Energy Technology Data Exchange (ETDEWEB)
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
2009-10-15
International Nuclear Information System (INIS)
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
2009-10-01
International Nuclear Information System (INIS)
An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)
International Nuclear Information System (INIS)
A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium content in process residues and wastes is 5% ...
1998-09-01
Development of a radon standard source
Energy Technology Data Exchange (ETDEWEB)
The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].
2005-06-11
Energy Technology Data Exchange (ETDEWEB)
This thesis presents the work achieved to instrument the ATLAS software framework, ATHENA, with a library of tools and utensils for the physics analysis as well as the extraction of the jet energy scale using physics events (in-situ calibration). The software part presents the various components of the ATHENA framework which handles the simulated and reconstructed data flow as well as the different stages of this process, before and during the data taking. The building of a library of tools easing the reconstruction of physics objects, their association with Monte-Carlo particles and their API is then explained. The need for common language and collaboration-wide utensils is emphasised as it allows to share the workload of validating these tools and to get reproducible physics results. The analysis part deals with the implementation of a light jet energy scale calibration algorithm within the C++ framework. This ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
The theme of the conference was recent developments in airborne remote sensing and their applications. The proceedings contain the papers presented at 14 general sessions and 13 interactive sessions covering airborne platforms, sensor systems, airborne/spaceborne synergy, atmospheric and oceanic measurements, land cover/land use, emergency response and reconnaissance, data handling, forestry, agriculture, water resources, geospatial reference, system calibration, environmental monitoring and planning, and information product advancements. Two papers are abstracted separately.
1999-07-01
Energy Technology Data Exchange (ETDEWEB)
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.
1985-03-01
DOE assay methods used for characterization of contact-handled transuranic waste
International Nuclear Information System (INIS)
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for ...
DOE assay methods used for characterization of contact-handled transuranic waste
Energy Technology Data Exchange (ETDEWEB)
US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not yet have established American Society for ...
1991-08-01
International Nuclear Information System (INIS)
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...
2007-08-01
International Nuclear Information System (INIS)
... interval analyzers counting techniques discriminators electronic circuits
Development of calibration facility for radiation protection monitoring instruments
International Nuclear Information System (INIS)
Exposure control at the operating Nuclear Power Station is a major concern. The challenging task of meeting the International standards in the field of radiation protection is the calibration of the radiation monitoring instruments and interpretation of personnel and area monitoring results. Correct interpretation is based on accurate calibration of radiation measuring instruments. The reliability and accuracy of the measurements are also partly based on the procedures applied in calibration. Inadequate calibration can cause large errors in dose estimation in complete dose rate range and energy range. Semiautomatic calibration facility established at TAPS 3 and 4 for radiation monitoring instruments. Objective of calibration facility is (a) Ensure instruments are working properly (b) calibration adjustment and (c) in case without ...
2008-11-19
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...
2007-11-15
Remote handling and robotics in nuclear field
International Nuclear Information System (INIS)
The application of remote handling and robotics, the state of the art and some uses in the man-machine interface are described. (E.G.).
Prospects of robotics research in the field of remote handling systems
International Nuclear Information System (INIS)
The main trends of research carried out in remote handling systems in the fields of ergonomy, robotics and reliability are presented.
Uncertainty analysis of high altitude aircraft air mass zero solar cell calibration
Energy Technology Data Exchange (ETDEWEB)
Recently the ISO standards organization has requested the PV community to establish AMO calibration methodologies for space solar cells. The PV community responded by organizing a series of workshops to review and recommend AMO calibration techniques. One of the activities of the workshop is to review the various calibration methodologies and conduct a comprehensive uncertainty analysis of each method. This paper outlines NASA`s methodology of AMO calibration using the high altitude aircraft method.
1997-12-31
Range accuracy in carbon ion treatment planning based on CT-calibration with real tissue samples
UK PubMed Central (United Kingdom)
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Calibration of the solar UV radiometers in Finland
Energy Technology Data Exchange (ETDEWEB)
In this report, the main emphasis is given to (1) the problems associated with the basic calibration of the spectroradiometer and (2) the year-to-year variability of the calibrations of the solar UV network radiometers. Also, the results from intercomparisons of the Brewer and OL 742 spectroradiometers are included
1996-12-31
Estimation of half-life values of actinide radionuclides
International Nuclear Information System (INIS)
... actinides americium 241 americium 242 americium 243 calibration standards
1986-04-15
The activity assay of a radiopharmaceutical administration to a patient is normally achieved via the use of a radionuclide calibrator. Because of the different geometries and elemental compositions between plastic syringes and glass vials, the calibration factors for syringes may well be significantly different from those for the glass containers. The magnitude of these differences depends on the energies of the emitted photons. For some radionuclides variations have been observed of 70 %, it is therefore important to recalibrate for syringes or use syringe calibration factors. Calibration factors and volume correction factors have been derived for the NPL secondary standard radionuclide calibrator, for a variety of commonly used syringes and needles, for the most commonly used medical radionuclide.
2002-01-01
Vibration suppressor for a manual perforator
Energy Technology Data Exchange (ETDEWEB)
A device is presented with handle containing hinges and work support arm, a flexible pin with supports and extra weights. The flexible pin is equipped with cantilevered sergments and weights. The bracket hinges on the handle are perpendicular to the axis of the flexible pin. To reduce handle vibration during drilling hard rock, the handle and brackets are joined to allow relative movement on the surface perpendicular to the hinges of the work support arm. The handle is joined to the work support arm parallel to the sides and the work support arm has holes to accomodate this. Elastic bushings are located between the lateral sides of the work support arm where it is joined to the handle.
1983-01-01
Highly enriched isotope samples of uranium and transuranium elements for scientific investigation
International Nuclear Information System (INIS)
The paper describes the production of highly enriched isotopes of uranium, plutonium, americium and curium by electromagnetic separation for scientific and applied researches in physics, chemistry, geology, medicine, biology and other fields. Using the equipment described, the isotopes are produced in quantities sufficient to set up nuclear physical experiments, to produce nuclear reference materials and standard sources for calibration of radiometrical and mass spectrometrical equipment, in radionuclide metrology, etc. For the following isotopes the indicated degrees of isotopic enrichment were achieved: "2"3"3U-99.97%; "2"3"5U-99.97%; "2"3"6U-98.0%; "2"3"8U-99.997%; "2"3"8Pu-99.6%; "2"3"9Pu-99.9977%; "2"4"0Pu-99.9-100%; "2"4"1Pu-96.998%; "2"4"2Pu-97.8-99.96%; "2"4"4Pu-96.7%; "2"4"1Am-99.6%; "2"4"2"mAm-73.6%; "2"4"3Am-99.2-99.94%; "2"4"3Cm-99.99%; "2"4"5Cm-99.998%; "2"4"6Cm-99.8%; "2"4"7Cm-90%, "2"4"8Cm-97%. Methods for preparing layers of highly enriched isotopes ...
K and L x-ray production cross sections excited by 14.00--34.16 MeV #alpha#-particle beams
International Nuclear Information System (INIS)
K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and compared to various theoretical models. The data suggest the ...
The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner ...
2009-01-01
"Advanced" data reduction for the AMBER instrument
The amdlib AMBER data reduction software is meant to produce AMBER data products from the raw data files that are sent to the PIs of different proposals or that can be found in the ESO data archive. The way defined by ESO to calibrate the data is to calibrate one science data file with a calibration one, observed as close in time as possible. Therefore, this scheme does not take into account instrumental drifts, atmospheric variations or visibility-loss corrections, in the current AMBER data processing software, amdlib. In this article, we present our approach to complement this default calibration scheme, to perform the final steps of data reduction, and to produce fully calibrated AMBER data products. These additional steps include: an overnight view of the data structure and data quality, the production of night transfer functions from the calibration stars ...
2008-01-01
... wood, kitchen wastes, and human faeces with the ash from such burning deposited and retained in an ...
Getting to grips with remote handling and robotics
International Nuclear Information System (INIS)
A report on the Canadian Nuclear Society Conference on robotics and remote handling in the nuclear industry, September 1984. Remote handling in reactor operations, particularly in the Candu reactors is discussed, and the costs and benefits of use of remote handling equipment are considered. Steam generator inspection and repair is an area in which practical application of robotic technology has made a major advance. (U.K.).
Development of a Standard Data Base and Computer ...
... (Author). Descriptors : (*TERMINAL FLIGHT FACILITIES ... PROGRAMMING, HANDLING), QUEUEING THEORY, STOCHASTIC PROCESSES ...
1973-01-01
Actuating mechanism of a mine combine
Energy Technology Data Exchange (ETDEWEB)
An actuating mechanism of a mine combine is proposed. It includes a rotating platform in a vertical plane on which by hinges with the possibility of rotation parallel to the plane of the platform there are handles with cutting drums and a mechanism for extension of the handle which has hydraulic cylinders. With a decrease in load on the hinges of the handles from bending forces, on the platform between the front edge of the platform and the site of attachment of the handle hinges there are openings. Each handle has a support projection which is placed in this opening with the possibility of movement. A clamp plank is installed on it which covers the opening. The distance from the center of the projection support to the axis of the corresponding hinge is greater than the height of embedding of this hinge into the platform.
1982-01-01
HPA - Radon Calibration Facilities
... Radon gas concentrations are measured using instruments with calibrations traceable to the UK National Physical Laboratory and PTB, Germany. The primary facility is a 43 m3 walk-in chamber accessed by an airlock. Radon gas is maintained at a level in this chamber that is ...
Design Calibration and Field Use of a Stomatal Diffusion Porometer
UK PubMed Central (United Kingdom)
Modifications of the design and calibration procedure of a diffusion porometer permit determinations of stomatal resistance which agree well with results obtained by leaf energy balance. The energy...Full Text Available
1969-06-01
Energy Technology Data Exchange (ETDEWEB)
In the present work, we describe application of binary pseudo-random gratings (BPRG) and arrays (BPRA) as effective 1D and 2D test surfaces suitable for calibration of different surface profilometers, including a number of interferometric microscopes and scatterometers.
2009-06-17
Evaluation of the total oil and oleic acid contents in peanut seeds by low field NMR
International Nuclear Information System (INIS)
... PHYSICAL AND ANALYTICAL CHEMISTRY calibration standards diagrams
2010-08-04
Development and Calibration of Two and Four Wire Water ...
... measurement. Power spectral density measurements are made by the dynamic signal analyzer for each channel. A cross power ...
1992-12-01
CMS Silicon Strip Tracker Performance
In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.
2011-01-01
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization ...
2003-04-08
International Nuclear Information System (INIS)
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
Quality Assurance Program Plan for spent fuel handling and packaging
This plan describes the Quality Assurance Program which will be applied to spent fuel handling and packaging tests conducted at the Area 25 E-MAD facility, Nevada Test Site (NTS).
1979-01-31
UK PubMed Central (United Kingdom)
The purpose of the present study was to determine whether exposure to exogenous physiological concentrations of caffeine influence contractility, Ca2+ handling, and fatigue development...Full Text Available
2009-05-01
NPSNET: Modeling the In-Flight and Terminal Properties of ...
... a way to model a munition's terminal effects in a ... following attributes are handled in a stochastic fashion ... be improved by managing a queue of buffers ...
1992-09-01
Aviation Maintenance Safety Articles, January/February 1990
... These are abnormal and an indication of NAVAIRINST 13340.3 identifies these laboratories a possible breakdown in the fuel-handling equip- ...
1990-02-01
Modification of fuel bundles and associated optimization of fuel handling equipment
Energy Technology Data Exchange (ETDEWEB)
This is a continuation of research that started in July 2007 at the Deep River Science Academy. The research was related to the effects of endplate thickness and misalignment of fuel bundles in the fuel channel on pressure losses of reactor coolant. Based on this research, a new approach to refueling of the CANDU reactor has been developed. It greatly simplifies fuel handling equipment and increases its reliability. It also reduces required staffing, as well as operating and maintenance costs associated with fuel handling. (author)
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are ...
1999-07-01
Use of robotics for radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Radioactive waste shipping and receiving facilities presently planned for commercial and defence high level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in ...
1986-06-16
Use of robotics for radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Radioactive waste shipping and receiving facilities presently planned for commercial and defense high-level nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. If current limits for radiation levels at the cask surface and current handling methods are used, high cumulative personnel exposure to ionizing radiation is projected to occur. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations, suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in ...
1986-06-16
Use of commercial robotics in radioactive waste shipping and receiving
International Nuclear Information System (INIS)
Radioactive waste shipping and receiving facilities presently planned for commercial and defense nuclear waste will handle waste packages at frequencies far in excess of those in common practice today. Unacceptable personnel exposure to ionizing radiation is projected to occur if current limits for radiation levels at the cask surface and current handling methods are used. To reduce these exposure levels, alternate handling methods are being developed and demonstrated. The production nature of cask receiving operations suggests commercial robotics be incorporated into a remote handling system to reduce predicted worker exposure to acceptable levels, while maintaining or increasing throughput. The first phase of cask handling system development culminated in a proof-of-principle test demonstrating the feasibility of performing cask receiving and unloading operations in a remote and ...
1985-04-21
British Library Electronic Table of Contents (United Kingdom)
Many hoarding rodents use burrows not only for dwelling and protection from natural enemies, but also for food storage. However, little is known how burrows used by scatter-hoarding animals influence their foraging behaviors. In addition, handling time for a given food item has a fundamental impact on hoarding strategies of these hoarding animals: food items with longer handling time are more likely to be hoarded due to increasing predation risk because the animals spend more time outside their burrows if they consumed such food. By providing with two types of artificial burrows (aboveground vs. underground) and two types of food items (i.e. seeds) with contrasting handling times, we investigated how burrow condition and handling time co-influence hoarding strategies of a key scatter-hoard...
2010-01-01
Signal simulator for the calibration of eddy current probes
Energy Technology Data Exchange (ETDEWEB)
This paper describes a signal simulator which is designed to calibrate eddy current probes. By using simultaneously an excitation coil and an electrically conducting plane, the simulator can emulate signals which correspond to spot welds with different flaws. The presence of a conducting plane allows a wide variation of the amplitude and phase of the excitation coil voltage during the calibration of a probe. A mathematical model for the simulator is derived and used to study the variation of the impedance change upon the parameters of the probe. Numerical computation shows that the impedance change depends in an important way on the frequency of the excitation coil current.
1994-01-01
Continuous measurement of blast-furnace coke moisture
International Nuclear Information System (INIS)
After presenting the advantages of applying neutron moisture gages to the continuous measurement of blast-furnace coke moisture and explaining the factors influencing the measurement accuracy, the necessity of calibrating these devices under flow conditions and the encountered difficulties are discussed. Using statistical methods it has been observed that the main source of calibration errors is the sampling phase. Based on results of mathematical processing, a new calibration method with higher performance - compared with the earlier ones - is proposed. This method allows to achieve high accuracy in a relatively short time. (author).
Energy Technology Data Exchange (ETDEWEB)
Calibration system for spot welding robots has been developed. The purpose of this system is to reduce the misalignment of tool center point (TCP) generated when teaching data made by off-line system is input to an actual robot. After the factor of the misalignment was analyzed, the relation between a main factor and the misalignment was modeled. In addition, the model was verified on experiment. The achievement of the accuracy requirement and practical use in the site was confirmed by the result of the verification. (author)
1999-04-01
Tests of the ONERA Calibration Models in Three Transonic ...
... changes in the wing shock/ separation patterns throughout ... to Reynolds number and tunnel flow quality before ... AGARD Conference Proceedings No ...
1976-11-01
Energy Technology Data Exchange (ETDEWEB)
The major problem of measurement of a power spectral density (PSD) distribution of surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments, which tends to distort the PSD at higher spatial frequencies. The special mathematical properties of binary pseudo-random patterns make them an ideal basis for developing MTF calibration test surfaces. Two-dimensional binary pseudo-random arrays (BPRAs) have been fabricated and used for the MTF calibration of the MicroMap{trademark}-570 interferometric microscope with all available objectives. An investigation into the effects of fabrication imperfections on the quality of the MTF calibration and a procedure for accounting for such imperfections are presented.
2010-03-31
Satellite Calibration Data. Annual Data Report - 1977
... in Taylor and Williamson.* Most satellite sensors cannot be ... The coordinates of the rocket Ii ... I - Incoming Global Radiant Flux between 0.285 and ...
1979-08-01
Salt Lake City shows hot and cold spots - NASA ... - Science@NASA
Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...
Group deal delay solution has fit 42 psec with 2.4% outliers. Group delay ambiguities with spacing 3.9 ns (another world record!) were successfully resolved. ...
International Nuclear Information System (INIS)
When exposure-calibrated ionization chambers are used to calibrate megavoltage X-ray and electron beam therapy machines, the calibration factor can be divided into a chamber-dependent and a chamber-independent component. Until recently, only the chamber-independent part, which has been derived theoretically, has been used; the chamber-dependent component has been ignored. Recent experimental and theoretical considerations, however, have indicated that the dependent component must be taken into account and can affect the calibration by as much as 4%. The calibration can change due to (i) the thickness of the chamber wall, (ii) the chamber wall composition, i.e. whether the chamber is constructed of air-equivalent material, or tissue- or water-equivalent material, and (iii) the size of the chamber changing the displacement factor. Theoretical and experimental evidence indicates that ...
DMSP Special Sensor Microwave/Imager Calibration ...
... Using a weighted linear regression on randomly selected coincident SSM/I-buoy pairs from each of the climate m codes, it was possible to produce ...
2011-05-14
Comparison of methods to determine accurate dose calibrator activity measurements
UK PubMed Central (United Kingdom)
BackgroundIn nuclear medicine, liquid radiopharmaceuticals for diagnostic or therapeutic purposes are administered to patients by using various types of syringes with different volumes....Full Text Available
Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF
Energy Technology Data Exchange (ETDEWEB)
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.
2004-04-01
Calibrating Cosmological Chronometers: White Dwarf Masses ...
... The second scenario is limited by the age of our Galaxy such that the lowest-mass WD that could be formed via single star evolution is ~0.47 M ...
2011-05-14
BIG BEAR SOLAR OBSERVATORY - NASA Technical Report Server (NTRS)
replacing the KDP crystal, and introducing computer programs for accumulation of an almost unlimited number of frames. The calibration procedure using solar ...
AGARD Flight Test Techniques Series. Volume 1. Calibration ...
... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...
1983-09-01
British Library Electronic Table of Contents (United Kingdom)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experi...
2007-01-01
Industrial experience with an intelligent AC/DC standard
Energy Technology Data Exchange (ETDEWEB)
AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.
1989-04-01
Gamma spectrometry calibrations with natural radioactive materials
Energy Technology Data Exchange (ETDEWEB)
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).
1996-02-01
Gamma spectrometry calibrations with natural radioactive materials
International Nuclear Information System (INIS)
Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).
Determination of efficiency curves of germanium detectors using natural radioactive materials
International Nuclear Information System (INIS)
Efficiency calibration curves for different densities and geometries are necessary for activity determination of various environmental samples. Commercially available standards or natural radioactive materials are used for calibration. Potassium compounds are especially suitable, since they can be mixed with unknown samples. It is possible to determine efficiency curve and unknown activity of sample knowing "4"0 K activity. (author).
Energy Technology Data Exchange (ETDEWEB)
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable ...
2011-03-14
Energy Technology Data Exchange (ETDEWEB)
A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test ...
2010-07-26
Energy Technology Data Exchange (ETDEWEB)
The objective of this study is to develop a method to aid in the selection of an overburden handling system in surface coal mining. The selection procedure consists of three major parts. The first part is aimed at rating the equipment's potential to perform the environmental protection related activities and then integrating this rating into the system selection process. The second part is an engineering analysis of the design of pit layouts and the operation of alternative overburden handling systems. The third part consists of a cost and sensitivity analysis of alternative systems on different mining situations. Specifically, the work includes: (1) a Delphi study to determine the magnitude of the environmental impacts and to quantify the relationship between mining practices and environmental remedies, (2) a scoring model to set up an index of the relative capability of equipment to do the environmental protection related jobs, (3) ...
1985-01-01
Remote handling equipment to robotics - Development within BNFL
International Nuclear Information System (INIS)
There are two major distinct activities involved with reprocessing of nuclear fuel. They are: a) Mechanical handling of the fuel in the head end plants; and b) chemical dissolution and separation of unused fuel, useful by-products and waste products. Plants and facilities associated with the former include significant remote handling equipment that is designed for handling of fuel for normal production processes. These equipment are selected and designed to meet the design throughput of the plant taking into consideration ease of their operation and maintenance in conjunction with statutory regulations on safety and operator dose uptake. Nevertheless, during the life of the plant, there are instances when special equipment is called for to access part of the plant and undertake tasks such as inspection, maintenance and modification to improve the existing process. BNFL has much experience in the design and application of ...
1995-11-01
Circuit breaker lockout device
Energy Technology Data Exchange (ETDEWEB)
An improved lockout assembly for locking a circuit breaker in a selected off or on position is provided. The lockout assembly includes a lock block and a lock pin. The lock block has a hollow interior which fits over the free end of a switch handle of the circuit breaker. The lock block includes at least one hole that is placed in registration with a hole in the free end of the switch handle. A lock tab on the lock block serves to align and register the respective holes on the lock block and switch handle. A lock pin is inserted through the registered holes and serves to connect the lock block to the switch handle. Once the lock block and the switch handle are connected, the position of the switch handle is prevented from being changed by the lock tab bumping up against a stationary housing portion of the circuit breaker. When the lock pin installed, an ...
1992-01-01
Energy Technology Data Exchange (ETDEWEB)
This document presents a detailed schedule for the implementation of the strategy for managing defense remote-handled (RH) transuranic (TRU) waste. The baseline management strategy was defined in the Defense Remote-Handled Transuranic Waste Cost/Schedule Optimization Study and is summarized in this document. Also included are revised RH TRU waste inventory projections, current site management plans, a list of key decision points and milestones, and a discussion of uncertainties associated with management of RH TRU waste. The plans are summarized in a detailed schedule diagram and in an RH TRU waste work off diagram. 9 refs., 5 figs., 4 tabs.
1988-01-01
International Nuclear Information System (INIS)
... 2.1 Yellow Cake Specification3 Storage and Handling 2.2 Dissolution 2.3
1976-09-06
Offshore drilling rig with enclosed work area
Energy Technology Data Exchange (ETDEWEB)
In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.
1987-12-01
NASA 11x:/,3 '/t.z- - NASA Technical Reports Server
_! Packaging, Cleanlines_, Preparation j Handling ..... 35. 'I. 40. WATER ................ , ......... Sterile, High Purity, Ethylene Glycol-Water Solutions. Requirement For . ...
D-11. The Contractor shall pack and mark all hardware deliverable under this ... Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD 2073-2, ...
UK PubMed Central (United Kingdom)
Approximately 65% of PSI structures report some type of ligand(s) that is bound in the crystal structure. Here, a description is given of how such ligands are handled and analyzed at the JCSG and a...Full Text Available
Interactive computer programs in sequence data analysis.
UK PubMed Central (United Kingdom)
We present interactive computer programs for the analysis of nucleic acid sequences. In order to handle these programs, minimum computer experience is sufficient. The nucleotide sequence of the human...Full Text Available
1982-01-11
British Library Electronic Table of Contents (United Kingdom)
The National Food and Nutrient Analysis Program (NFNAP) was implemented in 1997 to update and improve the quality of food composition data maintained by the United States Department of Agriculture (USDA). NFNAP was designed to sample and analyze frequently consumed foods in the U.S. food supply using statistically rigorous sampling plans, established sample handling procedures, and qualified analytical laboratories. Methods for careful handling of food samples from acquisition to analysis were developed to ensure the integrity of the samples and subsequent generation of accurate nutrient values. The infrastructure of NFNAP, under which over 1500 foods have been sampled, mandates tested sample handling protocols for a wide variety of foods. The majority of these foods were categorized into ...
2010-01-01
CRC manual of nuclear medicine: Procedures. Fourth Edition
Energy Technology Data Exchange (ETDEWEB)
This book discusses the procedures applied for the clinical nuclear medicine laboratory. The procedures are presented as proven guidelines. The chapters are included on quality assurance, radionuclide handling, and radiation safety.
1983-01-01
An Investigation of Rotorcraft Stability-Phase Margin Requirements ...
allowed an initial assessment of ADS-33 handling quality requirements for an aircraft of this ...... then executing 180 or 360 degree turns in an attempt to ...
APOD: 2009 May 26 - Whirlpool Galaxy Deep Field
Clicking on the picture will download the highest resolution version available. Whirlpool Galaxy Deep Field Credit & Copyright: Jon Christensen Explanation: Follow the handle...
2011-10-07
APOD: 2002 July 10 - M51: Cosmic Whirlpool
on the picture will download the highest resolution version available. M51: Cosmic Whirlpool Credit & Copyright: Tony and Daphne Hallas Explanation: Follow the handle of the Big...
2011-10-07
Sep 19, 2005 ... within a sealed tube to control the environment to which a sample mounts are better suited to handling the very small crystal is exposed. ...
Dating divergences in the Fungal Tree of Life: review and new analyses.
The collection of papers in this issue of Mycologia documents considerable improvements in taxon sampling and phylogenetic resolution regarding the Fungal Tree of Life. The new data will stimulate new attempts to date divergences and correlate events in fungal evolution with those of other organisms. Here, we review the history of dating fungal divergences by nucleic acid variation and then use a dataset of 50 genes for 25 selected fungi, plants and animals to investigate divergence times in kingdom Fungi. In particular, we test the choice of fossil calibration points on dating divergences in fungi. At the scale of our analysis, substitution rates varied without showing significant within-lineage correlation, so we used the Langley-Fitch method in the R8S package of computer programs to estimate node ages. Different calibration points had a dramatic effect on estimated divergence dates. The estimate for the age of the Ascomycota/Basidiomycota ...
Calibration free laser-induced breakdown spectroscopy of oxide materials
Energy Technology Data Exchange (ETDEWEB)
The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse ...
2010-08-15
Particle Flow at CMS and the ILC
This thesis describes hadron reconstruction at the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN, Geneva. The focus is on the particle flow reconstruction of these objects. This thesis revisits the subject of the CMS calorimeters' non-linear response to hadrons. Data from testbeam experiments conducted in 2006 & 2007 is compared with simulations and substantial differences are found. A particle flow calibration to correct the energy response of the testbeam data is evaluated. The reconstructed jet response is found to change by ~ 5% when a data-driven calibration is used in place of the calibration derived from simulation. Collision data taken at the early stage of CMS' commissioning is also presented. The hadron response in data is determined to be compatible with testbeam results presented in this thesis. This thesis also details the use of neural networks to improve the energy ...
