Artery phantoms for intravascular optical coherence tomography: healthy arteries  

UK PubMed Central (United Kingdom)

We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available

2

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.

2000-03-01

3

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

International Nuclear Information System (INIS)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material

2000-03-01

4

Development of calibration facility for radiation protection monitoring instruments  

International Nuclear Information System (INIS)

Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in ...

2008-11-19

5

Performance testing of selected types of electronic personal dosimeters used in Sudan  

International Nuclear Information System (INIS)

Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.

2010-12-01

6

Fast Wire Scanner Calibration  

CERN Document Server

The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to ...

2009-01-01

7

AGARD Flight Test Techniques Series. Volume 1. Calibration ...  

Science.gov (United States)

... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...

1983-09-01

8

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

9

Continuous measurement of blast-furnace coke moisture  

International Nuclear Information System (INIS)

After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).

10

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to registration. Different image registration algorithms were tested using ...

2007-07-01

11

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

British Library Electronic Table of Contents (United Kingdom)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...

2007-01-01

12

Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G  

Energy Technology Data Exchange (ETDEWEB)

Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure ...

1997-12-31

13

Low-range flowmeters for use with vacuum and leak standards  

Energy Technology Data Exchange (ETDEWEB)

Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.

1987-05-01

14

On the accuracy and effectiveness of dose reconstruction for tomotherapy  

International Nuclear Information System (INIS)

Dose reconstruction is a process that re-creates the treatment-time dose deposited in a patient provided there is knowledge of the delivered energy fluence and the patient's anatomy at the time of treatment. A method for reconstructing dose is presented. The process starts with delivery verification, in which the incident energy fluence from a treatment is computed using the exit detector signal and a transfer matrix to convert the detector signal to energy fluence. With the verified energy fluence and a CT image of the patient in the treatment position, the treatment-time dose distribution is computed using any model-based algorithm such as convolution/superposition or Monte Carlo. The accuracy of dose reconstruction and the ability of the process to reveal delivery errors are presented. Regarding accuracy, a reconstructed dose distribution was compared with a measured film distribution for a simulated breast treatment carried out on a thorax ...

2001-04-01

15

Characterization of Adaptive Optics at Keck Observatory  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.

2003-07-24

16

A Human Reliability Analysis of Pre-Accident Human Errors in the Low Power and Shutdown PSA of the KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ANS Low Power /Shutdown (LPSD)PRA Standard, evaluated the LPSD PSA model of the KSNP, Younggwang (YGN) Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the pre-accident human errors in the LPSD PSA model of the KSNP showed that 13 items among 15 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for pre-accident human errors in the LPSD PSA model for the KSNP to improve its quality. We considered potential pre-accident human errors for all manual valves and control/instrumentation equipment of the systems modeled in the KSNP LPSD PSA model except reactor protection system/ engineering safety features actuation system. We reviewed 160 manual valves and 56 control/instrumentation equipment. The number of newly identified ...

2003-04-20

17

Los Alamos second-generation system for passive and active neutron assays of drum-size containers  

International Nuclear Information System (INIS)

We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...

1972-09-17

18

Construction of a homogeneous phantom for radiographic image standardization; Construcao de um fantoma homogeneo para padronizacao de imagens radiograficas  

Energy Technology Data Exchange (ETDEWEB)

The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow ...

1996-12-31

19

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...

2010-08-15

20

Preparation and dosimetry of radiotherapeutic particles for arthropaties; Preparacion y dosimetria de particulas radioterapeuticas para artropatias  

Energy Technology Data Exchange (ETDEWEB)

It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)

1999-07-01

21

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

Energy Technology Data Exchange (ETDEWEB)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection ...

2007-12-15

22

A numerical study of expected accuracy and precision in Calibration-Free Laser-Induced Breakdown Spectroscopy in the assumption of ideal analytical plasma  

International Nuclear Information System (INIS)

Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection ...

2007-12-01

23

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

24

Prediction of transmitted portal dose for in-vivo dosimetry by a superposition-convolution planning system  

International Nuclear Information System (INIS)

Full text: Verification of the dose delivered to a patient during radiotherapy is an important quality assurance procedure, however this is rarely performed due to the extra time involved. Electronic portal images (EPIs) are currently acquired at many centres during radiotherapy treatment for positioning verification. These could be utilised for dose verification provided 1) an accurate prediction of the dose transmitted through the patient to the EPID can be produced for the patients' radiotherapy beams, and, 2) the EPID image can be converted to an accurate measured dose. Ideally, the radiotherapy planning system (RTPS) would be used to produce the predicted dose as part of the planning procedure. The aim of this project is to investigate whether the convolution-superposition model of the Pinnacle RTPS can accurately calculate dose transmitted through a patient and deposited in a phantom at a large source to surface distance. The dose transmitted through a ...

2004-12-01

25

The study of technical error analysis on BMD using DEXA  

International Nuclear Information System (INIS)

This study was conducted to search for the type of technical error in DEXA (dual-energy X-ray absorptiometry) and the effect of error to measurement of BMD. The changes of BMD (g/cm2, T-score) by patients information (Age, Weight, Height, Manopause age) input error and Confirming ROI error were investigated. Using spine phantom, we canned 10 times by age (5, 10), weight (10, 20 kg), height (5, 10 cm), manopause age (5, 10) increase and decrease respectively. Scanning region (L-spine, femur, Forearm) of 10 patients was calculated by changing ROI respectively. Analysis of difference for mean (precision 1%) were carried out. There error of patient information (Age, Weight, Height, Manopause age) was not changed differently. In confirming ROI, the BMD and T-score of L-spine involving T-12 was decreased to 0.063 g/cm2, 0.3 and involving L-5 increased to 0.077 g/cm2, ...

2006-12-01

26

Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis  

Energy Technology Data Exchange (ETDEWEB)

The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was ...

1982-01-01

27

Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)

2001-12-01

28

Quantitative Computed Tomography (QCT) of vertebral spongiosa. Evaluation of a possible method for managment of postmenopausal osteoporosis (PMO)  

International Nuclear Information System (INIS)

A Quantitative Computed Tomography (QCT) method, simplifying the well-known technique proposed by Genant (1982) and applied to a standard third generation whole body CT scanner is described. This technique was applied in the measurement of the trabecular bone which has high sensitivity for metabolic changes. The BMC (Bone Mineral Content) measured in different groups of subjects (healthy postmenopausal patients versus women with postmenopausal osteoporosis) showed a highly significant difference (p<0.001). The precision of repositioning (coefficient of variation 1.8% to 2.3%, obtained in healty male patients) and the good, linear relationship computed from the phantom values, minimize measurement errors. Since this method is quickly applied and involves low-dose radiation-exposure, it could be introduced in the clinical study of metabolic bone diseases.

1987-01-01

29

A compensating method of an imaging plate response to clinical proton beams  

Energy Technology Data Exchange (ETDEWEB)

For charged particle irradiations, the response of an imaging plate (IP) changes around the Bragg peak. Therefore, an appropriate compensation is necessary for the evaluation of dose distribution formed by charged particles such as protons. In this paper, the response of IPs to clinical proton beams is investigated. An experimentally-obtained depth-dose distribution (an ordinary Bragg curve) by a silicon semiconductor detector (SSD) is employed to evaluate the compensation factors as a function of proton penetrating depth, i.e. residual range. A typical dose distribution in a water phantom formed by an L-shaped bolus is measured by IPs and corrected by using the information of those compensation factors; the residual proton range is successfully calculated by the pencil beam algorithm at an arbitrary point. The results show a good agreement with the measurements by the SSD within the rms error of 3.0%.

2002-04-01

30

Grid-Search Location Methods for Ground-Truth Collection From Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...

2005-05-13

31

Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry  

International Nuclear Information System (INIS)

Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of ...

1977-12-09

32

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed ...

2010-10-01

33

Radiometric measurement of temperature distributions in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

An engineering tool incorporating a scanning infrared radiometer, an image digitizer, a microcomputer, and the software to drive the system was developed to allow remote mapping of the temperature distribution in solar cavity receivers. Using enclosure analysis, the infrared image processing program extracts the irradiance map from the radiosity map of the cavity to yield an emissive power map. Using the calibration curve of the radiometer and the emissivity of the surface of the cavity, the emissive power map is transformed into a temperature map. The system was tested by comparing its calculated temperatures to temperatures measured by thermocouples at several locations on the surfaces of heated model cavity receivers. The average relative error for the cavities ranged from 4.6%--34.9%, with the relative error on the base usually less than half that on the wall. Some work was also carried out to compensate the detected ...

1989-03-01

34

A gradient feature weighted Minimax algorithm for registration of multiple portal images to 3DCT volumes in prostate radiotherapy  

International Nuclear Information System (INIS)

Purpose: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. Methods and Materials: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. Results: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax ...

2006-06-01

35

Type Ia supernova science 2010-2020  

CERN Document Server

In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0

2009-01-01

36

Method of calibration to correct for cloud-induced wavelength shifts in the Aura satellite's Ozone Monitoring Instrument  

Science.gov (United States)

The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is ...

2006-05-01

37

A proposed methodology for computational fluid dynamics code verification, calibration, and validation  

Energy Technology Data Exchange (ETDEWEB)

Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...

1995-07-01

38

Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

39

Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

40

Double peak effect in microdosimetric proportional counters and its interpretation  

Energy Technology Data Exchange (ETDEWEB)

In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.

1989-01-01

41

Analysis on Correlation between AE Parameters and Stress Intensity Factor using Principal Component Regression and Artificial Neural Network  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model

2001-02-15

42

Monte Carlo evaluation of the AAA treatment planning algorithm in a heterogeneous multilayer phantom and IMRT clinical treatments for an Elekta SL25 linear accelerator  

International Nuclear Information System (INIS)

The Anisotropic Analytical Algorithm (AAA) is a new pencil beam convolution/superposition algorithm proposed by Varian for photon dose calculations. The configuration of AAA depends on linear accelerator design and specifications. The purpose of this study was to investigate the accuracy of AAA for an Elekta SL25 linear accelerator for small fields and intensity modulated radiation therapy (IMRT) treatments in inhomogeneous media. The accuracy of AAA was evaluated in two studies. First, AAA was compared both with Monte Carlo (MC) and the measurements in an inhomogeneous phantom simulating lung equivalent tissues and bone ribs. The algorithm was tested under lateral electronic disequilibrium conditions, using small fields (2x2 cm"2). Good agreement was generally achieved for depth dose and profiles, with deviations generally below 3% in lung inhomogeneities and below 5% at interfaces. However, the effects of attenuation and scattering close to the bone ribs were not ...

2007-05-01

43

Accuracy of calculations for stereotactic radiotherapy of the lung. Comparison of dose calculation algorithms  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the accuracy of dose calculations by three algorithms. Depth dose, OPF (Output Factor) and dose profiles were measured in a heterogeneous phantom. These values were also calculated by three algorithms of the Batho power law (BPL), Equivalent-Tissue Air Ratio (ETAR) and Convolution superposition (CS). The data were obtained for 4, 6 and 10 MV photon beams with a linear accelerator (Varian 21EX). Field size ranged from 3 x 3 cm"2 to 10 x 10 cm"2. Dose profiles of beam penumbra were also measured by a 0.125 ml ionization chamber at the point of 8, 13 and 18 cm from the surface of the phantom at intervals of 1 mm. Differences between measured and calculated depth doses were within 2% in BPL and CS, but depth doses were overestimated in ETAR. OPFs were also overestimated with the error of more than 4% in ETAR. Absorbed dose calculated by CS were in agreement with the values measured by ...

2004-12-01

44

The validity of the density scaling method in primary electron transport for photon and electron beams  

International Nuclear Information System (INIS)

In the convolution/superposition method of photon beam dose calculations, inhomogeneities are usually handled by using some form of scaling involving the relative electron densities of the inhomogeneities. In this paper the accuracy of density scaling as applied to primary electrons generated in photon interactions is examined. Monte Carlo calculations are compared with density scaling calculations for air and cork slab inhomogeneities. For individual primary photon kernels as well as for photon interactions restricted to a thin layer, the results can differ significantly, by up to 50%, between the two calculations. However, for realistic photon beams where interactions occur throughout the whole irradiated volume, the discrepancies are much less severe. The discrepancies for the kernel calculation are attributed to the scattering characteristics of the electrons and the consequent oversimplified modeling used in the density scaling method. A technique called the kernel integration ...

45

A comparison study for dose calculation in radiation therapy: pencil beam Kernel based vs. Monte Carlo simulation vs. measurements  

International Nuclear Information System (INIS)

Accurate dose calculation in radiation treatment planning is most important for successful treatment. Since human body is composed of various materials and not an ideal shape, it is not easy to calculate the accurate effective dose in the patients. Many methods have been proposed to solve inhomogeneity and surface contour problems. Monte Carlo simulations are regarded as the most accurate method, but it is not appropriate for routine planning because it takes so much time. Pencil beam kernel based convolution/superposition methods were also proposed to correct those effects. Nowadays, many commercial treatment planning systems have adopted this algorithm as a dose calculation engine. The purpose of this study is to verify the accuracy of the dose calculated from pencil beam kernel based treatment planning system comparing to Monte Carlo simulations and measurements especially in inhomogeneous region. Home-made inhomogeneous phantom, Helax-TMS ver. 6.0 and Monte ...

2002-10-20

46

Importance of anthropomorphic phantoms in nuclear medicine  

International Nuclear Information System (INIS)

... Brasileira de Biociencias Nucleares (SBBN), Recife, PE (Brazil) INIS-BR--9282

2010-10-27

47

Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...

1988-08-01

48

Dead-time calibrator  

International Nuclear Information System (INIS)

... interval analyzers counting techniques discriminators electronic circuits

51

Monte Carlo simulation and dosimetric verification of radiotherapy beam modifiers  

International Nuclear Information System (INIS)

Monte Carlo simulation of beam modifiers such as physical wedges and compensating filters has been performed with a rectilinear voxel geometry module. A modified version of the EGS4/DOSXYZ code has been developed for this purpose. The new implementations have been validated against the BEAM Monte Carlo code using its standard component modules (CMs) in several geometrical conditions. No significant disagreements were found within the statistical errors of 0.5% for photons and 2% for electrons. The clinical applicability and flexibility of the new version of the code has been assessed through an extensive verification versus dosimetric data. Both Varian multi-leaf collimator (MLC) wedges and standard wedges have been simulated and compared against experiments for 6 MV photon beams and different field sizes. Good agreement was found between calculated and measured depth doses and lateral dose profiles along both wedged and unwedged directions for different depths and ...

2001-11-01

52

Evaluation of the 1Shot Phantom dedicated to the mammography system using FCR  

International Nuclear Information System (INIS)

Currently daily quality control (QC) tests for mammography systems are generally evaluated by using visual analysis phantoms, which of course means subjective measurement. In our study, however, we evaluated a novel digital phantom, the 1Shot Phantom M plus (1Shot Phantom), together with automatic analysis software dedicated for mammography systems using Fuji computed radiography (FCR). The digital phantom enables objective evaluation by providing for actual physical measurement rather than subjective visual assessment. We measured contrast to noise ratio (CNR), image receptor homogeneity, missed tissue at chest wall side, modulation transfer function (MTF), and geometric distortion utilizing the 1Shot Phantom. We then compared the values obtained using the 1Shot Phantom with values obtained from the European guidelines and International ...

2009-07-01

53

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, ...

2007-03-15

54

Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels  

International Nuclear Information System (INIS)

Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume ...

2005-02-21

55

Sampling and analytical methodologies for energy dispersive X-ray fluorescence analysis of airborne particulate matter  

International Nuclear Information System (INIS)

The present document represents an attempt to summarize the most important features of the different forms of ED-XFR as applied to the analysis of airborne particulate matter. It is intended to serve as a set of guidelines for use by participants in the IAEA's own programmes, and other scientists, who are not yet fully experienced in the application of ED-XRF to airborne particulate samples, and who wish either to make a start on using this technique or to improve their existing procedures. The methodologies for sampling described in this document are of rather general applicability. Emphasis is also placed on the sources of errors affecting the sampling of airborne particulate matter. The analytical part of the document describes the different forms of ED-XRF and their potential applications. Spectrum evaluation, a key step in X-ray spectrometry, is covered in depth, including discussion on several calibration and peak fitting techniques and ...

1986-06-25

56

FFTF fission gas monitor computer system  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated ...

57

Calibrating Emission Lines as Quasar Bolometers  

CERN Document Server

Historically, emission lines have been considered a valuable tool for estimating the bolometric thermal luminosity of the accretion flow in AGN, $L_{bol}$. We study the reliability of this method by comparing line strengths to the optical/UV continuum luminosity of SDSS DR7 radio quiet quasars with $0.4errors of the formulae that are fitted to the data. Our new estimators are shown to be more accurate than archival line strength estimations in the literature. It is demonstrated that the broad lines are superior estimators of the continuum luminosity (and $L_{bol}$) with $H\\beta$ being the most reliable. The fidelity of the each of the estimators is determined in the context of the SDSS DR7 radio loud quasars as an illustrative application of our results. In ...

2011-01-01

58

Assay of the uranium and plutonium content in process residues and wastes using the correction for sample self attenuation in segmented gamma scanning system  

International Nuclear Information System (INIS)

A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium content in process residues and wastes is 5% with 68.3% of ...

1998-09-01

59

Hydrogen storage in nano-structured carbon materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...

2005-07-01

60

Hydrogen storage in nano-structured carbon materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides imposes heavy devices. A ...

2005-07-01

61

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

62

Uncertainty analysis of high altitude aircraft air mass zero solar cell calibration  

Energy Technology Data Exchange (ETDEWEB)

Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.

1997-12-31

63

Total suspended matter observation in the Pearl River estuary from in situ and MERIS data.  

Science.gov (United States)

Based on the cruise data collected in the Pearl River estuary (PRE) in May 2008, an empirical two-band model by using the ratio of R (rs) at 629 and 671 nm was established to retrieve total suspended matter (TSM) concentration with the determination coefficient (R(2)) of 0.854, mean relative error (MRE) of 7.483%, and root-mean-square error (RMSE) of 1.295 mg L(?-?1). To match with medium resolution imaging spectrometer (MERIS) bands, in situ remote sensing reflectance was re-sampled to the bandwidth of 10 nm. The relationship between TSM and re-sampled R (rs) at 620 nm (MERIS band 6) and 665 nm (MERIS band 7) are obtained (R(2) = 0.748, RMSE = 1.697 mg L(?-?1), MRE = 8.785%, n = 13). Additionally, to map the spatial distribution of TSM in the PRE, MERIS level_1B data were calibrated using a multiple linear regression model based on in situ R (rs). Another dataset collected in the PRE in January 2004 was used to validate ...

2010-09-01

64

Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples  

UK PubMed Central (United Kingdom)

BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available

65

Calibration of the solar UV radiometers in Finland  

Energy Technology Data Exchange (ETDEWEB)

In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included

1996-12-31

66

Outpatient Prescribing Errors and the Impact of Computerized Prescribing  

UK PubMed Central (United Kingdom)

BackgroundMedication errors are common among inpatients and many are preventable with computerized prescribing. Relatively little is known about outpatient prescribing errors or...Full Text Available

2005-09-01

68

SAMS Research and Development  

Science.gov (United States)

... resolution video. RESULTS Statistics describing the typical inertial navigation error growth were collected. Typical errors ...

2008-08-06

69

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of ...

2003-07-01

70

Estimation of half-life values of actinide radionuclides  

International Nuclear Information System (INIS)

... actinides americium 241 americium 242 americium 243 calibration standards

1986-04-15

73

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...

2001-03-01

74

Syringe calibration factors and volume correction factors for the NPL secondary standard radionuclide calibrator  

CERN Document Server

The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.

2002-01-01

75

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The image quality of direct digital radiography system is improved as ...

2005-10-01

76

Phase-space analysis of interacting phantom cosmology  

CERN Document Server

We perform a detailed phase-space analysis of various phantom cosmological models, where the dark energy sector interacts with the dark matter one. We examine whether there exist late-time scaling attractors, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. We find that all the examined models, although accepting stable late-time accelerated solutions, cannot alleviate the coincidence problem, unless one imposes a form of fine-tuning in the model parameters. It seems that interacting phantom cosmology cannot fulfill the basic requirement that led to its construction.

