify the target audience and plan program activities because GIS is a powerful tool for assisting in data integration and planning. This paper describes common uses of GIS by Network contractors as well as demonstrating the possibilities of GIS as a useful tool for public health programs and audience targeting in general. Narrative examples supported with graphics describe how 1) Network contractors use the GIS to identify eligible census tracts to carry out their work, 2) the GIS can map neighborhood assets in eligible census tracts throughout California, 3) the GIS can map health behavior data to the county level throughout California, and 4) the GIS can map selected indicators of healthy ...
This report summarizes all work of the Limited Energy Study, Energy Engineering Analysis Program (EEAP), Fort Hunter Liggett, California, authorized under Contract Number DACA05-92-C-0155 with the U.S. Army Corps of Engineers, Sacramento District, California. The purpose of this study is to develop projects and actions that will reduce facilities energy consumption and operating costs at Fort Hunter Liggett. Implementation of these projects will contribute to achieving the goal of the Army Facilities Energy Plan of a reduction in energy consumption per square foot of building floor area of 20 percent by FY2000 from FY1985 baseline levels.
The quality of fuel oils is discussed. The problems that the fuel oil marketer must deal with that relate to the quality of the fuel oil are described.
More than 30 environmental concerns were analyzed for the transportation of coal by rail, roads (trucks), high voltage transmission lines (that is, from mine-mouth generating plants to distribution networks), coal slurry pipelines, and barges. The following criteria were used to identify these problems: (1) real physical environmetal impacts for which control technologies must be developed, or regulation made effective where control technologies presently exist; (2) the level of impact is uncertain, although the potential impact may be moderate to high; (3) the concerns identified by the first two criteria are specific to or exacerbated by coal transportation. Generic transportation problems are not included. The significant environmental problems identified as a result of this study are: (1) rail transport - community traffic disruption and human health, safety, and habitat destruction; (2) coal haul roads - road degradation, traffic congestion and safety, air ...
The iron smelting performance of brown coal coke is compared to black coal coke in a small experimental cupola furnace with 300 mm internal diameter. Relations between major operational parameters are explained, including coke properties, coke lump size, cupola furnace geometry, air supply and temperature conditions. Thermal efficiency of the furnace, a thermal balance (Sankey diagram) as well as results of 12 smelting tests are described. Smelting results were used to establish a coke assessment diagram with minimum limit lines for coke properties required for satisfactory cupola smelting. The influence of furnace dimensions, horizontal and vertical, is further analyzed in order to derive conclusions on coke suitability for larger industrial cupola furnaces. The performance of brown coal coke types was below the limit of technological quality, all other coke types above the minimum quality level are described as suitable, ...
Passion fruit (Passiflora edulis f. flavicarpa L.) yellow variety is composed of 50-55g peel per 100g of fresh fruit which is discarded as waste during processing. Utilization of passion fruit peel for pectin extraction was studied. Passion fruit peel obtained after juice extraction was blanched in boiling water for 5min, dehydrated in a cross flow hot air drier at 60+-1degreeC to a moisture content of 4g/100g of dried peel. The dehydrated passion fruit peel was used for extraction experiments of pectin. The effect of pH, peel to extractant ratio, and number of extractions, extraction time and temperature on the yield and quality characteristics of pectin were investigated. The optimized conditions for extraction of pectin from passion fruit peel yielded 14.8g/100g of dried peel. Pectin ex...
Two-phase pressure drop and fluctuating static pressures were measured in a small horizontal rectangular channel (hydraulic diameter = 5.44 mm). The two-phase fluid was an air/water mixture at atmospheric pressure tested over a mass flux range of 50 to 2,000 kg/m[sup 2] [center dot] s. Two-phase flow patterns were identified and an objective method was found for determining the flow pattern transition from bubble or plug flow to slug flow. The method is based on an RMS static pressure measurement. In particular, it is shown that the transition is accompanied by a clear and abrupt increase in the RMS pressure when plotted as a function of mass quality. Use of the RMS pressure as a two-phase flow pattern transition indicator is shown to have advantages over pressure-versus-time trace evaluations reported in the literature. The transition is substantiated by a clear local change in slope in the curve of two-phase pressure drop plotted as a ...
The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas in which plant operations may be improved is discussed. 7 ...
Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10{sup -1}. This paper describes our experience in using the IAEA Code of Practice in ...
An overview is given of the interest of the Dutch government, several organizations and consumers in the quality of the indoor environment. Main aspects, sub-aspects and indicators for the indoor environment of dwellings are listed: site selection, thermal comfort, airquality, light, view, privacy, noise, safety, and radiation. [Dutch] In het veld wordt onvoldoende aandacht en prioriteit gegeven aan de kwaliteit van het binnenmilieu. Het ligt voor de hand de kennis over de relatie gezondheid en binnenmilieu bij professionele partijen te vergroten. In dit kader is het Binnenmilieuprofiel voor de kantooromgeving geintroduceerd. Aan de hand hiervan kan de discussie worden gevoerd tussen vrager en aanbieder over de kwaliteit van het binnenmilieu. Het zou de basis kunnen zijn voor een keurmerk Gezond Gebouw. Dezelide binnenmilieuproblematiek doet zich natuurlijk ook voor bij woningen. In dit artikel wordt een introductie ...
Airborne pollutants can cause failures in switching and computing equipment. This paper focuses on a subset of such pollutants - airborne fine particles (<2.5 [mu]m diameter). It begins by examining the extent to which different improvements in heating, ventilating and air conditioning (HVAC) systems reduce indoor concentrations of fine particles. For each modification, the consequent reduction in soiling rate is derived. The concomitant increase in operating costs is also calculated. These costs are then compared with the costs of failures in telephone switching offices, leading to estimates of failure rate reductions that would make improvements cost-effective. Finally, the reduction in failures required to offset the costs of the improvements are compared with documented differences in failure rates between unimproved and improved environments. This study suggests that, in many telephone switching offices, the added operating costs associated with more ...
The consequences of converting a facility from brown coal fuel to gas fuel were analyzed by model simulation. Treated were a district heating plant with an output of 700 TJ/yr and minor local heating sources (stoves) at a density of 1 family house per 100 m"2. Emissions of particulate matter, sulfur dioxide, nitrogen oxides, carbon monoxide, and hydrocarbons before and after the conversion are given for the two types of source. Conversion of a major air pollution source to gas fuel would result in a reduction of the contribution of sulfur dioxide emissions of the order of 10"-"4, of particulate matter and carbon monoxide of the order of 10"-"3, and of hydrocarbons of the order of 10"-"2. The decrease will be lowest for nitrogen oxides, viz. about 40%. Analogous data for local heating sources in towns would be 10"-"5 for sulfur dioxide, 10"-"4 for particulate matter, 10"-"3 for carbon monoxide and hydrocarbons, and roughly one order of magnitude for nitrogen oxides. ...
The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)
Maximum cross-correlation techniques have been used with satellite data to estimate winds and sea surface velocities for several years. Los Alamos National Laboratory (LANL) is currently using a variation of the basic maximum cross-correlation technique, coupled with a deterministic application of a vector median filter, to measure transverse winds as a function of range and altitude from incoherent elastic backscatter lidar data taken throughout large volumes within the atmospheric boundary layer. Hourly representations of three- dimensional wind fields, derived from elastic lidar data taken during an air-quality study performed in a region of complex terrain near Sunland Park, New Mexico, are presented and compared with results from an Environmental Protection Agency (EPA) approved laser doppler velocimeter. The wind fields showed persistent large scale eddies as well as general terrain following winds in the Rio Grande valley.
The important use of nuclear energy in Europe, and in particular in France, has a beneficial impact on the airquality but raises important problems of radioactive waste management. The technical problems encountered by the French government with the dismantling of Superphenix reactor are a good example. Moreover, despite its reassuring talks, the electronuclear industry lobby, particularly powerful, has never been able to propose any satisfactory solution for the elimination of radioactive wastes. This article makes a criticism of the lack of visibility and democratic debate in France about the sensible subject of nuclear waste management. A comparison with the situation in other countries is made. (J.S.)
In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO2 emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM10 and SO2 measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO2 and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationshi...
There is now a scientific consensus that current rates of accumulation of greenhouses gases in the atmosphere will result in significant global warming and climate change. These changes are likely to have important impacts on a wide range of human activities and the natural environment. There has now been a considerable weight of literature published on the impacts of global warming, much of it very recent. This report seeks to summarise the important results, to analyse the uncertainties and to make a preliminary analysis of the feasibility of monetarising these environmental costs. The impacts of global warming are divided into ten major categories: agriculture, forests and forestry, terrestrial ecosystems and biodiversity, hydrology and water resources, sea level rise and coastal zones, energy, infrastructure/transport/industry, human health and airquality, oceans, and cryospheric impacts. The results of major summary reports are analysed, ...
Facility management has long been regarded as a cost reduction measure, but it is also a means of raising the financial worth of a building so that landlords can get higher rents or sell the building at a better price. [German] Lange Zeit wurde Facility Management als eine Massnahme zur Kostensenkung angesehen. Heutzutage zeigt sich immer mehr, dass das Facility Management sehr viel umfassender zu verstehen ist: Der Wert eines Gebaeudes bemisst sich nicht allein an einer niedrigen Kostenquote, sondern er soll umfassend Investoren wie Mietern den hoechst moeglichen Nutzen bringen. Nicht allein der kostenguenstige Betrieb ist entscheidend, sondern der Wert des Gebaeudes muss insgesamt gesteigert werden. (orig.)
Ways of reducing energy consumption in plastics processing are examined. Examples are given which illustrate how the awareness of everyone in the company to energy saving is essential with particular reference to switching arrangements to ensure such things as lights, machinery, compressed air systems are switched off when not needed or run at a lower level where appropriate. An understanding of the various elements of the electricity bill can inform a company`s planning of its operations to take advantage of lower tariffs. Machinery selection both with regard to efficiency of processing, quality of engineering and appropriate size can achieve significant savings and attention to maintenance is important. Fundamental to all aspects of energy saving is the monitoring of energy usage to identify where savings can be made and to evaluate the effectiveness of any measures taken. (UK)
Several studies on individual control of the thermal indoor climate and indoor airquality are discussed. A distinction is made between the effect on health, the effect on comfort and the effect on performance. The underlying mechanisms are examined more closely, and concrete recommendations are made for future design norms. [Dutch] Een aantal studies op het gebied van beinvloeding van thermisch binnenklimaat en binnenluchtkwaliteit wordt besproken. Hierbij wordt onderscheid gemaakt tussen invloed op gezondheid, comfort en prestaties. Vervolgens wordt dieper ingegaan op achterliggende mechanismen en worden concrete aanbevelingen gedaan voor toekomstige ontwerpen.
Ozone is the most important regional-scale air pollutant causing risks for vegetation and human health in many parts of the world. Ozone impacts on yield and quality of crops and pastures depend on precursor emissions, atmospheric transport and leaf uptake and on the plant?s biochemical defence capacity, all of which are influenced by changing climatic conditions, increasing atmospheric CO2 and altered emission patterns. In this article, recent findings about ozone effects under current conditions and trends in regional ozone levels and in climatic factors affecting the plant?s sensitivity to ozone are reviewed in order to assess implications of these developments for future regional ozone risks. Based on pessimistic IPCC emission scenarios for many cropland regions elevated mean ozone lev...
The objective of this study was to provide a framework for land use and resource allocation decisions in the Northeast Coal Block of British Columbia. The area was divided into a number of sites, and information gathered in two main areas, 1) status of the resource base, and 2) resource management/planning/development. A map and physical description of each site is provided as well as such information as - airquality, soils, vegetation, water resources, petroleum and natural gas resources, coal resources, and gravel resources, agricultural resources, timber resources, fisheries and wildlife resources, recreatational and aesthetic (visual) resources. The appendix volume provides a summary of the institutional management framework and approval procedures for all significant resource sectors. Provincial legislation and government acts are identified.
In this paper, the authors investigate the technical and economical aspects of the natural gas injection in non-integrated pig-iron plants using charcoal in the blast furnace. The effects of the natural gas injection concerning the blast furnace flame temperature, charcoal consumption, productively and permeability are analyzed. It was found that the injection is beneficial in many ways, such as in the improvement of the productivity and quality, if the flame temperature is kept within an appropriate range. In the financial-economic project`s evaluation, the cash flow for the natural gas injection was analysed considering two blast conditions: through the drying and oxygen enrichment of the air. A sensibility analysis is presented in which the internal rate of return of the investment varies according to the prices of charcoal and oxygen. 3 refs., 3 figs., 3 tabs
Ag, Cu, and Ni metallizations were inkjet printed with near vacuum deposition quality. The approach developed can be easily extended to other conductors such as Pt, Pd, Au, etc. Thick highly conducting lines of Ag and Cu demonstrating good adhesion to glass, Si, and printed circuit board (PCB) have been printed at 100-200 deg C in air and N2 respectively. Ag grids were inkjet-printed on Si solar cells and fired through the silicon nitride AR layer at 850 deg C, resulting in 8% cells. Next generation inks, including an ink that etches silicon nitride, have now been developed. Multi-layer inkjet printing of the etching ink followed by Ag ink produced contacts under milder conditions and gave solar cells with efficiencies as high as 12%.