2010-01-01
Low-range flowmeters for use with vacuum and leak standards
Energy Technology Data Exchange (ETDEWEB)
Vacuum pressure standards of the orifice-flow type require known gas flows of 10/sup -6/ mol/s (10/sup -2/ atm cm/sup 3//s at 0 /sup 0/C) and less. Known gas flows can also be used to calibrate ''standard'' leaks by comparing the pressures generated when flows from the leak and the flowmeter are alternately passed through a constant conductance. Two constant-pressure, piston displacement flowmeters developed at the National Bureau of Standards are described that can generate flows between 10/sup -6/ and 10/sup -10/ mol/s with an estimated uncertainty of 0.8% to 2%. Comparisons of the flowmeters with alternate calibration techniques, and repeated low-range leak and vacuum gauge calibrations, have been used to confirm the estimated uncertainty and random errors of the flowmeter.
1987-05-01
Experimental compliance calibration for the mixed-mode bending (MMB) specimen
Energy Technology Data Exchange (ETDEWEB)
A novel method to control the mixed-mode bending (MMB) specimen is presented. By maintaining a constant opening, or Mode 1, displacement rate, stable delamination growth is achieved for all mixed-mode ratios. A constant-opening displacement rate is achieved by attaching a second displacement transducer to the hinges of the specimen. The test machine is then controlled externally by the second displacement transducer. By achieving stable delamination growth and monitoring the opening displacement, an experimental compliance calibration may be derived for the Modes 1 and 2 parts. This new approach to control the test and determine the experimental compliance calibration, overcomes the potential inaccuracies of the previously used beam theory expressions to determine compliance and to separate the modal values of G.
1997-12-31
Energy Technology Data Exchange (ETDEWEB)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
2010-10-15
International Nuclear Information System (INIS)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is presented and measurement ...
2010-10-01
Calibration of solid state nuclear track detector CR-39 for radon measurements
Energy Technology Data Exchange (ETDEWEB)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
2007-07-01
Calibration of solid state nuclear track detector CR-39 for radon measurements
International Nuclear Information System (INIS)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
Analysis of installation damage tests for LRFD calibration of reinforced soil structures
British Library Electronic Table of Contents (United Kingdom)
North American design codes are now committed to the development of load and resistance factor design (LRFD) for reinforced soil structures including internal stability limit states. Reliability-based analysis is required to carry out these calibrations. A framework for LRFD calibration has been proposed by the writers that requires bias statistics for load and resistance terms for each limit state function. In this paper the formulation of the limit state for reinforcement tensile rupture is developed and the component strength-reduction bias statistics identified. The paper describes how to compute bias statistics from project-specific installation damage trials for use in reliability-based design for the reinforcement rupture limit state or using data from multiple sources for LRFD cali...
2011-01-01
A refined lack-of-fit statistic to calibrate pesticide fate models for responsive systems
British Library Electronic Table of Contents (United Kingdom)
BACKGROUND: Calibration by inverse modelling was performed with the MACRO transport and fate model using long-term (>10 years) drainflow and isoproturon (IPU) data from western France. Two lack-of-fit (LOF) indices were used to control the inverse modelling: sum of squares (SS) and an alternative statistic called the vertical-horizontal distance integrator (VHDI), which is designed to account for offsets in observed and predicted arrival times of peak IPU concentration. With these data, SS was artificially inflated because it is limited to comparison of predicted and observed IPU concentrations that are concurrent in time. The LOFs were used along with the index of agreement (d) and the correlation coefficient (r) to ascertain the fit of the calibrated models. RESULTS: Predicted arrival ti...
2009-01-01
such as public utilities, waste disposal sites, large energy dependent facilities including factories, institutions ( ...provides immediate identification of PCB wastes, informs company officials of any special handling or disposal techniques ...provides immediate identification of PCB wastes, informs company officials of any special handling or disposal techniques
Energy Technology Data Exchange (ETDEWEB)
This Radioactive and Mixed Waste Management Plan for the Hazardous Waste Handling Facility at Lawrence Berkeley Laboratory is written to meet the requirements for an annual report of radioactive and mixed waste management activities outlined in DOE Order 5820.2A. Radioactive and mixed waste management activities during FY 1994 listed here include principal regulatory and environmental issues and the degree to which planned activities were accomplished.
1995-01-01
International Nuclear Information System (INIS)
This book contains the proceedings of the International Topical Meeting on Remote Systems and Robotics in Hostile Environments. It is organized under the following sessions: Worldwide Applications Overview; Operating Mobile Systems; Sensors and Control Systems; Space Applications; Reactor Operations and Surveillance; Remote Equipment for Hazardous Operations; Future Mobile System; Mining and Construction Operations; Special Applications; Hot Cell Applications; Processing; Reactor Operations and Maintenance; Decontamination and Waste Handling; Remote Handling Development and Demonstration.
The periodic mode is analyzed together with two conventional boundary handling modes for particle swarm. By providing an infinite space that comprises periodic copies of original search space, it avoids possible disorganizing of particle swarm that is induced by the undesired mutations at the boundary. The results on benchmark functions show that particle swarm with periodic mode is capable of improving the search performance significantly, by compared with that of conventional modes and other algorithms.
2005-01-01
Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer
Energy Technology Data Exchange (ETDEWEB)
This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.
1991-05-08
Circuit breaker lock out assembly
Energy Technology Data Exchange (ETDEWEB)
A lock out assembly for a circuit breaker which consists of a generally step-shaped unitary base with an aperture in the small portion of the step-shaped base and a roughly S shaped retaining pin which loops through the large portion of the step-shaped base. The lock out assembly is adapted to fit over a circuit breaker with the handle switch projecting through the aperture, and the retaining pin projecting into an opening of the handle switch, preventing removal.
1983-05-18
Automated remote positioning and examination of FFTF reactor power characterization dosimeters
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.
1981-05-04
An outline of the fuelling machine electrical instrumentation and controls
International Nuclear Information System (INIS)
An outline of the instrumentation and control systems associated with fuelling machines is given. The control systems such as hydraulic system, oil hydraulic system, electric control system and the remote control systems have been discussed in detail. The difference between RAPP and MAPP fuel handling control systems has been explained. A computer based system for the Narora fuel handling control system is also discussed. (S.K.K.).
Waste Handeling Building Conceptual Study
Energy Technology Data Exchange (ETDEWEB)
The objective of the ''Waste Handling Building Conceptual Study'' is to develop proposed design requirements for the repository Waste Handling System in sufficient detail to allow the surface facility design to proceed to the License Application effort if the proposed requirements are approved by DOE. Proposed requirements were developed to further refine waste handling facility performance characteristics and design constraints with an emphasis on supporting modular construction, minimizing fuel inventory, and optimizing facility maintainability and dry handling operations. To meet this objective, this study attempts to provide an alternative design to the Site Recommendation design that is flexible, simple, reliable, and can be constructed in phases. The design concept will be input to the ''Modular Design/Construction and Operation Options ...
2000-11-06
International Nuclear Information System (INIS)
The main problems arising in decommissioning nuclear-powered submarines (NPS) relate to choosing a concept of handling reactor compartments followed by handling technology development. Reactor compartments (RC) are characterized with extremely space-saving or integral layout of large-size power equipment and systems, restricted access for dismantling, high radiation dose rates in a number of bays of RC. The above RC features pose a problem to find optimum option of RC utilization which on the one hand would be the most cost efficient, and the safest as possible on the other, i.e. dose commitments of personnel involved should be minimum, and effect on population and environment should be negligible. The main radiation factors specifying safety in RC handling at any decommissioning stage are as follows: (1) total radioactivity integrated in reactor facility (RF); (2) distribution of this radioactivity through RF equipment and ...
1996-03-10
UNS YMSCP QA support task: Quarterly technical progress report, January 1, 1991--June 30, 1991
Energy Technology Data Exchange (ETDEWEB)
This report describes a quality assurance program plan for the Yucca Mountain Project. Aspects of the plan include: document control, equipment maintenance and calibration, process control, audits, computer software, and inspections. (CBS)
1991-07-30
THE OGIP FORMAT FOR 2-D (IMAGE) POINT SPREAD FUNCTION ... - NASA
tial/angular spreading of incident photons from a point source caused by the instrument (de- .... Filter. CDTP0001= 'DATA. ' / Type of calibration. CCNM0001= '2D_PSF ' ... the final resolution of sigma=0.5 arcmin in all energy bands. ...
We report on the spectral cross-calibration results of the Konus-Wind, the Suzaku/WAM, and the Swift/BAT instruments using simultaneously observed gamma-ray bursts (GRBs). This is the first attempt to use simultaneously observed GRBs as a spectral calibration source to understand systematic problems among the instruments. Based on these joint spectral fits, we find that 1) although a constant factor (a normalization factor) agrees within 20% among the instruments, the BAT constant factor shows a systematically smaller value by 10-20% compared to that of Konus-Wind, 2) there is a systematic trend that the low-energy photon index becomes steeper by 0.1-0.2 and Epeak becomes systematically higher by 10-20% when including the BAT data in the joint fits, and 3) the high-energy photon index agrees within 0.2 among the instruments. Our results show that cross-calibration based on joint spectral analysis is an important step to ...
2010-01-01
Measurements of Spectral Characteristics of Swimmer Targets ...
... 3.0 Radar Measurements 3-1 3. 1 Spectral Density Measurements 3-2 3. 1. 1 System Calibration 3-3 ... 3. 1 SPECTRAL DENSITY MEASUREMENTS ...
1974-05-01
Los Alamos second-generation system for passive and active neutron assays of drum-size containers
International Nuclear Information System (INIS)
We describe in a comprehensive fashion the Los Alamos second-generation system for passive and active neutron assays of drum-size containers. The developmental history of this 7-year project is presented with emphasis on the pulsed active neutron technique (differential dieaway), which has achieved milligram levels of assay sensitivity for both plutonium and uranium wastes. We describe in detail the matrix effects for both passive and active neutron assays. We present in a thorough fashion our novel approach to achieving comprehensive corrections for these matrix effects using measurements made during the assays. We develop a matrix correction formalism based on separate neutron absorption and moderator indices determined from these measurements. These are presented as a series of analytic functions fitted to the data. Absolute calibrations and calibration standards are discussed, as is a practical means (pink drum measurements) of achieving ...
1972-09-17
Granite Countertops and Radiation | Radiation Protection | US EPA
... Top of page Testing Radiation coming from granite countertops results from natural radioactive material in the granite. Identifying the presence and concentration of radioactive elements in granite requires expensive and sophisticated portable instruments or laboratory equipment. These instruments and equipment require proper calibration, and interpretation of ...
Exploding Bridgewire Electrical System Test Unit.
The object of the test was to develop a method to field test the Exploding Bridgewire (EBW) System for proper functioning prior to use. Two basic designs were conceived and tested. The first design using a two element spark gap and a calibrated fuse link ...
1964-01-01
Energy Technology Data Exchange (ETDEWEB)
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table ...
2000-03-01
Chalk Point Cooling Tower Project: Chalk Point Meteorological Station Report. Volume II.
This report documents the operation, maintenance, calibration, data acquisition and data reduction at the Chalk Point Meteorological Station for the period November 15, 1978 through November 15, 1979. Climatological data summaries for each month and calib...
1979-01-01
COSPIN-ANISOTROPY TELESCOPE for ULY - PDS - NASA
To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...
Energy Technology Data Exchange (ETDEWEB)
The major problem of measurement of a power spectral density (PSD) distribution of the surface heights with surface profilometers arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF tends to distort the PSD at higher spatial frequencies. It has been suggested [Proc. SPIE 7077-7, (2007), Opt. Eng. 47 (7), 073602-1-5 (2008)] that the instrumental MTF of a surface profiler can be precisely measured using standard test surfaces based on binary pseudo-random (BPR) patterns. In the cited work, a one dimensional (1D) realization of the suggested method based on use of BPR gratings has been demonstrated. Here, we present recent achievements made in fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. The 2D BPRAs were used as standard test surfaces for 2D MTF calibration of the MicromapTM-570 interferometric microscope with all available objectives. ...
2009-07-07
Artery phantoms for intravascular optical coherence tomography: healthy arteries
UK PubMed Central (United Kingdom)
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of...Full Text Available
Residential vertical geothermal heat pump system models: Calibration to data
Energy Technology Data Exchange (ETDEWEB)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was tuned to better match the measured data from the site. These tuned models were then interconnected to form the system model. The system model was then exercised in order to demonstrate its capabilities.
1997-12-31
Residential Vertical Geothermal Heat Pump System Models: Calibration to Data:
Energy Technology Data Exchange (ETDEWEB)
A detailed component-based simulation model of a geothermal heat pump system has been calibrated to monitored data taken from a family housing unit located at Fort Polk, Louisiana. The simulation model represents the housing unit, geothermal heat pump, ground heat exchanger, thermostat, blower, and ground-loop pump. Each of these component models was 'tuned' to better match the measured data from the site. These tuned models were then interconnect to form the system model. The system model was then exercised in order to demonatrate its capabilities.
1997-06-01
Parameter optimization of a planar BEGe detector using Monte Carlo simulations
International Nuclear Information System (INIS)
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.
2010-11-21
PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.
2008-01-01
Synopsis of moisture monitoring by neutron probe in the unsaturated zone at Area G
Energy Technology Data Exchange (ETDEWEB)
Moisture profiles from neutron probe data provide valuable information in site characterization and to supplement ground water monitoring efforts. The neutron probe precision error (reproducibility) is found to be about 0.2 vol% under in situ field conditions where the slope in moisture content with depth is varying slowly. This error is about 2 times larger near moisture spikes (e.g., at the vapor phase notch), due to the sensitivity of the probe response to vertical position errors on the order of 0.5 inches. Calibrations were performed to correct the downhole probe response to the volumetric moisture content determined on core samples. Calibration is sensitive to borehole diameter and casing type, requiring 3 separate calibration relations for the boreholes surveyed here. Power law fits were used for calibration in this study to assure moisture content results greater than zero. Findings in the ...
1997-12-31
Calibration of the Capintec CRC-712M dose calibrator for "1"8F
International Nuclear Information System (INIS)
Primary standardisation was performed on a solution of "1"8F using the 4#pi##beta#-#gamma# coincidence counting efficiency-tracing extrapolation method with "6"0Co used as a tracer nuclide. The result was used to calibrate the ANSTO secondary standard ionisation chamber which is used to disseminate Australian activity standards for gamma emitters. Using the secondary activity standard for "1"8F, the Capintec CRC-712M dose calibrator at the Australian National Medical Cyclotron (NMC) Positron Emission Tomography (PET) Quality Control (QC) Section was calibrated. The dial setting number recommended by the manufacturer for the measurement of the activity of "1"8F is 439. In this work, the dial setting numbers for the activity measurement of the solution of "1"8F in Wheaton vials were experimentally determined to be 443+/-12, 446+/-12, 459+/-11, 473+/-15 for 0.1, 1, 4.5 and 9ml solution volumes, respectively. The uncertainties ...
2006-04-01
Use of information sources by family physicians: a literature survey.
UK PubMed Central (United Kingdom)
Analysis of the use of information sources by family physicians is important for both practical and theoretical reasons. First, analysis of the ways in which family physicians handle information may...Full Text Available
1995-01-01
Understanding Skill in EVA Mass Handling - NASA Technical Report ...
pedel supl3od" surfcoe. U => ut::_oer (torso segment or shoulder. 13oint),. L => lower. (legs]. m-I. => mediolatercl a_is re. Doo_,. s-i => ...
The search for stable prognostic models in multiple imputed data sets
UK PubMed Central (United Kingdom)
BackgroundIn prognostic studies model instability and missing data can be troubling factors. Proposed methods for handling these situations are bootstrapping (B) and Multiple imputation...Full Text Available
The physics of automatic letter sorting
The astronomical number of letters handled by the Post Office makes automatic sorting technology essential. Key roles are played by the postcode system and an ink-jet printer that has been developed to use phosphorescent inks.
1988-07-01
The Brain Database: A Multimedia Neuroscience Database for Research and Teaching
UK PubMed Central (United Kingdom)
The Brain Database is an information tool designed to aid in the integration of clinical and research results in neuroanatomy and regional biochemistry. It can handle a wide range of data types including...Full Text Available
1989-11-08
UK PubMed Central (United Kingdom)
VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available
2000-01-01
SECTION D - PACKAGING AND MARKING - NASA
D.1 PACKAGING AND MARKING (NASA 18-52.210-75) (SEP 1990) ... Packaging, Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD- 2073-2, ...
Religion as a Natural Phenomenon
...same sort of handle ? religious that we have on global warming or energy policy or ...other words my claim is that we need to study religion the way we study global warming and all the other really serious phenomena on this planet ...
Programs Automate Complex Operations Monitoring - NASA
Mar 2, 2011 ... CCT's software is capable of simultaneously handling incoming ... has been using CCTK to automate its remote control rocket cryogenic fueling systems. ... seismic, infrared, and proximity sensor data with auto-tracking ...
International Nuclear Information System (INIS)
With the exception of some minerals, the specific activity of natural radioactive material is below 370 Bq/g, their handling thus not being subject to authorization or the duty of reporting according to section 4 para. 2 of the Radiological Protection Ordinance. Moreover, there is required no handling license for prospecting, mining and processing of radioactive minerals; they are subject to the procedures for the plans of operation of the mining laws of the Federal States. License-free handling of natural radioactive material may result in the production of radioactive waste, the disposal of which must be authorized according to sect. 47 of the Radiological Protection Ordinance if the specific activity exceeds the free amounts of column 4 in Table IV of Appendix IV by a factor of 10"-"4/g. This inconsistency is discussed by means of the following examples: (1) fly ash and slag from coal power plants, (2) flue dust from ...
1980-05-01
UK PubMed Central (United Kingdom)
Organophosphates and carbamates (OPs/CMs) are known for their acetylcholinesterase inhibiting character. A cross-sectional study of pesticide handling practices and self-perceived symptoms of acute...Full Text Available
2011-01-01
Packaging and ... - server-mpo.arc.nasa.gov Default Home - NASA
... the provisions of NASA Handbook (NHB) 6000.1, Requirements for Packaging, Handling, and Transportation, and/or MIL-STD-2073-1 and MIL-STD-2073-2, ...
Outpatient percutaneous coronary intervention: Ready for prime time?
UK PubMed Central (United Kingdom)
Outpatient practice after percutaneous coronary intervention (PCI) is gaining momentum due to constantly optimizing results. Furthermore, the availability of limited beds to handle the large volume...Full Text Available
2007-10-01
UK PubMed Central (United Kingdom)
Policies and regulations in the current health care environment have impacted the manner in which patient data - especially protected health information (PHI) - are handled in the clinical and...Full Text Available
2008-02-20
Gene expression analysis of interferon ? in laser capture microdissected cervical epithelium
UK PubMed Central (United Kingdom)
Optimal sample handling techniques for tissue preparation and storage, RNA extraction and quantification, and target gene detection are crucial for reliable gene expression analysis. Methods...Full Text Available
2008-10-01
FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling ...
1987-09-01
Design and safety evaluation of radioactive gas handling and storage in the FFTF
International Nuclear Information System (INIS)
During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and CAPS systems are described and certain ...
1976-06-13
Comparative Evaluation of Three Commercial Systems for Nucleic Acid Extraction from Urine Specimens
UK PubMed Central (United Kingdom)
A nucleic acid extraction system that can handle small numbers of specimens with a short test turnaround time and short hands-on time is desirable for emergent testing. We performed a comparative validation...Full Text Available
2005-09-01
Clustering gene expression data with a penalized graph-based metric
UK PubMed Central (United Kingdom)
BackgroundThe search for cluster structure in microarray datasets is a base problem for the so-called "-omic sciences". A difficult problem in clustering is how to handle data with...Full Text Available
Cargo Projects Milestones, Schedules and Status Summary
subject to a learning curve which should help to lessen the user's time at KSC. An MMSE Payload Handling Fixture has ...... (F4.I ASSlUN IASILlM.ny.CTC I ...
Secretariat of the Basel Convention United Nations Office at Geneva ...such as public utilities, waste disposal sites, large energy dependent facilities including factories, institutions (hospitals, ...it provides immediate identification of PCB wastes, informs company officials of any special handling or disposal techniques
UK PubMed Central (United Kingdom)
Recent health care policies and regulations have impacted the manner in which patient data – especially protected health information (PHI) – are handled in both the clinical...Full Text Available
2007-06-01
29 CFR 1926.602 - Material handling equipment.
...Pneumatic-tired earth-moving haulage equipment (trucks, scrapers, tractors...Pneumatic-Tired Earthmoving Haulage Equipment. An employer may, of course...pneumatic-tired earthmoving haulage equipment, is suspended pending...
2009-07-01
Waste management considerations for fusion power reactors
International Nuclear Information System (INIS)
To estimate the waste management needs of a fusion power reactor, a scheme for handling radioactive waste from a fusion plant has been devised. The handling scheme proceeds with radioactive waste, primarily from blanket replacement, being stored on-site; waste in cooled and shielded casks is then isolated off-site; finally, the materials are recycled. Using activities and component lifetimes supplied by designers, several conceptual fusion power reactors have been analyzed and their waste streams compared to fission reactors with regard to total activity, specific activity, and lifetimes of activity.
Waste management considerations for fusion power reactors
To estimate the waste management needs of a fusion power reactor, a scheme for handling radioactive waste from a fusion plant has been devised. The handling scheme proceeds with radioactive waste, primarily from blanket replacement, being stored on-site; waste in cooled and shielded casks is then isolated off-site; finally, the materials are recycled. Using activities and component lifetimes supplied by designers, several conceptual fusion power reactors have been analyzed and their waste streams compared to fission reactors with regard to total activity, specific activity, and lifetimes of activity.
1978-02-01
Remote on-board coal quality sensing techniques in coal cutting and handling systems
Energy Technology Data Exchange (ETDEWEB)
A review of the literature was undertaken to determine the potential for development of instrumentation for on-board remote sensing of coal quality. This review report acts as an inventory of commercially available techniques being tested or under development, particularly in the areas of the cutting horizon measurement methods associated with longwall mining equipment and coal/waste monitoring techniques in coal handling systems. While technology is available which can discriminate rocks from coal on a conveyor belt, the literature indicates that this hardware has yet to be adapted to continuous surface mining machines. 23 refs., 18 figs.
1987-09-01
Remote handling and robotics at the BNFL Sellafield reprocessing plant
International Nuclear Information System (INIS)
As a direct result of its interest in the use of robotics within active plants, British Nuclear Fuels Ltd. (BNFL) has adopted a positive attitude toward both national and European initiatives in this area. During the early operation of the Sellafield reprocessing plant, the process vessels and cell voids were monitored using simple pole and camera combinations. In 1985, BNFL embarked on the provision of a series of machines intended to satisfy the advancing needs for inspection while increasing the level of expertise within the company in this important area. DIMAN 1, DIMAN 2, RODMAN, REPMAN, and RAFFMAN remote handling and robotic machines are described.
1990-11-11
R D for the storage, transport, and handling of coal-based fuels
Energy Technology Data Exchange (ETDEWEB)
The product of several advanced physical coal cleaning processes is a dry, ultrafine coal (DUC), in the order of 10 microns mean mass diameter. To utilize this fuel commercially, cost-effective, environmentally safe systems must be provided for the storage, transport, and handling of this finely divided form of fuel. The objective of the project described herein is the development of total logistics systems for DUC, including experimental verification of key features. The systems to be developed will provide for safe, economic, and environmentally protective storage and delivery of DUC for residential, commercial, and industrial uses. 20 figs.
1991-01-01
Handling of sodium for the FFTF
Based on the High Temperature Sodium Facility (HTSF) experience and the extensive design efforts for FFTF, procedures are in place for the unloading of the tank cars and for the fill of the FFTF reactor. Special precautions have been taken to provide safe handling and to accommodate contingencies in operation. These contingencies include special protective suits allowing personnel to enter and correct conditions arising from fill operations in the course of moving 7.71 x 10/sup 5/ kg (1.7 x 10/sup 6/ lbs) of sodium from the tank cars into the reactor vessel and its loop system.
1978-06-01
Computer control of fuel handling activities at FFTF
International Nuclear Information System (INIS)
The Fast Flux Test Facility near Richland, Washington, utilizes computer control for reactor refueling and other related core component handling and processing tasks. The computer controlled tasks described in this paper include core component transfers within the reactor vessel, core component transfers into and out of the reactor vessel, remote duct measurements of irradiated core components, remote duct cutting, and finally, transferring irradiated components out of the reactor containment building for off-site shipments or to long term storage. 3 refs., 16 figs.
1985-09-08
Applications of infrared and Raman spectroscopy in industry
Energy Technology Data Exchange (ETDEWEB)
There have been many recent explosive advances in both IR and Raman spectroscopy which have developed in response to industrial problems of increasing complexity. Probably the biggest factor in these advances has been computerization, which has contributed not only to substantial improvements in data handling but to enormous gains in sensitivities of analyses as well. In this paper numerous examples of Raman and IR applications in industry are given using many of these recent advances, including in-situ techniques, microprobe analyses, unusual combinations of instruments - i.e., hyphenated methods - and new sample handling techniques. The bright future of FT-IR and Raman spectroscopy is also briefly discussed.
1986-07-01
On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of ...
2010-10-01
International Nuclear Information System (INIS)
The effect of measurement geometry on the determination of the activity of solutions containing "1"2"5I for use in brachytherapy applications has been investigated for 5 mL plastic syringes and 2 mL conical glass dose vials as a function of filling mass. New dial settings for the syringes over a filling mass range of 1 to 3 g have been determined to be 497#+-#8 and 469#+-#8 (expanded, k=2, uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively, with any effect due to the filling mass lying within the uncertainty in the activity calibration. A filling mass effect was observed in the dose vials, causing a 10.5% reduction in the chamber response from a 2 g filling mass to 1 g. Dial settings at 2 g were experimentally found to be 143#+-#2 and 135#+-#2 (expanded uncertainties) for the NIST Capintec CRC-12 and Capintec CRC-35R, respectively. The appropriate dial settings for the same vials with a 1 g filling mass were found to be 120#+-#2 and ...
2002-07-01
Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code
Energy Technology Data Exchange (ETDEWEB)
In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A Monte Carlo study of ...
1998-12-01
Energy Technology Data Exchange (ETDEWEB)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
2007-12-15
International Nuclear Information System (INIS)
Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS) has been proposed several years ago as an approach for quantitative analysis of Laser-Induced Breakdown Spectroscopy spectra. Recently developed refinement of the spectral processing method is described in the present work. Accurate quantitative results have been demonstrated for several metallic alloys. However, the degree of accuracy that can be achieved with Calibration-Free Laser-Induced Breakdown Spectroscopy analysis of generic samples still needs to be thoroughly investigated. The authors have undertaken a systematic study of errors and biasing factors affecting the calculation in the Calibration-Free Laser-Induced Breakdown Spectroscopy spectra processing. These factors may be classified in three main groups: 1) experimental aberrations (intensity fluctuations and inaccuracy in the correction for spectral efficiency of a detection system), 2) inaccuracy ...