2008-01-01

77

Phantom dark energy with varying-mass dark matter particles: acceleration and cosmic coincidence problem  

CERN Document Server

We investigate several varying-mass dark-matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.

2009-01-01

78

Morphine versus Mexiletine for Treatment of Postamputation Pain  

UK PubMed Central (United Kingdom)

BackgroundStump and phantom pains are debilitating sequelae of amputations that are often resistant to treatment. The efficacy of pharmacologic therapies, including...Full Text Available

2008-08-01

79

Comparing dose calculation algorithms for an orthovoltage beam in a bone phantom  

International Nuclear Information System (INIS)

The aim of this work was to compare dose calculation algorithm results at orthovoltage energies for a phantom composed of a bone slab in water. The calculation methods investigated were: no correction, ETAR, Batho, convolution/superposition and Monte Carlo. All algorithms calculated depth dose curves in a water phantom within 4% of experiment. However in the bone phantom, differences of over 40% between the No Correction / ETAR / Batho / Convolution and Monte Carlo results in the 1 cm thick bone slab were observed. These differences are predominantly because the algorithms do not account for the differing atomic number of the bone compared to water The increased dose to bone and the tissue adjacent to the bone interface should be considered when treating with orthovoltage photons. Copyright (1998) Australasian Physical and Engineering Sciences in Medicine

1998-09-01

80

Chronic Pain Associated with Upper-Limb Loss  

UK PubMed Central (United Kingdom)

ObjectiveTo describe the prevalence, intensity, and functional impact of the following types of pain associated with upper-limb loss: phantom limb, residual limb,...Full Text Available

2009-09-01

81

Numerical modelling of surface hydrology and near-surface hydrogeology at Forsmark. Site descriptive modelling SDM. Site Forsmark  

Energy Technology Data Exchange (ETDEWEB)

SKB is currently performing site investigations at two potential sites for a final repository for spent nuclear fuel. This report presents results of water flow and solute transport modelling of the Forsmark site. The modelling reported in this document focused on the near-surface groundwater, i.e. groundwater in Quaternary deposits and shallow rock, and surface water systems, and was performed using the MIKE SHE tool. The most recent site data used in the modelling were delivered in the Forsmark 2.3 dataset, which had its 'data freeze' on March 31, 2007. The present modelling is performed in support of the final version of the Forsmark site description that is produced during the site investigation phase. In this work, the hydrological modelling system MIKE SHE has been used to describe near-surface groundwater flow and the contact between groundwater and surface water at the Forsmark site. The surface water system at Forsmark is described with the one-dimensional ...

2008-09-15

82

Reduction of statistic error in Mihalczo subcriticality measurement  

Energy Technology Data Exchange (ETDEWEB)

The theoretical formula for the statistical error estimation in Mihalczo method was derived, and the dependence of the error were investigated on the facility to be measured and on the parameter in the data analysis. The formula was derived based on the reactor noise theory and the error theory for the frequency analysis, and found that the error depends on such parameters as the prompt neutron decay constant, detector efficiencies, and the frequency bandwidth. Statistical errors estimated with the formula was compared with experimental values and verified to be reasonable. Through parameter surveys, it is found that there is an optimum combination of the parameters to reduce the magnitude of the errors. In the experiment performed in DCA subcriticality measurement facility, it is estimated experimentally that the measurement requires 20 minutes to obtain the ...

1998-08-01

83

A deterministic partial differential equation model for dose calculation in electron radiotherapy  

International Nuclear Information System (INIS)

High-energy ionizing radiation is a prominent modality for the treatment of many cancers. The approaches to electron dose calculation can be categorized into semi-empirical models (e.g. Fermi-Eyges, convolution-superposition) and probabilistic methods (e.g. Monte Carlo). A third approach to dose calculation has only recently attracted attention in the medical physics community. This approach is based on the deterministic kinetic equations of radiative transfer. We derive a macroscopic partial differential equation model for electron transport in tissue. This model involves an angular closure in the phase space. It is exact for the free streaming and the isotropic regime. We solve it numerically by a newly developed HLLC scheme based on Berthon et al (2007 J. Sci. Comput. 31 347-89) that exactly preserves the key properties of the analytical solution on the discrete level. We discuss several test cases taken from the medical physics literature. A test case with an academic ...

2010-07-07

84

"Advanced" data reduction for the AMBER instrument  

CERN Document Server

The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...

2008-01-01

85

Users' guide on socket heat fusion joining of polyethylene gas pipes. Volume 1. Topical report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion ...

1991-03-01

86

Technical reference on socket heat fusion joining of polyethylene gas pipes. Volume 2. Topical Report, September 1989-September 1990  

Energy Technology Data Exchange (ETDEWEB)

The integrity of a pipeline system is determined by its weakest links which may be the joints. Heat fusion is the most common method for joining gas distribution polyethylene (PE) piping. There are procedural, thermal, and mechanical aspects of making fusion joints. Acceptable procedural aspects, such as heater calibration and cleanliness, can be assured by rigorous training and certification of the operators. Thermal and mechanical aspects consist of specifying joining conditions such as the heater temperature, heating time, and joining pressure. In the absence of procedural errors, the strength of a fusion joint should depend on the pipe material, pipe dimensions, and the thermal and mechanical joining conditions. Socket heat fusion was studied both experimentally and analytically to determine how the strength of the joint varied with the conditions under which it was made. The standard tensile impact test was modified to test socket fusion ...

1991-03-01

87

Cosmic Evolution of Black Holes And Spheroids. 1, the M(BH)-Sigma Relation at Z=0.36  

Energy Technology Data Exchange (ETDEWEB)

We test the evolution of the correlation between black hole mass and bulge velocity dispersion (M{sub BH} - {sigma}), using a carefully selected sample of 14 Seyfert 1 galaxies at z = 0.36 {+-} 0.01. We measure velocity dispersion from stellar absorption lines around Mgb (5175 {angstrom}) and Fe (5270 {angstrom}) using high S/N Keck spectra, and estimate black hole mass from the H{beta} line width and the optical luminosity at 5100 {angstrom}, based on the empirically calibrated photo-ionization method. We find a significant offset from the local relation, in the sense that velocity dispersions were smaller for given black hole masses at z = 0.36 than locally. We investigate various sources of systematic uncertainties and find that those cannot account for the observed offset. The measured offset is {Delta} log M{sub BH} = 0.62 {+-} 0.10 {+-} 0.25, i.e. {Delta} log {sigma} = 0.15 {+-} 0.03 {+-} 0.06, where the error bars include a random ...

2006-04-17

88

Considering uncertainties in the reservoir interpretation of geophysical data. Application to segmentation; Prise en compte des incertitudes dans l'interpretation reservoir des donnees geophysiques. Application a la segmentation  

Energy Technology Data Exchange (ETDEWEB)

Qualitative interpretation of data of different nature and sources, based on segmentation techniques such as discriminant analysis, is useful to characterize and monitor hydrocarbon reservoirs. In order to make this interpretation more reliable, it is necessary to characterize uncertainties attached to data and then, to propagate them in the interpretation work-flow. In this thesis, uncertainties are represented by intervals, because usually, little is known about input data errors. The uncertainty characterization issue is dealt with specifically for each case study. The uncertainty propagation issue is treated by a new technique, based on interval analysis, which consists in extending to intervals various popular approaches (non parametric, quadratic and linear) to discriminant analysis: Firstly, a learning phase allows calibrating an imprecise classifying model on the basis of pre-interpreted data. If the quality of this model is good ...

2001-10-01

89

A survey of community members' perceptions of medical errors in Oman  

UK PubMed Central (United Kingdom)

BackgroundErrors have been the concern of providers and consumers of health care services. However, consumers' perception of medical errors in developing countries is rarely explored....Full Text Available

90

Some sources of error in property indices for coke-oven charge  

Science.gov (United States)

The author points out that errors in certain measurements are preventing improvements in coke: thermocouples (errors caused by the thermocouple installation and variations in the temperature of the cold junctions); dilatometers (errors caused by size of heating block and differences in starting temperature led to differences between two instruments); errors in measuring the bulk density of the coking charge. The elimination of these sources of error in determinations of the technological and physical properties of coke oven charge should assist in the study of other problems which are delaying improvements in blast furnace coke production.

1981-01-01

91

HPA - Radon Calibration Facilities  

Wastenet

... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...

92

Design Calibration and Field Use of a Stomatal Diffusion Porometer  

UK PubMed Central (United Kingdom)

Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available

1969-06-01

93

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Function of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.

2009-06-17

94

iII1TEImETFlIES - NASA Technical Report Server (NTRS)  

Science.gov (United States)

The various sources of inertial navigation error are discussed in Section 2.2. It is the nature of inertial navigation errors ...

95

Utilization of consistency metrics for error analysis in deformable image registration  

UK PubMed Central (United Kingdom)

PurposeTo investigate the utility of consistency metrics, such as inverse consistency, in contour based deformable registration error analysis.Full Text Available

2009-09-21

96

Tightly Integrating Optical And Inertial Sensors For Navigation ...  

Science.gov (United States)

... 13 2.4 Inertial Navigation Error Model . . . . . ... sources such as electrical noise, thermal noise, etc. 2.4 Inertial Navigation Error Model ...

2008-03-01

97

Gravity Gradiometer Survey and Real Time Techniques for ...  

Science.gov (United States)

... 4 II. INERTIAL NAVIGATION ERROR EQUATIONS ..... 5 ... 4- Page 20. Chapter II INERTIAL NAVIGATION ERROR EQUATIONS ...

1981-12-01

98

Fusion of Imaging and Inertial Sensors for Navigation  

Science.gov (United States)

... 2.5.6 Development of Observation Equations . . . . . 25 2.6 Inertial Navigation Error Model . . . . . ... 2 , as expected. 2.6 Inertial Navigation Error Model ...

2006-09-01

99

Error Analysis Strapdown Inertial Navigation Using ...  

Science.gov (United States)

... Abstract : The purpose of this paper is to introduce strapdown inertial navigation error equations based on a quaternion relation between body-fixed ...

1986-06-01

101

A Hybrid Integrity Solution for Precision Landing and ...  

Science.gov (United States)

... HAL and VAL limits with the specified PMD of 10-7, the GPS range-rate error must be monitored to assure that the inertial navigation error is not ...

2004-04-01

102
103

Development and Calibration of Two and Four Wire Water ...  

Science.gov (United States)

... measurement. Power spectral density measurements are made by the dynamic signal analyzer for each channel. A cross power ...

1992-12-01

104

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

105

Pulsed Radiofrequency Ablation for Residual and Phantom Limb Pain: A Case Series  

British Library Electronic Table of Contents (United Kingdom)

Abstract Residual limb pain (RLP) and phantom limb pain (PLP) can be debilitating and can prevent functional gains following amputation. High correlations have been reported between RLP and the stump neuromas following amputation. Many treatment methods including physical therapy, medications, and interventions, have been used with limited success. Pulsed radiofrequency ablation (PRFA) has shown promise in treating neuropathic pain because of the inhibition of evoked synaptic activity. We present 4 amputees who were treated with PRFA after failing conservative management for their RLP and PLP. All 4 patients underwent PRFA and demonstrated at least 80% relief of RLP for over 6 months. One patient reported a complete resolution of phantom sensation while another patient had significantly de...

2010-01-01

106

Monte Carlo simulations incorporating Mie calculations of light transport in tissue phantoms: Examination of photon sampling volumes for endoscopically compatible fiber optic probes  

Energy Technology Data Exchange (ETDEWEB)

Details of the interaction of photons with tissue phantoms are elucidated using Monte Carlo simulations. In particular, photon sampling volumes and photon pathlengths are determined for a variety of scattering and absorption parameters. The Monte Carlo simulations are specifically designed to model light delivery and collection geometries relevant to clinical applications of optical biopsy techniques. The Monte Carlo simulations assume that light is delivered and collected by two, nearly-adjacent optical fibers and take into account the numerical aperture of the fibers as well as reflectance and refraction at interfaces between different media. To determine the validity of the Monte Carlo simulations for modeling the interactions between the photons and the tissue phantom in these geometries, the simulations were compared to measurements of aqueous suspensions of polystyrene microspheres in the wavelength range 450-750 nm.

1996-04-01

107

Dose enhancement in bone in electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

1984-05-01

108

Dose enhancement in bone in electron beam therapy  

International Nuclear Information System (INIS)

This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeV electron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mev electrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is possible in those clinical situations where high doses of electrons are used for therapy.

109

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization ...

2003-04-08

111

Neural classifier construction using regularization, pruning and test error estimation.  

Science.gov (United States)

In this paper we propose a method for construction of feed-forward neural classifiers based on regularization and adaptive architectures. Using a penalized maximum likelihood scheme, we derive a modified form of the entropic error measure and an algebraic estimate of the test error. In conjunction with optimal brain damage pruning, a test error estimate is used to select the network architecture. The scheme is evaluated on four classification problems. PMID:12662736

1998-12-01

112

NASA Technical Reports Server - Magnetic forming coil design and ...  

Science.gov (United States)

Site Error There's a problem with your browser or settings. ...

114

 

Wastenet

com/Descartes-Error-Emotion-Reason-Human/dp/014303622X/ref=cm_lmf_img_12_rdssss0\\

115

PHARMACOLOGICAL TREATMENTS FOR TINNITUS: NEW AND OLD  

UK PubMed Central (United Kingdom)

Subjective tinnitus, the phantom ringing or buzzing sensation that occurs in the absence of sound, affects 12–14% of adults; in some cases the tinnitus is so severe or disabling that...Full Text Available

2009-01-01

116

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

117

Intelligent Motion and Interaction Within Virtual Environments  

Science.gov (United States)

Typical aircraft types supported include F4-Phantom, Tornado, MiG-29 ...... attempt to develop a theoretical explanation for learning phenomena [16]. ..... perspective, a primary reason for this is that an exponential curve approximates ...

118

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

Energy Technology Data Exchange (ETDEWEB)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom ...

1995-08-01

119

Computed radiography in X-ray examination of stomach. Evaluation by phantom experiments and clinical studies  

International Nuclear Information System (INIS)

The usefulness and clinical applicability of computed radiography(FCR) in X-ray examination of the stomach were evaluated in comparison with film-screen (FS) radiography by both phantom experiments and clinical studies. Receiver operating characteristic (ROC) curve analysis consisting of 25 normal and 25 artificially created simulated lesions on an orginally created Styrofoam phantom showed no difference in lesion detectability between FCR and FS radiography. Both were also equal in evaluation of the internal structure and margin of the 25 lesions by visual ranking. ROC curve analysis of clinical cases was performed in 30 cases, 20 normal and 10 abnormal, while evaluation by visual ranking was performed on 18 lesions. There was no significant difference between FCR and FS radiography either with ROC curve analysis or visual ranking, although the variations were somewhat greater in the clinical cases than in the phantom ...

1995-01-01

120

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: comparison of calculated and measured 10-MV X-ray doses in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.

2011-01-01

121

Challenges and Solutions to Producing a Useful High Resolution Soil Moisture Product  

Science.gov (United States)

Information about surface soil moisture conditions is of critical importance to real-world applications such as agricultural production, water resource management, flood prediction, fire prediction, water supply, military mobility, etc.. Near-surface soil moisture is currently available from non-ideal sensor configuration observations, and two missions targeted at measuring near-surface soil moisture with ideal sensor configuration are expected before the end of the decade (the European Space Agency (ESA), Soil Moisture and Ocean Salinity (SMOS) mission, and the National Aeronautics and Space Administration (NASA), Hydrospheric states "Hydros" mission). Though remote sensing can make spatially comprehensive measurements of surface soil moisture, it cannot provide information on the entire land surface hydrologic system, and the measurements represent only a snap shot in time. Alternatively, land surface hydrology process models may be used to predict the temporal and spatial ...

2005-05-01

122

C-106 tank process ventilation test  

Energy Technology Data Exchange (ETDEWEB)

Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to the tank and connecting temporary ducting and an inlet air filter and housing to the recirculation system. This configuration would eventually become the possible ...

1998-07-20

123

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are ...

1999-07-01

124

Signal simulator for the calibration of eddy current probes  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.

1994-01-01

125

Calibration system for spot welding robots in offline-teaching; Offline teaching ni okeru spot yosetsu robot yo calibration system  

Energy Technology Data Exchange (ETDEWEB)

Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)

1999-04-01

126

Tests of the ONERA Calibration Models in Three Transonic ...  

Science.gov (United States)

... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...

1976-11-01

127

Stability of modulation transfer function calibration of surface profilometers using binary pseudo-random gratings and arrays with nonideal groove shapes  

Energy Technology Data Exchange (ETDEWEB)

The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.

2010-03-31

128

Satellite Calibration Data. Annual Data Report - 1977  

Science.gov (United States)

... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...

1979-08-01

129

Salt Lake City shows hot and cold spots - NASA ... - Science@NASA  

Science.gov (United States)

Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...

130

LBA Calibrator Survey - NASA  

Science.gov (United States)

Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...

131

Ionization-chamber-dependent factors for calibration of megavoltage X-ray and electron beam therapy machines  

International Nuclear Information System (INIS)

When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that ...

132

DMSP Special Sensor Microwave/Imager Calibration ...  

Science.gov (United States)

... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...

2011-05-14

133

Comparison of methods to determine accurate dose calibrator activity measurements  

UK PubMed Central (United Kingdom)

BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available

134

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

135

Calibrating Cosmological Chronometers: White Dwarf Masses ...  

Science.gov (United States)

... The second scenario is limited by the age of our Galaxy such that the lowest-mass WD that could be formed via single star evolution is ~0.47 M ...

2011-05-14

136

BIG BEAR SOLAR OBSERVATORY - NASA Technical Report Server (NTRS)  

Science.gov (United States)

replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...

137

Practical statistics for particle physicists  

CERN Document Server

Learning to love the errror matrix lecture : Learning to love the errror matrix Introductory remarks. Conditional probability. Statistical and systematic errors. Combining results Binomial, Poisson and 1-D Gaussian 2-D Gaussian and the error matrix. Understanding the covariance. Using the error matrix. Estimating the error matrix. Combining correlated measurements Parameter determination by likelihood Do's and don'ts lecture : Parameter determination by likelihood : Do's and don'ts Introduction to likelihood. Error estimate. Simple examples: (1) Breit Wigner (2) Lifetime Binned and unbinned likelihood Several parameters Extended maximum likelihood. Common misapprehensions: Normalisation delta(lnL) = 1/2 rule and coverage Integrating the likelihood Unbinned L_max as goodness of fit Punzi effect Chi-squared and hypothesis testing lecture : Chi-squared and hypothesis testing Basic ...

2006-01-01

138

Perceived association between diagnostic and non-diagnostic cues of women's sexual interest: General Recognition Theory predictors of risk for sexual coercion  

UK PubMed Central (United Kingdom)

Young men's errors in sexual perception have been linked to sexual coercion. The current investigation sought to explicate the perceptual and decisional sources of these social perception errors,...Full Text Available

2010-01-01

139

Impact of Basic Computerized Prescribing on Outpatient Medication Errors and Adverse Drug Events  

UK PubMed Central (United Kingdom)

Few data exist about the impact of computerized prescribing systems on outpatient medication errors (MEs) and adverse drug events (ADEs). We compared the rates of MEs and ADEs in handwritten sites versus...Full Text Available

2002-11-01

140

Scale-dependent errors in the estimation of land-cover proportions. Implications for global land-cover datasets  

Energy Technology Data Exchange (ETDEWEB)

Aggregation of fine-resolution land-cover maps to coarser scales indicates that estimates of the proportions of land-cover types vary as a function of spatial resolution. The magnitude of these proportional errors in a forested area in northern California increase significantly as resolution exceeds a 90-m threshold. These errors could pose difficulties for the use of land-cover products generated from coarse-resolution sensors such as the NOAA-AVHRR and the MODIS sensor planned for the EOS program. The magnitude of the errors appears to be a function of the spatial resolution of the map, the original size of the land-cover classes, and the spatial patterns of the classes.

1994-05-01

142

A Kalman Filter Clock Algorithm for Use in the Presence of ...  

Science.gov (United States)

... Following the application of the error covariance update equation, we apply the following operation to the parameter covariance matrix P+: ...

2004-09-01

143

//?- ,/7--,-:L..  