This paper details the design of a premixed, swirl-stabilized combustor that was designed and built for the express purpose of obtaining validation-quality data for the development of large eddy simulations (LES) of gas turbine combustors. The combustor features nonambiguous boundary conditions, a geometrically simple design that retains the essential fluid dynamics and thermochemical processes that occur in actual gas turbine combustors, and unrestrictive access for laser and optical diagnostic measurements. After discussing the design detail, a preliminary investigation of the performance and operating envelope of the combustor is presented. With the combustor operating on premixed methane/air, both the equivalence ratio and the inlet velocity were systematically varied and the flame structure was recorded via digital photography. Interesting lean flame blowout and resonance characteristics were observed. In addition, the combustor exhibited ...
At the 7th Healthy Buildings Conference, which was held in Singapore, 7-11 December 2003, more than 500 articles to improve public health and productivity of workers in buildings and the performance of installations. Special attention is paid to indoor airquality and thermal comfort in relation to energy efficiency. [Dutch] Op de laatste Healthy Buildings conferentie, december 2003 in Singapore, werden meer dan 500 artikelen gepresenteerd over het creeren van gezonde, productiviteit verhogende gebouwen en installaties. Deze keer lag de nadruk op binnenluchtkwaliteit en thermisch binnenklimaat, onder andere op het aspect energiezuinigheid. Opvallend was ook de aandacht die de problemen met binnenluchtkwaliteit in ontwikkelingslanden kreeg.
This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.
Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.
As coal becomes more and more important as a power plant fuel in this time of energy shortage and the combustion of high-sulfur coals that would impair airquality, efforts have been made to devise efficient processes to control sulfur dioxide emission. Besides desulfurization before combustion, flue gas desulfurization is considered the most promising method that could also be applicable to all other fossil fuels. In this article, the flue gas desulfurization processes are briefly reviewed, and processes with highest use and with high potential for future use are compared from technical and economical points of view. In the selection of a desulfurization process, it is very important to consider the capacity of the plant, fuel type and fuel-to-sulfur ratio, availability and price of the reagent to be used, type, price, and market of side products, disposal problems of wastes, and environmental factors.
This seminar dealt with the subject of indoor air pollution and welcomed participants from environmental consultancy agencies and authorities and institutions related with environmental protection. Leading scientists from research and authorities presented the current state of knowledge abut the risks of indoorair pollution. The papers contained in these proceedings addressed: room climate and sick-building syndrome; allergens in indoor spaces; pollutants emitted by exemplary building materials; pollutant levels of organic compounds in indoor spaces; airquality in motor vehicle interiors; indoor air pollution - risk assessment and need for actions. (Uhe) [Deutsch] Das Seminar zum Thema Innenraumluft wurde fuer TeilnehmerInnen von Umweltberatungsstellen und anderen mit Umwelt betrauten Behoerden und Institutionen veranstaltet. Fuehrende Wissenschaftlerinnen aus Forschung und Behoerden stellten den ...
A relational database capable of storing and manipulating the large volumes of data on air toxic metals has been developed for the Center for Air Toxic Metals at the Energy and Environmental Research Center (EERC) of the University of North Dakota. The database provides information to researchers, managers, and operations personnel to aid in their decision making and long-term planning of issues related to air toxic metals. A personal computer-based graphical user interface is used to access the data located on a UNIX workstation at the EERC. With security codes and software issued by the EERC and an Internet service provider in place, the database can be accessed externally through the Internet. Currently the database contains over 3000 analytical measurements from nine full-scale systems and several bench-scale operations. Data are available on gas, solid, and liquid stream samples as well as relevant engineering ...
This study was undertaken to determine which rodent species serve as primary reservoirs for the Lyme disease spirochete Borrelia burgdorferi in commonly occurring woodland types...Full Text Available
... poly-chaete densities and diversity values, probably the oyster aquaculture in BF although not intensive has produced a ... faster (DÃaz-Castañeda & Rodriguez-Villanueva 1998). However if oyster aquacultu...
The background for the project of a solar-powered aircraft, designed and built by Dr. Paul McCready of California, is reported with details on the aircraft design and its flight across the English Channel.
To determine who resists sexual assault and what happens, data were examined from a probability sample of 3,132 adult community residents of Los Angeles, California. Seventy-five per cent of the respondents...Full Text Available
This Process Waste Assessment was conducted to evaluate the two largest hazardous waste streams generated on-site at Sandia National Laboratory (SNL)/California -- ``Other Inorganic Solid Waste`` and ``Empty Containers <30 Gallons.``
A prospective cohort study was undertaken in two commercial California dairies. The treatment group, 246 cows, received three doses of a whole cell bacterin of J5 Escherichia coli (mutant of E. coli...Full Text Available
This conference was held December 4--8, 1994 in Asilomar, California. The purpose of this meeting was to provide a forum for exchange of state-of-the-art information concerning the prediction of protein structure. Attention if focused on the following: comparative modeling; sequence to fold assignment; and ab initio folding.
Factors potentially contributing to the lower incidence of Lyme borreliosis (LB) in the far-western than in the northeastern United States include tick host-seeking behavior resulting in fewer human...Full Text Available
The methanogenic community in hydrothermally active sediments of Guaymas Basin (Gulf of California, Mexico) was analyzed by PCR amplification, cloning, and sequencing of methyl coenzyme M reductase...Full Text Available
This course is based upon lectures in physics given by Professor Feynman at the California institute of technology during 1961 and 1962. This volume is dedicated to quantum physics, semiconductors, symmetry and advanced principles of physics.
This article reports of the nickel-metal-hydride battery and its ability to compete with the lead-acid battery in electric-powered vehicles. The topics of the article include development of the battery, the impetus for development in California environmental law, battery performance, packaging for the battery's hazardous materials, and the solid electrolyte battery.
Feb 28, 2001 ... Dr. Ellen Ochoa was born on May 10, 1958 in Los Angeles, CA, but considers Las Mesa, California to be her hometown. She received her ...
Due to the recent catastrophic energy system failures in California along with those in the North-Eastern US and Southern Canada, London, and Italy, the time has come to proclaim the failure of deregulation, privatization or liberalization and propose a new energy system. This book shows in the first section, how five precipitating forces led to the deregulation debacle in California: (1) major technological changes and commercialization, (2) regulatory needs mismatched to societal adjustments, (3) inadequate and flawed economic models, (4) lack of vision, goals, and planning leading to energy failures, and (5) failure and lack of economic regional development. The second half of the book, examines how 'civic market', new economic models, and planning for complexity as sustainable economic development transformed in California, the same five forces to create an 'agile energy system' based ...
particle mass with diameter smaller than 2.5 microns.) Our expectation has been that California's ...... MODIS Aqua and Terra products to visualize the movement of ...... correlation in hydrometeor (cloud and precipitation) occurrence, ...
The Advanced Power Electronics Interfaces for Distributed Energy Workshop, sponsored by the California Energy Commission Public Interest Energy Research program and organized by the National Renewable Energy Laboratory, was held Aug. 24, 2006, in Sacramento, Calif. The workshop provided a forum for industry stakeholders to share their knowledge and experience about technologies, manufacturing approaches, markets, and issues in power electronics for a range of distributed energy resources. It focused on the development of advanced power electronic interfaces for distributed energy applications and included discussions of modular power electronics, component manufacturing, and power electronic applications.
...and welcome to ...lab also known as berkeley lab my name is jeff miller and ...and a public affairs i'd like to ? ...but space is science center and ...berkeley albany high school science department and berkeley high school science department and oakland high school science ...be a q. and ...here please use and because we wanna make sure that your questions are here ...heard of also for the latest developments on science and technology ...guy we're going to be any more and more new features i hope ...and change ...thank you ? much and thank you for coming on the welcome to my world of and mayotte science journalist and what i've done for the last almost thirty years ...people about things about which there passionate and national religion tonight and ...people to explain the science and and i asking the question so what ...and ...worldwide and what it does best ? uh ...bench science and turn it into reality what do you scientists and ...uh they take scientific theory and they turn ...
Numerous laboratory investigations have shown that sulfur dioxide (SO/sub 2/) induces bronchoconstriction and respiratory symptoms in exercising asthmatics. These effects appear to depend on dose rate (the product of exposure concentration and ventilation rate), and may occur at dose rates attainable during outdoor exercise in SO/sub 2/-polluted communities. Effects are rapid in onset, requiring no more than 5 min of exercise during exposure. Thus they may be induced by transient elevations of SO/sub 2/ levels, which may occur near large pollution sources even when longer-term average concentrations meet existing airquality standards. Even very mild asthmatics typically are far more sensitive to SO/sub 2/ than healthy volunteers. The authors discuss an investigation designed to expand and improve the dose-response information on SO/sub 2/. In comparison to earlier work it employed a larger, clinically more diverse population of volunteer ...
Field data for validating plume models were collected in and around the Bull Run Steam Plant during two four-week periods between July and October, 1982. The field measurements were the second phase of the Plume Model Validation and Development (PMV and D) program. The Bull Run Steam Plant is located near Oak Ridge, Tennessee, and the area is described as the ''Moderately Complex Site'' to distinguish it from the ''Plains Site'' in eastern Illinois, which was the scene of the first phase of the PMV and D study conducted in 1980-81. The measurement program consisted of a set of meteorological, source, aerometric, and tracer measurements to track and characterize the plume. The tracer measurements constituted the largest portion of the total effort, and it involved the release of SF/sub 6/ tracer gas from the stack, and the sampling and analysis of nearly 64,000 air samples collected over a test ...
Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between ...
There is a need to reduce air pollutant emissions in some U.S. urban regions to meet federal and state airquality guidelines. Opportunities exist for reducing pollutant emissions from natural gas appliances in the residential sector. A cost-benefit analysis on various pollutant-reducing strategies is needed to evaluate these opportunities. The effectiveness of these pollutant-reducing strategies (e.g., low-emission burners, energy conservation) can then be ranked among themselves and compared with other pollutant-reducing strategies available for the region. A key step towards conducting a cost-benefit analysis is to collect information on pollutant emissions from existing residential natural gas appliances. An extensive literature search was conducted to collect data on residential natural-gas-appliance pollutant emission factors. The literature primarily describes laboratory tests and may not reflect actual emission ...
Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 Building conversion from oil to an environmentally cleaner fuel, natural gas. Existing heaters were removed and an existing ...
There are several concerns which bring to consider natural gas as a viable alternative to liquid fuels in transport. First, natural gas allows the curbing of global pollution in this steadily growing industry. Indeed, decoupling greenhouse gas emissions from transport growth has become a major issue in tackling climate change. Second, a more extensive use of natural gas would relieve city airquality, which is presently at levels harmful of human health. Nonetheless, this is just one side of the coin. The other side entails building a refuelling station network, and this carries financial requirements. The financing fraction holds a pivotal role in deciding whether natural gas for automotive purposes is an efficient solution. The final aim of this work is, therefore, to compare the natural gas advantages, stemming from avoided global and local emission, with the economic rationale of engaging in supplementary model network investments. A system ...
Like other Central European countries, Poland faces the twin challenges of improving environmental quality while also fostering sustainable economic development. In this study we examine the costs of different standards for air pollution control, and the cost savings from using incentive-based policy instruments in lieu of more rigid command-and-control policies. The comparisons are based on the results of a simulation model of energy use and air pollution control for the Polish economy over 1990-2015. The model simulates least-cost energy supply decisions under different environmental policy assumptions, the corresponding emissions, and the cost of achieving the specified policy objectives. The model results suggest that incentive-based policies will have efficiency gains over command policies that are at least worthy of consideration and may be quite substantial. The size of the gains in practice depends in part on how ...
The Geothermal Energy Association ({open_quotes}GEA{close_quotes}) will create and manage a Geothermal Heat Pump ({open_quotes}GHP{close_quotes}) Training Center to deliver GHP and HVAC courses throughout California in response to imminent demand driven by national promotion. GEA services include providing management structure, cadre, curricula, promotion and physical equipment. The Center is dedicated to infrastructure strengthening goals of the Geothermal Heat Pump Consortium, Inc. ({open_quotes}GHPC{close_quotes}), the California Energy Commission ({open_quotes}CEC{close_quotes}) and Interagency Geothermal Heat Pump Task Force, and Geothermal Energy Association ({open_quotes}GEA{close_quotes}). Second-half 1996 start-up is co-funded by GHPC, CEC, GEA and three California utilities. Initial support is to five utilities representing 70 percent of California power users. Goals include becoming market ...
Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available
This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining ...
What kind of lesson do we get from California situation? The first is that the sufficient investment to the operational regulation should be prepared as a system. It is necessary to introduce the systems related to capacity, such as the capacity market system that makes retail suppliers secure the fixed rate of their running peak-load as reserve capacity and other system that secure the 5-year supply capacity by a contract, in which suppliers can pay the penalty if they purchase more capacity than in the contract. The second is that the supplementary measures should be systematized for the supply system not to be in a panic in a case of the shortage situation of equipment. The exchange authority should control the regular inspection program on generators to reduce the market control of the supply companies. Through the supplementary system, the increase of electricity price must make the demand decrease. According to the current plan, it will be take a long time to ...
Developing markets in the Pacific Basin depend heavily on the production and export of consumer goods. The generation of hazardous waste as a by-product of industrial production can be linked to adverse health outcomes, such as childhood leukemia, in ways that are presently unknown. In California, exposures resulting from hazardous waste disposal are of concern in the etiology of childhood cancer. Approximately 63% of the 57 hazardous waste sites that the U.S. Environmental Protection Agency (USEPA) included in the national priority list under the Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) statute were in the six-county San Francisco Bay area. This area includes California`s Silicon Valley, where a disproportionate majority of these sites are located. Although only one study links hazardous waste disposal to childhood leukemia evidence is accumulating that in utero and maternal pesticide exposures as well as ...
Clean Water Act You are here: Water Laws & Regulations Policy & Guidance Clean Water Act Water Quality and 401 Certification Water Quality and 401 Certification Water Quality...
The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain very low concentrations of radioisotopes. The ...
An automated Time Resolved Aerosol Collector (TRAC) has been developed for sequential sampling of field-collected aerosols for laboratory-based Computer Controlled Scanning Electron Microscopy/Energy Dispersed X-ray (CCSEM/EDX) single particle analysis. The collector is optimized for use of grid-supported 20 nm carbon films as deposition substrates. The carbon films have low enough X-ray background to permit EDX analysis down to 0.1-0.2 ?m particles, including detection of low-Z elements: C, N, & O. The TRAC provides unattended sampling onto a set of 151 individual grids, at sequential time intervals as short as 1 min. After collection, the samples are sealed and refrigerated pending analysis. The utility of the TRAC-CCSEM/EDX approach is exemplified using the aerosol samples collected during the Texas 2000 AirQuality Studies (Aug. 15 ? Sept. 15, 2000). We are able to quantitatively follow the time evolution in the relative contribution of ...
In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO{sub 2} emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM{sub 10} and SO{sub 2} measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO{sub 2} and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationship for SO{sub 2} and PM{sub 10} emissions. Therefore, the results of our time series and panel data analyses do not support the ...
In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO2 emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM10 and SO2 measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO2 and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationship for SO2 and PM10 emissions. Therefore, the results of our time series and panel data analyses do not support the Environmental Kuznets Curve hypothesis, ...
In this study, we investigate the relationship between income and environmental quality for Turkey at two levels. First, the relationship between the CO{sub 2} emissions and per capita income is examined by the help of a time series model using cointegration techniques. In the second stage, the relationship between income and air pollution is investigated by using PM{sub 10} and SO{sub 2} measurements in Turkish provinces. In this part of the study panel data estimation techniques are utilized. The time series model covers 1968-2003, and the panel data model covers 1992-2001 including observations from 58 provinces. A monotonically increasing relationship between CO{sub 2} and income is found in the long-run according to time series analysis. On the other hand, panel data analysis indicates an N-shape relationship for SO{sub 2} and PM{sub 10} emissions. Therefore, the results of our time series and panel data analyses do not support the ...
A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor airquality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.
Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in relation to the forms of space and water heating utilized. Daily ...
In the United Kingdom several educational buildings were built in the last decades with a strong environmental ethos, real icons of a new generation of low-energy sustainable buildings. For some of the buildings the performance was assessed. Also in the Netherlands several new concepts were developed for sustainable schools during the last years. This is an interesting topic as many of those schools had problems concerning energy efficiency, indoor airquality and thermal comfort. In the case of sustainable schools much effort was put into the design process of the schools to try to find better solutions to face the problems of the traditional designs. This resulted in different solution concepts, which raises the question which are better school concepts. From the literature three evaluations from the UK and one overview of five sustainable educational buildings from the Netherlands are given, which show that sustainable educational buildings ...
Results are presented from studies on the quality of cast parts made by counterpressure casting of high-strength aluminum alloy AMKh-605, and Al-Cu-Mn-Cr alloys (5.6-6.4% Cu, 0.25-0.55% Mn, 0.20-0.55% Cr, 0.20-0.45% Ti, 0.08-0.25% Zr, less than or equal to0.25% Fe, less than or equal to0.25% Si, less than or equal to0.05% Mg). Chill castings were heat treated by quenching from 450/sup 0/C (20 hours) in water, aging at 160/sup 0/C for five hours with cooling in air. Fractograms of tensile specimens are presented. Scanning electron microscopy allows an ambiguous determination of the cause of failure of a part, be it at initial crystallization crack defects or burns, and also allows a relationship to be established between structure and mechanical properties.
Coal bed natural gas (CBNG) development in the Powder River (PR) Basin produces modestly saline, highly sodic wastewater. This study assessed impacts of wetting four textural groups (0-11%, 12-22%, 23 -33%, and > 33% clay (g clay/100 g soil) x 100%))with simulated PR or CBNG water on water retention. Soils received the following treatments with each water quality: a single wetting event, five wetting and drying events, or five wetting and drying events followed by leaching with salt-free water. Treated samples were then resaturated with the final treatment water and equilibrated to -10, -33, -100, -500, or -1,500 kPa. At all potentials, soil water retention increased significantly with increasing clay content. Drought-prone soils lost water-holding capacity between saturation and field capacity with repeated wetting and drying, whereas finer textured soils withstood this treatment better and had increased water-retention capacity at lower matric potentials.
The effects on engine emissions resulting from the intake manifold fumigation of oxygenated fuel and the addition of oxygenates to the fuel have been investigated using a direct-injection diesel engine. The results show that carefully selected oxygenated fuels effectively work to increase the ignition delay because of their low ignition quality and to decrease the combustion temperature due to the low compression gas temperature produced from their large heat of vaporization, thereby reducing levels of Bosch smoke and nitrogen oxides simultaneously. However, supplementary injection of the oxygenates into the intake air causes a drastic increase in the levels of exhaust total hydrocarbons and CO; thus, it can be said that the addition of oxygenates to the fuel is more practical and effective than fumigation if phase separation of the blended fuel may not be occurred. In the case of addition of the oxygenates to the fuel, it is clarified that ...
This presentation gives the results of a research programme aimed at evaluating exhaust emissions from ships moving within confined coastal zones, as in Piraeus harbour. The level of various exhaust emissions were estimated on the basis of a mathematical model applied for each sea traffic element (ship). Hourly and daily records of all ships` movements in different parts of the harbour were compiled, covering extended periods of time and associated with different shipping operational characteristics (peaks, lows, etc). In order to correlate the exhaust emissions from shipping with the quality of the air in the area of interest, land-based measurements for the same pollutants were carried out in selected locations, near the port and in the greater Athens area. This enabled the investigation of time and spatial diffusion of exhaust emissions from shipping within the area of interest, taking into account the influence of prevailing meteorological ...
The aim was to investigate conditions relating to the substitution of natural gas for part of the amount of cinders previously used as fuel in an existing cupola furnace used in an iron foundry. The process of retrofitting is described. The principle solution is that four gas burners are placed symmetrically around the furnace immediately above the melting zone. They are mounted in separate fire boxes in such a way that they point downwards in order to prevent the fire box being filled with materials from the furnace, which would cause damage to the burners. The burners are continuously controlled to produce an output of 720 - 2620 kW and with 0.5 - 1.5 excess air. This solution was successful although it was found necessary (in order to achieve a satisfactory quality of resulting molten material) to add extra cinders to the furnace resulting in a reduction of only 9% of total cinders used, instead of the hoped-for 15%. The melting temperature ...
"7Be produced by the interaction of cosmic rays with oxygen and nitrogen, predominantly in the stratosphere, has been used to identify and measure stratospheric ozone at the ground level. Simultaneous measurements at Whiteface Mountain, New York, in July 1975 show that the maximum "7Be concentrations are accompanied by increased ozone concentrations. Peaks in "7Be concentrations occurred on July 5-6, 11-12, 16-17, 23, and 27. Ozone peaks were observed on July 7-9, 11, 18, 24, and 27. Isentropic trajectory calculations also showed that the trajectories reaching Whiteface Mountain on July 11-12, 15-16, 23, and 27 had stratospheric origin. One-day delay in ozone peaks on July 7-9, 18, and 24 is attributed to increased tropospheric ozone production. The observed relationship between "7Be and ozone is used to deduce an upper limit of 37 ppb stratospheric ozone at Whiteface Mountain during July 1975. Thus, even during midsummer months, when stratospheric-tropospheric mass exchange is not at ...
A radio frequency sputtering apparatus with a pair of targets has been developed for depositing a film of uniform thickness onto a complex-geometric specimen such as the retainer of a ball bearing. The deposition characteristics of the apparatus were compared with those of the conventional sputtering apparatus. Lubrication properties of MoS/sub 2/ films made by these devices were also compared under a variety of conditions. Finally, friction and wear of MoS/sub 2/ films applied to angular-contact type ball bearings of 20 mm bore were studied in air, nitrogen and vacuo. The two-target sputtering has an advantage mentioned above. However, the films deposited by the method exhibited a rather short wear life because of the temperature rise of the substrate during ion bombardment and during the sputtering process. This temperature dependence was observed in films on those substrates that had been heated with a built-in heater during sputtering. The film thickness ...
The insulating oil used in a transformer is a critical component, as its service life is typically 20 years with possibly little or no maintenance. Partial discharges (PD), thermal overloads and static discharges continually subject the oil to chemical deterioration during its operating life. To ensure equipment reliability during service, it is important that the initial quality of the new insulating oil should meet the required acceptance specifications and preferably be pre-tested before use. Accelerated aging tests have been devised to determine the life expectancy of oil in service by using forced air or oxygen flow into the oil, the presence of a copper catalyst, and at elevated temperatures. The more important standards relating to transformer application are discussed and highlights of the more important aspects of the oxidation chemistry of hydrocarbons are included. The ultimate aim of the project is the formulation of better standard ...
In October last year the first intercomparison of measurements of the soil radon concentrations between various laboratories in Slovakia was realised. The organisation of this intercomparison was conducted by the Slovak Legal Metrology in Banska Bystrica together with the Slovak National Accreditation Service in Bratislava (SNAS). The scientific guarantee of the exercise was the State metrological Centre for radon quantities, which is working at the Research base of Slovak Medical University in Bratislava. The main objective of the intercomparison was to verify the correctness of the methods for the soil radon measurements of the authorised laboratories for radon volume activities in soil air. The intercomparison (signed as SLM ILC 3/03) was performed as a 'circular' metrology comparison, in accordance with a methodical directive MSA 0117-98, published by SNAS. Six laboratories were participating on the intercomparison and there have been two stages of the work one ...
The increasing diffusion of small-scale energy systems within the distributed generation (DG) paradigm is raising the need for studying the environmental impact due to the different DG solutions in order to assess their sustainability. Addressing the environmental impact calls for building specific models for studying both local and global emissions. In this framework, the adoption of natural gas-fueled DG cogeneration technologies may provide, as a consequence of cogeneration enhanced overall energy efficiency and of natural gas relatively low carbon content, a significant reduction of global impact in terms of CO2 emissions with respect to the separate production of electricity and heat. However, a comprehensive evaluation of the DG alternatives should take into account as well the impact due to the presence of plants spread over the territory that could increase the local pollution, in particular due to CO and NOx, and thus could worsen the local air ...
Deteriorating airquality in urban areas is leading bus manufacturers to look for cleaner drives of urban buses. Various new systems are now available, but it is difficult to compare them and verify their effects without having a driving cycle accurately representing contemporary average urban bus use. The idealized form (engine cycle, passenger car cycle or different kW/tonnes ratio and traffic conditions) of existing driving cycles disqualifies them for the purpose. For this reason, it was decided to attempt the development of a new driving cycle for urban buses. To this end, measurements were carried out on buses in service in four major Dutch towns. The resulting data were combined to produce a reference cycle comprising all data relating to urban bus use. Statistical methods were then used to compare a large number of 15-20 minute cycles with this reference cycle, until one was found that corresponded closely to the reference cycle. 5 ...