2007-12-01
[Comparison of wound morphology following gunshots by machine guns and sub-machine guns].
Automatic weapons such as machine guns and submachine guns are found in the German-speaking region only in special army and police units and appear accordingly rarely in homicides, suicides and accidents. In the following, the findings in two cases of death with the use of machine and submachine guns are presented. The first case was a fatal accident during shooting on a training area (current machine gun of the German army, calibre 7.62 x 51 mm), the second case was a killing during a physical conflict (submachine gun MP 40 from World War II, calibre 9 x 19 mm). In the case with the machine gun autopsy disclosed typical entry holes corresponding to the calibre, but unusually large exit wounds with tissue bridges in the wound ground, measuring 4 x 2.5 cm in diameter. By contrast, the second case (submachine gun) showed "normal" entry and exit wounds. The differences are mainly caused by deviating ballistic data of the ...
The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs
We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with Swift's X-Ray (XRT) ...
2009-01-01
Online processing in the ALICE DAQ The detector algorithms
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...
2010-01-01
Metrology measurement capabilities
Energy Technology Data Exchange (ETDEWEB)
Since 1958, the AlliedSignal Federal Manufacturing and Technologies (FM and T) Metrology Department has developed measurement technology and calibration capability in four major areas of measurement: mechanical; environmental, gas, liquid; electrical (D.C., A.C., RF/microwave); and optical and radiation. The capabilities developed include unique capabilities in many areas of measurement and engineering expertise to develop measurement techniques and resolve measurement problems in these major areas. FM and T Metrology was established in 1958 to provide a measurement base for the Department of energy`s Kansas City Plant. The Metrology Engineering Department provides the expertise to develop measurement capabilities for virtually any type of measurement which falls into the broad areas listed above. The engineering staff currently averages almost 16 years of measurement experience. A strong audit function has been developed to provide a means to evaluate the ...
1997-06-01
Energy Technology Data Exchange (ETDEWEB)
Versatility of the TRNSYS software program, the ease with which new components can be incorporated into the software, and its application to simulate heat pump systems was discussed. A case history was described in which the package, augmented by the addition of several recent large-scale heat pump projects, was used in calibrating a residential geothermal heat pump system at a military housing project in Fort Polk, LA. The project involved retrofitting over 4000 air source heat pumps with geothermal heat pumps in an energy savings performance contract. The calibration of the component models led to a system model which accurately predicts the performance of the geothermal heat pump. The lessons learned from the calibration exercise were used to help to predict the energy savings from one of the electric feeders at the base which serves some 200 of the 4000+ apartments. Energy savings estimates within one per cent of the ...
1997-11-01
International Nuclear Information System (INIS)
A highly reliable screening method was developed for the determination of lead in tin plated layers and tin-bismuth plated layers. The contents of lead in the layers of the various samples were determined by inductively coupled plasma optical emission spectrometry. The calibration curve for lead in the tin and tin-bismuth plated layers by using WD-XRF exhibited linear correlation from 130 #mu#g/g to 2070 #mu#g/g. Calibration curve of lead normalized with Pb-L#alpha#/Sn-K#alpha# intensity was more linear, and this method was possible to evaluate very small sample. The calibration curve for lead in the tin plated layers by using ED-XRF was good linearly, but it for lead in the tin-bismuth plated layers was affected by Pb-L#alpha# spectrum and Bi-L#alpha# spectrum overlap each other. It was effective for decreasing affect of Bi-L#alpha# spectrum by using curve fitting method. (author)
2009-03-01
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Energy Technology Data Exchange (ETDEWEB)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
2010-01-15
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
International Nuclear Information System (INIS)
The aim of this paper is offering a critical review of Calibration-Free Laser-Induced Breakdown Spectroscopy (CF-LIBS), the approach of multi-elemental quantitative analysis of LIBS spectra, based on the measurement of line intensities and plasma properties (plasma electron density and temperature) and on the assumption of a Boltzmann population of excited levels, which does not require the use of calibration curves or matrix-matched standards. The first part of this review focuses on the applications of the CF-LIBS method. Quantitative results reported in the literature, obtained in the analysis of various materials and in a wide range of experimental conditions, are summarized, with a special emphasis on the departure from nominal composition values. The second part is a discussion of the simplifying assumptions which lie at the basis of the CF-LIBS algorithm (stoichiometric ablation and complete atomization, thermal equilibrium, homogeneous ...
2010-01-01
International Nuclear Information System (INIS)
Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)
2010-02-01
The KCAL VERA 22 GHz calibrator survey
We observed at 22 GHz with the VLBI array VERA a sample of 1536 sources with correlated flux densities brighter than 200 mJy at 8 GHz. One half of target sources has been detected. The detection limit was around 200 mJy. We derived the correlated flux densities of 877 detected sources in three ranges of projected baseline lengths. The objective of these observations was to determine the suitability of given sources as phase calibrators for dual-beam and phase-referencing observations at high frequencies. Preliminary results indicate that the number of compact extragalactic sources at 22 GHz brighter than a given correlated flux density level is twice less than at 8 GHz.
2011-01-01
On the problem of magnitude calibration of palaeoearthquakes
British Library Electronic Table of Contents (United Kingdom)
Some factors affecting the accuracy of magnitude calibration of palaeoearthquakes are discussed. The general problem is illustrated by two case studies. First, the 2003 strong earthquake in the Altai region (Russia-Mongolia border), which has generated co-seismic surface faulting is considered. An analysis is conducted to determine how accurately its magnitude could be defined after 2000 years based on surface faulting parameters, retrieved when future palaeoearthquake studies are launched. This example demonstrates that accurate evaluation of magnitude is possible if specific regional seismotectonic features are taken into account and surface faulting parameters are measured over a dense grid. Next, the Muya earthquake that occurred in the Baikal seismic region in 1957 is studied with res...
2011-01-01
Groundtruth approach to accurate quantitation of fluorescence microarrays
Energy Technology Data Exchange (ETDEWEB)
To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.
2000-12-01
Enamel-Calibrated Lamellar Bone Reveals Long Period Growth Rate Variability in Humans
British Library Electronic Table of Contents (United Kingdom)
Abstract Mammalian teeth exhibit incremental structures representing successive forming fronts of enamel at varying time scales, including a short daily increment called a cross striation and a long period called a stria of Retzius, the latter of which, in humans, occurs on average every 8-9 days. The number of daily increments between striae is called the repeat interval, which is the same period as that required to form one increment of bone, i.e. the lamella, the fundamental - if not archetypal - unit of bone. Lamellae of known formation time nevertheless vary in width, and thus their measures provide time-calibrated growth rate variability. We measured growth rate variability for as many as 6 years of continuously forming primary incremental lamellar bone from midshaft femur histologic...
2011-01-01
Demonstration experiments of volume measurement technique for large scale input accountancy tank
International Nuclear Information System (INIS)
Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)
2000-12-07
Comparison of constitutive models for plastic-bonded explosives
British Library Electronic Table of Contents (United Kingdom)
A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The task of designing high performance X-ray optical systemsrequires the development of sophisticated X-ray scattering calculationsbased on rigorous information about the optics. One of the mostinsightful approaches to these calculations is based on the powerspectral density (PSD) distribution of the surface height. The majorproblem of measurement of a PSD distribution with an interferometricand/or atomic force microscope arises due to the unknown ModulationTransfer Function (MTF) of the instruments. The MTF characterizes theperturbation of the PSD distribution at higher spatial frequencies. Here,we describe a new method and dedicated test surfaces for calibration ofthe MTF of a microscope. The method is based on use of a speciallydesigned Binary Pseudo-random (BPR) grating. Comparison of atheoretically calculated PSD spectrum of a BPR grating with a spectrummeasured with the grating provides the desired calibration of theinstrumental MTF. The ...
2007-07-25
British Library Electronic Table of Contents (United Kingdom)
Derivative spectrophotometry and bivariate calibration algorithm were used for study of run of photooxidation of levomepromazine hydrochloride (LV). The actual concentrations of LV and its main degradation product levomepromazine sulphoxide (LV-SO) were calculated using data provided by applied methods. The direct reading of absorbance values at 302nm and 334nm were employed for quantification of LV and LV-SO, respectively, in the case of bivariate method. The derivative spectrophotometric method is based on transformation of zero-order spectra into first derivative. The values of first derivative at 334nm were used for quantification of LV while at 278nm for assay of LV-SO. The obtained quantitative data were applied for investigation of kinetics of photodegradation of LV.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
1984-01-01
Open test assembly (OTA) shear demonstration testing work/test plan
Energy Technology Data Exchange (ETDEWEB)
This document describes the development testing phase associated with the OTA Shear activity and defines the controls to be in place throughout the testing. The purpose of the OTA Shear Program was to provide equipment that is needed for the processing of 40 foot long, sodium wetted, irradiated core components previously used in the FFTF reactor to monitor fuel and materials tests. There are currently 15 of these OTA test stalks located in the Test Assembly Conditioning Station (TACS) inerted vault. These need to be dispositioned for a shutdown mission to eliminate this highly activated, high dose inventory prior to turnover to the ERC since they must be handled by remote operations. These would also need to be dispositioned for a restart mission to free up the vault they currently reside in. The waste handling and cleaning equipment in the J33M Cell was designed and built for the handling of reactor components up to the ...
1998-07-16
VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:
0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...
Thermal NDE method for thermal spray coatings
Energy Technology Data Exchange (ETDEWEB)
This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.
1982-01-01
International Nuclear Information System (INIS)
Phenomenological accountancy of quanta-electrodynamic corrections by means of introduction into multielectron theory of short-term potential, the parameters whereof are calibrated in such a way that provides for correct reproduction of the Lamb shift of the 1s-orbital energy for a correspondingly selected effective charge is developed by example of d-line of Na-like multicharged ions.
Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer
International Nuclear Information System (INIS)
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
1986-01-01
Replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory
Energy Technology Data Exchange (ETDEWEB)
The DOE-Idaho Operations Office (DOE-ID) has prepared an environmental assessment (EA) on the replacement of the Idaho National Engineering Laboratory Health Physics Instrumentation Laboratory at the Idaho National Engineering Laboratory (INEL). The purpose of this project is to replace the existing Health Physics Instrumentation Laboratory (HPIL) with a new facility to provide a safe environment for maintaining and calibrating radiation detection instruments used at the Idaho National Engineering Laboratory. The existing HPIL facility provides portable health physics monitoring instrumentation and direct reading dosimetry procurement, maintenance and calibration of radiation detection instruments, and research and development support-services to the INEL and others. However, the existing facility was not originally designed for laboratory activities and does not provide an adequate, safe environment for calibration ...
1995-05-01
Regulatory experience on safety system instrument uncertainty of Wolsong units
International Nuclear Information System (INIS)
This paper presents the regulatory experience gained from Wolsong Units 2,3 and 4 - Special Safety System Instrumentation Uncertainty for Trip Setpoint and Allowable Values. The equipment diversity method for the defense against common mode failure was applied to the transmitters of shutdown system number 2. However the Units experienced an unexpected drift problem with which the performance did not meet the Technical Specification (Tech Spec) Surveillance Requirements (SR). Discussed are the background, status and corrective actions, regulatory positions and issues to be solved for the drift problem. It was an instrument uncertainty methodology that the designer of safety system should have shown when the drift problem occurred. For deeper understanding of the problem, we present the background of Tech Spec SR for setpoints in Korean PWR and in CANDU reactors. The Setpoint Verification Test(SVT) and Calibration Test(CT) shall be achieved by recording sufficient ...
2001-05-01
International Nuclear Information System (INIS)
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
Radial distribution of bonded fission gas in mixed carbide fuel pins
International Nuclear Information System (INIS)
The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).
1979-01-01
Mission Science Calibration and Validation Plan - SMAP
Nov 16, 2010 ... In situ observations are usually made point-wise and the problem in using ...... also discussion of adaptive filtering in Section 4.1.2 of the L4_SM ...... L2-SR -265 SMAP shall provide a Level 1C radar sigma-0 product ...
Influencing factors on ESR dose assessment in irradiated chicken legs
Energy Technology Data Exchange (ETDEWEB)
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
1996-12-31
Ground water modelling in artificial recharge projects
International Nuclear Information System (INIS)
Decision-making is strongly based on modelling in two of our water supply projects concerning artificial ground water. The model used is a 2-dimensional flow and transport model using the element method. Due to sharp variations in Finnish soils, the modelling process is based on careful and detailed evaluation of basic hydrogeological data before and during model calibration.
1991-05-09
Evaluation of Dry Chemicals by Photoacoustic Imaging
In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.
1992-10-01
Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis
International Nuclear Information System (INIS)
Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.
1994-06-01
Colorimetric porous indicator of carbon dioxide
Energy Technology Data Exchange (ETDEWEB)
This paper investigates the spectral characteristics of three-dimensionally porous carbon dioxide indicators based on a porous silicate glass and phenolphthalein. The absorption spectra of the original solutions of phenolphthalein in alkaline and acid solutions are shown. The solutions were acidified by bubbling CO/sub 2/ through an alkaline phenolphthalein solution. The authors have succeeded in producing a reversible colorimetric adsorption indicator for carbon dioxide which after proper calibration enables the CO/sub 2/ content of an atmosphere to be estimated quantitatively.
1986-03-01
Characterization of Adaptive Optics at Keck Observatory
Energy Technology Data Exchange (ETDEWEB)
In this paper, the adaptive optics (AO) system at Keck Observatory is characterized. The AO system is described in detail. The physical parameters of the lenslets, CCD and deformable mirror, the calibration procedures and the signal processing algorithms are explained. Results of sky performance tests are presented: the AO system is shown to deliver images with an average Strehl ratio of up to 0.37 at 1.59 {micro}m using a bright guide star. An error budget that is consistent with the observed image quality is presented.
2003-07-24
Applications of Bonner sphere detectors in neutron field dosimetry
Energy Technology Data Exchange (ETDEWEB)
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
1983-09-01
Applications of Auger spectroscopy and ESCA to the study of thin films formed on metals
International Nuclear Information System (INIS)
Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.
1979-05-23
An ultrasonic goniometer for surface stress measurement
An instrument has been constructed for the measurement of residual stress in steel. If necessary, large objects can be examined in situ. An account is given of the principles and construction. A special stressing frame provides for calibration. An application to residual stress in gear blanks has established a systematic variation of surface stress with nickel content and confirmed the overall effect of the surface hardening treatment.
1978-09-01
An instrument for measuring spatial and time characteristics of sea agitation in coastal zones
Energy Technology Data Exchange (ETDEWEB)
Resistive analogous meters for spatial and time characteristics in ocean agitation are most often used in practical oceanography in coastal zones but are based on bridge circuits determined to have shortcomings in their linearity range. This shortcoming is eliminated in the circuit of an instrument developed in an oceanographic laboratory (IMIO, Vana). Principle and block circuits are indicated, and static calibration curves are presented as are the correlative functions in the frequency spectrums obtained with the help of sea agitation recorded at a fixed point and at a depth of 6 meters.
1981-01-01
International Nuclear Information System (INIS)
At Tarapur Atomic Power Station 3 and 4, 540 MWe Pressurised Heavy Water Reactors, core being large in size requires a continuous in core monitoring for local flux disturbances. Nearly 200 Self Powered Neutron Detectors (SPNDs) of the Straight Individually Replaceable (SIR) type are distributed in the reactor core. For purpose of reactor regulation and protection, cobalt SPNDs that have a prompt response for changes in power is used for in-core flux mapping, vanadium SPNDs that provide accurate measure of neutron flux, even though having slow response is used In core SPNDs are placed in Vertical Flux Units (VFU) and Horizontal Flux Units (HFUs). These SPNDs were to be replaced at regular intervals to meet the design intent. Cobalt SPNDs have dose rates of the order of 1000 Gy/h and the Mineral Insulated (MI) cables of Vanadium SPNDs have dose rates of the order of 100 Gy/h. So far 3 Cobalt SPNDs were removed from HFUs and are being stored in lead shielding inside spent fuel storage ...
2006-11-13
Process development for remote-handled mixed-waste treatment
Energy Technology Data Exchange (ETDEWEB)
The Oak Ridge National Laboratory (ORNL) is developing a treatment process for remote-handled (RH) liquid transuranic mixed waste governed by the concept of minimizing the volume of waste requiring disposal. This task is to be accomplished by decontaminating the bulk components so the process effluent can be disposed with less risk and expense. Practical processes have been demonstrated on the laboratory scale for removing cesium 137 and strontium 90 isotopes from the waste, generating a concentrated waste volume, and rendering the bulk of the waste nearly radiation free for downstream processing. The process is projected to give decontamination factors of 10{sup 4} for cesium and 10{sup 3} for strontium. Because of the extent of decontamination, downstream processing will be contact handled. The transuranic, radioactive fraction of the mixed waste stream will be solidified using a thin-film evaporator and/or microwave solidification system. ...
1990-01-01
Mechanisms of renal handling of lead
International Nuclear Information System (INIS)
The relative roles of glomerular filtration, tubular reabsorption and tubular secretion in lead handling were evaluated using renal clearance technique, stop-flow analysis, and renal lead accumulation. In addition, the effect of altering acid-base status on renal handling of Pb was determined. Clearance of ultrafilterable lead was measured in anesthetized dogs during infusion of "2"0"3Pb with small doses of carrier Pb(0.5 to 50 #mu#g/kg/h). Filterable lead concentration was estimated by in vitro ultrafiltration of non-anticoagulated plasma. Fractional excretion of Pb was calculated using creatinine clearance to estimate glomerular filtration rate. Dogs in acute metabolic acidosis had the lowest fractional excretion of ultrafilterable Pb (< 0.1); those in alkalosis had high fractional Pb excretion (0.75 to 2.5) while normal dogs were intermediate (0.1 to .4). The fractional excretion of Pb during metabolic alkalosis varied with the dose of Pb ...
Energy Technology Data Exchange (ETDEWEB)
The adaption of the Muster-VAwS (model ordinance on the handling of water endangering substances in plants and specialized facilities) in the ordinances of the different German states, means that the legislator has laid down concrete - technical and organizational - requirements concerning the handling of water-endangering substances for all plants. The present example of the systematic stocktaking of all environmentally relevant substances in the context of the operation of the pumped storage plants of Schluchseewerk AG, Freiburg, an the application of the model operating instructions for hydropower plants shall serve to illustrate two important aspects for the implementation of this extensive ordinance. (orig.) [Deutsch] Durch Umsetzung der Muster-VAwS (Muster-Verordnung ueber Anlagen zum Umgang mit wassergefaehrdenden Stoffen und Fachbetriebe) in entsprechende Laenderverordnungen wurden durch den Gesetzgeber konkrete Anforderungen, technisch ...
1998-08-01
Energy Technology Data Exchange (ETDEWEB)
Users of pesticides may have waste or surplus quantities or spills for disposal. One alternative is to deactivate the pesticide at the handling site by using a straightforward chemical reaction. This option can be practical for those who use relatively small quantities of a large variety of pesticides, for example, greenhouse workers, small farmers, and agricultural researchers. This paper describes practical on-site methods for the disposal of spills or small waste quantities of five commonly used pesticides, Diazinon, Chlorpyrifos, Iprodione, 2,4-D, and Captan. These have been tested in the laboratory for the rate of disappearance of the pesticide, the degree of conversion to nontoxic products, the nature and identity of the products, the practicality of the method, and the ease of reproducibility. Methods selected were shown to be safe for the operator, reliable, and reproducible. Greater than 99% of the starting material had to be reacted under reasonable ...
1996-12-31
REVIEW: Optical waveguide processors
An analysis is made of the basic principles and methods of construction of integrated optical circuits (IOC) for data processing, which are optical waveguide processors in the integrated form. A classification is provided of IOC in accordance with the nature of the input connections to optical components and in accordance with their intended function. An analysis is made of the current status of research and development of analog IOC for handling analog and digital signals, IOC for computing technology, and switching IOC. A detailed analysis is made of IOC with different functions in data processing: spectrum analyzers and correlators, analog-digital converters, circuits for identification of data sets and for encoding of signals, threshold and multistable circuits, logic and arithmetic units, and switching arrays. Descriptions are given of IOC for optically controlled data handling: bistable purely optical logic circuits, multivibrators, ...
1987-07-01
Multiprocessors and Asynchronous Event Handling in the Real-Time Specification for Java
British Library Electronic Table of Contents (United Kingdom)
The Real-Time Specification for Java (RTSJ) is silent on multiprocessor issues. It attempts not to preclude multiprocessor implementations but provides no direct support. Many areas of the RTSJ leave an implementation considerable freedom on how it provides the defined functionality. One such area is the asynchronous event handling (AEH) model. Events are fired and associated handlers are scheduled for execution in response; handlers have defined scheduling parameters and deadlines. The primary goal of the AEH model is to support a lightweight real-time concurrency model. Hence handlers, in general, do not have dedicated threads. Rather, the implementation is responsible for ensuring that all handlers meet their deadlines. Typically real-time threads are assigned to execute handlers by the...
2011-01-01
International Nuclear Information System (INIS)
Liquid radioactive waste treatment method of using evaporator was widely used from Kori 1 to Uljin 3 and 4, but a liquid radioactive waste treatment equipment that uses an ion exchange method instead of an evaporator was adopted aiming to minimize amount of radioactive waste and radiation exposure. However, the same equipment was introduced and applied for the first time in Korea and had experienced difficulties in securing credibility for the equipment and handling of liquid radioactive waste with inadequate data about performance and experience in operation and maintenance. In this study, examination, application and effect analysis was performed on the optimization measure for handling liquid radioactive waste of Yonggwang Nuclear Power Unit 5 and 6(YGN 5 and 6) that applies an ion exchange method
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
Conversion of Idaho National Engineering and Environmental Laboratory radioactive sodium-bearing waste into a single solid waste form by evaporation was demonstrated in both flask-scale and pilot-scale agitated thin film evaporator tests. A sodium-bearing waste simulant was adjusted to represent an evaporator feed in which the acid from the distillate is concentrated, neutralized, and recycled back through the evaporator. The advantage to this flowsheet is that a single remote-handled transuranic waste form is produced in the evaporator bottoms without the generation of any low-level mixed secondary waste. However, use of a recycle flowsheet in sodium-bearing waste evaporation results in a 50% increase in remote-handled transuranic volume in comparison to a non-recycle flowsheet.
2004-01-01
Energy Technology Data Exchange (ETDEWEB)
WELLOG is a system of programs developed at the Earth Science Laboratory to be used to digitize well logs and perform some analysis and plotting of the data. Multiple logs can be plotted side by side for correlation analysis and up to three logs can be plotted in a cross plot. Data entry and editing functions are also provided by the programs. This system of well log interpretation programs is presently operating on the University of Utah UNIVAC 1108 computer. Digitizing of well logs is accomplished by an old model CALMA (off-line) digitizer. Those parts of WELLOG that handle the digitized data tapes are extremely machine dependent. The parts of WELLOG that produce the plots and handle the data beyond the digitized data tape are more portable.
1980-03-01
A Laplacian approach to multi-oriented text detection in video.
In this paper, we propose a method based on the Laplacian in the frequency domain for video text detection. Unlike many other approaches which assume that text is horizontally-oriented, our method is able to handle text of arbitrary orientation. The input image is first filtered with Fourier-Laplacian. K-means clustering is then used to identify candidate text regions based on the maximum difference. The skeleton of each connected component helps to separate the different text strings from each other. Finally, text string straightness and edge density are used for false positive elimination. Experimental results show that the proposed method is able to handle graphics text and scene text of both horizontal and nonhorizontal orientation. PMID:20733217
2011-02-01
Energy Technology Data Exchange (ETDEWEB)
This report describes modelling where the hydrological modelling system MIKE SHE has been used to describe surface hydrology, near-surface hydrogeology, advective transport mechanisms, and the contact between groundwater and surface water within the SKB site investigation area at Laxemar. In the MIKE SHE system, surface water flow is described with the one-dimensional modelling tool MIKE 11, which is fully and dynamically integrated with the groundwater flow module in MIKE SHE. In early 2008, a supplementary data set will be available and a process of updating, rebuilding and calibrating the MIKE SHE model based on this data set will start. Before the calibration on the new data begins, it is important to gather as much knowledge as possible on calibration methods, and to identify critical calibration parameters and areas within the model that require special attention. In this project, the MIKE SHE ...
2007-11-15
International Nuclear Information System (INIS)
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the peak efficiency values derived from such measurements will be on the order of a few percent at best because ...
2001-06-17
Waveguide device and method for making same
Energy Technology Data Exchange (ETDEWEB)
A monolithic micromachined waveguide device or devices with low-loss, high-power handling, and near-optical frequency ranges is set forth. The waveguide and integrated devices are capable of transmitting near-optical frequencies due to optical-quality sidewall roughness. The device or devices are fabricated in parallel, may be mass produced using a LIGA manufacturing process, and may include a passive component such as a diplexer and/or an active capping layer capable of particularized signal processing of the waveforms propagated by the waveguide.
2007-08-14
The feasibility of closing the loop
Energy Technology Data Exchange (ETDEWEB)
Current European and the US experiences in waste management are reviewed in the perspective of sustainable development. This publication questions the validity of the current approach taken by the Germany at ``closing the loop`` based on the example of packaging and packaging waste. The product item focus of current German legislation is compared with Danish and US approaches that are based on an integrated policy which covers the whole of waste generation and handling and is not product/item oriented. 1 fig., 2 tabs.
1998-12-01
The Philadelphia Marriott: A convention center flagship hotel
Energy Technology Data Exchange (ETDEWEB)
This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.
1997-01-01
International Nuclear Information System (INIS)
Various diagnostics techniques for condition monitoring and life prediction of fluid power components and system are discussed. Though some of the techniques are very promising but may not be accepted because of increase in the instrumentation, it is planned to implement these techniques on various circuits of Fluid Power Lab for further improving and developing these for direct implementation in various fluid power circuits of power reactors. (author). 6 figs.
Energy Technology Data Exchange (ETDEWEB)
High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)
2008-05-15
Scientific data manipulation in a relational data-base system
Energy Technology Data Exchange (ETDEWEB)
Provided the user interface is well designed, extended relational algebra can be a powerful tool for handling scientific data. Its utility is greatly enhanced by the addition of attribute algebra to allow mathematical manipulation of field values. The paper reports on a development which, motivated by practical requirements, integrates features such as functions, vector data types, iteration, and conditional-attribute values into a relational data-base management system.