Science.gov (United States)

down inertial navigation systemshavebeenreported. Shibata (1986)describesthe strapdown inertial navigation error equations basedon a quaternion relationship ...

144

"2"0"3Pb yields while irradiating thallium with protons and deuterons  

International Nuclear Information System (INIS)

... data deuteron beams energy dependence errors gamma radiation lead 203

145

Development of a geometrically accurate imaging protocol at 3 Tesla MRI for stereotactic radiosurgery treatment planning  

International Nuclear Information System (INIS)

The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic ...

2010-11-21

146

Numerical error analysis of direct integration method  

Energy Technology Data Exchange (ETDEWEB)

Numerical errors of PALLAS calculation due to spatial mesh sizes are examined for a typical deep penetration shielding problem of isotropic incident fission neutrons penetrating a 200-cm-thick water slab. The exponential approximation for the source spatial distribution to solve the transport equation based on the direct integration method is verified to be effective for radiation transport in attenuating medium, while the linear approximation employed in the old PALLAS code is found to produce large errors for calculations with large mesh sizes.

1986-01-01

147

Human error and experienced feedback during refuelling overhauling of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The authors describe the various human error encountered during Daya bay refueling overhaul, and the subsequent root cause evaluation and protective measure. Authors consider transparency is the key in reducing human error and event recurrence. Additional y, event transparency will enhance the effectiveness if experience feedback and reduce event consequence

2000-10-01

148

A Human Reliability Analysis of Post- Accident Human Errors in the Low Power and Shutdown PSA of KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ANS low power and shutdown (LPSD) probabilistic risk assessment (PRA) Standard, evaluated the LPSD PSA model of the KSNP, Yonggwang Units 5 and 6, and identified the items to be improved. The evaluation results of human reliability analysis (HRA) of the post-accident human errors in the LPSD PSA model for the KSNP showed that 10 items among 19 items of supporting requirements for those in the ANS PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for post-accident human errors in the LPSD PSA model for the KSNP. Following tasks are the improvements in the HRA of post-accident human errors of the LPSD PSA model for the KSNP compared with the previous one: Interviews with operators in the interpretation of the procedure, modeling of operator actions, and the quantification results of human errors, site visit. Applications ...

2010-05-01

149

Industrial experience with an intelligent AC/DC standard  

Energy Technology Data Exchange (ETDEWEB)

AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.

1989-04-01

150

Gamma spectrometry calibrations with natural radioactive materials  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).

1996-02-01

151

Gamma spectrometry calibrations with natural radioactive materials  

International Nuclear Information System (INIS)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).

152

Determination of efficiency curves of germanium detectors using natural radioactive materials  

International Nuclear Information System (INIS)

Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).

153

Study of spatial resolution in three-dimensional rotational angiography  

International Nuclear Information System (INIS)

In interventional radiology (IVR) of cerebral aneurysms, it is important to understand the form and physical relationships between the cerebral aneurysm and the surrounding vessels. However, because the vessels in the head area are highly complex, it can be difficult to comprehend the structure using conventional angiography. Therefore, three-dimensional rotational angiography (3D-RA) has been used in recent years. This article discusses studies of the spatial resolution of 3D-RA. We reconstructed 3D-RA of an acrylic slit phantom (slit widths: 0.5, 0.75, 1.0, 1.5 mm) and examined spatial resolution by visual evaluation and profile curves. When the slit phantom was arranged to avoid the effect of beam hardening, the spatial resolution of 3D-RA was found to be as high as 0.75 mm. When the slit phantom was placed orthogonal to the rotational axis of the C-arm, the spatial resolution of 3D-RA was decreased because of the cone ...

2006-03-01

154

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and inexpensive ultra-high resolution imaging system on 5C1 beamline was successfully implemented. The authors were able to acquire ...

2001-01-01

155

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si[sup ...

1992-01-01

156

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si"6Li). ...

1991-10-01

157

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable ...

2011-03-14

158

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range  

Energy Technology Data Exchange (ETDEWEB)

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test ...

2010-07-26

159

TOA/FOA geolocation error analysis.  

Energy Technology Data Exchange (ETDEWEB)

This paper describes how confidence intervals can be calculated for radiofrequency emitter position estimates based on time-of-arrival and frequency-of-arrival measurements taken at several satellites. These confidence intervals take the form of 50th and 95th percentile circles and ellipses to convey horizontal error and linear intervals to give vertical error. We consider both cases where an assumed altitude is and is not used. Analysis of velocity errors is also considered. We derive confidence intervals for horizontal velocity magnitude and direction including the case where the emitter velocity is assumed to be purely horizontal, i.e., parallel to the ellipsoid. Additionally, we derive an algorithm that we use to combine multiple position fixes to reduce location error. The algorithm uses all available data, after more than one location estimate for an emitter has been made, in a mathematically ...

2008-08-01

160

Evaluating Point Forecasts  

CERN Document Server

Typically, point forecasting methods are compared and assessed by means of an error measure or scoring function, such as the absolute error or the squared error. The individual scores are then averaged over forecast cases, to result in a summary measure of the predictive performance, such as the mean absolute error or the (root) mean squared error. I demonstrate that this common practice can lead to grossly misguided inferences, unless the scoring function and the forecasting task are carefully matched. Effective point forecasting requires that the scoring function be specified ex ante, or that the forecaster receives a directive in the form of a statistical functional, such as the mean or a quantile of the predictive distribution. If the scoring function is specified ex ante, the forecaster can issue the optimal point forecast, namely, the Bayes rule. If the forecaster receives a ...

2009-01-01

161

Dynamic and static error analyses of neutron radiography testing  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography systems are being used for real-time visualization of the dynamic behavior as well as time-averaged measurements of spatial vapor fraction distributions for two phase fluids. The data in the form of video images are typically recorded on videotape at 30 frames per second. Image analysis of he video pictures is used to extract time-dependent or time-averaged data. The determination of the average vapor fraction requires averaging of the logarithm of time-dependent intensity measurements of the neutron beam (gray scale distribution of the image) that passes through the fluid. This could be significantly different than averaging the intensity of the transmitted beam and then taking the logarithm of that term. This difference is termed the dynamic error (error in the time-averaged vapor fractions due to the inherent time-dependence of the measured data) and is separate from the static error (statistical ...

1999-03-01

162

Characterizing errors in digital elevation models and estimating the financial costs of accuracy  

British Library Electronic Table of Contents (United Kingdom)

Digital topographic models are the foundation of more advanced modeling applications and ultimately inform planning and decision making in many fields. Despite this, the error associated with these models and derived attributes is commonly overlooked. Little attention has been given in the scientific literature to the benefits gained from having less error in a model or to the corresponding cost associated with reducing model error by choosing one product over another. To address these gaps in knowledge we evaluated the error associated with five digital elevation models (DEMs) and derived attributes of slope and aspect relative to the same attributes derived from LiDAR data. We also estimated the acquisition and processing costs per square kilometer of the five test models and the LiDAR m...

2010-01-01

163

Cause analysis and preventives for human error events in Daya Bay NPP  

International Nuclear Information System (INIS)

Daya Bay Nuclear Power Plant is put into commercial operation in 1994 Until 1996, there are 368 human error events in operating and maintenance area, occupying 39% of total events. These events occurred mainly in the processes of maintenance, test equipment isolation and system on-line, in particular in refuelling and maintenance. The author analyses root causes for human errorievents, which are mainly operator omission or error procedure deficiency; procedure not followed; lack of training; communication failures; work management inadequacy. The protective measures and treatment principle for human error events are also discussed, and several examples applying them are given. Finally, it is put forward that key to prevent human error event lies in the coordination and management, person in charge of work, and good work habits of staffs.

164

Monte Carlo code comparisons for the calculation of absorbed dose per unit fluence in slab phantoms for electron energies from 50 keV to 10 MeV  

International Nuclear Information System (INIS)

The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).

165

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

British Library Electronic Table of Contents (United Kingdom)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as w...

2009-01-01

166

Comparison of fluid-dynamic modeling of flow with velocity-encoded MR imaging  

International Nuclear Information System (INIS)

This paper develops a fluid dynamic model using finite difference methods characterizing flow in phantoms simulating in vivo conditions and to compare those results with velocity encoded MR images. The phantom consisted of 1-inch (2.5-cm) tubing with semicircular insert and fluid with viscosity, T1, and T2 comparable to blood. Numeric solutions to Navier-Stokes equations for this system were obtained using finite difference methods, with velocity input function of zero at walls and parabolic at both ends. In resulting color raster (CR) images, color temperature represented velocity value. In velocity-encoded MR images acquired under the same flow conditions, phase is proportional to average velocity during application of flow-encoding gradients. Because these gradients are applied along one direction per acquisition, magnitude and direction of velocity are obtained.

1990-11-25

167

Improving the PSA quality in the human reliability analysis of pre-accident human errors  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the activities for improving the Probabilistic Safety Assessment (PSA) quality in the human reliability analysis (HRA) of the pre-accident human errors for the Korea Standard Nuclear Power Plant (KSNP). We evaluate the HRA results of the PSA for the KSNP and identify the items to be improved using the ASME PRA Standard. Evaluation results show that the ratio of items to be improved for pre-accident human errors is relatively high when compared with the ratio of those for post-accident human errors. They also show that more than 50% of the items to be improved for pre-accident human errors are related to the identification and screening analysis for them. In this paper, we develop the modeling guidelines for pre-accident human errors and apply them to the auxiliary feedwater system of the KSNP. Application results show that more than 50% of the items to be ...

2004-07-01

168

Improving the PSA quality in the human reliability analysis of pre-accident human errors  

International Nuclear Information System (INIS)

This paper describes the activities for improving the Probabilistic Safety Assessment (PSA) quality in the human reliability analysis (HRA) of the pre-accident human errors for the Korea Standard Nuclear Power Plant (KSNP). We evaluate the HRA results of the PSA for the KSNP and identify the items to be improved using the ASME PRA Standard. Evaluation results show that the ratio of items to be improved for pre-accident human errors is relatively high when compared with the ratio of those for post-accident human errors. They also show that more than 50% of the items to be improved for pre-accident human errors are related to the identification and screening analysis for them. In this paper, we develop the modeling guidelines for pre-accident human errors and apply them to the auxiliary feedwater system of the KSNP. Application results show that more than 50% of the items to be ...

2004-06-06

169

A Statistical Treatment of the Gamma-Ray Burst "No Host Galaxy" Problem; 1, Methodology  

CERN Document Server

If gamma-ray bursts originate in galaxies at cosmological distances, the host galaxy should be detected if a burst error box is searched deep enough; are the host galaxies present? We present and implement a statistical methodology which evaluates whether the observed galaxy detections in a burst's error box are consistent with the presence of the host galaxy, or whether all the detections can be attributed to unrelated background galaxies. This methodology requires the model-dependent distribution of host galaxy fluxes. While our methodology was derived for galaxies in burst error boxes, it can be applied to other candidate host objects (e.g., active galaxies) and to other types of error boxes. As examples, we apply this methodology to two published studies of burst error boxes. We find that the nine error boxes observed by Larson and McLean (1997) are too ...

1997-01-01

170

Dating divergences in the Fungal Tree of Life: review and new analyses.  

Science.gov (United States)

The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...

171

Particle Flow at CMS and the ILC  

CERN Document Server

This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...

2010-01-01

172

Experimental compliance calibration for the mixed-mode bending (MMB) specimen  

Energy Technology Data Exchange (ETDEWEB)

A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.

1997-12-31

173

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...

2010-10-15

174

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...

2010-10-01

175

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

176

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

177

Analysis of installation damage tests for LRFD calibration of reinforced soil structures  

British Library Electronic Table of Contents (United Kingdom)

North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...

2011-01-01

178

A refined lack-of-fit statistic to calibrate pesticide fate models for responsive systems  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...

2009-01-01

179

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

180

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous ...

2009-07-21

181

IMRT verification by three-dimensional dose reconstruction from portal beam measurements  

International Nuclear Information System (INIS)

A method of reconstructing three-dimensional, in vivo dose distributions delivered by intensity-modulated radiotherapy (IMRT) is presented. A proof-of-principle experiment is described where an inverse-planned IMRT treatment is delivered to an anthropomorphic phantom. The exact position of the phantom at the time of treatment is measured by acquiring megavoltage CT data with the treatment beam and a research prototype, flat-panel, electronic portal imaging device. Immediately following CT imaging, the planned IMRT beams are delivered using the multiple-static field technique. The delivered fluence is sampled using the same detector as for the CT data. The signal measured by the portal imaging device is converted to primary fluence using an iterative phantom-scatter estimation technique. This primary fluence is back-projected through the previously acquired megavoltage CT model of the phantom, with ...

2002-08-01

182

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

183

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

Energy Technology Data Exchange (ETDEWEB)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: (1) conventional radiography (CXR), (2) low kV conventional radiography (Low), (3) Fuji computed radiography (FCR), (4) bone images with conventional singles exposure energy subtraction (ES) and (5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-08-01

184

Evaluation of calcification in pulmonary nodules using bone images obtained with single exposure energy subtraction  

International Nuclear Information System (INIS)

Bone images obtained by single exposure dual energy subtraction with computed radiography, a new image processing method, were evaluated for the detectability of calcification in lung nodules in both phantom and clinical studies. In the phantom study, five simulated nodules containing known and uniformly distributed amounts of calcium hydroxide were placed in a human chest phantom and images were obtained the following five techniques: 1) conventional radiography (CXR), 2) low kV conventional radiography (Low), 3) Fuji computed radiography (FCR), 4) bone images with conventional singles exposure energy subtraction (ES) and 5) bone image with fine single exposure energy subtraction (FES). The detectability of calcification in the simulated nodules was evaluated by six radiologists using ROC analysis and two-way analysis of variance. In the clinical study, images of 42 lung nodules (21 calcified lung nodules and 21 ...

1995-01-01

185

A novel method to characterize the MTF in 3D for computed mammotomography  

Science.gov (United States)

A novel phantom has been developed to measure the modulation transfer function (MTF) in 3D for x-ray computed tomography. The phantom consists of three tungsten wires, positioned nearly orthogonal to each other. Simultaneous measurements of the MTF are taken at various locations along the three orthogonal reconstructed planes. Our computed mammotomography (CmT) system uses a Varian Paxscan 2520 digital x-ray detector which can be positioned anywhere in ~2pi steradian band and can have arbitrary trajectories. With a half-cone beam geometry and with the phantom positioned near the center of rotation, projection images are acquired over 360 degrees. Various 3D orbits are evaluated including vertical axis of rotation and saddle. Reconstructions were performed using an iterative ordered-subsets transmission algorithm on rebinned projection images, using various numbers of iterations. Rotation of reconstructed slices isolated ...

2006-03-01

186

A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography  

International Nuclear Information System (INIS)

Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast ...

1999-11-01

187

Binary Error Correcting Network Codes  

CERN Document Server

We consider network coding for networks experiencing worst-case bit-flip errors, and argue that this is a reasonable model for highly dynamic wireless network transmissions. We demonstrate that in this setup prior network error-correcting schemes can be arbitrarily far from achieving the optimal network throughput. We propose a new metric for errors under this model. Using this metric, we prove a new Hamming-type upper bound on the network capacity. We also show a commensurate lower bound based on GV-type codes that can be used for error-correction. The codes used to attain the lower bound are non-coherent (do not require prior knowledge of network topology). The end-to-end nature of our design enables our codes to be overlaid on classical distributed random linear network codes. Further, we free internal nodes from having to implement potentially computationally intensive link-by-link ...

2011-01-01

188

Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications  

CERN Document Server

Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.

2007-01-01

189

Proposal of procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions; Proposta de procedimentos para evitar erros em radioterapia baseados em licoes aprendidas de exposicoes acidentais  

Energy Technology Data Exchange (ETDEWEB)

In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment ...

2007-07-01

190

Interpolation theory and influence of boundary conditions on room air diffusion  

Energy Technology Data Exchange (ETDEWEB)

This paper analyses the errors caused by interpolation from existing cases for assessing indoor air flow, air quality and thermal comfort in an office. A sensitivity study is then provided to determine the influence of several boundary conditions on indoor air diffusion. The research is conducted numerically by using a low-Reynolds-number k-{epsilon} model. It can be concluded that the interpolation errors caused by the variations of solar radiation, window size, heat source location due to lighting, and the surface temperatures of interior walls are small and can be quantitatively determined. But it is difficult to estimate the errors introduced by the variations of furniture location and size. (author).

1991-01-01

191

Influence of changes in the composition of Kh18N10T steel on the results of measurement of its thickness by the radiometric method  

International Nuclear Information System (INIS)

The additional error in measurement of the thickness of Kh18N10T steel for possible changes in composition with an energy of the photons of ionizing radiation of 10-80 keV was evaluated. The desirability of use of a type REIS-I x-ray emitter in measurement of the thickness of steel up to 1 mm is shown. The instrument provides measurement of the thickness of steel in the 0.1-1.0 mm range with a reproducibility of the results with an error not exceeding 0.5-1.0%. The measurement error with corrugations characteristic of bellows does not exceed 5%.

192

Development of an analysis rule of diagnosis error for standard method of human reliability analysis  

International Nuclear Information System (INIS)

This paper presents the status of development of Korea standard method for Human Reliability Analysis (HRA), and proposed a standard procedure and rules for the evaluation of diagnosis error probability. The quality of KSNP HRA was evaluated using the requirement of ASME PRA standard guideline, and the design requirement for the standard HRA method was defined. Analysis procedure and rules, developed so far, to analyze diagnosis error probability was suggested as a part of the standard method. And also a study of comprehensive application was performed to evaluate the suitability of the proposed rules.

2003-10-01

193

A practical scheme for error control using feedback  

CERN Document Server

We describe a scheme for quantum error correction that employs feedback and weak measurement rather than the standard tools of projective measurement and fast controlled unitary gates. The advantage of this scheme over previous protocols (for example Ahn et. al, PRA, 65, 042301 (2001)), is that it requires little side processing while remaining robust to measurement inefficiency, and is therefore considerably more practical. We evaluate the performance of our scheme by simulating the correction of bit-flips. We also consider implementation in a solid-state quantum computation architecture and estimate the maximal error rate which could be corrected with current technology.

2004-01-01

194

UNS YMSCP QA support task: Quarterly technical progress report, January 1, 1991--June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)

1991-07-30

195

THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA  

Science.gov (United States)

tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...

196

Spectral Cross-calibration of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT Data using Gamma-Ray Bursts  

CERN Document Server

We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...

2010-01-01

197

Measurements of Spectral Characteristics of Swimmer Targets ...  

Science.gov (United States)

... 3.0 Radar Measurements 3-1 3. 1 Spectral Density Measurements 3-2 3. 1. 1 System Calibration 3-3 ... 3. 1 SPECTRAL DENSITY MEASUREMENTS ...

1974-05-01

198

Granite Countertops and Radiation | Radiation Protection | US EPA  

Wastenet

... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...

199

Exploding Bridgewire Electrical System Test Unit.  

Science.gov (United States)

The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...

1964-01-01

200

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...

2000-03-01

201

Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.  

Science.gov (United States)

This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...

1979-01-01

202

COSPIN-ANISOTROPY TELESCOPE for ULY - PDS - NASA  

Science.gov (United States)

To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...

203

Binary pseudo-random gratings and arrays for calibration of the modulation transfer function of surface profilometers: recent developments  

Energy Technology Data Exchange (ETDEWEB)

The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...

2009-07-07

204

The approximate maximum-likelihood certificate  

CERN Document Server

A new property which relies on the linear programming (LP) decoder, the approximate maximum-likelihood certificate (AMLC), is introduced. When using the belief propagation decoder, this property is a measure of how close the decoded codeword is to the LP solution. Using upper bounding techniques, it is demonstrated that the conditional frame error probability given that the AMLC holds is, with some degree of confidence, below a threshold. In channels with low noise, this threshold is several orders of magnitude lower than the simulated frame error rate, and our bound holds with very high degree of confidence. In contrast, showing this error performance by simulation would require very long Monte Carlo runs. When the AMLC holds, our approach thus provides the decoder with extra error detection capability, which is especially important in applications requiring high data integrity.

2011-01-01

205

Teleogramma gracile  

Science.gov (United States)

... Congo. It is probable that the type locality Matadi is in error and is the location from ... specimens of this species have been collected between Matadi and Luozi. (click map to view...