Resource coordination and interference management is the key to achieving the benefits of femtocell networks. Over-the-air signaling is one of the most effective means for distributed dynamic resource coordination and interference management. However, the design of this type of signal is challenging. In this letter, we address the challenges and propose an effective solution, referred to as coded single-tone signaling (STS). The proposed coded STS scheme possesses certain highly desirable properties, such as no dedicated resource requirement (no overhead), no near-and-far effect, no inter-signal interference (no multi-user interference), low peak-to-average power ratio (deep coverage). In addition, the proposed coded STS can fully exploit frequency diversity and provides a means for high quality wideband channel estimation. The coded STS design is demonstrated through a concrete numerical example. Performance of the proposed coded STS is ...
The report was prepared for the IPCC by Working Group II. The remit of Working Group II was to describe the environmental and socioeconomic implications of possible climate changes over the next decades caused by increasing concentrations of greenhouse gases. The scenarios used include the following features: an effective doubling of atmospheric CO{sub 2} between now and 2025-2050; a consequent increase of global mean temperature of 1.5-4.5{degree}C; an unequal global distribution of the temperature increase; a sea level rise of 0.3 to 0.5m by 2050. The impacts of possible climate change were assessed for the following: agriculture and forestry; natural terrestrial ecosystems; hydrology and water resources; human settlements including the energy, transport and industrial sectors; human health; airquality and changes in UV-B radiation; oceans and coastal zones; seasonal snow cover; ice and permafrost. Further action is recommended. 1015 refs., ...
Compact heat exchangers have traditionally found wide application in the transportation industry, where they are used as evaporators and condensers in vapor compression cycles for air conditioning and refrigeration. Such heat exchangers possess numerous attractive features including high thermal effectiveness, small size, low weight, design flexibility, and pure counterflow, and they can accommodate multiple streams. Today, there is a widespread interest in expanding the range of application of compact heat exchangers to include phase-change heat transfer in the process industries, among others. An overall objective of this effort is to provide the basis for establishing design technology in this area. In the present study, small channel flow boiling heat transfer was extended to a rectangular channel (4.06 {times} 1.70 mm) using refrigerant 12 (R-12). As with the circular tube studies, the flow channel wall was electrically heated providing a constant heat flux. ...
An X-ray fluorometric train was set up for analyzing gravitational fallout, and tested on standard reference samples of fly ashes from conventional power plants. Analysis of thin layers proved inappropriate, and therefore pelletization of the samples, either alone or together with the X-ray MIX binder, was applied. Sample grinding in an agate mortar was found sufficient to suppress the particle size effect. The optimum pressure was 20 MPa. The optimum geometry was sought for "1"0"9Cd source, and limits of detection of 2.78-0.47 #mu#g were achieved for Cr-Zr elements. Tominaga's method was employed for matrix effect correction. Ti, Fe, Cu, Zn, As, Rb, Sr, Zr and Pb were determined in the SRM's; the relative errors ranged from units per cent (for Zn, Rb, Sr and Zr present in concentrations about 100 ppm and for Fe in concentrations of units per cent) up to 45% (for Ti present in a concentration of 0.67%). The method developed was applied to the investigation of fallout in the town of ...
Since the beginning of the large-scale technical manufacture of activated charcoal at the start of the century, this product has become increasingly important. Activated charcoal is a central part today of many chemical industrial processes. Furthermore, the purification of exhaust air and liquid wastes is often based on the adsorption by activated charcoal. The constantly increasing hygienic demands made of our drinking water may also often only be fulfilled by using activated charcoal. The highly developed adsorption technique of today is considerably supported by continuous improved quality of the products which can only be achieved by progress in manufacturing techniques. The large-scale use of activated charcoal has only become possible for a series of tasks by developing suitable reactivation methods. The last German-language monograph on activated charcoal appeared 18 years ago. The present work wishes to close this gap and in particular ...
This study reviews the wireline log responses of some geothermal fields in the Imperial Valley, California. The fields under study include the Heber, the East Mesa, the Brawley, and the Westmoreland. The well logs used in the study did not include all the wireline surveys obtained by the operators. The selected well logs obtained under special arrangements with the operators were chosen to maintain the anonymity of specific well locations but are only representative of each area. Analysis of the well logs indicates that on an individual field basis, the well logs are excellent for correlation purposes. The presence of extremely saline fluids in some fields precludes the monitoring of Q/sub v/ (cation exchange capacity per unit volume) profile for detection of hydrothermally altered zones. The producing sections in all the fields are characterized by low porosity and high resistivity.
Given the concern over the potential for health risks associated with certain ingredients (e.g., phthalates) in personal care products, usage patterns of 30 types of personal care products (e.g., shampoo, sunscreen, fragrance, etc.) were collected in 604 California households through a telephone interview. Preferences in selecting products, e.g., scented or unscented, aerosol, and brand loyalty, were also investigated. Participants were recruited in three age groups, children (mostly preschoolers), their parents, and adults age 55 or older. Use frequencies of various product types varied by sex, age group, race, education, and climatic region. Product use by parent and child from the same household were correlated. Use frequencies of products in the same class (e.g., skincare) were moderat...
Seasonal and habitat calliphorid abundance and distribution were examined weekly for two years (2001-2003) in Santa Clara County, California, using sentinel traps baited with bovine liver. Of the 34,389 flies examined in three defined habitats (rural, urban, and riparian), 38% of the total catch represented Compsomyiops callipes (Bigot) and 23% represented Phormia regina (Meigen). Other flies collected in this survey included Calliphora vomitoria (Linnaeus), Calliphora latifrons (Hough), Lucilia sericata (Meigen), Lucilia cuprina (Wiedemann), and Lucilia mexicana (Macquart), which is a new record for the area. Multivariate MANOVA and ANOVA (P 0.05) analysis indicate significant seasonal habitat preference for all fly species examined. This information may be used to identify potentially fo...
This report is the result of field work performed at the former White Point Nike Missile Site, San Pedro, California. The Hazardous Waste Remedial Actions Program tasked the Oak Ridge National Laboratory Pollutant Assessments Group in Grand Junction, Colo., with this project. The objective was to determine whether or not radioisotopes possibly associated with past Department of Defense (DOD) operations were present and within accepted background levels. The radiation survey was accomplished by performing three independent radiation surveys, both outdoors and indoors, and random soil sampling. Initially, the site was land surveyed to develop a grid block system. A background radiation investigation was performed out in the San Pedro area.
Crustal xenoliths (pyroxenites and plagioclase + quartz + pyroxene lithologies) from the Quaternary Big Pine volcanic field on the eastern flank of the Sierra Nevada Batholith in California (USA) represent the products of metasomatic reaction between the margins of a Cretaceous granodioritic pluton and Paleozoic marbles, possibly at mid-crustal depths based on the equilibration temperatures recorded by Ti-in-quartz geothermometry. This interpretation is based on the presence of plagioclase showing relict plutonic textures, pyroxenite characterized by nearly pure diopside clinopyroxene, recrystallized plagioclase with anomalously high anorthite content, textures indicating replacement of plagioclase by clinopyroxene (and vice versa), `ghost' plagioclase rare earth element signatures in some...
Microreserves may be useful in protecting native arthropod diversity in urbanized landscapes. However, species that do not disperse through the urban matrix may eventually be lost from these fragments. Population extinctions may be precipitated by an increase in genetic differentiation among fragments and loss of genetic diversity within fragments, and these effects should become stronger with time. We analyzed population genetic structure in the dispersal limited Jerusalem cricket Stenopelmatus n. sp. ?santa monica?? in the Santa Monica Mountains and Simi Hills north of Los Angeles, California (CA), to determine the impacts of fragmentation over the past 70 years. MtDNA divergence was greater among urban fragments than within contiguous habitat and was positively correlated with fragment ...
One of the more extensive uses of directional drilling anywhere in the world has been in the development of the East Wilmington Oil Field in Long Beach, California. The Measurement-While-Drilling (MWD) directional system has been tested on several wells and proven to provide the required accuracy, along with many advantages over past methods, used in the field development. Accurate transmission by MWD of bottom-hole measurements to the surface is provided by mud pressure pulses generated in the drill pipe downhole and detected by a pressure transducer includes the means for detecting, recording and processing these pressure pulses, to translate the information from the pressure pulses to rig floor displays usable by the drilling crew. 2 refs.
The commercialization of geothermal energy resources consists of a sequence of exploration, development, and utilization activities. Each of these activities are beset by both generic and project specific technical, environmental, and institutional constraints which must be adequately resolved before geothermal operations can be conducted. This report presents a summary of selected environmental activities conducted during the early planning stages of geothermal resource commercialization. Three representative activities are elaborated upon. These include preliminary environmental planning for geothermal energy development in the Medicine Lake Highlands of California; potential alternatives for non-electric use of the geothermal resource at East Mesa in Imperial County, California; and site specific studies of the impacts from using East Mesa geothermal fluids to irrigate selected crops and indigenous climax vegetation.
Plants require solar radiation for photosynthesis and their growth is directly related to the amount received, assuming that other environmental parameters are not limiting. Therefore, precise estimation of photosynthetically active radiation (PAR) is necessary to enhance overall accuracies of plant growth models. This study aimed to explore the PAR radiant flux in the San Francisco Bay Area of northern California. During the growing season (March through August) for 2?years 2007?2008, the on-site magnitudes of photosynthetic photon flux densities (PPFD) were investigated and then processed at both the hourly and daily time scales. Combined with global solar radiation (R S) and simulated extraterrestrial solar radiation, five PAR-related values were developed, i.e., flux density-based PAR ...
The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 and 25 % were observed. Due to its compactness and ruggedness ...
A community greenhouse gas emission and energy inventory is an important tool to help local governments plan, implement and monitor climate change mitigation strategies and sustainable energy systems. Inventories can also facilitate a number of other local priorities such as airquality management; integrated land-use and transportation planning; infrastructure optimization and planning; and community economic development planning. The British Columbia government's community energy and emissions inventory initiative (CEEI) intends to collect and centralize high-quality geocoded data to generate high-value community inventories for the province's 185 local governments. This report presented strategic guidance for a comprehensive community emissions inventory system based on a high level review of international best practices. The report described the project objective and scope; guiding principles; research methodology; and ...
The environmental impacts of uranium mining and milling activities are of great concern in many countries for the last three decades. These impacts range from the creation of massive stockpiles of radioactive and toxic waste rock and sand-like tailings to serious contamination of surface and groundwater with radioactive and toxic pollutants, and releases of conventional, toxic and radioactive air pollutants. Uranium mining is also associated with high concentrations of highly toxic heavy metals, which are a major source of surface and groundwater contamination. Depending upon the hydraulic properties of the fractures involved, contaminated ground water may be transported many miles from its point of origin before feeding into an aquifer. Tailings pond may contaminate the groundwater regime by continuous seepage and leaching of radionuclides and other toxic metals due to interaction of rain water through the tailings ponds. The uranium milling and tailings pond ...
The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribboned channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermo viewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of 2,116 kg/cm{sup 2}, (2) mass fluxes of 40 to 70 kg/m{sup 2} s, (3) heat fluxes of 4,500 to 7,300 W/m{sup 2}, (4) inlet quality of 0.1 to 0.7. The results ...
In 2004, the Southeastern France regional council asked the regional health observatory to conduct an environmental health inventory to i) identify environmental health problems in this area; ii) examine the relations between environmental exposure to pollutants and human health; and iii) help public officials to identify priorities in this area. We collected and validated data from national, regional and local institutions, constructed environmental (levels of emissions and pollutants), health (mortality, incidence, prevalence) and behavioral indicators (e.g., complaints about odors), and compared these over time and between places when possible. For each topic, we summarized current knowledge about the links between environment and health. In southeastern France, as in other French areas, indoor air pollution, home and leisure injuries and other home-related risks are public health issues. Other topics are more significant or particular to southeastern France: ...
Nitrite was measured in atmospheric liquid phase samples between 1998 and 2005 to investigate the heterogeneous formation of nitrous acid in the lower atmosphere, as well as to assess the quality of water recovered from dew. The samples were collected during ground-based cloud field experiments at different German mountain sites (Brocken, Schmucke, and Hohenpeissenberg) and at a site south of the Bordeaux urban area (France). Concentrations found in Bordeaux dew samples (up to 2800 ?gl-1) are comparable to those found elsewhere in urban fog and dew water and considerably higher than those detected in cloud water or rain. Particulate nitrite (and nitrate) as well as HNO2 (HNO3) data in air masses from a foothill site of Mt. Schmucke, before involved in cloud processing, are also presented. In clouds at Mt. Brocken, both the interstitial HNO2 gas and the aqueous phase nitrite concentration have been measured simultaneous. Significant deviations ...