1986-07-01
Robotics: Growing maintenance option for utilities
International Nuclear Information System (INIS)
The use of robots in powerplants is an option that can no longer be ignored. Robots can reduce worker exposure to harmful environments and minimize downtime. As a result, electric utilities are using them more than ever. As robots become more widely accepted, more are being developed to handle an expanding variety of applications. This report begins with an overview of the use of robotics in the electric-utility industry; following that are sections detailing applications for nuclear plants, fossil-fired stations, and transmission and distribution facilities.
Resources | Environment Knowledge Hub
... MUNICIPAL SOLID WASTES (MANAGEMENT AND HANDLING) RULES, 2000 Plastic Bag ban in Dhaka City, Bangladesh Private Sector Participation in Municipal Solid Waste Management SKAT 2000 TECHNICAL GUIDELINES ON MUNICIPAL SOLID WASTE MANAGEMENT Hazardous Waste Management Unit, Environmental Pollution Control Division, Central Environmental Authority, Sri Lanka 2004 Subregional ...
Red mud and sands handling: New thoughts on an old problem
Energy Technology Data Exchange (ETDEWEB)
The alumina industry is facing worldwide a growing disposal problem. Red mud creates increasingly technical, economic and environmental problems. Available solutions are reviewed and an old idea using a new approach with pressurized disc or drum filters for red mud is herewith presented and submitted for consideration as a potential and prospective solution to the problem.
1996-10-01
International Nuclear Information System (INIS)
This standard describes requirements and provides guidelines for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear power plants. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storage, cleaning, constructing, erecting, installing, inspecting, testing, maintaining, repairing, initial fueling, refueling, and modifying.
International Nuclear Information System (INIS)
Requirements and guidelines are provided for the control of activities to be exercised during procurement of items and services which affect the quality of nuclear facilities. These requirements and guidelines apply to procurement activities for items and services such as designing, purchasing, fabricating, handling, shipping, storing, cleaning, constructing, erecting, installing, inspecting, texting, maintaining and modifying.
Proceedings, third international symposium on mine mechanization and automation
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under the following topics: machine control and automation; rock drilling; cutting and fragmentation; rock characterization, remote sensing and interface detection; artificial intelligence and mine monitoring systems; computer applications; mechanical excavators; material handling; surface and underground mining; innovative mining systems; new developments in mechanical miners; ground hazard detection and control; ground support; and extraterrestrial mining.
1995-12-31
Proceedings, international symposium on mine mechanization and automation
Energy Technology Data Exchange (ETDEWEB)
Papers are presented under the session headings: research in mechanical fragmentation; rock characterization, remote sensing and interface detection; monitoring, data transmission and communications; tunnel boring machines; minewide monitoring and expert systems for ground control; machine guidance; shaft and raise boring; automation of drilling equipment; machine automation and control; new developments in mechanical miners; materials handling; innovative mining systems; general minewide monitoring and expert systems; ground support; human factors; and extraterrestrial mining.
1991-01-01
Now try to explain network security
Overloaded transmission lines are only part of the problem. The ability of the network to carry power is also limited by the supply of reactive power and by frequency stability. Reactive power problems must be corrected in minutes, frequency stability problems in seconds. There is no way that market forces can handle these problems. Reactive power must be supplied to all long transmission and distribution lines to compensate for the loss of reactive volt-amperes - and resulting voltage drop - in the reactance along the line`s length. 7 figs.
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
A decision must be made regarding whether the United State`s stockpile of neptunium should be discarded into the waste stream or kept for the production of Pu-238. Although the cost of long term storage is not inconsequential, to dispose of the material means the closing of our option to maintain control over our Pu-238 stockpile. Within the Fuels and Materials Examination Facility at Hanford there exists a remotely operated facility that can be converted for neptunium storage. This paper describes the facility and the anticipated handling requirements.
1993-06-01
Multi-mode wavepath depth imaging for the SEG/EAGE salt model
Energy Technology Data Exchange (ETDEWEB)
Elastic depth imaging of both P-wave and S-wave prestack seismic reflection data is formulated as a degraded form of Kirchhoff migration known as Wavepath Migration (WM). Applications to the SEG/EAGE salt model show that the method is sufficiently versatile anti relaitively inexpensive. It handles S-wave data with at least the same accuracy as Pwave data when local mode conversions are removed. WM also provides an understanding of multi-mode illumination.
2003-01-01
Management buyouts in the coal industry - are they a viable proposition?
Energy Technology Data Exchange (ETDEWEB)
Following the management buy out (MBO) at British Coal`s Hatfield Colliery, a member of the Solicitors involved looks at some of the issues to be considered in coal industry MBO`s. British Coal should be notified, a business plan will be needed for handling venture capital and other issues, and warranties need negotiating.
1994-09-01
Mammography: limits of a technique
International Nuclear Information System (INIS)
Breast cancer represents today more than 30% of all cancers and is responsible for about 20% of deaths due to cancer. The potentialities of mammography have increased in recent years through improvements in equipment and methodologies. In this paper the conventional mammography using film and image intensifiers is compared with digital mammography. Digital mammography presents clear advantages in storage and handling of information. Also its higher sensitivity will lead to an earlier detection of anomalies and a decrease in the number of invasive exams and surgeries
2001-05-01
Hyperbolicity of Semigroup Algebras II
In 1996 Jespers and Wang classified finite semigroups whose integral semigroup ring has finitely many units. In a recent paper, Iwaki-Juriaans-Souza Filho continued this line of research by partially classifying the finite semigroups whose rational semigroup algebra %over a field of characteristic zero, contains a ${\\mathbb{Z}}$-order with hyperbolic unit group. In this paper we complete this classification by handling the case in which the semigroup is semi-simple.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
On handling nitric solutions in the glove box nitrous gases are formed that are sucked off via a heated activated charcoal filter and a catalyst cartridge containing e.g. the FG 590 H catalist (Degussa). By the activated charcoal the nitrous gases are reduced to N/sub 2/ and CO gas; the catalyst will oxidize CO to CO/sub 2/. The CO/sub 2/ obtained is discharged through an exhaust air filter in the glove box.
1980-02-21
Energy Technology Data Exchange (ETDEWEB)
The optimization of ethylene furnace operations using cfd-based simulations has been addressed. The optimization problems have been cast into various formulations: the Multidisciplinary feasible (MDF) approach, the All-At-Once (AAO) approach and the Individual discipline feasible (IDF) approach. These approaches mainly differ in their handling of the state equations as constraints, and hence some of the formulations place restrictions on the methods used to solve the state equations.
1999-08-31
Energy Technology Data Exchange (ETDEWEB)
The issues of the geothermal resource at Brady's Hot Springs are dealt with: the prospective supply of feedstocks to the ethanol plant, the markets for the spent grain by-products of the plant, the storage, handling and transshipment requirements for the feedstocks and by-products from a rail siding facility at Fernley, the probable market for fuel ethanol in the region, and an assessment of the economic viability of the entire undertaking.
1980-09-01
Energy Technology Data Exchange (ETDEWEB)
The paper describes a way to control methane that is almost self-sufficient. The Methane Buster extracts methane from longwall mines. The machinery can run virtually unattended and is fuelled by a small proportion of the methane that it extracts. The most popular model is the size of a car and weighs 3000 lbs. With pump inlet sizes varying from 6 to 24 ins. The pumps can handle up to 30,000 CFM. 3 photos.
2005-12-01
Design and procurement report for the FFTF fuel handling systems bottom-loading transfer cask
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) bottom-loading transfer cask (BLTC) system is designed to provide ex-vessel fuel transfers of irradiated reactor components between the reactor containment building and the LMFBR shipping cask in the reactor service building. This system is being procured from National Lead Industries, Wilmington, Delaware, under management of Aerojet Manufacturing Company.
1975-11-16
DISPOSAL OF SPENT SORBENT FROM DRY FGD (FLUE GAS DESULFURIZATION) PROCESSES
The report gives results of a study of sintering and leaching mechanisms of fly ash/spent sodium sorbent mixtures from a dry injection flue gas desulfurization (FGD) process. It includes an estimate of the economics of pelletizing and sintering to handle the fly ash and spent sor...
Continuous emission monitoring -- Data acquisition and handling system for management
Energy Technology Data Exchange (ETDEWEB)
This paper describes New York State Electric and Gas Corporation`s concept for a comprehensive, centrally located data system for management of their continuous emission monitoring systems (CEMS) data. The topics of the paper include the power system`s mix of generating units; data reporting requirements; data base management; nitrogen oxides compliance tracking; sulfur dioxide, nitrogen oxides, carbon dioxide and flow monitoring; and allowance tracking.
1995-09-01
Energy Technology Data Exchange (ETDEWEB)
This thesaurus contains the vocabulary used to index the Biomass Database maintained by the IEA Biomass Conversion Technical Information Service. The database, which is used to produce Biomass Abstracts, contains indexed and abstracted references to the published literature relating to biomass energy including cultivations, harvesting, materials handling, conversion techniques, environmental aspects and economics.
1984-10-01
International Nuclear Information System (INIS)
Large-scale decommissioning of Russian nuclear-powered submarines (NPS) and their utilization prospects gave rise to numerous complicated scientific and technical, as well as economic, problems. Problems of handling of radioactive equipment from the reactor compartments (RC) are among the vital ones, arousing a growing concern with the public. Without solution of the problems the processes of NPS utilization can not be considered completed. It involves potential hazard, for the environment both from NPS being paid up (temporal on-float storage) with unloaded spent nuclear fuel (SNF), and RC, cut from submarine hull, containing highly radioactive equipment and materials but no SNF. Diverse variations of the concept of reactor compartment handling of NPS subject to, utilization are possible, but, in principle, there are essentially two variants: (1) RC utilization directly in the course of NPS utilization, envisaging removal of radioactive ...
1996-03-10
UK PubMed Central (United Kingdom)
Resistance to the extended-spectrum cephalosporins can occur in Salmonella species via the production of extended-spectrum and AmpC β-lactamases. We describe human infections...Full Text Available
2003-10-01
API Report/LOOP (Louisiana Offshore Oil Port) startup will ease crude import handling problems
A description of LOOP covers the single point mooring (SPM) system; the offshore pipelines connecting each SPM to the pumping platform; the offshore platform complex, a pumping platform and a control platform; the onshore pipelines; and the Clovelly Dome storage terminal.
1979-01-01
A vision for Berlin and the Transrapid; Eine Vision fuer Berlin und den Transrapid
Energy Technology Data Exchange (ETDEWEB)
This paper demonstrates how maglev technology solves the classic problem of integrating two airports in a metropolitan area. So far, this has never been attempted because the mode of transportation that could handle this challenge effectively had not been invented yet. This also means that maglev technology is no longer 'the solution in search of a problem'. (orig.)
2005-07-01
A harvesting and handling system for sweet sorghum
Energy Technology Data Exchange (ETDEWEB)
Total and net energies used harvesting 30-cm billets at 8 t/h were 1 and 0.3 kW x h/t, respectively. Harvested crop had 4% leaves, a 70% mass fraction of billets 30-40 cm long, and a 49/sup 0/ angle of repose. A self-unloading forage wagon with beaters and controls metered billets at 1.5 t/h to feed a juice-expression mill.
1983-12-01
West Siberian basin hydrogeology - regional framework for contaminant migration from injected wastes
Energy Technology Data Exchange (ETDEWEB)
Nuclear fuel cycle activities of the former Soviet Union (FSU) have resulted in massive contamination of the environment in western Siberia. We are developing three-dimensional numerical models of the hydrogeology and potential contaminant migration in the West Siberian Basin. Our long-term goal at Pacific Northwest Laboratory is to help determine future environmental and human impacts given the releases that have occurred to date and the current waste management practices. In FY 1993, our objectives were to (1) refine and implement the hydrogeologic conceptual models of the regional hydrogeology of western Siberia developed in FY 1992 and develop the detailed, spatially registered digital geologic and hydrologic databases to test them, (2) calibrate the computer implementation of the conceptual models developed in FY 1992, and (3) develop general geologic and hydrologic information and preliminary hydrogeologic conceptual models relevant to the more detailed ...
1994-05-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
1998-10-01
Energy Technology Data Exchange (ETDEWEB)
Energy savings performance contracting (ESPC) is now receiving greater attention as a means of implementing large-scale energy conservation projects in housing. Opportunities for such projects exist for military housing, federally subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers), to name a few. Accurate prior (to construction) estimates of the energy savings in these projects reduce risk, decrease financing costs, and help avoid post-construction disputes over performance contract baseline adjustments. This paper demonstrates an improved method of estimating energy savings before construction takes place. Using an engineering model calibrated to pre-construction energy-use data collected in the field, this method is able to predict actual energy savings to a high degree of accuracy. This is verified with post-construction energy-use data from a geothermal heat pump ESPC at Fort Polk, Louisiana. This method also allows ...
1998-01-01
Type Ia supernova science 2010-2020
In the next decade Type Ia supernovae (SNe Ia) will be used to test theories predicting changes in the Dark Energy equation of state with time. Ultimately this requires a dedicated space mission like JDEM. SNe Ia are mature cosmological probes --- their limitations are well characterized, and a path to improvement is clear. Dominant systematic errors include photometric calibration, selection effects, reddening, and population-dependent differences. Building on past lessons, well-controlled new surveys are poised to make strides in these areas: the Palomar Transient Factory, Skymapper, La Silla QUEST, Pan-STARRS, the Dark Energy Survey, LSST, and JDEM. They will obviate historical calibrations and selection biases, and allow comparisons via large subsamples. Some systematics follow from our ignorance of SN Ia progenitors, which there is hope of determining with SN Ia rate studies from 0 2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The use of capacitance sensors for measuring phase concentrations in two-phase flow has gained popularity in recent years. In designing such sensors, there are many issues which must be considered in order to optimize performance: two-phase flow regime, permittivity of the phases, duct geometry, electrical shielding, desired spacial resolution of film thickness, and temperature variation in the flow field. These design issues are discussed and are used to optimize the design of a capacitance sensor which is used to measure vapor volume fraction in annular, two-phase vertical upflow and downflow in a square duct. The sensor was tested and implemented in a 12.7 mm square duct mounted in a flow boiling facility containing FC-72, a low permittivity dielectric fluid ({epsilon}{sub r} = 1.75). Using analytical modeling, an adjustable-length, parallel-plate design was developed and refined to achieve good sensitivity to flow conditions. The sensor output was calibrated ...
1995-12-31
The Schenberg spherical antenna: status report
International Nuclear Information System (INIS)
Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new ...
2009-09-14
Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully to the pharmaceutical ...
2002-04-15
Local cardiac glucose utilization (LCarGU) was quantified in the rat heart according to the Sokoloff model and local cardiac blood flow (LCarBF) according to the /sup 14/C-iodoantipyrine method. For quantitative autoradiography calibration curves for heart slices were performed. They differed from the brain calibration curves by 8%. The lumped constant was 0.377 in isolated working hearts. LCarGU and LCarBF could then be quantified in awake rats. At different locations mean LCarGU of different hearts varied from 85 to 200 ..mu..moles/100g/min and mean LCarBF from 390 to 831 ml/100g/min. The ratio subendocardial/subepicardial glucose utilization or blood flow was not systematically different from 1. The results indicate that glucose can be an important fuel in the heart of the awake rat, although its contribution to overall metabolism varies from animal to animal.
1986-03-05
Performance testing of selected types of electronic personal dosimeters used in Sudan
International Nuclear Information System (INIS)
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
2010-12-01
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is expected that these ...
2006-05-01
Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry
International Nuclear Information System (INIS)
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and remote area by using well ...
1977-11-01
Wireless sensor networks can revolutionize soil ecology by providing measurements at temporal and spatial granularities previously impossible. This paper presents a soil monitoring system we developed and deployed at an urban forest in Baltimore as a first step towards realizing this vision. Motes in this network measure and save soil moisture and temperature in situ every minute. Raw measurements are periodically retrieved by a sensor gateway and stored in a central database where calibrated versions are derived and stored. The measurement database is published through Web Services interfaces. In addition, analysis tools let scientists analyze current and historical data and help manage the sensor network. The article describes the system design, what we learned from the deployment, and initial results obtained from the sensors. The system measures soil factors with unprecedented temporal precision. However, the deployment required device-level programming, sensor ...
2007-01-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-05-10
Determination of reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR
The theory of a method of determination of reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mockup of a liquid-metal fast breeder reactor (LMFBR) and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments, the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mockup, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies to approximately 30 dollars subcritical. These experiments verified for the first time the predictions of theory that could be tested in the measurements. This method has ...
1978-04-01
Binary mixtures of dipyrone and pitophenone hydrochloride are assayed by zero-crossing second- and third-derivative spectrophotometry and by ratio-spectra first- and second-derivative spectrophotometry. In the first method, calibration plots are linear at 266.5 and 302.5 nm (dipyrone, second derivative), and 257 and 286 nm (pitophenone second derivative) and 242 and 278.3 nm (dipyrone third derivative), and 228.5 and 300 nm (pitophenone, third-derivative). By the second method, lines of regression are linear at 235 and 262 nm (dipyrone, first derivative), and 229.5 and 288.5 nm (pitophenone, first-derivative), and 249.7 and 268 nm (dipyrone, second derivative), and 280.5 and 300 nm (pitophenone, second-derivative). In all methods calibration curves follow the Beer's law up to 40 microg/ml of each drug. LOD and LOQ values were calculated. The developed derivative spectrophotometric methods were applied to laboratory mixtures and to vials for ...
2003-10-15
Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers
Energy Technology Data Exchange (ETDEWEB)
We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a ...
2008-01-16
Energy Technology Data Exchange (ETDEWEB)
The task of designing high performance X-ray optical systems requires the development of sophisticated X-ray scattering calculations based on rigorous information about the optics. One of the most insightful approaches to these calculations is based on the power spectral density (PSD) distribution of the surface height. The major problem of measurement of a PSD distribution with an interferometric and/or atomic force microscope arises due to the unknown Modulation Transfer Function (MTF) of the instruments. The MTF characterizes the perturbation of the PSD distribution at higher spatial frequencies. Here, we describe a new method and dedicated test surfaces for calibration of the MTF of a microscope. The method is based on use of a specially designed Binary Pseudo-random (BPR) grating. Comparison of a theoretically calculated PSD spectrum of a BPR grating with a spectrum measured with the grating provides the desired calibration of the ...
2007-08-01
Energy Technology Data Exchange (ETDEWEB)
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
2009-07-15
International Nuclear Information System (INIS)
In this work, the Calibration-Free approach for Laser-Induced Breakdown Spectroscopy (CF-LIBS) was applied for the first time to radially resolved spectra emitted by a laser-induced plasma. The radial profiles of plasma temperature and electron number density were used to calculate the local relative concentration of the elements of interest. We analyzed a set of profiles of the local spectral emission coefficient obtained previously by means of spatial deconvolution of the spectra from a copper-based alloy (Cu 93, Fe 5, Mn 1, Ni 1 wt.%) laser-induced plasma. A spatially integrated spectrum of the same plasma was also analyzed for comparison purpose. The relative abundance of the minor components Fe, Mn and Ni was calculated. The results obtained from the central region of the plasma were closer to the nominal concentrations than those obtained from the spatially integrated spectrum. However, an increasing deviation was observed towards the plasma edge. It is ...
2009-07-01
Energy Technology Data Exchange (ETDEWEB)
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO{sub 2} interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-{mu}m device characteristics, such as V{sub th} and I{sub dsat}, for which the differences between simulation and experiment less than 5 %.
2005-02-15
International Nuclear Information System (INIS)
We developed a new systematic calibration procedure which was applied to the prediction of the diffusivity, the segregation, and transient enhanced diffusion (TED) of an indium impurity. The TED of the indium impurity was studied using four different experimental conditions. Although indium is susceptible to TED, rapid thermal annealing (RTA) is effective in suppressing the TED effect and maintaining a steep retrograde profile. Like boron impurities, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients much less than 1 at the Si/SiO_2 interface. In contrast to boron, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed procedure was validated by using secondary ion mass spectrometry (SIMS) data and by using the 0.13-#mu#m device characteristics, such as V_t_h and I_d_s_a_t, for which the differences between simulation and experiment less than 5 %.
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
Verification, calibration, and validation (VCV) of Computational Fluid Dynamics (CFD) codes is an essential element of the code development process. The exact manner in which code VCV activities are planned and conducted, however, is critically important. It is suggested that the way in which code validation, in particular, is often conducted--by comparison to published experimental data obtained for other purposes--is in general difficult and unsatisfactory, and that a different approach is required. This paper describes a proposed methodology for CFD code VCV that meets the technical requirements and is philosophically consistent with code development needs. The proposed methodology stresses teamwork and cooperation between code developers and experimentalists throughout the VCV process, and takes advantage of certain synergisms between CFD and experiment. A novel approach to uncertainty analysis is described which can both distinguish between and quantify ...
1995-07-01
Yucca Mountain Task 4, Final report FY 1993
Energy Technology Data Exchange (ETDEWEB)
Four major projects at UNRSL have been supported by NWPO-Neotectonics Yucca Mountain Task 4 funds during the last year: (1) Operation and analysis of data from the UNRSL microearthquake network at Yucca Mountain. (2) Continued operation, maintenance, and calibration of three broadband stations. Limited data analysis was also initiated. (3) Continued review by Dr. Brune of documents and literature related to seismic hazard and tectonics of the Yucca Mountain region. (4) Testing of noise levels in boreholes.
1993-09-30
Energy Technology Data Exchange (ETDEWEB)
In the last two years, the VDMA work group 'Functional security' compiled a qualitative and quantitative procedure for the determination and evaluation of turbo-machine specific risks. With the calibrated risk graph for turbo-machines the requirements (Safety Integrity Level SIL) to the protective functions for turbo-machines (steam turbines, gas turbines, generators and compressors) were determined. With consideration of the legislation, the work group compiled a recommendation for the renewal and/or reconstruction of protective functions with old facilities.
2010-07-01
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Response of track-etch dosemeters to environmental radon
Energy Technology Data Exchange (ETDEWEB)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
1988-01-01
Reliable dates for the last 50.000 years; Des dates fiables pour les 50 000 dernieres annees
Energy Technology Data Exchange (ETDEWEB)
The accuracy of the carbon 14 dating method is dependent on the fluctuations of carbon 14 in the atmosphere over long periods of time. Fossil corals that are dated by both carbon 14 and uranium-thorium methods allows the setting of calibration curves for the carbon 14 method for the last 50.000 years. The uranium-thorium method is based on the measurement of the ratio of 2 isotopes: thorium 230 and uranium 234 that are both present in the decay chain of uranium 238. (A.C.)
2004-03-01
Radon measurements in dwellings using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
1984-01-01
Primary standardization of {sup 242} Am radioactive sources
Energy Technology Data Exchange (ETDEWEB)
The procedure followed by the Laboratorio de Metrologia Nuclear in Sao Paulo, Brazil, for the standardization of {sup 242g} Am is described. The calibration system was composed of a 4 {pi} gas-flow proportional counter coupled to a pair of NaI(Tl) crystals operating in coincidence. The samples were produced by irradiating dried aliquots of {sup 241} Am with thermal and epithermal neutrons at the IEA-R1 research reactor. The efficiency tracer technique has been applied using {sup 60} Co as tracer. The beta detection efficiency was changed by external absorbers and extrapolated to unity by linear least square fitting applying covariance methodology. (author)
2001-07-01
Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions
Energy Technology Data Exchange (ETDEWEB)
It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)
2000-07-01
Multi-frequency binary sequence testing at FFTF [Fast Flux Test Facility
International Nuclear Information System (INIS)
The multi-frequency binary sequence experimental technique has been implemented at the Fast Flux Test Facility for routine surveillance activities. The frequency content of the standard rod-movement sequence has been shown to be sufficient to normalize the data at moderate frequencies. This obviates the need for auxiliary calibration measurements and provides the reactivity worth of the test control rod. Analyses of a series of tests conducted in 1986 illustrate that the rod worths inferred from the tests are consistent with zero-power measurements. Also, the dependence of the prompt feedback time constant on reactor conditions was determined.
1988-09-18
Modification of NPL-CRC secondary standards radionuclide calibrator holder to suit for IPEN vials
International Nuclear Information System (INIS)
The procedure followed by the Laboratorio de Metrologia Nuclear (LMN) at the IPEN - CNEN/SP, in Sao Paulo, for modifying the NPL-CRC radionuclide sample holder in order to adapt for IPEN vials is presented. For the quality assurance of the results using the IPEN vials, the influence of variation in dimensions and volume of solution has been investigated and suitable correction factors were applied. The solutions used in the present work were "5"1Cr "9"9"mTc "1"5"3Sm, and "2"0"1Tl. (author)
2000-10-05
In situ observation of axial irradiation growth in liquid-metal reactor metal fuel
International Nuclear Information System (INIS)
Effects of the rapid early-in-life expansion of metal fuel were measured in an irradiation experiment in the Fast Flux Test Facility (FFTF). This important performance/design information was obtainable through the unique combination of a dimensionally stable FFTF oxide core and the calibrated proximity instrumentation associated with the test. These results delineate the time dependence of metal-fuel swelling and provide quantitative estimates of the magnitude of axial fuel swelling in full-length metal-fuel assemblies. Final posttest examination results will define actual fuel column growth levels.
1989-11-26
High Exposure Facility Technical Description
Energy Technology Data Exchange (ETDEWEB)
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
2008-02-12
FADC signal reconstruction for the MAGIC telescope
Energy Technology Data Exchange (ETDEWEB)
Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.
2008-09-11
Experimental Uncertainty for the Thermal Expansion of a Simulated Fuel
Energy Technology Data Exchange (ETDEWEB)
Thermal expansions of a simulated fuel (SS-1) were measured by using a Dilatometer (DIL402C) from room temperature to 1900 K. The main procedure of an uncertainty evaluation followed the strategy of the UO{sub 2} fuel. Referring to the ISO (International Organization for Standardization) guide, the uncertainties of the thermal expansion were quantified in three parts - the initial length, the length variation, and the system calibration factor. The uncertainty of the thermal expansion for a simulated fuel was also compared with those of UO{sub 2} fuel.
2006-07-01
Electron capture decay of sup 203 Pb
Energy Technology Data Exchange (ETDEWEB)
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
1989-01-01
ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD
Energy Technology Data Exchange (ETDEWEB)
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
1983-01-01
Determining nuclear morphology using an improved angle-resolved low coherence interferometry system
We outline the process for determining the morphology of subsurface epithelial cell nuclei using depth-resolved light scattering measurements. The measurements are accomplished using a second generation angle-resolved low coherence interferometry system. The new system greatly improves data acquisition and analysis times compared to the initial prototype system. The calibration of the new system is demonstrated in scattering studies to determine the size distribution of polystyrene microspheres in a turbid sample. The process for determining the size of cell nuclei is discussed by analyzing measurements of basal cells in a sub-surface layer of intact, unstained epithelial tissue.