206

Space Science - NASA Headquarters  

Science.gov (United States)

Canada will provide telescope baffles and fine error sensor assemblies. ..... ( Ongoing) Flight tests aboard sounding rockets and balloon planned for FY 1995. .... the effects of incoming energetic particles and solar radiation on the ...

207

Real-Time Stability and Control Derivative Extraction From F-15 - NASA  

Science.gov (United States)

and the estimated parameter covariance matrix is. 5. (25) where p in this case is the number of elements in the vector . The parameter standard errors, ?, ...

208

Publication Year - NASA Technical Reports Server  

Science.gov (United States)

Abstract: Inertial navigation error analysis of space vehicle during reentry. NASA Center: Ames Research Center Publication Year: 1963 ...

209

Linac automated beam phase control system.  

Energy Technology Data Exchange (ETDEWEB)

Adjustment of the rf phase in a linear accelerator is crucial for maintaining optimal performance. If phasing is incorrect, the beam will in general have an energy error and increased energy spread. While an energy error can be readily detected and corrected using position readings from beam position monitors at dispersion locations, this is not helpful for correcting energy spread in a system with many possible phase errors. Uncorrected energy spread results in poor capture efficiency in downstream accelerators, such as the Advanced Photon Source's (APS's) particle accumulator ring (PAR) or booster synchrotron. To address this issue, APS has implemented beam-to-rf phase detectors in the linac, along with software for automatic correction of phase errors. We discuss the design, implementation, and performance of these detectors and how they improved APS top-up operations.

2006-01-01

210

Human factors  

Energy Technology Data Exchange (ETDEWEB)

This is a presentation on Human Factors in reactor operations. It discusses issues that deal with power plant operations, training and design, operational effectiveness and safety, supporting people to achieve effective and error free performance.

2002-07-01

211

George C. - NASA Technical Reports Server  

Science.gov (United States)

Indicated inertial navigation error and required update frequency. phasing, and times). Docking Phase. Range; range rate. Clock angle; clock angle rate ...

212

Evaluating concentration estimation errors in ELISA microarray experiments  

UK PubMed Central (United Kingdom)

BackgroundEnzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to estimate a protein's concentration in a sample. Deploying ELISA in a microarray format permits simultaneous...Full Text Available

213

Contamination Effects of Satellite Material Outgassing ...  

Science.gov (United States)

... A detailed analysis of QCM errors is ... Surface Effects of Satellite Outgassing Products." AIAA Journal ... 9. Rauschenbach, H. S. Solar Cell Array Design ...

1990-12-01

214

Concurrent Error-Detecting Codes for Arithmetic Processors  

Science.gov (United States)

2 is self-checking as described by Kolupaev. (ref. 21). ..... Kolupaev, S. G.: Self-Testing Residue. Trees. TR-49, Digital Systems ...

215

Competitive Mean-Squared Error Beamforming  

Science.gov (United States)

... Therefore we develop a competitive beamforming ap- proach, in which the beamformer is designed to minimize the worst-case regret over all s(t ...

2004-12-20

216

CHANEXTDFS - Chandra Extended Deep Field South Survey Point Source ...  

Science.gov (United States)

Jan 25, 2006 ... Source positions are determined using matched-filter and centroiding .... The upper 1-sigma statistical error in the full-band counts. ...

217

Assessment of informatization for the dispensing of medications at a university hospital  

UK PubMed Central (United Kingdom)

INTRODUCTIONInformatics and automation are important tools for the reduction of work, errors and costs in a hospital pharmacy.OBJECTIVESTo describe...Full Text Available

2010-04-01

218

An Extended Kalman Filter for Use in a Shared Aperture ...  

Science.gov (United States)

... used to track a point source target ... A one sigma tracking error of .2 ... LOOKING INFRARED SYSTEMS, *KALMAN FILTERING, SIGNAL PROCESSING ...

1978-12-01

219

A Detailed Investigation on Human-Related Unplanned Reactor Trip Events in Korea  

International Nuclear Information System (INIS)

Human errors have been reported as one of the most significant causes of major events in nuclear power plants (NPPs). For example, Kim and Park found that about 23% of the major events that occurred at NPPs in Republic of Korea from 1986 to 2006 were caused by human errors. For this reason, a detailed analysis on human errors is an important task for increasing the safety of NPPs. Kim and Choi?2 analyzed 100 human-related unplanned reactor trip events in the Republic of Korea from 1986 to 2006 to consider the type of human errors based on the simple path model for human-induced unplanned reactor trips developed by Kim and Park. In this paper, we will investigate and perform a detailed analysis of the data to identify human-related unplanned reactor trip trends

2010-10-01

220

A Comparative Study of Weights and Sizes of Flat-Plate ...  

Science.gov (United States)

... this correction results In only a email error, since the isothoraal tests wore run at roon tomporcturo, -nd simplifies the reduction of isotherme! ...

1947-07-01

221

/ /tLc - NASA Technical Reports Server  

Science.gov (United States)

Inertial navigation error propagation. Hypersonic entry guidance techniques. Ablation effects on hypersonic aero-. Primary navigation and guidance ...

222

Residential vertical geothermal heat pump system models: Calibration to data  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.

1997-12-31

223

Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:  

Energy Technology Data Exchange (ETDEWEB)

A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.

1997-06-01

224

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

225

Capability of the PAMELA Time-Of-Flight to identify light nuclei: results from a beam test calibration  

CERN Document Server

PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.

2008-01-01

226

Software framework and jet energy scale calibration in the ATLAS experiment; Environnement logiciel et etalonnage de l'echelle en energie des jets dans l'experience ATLAS  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This calibration ...

2006-07-01

227

Calibration of the Capintec CRC-712M dose calibrator for "1"8F  

International Nuclear Information System (INIS)

Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...

2006-04-01

228

Physics of locked modes in ITER: Error field limits, rotation for obviation, and measurement of field errors  

Energy Technology Data Exchange (ETDEWEB)

The existing theoretical and experimental basis for predicting the levels of resonant static error field at different components m,n that stop plasma rotation and produce a locked mode is reviewed. For ITER ohmic discharges, the slow rotation of the very large plasma is predicted to incur a locked mode (and subsequent disastrous large magnetic islands) at a simultaneous weighted error field ({Sigma}{sub 1}{sup 3}w{sub m1}B{sup 2}{sub rm1}){sup {1/2}}/B{sub T} {ge} 1.9 x 10{sup -5}. Here the weights w{sub m1} are empirically determined from measurements on DIII-D to be w{sub 11} = 0. 2, w{sub 21} = 1.0, and w{sub 31} = 0. 8 and point out the relative importance of different error field components. This could be greatly obviated by application of counter injected neutral beams (which adds fluid flow to the natural ohmic electron drift). The addition of 5 MW of 1 MeV beams at 45{degrees} injection would increase the ...

1997-02-01

229

Optimal Knot Selection for Least-squares Fitting of Noisy Data with Spline Functions  

Energy Technology Data Exchange (ETDEWEB)

An automatic data-smoothing algorithm for data from digital oscilloscopes is described. The algorithm adjusts the bandwidth of the filtering as a function of time to provide minimum mean squared error at each time. It produces an estimate of the root-mean-square error as a function of time and does so without any statistical assumptions about the unknown signal. The algorithm is based on least-squares fitting to the data of cubic spline functions.

2008-05-15

230

Optical voltage reference  

Energy Technology Data Exchange (ETDEWEB)

An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

1992-12-31

231

Harmonic decomposition of orbit data for multipole analysis  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a simple analysis procedure that transforms a set of beamline orbit data into a set of harmonic orbits of first, second, and third order or higher. Each harmonic orbit can be studied individually to identify errors of the specific order with minimum interference from other orders. Effectively these are orbits caused by kicks, due to harmonic errors, propagated through linear lattice. Examples from accelerator study will be presented. The application and inherent limitations of this analysis procedure are discussed.

2005-05-01

232

Corrections for non-homogeneity of the sample in Moessbauer f-factor measurements  

Energy Technology Data Exchange (ETDEWEB)

We describe a procedure for correcting the systematic errors in the Moessbauer f-factor measurement due to non-homogeneous effective thickness of the sample. To be more precise, we show that, if the mass of the sample is determined by means of X- or {gamma}-ray absorption, it is possible to establish experimental conditions so that the error on f due to material non-homogeneity in the sample is minimized.

2002-06-01

233

Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection  

Energy Technology Data Exchange (ETDEWEB)

A novel method to detect and correct inaccuracies in a set of unconstrained dense correspondences between two images is presented. Starting with a robust, general-purpose dense correspondence algorithm, an initial pose estimate and dense 3D scene reconstruction are obtained and bundle-adjusted. Reprojection errors are then computed for each correspondence pair, which is used as a metric to distinguish high and low-error correspondences. An affine neighborhood-based coarse-to-fine iterative search algorithm is then applied only on the high-error correspondences to correct their positions. Such an error detection and correction mechanism is novel for unconstrained dense correspondences, for example not obtained through epipolar geometry-based guided matching. Results indicate that correspondences in regions with issues such as occlusions, repetitive patterns and moving objects can be identified and ...

2009-11-23

234

A Human reliability analysis of post-accident human errors in the PSA of KSNP  

International Nuclear Information System (INIS)

Korea Atomic Energy Research Institute, using the ASME PRA Standard, evaluated the PSA model of the Korea Standard Nuclear Power Plant (KSNP) and identified the items to be improved to enhance its quality. The new risk monitor PSA model for the KSNP of which quality was enhanced is called as PRiME-U3i. The evaluation results of human reliability analysis (HRA) of the post-accident human errors in the PSA model of the KSNP showed that 10 items among 19 items of supporting requirements for those in the ASME PRA Standard were identified as them to be improved. Thus, we newly carried out a HRA for post-accident human errors for the KSNP PSA model as the target of grading its quality above ASME PRA Standard Category I+. Following tasks were additionally major tasks performed in the HRA of post-accident human errors of PRiME-U3i compared with the previous PSA model of the KSNP: interviews with operators in the collection and ...

2004-10-28

235

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

236

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

237

The Contribution of Sympathetic Mechanisms to Postamputation Phantom and Residual Limb Pain: A Pilot Study  

British Library Electronic Table of Contents (United Kingdom)

Postamputation pain (PAP) affects over 60% of major limb amputees. One of the main challenges in treating PAP is the difficulty involved in identifying pain mechanism(s), which pertains to both residual limb pain (RLP) and phantom limb pain (PLP). In this study, sympathetic blocks were performed on 17 major limb amputees refractory to treatment, including 2 placebo-controlled blocks done for bilateral amputations. One hour postinjection, mean RLP scores at rest declined from 5.2 (SD 2.8) to 2.8 (SD 2.6) (P = .0002), and PLP decreased from 5.3 (SD 3.1) to 2.3 (SD 2.1) (P = .0009). By 1 week, mean pain scores for RLP and PLP were 4.3 (SD 2.9) and 4.2 (SD 3.0), respectively. Overall, 8 of 16 (50%) patients experienced ?50% reduction in RLP 1-hour postinjection, with the beneficial effects ...

2011-01-01

238

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...

1996-12-01

239

Radiation exposure of children in pediatric radiology. Pt. 6. Conversion factors for reconstruction of organ dose in abdominal radiography; Zur Strahlenexposition von Kindern in der paediatrischen Radiologie. T. 6. Konversionsfaktoren zur Rekonstruktion von Organdosen bei Abdomenaufnahmen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: calculation of conversion coefficients for the reconstruction of organ doses from entrance doses for abdomen radiographs of 0, 1, 5, 10, 15, and 30-year-old patients in conventional pediatric radiology for the radiographic settings recommended by the German and European guidelines for quality management in diagnostic radiology. Materials und method: using the commercially available personal computer program PCXMC developed by the Finnish Center for Radiation and Nuclear Safety (Saeteilyturvakeskus STUK), conversion coefficients for conventional abdomen radiographs were calculated performing Monte Carlo simulations in mathematical hermaphrodite phantom models describing patients of different ages. The possible clinical variation of beam collimation was taken into consideration by defining optimal and suboptimal radiation fields on the phantoms' surfaces. Results: conversion coefficients for the reconstruction of organ does in ...

2009-10-15

240

Measurement of electron energy fluence spectra from electron beam therapy machines  

Energy Technology Data Exchange (ETDEWEB)

A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. CYLTRAN, a coupled electron-photon Monte Carlo transport code, ...

1984-01-01

241

FDTD analysis of body-core temperature elevation in children and adults for whole-body exposure  

Energy Technology Data Exchange (ETDEWEB)

The temperature elevations in anatomically based human phantoms of an adult and a 3-year-old child were calculated for radio-frequency whole-body exposure. Thermoregulation in children, however, has not yet been clarified. In the present study, we developed a computational thermal model of a child that is reasonable for simulating body-core temperature elevation. Comparison of measured and simulated temperatures revealed thermoregulation in children to be similar to that of adults. Based on this finding, we calculated the body-core temperature elevation in a 3-year-old child and an adult for plane-wave exposure at the basic restriction in the international guidelines. The body-core temperature elevation in the 3-year-old child phantom was 0.03 deg. C at a whole-body-averaged specific absorption rate of 0.08 W kg{sup -1}, which was 35% smaller than in the adult female. This difference is attributed to the child's higher body surface ...

2008-09-21

242

Experimental evaluation of angularly-variable fiber geometry for targeting depth-resolved reflectance from layered epithelial tissue phantoms  

Science.gov (United States)

The aim of the present study focuses on experimentally demonstrating the efficacy of using angularly-variable fiber geometry to achieve the desired tissue-layer selection and probing depths with the further objective of enhancing the sensitivity and specificity of spectral diagnosis in stratified architectures that resemble human cervical epithelia. The morphological and biochemical features of epithelial tissue vary in accordance with tissue depths; consequently, the accuracy of spectroscopic diagnosis of epithelial dysplasia may be enhanced by probing the optical properties of this tissue. When correlated to cellular dysplasia, layer-specific changes in tissue optical properties may be deciphered by reflectance spectroscopy coupled with angularly-variable fiber geometry. This study addresses the utility of using such angularly-variable fiber geometry for resolving spatially-specific spectral signatures of tissue pathology. This is accomplished by interpreting and analyzing the ...

2007-03-01

243

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in the retrocardiac and subdiaphragmatic regions, respectively. This may have implications for the value of ...

1987-12-01

244

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate imaging modality to evaluate the major airway in children. (author).

1986-01-01

245

Calculating electron dose using a convolution/superposition method. 120  

International Nuclear Information System (INIS)

The calculation of electronn beam dose using an algorithms similar to convolution/superposition methods for photon beams [1,2,3,4] is explored. The distribution of dose deposited by a number of monoenergetic, point-monodirectional electron pencil beams is first determined using the Monte Carlo method [5,6]. These elementary distributions are combined to model distributions that would result from the spectrum of incident energies and angles [6,7] present in a clinical beam. These modified distributions are then stored for use as kernels in the dose calculation. In the case of a homogeneous phantom, the relative fluence distribution is convolved with the stored kernels to obtain thhe dose distributions in 3 dimensions. Since the kernels cannot be assumed to be spatially invariant in a heterogeneous water-like phantom, the dose deposited on paths from the interaction site to all the dose deposition sites is approximated by scaling the kernels to ...

246

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for ...

1980-10-31

247

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...

2010-10-01

248

An adaptive filter to approximate the Bayesian strategy for sonographic beamforming.  

Science.gov (United States)

A first-principles task-based approach to the design of medical ultrasonic imaging systems for breast lesion discrimination is described. This study explores a new approximation to the ideal Bayesian observer strategy that allows for object heterogeneity. The new method, called iterative Wiener filtering, is implemented using echo data simulations and a phantom study. We studied five lesion features closely associated with visual discrimination for clinical diagnosis. A series of human observer measurements for the same image data allowed us to quantitatively compare alternative beamforming strategies through measurements of visual discrimination efficiency. Employing the Smith-Wagner model observer, we were able to breakdown efficiency estimates and identify the processing stage at which performance losses occur. The methods were implemented using a commercial scanner and a cyst phantom to explore development of spatial filters for systems ...

2010-07-19

249

A convolution/superposition method using primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance: a theoretical study on 10-MV X-ray dose calculations in thorax-like phantoms  

British Library Electronic Table of Contents (United Kingdom)

A convolution/superposition method is proposed for use with primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. It should be noted that the number of energy bins is usually about ten, and that the reconstructed X-ray spectra can reasonably be applied to media with a wide range of effective Z numbers, ranging from water to lead. The study was carried out for 10-MV X-ray doses in water and thorax-like phantoms with the use of open-jaw-collimated fields. The dose calculations were made separately for primary, scatter, and electron contamination dose components, for which we used two extended radiation sources: one was on the X-ray target and the other on the flattening filter. To calculate the in-air beam intensities at po...

2011-01-01

250

Radiation exposure of patients and operators during interventional radiology  

International Nuclear Information System (INIS)

Surface doses received by patients and operators were measured during 30 interventional radiological procedures (ten percutaneous transhepatic biliary drainages, ten percutaneous nephrostomies, ten percutaneous transluminal angioplasties). In addition, organ doses to the patient were determined using an Alderson-Rando phantom. These served as a basis for calculating the so-called somatic dose indices. It was found that the somatic radiation risk to the patient is relatively small despite prolonged periods of fluoroscopy. However, exposure of the hands and lenses of the operator could easily reach the limits thought acceptable while carrying out these procedures with additional angiography. (orig).

1986-01-01

251

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

Energy Technology Data Exchange (ETDEWEB)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-08-01

252

Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography  

International Nuclear Information System (INIS)

Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).

1991-01-01

253

Organ doses and integral doses in X-ray diagnosis of the chest and of the head  

International Nuclear Information System (INIS)

Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.

1977-04-01

254

Mathematical child phantom for the calculation of dose to the organs at risk  

Energy Technology Data Exchange (ETDEWEB)

In order to calculate the doses received by the organs of 530 children treated by radiation for cancer between 1945 and 1969 at the G. Roussy Institute, we have developed a computer program for organ location calculation. To calculate the location of each child's organs of interest at the time of the treatment, only two parameters are necessary; sex and height or sex and age when the height at the time of the treatment is unknown. The algorithm is based on the metric studies of growth known as auxology. Each organ is located by one point representing its center. The model has been checked on 100 healthy children.

1988-05-01

255

Electron beam therapy in carcinoma of the buccal mucosa  

Energy Technology Data Exchange (ETDEWEB)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

1990-10-01

256

Electron beam therapy in carcinoma of the buccal mucosa  

International Nuclear Information System (INIS)

Electron beam therapy has often been used for radiation therapy of carcinomas of the buccal mucosa, though side effects, including stomatitis and dermatitis, are known to exist. We experimented using the additional back scatter and transit with the phantom under a lead plate within the irradiation field, in order to better focus the dose on the target volume moreover, we fabricated a mouthpiece fitted with a lead plate shaped to the target volume, and with respect to the influence of the mouthpiece on stomatitis and dermatitis, obtained good clinical results. (author).

257

Dual-field rotational (DFR) technique for total-skin electron-beam therapy (TSEBT)  

Energy Technology Data Exchange (ETDEWEB)

Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.

1987-08-01

258

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a water tank where used to measure depth ...

259

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

260

Experimental studies of compact real-time neutron dosimeters  

International Nuclear Information System (INIS)

Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential beam tube of the TRIGA Mark II reactor at Kansas State University were measured. Then, thermoluminescent dosimeters (some ...

2008-06-01

261

Convolution/superposition using the Monte Carlo method  

International Nuclear Information System (INIS)

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator ...

2003-07-21

262

Experimental investigation of dose calibrator response for "1"2"5I brachytherapy solutions contained in 5 mL plastic syringes and 2 mL conical glass v-vials as a function of filling mass  

International Nuclear Information System (INIS)

The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...

2002-07-01

263

Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code  

Energy Technology Data Exchange (ETDEWEB)

In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...

1998-12-01

264

[Comparison of wound morphology following gunshots by machine guns and sub-machine guns].  

Science.gov (United States)

Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...

265

The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs  

CERN Document Server

We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...

2009-01-01

266

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...

2010-01-01

267

Metrology measurement capabilities  

Energy Technology Data Exchange (ETDEWEB)

Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...

1997-06-01

268

Heat pump modeling in TRNSYS  

Energy Technology Data Exchange (ETDEWEB)

Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...