More than two and a half years of monitoring of a passive house school and day-care centre in Frankfurt a. M. show comfortable indoor climate and good airquality. The space heat consumption is low and shows savings of approximately 90 % as compared to average existing schools. Excellent performance was also achieved in terms of primary energy. The results of further analyses of the efficient ventilation system with heat recovery, the perimeter insulation as an alternative to floor slab insulation and the influence of the air change due to the entrance door are presented. (Abstract Copyright [2008], Wiley Periodicals, Inc.) [German] Ueber zweieinhalb Jahre Monitoring einer Passivhaus-Schule und Kindertagesstaette (KiTa) in Frankfurt a.M. zeigt behagliche raumklimatische Bedingungen bei guten Luftqualitaeten. Die Heizwaermeverbrauchswerte liegen wie erwartet niedrig und zeigen Einsparungen um 90 % gegenueber dem Durchschnitt ...
With the advance of science, rise of public interest in environmental matters, and continuing erosion of airquality, Federal and state regulators are demanding an increasing complex array of data concerning emissions produced by burning and detonating energetic materials. The US Department of Defense, one of the world`s largest consumers of energetic materials, now must characterize combustion products resulting from open burning/open detonation disposal operations. The catch-all phrase ``below detection limits`` no longer satisfies the regulators who now want testing to delve into the ppt level for volatile organic compounds and ppt level for semivolatile organic compounds. Regulators are also expanding their scope of interest and may soon be asking for emissions data on training operations such as artillery firing. Providing this type of information is no longer an impossibility. The Army, as the single manager of conventional munitions for ...
Stream temperature is an important physical characteristic of headwater streams that plays a critical role in the presence and health of juvenile salmonids. Headwater stream temperature was documented in two geomorphic settings on the Kenai Peninsula, Alaska, focusing on the variation in temperature induced by diffuse groundwater discharge and variable air temperature. Eighteen headwater stream reaches were studied in four watersheds, with 11 drainageway sites and seven discharge-slope sites. In drainageway sites, low-gradient streams flow through broad valleys with groundwater-fed fen wetlands; in discharge-slope sites, high-gradient streams flow through narrow valleys with groundwater-fed slope wetlands. At all 18 sites, hourly stream temperatures were measured for one year. At one drainageway and one discharge-slope site, groundwater temperatures, stream stages, and groundwater heads in the local groundwater flow systems were also measured hourly for a year. A ...
Hydroperoxides are important atmospheric oxidants. They are responsible for most of the oxidation of aqueous-phase SO(sub 2) to sulfate in the northeastern United States, resulting in the formation of acid precipitation and visibility-reducing sulfate aerosol (Penkett et al., 1979; Lind et al., 1987; Madronich and Calvert, 1990; Tanner and Schorran, 1995). Atmospheric hydrogen peroxide (H(sub 2)O(sub 2) or HP) is produced by the self-reaction of hydroperoxyl radicals (HO(sub 2)); higher organic peroxides are produced by reaction of HO(sub 2) with alkylperoxyl radicals (RO(sub 2)). Peroxyl radicals, along with OH, are chain carriers in the complex photochemical process that produces tropospheric ozone. Thus, concentrations of peroxides and their free radical precursors depend on solar intensity and ambient concentrations of water vapor, ozone, NO(sub x) (NO+ NO(sub 2)), and VOCs (volatile organic compounds). Several investigators have demonstrated that HP and hydroxymethyl hydroperoxide ...
The zinc-air battery/fuel cell is an old technology invented one hundred years ago. However, there is renewed interest in this technology in response to the growing need for clean energy technology. The zinc-air battery/fuel cell is more attractive than similar technologies because its characteristics include high power density, safe operation and storage, and low cost. Zinc-air battery/fuel cells can be made in milliwatts to mega watts to accommodate different applications. The zinc-air battery/fuel cell has four major designs, namely primary, mechanically rechargeable, continuous feed and electrically rechargeable zinc-air battery/fuel cells. Among the different designs, the most common is the air cathode. There are 3 generations of catalysts used in the air cathodes. This paper discussed the different designs of the ...
The staff of the Southwest Technology Development Institute (SWTDI), in conjunction with the staff of Industrial Solar Technology (IST), have analyzed the performance, operation, and maintenance of a large solar process heat system in use at the 5,000 inmate California Correctional Institution (CCI) in Tehachapi, CA. This report summarizes the key design features of the solar plant, its construction and maintenance histories through the end of 1991, and the performance data collected at the plant by a dedicated on-site data acquisition system (DAS).
Reports by U.S. workers on geodetic measurements of recent plate motions or crustal deformation published in 1987-1990 are reviewed. The review begins with global plate motions, proceeds through plate boundaries in California, Alaska, and the Pacific Northwest, and finishes with volcanic phenomena, monument stability and longevity, and GPS relative position measurements. 184 refs.
Based upon these processes-phytoextraction, phytovolatization and phytostabilization-a plant management remediation strategy for selenium (Se) has been developed for the Westside of Central California. Multi-year field phytoremediation studies were conducted between 2002-2007 on Se-tainted field si...
The Gulf of California represents one of the most productive and unique marginal seas in the world. The mouth of the Gulf captures warm equatorial water while annual wind patterns assure major upwelling of nutrient-rich water leading to a rich marine biota. These conditions have created a wide array of tropical through warm temperate carbonate environments. The most unusual of these environments is located in the La Paz region of Baja California Sur where tropical-subtropical water temperatures and low rainfall have allowed growth of corals, calcareous red algae, and other shelled invertebrates to form a carbonate bank environment. Sampling and mapping transacts in shallow bays north of La Paz and on the adjacent Espiritu Santo island have revealed a full spectrum of subenvironments including mangrove bordered, terrigenous mud dominated coastal zones, which grade into carbonate tidal flats. In addition, single coral heads as well as incipient ...
... Studies People Projects Opportunities Framework Critical Sectors Development Goals Geographic Region Geographic Scale Research Themes Printer-Friendly Center for Ocean Solutions Early Career Fellowship Program Location: Stanford, California Source: The Center for Ocean Solutions (“Ocean Solutions”) seeks one or more recent graduates who have received a JD, MBA or PhD in the natural, physical or social sciences in the last five years, and who ...
In an effort to accelerate deployment of Distributed Energy Resources (DER) such as wind, solar, and conventional backup generators to our nation's electrical grid, Northern Power Systems (NPS), the California Energy Commission (CEC), and the National Renewable Energy Laboratory (NREL) collaborated to create a prototype universal interconnect device called the DER Switch.
The effects of upwind turbine wakes on the performance of a FloWind 17-m vertical-axis wind turbine (VAWT) were investigated through a series of field experiments conducted at the FloWind wind farm on Cameron Ridge, Tehachapi, California. From the field m...
From nuclear science symposium; San Francisco, California, USA (14 Nov 1973). A digital Fourier analyzer was programmed to perform reactor neutron noise analysis measurements and on-line processing of the data to obtain the steady-state reactivity. The system is suitable for recovering cross spectral density with low correlatedsignal component and for repetitive measurements with efficient use of reactor time. (auth)
The engineering and economic feasibility of using the geothermal resources in East Mesa, California, in a new corn processing plant is evaluated. Institutional barriers were also identified and evaluated. Several alternative plant designs which used geothermal energy were developed. A capital cost estimate and rate of return type of economic analysis were performed to evaluate each alternative. (MHR)
Three book reviews and five essays address the problems of governing coastal regions. The books reviewed and the articles covered the institutions and programs involved in resource management, the balance of local and state interests in coastal conservation and developments, a consensus on coastal planning issues, and a growing trend in state-local collaborative planning. Four of the articles pertain to California, and one focuses on programs in Maine, Rhode Island, and Washington. 135 references. (DCK)
Qualitative and quantitative techniques, including a telephone survey of 310 Taiwanese business owners, were used to study the unique features of Taiwanese immigrant businesses in Los Angeles (California). When provided with entrepreneurial capital, Taiwanese enterprises grow rapidly in the context of Los Angeles's economic restructuring. (SLD)
... However, Hydrogen Energy is working towards establishing hydrogen-fired power generation facilities in other parts of the world (e.g. California, Abu Dhabi and elsewhere) and the synergies work carried out for the Kwinana proposal would provide a good starting basis for other proposals. ...
The Lawrence Livermore National Laboratory (LLNL) is establishing a local chapter of the University of California Energy Institute (UCEI). In order to most effectively contribute to the Institute, LLNL sponsored a workshop on energy and environmental issues in transportation. This workshop took place in Livermore on August 10 and brought together researchers from throughout the UC systems in order to establish a joint LLNL-UC research program in transportation, with a focus on energy and environmental impacts.
In May 1995, the California Public Utilities Commission (CPUC) released two proposals for restructuring the state`s electric power industry. The two proposals follow more than a year of testimony and public comment after the CPUC issued the ``Blue Book`` (CPUC 1994a) on April 20, 1994, which called for retail wheeling to be phased in to all customers over 5 years. The majority proposal, supported by three of the four CPUC commissioners (one seat was vacant when the proposals were released), calls for creating a central pool, or ``poolco``; setting electric prices to reflect true costs of service, or ``real-time pricing``; and allowing parties to negotiate ``contracts for differences`` between the pool price and the contract price. The minority proposal, sponsored by Commissioner Jesse Knight, calls for retail wheeling, or ``direct access,`` and for utilities to divest or spin off their generating assets. This paper presents a summary of the major provisions of the ...
Rising oil prices are a problem for the motor car industry. Now, an ambitious project has been launched in California which may become a serious competitor to gasoline and diesel engines: The Tesla Roadster, which is fuelled from simple wall sockets. (orig.)
A plan has been put forth to strategically thin northern California forests to reduce fire danger and improve forest health. The resulting biomass residue, instead of being open burned, can be converted into ethanol that can be used as a fuel oxygenate or an octane enhancer. Economic potential for a biomass-to-ethanol facility using this softwood biomass was evaluated for two cases: Stand-alone and co-located. The co-located case refers to a specific site with an existing biomass power facility owned by Wheelabrator Environmental Systems Inc. near Martell, California. A two-stage dilute acid hydrolysis process is used for the production of ethanol from softwoods, and the residual lignin is used to generate steam and electricity. For a plant processing 800 dry tonnes per day of feedstock, the co-located case is an economically attractive concept. Total estimated capital investment is approximately $ 70 million for the co-located case. The ...
The Petroleum Technology Transfer Council (PTTC) and cooperating Regional Lead Organizations (RLOs) in its South Midcontinent (Oklahoma Geological Survey, Norman, Oklahoma) and West Coast (University of Southern California, Los Angeles, California) regions conducted a ''Mentor-Based Effort to Advance Implementation of Preferred Management Practices (PMPs) For Oil Producers'' (DE-FC26-01BC15272) under an award in Phase I of Department of Energy's (DOE's) PUMP (Preferred Upstream Management Practices) program. The project's objective was to enable producers in California, Oklahoma and Arkansas to increase oil production, moderating or potentially reversing production declines and extending the life of marginal wells in the near term. PTTC identified the primary constraints inhibiting oil production through surveys and PUMPer direct contacts in both regions. The ...
In the paper presented, an attempt is made to describe quantitatively the room air motion by diffuse air distribution. Since solving the problem theoretically, seems to be hopeless at present, only an experimental solution seems to promise success. Experiments with diffuse air distribution offer suitable preconditions. With this kind of air introduction into the room, a relatively regular distribution of room air motion can be expected. A further simplification will be achieved by isotherme flow conditions. The first goal of the experiments was to establish whether the velocities measured are reproducible to demonstrate, and can be brought into a functional connection. The room air motion is a measured value which changes temporarily and locally quite largely, far more than is customary with technical measurements. From there, a second task arises, i.e. to ...
This guidebook concerns the design of air-conditioning and air-treatment installations in recent and old buildings. The design of indoor atmosphere treatment systems is based on a rigorous and safe methodology. The following aspects are reviewed: situation of ambient air treatment, different aspects of a project, humid-air technique, principles of air treatment, basic conditions for a successful project, determination of enthalpy and hydric loads of rooms, design of ambient treatment systems, cold water production using a thermodynamical system, aeraulics, hydraulics, acoustics, logics of operation, forecasting of energy consumptions, global management of air-conditioning installations, ambient air-treatment systems. (J.S.)
In Hungary, legislation for nuclear power plants was developed at the end of the 1970s, among which is the quality assurance code for nuclear power plants. Hungarian practice is presented, including discussion of the requirements for quality assurance, qualification of the suppliers and inspection practices. The general requirements of quality assurance in the course of construction of a nuclear power plant are presented: quality assurance of technological equipment, fuel, electrical equipment, automatic instrumentations, building structures and technology.