2003-12-01
Dependence of thermal plasma jet temperature on discharge power and gas flow rate
International Nuclear Information System (INIS)
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
2008-03-01
Beam position monitor readout and control in the SLC linac
Energy Technology Data Exchange (ETDEWEB)
A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.
1985-04-01
Absolute calibration of the antiproton detection efficiency for BESS below 1 GeV
Energy Technology Data Exchange (ETDEWEB)
An accelerator beam experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of the BESS detector. Measured and calculated efficiencies derived from the BESS Monte Carlo simulation based on GRANT/GHEISHA showed good agreement. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux. (author)
2001-12-01
A theoretical study of radon measurement with activated charcoal
Energy Technology Data Exchange (ETDEWEB)
Diffusion of radon in a bed of activated charcoal is described by diffusion equations. An analytical solution of these equations is presented for the case of constant radon concentration in the atmosphere. The solutions are given separately for short term and long term exposure. An analytical form of the calibration constant f for long term exposure and constant radon concentration in air, was found. A numerical method and computer code based on the method of finite elements is developed for the case of variable radon concentration in air. This program simulates radon adsorption by the activated charcoal bed, enabling determination of sensitivity. The dependence of sensitivity on different parameters, such as temperature, thickness of the charcoal, etc. was studied using this program. (orig.) 10 refs.
1998-04-11
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...
1988-08-01
Grid-Search Location Methods for Ground-Truth Collection From Local and Regional Seismic Networks
Energy Technology Data Exchange (ETDEWEB)
This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general ...
2005-05-13
A study of neutron room scattering at RPCF
International Nuclear Information System (INIS)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...
1997-01-05
A study of neutron room scattering at RPCF
Energy Technology Data Exchange (ETDEWEB)
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers dosimeters use CR39 for neutron detection, ...
1996-09-01
International Nuclear Information System (INIS)
Fission track analysis (FTA) technique for the determination of "2"3"9Pu excreted through urine has been standardized using blank samples, tracer and "2"3"9Pu spikes. Double stage anion exchange separation protocol has been applied and an average radiochemical recovery of "2"3"9Pu of 18% was obtained. An average track registration efficiency of 11 tracks per #mu#Bq of "2"3"9Pu, irradiated to 0.35x10"1"7 neutron fluence was established. Reagent blank urine samples from 11 controlled subjects were analyzed by FTA and an average of 149#+-#14 tracks was obtained. Minimum detectable activity of 34 #mu#Bq L"-"1 of urine sample was obtained and will be useful for monitoring chronic exposure cases handling MOX fuel.
2011-07-01
The SysMES framework: System management for networked embedded systems and clusters
Energy Technology Data Exchange (ETDEWEB)
The ALICE heavy-ion particle physics experiment is currently being built at CERN near Geneva. It will use a PC cluster of 900 dual-processor machines for the last stages of the data readout process and a network of 400 microcomputers for the configuration and control of the cluster nodes. One of the most important objectives to be achieved in such experiments is to guarantee the utilized devices are running correctly during the experiment life-time. A second aspect is the extremely high availability and reliability requirements of the applications being run, the so called high level trigger (HLT). The SysMES framework is a scalable, decentralized, fault tolerant, dynamic, rule based tool set for the monitoring of networks of target systems and applications. The management algorithms consist of the following steps: system and application monitoring, recognition of undesirable states, event (message) generation, local event handling on the target, event forwarding to ...
2008-07-01
Material related to routine as well as sensitive aspects of parent/day care center relationships is presented in this training module, one of a series providing staff development information for programs operated for dependents of military personnel. The module offers a brief discussion of ways caregivers can help parents feel at ease about leaving their children in child care and presents a set of multiple-choice skill-building exercises for effectively working with parents. Exercises focus on various topics, including how parents can be approached when their child may have a health problem, when child abuse or neglect is suspected, and when parental cooperation is needed to stop a child's undesirable or disruptive behavior. Exercises are also devoted to the questions of whether or not caregivers should act as advisors to parents or tell parents about their child's behavior at the center. Concluding exercises indicate how caregivers can handle parent requests for ...
1982-04-01
Storage of hazardous substances in bonded warehouses
International Nuclear Information System (INIS)
A variety of special regulations exist in Costa Rica for registration and transport of hazardous substances; these set the requirements for entry into the country and the security of transport units. However, the regulations mentioned no specific rules for storing hazardous substances. Tax deposits have been the initial place where are stored the substances that enter the country.The creation of basic rules that would be regulating the storage of hazardous substances has taken place through the analysis of regulations and national and international laws governing hazardous substances. The regulatory domain that currently exists will be established with a field research in fiscal deposits in the metropolitan area. The storage and security measures that have been used by the personnel handling the substances will be identified to be putting the reality with that the hazardous substances have been handled in tax deposits. A rule base for the ...
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy is currently constructing the Waste Isolation Pilot near Carlsbad, New Mexico. The full-scale pilot plant will demonstrate the feasibility of the safe disposal of defense-related nuclear waste in a bedded salt formation at a depth of 2160 feet below the surface. WIPP will provide for the permanent storage of 25,000 cu ft of remote-handled (RH) transuranic waste and 6,000,000 cu ft of contact-handled (CH) transuranic waste. This paper covers the major mechanical/structural design considerations for the waste hoist and its hoist tower structure. The design of the hoist system and safety features incorporates state-of-the-art technology developed in the hoist and mining industry to ensure safe operation for transporting nuclear waste underground. Also included are design specifications for VOC-10 monitoring system.
1991-12-31
Reliability assessment of embedded digital system using multi-state function
Energy Technology Data Exchange (ETDEWEB)
This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed model is a generalized combinatorial model, the simplification of this model becomes ...
2006-03-15
Energy Technology Data Exchange (ETDEWEB)
The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against and damaged the tank ceiling in the tank, ...
1995-01-01
Under the auspices of the DOE and private industry, considerable progress has been made in: preparation of coal-water fuels; combustion of low-ash coal-based fuel forms; processes to provide deeply-cleaned coal. Developments in advanced beneficiation of coal to meet stringent requirements for low ash and low sulfur can be anticipated to further complicate the problem areas associated with this product. This is attributable to the beneficiated coal being procured in very fine particles with high surface areas, modified surface characteristics, reduced particle size distribution range, and high inherent moisture. Experience in the storage, handling, and transport of highly beneficiated coal has been limited. This is understandable, as quantities of such product are only now becoming available in meaningful quantities. During this reporting period the authors have: developed a suite of empirical tests covering water retention, rewetting, mull stability, angle of ...
1993-01-01
Measuring head for radionuclide X-ray fluorescence analyzer
International Nuclear Information System (INIS)
The design of a gaging head for a portable radionuclide X-ray fluorescence analyzer is described. The gaging head is designed as a construction unit system which enables the application of lateral reflexion geometry as well as of coaxial geometry. It is designed so that adjustment from one geometry to the other is labour and time saving. The selection of characteristic radiation is performed by a couple of Ross' differential filters. These filters are prepared by a novel technique developed by our laboratory. The filter exchange is effected by the longitudinal move of the couple of filters encapsulated in a holder. The shift of the filters is controlled by means of a triggering mechanism situated in the body of the gaging head handle. This design makes is possible to handle the gaging head during measurements with one hand. A simple interchange of the absorption filter for the transmissive filter allows the operator to avoid any unwanted shift ...
1976-05-21
LHC Magnet Tests Operational Techniques and Empowerment for Successful Completion
The LHC magnet tests operation team developed various innovative techniques, particularly since early 2004, to complete the superconductor magnet tests by Feb. 2007. Overall and cryogenic priority handling, rapid on-bench thermal cycling, rule-based goodness evaluation on round-the-clock basis, multiple, mashed web systems are some of these techniques applied with rigour for successful tests completion in time. This paper highlights these operation empowerment tools which had a pivotal role for success. A priority handling method was put in place to enable maximum throughput from twelve test benches, having many different constraints. For the cryogenics infrastructure, it implied judicious allocation of limited resources to the benches. Rapid On-Bench Thermal Cycle was a key strategy to accelerate magnets tests throughput, saving time and simplifying logistics. First level magnet appraisal was developed for 24 hr decision making so as to ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
The study presented in this thesis is a contribution toward improving the reliability of Metallized Polypropylene Film (MPPF) capacitors achieved by a better design. A temperature distribution in the roll is assumed with the aim of optimizing its thermal performance. It appears that the heating of long capacitor is higher than that of equivalent flat capacitor subjected to the same electric stresses. Standard accelerated aging tests (temperature and voltage) of MPPF capacitors have been performed with the aim to evaluate the dielectric performance and thus the capacitor lifetime. The statistical approach showed that the failure mode may be represented by two parameter Weibull distribution and the experimental approach proved that long capacitor deteriorates faster than a plate-shaped having the same features. Although capacitors with long geometry seem to have a poor pulse handling performance, we found that the quality of the, end-edge contact is strongly ...
2001-12-01
Energy Technology Data Exchange (ETDEWEB)
The criterion the study is based on in evaluating environmental risks is the possibility of harmful changes in air, water and soils rather than the harmful environmental impacts these changes are caused by. The two significant criteria, i.e. the evaluated environmental hazards potentials or 'value parameters', and the evaluated damage-to-the-environment probabilities or 'safety parameters', reveal the respective environmental risks or 'risk factors'. These risk factors are classified by 23 environmental risk parameters for differentiation between low-risk and high-aid for pollution abatement measures provided that one fixes acceptance limits for the environmental parameters. As a rule the environmental risks of technical facilities which handle hazardous materials can be evaluated appropriately and the results can be compared. (orig./HSCH).
1992-02-07
Donetskgormash association in the 11th five-year plan, tasks for the 12th five-year plan
Energy Technology Data Exchange (ETDEWEB)
This paper evaluates activities from 1981 to 1985 of the Donetskgormash association which develops and manufactures equipment for coal mining. The association has manufactured 1,410 hoists, 274 blowers and 26 bucket wheel excavators. Sixteen experimental units of new mining equipment have been developed, among others the RPM 3600-42.5/90 bucket wheel excavator (with a capacity of 3,600 m/sup 3//h for coal handling in storage yards of large power plants), the bucket wheel system used in the EhR 630-10.5/0.5 excavator and the PZ 1600-17/20 materials handling system. Among 20 equipment types manufactured from 1981 to 1985, 4 types were manufactured in the USSR for the first time (e.g. the MPP shaft sinking system and the VOD-50 mine blower). Use of new types of equipment manufactured by the association economized about 46 million rubles in coal mines. From 1986 to 1990 production of mining equipment in the association should increase by 133%; ...
1986-03-01
Design study of pyrochemical process operation by using virtual engineering models
International Nuclear Information System (INIS)
This report describes accomplishment of simulations of Pyrochemical Process Operation by using virtual engineering models. The pyrochemical process using molten salt electrorefining would introduce new technologies for new fuels of particle oxide, particle nitride and metallic fuels. This system is a batch treatment system of reprocessing and re-fabrication, which transports products of solid form from a process to next process. As a results, this system needs automated transport system for process operations by robotics. In this study, a simulation code system has been prepared, which provides virtual engineering environment to evaluate the pyrochemical process operation of a batch treatment system using handling robots. And the simulation study has been conducted to evaluate the required system functions, which are the function of handling robots, the interactions between robot and process equipment, and the time schedule of process, in the ...
Coal quality engineering analysis aids plant performance
Energy Technology Data Exchange (ETDEWEB)
The Coal Quality Engineering Analysis (CQEA) program developed by the New York State Electric and Gas Company (NYSEC) calculates the as-burned cost of burning a specific coal in a specific generation unit. These costs include: maintenance costs for coal and ash handling equipment; ash disposal costs; cost of oil (if required for flame stability and/or derating because of pulverizer capacity limitation); flue gas desulfurization costs; cost of replacement power caused by pulverizer, precipitator fly ash collection and bottom ash capacity limitation; boiler losses due to moisture, hydrogen, dry gas and unburned carbon; power for coal and ash handling equipment; power for coal pulverizers; cost of using excess air to prevent slagging of coal with low ash softening temperatures; and effect of heat rate on coal tonnage required for a desired generation. The use of CQEA to identify areas in which plant operations may be improved is discussed. 7 ...
1988-10-01
BNFL Report Glass Formers Characterization
Energy Technology Data Exchange (ETDEWEB)
The objective of this task was to obtain powder property data on candidate glass former materials, sufficient to guide conceptual design and estimate the cost of glass former handling facilities as requested under Part B1 of BNFL Technical and Development Support. Twenty-nine glass forming materials were selected and obtained from vendors for the characterization of their physical properties, durability in caustic solution, and powder flow characteristics. A glass former was selected based on the characterization for each of the ten oxide classes required for Envelope A, B, and C mixtures. Three blends (A, B, and C) were prepared based on formulations provided by Vitreous State Laboratory and evaluated with the same methods employed for the glass formers. The properties obtained are presented in a series of attached Tables. It was determined that five of the ten glass formers, (kyanite, iron oxide, titania, zircon, and zinc oxide) have the potential to cause some ...
2000-07-27
Automation in a material processing/storage facility
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site (SRS) is currently developing a new facility, the Actinide Packaging and Storage Facility (APSF), to process and store legacy materials from the United States nuclear stockpile. A variety of materials, with a variety of properties, packaging and handling/storage requirements, will be processed and stored at the facility. Since these materials are hazardous and radioactive, automation will be used to minimize worker exposure. Other benefits derived from automation of the facility include increased throughput capacity and enhanced security. The diversity of materials and packaging geometries to be handled poses challenges to the automation of facility processes. In addition, the nature of the materials to be processed underscores the need for safety, reliability and serviceability. The application of automation in this facility must, therefore, be accomplished in a rational and disciplined manner to satisfy the strict ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based on Raman and ...
1995-09-01
A study on the fuel handling control system in CANDU 6 nuclear power plants
Energy Technology Data Exchange (ETDEWEB)
The Fuel Handling(F/H) System in existing CANDU 6 nuclear power plants was designed in the early 1960`s, utilizing the technology available at that time. The design for the F/H control system has been proven to be excellent in meeting the functional requirements through more than 20 CANDU units in service or under construction. The significant advance in electrical and electronic engineering area in a few decades motivates the design changes to reduce costs for engineering, construction and operation as well as to improve performance, reliability and safety based on the latest technology. This report outlines the current design of the F/H system, especially for the F/H control system, introduces some topics in research and development projects being carried out by AECL or other institutes, and presents several potential design improvement items for the better CANDU system with brief explanation about implementation. 29 figs., 2 tabs., 27 refs. (Author).
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
Concerning high performance composite solid propellant BAMO and BAMO-based copolymers, synthetic method and properties of them were studied. Comparison graph of theoretical specific impulse for various propellants were shown, by that, reason why highest specific impulse BAMO was selected as direction of the study. As the orientation of synthesis, those were indicated that radicals at both ends should be hydroxyl so as urethane bonding was available, that liquid at normal temperature was required for easy handling, and that glass transition temperature is required to be low enough. Synthesis was conducted by ring-opening polymerization of ring ether detail procedures of which were explained. Measurements of properties was performed for thermochemical properties, thermal decomposition, combution heat, and friction sensitivity test to confirm safety. As the result, those were understood that thermal decomposition was divided into two phases, rapid exothermal ...
1990-08-31
Waste Management Project fiscal year 1998 multi-year work plan, WBS 1.2
Energy Technology Data Exchange (ETDEWEB)
The Waste Management Project manages and integrates (non-TWRS) waste management activities at the site. Activities include management of Hanford wastes as well as waste transferred to Hanford from other DOE, Department of Defense, or other facilities. This work includes handling, treatment, storage, and disposal of radioactive, nonradioactive, hazardous, and mixed solid and liquid wastes. Major Waste Management Projects are the Solid Waste Project, Liquid Effluents Project, and Analytical Services. Existing facilities (e.g., grout vaults and canyons) shall be evaluated for reuse for these purposes to the maximum extent possible.
1997-09-23
Vibration experiment for a three-loop PWR reactor building
Energy Technology Data Exchange (ETDEWEB)
Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparisons, the adequacy of the analytical method employed for the design was confirmed.
1983-12-01
Energy Technology Data Exchange (ETDEWEB)
This study investigates spent fuel cask handling experience at existing nuclear facilities to determine appropriate cask decontamination and maintenance operations at the potential Yucca Mountain repository. These operations are categorized as either routine or nonroutine. Routine cask decontamination and maintenance tasks are performed in the cask preparation area at the repository. Casks are taken offline to a separate cask maintenance area for major nonroutine tasks. The study develops conceptual designs of the cask preparation area and cask maintenance area. The functions, layouts, and major features of these areas are also described.
1992-04-01
The role of brachytherapy in radiation and isotopes centre of Khartoum (RICK)
International Nuclear Information System (INIS)
As there are many efforts devoted in order to manage the cancer, here the researcher handle one of these efforts that play a major part in treating the cancer internationally, it is a brachytherapy system. Brachytherapy was carried out mostly with radium sources, but recently some artificial sources are incorporated in this mode of treatment such as Cs-137, Ir-192, Au-198, P-32, Sr-90 and I-125. The research cover history of brachytherapy and radioactive sources used in, techniques of implementation, radiation protection and methods of brachytherapy dose calculation, as well as brachytherapy in radiation and isotopes centre in Khartoum.
Surfactant flooding - an overview of recent French results
Energy Technology Data Exchange (ETDEWEB)
Enhanced recovery by chemical flooding using surfactant and/or polymers simultaneously implies the following: (1) a fundamental knowledge of the physical chemistry of micellar systems and interfaces; (2) the proper formulation of mathematic models handling the basic mechanisms of oil recovery; and (3) the use of field-scale pilot units to test the validity of the models and to acquire technical knowledge. Efforts have been made by the French in these directions, and the main results are described. Special attention is paid to the search for new products and the improvement of manufacturing processes. 10 references.
1983-01-01
Savannah River Site Interim Waste Management Program Plan FY 1991--1992
Energy Technology Data Exchange (ETDEWEB)
The primary purpose of the Waste Management Program Plan is to provide an annual report of how Waste Management's operations are conducted, what facilities are being used to manage wastes, what forces are acting to change current waste management systems, and what plans are in store for the coming fiscal year. In addition, this document projects activities for several years beyond the coming fiscal year in order to adequately plan for safe handling, storage, and disposal of radioactive wastes generated at the Savannah River Site and for developing technology for improved management of wastes. In this document, work descriptions and milestone schedules are current as of December 1991.
1992-05-01
Repair shops and back-up facilities of the Belchatow mine
Energy Technology Data Exchange (ETDEWEB)
Repair and maintenance for equipment used in the Belchatow brown coal mine and organizational models of repair services in the mine are discussed. Maintenance of earthmoving equipment, spreaders, bucket wheel excavators, loaders and other coal handling equipment, belt conveyors and drive systems for belt conveyors is discussed. Repair shops in the mine also manufacture about 35% of spare parts and elements for equipment used in the mine. Reliability of mining equipment, repairs and repair capacity of the shops are discussed. Organizational models of repair services, equipment used by these services and repair personnel are described. Effects of repair services on operation of the mine are evaluated.
1984-01-01
International Nuclear Information System (INIS)
The symposium covers papers under different sections namely, (i) Core physics and Fuel management, (ii) Commissioning of facilities and systems, (iii) Operational experience and Human resource development, (iv) Fuel handling, Maintenance management and Surveillance, (v) Instrumentation and Control and Power supply systems, (vi) Analysis, modifications and developments for enhancing operational safety, (vii) Chemistry control and Effluent management, (viii) Radiation and industrial safety and (ix) Steam generators, Turbo-generators and other auxiliaries. Papers relevant to INIS are indexed separately. (author)
2006-11-13
Phenomenological model for the Drell-Yan process: Reexamined
International Nuclear Information System (INIS)
Drell-Yan pair production is investigated. We reexamine a model where the quark momentum fraction is defined as the ratio of the corresponding light-cone components of the quark and parent nucleon in a naive parton-model approach. It is shown that the results differ from the standard parton model. This is due to unphysical solutions for the momentum fractions within the naive approach which are not present in the standard parton model. In a calculation employing full quark kinematics, i.e., including primordial quark transverse momentum, these solutions also appear. A prescription is given to handle these solutions in order to avoid incorrect results. The impact of these solutions in the full kinematical approach is demonstrated and compared to the modified result.
2010-02-01
PFP dangerous waste training plan
This document establishes the minimum training requirements for the Plutonium Finishing Plant (PFP) personnel who are responsible for management of dangerous waste. The training plan outlines training requirements for handling of solid dangerous waste during generator accumulation and liquid dangerous waste during treatment and storage operations. The implementation of this training plan will ensure the PFP facility compliance with the training plan requirements of Dangerous Waste Regulation. Chapter 173-303-330. Washington Administrative Code (WAC). The requirements for such compliance is described in Section 11.0 of WHC-CM-7-5 Environmental Compliance Manual.
1996-01-01
International Nuclear Information System (INIS)
The purpose of the Ocean FUSRAP Program, which began in March 1981, is to assess the technical, environmental, and institutional feasibility of disposing, in the ocean and on the ocean floor, of FUSRAP waste which contains traces of natural radioactive materials. The initial planning has focused on the Middlesex, New Jersey, Sampling Plant site and surrounding properties, which contain on the order of 100,000 metric tons of material. The Belgian Congo uranium ore and other uranium ores used by the United States were handled at the sampling plant site and have since been removed.
NEUTRON-ABSORBING BRICKS MADE FROM CaB$sup 6$
nsive neutron-absorbing bricks from commercially available CaB/sub 6/ powder. The bricks are 2 x 3 x 5 in., and are strong enough to withstand normal handling. They last indefinitely; the ones described are now 7 years old, used and stored under normal room temperatures and humidities. The procedure is to make a thick, dry mud with the powder and water, followed by compression in a mold at pressures of about 1 ton/in./sup 2/ or more. The bricks are then baked for 2 hours or longer at a temperature of about 750 deg C. (auth)
1960-05-01
International Nuclear Information System (INIS)
This study illustrates the way to perform protocols, collect samples, and conduct laboratory analyses in order to characterize the physical properties of wood used in the industrial sector of the Valle de Aburra metropalitan area and the gains obtained by characterizing the properties of the most frequently used woods. In this investigation some of the most important sampling parameters are presented, such as taking samples in piles or accumulations of waste, handling of these samples in the laboratory and others of great importance such as the ignition point. the proposed methodology is based upon some of the international astm coal norms, for the similarity it has with wood and for the lack of information on sampling this type in wood
Energy Technology Data Exchange (ETDEWEB)
In order to improve the handling capability of red mud, it is mixed with fine-grain coal material such as brown coal or lignite in dust form, in a ratio by weight of between 0.5-10:1. The liquid present in the red mud is bound by the very fine coal admixed therewith so that the resulting mixture can be stored in a silo and even pneumatically conveyed, and the oily properties of the red mud are removed by the treatment. The mixture is particularly suitable for use in connection with the hydrogenating liquefaction of coal in which the red mud is used as a catalyst.
1984-08-07
Laboratory robotics systems at the Savannah River Laboratory
International Nuclear Information System (INIS)
Many analytical chemistry methods normally used at the Savannah River site require repetitive procedures and handling of radioactive and other hazardous solutions. Robotics is being investigated as a method of reducing personnel fatigue and radiation exposure and also increasing product quality. Several applications of various commercially available robot systems are discussed involving cold (nonradioactive) and hot (radioactive) sample preparations and glovebox waste removal. Problems encountered in robot programming, parts fixturing, design of special robot hands and other support equipment, glovebox operation, and operator-system interaction are discussed. A typical robot system cost analysis for one application is given.
1983-11-16
Energy Technology Data Exchange (ETDEWEB)
A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)
2007-11-15
Hazardous waste operational plan for site 300
Energy Technology Data Exchange (ETDEWEB)
This plan outlines the procedures and operations used at LLNL's Site 300 for the management of the hazardous waste generated. This waste consists primarily of depleted uranium (a by-product of U-235 enrichment), beryllium, small quantities of analytical chemicals, industrial type waste such as solvents, cleaning acids, photographic chemicals, etc., and explosives. This plan details the operations generating this waste, the proper handling of this material and the procedures used to treat or dispose of the hazardous waste. A considerable amount of information found in this plan was extracted from the Site 300 Safety and Operational Manual written by Site 300 Facility personnel and the Hazards Control Department.
1982-02-12
Energy Technology Data Exchange (ETDEWEB)
This paper describes the safety system and training for personnel on board the floating production storage and offloading (FPSO II) currently working in the Cadlao Field, offshore Palawan in the Philippine Islands. (See Figure 1). The crude oil being produced has wellstream hydrogen sulfide concentrations up to 6000 PPM. Concentrations of hydrogen sulfide at 700 PPM or higher can be immediately dangerous to life and every effort must be made to ensure personnel safety.
1984-02-01
International Nuclear Information System (INIS)
The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)
Energy Technology Data Exchange (ETDEWEB)
This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.
1987-01-01
Evolution of reactivity control mechanisms for nuclear research and power reactors in India
International Nuclear Information System (INIS)
Division of Remote Handling and Robotics (DRHR) at Bhabha Atomic Research Centre (BARC) has been working on design and development of Reactivity Control Mechanisms for Nuclear Research Reactors (Dhruva, KAMINI and recently Critical Facility of Advanced Heavy Water Reactor (AHWR)) as well as Power Reactors in India (Pressurized Heavy Water Reactors of 220 MWe at Narora and recently India's first 540 MWe PHWR Unit -1 and 2 at Tarapur). This paper gives a brief account of evolution of reactivity control mechanisms for nuclear research and power reactors in India. (author)
2009-10-01
Evaluation of wastewater treatment requirements for thermochemical biomass liquefaction
Biomass can provide a substantial energy source. Liquids are preferred for use as transportation fuels because of their high energy density and handling ease and safety. Liquid fuel production from biomass can be accomplished by any of several different processes including hydrolysis and fermentation of the carbohydrates to alcohol fuels, thermal gasification and synthesis of alcohol or hydrocarbon fuels, direct extraction of biologically produced hydrocarbons such as seed oils or algae lipids, or direct thermochemical conversion of the biomass to liquids and catalytic upgrading to hydrocarbon fuels. This report discusses direct thermochemical conversion to achieve biomass liquefaction and the requirements for wastewater treatment inherent in such processing. 21 refs.
1992-04-01
Estimating the tritiated hydrocarbon decontamination factor by heavy methane
International Nuclear Information System (INIS)
As part of the start up of Los Alamos National Laboratory's new tritium-handling facility, the efficiency of a catalytic oxidation tritium decontamination system was investigated using deuterated methane. The tests were performed during the start up of the facility to confirm the operability of the system before introducing tritium and to provide a baseline for comparison. Techniques and instruments normally used for atmospheric tracer experiments using deuterated methane were applied virtually without modification. The sensitivity of this method allowed preliminary checks at the sub-ppm (v/v) level.