1997-11-01

269

Development of highly reliable screening by using x-ray fluorescence spectrometry. Applications to determine lead in tin plated and tin-bismuth plated samples  

International Nuclear Information System (INIS)

A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)

2009-03-01

270

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

Energy Technology Data Exchange (ETDEWEB)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-15

271

Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art  

International Nuclear Information System (INIS)

The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...

2010-01-01

272

Validity of the CT to attenuation coefficient map conversion methods  

International Nuclear Information System (INIS)

The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result.

2004-04-27

273

Unified Analysis of the Average Gaussian Error Probability for a Class of Fading Channels  

CERN Document Server

This paper focuses on the analysis of average Gaussian error probabilities in certain fading channels, i.e. we are interested in E[Q((p {\\gamma})^(1/2))] where Q(.) is the Gaussian Q-function, p is a positive real number and {\\gamma} is a nonnegative random variable. We present a unified analysis of the average Gaussian error probability, derive a compact expression in terms of the Lauricella FD^(n) function that is applicable to a broad class of fading channels, and discuss the relation of this expression and expressions of this type recently appeared in literature. As an intermediate step in our derivations, we also obtain a compact expression for the outage probability of the same class of fading channels. Finally, we show how this unified analysis allows us to obtain novel performance analytical results.

2011-01-01

274

Simulation technologies for cosmic ray neutron-induced soft errors: Models and simulation systems  

Energy Technology Data Exchange (ETDEWEB)

The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and [alpha]-induced SE analysis.

1999-06-01

275

Simulation technologies for cosmic ray neutron-induced soft errors: Models and simulation systems  

International Nuclear Information System (INIS)

The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and #alpha#-induced SE analysis

1999-06-01

276

Simulation study of the influence of the ionospheric layer height in the thin layer ionospheric model  

British Library Electronic Table of Contents (United Kingdom)

This work aims to contribute to the understanding of the influence of the ionospheric layer height (ILH) on the thin layer ionospheric model (TLIM) used to retrieve ionospheric information from the GNSS observations. Particular attention is paid to the errors caused on the estimation of the vertical total electron content (vTEC) and the GNSS satellites and receivers inter-frequency biases (IFB), by the use of an inappropriate ILH. The work relies upon numerical simulations performed with an empirical model of the Earth?s ionosphere: the model is used to create realistic but controlled ionospheric scenarios and the errors are evaluated after recovering those scenarios with the TLIM. The error assessment is performed in the Central and the northern part of the South American continents, a re...

2011-01-01

277

Quantifying costs of forecast errors: A case study of the warehouse environment  

British Library Electronic Table of Contents (United Kingdom)

Our study evaluates the impact of forecast errors on organizational cost by simulating a labor-intensive warehouse environment using realistic cost data from a case study. Unlike past studies that measure forecast error in terms of forecast standard deviation, our study also considers the impact of forecast bias, and the complex interaction between these variables. Two cases of organizational cost curves are considered, with differing and asymmetric structures. Results find forecast bias to have a considerably greater impact on organizational cost than forecast standard deviation. Particularly damaging is a high bias in the presence of high forecast standard deviation. Although biasing the forecast in the least costly direction is shown to yield lower costs, sensitivity analysis shows that...

2009-01-01

278

New Permeameters for In Situ Characterization of Unsaturated Heterogeneous Permeability: Development, Design, Testing, and Application  

Energy Technology Data Exchange (ETDEWEB)

The original objective of our EMSP research was to design, develop, and test new in situ field permeameters for use in spatial variability studies of unsaturated hydraulic properties. We initially focused on activities related to development and testing of techniques for inverting permeameter data, development of numerical tools for data inversion, error evaluation for permeameter design, and permeameter component design. However, the results of error evaluations for permeameter design caused us to redirect our research, and reformulate our research objectives. We discovered that small, simple measurement errors lead to significant bias in the estimated hydraulic properties and their spatial statistics. Our reformulated research objective became the evaluation of the origin, impact and relevance of spatial bias in field-and laboratory-estimated unsaturate hydraulic properties, with an emphasis on spatial statistics and the ...

2001-12-01

279

Measurement and analysis of neutron-induced soft errors in sub-half-micron CMOS circuits  

Energy Technology Data Exchange (ETDEWEB)

Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.

1998-07-01

280

Invariant asymptotic observers  

CERN Document Server

This paper presents three non-linear asymptotic observers corresponding to three examples of engineering interest: a chemical reactor, a non-holonomic car, and an inertial navigation system. For each example, the design is based on physical symmetries. This motivates the theoretical development of invariant observers, i.e, symmetry-preserving observers. We consider an observer to consist in a copy of the system equation and a correction term, and we give a constructive method (based on the Cartan moving-frame method) to find all the symmetry-preserving correction terms. They rely on an invariant frame (a classical notion) and on an invariant output-error, a less standard notion precisely defined here. For each example, the convergence analysis relies also on symmetries consideration with a key use of invariant state-errors. For the non-holonomic car and the inertial navigation system, the invariant state-errors is shown to ...

2006-01-01

281

Fault diagnosis on bottle filling plant using genetic-based neural network  

British Library Electronic Table of Contents (United Kingdom)

Timely detection of the pneumatic system problems is important in industry. Many techniques have been employed to solve this problem. In this paper, Genetic Algorithm (GA) based optimal configuration of neural networks is proposed for fault diagnostic of bottle filling systems. Back-propagation is used for neural networks algorithm. The back-propagation algorithm had six inputs and one output. A fitness function was designed to the minimize execution time of ANN model by keeping the number of hidden layer(s) and nodes as low as possible while the mean square error of estimated output error is minimized. The designed GA-ANN combination and the graphical user interface (GUI) eliminate the trial and error process for selection of the fastest and most accurate configuration. The performance of...

2011-01-01

282

Assimilating remote sensing and in situ observations into a coastal model of northern South China Sea using ensemble Kalman filter  

British Library Electronic Table of Contents (United Kingdom)

Major forecast errors on the background error covariance from initial conditions, atmospheric forcing, model open boundary conditions, and the river discharges are examined in a coastal model of northern South China Sea. The analysis of background error covariance matrix produced by model ensemble shows that the perturbations of the initial conditions and atmospheric forcing play major roles in producing and maintaining the amplitude of ensemble spread except for the sea surface height (SSH) field. The perturbation of model open boundary conditions can influence ensemble spread of all variables and covariance between temperature and velocity or between temperature and SSH. The perturbation of river discharge mainly affects the covariance of salinity in river estuary. A data assimilation ex...

2011-01-01

283

A nodal integral method for neutron diffusion in hexagonal geometry  

International Nuclear Information System (INIS)

A nodal integral method is derived for the monoenergetic, steady-state, fixed source neutron diffusion equation in hexagonal geometry based on a coordinate transformation that maps a parallelogram into a rectangle. The new hexagonal nodal diffusion method is implemented in the computer code HND where the discrete-variable equations are solved via an iterative scheme. Because the new method's equations are derived for a rhombus, they can be solved on a sequence of embedded meshes to study the method's error order. Indeed a preliminary numerical error analysis reveals a second-order error in the mesh size, and comparison with finite difference results obtained with the finite difference based BOLD-VENTURE code indicate the superior accuracy of our new nodal method.

1992-03-08

284

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

285

The KCAL VERA 22 GHz calibrator survey  

CERN Document Server

We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.

2011-01-01

286

On the problem of magnitude calibration of palaeoearthquakes  

British Library Electronic Table of Contents (United Kingdom)

Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...

2011-01-01

287

Groundtruth approach to accurate quantitation of fluorescence microarrays  

Energy Technology Data Exchange (ETDEWEB)

To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

2000-12-01

288

Enamel-Calibrated Lamellar Bone Reveals Long Period Growth Rate Variability in Humans  

British Library Electronic Table of Contents (United Kingdom)

Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...

2011-01-01

289

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].

2005-06-11

290

Comparison of constitutive models for plastic-bonded explosives  

British Library Electronic Table of Contents (United Kingdom)

A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...

2008-01-01

291

Binary pseudo-random grating as a standard test surface formeasurement of modulation transfer function of interferometricmicroscopes  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...

2007-07-25

292

An application of UV-derivative spectrophotometry and bivariate calibration algorithm for study of photostability of levomepromazine hydrochloride  

British Library Electronic Table of Contents (United Kingdom)

Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.

2008-01-01

293

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

294

The molecular lesion in the alpha-N-acetylgalactosaminidase gene that causes angiokeratoma corporis diffusum with glycopeptiduria.  

UK PubMed Central (United Kingdom)

Angiokeratoma corporis diffusum with glycopeptiduria is a recently recognized inborn error of glycoprotein catabolism resulting from the deficient activity of human alpha-N-acetylgalactosaminidase (E.C....Full Text Available

1994-08-01

295

Stromal-Derived Factor-1 (CXCL12) Regulates Laminar Position of Cajal-Retzius Cells in Normal and Dysplastic Brains  

UK PubMed Central (United Kingdom)

Normal brain development requires a series of highly complex and interrelated steps. This process presents many opportunities for errors to occur, which could result in developmental defects...Full Text Available

2006-09-13

296

Some problems about the spline curve fitting method  

International Nuclear Information System (INIS)

The parameters including knot numbers, knot positions and the weights associated with the systematic errors in the cubic spline curve fitting method were discussed. The conditions of using fitting criterion were given as well.

297

Site Error There's a problem with ... - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Bending moments recorded by sensors on the aluminum tube. ... the escape rocket motor, tests also were made with the escape tower and rocket .... Incoming photographic data will be electronically converted and processed ...

298

Separate Non-Homomorphic Checking Codes for Binary Addition.  

Science.gov (United States)

In this paper, necessary and sufficient conditions for successful detection of errors in a binary adder by any separate code are developed. The author demonstrates the existence of separate checking codes for addition modulo (2 sup n) ( n > or = 4) and mo...

1972-01-01

299

Revised neutron dosimetry results for the MOTA-2A experiment in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.

1994-09-01

300

Refractive outcome following diode laser versus cryotherapy for eyes with retinopathy of prematurity.  

UK PubMed Central (United Kingdom)

The refractive error in 15 eyes with threshold retinopathy of prematurity treated with diode laser photocoagulation was compared with 25 eyes with the same disease severity treated by cryotherapy. Myopia...Full Text Available

1994-08-01

301

Problems for clinical judgement: 2. Obtaining a reliable past medical history  

UK PubMed Central (United Kingdom)

ORDINARY HUMAN REASONING MAY LEAD PATIENTS to provide an unreliable history of past experiences because of errors in comprehension, recall, evaluation and expression. Comprehension of a question may...Full Text Available

2001-03-20

302

Power of grammatical evolution neural networks to detect gene-gene interactions in the presence of error  

UK PubMed Central (United Kingdom)

BackgroundWith the advent of increasingly efficient means to obtain genetic information, a great insurgence of data has resulted, leading to the need for methods for analyzing this...Full Text Available

303

Modeling of electricity consumption in the Asian gaming and tourism center - Macao SAR, People's Republic of China  

Energy Technology Data Exchange (ETDEWEB)

The use of electricity is indispensable to modern life. As Macao Special Administrative Region becomes a gaming and tourism center in Asia, modeling the consumption of electricity is critical to Macao's economic development. The purposes of this paper are to conduct an extensive literature review on modeling of electricity consumption, and to identify key climatic, demographic, economic and/or industrial factors that may affect the electricity consumption of a country/city. It was identified that the five factors, namely temperature, population, the number of tourists, hotel room occupancy and days per month, could be used to characterize Macao's monthly electricity consumption. Three selected approaches including multiple regression, artificial neural network (ANN) and wavelet ANN were used to derive mathematical models of the electricity consumption. The accuracy of these models was assessed by using the mean squared error (MSE), the mean ...

2008-05-15

304

Meiotic recombination in the beta globin gene cluster causing an error in prenatal diagnosis of beta thalassaemia.  

UK PubMed Central (United Kingdom)

In the course of a prenatal diagnosis for beta thalassaemia by linkage analysis of restriction fragment length polymorphisms, a homozygous beta thalassaemia fetus was misdiagnosed as beta thalassaemia...Full Text Available

1988-05-01

305

Is there life after Rothschild  

Energy Technology Data Exchange (ETDEWEB)

The article reviews the Rothschild First Interim Report on the future of the British Coal Industry and British Coal Corporation. The report incorporates work undertaken by the Joint Working Groups set up with British Coal. The article points out various errors in the report and criticizes its conclusions.

1991-11-01

306

GRB 090510 - GCN - NASA  

Science.gov (United States)

May 10, 2009 ... The estimated magnitude is 18.95 with a 1-sigma error of about 0.17. ... The points of contact for this burst is Masanori Ohno .... 80 seconds after the BAT trigger with a settling exposure in the UVOT v filter. ...

307

Frequency of Aneuploidy Related to Age in Porcine Oocytes  

UK PubMed Central (United Kingdom)

It is generally accepted that mammalian oocytes are frequently suffering from chromosome segregation errors during meiosis I, which have severe consequences, including pregnancy loss, developmental...Full Text Available

308

Decoding of Matrix-Product Codes  

CERN Document Server

We propose a decoding algorithm for the $(u\\mid u+v)$-construction that decodes up to half of the minimum distance of the linear code. We extend this algorithm for a class of matrix-product codes in two different ways. In some cases, one can decode beyond the error correction capability of the code.

2011-01-01

309

DISPERSION TOLERANCE CALCULATION FOR NSLS-II.  

Energy Technology Data Exchange (ETDEWEB)

In this paper we discuss the effect on the emittance of the residual dispersion in the insertion devices. The dispersion in the straights could be generated by the lattice error, trim dipole, and insertion device. The effect on the emittance is examined, and the dispersion tolerances are given for the NSLS-11.

2007-06-25

310

Characterization of the binding sites for dicarboxylic acids on bovine serum albumin.  

UK PubMed Central (United Kingdom)

Dicarboxylic acids are prominent features of several diseases, including Reye's syndrome and inborn errors of mitochondrial and peroxisomal fatty acid oxidation. Moreover, dicarboxylic acids are potentially...Full Text Available

1991-06-15

311

CHANDFS2MS - Chandra Deep Field South 2 ... - HEASARC - NASA  

Science.gov (United States)

This table contains point-source catalogs for the ~2 Ms exposure of the Chandra Deep ... Source positions are determined using centroid and matched-filter techniques; .... The 1-sigma upper statistical error (Gehrels 1986, ApJ, 303, ...

312

Analysis of the astray/robo2 zebrafish mutant reveals that degenerating tracts do not provide strong guidance cues for regenerating optic axons  

UK PubMed Central (United Kingdom)

During formation of the optic projection in astray/robo2 mutant zebrafish, optic axons exhibit rostro-caudal pathfinding errors, ectopic midline crossing and...Full Text Available

2010-10-13

313

Americium and curium total half-lives and for the spontaneous fission branch  

Energy Technology Data Exchange (ETDEWEB)

The long-lived nuclides of the americium and curium elements are of interest for their use in certain safeguard applications and for nuclear reactor burnup studies in waste management. Recommended values are presented for /sup 241,242m,243/Am, and for /sup 242,243,244,245,246,247,248,250/Cm. These values result from a consistent evaluation of all these half-lives. These preliminary estimates were presented earlier. The uncertainties are provided at the 95% confidence limit for each of the recommended values. It will be noted that many of the recommended errors considerably exceed errors quoted by individual authors in their publication, by up to an order of magnitude, e.g. the total half-life of /sup 242,246,248/Cm and the spontaneous fission half-life of /sup 244/Cm. These preliminary estimates for the half-lives were given previously. Efforts continue to reevaluate the various experiments to better gauge the systematic ...

1985-01-01

314

AVISO and PODAAC User Handbook IGDR and GDR Jason Products - NASA  

Science.gov (United States)

An ascending node occurs when the subsatellite point crosses the earth's equator going from .... 11dB sigma-naught. This error budget includes the altimeter noise, ...... it is also recommended to filter the data as follows to ...

315

'TT ( \\\\ b - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Inertial navigation error propagation. 153. 100. --. 8. GN-5. Hypersonic entry guidance techniques. 150. 100. 0.8. 9. FM-13. Ablation effects on hypersonic ...

316

Robust distributed model predictive control: A review and recent developments  

British Library Electronic Table of Contents (United Kingdom)

Abstract This study presents a review of distributed model predictive control (DMPC) strategies followed by recent studies conducted by the authors on the robustness of these strategies to model errors and a summary of future challenges in this area. The review identifies three key challenges for the successful application of DMPC: (i) the selection of optimal control structure for DMPC; (ii) the choice of a suitable coordination strategy among the controllers; and (iii) the robustness of DMPC strategies to model errors. Then, the study summarises recent developments related to the robustness of unconstrained and constrained DMPC algorithms. For the unconstrained case, a methodology that is based on the calculation of a performance index is proposed to balance the trade-off between perform...

2011-01-01

317

Measurement error modeling and nutritional epidemiology association analyses  

British Library Electronic Table of Contents (United Kingdom)

Abstract This article summarizes the results of a Nutrient Biomarker Study in the Women's Health Initiative, and its application to studies of the association between energy and protein consumption and the risk of major cancers and cardiovascular diseases. The presentation emphasizes measurement error modeling and related data analysis methods, since addressing measurement issues appears to be central to these topics and to progress in nutritional epidemiology more generally. The manner in which body mass index is modeled in disease association analysis is particularly challenging, since it could serve as a mediator or as a confounder of the association, and at the same time contributes valuably to energy and protein consumption assessment. A hazard ratio parameter estimation procedure tha...

2011-01-01

318

MIMO APP Receiver Processing with Performance-Determined Complexity  

CERN Document Server

Typical receiver processing, targeting always the best achievable bit error rate performance, can result in a waste of resources, especially, when the transmission conditions are such that the best performance is orders of magnitude better than the required. In this work, a processing framework is proposed which allows adjusting the processing requirements to the transmission conditions and the required bit error rate. It applies a-posteriori probability receivers operating over multiple-input multiple-output channels. It is demonstrated that significant complexity savings can be achieved both at the soft, sphere-decoder based detector and the channel decoder with only minor modifications.

2010-01-01

319

Fitting the fully coupled ORM for the Fermilab Booster  

Energy Technology Data Exchange (ETDEWEB)

The orbit response matrix (ORM) method [1] is applied to model the Fermilab Booster with parameters such as the BPM gains and rolls, and parameters in the lattice model, including the gradient errors and magnets rolls. We found that the gradients and rolls of the adjacent combined-function magnets were deeply correlated, preventing full determination of the model parameters. Suitable constraints of the parameters were introduced to guarantee an unique, equivalent solution. Simulations show that such solution preserves proper combinations of the adjacent parameters. The result shows that the gradient errors of combined-function magnets are within design limits.

2005-05-01

320

Error evaluation of the linearized equation of servo valve in hydraulic control systems  

International Nuclear Information System (INIS)

In the procedure of the hydraulic control system analysis, a linearized approximate equation described by the first order term of Taylor's series has been widely used. Such a linearized equation is effective just near the operating point. In this study, the authors estimate computational errors in the process of applying the existing linearized equation stated above. For evaluating the computational accuracy in practical applications of the linearized equations, dynamic behaviors of hydraulic control systems are investigated through simulations with several kinds of representative hydraulic systems and the linearized equations suggested in this study.

2001-11-01

321

Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles  

International Nuclear Information System (INIS)

Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes

322

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

323

Alignment accuracy of focused ion beam implantation  

Energy Technology Data Exchange (ETDEWEB)

The theoretical alignment limit for focused ion beam (FIB) implantation was deduced from the calculated resolution for the detection of an alignment mark. The alignment resolution varies with the signal to noise ratio and there is an optimum current which gives the best resolution. The alignment resolution epsilon/sub sigma/ is approximately 0.006 ..mu..m for a 160 keV Si/sup ++/ beam from our FIB implanter. The measured alignment error is approximately 0.06 ..mu..m and the main reason of this discrepancy is vibration. The ultimate limit on the alignment error can be reached through improvements in the implanter system.

1987-06-01

324

VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:  

Science.gov (United States)

0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...

325

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

326

Spectral D line of Na-like multicharged ions and phenomenological inclusion of the Lamb shift in the many-electron systems  

International Nuclear Information System (INIS)

Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.