Space HVAC systems are to provide hygienical room air. Air change is necessary because of pollutants released from materials or production processes but also because of the presence of humans or animals who consume oxygen. Poor room climate and/or poor air hygiene do not only reduce the felt comfort but may also result in a loss or profitability and higher sickness rates. (orig.)
for? Learn the Issues Science & Technology Laws & Regulations About EPA Contact Us Water: Water Quality Criteria You are here: Water Science & Technology Surface Water Standards &...
BackgroundThe aim of this study is to validate the questionnaire ECOS-16 (Assessment of health related quality of life in osteoporosis) for the evaluation of health related quality...Full Text Available
This report presents results from the soil inorganic analysis of the 44th set of environmental quality assessment samples, of the quality assessment program, that were received on or before June 3, 1996. The samples were analyzed for RCRA metals.
Quality reporting tools, integrated with ambulatory electronic health records, can help clinicians and administrators understand performance, manage populations, and improve quality. Report Central...Full Text Available
The status of the concept of controlling the quality of physicians is reviewed as are studies that have been done on methods to measure and improve quality. The conclusions are dismal given the rhetoric...Full Text Available
Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)
The causality of observed associations between air pollution and respiratory health in children is still subject to debate. If reduced air pollution exposure resulted in improved respiratory health...Full Text Available
Studies of the associations between air pollution and hospital admissions and emergency room use are reviewed, including studies of air pollution episodes, time-series analyses, and cross-sectional...Full Text Available
The invention concerns an integrated nuclear reactor comprising natural convection cooling of the supporting skirt on which rests the shield closing the reactor vessel. Cooling is achieved by making the air circulate from the bottom to the top around the skirt and removing this air by a stack. The air can be atmospheric air or air taken from the low parts of the reactor. In the latter case, the stack emerges near a metal roof releasing its heat to the atmosphere by radiation, the air then dropping to the low parts. Application to fast nuclear reactors.
The key component for improving the energy efficiency and cycle life of the electrically rechargeable zinc-air battery is the bifunctional air electrode. The air electrodes described in this paper contained different types of carbon black as the substrate for the perovskite catalyst (La{sub 0.6}Ca{sub 0.4}CoO{sub 3}). Morphological and physical properties of the carbon substrates play an important role in enhancing the activity and stability of the bifunctional air electrode. Current-potential curves and cycle-life tests were applied in order to gather information on the activity and stability of these electrodes. (authors)
The `Procurement Quality Function` is an element of the Body of Knowledge of Quality Engineering, as defined by the American Society for Quality Control (ASQC). This paper describes the Procurement Quality function which has been installed as an integral part of the Quality Engineering group of the Technical and Management Support Services (T&MSS) contractor to the United States Department of Energy (DOE) Yucca Mountain Site Characterization Project. Each of the elements of the T&MSS Procurement Quality Engineering (PQE) system is discussed along with the measurements obtained. With the installation and development of the PQE system we have attained more meaningful evaluation of supplier capability, reduction of procurement document review reject ratios from 31% to less than 2% per quarter, more effective measurement and control of supplier performance, ...
... tests, one often encounters, for instance, separated flows with large ... It is suspected that the flow-quality criteria given in AGARD Report No. ...
BACKGROUND: This prospective and retrospective study carried out over a period of one month (50 patients) looked at the quality of hospital records of urethral catheterisation with reference to the...Full Text Available
Amphibians are considered reliable indicators of environmental quality. In the western United States, a general decline of frog populations parallels an apparent worldwide decline. The factors thought...Full Text Available
As controlled clinical vocabularies assume an increasing role in modern clinical information systems, so the issue of their quality demands greater attention. In order to meet the resulting stringent...Full Text Available
The following aspects will be discussed: The main function of the Division of Inspection Services and its role in the Marketing of agricultural products; the shelf life of agricultural products: short review of present methods with a practical example of losses incurred due to limited keeping quality; irradiation and heat treatment: advantages of inhibited microbiological activities and undesirable chemical changes from a quality control point of view; quality standards: the basic principles of quality control; consequences of effective post-harvest treatment: export of deciduous and citrus fruit; the magnitude of the problem of poor keeping quality and quality requirements; other fruit; quantities and export limitations and vegetables; quantity and quality requirements; local marketing: fruit and vegetables subjected to inspection; quantity ...
Full text: A semiempirical algorithm for absorbed dose calculation at off-axis points in irregular beams was implemented. It is well known that semiempirical methods are very useful because of their easy implementation and its helpfulness in dose calculation in the clinic. These methods can be used as independent tools for dosimetric calculation in many applications of quality assurance. However, the applicability of such methods has some limitations, even in homogeneous media, specially at off axis points, near beam fringes or outside the beam. Only methods derived from tissue-air-ratio (TAR) or scatter-maximum-ratio (SMR) have been devised for those situations, many years ago. Despite there have been improvements for these manual methods, like the Sc-Sp ones, no attempt has been made to extend their usage at off axis points. In this work, a semiempirical formalism was introduced, based on the works of Venselaar et al. (1999) and Sanz et al. ...
Engine flow simulation was provided by four separately mounted air ejectors connected to a high-pressure air supply. The engine nacelle center lines were ...
... Title : The Numerical Weather Prediction System at the Italian Air Force Weather Service: Impact of Non-Conventional Observations and Increased ...
... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...
The main purpose of this report is to document the benchmarking results and verification of the RESRAD-OFFSITE code as part of the quality assurance requirements of the RESRAD development program. This documentation will enable the U.S. Department of Energy (DOE) and its contractors, and the U.S. Nuclear Regulatory Commission (NRC) and its licensees and other stakeholders to use the quality-assured version of the code to perform dose analysis in a risk-informed and technically defensible manner to demonstrate compliance with the NRC's License Termination Rule, Title 10, Part 20, Subpart E, of the Code of Federal Regulations (10 CFR Part 20, Subpart E); DOE's 10 CFR Part 834, Order 5400.5, ''Radiation Protection of the Public and the Environment''; and other Federal and State regulatory requirements as appropriate. The other purpose of this report is to document the differences and ...
Full text: Pink bollworm (PBW), Pectinophora gossypiella (Saunders), an introduced pest from Mexico, first occurred in United States cotton production in Texas in 1917. Unacceptable economic losses have occurred. The development of PBW sterile moth release technology, gossyplure sex pheromone behavioral control, cotton plant cultural control to reduce overwintered PBW populations, and the transfer of the insect toxin protein gene into cotton from Bacillus thuringiensis kurstaki (Berliner) have provided an effective integrated pest management (IPM) system with PBW eradication potential. Sterile insect release was considered a potential option for PBW population suppression in the early 1960s. Research on the isolated island of St. Croix, (US Virgin Islands) demonstrated its validity. Reductions of larval infestations in bolls following sterile moth releases began when ratios of released PBW sterile male to native male moths averaged 70:1 in gossyplurebaited traps. Numbers of larvae per ...
This study compares the attitudes of academic and government wetlands scientists about wetlands science and policy. Analysis of one thousand seven hundred responses to Delphi-type questions posed to twenty California scientists on a wide range of issues about California coastal wetlands found significant differences between academic and government scientists about wetlands definitions, threats to wetlands, wetlands policies, wetlands health, and wetlands mitigation strategies. These differences were consistent with descriptive models of political sociology developed by D. Price and C.P. Snow and with normative models of the philosophy of science developed in the renaissance by F. Bacon and R. Descartes. Characteristics, preferences, and personality attributes consistent with group functions and roles have been described in these models. These findings have serious implications for policy. When academic and government wetlands scientists act as ...
Thermal gradients and thermal conductivities were obtained in real time using an in situ heat-flow technique in 15 shallow (90 to 150 m) wells drilled between Brawley and Glamis in the Imperial Valley, Southern California. The in situ measurements were supplemented by follow-up conventional temperature logs in seven of the wells and by laboratory measurements of thermal conductivity on drill cuttings. The deltaic sedimentary material comprising the upper approx. 100 m of the Salton Trough generally is poorly sorted and high in quartz resulting in quite high thermal conductivities (averaging 2.0 Wm/sup -1/ K/sup -1/ as opposed to 1.2 to 1.7 for typical alluvium). A broad heat-flow anomaly with maximum of about 200 mWm/sup -2/ (approx. 5 HFU) is centered between Glamis and East Brawley and is superimposed on a regional heat-flow high in excess of 100 mWm/sup -2/ (> 2.5 HFU). The heat-flow high corresponds with a gravity maximum and partially with a minimum in ...
Building 922 houses all of SNL/California`s ES and H Departments: Health Protection, Environmental Protection, Safety, and Environmental Operations. It covers approximately 10,000 square feet and houses about 80 people. The office personnel generate nonhazardous solid office wastes in their daily activities. To determine the types and amounts of waste generated, a special PPOA sorting team sorted all of the trash collected from the building for a period of one-week (including paper and aluminum cans in the recycling bins). The team sorted the trash into major categories: paper, plastic, metals, glass, wet garbage, rest room waste, and miscellaneous materials. They then sorted it into subcategories within each major category. Rest room waste was collected but not sorted. The waste in each category was weighed separately. The total amount of trash collected during the week was approximately 168.8 kg (371.4 lbs). The results of this PPOA indicate that ...
The health politics and policy communities are still struggling with the question of "what went wrong" in the 1993-94 health care reform effort. Here I identify which Americans were politically active and inactive during the health care reform debate to explore the role political participation may have had in determining the outcome of the debate. Using data from a national and California random-sample telephone surveys, and controlling for other demographic attributes, I found that those who engaged in political activity specifically related to health care reform were disproportionately more likely to be self-identified conservatives, less likely to favor an employer mandate plan, more likely to be fifty to sixty-four years old, more likely to be men, and more likely to have greater interest in and knowledge of the health care issue. Even in California, where a single-payer proposal was on the November ballot, self-identified liberals were no ...
The University of California at Los Angeles (UCLA) participated in a U.S. Nuclear Regulatory Commission research program to investigate methods to measure the effect of management and organization on nuclear plant safety. The UCLA research team focused its efforts on understanding {open_quotes}deep technical knowledge,{close_quotes} and its relation to probabilistic risk assessment. As a result, the research team combined deep technical knowledge with a commonly used rating system for understanding the effectiveness of management and organizations.
Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.
Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.
This article describes version 3.006 of Nuance, an advanced and freely available neutrino generator written by Dave Casper of University of California, Irvine. Source codes of the program are publicly available. This description is based on Dave Casper's article '' The Nuance Neutrino Physics Simulation and the Future '', http://nuint.ps.uci.edu/nuance/files/ nuancenuint01.pdf , Nuance website at http://nuint.ps.uci.edu/ nuance/ , README.txt file provided in the src folder of Nuance distribution, and my own experience as a Nuance user. (author)
This workshop covered the latest practical engineering and operational management applications and techniques that have been found to enhance operational costs, reliability, and flexibility, with topics such as establishing the optimal refrigeration design cycle and operating design points; utility management; manpower scheduling; plant control philosophy and automation; short and long term maintenance scheduling; refrigerant loss detection and control; system contamination; component reliability; and equipment technical performance issues.
The symposium, Polycrystalline Thin Films - Structure, Texture, Properties, and Applications III, was held at the 1997 Materials Research Society Spring Meeting on March 31--April 4 in San Francisco, California. The topics and investigations were interdisciplinary in nature, and ranged from fundamental to technological. Specifically, the work presented in this volume includes film growth, texture and structural evolution, phase transformation, characterization of grain boundaries and interfaces, stress analysis, and works on polycrystalline Si and SiGe films and devices. Fifty four papers were processed separately for inclusion on the data base.
The symposium, Polycrystalline Thin Films - Structure, Texture, Properties, and Applications III, was held at the 1997 Materials Research Society Spring Meeting on March 31--April 4 in San Francisco, California. The topics and investigations were interdisciplinary in nature, and ranged from fundamental to technological. Specifically, the work presented in this volume includes film growth, texture and structural evolution, phase transformation, characterization of grain boundaries and interfaces, stress analysis, and works on polycrystalline Si and SiGe films and devices. Fifty four papers were processed separately for inclusion on the data base.
A method based on cluster analysis techniques is proposed in order to obtain representative local wind patterns. Modeling renewable energy systems, in an accurate way which strongly depends on wind loads, requires reliable data to analyze their response and evaluate their performance. Otherwise poor agreement with the models may be obtained. In a case study for La Paz, Baja California Sur, Mexico, four different wind patterns were obtained from a one-year data set recorded at 10-min intervals. (author)
The purposed project is a commercial-scale ethanol-fuel facility with a capacity of twenty million gallons per year of fuel-grade ethanol. In addition, 70,000 tons per year of distillers dried grains will be produced. The following tasks and issues are addressed: process engineering - process descriptions, plant layout, and design; economics and finance - overview of capital and operating costs; environmental analysis - preliminary project description; and permit processing and legal issues. (MHR)
This article outlines the use of gasifiers during World War II and how, with soaring fuel prices, producer gas may provide an alternate energy path for agribusiness and farms today. In the last few years, the University of California has become a focus of producer gas research in the US. Biomass fuels used include crushed walnut shells, fruit pits, cereal straw and corn cobs. Particle size, moisture content and slagging create problems and the right kind of gas producer must be used to obtain reliable conversion to producer gas.