Electronic system hardening methodology
International Nuclear Information System (INIS)
The notion of hardened systems can be found in several applications (nuclear power plants, alarm systems, research installations..). Their development correspond to the functional necessity to take into account a specific radiative environment. The starting point of each hardening study is the definition of the radiative environmental constraints representative of the application. In addition to these external constraints, the specific functional characteristics of each system are considered: control or interface systems in nuclear industry, in-board control systems, remote handling systems, etc. This paper summarizes the methodology followed according to the experience gained in previous studies and anticipating the future needs. (J.S.). 6 refs., 5 figs.
Development of the alcohol waste processing equipment
International Nuclear Information System (INIS)
In the experimental fast Reactor JOYO, gripper of Fuel Handling Machine and Ex-Vessel Transfer Machine that the sodium adhered is being washed with alcohol. This radioactive alcohol waste that was used to the washing is stored to the tank. If it is able to separate the alcohol and sodium in the alcohol waste it becomes possible to dispose of the alcohol waste. Japan Nuclear Institute and Fuji Electric Systems CO., LTD. Developed the device that adds carbonic acid gas to the alcohol waste and cause the sodium in the alcohol waste separated as carbonate and remove this carbonate by using the thin film evaporator. (author)
2004-11-01
International Nuclear Information System (INIS)
Remote-controlled handling systems are required for work to be done in the decommissioning and dismantling of nuclear facilities. These systems are equipped with electronic devices suitable for use in working environments affected by ionizing radiation. The publication explains the step-wise progress achieved for improving the radiation resistance of electronic devices with the example of a four-quadrant controlling device for the motors of a manipulator. The radiation resistance of the device could be enhanced to radiation energies of 5.500 Gy. This means that a manipulator vehicle equipped with this controlling device can take up to approx. 15 kGy all in all, taking into account its own shielding properties. (DG).
Computer modelling for risk assessment of transportation using methods of fuzzy set theory
International Nuclear Information System (INIS)
Computer software for risks assessment of transportation of important freight has been developed. It incorporates models of transport accidents, including terrorist attacks. These models use, among the others, unput data of cartographic character. Geographical information system technology and electronic maps of an area are involved as an instrument for handling this kind of data. Fuzzy set theory methods as well as standard methods of probability theory have been used for quantitative risk assessment. Fuzzy algebraic operations and their computer realisation are discussed. One preliminary example of risk assessment is described. (authors)
1998-05-10
The goal of this research program has been to add to our understanding of the breakup of molten fuel jets penetrating reactor coolant. Easily handled working fluids are used to simulate fuel jet breakup, so that detailed observations may be obtained from a relatively large number of experiments. The tools used for observing this behavior are high speed notion picture photography, Flash X-radiography, and X-ray cine. Jet breakup lengths are determined from motion pictures; the mechanisms by which the jets are fragmented may be inferred from radiographs.
1992-01-01
Bringing robotics technology down to Earth
International Nuclear Information System (INIS)
Robotics technology is successfully being transitioned from space to terrestrial applications. It is being modified and enhanced to help in the US DOE's Environmental Restoration and Waste Management Program. Some examples of these applications, ranging from large multijointed manipulators to autonomously navigated remote vehicles, are outlined in this article. They include the following: underground storage tank technology demonstration; light-duty utility arm system; remotely controlled material-handling system; remotely operated excavator; self-guided transfer vehicle. 10 figs.
Artificial intelligence: the future in nuclear plant maintenance
Energy Technology Data Exchange (ETDEWEB)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-12-01
Artificial intelligence: the future in nuclear plant maintenance
International Nuclear Information System (INIS)
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
1984-09-23
Analysis of tritium mission FMEF/FAA fuel handling accidents
Energy Technology Data Exchange (ETDEWEB)
The Fuels Material Examination Facility/Fuel Assembly Area is proposed to be used for fabrication of mixed oxide fuel to support the Fast Flux Test Facility (FFTF) tritium/medical isotope mission. The plutonium isotope mix for the new mission is different than that analyzed in the FMEF safety analysis report. A reanalysis was performed of three representative accidents for the revised plutonium mix to determine the impact on the safety analysis. Current versions computer codes and meterology data files were used for the analysis. The revised accidents were a criticality, an explosion in a glovebox, and a tornado. The analysis concluded that risk guidelines were met with the revised plutonium mix.
1997-11-18
Energy Technology Data Exchange (ETDEWEB)
The first biogas plant using the Plauen method has been operated without failures in the Saxon Vogtland since May 1987. This large scale anaerob treatment plant which is the first one in Germany handles besides agricultural recidual substance both municipal and industrial organic residues. The results show clearly that fermentation is a real alternative to composting, combusting and deponing. (orig.)
1994-01-01
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
A fast production scheduler for generation expansion planning in a hydro-thermal system
Energy Technology Data Exchange (ETDEWEB)
A fast production scheduling algorithm suitable for generation expansion studies is described in this paper. It can handle several independent rivers, thermal plants, pumped storage plants, import, export, and internal non-firm markets. Inflows and load are deterministic and a one-reservoir limit is imposed on each river. The scheduling problem is formulated as a generalized network problem which is efficiently solved by an adaption of the simplex method. The algorithm is part of a program developed by Hydro-Quebec to conduct preliminary evaluations of alternative expansion plans. The program and the scheduling algorithm are presented.
1986-01-01
A fast production scheduler for generation expansion planning in a hydro-thermal system
Energy Technology Data Exchange (ETDEWEB)
A fast production scheduling algorithm suitable for generation expansion studies is described in this paper. It can handle several independent rivers, thermal plants, pumped storage plants, import, export, and internal non-firm markets. Inflows and load are deterministic and a one-reservoir limit is imposed on each river. The scheduling problem is formulated as a generalized network problem which is efficiently solved by an adaption of the simplex method. The algorithm is part of a program developed by Hydro-Quebec to conduct preliminary evaluations of alternative expansion plans. The program and the scheduling algorithm are presented.
1987-02-01
Waste Handling Shaft concrete liner degradation conclusions and recommendations
International Nuclear Information System (INIS)
The primary function of the Waste Handling Shaft (WHS) at the Waste Isolation Pilot Plant (WIPP) is to permit the transfer of radioactive waste from the surface waste handling building to the underground storage area. It also serves as an intake shaft for small volumes of air during normal storage operations and as an emergency escape route. Part of the construction was the placement of a concrete liner and steel reinforced key in 1984. During a routine shaft inspection in May 1990, some degradation of the WHS concrete liner was observed between the depths of 800 and 900 feet below the ground surface. Detailed investigations of the liner had been carried out by Sandia National Laboratories and by Westinghouse Electric Corporation Waste Isolation Division (WID) through Lankard Materials Laboratory. Observations, reports, and data support the conclusion that the concrete degradation, resulting from attack by chemically aggressive brine, is a ...
Results and recommendations from studies of basic handling characteristics of solid biomass fuels
Energy Technology Data Exchange (ETDEWEB)
Main results are summarised for a project carried out with the aim of increasing the knowledge of relations between handling characeristics and properties such as moisture content, particle size and shape etc. Handling characteristics that were studied: angle of repose, friction between fuel and different surfaces, the fuel`s tendency to bridge across openings, and its freezing characteristics. Some forty solid biomass fuels were studied, mainly wood fuels, with particle sized from 1 to 200 mm. New methods were developed for measurement of bridging across openings and freezing characeristics. The angle of repose varied between 25 and 55 deg. The particle shape had a significant influence, a high ratio of length/thickness gave a high angle of repose. When the fuel moisture content was increased the angle of repose first increased, then decreased, and finally increased again. The particle size had no influence. The friction depended more on the ...
1996-12-31
g factors and lifetimes for 2_1"+ states of sup(84,86,88)Sr
International Nuclear Information System (INIS)
The g factors of the 2_1"+ states in sup(84,86,88)Sr have been deduced using the thin-foil transient field technique with the field calibration of the Rutgers group. The values are g("8"4Sr)= + 0.419(47), g("8"6Sr)= + 0.273(50) and g("8"8Sr)= + 1.15(17). The mean lifetimes of the 2_1"+ states in sup(86,88)Sr were determined by the Doppler-shift attenuation method to be 2.10(22) ps and 0.219(23) ps respectively. The g factor and lifetime results are compared with shell model and interacting boson model predictions. (author).
Transient testing of FFTF fuel pins in TREAT
International Nuclear Information System (INIS)
A series of six transient tests was performed on FFTF irradiated fuel pins to demonstrate their transient performance capability. The tests were performed in the TREAT reactor using sodium loops and instrumented test trains. The TEMECH computer code was used to design overpower transients which would simulate FFTF fuel pin thermal conditions during slow and fast unprotected transients. Some tests were run to substantial overpower levels but terminated prior to fuel pin failure, while other tests were intentionally extended to fuel failure to establish failure thresholds and characteristics. Post-test examination data provided significant cladding strain and fuel melting information used for performance code calibration and validation. These data showed that cladding damage caused by fuel melting is related to the steady state condition of the fuel.
1986-09-07
Thermal radiation from hot surfaces measured by optical and calorimetric methods. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
The radiative heat loss from a surface is determined by its total hemispherical emittance, which consequently plays an important role in aerospace and solar applications. This study compares emittances measured calorimetrically with values derived from near normal incidence spectral reflectance measurements. This optical derivation is based on a number of assumptions which limit the accuracy if not sufficiency fulfilled. These assumptions include sample specularity, a straybody character beyond the range of measurement, only small variations of emittance with temperature, and a perfectly smooth sample surface. The comparison of calorimetrically and optically derived emittance performed in this study not only quantifies the errors introduced by insufficient fulfillment of the assumptions but also identifies which assumption causes the dominant error. The calorimetric emissometer, constructed for this study and based on a heat flow sensor, was calibrated with ...
1982-01-01
The Multipoles Factory An Element of the LHC Control
The measurements performed at CERN on prototypes and first pre-series main dipole magnets confirm the need of an active control of the Large Hadron Collider to compensate the dynamic field changes during the proton beam injection and acceleration. This control requires in turn an accurate forecast of the magnetic field in the accelerator. We plan to predict the field on the basis of two elements: theoretical field models tailored through the accumulated knowledge of the main magnets during series tests, and an on-line measurement system running on few reference magnets tracking the LHC current cycle. Data coming from this "Multipoles Factory" will result from the fusion of the two sources. Based on this system we foresee to deliver calibration information for pre-defined accelerator cycles as well as real time information for the active control. In this paper we report the conceptual design of the system, and we discuss the features and performance of the models ...
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
The objectives of this study were to estimate symbiotic nitrogen fixation by two common pasture legumes, Trifolium subterraneum L. and Medicago truncatula Gaertn., and an Australian native legume, Acacia dealbata Link, growing in pots using an indirect isotopic method. This method was also used to calibrate the C2H2 reduction assay of the intact plants. In addition, hydrogen evolution was measured in an attempt to explain the variations in C2H2:N2 ratios between the species. 25 refs.; 1 figure; 4 tabs.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.
2001-01-01
Energy Technology Data Exchange (ETDEWEB)
Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)
2009-07-01
Space power systems prelaunch integration
International Nuclear Information System (INIS)
The sequence of events from the assembly of a space nuclear power system to its integration in the Space Shuttle Transportation System (STS) is considered. First, the sequence followed for SNAP-10A, the only free world space reactor electric power system ever launched and operated in space, is reviewed. Before shipment, the SNAP-10A reactor was raised to operating temperature using electrically supplied heat and operated at low power for control calibration. Next we discuss shipment to the launch site, a phase that is critical because of the potential for various accidents. Once the power system arrives at the launch site, the processing sequence is performed. This sequence includes checkout, mating with the payload or upper stage launch vehicle, and integration into the STS.
British Library Electronic Table of Contents (United Kingdom)
A distributed watershed hydrologic model soil and water assessment tool (SWAT, 2000 Version) was applied to simulate stream flow and nutrient loadings (including total nitrogen (TN) and total phosphorus (TP)) in Gucheng Lake Basin, which is located in the lower reach of Yangtze River Basin. Model parameters related to stream flow and nutrient loadings were calibrated and validated by the observed value, and the simulation showed that the simulated values were reasonably comparable to the observed data, suggesting the validity of SWAT model. The simulated surface runoff and nutrient yield between two stages, viz. 1981-2000 and 1951-1960, were compared, basically considering land reclamation in the mid-1970s. The result indicated that, the average annual runoff and output of TN and TP in 198...
2009-01-01
Robotic drilling system for titanium structures
British Library Electronic Table of Contents (United Kingdom)
Manual drilling in titanium structures is a tedious and labor-intensive work. To reduce man-hour requirements while concurrently improving hole quality, we developed a robotic drilling system for this application. The lean system contains the product holding fixture, the industrial robot, the end effector, the control and sensor system, and the offline programming. The system functions include locating workpiece with a calibration stick or the vision system, weld mark inspection, one-sided clamping, drilling and reaming hole in material stack combinations of titanium and aluminum, and real-time thrust force feedback. The positional accuracy and the repeatability of the system have successfully been placed within the specification?s 0.3?mm tolerance and 0.2?mm tolerance, respectively. The d...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)
2001-07-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Reliability analysis of the downstream face of a rockfill dam. Introductory work
Energy Technology Data Exchange (ETDEWEB)
Reliability analysis is now being used to a large extent for several civil engineering structures. Such analysis has not been used for rockfill dams, the most common dams in Norway. Following work on reliability analysis for breakwaters, reliability analysis was then used to investigate the ability of the stone material on the upstream face of a rockfill dam to withstand wind generated waves. An attempt is made to follow up this work by including discharge overtopping on a rockfill dam in a reliability analysis. This report primarily goes through previous work on the required weight of protective stones on the downstream face of the dam for specified discharges over the dam and also deals with the probability formulation of extreme floods. A failure function with partial coefficients is formulated. But for reasons of economy the calibration of the partial coefficients remains for a next phase of the project. 14 refs., 17 figs.
1995-02-01
Reactivity from power spectral density measurements with /sup 252/Cf. [LMFBR
The theory of a method of determination of the reactivity from power spectral density measurements with /sup 252/Cf and the results of experiments with a critical assembly mock-up of a liquid-metal fast breeder reactor and with uranium (93.2 wt % /sup 235/U) metal cylinders and a sphere are presented. This method of reactivity determination has an advantage over existing methods in that it determines the reactivity only from properties of the reactor at the subcritical state of interest and thus does not require a calibration near delayed criticality. In these experiments the reactivity was varied by changing the fissile loading or the amount of neutron absorber inserted; for the LMFBR mock-up, the reactivity varied to approximately 75 dollars subcritical, and for the uranium metal assemblies, to approximately 30 dollars subcritical.
1977-08-01
Rapid and precise measurement of flatband voltage
The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held and read on a digital voltmeter.
1976-05-01
Quantitative bone scintigraphy. A methodological evaluation in prostate cancer
Energy Technology Data Exchange (ETDEWEB)
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.
2000-03-01
Quantitative bone scintigraphy. A methodological evaluation in prostate cancer
International Nuclear Information System (INIS)
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
The general objective of this workshop is to investigate and discuss methods by which uncertainties in mass balance models for toxics in the Great Lakes may be reduced. As described by the workshop prospectus, this paper is focused on problems of reducing (and quantifying) uncertainty as they relate to in situ field observations/system response measurements for the establishment of initial conditions, boundary conditions, calibration/confirmation data sets, and model post-audit data sets.'' I have taken this description to refer not only to the evaluation of uncertainty in the field observations themselves, but also to the uncertainty associated the analyses of in situ observations as they interact in the overall modeling process. Thus, I will be concerned here with quantification and reduction of uncertainty both (1) as they may be applied to descriptions of the system that is being modeled and (2) as they may be associated with model ...
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
1999-07-01
Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}
Energy Technology Data Exchange (ETDEWEB)
The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.
2005-06-13
Powertrain and apparatus using a continuously variable ratio transmission to improve fuel economy
Energy Technology Data Exchange (ETDEWEB)
An automotive powertrain includes a conventional piston engine, a continuously variable ratio transmission, an engine speed sensor and a feedback control system. The control system adjusts both the transmission ratio and the throttle valve in the engine carburetor or fuel metering system in response to the position of the accelerator pedal and in response to the crankshaft speed as measured by the engine sensor. The transmission provides extreme overdrive gear ratios which allow the engine to be operated at wide open throttle even during moderate cruising, and, in addition, the engine carburetor or fuel metering system is calibrated to deliver to the engine a stoichiometric air-fuel mixture which is combined, before combustion, with a special proportion of recirculated exhaust gas. As a result of extensive wide open throttle engine operation with the above mentioned intake charge composition, combustion variables are optimized to produce exceptional fuel economy.
1981-07-28
Peel-off case failure in thermal explosions observed by the deflagration cylinder test
British Library Electronic Table of Contents (United Kingdom)
We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...
2009-01-01
Optimizing the emissions and diesel replacement on a dual fuel, two stroke bus engine
Energy Technology Data Exchange (ETDEWEB)
Two natural gas/diesel dual fuel conversion systems for the Detroit Diesel 6V-71 transit bus engine were described. The basic concept of a dual fuel engine was to operate a diesel engine with both liquid fuel injection and a lean premixed gas mixture. The engine achieved high efficiency due to the high compression ratio typical of the diesel engine. Test results were obtained using three different calibrations on one engine. The objectives were to match existing engine performance with improved emissions and better overall fuel economics. Results showed that overall, engine conversion has both economic and emissions advantages over a straight diesel engine. However, the durability and in-use applicability of the system remains to be demonstrated with an in-bus demonstration project.. 3 tabs., 4 figs.
1995-12-31
British Library Electronic Table of Contents (United Kingdom)
The study investigates the possibility of enhancing crop water productivity in the parts of Northwest India where groundwater quality is marginal and canal water supply is severely scarce. Soil, Water, Atmosphere and Plant (SWAP) model was calibrated and validated in three farmers' fields with varying canal water availability and groundwater quality in the Kaithal Irrigation Circle of the Bhakra Canal system, Haryana. On the basis of predicted and observed soil water content, pressure heads, salt concentration at 2 week intervals and crop yields, the model was found suitable for use in the region. A few nomographs were prepared to provide a graphical method to predict the effect of different combinations of water quality and depth of water application on crop yield and soil salinity and to...
2008-01-01
British Library Electronic Table of Contents (United Kingdom)
The use of numerical modeling in oil spill incidents is a well established technique that has proven to provide cost-effective and reasonable estimates of oil surface drift. Good predictability of such models depends highly on the quality of the input data of the incident and on the model calibration effort. This paper presents the results of simulating oil spillage trajectory in the Arabian (Persian) Gulf. The study employed a 3-D rectilinear hydrodynamic model combined with oil spill model. Typical representative environmental conditions of the Arabian Gulf were first setup into a hydrodynamic circulation model using data from various sources. The performance of the hydrodynamic model was then tested against measurements of tidal fluctuation and sea currents at selected locations. The sp...
2007-01-01
Neutron intensity measurements of BWR spent fuels
International Nuclear Information System (INIS)
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
2000-03-01
Energy Technology Data Exchange (ETDEWEB)
A new luminescent europium probe is presented for the determination of phosphate (P) in microtiter plate format. The assay is based on the quenching of the luminescence of the europium-tetracycline (EuTc) 1:1 complex by phosphate using a reagent concentration of 20.8 {mu}mol/L. The probe is excited at 400 nm and displays a large Stokes' shift of 210 nm. The emission maximum is located at 616 nm. The system works best at neutral pH 7 and is therefore suitable for phosphate determination in biological and biochemical systems. The linear range of the calibration plot is from 5 x 10{sup -6} mol/L to 7.5 x 10{sup -4} mol/L of phosphate, and the limit of detection is 3 {mu}mol/L.
2006-01-12
Methods for probabilistic design of wind turbines
Energy Technology Data Exchange (ETDEWEB)
This report gives a brief introduction to the project `Probabilistic Design Tool for Wind Turbines` - PRODETO - which was carried out during the years 1996-98 with partial funding from the European Commission under the Non-Nuclear Energy Programme JOULE III. The report gives an overview of the objectives and motivation for the project, and the methodology used. In this context, an example of reliability-based wind turbine design against fatigue failure is outlined with emphasis on the various important steps herein, which include probabilistic load and resistance modelling, calculation of failure probability, and calibration of partial safety factors for use with a deterministic design code format. The results of the project are presented with emphasis on a developed computer program and its capabilities, and the various elements of an executed case study are outlined. A list of project reports concludes the report. (au)
1998-12-01
Measurement of the ratio of liquid to solid phases in a continuous ingot
International Nuclear Information System (INIS)
A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would permit to exercise ...
Energy Technology Data Exchange (ETDEWEB)
The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
This report describes the results made in fulfillment of contract DE-FG26-02NT15451, ''Multicomponent Seismic Analysis and Calibration to Improve Recovery from Algal Mounds: Application to the Roadrunner/Towaoc Area of the Paradox Basin, Ute Mountain Ute Reservation, Colorado''. Optimizing development of highly heterogeneous reservoirs where porosity and permeability vary in unpredictable ways due to facies variations can be challenging. An important example of this is in the algal mounds of the Lower and Upper Ismay reservoirs of the Paradox Basin in Utah and Colorado. It is nearly impossible to develop a forward predictive model to delineate regions of better reservoir development, and so enhanced recovery processes must be selected and designed based upon data that can quantitatively or qualitatively distinguish regions of good or bad reservoir permeability and porosity between existing well control. Recent advances in seismic ...
2003-07-10
Energy Technology Data Exchange (ETDEWEB)
The preparation and luminescence properties of crystal phosphors based on alkali metal iodide and calcium oxide substrates were studied. The highest luminescence intensities were achieved with iodide substrates at 200/sup 0/ and with the calcium oxide substrate at 800/sup 0/. The calibration graphs were linear in the thallium concentration ranges 0.03-5.0 and 0.1-2.0 mu g using sodium and potassium oxides, respectively, and in the range 0.05-5 mu g using cesium iodide and calcium oxide. A method is proposed for the determination of down to 3 x 10/sup -4/% thallium in rocks, using a crystal phosphor with sodium iodide substrate.
1986-02-01
Theoretical and experimental research efforts in evaluating an innovative concept for vertical axis wind turbines (VAWT) are described. The concept is that of using straight blades composed of circulation controlled airfoil sections. The theoretical analysis has been developed to determine the unsteady lift and moment characteristics of multiple-blade cross-flow wind turbines. To determine the drag data needed as input to the theoretical analysis, an outdoor test model VAWT has been constructed; design details, instrumentation, and calibration results are reported. Initial testing is with fixed pitch blades having cross-sections of conventional symmetrical airfoils. Costs of building the test model are included, as well as estimates for blades constructed with composite materials. These costs are compared with those of other types of wind turbines.
1978-10-01
Energy Technology Data Exchange (ETDEWEB)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
1991-01-01
International Nuclear Information System (INIS)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
Improving functional esophageal surgery with a ?smart? bougie: endoflip
British Library Electronic Table of Contents (United Kingdom)
Background An emerging imaging tool, the functional lumen imaging probe (Endoflip; Crospon Ltd, Galway, Ireland), provides a real-time measurement of esophagogastric junction (EGJ) capacity and diameter, which would be of particular interest in functional esophageal surgery such as Heller myotomy and antireflux procedures. This study aimed to demonstrate the intraoperative use of endoflip in the treatment of achalasia and gastroesophageal reflux disease (GERD). Methods In the first case, Heller myotomy was performed under endopflip guidance, for persistent dysphagia after failed endoscopic dilatation. In the second case, the endoflip was used to calibrate a Nissen fundoplication. With the patient under general anesthesia, the endoflip catheter was inserted orally and positioned to straddle...
2011-01-01
Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.
Energy Technology Data Exchange (ETDEWEB)
An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.
1998-09-11
Hybrid Camera Surveillance System Using Robust Human Detection
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
2007-01-01
G factors and lifetimes for 2/sub 1//sup +/ states of sup(84,86,88)Sr
Energy Technology Data Exchange (ETDEWEB)
The g factors of the 2/sub 1//sup +/ states in sup(84,86,88)Sr have been deduced using the thin-foil transient field technique with the field calibration of the Rutgers group. The values are g(/sup 84/Sr)= + 0.419(47), g(/sup 86/Sr)= + 0.273(50) and g(/sup 88/Sr)= + 1.15(17). The mean lifetimes of the 2/sub 1//sup +/ states in sup(86,88)Sr were determined by the Doppler-shift attenuation method to be 2.10(22) ps and 0.219(23) ps respectively. The g factor and lifetime results are compared with shell model and interacting boson model predictions.
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.
1988-01-01
Flexible, all-organic ammonia sensor based on dodecylbenzene sulfonic acid-doped polyaniline films
International Nuclear Information System (INIS)
A stable chlorobenzene dispersion of conducting polyaniline (PANI) has been obtained by doping emeraldine base with dodecylbenzene sulfonic acid (DBSA) and studied by spectrophotometric measurements in the UV-vis-IR range. The electrical properties of PANI: DBSA films obtained from the above dispersion have been investigated under different temperature and relative humidity conditions. All-organic chemoresistive devices have been developed by spin-coating the PANI: DBSA dispersion on flexible substrates, and then by depositing electrodes on the top, from a carbon nanotube conducting ink. Sensing tests performed under exposition to calibrated amounts of ammonia reveal that these simple and inexpensive sensors are able to detect ammonia at room temperature in a reliable way, with a sensitivity linearly related to concentration in the range between 5 ppm and 70 ppm.
2010-09-30
Fitness of equipment used for medical exposure to ionising radiation
Energy Technology Data Exchange (ETDEWEB)
The purpose of this note is to provide guidance to those who have duties under the Health and Safety at Work Act and other relevant legislation. It gives guidance on the practical application of legislation, concerning radiotherapy equipment. Two particular issues arise out of the requirements of Regulation 33 of the Ionising Radiations Regulations 1985 (IRR85) in relation to equipment which is used for medical exposures. These are the requirement to select, install and maintain this type of equipment in such a way that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person where this is compatible with the intended clinical purpose, including the need to ensure that equipment used for radiotherapy is properly calibrated, and the requirement to notify the Health and Safety Executive (HSE) when an incident occurs involving a malfunction or defect in any 'radiation equipment' which gives rise to a medical ...
1992-05-01
Estimated fetal radiation dose from multislice CT studies
International Nuclear Information System (INIS)
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.
Drug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation
British Library Electronic Table of Contents (United Kingdom)
Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...
2011-01-01
Double peak effect in microdosimetric proportional counters and its interpretation
Energy Technology Data Exchange (ETDEWEB)
In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.