327

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

328

Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...

1995-05-01

329

Regulatory experience on safety system instrument uncertainty of Wolsong units  

International Nuclear Information System (INIS)

This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...

2001-05-01

330

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

331

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

332

Mission Science Calibration and Validation Plan - SMAP  

Science.gov (United States)

Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...

333

Influencing factors on ESR dose assessment in irradiated chicken legs  

Energy Technology Data Exchange (ETDEWEB)

Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).

1996-12-31

334

Ground water modelling in artificial recharge projects  

International Nuclear Information System (INIS)

Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.

1991-05-09

335

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

336

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

337

Colorimetric porous indicator of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.

1986-03-01

338

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

339

Applications of Auger spectroscopy and ESCA to the study of thin films formed on metals  

International Nuclear Information System (INIS)

Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.

1979-05-23

340

An ultrasonic goniometer for surface stress measurement  

Science.gov (United States)

An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.

1978-09-01

341

An instrument for measuring spatial and time characteristics of sea agitation in coastal zones  

Energy Technology Data Exchange (ETDEWEB)

Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.

1981-01-01

342

Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium  

International Nuclear Information System (INIS)

An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and the TMS Pencil Beam ...

2004-10-01

343

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for ...

2009-08-01

344

Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantom  

International Nuclear Information System (INIS)

With the advent of intensity-modulated radiation therapy (IMRT), the inclusion of heterogeneity corrections is further complicated by the conformal delivery of many small beams forming steep dose gradients. Radiation treatment planning has evolved to take into account even small changes in tissue density so that the dose to tumor can be further optimized. However, different treatment planning systems incorporate different heterogeneity correction algorithms, and it is unclear whether any of these algorithms are superior to others in terms of accurately predicting delivered radiation doses relative to measurement in a clinical setting. The purpose of this study was to determine the accuracy of heterogeneity dose calculations from two widely used IMRT treatment planning systems (Pinnacle and Corvus) against measurement. These two systems handle heterogeneity dose corrections by means of a collapsed-cone convolution superposition algorithm and a finite-size pencil-beam algorithm with ...

2007-05-01

345

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

346

Tracheal cross-sectional area in children: CT determination  

Energy Technology Data Exchange (ETDEWEB)

A computer method that calculates tracheal cross-sectional area by compensating for partial volume averaging was developed and validated in a study with phantoms. The program was then used to determine the tracheal cross-sectional area of 30 normal children who ranged in age from four months to 18 years. CT-derived cross sections were correlated with age, height, weight, and body-surface area, and they were compared with findings of published clinical and post-mortem studies. CT cross-sectional areas ranged from 20 to 275 mm/sup 2/, varied by as much as 22% at the three different tracheal levels studied, and appeared to correlate most closely with body height. CT-derived tracheal cross-sectional areas are quite similar to those in published reports of postmortem and clinical studies. Measurements of tracheal cross section by CT may prove useful in quantitating tracheal compromise by intrinsic or extrinsic causes.

1983-10-01

347

Total skin electron beam therapy in mycosis fungoides. Evaluation of a technique for deceleration of electron beam energy and clinical study  

Energy Technology Data Exchange (ETDEWEB)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.

1988-08-01

348

Total skin electron beam therapy in mycosis fungoides  

International Nuclear Information System (INIS)

The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeV electron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).

349

The effect of patient positioning aids on PET quantification in PET/MR imaging  

British Library Electronic Table of Contents (United Kingdom)

Objectives Clinical PET/MR requires the use of patient positioning aids to immobilize and support patients for the duration of the combined examination. Ancillary immobilization devices contribute to overall attenuation of the PET signal, but are not detected with conventional MR sequences and, hence, are ignored in standard MR-based attenuation correction (MR-AC). We report on the quantitative effect of not accounting for the attenuation of patient positioning aids in combined PET/MR imaging. Methods We used phantom and patient data acquired with positioning aids on a PET/CT scanner (Biograph 16, HI-REZ) to mimic PET/MR imaging conditions. Reference CT-based attenuation maps were generated from measured (original) CT transmission images (origCT-AC). We also created MR-like attenuation map...

2011-01-01

350

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is a further alternative with respect to ...

1981-01-01

351

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)  

International Nuclear Information System (INIS)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs - red bone marrow, lung, thyroid gland and female breast - and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated. (orig.).

1986-01-01

352

Sex Differences in Pain and Psychological Functioning in Persons With Limb Loss  

British Library Electronic Table of Contents (United Kingdom)

Sex differences in pain are frequently reported in the literature. However, less is known about possible sex differences in the experience of pain secondary to a disability. The current study explored these issues in persons with limb loss (n = 335, 72% men) who were recruited as part of a postal survey. Participants provided ratings of phantom limb pain (PLP), residual limb pain (RLP), and general pain intensity. Participants also completed measures of pain-related interference, catastrophizing, coping, and beliefs. Results indicated that a greater proportion of males than females (86% vs 77%, respectively) reported the presence of PLP; however, this difference was no longer prominent when cause of limb loss was controlled. No sex differences were found in the presence of RLP, or in avera...

2010-01-01

353

Radioexposure of children in cranial examinations with new-generation CT equipment  

Energy Technology Data Exchange (ETDEWEB)

Using phantoms of children simulating a child of 6 months of age and another one aged 6 years, the authors measured the amount of radioexposure of the lens of the eye, the thyroid and of the gonads. The two computer tomographs Somatom SF and Tomoscan 300 under examination, produced radiodoses of comparable magnitudes. Both devices allow additional examination techniques of particularly high economy. It was found that in cranial CT the exposure of the lens to radiation is generally below 1 R if the orbitae are not situated in the plane of section. If a distance of 2-3 cm is maintained from the orbitae, the dose remains below 0.5 R. Protecting the gonads is meaningful in a 6-year-old boy, whereas covering-up of the thyroid reduced the dose only slightly.

1983-04-01

354

Radiation exposure to patients during hepatic interventional procedure  

International Nuclear Information System (INIS)

Objective: To investigate the X-ray radiation dose patients dealt with the hepatic intervention. Methods: Thermoluminescence and tissue-equivalent anthropomorphic phantom were used to measure the X-ray radiation dose in patients dealt with the hepatic intervention in 85 patients. Results: The peak skin dose in the patients who accepted hepatic intervention was from 179.95 to 1759.00 mGy, effective dose approached 29.22 mSv (male), 29.27 mSv (female). Conclusion: Hepatic intervention is now regarded as an important therapeutic method for liver cancer. However, the patients were exposed to too much X-ray radiation during interventional procedures. Some more effective protection should be taken to decrease the X-ray radiation dose accepted by patients. (authors)

2005-05-01

355

Preamputation Pain and Acute Pain Predict Chronic Pain After Lower Extremity Amputation  

British Library Electronic Table of Contents (United Kingdom)

Although previous research suggests that preamputation pain is a risk factor for pain after amputation, little is known about the association between acute postsurgical pain and chronic amputation-related pain. The current prospective study examined the associations of preamputation pain and acute postamputation pain with chronic amputation-related pain. The sample consisted of patients with lower limb amputation (N = 57) who provided both preamputation and postamputation data during a 2-year study period. Preamputation pain intensity and duration were assessed before amputation; acute phantom limb pain (PLP) and residual limb pain (RLP) intensity were assessed on postsurgical days 4 and 5. Acute PLP intensity was the only significant independent predictor of chronic PLP intensity at 6 and...

2007-01-01

356

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

357

Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine  

International Nuclear Information System (INIS)

The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)

358

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue and has potential ...

2008-05-07

359

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

Energy Technology Data Exchange (ETDEWEB)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-08-01

360

Organ doses received by atomic bomb survivors during radiological examinations at the Radiation Effects Research Foundation  

International Nuclear Information System (INIS)

When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).

1991-01-01

361

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

362

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

Energy Technology Data Exchange (ETDEWEB)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

1992-11-01

363

Efficiency of a lead-containing tie for radiation protection of the thyroid gland  

International Nuclear Information System (INIS)

During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).

364

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

365

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

366

Affective Distress and Amputation-Related Pain Among Older Men with Long-Term, Traumatic Limb Amputations  

British Library Electronic Table of Contents (United Kingdom)

Psychological distress and postamputation pain were investigated in a sample of 582 males with long-term limb amputations (mean time since amputation 639.3 months, standard deviation 166.1; range 240-784 months). Prevalence of significant depressive symptoms (Hospital Anxiety and Depression Scale [HADS]-D score?8) was 32.0%, and 34.0% of respondents met the screening criterion for clinical anxiety (HADS-A score?8). Nearly one quarter (24.6%) of respondents reported significant post-traumatic psychological stress symptoms (Impact of Event Scale scores?35). In total, 87.8% experienced either phantom or residual limb pain. Affective distress scores differed according to the respondents' type of pain experience. Respondents who experienced residual limb pain reported significantly hig...

2006-01-01

367

A novel method for quantifying scanner instability in fMRI  

British Library Electronic Table of Contents (United Kingdom)

Abstract A method was developed to quantify the effect of scanner instability on functional MRI data by comparing the instability noise to endogenous noise present when scanning a human. The instability noise was computed from agar phantom data collected with two flip angles, allowing for a separation of the instability from the background noise. This method was used on human data collected at four 3 T scanners, allowing the physiological noise level to be extracted from the data. In a -well-operating- scanner, the instability noise is generally less than 10% of physiological noise in white matter and only about 2% of physiological noise in cortex. This indicates that instability in a well-operating scanner adds very little noise to functional MRI results. This new method allows researcher...

2011-01-01

368

Energy optimal synthesis of perodic motions in multibody systems; Energieoptimale Synthese periodischer Arbeitsbewegungen in Mehrkoerpersystemen  

Energy Technology Data Exchange (ETDEWEB)

In robotics inverse dynamics is a standard control concept for highly nonlinear multibody systems. It is shown, however, that inverse dynamics results in a high energy demand. Therefore, linear energy efficient state feedback controllers are designed in a way that a performance index representing the energy consumption is minimized. At the same time inequality constraints such as control error and limited input variables have to be met. For the control design an analytical solution by pole placement is presented as well as a numerical controller optimization. This control design includes small motions in the neighborhood of the operating point. Then, linear controllers are tested with respect to control error and energy consumption when undergoing large displacement motion. It is shown that linear state feedback can only save energy if large control errors are accepted. Therefore, nonlinear systems are optimized as a whole ...

2006-07-01

369

Sensitivity analysis and development of calibration methodology for near-surface hydrogeology model of Laxemar  

Energy Technology Data Exchange (ETDEWEB)

This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...

2007-11-15

370

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...

2001-06-17

371

Using a photon phase-space source for convolution/superposition dose calculations in radiation therapy  

International Nuclear Information System (INIS)

For a given linac design, the dosimetric characteristics of a photon beam are determined uniquely by the energy and radial distributions of the electron beam striking the x-ray target. However, in the usual commissioning of a beam from measured data, a large number of variables can be independently tuned, making it difficult to derive a unique and self-consistent beam model. For example, the measured dosimetric penumbra in water may be attributed in various proportions to the lateral secondary electron range, the focal spot size and the transmission through the tips of a non-divergent collimator; the head-scatter component in the tails of the transverse profiles may not be easy to resolve from phantom scatter and head leakage; and the head-scatter tails corresponding to a certain extra-focal source model may not agree self-consistently with in-air output factors measured on the central axis. To reduce the number of adjustable variables in beam modelling, we replace ...

2005-09-07

372

Spectral sensitivity study of dose distributions for a commercial convolution/superposition algorithm  

International Nuclear Information System (INIS)

The focus of this study is to validate whether the sensitivity of dose distribution following the interface of different media can be used to distinguish between small variations of photon energy spectra in the context of the convolution/superposition algorithm in the polyenergetic implementation (Philips Pinnacle"3, ADAC Laboratories, Milpitas, CA). Calculations were performed in homogeneous water and heterogeneous lung/water phantoms. Spectra were generated, in which the weights of the low-, medium- and high-energy components were adjusted sequentially. The heterogeneity correction factor CF_l_u_n_g, the D_2_0/D_1_0 ratio for homogeneous water and logarithmic derivative in buildup region LD_b_u_i_l_d_u_p were assessed for their relative ability to discriminate between different spectra for various field sizes. In accordance with another study (Charland et al 2004), the superior discrimination ability of the CF_l_u_n_g and LD_b_u_i_l_d_u_p tests over the ...

2004-09-21

373

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-08-01

374

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided into four parts and displayed four images as a subsidiary diagnosis. The upper two images were displayed ...

1989-01-01

375

Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues  

Science.gov (United States)

Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a function of depth in tissue phantoms with a range of relevant optical properties. The ...

2011-02-01

376

Feasibility of delivering grid therapy using a multileaf collimator  

International Nuclear Information System (INIS)

The feasibility of using a multileaf collimator (MLC) for grid therapy is demonstrated in this study. Grids with the projected field openings of 10 mmx10 mm and 5 mmx5 mm were created using multiple MLC-shaped fields. The deposited doses were measured with films at different depths in a solid water phantom and compared to those of Cerrobend grid collimators of similar hole sizes and hole separations. At the depth of maximum dose (d_m_a_x), the valley-to-peak dose ratios of the MLC grids were found to be about 11% and 19% for the respective 10 mmx10 mm and 5 mmx5 mm grid openings, and those of the corresponding grid blocks were about 15% and 20%. To quantify the dose contributed by transmission in the blocked areas due to the limited leaf thickness, Monte Carlo simulations (based on convolution/superposition method) were performed to calculate the doses in the solid water phantom using an ideal MLC with no leakage and perfect divergence in both ...

2006-01-01

377

Dosimetric evaluation of multi-pattern spatially fractionated radiation therapy using a multi-leaf collimator and collapsed cone convolution superposition dose calculation algorithm  

International Nuclear Information System (INIS)

Purpose: In this paper, we present an alternative to the originally proposed technique for the delivery of spatially fractionated radiation therapy (GRID) using multi-leaf collimator (MLC) shaped fields. We employ the MLC to deliver various pattern GRID treatments to large solid tumors and dosimetrically characterize the GRID fields. Methods and materials: The GRID fields were created with different open to blocked area ratios and with variable separation between the openings using a MLC. GRID designs were introduced into the Pinnacle"3 treatment planning system, and the dose was calculated in a water phantom. Ionization chamber and film measurements using both Kodak EDR2 and Gafchromic EBT film were performed in a SolidWater phantom to determine the relative output of each GRID design as well as its spatial dosimetric characteristics. Results: Agreement within 5.0% was observed between the Pinnacle"3 predicted dose distributions and the ...

2009-10-01

378

Digital subtraction angiography (DSA) using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

A vessel phantom suitable for evaluation of spatial and contrast resolution of FCRDSA (Fuji Computed Radiography, digital subtraction angiography) has been developed and used for determining resolution. The effects of iodine concentration, low dose exposure, and acryl thickness on the resolution were evaluated in FCRDSA, and FCRDSA images were compared with film substraction with use of this phantom. It has been proven that limitation of resolution of FCRDSA was 5 % 1 mm and about 1/4 dose exposure compared with conventional film exposure was clinically acceptable. Dye dilution method was useful to determine a program of IVDSA with imaging plate. It has been proven that time to appearance and time to peak of time-concentration curve of dye dilution method closely correlate to time to appropriate image of DSA in the neck, the chest, and the abdomen. 106 cases of IVDSA and 130 cases of IADSA using FCR in Tohoku University Hospital from January ...

1984-12-01

379

Accuracy of the convolution/superposition dose calculation algorithm at the condition of electron disequilibrium  

International Nuclear Information System (INIS)

Using Monte Carlo simulation and the convolution/superposition algorithm, this work examines percent depth dose curves of the central axis in an acrylic phantom (20x20x20 cm"3) with variously sized air cavities (20x20x1.0, 20x20x2.0, 20x20x3.0, 20x20x4.0 and 20x20x4.95 cm"3 for study of longitudinal electron disequilibrium (ED) and 3.6x3.6x4.95, 4.5x4.5x4.95, 5.4x5.4x4.95 and 20x20x4.95 cm"3 for study of lateral ED). Radiochromic film samples are also measured to verify the Monte Carlo results. The Monte Carlo simulation is performed using OMEGA/BEAM and DOSXYZ codes, and the convolution/superposition calculation relies on an ADAC commercial treatment planning system. Underestimating the dose kernel expansion leads to overestimating the dose of what was found in the air cavity of ED using the convolution/superposition algorithm. Consequently, the dose in the rebuild-up region is influenced. The influenced region is on the acrylic phantom ...

2002-12-01

380

A cooled water-irrigated intraesophageal balloon to prevent thermal injury during cardiac ablation: experimental study based on an agar phantom  

Energy Technology Data Exchange (ETDEWEB)

A great deal of current research is directed to finding a way to minimize thermal injury in the esophagus during radiofrequency catheter ablation of the atrium. A recent clinical study employing a cooling intraesophageal balloon reported a reduction of the temperature in the esophageal lumen. However, it could not be determined whether the deeper muscular layer of the esophagus was cooled enough to prevent injury. We built a model based on an agar phantom in order to experimentally study the thermal behavior of this balloon by measuring the temperature not only on the balloon, but also at a hypothetical point between the esophageal lumen and myocardium (2 mm distant). Controlled temperature (55 {sup 0}C) ablations were conducted for 120 s. The results showed that (1) the cooling balloon provides a reduction in the final temperature reached, both on the balloon surface and at a distance of 2 mm; (2) coolant temperature has a significant effect on the temperature ...

2008-02-21

381

Topology of modified helical gears and Tooth Contact Analysis (TCA) program  

Science.gov (United States)

The contents of this report covers: (1) development of optimal geometries for crowned helical gears; (2) a method for their generation; (3) tooth contact analysis (TCA) computer programs for the analysis of meshing and bearing contact of the crowned helical gears; and (4) modelling and simulation of gear shaft deflection. The developed method for synthesis was used to determine the optimal geometry for a crowned helical pinion surface and was directed to localize the bearing contact and guarantee favorable shape and a low level of transmission errors. Two new methods for generation of the crowned helical pinion surface are proposed. One is based on the application of a tool with a surface of revolution that slightly deviates from a regular cone surface. The tool can be used as a grinding wheel or as a shaver. The other is based on a crowning pinion tooth surface with predesigned transmission errors. The pinion tooth surface can be generated by ...

1989-01-01

382

Performance evaluation for ML sequence detection in ISI channels with Gauss Markov Noise  

CERN Document Server

Inter-symbol interference (ISI) channels with data dependent Gauss Markov noise have been used to model read channels in magnetic recording and other data storage systems. The Viterbi algorithm can be adapted for performing maximum likelihood sequence detection in such channels. However, the problem of finding an analytical upper bound on the bit error rate of the Viterbi detector in this case has not been fully investigated. Current techniques rely on an exhaustive enumeration of short error events and determine the BER using a union bound. In this work, we consider a subset of the class of ISI channels with data dependent Gauss-Markov noise. We derive an upper bound on the pairwise error probability (PEP) between the transmitted bit sequence and the decoded bit sequence that can be expressed as a product of functions depending on current and previous states in the (incorrect) decoded sequence and the (correct) transmitted ...

2010-01-01

383

Optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 with an optimized cost perspective  

Energy Technology Data Exchange (ETDEWEB)

In this work, a model for determining the optimal inspection and replacement periods of the safety system in Wolsung Nuclear Power Plant Unit 1 is developed, which is to minimize economic loss caused by inadvertent trip and the system failure. This model uses cost benefit analysis method and the part for optimal inspection period considers the human error. The model is based on three factors as follows: (i) The cumulative failure distribution function of the safety system, (ii) The probability that the safety system does not operate due to failure of the system or human error when the safety system is needed at an emergency condition and (iii) The average probability that the reactor is tripped due to the failure of system components or human error. The model then is applied to evaluate the safety system in Wolsung Nuclear Power Plant Unit 1. The optimal replacement periods which are calculated with proposed model differ ...

1996-01-01

384

Optimal alignment of mirror based pentaprisms for scanning deflectometric devices  

Science.gov (United States)

In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction ...