...assistantship in Suburban Ecology Location: Bedford, NY Deadline: August 15, 2008 Postdoctoral Fellow in energy Location: University of Waterloo, Ontario, Canada Deadline: August 11, 2008 Junior Professional Fellowship Sustainable Development Governance Programme Location: UNU, Yokohama, Japan Deadline: August 1, 2008 Center for Ocean Solutions Early Career Fellowship Program Location: Stanford, California Deadline: July 15, 2008 Asian MetaCentre for Population and Sustainable Development Analysis Postdoctoral Research Fellow Location: Singapore Deadline: July 15, ...
FuelCell Energy in Connecticut has sold 4.5 MW worth of power plants to California renewable energy company BioFuels Fuel Cells, part of New Energy Capital and BioFuels Energy. Three molten carbonate fuel cell power plants - a 2.8 MW DFC3000 unit, a 1.4 MW DFC1500 system, and a 300 kW DFC300 unit - will be installed at three locations in the San Diego area, and utilize purified biogas from the Point Loma wastewater treatment plant as their primary fuel source.
Sufficient discussion of the elements of the leasing and permitting programs is included to place the information developed in proper context. A table and process flow diagram developed previously which outline the steps in the non-competitive leasing process, is reprinted. Computer printout profiles are presented on 195 identifiable areas in the following states: Arizona, California, Colorado, Idaho, Montana, Nevada, New Mexico, Oregon, Utah, Washington, and Wyoming. Sufficient information on the boundaries of these areas is contained in the report to permit identification of their general location on any map of the appropriate state which shows township and range locations.
The SY-101 Equipment Removal System 100 Ton Hydraulic Trailer was designed and built by KAMP Systems, Inc. Performance of the Acceptance Test Procedure at KAMP`s facility in Ontario, California (termed Phase 1 in this report) was interrupted by discrepancies noted with the main hydraulic cylinder. The main cylinder was removed and sent to REMCO for repair while the trailer was sent to Lampson`s facility in Pasco, Washington. The Acceptance Test Procedure was modified and performance resumed at Lampson (termed Phase 2 in this report) after receipt of the repaired cylinder. At the successful conclusion of Phase 2 testing the trailer was accepted as meeting all the performance criteria specified.
According to the California Earthquake Authority, only about 12% of current California residences are covered by any form of earthquake insurance, down from about 30% in 1996 following the 1994, M6.7 Northridge earthquake. Part of the reason for this decreasing rate of insurance uptake is the high deductible, either 10% or 15% of the value of the structure, and the relatively high cost of the premiums, as much as thousands of dollars per year. The earthquake insurance industry is composed of the CEA, a public-private partnership; modeling companies that produce damage and loss models similar to the FEMA HAZUS model; and financial companies such as the insurance, reinsurance, and investment banking companies in New York, London, the Cayman Islands, Zurich, Dubai, Singapore, and elsewhere. In setting earthquake insurance rates, financial companies rely on models like HAZUS, that calculate on risk and exposure. In California, ...
The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants.
The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.).
The present code requirements on quality assurance as well as the present praxice of quality assurance procedures in the operation of nuclear power plants are presented. On the example of recurring inspections the organizational and technical complications are shown with respect to the code and licensing requirements. Taking the present experiences into account suggestions are given how to transform the general requirements of KTA 1401 to quality assurance requirements during plant operation. (orig.).
Large volumes of woodwaste disposal by incineration in a number of wigwam burners are contributing to pollution problems in Williams Lake, British Columbia. In 1985, the latest year for which data are available, total woodwaste production was about 800 million bd ft equivalent; only about 14% of this was used for energy recovery. In addition, about 66,000 m/sup 3/ of waste was sent to landfills after open burning. The characteristics of the local woodwaste are summarized, and available conversion technologies and the potential application of their products are reviewed. These include direct combustion, pyrolysis, gasification, liquefaction, and densification, for use in power generation, cogeneration, and the manufacture of saleable products. Environmental and legal aspects of woodwaste utilization are also outlined. Finally, options for reducing pollution from existing burners are reviewed. One option is the upgrading of existing burners; however, it is noted that there are inherent ...
Two-phase flow patterns and frictional pressure gradients in flow in small, rectangular channels are being studies as part of a larger research program addressing phase-change heat transfer of pure refrigerants and refrigerant mixtures in plate-fin heat exchangers. Small rectangular flow channels were selected as representative of plain fin geometries. The particular channel reported herein has dimensions of 19.05 {times} 3.18 mm. Adiabatic flows of air/water mixtures, with the flow channel horizontal and the channel exit at near-atmospheric conditions, were utilized in the experiments. Analysis and interpretation of the pressure data relative to observed flow pattern transitions led to an objective method for determining the plug/bubble-to-slug flow transition. This method, together with visual observations, supplemented with photographic data, was used to develop a flow pattern man. A comparison of existing flow pattern maps for circular pipes, capillary tubes, ...
This paper bundles 40 contributions by the IceCube collaboration that were submitted to the 30th International Cosmic Ray Conference ICRC 2007. The articles cover studies on cosmic rays and atmospheric neutrinos, searches for non-localized, extraterrestrial {nu}{sub e}, {nu}{sub {mu}} and {nu}{sub {tau}} signals, scans for steady and intermittent neutrino point sources, searches for dark matter candidates, magnetic monopoles and other exotic particles, improvements in analysis techniques, as well as future detector extensions. The IceCube observatory will be finalized in 2011 to form a cubic-kilometer ice-Cherenkov detector at the location of the geographic South Pole. At the present state of construction, IceCube consists of 52 paired IceTop surface tanks and 22 IceCube strings with a total of 1426 Digital Optical Modules deployed at depths up to 2350 m. The observatory also integrates the 19 string AMANDA subdetector, that was completed in 2000 and extends IceCube's reach to ...
In February 2001, the Minister of Environment Canada outlined a series of measures to be implemented over the next decades to reduce emissions from vehicles, engines and fuels. The agenda includes the development of new regulations under the authority of Part 7, Division 5 of the Canadian Environmental Protection Act (CEPA) to align Canada's emission standards for on-road vehicles with those of the United States Environmental Protection Agency. This paper presents a detailed summary of comments received by the interested parties that appeared at a public consultation in November 2001 to discuss and raise issues about the proposed regulations. The parties that provided submissions included: governments; the vehicle and engine manufacturing industry; the oil industry; other groups of associations such as the Canadian Trucking Alliance, David Suzuki Foundation, and West Coast Environmental Law; and, five private individuals. The report presents comments and replies from each ...
During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. However, due to mass ...
The ternary compound CuInS{sub 2} is attractive for solar cells due to its band gap of 1.54 eV which borders the optimum value necessary for conversion of a solar spectrum. Recently, works on thin film cells based on this material (ZnO/CuInS{sub 2}) has been reported to show efficiency as high as 11.4%. In this paper, the orientation and the morphology of CuInS{sub 2} sprayed films are determined by the means of X-ray diffraction and scanning electron microscopy. Sprayed CuInS{sub 2} films deposited onto a transparent Pyrex substrate with standard fabrication parameters show a chalcopyrite structure with a preferential orientation (1 1 2). A model based on the calculation of the relative dielectric function {epsilon} has been performed in order to obtain the profile of variation of this parameter and to understand the optical behavior of this material via its transmittance and reflectance in visible and near-infrared regions (0.35-2.5 {mu}m). In the same way, considering the ...
The ternary compound CuInS2 is attractive for solar cells due to its band gap of 1.54 eV which borders the optimum value necessary for conversion of a solar spectrum. Recently, works on thin film cells based on this material (ZnO/CuInS2) has been reported to show efficiency as high as 11.4%. In this paper, the orientation and the morphology of CuInS2 sprayed films are determined by the means of X-ray diffraction and scanning electron microscopy. Sprayed CuInS2 films deposited onto a transparent Pyrex substrate with standard fabrication parameters show a chalcopyrite structure with a preferential orientation (1 1 2). A model based on the calculation of the relative dielectric function ? has been performed in order to obtain the profile of variation of this parameter and to understand the optical behavior of this material via its transmittance and reflectance in visible and near-infrared regions (0.35-2.5 ?m). In the same way, considering the inhomogeneous material CuInS2 containing ...
Formaldehyde, a well-identified indoor pollutant, was recently classified as carcinogenic. New regulations for the airquality are expected and therefore there is a need for low-cost sensors, sensitive and selective with a fast response time for the detection of formaldehyde at ppb level. In the present work, we had developed a chemical sensor based on nano-porous matrices doped with Fluoral-P and optical methods of detection. The nano-porous matrices, elaborated via the Sol-Gel process, display nano-pores whose cavity is tailored for the trapping of the targeted pollutant. They provide a first selectivity with the discrimination of the pollutants by their size. A second selectivity is obtained with a molecular probe, Fluoral-P, which reacts specifically with formaldehyde leading to the 3,5- di-acetyl-1,4-dihydro-lutidine (DDL). The kinetics of formation of DDL was studied as function of many parameters such as the concentration of Fluoral-P in ...
We present a proof-of-concept analysis of the measurement of the health damage of ozone (O_3) produced from nitrogen oxides (NO_x=NO+NO_2) emitted by individual large point sources in the eastern United States. We use a regional atmospheric model of the eastern United States, the Comprehensive Airquality Model with Extensions (CAMx), to quantify the variable impact that a fixed quantity of NO_x emitted from individual sources can have on the downwind concentration of surface O_3, depending on temperature and local biogenic hydrocarbon emissions. We also examine the dependence of resulting O_3-related health damages on the size of the exposed population. The investigation is relevant to the increasingly widely used 'cap and trade' approach to NO_x regulation, which presumes that shifts of emission over time and space, holding the total fixed over the course of the summer O_3 season, will have minimal effect on the environmental outcome. By ...
The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient AirQuality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including the following: (1) R and P Sequential FRM ...
In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective transportation systems, parking, inter-region ...
To realise the Dutch objectives of energy saving and emission reductions in the built environment, the use of 'Low Valued Energy' will be necessary in the future. Low Valued Energy is available from residual, ambient heat and renewable sources. Using Low Valued Energy for space heating in commercial and residential buildings requires adjusting the design of the installations, i.e. lowering the design supply temperature of the heating system from 90C to 55C or less. Appropriate heat distribution systems, e.g. floor or wall heating and radiators, have a life cycle of 40 to 50 years. The application (on a large scale in buildings), however, requires an enormous change in the installation and building branch. To enable the application of low temperature sources in the future, the building and installation designs should be based on low temperature distribution systems. Being aware of this need, a broad implementation programme has been drawn up in the Netherlands for Low ...
This report describes the progress made during this reporting period of a two year project to demonstrate that the air pollution from a traveling grate stoker being used to heat water at a central heating plant in Krakow, Poland can be reduced significantly by (1) substituting the unwashed, unsized coal currently being used with a mechanically cleaned, double-sized stoker fuel and by (2) optimizing the operating parameters of the stoker. It is anticipated that these improvements will prove to be cost effective and hence be adopted by the other central heating plants in Krakow and indeed, throughout Eastern European cities where coal continues to be the primary source of fuel. EFH Coal Company has formed a partnership with two Polish institutions -- MPEC, a central heating company in Krakow, and Naftokrak-Naftobudowa, preparation plant designers and fabricators, for the execution of this effort. The washability data from a 20mm x 0.5mm size fraction of raw coal from ...
This report describes the progress made during the second Quarter of a two year project to demonstrate that the air pollution, from a traveling grate stoker being used to heat water at a central heating plant in Krakow Poland, can be reduced significantly by replacing the unwashed, unsized coal now being used with a mechanically cleaned, double sized stoker fuel and by optimizing the operating parameters of the stoker. It is anticipated that these improvements will prove to be cost effective and hence be adopted in the other central heating plants in Krakow and indeed throughout Eastern European cities where coal is the primary source of heating fuel. EFH Coal Company has formed a partnership with two Polish institutions -- MPEC a central heating company in Krakow and Naftokrak-Naftobudowa, preparation plant designers and fabricators for this effort. The washability data from a 20mm x 0.5mm size fraction of raw coal from the Staszic Mine were evaluated. The data ...