1989-01-01
International Nuclear Information System (INIS)
TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.
1999-05-01
British Library Electronic Table of Contents (United Kingdom)
Background: Superficial inferior epigastric artery (SIEA) flap has a great advantage over other flaps of the area, that is, readily non-existent donor-site problems. The main reason why the SIEA flap has never been extensively used in breast reconstruction is the small diameter and variable anatomy of its donor artery. This study presents a possibility of enlarging the SIEA diameter using the delay-phenomenon mechanism. Methods: A prospective clinical study of 26 patients was undertaken. Prior to surgery, ultrasound examinations were performed, measuring the diameter of SIEA and the velocity of blood flow in SIEA. The ipsilateral deep inferior epigastric artery (DIEA) was then ligated in all patients who had a measurable SIEA preoperatively. Two weeks later, measurements were repeated. The...
2011-01-01
Continuous emission monitoring and quality assurance requirements for new power plants
International Nuclear Information System (INIS)
Electric utility plants, for which construction commenced after September 18, 1978, must install and operate continuous emission monitoring (CEM) systems to demonstrate compliance with SO_2 and NO_x emission standards. Furthermore, effective December 4, 1987, each plant must develop and implement a CEM quality assurance (QA) program. This paper reviews the CEM and QA requirements set forth by new source performance standards (NSPS) promulgated by the Environmental Protection Agency. The paper summarizes operating characteristics of the 32 power plants currently subject to NSPS and describes the types of CEM systems used by these plants. Also, to the extent available, the paper presents the results of initial (i.e., first quarter 1988) QA activities (e.g., audits and calibration drift assessments) conducted by these plants.
1988-09-25
International Nuclear Information System (INIS)
The Cycle 8A static tests conducted in the Fast Flux Test Facility (FFTF) during 1986 have resulted in the separation of various feedback reactivity components. These feedback components, described by closed-form equations depending only on the reactor temperature field, can be regarded as database for the validation and/or calibration of feedback mechanistic models. The SASSYS safety analysis code contains the most developed feedback reactivity models and was selected for the comparison study between database and mechanistic calculations for the FFTF. Although detailed feedback models for control rod repositioning and core radial expansion/bowing exist, only the simple models were available in SASSYS at the time of this study. The results are described in this paper.
1988-05-01
Calorimetric sensors for energy deposition measurements
Energy Technology Data Exchange (ETDEWEB)
A calorimetric sensor with several novel design features has been developed. These sensors will provide an accurate sampling of thermal power density and energy deposition from proton beams incident on target components of accelerator-based systems, such as the Accelerator Production of Tritium Project (APT) and the Spallation Neutron Source (SNS). A small, solid slug (volume = 0.347 cc) of target material is suspended by kevlar fibers and surrounded by an adiabatic enclosure in an insulating vacuum canister of stainless steel construction. The slug is in thermal contact with a low-mass, calibrated, 100-k{Omega} thermistor. Power deposition caused by the passage of radiation through the slug is calculated from the rate of temperature rise of the slug. The authors have chosen slugs composed of Pb, Al, and LiAl.
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The Jeanne d`Arc Basin is located 320 km offshore in the Grand Banks of Newfoundland. It is a Mesozoic failed-rift basin with recoverable oil reserves of about 2 billion barrels. Its huge Hibernia Field will be in production by late 1997. The basin has been reappraised using sequence stratigraphic concepts, and renewed exploration in the area is expected. The Upper Jurassic - Lower Cretaceous sedimentary accumulation in the Basin was formed by the extensional tectonics that created the North Atlantic Ocean. The sedimentary packages were placed in chronostratigraphic order by calibrating the biostratigraphy of the Oxfordian to Maastrichtian section to the detailed ammonite zonation from the North Sea.
1997-09-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this study is to develop the methodology which enables to identify the mechanical properties of element such as stress intensity factor by using the AE parameters. Considering the multivariate and nonlinear properties of AE parameters such as ringdown count, rise time, energy, event duration and peak amplitude from fatigue cracks of machine element the principal component regression(PCR) and artificial neural network(ANN) models for the estimation of stress intensity factor were developed and validated. The AE parameters were found to be very significant to estimate the stress intensity factor. Since the statistical values including correlation coefficients, standard mr of calibration, standard error of prediction and bias were stable, the PCR and ANN models for stress intensity factor were very robust. The performance of ANN model for unknown data of stress intensity factor was better than that of PCR model
2001-02-15
Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration
Energy Technology Data Exchange (ETDEWEB)
Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous ...
2009-07-23
International Nuclear Information System (INIS)
This study is concerned to the perforation phenomena of the oblique dual-plate by projectile. Experiment and simulation related to that was carried out. the variables considered in this phenomena include the electrolytic zinc coated steel sheet and carbon steel rod. In the former, the confirmation and projectile velocity possible phenomena of real phenomena is done, the latter, the effect of parameter such as time-step and grid space length is analyzed by using the three-dimensional Lagrangian explicit time-integration finite element code, HEMP. This code use the eight node hexahedral elements and in this study, Von-Mises Criteria is used as the strength model, Mie-Gruneisen is as the Equation of State. The simulation was performed by contrast with the experiment. Through the calibration of the parameter of Lagrangian code, reasonable result was approached.
2004-11-03
A mass action model of the dose-response curve of immunoradiometric assay and its curve fitting
International Nuclear Information System (INIS)
In view of no satisfactory mathematical model is presently available for the dose-response curve of immunoradiometric assay, a three parameter model based on single binding site mass action law has been derived. A curve fitting method based on similar principle of linear robust regression was designed and a software was prepared for use on IBM personal computers. Experiments revealed that the model is applicable to a variety of IRMA systems as well as to time-resolved immunofluorometric assay of hAFP. When there was outlier(s) of the calibration curve, the average bias of unknown samples obtained with this method is significantly smaller than methods using four parameter logistic model or four parameter single site mass action model.
1991 ice jamming along the Saint John River: a case study
Energy Technology Data Exchange (ETDEWEB)
Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the measured shear wall height. 14 refs., 11 figs.
1996-04-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes a 1993 field experiment entitled Marine Aerosol Properties and Thermal Imager Performance Trial (MAPTIP) conducted by NATO AC/243 Panel 04/RSG.8 and 04/RSG.5 in the Dutch coastal waters. Objectives were: to improve and validate vertical marine aerosol models by providing an extensive set of aerosol and meteorological measurements, within a coastal environment at different altitudes and for a range of meteorological conditions; make aerosol and meteorological observations in the first 10 m of the ocean surface with a view to extending existing aerosol models to incorporate near-surface effects; and to assess marine boundary layer effects on thermal Imaging systems. Aerosol and meteorological instruments, as well as thermal imagers and calibrated targets, were utilized. This network of instrumentation has provided a comprehensive database of aerosol size distribution profiles and relevant meteorological variables throughout the marine atmospheric ...
1995-08-01
Energy Technology Data Exchange (ETDEWEB)
The K site near Seoul began landfilling in 1992. The landfilled wastes include municipal solid waste (66.4%), construction residues (20.4%), water and wastewater sludges (trace levels), and hazardous waste (trace levels). The water content of the municipal solid waste is very high (47.3%); as a result, the leachate level (average E.L.) of the landfill, the design value of which is 7.0 m, was measured at 10.3 m in January 1995 and is increasing. The increase of leachate level in the landfill site causes a problem with slope stability. The leachate level at each disposal stage divided by the intermediate cover layer was calculated with the HELP (Hydrologic Evaluation of Landfill Performance) model and calibrated with the data measured from February 1993 to June 1995. Also, the hydraulic conductivities of the waste layer and the intermediate cover layer in each stage were calibrated continuously with HELP model analysis. To verify these results, ...
1996-12-31
Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill
Energy Technology Data Exchange (ETDEWEB)
Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner than high resolution; in high resolution, individual waves are imaged and the ...
1997-06-01
Radon emanation and soil moisture effects on airborne gamma-ray measurements
Energy Technology Data Exchange (ETDEWEB)
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay ...
1997-09-01
Radon emanation and soil moisture effects on airborne gamma-ray measurements
International Nuclear Information System (INIS)
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was attributed to the lower radon emanation of the more coarse-grained sandy soils compared to finer-grained clay ...
Energy Technology Data Exchange (ETDEWEB)
The aim of the thesis is to validate concepts used in hydrocarbon generation and migration models; the model considered is the Temispack model developed by IFP, and the validation is based on the investigation of the thermal and hydraulic evolution in various sedimentary basins. It is shown that, in general, the thermal history of sediments is influenced by external processes (sedimentation rates, lithology, climate changes, regional-scale groundwater circulations) which frequently overprint internal processes (variations of crustal/mantle heat flow). It is found that external processes can frequently explain past thermal events that were erroneously attributed to internal causes (tectonic-thermal events). The origin of over-pressures in young basins with high sedimentation rates is shown to be generally related to compaction disequilibrium. Shale permeability values calibrated against overpressure profiles are consistent with experimental constraints. Compaction ...
1997-07-10
Metastability and dynamics of the shock-induced phase transition in iron
Energy Technology Data Exchange (ETDEWEB)
The shock-induced {alpha}(bcc){r_arrow}{var_epsilon}(hcp) transition in iron begins at 13 GPa on the Hugoniot. In the two-phase region above 13 GPa, the Hugoniot lies well above the equilibrium surface defined by G{sub {alpha}}=G{sub {var_epsilon}}, with G the Gibbs free energy. Also, the phase transition relaxation time {tau} is uncertain, with estimates ranging from {lt}50 ns to {approx}180 ns. Here we present an extensive study of these important aspects, metastability and dynamics, of the {alpha}-{var_epsilon} transition in iron. Our primary theoretical tools are (a) accurate theoretically based free energies for {alpha} and {var_epsilon} phases of iron and (b) accurate calculations of the wave evolution following planar impacts. We define metastable surfaces for forward and reverse transitions by the condition that the thermodynamic driving force G{sub {alpha}}{minus}G{sub {var_epsilon}} is just balanced by an opposing force resulting from elastic stresses, and we ...
1997-02-01
Energy Technology Data Exchange (ETDEWEB)
Continental facies of Scythian-early Anisian age (Buntsandstein) of East of the Paris Basin form the underground gas storage reservoir exploited by Gaz de France in the area of Nancy (east of France). An accurate sedimentological study and the application of Genetic Stratigraphy principles lead to the understanding of the deposition of fluvial, which form the reservoirs, and to the reconstruction of their geometries. The subsurface data are calibrated on outcrops. Three types of fluvial systems (braided, sinuous to straight and anastomosed) are defined. A special focus on anastomosed channels permits to differentiate a proximal and a distal facies. Study of laterally continuous outcrops induces recurrent cycles of thickness, velocity and time variations (few tens to hundred ka). These correspond to the highest frequence stratigraphic units, i.e. parasequences or genetic units. Maximum of channel and levee presentation occurs during base-level rise: base-level fall ...
1995-08-01
Future needs and requirements for AMS "1"4C standards and reference materials
International Nuclear Information System (INIS)
"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth International ...
2004-08-01
Energy Technology Data Exchange (ETDEWEB)
The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document ...
2009-11-01
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
1977-12-09
Constitutive modeling of a nickel base superalloy -with a focus on gas turbine applications
Energy Technology Data Exchange (ETDEWEB)
Gas turbines are used where large amounts of energy is needed, typically as engines in aircraft, ferries and power plants. From an efficiency point of view it is desirable to increase the service temperature as much as possible. One of the limiting factors is then the maximum allowable metal temperatures in the turbine stages, primarily in the blades of the first stage, that are exposed to the highest gas temperatures. Specially designed materials are used to cope with these severe conditions, such as the nickel base superalloy IN792. In order to be able to design the components for higher temperatures and tighter tolerances, a detailed understanding and computationel models of the material behaviour is needed. The models presented in this work have been developed with the objective of being physically well motivated, and with the intention of avoiding excessive numbers of parameters. The influence of the parameters should also be as easy as possible to interpret. The models are to ...
2003-05-01
Calibration of cylindrical detectors using a simplified theoretical approach
Energy Technology Data Exchange (ETDEWEB)
The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical ...
2006-09-15
Energy Technology Data Exchange (ETDEWEB)
A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric ...
2009-09-11
Activity patterns in a panel of outdoor workers exposed to oxidant pollution
Energy Technology Data Exchange (ETDEWEB)
We investigated summer activity patterns in a panel of volunteers drawn from a population segment with potentially high exposure to ambient oxidant pollution. The subjects were 15 men and 5 women aged 19-50, all of whom worked outdoors in the Los Angeles area at least 10 hr per week. The general approach was to (i) calibrate the relationship between ventilation rate (VR) and heart rate (HR) for each subject in controlled exercise; (ii) have subjects monitor their own normal activities with diaries and electronic HR recorders; (iii) estimate VR from HR recordings; and (iv) relate VR with diary descriptions of activities. Calibration data were fit to the equation log (VR) = (intercept) + (slope x HR), intercept and slope being determined separately for each individual to provide a specific equation to predict her/his VR from measured HR. Individuals' correlation coefficients relating log (VR) with HR ranged from 0.83 to 0.95. Subjects ...
1991-10-01
Energy Technology Data Exchange (ETDEWEB)
SKB is currently performing site investigations at two potential sites for a final repository for spent nuclear fuel. This report presents results of water flow and solute transport modelling of the Forsmark site. The modelling reported in this document focused on the near-surface groundwater, i.e. groundwater in Quaternary deposits and shallow rock, and surface water systems, and was performed using the MIKE SHE tool. The most recent site data used in the modelling were delivered in the Forsmark 2.3 dataset, which had its 'data freeze' on March 31, 2007. The present modelling is performed in support of the final version of the Forsmark site description that is produced during the site investigation phase. In this work, the hydrological modelling system MIKE SHE has been used to describe near-surface groundwater flow and the contact between groundwater and surface water at the Forsmark site. The surface water system at Forsmark is described with the one-dimensional ...
2008-09-15
Energy Technology Data Exchange (ETDEWEB)
In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE)-Carlsbad Field Office (CBFO) has developed draft documentation to present the proposed Waste Isolation Pilot Plant (WIPP) remote-handled (RH-) transuranic (TRU) waste characterization program to its regulators, the U.S. Environmental Protection Agency and the New Mexico Environment Department. Compliance with Title 40, Code of Federal Regulations, Parts 191 and 194; the WIPP Land Withdrawal Act (PL 102-579); and the WIPP Hazardous Waste Facility Permit, as well as the Certificates of Compliance for the 72-B and 10-160B Casks, requires that specific waste parameter limits be imposed on DOE sites disposing of TRU waste at WIPP. The DOE-CBFO must control the sites' compliance with the limits by specifying allowable characterization methods. As with the established WIPP contact handled TRU waste characterization program, the DOE-CBFO has proposed a Remote-Handled TRU Waste Acceptance ...
2002-02-26
Waste reduction at the Savannah River Site
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site (SRS) is a key installation for the production and research of nuclear materials for national defense and peace time applications and has been operating a full nuclear fuel cycle since the early 1950s. Wastes generated include high level radioactive, transuranic, low level radioactive, hazardous, mixed, sanitary, and aqueous wastes. Much progress has been made during the last several years to reduce these wastes including management systems, characterization, and technology programs. The reduction of wastes generated and the proper handling of the wastes have always been a part of the Site's operation. This paper summarizes the current status and future plans with respect to waste reduction to waste reduction and reviews some specific examples of successful activities.
1990-01-01
Waste reduction at the Savannah River Site
Energy Technology Data Exchange (ETDEWEB)
The Savannah River Site (SRS) is a key installation for the production and research of nuclear materials for national defense and peace time applications and has been operating a full nuclear fuel cycle since the early 1950s. Wastes generated include high level radioactive, transuranic, low level radioactive, hazardous, mixed, sanitary, and aqueous wastes. Much progress has been made during the last several years to reduce these wastes including management systems, characterization, and technology programs. The reduction of wastes generated and the proper handling of the wastes have always been a part of the Site`s operation. This paper summarizes the current status and future plans with respect to waste reduction to waste reduction and reviews some specific examples of successful activities.
1990-12-31
Waste Receiving and Processing Facility Module 2A: Advanced Conceptual Design Report. Volume 1
Energy Technology Data Exchange (ETDEWEB)
This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.
1994-03-01
Vibration experiment for a three-loop PWR reactor building
International Nuclear Information System (INIS)
Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparison, the adequacy of the analytical method employed for the design was confirmed. (Aoki, K.).
1983-01-01
Utilities feel weight of burden caused by EMF fears
Studies on the effects of electromagnetic fields (EMF)on human health have been conducted for more than 20 years. None have categorically established or eliminated any connection between EMF and adverse health effects. Nonetheless, 96% of the risk managers working in the utility sector view EMF as an over-riding concern. Public concern over EMF has erupted into legal, as well as regulatory, actions. To date, some utilities have had lawsuits brought against them by customers who claim they developed cancer as a result of nearby high-voltage transmission lines. What`s more, a small handfull of cities have adopted ordinances that specifically limit where and how utilities handle the placement of their transmission lines.
1995-10-01
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.
2003-05-01
Two stents insertion via single tract for treatment of hepatic hilar cholangiocarcinoma
International Nuclear Information System (INIS)
Objective: To evaluate the feasibility and clinical application of two stents insertion via single tract for treatment of hepatic hilar cholangiocarcinoma. Methods: Eighteen patients with hepatic hilar cholangiocarcinoma who had left and right bile duct obstruction were treated with stents insertion via right bile duct puncturing routeway. These two stents were implanted between right and left bile duct, and between right bile duct and common bile duct. Results: Eighteen patients obtained successful two stents placement by right bile duct puncturing tract and succeeded with internal drainage for all biliary tree jaundice subsided distinctly. Conclusions: The technique of two stents insertion via single tract could predigest interventional drainage procedure of high bile duct obstruction, reduce operation trauma, shorten handling time and possess promising application value
2003-12-01
British Library Electronic Table of Contents (United Kingdom)
Scanning electron microscope (SEM) is necessary to demonstrate presence or absence of pit membranes in possible perforations or the type of pit membrane remnants in perforations in vessel element end-walls of angiosperms, but it was unconfirmed and questionable whether pit membrane absence in pits was affected by the processing and handling before SEM observations. To solve this question, the secondary xylem of four woody species from primitive angiosperms, Illicium henryi Diels. (Illiciaceae), Schisandra rubriflora (Franch.) Rehd. et Wils. (Schisandraceae), Tetracentron sinensis Oliv. and Trochodendron aralioides Sieb. & Zucc. (Trochodendraceae) was chosen and the following techniques were used: (1) fresh materials were examined in low-vacuum with ESEM. (2) Air-dried materials were examin...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Background The 2003 outbreak of severe acute respiratory syndrome (SARS) infected over 8000 people and killed 774. Transmission of SARS occurred through direct and indirect contact and large droplet nuclei. The World Health Organization recommended the use of household disinfectants, which have not been previously tested against SARS coronavirus (SARS-CoV), to disinfect potentially contaminated environmental surfaces. There is a need for a surrogate test system given the limited availability of the SARS-CoV for testing and biosafety requirements necessary to safely handle it. In this study, the antiviral activity of standard household products was assayed against murine hepatitis virus (MHV), as a potential surrogate for SARS-CoV. Methods A surface test method, which involves drying an amo...
2009-01-01
The Daya Bay nuclear power plant performance. An example of international cooperation
International Nuclear Information System (INIS)
Technology transfer is an integral part of Framatome's general approach to its Chinese partners for the Daya Bay, Ling Ao, and Qinshan phase 2 nuclear power plant projects. It has been the subject of major operations covering all activities relevant to project management, design and engineering, manufacturing, and maintenance know-how. This presentation is more particularly devoted to nuclear island maintenance knowledge, which has been extensively transferred by Framatome to the Daya Bay plant owner over a period of four years, through a program including the constitution of mixed Franco-Chinese teams to handle plant maintenance, shadow training of Chinese specialists in the maintenance work performed by Framatome or its subcontractors in France, and theoretical training sessions on equipment mockups in China and France. (author)
1998-10-25
The Chernobyl plant shutdown; L'arret de la centrale de Tchernobyl
Energy Technology Data Exchange (ETDEWEB)
The Chernobylsk-1 reactor, operational in september 1977 has been stopped in november 1996; the Chernobylsk-2 reactor started in november 1978 is out of order since 1991 following a fire. The Chernobylsk-3 reactor began in 1981. During the last three years it occurs several maintenance operations that stop it. In june 2000, the Ukrainian authorities decided to stop it definitively on the 15. of december (2000). This file handles the subject. it is divided in four chapters: the first one gives the general context of the plant shutdown, the second chapter studies the supporting projects to stop definitively the nuclear plant, the third chapter treats the question of the sarcophagus, and the fourth and final chapter studies the consequences of the accident and the contaminated territories. (N.C.)
2000-12-01
Surface analysis by Fourier-transform infrared (FTIR) spectroscopy
Energy Technology Data Exchange (ETDEWEB)
A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.
1981-08-12
Separation of lead-203 from cyclotron-bombarded thallium targets by ion-exchange chromatography
Energy Technology Data Exchange (ETDEWEB)
A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 ..mu..g of thallium and less than 0.1 ..mu..g of copper remain in the lead-203 fraction.
1982-07-01
Separation of lead-203 from cyclotron-bombarded thallium targets by ion-exchange chromatography
International Nuclear Information System (INIS)
A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 #mu#g of thallium and less than 0.1 #mu#g of copper remain in the lead-203 fraction. (author).
Safety philosophy and concepts for large liquid metal breeder reactor power plants
International Nuclear Information System (INIS)
This paper addresses the unique related aspects of the LMFBR concept which are of significance to containment design and structural analysis. Topics covered include: Primary boundary integrity assurance; Effects of sodium spills on integrity of structures; Provisions being considered for containment of melted cores; Fuel handling accidents. Specific reference is made to the FFTF and the Clinch River Breeder Reactor Project designs and methods of treatment of the above problems. In particular, the part played by tests, such as those carried out on a simulated FFTF model, and the planned structural reliability and related programs are considered. Where practicable, these topics are addressed in a manner which places FFTF and CRBR in context with other LMFBR's and point to a possible direction for future American LMFBR designs. (Auth.).
Safety philosophy and concepts for large liquid metal breeder reactor power plants
International Nuclear Information System (INIS)
This paper will adress the unique safety related aspects of the LMFBR concept which are of significance to containment design and structural analyses. Topics to be covered will include: primary boundary integrity assurance; effects of sodium spills on integrity of structures; provisions being considered for containment of melted cores; and fuel handling accidents. Specific reference will be made to the FFTF and the Clinch River Breeder Reactor Project designs and methods of treatment of the above problems. In particular, the part played by tests, such as those carried out on a simulated FFTF model, and the planned structural reliability and related programs will be considered. Where practicable, these topics will be addressed in a manner which places FFTF and CRBR in context with other LMFBR's, and will point to a possible direction for future American LMFBR designs.
1975-09-01
Re-Engineering Casting Production Systems - Final Report - 03/02/1998 - 03/01/2001
Energy Technology Data Exchange (ETDEWEB)
The goal of this three-year project was to improve the production systems in use by steel foundries in the United States. Improvements in the production systems result in less rework, less scrap, and less material handling, all of which would significantly reduce the energy demands of the process. Furthermore, these improvements would allow the companies to be more competitive, more responsive to customers' needs, deliver products with less lead time and require less capital. The ultimate result is a stronger domestic steel casting industry, which uses less energy. A major portion of this research involved the deployment of student researchers at steel foundries, to study their production systems and collect data.
2001-06-25
Energy Technology Data Exchange (ETDEWEB)
Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.
1982-01-01
Point-splitting regularization of composite operators and anomalies
The point-splitting regularization technique for composite operators is discussed in connection with anomaly calculation. We present a pedagogical and self-contained review of the topic with an emphasis on the technical details. We also develop simple algebraic tools to handle the path ordered exponential insertions used within the covariant and non-covariant version of the point-splitting method. The method is then applied to the calculation of the chiral, vector, trace, translation and Lorentz anomalies within diverse versions of the point-splitting regularization and a connection between the results is described. As an alternative to the standard approach we use the idea of deformed point-split transformation and corresponding Ward-Takahashi identities rather than an application of the equation of motion, which seems to save the complexity of the calculations.
2000-01-01
Personal Information Databases
One of the most important aspects of security organization is to establish a framework to identify security significant points where policies and procedures are declared. The (information) security infrastructure comprises entities, processes, and technology. All are participants in handling information, which is the item that needs to be protected. Privacy and security information technology is a critical and unmet need in the management of personal information. This paper proposes concepts and technologies for management of personal information. Two different types of information can be distinguished: personal information and nonpersonal information. Personal information can be either personal identifiable information (PII), or nonidentifiable information (NII). Security, policy, and technical requirements can be based on this distinction. At the conceptual level, PII is defined and formalized by propositions over infons (discrete pieces of information) that ...
2009-01-01
Novel Processing of Unique Ceramic-Based Nuclear Materials and Fuels
Energy Technology Data Exchange (ETDEWEB)
Advances in nuclear reactor technology and the use of gas-cooled fast reactors require the development of new materials that can operate at the higher temperatures expected in these systems. These include refractory alloys base on Nb, Zr, Ta, Mo, W, and Re; ceramics and composites such as those based on silicon carbide (SiCf-SiC); carbon-carbon composites; and advanced coatings. Besides the ability to handle higher expected temperatures, effective heat transfer between reactor componets is necessary for improved efficiency. Improving thermal conductivity of the materials used in nuclear fuels and other temperature critical components can lower the center-line fuel temperature and thereby enhance durability and reduce the risk of premature failure.
2008-11-30
Neural integrated control for a free-floating space robot with suddenly changing parameters
British Library Electronic Table of Contents (United Kingdom)
Because the state of a free-floating space robot model is uncertain and sudden changes in the model parameters might undermine the stability of the system, this paper proposes a control strategy based on a variable structure neural integrated controller. This scheme does not need a precise space robot model, making use of the radial basis function neural network ability approach to learn about an uncertain model. The network weights are adjusted online in real-time. During the early period of the control phase and parameter changes, the variable structure controller compensates for the uncertain model which the neural network could not learn well. It also creates global asymptotic stability for the whole closed-loop system. Simulation results show that the controller can handle bad changea...
2011-01-01
Mulled coal: A beneficiated coal form for use as a fuel or fuel intermediate
Energy Technology Data Exchange (ETDEWEB)
Energy International is developing a technology that will create a staged formulation with the first coal form (Mulled Coal) that can be stored, transported, and pumped. Just prior to combustion, the Mulled Coal (MC) would be modified to provide the properties needed for proper atomization. This concept is an alternative to the expensive and energy intensive thermal drying processing of fine coal wet cakes. The material is suitable for both direct feed use in conventional and fluid bed combustors as well as on-site conversion to combustible slurries. By maintaining the coal form relatively close to the feed wet cake, only minor processing with low additive levels and low energy blending needed at the point of production. Its conversion to slurry or other use-feed form is made near the time of use and thus the requirements for stability, climatic control, and other storage, transport, and handling requirements are much less severe.