2011-03-04

385

On the application of Allan variance method for Ring Laser Gyro performance characterization  

Energy Technology Data Exchange (ETDEWEB)

This report describes the method of Allan variance and its application to the characterization of a Ring Laser Gyro`s (RLG) performance. Allan variance, a time domain analysis technique, is an accepted IEEE standard for gyro specifications. The method was initially developed by David Allan of the National Bureau of Standards to quantify the error statistics of a Cesium beam frequency standard employed as the US Frequency Standards in 1960`s. The method can, in general, be applied to analyze the error characteristics of any precision measurement instrument. The key attribute of the method is that it allows for a finer, easier characterization and identification of error sources and their contribution to the overall noise statistics. This report presents an overview of the method, explains the relationship between Allan variance and power spectral density distribution of underlying noise sources, describes the batch and ...

1993-10-15

386

Malignant pulmonary lesion. Possible causes of CT misdiagnosis; Possibilita' di falsi negativi nella diagnosi delle neoplasie polmonari con Tomografia Computerzzata  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work is to describe the radiological appearance of overlooked malignant pulmonary lesions at CT and to analyze the reasons of misdiagnosis. Ten patient with pulmonary lesion (PML) overlooked at forst CT examination were selected among patients with lung cancer. Endobronchial location of the tumors and their small size were the most frequent causes of misdiagnosis of PML at chest CT in the series. However, a systematic evaluation of CT scans can reduce the percentage of missed lesions. [Italian] Scopo del presente lavoro e' di descrivere le caratteristiche radiologiche delle lesioni polmonari maligne non identificate con la Tomografia Computerizzata (TC) e definire le possibili cause di errore. Sono stati esaminato 10 pazienti con tumore polmonare. Le sedi endobronchiale e centrale nonche' le piccole dimensioni delle lesioni polmonari maligne rappresentano le cause piu' frequenti di errore ...

1999-06-01

387

Experimental demonstration of phase-remapping attack in a practical quantum key distribution system  

International Nuclear Information System (INIS)

Quantum key distribution (QKD) can, in principle, provide unconditional security based on the fundamental laws of physics. Unfortunately, a practical QKD system may contain overlooked imperfections and may thus violate some of the assumptions in the security proofs of QKD. It is important to explore these assumptions. One key assumption is that the sender (Alice) can prepare the required quantum states without errors. However, such an assumption may be violated in a practical QKD system. In this paper, we perform a proof-of-principle experiment to demonstrate a technically feasible 'intercept- and-resend' attack that exploits such a security loophole in a commercial 'plug and play' QKD system. The resulting quantum bit error rate is 19.7%, which is substantially lower than the well-known 25% error rate for an intercept-and-resend attack in BB84. The attack we utilize is the phase-remapping attack (Fung et al 2007 Phys. Rev. ...

2010-11-01

388

Efficient calculation of the worst-case error and (fast) component-by-component construction of higher order polynomial lattice rules  

CERN Document Server

We show how to obtain a fast component-by-component construction algorithm for higher order polynomial lattice rules. Such rules are useful for multivariate quadrature of high-dimensional smooth functions over the unit cube as they achieve the near optimal order of convergence. The main problem addressed in this paper is to find an efficient way of computing the worst-case error. A general algorithm is presented and explicit expressions for base~2 are given. To obtain an efficient component-by-component construction algorithm we exploit the structure of the underlying cyclic group. We compare our new higher order multivariate quadrature rules to existing quadrature rules based on higher order digital nets by computing their worst-case error. These numerical results show that the higher order polynomial lattice rules improve upon the known constructions of quasi-Monte Carlo rules based on higher order digital nets.

2011-01-01

389

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements done with an atmosphere ...

1981-10-01

390

A comparison of truncated total least squares with Tikhonov regularization in imaging by ultrasound inverse scattering  

International Nuclear Information System (INIS)

For good image quality using ultrasound inverse scattering, one alternately solves the well-posed forward scattering equation for an estimated total field and the ill-posed inverse scattering equation for the desired object property function. In estimating the total field, error or noise contaminates the coefficients of both matrix and data of the inverse scattering equation. Previous work on ill-posed inverse ultrasonic scattering commonly used Tikhonov regularization, which considers error only in the data. The solution so obtained is not precise enough to reconstruct the quantitative internal structure of a large or high-contrast object. This paper adopts the truncated total least squares method, simultaneously considering error and noise on both sides of the inverse scattering equation, and compares it with the classical Tikhonov regularization. We show that it can substantially improve reconstruction fit and image ...

2003-08-07

391

West Siberian basin hydrogeology - regional framework for contaminant migration from injected wastes  

Energy Technology Data Exchange (ETDEWEB)

Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...

1994-05-01

392

Using calibrated engineering models to predict energy savings in large-scale geothermal heat pump projects  

Energy Technology Data Exchange (ETDEWEB)

Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...

1998-10-01

393

Using Calibrated Engineering Models To Predict Energy Savings In Large-Scale Geothermal Heat Pump Projects  

Energy Technology Data Exchange (ETDEWEB)

Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...

1998-01-01

394

The design and performance of a capacitance sensor for two-phase flow concentration measurements in a square duct  

Energy Technology Data Exchange (ETDEWEB)

The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...

1995-12-31

395

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...

2009-09-14

396

Simultaneous determination of dorzolamide HCL and timolol maleate in eye drops by two different spectroscopic methods.  

Science.gov (United States)

Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...

2002-04-15

397

Quantification of the local glucose utilization and local blood flow in the heart of the awake rat using the /sup 14/C-2-deoxyglucose and /sup 14/C-iodoantipyrine methods  

Science.gov (United States)

Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.

1986-03-05

398

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well ...

1977-11-01

399

Life Under Your Feet: An End-to-End Soil Ecology Sensor Network, Database, Web Server, and Analysis Service  

CERN Document Server

Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...

2007-01-01

400

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-07-01

401

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...

2007-05-10

402

Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR  

Science.gov (United States)

The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...

1978-04-01

403

Determination of binary mixtures of analgesic and spasmolytic drugs in pure and dosage forms by derivative spectrophotometry.  

Science.gov (United States)

Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...

2003-10-15

404

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers  

Energy Technology Data Exchange (ETDEWEB)

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...

2008-01-16

405

BINERY PSEUDO-RANDOM GRATING AS A STANDARD TEST SURFACE FOR MEASUREMENT OF MODULATION TRANSFER FUNCTION OF INTERFEROMETRIC MICROSCOPES.  

Energy Technology Data Exchange (ETDEWEB)

The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...

2007-08-01

406

Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma  

Energy Technology Data Exchange (ETDEWEB)

In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...

2009-07-15

407

Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma  

International Nuclear Information System (INIS)

In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...

2009-07-01

408

Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device  

Energy Technology Data Exchange (ETDEWEB)

We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment less than 5 %.

2005-02-15

409

Analysis and calibration of transient enhanced diffusion for an indium impurity in a nanoscale semiconductor device  

International Nuclear Information System (INIS)

We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than 5 %.

2005-02-01

410

Widely Linear Kalman Filtering  

CERN Document Server

For a zero mean, proper, complex random vector x, the Hermitian covariance ExxH is a complete second-order characterization. However, if the vector x is improper, it is correlated with its complex conjugate, meaning ExxT = 0. This improper or complementary covariance must be accounted for in a complete second-order characterization. The improper covariance has been exploited for widely linear (WL) Wiener filters and WL minimum mean squared error (MMSE) estimators, and the improvement in performance of the WLMMSE estimator over the LMMSE estimator has been quantified. In this paper we consider the design of the widely linear Kalman filter (WLKF). We analyze the WLKF, extended WLKF, and unscented WLKF. The key idea of this paper is to modify the error covariance matrices and the construction of effective sigma points in the WLKF in a systematic way that exploits the Hermitian and complementary covariance of improper states and noises.

2011-01-01

411

Unraveling duality violations in hadronic tau decays  

Energy Technology Data Exchange (ETDEWEB)

There are some indications from recent determinations of the strong coupling constant alpha_s and the gluon condensate that the Operator Product Expansion may not be accurate enough to describe non-perturbative effects in hadronic tau decays. This breakdown of the Operator Product Expansion is usually referred to as being due to"Duality Violations." With the help of a physically motivated model, we investigate these duality violations. Based on this model, we argue how they may introduce a non-negligible systematic error in the current analysis, which employs finite-energy sum rules with pinched weights. In particular, this systematic effect might affect the precision determination of alpha_s from tau decays. With a view to a possible future application to real data, we present an alternative method for determining the OPE coefficients that might help estimating, and possibly even reducing, this systematic error.

2008-03-03

412

Total hemispherical emittance measured at high temperatures by the calorimetric method  

Energy Technology Data Exchange (ETDEWEB)

A calorimetric vacuum emissometer (CVE) capable of measuring total hemispherical emittance of surfaces at elevated temperatures was designed, built, and tested. Several materials with a wide range of emittances were measured in the CVE between 773 to 923 K. These results were compared to values calculated from spectral emittance curves measured in a room temperature Hohlraum reflectometer and in an open-air elevated temperature emissometer. The results differed by as much as 0.2 for some materials but were in closer agreement for the more highly-emitting, diffuse-reflecting samples. The differences were attributed to temperature, atmospheric, and directional effects, and errors in the Hohlraum and emissometer measurements ({+-} 5 percent). The probable error of the CVE measurements was typically less than 1 percent.

1994-09-01

413

Total and spontaneous fission half-lives for americium and curium nuclides  

Science.gov (United States)

The long-lived nuclides of the americium curium elements are of interest for their use in certain safeguard applications and for nuclear reactor burnup studies in waste management. Recommended values are presented for /sup 241,242m,243/Am, and for /sup 242,243,244,245,246,247,248,250/Cm. These values result from a consistent evaluation of all these half-lives. These preliminary estimates were presented earlier. The uncertainties are provided at the 95% confidence limit for each of the recommended values. It will be noted that many of the recommended errors considerably exceed errors quoted by individual authors in their publication, by up to an order of magnitude, e.g., the total half-life of /sup 242,246,248/Cm and the spontaneous fission half-life of /sup 244/Cm. 65 refs., 18 tabs.

1985-01-01

414

Standing-Wave Free-Electron Laser Two-Beam Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A free-electron laser (FEL) two-beam accelerator (TBA) is proposed, in which the FEL interaction takes place in a series of drive cavities, rather than in a waveguide. Each drive cavity is 'beat-coupled' to a section of the accelerating structure. This standing-wave TBA is investigated theoretically and numerically, with analyses included of microwave extraction, growth of the FEL signal through saturation, equilibrium longitudinal beam dynamics following saturation, and sensitivity of the microwave amplitude and phase to errors in current and energy. It is found that phase errors due to current jitter are substantially reduced from previous versions of the TBA. Analytic scalings and numerical simulations are used to obtain an illustrative TBA parameter set.

1991-02-01

415

Optimized short term power plant operation scheduling under consideration of load forecast errors; Kurzfristige Kraftwerkseinsatzoptimierung unter Beruecksichtigung von Lastprognosefehlern  

Energy Technology Data Exchange (ETDEWEB)

A programme to optimize the short-term operation planning of hydrothermal system scheduling is presented. Based on heuristics, an operational planning of pumped storage plants and a method for fast evaluations of spot market deals under consideration of load forecast errors was developed. (orig.) [German] Vorgestellt wird ein Programm, das - basierend auf Heuristiken - den kurzfristigen Einsatz eines hydrothermischen Kraftwerksparks optimiert. Im Programm wurde dazu ein Verfahren zur Pumpseichereinsatzplanung und zur sekundenschnellen Bewertung von Spot-Markt-Geschaeften unter Beruecksichtigung von Lastprognosefehlern entwickelt. (orig.)

2001-07-01

416

Optimization techniques for parameter estimations: case studies in CO{sub 2} separation processes  

Energy Technology Data Exchange (ETDEWEB)

Application of an optimization technique to extract the non-ideal parameters of gas absorption with chemical reactions process was described. The gas absorption was modeled using mass transfer theory to represent the realistic behaviors of an absorber. The model was a highly non-linear iterative model which correlated the overall rate of absorption as the function of unknown non-ideal parameters, including the physical liquid mass transfer coefficient and the wetted interfacial area of of packings. The optimization program was developed to minimize the sum of squares of relative errors between the model predictions and the experimental data. Four sets of experimental data (case studies) with different operating conditions were used for extracting parameters. Comparisons between predicted and experimental measured overall absorption rate were in good agreement, average absolute value of relative errors not exceeding 5.4 %. 18 refs., 3 tabs., 4 ...

1995-12-31

417

Numerical and experimental investigation of shellside characteristics for RODbaffle heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

RODbaffle heat exchanger is a kind of shell-and-tube heat exchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat transfer on shellside of the RODbaffle heat exchanger were analyzed using the simulation ...

2008-05-15

418

Kolmogoroff constants at the 1976 ITCE  

Energy Technology Data Exchange (ETDEWEB)

The high-frequency data from 12 sensors at the ITCE 1976 are analyzed to determine the Kolmogoroff constants for velocity, temperature and humidity fluctuations, ..cap alpha../sub u/, ..cap alpha../sub T/, and ..cap alpha../sub q/. The occurrence of aliasing in the spectral analysis in some cases together with the limited response of some sensors at the higher frequencies introduces some uncertainties into the analysis. The Soviet sonic anemometer, fine-wire thermometer and infrared hygrometer and the Australian infrared hygrometer provide the best information, namely that: ..cap alpha../sub u/ = 0.59 +/- 0.01, ..cap alpha../sub T/ = 0.68 +/- 0.02, ..cap alpha../sub q/ = 0.76 +/- 0.03, where the errors quoted refer solely to statistical errors. The other instruments provide general support to these values. The technique of using spectral density measurements to determine eddy fluxes is illustrated.

1982-01-01

419

Improvement of tracking performance using prediction-based algorithms for a maneuvering target  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a study involving prediction of a complicated maneuvering target, with the aim of improving the tracking performance of a fire control system (FCS). In this study, we predict the position of a complicated maneuvering target 5 s in advance using the information up to the current time. Because of the large error caused by the complicated maneuvers and the long prediction time interval, the mechanical system of the fire control system will take a heavy load. In order to cope with this problem, several approaches to decreasing the prediction error have been proposed including the prediction algorithms based on the multiple model(MM) filter, interacting multiple model (IMM) filter, and variable dimension with input estimation (VDIE) filter. Finally, comparative simulation re...

2011-01-01

420

From Whitney Forms to Metamaterials: a Rigorous Homogenization Theory  

CERN Document Server

A rigorous homogenization theory of metamaterials -- artificial periodic structures judiciously designed to control the propagation of electromagnetic waves -- is developed. All coarse-grained fields are unambiguously defined and effective parameters are then derived without any heuristic assumptions. The theory is an amalgamation of two concepts: Smith & Pendry's physical insight into field averaging and the mathematical framework of Whitney-Nedelec-Bossavit-Kotiuga interpolation. All coarse-grained fields are defined via Whitney forms and satisfy Maxwell's equations exactly. The new approach is illustrated with several analytical and numerical examples and agrees well with the established results (e.g. the Maxwell-Garnett formula and the zero cell-size limit) within the range of applicability of the latter. The sources of approximation error and the respective suitable error indicators are clearly identified, along with systematic routes ...

2010-01-01

421

Establishment of a method for RIA of transferrin  

International Nuclear Information System (INIS)

Objective: To develop a method for RIA of transferrin without dilution of the serum sample. Methods: The measurable range was broadened through: Lowering of the specific radioactivity of the labelled antigen, increasing the concentration of the anti-serum and improve the curve fitting method. Results: The antiserum affinity was 3.82 x 10"-"1"0 mol/L, the specific radioactivity of the labelled antigen was 15.3 mg/mic, inter-assay error CV 5.38%, intra-assay error CV = 3.5% and the shape of the curve was good. For 30 normal control specimens, the mean TF content was 2.81 +- 0.972 mg/ml. Conclusion: Development of a method for RIA of TF without previous dilution of the test serum was of clinical value

2002-04-01

422

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

423

Design concept for radiation hardening of low power and low voltage dynamic memories  

International Nuclear Information System (INIS)

A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.

424

Covariances for neutron cross sections calculated using a regional model based on local-model fits to experimental data  

Energy Technology Data Exchange (ETDEWEB)

We suggest a procedure for estimating uncertainties in neutron cross sections calculated with a nuclear model descriptive of a specific mass region. It applies standard error propagation techniques, using a model-parameter covariance matrix. Generally, available codes do not generate covariance information in conjunction with their fitting algorithms. Therefore, we resort to estimating a relative covariance matrix a posteriori from a statistical examination of the scatter of elemental parameter values about the regional representation. We numerically demonstrate our method by considering an optical-statistical model analysis of a body of total and elastic scattering data for the light fission-fragment mass region. In this example, strong uncertainty correlations emerge and they conspire to reduce estimated errors to some 50% of those obtained from a naive uncorrelated summation in quadrature. 37 references.

1983-11-01

425

Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results from the model ...

1986-09-01

426

Authentication of byte sequences  

Energy Technology Data Exchange (ETDEWEB)

Algorithms for the authentication of byte sequences are described. The algorithms are designed to authenticate data in the Storage, Retrieval, Analysis, and Display (SRAD) Test Data Archive of the Radiation Effects and Testing Directorate (9100) at Sandia National Laboratories, and may be used in similar situations where authentication of stored data is required. The algorithms use a well-known error detection method called the Cyclic Redundancy Check (CRC). When a byte sequence is authenticated and stored, CRC bytes are generated and attached to the end of the sequence. When the authenticated data is retrieved, the authentication check consists of processing the entire sequence, including the CRC bytes, and checking for a remainder of zero. The error detection properties of the CRC are extensive and result in a reliable authentication of SRAD data.

1991-06-01

427

Approximate MIMO Iterative Processing with Adjustable Complexity Requirements  

CERN Document Server

Targeting always the best achievable bit error rate (BER) performance in iterative receivers operating over multiple-input multiple-output (MIMO) channels may result in significant waste of resources, especially when the achievable BER is orders of magnitude better than the target performance (e.g., under good channel conditions and at high signal-to-noise ratio (SNR)). In contrast to the typical iterative schemes, a practical iterative decoding framework that approximates the soft-information exchange is proposed which allows reduced complexity sphere and channel decoding, adjustable to the transmission conditions and the required bit error rate. With the proposed approximate soft information exchange the performance of the exact soft information can still be reached with significant complexity gains.

2011-01-01

428

A Preliminary Investigation of the Reinforcement Function of Signal Detections in Simulated Baggage Screening: Further Support for the Vigilance Reinforcement Hypothesis  

Science.gov (United States)

The vigilance reinforcement hypothesis (VRH) asserts that errors in signal detection tasks are partially explained by operant reinforcement and extinction processes. VRH predictions were tested with a computerized baggage screening task. Our experiment evaluated the effects of signal schedule (extinction vs. variable interval 6 min) and visual field complexity (dial vs. baggage x-ray) on search behavior rates. There was a main effect for signal schedule [F (1, 20) = 14.0, p = 0.001, p[subscript rep] = 0.99], but no effects for field complexity or interaction. The VRH suggests that performance errors in visual screening work may be reduced through operant conditioning of search behaviors by intensive management of artificially planted signals. (Contains 1 table and 3 figures.)

2008-12-01

429

Yucca Mountain Task 4, Final report FY 1993  

Energy Technology Data Exchange (ETDEWEB)

Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.

1993-09-30

430

VDMA contribution to functional safety of turbo-machines - A necessary risk reduction by means of safety function for steam turbines; VDMA-Beitrag zur Funktionalen Sicherheit von Turbomaschinen. Notwendige Risikoreduktion durch Schutzfunktionen fuer Dampfturbinen  

Energy Technology Data Exchange (ETDEWEB)

In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.

2010-07-01

431

Review of electron beam therapy physics  

Energy Technology Data Exchange (ETDEWEB)

For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)

2006-07-07

432

Response of track-etch dosemeters to environmental radon  

Energy Technology Data Exchange (ETDEWEB)

The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).

1988-01-01

433

Reliable dates for the last 50.000 years; Des dates fiables pour les 50 000 dernieres annees  

Energy Technology Data Exchange (ETDEWEB)

The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)

2004-03-01

434

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

435

Proceedings of the fourth international airborne remote sensing conference and exhibition/ 21st Canadian symposium on remote sensing  

Energy Technology Data Exchange (ETDEWEB)

The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.

1999-07-01

436

Primary standardization of {sup 242} Am radioactive sources  

Energy Technology Data Exchange (ETDEWEB)

The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)

2001-07-01

437

Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region  

Science.gov (United States)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

438

Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.