An experimental study was performed to provide the combustion and emission characteristics resulting from fuel-reactivity controlled compression ignition (RCCI) combustion mode utilizing dual-fuel approach in a light-duty, multi-cylinder diesel engine. In-cylinder fuel blending using port fuel injection of gasoline before intake valve opening (IVO) and early-cycle, direct injection of diesel fuel was used as the charge preparation and fuel blending strategy. In order to achieve the desired auto-ignition quality through the stratification of the fuel-air equivalence ratio ( ), blends of commercially available gasoline and diesel fuel were used. Engine experiments were performed at an engine speed of 2300rpm and an engine load of 4.3bar brake mean effective pressure (BMEP). It was found that significant reduction in both nitrogen oxide (NOx) and particulate matter (PM) was realized successfully through the RCCI combustion mode even without ...
The industrial application of anaerobic digestion is a relatively new, yet proven waste treatment technology. Anaerobic digestion reduces and upgrades organic waste, and is a good way to control air pollution as it reduces methane and nitrous gas emissions. For environmental and energy considerations, anaerobic digestion is a nearly perfect waste treatment process. However, its economic viability is still in question. A number of parameters - type of waste (solid or liquid), digester system, facility size, product quality and end use, environmental requirements, cost of alternative treatments (including labor), and interest rates - define the investment and operating costs of an anaerobic digestion facility. Therefore, identical facilities that treat the same amount and type of waste may, depending on location, legislation, and end product characteristics, reveal radically different costs. A good approach for evaluating the economics of ...
Due to the high investment and operation costs incurred by dryers up to 50% of the proceeds from the cultivation of medicinal plants have to be spent on drying. This study was conducted in order to determine whether these costs can be lowered when solar energy is used. As little is known about the drying behaviour of medicinal plants even today one selected sage and camomile in order to study the influence of temperature, relative humidity, and drying air velocity on drying time and drug quality. Laboratory results were used as a basis for developing a solar hothouse dryer for medicinal plants which uses the whole roof surface as solar collectors with a batch dryer set up within the hothouse. In contrast to dryers of this type used up to now a foil green house with a gable roof was used. Installation of a central heating system helps to avoid bottlenecks, allows drying at night and increases plant flow by a factor of 3. The cost of heating oil, ...
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. ...
In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m{sup 2} were installed to provide heating for the covered area of 460 m{sup 2}. The floor heating coil pipes were made of high-quality pure copper with the dimension of {phi} 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the whole heating period, the solar fraction was 56%. According to the performance analysis of the system with ambient parameters, ...
The aim of this work is to compile an inventory of the main characteristics (chemical, morphological, mineralogical and grain size parameters) of the bulk cargo materials and of the material emitted during different port operations for possible use as tracers of the fugitive PM emission sources. For all cases, the tracer characteristics determined for each bulk material were also identified in the corresponding PM material emitted. This inventory could assist the harbour authorities to identify the origin of high PM events recorded by airquality monitoring networks in harbour areas, and could also help modellers to predict the impact of harbour activities on ambient PM levels. The harbour of Tarragona (north-east Spain) was selected for this study given the high volume of solids in bulk handled. To this end, 12 handling operations of selected materials (clinker, phosphate, pyrite ash, Mn mineral, fine Si-Mn, coke (coal), bituminous coal, ...
Tanzania has recently developed a comprehensive environmental policy which has put high priority on several specific environmental issues. One of the issues is the quality of waste water. A special priority is given to the pollution from the sisal industry. The East-African agro-industries generate very large quantities of organic residues from production and processing of different crops. These residues form a major contribution to the pollution of air, soil and waterways, but, at the same time they constitute a large potential for production of bioenergy through anaerobic digestion as well as potential substrate for other biological fermentation processes. Generally, these residues are regarded as having no or very little value and the different disposal methods are mainly a matter of getting rid of the waste. The generation of residues are very often concentrated on few large units, which makes the exploitation of these resources feasible in ...
The work of this association is cut according to 6 axes. Three publications: radiological quality of marine and continental waters of the Normandy coast (synthesis 1997 and 1998); preliminary study of the iodine 129 distribution in the environment of the reprocessing plant of La Hague with terrestrial moss (Homalotecium sericeum); radiological surveillance of the aquatic environment of the nuclear facilities on the area of La Hague (1997 and 1998). The second axis concerns the radiation protection with a campaign of radon measures in a school of the Vire rural district (june 1999). The third part is devoted to the radioecology with the surveillance of radioactivity in the aquatic continental environment of nuclear facilities and the radioecological surveillance (1999) of the building site of Cogema la Hague in the area of tidal range of the Moulinets cove. The fourth part concerns the radioactive waste and environment, with the study of the distribution of the ...
One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)
It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.
In-situ air stripping employs horizontal wells to inject or sparge air into the ground water and vacuum extract VOC`S from vadose zone soils. The horizontal wells provide better access to the subsurface contamination, and the air sparging eliminates the need for surface ground water treatment systems and treats the subsurface in-situ. A full-scale demonstration was conducted at the Savannah River Plant in an area polluted with trichloroethylene and tetrachloroethylene. Results are described.
Climate change is not only dangerous but also expensive. On the other hand, air pollution abatement measures are costly as well. Scientists of the Microeconomics Department investigated how air pollution abatement and cost efficiency can best be combined. (orig.)
Fuzzy theory has been regarded as a very important technique for quality management (QM) of distributed manufacturing system and attracts the attentions of academic and industry; however, there is a lack of a comprehensive literature review and a classification scheme for it. This paper is the first academic literature review of the fuzzy theory applied in quality management of distributed manufacturing system. It involves five most popular databases in this research area and covers more than 20 journals, proposes a classification scheme using clustering analysis method. Sixty-one journal articles were finally selected, reviewed and classified. Each selected article was classified firstly based on four QM dimensions (quality planning, quality control, quality assurance and quality improvem...
I. S. Kirbis, P. Maxwell, M. S. Flear, K. Miller and M. Ibrahim External quality control for immunocytochemistry on cytology samples: a review of UK NEQAS ICC (cytology module) results Objective:- To date, external quality control for immunocytochemistry on cytology samples is provided only by the United Kingdom national external quality assessment service for immunocytochemistry and in situ hybridisation (UK NEQAS ICC & ISH). For the purpose of this study a retrospective analysis of a comprehensive collection of quality-related data regarding immunocytochemistry on cytology samples collected through this service was analysed. Methods:- The quality of immunocytochemical reactions, using on-line collected data, was analysed for the last 23 UK NEQAS ICC cytology module external quality asses...
Purpose - Holding the number of outside directorships constant, this paper aims to test whether executive directors from superior performing firms are subsequently rewarded with better quality outside directorships. Design/methodology/approach - The quality of new outside directorship appointments is modelled using a two-step Heckman selection procedure to control for the probability of acquiring a new outside board seat. Outside directorship quality is estimated using an index formed from series of observable firm-specific characteristics proxying for the following three latent aspects of quality: prestige, reputational risk and monetary rewards. The index aggregates across these three dimensions to produce an overall quality score, with higher scores signifying higher quality directorshi...
Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)
This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor apartment house are ...
This report describes an investigation of the performance of air-augmented waterjet thrusters. The investigation is divided into two parts. Part one describes a study of the injection of large diameter air bubbles to reduce heat transfer between the air and water and, thus, increase the thrust. This study is done analytically by solving the appropriate, governing equations. The results indicate that the approach is very worth-while since thrust can be increased ten percent as compared to air-augmentation with small bubbles. Several practical systems are discussed for injecting large air bubbles. Part two is an experimental investigation of the thrust produced under a wind range of conditions. The results show that a thrust increase of more than 20 percent can be achieved by air-augmentation. Further, the performance improves for larger thrust nozzles.
Using air as a carrier gas is common in humidification?dehumidification desalination processes. A computer program was written using mass and energy balances for modeling the process behavior. The parameters considered in this work were inlet air and fresh water recycle temperatures, inlet air flow rate, saline water and fresh water recycle flow rates, and saline water to air flow ratio. Results of simulation showed that increasing inlet air and fresh water recycle flow rate increases fresh water production. It was also found that heating the inlet air to humidification column or cooling the inlet water to dehumidification column increases the production rate but increasing water to air flow ratio in a humidifier leads to a lower production rate. The predicted effects of the parameters on ...
The aim of this research is to experimentally study the efficiency of a new-design plate collector used to heat air in a new desalination humidification-dehumidification process. In fact, in such processes, the air solar collectors work at unusual experimental parameters (forced convection, elevated air humidity, high solar irradiation). At these stressed experimental conditions, few published works are available in literature. Furthermore, the comparison of the efficiency of collectors running with normal air humidity content (about 10-20 g kg{sup -1}) and air of elevated humidity (20-50 g kg{sup -1}) have not been published to our knowledge. In the present investigation, a new air solar plate collector was designed and developed for its use in a desalination process. Moreover, a characterization of such collector was performed under different experimental ...
In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humility of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows; The air temperature above 8C .deg., the air humidity below 70%, the ...
Huntsville, Alabama Utilities has successfully provided services for over 53 years. However, the quality of service demands from customers are changing every day! Part of this demand is due to updated digital appliances, home and business computers, and automated systems. A quality program was initiated in 1992 as a result of an internal assessment. The Malcolm Baldrige approach was selected which includes seven areas: (1) Leadership; (2) Information and Analysis; (3) Strategic Planning; (4) Human Resource Utilization; (5) Quality Assurance of Products and Services: (6) Quality Results: (7) Customer Satisfaction. Training for and implementation of the Quality program is discussed in detail.
This paper develops a model of nonlinear pricing with competition. The novel element is that each consumer's willingness to pay for quality is private information and is allowed to differ across brands. The consumer's preferences are represented by a multidimensional type containing the marginal value of quality for different products. Buyers with high willingness to pay for quality also display strong preferences for particular brands, and require higher discounts in order to switch away from their favorite product. Therefore, competition is fiercer for buyers with lower tastes for quality, and hence more elastic demands. This is in sharp contrast to earlier models in which competition is fiercer for higher-taste, more valuable buyers. In equilibrium, firms either compete intensively for ...
...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Amazon.com:...The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books Ian Molyneaux,The ...Art of Application Performance Testing : Help for Programmers and Quality Assurance,O'Reilly Media,0596520662,LA9780596520663,Computer Books: General,Application software,Computer software,...com: The Art of Application Performance Testing : Help for Programmers and Quality Assurance (9780596520663): Ian Molyneaux: Books ...
The electrolyte was brought into contact with air and potassium carbonate was measured with various contact time in order to check the defect of carbon dioxide in the air on zinc-air cell. The relationship between potassium carbonate concentration in electrolyte and battery capacity was also studied. The potassium carbonate concentration in the electrolyte. The rate of carbon dioxide absorption was mainly affected by the pore size of hydrophobic membrane. Our study showed that adapting the pore of hydrophobic membrane decreased the loss of cell discharge performance due to the presence of carbon dioxide or water vapor in the atmosphere. 7 refs., 12 figs., 1 tab.
Repeated exposure to cold air reduces the metabolic response to cold air exposure in man. The purpose of this investigation was to measure the change in resting metabolic rate (RMR) with exposure to 22C air and 4C air during a 12 day period. Four women sat in 22C air for 45 min followed by 45 min in 4C air each day for ten days. The authors measured RMR during a 45 min period in 22C air followed by 45 min in 4C air on four days. All subjects began their morning exposures on a Monday within 2 days of the onset of menses completing the study on a Friday, 12 days later. Subjects dressed in a T-shirt, shorts and cotton socks. During 45 min of exposure to warm air, RMR remained steady at 10% of VO{sub 2peak} on Day 1 and 10% on Day 5. RMR during exposure to warm air significantly ...
This paper aims to explore consumer preference for fresh vegetables labelled as organic in combination with health and environment related quality traits. The study decomposes organic farming into its main quality aspects and measures consumers' preference structure for organic, in general, and for specific organic quality traits in particular. By means of stated choice preference modelling, the following hypotheses are tested: consumers prefer health over environment related quality traits; the organic label plays a significant role in consumers' choice for organic products; organic farming is perceived as healthier and more environmentally friendly than conventional farming; purchase intention is mainly driven by health related quality traits; both health and environmental concerns influ...
Managing service quality is vital to retain customer satisfaction and augment revenues for any business organization. Often it is difficult to assess service quality due to lack of quantifiable measures and limited data. In this paper, we present a hybrid approach based on SERVQUAL and fuzzy TOPSIS for evaluating service quality of urban transportation systems. The proposed approach consists of three steps. The first step involves development of a SERVQUAL based questionnaire to collect data for measuring transportation service quality. The participants provide linguistic assessments to rate the service quality criteria and the alternatives. In step 2, the linguistic ratings are combined through fuzzy TOPSIS to generate an overall performance score for each alternative. The alternative wit...