1991-10-01
Meteorological measurement methods and diffusion models for use at coastal nuclear reactor sites
Energy Technology Data Exchange (ETDEWEB)
A study, based on a literature review was made to examine currently recommended meteorological measurement programs and diffusion prediction methods for nuclear power plants to determine their adequacy for plants located in coastal zones. Although procedures for handling the near-worst case (stable, light-wind situation) were judged adequately conservative, deficiencies in guidelines and procedures were found with respect to the following: failure to consider the role of coastal internal boundary layers; specifications for tower locations and instrument heights; methods of classifying atmospheric stability; methods of allowing credit for plume meander, and models specified for diffusion calculations. Recommendations were made for changes in the guidelines applicable to these topics. Areas in which additional research is needed were identified.
1980-11-01
Energy Technology Data Exchange (ETDEWEB)
Studies continued on organic tracers for use as hydrologic tracers as part of the Yucca Mountain Site Characterization project. This subject report for the quarter 01/01/93 through 03/31/93 discusses the following issues: project organization and responsibilities; quality assurance program; design control; procurement document control; instructions, procedures, and drawings; document control; control of purchased items and services; identification and control of items; control of processes; inspection; test control; control of measuring and test equipment; handling, storage, and shipping; inspection, test, and operating status; control of nonconforming items and conditions; corrective action; quality assurance records; audits; software quality assurance; and scientific investigation.
1993-02-25
Government-industry-education collaboration for intelligent tutor computer labs
Energy Technology Data Exchange (ETDEWEB)
Through the dedicated collaborative efforts of many individuals interested in supporting local education, computer laboratories were established at two urban high schools. The purchasing and implementation of the project was handled by the Alliance for Education, a local non-profit education advocate. Funds were supplied by the Air Force as part of a 3-year research activity utilizing artificial intelligence technology to tutor 9th grade students. NCR (now AT7T Global Information Solutions) corporate leaders provided the computers and network equipment at a considerable savings to the project. Each lab is a state-of-the-art facility with air-conditioning, carpeting, special computer tables, computer projection screens, and on-site technical support. Student and teacher enthusiasm toward the project has been gratifying and quantitative results are currently being evaluated for both attitude, skills, and state proficiency tests.
1994-12-31
Global Existence of Weak Solutions to a Nonlocal Cahn-Hilliard-Navier-Stokes System
A well-known diffuse interface model consists of the Navier-Stokes equations nonlinearly coupled with a convective Cahn-Hilliard type equation. This system describes the evolution of an incompressible isothermal mixture of binary-fluids and it has been investigated by many authors. Here we consider a variant of this model where the standard Cahn-Hilliard equation is replaced by its nonlocal version. More precisely, the gradient term in the free energy functional is replaced by a spatial con- volution operator acting on the order parameter phi. Therefore the coupling with the Navier-Stokes equations is difficult to handle even in two spatial dimensions because of the lack of regularity of phi. We establish the global existence of a weak solution.
2011-01-01
Geometry of elastic hydrofracturing by injection of an over pressured non-Newtonian Fluid
The nucleation and propagation of hydrofractures by injection of over pressured fluids in an elastic and isotropic medium are studied experimentally. Non-Newtonian fluids are injected inside a gelatine whose mechanical properties are assumed isotropic at the experimental strain rates. Linear elastic theory predicts that plastic deformation associated to breakage of gelatin bonds is limited to a small zone ahead of the tip of the propagating fracture and that propagation will be maintained while the fluid pressure exceeds the normal stress to the fracture walls (Ch\\'avez-\\'Alvarez,2008) (i.e., the minimum compressive stress), resulting in a single mode I fracture geometry. However, we observed the propagation of fractures type II and III as well as nucleation of secondary fractures, with oblique to perpendicular trajectories with respect to the initial fracture. In the Video (http://hdl.handle.net/1813/14122) experimental evidence shows that the fracture shape ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Reactive chemical transport models developed over the past decade have generally relied on the assumption that local thermodynamic equilibrium is achieved at all times between aqueous species in a given system. Consequently, homogeneous aqueous systems characterized by a number of kinetically slow reactions, particularly problems involving organic species, cannot be satisfactorily modeled. In this study, we present a prototype computer model, KINETRAN, which is designed to handle kinetically-controlled homogeneous reactions in the aqueous phase, along with the transport of the various species involved, through geologic media. 31 refs., 53 figs., 10 tabs.
1990-05-01
Evaluating coal processing technology for the Indian power industry
Energy Technology Data Exchange (ETDEWEB)
Due to the ever-increasing demand for electric power in India, the production of steam (non-coking) coal will continuously increase. Since most Indian coals contain high ash-forming minerals which result in the increased costs of transportation, boiler maintenance and refuse handling, the use of pre-combustion washing becomes a viable concept. However, many professionals in the Indian mining industry have debated on which of the many benefication techniques is the most appropriate for the pre-combustion cleaning. Through the comprehensive study presented herein, it is found that heavy media separation is more suitable than the jig process for most of the Indian coals. A discussion and flowsheet for the state-of-the-art plant design called the High Capacity Processor (HCP) using advanced coal cleaning techniques are presented.
1996-12-31
Establishing parameters to evaluate the physical and mechanical properties of coke
Degradation of blast furnace coke during handling and transport can produce up to 5% of -10 mm size and so reduce the +80 mm component to less than 2-4%. In shatter tests the action is one of crushing, creating smaller pieces out of a large piece and so, in effect, increasing uniformity and strength. Different size cokes differ in strength and physico-chemical properties, and are also affected by the quenching method (wet or dry) used. The most important parameter as far as blast furnace coke is concerned, in the interests of uniform size and sustained strength, is the M10 index, showing the yield of -10 mm fines, as it is these which detract from furnace performance. (9 refs.)
1982-01-01
Equipment hardening and hardness assurance
International Nuclear Information System (INIS)
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the essential features of the radiation hardening of large assemblies of equipment and how effective control of ...
Engineering TCP transmission and retransmission mechanisms for wireless networks
British Library Electronic Table of Contents (United Kingdom)
Transmission Control Protocol (TCP) provides mechanisms for reliable data communications. Although it works well in wired networks, it fails to offer satisfactory performance in lossy and wireless environments. And in the multi-hop wireless infrastructure, packet delivery suffers high cumulative loss rate if traveling over multiple wireless hops. The Selective acknowledgment (SACK) is one header option that might be used to combat segment corruptions in air channels. In this paper, an alternative set of flow control mechanisms is proposed to handle high packet loss rate in a wireless medium. Using a measurement-based mechanism, sustainable segment delivery is achievable through a novel size-reduction method. Multiple segment retransmission mechanisms are introduced to reduce successive tim...
2011-01-01
Efficient Multiclass Implementations of L1-Regularized Maximum Entropy
This paper discusses the application of L1-regularized maximum entropy modeling or SL1-Max [9] to multiclass categorization problems. A new modification to the SL1-Max fast sequential learning algorithm is proposed to handle conditional distributions. Furthermore, unlike most previous studies, the present research goes beyond a single type of conditional distribution. It describes and compares a variety of modeling assumptions about the class distribution (independent or exclusive) and various types of joint or conditional distributions. It results in a new methodology for combining binary regularized classifiers to achieve multiclass categorization. In this context, Maximum Entropy can be considered as a generic and efficient regularized classification tool that matches or outperforms the state-of-the art represented by AdaBoost and SVMs.
2005-01-01
Dislocation pinning in electron-irradiated copper as a function of electron energy and irradiation
Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeV electrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)
1973-01-01
Energy Technology Data Exchange (ETDEWEB)
A pipeless batch plant is a batch processing production system using mobile vessels. The plant performances depend on both hardware of equipment and software of operation. So the plant includes many design factors such as number of vessels, stations and AGVS, layout of stations, vessel moving rules, job scheduling and so on. In this paper, the characteristics of pipeless batch plant design are considered to handle the problem by the systems engineering approach. Then, a practical design method known as design-by-analysis is applied to solve such a complex design problem. Based on this concept, a design support system composed of modeling, simulation and evaluation subsystems is developed. This system enables rational decision making through performance evaluation for proposed design of a pipeless batch plant. The usefulness of the system is illustrated by industrial examples. 12 refs., 8 figs., 6 tabs.
1997-07-10
Development of a 1D neutron transport code employing the method of characteristics
International Nuclear Information System (INIS)
To investigate the 2D/1D fusion core analysis method, a 1D neutron transport problem solver, PEACH-ID, is developed. It is a code of method of characteristics (MOC), both the usual fiat-source step characteristics (SC) scheme and linear source (LS) approximation scheme are adopted for tracking calculation along the neutron flying trajectory. Exponential function interpolation table and fission source extrapolation are adopted as two major methods to accelerate the computational process. Numerical results demonstrate that PEACH-1D is accurate and efficient, and the proposed LS scheme is able to handle quite larger mesh division and deserves much more application in the MOC codes. (authors)
2009-09-01
Development of Ultra-Fast Silicon Switches for Active X-Band High Power RF Compression Systems
Energy Technology Data Exchange (ETDEWEB)
We present the recent results of our research on the high power ultra-fast silicon RF switches. This switch is composed of a group of PIN diodes on a high purity silicon wafer. The wafer is inserted into a cylindrical waveguide under TE{sub 01} mode, performing switching by injecting carriers into the bulk silicon. Our current design uses a CMOS compatible process and the device was fabricated at SNF (Stanford Nanofabrication Facility). 300 ns switching time has been observed, while the switching speed can be improved further with 3-D device structure and faster driving circuit. Power handling capacity of the switch is at the level of 10 MW. The switch was designed for active X-band RF pulse compression systems--especially for NLC, but it is also possible to be modified for other applications and other frequencies.
2006-03-06
The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO/sub 2/ streams that currently are not being captured. Physical layout of the smelter and the surrounding area is presented, along with existing control equipment. Ductwork that would be considered for future system tie-in is defined. Emissions from operating equipment, gas flow rates, temperatures, sulfur balance, and a process flow sheet are included. Utilities, stack dimensions, footing requirements, and solid waste handling are defined. Available area for new control equipment, gas characteristic variation, and potential new control equipment installation problems are discussed. Portions of this document are not fully legible. (GRA)
1976-02-01
The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO/sub 2/ streams that currently are not being captured. Physical layout of the smelter and the surrounding area is presented, along with existing control equipment. Ductwork that would be considered for future system tie-in is defined. Emissions from operating equipment, gas flow rates, temperatures, sulfur balance, and a process flow sheet are included. Utilities, stack dimensions, footing requirements, and solid waste handling are defined. Available area for new control equipment, gas characteristic variation, and potential new control equipment installation problems are discussed. (GRA)
1976-02-01
Decider: A fuzzy multi-criteria group decision support system
British Library Electronic Table of Contents (United Kingdom)
Multi-criteria group decision making (MCGDM) aims to support preference-based decision over the available alternatives that are characterized by multiple criteria in a group. To increase the level of overall satisfaction for the final decision across the group and deal with uncertainty in decision process, a fuzzy MCGDM process (FMP) model is established in this study. This FMP model can also aggregate both subjective and objective information under multi-level hierarchies of criteria and evaluators. Based on the FMP model, a fuzzy MCGDM decision support system (called Decider) is developed, which can handle information expressed in linguistic terms, boolean values, as well as numeric values to assess and rank a set of alternatives within a group of decision makers. Real applications indic...
2010-01-01
Data Management and Mining in Astrophysical Databases
We analyse the issues involved in the management and mining of astrophysical data. The traditional approach to data management in the astrophysical field is not able to keep up with the increasing size of the data gathered by modern detectors. An essential role in the astrophysical research will be assumed by automatic tools for information extraction from large datasets, i.e. data mining techniques, such as clustering and classification algorithms. This asks for an approach to data management based on data warehousing, emphasizing the efficiency and simplicity of data access; efficiency is obtained using multidimensional access methods and simplicity is achieved by properly handling metadata. Clustering and classification techniques, on large datasets, pose additional requirements: computational and memory scalability with respect to the data size, interpretability and objectivity of clustering or classification results. In this study we address some possible ...
2003-01-01
Energy Technology Data Exchange (ETDEWEB)
The Department of Energy (DOE) policy requires that all DOE activities be conducted in a manner that protects the safety of the public and provides a safe and healthful workplace for employees. DOE has also prescribed that all personnel be protected in any explosives operation undertaken. The level of safety provided shall be at least equivalent to that of the best industrial practice. The risk of death or serious injury shall be limited to the lowest practicable minimum. DOE and contractors shall continually review their explosives operations with the aim of achieving further refinements and improvements in safety practices and protective features. This manual describes the Department's explosive safety requirements applicable to operations involving the development, testing, handling, and processing of explosives or assemblies containing explosives. It is intended to reflect the state-of-the-art in explosives safety. In addition, it is essential that ...
1991-10-01
Crude oil and finished fuel storage stability: An annotated review
Energy Technology Data Exchange (ETDEWEB)
A state-of-the-art review and assessment of storage effects on crude oil and product quality was undertaken through a literature search by computer accessing several data base sources. Pertinent citations from that literature search are tabulated for the years 1980 to the present. This 1990 revision supplements earlier reviews by Brinkman and others which covered stability publications through 1979 and an update in 1983 by Goetzinger and others that covered the period 1952--1982. For purposes of organization, citations are listed in the current revision chronologically starting with the earliest 1980 publications. The citations have also been divided according to primary subject matter. Consequently 11 sections appear including: alternate fuels, gasoline, distillate fuel, jet fuel, residual fuel, crude oil, biodegradation, analyses, reaction mechanisms, containment, and handling and storage. Each section contains a brief narrative followed by all the citations for ...
1991-01-01
Contribution to 3D-operational geodesy. Pt. 3
Energy Technology Data Exchange (ETDEWEB)
Whereas in part 1 and 2 the detailed observation equations of terrestrial type for an integrated geodetic model are presented this paper will outline how the theory is transferred in an operational program. The main lines of functions of the FORTRAN IV program are discussed. Since the input specifications as well as the data requirements are described in detail and illustrated by example of input and output part 3 can serve as an user-guide for OPERA. OPERA is an acronym for operational adjustment. Besides the integrated determination of 3D-geocentric coordinates and the gravity disturbing potential the program can handle all cases of traditional geodesy (in total 13 variants of solution are provided) equivalent also with adjustments in ellipsoidal coordinates B, L or H, as well as constrained adjustments, pure prediction of the gravity disturbing field, etc.
1983-01-01
Energy Technology Data Exchange (ETDEWEB)
The present emphasis on inherent safety for LMR designs has resulted in a need to represent the various reactivity feedback mechanisms as accurately as possible. The dominant negative reactivity feedback has been found to result from radial expansion of the core for most postulated ATWS events. For this reason, a more detailed model for calculating the reactivity feedback from radial core expansion has been recently developed for use with the SASSYS/SAS4A Code System. The purpose of this summary is to present an extension to the model so that it is more suitable for handling a core restraint design as used in FFTF, and to compare the SASSYS/SAS4A results using this model to the empirical correlation presently being used to account for radial core expansion reactivity feedback to FFTF.
1987-01-01
Coal development potential in Pakistan
Energy Technology Data Exchange (ETDEWEB)
A total of 48 papers were presented, and covered the following topics: the current situation in Pakistan with respect to development and utilization of coal resources; the policies that have been responsible for the development and utilization of coal resources in Pakistan; coal development and utilization in other developing nations e.g. Indonesia, Greece, Philippines, China, Thailand and Haiti; and technological developments in coal exploration; extraction, handling, transport and utilization which could accelerate future development of Pakistan's coal resources. Specific subjects covered include the use of coal in the cement industry of Pakistan; the production of briquettes for domestic use, development and training of personnel for the coal industry; and sources of finance for coal development projects. Particular emphasis is given throughout the conference to the Lakhra coal mine/power plant project which aims to develop and effectively utilize the ...
1986-01-01
Characterization of physically vapor deposited AF2400 thin films
Energy Technology Data Exchange (ETDEWEB)
Anti-reflective coatings made with Teflon AF2400 had the highest damage thresholds recorded for physical vapor deposited coatings at the Lawrence Livermore National Laboratory damage facility. Physical vapor deposited layers of Teflon AF2400, a perfluorinated amorphous polymer, maintained the bulk optical properties of a high transmittance from 200 nm to 1600 nm, and a low refractive index. In addition, the refractive index can be intentionally reduced by control of two common deposition parameters, deposition rate and substrate temperature. Scanning electron microscopy and nuclear magnetic resonance observations indicated that morphological changes caused the variations in the refractive index rather than compositional changes. The coatings adhered to fused silica and silicon wafers under normal laboratory handling conditions.
1993-11-01
Body size and predatory performance in wolves: is bigger better?
British Library Electronic Table of Contents (United Kingdom)
Summary Large body size hinders locomotor performance in ways that may lead to trade-offs in predator foraging ability that limit the net predatory benefit of larger size. For example, size-related improvements in handling prey may come at the expense of pursuing prey and thus negate any enhancement in overall predatory performance due to increasing size. This hypothesis was tested with longitudinal data from repeated observations of 94 individually known wolves (Canis lupus) hunting elk (Cervus elaphus) in Yellowstone National Park, USA. Wolf size was estimated from an individually based sex-specific growth model derived from body mass measurements of 304 wolves. Larger size granted individual wolves a net predatory advantage despite substantial variation in its effect on the performance ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Kawasaki Steel started the construction of an automatic steel strip coil transportation system in the 1980's. Presently, most of the in-plant transportation of hot-rolled or cold-rolled coils are automated. For establishing the automatic transportation, there were developed various technologies, such as, the optimum handling technology using artificial intelligence, the technology of preventing additional piling of coils on existing coils by using an ultrasonic wave and a laser beam. Through the improvements of these technologies, a full-automated transportation system has been achieved and the system has contributed substantially toward product quality assurance and cost reduction. This paper gives the changes in the automation technology of coil transportation in the automation of No. 3 finishing hot rolling mill, now having the latest automatic system, in Chiba Works. (author)
1999-12-01
Energy Technology Data Exchange (ETDEWEB)
The overall aim is to develope programme modules for a Danish integrated computer system for projecting buildings and to ensure that Danish programmes are compatible with international systems. The programmes to be integrated here were AutoCAD and SCRIBE-Models and the simulation programme tsbi3 for the calculation of indoor climate conditions, power demand and energy consumption in buildings. For the calculation of humidity and temperature conditions in constructions a certain amount of integration is carried out with the MATCH programme (Moisture And Temperature calculations for Constructions of Hygroscopic materials). The activities embodied in the pilot projects are described in this working report in addition to individual computer programmes and prototypes, and examples and diagrams are presented. The programmes described deal with handling design elements in relation to AutoCAD designs, and the formatting of a building`s data from AutoCAD to tsbi3 format. ...
1993-03-01
International Nuclear Information System (INIS)
In the analysis of power systems security, recently a new concern related to possible malicious attacks caught much attention. Coordination among different transmission system operators (TSO) in an interconnected power system to counteract such attacks has become an important problem. This paper presents a general framework for describing the physical, cyber and decision-making aspects of the problem and their interrelations; within this framework, an analytic tool for the assessment of information impacts in handling on-line security after a malicious attack is proposed and discussed. The model is based on the socially rational multi-agent systems and the equilibrium of a fictitious play is considered to analyze the impacts of various levels of information available to the interconnected system operators on the outcomes of the decision-making process under attack. A 34-buses test system, with 3 systems interconnected by tie-lines, is presented to illustrate the ...
2009-06-01
Assessment and control of fetal exposure
Energy Technology Data Exchange (ETDEWEB)
The assessment and control of fetal exposure to radiation in the workplace is an issue that is complicated by both biological and political/social ramifications. As a result of the dramatic increase in the number of women employed as radiation workers during the past 10 years, many facilities using radioactive materials have instituted fetal protection programs with special requirements for female radiation workers. It is necessary, however, to ensure that any fetal protection program be developed in such a way as to be nondiscriminatory. A study has been initiated whose purpose is to balance the political/social and the biological ramifications associated with occupational protection of the developing embryo/fetus. Several considerations are involved in properly balancing these factors. These considerations include appropriate methods of declaring the pregnancy, training workers, controlling the dose to the embryo/fetus, measuring and calculating the dose to the embryo/fetus, and ...
1991-10-01
Annual report of JMTR. FY1997 (April 1, 1997 - March 31, 1998)
Energy Technology Data Exchange (ETDEWEB)
During FY1997, the JMTR was operated for 3 complete cycles (120th, 121st and 122nd cycles) and was utilized for the research and development programs on the technology of LWRs and fusion reactor, as well as for fundamental research of fuels and materials, and for radioisotope productions. The improvement of evaluation technique in a local neutron spectrum for irradiation utilization and development of capsule having the vertical migration, the reinstrumentation and loading mechanism have been carried out. Development of a new oxygen potential sensor for oxide fuel pellets has been done as an elemental technology of irradiation for high burn-up fuels. As for post irradiation examination, the techniques for measuring of crack length using an alternating current potential drop method and machining of miniaturized specimen by the remote handling have been developed. A research on the blanket materials and components for thermonuclear fusion reactor were also ...
1999-03-01
Analysis of in-situ fracture of oil sand formations by explosives
Energy Technology Data Exchange (ETDEWEB)
An analytical model is proposed for the design and simulation of in-situ fracture of deep oil sand formations. This model is based on the finite element variational principle in conjunction with special empirical modules to characterize in-situ oil sands behavior. A computer code by the name of SANFRAC was developed to handle the dynamic fracture of formations induced by explosives. Simulation of hydraulic fracture processes can be treated by the same code as special cases using the quasi-static analysis. Numerical case studies by the SANFRAC code indicate that extensive horizontal fracture can be achieved by dynamic loads with proper fracture starters configured at the injection well. The unique advantage of the dynamic fracturing technique over the hydraulic fracture methods is also demonstrated by these studies.
1987-03-01
Energy Technology Data Exchange (ETDEWEB)
A robust adaptive Power System Stabilizer algorithm using a Generalized Multivariable Pole Shifting (GMPS) technique is presented in this paper. The algorithm handles systems with equal or unequal numbers of inputs and outputs, therefore both shaft speed as well as the generator power are used to derive the stabilizing control. The technique also provides a simple scheme of on-line self-searching pole shifting factor to meet the excitation control limits. The application of the proposed stabilizer to a simulated generator excitation control under a wide range of operating and disturbance conditions demonstrates that the new control strategy is superior to conventional Power System Stabilizer (PSS) and the widely accepted Minimum Variance Self-Tuning Controller (MVSTC).
1992-08-01
Abstracts of 5. International conference 'Nuclear and Radiation Physics'
International Nuclear Information System (INIS)
The 5-th International conference 'Nuclear and Radiation Physics' was held in Almaty (Kazakhstan) 26-29 September 2005. Besides basic problems of nuclear and solid state physics the conference paid considerable attention to applied topics important for industry and science in Kazakhstan; they include fuel and construction materials for nuclear power production, new technologies and materials for their production, materials for hydrogen power production, handling and utilization of radioactive waste, analytical methods for combating with illicit trafficking of nuclear and radioactive materials, technologies for reduction and assessment of environmental risk from radiation-hazardous materials and sites, production and application of isotopes, application of nuclear technologies in medicine and industry. On the conference more than 300 papers were presented by participants from 20 countries.
2005-09-26
ANAPPRES: An expert system for interference well-test analysis
Energy Technology Data Exchange (ETDEWEB)
We present ANAPPRES V1.0, the first version of a computerized expert system capable of analyzing constant- and variable-flowrate interference tests, in which there is one active well and an arbitrary number of observation wells, in liquid-saturated homogeneous reservoirs. ANAPPRES successfully couples mathematical models, optimization techniques, heuristic knowledge and computerized graphics, a combination not often found in published expert systems. Its main advantages are that it is user friendly, requires essentially no experience on the part of the analyst, eliminates subjectivity associated with earlier techniques of analysis, can handle complex cases and large data sets, completes the analysis of even the most complex cases (including plotting the results) in one run, and is significantly faster than a human expert.
1988-01-01
A six-axes robot for deep water applications
Energy Technology Data Exchange (ETDEWEB)
The six-axes industrial robot MANUTEC r15 UW was modified to work underwater and successfully tested down to the simulated water depth of 1100 m. Next step in the program was to use this robot as a handling tool for inspection tasks at the welding seam of an underwater structure conducted with CCD-cameras and distance sensors. This was also to demonstrate the possibility to assist and later on to replace divers from this work. Additional research was focussed on the stiffness and rigidity of the robot during the precise guiding of tools and workpieces under current water conditions up to a flow velocity of 1.1 m/s. Present work is concentrated on the application of this subsea robot on a maintenance task at the Brazilian underwater template OCTOS-1000. For this experiments the robot is integrated in a large mock-up which simulates a quarter section of this template. (orig.)
1994-01-01
A patient specific electro-mechanical model of the heart
British Library Electronic Table of Contents (United Kingdom)
This paper presents a patient specific deformable heart model that involves the known electrical and mechanical properties of the cardiac cells and tissue. The whole heart model comprises ten Tusscher's ventricular and Nygren's atrial cell models, the anatomical and electrophysiological model descriptions of the atria (introduced by Harrild et al.) and ventricle (given by Winslow et al.), and the mechanical model of the periodical cardiac contraction and resting phenomena proposed by Moireau et al. During the propagation of the depolarization wave, the kinetic, compositional and rotational anisotropy is handled by the tissue, organ and torso model. The applied patient specific parameters were determined by an evolutionary computation method. An intensive parameter reduction was performed u...
2011-01-01
A neutrino-nucleon interaction generator for the FLUKA Monte Carlo code
Event generators that handle neutrino-nucleon interaction have been developed for the FLUKA code [1]. In earlier FLUKA versions only quasi-elastic (QEL) interactions were included, and the code relied on external event generators for the resonance (RES) and deep inelastic scattering (DIS). The new DIS+RES event generator is fully integrated in FLUKA and uses the same hadronization routines as those used for simulating hadron-nucleon interactions. Nuclear effects in neutrino-nucleus interactions are simulated within the same framework as in the FLUKA hadron-nucleus interaction model (PEANUT), thus profiting from its detailed physics modelling and longstanding benchmarking. The generators are available in the standard FLUKA distribution. They are presently under development and several improvements are planned to be implemented. The physics relevant to the neutrino-nucleon interactions and the results of comparisons with experimental data are discussed.
2010-01-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