2009-05-15

439

Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions  

Energy Technology Data Exchange (ETDEWEB)

It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

2000-07-01

440

Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.

1988-09-18

441

Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials  

International Nuclear Information System (INIS)

The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)

2000-10-05

442

In situ observation of axial irradiation growth in liquid-metal reactor metal fuel  

International Nuclear Information System (INIS)

Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.

1989-11-26

443

High Exposure Facility Technical Description  

Energy Technology Data Exchange (ETDEWEB)

The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."

2008-02-12

444

FADC signal reconstruction for the MAGIC telescope  

Energy Technology Data Exchange (ETDEWEB)

Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.

2008-09-11

445

Experimental Uncertainty for the Thermal Expansion of a Simulated Fuel  

Energy Technology Data Exchange (ETDEWEB)

Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.

2006-07-01

446

Electron capture decay of sup 203 Pb  

Energy Technology Data Exchange (ETDEWEB)

Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).

1989-01-01

447

ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD  

Energy Technology Data Exchange (ETDEWEB)

A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.

1983-01-01

448

Determining nuclear morphology using an improved angle-resolved low coherence interferometry system  

Science.gov (United States)

We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.

2003-12-01

449

Dependence of thermal plasma jet temperature on discharge power and gas flow rate  

International Nuclear Information System (INIS)

With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)

2008-03-01

450

Beam position monitor readout and control in the SLC linac  

Energy Technology Data Exchange (ETDEWEB)

A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.

1985-04-01

451

A theoretical study of radon measurement with activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.

1998-04-11

452

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex configurations such ...

2007-08-01

453

A study of neutron room scattering at RPCF  

International Nuclear Information System (INIS)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1997-01-05

454

A study of neutron room scattering at RPCF  

Energy Technology Data Exchange (ETDEWEB)

High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...

1996-09-01

455

The safety concept of public gas supply in Germany  

Energy Technology Data Exchange (ETDEWEB)

The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)

1997-09-01

456

The nucleon axial charge in full lattice QCD  

Energy Technology Data Exchange (ETDEWEB)

The nucleon axial charge is calculated as a function of the pion mass in full QCD. Using domain wall valence quarks and improved staggered sea quarks, we present the first calculation with pion masses as light as 354 MeV and volumes as large as (3.5 fm)3. We show that finite volume effects are small for our volumes and that a constrained fit based on finite volume chiral perturbation theory agrees with experiment within 5% statistical errors.

2005-10-13

457

Swift Observations of GRB 070318 - GCN - NASA  

Science.gov (United States)

Apr 16, 2007 ... with a 1-sigma error radius of about 0.5 arc sec. ... It was consistent with a single point source at: RA (J2000) = 03h 13m 57.6s ... At 13000 sec. after the trigger, the magnitude in the UVOT B filter was ~19.9 with a ...

458

Self-correcting Multigrid Solver  

Energy Technology Data Exchange (ETDEWEB)

A new multigrid algorithm based on the method of self-correction for the solution of elliptic problems is described. The method exploits information contained in the residual to dynamically modify the source term (right-hand side) of the elliptic problem. It is shown that the self-correcting solver is more efficient at damping the short wavelength modes of the algebraic error than its standard equivalent. When used in conjunction with a multigrid method, the resulting solver displays an improved convergence rate with no additional computational work.

2004-06-29

459

Risk analysis for the SNR-300 project. Pt. 1. Risikoorientierte Analyse zum SNR 300. T. 1  

Energy Technology Data Exchange (ETDEWEB)

The volume contains reports on plant technology, on systems organisation with the aim to minimize the risk (human error), on the problem of seismic risk, on core-disruptive accidents and on accident consequence models with different release categories and a comparison of the potential damage incurred. Mr. Webb; one of the authors, attempts to disprove the objections to his two earliest SNR statements by experts of Karlsruhe Nuclear Research Centre.

1982-01-01

460

Risk analysis for the SNR-300 project. Pt. 1  

International Nuclear Information System (INIS)

The volume contains reports on plant technology, on systems organisation with the aim to minimize the risk (human error), on the problem of seismic risk, on core-disruptive accidents and on accident consequence models with different release categories and a comparison of the potential damage incurred. Mr. Webb; one of the authors, attempts to disprove the objections to his two earliest SNR statements by experts of Karlsruhe Nuclear Research Centre. (AK).

461

Quantum computing with trapped ions  

Energy Technology Data Exchange (ETDEWEB)

Quantum computers hold the promise of solving certain computational tasks much more efficiently than classical computers. We review recent experimental advances towards a quantum computer with trapped ions. In particular, various implementations of qubits, quantum gates and some key experiments are discussed. Furthermore, we review some implementations of quantum algorithms such as a deterministic teleportation of quantum information and an error correction scheme.

2008-12-15

462

Quantum computing and probability  

Energy Technology Data Exchange (ETDEWEB)

Over the past two decades, quantum computing has become a popular and promising approach to trying to solve computationally difficult problems. Missing in many descriptions of quantum computing is just how probability enters into the process. Here, we discuss some simple examples of how uncertainty and probability enter, and how this and the ideas of quantum computing challenge our interpretations of quantum mechanics. It is found that this uncertainty can lead to intrinsic decoherence, and this raises challenges for error correction. (viewpoint)

2009-11-25

463

Presentation of twentieth century atmospheric carbon dioxide record in Smithsonian spectrographic plates  

Energy Technology Data Exchange (ETDEWEB)

The observed strength of the carbon dioxide absorption bands recorded on spectrobolograms of the transparency of the earth's atmosphere between wavelengths 300 and 2500 nanometers as part of the Smithsonian Solar Constant Program were used to extract the abundance of carbon dioxide in the atmosphere. The details of the analysis and the sources of error are discussed. 11 references, 5 figures, 1 table. (ACR)

1983-11-01

464

Predictive wavefront control for Adaptive Optics with arbitrary control loop delays  

Energy Technology Data Exchange (ETDEWEB)

We present a modification of the closed-loop state space model for AO control which allows delays that are a non-integer multiple of the system frame rate. We derive the new forms of the Predictive Fourier Control Kalman filters for arbitrary delays and show that they are linear combinations of the whole-frame delay terms. This structure of the controller is independent of the delay. System stability margins and residual error variance both transition gracefully between integer-frame delays.

2007-10-30

465

Precision Measurements of the Cluster Red Sequence using an Error Corrected Gaussian Mixture Model  

Energy Technology Data Exchange (ETDEWEB)

The red sequence is an important feature of galaxy clusters and plays a crucial role in optical cluster detection. Measurement of the slope and scatter of the red sequence are affected both by selection of red sequence galaxies and measurement errors. In this paper, we describe a new error corrected Gaussian Mixture Model for red sequence galaxy identification. Using this technique, we can remove the effects of measurement error and extract unbiased information about the intrinsic properties of the red sequence. We use this method to select red sequence galaxies in each of the 13,823 clusters in the maxBCG catalog, and measure the red sequence ridgeline location and scatter of each. These measurements provide precise constraints on the variation of the average red galaxy populations in the observed frame with redshift. We find that the scatter of the red sequence ridgeline increases mildly with redshift, and that the slope ...

2009-07-01

466

Practical Aspects of Kalman Filtering Implementation  

Science.gov (United States)

... L z xyx 0 0 0 0 0 0 0 0 0 0 0 0 -V 0 0 0 0 oj A ~ 0 0 1 0 v 0 I - z Fiue2. Inertial Navigation Error Lquation-i in the Platform Frame t 'I A Page 35. ...

1976-03-01

467

P-odd asymmetries in deep inelastic scatterings of polarized leptons on nuclei  

International Nuclear Information System (INIS)

The P-odd asymmetries in deep inelastic scattering (DIS) of polarized leptons on nuclei are considered in the framework of the standard model and the parton-flucton model. The model predictions, within the experimental errors,agree well with the present data. 13 refs., 2 figs., 2 tabs. (author).

468

On stochastic approximation algorithms for classes of PAC learning problems  

Energy Technology Data Exchange (ETDEWEB)

The classical stochastic approximation methods are shown to yield algorithms to solve several formulations of the PAC learning problem defined on the domain [o,1]{sup d}. Under some assumptions on different ability of the probability measure functions, simple algorithms to solve some PAC learning problems are proposed based on networks of non-polynomial units (e.g. artificial neural networks). Conditions on the sizes of these samples required to ensure the error bounds are derived using martingale inequalities.

1994-03-01

469

Measurement of the oil consumption of compressors  

International Nuclear Information System (INIS)

This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).

470

Magnetic diagnostic of beta poloidal and internal inductance of plasma in the TCA/BR tokamak  

Energy Technology Data Exchange (ETDEWEB)

This report continues the studies of simplified methods, of magnetic diagnostics in application to TCA/BR tokamak. Here we study the accuracy of known formula for {beta}{sub 1} + l{sub 1}/2 determination from the poloidal magnetic field asymmetry. Errors of the diamagnetic measurements due to vibrations of the vacuum vessel are also considered. (author). 3 refs., 1 fig., 1 tab.

1996-12-31

471

In Pursuit of Spreadsheet Excellence  

CERN Document Server

The first fully-documented study into the quantitative impact of errors in operational spreadsheets identified an interesting anomaly. One of the five participating organisations involved in the study contributed a set of five spreadsheets of such quality that they set the organisation apart in a statistical sense. This virtuoso performance gave rise to a simple sampling test - The Clean Sheet Test - which can be used to objectively evaluate if an organisation is in control of the spreadsheets it is using in important processes such as financial reporting.

2008-01-01

472

Improved measurement of $\\psi (2S)$ decays into $\\tau ^{+}\\tau ^{-}$  

CERN Document Server

Using 14M $\\psi (2S)$ events collected at BESII, the branching fraction of $\\psi (2S)\\to \\tau ^{+}\\tau ^{-}$ is measured to be $Br_{\\tau \\tau}=(3.10\\pm 0.21\\pm 0.38)\\times 10^{-3}$, where the first error is statistical and the second is systematic.

2006-01-01

473

Grid-Search Location Methods for Ground-Truth Collection from Local and Regional Seismic Networks  

Energy Technology Data Exchange (ETDEWEB)

The objective of this project is to develop improved seismic event location techniques that can be used to generate more and better quality reference events using data from local and regional seismic networks. Their approach is to extend existing methods of multiple-event location with more general models of the errors affecting seismic arrival time data, including picking errors and errors in model-based travel-times (path corrections). Toward this end, they are integrating a grid-search based algorithm for multiple-event location (GMEL) with a new parameterization of travel-time corrections and new kriging method for estimating the correction parameters from observed travel-time residuals. Like several other multiple-event location algorithms, GMEL currently assumes event-independent path corrections and is thus restricted to small event clusters. The new parameterization assumes that travel-time corrections are a ...

2003-07-24

474

Genome Sequence of a Lancefield Group C Streptococcus zooepidemicus Strain Causing Epidemic Nephritis: New Information about an Old Disease  

UK PubMed Central (United Kingdom)

Outbreaks of disease attributable to human error or natural causes can provide unique opportunities to gain new information about host-pathogen interactions and new leads for pathogenesis research....Full Text Available

475

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

476

Fundamentals of polymeric materials  

Energy Technology Data Exchange (ETDEWEB)

The polymer industry is a young industry that has undergone tremendous growth and change over the last sixty years. Many important discoveries in polymer science have been accidental. Most of the learning has been by trial and error and most of the understanding is still basically empirical--make a polymer material or compound and then put it to the test to study what it is and how it performs. This article provides an overview of what polymers and polymer compounds are, why they behave as they do, and it discusses several examples of failures of rubber and plastic components.

1998-12-31

477

Finding the best quadratic approximation of a function  

British Library Electronic Table of Contents (United Kingdom)

This article examines the question of finding the best quadratic function to approximate a given function on an interval. The prototypical function considered is f(x) = ex. Two approaches are considered, one based on Taylor polynomial approximations at various points in the interval under consideration, the other based on the fact that three non-collinear points determine a unique quadratic function. Three different techniques for measuring the error in the approximations are considered.

2011-01-01

478

Evaluating the metrology of the standard method of determining blast furnace coke strength  

Science.gov (United States)

Coke strength increases in significance as blast furnace and metallurgical plant gain in size and output requirement. The article underlines the need to apply error computation standards to strength testing routines. The mean square deviation was found for cokes from different plants, related to a single strength determination for M25 and M10, and amounted to 0.61 and 0.35% respectively. The future standards should include a correlation factor for permitted tolerance as between parallel determinations.

1981-03-01

479

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

480

Errors arising through using the Harvard tables and percentage levels of median weight-for-age in assessing nutritional status.  

UK PubMed Central (United Kingdom)

A self-selected sample of 417 urban and 379 rural preschool children attending the under-5s clinics was weighed in Sierra Leone. The individual weights were related to the weight-for-age Harvard 3rd...Full Text Available

1977-05-01

481

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

482

Detection of aortoarterial graft infections by leukocyte scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.

1983-09-01

483

Construction of a data analyzer computer program for neutron activation analysis  

International Nuclear Information System (INIS)

A new software for neutron activation analysis was designed, built and implemented on a desktop computer using Visual Basic 6.0 program. The construction of this data analyzer computer program is described. The new software deals with peak reports resulting from Gammaplus software with minimum interference from the user in order to save time, manpower and minimize human errors. Its ability to find the concentrations of chemical elements within samples is proven to be fast, reliable and user friendly. (author)

484

Clinical translation of ultraviolet autofluorescence microscopy towards endomicroscopy for early detection of cancer  

Science.gov (United States)

The non-invasiveness of autofluorescence technology may reduce sampling error and time delay for histopathology diagnosis. We establish biophotonic methods and guidelines to visualize and interpret early epithelial tissue changes that signify disease. Flexible and rigid fiber endomicroscopy instrumentation design parameters feasible for translation towards clinical use are in development.

2010-12-01

485

Cause trending analysis for licensing operational events in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The human causal factors for all human error licensing operational events on Daya Bay nuclear power station since 1993 to 2003 are categorized, the trend of these causal factors is analyzed. The emphasis is placed on analyzing the deficiencies on complying with and executing regulations and procedures. The results provide directional reference for nuclear power station to improve human performance. (author)

2005-09-01

486

An Hp-Adaptive Hierarchical Formulation for the Boundary Element Method Applied to Elasticity in Two Dimensions  

Scientific Electronic Library Online (English)

Abstract in english This paper presents an HP-Adaptive Procedure with Hierarchical formulation for the Boundary Element Method in 2-D Elasticity problems. Firstly, H, P and HP formulations are defined. Then, the hierarchical concept, which allows a substantial reduction in the dimension of equation system, is introduced. The error estimator used is based on the residual computation over each node inside an element. Finally, the HP strategy is defined and applied to two examples.

2002-03-01

487

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

488

A simple system of instruments for radionuclide X-ray fluorescence analysis in nonferrous metallurgy  

International Nuclear Information System (INIS)

Proceeding from commercially available instruments, a simple measuring system has been established, which renders possible fast and simple discontinuous analysis of individual elements. This measuring system is described, giving some examples of utilization in nonferrous metallurgy (mining, ore dressing, metallurgical treatment), and specific details, such as error of measurement, ranges of measurement and limits of utilization. (author).

1979-01-01

489

A note on asymptotic stability of an interval neutral delay-differential system  

British Library Electronic Table of Contents (United Kingdom)

This paper mainly considers the asymptotic stability of interval neutral delay-differential systems, which corrects a technical error in the proof given in [Applied Math. Letters, 16(2003) 1063-1068] by a linear fractional transformation of an interconnection matrix with structured real parametric uncertainties. In addition, a new condition, in terms of the structured singular value, is provided to ensure the stability of the interval system. Finally, an example is given to demonstrate the validity of our criteria.

2012-01-01

490

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

491

Use of Teflon-embedded calcium sulphate: dysprosium thermoluminescent dosimeters for chest radiography  

Energy Technology Data Exchange (ETDEWEB)

As part of a U.S. multi-regional pilot study conducted by the six Centers for Radiological Physics, 12-mm-diameter by 0.4-mm-thick CaSO/sub 4/:Dy Teflon-embedded discs were evaluated and used to measure patient entrance exposure on 60 average patients at 12 clinical centers. The discs were found to have adequate sensitivity, reproducibility and linearity up to 69.7 microC kg-1 (270 mR). The minimum measurable exposure was estimated as 0.4 microC kg-1 (1.5 mR). All responses were corrected for energy dependence, which varied +/- 20% from 1.7 to 6.5 mm Al half-value layer. Patient entrance exposure values ranged from 1.3 to 28 microC kg-1 (5 to 110 mR), with a median value of 5.2 microC kg-1 (20 mR). This value agreed with exposure measurements made on the chest radiography equipment using an ionization chamber and a phantom which simulated an average patient, and with published Nationwide Evaluation of X-Ray Trends (NEXT) data for the same period.

1987-12-01

492

Scatter measurements for optical cone-beam computed tomography  

Energy Technology Data Exchange (ETDEWEB)

Both x-ray and optical cone-beam CT (CBCT) scanners are limited by scattered photons that contaminate the primary images. Transparent radiochromic gels and plastics are anticipated to produce less scattering than polymerization gels and hence result in reconstructed dose distributions with greater contrast and dynamic range. Four methods of scatter measurement were investigated to quantify scatter fractions using an in-house optical CBCT scanner. The methods consisted of generating either 'coin' shadows or primary beamlets in transmission images. The four methods generated similar results of 10% scatter fractions in gel transmission images for this particular scanner configuration with both leuco crystal violet and carbon black micelle gels. The scatter contributions were distributed as 5% from micelle gel, 2% from Teflon wall, 2% from refractive index matching liquid and 1% other sources. Applying a uniform background subtraction of 2% of open field intensity ...

2009-05-01

493

Pharmacokinetic and dosimetric characteristics of some thallium isotopes  

International Nuclear Information System (INIS)

Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the dose from lead-201 and lead-203 may be ignored. Doses from thallium-199 preparation per activity unit ...

494

Measurement of spatial dose distribution with thermoluminescence sheet around high dose-rate intracavitary sup 60 Co sources  

Energy Technology Data Exchange (ETDEWEB)

A thermoluminescence (TL) sheet and its spatial readout system for in vivo measurement of spatial dose distribution around sources has been newly developed for intracavitary high dose-rate radiation therapy. The TL sheet (40 cm x 50 cm x 200 {mu}m), which is composed of teflon mixed with BaSO{sub 4} (Eu doped) powder, has a linear response with a very wide dynamic range from at least 0.002 cGy to 5000 cGy for {sup 60}Co sources. Phantom test of the TL sheet readout system demonstrated that absorbed dose with TL sheet and that with ionization chamber as standard dosimeter agreed well. For clinical application, TL sheet was attached on an applicator of intracavitary radiation therapy for rectal cancer. After irradiation with high dose-rate {sup 60}Co sources, the in vivo dose distribution on the surface of the rectum was determined. The TL sheet was suggested to provide a convenient means of measuring the dose distribution around {sup 60}Co sources in intracavitary ...

1991-06-01

495

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the risk per unit energy imparted can significantly underestimate the ...

496

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two detectors, respectively and the imaging quality of phantoms. Preliminary results showed that the system is ...

2007-01-01

497

Determinations of organ or tissue doses to survivors in Hiroshima and Nagasaki  

International Nuclear Information System (INIS)

For the purpose of risk estimates from radiation carcinogenesis including leukemogenesis and radiation genetic effects, the biological significant dose is not the tissue kerma in air but the absorbed dose in organ or tissue with respect to carcinogenic and leukemogenic effects or genetic effects. In order to estimate organ or tissue dose from the tissue kerma in air, a ratio of the organ or tissue dose to the tissue kerma in air for survivors in Hiroshima and Nagasaki was calculated with the aid of the Snyder's mathematical phantoms constructed so as to simulate the body shape of survivors aged 5, 10 years old and adult at the time of atomic bomb detonations. The ratios were corrected for the angular distribution of atomic bomb radiations, assuming an anisotropic angular distribution for the survivors exposed to the atomic bombs in open air and the isotropic distribution for the survivors incide a Japanese house or other structures. The resultant ratios are ...

1980-01-01

498

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can ...

2004-03-21

499

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes in image quality ...

2004-03-21